Service Manual TG 2000 Signal Generation Platform 070-9299-01

Add to my manuals
162 Pages

advertisement

Service Manual TG 2000 Signal Generation Platform 070-9299-01 | Manualzz
Service Manual
TG 2000
Signal Generation Platform
070-9299-01
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
Copyright Tektronix, Inc. All rights reserved.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price change privileges reserved.
Printed in the U.S.A.
Tektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Windows and Microsoft are registered trademarks of the Microsoft corporation.
WARRANTY
Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship
for a period of one (1) year from the date of shipment. If a product proves defective during this warranty period, Tektronix,
at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in
exchange for the defective product.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the
warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for
packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid.
Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the
Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any
other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate
maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting
from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair
damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction
caused by the use of non-Tektronix supplies; or d) to service a product that has been modified or integrated with other
products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO
REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO
THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE
LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE
OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH
DAMAGES.
Service Assurance
If you have not already purchased Service Assurance for this product, you may do so at any time during the product’s
warranty period. Service Assurance provides Repair Protection and Calibration Services to meet your needs.
Repair Protection extends priority repair services beyond the product’s warranty period; you may purchase up to three
years of Repair Protection.
Calibration Services provide annual calibration of your product, standards compliance and required audit documentation,
recall assurance, and reminder notification of scheduled calibration. Coverage begins upon registration; you may purchase
up to five years of Calibration Services.
Service Assurance Advantages
Priced well below the cost of a single repair or calibration
Avoid delays for service by eliminating the need for separate purchase authorizations from your company
Eliminates unexpected service expenses
For Information and Ordering
For more information or to order Service Assurance, contact your Tektronix representative and provide the information
below. Service Assurance may not be available in locations outside the United States of America.
Name
Company
Address
City, State, Postal code
Country
Phone
VISA or Master Card number and expiration
date or purchase order number
Repair Protection (1,2, or 3 years)
Calibration Services (1,2,3,4, or 5 years)
Instrument model and serial number
Instrument purchase date
Table of Contents
General Safety Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Safety Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vii
ix
xi
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Characteristics Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–1
1–1
1–2
1–3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–1
2–6
Block Level Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–1
Specifications
Operating Information
Theory of Operation
Performance Verification
Verification Interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Equipment Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verification Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–1
4–1
4–2
4–2
Adjustment Procedures
Equipment Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Self Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjustment Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5–1
5–2
5–2
5–3
Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspection and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
After Repair Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repackaging Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–1
6–3
6–4
6–4
Removal and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–9
Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–9
6–10
Troubleshooting Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–37
Equipment Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Troubleshooting Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fault Symptom Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting Flowcharts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–37
6–37
6–40
6–41
Maintenance
TG 2000 Signal Generation Platform Service Manual
i
Contents
Options
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–1
Replaceable Electrical Parts
Replaceable Electrical Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8–1
Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9–1
Mainframe Interconnect Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modules Interconnect Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9–1
9–1
Diagrams
Replaceable Mechanical Parts
Replaceable Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10–1
Parts Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Replaceable Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10–1
10–2
Index
ii
TG 2000 Signal Generation Platform Service Manual
Contents
List of Figures
Figure 2–1: Location of the rear-panel power connector
and configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–2: Location of the CPU configuration switch . . . . . . . . . . . .
Figure 2–3: Installing the rackmount hardware . . . . . . . . . . . . . . . . .
Figure 2–4: Installing the TG 2000 Platform mainframe
into the rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–5: Instrument front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–6: Browsed and selected display icons . . . . . . . . . . . . . . . . . .
Figure 2–7: Main display features . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–8: Module and test signal hierarchy . . . . . . . . . . . . . . . . . . .
Figure 2–9: Selecting the Save Signals to Disk source . . . . . . . . . . . . .
Figure 2–10: Selecting a Save Signals to Disk destination . . . . . . . . . .
Figure 2–11: Replacing test signals from disk . . . . . . . . . . . . . . . . . . .
Figure 2–12: Selecting the source signals to add from disk . . . . . . . . .
Figure 2–13: Add Signals window with source and destination
selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–14: Rear-panel connectors . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–15: RS–232 connector pin descriptions . . . . . . . . . . . . . . . . .
2–2
2–3
2–4
2–5
2–7
2–9
2–11
2–12
2–14
2–15
2–16
2–17
2–18
2–19
2–20
Figure 3–1: Simplified block diagram . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3–2: Block diagram of the clocks and frame reset signals . . . .
Figure 3–3: Comparison of module delay and system delay from
a reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3–4: Block diagram of module timing delay . . . . . . . . . . . . . . .
Figure 3–5: Block diagram of the AGL1 Reference timing delay . . .
3–5
3–6
3–6
Figure 4–1: Save Signals to Disk window . . . . . . . . . . . . . . . . . . . . . . .
Figure 4–2: New Directory window . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4–3: New directory named Test . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4–4: Equipment setup for verifying clock operation . . . . . . . .
4–3
4–4
4–4
4–9
Figure 5–1: Measuring the power supply voltages on the clock board
Figure 5–2: Locating parts on the clock board . . . . . . . . . . . . . . . . . . .
5–4
5–5
Figure 6–1: Placing the module in the protective wrapping . . . . . . . .
Figure 6–2: Placing the module in the shipping carton . . . . . . . . . . . .
6–5
6–6
TG 2000 Signal Generation Platform Service Manual
3–1
3–4
iii
Contents
Figure 6–3: Placing the TG 2000 Platform mainframe in the
shipping carton . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–4: Top cover removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–5: Removing the front-frame assembly . . . . . . . . . . . . . . . . .
Figure 6–6: Removing the front-panel board and display
module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–7: Disconnecting the LCD Display module and Front
Panel board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–8: Replacing the knob encoder . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–9: Replacing the airflow regulator . . . . . . . . . . . . . . . . . . . . .
Figure 6–10: Removing the floppy drive . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–11: Installing the floppy drive into the chassis . . . . . . . . . . .
Figure 6–12: Removing the floppy drive assembly shield . . . . . . . . . .
Figure 6–13: Location of the Power Supply module grounding strap
(SN B010391 and below only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–14: Removing the Power Supply module . . . . . . . . . . . . . . .
Figure 6–15: Removing the Power Supply module attaching
screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–16: Removing the Power Supply board . . . . . . . . . . . . . . . . .
Figure 6–17: Removing the Line Filter board . . . . . . . . . . . . . . . . . . .
Figure 6–18: Installing the fuse holder . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–19: Removing the CPU module floppy cable . . . . . . . . . . . .
Figure 6–20: Installing the CPU Memory board . . . . . . . . . . . . . . . . .
Figure 6–21: Removing the date/time clock from the CPU module . .
Figure 6–22: Installing the Clock board oscillator . . . . . . . . . . . . . . . .
Figure 6–23: Removing the Power Supply board fan . . . . . . . . . . . . .
Figure 6–24: Removing the Clock board fan . . . . . . . . . . . . . . . . . . . .
Figure 6–25: Removing the Backplane board . . . . . . . . . . . . . . . . . . .
Figure 6–26: Replacing the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–27: Instrument does not boot up properly . . . . . . . . . . . . . .
Figure 6–28: Measuring the power supply voltages on the
clock board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–29: Backlight does not illuminate . . . . . . . . . . . . . . . . . . . . .
Figure 6–30: Measuring the LCD Display module high voltage . . . . .
Figure 6–31: Front panel does not function . . . . . . . . . . . . . . . . . . . . .
Figure 6–32: Locked LED does not illuminate . . . . . . . . . . . . . . . . . . .
Figure 6–33: Floppy drive does not operate properly . . . . . . . . . . . . .
Figure 6–34: Instrument is hot or the fans do not operate . . . . . . . . .
Figure 6–35: Correct time is not stored . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–36: Signal noise in mainframe slots 9 and 10 . . . . . . . . . . . .
iv
6–7
6–11
6–12
6–13
6–14
6–15
6–16
6–17
6–19
6–20
6–21
6–22
6–22
6–24
6–25
6–27
6–28
6–29
6–30
6–32
6–33
6–34
6–35
6–36
6–41
6–42
6–42
6–43
6–43
6–44
6–44
6–45
6–46
6–46
TG 2000 Signal Generation Platform Service Manual
Contents
Figure 6–37: Instrument loses signal and operating memory during
rear-panel power off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–38: Measuring the battery charging circuit . . . . . . . . . . . . .
Figure 6–39: Front-panel knob does not function properly . . . . . . . .
6–47
6–48
6–48
Figure 9–1: Backplane board connections . . . . . . . . . . . . . . . . . . . . . .
Figure 9–2: CPU, Front Panel board, Power Supply board and
Line Filter connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9–3: Clock connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9–4: AGL1 module connections . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9–5: AVG1 module connections . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9–6: AWVG1 module connections . . . . . . . . . . . . . . . . . . . . . . .
Figure 9–7: BG1 module connections . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9–8: GP1 module connections . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9–9: DVG1 module connections (standard) . . . . . . . . . . . . . . .
Figure 9–10: DVG1 module connections (with Option S1 installed as
shipped) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9–3
9–4
9–4
9–5
9–5
9–6
9–6
9–7
Figure 10–1: Top cover and chassis assembly . . . . . . . . . . . . . . . . . . . .
Figure 10–2: Front panel, disk drive and display . . . . . . . . . . . . . . . . .
Figure 10–3: Disk drive assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 10–4: Power Supply module assembly . . . . . . . . . . . . . . . . . . .
Figure 10–5: CPU assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 10–6: Clock assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 10–7: Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10–6
10–8
10–10
10–12
10–14
10–16
10–18
TG 2000 Signal Generation Platform Service Manual
9–2
9–7
v
Contents
List of Tables
vi
Table 1–1: AC Power source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 1–2: Physical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 1–3: Environmental characteristics . . . . . . . . . . . . . . . . . . . . . .
Table 1–4: System clock and frame reset . . . . . . . . . . . . . . . . . . . . . . .
Table 1–5: Certifications and compliances . . . . . . . . . . . . . . . . . . . . . .
1–3
1–3
1–3
1–5
1–6
Table 2–1: AC power fuse requirements . . . . . . . . . . . . . . . . . . . . . . .
Table 2–2: Keypad definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2
2–8
Table 4–1: Test equipment required for verification . . . . . . . . . . . . . .
4–1
Table 5–1: Equipment List for adjustments
....................
5–1
Table 6–1: Tools required for module removal . . . . . . . . . . . . . . . . . .
Table 6–2: Removal and replacement procedure list . . . . . . . . . . . . .
Table 6–3: Equipment required for troubleshooting . . . . . . . . . . . . .
Table 6–4: CPU confidence test codes . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6–5: Fault symptom table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–9
6–10
6–37
6–40
6–40
Table 7–1: Power cord identification . . . . . . . . . . . . . . . . . . . . . . . . . .
7–1
TG 2000 Signal Generation Platform Service Manual
General Safety Summary
Review the following safety precautions to avoid injury and prevent damage to
this product or any products connected to it.
Only qualified personnel should perform service procedures.
To avoid potential hazards, use this product only as specified.
Injury Precautions
Use Proper Power Cord. To avoid fire hazard, use only the power cord specified
for this product.
Avoid Electric Overload. To avoid electric shock or fire hazard, do not apply a
voltage to a terminal that is outside the range specified for that terminal.
Ground the Product. This product is grounded through the grounding conductor
of the power cord. To avoid electric shock, the grounding conductor must be
connected to earth ground. Before making connections to the input or output
terminals of the product, ensure that the product is properly grounded.
Do Not Operate Without Covers. To avoid electric shock or fire hazard, do not
operate this product with covers or panels removed.
Use Proper Fuse. To avoid fire hazard, use only the fuse type and rating specified
for this product.
Do Not Operate in Wet/Damp Conditions. To avoid electric shock, do not operate
this product in wet or damp conditions.
Do Not Operate in an Explosive Atmosphere. To avoid injury or fire hazard, do not
operate this product in an explosive atmosphere.
Product Damage
Precautions
Use Proper Power Source. Do not operate this product from a power source that
applies more than the voltage specified.
Use Proper Voltage Setting. Before applying power, ensure that the line selector is
in the proper position for the power source being used.
Provide Proper Ventilation. To prevent product overheating, provide proper
ventilation.
Do Not Operate With Suspected Failures. If you suspect there is damage to this
product, have it inspected by qualified service personnel.
TG 2000 Signal Generation Platform Service Manual
vii
General Safety Summary
Symbols and Terms
Terms in this Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result
in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in
damage to this product or other property.
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the
marking.
WARNING indicates an injury hazard not immediately accessible as you read the
marking.
CAUTION indicates a hazard to property including the product.
Symbols on the Product. The following symbols may appear on the product:
DANGER
High Voltage
Certifications and
Compliances
viii
Protective Ground
(Earth) Terminal
ATTENTION
Refer to Manual
Double
Insulated
Refer to the specifications section for a listing of certifications and compliances
that apply to this product.
TG 2000 Signal Generation Platform Service Manual
Service Safety Summary
Only qualified personnel should perform service procedures. Read this Service
Safety Summary and the General Safety Summary before performing any service
procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this
product unless another person capable of rendering first aid and resuscitation is
present.
Disconnect Power. To avoid electric shock, disconnect the mains power by means
of the power cord or the rear-panel power switch.
Use Care When Servicing With Power On. Dangerous voltages or currents may
exist in this product. Disconnect power cord and test leads before removing
protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed connections.
TG 2000 Signal Generation Platform Service Manual
ix
Service Safety Summary
x
TG 2000 Signal Generation Platform Service Manual
Preface
You have purchased this optional service manual for the TG 2000 Platform
mainframe. You can also purchase service manuals for the modules. Each
module manual begins with a tab so that you can locate it after you add it to the
mainframe manual binder.
The user manuals are set up the same way as the service manuals. You should
receive a user manual with each mainframe or module ordered.
About This Manual
This manual contains information for servicing the TG 2000 Signal Generation
Platform to a module level. The information is designed only for qualified
service technicians, with moderate experience in analog circuits, digital circuits,
and television technology. This manual is composed of the following sections:
Specifications provides a basic product description followed by instrument
specifications tables.
Operating Information is designed to provide just enough operating
information for a service technician to be able to service the product. For
more details, refer to the user manual.
Theory of Operation is an overview of the main components of the platform,
describing general interactions with the modules.
Performance Verification contains procedures necessary to verify that the
mainframe components (Clock, Power Supply, and CPU) are meeting the
requirements listed in the Specifications.
Adjustments contains procedures to adjust the +5V power supply and the
oscillator.
Maintenance contains installation, removal and replacement, and troubleshooting instructions.
Options lists all available options for the mainframe.
Replaceable Electrical Parts for the module level are included in the
Replaceable Mechanical Parts list.
Diagrams contains interconnect diagrams showing the connections between
the mainframe and the modules.
Replaceable Mechanical Parts lists the part numbers for replacement parts
that you can order. Exploded view illustrations help you to identify the parts.
TG 2000 Signal Generation Platform Service Manual
xi
Preface
Contacting Tektronix
Product
Support
For application-oriented questions about a Tektronix measurement product, call toll free in North America:
1-800-TEK-WIDE (1-800-835-9433 ext. 2400)
6:00 a.m. – 5:00 p.m. Pacific time
Or contact us by e-mail:
[email protected]
For product support outside of North America, contact your
local Tektronix distributor or sales office.
Service
Support
Contact your local Tektronix distributor or sales office. Or visit
our web site for a listing of worldwide service locations.
http://www.tek.com
xii
For other
information
In North America:
1-800-TEK-WIDE (1-800-835-9433)
An operator will direct your call.
To write us
Tektronix, Inc.
P.O. Box 1000
Wilsonville, OR 97070-1000
TG 2000 Signal Generation Platform Service Manual
Specifications
This section contains the Product Description, which describes the product and
accessories, and the Characteristics Tables, which list the product specifications.
Product Description
The TG 2000 Signal Generation Platform provides multiformat, precision
television test signals for both analog and digital video standards. The physical
configuration is a mainframe with up to nine plug-in modules. Modules either
generate signals or provide special functions, such as genlock capability.
You can use included software (SDP2000 Signal Development Program) to
generate custom test signals, which you can store on a disk or transfer directly
into the memory of a generator module.
The TG 2000 Signal Generation Platform addresses the needs of research and
development, engineering, manufacturing test, and most operational environments.
These are some of the key features of the platform:
Modular architecture with up to nine generators or special function modules
Support of analog and digital environments for most component and
composite video signal formats
Reference generator performance level
Modules genlocked to external reference with the optional AGL1 Genlock
module
Included Microsoft Windows-based SDP2000 software to create new signals
Remote control, using RS-232 interface (or optional GPIB interface) and
SCPI command set
Full support of VM700A video measurement routines
Variable transmission parameters, such as jitter amplitude and frequency, for
serial digital formats using the DVG1 module with option S1
Variable signal parameters for some analog and digital format modules
Circle and text overlays on test signals for some modules
Simultaneous 525/60 and 625/50 signal generation
TG 2000 Signal Generation Platform Service Manual
1–1
Specifications
Moving signals for compression system testing
Programmable system clocks to support standard and custom formats
Flash EPROM allows easy upgrades to system software
Accessories
This section describes the key accessories for the TG 2000 Signal Generation
Platform. For a complete list of accessories and their Tektronix part numbers,
refer to the Replaceable Mechanical Parts list at the back of this manual.
BG1 Black Burst
Generator Module
The BG1 Generator module is supplied as a standard accessory. There are six
black burst signals to select from; the module provides the selected black burst
signal on the three rear-panel connectors. Additionally, the module can provide
one of the system clocks from its rear-panel clock output.
More than one BG1 Generator module can be added to the mainframe to provide
enough flexibility to meet virtually any system timing requirement. The BG1
Generator module can be removed without affecting system operation.
SDP2000 Signal
Development Program
The SDP2000 Signal Development Program is supplied as a standard accessory.
This program runs under Microsoft Windows 3.1 or higher. All features except the
parallel port are compatible with Windows NT. All features are compatible with
Windows 95.
You can use the SDP2000 program to create custom signals for the various
modules. You can use the remote interface or a disk to download the signals to
the module memory. Refer to the SDP2000 Signal Development Program User
Manual for information about using this program.
GPIB Card for SDP2000
Communications
The Tektronix S3FG210 is a GPIB–PCII/IIA interface card. It provides the type
of interface needed to operate the TG 2000 Signal Generation Platform when
performing GPIB communications with the SDP2000/TGCOMM software.
Accessory Kit
The accessory kit includes a Torx T-10 bit (needed to secure the modules), two
fuses, and a blank panel. The fuses support the two line voltage settings; see
Electrical Installation on page 2–1 for instructions. The blank panel fills the gap
when a module is removed.
Extender Board
1–2
The extender board is an optional accessory that you can order to use when
troubleshooting the TG 2000 Signal Generation Platform. The part number can
be found at the end of the Replaceable Mechanical Parts list.
TG 2000 Signal Generation Platform Service Manual
Specifications
Characteristics Tables
This section lists the electrical and environmental specifications for the TG 2000
Platform mainframe. For the specifications of a specific module, refer to the user
or service manual for that module.
Table 1–1: AC Power source
Characteristic
Performance requirement
Reference information
AC Source Voltage
115 V operation
87 VRMS to 132 VRMS
230 V operation
174 VRMS to 250 VRMS
Power Consumption
220 W line power typical
Fuse Rating
115V Operation
Slow blow, 6 AT
230 V Operation
Slow blow, 3 AT
Nominal Switching Frequency
100 kHz
Table 1–2: Physical dimensions
Characteristic
Description
Dimensions
Height:
Width:
Depth:
Weight1
Net Weight:
Shipping Weight:
5.25 in (13.34 cm)
19.0 in (48.26 cm); standard rack width
23 in (58.42 cm)
38 lbs (17.27 kg) typical
52 lbs (23.67 kg) typical
Table 1–3: Environmental characteristics
Characteristic
Performance requirement
Reference information
Temperature
1
2
Operating
32_ F to 104_ F (0_ C to 40_ C)
Nonoperating
–4 to +140_ F (–20 to +60_ C)2
Weight of the TG 2000 will vary depending on the number and type of generator or other modules installed.
