Indesit TNFP3303 TEL refrigerator Technical documentation

Indesit TNFP3303 TEL refrigerator Technical documentation

The TNFP3303 TEL is a refrigerator with a variety of features, including a no-frost freezer, a spacious refrigerator compartment, and a variety of shelves and drawers. It is designed to keep your food fresh and organized. The TNFP3303 TEL also has an easy-to-use control panel with a variety of settings so you can customize your refrigerator to your needs.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Indesit TNFP3303 TEL technical documentation | Manualzz

Model type:

TNFP3303TEL

Commercial code:

General notes

Technical Documentation guidelines

----------------------------------------------------------------------------------------------------------------------------------

-------------------------------------------------------------

You can find herewith some generic information to simplify cunsulting of technical documentation:

1. Models of same range share the same exploded views, which report the richest set of spare parts:generally, a model does not necessarly have a related spare part for each particular shown on exploded views.

2. Some spare parts can not be represented directly on the exploded views (instruction booklets, specific kit, etc...). You can find those codes in the spare parts list with the same reference of particular where spares are installed or with references 099, 999.

Instruction booklets, once managed, appear with 000 reference.

3. On the higher right site of each exploded view there is a serial number which indicates the beginning of the production of certain range:some models might have more than an exploded view for a given category, each distinguished by a different serial no.and linked to another spare parts list, In this case, serial no. is required to supply the right spare part code. Exploded view to be considered is the one with a more recent serial no. but previous than the one of the model that needs assistance.

4.Exploded views might require further updates even after publishing. Addition of new spares will go on following the already existing numeration references. Revision number of an exploded view is shown into last four digits of serial number into upper right hand corner.

5.The spare parts list associated to an exploded view shows related codes of spares managed for a certain model; for each spare part other informations are available:

REF: reference no of spare into a table; SUBSTITUTE: list of spare(s) which can replace a code but that keeps same functional characteristics

INDUSTRIAL CODE: list of variables of a model (shown into model label) where such spare is used; NOTICE: code of information(s) to refer to complete technical intervention, track for changes or to find correct spare part code.

6. Some notices, into a same section are generic therefore cannot be directly linked to a spare part. In order to assist a model in the best way as possible, it is helpful to pay attention to all notices and constantly verify documentation updates

7.Technical documentation cover shows model name and its commercial codes mod.TNFP3303TEL page 2

5133030 Exploded views mod.TNFP3303TEL page 3

025

026

026

026

023

024

024

025

026

027

019

020

021

022

015

016

017

018

5133030 Spare parts list

Notice Industrial Ref.

010

011

012

013

014

005

007

007

009

001

002

002

003

003

004

004

Code С сер.№ По

C00016413

C00026582

C00040183

C00026590

C00040189

C00021990

C00021991

C00015745

C00028437

C00030660

C00025232

C00025231

C00025229

C00025230

C00025891

C00025907

C00023305

C00023304

C00023303

C00023316

C00024308

C00024273

C00024301

C00022011

C00017812

C00022013

C00047949

C00024340

C00024341

C00024290

C00024292

C00029242

C00029243

C00024305

Substitute Description

1 x C00028137 cord lead'rf340-rf340el'

1 x C00040183 white26 cover 600x492x32 (holewhite26 cover 600x492x32 (holewhite26 dashboard base no-frost white26 dashboard base no-frost hinge upper lh hinge upper rh

2 x C00032223

1 x C00042672

1 x C00042673 hinge pin - m6x(5+14) grey11 set dashbpard m.60

grey11 set dashboard m.60(20 white upper meat-holder tray neutral col.44 flap tray meatwhite lower meat-holder tray slide foot (lower meat tray) - white no-slip gasket central hinge zncr central hinge (non-slip

1 x C00032099 white grid inclinable wxhxd white retracting grid white overturnable grate trim - wire shelf white white lateral pipe separator white separator front plate (fridge floor) - white lower hinge chromium hinge pin (m8x5-20) separator fixing plate chromium separator fixing plate cromium runner spacer rh - white runner spacer lh - white separator refrigerator runner dx separator refrigerator runner sx runner support rh runner support lh support (fridge floor) - white

0513189

0513254

0513253

0513254

0513254 mod.TNFP3303TEL page 4

5133030 Spare parts list

Notice Industrial Ref.

033

034

035

036

038

039

028

029

030

031

031

032

032

Code С сер.№ По

C00022017

C00023283

C00023297

C00017771

C00032232

C00023300

C00023301

C00021591

C00026592

C00021989

C00023299

C00011286

C00017792

Substitute

1 x C00043862

1 x C00041042

1 x C00022198

1 x C00114785

Description винт m5x15 ts base dx-sx aluminium lower hinge dx-sx zncr foot 10x36- adjustable foot support m10 (37x55 mm) support rh (wire shelf) - white support lh (wire shelf) - white

"o" washer 8x4x2 - thermostat disc (temperator sensor probe) blue swab refrigerator 20x30 bush 6,8mm (wire shelf) - white заглушка белая d.4,5x8 mm spacer - condenser mod.TNFP3303TEL page 5

5133130 Exploded views mod.TNFP3303TEL page 6

5133130 Spare parts list

Notice Industrial Ref.

010

011

012

012

008

009

010

010

001

002

003

004

005

006

007

017

018

019

020

012

013

015

016

021

022

Code С сер.№ По

C00026570

C00024267

C00025238

C00025241

C00023280

C00022166

C00026519

C00023343

C00025236

C00025237

C00026609

C00026610

C00023312

C00023272

C00026551

C00026722

C00023342

C00025235

C00025233

C00025234

C00022165

C00022029

C00022030

C00022017

C00022031

022 C00022032

Substitute Description push-button (fan no-frost) - white втулка белая 7x21,5 mm white inner door freezer'impronta

1 x C00028106 white freezer shelf mod.600 (noaluminium recessed knob door white bush for door stop (h=6mm) blanking plug white 26 (bush)

1 x C00032298

1 x C00030609 втулка белая с отверстием cover - small box white small garlic box - white white smal box for onion small lemon box - white лоток для яиц (9) белый sliding separator (bottle shelf) -

1 x C00023341 white boxes shelf serig.(no-frost)

1 x C00023270 white shelf bottle mod.600 (nohinged shelf (218mm) - white

1 x C00028112 white separator for marsupial shelf white shelf with marsupial white smal sink for marsupial white bush for door stop screw m5x14 tc shoulder screw m5x10 - door винт m5x15 ts white runner drawer dx blum 1 x C00029240

1 x C00029241

1 x C00029242

1 x C00029243

1 x C00029965

1 x C00029966

1 x C00029240

1 x C00029241

1 x C00029242

1 x C00029243

1 x C00029965 white runner drawer sx blum mod.TNFP3303TEL page 7

5133130 Spare parts list

Notice Industrial Ref.

031

032

033

034

027

028

029

030

022

022

023

023

024

025

026

039

040

041

042

035

036

037

038

Code С сер.№ По

C00029240

C00029241

C00022033

C00022154

C00024276

C00022034

C00022076

C00024288

C00024278

C00024350

C00024337

C00024349

C00024347

C00024279

C00024348

C00024339

C00023808

C00023367

C00025240

C00025239

C00023511

C00023500

C00021255

Substitute

1 x C00065734

1 x C00024285

Description drawer runner lh - white drawer runner rh - white drawer angle bracket - white plastic washer (12x6,1x3mm) adjustable drawer rack plate m5 (20x20x4) drawer partition - white cellar drawer (w= 491 mm) прокл. серая y58 дверцы отд.

white26 third door recessed aluminium third door frame (wxh aluminium recessed knob85 third white door liner refrigerator(bxh прокладка дверцы white26 refrig.door recessed aluminium refrige.door

alum.recessed knob refrigerator aluminium label holder tropical прокладка дверцы морози-ка freezer inner door insulation white26 frezer door recessed freezer door frame blanking plug (8,5mm) - white

0513185 mod.TNFP3303TEL page 8

5133220 Exploded views mod.TNFP3303TEL page 9

5133220 Spare parts list

Notice Industrial Ref.

