Advertisement
Advertisement
INSTALLATION
MANUAL ANNEX
OF STANDARD
SOLAR MODULE
For professional use only
ANNEX A: ALTERNATIvE MOUNTINg METhODS
MOUNTINg METhOD A: CLAMpINg
MOUNTINg METhOD B: INSERTION SySTEMS
MOUNTINg METhOD C: CENTER MOUNTINg METhOD
|10 wITh ThIRD pARTy TRACkER
ANNEX B: ALTERNATIvE gROUNDINg METhODS |11
ANNEX C : MEChANICAL AND ELECTRICAL RATINgS |13
ANNEX D: MODULE CLEANINg gUIDELINES |16
AMENDED EDITIONS AND DATES |17
|3
|3
|8
EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
ANNEX A: ALTERNATIvE MOUNTINg METhODS
All the basic requirements of the main installation manual should apply to the alternative mounting methods, unless otherwise speciied.
Design load and safety factors will be determined by the racking suppliers or professional engineers. For detailed information, please follow local structural code or contact your professional structural engineer.
MOUNTINg METhOD A
CLAMpINg
· The mounting method has been qualiied by
Canadian Solar Inc. and certiied by VDE and CSA.
Do not bend the module frame
Do not touch or cast shadows on the front glass
Do not damage the surface of the frame
Ensure the clamps overlap the module frame by at least 5 mm (0.2 in)
Ensure the clamps overlap length is at least 40 mm (1.57 in)
Min. 3 mm thickness
· Top or bottom clamping methods will vary and are dependent on the mounting structures. Please follow the mounting guidelines recommended by the mounting system supplier.
· Each module must be securely fastened at a minimum of four points on two opposite sides.
The clamps should be positioned according to the authorized position ranges deined in table
A. Install and tighten the module clamps to the mounting rails using the torque stated by the mounting hardware manufacturer. M8X1.25-
Grade8.8 bolt and nut are used for this clamping method. Tightening torques should be within
17~23 Nm (12.5~17.0 ft-lbs) for M8 coarse thread bolts, depending on the bolt class. For the bolt grade, the technical guideline from the fastener suppliers need to be followed.Different recommendations from speciic clamping hardware suppliers should prevail. System designer and installer are responsible for load calculations and for proper design of support structure.
· Canadian Solar Inc.’s warranty may be void in cases where improper clamps or unsuitable installation methods are found. When installing inter-modules or end-type clamps, please take the following measures into account:
Min. 5 mm overlap
Min. overlap length
40 mm
· Clamp material should be anodized aluminum alloy or stainless steel.
· Clamp positions are of crucial importance for the reliability of the installation. The clamp centerlines must only be positioned within the ranges indicated in table A, depending on the coniguration and load.
· For conigurations where the mounting rails run parallel to the frame, precautions should be taken to ensure the bottom lange of the module frame overlaps the rail by 15 mm (0.59 in) or more.
Min. 15 mm overlap width www.canadiansolar.com
4 |
Table A
CS6X-xxxp and CS6X-xxxM
A1 A1
A1 A1
Use four clamps on the long side. Mounting rails run perpendicularly to the long side frame.
A1 range = (340 – 550) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A1 range = (410 – 490) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A2 A2
A2 A2
Use four clamps on the short side. Mounting rails run parallel to the long side frame.
A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 1800 Pa
Downforce load ≤ 2400 Pa
A1 A1
A1 A1
Use four clamps on the long side. Mounting rails run parallel to the long side frame.
A1 range = (410 – 490) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A2 A2
A2 A2
Use four clamps on the short side and two clamps on the long side. An additional support bar should be placed below the center of the module
A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
CS6U-xxxp and CS6U-xxxM
A1 A1
A1 A1
Use four clamps on the long side. Mounting rails run parallel to the long side frame.
A1 range = (410 – 490) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A1 A1
A2 A2
A2 A2
Use four clamps on the short side and two clamps on the long side. An additional support bar should be placed below the center of the module.
A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
|
5
A1 A1
Use four clamps on the long side. Mounting rails run perpendicularly to the long side frame.