Battery storage life is specified at 25_ C. At 60_ C, battery discharge accelerates, resulting in self discharge in less than
30 days.
TG 2000 Signal Generation Platform Service Manual
1–3
Specifications
Table 1–3: Environmental characteristics (cont.)
Characteristic
Performance requirement
Reference information
Altitude
Operating
To 15,000 feet (4572 meters)
Nonoperating
To 40,000 feet (12,203 meters)
Humidity
Operating
≤ 104_ F (≤ 40_ C ), up to 95% relative
humidity
Nonoperating
Up to 95% relative humidity
Heat Dissipation
220 Watts maximum for mainframe with
modules in all slots
Clearance for Cooling
For rack installation, allow standard side
cooling and 2 in (5 cm) rear clearance for
cables
For desktop use, allow 2 in (5 cm) side and
rear clearance
Bench Handling
1 drop of 2 inches of each edge for all
significant surfaces
Vibration
Operating
5-100 HZ g2/Hz APSD:
100-200 Hz Slope dB/Octave:
200-350 HZ g2/Hz APSD:
350-500 Hz Slope dB/Octave:
500 HZ g2/Hz APSD:
GRMS overall:
Time/Axis minutes:
0.00015
0
0.00015
–3
0.000105
0.27[0.24]
10
Nonoperating
5-100 HZ g2/Hz APSD:
100-200 Hz Slope dB/Octave:
200-350 HZ g2/Hz APSD:
350-500 Hz Slope dB/Octave:
500 HZ g2/Hz APSD:
GRMS overall:
Time/Axis minutes:
0.0175
–3
0.00875
–3
0.006132
2.22
10
Mechanical Shock, Nonoperating
1–4
30 g 1/2 sine, 11 ms duration 3 shocks
per surface (18 total)
TG 2000 Signal Generation Platform Service Manual
Specifications
Table 1–3: Environmental characteristics (cont.)
Characteristic
Performance requirement
Reference information
Transportation
Package qualified per Tektronix standard
062–2858–00 Rev. B “Environmental Test
Methods–Dynamics” and MBD Quality
Document ENVL–0060 “Transportation
Package Qualification Test Plan”.
Equipment Type
Test and Measuring
Equipment Class
Class 5
Table 1–4: System clock and frame reset
Characteristic
Performance requirement
Clock Frequency
Stability
Reference information
27 MHz
DDS Ch 1: 10 MHz to 100 MHz
DDS Ch 2: 10 MHz to 100 MHz
Step Size: 0.1 Hz
±1 ppm/year, operating at standard oven
temperature
Clock Jitter
≤30 ps RMS
Non-harmonic Clock Spurs
–45 dBc or better
Tune Range
± 10 ppm
Frame Reset
Two reset channels, 1.7 Hz to 1 kHz
TG 2000 Signal Generation Platform Service Manual
1–5
Specifications
Table 1–5: Certifications and compliances
Category
Standard
EC Declaration of Conformity
Compliance was demonstrated to the following specifications as listed in the Official
Journal of the European Communities:
EN 50081-1 Emissions:
EN 55022
EN 60555-2
EN 50082-1 Immunity:
IEC 801-2
IEC 801-3
IEC 801-4
IEC 801-5
Class B Radiated and Conducted Emissions
AC Power Line Harmonic Emissions
Electrostatic Discharge Immunity
RF Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Power Line Surge Immunity
Low Voltage Directive 73/23/EEC, Amended by 93/68/EEC
EN61010-1 Safety Requirements s for Electrical Equipment for Measurement,
Control, and Laboratory Use
Safety
U.S. Nationally Recognized Laboratory
Listing
ANSI/ISA S82.01 Safety Standard for Electrical and Electronics Test, Measuring,
Controlling, and Related Equipment, 1994
Canadian Certification
CAN/CSA C22.2 No. 1010.1 Safety Requirements for Electrical Equipment for
Measurement, Control, and Laboratory Use
European Union
Low Voltage Directive 73/23/EEC, Amended by 93/68/EEC
EN61010-1 Safety Requirements for Electrical Equipment for Measurement,
Control, and Laboratory Use
Additional Compliance
UL3111-1 Standard for Electrical Measuring and Test Equipment
IEC1010-1 Safety Requirements for Electrical for Measurement, Control, and
Laboratory Use
Safety Certification Compliance
1–6
Temperature, operating
41_ F to 104_ F (+5 to +40_ C)
Altitude (max operating)
6562 feet (2000 meters)
Equipment Type
Test and Measuring
Safety Class
Class I (as defined in IEC 1010–1, Annex H) – grounded product
Overvoltage Category
Installation Category II (as defined in IEC 1010–1, Annex J).
Pollution Degree
Pollution Degree 2 (as defined in IEC 1010–1). Rated for indoor use only.
TG 2000 Signal Generation Platform Service Manual
Operating Information
This section contains the following information:
Installation instructions
Operating information
All modules that you order are shipped configured and installed in the TG 2000
Platform mainframe. Refer to Options on page 7–1 for information about any
installed options. To install or remove a module, refer to the user or service
manual for that specific module.
Installation
Before you install the TG 2000 Platform mainframe, observe these environmental considerations:
Electrical Installation
Provide the appropriate operating environment. Refer to Specifications for
temperature, humidity, altitude, and other environmental requirements.
Leave enough space for instrument cooling by ensuring standard side
clearance for rackmount installation or 2 inches (5.1 cm) of side clearance
for countertop use.
Ensure rear clearance of approximately 2 inches (5.1 cm) so that cables are
not damaged by sharp bends.
To install the TG 2000 Platform mainframe, perform these steps:
WARNING. To avoid electrical shock, be sure that the power cord is disconnected
before checking the fuse or changing the setting of the Line Selector switch.
To avoid damaging the TG 2000 Platform mainframe, always use the correct
fuse for the local line voltage. Refer to Table 2–1 on page 2–2 or the fuse chart
located on the rear panel for the proper fuse rating for each line voltage setting.
1. Using the information in Figure 2–1, set the rear-panel Line Selector switch
to the correct position for your local AC power system.
2. Check that the correct line-voltage fuse for your local AC power system is
installed. Refer to Table 2–1 for the fuse ratings.
TG 2000 Signal Generation Platform Service Manual
2–1
Operating Information
Line
selector
Fuse
Power
switch
AC line
connecter
Figure 2–1: Location of the rear-panel power connector and configuration
Table 2–1: AC power fuse requirements
Line Voltage Setting
Fuse Rating
115 V
250 V, 6 AT
230 V
250 V, 3 AT
3. Check that the CPU configuration switch is in the “0” position. See
Figure 2–2.
4. Check that you are using the correct power cord for the local AC power
system. Refer to Options on page 7–1 for a list of power cords.
5. Connect the power cord from the rear-panel power connector to the AC
power system.
2–2
TG 2000 Signal Generation Platform Service Manual
Operating Information
Top view of
instrument
Figure 2–2: Location of the CPU configuration switch (switch set to 0)
Rackmount Installation
To rackmount the TG 2000 Platform mainframe, perform the following steps:
1. Connect the rackmount hardware to the rack, as shown in Figure 2–3.
2. Carefully begin inserting the rack pieces attached to the TG 2000 Platform
mainframe into the pieces attached to the rack. See Figure 2–4.
WARNING. To prevent the TG 2000 Platform mainframe from falling and causing
injury to yourself and damage to the instrument, be sure that the stop latches
snap into position in the slide-out track on both sides of the instrument. See
Figure 2–4.
3. Support the instrument until the stop latches click into place on both sides.
4. Continue to slide the TG 2000 Platform mainframe completely into the rack.
TG 2000 Signal Generation Platform Service Manual
2–3
Operating Information
Automatic latches
Rear mounting
bracket
Chassis section
Automatic latches
Flat bar nut
Stationary section
Intermediate
section
Stop latch
hole
Rear rack
10–32 Phs screws
Flat bar nut
Front rack
Flat bar nut
(Use if front rail
is not tapped)
10–32 Phs screw
Figure 2–3: Installing the rackmount hardware
2–4
TG 2000 Signal Generation Platform Service Manual
Operating Information
Side-out track
Stop latch
Figure 2–4: Installing the TG 2000 Platform mainframe into the rack
Rackmount Removal. Perform these steps to remove the TG 2000 Platform
mainframe from the rack:
1. Disconnect the power cord and any attached cables from the rear of the
instrument.
2. Slide the TG 2000 Platform mainframe out until it stops at the catches.
WARNING. To prevent the TG 2000 Platform mainframe from falling and causing
injury to yourself and damage to the instrument, be sure that the stop latches
snap into position in the slide-out track on both sides of the instrument.
3. Support the TG 2000 Platform mainframe while you depress the stop latch
buttons on each side of the instrument. See Figure 2–4.
4. Provide support while you slide the TG 2000 Platform mainframe completely out of the rack.
TG 2000 Signal Generation Platform Service Manual
2–5
Operating Information
Operating Information
This section contains instructions and procedures that will acquaint you with the
basics of operating the TG 2000 Platform mainframe so that you can perform
service on the instrument. Refer to the TG 2000 Signal Generation Platform
User Manual for detailed operating information.
This section includes instructions on the following topics:
Front-panel controls and indicators (page 2–6)
Using the touch screen (page 2–10)
Selecting test signals (page 2–12)
Using the disk drive (page 2–13)
Self Calibration (page 2–18)
Rear-panel connections (page 2–19)
Power-on procedure (page 2–21)
The primary method to control the TG 2000 Signal Generation Platform is to use
a combination of front-panel button and LCD display touch screen selections to
activate the functions within the instrument.
The secondary method to control the instrument is through the remote ports.
Refer to the user manual for detailed remote instructions.
Front-Panel Controls and
Indicators
The front-panel controls (see Figure 2–5) are divided into the following
functional sections:
System function
Keypad
Navigation
Miscellaneous function
After you select an instrument function, the selection may require a few seconds
to implement. A small hourglass icon is displayed in most cases while the
instrument implements your selection. Wait until the hourglass icon disappears
before you make another selection.
System Function. In most cases, when you push one of the System Function
buttons, a window opens on the LCD display providing touch-screen selections
related to the function of the button. For example, the Modules button displays a
window with selections that represent the installed generator modules.
2–6
TG 2000 Signal Generation Platform Service Manual
Operating Information
Figure 2–5: Instrument front panel
The following buttons and windows are useful when you have a question about
the operation of the instrument:
Help. Displays a window that explains details about the displayed window.
Status. Displays the following information about all installed modules:
module type, name, slot location, format, and output signal.
The status of an installed AGL1 module is listed at the bottom of the display.
System problems, such as a module failing the power-up self test, are also
displayed in the Status window.
Utilities. Provides access to the following housekeeping functions and
information: date and time, versions of installed modules, front-panel
timeout period, self calibration, clock clients, and frame-reset clients. Refer
to page 2–18 for a self calibration procedure.
The Locked LED (located below the References button) has three states to
indicate the status of the genlock function.
Illuminated. The instrument is locked to the external reference.
Blinking. The instrument is attempting to lock or is unable to lock to the
external reference. Check that the incoming signal matches the type chosen
in the Reference Select window. Also, ensure that the signal line is properly
terminated at the AGL1 loop-through connector or at the distant equipment
connection. The status bar gives the current status.
Off. The instrument reference selector Int/Ext is set to Internal and the AGL1
module is not active, or the AGL1 module is not installed.
TG 2000 Signal Generation Platform Service Manual
2–7
Operating Information
Keypad. Use the keypad to enter an exact quantity for a parameter. Use the scale
keys, such as k (kilo) and M (mega), to enter specific values. Table 2–2 shows
the purpose of each key.
Table 2–2: Keypad definitions
Key(s)
Function
0–9
Enters numeric values
.
Enters a decimal point
+/–
Toggles the numeric value between positive and negative
p/T
Enters the pico or Tera unit of measure1
n/G
Enters the nano or Giga unit of measure1
m/M
Enters the micro or Mega unit of measure1
m/k
Enters the milli or kilo unit of measure1
Escape
Exits out of data entry mode without changing the existing data
Back Sp
Erases one character
EE
Allows exponent entry. When entering a parameter value, enter a
number, press the EE key, and then enter the exponent value. For
example, press 4.2 EE 6 to enter the value 4.2x106.
Enter
Changes the parameter value to the new value
1
The instrument determines which of the two units is appropriate based on
the parameter being set.
Navigation Controls. The following navigation controls provide an alternative
method to touching onscreen display items to select them:
Arrow Buttons. Use these buttons to navigate through lists and objects on
the display and to move the cursor when entering text.
Knob. Use the knob to scroll through a list or to change a parameter setting.
Turn the knob to browse items in a window and to select characters in a text
entry window. When you have a numeric item selected, the knob will change
the value for the selected parameter. When you change a parameter, the
module output changes immediately.
Select. Use the Select button to confirm an entry or to make a browsed
selection active. Push the Select button repeatedly to sequence through items
within an icon when it contains several selections.
Touching a display item immediately activates the item. You can use the arrow
buttons and knob to move from item to item on the display without activating
them. This technique is known as browsing. To activate a browsed item, push the
Select button or touch the browsed display icon. See Figure 2–6.
2–8
TG 2000 Signal Generation Platform Service Manual
Operating Information
Browsed item
Selected item
Figure 2–6: Browsed and selected display icons
Miscellaneous Function Buttons. The four buttons at the right edge of the front
panel provide the following functions:
Front Panel Enable. This button acts like a toggle switch to enable (LED on)
or disable (LED off) the front-panel keys, the knob, and the touch screen.
NOTE. The instrument turns the display off and disables the front-panel controls
when the front panel is not used for the specified timeout period. Push the Front
Panel Enable button to enable the front panel after it has timed out. Push the
Utilities button to access the timeout delay settings.
Remote. Push the Remote button to access control of the remote interfaces
through the Remote window. The following areas of control are available:
Serial Setup. This selection provides control of the serial RS-232
interface.
Parallel Setup. This selection provides control of the parallel interface.
Remote Only. This selection locks out the front-panel controls when
remote-only operation is desired. Touch the Quit icon in the Remote
Only window to return to front-panel operation.
Remote Port. This selection selects an interface port. You must select an
interface port before using it for transferring data or commands. Touch
the Remote Port icon repeatedly to cycle through the selections.
TG 2000 Signal Generation Platform Service Manual
2–9
Operating Information
GPIB Setup. This selection lets you set the GPIB configuration. This
selection is only available when the GP1 module is installed.
Screen Contrast. When screen contrast is active (LED on), rotate the knob to
adjust the screen contrast for the best viewing in your environment.
On/Standby. Push the On/Standby button (LED on/LED off respectively), to
turn the instrument off after all critical processes have been completed. This
leaves the instrument in a known state. The On/Standby button is different
than the rear-panel power switch, which immediately shuts off power to the
instrument regardless of any functions that are in process.
When the On/Standby button is set to On, the battery system charges at the
highest rate. When the button is set to Standby and the rear-panel power
switch is on, the battery system charges at a low or trickle rate.
Using the Touch Screen
The LCD display serves as a touch screen that lets you touch display icons to
make functional selections. Touching a display icon either selects the item or
displays additional selections.
The following features appear in the touch-screen windows. See Figure 2–7.
Icons. Icons are display symbols that represent and show the status of test
signals or other selectable items. Touching some display icons repeatedly
cycles through the available selections.
NOTE. Icons of the same function can appear as selections in more than one
window. For convenience, icons appear where they are functionally appropriate.
2–10
Status Bar. The Status Bar shows the active signal set and test signal for the
selected module (BG1:2 in Figure 2–7). The status bar also gives the status
of other functions, such as signal transfers.
Window Title. The Window Title shows the window name, which indicates
the selected function.
Slot: #. The slot number identifies the physical location of the selected
module to remind you which module outputs are being controlled. In
Figure 2–7, note that the slot # matches the “2” in the active module name,
BG1:2.
List box. Touch the List Box to show additional selections that are available
within a display icon, such as a list of test signals. To display the list box
selections, rotate the knob or touch the list box. To select a list box item, use
the cursor keys or the knob to highlight a selection, and then push the Select
button. Touch an open list box to close it without making a selection.
TG 2000 Signal Generation Platform Service Manual
Operating Information
Status bar
Window title
Location of the selected
module within the mainframe
Signal set and name
of active signal
Selected item
Selectable items
List box
Figure 2–7: Main display features
Page or << Page >>. Touch the Page icon to access the previous or following
page of display selections.
Quit/Save. Touch the Quit or the Quit/Save icon to return to a previous
display window. If you have made changes, you will be asked if you want to
save them. If you have changed a test signal, you will be prompted to enter a
signal name. The signal name you enter will always be preceded by an
underscore character to indicate a user-created test signal.
Reset. Touch the Reset icon to return a parameter setting to the value it had
when you entered the window.
Hourglass. A small hourglass icon is displayed in most cases when the
instrument is taking time to implement your selection. Wait until the
hourglass icon disappears before you make another selection.
TG 2000 Signal Generation Platform Service Manual
2–11
Operating Information
Selecting Test Signals
The System Function buttons named Module, Signal Sets, and Test Signals
provide access to the output signals. These buttons allow you to select a module,
a signal set within the module, and a particular test signal. After selecting a test
signal, you can set common module parameters and signal parameters for
individual signals. Figure 2–8 shows this test signal hierarchy.
Modules
Signal Sets
Test Signals
Module
Parameters
Signal
Parameters
Figure 2–8: Module and test signal hierarchy
Each module has a Module Parameters selection for parameters that apply to all
appropriate test signals from that module. Each test signal also has unique
parameters controlled through the Signal Parameters icon.
Shared Module Memory. Generator modules of the same type share their onboard
memory spaces to provide larger signal-storage areas. Signals stored on one
module can be loaded and output by other modules of the same type.
When you remove a module, the signals stored on the module are no longer
available to the remaining modules. Before removing a module, copy all signals
for the module type to a floppy disk. After removing the module, you can reload
removed signals from the disk providing there is enough free memory space to
load the signals.
2–12
TG 2000 Signal Generation Platform Service Manual
Operating Information
Using the Disk Drive
The disk drive provides a way to load and save signal sets and sequences for a
module. You can also save all current settings, called presets, for the mainframe
and its modules to the disk. The disk drive uses 3.5 inch, 1.44 Mbyte, MS-DOSformatted disks. The disks must be formatted before using them in the drive.
Supported File Types. The disk drive reads and writes several types of files that
support different functions. The following file types are supported:
Signal Sets. These files contain directories of signal groups and, at the
lowest level, test signals. Signal set files have a .dnl suffix and may contain
test signals for more than one type of module. Use the SDP2000 Signal
Development Program software to create signal sets and assign them to a
module type. You can also save signal sets from a module to the disk.
Presets. These settings files are stored in a special binary format that is
unique to each type of module. The settings can be saved to disk and
restored later.
Sequences. These are TCL files stored as ASCII text, which is readable by
any text editor. Sequence files contain a series of SCPI and TCL commands
that are entered using a text editor. Sequence files have a .seq suffix.
To specify a sequence file to run at instrument power on, load a sequence file
named AUTOSTRT into the instrument. At power-on, the instrument checks
the disk drive first and then the internally-stored sequence files for one
named AUTOSTRT. The instrument will automatically execute the contents
of the first AUTOSTRT file it finds.
Saving Signals to Disk. Test signals that can be output from a module can be
saved onto a disk. You should save all signals in a module to a disk before
removing the module. Modules will lose their signal memory after 30 seconds
when you remove them from the mainframe.
To save signals to a disk, follow these steps:
1. Insert a preformatted disk into the drive. Ensure that the disk is not write
protected.
2. Push the Disk button to open the Disk window and then touch the Save
Signals to Disk icon.
3. Touch the Select Source icon to display a window like the one in Figure 2–9.
4. Select a module type (such as AVG1 at the left of the display) by highlighting it with the arrow buttons, and then pushing the Select button. Move right
to select the signals you want to save to a disk file.
