VWR Microplate Shaker Instruction Manual
VWR Microplate Shaker: Compact and versatile, this shaker offers reliable shaking for microplates or microtubes in research laboratories, universities, and industrial settings. Its user-friendly interface features a digital display for precise speed and time adjustments, allowing for reproducible shaking conditions. The unit's sturdy construction and smooth operation ensure safe and efficient mixing for various applications.
Advertisement
Advertisement
Instruction Manual
Mini Shaker
Microplate Shaker
P ackage c ontents
Mini Shaker or Microplate Shaker
Non-skid rubber mat (Mini Shaker only)
92” (234cm) detachable power cord
Instruction manual
Package Contents
Warranty
Installation
Maintenance & Servicing t able of
c ontents
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
Environmental Conditions
Safety Instructions
Standards & Regulations
Control Panel
Mini Shaker
Microplate Shaker
Operating Instructions
Troubleshooting
Replacement Parts
Accessories
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
5-6
7-8
9-10
10
11-12
13-14
3
4
2
3
2
2
1
1
W arranty
Manufacturer warrants this product to be free from defects in material and workmanship when used under normal conditions for five (5) years. Register your equipment or instrument online at www.
vwrsp.com/warranty for US residents or www.vwrcanlab.com/warranty for Canadian residents. For your reference, make a note of the serial number, date of purchase and supplier here.
Serial No.:
Supplier:
Date of Purchase:
1
I nstallatIon
Upon receiving the VWR Mini/Microplate Shaker, check to ensure that no damage has occurred during shipment. It is important that any damage that occurred in transport is detected at the time of unpacking. If you do find such damage the carrier must be notified immediately.
After unpacking, place the Mini/Microplate Shaker on a level bench or table, away from explosive vapors. Secure to an immovable work surface by pressing down on the four (4) corners of the unit, creating a strong suction to the work surface
(do not place on a bench mat). Ensure that the surface on which the unit is placed will withstand typical heat produced by the unit. Always place the unit on a sturdy work surface.
The Mini/Microplate Shaker is supplied with a power cord that is inserted into the
IEC connector on the back of the unit first, then it can be plugged into a properly grounded outlet. The 120V unit plugs into a 120 volt, 50/60 Hz source. The 230V unit plugs into a 230 volt, 50/60 Hz source.
M aIntenance & s ervIcIng
The Mini/Microplate Shaker is built for long, trouble-free, dependable service.
No lubrication or other technical user maintenance is required. However at least every three (3) months you should:
• Unplug the unit.
• Remove any accumulated dirt from the base and tray.
• Check all accessible items to make sure they are properly tightened.
The unit should be given the care normally required for any electrical appliance.
Avoid wetting or unnecessary exposure to fumes. Spills should be removed promptly.
do not use a cleaning agent or solvent on the front panel which is abrasive or harmful to plastics, nor one which is flammable. Always ensure the power is disconnected from the unit prior to any cleaning. If the unit ever requires service, contact your VWR representative.
e nvIronMental
c ondItIons
operating Conditions: Indoor use only.
* For use in CO 2 environments, incubators or cold rooms.
* Temperature: -10 to 60°C (14 to 140°F).
Humidity:
Altitude: maximum 80% relative humidity, non-condensing
0 to 6,562 ft (2000 M) above sea level non-operating Storage:
* Temperature: -20 to 65°C (-4 to 149°F)
Humidity: maximum 80% relative humidity, non-condensing
Installation Category II and Pollution Degree 2 in accordance with IEC 664.
* Avoid cold starts: Unit is not designed to start after being in a cold room environment. Bring unit into cold room from a room temperature environment, operate and remove unit from cold room as soon as operation is complete.
2
s afety
I nstructIons
Please read the entire instruction manual before operating the Mini/
Microplate Shaker.
WArning! do not use the Mini/Microplate Shaker in a hazardous atmosphere or with hazardous materials for which the unit was not designed. Also, the user should be aware that the protection provided by the equipment may be impaired if used with accessories not provided or recommended by the manufacturer, or used in a manner not specified by the manufacturer.