A1 range = (340 – 550) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A1 range = (410 – 490) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa www.canadiansolar.com
6 |
CS6k-xxxp, CS6k-xxxM, CS6p-xxxp and CS6p-xxxM
A1 A1
A2
A1 A1
Use four clamps on the long side. Mounting rails run perpendicularly to the long side frame.
A1 range = (0 – 239) mm
Maximum Load:
Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa
A1 range = (240 – 550) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A1 range = (240 – 330) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A2 A2
A2
A2 A2
Use four clamps on the short side. Mounting rails run parallel to the long side frame
A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A2
Use four clamps on the short side.
A2 range = (0 – 250) mm
Maximum Load:
Uplift load ≤ 2000 Pa
Downforce load< 2000 Pa
A2
A2 A2
A2 A2
Use four clamps on the short side and two clamps on the long side. An additional support bar should be placed below the center of the module.
A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A1 A1
EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
A1 A1
Use four clamps on the long side. Mounting rails run parallel to the long side frame
A1 range = (240 – 3300) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa
CS6A-xxxp and CS6A-xxxM
A1 A1
A2
A2
Use four clamps on the short side. Mounting rails run parallel to the long side frame
A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A2
A2
A2
A1 A1
Use four clamps on the long side. Mounting rails run perpendicularly to the long side frame.
A1 range = (0 – 219) mm
Maximum Load:
Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa
A1 range = (220 – 440) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A1 range = (270 – 330) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A2
A2
Use four clamps on the short side.
A2 range = (0 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A1 A1
A2
A2 A2
A2 A2
Use four clamps on the short side and two clamps on the long side. An additional support bar should be placed below the center of the module.
A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
|
7
A1 A1
Use four clamps on the long side. Mounting rails run parallel to the long side frame.
A1 range = (270 – 330) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa www.canadiansolar.com
8 |
CS6v-xxxp and CS6v-xxxM
A1 A1
A2
A2
Use four clamps on the short side. Mounting rails run parallel to the long side frame
A2 range=(170 – 210) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A2
A2
A1 A1
Use four clamps on the long side. Mounting rails run perpendicularly to the long side frame.
A1 range = (0 – 239) mm
Maximum Load: Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa
A1 range = (240 – 550) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A1 range = (240 – 330) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A2 A2
A2
Use four clamps on the short side.
A2 range = (0 – 210) mm
Maximum Load: Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa
A2
A2 A2
A2
Use four clamps on the short side and two clamps on the long side. An additional support bar should be placed below the center of the module.
A2 range = (200 – 250) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A1 A1
A2
EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
A1 A1
Use four clamps on the long side. Mounting rails run paralel to the long side frame.
A1 range = (240 – 330) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa
|
9
CS6k- xxxMS
A1 A1
A1 A1
Use four clamps on the long side. Mounting rails run perpendicularly to the long side frame.
A1 range = (310 – 350) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
MOUNTINg METhOD B:
INSERTION SySTEMS
· The mounting method has been qualified by
Canadian Solar Inc. and certified by VDE and CSA.
· Insertion methods can vary and depend on the mounting structures. The installer needs to follow the mounting guidelines recommended by the mounting system supplier. Each module must be securely maintained through all its length on two opposite sides. Install and tighten the insertion profiles to the support structure using the hardware and instructions provided by the mounting system manufacturer. System designer and installer are solely responsible for load calculations and for the proper design of support structure.
· Canadian Solar Inc. warranty may be void in cases where improper insertion systems or unsuitable installation methods are found. When installing insertion profiles, please take the following measures into account:
1.Do not bend the module frame
2.Do not touch the front glass or cast shadow onto it
3.Do not damage the surface of the frame
4.Ensure that the insertion profiles overlap the module frame by at least 10 mm (0.39 in).
5.Ensure that the module frame (C-shape) overlaps the insertion profiles by at least 15 mm (0.59 in).
