 Owner’s Manual
Storm DP Dehumidifier
| | (110-120V/60Hz, 220-240V/60Hz,dual-voltage)
[ | (110-120V/60Hz,single-voltage)
lb.
Listed
Intertek
ALORAIR SOLUTIONS INC.
Add: 2048E. Francis St Ontario CA 91761
Tel: 1-888-990-7469
Web: www.alorair.com
TABLE OF CONTENTS
Overview 3
Features 4
Specifications 4
Operation Notes Guidelines 5
Operation 7
Troubleshooting 12
Maintenance 13
Warranty 15
À waRNING
Please read and understand these warnings and instructions before using the machine.
Do not operate this device with the case opened or canceled.
À waRNING
Do not adjust or correct the machine in any way. Only use and replace parts authorized by
ALORAIR products. Modify or use approved parts.
It may cause danger or damage the machine, and the warranty will become invalid. You should
contact your dealer for assistance in this regard.
À мАвммс
(2) 1. Make sure to unplug the power plug before servicing.
2. Risk of electric shock
Make sure the power cord is properly grounded.
Check that the power cord is not damaged. If the plug is damaged, do not use the
E
Before opening the machine cover, make sure to unplug the power cord.
machine.
3. Be careful that moving parts can injure your hands. Make sure the power plug
has been unplugged before servicing.
4. The surface of the device may be hot. Allow the equipment to cool before
performing maintenance procedures.
OVERVIEW
Storm DP Dehumidifier has an extremely high water-repellent capacity, which makes the
machine an authorized machine to meet recovery needs. The flexible installation makes it ideal
for almost all applications. It is the best choice for all urgent post-water injection repair tasks
(elimination of moisture and early prevention of mold growth). Its wide range of applications
include flooding and restoration, carpet cleaning, laundry, merchants, garages, etc... or
anywhere you need to extract moisture at a professional level.
New generation surface scratch resistance polyethylene shell 25% than the previous
generation. The self-developed rotating shell design is easy to maintain and beyond
imagination. Telescopic handles and rubber tires are stacked together for easy transportation.
Under the condition of unchanged performance, the volume of the whole machine is 40%
smaller. Simplified user controls include a large LCD display and APP control. It can control the
dehumidifier at home anytime and anywhere, plus the built-in pump to pump water through the
dehumidifier more intelligently.
FEATURES
Smart Wi-Fi & APP control
Easy clean — shell can be opened to access all components
Easy to store wires and hoses
Built-in Condensate Pump
Environmental R410A Refrigerant
Sturdy handle-Large Diameter Wheels
Microchannel Cold a Heat Exchanger
Rotational Molded Body
Superior Stacking
Rotary Compressor
Ducting Options
Water-Full Protection
Automatic Humidistat Control
Quick Connection to Cable/Hose
Memory Starting
MERV-8 Filter
Low Temperature
SPECIFICATIONS
Power(dual-voltage):110-120V/60Hz,6.1A,220-240/60Hz,2.8A
Power(single-voltage):110-120V/60Hz,6.1A
Size For: Up to 1,300 sq. ft
Filter: MERV - 8 Filter
Airflow: 210 CFM, 350 CMH
Sound Pressure Level: < 58 dBA
Refrigerant: R410A
Wheel: 2 Wheels
Draining: Condensate Pump
Functioning Temperature Range: 35.6~100.4 °F
Functioning Humidity Range: 25~80%
Water Removal (AHAM): 50 PPD@80 °F-60%
Weight(dual-voltage):70.5 lbs
Weight(single-voltage):57.3 lbs
UnitDim(LxWxH): 14.9"X 14.6" X 23.1"
OPERATION NOTES GUIDELINES
The unit should be operated stored and transported on stable surfaces.For efficiency purposes,
the windows and the doors should be closed avoid placing the unit in a place where the air
outlet and inlet are blocked.
Drain Hose Notes
It comes with a drain line connection that is easily plugged in the unit .
The drain line may be directed into the drain or the sink .
For proper drainage, uncoil the hose before you deploy it to use.
The end of the hose should never be placed at the height of 15 feet.
Always ensure that the drain hose is not blocked before you embark on using it.
Transportation Notes
During transportation, you must secure the dehumidifier using elastic bands.
If the unit is transported vertically, let it stand in a normal position for not less than 30 minutes
before using it.