TG 2000 Signal Generation Platform Service Manual
2–13
Operating Information
Signals are displayed in a hierarchical list with the top of the list shown at
the left under the Signals header. The value Total Tagged: is the combined
size of the selected signals.
If there are more signals than will fit on one disk, use multiple disks and
select a smaller group of signals to save on each disk.
Figure 2–9: Selecting the Save Signals to Disk source
5. Touch Quit/Save when you have selected the signals to save to disk.
6. In the Save Signals to Disk window, touch Select Destination.
7. You can use the New Dir icon to create a directory on the disk. Otherwise,
touch the New File icon and give the output file a name. In Figure 2–10, a
directory named local was created, and then a file named test1 was created.
8. When the source and destination of the test signal are entered, you can save
the signals to disk. Touch the Start Save icon to begin the save process.
Saving signals to disk takes a brief length of time that depends on the
number and size of the signals you are saving.
2–14
TG 2000 Signal Generation Platform Service Manual
Operating Information
Figure 2–10: Selecting a Save Signals to Disk destination
Replacing Signals from Disk. You select Replace Signals from the Disk window
to load new signals in place of the currently installed signals for a module type,
such as the AVG1.
CAUTION. To prevent data loss, use caution with the Replace Signals function.
All signal sets currently loaded in the selected module type are DELETED, and
the replacement signals are then loaded into the selected module type. You
should consider saving all the signals in a module type to disk before using the
Replace Signals function.
Follow these steps to replace all signals for a type of generator module, such as
all installed AVG1 modules, with signals from a disk:
1. Insert a disk containing the signal sets into the disk drive.
2. Push the Disk button to open the Disk window, and then touch the Replace
Signals icon.
3. Use the arrow buttons to highlight the signal file you want to load, and then
press the Select button. In Figure 2–11, the file TEST1.DNL is selected.
4. Touch the Quit icon after you have selected the signal file.
5. The signals contained in the signal file (TEST1.DNL in this example) are
displayed in a hierarchical structure. Use the arrow buttons to select the
signals that you want to load. The displayed value Available: indicates the
free module memory remaining after the selected signals are loaded.
6. Touch the Start Replace icon to load the selected signals into the memory of
the compatible modules.
TG 2000 Signal Generation Platform Service Manual
2–15
Operating Information
Figure 2–11: Replacing test signals from disk
Adding Signals from Disk. To add signals to a module from the disk drive, follow
these steps:
1. Insert the disk with the test signals into the disk drive, and then push the
Disk button to open the Disk window.
2. Touch the Add Signals icon, and then touch Select Source.
3. Select the signal set file from A: drive and then touch the Quit/Load icon.
4. Select the signals that you want to add from the signal set file. In Figure 2–12, the Linearity signals under PAL1 are selected. When you have
selected the signals you want to add, touch the Quit/Load icon, and then
touch Quit/Load again to return to the Add Signals window.
2–16
TG 2000 Signal Generation Platform Service Manual
Operating Information
Figure 2–12: Selecting the source signals to add from disk
5. Touch the Select Destination icon, and then select the type of destination
module. If you are loading a single test signal, select the destination at the
top of the hierarchy and it will be placed in an appropriate lower folder. You
can also pick a bottom level folder for the destination.
If a mismatch between the source and destination hierarchy occurs, the
following error appears: “This selection is too deep given the source.” Try a
destination at a higher level in the hierarchy and let the TG 2000 Platform
mainframe pick the appropriate level to add the signal.
6. When you have selected the destination for the test signal you are adding,
touch the Quit/Load icon to return to the Add Signals window.
7. In Figure 2–13, the source file SPECIAL is selected from the disk drive. The
destination module type is AVG1, and the point in the hierarchy is PAL 1.
Note that the value Total Tagged: is the size, in kilobytes, of the files to be
loaded. The value Free: is the size, in kilobytes, of the free memory space on
the AVG1 module. If the Tagged value exceeds the Free value, the module
will not have enough memory space to contain the new signals. Reduce the
number of signals being loaded (Select Source) or delete a few signals from
the module (Delete Signals) to free signal space.
8. Touch the Start Load icon to transfer the signals into the destination module.
TG 2000 Signal Generation Platform Service Manual
2–17
Operating Information
Figure 2–13: Add Signals window with source and destination selected
Deleting Signals. To delete signals from a module, follow these steps:
1. Push the Disk button to open the Disk window and then touch the Delete
Signals icon.
2. Select the test signals or signal sets you want to delete. The value Total
Tagged: indicates the memory used by the selected signals.
Note that the custom signal files you create contain only signal-difference
data referenced from an original signal. The custom signals have a .sig suffix
and cannot be deleted without deleting the original signal.
3. Touch the Delete icon to remove the selected signals from the module.
Self Calibration
This function performs an auto calibration of the selected modules. Self
calibration does not require any external test equipment, though all output
connections of the modules to be calibrated must be terminated into 75 W.
Perform self calibration on a module anytime it has been replaced to ensure
proper performance of the generator. Refer to the module user manual for
information about any special setup necessary before starting self calibration.
NOTE. All installed modules have their outputs disabled during the calibration of
any module.
Allow a 20 minute warm-up period before performing self calibration.
2–18
TG 2000 Signal Generation Platform Service Manual
Operating Information
To calibrate one or more modules, follow these steps:
1. Push the Utilities button and touch the Module Self Cal icon.
2. Touch the module icons that you want to calibrate. Any or all modules may
be selected for calibration.
3. Ensure that all signal outputs for the selected modules are properly terminated into 75 W. (You do not need to terminate the Trigger outputs of any
module and the BG1 module outputs.)
4. Touch the Start Cal icon to begin calibration of the selected modules. The
number of modules selected determines the time required for calibration.
5. Check that no errors are displayed during calibration. Refer to Maintenance
on page 6–37 for troubleshooting information.
Rear-Panel Connections
Figure 2–14 shows the rear-panel connections for the TG 2000 Platform
mainframe. Connections to modules in slots 2 through 10 are discussed in the
appropriate module user manuals.
You must select an interface port before using it. To select the interface port,
push the Remote button, and then touch the Remote Port icon repeatedly to cycle
through the available choices.
AC Power. For important information on the AC power connection, fuse, and
line selector, refer to Electrical Installation on page 2–1.
RS-232
interface
AC
Power
Parallel
interface
0
CPU
Module
10
9
8
7
6
5
4
3
2
1
Clock
Module
Figure 2–14: Rear-panel connectors
TG 2000 Signal Generation Platform Service Manual
2–19
Operating Information
RS-232 Interface (Serial). This is a standard RS-232 interface for remote control
of the TG 2000 Platform mainframe and all installed modules. The RS-232
connector (on the CPU module) is a 9-pin, subminiature, D-type connector with
male contacts. The pin descriptions are shown in Figure 2–15.
To use the interface, connect the 9-pin serial/RS-232 output of your PC to the
9-pin RS-232 connector on the rear panel of the mainframe, using a 9-pinto-9-pin straight-through cable. If necessary, a 25-pin connector can be used, in
conjunction with a 9-pin-to-25-pin adapter.
Refer to the TG 2000 Signal Generation Platform User Manual for programming information.
Pin
number
6
1
9
5
RS–232
1.
2.
3.
4.
5.
6.
7.
8.
9.
Data connection at TG2000
mainframe rear panel
Not used
RXD (Received Data)
TXD (Transmitted Data)
Not used
Ground
DSR (Data Set Ready)
RTS (Request To Send)
CTS (Clear To Send)
Not used
Figure 2–15: RS-232 connector pin descriptions
Parallel Interface. The parallel interface is a 25 pin D-type connector on the CPU
module. The main purpose of the Centronics-compatible port is for transferring
signal sets from the SDP2000 Signal Development Program software into the
generator modules.
NOTE. For proper operation of the parallel interface, ensure that all 25
connector pins are connected straight through your cable.
GPIB Interface. The optional GP1 Interface module provides a GPIB interface.
For information on this interface, refer to the GP1 Interface Module User
Manual.
2–20
TG 2000 Signal Generation Platform Service Manual
Operating Information
Power-on Procedure
The following procedure describes how to check that the TG 2000 Platform
mainframe powers on properly.
1. Before applying power to your TG 2000 Signal Generation Platform, check
the following items:
a. Check for proper installation. Refer to Installation on page 2–1.
b. Check that the power cord is connected to the AC line source.
2. Set the rear-panel Power switch to on.
3. Push the front-panel On/Standby button to apply power.
During power-on, the TG 2000 Platform mainframe performs a self test to
verify functionality. The self test requires a minute or less to complete,
depending on the number of modules installed. The front-panel display will
be on with no displayed errors after the self testing successfully completes.
If your TG 2000 Platform mainframe powers on, but an installed module
fails to appear in the Modules window, refer to Maintenance for troubleshooting instructions.
4. Once the power-on self tests are complete, the TG 2000 Platform mainframe
recalls the settings that were active when the instrument was powered off.
The power-on settings are stored in nonvolatile memory.
5. When you first power on the TG 2000 Platform mainframe after shipment or
long storage, leave the front-panel On/Standby button set to on (LED on) for
12 hours to fully charge the system batteries. The batteries maintain the test
signal data NVRAM when the mains power is disconnected.
NOTE. If backup power is lost, you must reload the test signal data into NVRAM
from the disks supplied with your user manual or through a remote port. After
reloading the test signal data, run a self calibration on all modules.
TG 2000 Signal Generation Platform Service Manual
2–21
Operating Information
2–22
TG 2000 Signal Generation Platform Service Manual
Theory of Operation
This discussion provides an overview of the main components of the TG 2000
Signal Generation Platform. This discussion covers general interactions with the
modules. For information about a specific module, refer to the user manual for
that module.
Block Level Description
Figure 3–1 shows a simplified block diagram of the TG 2000 Signal Generation
Platform
Generator
Module
Front
Panel
Signal
Memory
Disk
Drive
Mainframe
CPU
Generator
Module
Remote
Control
Signal
Memory
RS-232
CPU
Bus
Parallel
GPIB
(optional)
External
Reference
Signals
Out
Memory
Clock
Genlock
Signals
Out
Clock
Bus
Nine
Modules
Slots
Black
Burst
Module
Signals
Out
With AGL1 Option
Figure 3–1: Simplified block diagram
System Control
As shown in Figure 3–1, the mainframe CPU coordinates front panel and remote
interface commands and uses that input to set up the modules, the clock, and the
optional AGL1 Genlock module. The CPU sends data and control messages over
the CPU bus to set up the generator modules to perform a function, such as load
a test signal into module memory or change the output configuration.
TG 2000 Signal Generation Platform Service Manual
3–1
Theory of Operation
Power Supply
The 220 W power supply has a rear-panel switch to select between 115 V and
230 V operation.
The power supply delivers voltages to the various modules and mainframe
components and to the two cooling fans. The rear-panel switch is a hard power
switch, while the front-panel switch is a soft power switch.
Disk Drive
3–2
The disk drive provides an easy way to load signal sets, presets, sequences and
other data. It also provides a way to export the same types of data. The drive
supports 1.44 Mbyte, MS-DOS format disks. The complete signal sets for each
module type are shipped with the module on 3.5 inch disks.
Remote Control
Most front-panel control functions can be remotely controlled using the RS-232
or optional GPIB port. A computer or other controller sends SCPI compatible
commands to set up the mainframe or a specific module. Each module must be
individually set up, using its own set of commands. The mainframe and modules
use some of the same commands, but each also has unique commands. The SCPI
command set for each module is described in section 3 of the module user
manual.
Generator Modules
There are eleven module slots in the mainframe. The Clock and CPU modules
are required for system operation and permanently occupy two special slots (they
must be installed in these slots). The BG1 Black Burst Generator module is also
a standard component of the mainframe, but it can be moved or replaced with
another module if desired. Without the BG1 Generator module, optional AGL1
Genlock module or optional GP1 Interface module, there is room for nine
generator modules. Any combination of different generator modules and/or
multiples of the same generator module may be used.
Signal Memory
Most generator modules contain NVRAM for storing test signals. The test
signals are initially loaded from the supplied disks or through the parallel or
RS-232 port into NVRAM. The signal that is selected for output is loaded into
fast memory on the module. The loaded signal configures the module to
immediately output the selected signal. The flexible memory architecture allows
one generator module to output signals stored on another module of the same
type. Installing four of the same type of module, such as the AVG1 Generator
module, provides four times the signal storage space. All four modules have
equal access to this expanded memory space.
Battery Backup for
NVRAM
A central rechargeable battery maintains NVRAM data in the mainframe and
modules when AC power is not connected. The power supply quick charges the
battery while the instrument power is on. When the instrument is turned off
using the front-panel On/Standby switch, the battery is trickle charged. The
battery is not recharged while the rear-panel power switch is off.
TG 2000 Signal Generation Platform Service Manual
Theory of Operation
The power drain on the battery is low enough to allow module memory to
remain intact for many months. When you add more modules or modules that
use more power, the length of time that the memory remains intact is shortened.
In the event of memory failure from power loss, reload the signal memory
(NVRAM) from the supplied disks or through a remote port, and then run self
cal on all modules.
NOTE. When you first turn on the mainframe, leave it turned on for at least 12
hours to fully charge the backup battery. Do this also after you replace the
backup battery.
Clocks and Frame Reset
Signals
The 27 MHz master clock synchronizes the clocks and frame reset pulses that
control module timing, as shown in Figure 3–2. The Clock module provides
three high-speed clock signals, one at 27 MHz, and two at rates from 10 MHz to
100 MHz. In addition, there are two frame resets which allow different modules
to operate in separate television standards, such as PAL and NTSC.
The TG 2000 Signal Generation Platform can generate different standards, such
as PAL and NTSC, at the same time, using the 27 MHz or the two adjustable
clocks and the two frame reset pulses. The clocks and frame reset pulses ensure
that all modules driving the same format remain synchronized. The CPU
configures the clock to generate the clock frequencies and frame reset pulses
needed to support the different video formats.
TG 2000 Signal Generation Platform Service Manual
3–3
Theory of Operation
CPU Bus
Frame
Counter
Temperature Controlled
Master Oscillator
(27 MHz)
Frame Reset 1
Reset
Digital
Frequency
Synthesizer
Frame
Counter
Black Burst In
Black Burst In
Clock 1
Frame Reset 2
Reset
AGL1
Genlock
Preset
Digital
Frequency
Synthesizer
Sine Wave
(optional module)
Clock 2
27 MHz Clock
Figure 3–2: Block diagram of the clocks and frame reset signals
External Reference
Genlock
Module Timing Delay
An external reference may be used by the optional AGL1 module to lock on one
of several video standards. All modules using the same standard as the AGL1
Genlock module are locked to the external reference. Refer to the AGL1 Genlock
module user manual for a list of the supported formats.
Most generator modules can be separately timed with respect to the system. This
is accomplished by applying a precise, variable delay to the system clocks and
frame resets as they enter the module. For conventional television, the adjustment range is effectively infinite, providing adjustment over a complete color
frame.
An adjustable trigger output is available on some modules to synchronize
external test equipment to any location in the test pattern.
Timing References
3–4
The TG 2000 Signal Generation Platform supports internal or external references
and signal delay relative to this reference. Video reference signals synchronize
the start of test signals of the same type, such as NTSC or PAL. The AGL1
module is required to use external references.
TG 2000 Signal Generation Platform Service Manual
Theory of Operation
System delay and module timing delay are available to adjust for different signal
path delays in an operating environment. System delay uses the optional AGL1
module to lock the system to an external reference signal. Once the reference is
defined, you can add a common delay to all modules that generate the same
format as the external reference.
Module timing delay, which is available with some modules, allows the delay of
one module from other modules that generate a compatible format. Module
timing delay does not require an AGL1 module.
Figure 3–3 shows the effects of the system delay and the individual module
delay. Note that the BG1 module is at time zero for intermodule timing because
it does not support module delay. In Figure 3–3, the BG1 module and AVG1
output signals are delayed 5 ms by the AGL1 module. The AVG1 module is
delayed an additional 15 ms by the AVG1 module system delay timer.
External
reference black
burst signal
BG1 Module
AVG1 Module
5 s Genlock
delay
15 s
module
delay
20 s total
AVG1 delay
Figure 3–3: Comparison of module delay and system delay from a reference
TG 2000 Signal Generation Platform Service Manual
3–5
Theory of Operation
Timing Delay Block
Diagram
Figure 3–4 shows how the module delay is implemented for the generator
modules that support it. They have the ability to delay the clock and frame reset
pulse for half a frame. The delay is by a number of vertical lines plus a
horizontal delay up to the duration of one scan line. The delay is set in the
Module Timing window. (The variable system clocks also support module
delay.)
BG1
Module
AVG1
Module
AVG1
Module
DVG1
Module
Delay
Delay
Delay
27 MHz Clock
Clock
Frame Reset 1
Frame Reset 2
Figure 3–4: Block diagram of module timing delay
System Reference Delay
with the AGL1 Module
Figure 3–5 shows how the AGL1 Genlock module can delay its lock signal to
effectively delay the clock and frame pulses to all modules. Delaying the clock
and frame pulses results in a corresponding delay in the module output. All
generator modules using the same standard are affected equally by this delay.
VCO control
Frame signals
External
Video IN
AGL1
Genlock
Module
Delay
Clock
Clock
Figure 3–5: Block diagram of the AGL1 Reference timing delay
3–6
TG 2000 Signal Generation Platform Service Manual
Performance Verification
Perform the procedures in this section to verify the operation of the TG 2000
Platform mainframe. You do not need to remove the covers from the mainframe.
Verification Interval
To ensure correct instrument operation, perform these procedures once a year.
Before performing any procedures, complete all relevant maintenance procedures
outlined in the Maintenance section of this manual.
Test Equipment Required
Required equipment is shown in Table 4–1. Equipment suggestions are given in
the example column. You can substitute other equipment if it meets the
requirements in the Minimum specification column. If you do not have the
required equipment, you can return your instrument to a Tektronix service center
for performance verification.
Table 4–1: Test equipment required for verification
Equipment
Minimum specification
Purpose
Example
Frequency counter
Accuracy and resolution to 8 decimal places, or
used with an external reference (WWV, Loran C,
or GPS) that will improve the accuracy to 8
decimal places. Frequency 27 MHz.
To check the clock frequency.
(This is checked in more detail
in the BG1 Black Burst Generator Service Manual.)
Tektronix CDC250
Counter
75 W coaxial cable
BNC connectors; 1-meter length
Check clock frequency
012-0074-00
Autotransformer
Voltage range appropriate for the voltage range
to be tested
Check input voltage range
Variac – W10MT3W
3.5 inch disk
High density, DOS formatted
Check disk drive operation
IBM-compatible PC
Able to load and run the SDP2000 Signal
Development Program. See its user manual for
requirements.
Check the remote interface
(parallel and serial)
SDP2000 Signal Development Program software
and user manual
Standard accessory that is shipped with the
mainframe
Check the remote interface
(parallel and serial)
Four disks, shipped
with the SDP2000
manual
Parallel cable
25 pin D-type connector
Check the parallel interface
012-1214-XX
Serial cable
9-pin subminiature D-type connector
Check the serial interface
012-0911-XX
TG 2000 Signal Generation Platform Service Manual
4–1
Performance Verification Procedures
Preparation
1. Install all modules into the mainframe if they are not already installed.
Installation instructions appear on page 2–1.
2. Power on the mainframe by setting both the rear-panel POWER switch and
front-panel ON/STANDBY switch to on.
3. Allow the mainframe and modules to warm up for at least 20 minutes before
performing any tests.
Verification Procedures
Check Input Voltage
Range
You can use this procedure to check either the 115 V or 230 V voltage range.
Test Equipment Required: You will need an autotransformer for this test. A
waveform monitor is optional (for step 6.).
Procedure: Check Input Voltage Range
1. Set the TG 2000 Platform mainframe rear-panel POWER switch to off.
2. Make sure that the TG 2000 Platform mainframe is set for the voltage that
you want to check (115 or 230 V) and that the appropriate fuse is installed.