015

016

017

018

008

010

011

012

001

002

003

004

005

006

007

021

023

025

028

018

018

019

020

029

030

Code С сер.№ По

C00026608

C00007225

C00026607

C00025221

C00026597

C00025227

C00026593

C00026598

C00014612

C00025228

C00025223

C00026681

C00026682

C00025211

C00026614

C00028100

C00028101

C00026947

C00028114

C00010517

C00008591

C00013997

C00006495

C00008471

C00017856

Substitute Description

1 x C00117027 ванночка для льда 246x110 пластиковый упругий стопор cover - ice tray (plastic) ванночка для льда белая ice tray support- white freezer flap door (l=342)- colour панель акк. холода белая с white separator freezer(493x276) расширитель freezer base tray (494x351) днище морозильной камеры pipes grommet (de.24 x 21 mm) fuse-thermic fixing plate (no-frost) freezer evaporator (b=350x153) drip w.outlet pipe-rubber

1 x C00009337 non return valve - defrost water connector - defrost pipe/non drip water outlet pipe sping (nodefrost water tray - metal screw m6 earth plate compressor asperaдержатель компрессора 586 x rubber shock absorber 1 x C00032453 пластина крепления

1 x C00104762 compressor b1116a-b1116b 220-

0513231

0513181

0513203

0513218

030

031

031

032

033

C00025755

C00009319

C00031162

C00006418

C00023282

1 x C00104762 comp.embraco ff8,5bk 220-240v

1 x C00042354 charging pipe 6x70 suction connection filter конденсатор h=1000+200x591

0513205 mod.TNFP3303TEL page 10

5133330 Exploded views mod.TNFP3303TEL page 11

5133330 Spare parts list

Notice

0513223

Industrial Ref.

006

007

008

009

010

015

001

001

002

003

004

004

005

Code С сер.№ По

C00026612

C00038969

C00023288

C00006522

C00023295

C00038970

C00007225

C00009882

C00009888

C00008867

C00023294

C00010097

C00026725

Substitute

1 x C00029307

Description white false knob box white false knob box centerlamp cover лампочка 220-240 в/15 вт (e14) thermostat box(no switch hole)thermostat box white centerпластиковый упругий стопор патрон для лампочки e14 кабельный зажим выключатель освещения libero white push-button light switch supply cable 3x0,75 anti condensation heater 5w

0513223 mod.TNFP3303TEL page 12

5133420 Exploded views mod.TNFP3303TEL page 13

016

017

017

018

018

019

021

008

008

009

010

011

012

013

014

014

015

016

5133420 Spare parts list

Notice

0513189

Industrial Ref.

005

005

005

005

006

008

001

001

002

003

004

005

005

Code С сер.№ По

C00028437

C00030660

C00025243

C00025215

C00025218

C00026604

C00027214

C00027220

C00028105

C00030655

C00030656

C00026591

C00026606

Substitute

1 x C00026601

1 x C00027220

1 x C00032408

1 x C00028104

Description grey11 set dashbpard m.60

grey11 set dashboard m.60(20 fan push-button n.a. 1051 (noпрокладка резиновая двигателя fan blade (mes) probe eutectic l.850 mm faston probe refrigerator l.1200 mm probe refrigerator l.1450 mm датчик аккум. холода l.850mm

probe refrigerator l.1450 mm probe refrigerator l.1200 mm cover (temperature sensor) - white card mask microprocessor

0513189

0513189

0513189

008 C00027258 1 x C00026606 card masck microprocessor faston

0513189

0513191

0513191

0513193

0513192

0513193

C00030657

C00030658

C00025244

C00026652

C00026654

C00025245

C00026960

C00026687

C00028116

C00026633

C00025210 плата микропроцессора .masк

1 x C00030657 card masck microprocessor molex insulation lower box (noadhesive sponge seal (7x610x4) adhesive sponge seal (30x150x4) lower cover - grey wiring bush (no-frost) wiring protection 194 mm (nowiring protection 194mm (noupper cover - grey defros.res.20w 220v(faston) 0513189

0513212

0513212

0513189

C00028085

C00027622

C00028084

C00025216

C00028078

C00025217

C00027222 нагреватель для оттаивания 20 тэн 72 вт 220 в (faston) элемент нагрев. 72 вт 220 в

1 x C00028078 fan-motor (mes-plaset) connector двигатель вентилятора

1 x C00028083 cover - fan-motor therm.elth261177 + fuse

0513189

0513189 mod.TNFP3303TEL page 14

5133420 Spare parts list

Notice Industrial Ref.

021

021

022

022

Code С сер.№ По

C00028083

C00030291

C00026790

C00028069

Substitute Description тепл. защ. реле elth 261n356 + adhesive small spogne

10 wire flat cable display

20 wire flat cable display board

0513189 mod.TNFP3303TEL page 15

Notices

0513178: 3W HEATING ELEMENT FOR SEPARATOR IN "CELLAR" COMPARTMENT

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

The current anticondensation resistance mounted in the separator of the refrigerator compartment of the 3 door models has been modified as follows: the length according to the 600 or 550 refrigerator module; the type of cap or faston terminal for connection to the terminal board.

The following prospectus illustrates the resistances which are currently used:

.BF bold

Models DF2853T and DF330S3T module 600 in class N and T

.pf

026585 - 3W 220V, 325 mm long resistance with cap terminals.

This resistance will also be used on the new no-frost mechanical models.

026725 - 3W 220V, 325 mm long resistance with 4,8x0,8 female faston terminals.

This resistance is used specifically for all the electronic versions of the no-frost models. An Aspera B1116A compressor will in fact be mounted on these models with a Blu-Box type terminal board with faston connections.

.bf bold

Models DF2603T and KDF2603T module 550

.pf

024274 - 3W 220V, 285 mm long resistance with cap terminals.

This resistance is used specifically for models DF2603T with exception of the French version produced under the (NF) trademark.

022050 - 3W 220V, 285 mm long resistance with 4,8x0,8 female faston terminals.

This resistance is used specifically for model DF2603TF, produced for France under the (NF) trademark.

0513181: NO-FROST FREEZER EVAPORATOR MADE TO RUN QUIETER

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

The modification for the noiseless freezer evaporator has been introduced as from serial no. 802010001 on the no-frost mechanical and electronic versions.

The following parts have been modified:

025211 - ventilated evaporator (h=1590 mm) (The position of the input and output pipes is 30 mm lower and the diameter of the delivery pipe has been reduced from 6 to 4 mm)

025222 - freezer bottom insulation (the bottom corners project by 30 mm)

The new freezer evaporator may be used to replace the old type. In this case however the fixing holes on the freezer cell should be re-made with a 3 mm diameter bit (depth 10 mm).

-VT cell and NT evaporator take the holes 32 mm higher

The old fixing holes of the evaporator should be closed with silicone.

mod.TNFP3303TEL page 16

The modified insulation bottom should also be installed.

If the old evaporator is to be used instead of the new type, the following problems will be encountered:

-when the new holes are made on the freezer cell (NT cell and VT evaporator take the holes 32 mm lower), the holes coincide outside the sheet plate reinformcement behind the refrigerator cell side.

-the freon in the old evaporator starts expanding in the rising section of the delivery pipe (immediately after the weld to the capillary) and therefore the evaporator is noisy.