Always operate unit on a level surface for best performance and maximum safety.
do not lift unit by the tray.
CAution! To avoid electrical shock, completely cut off power to the unit by disconnecting the power cord from the unit or unplug from the wall outlet. Disconnect unit from the power supply prior to maintenance and servicing.
Spills should be removed promptly. do not immerse the unit for cleaning.
do not operate the unit if it shows signs of electrical or mechanical damage.
Earth Ground - Protective Conductor Terminal
Alternating Current s tandards
& r egulatIons
Henry Troemner LLC hereby declares under it’s sole responsibility that the construction of this product conforms in accordance with the following standards:
Safety standards:
IEC 61010-1
IEC
Safety requirements for electrical equipment for measurement, control and laboratory use. Part I:
General Requirements.
equipment for mixing and stirring.
UL Std. No. 61010-1
CSA/CAN C22.2 No. 0-M91
CSA/CAN C22.2 No. 61010-1-04
EMC standards:
FCC-B EN55022-B
EN6100-3-3 EN6100-4-5
EN61000-4-2 EN61000-4-3
EN61000-4-4 EN61000-4-6
EN61000-4-11 EN61326-1 Class A
Associated Eu guidelines:
EMC directive 2004/108/EC
RoHS directive 2011/65/EU
LVD directive 2006/95/EC
3
B.
E.
d.
C.
F.
c ontrol
P anel
The front panel of the Mini/Microplate Shaker contains all the controls and displays needed to operate the unit.
A. Standby button/standby indicator light: The standby indicator light will illuminate when the unit is plugged in. The unit will be in standby mode. Press the standby button to activate the speed and time functions. The standby indicator light will shut off and the speed display and time displays will illuminate. Press the standby button again and the unit will once again be in standby mode.
B. Speed display: Displays the speed of the shaker. C. Up/down arrows for setpoint control. On/off button starts/stops shaking function. d. The speed indicator light will be illuminated when the unit is shaking.
A.
E. time display: Displays accumulated time (continuous mode) or how much time is remaining (timed mode). The display range is from 0 to 9,999 minutes in one (1) second increments. The display will indicate minutes and seconds until the timer reaches 99 minutes and 59 seconds (99:59), then the display will automatically display minutes up to 9,999. F. Up/down arrows for set-point control. On/ off button starts/stops the time function.
4
M
InI
s haker
s
PecIfIcatIons
5
Mini Shaker with plasticware
overall dimensions (L x W x H):
tray dimensions (L x W):
Electrical (50/60 Hz):
Fuses:
Speed range:
Speed accuracy:
timer:
orbit:
Maximum weight capacity:
Controls:
tray material:
Ship weight:
17 x 11 x 4”
(43.2 x 27.9 x 10.2cm)
11.75 x 8.75”
(29.9 x 22.2cm)
120 volts, 5 amps, 25 watts
230 volts, 5 amps, 25 watts
5mm x 20mm, 5 amp quick acting
100 to 1200rpm
±2%
1 second to 9999 minutes
(increased in 1 second increments)
0.125” (3mm)
~ 8lbs (3.6kg), up to 1000rpm
~ 5lbs (2.3kg), over 1000rpm see page 4
aluminum
25lbs (11.4kg)
M
InI
s haker
s et
-u
P
The Mini Shaker is supplied with a tray designed to hold a variety of accessories.
1. Flat containers can be shaken by placing them on the non-skid mat provided with the unit.
2. The tray also has mounting holes ready for use with flask/media bottle clamps or test tube racks. See below for tray configurations.