How it works
The dehumidifier uses an integral humidistat in monitoring the conditioned space. As soon as
the conditions get beyond the desired level, the air is energized. The compressor will then push
it across the evaporator coils. The coil is cooler than the dew point. So the water vapor will be
forced to condensate into liquid. The cool air will then be reheated before it is distributed into
the room.
Storm DP Dehumidifier
Front View
Filter
Handle
Water Pipe Power
> Cord Storage
Air Intlet Grille |
Wheel
Back View
у
$ =
ae iM N
we
VIS
MER |
$ En 2 ) y
“el AL,
АХ
A“
. р
Power Cord Plug
[8
BY, D O 0 age
(Only available for dual-voltage dehumidifier)
OPERATION
s
SS) 70° 60% 93%»
In
(CRE 90" 50% 700»
Out
Set
020 JOB HRS 050 LIFEHRS
POWER PURGE MENU SET
©
Press the POWER button to turn the dehumidifier ON and OFF.
POWER
Lt Press the PURGE button to purge the machine.
PURGE
== Press the MENU button to advance to the next screen or to enter a value.
MENU
Y)
Press the SET button to scroll through available values.
OPERATION NOTES GUIDELINES
1. When the unit is plugged in you will see the AlorAir LOGO.
__ALORAIR _
=a
2. The display will inform the machine is in shutdown mode,
press the “Power button” to turn on.
UNIT OFF
Press (1) to start
a 3. When the machine is in dehumidification mode, the display
=») 70% 60% 93.ь will show:
In
(S= 90" 50% 70.»
Out
020 JOBHRS 050 LIFE HRS
In: Temperature, Humidity, GPP of the current inlet. GPP= Grains per pound
(GR/LB)
Out: Temperature, Humidity, GPP of the current outlet. GPP= Grains per pound
(GR/LB)
Set [40% | Set: The humidity value currently Set (the machine will stand by after the
o
humidity reaches the Set value)
020 JOB HRS 050 LIFE HRS Job hours and Life hours display.
4.1 Press the MENU button to enter the submenu. Device
name displayed on the screen. Go to the APP to change only
applicable to an app-controlled dehumidifier. Press the MENU
button to confirm selection and advance to the next screen.
Go to the app to change
4.2 Display the working hours of this time. Press the MENU
JOB HOURS button to confirm selection and advance to the next screen.
9999
Hold > to Reset
COIL TEMP
WIFI HOTSPOT
of
Press >> to change
POWER DOWN
System Shutdown
In 10:59
POWER DOWN TIME
Press > to change
TEMP UNITS
<
Press >» to change
4.3 The screen displays the Coil temp. Press the MENU button
to confirm selection and advance to the next screen.
4.4 Wifi Hotspot: Factory setting is "OFF", press “set button” to
enable Wifi hotspot and switch ON/OFF. The device can
transmit data and receive APP commands. The icon flickers
when connected to the main interface. After a successful
connection, the icon displays normally. Only applicable to
APP-controlled dehumidifier. Press the MENU button to
confirm selection and advance to the next screen.
4.5 Press the “power button” to turn off the dehumidifier, the
dehumidifier will go through a shutdown cycle.
The shutdown cycle can be adjusted according to "Settings",
and the shutdown cycle can be adjusted from 3 minutes to 20
minutes to better drain the water.
4.6 Press the Set button to toggle the temperature units
between °F and °C. Press the MENU button to confirm
selection and advance to the next screen.
MOISTURE CONTENT
UNITS
ке
Press >) to change
HUMIDISTAT
SETPOINT
Press >> to change
“CO” indicates continuous mode
1 60% 93»
In
[A= 80" 60% 93,
Out
000 LIFE HRS
666
000 JOB HRS
DEFROSTING
Defrost Shutdown
In 06:00
RESTARTING
Compressor ready
In 03:00
4.7 Press the “Set button” to switch GPP units between gr/Ib.
or gr/kg. Press the “MENU button” to confirm the selection
and advance to the next screen. GPP= Grains per pound
(GR/LB)
4.8 Press the “Set button” to adjust the set point RH% in 5%
increments ranging from 25 to 80% RH. and then loop back to
CO. Adjust to CO mode, dehumidifier always running. Press
the “MENU button” to confirm selection and advance to the
next screen.