Use the 6 A fuse (159-0342-XX) for 115 V, and the 3 A fuse (159-0005-XX)
for 230 V.
3. Connect the mainframe power cord to the autotransformer.
4. Power on the autotransformer and set it for the nominal voltage you want to
check (either 115 or 230).
5. Power on the TG 2000 Platform mainframe, both the rear-panel POWER
switch and the front-panel ON/Standby switch.
6. Vary the autotransformer from 87 to 132 V or from 174 to 250 V and check
that the instrument operates across the voltage range. (For greater confidence, hook up the video outputs to a waveform monitor and check for a
stable display of the video signal on the waveform monitor display while
varying the voltage to the mainframe.) If the front-panel display disappears,
proceed to Troubleshooting in Section 6 of this manual.
7. Unplug the mainframe from the autotransformer. Make sure the mainframe
power setting and fuse are appropriate for your AC power source, and then
plug the mainframe into the AC power source.
4–2
TG 2000 Signal Generation Platform Service Manual
Performance Verification Procedures
Check Fan Operation
The TG 2000 Platform mainframe contains two fans, which should remain in
operation while the mainframe is operating.
Procedure: Check Fan Operation
Inspect the mainframe while it is operating to be sure that both fans are
operating. You should be able to hear the fans, and to feel vibration on the sides
of the mainframe cabinet. If either fan is not operating, proceed to Troubleshooting in Section 6 of this manual.
Check CPU Module
Use the following procedures to check the operation of the CPU module.
Test Equipment Required:
IBM compatible computer
SDP2000 software and user manual
Serial cable
Parallel cable
Blank disk
Procedure: Check Disk Drive
Create a directory named “test” on the disk as follows:
1. Insert the disk into the mainframe disk drive.
2. Push the Disk button to enter the Disk window.
3. Touch Save Signals to Disk on the display. See Figure 4–1.
Figure 4–1: Save Signals to Disk window
TG 2000 Signal Generation Platform Service Manual
4–3
Performance Verification Procedures
4. Touch Select Destination on the display.
5. Touch New Dir on the display.
6. Create a directory named “test” by touching the letters t e s t on the display.
See Figure 4–2. If you make a mistake, touch BS to back space.
Figure 4–2: New Directory window
7. Touch OK on the display.
8. Check that the new directory appears in the second column under Directories of the Save Signals to Disk window as shown in Figure 4–3. If the
directory does not appear, check that your disk is not write protected or try a
new formatted disk. Continued failure may indicate a defective disk drive.
Figure 4–3: New directory named Test
4–4
TG 2000 Signal Generation Platform Service Manual
Performance Verification Procedures
Procedure: Check Front-Panel Interface
This procedure checks the front-panel buttons and touch screen operation. It also
checks the time and date setting.
1. Check that the On/Standby LED is lighted.
2. Check each front-panel button with an LED (except for the On/Standby
button) to be sure that the LED lights when you push the button. Follow
these special instructions:
a. Listen for a ‘beep’ sound each time you push a front-panel button. This
indicates that the button is making contact.
b. After checking the Enable front-panel button, be sure to leave it in the
enabled position (LED on) so that you can continue to use the front-panel interface.
c. To check the Edit button LED, push the Modules or List button followed
by the Edit button.
d. Some of the front-panel buttons remain selected until you select another
system function button. For example, to exit the Remote or Modules
mode, you must push another front-panel button.
3. Push the Utilities button. Push each of the four directional arrow buttons on
the front panel and check that the displayed highlight moves accordingly.
4. Use the directional arrows to highlight Set Date/Time on the display, and
then push the Select button.
5. Check that the date and time are correct. If not, select each parameter and
adjust it, using the knob or front-panel keyboard.
If this clock does not keep time from power off to power on, refer to
Troubleshooting in the Maintenance section of this manual.
6. Touch Load on the display.
7. Touch Quit on the display.
8. Push the Presets button.
9. Touch Presets on the display.
10. Touch Create on the display.
11. Touch a, b, c, d, e, f, g, and h on the display. Listen for a ‘beep’ as you
touch each character. Touch BS to back space over the letters you typed.
Repeat with the rest of the alphabet.
12. Touch Cancel on the display. Touch Quit on the display.
TG 2000 Signal Generation Platform Service Manual
4–5
Performance Verification Procedures
Procedure: Check LCD Contrast
1. Push the Screen Contrast button.
2. Turn the knob to vary the screen contrast. Be sure it works smoothly over the
adjustment range.
3. Leave the contrast set as desired for best viewing.
4. Push the Screen Contrast button again. The LED will go off.
Procedure: Check Serial and Parallel Ports
Use the SDP2000 Signal Development Program software to check that the serial
and parallel ports are functional.
1. Install the SDP2000 software according to the instructions in the SDP2000
Signal Development Program User Manual.
2. Using the 25-pin cable, hook up the TG 2000 Platform mainframe parallel
port to a parallel port on your PC.
3. On the TG 2000 Platform mainframe, choose the parallel port as follows:
a. Push the Remote button.
b. Check the Remote Port selection at the bottom of the display. If it does
not already read Parallel, touch it once to toggle the setting to Parallel.
4. On the PC, perform the following tasks:
a. Open the Tek group (it may already be open from installation) and then
double click on the TGCOMM icon to open the communications portion
of the SDP2000 program.
b. To make the View menu commands available, open a .dnl file as
follows:
In the File Open dialog box, select the working directory that you
specified during SDP2000 installation.
Specify .dnl files in the List Files of Type box to display only
download files.
Open any .dnl file. One example is the file named
SDP2000/dvg1/dnls/525–1431.dnl.
c. From the Options menu, choose Parallel settings. Select the parallel port
you are using (Lpt 1, Lpt 2, or Lpt 3).
d. From the View menu, pull down the TG 2000 Signals command and
choose Parallel.
4–6
TG 2000 Signal Generation Platform Service Manual
Performance Verification Procedures
5. Check that the TGCOMM displays the list of TG 2000 signal names in the
right side of the window. The time it takes for the list to appear will vary
based on the speed of the PC. If the list does not appear, check the settings
and cable connections, cycle the TG 2000 Platform mainframe power and
restart the TGCOMM program. If the TGCOMM still does not display the
TG 2000 signal names, it could indicate a problem with the parallel port.
6. Disconnect the parallel cable and connect the serial cable between the
TG 2000 Platform mainframe serial port and a serial port on your PC. Be
sure that the CTS and RTS lines (pins 7 and 8 on the 9-pin serial connector)
are connected.
7. On the TG 2000 Platform mainframe, perform the following tasks:
a. Push the Remote button.
b. Touch Serial Setup on the display.
c. Note the Baud Rate.
d. Set the Flow Control to CTS/RTS and select Computer mode.
e. Touch the Remote Port selection at the bottom of display to toggle the
setting to Serial.
8. On the PC, perform the following tasks:
a. From the Options menu, choose Serial settings. Set the baud rate to
match the setting noted on the TG 2000 Platform mainframe and select
the serial port that you are using (COM1, COM2, COM3, or COM4).
b. From the View menu, pull down the TG 2000 Signals command and
choose Serial.
9. Check that the TGCOMM displays the list of TG 2000 signal names in the
right side of the window. If the list does not appear, check the settings and
cable connections, cycle TG 2000 Platform mainframe power and restart the
TGCOMM program. If the TGCOMM still does not display the TG 2000
signal names, it could indicate a problem with the serial port.
Check 27 MHz Clock
Frequency
Test Equipment Required:
Frequency counter
75 W coaxial cable
BG1 Generator module installed in the TG 2000 Platform mainframe. If you
do not have this module installed, you can use the adjustment procedure on
page 5–5 to check the clock frequency.
TG 2000 Signal Generation Platform Service Manual
4–7
Performance Verification Procedures
Procedure: Check 27 MHz Clock Frequency
1. Connect the Clock output and warm up instrument as follows:
a. Connect the Clock output from the BG1 Generator module to the
frequency counter as shown in Figure 4–4.
b. Connect the external reference to the frequency counter if needed (refer
to Table 4–1 on page 4–1).
c. Make sure that the mainframe and modules have warmed up for at least
20 minutes. If an AGL1 Analog Genlock module is installed, make sure
that the TG 2000 Signal Generation Platform is set to internal reference.
2. Set the TG 2000 Platform mainframe as follows:
a. Push the Module button and touch BG1 on the display.
b. Touch NTSC on the display.
c. Touch Black Burst on the display.
d. Touch Module Parameters on the display.
e. Touch Clock Out on the display.
f.
If the clock frequency is not set to 27.0 MHz, record the frequency
setting. You will restore this setting in step 5. Then press 2 7 /M and
Enter on the keypad. This sets the output frequency to 27.0 MHz.
g. If the selector Output at the bottom of the window indicates Disabled,
touch it once to enable the clock output on the BG1 module.
3. Set the frequency counter for AC coupling, 400 mV amplitude, 75 W, and
100 MHz range.
TG 2000 Platform mainframe
(rear panel)
BG1 Generator Frequency
module
counter
Clock output
Figure 4–4: Equipment setup for verifying clock operation
4–8
TG 2000 Signal Generation Platform Service Manual
Performance Verification Procedures
4. Check that the clock frequency, as measured on the frequency counter, is
27 MHz ±27 Hz (1 ppm). If it is not within this specification, go to the
Adjustments section and adjust the oscillator.
5. If you changed the clock frequency, restore the clock frequency noted in
step 2f.
6. Remove all cables from the mainframe.
This completes the performance verification for TG 2000 Platform mainframe.
Perform the Performance Verification procedure for each installed module as
described in your module service manuals.
TG 2000 Signal Generation Platform Service Manual
4–9
Performance Verification Procedures
4–10
TG 2000 Signal Generation Platform Service Manual
Adjustment Procedures
The procedures in this section should return the TG 2000 Signal Generation
Platform to operation within the specifications.
If, after you have performed the following adjustment procedures, the TG 2000
Platform mainframe does not meet or exceed specifications as determined by the
performance verification, repair is necessary. Contact your Tektronix Service
Center.
WARNING. Dangerous electric-shock hazards exist inside the system unit. To
prevent electrical shock, remove all jewelry before beginning any of the
adjustment procedures.
Equipment Required
Table 5–1: Equipment list for adjustments
Equipment
Specifications
Example or part number
Voltmeter with probes
Accurate to two decimal places
Tektronix DM2510 Digital Multimeter
Frequency counter
Accuracy and resolution to 8 decimal places, or used
with an external reference that will improve the
accuracy to 8 decimal places. Frequency 27 MHz.
BNC connectors; 1-meter length
Tektronix CDC250 Counter used with
external reference
75 W termination
Precision BNC. Enough to terminate all outputs of
installed modules (does not include the BG1
Generator module).
Tektronix Part Number 011-0102-01
75 W coaxial cable, SMB-to-BNC
Optional. Used to adjust the oscillator if a BG1
Generator module is not available.
Tektronix Part Number 174-3420-00
(5 inch cable)
75 W coaxial cable
TG 2000 Signal Generation Platform Service Manual
Tektronix Part Number 012-0074-00
5–1
Adjustment Procedures
Preparation
1. Install all modules into the mainframe if they are not already installed. Do
not install the mainframe in a rack. Remove the mainframe from the rack if it
is installed in one. Installation instructions appear on page 2–1.
2. Connect the TG 2000 Platform mainframe to the appropriate AC mains
power and switch on the rear-panel power switch.
3. Press the On/Standby button on the front panel. At power on, the instrument
runs self tests to check all functions of all mainframe components. If the
display is working and no errors appear on the display, the mainframe passed
its self tests.
The installed modules also run self tests at power on. To determine if they
passed their tests, press the Status key and check that no module has a
“Failed power up” status.
4. Wait 20 minutes for the mainframe and modules to warm up.
Self Calibration
This function performs an auto calibration of the selected modules. Do this
before making any adjustments. Self calibration does not require any external
test equipment.
NOTE. Allow a 20 minute warm-up period before performing self calibration.
Run the self calibration as follows:
1. Push the Utilities button and touch the Module Self Cal icon.
2. Ensure that all signal outputs for the modules that you want to calibrate are
terminated into 75 W. (You do not need to terminate the Trigger outputs of
any module and the BG1 module outputs.)
3. If desired, touch all module icons to perform self calibration on the
mainframe and all of the installed modules at once. To perform self
calibration on the mainframe only, touch the Clock module icon.
4. Touch the Start Cal icon to begin calibration of the mainframe and any
selected modules. Self calibration takes two to five minutes.
5. Check that no errors are displayed during calibration. If errors are displayed,
refer to the Maintenance section for troubleshooting information.
5–2
TG 2000 Signal Generation Platform Service Manual
Adjustment Procedures
Adjustment Procedure
NOTE. Perform the preceding Self Calibration procedure before making any
adjustments.
There are two areas of adjustment for the mainframe: the +5V supply and the
oscillator. Adjusting the +5V Supply is usually only necessary after installing a
new Power Supply board.
Adjust +5 V Supply
In this procedure, you will check the various supplies, and then adjust the +5V
Supply if necessary.
Test Equipment Required: You will need a voltmeter and probes for this adjustment.
Procedure: Adjust the +5V Supply
WARNING. Dangerous electric shock hazards exist inside the mainframe. Only
qualified service personnel should perform these procedures.
1. Check the + 5 V, –5 V, +15 V, –15 V, and –2 V supplies as follows:
a. At least the Clock and CPU boards must be installed in the mainframe,
and it is best to install all modules that will be used. As for all checks, be
sure you have allowed 20 minutes warm-up time.
2. Remove the top cover and set it aside.
3. There are four LED indicators on the Power Supply board, visible from the
top of the mainframe. Check them as follows:
a. Check that the red LED indicators (located on the top of the Power
Supply board) are off. The indicators are:
DS2 – overtemperature condition
DS3 – overvolts condition on the +5 V supply
DS4 – overcurrent condition
b. Check that the green LED indicator (DS1 on the Power Supply board) is
on.
4. Connect the voltmeter leads between ground and the +5V test point, near the
top edge of the clock board. See Figure 5–1 for the test point location.
5. Check that the output is 5 volts, + 50 mV.
TG 2000 Signal Generation Platform Service Manual
5–3
Adjustment Procedures
a. If it is within this tolerance, no adjustment is needed. Go to step 7.
b. If it is not within this tolerance, go to step 6 and adjust the power supply.
6. Adjust R39 for +5.00 volts on the voltmeter. The adjustment point is along
the top edge of the Power Supply board, as seen from the top of the
mainframe.
7. Connect the voltmeter leads between ground and each of the following
voltage points on the clock board, and check to the indicated tolerances:
–5 V test point for 5.1 V ±5% (–4.9 V to –5.4 V)
+15 V ± 2% (+14.7 V to +15.3 V)
–15 V ± 2% (–15.3 V to –14.7 V)
–2 V test point for – 2.2V ± 9% (–2.4 V to –2.0 V)
If any of the voltages are off, it may indicate a problem with the power
supply board. Proceed to Troubleshooting in the Maintenance section.
–2V
Oscillator
–5V –15V
+5V
+15V
GND
Figure 5–1: Checking the power supply voltages on the clock board
5–4
TG 2000 Signal Generation Platform Service Manual
Adjustment Procedures
Adjust Oscillator
You only need to adjust the oscillator if you used the Performance Verification
procedure to check the 27 MHz clock, and it did not meet specifications. To
adjust the oscillator, you will need the following equipment:
Frequency counter
75 W coaxial cable, BNC
75 W coaxial cable, SMB-to-BNC, needed only if BG1 Generator module is
not available
Procedure: Adjust the Oscillator
WARNING. Disconnect the power cord from the rear panel of the mainframe or
turn off the rear-panel power rocker switch before removing the cover of the
mainframe. Dangerous voltages can be present in the mainframe even when the
front-panel power switch is off.
1. Disconnect the power cord from the rear panel of the mainframe or turn off
the rear-panel power rocker switch to the mainframe. Remove the top cover
from the mainframe and set it aside.
2. Connect Clock output and warm up instrument as follows:
If you have a BG1 Generator module installed, perform parts a through g of
this step, then skip to step 3.
If you do not have a BG1 Generator module, perform parts j through n of
this step, then proceed to step 3.
WITH BG1 Generator module
a. Connect the Clock output from the BG1 Generator module to the
frequency counter as shown in Figure 5–2.
TG 2000 Platform mainframe
(rear panel)
BG1 Generator Frequency
module
counter
Clock output
Figure 5–2: Adjusting the oscillator using the BG1 Generator module
TG 2000 Signal Generation Platform Service Manual
5–5
Adjustment Procedures
b. Connect the AC power to the rear panel of the mainframe, power on the
mainframe, and wait 20 minutes for the mainframe and modules to
warm up.
c. Push the Module button and touch BG1 on the display.
d. Touch NTSC on the display.
e. Touch Black Burst on the display.
f.
Touch Module Parameters on the display.
g. Touch Clock Out on the display.
h. If the frequency is not set to 27.0 MHz, record the frequency setting.
(You will restore this setting in step 7.) Then press 2 7 /M and Enter
on the keypad. This sets the output frequency to 27.0 MHz.
i.
If the selector Output at the bottom of the window indicates Disabled,
touch it once to enable the clock output on the BG1 module.
WITHOUT BG1 Generator module
j.
Make sure that you do not have power applied to the TG 2000 Platform
mainframe.
k. Loosen the rear-panel screws at the bottom of slots 1 and 2. Remove the
Clock module from slot 1.
CAUTION. Do not allow the connectors on the coaxial cable to touch any
components on the inside of the instrument.
l.
Connect the SMB-BNC cable to J109 on the Clock module. See
Figure 5–3 for the location of J109. Connect the BNC end of the cable to
a 75 W coaxial cable, and then connect the other end of the 75 W cable to
the frequency counter input.
m. Reinstall the Clock module into the mainframe and install the screws
that were removed in step k.
n. Be sure that the BNC connectors do not touch any components. Connect
the AC power to the rear panel of the mainframe, power on the
mainframe, and wait 20 minutes for the mainframe and modules to
warm up.
3. If an AGL1 Analog Genlock module is installed, make sure that the
TG 2000 Signal Generation Platform is set to internal reference.
5–6
TG 2000 Signal Generation Platform Service Manual
Adjustment Procedures
4. Make sure that the DS100 LED is off. The location of this red LED is shown
in Figure 5–3.
(The LED lights when the TG 2000 Platform mainframe is powered on, and
remains lighted until the oscillator is sufficiently warmed up to perform this
adjustment.)
GL SLOT 2 IN
J109
27 MHz clock
DS100
Oscillator
GL SLOT 3 IN
Figure 5–3: Locating parts on the clock board
5. Set the frequency counter for AC coupling, 400 mV amplitude, 75 W, and
100 MHz range. Connect the external reference, if needed (refer to
page 5–1).
6. Adjust the oscillator through the hole in the top of its case. Adjust for
27.000000 Mhz±1Hz, as read on the frequency counter. The specified
accuracy is 1 ppm per year (±27 Hz). Failure to meet specification may
indicate a problem with the clock circuit. Proceed to Troubleshooting in the
Maintenance section.
7. If you used a BG1 Generator module, and you changed the clock frequency,
restore the clock frequency noted in step 2h.
8. Disconnect all cables, replace the mainframe cover, and install and tighten
the screws.
This completes the adjustment procedure.
TG 2000 Signal Generation Platform Service Manual
5–7
Adjustment Procedures
5–8
TG 2000 Signal Generation Platform Service Manual
Maintenance
This section contains instructions and procedures for maintaining the TG 2000
Platform mainframe. Refer to the service manuals for the individual generator
modules for specific instructions on servicing those modules.
The following information can be found in this section:
Preparation
page 6–1
Inspection and cleaning
page 6–3
After repair adjustments
page 6–4
Repackaging instructions
page 6–4
Removal and replacement procedures
page 6–9
Troubleshooting procedures
page 6–37
If the instrument does not function properly, troubleshooting and corrective
measures should be taken immediately to prevent additional problems.