M
InI
s haker
t ray
c onfIguratIons
(35) 10mL Erlenmeyer Flask Clamps (20) 25mL Erlenmeyer Flask Clamps (15) 50mL Erlenmeyer Flask Clamps (12) 125mL Erlenmeyer Flask Clamps
(6) 250mL Erlenmeyer Flask Clamps (4) 500mL Erlenmeyer Flask Clamps (3) 500mL Media Bottle Clamps (2) Test Tube Racks
6
M
IcroPlate
s haker
s
PecIfIcatIons
7
Microplate Shaker with plasticware and 1.5 to 2mL Micro-Tube Rack
overall dimensions (L x W x H):
tray dimensions (L x W):
Electrical (50/60 Hz):
Fuses:
Speed range:
Speed accuracy:
timer:
orbit:
Capacity:
Controls:
tray material:
Ship weight:
17 x 11 x 4”
(43.2 x 27.9 x 10.2cm)
11 x 7.75”
(27.9 x 19.7cm)
120 volts, 5 amps, 25 watts
230 volts, 5 amps, 25 watts
5mm x 20mm, 5 amp quick acting
100 to 1200rpm
±2%
1 second to 9999 minutes
(increased in 1 second increments)
0.125” (3mm)
4 microplates or 2 Micro-Tube Racks see page 4
aluminum
25lbs (11.4kg)
M
IcroPlate
s haker
s et
-u
P
The Microplate Shaker is designed to hold two (2) or four (4) microplates, or two (2) Micro-Tube Racks.
1. Place two (2) microplates or deep well blocks diagonally on the tray, or place four (4) microplates or deep well blocks on the tray. The plates/blocks
do not have to be filled.
2. Place the corner of the plate/block under the spring located at each corner of the tray.
3. Slide plate/block into place. You are ready to use.
2.
3.
4.
M
IcroPlate
s haker
t ray
c onfIguratIons
(2) microplates (4) microplates
notE: The tray on the Microplate Shaker is not designed to hold flask clamps.
(2) Micro-Tube Racks
8
o
PeratIng
I nstructIons
The Mini/Microplate Shakers have been designed for the speed and time functions to work independently of one another. The speed can be reset without resetting the timer and the timer can be stopped and started without interrupting the shaking function.
1. getting ready:
a. Plug the power cord into a properly grounded outlet. The standby
indicator light will illuminate, verifying power to the unit.
b. Press the standby button to move the unit from standby mode. The standby indicator light will turn off and the speed and time displays will illuminate, displaying the previously used settings.
2. Setting speed:
a. Press the up/down arrows below the speed display until you reach
the desired speed. When you release the button, the display will
blink off and then on indicating the new set speed has been
accepted.
b.
light below the speed display will illuminate to indicate the shaking
function is in use and remain lit until shaking has ceased. The
microprocessor controlled ramping feature slowly increases speed
until the set-point is reached which helps to avoid splashing, and
provides excellent low end control.
c. Speed adjustments can be made without interrupting shaking by
using the up/down arrows below the speed display. After the
change has been made and you release the button, the display will
blink off and then on indicating the new set speed has been
accepted.
d. To stop the shaking function, press the on/off button below the
speed display. The speed indicator light will turn off.
9
3. Setting time to zero (0:00) and continuous mode: Accumulated time.
a.
(3) seconds the display will indicate the previous set time.
b. Simultaneously press both the up and the down arrows, the display
will indicate zero (0:00). The unit time is now set to zero (0:00)
minutes. Alternately, you can use the up/down arrows to get to
zero (0:00).
c. Press the on/off button below the time display. The display will
indicate accumulated time. The up/down arrows will become inactive.
To stop timer, press the on/off button again. iMPortAnt: This will
not interrupt the shaking function. Press the on/off button below
the speed display to interrupt the shaking function.
d. To reset, press and hold the on/off button below the time display.
After three (3) seconds the display will indicate the previous set
time, which was zero (0:00).