6.Ensure insertion profile thickness and tolerances suit module thickness of 40 mm (1.57 in) modules).
www.canadiansolar.com
10 |
CS6X-xxxp, CS6X-xxxM, CS6U-xxxp and CS6U-xxxM
Use two insertion proiles running parallel to the long side frame.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
Use two insertion proiles running parallel to the short side frame. An additional support bar should be placed below the module. Use two clamps on the support bar.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
CS6k-xxxp, CS6k-xxxM, CS6p-xxxp, CS6p-xxxM, CS6v-xxxp and CS6v-xxxM
Use two insertion proiles running parallel to the long side frame.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa
Use two insertion proiles running parallel to the short side frame.
Maximum Load:
Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa
Use two insertion proiles running parallel to the short side frame. An additional support bar should be placed below the module. Use two clamps on the support bar.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
CS6A-xxxp and CS6A-xxxM
Use two insertion proiles running parallel to the long side frame.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa
Use two insertion proiles running parallel to the short side frame.
Maximum Load:
Uplift load ≤2400 Pa
Downforce load ≤ 2400 Pa
|
11
Use two insertion proiles running parallel to the short side frame. An additional support bar should be placed below the module. Use two clamps on the support bar.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
MOUNTINg METhOD C:
CENTER MOUNTINg METhOD wITh ThIRD pARTy TRACkER
· Canadian Solar modules can be mounted with third
party trackers as described below. All the require-
ments of the main manual and related tracker
installation manual should apply to the tracker
installation method. For detailed installation
instructions, please refer to the related third party
installation manual.
· The mounting method has been qualiied by Canadian
Solar Inc. and certiied by VDE and CSA.
Mounting Rail www.canadiansolar.com
12 |
Module
Type
Compatible
Tracker
Mounting hardware
Maximum Load (pa)
Reference Manual
(version No.)
CS6P-xxxP
ATI DuraTrack™HZ
Tracking
System(V2.5)
12-inch length standard clamp
(V2.5)
Uplift load ≤ 1200 Pa
Downforce load ≤ 1200
Pa
DuraTrack™HZ Solar
Tracker Installation Guide
(November,2012, Rev. B-01)
CS6X-xxxP and
CS6P-xxxP
CS6X-xxxP
CS6U-xxxP and CS6UxxxM
ATI DuraTrack™HZ
Tracking
System(V2.5)
ATI DuraTrack™HZ
Tracking System(V3)
CS6X-xxxP
CS6U-xxxP and
CS6U-xxxM
CS6X-xxxP
NEXTracker SPT
NEXTracker SPT
NEXTracker SPT
12-inch length highclearance clamp
(V2.5)
Uplift load ≤ 2000 Pa
Downforce load ≤ 2400
Pa
DuraTrack™HZ Solar
Tracker Installation Guide
(November 2012, Rev. B-01)
Clamp Ear (V3)
4142 short module mounting rail
NEXTracker SPT2.1.1 mounting rail
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400
Pa
DuraTrack™HZ Solar Tracker
Installation Guide (March
2015, Rev. A-02)
Uplift load ≤ 1800 Pa
Downforce load ≤ 2400
Pa
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400
Pa
Nextracker SPT Installation
Manual For 72-Cell Framed
Modules (MKT0123 Rev04,
April 2015)
NEXTrackerSPT
2.1.1 Installation anual(PDM-000002 Revision:
A. August 2015)
4152 short module mounting rail
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400
Pa
Nextracker SPT Installation
Manual For 72-Cell Framed
Modules
(March 2015)
Please contact the tracker manufacturer and Canadian
Solar Inc.’s technical support department for details in regard to speciic projects.
ANNEX B: ALTERNATIvE gROUNDINg METhODS
· Canadian Solar modules can be grounded using third party grounding devices as described below.
The grounding methods are certified by CSA according to UL1703. All the basic requirements of the main installation manual should apply to the alternative grounding methods. For detailed grounding instructions, please refer to related third party installation manuals.
EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
|
13
Method Company
A
B
C
D
E
F g grounding hardware Compatible tracker Reference Manual (version No.)
Variety
UNIRAC Inc.
Schletter
GmbH
PanelClaw
Inc.