Noise on the new evaporator has been eliminated by modifying the diameter of the delivery pipe: external diameter reduced from

6 to 4 mm and the internal diameter from 4 to 2 mm in order to have a direct connection to the capillary.

In addition the section of the delivery pipe connection to the freezer evaporator coil terminates as a Venturi pipe.

With these modifications the freon starts to expand inside the freezer, immediately after the weld between the Venturi pipe and the coil in the horizontal section of the upper part of the evaporator.

In addition using the old evaporator on the new products, the 30 mm which project from the bottom corner of the bottom insulation must be removed.

The new freezer evaporator and the new freezer bottom insulation will be indicated under the same sat codes as the previous versions.

0513185: REPLACEMENT OF PLATE (20X20) FOR FASTENING GUIDES ON 3-DOOR UNITS

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

On the three-door version refrigerators, the M5x15TS (022017) screw used for fixing the guides to the refrigerator separator or to the cellar compartment drawer, has been replaced by 8Px19,5xTSP self-threading screws.

The 8Px18x12 plate must be used with the self-threading screw instead of the square M5 (022034) plate.

On the refrigerator separator and on the cellar compartment drawer the plate housings have been modified (the depth has been decreased from

10,1 to 7,1 m.).

On the new modified parts the previous fixing system may be used by changing the sizes of the square plate from 20x20 to 20x14 mm .

The new fixing system may be used on premodification models.

The modified spare parts are indicated under the previous sat code.

0513189: NOTICE FOR MOLEX CONNECTIONS ON NO-FROST FRIDGE

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from serial no. 903150001 the new Molex connector system will be introduced in all no-frost refrigerators.

The new spare pars with molex attachments are not interchangeable with premodification parts. The description for the spare parts has been changed by adding the word Molex or FASTON to indicate the type of attachment.

The ELTH 261356 (028083) thermoprotector has different attachments and new ratings (activates at +8°C/disactivates at

-10°C) with respect to the previous model, the ELTH 261177 (027222).

With the new ratings the plastic plate fitted during assembly on the freezer evaporator has been eliminated (definitely for all versions); the adhesive sponge (030291) is still fitted around the thermoprotector.

On the electronic version the dashboard unit (030659

030660-030661-030662-030663) are fitted with a flat 20 wire cable connecting these to the electronic board with Molex attachments. On the previous version the dashboard and the electronic board with Faston attachments are connected with the round 10 wire cable.

The description of the dashboard unit NT and VT indicates whether this is for the 10 or 20 wire cable.

The flat cable has led to the modification of the cabling sheath

026687 which has been replaced by the 028116. The latter may also be fitted on premodification models.

mod.TNFP3303TEL page 17

0513191: RELEASE2 CARDS WITH FASTON TERMINALS

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As a result of the introduction of new electronic boards (release-2) on no-frost refrigerators, these boards will be supplied both with Molex and Faston attachments.

The release-2 boards with Faston attachments will be indicated under the previous sat codes (release-1):

-code 026606 for Italian and European models

-code 027258 for Spanish and Greece models

These new boards are interchangeable with the release-1 board (including the version with radio anti-disturbance filter).

With respect to the diagram (5130412A) shown in the Servicing

Manual the new boards have the AC contacts on the bottom right hand side.

IMPORTANT

Release-1 boards can be transformed into release-2 boards by replacing the microprocessor integrated with other components on the main board. In this case the AC contacts remain on the bottom left hand side.

---AUTOTEST

---When the refrigerator is switched On the first time and after a power failure, an automatic autotest lasting approx. 1 minute is carried out.

This autotest procedure is as follows: all the LEDs flash (three times), the compressor and fan operate continuously, the freezer defrosting heating elements switch ON intermittently.

After the initial flashing the system sets automatically to

+5°C in the refrigerator and at -12°C (alarm) in the freezer.

During the autotest the keyboard can not be used.

The keyboard can be used again after 1 minute and the real temperature is indicated in the freezer.

---FORCING A FREEZER DEFROSTING CYCLE

---To activate a forced defrosting cycle follow these steps:

:sl

---a) Check that the fast freezing is not ON.

If necessary press the button to switch OFF.

---b) Open the freezer door and leave it open.

---c) Hold down the alarm pushbutton (buzzer) until a Beep signal is il is given (after about 5 seconds) which indicates that the forced defrost command has been accepted.

Defrosting now starts and you may close the freezer door.

If the compressor and fan are ON when the forced defrosting starts, the compressor switches OFF immediately whilte the fan switches

OFF after 3 minutes and only then does the defrosting cycle start.

:esl

---SWITCHING ON THE LED -24°C (SUPER).

---The thermometer readings have been "manipulated" so that they visualize the temperature in the storing area and not the temperature where the foodstuff to be frozen has been stored. The thermometer therefore behaves as follows:

:sl

---a) During normal operation the -24°C LED (or SUPER LED in the case of the new restyling-88 dashboard) never switches on.

---b) During fast freezing the -24°C LED (or the SUPER LED in the case of the new restyling-88 dashboard) is always on (other than when the alarm is ON).

To "conceal" the thermometer manipulation, this LED switches on with a certain delay with respect to the start of the freezing cycle.

This delay depends on how cold the refrigerator is and ranges from a minimum of 5 minutes to a maximum of 60 minutes.

After freezing, when the freezer returns to NORMAL operation, the -24°C LED (or the SUPER LED in the case of the new restyling-88 dashboard) stays ON for another 4 or 5 minutes.

:esl

---DEFROSTING DURING FAST FREEZING

---All the defrosting cycles are stopped in the first 11 hours during the fast freezing cycle, so as to avoid any interference with the first freezing phase which is the most important.

mod.TNFP3303TEL page 18

A freezer defrost cycle is always carried out after the 11th hour.

0513192: RELEASE2 CARDS WITH MOLEX TERMINALS

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from the middle of July-89 the release 1/A electronic board on the No-frost refrigerator models with Molex attachments have been replaced with the new release-2 board with automatic autotest. These new board is coded under the previou sat code as follow: code 030657 for the Italian and European models

With respect to the diagram (5130652A) shown in the Servicing Manual the new card no longer have the "JAMPER" contacts for the autotest.

Release-2 board has the following innovations:

---AUTOTEST

---When the refrigerator is switched On the first time and after a power failure, an automatic autotest lasting approx. 1 minute is carried out.

This autotest procedure is as follows: all the LEDs flash (three times), the compressor and fan operate continuously, the freezer defrosting heating elements switch ON intermittently.

After the initial flashing the system sets automatically to

+5°C in the refrigerator and at -12°C (alarm) in the freezer.

During the autotest the keyboard can not be used.

The keyboard can be used again after 1 minute and the real temperature is indicated in the freezer.

---FORCING A FREEZER DEFROSTING CYCLE

---To activate a forced defrosting cycle follow these steps:

:sl

---a) Check that the fast freezing is not ON.

If necessary press the button to switch OFF.

---b) Open the freezer door and leave it open.

---c) Hold down the alarm pushbutton (buzzer) until a Beep signal is il is given (after about 5 seconds) which indicates that the forced defrost command has been accepted.

Defrosting now starts and you may close the freezer door.

If the compressor and fan are ON when the forced defrosting starts, the compressor switches OFF immediately whilte the fan switches

OFF after 3 minutes and only then does the defrosting cycle start.

:esl

---SWITCHING ON THE LED -24°C (SUPER).

---The thermometer readings have been "manipulated" so that they visualize the temperature in the storing area and not the temperature where the foodstuff to be frozen has been stored. The thermometer therefore behaves as follows:

:sl

---a) During normal operation the -24°C LED (or SUPER LED in the case of the new restyling-88 dashboard) never switches on.