4. Setting timed mode: Programmed time.
a. Press the up/down arrows below the time display until you reach
the desired time.
b. Start this function by pressing the on/off button below the time
display. The unit will run for the selected time, the up/down arrows
will become inactive while the timer is running. The unit will stop
shaking when time display reaches zero (0:00). Four (4) audible
beeps will indicate the count down function is complete. The time
display will default back to the set time. To repeat for the same time,
simply press the on/off button again.
o
PeratIng
I nstructIons
c. To interrupt an automatic timing cycle before it is completed, press
the on/off button below the time display. The display will flash off
and on to indicate the time function is on “hold”. iMPortAnt: This
will not interrupt the shaking function. Press the on/off button
below the speed display to interrupt the shaking function. Restart
the timer by pressing the on/off button below the time display.
Unit will continue counting down to zero (0:00). When the display
reaches zero (0:00), you will hear the four (4) audible beeps that
indicate the count down function is complete and the shaking
function will cease.
5. turning unit off:
a. To turn the unit off, press the standby button. The speed and time
displays will be blank, the standby indicator light will illuminate.
The Mini/Microplate Shaker should be kept in standby mode when
not in use. To completely cut off power to the unit, disconnect the
power cord form the unit or unplug from the wall outlet.
oPErAting tiPS
As a safety feature, a built-in program will shut power off to the motor if the tray is prevented from rotating, or the unit is overloaded beyond its recommended weight capacity.
Built-in memory maintains the last used speed and time settings during a power interruption.
t roubleshootIng
During operation, any rattling or ticking sounds may indicate a loose screw on the tray, a tray attachment or an accessory. All accessories should be sufficiently tightened in place before starting the unit.
Error Code
E04
Software test unit overloaded
Cause maximum load exceeded loose foot (suction cup) *
Press the standby button to clear this error. Be sure the load is within the maximum load capacity before restarting the unit. If the E04 error code persists, switch the unit off and contact your VWR representative for repairs.
Error Code
E03
Software test drive system failure
Cause ceased bearing drive belt broken mechanical obstruction loose foot (suction cup) *
Press the standby button to clear this error and remove the mechanical obstruction. If the E03 error persists the reason may be a ceased bearing or broken drive belt and should not be addressed by the end user. Switch the unit off and contact your VWR representative for repairs.
* In the event a foot (suction cup) has come loose from the bench top, the unit will register an errant E04 or EO3 error message due to the instability of the unit. Press the standby button to clear this error. Firmly press down on the four (4) corners of the unit, creating a strong suction to the work surface (do not place on bench mat). Press the standby button to resume operation.
10
M
InI
s haker
r ePlaceMent
P arts
2.
1.
3.
7.
6.
4.
5.
8.
10.
dESCriPtion
1. Front panel membrane switch
2. Tray
3. Display board
4. Belt
5. Motor
6. Motor transition board
7. Connection cable
8. IEC power entry module
9. Feet (suction cup)
10. Detachable 92” (234cm) power cord:
PArt nuMBEr
380704-00
580050-00
380780-00
580019-00
380712-00
380715-00
120V
380720-00
386122-00
545014-00
330100-00
EURO 330101-00
UK 330102-00
SWISS 330103-00
11
9.
M
IcroPlate
s haker
r ePlaceMent
P arts dESCriPtion
1. Front panel membrane switch
2. Tray assembly
3. Display board
4. Belt
5. Motor
6. Motor transition board
7. Connection cable
8. IEC power entry module
9. Feet (suction cup)
10. Detachable 92” (234cm) power cord:
PArt nuMBEr
380703-00
880761-00
380780-00
580019-00
380712-00
380715-00
120V
380720-00
386122-00
545014-00
330100-00
EURO 330101-00
UK 330102-00
SWISS 330103-00
1.
7.
3.
6.
4.
2.
5.
9.
8.
10.
12
a ccessorIes
tESt tuBE rACkS
d escrIPtIon
10 to 13mm Test Tube Rack
14 to 16mm Test Tube Rack
18 to 20mm Test Tube Rack
22 to 25mm Test Tube Rack
15mL Centrifuge Tube Rack
50mL Centrifuge Tube Rack
1.5 to 2mL Micro-Tube Rack t ube c aPacIty
63
48
35
24
35
12
70
P latforM c aPacIty
2
2
2
2
2
2
2 c at . n o .