Array echnologies
Inc.
Lay-in-Lug + Star Washer
(UL2703&UL467 certiied)
UGC-1 grounding clips
Schletter Rapid2+
Grounding Clamps
Standard Claw (integrated grounding)
ATI SS CLIPS & WEEB-
ADC&WEEB-ADR
Variety
SolarMount® rails
Schletter Rapid2+
Related reference installation manual
Unirac Code-Compliant Installation
Manual (Pub 140130 -1cc)
Schletter Rapid2+ Clamp installation instructions
PanelClaw Grizzly
Bear® FR Gen II mounting system
Grizzly Bear® FR Gen II Installation
Manual (9910010 Rev A)
WEEB installation instructions for
ATI Duratrack HZ Solar racker(V2.5)
ATIDuraTrack HZ mounting system only (50018785 RevC) from Burndy
LLC & DuraTrack™HZ Solar Tracker
Installation Guide (June 2014, Rev.
B-02) from ATI
IronRidge
Inc.
Cosma
International grounding mid clamps
(integrated grounding)
WEEB-DPF grounding clips standard (XRS) and light (XRL) rails
Cosma/Magna top clamp mounting system
Standard (XRS) and Light (XRL)
Rails with Integrated Grounding
Installation Manual
(2013 Edition v1.13)
Ground Mount Racking Structure
Assembly Instructions
(V1.5_7196_CEC0022_02-21-2013) h
DYNORAXX
Inc.
DynoRaxx® DynoBond spring clips
-----
DynoRaxx® DynoBond Installation
Manual (publication no 090413)
I
J
K
L
M
N
O
P
Q
RBI Solar
Inc.
Quick Rack
PV Inc.
Cantsink
Mfg Inc.
Raised Zee purlin integrated with prepunched grounding holes
Clamp integrated with grounding pins
1/4" serrated lange bolt & serrated lange nut
RBI Solar Ground
Mount System Model
GM-I
Ground Mount System Model GM-I module Installation Manual
(14 April 2014, version 21)
Quick Rack Rail-Free
Mounting System
Brilliant Rack Ground
Mount System
Quick Rack Rail-Free Mounting
System for Composition/Asphalt
Shingle Roofs Installation Manual
(May 2014, Rev F)
Brilliant Rack Ground Mount
System Installation Manual
(Revision 12/05/2014)
Everest Solar
Systems, LLC
WEEB-KMC Clips
Crossrail 36, Crossrail
48 And Crossrail 80
Mounting Systems
WEEB Installation Instructions For
Everest Solar Crossrail 36, Crossrail
48 And Crossrail 80 Mounting
Systems Only (50015303 Rev H)
Unirac Inc. Mid clamp retention teeth SOLAR MOUNT (SM)
Solar Mount Installation Guide
(Revision PUB15MAR02)
Sunlink Inc.
Center Clamps & End
Clamps with pre-punched teeth
Ballasted Ground
Mount System and
Core Roof Mount
System
Assembly Instructions for Core RMS
(Rev 03-14-2014) and Assembly
Instructions for Ballasted GMS
(Rev 02/02/2014)
Roof Tech
Inc.
Bonding Plate
RT-[E] Mount E Mount
AIR
RT-[E] Mount E Mount AIR
Installation Manual (March 2015)
NEXTracker
Inc.
4111-8 Bobtail Collar and
4110-8 Bobtail Pin
BURNDY
LLC.
WEEB-UIR and WEEB-11.5
NEXTracker 120 Solar
Tracker.
RBI Solar
Groundmount
NEXTrackerSPT Installation Manual
(March 2015)
Weeb Installation Instructions; For
Rbi Solar Groundmount Only (104-
0404-000074-003) www.canadiansolar.com
14 |
ANNEX C: MEChANICAL AND ELECTRICAL RATINgS
Standard Test Conditions are: irradiance of 1 kW/m 2 ,
AM1.5 spectrum, and cell temperature of 25°C. The electrical characteristics are respectively within ±10% or [0; +5W] of the indicated values for Isc, Voc and
Pmax. Specifications are subject to change without notice.