---b) During fast freezing the -24°C LED (or the SUPER LED in the case of the new restyling-88 dashboard) is always on (other than when the alarm is ON).

To "conceal" the thermometer manipulation, this LED switches on with a certain delay with respect to the start of the freezing cycle.

This delay depends on how cold the refrigerator is and ranges from a minimum of 5 minutes to a maximum of 60 minutes.

After freezing, when the freezer returns to NORMAL operation, the -24°C LED (or the SUPER LED in the case of the new restyling-88 dashboard) stays ON for another 4 or 5 minutes.

:esl

---DEFROSTING DURING FAST FREEZING

---All the defrosting cycles are stopped in the first 11 hours during the fast freezing cycle, so as to avoid any interference with the first freezing phase which is the most important.

A freezer defrost cycle is always carried out after the 11th hour.

mod.TNFP3303TEL page 19

0513193: ELECTRONIC RELEASE2/R45 CARD ELIMINATED - SPAIN

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from serial no. 909060001 the same electric board currently used for the respective Italian models, are now mounted on the

No-Frost refrigerators for Spain and Greece.

The board in question is release-2 version 030657, Molex attachment and automatic autotest function (see notice 192).

The previous boards with specification R45 for the electronic no-frost tropical version:

027258 release-1 with Faston attachment;

030658 release-1/A with Molex attachment; will no longer be supplied as spare parts since they are interchangeable with the release-2 version for Italy with both the Faston

026606 attachment and Molex 030657 attachment.

The use of the new boards will make it possible to have a temperature of about 2° C less in the refrigerator compartment.

The electric diagram in the Owner's Manual between the version for Italy and the version for Spain are identical.The difference was due to the use of a R45 heating element.

0513197: 20W HEATING ELEMENT FOR DRIP CHANNEL FOAMED TO CABINET

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from serial no. 001110001 the 20W wire heating element on all the 2 and 3 door models of the Nofrost series, including the recessed model, is mounted under the drip tray of the freezer compartment and foamed together with the cabinet.

In the case of heating element failure, use the previous version with the heating element of the drip tray mounted outside (see

Service Manual chapter 3.7).

0513203: ASPERA COMPRESSOR FOR NEW UNIFIED "B" SERIES

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Aspera has standardized the "A" and "B" series compressor codes to the "B" series codes.

The compressors in the new series can be interchanged with the premodification models with exception of the 220-240V 50HZ models B1112B - B1116B - B1118B which have the new motors and are therefore interchangeable only with relevant equipment

(see table Fig. 99 Ed.1).

The new compressors will have the same sat codes as the previous models with the descriptions showing the new codes.

The old and new codes of the Aspera compressors used as spare parts are listed as follows:

A Series B Series Standardized B Series

A1055B A1075A A1085A A1111A A1116A A1118A A1112A A3112A A2111A A2116A A3112A B1112A B1116A B1118A

B2112A B2116A B1055A B1075A B1085A B1112B B1116B B1118B B1113A B3113A B2112B B2116B B3113A

0513205: SPECIAL WELDING (WELDING YOKE) ON COMPRESSOR

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------mod.TNFP3303TEL page 20

When replacing the compressor, if you find that it has a special solder (VULCAN ring and LOKPREP-61 seal), you should should remove this and replaced it with a standard copper-iron solder using the connection pipe (aluminium-copper) 031162. The two ends should be shaped for connecting to the aluminium return pipe (int.diam. 7.1 mm) and the compressor (ext. diam. 6 mm).

After the aluminium pipe has been cut above and below the ring, and the connection pipe has been fitted, you may now make the solder (copper-iron) with the silver alloy and (aluminium-aluminium) with the Castolin or other alloy for the aluminium.

The connection pipe 031162 must also be used if the special solder is lost since the seal provides no guarantee whatsoever unless the ring is held by the VULCUN clip.

0513212: WIDE-BAND 20W HEATING ELEMENT FOR DRIP CHANNEL

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from October 1991, the codes 028085 (molex attachments) and

025210 (faston attachments) refer to the 20 W drip tray with large band which replaces the previous type with narrow band.

In the version with wide band, the sizes of the aluminate sheet are as follows: width 470 mm and depth 130 mm.

This new heating element has major hold and heats a wider area as well as the drip tray.

To ensure that the heating element is positioned correctly, remember that the drain hole of the drip tray must coincide with the slotted part of the aluminate sheet (leaving the cables on the left).

Before removing the protection film from the adhesive tape, shape the aluminate sheet according to the shape of the drip tray.

After having removed the protection film from the adhesive tape and before positioning the aluminate sheet, ensure that the two edges overlap in order to avoid large folds at the ends when these are fixed.

Fit the aluminate sheet, keeping it towards the top and start gluing from the drain hole following along the edge of the heating element (press down firmly with your hands in order to prevent air bubbles from forming).

Complete the gluing procedure with a cloth to prevent the formation of large folds at the two ends.

Once the parts have been fixed, carefully fold one of the two edges of the cut into the drain hole using a medium cross-head screw driver.

Do not damage the wire of the heating element.

Important: after having removed the heating element you are replacing, remember to dry and clean the surface of the drip tray thoroughly.

0513218: ASPERA TERMINAL BOARD WITH FASTON TERMINALS

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

On Aspera compressors two types of terminal boards are used: the first one with screw attachment and the second one with faston attachment.

The compressors which at the moment use the two types of terminal boards are the following:

---B1116A 220-240V 50 Hz

---B1116B 220-240V 50 Hz

---B1116B 200-220V 50 Hz and 230V 60 Hz

---B1118A 200-220V 50 Hz

For these compressors the terminal board with faston attachment has been coded complete of the equipment while the terminal board with screw attachment has been coded separately being a common part of the other models of compressors.

The codes of the complete terminal boards are as follows:

021669- B1116AF 220-240V 50Hz terminal board

038757- B1116BF 200-220V 50Hz/ 230V 60Hz terminal board

038758- B1118AF 200-220V 50Hz terminal board

034776- B1116BF 220-240V 50Hz terminal board

The Aspera compressors coded as spare parts already include the equipment and therefore the wiring and the terminal board attachment may be incompatible while used.

The wiring with faston terminal can be modified cutting the head of the faston off; while on the other hand it is necessary to mod.TNFP3303TEL page 21

replace the terminal end with the faston.

0513221: REINS. SERPENTINA(RAME) X FRIGO NO-FROST

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from serial no. 20729.0001 in all no-frost refrigerators (mechanic and electronic ones) the copper refrigerating coil has been reintroduced in replacement of the aluminium one in order to guarantee a higher corrosion strength of the refrigeration circuit.

With the copper refrigerating coil the special cold welding is no longer used and therefore the Vulcan rings and the Lookprep-61 dope have been eliminated.

0513223: FAKE KNOB ON CENTER-POST BOXES

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

From serial number 20921.0001 the thermostat boxes (triangular) in

Center-Post version are also used as light boxes in the electronic no-frost refrigerators.

The Center-Post boxes (038970) are interchangeable with the previous ones only if complete with the mock knob (038969) having two diametrically opposed hook teeth on the outer edge.

The box and the mock knob of the old and new version are not interchangeable individually with each other.

The old box (023295) and the corresponding mock knob (026612) with hook teeth on the center pin will be used until stock runs out.

0513224: CLOGGING OF DRAIN HOLE ON NO-FROST FRIDGE

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

When on no-frost refrigerators at the end of a freezer defrost the ice clogs the drain hole or ducting, do as follows:

--- Check that the 20-W drip heating element is well glued and operative, otherwise replace it.

--- With a hair-dryer remove ice residue and check that the water flows down through the drain hole and to the compressor tray.