NOTE. Contact your local Tektronix representative for information on where to
return your instrument if it requires repair during the warranty period.
Preparation
Please read and follow these preparation instructions before attempting to
perform any maintenance or service to the instrument.
Servicing Prerequisites
Make sure of the following before beginning any instrument service:
The maintenance or service of this instrument must be performed by
qualified service personnel only.
Read the Service Safety Summary located at the beginning of this manual
before attempting to perform any maintenance or service to the instrument.
Read the Operating Information section of this manual before attempting to
perform any maintenance or service to the instrument.
TG 2000 Signal Generation Platform Service Manual
6–1
Maintenance
Electrostatic Damage
Prevention
This instrument contains electrical components that are susceptible to damage
from electrostatic discharge. Static voltages of 1 kV to 30 kV are common in
unprotected environments.
CAUTION. Static discharge can damage any semiconductor component in this
instrument.
Observe the following precautions to avoid static damage:
Minimize handling of static-sensitive components.
Transport and store static-sensitive components or assemblies in their
original containers, on a metal rail, or on conductive foam. Label any
package that contains static-sensitive assemblies or components.
Discharge the static voltage from your body by wearing a wrist strap while
handling these components. Servicing static-sensitive assemblies or
components should only be performed at a static-free workstation by
qualified personnel.
Nothing capable of generating or holding a static charge should be allowed
on the workstation surface.
Keep the component leads shorted together whenever possible.
Pick up components by the body, never by the leads.
Do not slide the components over any surface.
Avoid handling components in areas that have a floor or work surface
covering capable of generating a static charge.
Use a soldering iron that is connected to earth ground.
Use only special antistatic, suction-type or wick-type desoldering tools.
NOTE. A 2% RMA flux content solder is recommended for making repairs in this
instrument. Cleaning of rosin residue is not recommended. Most cleaning
solvents tend to reactivate the rosin and spread it under components where it
may cause corrosion under humid conditions. The rosin residue, if left alone,
does not exhibit these corrosive properties.
6–2
TG 2000 Signal Generation Platform Service Manual
Maintenance
Inspection and Cleaning
Preventive maintenance consists of cleaning, visual inspection, performance
checking, and, if needed, readjustment. The preventive maintenance schedule
established for the instrument should be based on the environment in which it is
operated and the amount of use. Under average conditions, scheduled preventive
maintenance should be performed every 2000 hours of operation.
General Care
Protect this instrument from adverse weather conditions. The instrument is not
waterproof.
Do not expose the LCD display to direct sunlight for long periods of time.
CAUTION. To avoid damage to this instrument, do not expose it to sprays,
liquids, or solvents.
To avoid damage to a module circuit board, do not flex the circuit board if you
remove the board from its mounting shield. The circuit board can be damaged by
flexing. The shield provides necessary structural support to the circuit board.
Cleaning
Clean the instrument often enough to prevent dust or dirt from accumulating.
Dirt acts as a thermal insulating blanket that prevents effective heat dissipation,
and can provide high-resistance electrical leakage paths between conductors or
components in a humid environment.
CAUTION. To avoid damage to the surface of this instrument, do not use abrasive
or chemical cleaning agents.
Remove dust from the exterior of the instrument with a lint-free cloth. Use care
to avoid scratching the touch screen. Use a small, soft-bristled brush to remove
dust from around the selector buttons and connectors. For further cleaning, use a
soft cloth or paper towel dampened with water or a 75% isopropyl alcohol
solution. If you must clean the interior of the instrument, allow the interior to
thoroughly dry before reassembling and applying power to the instrument.
Visual Inspection
After cleaning, carefully check the instrument for defective connections,
damaged parts, and improperly seated transistors or integrated circuits. If
heat-damaged parts are discovered, determine the cause of overheating before
replacing the damaged part.
Periodic checks of the transistors and integrated circuits are not recommended.
The best measure of performance is the actual operation of the component in the
circuit.
TG 2000 Signal Generation Platform Service Manual
6–3
Maintenance
Performance Verification
and Readjustments
Check instrument performance after each 2000 hours of operation or every
12 months. This will help to ensure maximum performance and assist in locating
defects that may not be apparent during regular operation. Performance
verification and adjustment procedures are included in this manual.
After Repair Adjustments
It is recommended that you perform the adjustment procedures for the Power
Supply module whenever you have replaced that module. Refer to the Adjustment Procedures section of this manual for instructions. The other mainframe
modules do not have adjustments.
Repackaging Instructions
Use the following instructions to prepare your instrument for shipment to a
Tektronix, Inc., Service Center:
1. Attach a tag to the instrument showing: the owner, complete address and
phone number of someone at your firm who can be contacted, the instrument
serial number, and a description of the required service.
2. Package the instrument in the original packaging materials. Figures 6–1,
6–2, and 6–3 illustrate how to repackage the modules and instrument in their
original packaging materials. If the original packaging materials are not
available, follow these directions:
a. Obtain a carton of corrugated cardboard having inside dimensions six or
more inches greater than the dimensions of the instrument. Use a
shipping carton that has a test strength of at least 250 pounds (113.5 kg).
b. Place the instrument in its carrying pouch or surround the instrument
with a protective bag.
c. Pack dunnage or urethane foam between the instrument and the carton. If
using Styrofoam kernels, overfill the box and compress the kernels by
closing the lid. There should be three inches of tightly packed cushioning on all sides of the instrument.
3. Seal the carton with shipping tape, industrial stapler, or both.
6–4
TG 2000 Signal Generation Platform Service Manual
Maintenance
Module
004-4712-00
Figure 6–1: Placing the module in the protective wrapping
TG 2000 Signal Generation Platform Service Manual
6–5
Maintenance
004-4713-00
2 Each
004-4712-00
004-0828-00
Figure 6–2: Placing the module in the shipping carton
6–6
TG 2000 Signal Generation Platform Service Manual
Maintenance
006-1663-00
Plastic bag
004-4706-00
Side protector 2 each
004-4708-00
Face protector
004-4709-00
Rear protector
020-2187-00
Accessory kit
351-0636-00
004-4705-00
Shipping box
Manual
Power cord
004-4707-00
Accessory tray
Figure 6–3: Placing the TG 2000 Platform mainframe in the shipping carton
TG 2000 Signal Generation Platform Service Manual
6–7
Maintenance
6–8
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
This section contains the instructions on how you can remove and replace the
customer replaceable modules and parts of the TG 2000 Signal Generation
Platform.
Tools Required
Use the tools in Table 6–1 to disassemble the instrument to its individual
modules. Some of these tools are required only for removal of specific instrument components.
Table 6–1: Tools required for module removal
Name
Description
Torx screwdriver handle
Accepts Torx-driver bits
T-10 and T-20 Torx tips
Torx-driver bit for T-10 and T-20 screw heads
#1 point Philips tip
Torx-driver bit for small Philips screw heads
1/2 inch hexagonal driver
Deep socket
9/16 inch hexagonal driver
Deep socket
9/16 inch wrench
1/4 inch hexagonal driver
1/16 inch hexagonal wrench
Torque wrench
16 inch-pounds
Flat blade screwdriver
Tweezers or needle-nose pliers
Cleaners
See Cleaning on page 6–3
Soldering iron
40 W
Solder
2% RMA flux content solder
TG 2000 Signal Generation Platform Service Manual
6–9
Removal and Replacement
Procedures
Table 6–2 lists the removal and replacement procedures in this section and their
starting page numbers.
Table 6–2: Removal and replacement procedure list
6–10
Replaceable part
Page number
Top cover
6–11
Front frame
6–12
Front Panel board and LCD Display module
6–13
Knob encoder
6–15
Airflow regulator
6–16
Floppy drive
6–17
Floppy drive assembly shield
6–20
Power Supply module
6–21
Power Supply board
6–24
Line Filter board
6–25
Fuse holder
6–26
CPU module
6–27
CPU Memory board
6–28
Date/time clock
6–29
Clock module
6–31
Clock board oscillator
6–31
Power supply fan
6–32
Clock module fan
6–33
Backplane board and shield
6–34
Backup battery
6–36
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
Top Cover
Remove the top cover by following the procedure below.
1. Turn off the TG 2000 Platform mainframe by pressing the On/Standby
button and setting the rear-panel power switch to off.
2. Remove the power cord.
WARNING. To avoid a shock hazard, always remove the power cord before you
remove the top cover. Failure to remove the power cord can result in serious
injury or death.
3. Refer to Figure 6–4 and remove or loosen all screws to remove the top cover.
To replace the top cover, install and tighten all of the screws in the previous
procedure.
Top cover
Remove screws (23)
Top cover
Loosen
screws
(12)
Figure 6–4: Top cover removal
TG 2000 Signal Generation Platform Service Manual
6–11
Removal and Replacement
Front-Frame Assembly
The front-frame assembly contains replaceable subparts. Procedures for
removing the subparts are included below.
Front Frame. To remove the front-frame assembly, perform the following
procedure:
1. Remove the top cover. Refer to Top Cover on page 6–11.
2. Disconnect the front-panel ribbon cable from the CPU module and slide the
cable out through the slot in the card guide.
3. Remove the four screws from the bottom of the chassis. See Figure 6–5.
4. Remove the four screws from the back of the bow handles.
Figure 6–5: Removing the front-frame assembly
6–12
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
To replace the front-frame assembly, perform the following procedure:
1. Place the front-panel ribbon cable through the slot in the card guide.
2. Place the front-frame assembly onto the end of the chassis and install the
four T-10 screws through the bottom of the chassis.
3. Install the four T-20 screws through the back of the bow handles and tighten
the four screws to 16 inch-pounds (1.81 Newton-meters) using the torque
wrench.
4. Connect the front-panel ribbon cable to the connector on the CPU board. See
Figure 6–5 for the correct cable orientation.
5. Replace the top cover. Refer to Top Cover on page 6–11.
Front Panel Board and LCD Display Module. To remove the Front Panel board and
LCD Display module, perform the following procedure:
1. Remove the front-frame assembly. Refer to Front Frame on page 6–12.
2. Remove the front-panel knob using the 1/16 inch hexagonal wrench.
3. Place the front-frame assembly face down on a soft surface with both ends of
the front frame supported. See Figure 6–6.
Pin 1
Attaching
screws (15)
White rubber nubs (6)
Pin 1
Front-panel knob
Figure 6–6: Removing the front-panel board and display module
TG 2000 Signal Generation Platform Service Manual
6–13
Removal and Replacement
4. Disconnect the 14-pin cable from the LCD Display module.
5. Remove the three screws from the LCD Display module and the twelve
screws from the Front Panel board.
NOTE. The front-panel keypad buttons are seated loosely in the front frame.
Lifting the Front Panel board may cause these buttons to come out of their
seated positions. Lift the Front Panel board out of the front frame while pushing
the six rubber nubs through the circuit board to minimize the disturbance of
these buttons.
6. Lift the Front Panel board and LCD Display module from the front frame.
7. Disconnect the remaining three cables connecting the Front Panel board and
the LCD Display module. See Figure 6–7.
Pin 1
Figure 6–7: Disconnecting the LCD Display module and Front Panel board
To replace the Front Panel board and LCD Display module, perform the
following procedure:
1. Install any unseated keypad buttons into the front frame, and then install the
isomeric keypad into the keypad buttons.
2. Connect the two blue cables and the two-pin cable connecting the Front
Panel board and the LCD Display module.
3. Install the Front Panel board and LCD Display module into the front frame.
Make sure that the six rubber nubs from the keypad go through the holes in
the Front Panel board. Once the Front Panel is seated in position, pull the
rubber nubs through the circuit board.
6–14
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
4. Install the three screws into the LCD Display module and the twelve screws
into the Front Panel board.
5. Press the front-panel buttons to check that they operate freely and are not
sticking against the front frame. If the buttons are sticking, loosen the twelve
Front Panel board screws and adjust the circuit board as necessary. Tighten
the twelve screws when you have positioned the circuit board.
6. Connect the 14-pin cable from the Front Panel board to the LCD Display
module.
7. Install the front-panel knob using the 1/16 inch hexagonal wrench.
8. Replace the front-frame assembly. Refer to Front Frame on page 6–12.
Knob Encoder. To remove the front-panel knob encoder, perform the following
procedure:
1. Remove the Front Panel board. Refer to Front Panel Board and LCD
Display Module on page 6–13.
2. Disconnect the knob-encoder cable from the Front Panel board.
3. Remove the knob encoder retaining nut using the 1/2-inch hexagonal driver.
4. Slide the knob encoder through the back of the Front Panel board.
To replace the front-panel knob encoder, perform the following procedure:
1. Align and install the knob-encoder spacer on the knob encoder. See
Figure 6–8.
Figure 6–8: Replacing the knob encoder
TG 2000 Signal Generation Platform Service Manual
6–15
Removal and Replacement
2. Slide the shaft of the knob encoder through the back of the Front Panel
board.
3. Align the knob encoder and install the retaining nut.
4. Connect the knob-encoder cable to the Front Panel board.
Airflow Regulator. To remove the airflow regulator, perform the following
procedure:
1. Remove the front-frame assembly. Refer to Front Frame on page 6–12.
2. Remove the airflow regulator from the chassis.
To replace the airflow regulator, perform the following procedure:
1. Install the airflow regulator into the slots in the chassis. See Figure 6–9.
2. Replace the front-frame assembly. Refer to Front Frame on page 6–12.
Slot (3)
Figure 6–9: Replacing the airflow regulator
6–16
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
Floppy Drive Assembly
The floppy drive assembly contains replaceable subparts. Procedures for
removing the subparts are included below.
NOTE. The following procedure is for platforms with serial numbers B011100
and above. For platforms with serial number B011099 or below, contact your
Tektronix representative to purchase the Floppy Drive Replacement Kit for the
TG 2000 Signal Generation Platform.
Floppy Drive. To remove the floppy drive assembly, follow these steps:
1. Remove the front-frame assembly. Refer to Front Frame on page 6–12.
2. Remove the two attaching screws from the side of the chassis. See Figure 6–10.
3. Slide the floppy drive assembly out through the front of the chassis.
4. Remove the three screws from the floppy drive electrical shield (two on the
top and one on the bottom). See Figure 6–11. Save the screws.
5. Slide the floppy drive out of the electrical shield.
6. Disconnect the cable from the floppy drive, leaving the other end of the
cable connected to the CPU circuit board. See Figure 6–11. Keep the
protective sleeve on the cable.
Cable sleeve
Floppy drive
Figure 6–10: Removing the floppy drive
TG 2000 Signal Generation Platform Service Manual
6–17
Removal and Replacement
To replace the floppy drive, perform the following procedure:
1. Connect the cable from the CPU module to the new floppy drive.
2. Wrap the cable around the floppy drive and slide the new floppy drive and
cable into the new electrical shield. Make sure the cable sleeve is in position
as shown in Figure 6–11. Dress the excess cable toward the front of the
floppy drive, and not next to the CPU circuit board.
3. Install the three attaching screws through the electrical shield and into the
floppy drive, tightening the top two screws first and the bottom screw last.
4. Slide the floppy drive assembly into the chassis.
5. Install the two attaching screws into the side of the chassis.
6. Replace the front-frame assembly. Refer to Front Frame on page 6–12.
6–18
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
CPU module
Chassis
Screws (3)
Electrical shield
Floppy drive
Cable
Lift tab to release cable
Insert plated side
Cable sleeve
Figure 6–11: Installing the floppy drive into the chassis
TG 2000 Signal Generation Platform Service Manual
6–19
Removal and Replacement
Floppy-Drive Assembly Shield. The floppy drive assembly shield (Figure 10–3-2)
is an outer shield that encases the floppy disk drive and the electrical shield. To
remove the floppy drive assembly shield, perform the following procedure:
1. Remove the floppy drive assembly (floppy drive and electrical shield). Refer
to Floppy Drive on page 6–17.
2. Remove the Power Supply module. Refer to Power Supply Module on
page 6–21.
3. Remove the rackmount hardware from the floppy drive side of the chassis.
4. Remove the six attaching screws from the chassis. See Figure 6–12.
Floppy drive
assembly shield
Nuts (3)
Rackmount
track
Screws (6)
Figure 6–12: Removing the floppy drive assembly shield
5. Slide the floppy drive assembly shield out through the front of the chassis.
6–20
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
To replace the floppy drive assembly shield, perform the following procedure:
1. Slide the floppy drive assembly shield in through the front of the chassis.
2. Install the six attaching screws into the chassis.
3. Install the rackmount hardware onto the side of the chassis.
4. Install the Power Supply module. Refer to Power Supply Module on
page 6–21.
5. Install the floppy drive. Refer to Floppy Drive on page 6–17.
Power Supply Module
Assembly
The Power Supply module assembly contains replaceable subparts. Procedures
for removing the subparts are included below.
NOTE. Before replacing the Power Supply module, check the serial number of the
instrument chassis (located on the right side of the chassis). Instruments with
serial number B010391 and below require a wire-strap kit (Tektronix part
number 040–1522–XX) installed on the Power Supply module. See Figure 6–13.
Install the wire-strap kit at this time if it is required for your instrument and has
not already been installed.
Power Supply
module
Grounding strap
Figure 6–13: Location of the Power Supply module grounding strap (SN B010391
and below only)
Power Supply Module. To remove the Power Supply module, perform the
following procedure:
1. Remove the top cover. Refer to Top Cover on page 6–11.
TG 2000 Signal Generation Platform Service Manual
6–21
Removal and Replacement
2. Disconnect the fan cable from the Power Supply module, the ribbon cable
from the CPU module, and the two cables from the Backplane board. See
Figure 6–14.
CPU module
cable
Fan cable
Backplane board
cables
Figure 6–14: Removing the Power Supply module
6–22
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
3. Remove the six attaching screws from the bottom of the chassis and loosen
the lower attaching screw on the rear panel of the Power Supply module. See
Figure 6–15.
4. Lift the Power Supply module from the TG 2000 Platform mainframe.
Loosen lower
attaching screw
Remove
attaching screws
(6)
Attaching screw
(B010392 and above only)
Figure 6–15: Removing the Power Supply module attaching screws
To replace the Power Supply module, perform the following procedure:
1. Make sure that the two cables connecting the Backplane board and the Power
Supply module are firmly seated on the Backplane board connectors.
2. Slide the Power Supply module into the TG 2000 Platform mainframe.
3. Install the six attaching screws into the Power Supply module and tighten the
lower screw on the rear panel of the Power Supply module.
4. Connect the fan cable to the Power Supply module, the ribbon cable from
the CPU module, and the two cables from the Backplane board. See
Figure 6–14.
5. Replace the top cover. Refer to Top Cover on page 6–11.
TG 2000 Signal Generation Platform Service Manual
6–23
Removal and Replacement
Power Supply Board. To remove the Power Supply board, follow these steps:
NOTE. If you return the Power Supply board to Tektronix for module exchange,
do not return any of the four attaching cables. The cables will not be included in
the exchange module that you will receive back from Tektronix.
1. Remove the Power Supply module. Refer to Power Supply Module on
page 6–21.
2. Disconnect the cable from the Power Supply board that attaches to the Line
Filter board.
3. Remove the eight attaching screws from the Power Supply board. See
Figure 6–16.
To replace the Power Supply board, follow these steps:
1. Install the eight attaching screws into the Power Supply board.
2. Connect the cable from the Line Filter board to the Power Supply board.
3. Install the Power Supply module. Refer to Power Supply Module on
page 6–21.
Remove attaching
screws (8)
Disconnect
cable to Line
Filter board
Figure 6–16: Removing the Power Supply board
6–24
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
Line Filter Board. To remove the Line Filter board, perform the following
procedure:
1. Remove the Power Supply module. Refer to Power Supply Module on
page 6–21.
2. Disconnect the cables from the Line Filter board that attach to the Power
Supply board and the rear-panel fuse holder.
