Read/Write Devices
5.6
SLG 42
Application area The SLG 42 is a middle-of-the-line read/write device. With its larger antenna, the SLG 42 generates a much larger field than the SLG 41, and a greater range can be achieved with the same data memories. In dynamic operation, larger amounts of data can be read from and written to the MDS.
See chapter 3.
4 .
Ordering data
Figure 5-23 SLG 42 read/write device
Table 5-14 Ordering data for SLG 42
Read/write device SLG 42 up to 70 mm (medium power)
SLG plug connector and stub lines
6GT2 001-0BA00
See chapter 3.10
Technical data Table 5-15 Technical data of SLG 42
Inductive interface to MDS
Data transmission speed
Read/write distance
SLG to MDS (max.)
Transmission frequency
Power
Data
Serial interface to ASM
19200 baud
70 mm (see field data table)
134 kHz
1.81 MHz
6-pin SLG plug connector in acc. w.
DIN 43651
19200 baud, RS 422
120 m
Transmission speed
Line length, ASM to SLG (max.) at 24 V DC
Supply voltage (via serial interface)
Nominal value
Permissible range
Current consumption
Idle/operation
MTBF
24 V DC
20 to 30 V DC
60 mA/180 mA
2 x 10 6
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8
.1
-7618 5-21
Read/Write Devices
Table 5-15 Technical data of SLG 42
Housing
Dimensions in mm (W x H x D)
Color
Material
Plug connection
Protection rating
Shock
Vibration
Mounting of SLG
Turning moment (at room temperature)
Ambient temperature
During operation
During transportation and storage
Weight (approx.)
Silicon free
75 x 40 x 75
Gray
Polyamide 12
DIN 43651
IP65
50 g
20 g
4 M5 screws
2 Nm
–25
°
to +70
°
C
–40
°
to +85
°
C
250 g
Yes
Field data The exact field data depend on the type of MDS used.
Table 5-16 Field data of SLG 42
Operating distance (S a
)
Limit distance (S g
)
Median deviation (L)
0 to 55 mm
70 mm
Depends on MDS
Minimum distance from SLG to SLG (D) > 800 mm
FCC information
Made in Germany
SIEMENS MOBY I SLG 42
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES .
OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE
RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE
UNDESIRED OPERATION.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
5-22
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8
.1
-7618
Read/Write Devices
Transmission window
Length of transmission window (L)
Transmission
ÏÏÏÏ ÏÏÏÏ window at operating distance
ÏÏÏÏ ÎÎ ÏÏÏÏ ÎÎ
M M
ÏÏÏÏ ÎÎ ÏÏÏÏ ÎÎ
ÏÏÏÏ ÎÎ ÏÏÏÏ ÎÎ
Figure 5-24 Transmission window of SLG 42
Metal-free space
ÏÏÏÏÏÏÏ a a
ÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏ a = 30 mm
Metal-free space with flush installation
ÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏ a
ÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏ
Figure 5-25 Metal-free space for SLG 42
Definition of distance D
D
SLG 42 SLG 42
D
SLG 42
Figure 5-26 Distance D: SLG 42
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8
.1
-7618 5-23
Read/Write Devices
Dimensions
(in mm)
6
40
75
65 75
5
5
5.5
25
49
Figure 5-27 Dimensional diagram of SLG 42
75
5-24
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8
.1
-7618