--- Insert the aluminium rod (039719) in the hole, the bent end resting on the lowest element of the armoured heating element (60-

72 W) mounted on the freezer evaporator.

If the height of the evaporator is less than 9 cm compared to the drip hole, shorten the rod about 3 cm.

To improve distribution of heat inside the drain hole, block the rod on the armoured heating element with a piece of aluminium tape (027058).

The aluminium rod, code (039719), will be equipped with a drawing to explain assembly.

fig.5131539A

A ICE

0513231: NEW REFRIGERATING LIQUID (EUTETTICO) FOR NO-FROST FRIDGE

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from the March-93 production the freezer separator 026598 with eutectic-holder tray on no-frost refrigerators has been modified for use with the new eutectic packet.

mod.TNFP3303TEL page 22

The depth of the tray has been increased from 36 - 40 mm.

The new eutectic packet, which will be used from April, has a liquid with a different composition which does not contain methylene blue and a new system for the container and the radiating surface, which are no longer sealed together.

The eutectic container which consists of a single hot sealed packet, is fixed to the radiating surface with four 6,3 x 13 mm stainless steel screws.

The new eutectic packet will have the same sat code 026593 as the previous part; it may be mounted on premodification products provided the freezer separator is replaced.

0513252: KIT FOR FAN MOTOR WITH PART NO. 042301 (SAT)

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from July-94, Kit 042301 for the 220-240 Volt 50-60 Hz electric fan unit, is supplied as a spare part. This should be used for recessed and free standing appliances with bad performance in the refrigerator compartment and thermostats whose cycles do not run, even when set to minimum.

Naturally, the problem is not caused by the discharge circuit, but by unstable operating conditions with a high room temperatures.

The electric fan should be mounted on the compressor cross-piece or on the plastic base (94-range), as shown in the drawing provided with the kit.

It is important to place the fan in an "open" position because air must be drawn from the interior and discharged to the exterior through the condenser flue.

Important

The fan should never be positioned facing the terminal board of the compressor, because it would cool the klixon and prevent this from operating correctly.

Before returning the appliance into its original position, check that the fan turns freely, removing obstacles such as cables, pipes or capillaries.

The electric connection of the electric fan should be made on the terminal board of the compressor, using the contact of the black wire (thermostat return) and the contact of the blue wire (neutral).

The following kit components are also available as individual spare parts: mod.TNFP3303TEL page 23

---032385 - fan motor support

---025215 - fan motor rubber part

---025218 - motor fan (MES)

---032384 - fan motor DX (MES)

0513253: NEW HINGES FOR 3-DOOR FRIDGE (SMALL TOOTH)

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from the January-95 production, a new bottom hinge will be mounted on all 550 and 600 mm 3-door refrigerators; the new hinge differs from the previous in that it has a tooth at the back.

This tooth fixes the hinge into the 6 mm hole on the facia of the refrigerator separator in order to keep the door constantly aligned.

The new hinge will be supplied under the same sat codes as the previous part (022155-022011-029076); when using the new hinge on the pre modification models, it will be necessary to eliminate the back tooth or drill a hole in the facia of the separator at the same level as the tooth. The tip must enter for a depth of at least 5 mm in order to pass through the refrigerator separator.

0513254: NEW SEPARATOR PLATE FOR 3-DOOR FRIDGE

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

As from the January-95 production run, all three-door 550 and 600 mm refrigerator models have a new refrigerator separator which has a different front panel with different fixing holes on the separator plate (opposite the centre hinge) with respect to the previous one.

The distance between the fixing holes on the plate has been increased from 30 to 46 mm in order to distribute the weight of the separator better.

The cover of the separator (022012-024301) will be supplied with the 6 mm on both sides.

The new fixing plate with painted, chromed and zama finish will be supplied under the following codes (047948-047949-046235) which replace the previous codes (022013-022156-029077).

The new refrigerator separator will continue to be supplied under previous sat code (030228-024273) complete with the new parts

(cover - centre hinge - fixing plate). It may also be mounted on premodification models.

mod.TNFP3303TEL page 24

Electric schemes and links

Cod. 513008b mod.TNFP3303TEL page 25

CO

EV

FA

IDS

IEC

IEFR

IETH

ILFR

ILFZ

ILI

M

MO

MT

MV

MVCO

BZ

C

CM

L

LFR

LFZ

LI

IP

IR

ISC

IV

CM

CO

FA

IDS

ILFR

ILFZ

ILI

Legend

Legend: 513008b

Running capacitor

Compressor

Radio anti-trouble filter

Schackler with warning

Push-button for fridge lamp/fan

Push-button for freezer lamp/fan

Lamp switch

Door switch

Line switch

Warning light-freezing switch

Fan-motor switch

Line

Fridge lamp

Freezer lamp

Lighting lamp

Mass/Eart symbol

Terminal board

Timer motor

Fan motor

Compressor compartment fan

Audio freezer alarm

Surge Capacitor

Running capacitor

Compressor

Electrovalve

Radio anti-trouble filter

Schackler with warning

ON OFF loads switch

ON OFF refrigerator switch

Thermostat exclusion

Push-button for fridge lamp/fan

Push-button for freezer lamp/fan

Lamp switch

RFZ

RH

RS

RS1

RS2

RS3

RS4

RTA

SA

SC

T

TC

TF

THI

THR

R

RA

RAN

RS

RS1

RS2

SDC

SL

SND1

SND2

SND3

N

PTC

R

RA

RAN

RFZ

RH

Neutral

PTC relay

Heating resistance

Ammetrical relay

Heating element condensation

Heating element condensation freezer

Thermal relay

Defrosting resistance

Defrosting resistance no-frost evaporator

Defrosting resistance no-frost gutter

CONTROL CARD DIAGRAM

Line warning

PROBE REFRIGERATOR EVAP.

AIR-PROBE FREEZER

AIR-PROBE REFRIGERATOR

Erden

Turbocooling

Fuse-thermic

Thermostat switch

Adjustable thermostat

Heating resistance

Ammetrical relay

Heating element condensation

Heating element condensation freezer

Thermal relay

Defrosting resistance

No frost evaporator resistance

No frost drip pan resistance

Defrosting resistance

Defrosting resistance

Thermo actuator defrosting resistance

Allarm warning

Freezing warning mod.TNFP3303TEL page 26

C

CA

DV

EF/CL

EF/L

EF/P

ER

ET

MVFZ

N

PTC

AQS

B

BC

BF

BP

LI

M

MO

MT

MV

MVC

MVCO

MVFR

IP

IR

ISC

IV

IVFZ

L

LFR

LFZ

FE

FRT

I

I1..2..3..