3. Disconnect the two cables from the switch on the power-supply rear panel.
4. Remove the two attaching screws from the rear-panel AC power connector.
5. Remove the three attaching screws from the Line Filter board.
Line Filter board
attaching screws (3)
Connector to Power
Supply board
Connector to
fuse holder
Rear-panel AC power
connector screw (2)
Connectors to
power switch
Figure 6–17: Removing the Line Filter board
To replace the Line Filter board, perform the following procedure:
1. Install the three attaching screws into the Line Filter board.
2. Install the two attaching screws into the rear-panel AC power connector.
3. Connect the cables to the Line Filter board that attach to the Power Supply
board and the rear-panel fuse holder.
TG 2000 Signal Generation Platform Service Manual
6–25
Removal and Replacement
4. Install the Power Supply module. Refer to Power Supply Module on
page 6–21.
Fuse Holder. To remove the fuse holder, perform the following procedure:
1. Remove the Power Supply module. Refer to Power Supply Module on
page 6–21.
2. Disconnect the fuse-holder cable from the Line Filter board.
3. Slide the plastic cover off of the fuse holder.
4. Unsolder the two wires from the fuse holder.
5. Remove the attaching nut and washer from the fuse holder using a 9/16-inch
wrench.
6. Slide the fuse holder out through the front of the rear panel.
To replace the fuse holder, perform the following procedure:
1. Slide the fuse holder in through the front of the rear panel. See Figure 6–18.
2. Install the attaching nut and washer from the fuse holder using a 9/16-inch
wrench.
3. Solder the two wires from the cable on the Line Filter board to the fuse
holder. See Figure 6–18.
4. Slide the plastic cover onto the fuse holder.
6–26
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
Fuse holder
Connecter
Fuse holder
Unsolder
Plastic cover
Washer
Nut
Figure 6–18: Installing the fuse holder
5. Connect the fuse-holder cable to the Line Filter board.
6. Install the Power Supply module. Refer to Power Supply Module on
page 6–21.
CPU Module Assembly
The CPU module assembly contains replaceable subparts. Procedures for
removing the subparts are included below.
CPU Module. To remove the CPU module, perform the following procedure:
1. Remove the top cover. Refer to Top Cover on page 6–11.
2. Remove the attaching screw from the front of the CPU module and loosen
the lower rear-panel screw of the CPU module.
3. Disconnect the power-supply cable, the front-panel cable, and the GP1 cable
if a GP1 module is installed.
4. Lift the CPU module from the mainframe.
TG 2000 Signal Generation Platform Service Manual
6–27
Removal and Replacement
5. Disconnect the floppy cable from the CPU module. See Figure 6–19.
To replace the CPU module, perform the following procedure:
1. Connect the floppy cable to the CPU module. See Figure 6–19.
2. Install the CPU module into the mainframe.
Lift tab to
release cable
Figure 6–19: Removing the CPU module floppy cable
3. Connect the power-supply cable, the front-panel cable, and the GP1 cable if
a GP1 module is installed.
4. Install the attaching screw into the front of the CPU module and tighten the
lower rear-panel screw of the CPU module.
5. Replace the top cover. Refer to Top Cover on page 6–11.
CPU Memory Board. To remove the CPU Memory board, perform the following
procedure:
1. Remove the CPU module. Refer to CPU Module on page 6–27.
2. Remove the memory board from the CPU module. See Figure 6–20.
6–28
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
CPU module
CPU Memory board
Click in
CPU Memory
board
Rotate up
Push in
Figure 6–20: Installing the CPU Memory board
To replace the CPU Memory board, perform the following procedure:
1. Install the CPU Memory board into the CPU module. See Figure 6–20.
2. Install the CPU module. Refer to CPU Module on page 6–27.
Date/Time Clock. To remove the date/time clock, perform the following
procedure:
1. Remove the CPU module. Refer to CPU Module on page 6–27.
2. Remove the date/time IC from the CPU module. See Figure 6–21.
TG 2000 Signal Generation Platform Service Manual
6–29
Removal and Replacement
CPU module
U49
Date/time IC
Figure 6–21: Removing the date/time clock from the CPU module
To replace the date/time clock, perform the following procedure:
1. Install the date/time IC into its socket. Check for bent pins.
2. Install the CPU module. Refer to CPU Module on page 6–27.
6–30
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
Clock Module Assembly
The Clock module assembly contains replaceable subparts. Procedures for
removing the subparts are included below.
Clock Module. To remove the Clock module, perform the following procedure:
1. Remove the top cover. Refer to Top Cover on page 6–11.
2. Remove the attaching screw from the front of the Clock module and loosen
the lower rear-panel screw of the Clock module.
3. Disconnect the cable from the AGL1 module if one is installed.
4. Lift the Clock module from the mainframe.
NOTE. If you return the Clock module to Tektronix for module exchange, do not
return any attaching cables. The cables will not be included in the exchange
module that you will receive back from Tektronix.
To replace the Clock module, perform the following procedure:
1. Install the Clock module into the mainframe.
2. Connect the cable from the AGL1 module if one is installed. Refer to the
manual for the AGL1 module for installation instructions.
3. Install the attaching screw into the front of the Clock module and tighten the
lower rear-panel screw on the Clock module.
4. Install the top cover. Refer to Top Cover on page 6–11.
Clock Board Oscillator. To remove the Clock board oscillator, perform the
following procedure:
1. Remove the Clock module. Refer to Clock Module on page 6–31.
2. Remove the two attaching screws from the oscillator cover.
3. Lift up the oscillator cover.
4. Remove the oscillator from the connector.
To replace the Clock board oscillator, perform the following procedure:
1. Install the oscillator onto the Clock board. See Figure 6–22.
2. Align the oscillator cover and install the two attaching screws.
3. Install the Clock module. Refer to Clock Module on page 6–31.
TG 2000 Signal Generation Platform Service Manual
6–31
Removal and Replacement
Remove screws (2)
Oscillator cover
Oscillator
Gasket
Clock module
Align
Baseplate
Connector
Figure 6–22: Installing the Clock board oscillator
Fans
There are two fans in the TG 2000 Platform mainframe. Procedures for removing
each fan are included below.
Power Supply Fan. To remove the Power Supply board fan, perform the
following procedure:
1. Remove the Power Supply module. Refer to Power Supply Module on
page 6–21.
2. Remove the four attaching screws from the outside of the chassis and lift the
fan from the chassis. See Figure 6–23.
To replace the Power Supply board fan, perform the following procedure:
1. Position the fan so that the air-flow indicator on the fan housing points to the
outside of the instrument and so that the fan cable is on the top of the fan.
2. Install the four attaching screws.
3. Install the Power Supply module. Refer to Power Supply Module on
page 6–21.
6–32
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
Power supply fan
Remove screws (4)
Figure 6–23: Removing the Power Supply board fan
Clock Module Fan. To remove the Clock module fan, perform the following
procedure:
1. Remove the Clock module. Refer to Clock Module on page 6–31.
2. Disconnect the fan cable from the Backplane board.
3. Remove the four attaching nuts from the Clock module fan and lift the fan
from the chassis. See Figure 6–24.
To replace the Clock board fan, perform the following procedure:
1. Position the fan so that the air-flow indicator on the fan housing points
toward the outside of the instrument and so that the fan cable is on the
bottom of the fan.
2. Install the four attaching nuts.
TG 2000 Signal Generation Platform Service Manual
6–33
Removal and Replacement
Clock board fan
Remove nuts (4)
Cable retaining clip
Connector
Backplane board
Figure 6–24: Removing the Clock board fan
3. Connect the fan cable to the connector on the Backplane board. Dress the fan
cable behind the retaining clip. See Figure 6–24.
4. Install the Clock module. Refer to Clock Module on page 6–31.
Backplane Board and
Shield
To remove the Backplane board and shield, perform the following procedure:
1. Remove the top cover. Refer to Top Cover on page 6–11.
2. Remove the Power Supply module. Refer to Power Supply Module on
page 6–21.
3. Remove the CPU module. Refer to CPU Module on page 6–27.
4. Remove the Clock module. Refer to Clock Module on page 6–31.
5. Remove all installed generator or special function modules.
6. Disconnect the backup battery cable and Clock module fan cable from the
Backplane board.
7. Remove the 12 attaching screws on the Backplane board and lift the circuit
board from the chassis. See Figure 6–25.
6–34
TG 2000 Signal Generation Platform Service Manual
Removal and Replacement
Remove screws (12)
Backplane board
Backplane shield
Figure 6–25: Removing the Backplane board
To replace the Backplane board and shield, perform the following procedure:
1. Align the shield under the Backplane board and install the 12 attaching
screws on the Backplane board.
2. Connect the backup battery cable and Clock module fan cable to the
Backplane board.
3. Install the Clock module. Refer to Clock Module on page 6–31.
4. Install the CPU module. Refer to CPU Module on page 6–27.
5. Install the Power Supply module. Refer to Power Supply Module on
page 6–21.
6. Install the top cover. Refer to Top Cover on page 6–11.
TG 2000 Signal Generation Platform Service Manual
6–35
Removal and Replacement
Backup Battery
To remove the backup battery, perform the following procedure:
CAUTION. To prevent the loss of data, leave the instrument in standby mode when
you replace the backup battery.
1. Remove the front-frame assembly. Refer to Front Frame on page 6–12.
2. Remove the two retaining screws from the battery.
3. Disconnect the two wires from the battery.
To replace the backup battery, perform the following procedure:
1. Connect the two wires to the battery. See Figure 6–26.
2. Install the two retaining screws into the battery.
3. Install the front-frame assembly. Refer to Front Frame on page 6–12.
Brown
Red
Retaining screws (2)
Battery wires pass
through grille here
Figure 6–26: Replacing the battery
6–36
TG 2000 Signal Generation Platform Service Manual
Troubleshooting Procedures
The troubleshooting procedures enable you to isolate faults within the TG 2000
Platform mainframe to the module level. This is limited to modules that are part
of the mainframe, such as the power supply and CPU. To troubleshoot faults
involving another module, such as a generator module, refer to the service
manual for that module.
Equipment Required
The equipment listed in Table 6–3 is required for troubleshooting.
Table 6–3: Equipment required for troubleshooting
Equipment
Minimum requirements/example
Torx screwdriver handle
Accepts Torx-driver bits
T-10 and T-20 Torx tips
Torx-driver bit for T-10 and T-20 screw heads
Cross-tip screwdriver
Voltmeter with probes
Accurate to two decimal places and measure AC voltage of 900
VRMS. For example, the Tektronix DM2510 Digital Multimeter.
Floppy disk
MS–DOS preformatted, 3.5 inch
General Troubleshooting Procedures
This section contains general troubleshooting instructions and procedures to use
when you begin to troubleshoot suspected faults with the instrument. If the
instrument does not boot up or if the display is not working, refer to Fault
Symptom Table on page 6–40.
Before you begin to troubleshoot suspected faults, perform the following steps if
the instrument is able:
CAUTION. To prevent data loss, backup the instrument before you begin any
troubleshooting procedures. Refer to Instrument Backup below for instructions.
1. Back up the instrument if it is already on. Refer to Instrument Backup on
page 6–38.
2. Write the Console Ring file to disk. Refer to Saving the Console Ring File to
Disk on page 6–39.
TG 2000 Signal Generation Platform Service Manual
6–37
Troubleshooting Procedures
3. Turn the instrument off and then back on.
4. Write the Console Ring file to disk again (rerun the loaded sequence). Name
this Console Ring file differently than the first Console Ring file.
5. Read the bootup messages and watch for errors. If errors occur, remove the
top cover from the instrument and check that all cable connections are good.
Check that the connector pins on the Backplane board are not bent or
damaged and that all module subassemblies are properly seated.
6. If the CPU module fails the confidence test, refer to CPU Confidence Test
Codes on page 6–40.
7. Refer to the Troubleshooting section of the service manual for any generator
module that has error messages displayed during the bootup process.
8. Refer to Fault Symptom Table on page 6–40.
Instrument Backup
Perform the following procedure before you begin to troubleshoot the TG 2000
Platform mainframe. If the floppy drive is not functioning, refer to Figure 6–33
on page 6–44. After the problem is solved, restore instrument signals from the
backup disks.
1. Load the Troubleshooting disk (supplied in this manual) into the floppy
drive.
2. Press the front-panel Sequences button.
3. Touch File Utilities, and then touch Add Sequences from Disk.
4. Select the tgbackup.seq sequence file, and then touch Start Load.
5. Touch OK, Quit, and then Quit again.
6. Touch Sequences and then select the tgbackup.seq file to run.
7. Touch Run and then follow the instructions on the screen.
8. To restore the instrument setup after troubleshooting, load and run the
tgrstore.seq file. Insert the back up disk(s) that you created when prompted
by messages on screen. Disks do not have to be inserted in any particular
order.
6–38
TG 2000 Signal Generation Platform Service Manual
Troubleshooting Procedures
Saving the Console Ring
File to Disk
The TG 2000 Platform mainframe displays module diagnostic information
during instrument power up. Any error messages are written to an internal file
called the console ring file. Tektronix technicians can use the information in the
console ring file to help troubleshoot a malfunctioning module.
NOTE. Write the console ring file to disk before performing troubleshooting to
prevent the troubleshooting routines from overwriting the console ring file.
Write the file as follows:
1. Load the Troubleshooting disk (supplied with the TG 2000 Signal Generation Platform Service Manual) into the floppy drive. Press the front-panel
Sequences button.
2. Touch File Utilities, and then touch Add Sequences from Disk.
3. Select the consbak.seq sequence file and then touch Start Load.
4. Touch OK, Quit, and then Quit again.
5. Touch Sequences and then select the consbak.seq file to run (use the Select
key).
6. Touch Run. Insert a blank disk when prompted, and touch Quit. Label this
disk #1.
7. Turn the instrument off and then back on from the front panel. Wait until the
instrument has completed its power up process.
8. Write the console ring file to disk again, using a different disk. Label this
disk #2.
9. Read the console ring file power up messages. If there are errors, refer to the
Fault Symptom Table on page 6–40.
Returning Modules to
Tektronix
When you return a mainframe or module to Tektronix for repair or replacement,
be sure to include the following:
The disks containing the console ring files.
Information about whether or not the module passed diagnostics, the
highest number reached for that module, and any error messages.
Description of the problem, including which troubleshooting flow chart
you used.
TG 2000 Signal Generation Platform Service Manual
6–39
Troubleshooting Procedures
CPU Confidence Test
Codes
The CPU diagnostic LED displays an error code when the CPU module fails a
confidence test. The confidence tests are run sequentially and stop when an error
is found. If an error is found during the third confidence test, tests four, five, and
six are not run.
Table 6–4: CPU confidence test codes
Error code
Confidence test
Action required
1
Verify LCD controller is responding
Replace CPU module
2
Test LCD memory
Replace CPU module
3
Test NVRAM
Replace CPU module
4
Test DRAM
Check CPU Memory board seating. Replace CPU Memory board or CPU module.
5
Test FLASH
Replace CPU module
6
Test floppy drive
Check floppy drive. Replace CPU module.
Fault Symptom Table
Before proceeding, be sure you have saved the console ring file as indicated in
General Troubleshooting on page 6–39.
Use the fault symptom table when the instrument does not boot up or has display
problems, or after you have performed the general troubleshooting procedure on
page 6–37.
Locate your fault symptom in Table 6–5 and go to the indicated flowchart to
isolate the faulty module.
Table 6–5: Fault symptom table
6–40
Symptom
Flowchart
Instrument does not boot up properly or has bad display
page 6–41
Backlight does not illuminate
page 6–42
Front panel does not function
page 6–43
Locked LED does not illuminate
page 6–44
Floppy drive does not operate
page 6–44
Instrument hot or fans do not operate
page 6–45
The correct time is not stored
page 6–46
Signal noise in slots 9 and 10 (SN B010391 and below only)
page 6–46
Instrument loses its signal and operating memory
page 6–47
Front-panel knob does not function properly
page 6–48
TG 2000 Signal Generation Platform Service Manual
Troubleshooting Procedures
Troubleshooting Flowcharts
Follow the steps in the appropriate flowchart to isolate the faulty module. Each
flowchart is directly related to a fault symptom listed in Table 6–5.
Use this procedure when the
instrument does not boot up
properly or has bad display.
Set the rear-panel power
switch to on, and then use
the front-panel switch to turn
the instrument on.
Check that the Line Selector switch is set correctly for
the local mains voltage.
Does the
front panel
light up?
Check that the rear-panel fuse is not blown and is the
correct rating for your local mains voltage.
No
Check the power supply cables: (from the Line Filter
board to the Power Supply board, from the Power Supply
board to the Backplane board, from the Power Supply
board to the CPU module).
Yes
Did the LCD
display backlight
illuminate?
No
Go to
Figure 6–29.
Measure the power supply
voltages. See Figure 6–28.
Yes
Does the front
panel function?
No
Go to
Figure 6–31.
Yes
Check the Front Panel board cables.
Replace the LCD Display module.
Are the power
supply voltages
ok?
No
Replace the Power Supply
module.
Yes
Replace the CPU module or
the Front Panel board.
Replace the Front Panel board.
Replace the CPU module.
Figure 6–27: Instrument does not boot up properly
TG 2000 Signal Generation Platform Service Manual
6–41
Troubleshooting Procedures
–2V
Oscillator
–5V –15V
+5V
+15V
GND
Figure 6–28: Measuring the power supply voltages on the clock board
Use this procedure when
the backlight does not
illuminate.
Measure the backlight voltage. See
Figure 6–30.
Remove the front frame assembly,
leaving the front-panel cable
connected. Disconnect the CCT
cable from the LCD Display module.
Measure for approximately
900 VRMS across pins 4 and 5
(closest pins to the display module)
of the high voltage board on the
back of the Front Panel board.
Is the backlight
voltage ok?
No
Replace the Front Panel board.
Yes
Replace the LCD Display
module.
Figure 6–29: Backlight does not illuminate
6–42
TG 2000 Signal Generation Platform Service Manual
Troubleshooting Procedures
Disconnect
Pin 5 (GND)
Pin 4 (out)
Figure 6–30: Measuring the LCD Display module high voltage
Use this procedure when
the front panel does not
function.
Check that there are no stuck
front-panel buttons. If buttons
are sticking, adjust the mounting
of the Front Panel board.
Check that the front-panel ribbon
cable is properly connected.
Replace the LCD Display
module.
Replace the Front Panel board.
Replace the CPU module.
Figure 6–31: Front panel does not function
TG 2000 Signal Generation Platform Service Manual
6–43
Troubleshooting Procedures
Use this procedure when
the Locked LED does not
illuminate.
Does the LED
illuminate during
boot up?
No
Check the front-panel cables.
Replace the Front Panel board.
Yes
Replace the AGL1 module.
Figure 6–32: Locked LED does not illuminate
Use this procedure when
the floppy drive does not
operate properly.
Check that the Floppy drive to
CPU module cable is ok and
oriented properly. See
Figure 6–11.
Is the cable ok?
No
Replace the cable.
Yes
Replace the floppy drive.
Replace the CPU module.
Figure 6–33: Floppy drive does not operate properly
6–44
TG 2000 Signal Generation Platform Service Manual
Troubleshooting Procedures
Use this procedure when
the instrument is hot or
the fans do not operate.
Check that the instrument fan
exhausts are not blocked and
that the fans are blowing air.
Are the fans
blowing air?
Check that the instrument is
operating within the
environmental specifications.
Yes
No
Are the
power supply
indicator LEDs
illuminated? See
Figure 6–38.
Yes
If the over-temperature (OT) or
over-voltage (OV) LEDs illuminate, you
must turn off the rear-panel power
switch and then turn the power back on
to reset the power supply.
If the +5 V LED is illuminated, the +5 V
supply is ok.
If one of the three red LEDs comes on,
replace the Power Supply module.
No
Check that the fan power wires
are connected .
Check the connector pins for the
fan jumper wires for 12 V.
Was the fan
voltage correct?
Yes
Replace the fan.
No
Check the cables from the
Power Supply module to the
Backplane board.
Replace the Power Supply
module.