12620-956
12620-958
12620-960
12620-962
11301-134
11301-136
12620-952 installation of test tube racks - Mini Shaker
1. Unit should be in standby mode.
2. Remove non-skid rubber mat.
3. Align the clip on the rack to the right side of the tray.
4. Line up the holes in the test tube rack to the holes in the tray. Using the
screws provided, hand tighten into place using a flathead screwdriver. do
not over tighten.
installation of 1.5 to 2mL Micro-tube rack - Microplate Shaker
1. Unit should be in standby mode.
2. Align the Micro-Tube Rack side-to-side on the tray.
3. Press the Micro-Tube Rack in place, you will hear the Micro-Tube Rack clip
into position. No mounting screws are required.
FLASk CLAMPS
d escrIPtIon
10mL Erlenmeyer Flask Clamp
25mL Erlenmeyer Flask Clamp
50mL Erlenmeyer Flask Clamp
125mL Erlenmeyer Flask Clamp
250mL Erlenmeyer Flask Clamp
500mL Erlenmeyer Flask Clamp
500mL Media Bottle Clamp
125mL Erlenmeyer Flask Clamp
250mL Erlenmeyer Flask Clamp
500mL Erlenmeyer Flask Clamp
M aterIal stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel
PVC
PVC
PVC
P latforM c aPacIty
35
20
15
12
6
4
3
12
6
4 c at . n o .
57018-775
57018-786
57018-797
57018-800
57018-811
57018-822
14215-236
97003-576
97003-578
97003-580 installation of Flask Clamps - Mini Shaker
1. Unit should be in standby mode.
2. Remove non-skid rubber mat.
3. Line up the hole(s) in the flask clamp to the hole(s) in the tray. Using the
screw(s) provided, hand tighten into place using a flathead screwdriver.
do not over tighten.
4. Insert flask/media bottle into clamp and wrap the spring around the neck
of the clamp to hold secure.
not for use with the Microplate Shaker.
13
a ccessorIes
univErSAL HArnESS
d escrIPtIon
Universal Harness
M
IcroPlate c aPacIty
2 or 4
P latforM c aPacIty
1 c at
. n o
.
12620-954 installation of universal Harness - Mini Shaker
1. Unit should be in standby mode.
2. Remove non-skid rubber mat.
3. Insert one band through the side of one “U” in the U-shaped cut-outs on the center post. Pull band through to secure to the U-shaped cut-out. Repeat for the three remaining bands.
4. After the bands are installed in the center post, line up the holes in center post with the two holes in middle of the tray. Using the screws provided, hand tighten into place using a flathead screwdriver. do not over tighten.
5. Place sample(s) on tray.
6. Stretch the harness bands over the sample(s) and then under each of the
bent-down corners of the tray.
not for use with the Microplate Shaker.
univErSAL PLAtForM
The Universal Platform has a non-skid rubber surface with adjustable clamping bars to accommodate various vessel types. Stainless steel construction.
d escrIPtIon
Universal Platform s Ize (l x W)
11.7 x 8.7”
(29.7 x 22.1cm)
P c latforM aPacIty
1 c at . n o .
12620-964 installation of universal Platform - Mini Shaker
1. Unit should be in standby mode.
2. Remove non-skid rubber mat.
3. Line up the holes in the Universal Platform to the holes in the tray. Using
the screws provided, hand tighten into place using a flathead screwdriver.
do not over tighten.
4. Add glassware. Adjust rollers by loosening each of the thumbscrews. Slide
the padded rollers to the desired position and retighten the thumbscrews.
not for use with the Microplate Shaker.
14
M anufactured by
:
HEnry troEMnEr LLC
201 Wolf Drive • PO Box 87 • Thorofare, NJ 08086-0087
Phone: 856-686-1600 • Fax: 856-686-1601 • E-mail: [email protected]
www.troemner.com
715054-00 (REV 6 - 8/14)
Advertisement