4.9 The display prompts the user that the defrost cycle is in
progress.
The defrosting status is displayed on the main interface as a
flashing icon until the defrosting ends and the defrosting lamp
disappears. In the meantime, please wait patiently for the
machine to finish frosting.
5.0 The compressor is in a protective condition. During this
period, please be patient and wait for the countdown to end.
The dehumidifier will automatically turn on after the
countdown.
-10-
PURGING SYSTEM
starting 28 second
purge cycle
=%| 807
In
(АЕ 80"
Out
Ar
000 JOB HRS
60” 93%
60% : & 277
000 LIFE HRS
5.1 When the purge button is pressed the display will tell the
user on the dashboard that the pump is draining and display a
30-second countdown timer. Until the machine finishes
draining, the display will also prompt the user on the
dashboard that the machine is draining automatically, and
display a 30-second countdown.
-11-
TROUBLESHOOTING
Symptom Cause Solution
| inte C | Check and ensure that the two ends of the
nappropriate Connection
A blank Display PRIOR | power code are properly plugged in
Power Outage
Try to have the power reset
The air is not flowing
A dirty Filter
The filter should be cleaned
A blocked air outlet and
inlet
Remove the blockage
Error Code: E1
Communication or humidity
sensor error
Ensure the sensor wire is properly connected at
the two ends. If no issue is visible, it shows that
the sensor is faulty.
Error Code: E4
Problem with Pump
Verify that the pump is properly
Installed and functioning. If so,
unplug the unit for two minutes,
Then restart.
Error Code: LO
It comes forth when the
temperature in the room
falls below 33° F
The temperature in the room must be increased
and should be above 33°F. If an error is
displayed, you may need to check the sensor.
Error Code: HI
It occurs when the room
temperature is above
105°F
Reduce the temperature to below 105°F. But
if the error is still being displayed, check the
sensor.
E5 Error Code
Leaking of the Refrigerant
Get help from installation assistant.
Wi-Fi connection successful.
Connection to server failed.
Hotspot direct successful icon.
-12-
MAINTENANCE
1. Remove the two screws on the mold cover.
2. Rotating shell.
3. Tilt the machine at a certain angle to remove the casing from the machine.
4. Clean the inside of the machine.Soap insolvents should not be used.
-13-
Cleaning the Machine Body
Use a soft, damp cloth to clean the exterior parts of the unit. Do not use any soap or solvents.
Procedure for filter maintenance
The dust and obstacles on the filter should be removed regularly. You may need to clean and
replace the filter.
Step:
1.Unplug the unit.
2.Remove the filter by sliding it upward from the bottom by
hand to remove it.
3.Check for dirt and build-up.
4.For MERV-8 or Pre-filter, wash it in warm water or
vacuum it. Do not use soap or cleaners. Also, shake it
gently and ensure the filters are dry before reinserting it.
-14-
Limited Warranty
This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the
original purchaser that this ALORAIR product is free from manufacturing defects in material
or workmanship for the limited warranty period of:
Six (6) Month parts and labor. This includes the shipments charges for replacement parts
or unit.
One (1) year parts and labor. This does not include the shipment charge to send the
defective product back to be repaired or replaced.
Three (3) years parts and labor on Refrigeration System ONLY (Compressor,
Condenser, and evaporator). Transportation cost, not included.
Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and
evaporator). Transportation cost, not included.
This limited warranty is valid only on products purchased from the manufacturer or
ALORAIR authorized dealer and operated, installed, and maintained according to the
instructions included in this user guide or furnished with the product. Alorair Solutions Inc
will not provide in-home service during or after the warranty period. You may be responsible
for the shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact ALORAIR at 888-990-7469 or
[email protected]. A proof of purchase or order number is required to receive warranty
service. During the applicable warranty period, a product will be repaired or replaced at the
sole option of ALORAIR.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship
encountered in normal household, commercial or noncommercial use of this product and
shall not cover the following:
‚ Damage occurs in uses for which this product was not intended for.
e Damage caused by unauthorized modification or alteration of the product.
+ Cosmetic damage including scratches, dents, chips, and other damage to the
product's finishes.
+ Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other
acts of nature.
e Damage caused by incorrect electrical line current, voltage, fluctuations, and
surges.
¢ Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited
warranty.
-15-