IA

IC

ID

IE

EV

EVA

EVC

EVF

EVL

EVP

FA

FD

Door switch

Line switch

Warning light-freezing switch

Fan-motor switch

Freezer fan-motor switch

Line

Fridge lamp

Freezer lamp

Lighting lamp

Mass/Eart symbol

Terminal board

Timer motor

Fan motor

Compressor fan motor

Compressor compartment fan

Fan motor fridge

Fan motor freezer

Neutral

PTC relay

Aquastop electrovalve

Buzzer

Blocco Cesto

Terminal board contact, motor fan and dryer

Buzzer

Condensator

Condensator

Switching device

Electro-Valve Cold Water / Bleach

Electro-Valve Cold Water / Wash

Electro-Valve Cold Water / Prewash

Exclude Heating Element

Thermostat disactivation

Electrovalve

Dryer electrovalve

Hot water electrovalve

Elettrovalvola acqua fredda

Wash electrovalve

Pre Wash electrovalve

Antijamming filter

Delicate drying cycle thermostat

Strong drying cycle thermostat

Thermofusible Heating Element

Inverter

Switches/switching devices

Switch On/Off

Switch N.C. - 1/2 Load

Switch display

Water Saving Device

PM

PR

PS

R

P2

PA

PB

PL

THR

TP

TR

Mzbn/MTA

N

NC

P

P1

TA1

TA2

TC

TF

THA

THC

THDF

THI

SDC

SL

SND1

SND2

SND3

SND4

SND5

T

TB

TC

TFL

TG

ST

SV

T

TA

RE

RR

RV

Ras/RA

S

SL

SO

SR

CONTROL CARD DIAGRAM

Line warning

SONDE VERDAMPFER KUEHLSCHRANK

SONDELUFT FREEZER

AIR-PROBE REFRIGERATOR

Sonda evaporator freezer

SONDA ARIA FREEZER VANO

Erden

Open thermo actuator

Closed thermo actuator

Turbocooling

Fuse-thermic

Allarm thermostat

Freezer thermostat

Refrigerator shackler thermostat

Thermostat switch

Adjustable thermostat

Thermoprotector

Transformer zbn timer motor

Neutral or Terminal Board

Spin cycle exclusion

Pressure switch

1st level pressure cut-off switch

2nd level pressure cut-off switch

High speed potentiometer

Low speed potentiometer

Pure Wool

Motor Thermoprotector

Timer programmer or Pressure switch

Drain pump

Heating element

Relay

Heating element

Speed regulator

Dryer heating element

LED

Line LED

Door LED

Heating LED

Temperature selector

Speed Selector for Spin

Timer contacts

Drying timer contacts

Low Temperature Thermostat

Spider wheel earth

Flange earth

Main earth mod.TNFP3303TEL page 27

MO

MP

MR

MT

M

MC

MI

ML

MV

MV -Ras

L

LB

LN

LS

IF

IP

IR

IS

Switch - Spin Reduction

Door switch

Line switch

Water-stop

Line or Lamp

Low Level

Normal Level

Pilot lamp

Earth-symbol

Spin cycle motor

MOTOR WITH PULLEY

Wash cycle motor

Terminal Board

Door dip-switch

Thermal Lock

Timer motor

Motor fan

Dryer heating element

TMP

TMS

TP

TPS

TR

TS

TT

TTH

TV

ZBN

TH

TH1

TH2

TH3

THF

THR

TM

TMB

Thermostat

1st temperature thermostat

2nd temperature thermostat

3rd temperature thermostat

Operating thermostat

Adjustable thermostat

Motor earth

Main cabinet earth

Motor thermal protector

Thermostop

Thermal protector

Drain pump earth

Heating element earth

Safety thermostat

Timer earthing connection

Earthing Thermostat

Tank earth

Timer mod.TNFP3303TEL page 28

Electric schemes and links

Cod. 513009b mod.TNFP3303TEL page 29

CO

EV

FA

IDS

IEC

IEFR

IETH

ILFR

ILFZ

ILI

M

MO

MT

MV

MVCO

BZ

C

CM

L

LFR

LFZ

LI

IP

IR

ISC

IV

CM

CO

FA

IDS

ILFR

ILFZ

ILI

Legend

Legend: 513009b

Running capacitor

Compressor

Radio anti-trouble filter

Schackler with warning

Push-button for fridge lamp/fan

Push-button for freezer lamp/fan

Lamp switch

Door switch

Line switch

Warning light-freezing switch

Fan-motor switch

Line

Fridge lamp

Freezer lamp

Lighting lamp

Mass/Eart symbol

Terminal board

Timer motor

Fan motor

Compressor compartment fan

Audio freezer alarm

Surge Capacitor

Running capacitor

Compressor

Electrovalve

Radio anti-trouble filter

Schackler with warning

ON OFF loads switch

ON OFF refrigerator switch

Thermostat exclusion

Push-button for fridge lamp/fan

Push-button for freezer lamp/fan

Lamp switch

RFZ

RH

RS

RS1

RS2

RS3

RS4

RTA

SA

SC

T

TC

TF

THI

THR

R

RA

RAN

RS

RS1

RS2

SDC

SL

SND1

SND2

SND3

N

PTC

R

RA

RAN

RFZ

RH

Neutral

PTC relay

Heating resistance

Ammetrical relay

Heating element condensation

Heating element condensation freezer

Thermal relay

Defrosting resistance

Defrosting resistance no-frost evaporator

Defrosting resistance no-frost gutter

CONTROL CARD DIAGRAM

Line warning

PROBE REFRIGERATOR EVAP.

AIR-PROBE FREEZER

AIR-PROBE REFRIGERATOR

Erden

Turbocooling

Fuse-thermic

Thermostat switch

Adjustable thermostat

Heating resistance

Ammetrical relay

Heating element condensation

Heating element condensation freezer

Thermal relay

Defrosting resistance

No frost evaporator resistance

No frost drip pan resistance

Defrosting resistance

Defrosting resistance

Thermo actuator defrosting resistance

Allarm warning

Freezing warning mod.TNFP3303TEL page 30

C

CA

DV

EF/CL

EF/L

EF/P

ER

ET

MVFZ

N

PTC

AQS

B

BC

BF

BP

LI

M

MO

MT

MV

MVC

MVCO

MVFR

IP

IR

ISC

IV

IVFZ

L

LFR

LFZ

FE

FRT

I

I1..2..3..