CS6p-280M
CS6p-285M
CS6p-290M
CS6p-240p
CS6p-245p
CS6p-250p
CS6p-255p
CS6p-260p
CS6p-265p
CS6p-270p
CS6p-275p
CS6p-280p
CS6p-285p
CS5A-195M
CS5A-200M
CS5A-205M
CS5A-210M
CS6p-245M
CS6p-250M
CS6p-255M
CS6p-260M
CS6p-265 M
CS6p-270M
CS6p-275M
CS6A-195M
CS6A-200M
CS6A-205M
CS6A-210M
CS6A-215M
CS6A-220M
CS6A-205MS
CS6A-210MS
CS6A-215MS
CS6A-220MS
CS6A-225MS
Table 1: Mechanical And Electrical Ratings under STC
Module Type
Maximum power pmax <w>
Operating voltage vmp <v>
Operating current
Imp <A>
37.5
37.7
37.9
38.0
38.2
38.3
38.5
38.6
38.7
37.0
37.1
37.2
37.4
37.5
37.7
37.8
37.9
38.2
Open
Circuit voltage voc <v>
45
45.3
45.4
45.6
37.4
30.8
31.0
31.2
31.4
38.3
29.9
30.0
30.2
30.3
30.4
30.6
30.6
275.0
280.0
285.0
290.0
240.0
245.0
250.0
255.0
260.0
265.0
270.0
275.0
280.0
250.0
255.0
260.0
265.0
270.0
195.0
200.0
205.0
210.0
245.0
285.0
195.0
200.0
205.0
210.0
215.0
220.0
205.0
210.0
215.0
220.0
225.0
30.4
30.6
30.8
31.0
31.3
31.3
31.5
31.7
31.9
29.9
30.0
30.1
30.2
30.4
30.5
30.7
30.9
31.1
37
37.4
37.7
38.1
30.3
24.7
24.9
25.1
25.3
31.4
24.2
24.3
24.5
24.6
24.7
24.8
24.5
8.56
8.66
8.75
8.88
8.95
8.80
8.89
8.98
9.09
8.03
8.17
8.30
8.43
8.22
8.35
8.48
8.61
8.67
5.27
5.35
5.43
5.51
8.09
8.50
8.63
8.76
8.91
9.06
8.04
8.22
8.38
8.54
8.70
8.87
8.37
9.12
9.23
9.32
9.45
9.52
9.31
9.43
9.51
9.59
8.59
8.74
8.87
9.00
8.74
8.87
8.99
9.11
9.19
Short
Circuit
Current
Isc <A>
5.62
5.71
5.81
5.90
8.61
9.29
9.37
9.45
9.53
9.64
8.56
8.74
8.90
9.06
9.22
9.31
9.21
Max. Series
Fuse
Rating <A>
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
10.00
10.00
10.00
10.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
Overall
Dimension
<mm>
1595 x 801 x 40
1638 x 982 x 40
1638 x 982 x 40
1324 x 984 x 40 weight
<kg>
15.3
18.0
18.0
15.5
EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
|
15
Module Type
CS6A-230MS
CS6A-235MS
CS6A-240MS
CS6A-245MS
CS6A-195p
CS6A-200p
CS6A-205p
CS6A-210p
CS6A-215p
CS6A-220p
CS6X-290p
CS6X-295p
CS6X-300p
CS6X-305p
CS6X-310p
CS6X-315p
CS6X-320p
CS6X-325p
CS6X-330p
CS6X-335p
CS6X-340p
CS6X-345p
CS6X-350p
CS6v-200M
CS6v-205M
CS6v-210M
CS6v-215M
CS6v-220M
CS6v-225M
CS6v-230M
CS6v-235M
CS6v-240M
CS6v-245M
CS6v-210MS
CS6v-215MS
CS6v-220MS
CS6v-225MS
CS6v-230MS
CS6v-235MS
CS6v-240MS
CS6v-245MS
CS6v-250MS
CS6v-255MS
CS6vh-115MS
CS6vh-120MS
Maximum power pmax <w>
Operating voltage vmp <v>
Operating current
Imp <A>
350.0
200.0
205.0
210.0
215.0
220.0
225.0
230.0
235.0
240.0
245.0
210.0
215.0
220.0
225.0
230.0
235.0
240.0
245.0
250.0