Figure 6–34: Instrument is hot or the fans do not operate
TG 2000 Signal Generation Platform Service Manual
6–45
Troubleshooting Procedures
Use this procedure when
the correct time is not
stored.
Reset the time through the
front-panel Utilities button menu.
Turn off the instrument using the
rear-panel switch and turn it back on.
Is the date/time
clock correct?
Yes
The problem may be user error
or an intermittent problem with
either the date/time IC or the
CPU module.
No
Replace date/time IC on the CPU module. Refer
to Date/Time Clock on page 6–29.
Replace the CPU module.
Figure 6–35: Correct time is not stored
Use this procedure when
there is signal noise in
mainframe slots 9 and 10.
(SN B010391 and below
only)
Check to see if the grounding strap is
installed on the Power Supply module.
See Figure 6–13 on page 6–21.
Is the wire strap
installed?
Yes
Check that the connector pins on the
Backplane board are not damaged or bent.
Move the module from slots 9 and 10 to
another open slot.
No
Install the grounding strap kit
(Tektronix part number
040–1522–XX).
Is there still
signal noise from
the module in
question?
Yes
Replace the
module in
question.
No
Replace the Power Supply module
or replace the Backplane board.
Figure 6–36: Signal noise in mainframe slots 9 and 10
6–46
TG 2000 Signal Generation Platform Service Manual
Troubleshooting Procedures
Use this procedure when
the instrument loses its
signal and operating
memory during rear-panel
power off.
No
Is more than one
module affected?
Check that the Backplane board pins are
not bent on the affected module.
Move the affected module to another slot.
Yes
Check that the backup battery
wires are connected.
Turn off the rear-panel power
switch and measure the backup
battery voltage (+4.2 V).
Does the affected
module operate in
the new slot?
No
Replace the affected module.
Yes
Replace the Backplane board.
Check Power Supply charging circuit.
Is the battery
voltage ok?
No
Remove the cable from J2 on the Power
Supply board and measure pin 7 (See
Figure 6–38) for +4.7 V with rear panel
power on, +0.5 V with rear-panel power off.
Yes
Check the Backplane board
for bent pins.
Is the battery
charging circuit
ok?
Yes
The problem is likely the
backup battery, but it could
be the Backplane board or
the CPU module.
No
Replace the Power Supply module.
Figure 6–37: Instrument loses signal and operating memory during rear-panel
power off
TG 2000 Signal Generation Platform Service Manual
6–47
Troubleshooting Procedures
Power Supply
board
Indicator LEDs
Line Filter board
J2
OT
OV
OI
+5V
Pin 7
OT – Over temperature
OV – Over voltage
OI – Over current
Figure 6–38: Measuring the battery charging circuit
Use this procedure when
the front-panel knob is not
functioning properly.
Is the front panel
operational?
No
Go to Figure 6–31.
Yes
Check that the encoder to
front-panel knob cable is
connected.
Check that the encoder is ok.
Is the encoder
ok?
No
Replace the encoder.
Yes
Replace the Front Panel board.
Figure 6–39: Front-panel knob does not function properly
6–48
TG 2000 Signal Generation Platform Service Manual
Options
The only instrument options available with the TG 2000 Platform mainframe are
the power cord options. Check the module manuals for information on options
available with modules.
You can purchase the mainframe with one of the power cord options shown in
Table 7–1. Power cord part numbers are shown in the Replaceable Mechanical
Parts list.
Table 7–1: Power cord identification
Plug configuration
TG 2000 Signal Generation Platform Service Manual
Normal usage
Option number
North America
125 V/15A Plug
NEMA 5-15P
Standard
Europe
230 V
A1
United Kingdom
230 V
A2
Australia
230 V
A3
North America
230 V
A4
Switzerland
230 V
A5
7–1
Options
7–2
TG 2000 Signal Generation Platform Service Manual
Replaceable Electrical Parts
The electrical modules for the TG 2000 Signal Generation Platform, such as the
battery, circuit boards, and fuses, are included in the Replaceable Mechanical
Parts list. Since component-level repair is not supported, individual electrical
components are not listed.
TG 2000 Signal Generation Platform Service Manual
8–1
Replaceable Electrical Parts
8–2
TG 2000 Signal Generation Platform Service Manual
Diagrams
The diagrams in this section show how the generator modules and special
function modules connect with the mainframe (Backplane board), with each
other, and with other equipment (outputs).
Mainframe Interconnect Diagrams
Figure 9–1 shows the Backplane board (assembly A1), which is located on the
bottom of the mainframe chassis. This board has a total of 11 slots. The diagram
shows how the components of the system, including optional modules, plug into
the Backplane board, and indicates which modules can be plugged into each slot.
Figure 9–2 shows the Front Panel board, Power Supply board and Line Filter
connections and Figure 9–3 shows the Clock module connections.
Modules Interconnect Diagrams
Figures 9–4 through 9–8 show the generator and special function modules with
their respective outputs and connections, including the Backplane board slots to
which each module can be connected.
TG 2000 Signal Generation Platform Service Manual
9–1
Diagrams
A1 Backplane
36
A5
Clock module
14
Slot 1
14
Slot 2
14
Slot 3
14
Slot 4
14
Slot 5
14
Slot 6
14
Slot 7
14
Slot 8
14
Slot 9
14
Slot 10
128
36
A6 AGL1
or
any generator module
128
36
A6 AGL1
or
any generator module
128
36
Any generator
module
128
36
Any generator
module
128
36
Any generator
module
128
36
Any generator
module
128
36
Any generator
module
128
36
Any generator
module
128
36
A12 GP1
or
any generator module
128
36
A3
CPU board
J1
A4
J10
Power supply
J11
14
Slot 11
128
11
J34
11
J37
3
Left fan
J36
Figure 9–1: Backplane board connections
9–2
TG 2000 Signal Generation Platform Service Manual
Diagrams
3
Right fan
A13
4
J2
J5
A4
J10
J34
A1
Backplane board
Power Supply
board
J11
J9
11
11
J36
J2
Line filter
To AC power
10
J2
SERIAL PORT
J2
Slot 11
A3
PARALLEL PORT
A12
P1, P2, P3
CPU module
26
J14
26
J9
26
Floppy disk
drive
J20
GPI module
J3
A2
Front Panel board
J11
2
J12
J13
14
16
Memory board
Display module
Figure 9–2: CPU, Front Panel board, Power Supply board and Line Filter connections
TG 2000 Signal Generation Platform Service Manual
9–3
Diagrams
W123
Oscillator assembly
J1
10
A6
AGL1 module
J105
1
J107
J100
A1
Backplane board
Slot 2
P1, P2, P3
A5
Slot 1
Clock module
A6
AGL1 module
J105
1
J101
Slot 3
Figure 9–3: Clock connections
Delay
board
35
A6
A1
AGL1 module
Backplane board
REF1
P1, P2, P3
Rear-panel
connectors
Slot 2 or 3
A5
REF2
REF3
(75 W term.)
Clock module
J105
VCO TUNE
J100 (GLSLOT2IN)
or
J101 (GLSLOT3IN)
J100
VIDEO TP
Figure 9–4: AGL1 module connections
9–4
TG 2000 Signal Generation Platform Service Manual
Diagrams
Delay
board
Line
RAM
35
CH 1
J4
CH 2
J13
CH 3
J18
Line
RAM
80
80
A7
A1
AVG1 module
Backplane board
P1, P2, P3
Slot 2 - 10
Rear-panel
connectors
TRIGGER
J7
Figure 9–5: AVG1 module connections
Delay
board
35
OUTPUT
J1
A1
A11
Backplane board
AWVG1 module
OUTPUT
J2
OUTPUT
J3
INPUT
J4
P1, P2, P3
Slot 2 - 10
Rear-panel
connectors
Figure 9–6: AWVG1 module connections
TG 2000 Signal Generation Platform Service Manual
9–5
Diagrams
J104
CLOCK OUT
A1
A10
Backplane board
BG1 module
OUTPUT 1
J103
OUTPUT 2
J102
OUTPUT 3
J101
P1, P2, P3
Slot 2 - 10
Rear-panel
connectors
Figure 9–7: BG1 module connections
Rear-panel
connector
A12
GPIB OUTPUT
J20
CPU module
A3
GP1 module
26
J101
Figure 9–8: GP1 module connections
9–6
TG 2000 Signal Generation Platform Service Manual
Diagrams
J14
SERIAL OUTPUT 1
A1
A8
Backplane board
DVG1 module
P1, P2, P3
J15
SERIAL OUTPUT 2
Slot 2 - 10
Rear-panel
connectors
TRIGGER
PARALLEL OUTPUT
J7
25
J17
Figure 9–9: DVG1 module connections (standard)
NOTE. Figure 9–10 shows the connections with Option S1 installed as shipped.
For information about using alternate connections, refer to the DVG1 Digital
Video Generator User Manual.
Alternate connection
J1
A9
Option S1
J2
SERIAL OUTPUT 2
J3
40
Rear-panel
connectors
J14
SERIAL OUTPUT 1
J16
A1
Backplane board
A8
DVG1 module
Alternate connection
J15
TRIGGER
J7
PARALLEL OUTPUT
25
P1, P2, P3
Slot 2 - 10
J17
Figure 9–10: DVG1 module connections (with Option S1 installed as shipped)
TG 2000 Signal Generation Platform Service Manual
9–7
Diagrams
9–8
TG 2000 Signal Generation Platform Service Manual
Replaceable Parts
This section contains a list of the replaceable modules for the TG 2000 Signal
Generation Platform. Use this list to identify and order replacement parts.
Parts Ordering Information
Replacement parts are available through your local Tektronix field office or
representative.
Changes to Tektronix products are sometimes made to accommodate improved
components as they become available and to give you the benefit of the latest
improvements. Therefore, when ordering parts, it is important to include the
following information in your order.
Part number
Instrument type or model number
Instrument serial number
Instrument modification number, if applicable
If you order a part that has been replaced with a different or improved part, your
local Tektronix field office or representative will contact you concerning any
change in part number.
Change information, if any, is located at the rear of this manual.
Module Servicing
Modules can be serviced by selecting one of the following three options. Contact
your local Tektronix service center or representative for repair assistance.
Module Exchange. In some cases you may exchange your module for a remanufactured module. These modules cost significantly less than new modules and
meet the same factory specifications. For more information about the module
exchange program, call 1-800-TEK-WIDE, extension 6630.
Module Repair and Return. You may ship your module to us for repair, after which
we will return it to you.
New Modules. You may purchase replacement modules in the same way as other
replacement parts.
TG 2000 Signal Generation Platform Service Manual
10–1
Replaceable Parts
Using the Replaceable Parts List
This section contains a list of the mechanical and/or electrical components that
are replaceable for the TG 2000 Signal Generation Platform. Use this list to
identify and order replacement parts. The following table describes each column
in the parts list.
Parts List Column Descriptions
Column
Column Name
Description
1
Figure & Index Number
Items in this section are referenced by figure and index numbers to the exploded view
illustrations that follow.
2
Tektronix Part Number
Use this part number when ordering replacement parts from Tektronix.
3 and 4
Serial Number
Column three indicates the serial number at which the part was first effective. Column four
indicates the serial number at which the part was discontinued. No entries indicates the part is
good for all serial numbers.
5
Qty
This indicates the quantity of parts used.
6
Name & Description
An item name is separated from the description by a colon (:). Because of space limitations, an
item name may sometimes appear as incomplete. Use the U.S. Federal Catalog handbook
H6-1 for further item name identification.
7
Mfr. Code
This indicates the code of the actual manufacturer of the part.
8
Mfr. Part Number
This indicates the actual manufacturer’s or vendor’s part number.
Abbreviations
Mfr. Code to Manufacturer
Cross Index
10–2
Abbreviations conform to American National Standard ANSI Y1.1–1972.
The table titled Manufacturers Cross Index shows codes, names, and addresses
of manufacturers or vendors of components listed in the parts list.
TG 2000 Signal Generation Platform Service Manual
Replaceable Parts
Manufacturers Cross Index
Mfr.
Code
Manufacturer
Address
City, State, Zip Code
80009
TEKTRONIX, INC.
P.O. BOX 500
BEAVERTON, OR, 97077-0001
06090
RAYCHEM CORP
300 CONSTITUTION DR
MENLO PARK, CA 94025–1111
06666
GENERAL DEVICES
PO BOX 39100
INDIANAPOLIS, IN 46239
06915
RICHCO
5825 N TRIPP AVE
P.O. BOX 804238
CHICAGO, IL 60646
01536
TEXTRON INC
1818 CHRISTINA ST
ROCKFORD, IL 61108
0B0A9
DALLAS SEMICONDUCTOR
4350 BELTWOOD PKWY S
DALLAS, TX 75244
0JR04
TOSHIBA AMERICA INC.
ELECTRONICS COMPONENTS DIV
9775 TOLEDO WAY
IRVINE, CA 92718
0KB01
STAUFFER SUPPLY CO
810 SE SHERMAN
PORTLAND, OR 97214–4657
1DM20
PARLEX CORP
7 INDUSTRIAL WAY
SALEM, NH 03079
2K262
BOYD CORPORATION
6136 NE 87TH AVENUE
PORTLAND, OR 97220
32559
BIVAR INC
4 THOMAS ST
IRVINE, CA 92718
32997
BOURNS INC
TRIMPOT DIVISION
1200 COLUMBIA AVE
RIVERSIDE, CA 92507–2114
50356
TEAC AMERICA INC
7733 TELEGRAPH RD
PO BOX 750
MONTEBELLO, CA 90640–6537
54186
MICRO POWER SYSTEMS INC
3151 JAY ST
SANTA CLARA, CA 95054
5F520
PANEL COMPONENTS CORP
PO BOX 115
OSKALOOSA, IA 52577–0115
61058
MATSUSHITA ELECTRIC CORP OF AMERICA
PANASONIC INDUSTRIAL CO DIV
TWO PANASONIC WAY
SECAUCUS, NJ 07094
61935
SCHURTER INC
1016 CLEGG CT
PO BOX 750158
PETALUMA, CA 94975–0158
73893
MICRODOT INC
50631 E RUSSELL SCHMIDT BLVD
MT CLEMENS, MI 48045
7X318
KASO PLASTICS INC
11013 A NE 39TH
VANCOUVER, WA 98662
80126
PACIFIC ELECTRICORD CO
747 WEST REDONDO BEACH
PO BOX 10
GARDENA, CA 90247–4203
85480
BRADY USA
NAMEPLATE DIVISION
P O BOX 571
346 ELIZABETH BRADY RD
HILLSBOROUGH, NC 27278
93907
CAMCAR DIV OF TEXTRON INC
ATTN: ALICIA SANFORD
516 18TH AVE
ROCKFORD, IL 611045181
S3109
FELLER U.S. CORPORATION
72 VERONICA AVE
UNIT #4
SOMERSET, NJ 08873
TK0435
LEWIS SCREW CO.
4300 SOUTH RACINE AVENUE
CHICAGO, IL 60609
TK1163
POLYCAST INC
9898 SW TIGARD ST
TIGARD, OR 97223
TK1547
MOORE ELECTRONICS INC
19500 SW 90TH CT
PO BOX 1030
TUALATIN, OR 97062
TK1943
NEILSEN MANUFACTURING INC
3501 PORTLAND RD NE
SALEM, OR 97303
TK2376
CONDUCTIVE RUBBER TECH
22125 17TH AVE SE, SUITE 117
BOTHELL, WA 98021
TK2469
UNITREK CORPORATION
3000 LEWIS & CLARK HWY
SUITE 2
VANCOUVER, WA 98661
TG 2000 Signal Generation Platform Service Manual
10–3
Replaceable Parts
Manufacturers Cross Index (Cont.)
Mfr.
Code
Manufacturer
Address
City, State, Zip Code
TK2541
AMERICOR ELECTRONICS LTD
UNIT–H
2682 W COYLE AVE
ELK GROVE VILLAGE, IL 60007
TK2548
XEROX CORPORATION
DIV OF XEROX CORPORATION
14181 SW MILLIKAN WAY
BEAVERTON, OR 97005
10–4
TG 2000 Signal Generation Platform Service Manual
Replaceable Parts
Replaceable Parts List
Fig. &
Index
Number
Tektronix Part
Number
Serial No.
Effective
Serial No.
Discont’d
Qty
Mfr.
Code
Name & Description
Mfr. Part Number
1–1
211–0725–00
40
SCREW,MACHINE:6–32 X 0.375,FLH TORX
01536
ORDER BY DESCR
–2
200–4137–00
1
COVER,TOP:ALUMINUM
80009
200–4137–00
–3
119–5110–00
1
FAN,DC:TUBEAXIAL,12V,2.40W,80MM X 15MM
61058
FBA08T12H
–4
210–0457–00
4
NUT,PL,ASSEM WA:6–32 X 0.312,STL CD
PL,W/LOCKWASHER
0KB01
ORDER BY DESCR
–5
333–4113–00
3
PANEL,REAR:ALUMINUM
80009
333–4113–00
–6
211–0408–00
12
SCR,ASSEM WSHR:4–40 X 0.250,PNH,STL,ZINC,T–10 TORX
0KB01
211–0408–00
–7
119–5087–00
1
FAN,DC:TUBEAXIAL,12V,120MM X 120MM X 38MM
80009
119–5087–00
–8
210–0458–00
12
NUT,PL,ASSEM WA:8–32 X 0.344,STL CD PL
73893
ORDER BY DESCR
NO 841
–9
212–0189–00
4
SCR,ASSEM WSHR:8–32 X 0.500,PNH,STL,CDPL,T–20 TORX
DR,MACHINE
0KB01
ORDER BY
DESCRIPTION
–10
351–0104–03
1
SL SECT,DWR EXT:12.625 L,W/O HARDWARE
06666
C–720–3 (WITHOUT
HARDWARE)
–11
337–4065–00
1
SHIELD:0.020 FR60 POLY
80009
337–4065–00
–12
671–2870–00
–13
441–2048–01
B010100
441–2048–02
B010392
B010391
1
CIRCUIT BD ASSY:BACKPLANE
80009
671–2870–00
1
CHASSIS:CHASSIS,ALUM,WITH FANS AND BATTERY
80009
441–2048–01
1
CHASSIS:CHASSIS,ALUM,WITH FANS AND BATTERY
80009
441–2048–02
–14
–––––––––––
1
BRACKET:ALUMINUM,CARD GUIDE
(PART OF CHASSIS ASSEMBLY)
–15
337–4068–00
1
SHIELD:SHIELD,0.020 PLASTIC
80009
337–4068–00
–16
211–0507–00
2
SCREW,MACHINE:6–32 X 0.312,PNH,STL CD PL,POZ
TK0435
ORDER BY DESCR
–17
146–0110–00
1
BATTERY:4.0V,2.5A–H LEAD ACID
54186
0819–0010
–18
174–3185–00
1
CA ASSY,PWR:DISCRETE,PSC,2,18 AWG,10.5L
80009
174–3185–00
–19
351–0782–00
11
GUIDE,CKT BD:NYLON,4.5 L
32559
DC–450
–20
343–0298–00
1
STRAP,RETAINING:0.25 DIA CABLE
06915
HUC–4
TG 2000 Signal Generation Platform Service Manual
SEALED BATTERY
10–5
Replaceable Parts
2
1
3
4
5
20
1
19
6
18
7
8
9
10
17
11
1
12
16
8
15
14
13
Figure 10–1: Top cover and chassis assembly
10–6
TG 2000 Signal Generation Platform Service Manual
Replaceable Parts
Fig. &
Index
Number
Tektronix Part
Number
2–1
Serial No.
Effective
Serial No.
Discont’d
Qty
Name & Description
Mfr.
