S0.2 Safety
1. Zero Energy State
ATTENTION: ZERO ENERGY STATE
To perform service, maintenance and repairs you must disconnect the RigMaster from its battery source. In the recommended installation configuration the RigMaster shares the battery bank with the vehicles main engine. After disconnecting the battery cables, check the battery posts inside the RigMaster engine cabinet to confirm there is no voltage to the auxiliary power unit (APU).
2. Safety Cover Switch
WARNING: SAFETY COVER SWITCH
It is critical that this safety cover switch is never deactivated or bypassed; failure to comply may result in serious injury.
The safety cover switch (figure S-1) is designed to prevent the RigMaster Power APU from starting when the engine cover is loose or has been removed. When the switch is in the closed position the cover is down. When the switch is open position the cover has been removed or is loose.
The switch is located at the front of the engines enclosure in the lower right hand corner.
Figure S-1
3. AutoStart Automatic Start/Stop Feature
WARNING: AUTOSTART FEATURE
Remember that a properly functioning RigMaster is capable of starting independently of its operator. If the AutoStart feature is enabled, battery voltage, temperature, and time of day can all cause the RigMaster’s engine to start. Please see the cabin controllers operating instructions for further information on the
AutoStart feature. You must deactivate this feature prior to refueling.
4. Engine Hoist Points
ATTENTION: ENGINE HOIST POINTS
The Perkins and CAT engines have hoist points that are useful for removal and reinstallation of the engine. Under no circumstances should the entire RigMaster
APU assembly be lifted by the engine hoist points as they are not intended to hold the increased weight of the engine with fluids, frame and other on-board equipment.
RigMaster
®
Service Manual Safety
5. Starting Aids
WARNING
Do not use any type of starting aids such as ether. Such use could result in an explosion and personal injury, and will render the APU warranty null and void.
6. Starting with the Cover Off
ATTENTION
Some installation or repair/diagnostic procedures require that the APU is started with the engine cover off. Do not deactivate or bypass the safety cover switch.
Instead, have another individual assist by manually holding the safety cover switch down in the closed position for the duration of the procedure.
7. Inspection of the Safety Systems
The safety systems on the RigMaster APU should be examined and tested at prior to performing any service work and at 50 hour intervals to ensure that they are in good condition and proper working order.
8. Safe Working Practices
Safe working practices are your responsibility. The use of protective safety equipment is mandatory when performing inspections, service, diagnostics and repairs on the
RigMaster APU. Follow your local regulations and guidelines regarding occupational health and safety.
9. Contact Us
If you do not fully understand this safety information contact RigMaster’s Technical
Support Department toll free at (888) 208–3101 before proceeding with the operation or service of this APU.