255.0
115.0
120.0
305.0
310.0
315.0
320.0
325.0
330.0
335.0
340.0
345.0
230.0
235.0
240.0
245.0
195.0
200.0
205.0
210.0
215.0
220.0
290.0
295.0
300.0
25.7
26.0
26.1
26.4
26.7
27.0
25.4
25.6
25.8
26.0
38.1
25.2
25.3
25.4
25.5
26.2
26.4
26.6
26.8
27.0
27.2
13.1
13.3
36.3
36.4
36.6
36.8
37.0
37.2
37.4
37.6
37.8
25.5
25.7
25.9
26.1
24.0
24.1
24.2
24.3
24.5
24.6
35.9
36.0
36.1
8.56
8.67
8.81
8.91
9.00
9.09
8.27
8.40
8.53
8.66
9.21
7.95
8.11
8.27
8.43
8.78
8.91
9.03
9.15
9.26
9.38
8.78
9.03
8.41
8.52
8.61
8.69
8.78
8.88
8.96
9.05
9.13
9.02
9.14
9.27
9.39
8.13
8.30
8.47
8.63
8.78
8.95
8.08
8.19
8.30
31.6
31.8
31.9
32.1
32.2
32.4
31.5
31.7
31.9
32.1
46.2
31.1
31.2
31.3
31.5
32.3
32.5
32.7
32.9
33.1
33.3
16.2
16.4
30.4
44.4
44.5
44.6
44.8
44.9
45.1
45.3
45.5
45.6
45.8
45.9
46.0
Open
Circuit voltage voc <v>
31.6
31.8
32.0
32.2
29.6
29.8
29.9
30.0
30.2
Max. Series
Fuse
Rating <A>
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
Overall
Dimension
<mm>
1324 x 984 x 40
1954 × 982 × 40
1638 × 826 × 40
844 × 826 × 40
9.08
9.19
9.33
9.45
9.55
9.66
9.19
9.27
9.35
9.43
9.79
8.46
8.63
8.79
8.94
9.51
9.59
9.67
9.75
9.83
9.91
9.59
9.67
9.45
8.64
8.76
8.87
8.97
9.08
9.18
9.26
9.34
9.45
9.54
9.62
9.69
Short
Circuit
Current
Isc <A>
9.61
9.68
9.76
9.84
8.69
8.87
9.03
9.19
9.35
weight
<kg>
15.5
22.00 (3.2mm
Glass)
16.0
9.0
www.canadiansolar.com
16 |
Module Type
CS6vh-125MS
CS6v-190p
CS6v-195p
CS6v-200p
CS6v-205p
CS6v-210p
CS6v-215p
CS6v-220p
CS6v-225p
CS6v-230p
CS6v-235p
CS6v-220p
CS6v-225p
CS6v-230p
CS6v-235p
CS6k-240p
CS6k-245p
CS6k-250p
CS6k-255p
CS6k-260p
CS6k-265p
CS6k-270p
CS6k-275p
CS6k-280p
CS6k-285p
CS6k-250M
CS6k-255M
CS6k-260M
CS6k-265 M
CS6k-270M
CS6k-275M
CS6k-280M
CS6k-285M
CS6k-290M
CS6k-255MS
CS6k-260MS
CS6k-265MS
CS6k-270MS
CS6k-275MS
CS6k-280MS
CS6k-285MS
CS6k-290MS
CS6k-295MS
CS6k-300MS
CS6k-305MS
Maximum power pmax <w>
Operating voltage vmp <v>
Operating current
Imp <A>
275.0
280.0
285.0
250.0
255.0
260.0
265.0
270.0
275.0
280.0
285.0
290.0
255.0
260.0
265.0
270.0
275.0
280.0
285.0
290.0
295.0
300.0
305.0
230.0
235.0
240.0
245.0
250.0
255.0
260.0
265.0
270.0
125.0
190.0
195.0
200.0
205.0
210.0
215.0
220.0
225.0
230.0
235.0
220.0
225.0
30.7
30.9
31.1
31.3
31.5
31.7
31.9
30.7
30.9
31.1
31.0
31.3
31.4
30.4
30.5
31.3
31.5
31.7
31.9
32.1
32.3
32.5
32.7
25.9
26.1
29.9
30.0
30.1
30.2
30.4
30.6
30.8
13.5
24.6
24.8
24.9
25.0
25.1
25.3
25.5
25.7
25.9
26.1
25.5
25.7
8.48
8.61
8.67
8.80
8.89
8.98
9.09
8.31
8.42
8.53
8.88
8.95
9.06
8.22
8.35
8.63