IA

IC

ID

IE

EV

EVA

EVC

EVF

EVL

EVP

FA

FD

Door switch

Line switch

Warning light-freezing switch

Fan-motor switch

Freezer fan-motor switch

Line

Fridge lamp

Freezer lamp

Lighting lamp

Mass/Eart symbol

Terminal board

Timer motor

Fan motor

Compressor fan motor

Compressor compartment fan

Fan motor fridge

Fan motor freezer

Neutral

PTC relay

Aquastop electrovalve

Buzzer

Blocco Cesto

Terminal board contact, motor fan and dryer

Buzzer

Condensator

Condensator

Switching device

Electro-Valve Cold Water / Bleach

Electro-Valve Cold Water / Wash

Electro-Valve Cold Water / Prewash

Exclude Heating Element

Thermostat disactivation

Electrovalve

Dryer electrovalve

Hot water electrovalve

Elettrovalvola acqua fredda

Wash electrovalve

Pre Wash electrovalve

Antijamming filter

Delicate drying cycle thermostat

Strong drying cycle thermostat

Thermofusible Heating Element

Inverter

Switches/switching devices

Switch On/Off

Switch N.C. - 1/2 Load

Switch display

Water Saving Device

PM

PR

PS

R

P2

PA

PB

PL

THR

TP

TR

Mzbn/MTA

N

NC

P

P1

TA1

TA2

TC

TF

THA

THC

THDF

THI

SDC

SL

SND1

SND2

SND3

SND4

SND5

T

TB

TC

TFL

TG

ST

SV

T

TA

RE

RR

RV

Ras/RA

S

SL

SO

SR

CONTROL CARD DIAGRAM

Line warning

SONDE VERDAMPFER KUEHLSCHRANK

SONDELUFT FREEZER

AIR-PROBE REFRIGERATOR

Sonda evaporator freezer

SONDA ARIA FREEZER VANO

Erden

Open thermo actuator

Closed thermo actuator

Turbocooling

Fuse-thermic

Allarm thermostat

Freezer thermostat

Refrigerator shackler thermostat

Thermostat switch

Adjustable thermostat

Thermoprotector

Transformer zbn timer motor

Neutral or Terminal Board

Spin cycle exclusion

Pressure switch

1st level pressure cut-off switch

2nd level pressure cut-off switch

High speed potentiometer

Low speed potentiometer

Pure Wool

Motor Thermoprotector

Timer programmer or Pressure switch

Drain pump

Heating element

Relay

Heating element

Speed regulator

Dryer heating element

LED

Line LED

Door LED

Heating LED

Temperature selector

Speed Selector for Spin

Timer contacts

Drying timer contacts

Low Temperature Thermostat

Spider wheel earth

Flange earth

Main earth mod.TNFP3303TEL page 31

MO

MP

MR

MT

M

MC

MI

ML

MV

MV -Ras

L

LB

LN

LS

IF

IP

IR

IS

Switch - Spin Reduction

Door switch

Line switch

Water-stop

Line or Lamp

Low Level

Normal Level

Pilot lamp

Earth-symbol

Spin cycle motor

MOTOR WITH PULLEY

Wash cycle motor

Terminal Board

Door dip-switch

Thermal Lock

Timer motor

Motor fan

Dryer heating element

TMP

TMS

TP

TPS

TR

TS

TT

TTH

TV

ZBN

TH

TH1

TH2

TH3

THF

THR

TM

TMB

Thermostat

1st temperature thermostat

2nd temperature thermostat

3rd temperature thermostat

Operating thermostat

Adjustable thermostat

Motor earth

Main cabinet earth

Motor thermal protector

Thermostop

Thermal protector

Drain pump earth

Heating element earth

Safety thermostat

Timer earthing connection

Earthing Thermostat

Tank earth

Timer mod.TNFP3303TEL page 32

Electric schemes and links

Cod. 513017b mod.TNFP3303TEL page 33

CO

EV

FA

IDS

IEC

IEFR

IETH

ILFR

ILFZ

ILI

M

MO

MT

MV

MVCO

BZ

C

CM

L

LFR

LFZ

LI

IP

IR

ISC

IV

CM

CO

FA

IDS

ILFR

ILFZ

ILI

Legend

Legend: 513017b

Running capacitor

Compressor

Radio anti-trouble filter

Schackler with warning

Push-button for fridge lamp/fan

Push-button for freezer lamp/fan

Lamp switch

Door switch

Line switch

Warning light-freezing switch

Fan-motor switch

Line

Fridge lamp

Freezer lamp

Lighting lamp

Mass/Eart symbol

Terminal board

Timer motor

Fan motor

Compressor compartment fan

Audio freezer alarm

Surge Capacitor

Running capacitor

Compressor

Electrovalve

Radio anti-trouble filter

Schackler with warning

ON OFF loads switch

ON OFF refrigerator switch

Thermostat exclusion

Push-button for fridge lamp/fan

Push-button for freezer lamp/fan

Lamp switch

RFZ

RH

RS

RS1

RS2

RS3

RS4

RTA

SA

SC

T

TC

TF

THI

THR

R

RA

RAN

RS

RS1

RS2

SDC

SL

SND1

SND2

SND3

N

PTC

R

RA

RAN

RFZ

RH

Neutral

PTC relay

Heating resistance

Ammetrical relay

Heating element condensation

Heating element condensation freezer

Thermal relay

Defrosting resistance

Defrosting resistance no-frost evaporator

Defrosting resistance no-frost gutter

CONTROL CARD DIAGRAM

Line warning

PROBE REFRIGERATOR EVAP.

AIR-PROBE FREEZER

AIR-PROBE REFRIGERATOR

Erden

Turbocooling

Fuse-thermic

Thermostat switch

Adjustable thermostat

Heating resistance

Ammetrical relay

Heating element condensation

Heating element condensation freezer

Thermal relay

Defrosting resistance

No frost evaporator resistance

No frost drip pan resistance

Defrosting resistance

Defrosting resistance

Thermo actuator defrosting resistance

Allarm warning

Freezing warning mod.TNFP3303TEL page 34

C

CA

DV

EF/CL

EF/L

EF/P

ER

ET

MVFZ

N

PTC

AQS

B

BC

BF

BP

LI

M

MO

MT

MV

MVC

MVCO

MVFR

IP

IR

ISC

IV

IVFZ

L

LFR

LFZ

FE

FRT

I

I1..2..3..