Code
Mfr. Part Number
367–0450–00
2
HANDLE,BOW:CARRYING,3.75 CTR,10–32 THD 1.75 H
80009
367–0450–00
–2
426–2495–00
1
FRAME,FRONT:PLASTIC,POLYCARB
80009
426–2495–00
–3
174–3298–00
1
CA ASSY,SP:RIBBON,LCD,CPR,14,26 AWG,5.0 L
TK2469
174–3298–00
–4
200–4131–00
24
COVER,KEYCAP:PLASTIC,ABS
TK1163
200–4131–00
–5
671–2871–00
1
CIRCUIT BD ASSY:FRONT PANEL
80009
671–2871–00
–6
614–0933–00
1
ASSEMBLY,KIT:LCD DISPLAY MODULE
80009
614–0933–00
–7
211–0408–00
15
SCR,ASSEM WSHR:4–40 X 0.250,PNH,STL,ZINC,T–10 TORX
0KB01
211–0408–00
–8
212–0158–00
4
SCREW,MACHINE:8–32 X 0.375,PNH,STL,CDPL,T–20 TORX
0KB01
ORDER BY DESCR
–9
361–1679–00
1
SPACER:SPACER,CONNECTOR,4682
80009
361–1679–00
–10
311–2486–00
1
RES,VAR,PANEL:5K OHM, +/– 1%,1.5W,1.312D X 0.648L
32997
6657S–457–502
–11
119–4617–00
1
ELASTOMERIC,SW:SILICON RUBBER KEYPAD
TK2376
119–4617–00
–12
337–4055–00
1
SHIELD:SWITCH PROTECTOR SHIELD, PLASTIC,TV GRAY
7X318
337–4055–00
–13
200–4130–00
1
COVER,KEYCAP:PLASTIC,ABS
TK1163
200–4130–00
–14
174–3184–00
1
CA ASSY,SP:RIBBON,CPD,2,26 AWG,8.06,1X 3,0.1 CTR
TK1547
174–3184–00
–15
366–2174–00
1
KNOB:
80009
366–2174–00
TG 2000 Signal Generation Platform Service Manual
10–7
Replaceable Parts
10
9
8
7
6
5
4
3
2
1
15
7
11
12
14
13
10
10
Figure 10–2: Front panel and display
10–8
TG 2000 Signal Generation Platform Service Manual
Replaceable Parts
Fig. &
Index
Number
Tektronix Part
Number
3–1
211–0725–00
–2
337–4066–00
–3
337–3990–01
B010100
337–3990–02
B011100
Serial No.
Effective
–4
211–0840–00
–5
119–5413–01
B010100
119–5677–00
B011100
–6
337–4109–00
B010100
–7
162–0676–00
B011100
–8
174–3135–00
Serial No.
Discont’d
B011099
B011099
B011099
Qty
Name & Description
Mfr.
Code
Mfr. Part Number
6
SCREW,MACHINE:6–32 X 0.375,FLH TORX
01536
ORDER BY DESCR
1
SHIELD,STEEL:DISK DRIVE ASSEMBLY SHIELD
80009
337–4066–00
1
SHIELD,ELEC:DISK DRIVE SHIELD,ALUM
80009
337–3990–01
1
SHIELD,ELEC:0.36 THK STL, ZI PLT,ETCH/CLR
CHROMATEG,TG2000
TK1943
337–3990–02
3
SCREW,MACHINE:M2.6 X 0.45MM PITCH X 4.0MM L,PHILIPS
0KB01
.26C4MXPHY
1
DISK DRIVE:FLOPPY,3.5 INCH, 2M, 0.5 INCH DSDD
80009
119–5413–01
1
DISK DRIVE:FLOPPY,3.5 INCH,1.44MB,0.5 INCH HIGH,
DSDD,FD–04HF–2300
50356
FD–04HF–2300
1
SHIELD:SHIELD,0.020 CLEAR PLASTIC
2K262
337–4109–00
.5 ft.
INSUL SLVG,ELEC:HT SHRINK,0.75 ID
POLYOLEFIN,BLK
06090
VERSAFIT
1
CABLE ASSY,SP:FLAT FLEX,FLX,26,1MM,15.0 L
1DM20
1.00MM–26–15–B
TG 2000 Signal Generation Platform Service Manual
10–9
Replaceable Parts
1
1
2
3
4
5
6
7
8
Figure 10–3: Disk drive assembly
10–10
TG 2000 Signal Generation Platform Service Manual
Replaceable Parts
Fig. &
Index
Number
Tektronix Part
Number
Serial No.
Effective
Serial No.
Discont’d
Qty
Name & Description
Mfr.
Code
Mfr. Part Number
4–
672–1489–00
B010100
B010391
1
MODULE ASSY:POWER SUPPLY,COMPLETE MODULE
80009
672–1489–00
672–1489–01
B010392
1
MODULE ASSY:POWER SUPPLY,COMPLETE MODULE
80009
672–1489–01
–1
337–3938–00
1
SHIELD,ELEC:ALUMINUM
80009
337–3938–00
–2
337–3988–00
1
SHIELD:POWER SUPPLY,POLYCARBONATE,0.020,CLEAR
2K262
337–3988–00
–3
174–3111–00
2
CA ASSY,PWR:FLAT,IDC 22,18 AWG,5.0 L
TK2469
174–3111–00
–4
174–3470–00
1
CA,ASSY,SP:RIBBON,IDC,28 AWG,3.5 L
TK2469
174–3470–00
–5
198–5786–00
1
WIRE SET,ELEC:FUSE
TK1547
198–5786–00
–6
200–0237–04
1
COVER,FUHLR:PLASTIC
0JR05
ORDER BY DESCR
–7
204–0832–00
1
BODY,FUSEHOLDER:3AG & 5 X 20MM FUSES LOWPROFILE
61935
031 1673 (FEU
MODEL)
–8
210–0873–00
1
WASHER,FLAT:0.5 ID X 0.688 OD X 0.047,RBR
0KB01
ORDER BY DESCR
–9
333–4098–00
1
PANEL,REAR:ALUMINUM,POWER SUPPLY,TG2000
TK1943
333–4098–00
–10
159–0342–00
1
FUSE,CARTRIDGE:6 AMP,250V,SLOW BLOW,0.250X 1.250
(FOR 115V OPERATION ONLY)
71400
MDL–6
159–0005–00
1
FUSE,CARTRIDGE:3 AMP,250V,30SEC,UL LISTED,
(FOR 230V OPERATION ONLY)
71400
MSL–3
–11
200–2264–00
1
CAP,FUSEHOLDER:3AG FUSES
61935
FEK 031 1666
–12
174–3554–00
1
CABLE,WIRE:WIRE ASSEMBLY,INCL ROCKER SWITCH
TK2469
174–3554–00
–13
211–0014–00
2
SCREW,MACHINE:4–40 X 0.5,PNH,STL CD PL,POZ
93907
ORDER BY DESCR
–14
131–3573–00
1
CONN,PLUG,ELEC:MALE,W/LOCKING ADAPTER
80126
B–0779
–15
211–0725–00
5
SCREW,MACHINE:6–32 X 0.375,FLH TORX
01536
ORDER BY DESCR
–16
337–3796–01
1
SHIELD,ELEC:0.032 BRASS,C26000,0.5 HARD
80009
337–3796–01
–17
671–2948–00
1
CKT BD ASSY:LINE FILTER
80009
671–2948–00
–18
211–0408–00
11
SCR,ASSEM WSHR:4–40 X 0.250,PNH,STL,ZINC,T–10 TORX
0KB01
211–0408–00
–19
174–3290–00
1
CA ASSY,SP:DISCRETE,CPM,2,18 AWG,35.0 L,1X3,0.156
CTR,RCPT,FRICTION LOCK X 0.25,FEMALE,FAS
TK2469
174–3290–00
–20
671–2873–00
1
CIRCUIT BD ASSY:POWER SUPPLY
80009
671–2873–00
TG 2000 Signal Generation Platform Service Manual
10–11
Replaceable Parts
11
10
7
9
6
5
7
8
4
12
3
13
14
2
16
15
1
17
12
18
19
20
18
Figure 10–4: Power Supply module assembly
10–12
TG 2000 Signal Generation Platform Service Manual
Replaceable Parts
Fig. &
Index
Number
Tektronix Part
Number
5–
Serial No.
Effective
Serial No.
Discont’d
Qty
Name & Description
Mfr.
Code
Mfr. Part Number
672–1471–00
1
MODULE ASSY:CPU,COMPLETE MODULE
80009
672–1471–00
–1
211–0408–00
8
SCR,ASSEM WSHR:4–40 X 0.250,PNH,STL,ZINC,T–10 TORX
0KB01
211–0408–00
–2
211–0725–00
2
SCREW,MACHINE:6–32 X 0.375,FLH TORX
01536
ORDER BY DESCR
–3
671–2872–00
B010100
1
CIRCUIT BD ASSY:CONTROLLER
80009
671–2872–00
671–2872–01
B010689
1
CIRCUIT BD ASSY:CONTROLLER
80009
671–2872–01
–4
156–4383–00
1
IC,MEMORY:CMOS,DRAM,2MEG X
32,70NS,MODULE,422000A32,SIMM72
0JR04
THM322020AS–70
–5
156–3543–00
1
IC,PROCESSOR:CMOS,PERIPHERAL,RTC, CLOCK
CALENDAR WITH RAM & BATTERY
0B0A9
DS1287
–6
337–3937–01
1
SHIELD,ELEC:ALUMINUM W/PLASTIC SHIELD
80009
337–3937–00
–7
333–4099–00
1
PANEL,REAR:ALUMINUM,CONTROLLER
TK1943
333–4099–00
–8
214–3903–01
4
SCR,JACK:4–40 X 0.312 EXT THD,4–40 INT THD,0.188 HEX
0KB01
214–3903–01
B010688
TG 2000 Signal Generation Platform Service Manual
10–13
Replaceable Parts
8
7
6
4
5
3
2
1
Figure 10–5: CPU assembly
10–14
TG 2000 Signal Generation Platform Service Manual
Replaceable Parts
Fig. &
Index
Number
Tektronix Part
Number
6–
Serial No.
Effective
Serial No.
Discont’d
Qty
Name & Description
Mfr.
Code
Mfr. Part Number
672–1472–00
1
MODULE ASSY:CLOCK, COMPLETE MODULE
80009
672–1472–00
–1
211–0408–00
8
SCR,ASSEM WSHR:4–40 X 0.250,PNH,STL,ZINC,T–10 TORX
0KB01
211–0408–00
–2
211–0012–00
2
SCREW,MACHINE:4–40 X 0.375,PNH,STL CD PL,POZ
93907
ORDER BY DESCR
–3
200–4141–00
1
COVER,TOP:POLYSTRNE,SPG422
7X318
200–4141–00
–4
119–4699–00
1
OVEN ASSEMBLY:TG2000
80009
119–4699–00
–5
348–1370–00
1
GASKET:0.062,POLYURETHANE,SPG422
2K262
348–1370–00
–6
432–0174–00
1
COVER,BOTTOM:POLYSTYRNE
7X318
432–0174–00
–7
671–2874–00
1
CIRCUIT BD ASSY:CLOCK
80009
671–2874–00
–8
337–3941–01
1
SHIELD,ELEC:ALUMINUM W/PLASTIC SHIELD
80009
337–3941–00
–9
333–4172–00
1
PANEL,REAR:REAR PANEL,CLOCK,ALUM,5.200 X 1.240
80009
333–4172–00
–10
211–0725–00
4
SCREW,MACHINE:6–32 X 0.375,FLH TORX
01536
ORDER BY DESCR
TG 2000 Signal Generation Platform Service Manual
10–15
Replaceable Parts
3
8
9
10
4
2
5
7
6
1
10
Figure 10–6: Clock assembly
10–16
TG 2000 Signal Generation Platform Service Manual
Replaceable Parts
Fig. &
Index
Number
Tektronix Part
Number
Serial No.
Effective
Serial No.
Discont’d
Qty
7–
Name & Description
Mfr.
Code
Mfr. Part Number
80009
003–1604–00
STANDARD ACCESSORIES
003–1604–00
159–0005–00
1
TOOLS,SMALL:TORX INSERT BIT,1/4 HEX SHK,T–10
1
FUSE,CARTRIDGE:3A,250V
(230V OPERATION ONLY)
159–0342–00
1
FUSE,CARTRIDGE:6A,250V
(115V OPERATION ONLY)
333–4113–00
–1
1
PANEL:REAR
1
TRK,SL OUT SECT:STATIONARY &INTERMEDIATE
06666
351–0636–00
1
TRK,SL OUT SECT:STATIONARY &INTERMEDIATE
06666
351–0751–01
070–9108–00
1
MANUAL,TECH:USERS,TG2000
80009
070–9108–00
070–9267–00
1
MANUAL,TECH:USERS,SDP2000 W/ SDP2000 SOFTWARE
80009
070–9267–00
161–0216–00
1
CABLE ASSY,PWR:3,18 AWG,2.5M L,BLACK
80126
C7120–25M–BL
351–0636–00
B010100
351–0751–01
B010188
B010187
(STANDARD ONLY)
OPTIONAL ACCESSORIES
–2
161–0215–00
1
CABLE ASSY,PWR:3,0.75MU,2.5MM L,GREY
(EUROPEAN OPTION A1 ONLY)
80126
0–5335–008–GY
–3
161–0066–10
1
CABLE ASSY,PWR:3,1.0 MM SQ,250V/10A,2.5 METER
(UNITED KINGDOM OPTION A2 ONLY)
TK2541
ORDER BY DESCR
–4
161–0066–11
1
CABLE ASSY,PWR:3,1.0MM SQ,250V/10A,2.5 METER
(AUSTRALIAN OPTION A3 ONLY)
80126
ORDER BY DESCR
–5
161–0066–12
1
CABLE ASSY,PWR:3,18 AWG,250V/10A,98 INCH
(NORTH AMERICA OPTION A4 ONLY)
S3109
ORDER BY DESCR
–6
161–0154–00
1
CABLE ASSY,PWR:3,1.0MM SQ,250V/10A,2.5 METER
(SWISS OPTION A5 ONLY)
5F520
86515030
070–9299–00
1
MANUAL,TECH:SERVICE,TG2000
80009
070–9299–00
070–9286–00
1
CIRCUIT BD:SERVICE EXTENDER
80009
070–9286–00
TG 2000 Signal Generation Platform Service Manual
10–17
Replaceable Parts
1
2
3
6
5
4
Figure 10–7: Accessories
10–18
TG 2000 Signal Generation Platform Service Manual
Index
A
D
AC power source, 1–3
Accessories, 1–2, 10–16
Adding signals from a disk, 2–16
Adjust screen contrast, 2–10
Adjustment procedures, 5–1
After repair adjustments, 6–4
AGL1 module connections, 9–4
Arrow buttons, 2–8
AVG1 module connections, 9–5
AWVG1 module connections, 9–5
Delay, 3–5
Deleting signals, 2–18
Diagrams, interconnect, 9–1
Dimensions, 1–3
Disk drive
check operation, 4–3
description, 3–2
replacing, 6–18
using, 2–13
Display features, 2–10
hourglass, 2–11
icons, 2–10
list box, 2–10
page, 2–11
quit/save, 2–11
reset, 2–11
slot #, 2–10
status bar, 2–10
window title, 2–10
Downloading signals, 2–15, 2–16
from remote, 1–2
DVG1 module connections, 9–7
B
Backplane board connections, 9–2
Backup battery, description, 3–2
Backup power, if lost, 2–21
Batteries
charging, 2–21
replacing, 6–36
BG1 module connections, 9–6
Block diagram, 3–1, 3–4
C
Calibration, 2–18, 5–2
Certifications and compliances, 1–6
Characteristics tables, 1–3
Charging the batteries, 2–21
Cleaning, 6–3
Clearance for cooling, 1–4, 2–1
Clock
frequency check, 4–7
signals, 3–3
specifications, 1–5
Clock board, connections, 9–4
Connectors, rear-panel, 2–19
Cooling clearance, 1–4, 2–1
CPU
confidence test codes, 6–40
configuration switch, 2–2, 2–3
connections, 9–3
function (system control), 3–1
module check, 4–3
Creating new signals, 1–1
TG 2000 Signal Generation Platform Service Manual
E
Electrical installation, 2–1
Electrostatic damage, 6–2
Environmental characteristics, 1–3
External reference genlock, 3–4
F
Fans
operation check, 4–3
replacing, 6–32
Fault symptom table, 6–40
File types, supported, 2–13
Firmware version, displayed in Utilities window, 2–7
Frame reset signals, 3–3
Front Panel Enable button, 2–9
Front-panel
controls locked, 2–9
illustration, 2–7
interface check, 4–5
Index–1
Index
Front-panel board connections, 9–3
Fuse, 2–2
Fuse holder, replacing, 6–26
Fuse part numbers, 10–16
G
GP1 module connections, 9–6
GPIB interface, 2–10, 2–20
H
Help window, 2–7
Hourglass, 2–11
I
Icons, 2–10
Installation, 2–1
Interconnect diagrams, 9–1
K
Keypad, 2–8
Knob, 2–8
L
LCD contrast check, 4–6
LCD display screen, 2–10
Line filter, connections, 9–3
Line voltage setting, 2–2
List box, 2–10
Loading signals, 2–15, 2–16
Locked LED indicator, 2–7
N
Navigation controls, 2–8
O
Operating information, 2–6
Option S1, 1–1
Optional accessories, 1–2, 10–16
Options, 7–1
Oscillator, adjustment, 5–5
P
Page icon, 2–11
Parallel interface, 2–9, 2–20
Parts list, 10–4
Parts ordering information, 10–1
Performance verification, 4–1
verification interval, 4–1
Physical dimensions, 1–3
Power cords, 7–1
Power source, 1–3
Power supply, 3–2
adjustment, 5–3
voltages, 5–4, 6–42
Power supply board, connections, 9–3
Power switch
front panel, 2–10
rear panel, 2–2
Power-on procedure, 2–21
Presets, 2–13
Q
Quit/Save, 2–11
M
R
Maintenance, 6–1
Memory, 3–2
Module
exchange, 10–1
hierarchy, 2–12
memory, 2–12, 3–2
parameters, 2–12
repair, 10–1
timing delay, 3–4
Modules, interconnect diagrams, 9–1
Rackmount
installation, 2–3, 2–4
removal, 2–5
Rear-panel connectors, 2–19
Remote button, 2–9
Remote control, description, 3–2
Remote interface
GPIB, 2–10, 2–20
parallel, 2–9, 2–20
serial, 2–9, 2–20
Index–2
TG 2000 Signal Generation Platform Service Manual
Index
Remote port, check operation, 4–6
Removal and replacement procedures, 6–9
Repackaging, 6–4
Replaceable Parts List, 10–4
Replacing
batteries, 6–36
disk drive, 6–18
fans, 6–32
fuse holder, 6–26
Replacing signals from disk, 2–15
Reset, 2–11
RS-232 interface, 2–20
S
Safety certifications, 1–6
Saving signals to disk, 2–13
Screen contrast, 2–10
Select button, 2–8
Selecting test signals, 2–12
Self calibration, 2–18, 5–2
Sequences, 2–13
Serial interface, 2–9, 2–20
Shared module memory, 2–12
Signal memory, 3–2
Signal parameters, 2–12
Signal sets, 2–13
Signals
adding, 2–16
backing up before removing a module, 2–12
creating new signals, 1–1
deleting, 2–18
replacing, 2–15
saving to disk, 2–13
Slot number, 2–10
TG 2000 Signal Generation Platform Service Manual
Specifications, 1–3
Standard accessories, 1–2, 10–16
Status bar, 2–10
Status of instrument, 2–7
Supported file types, 2–13
Switch setting, CPU configuration, 2–3
System clock specifications, 1–5
System control, 3–1
System delay, 3–5
System Function buttons, 2–6
System reference delay, 3–6
T
Temperature, operating/nonoperating, 1–3
Test signal hierarchy, 2–12
Test signals, 2–12
Theory of operation, 3–1
Timing delay, 3–6
Timing references, 3–4
Touch screen, 2–10
Troubleshooting, 6–37
flowcharts, 6–41
U
Using the disk drive, 2–13
Utilities button, 2–7
W
Weight of product, 1–3
Window title, 2–10
Index–3
Index
Index–4
TG 2000 Signal Generation Platform Service Manual

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project