8.74
8.84
8.94
9.05
9.14
9.24
9.33
8.90
8.99
8.03
8.17
8.30
8.43
8.56
8.66
8.75
9.26
7.73
7.87
8.03
8.19
8.35
8.51
8.64
8.75
8.90
8.99
8.64
8.75
37.8
37.9
38.2
38.3
38.5
38.6
38.7
37.9
38.1
38.3
38.0
38.2
38.3
37.5
37.7
38.5
38.7
38.9
39.1
39.3
39.5
39.7
39.9
31.7
31.8
31.4
31.6
31.7
31.8
37.0
37.1
37.2
37.4
37.5
37.7
37.9
30.8
30.9
31.1
31.2
31.4
31.6
Open
Circuit voltage voc <v>
16.6
30.6
30.7
8.99
9.11
9.19
9.31
9.43
9.51
9.59
9.11
9.19
9.27
9.45
9.52
9.64
8.74
8.87
9.35
9.43
9.51
9.59
9.67
9.75
9.83
9.91
9.47
9.58
9.21
9.32
9.47
9.58
8.59
8.74
8.87
9.00
9.12
9.23
9.32
8.59
8.76
8.92
9.07
9.21
9.32
Short
Circuit
Current
Isc <A>
9.75
8.28
8.44
Max. Series
Fuse
Rating <A>
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
Overall
Dimension
<mm>
1638 × 826 ×40
1650 x 992 x 40
1650 x 992 x 40 weight
<kg>
16.0
18.2
18.2
EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
|
17
Module Type
CS6U-290p
CS6U-295p
CS6U-300p
CS6U-305p
CS6U-310p
CS6U-315p
CS6U-320p
CS6U-325p
CS6U-330p
CS6U-335p
CS6U-340p
CS6U-345p
CS6U-350p
CS6U-290M
CS6U-295M
CS6U-300M
CS6U-305M
CS6U-310M
CS6U-315M
CS6U-320M
CS6U-325M
CS6U-330M
CS6U-335M
CS6U-340M
CS6U-345M
CS6U-350M
Maximum power pmax <w>
Operating voltage vmp <v>
Operating current
Imp <A>
290.0
295.0
300.0
305.0
310.0
315.0
320.0
325.0
330.0
335.0
340.0
345.0
350.0
290.0
295.0
300.0
305.0
310.0
315.0
320.0
325.0
330.0
335.0
340.0
345.0
350.0
36.9
37.2
37.4
37.5
37.8
37.9
18.1
38.3
36.3
36.4
36.5
36.6
36.7
35.9
36.0
36.1
36.3
36.4
36.6
36.8
37.0
37.2
37.4
37.6
37.8
38.1
8.53
8.61
8.69
8.8
8.87
8.97
9.06
9.14
8.00
8.11
8.22
8.33
8.44
8.08
8.19
8.30
8.41
8.52
8.61
8.69
8.78
8.88
8.96
9.05
9.13
9.21
45.8
45.9
46.0
46.2
44.7
44.9
45
45.2
45.3
44.8
44.9
45.1
45.3
45.5
45.6
Open
Circuit voltage voc <v>
44.4
44.5
44.6
45.5
45.6
45.8
45.9
46.1
46.2
46.4
46.6
Max. Series
Fuse
Rating <A>
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
9.54
9.62
9.69
9.79
8.51
8.63
8.74
8.84
8.95
8.97
9.08
9.18
9.26
9.34
9.45
Short
Circuit
Current
Isc <A>
8.64
8.76
8.87
9.04
9.13
9.21
9.31
9.41
9.48
9.56
9.67
Overall
Dimension
<mm>
1960×992×40
1960×992×40 weight
<kg>
22.4
22.4
ANNEX D: MODULE CLEANINg gUIDELINE
This manual covers requirements for the cleaning procedure of Canadian Solar Inc. photovoltaic modules. The purpose of these cleaning guidelines is to provide general information for cleaning
Canadian Solar modules. Professional installer should read these guidelines carefully and strictly follow these instructions.