IA

IC

ID

IE

EV

EVA

EVC

EVF

EVL

EVP

FA

FD

Door switch

Line switch

Warning light-freezing switch

Fan-motor switch

Freezer fan-motor switch

Line

Fridge lamp

Freezer lamp

Lighting lamp

Mass/Eart symbol

Terminal board

Timer motor

Fan motor

Compressor fan motor

Compressor compartment fan

Fan motor fridge

Fan motor freezer

Neutral

PTC relay

Aquastop electrovalve

Buzzer

Blocco Cesto

Terminal board contact, motor fan and dryer

Buzzer

Condensator

Condensator

Switching device

Electro-Valve Cold Water / Bleach

Electro-Valve Cold Water / Wash

Electro-Valve Cold Water / Prewash

Exclude Heating Element

Thermostat disactivation

Electrovalve

Dryer electrovalve

Hot water electrovalve

Elettrovalvola acqua fredda

Wash electrovalve

Pre Wash electrovalve

Antijamming filter

Delicate drying cycle thermostat

Strong drying cycle thermostat

Thermofusible Heating Element

Inverter

Switches/switching devices

Switch On/Off

Switch N.C. - 1/2 Load

Switch display

Water Saving Device

PM

PR

PS

R

P2

PA

PB

PL

THR

TP

TR

Mzbn/MTA

N

NC

P

P1

TA1

TA2

TC

TF

THA

THC

THDF

THI

SDC

SL

SND1

SND2

SND3

SND4

SND5

T

TB

TC

TFL

TG

ST

SV

T

TA

RE

RR

RV

Ras/RA

S

SL

SO

SR

CONTROL CARD DIAGRAM

Line warning

SONDE VERDAMPFER KUEHLSCHRANK

SONDELUFT FREEZER

AIR-PROBE REFRIGERATOR

Sonda evaporator freezer

SONDA ARIA FREEZER VANO

Erden

Open thermo actuator

Closed thermo actuator

Turbocooling

Fuse-thermic

Allarm thermostat

Freezer thermostat

Refrigerator shackler thermostat

Thermostat switch

Adjustable thermostat

Thermoprotector

Transformer zbn timer motor

Neutral or Terminal Board

Spin cycle exclusion

Pressure switch

1st level pressure cut-off switch

2nd level pressure cut-off switch

High speed potentiometer

Low speed potentiometer

Pure Wool

Motor Thermoprotector

Timer programmer or Pressure switch

Drain pump

Heating element

Relay

Heating element

Speed regulator

Dryer heating element

LED

Line LED

Door LED

Heating LED

Temperature selector

Speed Selector for Spin

Timer contacts

Drying timer contacts

Low Temperature Thermostat

Spider wheel earth

Flange earth

Main earth mod.TNFP3303TEL page 35

MO

MP

MR

MT

M

MC

MI

ML

MV

MV -Ras

L

LB

LN

LS

IF

IP

IR

IS

Switch - Spin Reduction

Door switch

Line switch

Water-stop

Line or Lamp

Low Level

Normal Level

Pilot lamp

Earth-symbol

Spin cycle motor

MOTOR WITH PULLEY

Wash cycle motor

Terminal Board

Door dip-switch

Thermal Lock

Timer motor

Motor fan

Dryer heating element

TMP

TMS

TP

TPS

TR

TS

TT

TTH

TV

ZBN

TH

TH1

TH2

TH3

THF

THR

TM

TMB

Thermostat

1st temperature thermostat

2nd temperature thermostat

3rd temperature thermostat

Operating thermostat

Adjustable thermostat

Motor earth

Main cabinet earth

Motor thermal protector

Thermostop

Thermal protector

Drain pump earth

Heating element earth

Safety thermostat

Timer earthing connection

Earthing Thermostat

Tank earth

Timer mod.TNFP3303TEL page 36

Electric schemes and links

Cod. 513022b mod.TNFP3303TEL page 37

CO

EV

FA

IDS

IEC

IEFR

IETH

ILFR

ILFZ

ILI

M

MO

MT

MV

MVCO

BZ

C

CM

L

LFR

LFZ

LI

IP

IR

ISC

IV

CM

CO

FA

IDS

ILFR

ILFZ

ILI

Legend

Legend: 513022b

Running capacitor

Compressor

Radio anti-trouble filter

Schackler with warning

Push-button for fridge lamp/fan

Push-button for freezer lamp/fan

Lamp switch

Door switch

Line switch

Warning light-freezing switch

Fan-motor switch

Line

Fridge lamp

Freezer lamp

Lighting lamp

Mass/Eart symbol

Terminal board

Timer motor

Fan motor

Compressor compartment fan

Audio freezer alarm

Surge Capacitor

Running capacitor

Compressor

Electrovalve

Radio anti-trouble filter

Schackler with warning

ON OFF loads switch

ON OFF refrigerator switch

Thermostat exclusion

Push-button for fridge lamp/fan

Push-button for freezer lamp/fan

Lamp switch

RFZ

RH

RS

RS1

RS2

RS3

RS4

RTA

SA

SC

T

TC

TF

THI

THR

R

RA

RAN

RS

RS1

RS2

SDC

SL

SND1

SND2

SND3

N

PTC

R

RA

RAN

RFZ

RH

Neutral

PTC relay

Heating resistance

Ammetrical relay

Heating element condensation

Heating element condensation freezer

Thermal relay

Defrosting resistance

Defrosting resistance no-frost evaporator

Defrosting resistance no-frost gutter

CONTROL CARD DIAGRAM

Line warning

PROBE REFRIGERATOR EVAP.

AIR-PROBE FREEZER

AIR-PROBE REFRIGERATOR

Erden

Turbocooling

Fuse-thermic

Thermostat switch

Adjustable thermostat

Heating resistance

Ammetrical relay

Heating element condensation

Heating element condensation freezer

Thermal relay

Defrosting resistance

No frost evaporator resistance

No frost drip pan resistance

Defrosting resistance

Defrosting resistance

Thermo actuator defrosting resistance

Allarm warning

Freezing warning mod.TNFP3303TEL page 38

C

CA

DV

EF/CL

EF/L

EF/P

ER

ET

MVFZ

N

PTC

AQS

B

BC

BF

BP

LI

M

MO

MT

MV

MVC

MVCO

MVFR

IP

IR

ISC

IV

IVFZ

L

LFR

LFZ

FE

FRT

I

I1..2..3..

IA

IC

ID

IE

EV

EVA

EVC

EVF

EVL

EVP

FA

FD

Door switch

Line switch

Warning light-freezing switch

Fan-motor switch

Freezer fan-motor switch

Line

Fridge lamp

Freezer lamp

Lighting lamp

Mass/Eart symbol

Terminal board

Timer motor

Fan motor

Compressor fan motor

Compressor compartment fan

Fan motor fridge

Fan motor freezer

Neutral

PTC relay

Aquastop electrovalve

Buzzer

Blocco Cesto

Terminal board contact, motor fan and dryer

Buzzer

Condensator

Condensator

Switching device

Electro-Valve Cold Water / Bleach

Electro-Valve Cold Water / Wash

Electro-Valve Cold Water / Prewash

Exclude Heating Element

Thermostat disactivation

Electrovalve

Dryer electrovalve

Hot water electrovalve

Elettrovalvola acqua fredda

Wash electrovalve

Pre Wash electrovalve

Antijamming filter

Delicate drying cycle thermostat

Strong drying cycle thermostat

Thermofusible Heating Element

Inverter

Switches/switching devices

Switch On/Off

Switch N.C. - 1/2 Load

Switch display

Water Saving Device

PM

PR

PS

R

P2

PA

PB

PL

THR

TP

TR

Mzbn/MTA

N

NC

P

P1

TA1

TA2

TC

TF

THA

THC

THDF

THI

SDC

SL

SND1

SND2

SND3

SND4

SND5

T

TB

TC

TFL

TG

ST

SV

T

TA

RE

RR

RV

Ras/RA

S

SL

SO

SR

CONTROL CARD DIAGRAM

Line warning

SONDE VERDAMPFER KUEHLSCHRANK

SONDELUFT FREEZER

AIR-PROBE REFRIGERATOR

Sonda evaporator freezer

SONDA ARIA FREEZER VANO

Erden

Open thermo actuator

Closed thermo actuator

Turbocooling

Fuse-thermic

Allarm thermostat

Freezer thermostat

Refrigerator shackler thermostat

Thermostat switch

Adjustable thermostat

Thermoprotector

Transformer zbn timer motor

Neutral or Terminal Board

Spin cycle exclusion

Pressure switch

1st level pressure cut-off switch

2nd level pressure cut-off switch

High speed potentiometer

Low speed potentiometer

Pure Wool

Motor Thermoprotector

Timer programmer or Pressure switch

Drain pump

Heating element

Relay

Heating element

Speed regulator

Dryer heating element

LED

Line LED

Door LED

Heating LED

Temperature selector

Speed Selector for Spin

Timer contacts

Drying timer contacts

Low Temperature Thermostat

Spider wheel earth

Flange earth

Main earth mod.TNFP3303TEL page 39

MO

MP

MR

MT

M

MC

MI

ML

MV

MV -Ras

L

LB

LN

LS

IF

IP

IR

IS

Switch - Spin Reduction

Door switch

Line switch

Water-stop

Line or Lamp

Low Level

Normal Level

Pilot lamp

Earth-symbol

Spin cycle motor

MOTOR WITH PULLEY

Wash cycle motor

Terminal Board

Door dip-switch

Thermal Lock

Timer motor

Motor fan

Dryer heating element

TMP

TMS

TP

TPS

TR

TS

TT

TTH

TV

ZBN

TH

TH1

TH2

TH3

THF

THR

TM

TMB

Thermostat

1st temperature thermostat

2nd temperature thermostat

3rd temperature thermostat

Operating thermostat

Adjustable thermostat

Motor earth

Main cabinet earth

Motor thermal protector

Thermostop

Thermal protector

Drain pump earth

Heating element earth

Safety thermostat

Timer earthing connection

Earthing Thermostat

Tank earth

Timer mod.TNFP3303TEL page 40

advertisement

Key Features

  • No-frost freezer
  • Spacious refrigerator compartment
  • Variety of shelves and drawers
  • Easy-to-use control panel
  • Variety of settings

Frequently Answers and Questions

What is the difference between the old and new freezer evaporator?
The new freezer evaporator is designed to run quieter than the old type. It has a ventilated evaporator with a lower input and output pipe position and a reduced delivery pipe diameter. The new evaporator can be used to replace the old type, but you will need to re-make the fixing holes in the freezer cell.
How do I force a freezer defrosting cycle?
To activate a forced defrosting cycle, first check that fast freezing is not ON. Then, open the freezer door and hold down the alarm pushbutton until a beep signal is given. This indicates that the forced defrost command has been accepted.
What does the -24°C LED (or SUPER LED) indicate?
The -24°C LED (or SUPER LED) indicates that the fast freezing feature is ON. It switches on with a delay after the start of the freezing cycle and stays ON for a few minutes after the freezer returns to normal operation.
What is the purpose of the new eutectic packet?
The new eutectic packet does not contain methylene blue and has a new container and radiating surface. It is fixed to the radiating surface with four stainless steel screws.

Related manuals

Download PDF

advertisement