Failure to follow these instructions may result in death, injury or property damage to photovoltaic module. Damages induced by inappropriate cleaning procedures will void Canadian Solar warranty.
SAFETy wARNINg
· Cleaning activities create risk of damaging the modules and array components, as well as increasing the potential electric shock hazard.
· Cracked or broken modules represent an electric www.canadiansolar.com
18 | shock hazard due to leakage currents, and the risk of shock is increased when modules are wet.
Before cleaning, thoroughly inspect modules for cracks, damage, and loose connections.
· The voltage and current present in an array during daylight hours are suicient to cause a lethal electrical shock.
· Ensure that the circuit is disconnected before starting the cleaning procedure as contact with leakage of electrically active parts can result in injury.
· Ensure that the array has been disconnected to other active components (such as inverter or combiner boxes) before starting with the cleaning.
· Wear suitable protection (Clothes, insulated gloves, etc.).
· Noticeable dirt must be rubbed away by gentle cleaning implement (soft cloth, sponge or brush with soft bristles).
· Ensure that brushes or agitating tools are not
abrasive to glass, EPDM, silicone, aluminum, or
steel.
· Conduct the cleaning activities avoiding the hottest hours of the day, in order to avoid thermal stress on the module.
Recommended the following to be used:
· Water with low mineral content
· Near neutral PH water
· The maximum water pressure recommended
is 4 MPa (40 bar)
CLEANINg METhODS
· Do not immerse the module, partially or totally, in water or any other cleaning solution.
hANDLINg NOTICE
· Use a proper cleaning solution and suitable cleaning equipment.
· Do not use abrasive or electric cleaners on the module.
· Particular attention should be taken to avoid the module backsheet or frame to come in contact with sharp objects, as scratches may directly affect product safety.
· Do not use de-greasers on the module.
· Do not use cleaning corrosive solutions containing
acid, alkali, acetone, or industrial alcohol.
· Canadian Solar Inc. recommends to avoid rotating brush cleaning method, as it can lead to the formation of micro cracks.
Method A: Compressed Air
Canadian Solar Inc. recommends cleaning the soft dirt (like dust) on modules just with air pressure. This technique can be applied as long as the method is efficient enough considering the existing conditions.
Method B: wet cleaning
If excessive soiling is present on module surface, a non-conductive brush, sponge, or other mild agitating method may be used with caution.
· Ensure that any brushes or agitating tools are constructed with non-conductive materials to minimize risk of electric shock and that they are not abrasive to the glass or the aluminum frame.
· If grease is present, an environmental friendly cleaning agent may be used with caution.
AMENDMENT EDITIONS AND DATES
· The first edition Rev A1 is released in Apr, 2014.
· The second edition Rev A2 is released in Dec, 2014
· The third edition Rev A3 is released in Aug, 2015
· The fourth edition Rev A4 is released in Mar, 2016
· The fifth edition Rev A5 is released in June, 2016
· Dirt must never be scraped or rubbed away when dry, as this will cause micro-scratches on the glass surface.
OpERATION pREpARATION
EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
CANADIAN SOLAR INC.
545 Speedvale Avenue West, Guelph, Ontario, Canada N1K 1E6 www.canadiansolar.com
|
19
Advertisement