YELLOW JACKET®

Add to my manuals
116 Pages

advertisement

YELLOW JACKET® | Manualzz
YELLOW JACKET
®
HVAC/R Service Tools
E D I T I O N
F I F T Y
Preferred
by leading
commercial
and residential HVAC/R
trade professionals
worldwide
S I X
YELLOW JACKET%
HVAC/R and Automotive Service Tools
P
PA
AG
GE
E
YELLOW JACKET
Recovery Machines
5
P
PA
AG
GE
E
YELLOW JACKET
SUPEREVAC™™ Systems
P
PA
AG
GE
E
YELLOW JACKET
Charging Systems
39
13
YELLOW JACKET
System Tools
97
YELLOW JACKET
Vacuum and
Charging Hoses
P
PA
AG
GE
E
YELLOW JACKET
Specialized and
General Use Gauges
59
Serving
the industry
since 1949
P
PA
AG
GE
E
P
PA
AG
GE
E
23
P
PA
AG
GE
E
YELLOW JACKET
Hose Adapters,
Valves, and Parts
P
PA
AG
GE
E
YELLOW JACKET
Electronic
Instruments
67
At Ritchie Engineering
Company, office personnel,
engineers, assembly staff,
quality control team, the
shipping department and the
sales professionals are
expected to share the
management philosophy
established in 1949.
It's a philosophy simply
stated in the company's
business mission –
33
P
PA
AG
GE
E
YELLOW JACKET
Leak Monitors and
Portable Detectors
83
Give AC&R professionals
the quality products they
need at a competitive
price in the necessary
time; and with
dependable
follow-through.
REFRIGERANT
RECOVERY
MACHINES
Pages 5-12
SuperEvac™
SYSTEMS
Pages 13-22
SuperEvac™ pumps . . . . . . . . . . . .14-18
Vacuum pump oil . . . . . . . . . . . . . . . .18
Evacuation products & hoses . . . .18-20
Belt drive pumps . . . . . . . . . . . . . . . . .19
Heat gun . . . . . . . . . . . . . . . . . . . . . . .19
Vacuum gauges . . . . . . . . . . . . . . .21-22
Pages 23-32
25
HOSE ADAPTERS,
VALVES AND PARTS
34
35
35-36
37
37
38
Pages 59-66
Manifold gauges °F
Liquid filled gauges °F
General use gauges
Contractor gauges
Diaphragm gauges
Vacuum gauges
Ammonia gauges
Manifold gauges °C
Electronic leak detector
Fluorescent leak scanners
System injectors
Scanner and dye solutions
Refrigerant leak monitors
Ammonia leak monitors
Hydrocarbon leak monitors
84-85, 91
86-90
86, 88
88-90
92-94
92-94
94
SYSTEM TOOLS
60-62
62
63
63
63
64
64
65-66
ELECTRONIC
INSTRUMENTS
Pages 67-82
Refrigerant leak detector
Combustible gas detector
Electronic charging scales
Refrigerant gas analyzer
Electronic vacuum gauges
Thermometers
Hygro-thermometer
Tachometer
Sound level meter
Anemometers
Psychrometer
Manometers – electronic
Gas pressure test kits
Pages 83-96
68-69
79
70-71
71
72-73
74-76
77
77
77
78
79-80
80
80
Pages 97-106
Cutters
Reaming & deburring
Cutter maintenance parts
Flaring
Swaging
Expanders
Fin combs and straighteners
Retaining ring pliers
Benders
Service wrenches
Hex wrenches
Pipe wrenches
Refrigerant recovery plier
Hex keys
Fan blade puller
Inspection mirrors
Valve core tool
Safety goggles
Can Taps
Refractometer
Oil pumps and injectors
98-101
100
101
102-105
104-105
105
106
106
107
108
109
109
109
110
110
111
111
111
111
111
112
LEAK MONITORS
AND DETECTORS
Pages 33-38
Control valve selection
Valve core tool
Quick coupler & SealRight
selection
Hose maintenance parts
Charging and intake adapters
Automotive fittings & adapters
SPECIALIZED
AND GENERAL
USE GAUGES
LEAK MONITORS
AND PORTABLE
DETECTORS
ELECTRONIC
INSTRUMENTS
26-27
28-30
28
30
30
31
32
32
42, 53
43
44-45
46, 49-50
47-48
51, 58
51, 58
51
54
55-56
57
GAUGES
1/4" original charging hoses
1/4" PLUS II ™ Hoses,
FlexFlow™, SealRight™
Heavy duty
Automotive manifold hose
Fuel oil assemblies
Ammonia hose
Stainless steel assemblies
Oil pressure control
PTFE assemblies
Digital refrigeration
system analyzer
BRUTE II manifolds °F
TITAN manifolds °F
All manifold repair parts
Series 41 manifolds °F
R-134a auto manifolds
Ammonia manifold
Single gauge manifolds
BRUTE II manifolds °C
TITAN manifolds °C
Series 41 manifolds °C
CHARGING
SYSTEMS
VACUUM AND
CHARGING
HOSES
Pages 39-58
VACUUM AND
HOSE ADAPTERS,
CHARGING HOSES VALVES AND PARTS
Recovery machines . . . . . . . . . . . . . .6-9
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Refrigerant recovery pliers . . . . . . . . . .9
Recovery cylinders . . . . . . . . . . . . . . .10
Comparison chart . . . . . . . . . . . . . . . .10
Trap separator . . . . . . . . . . . . . . . . . . .10
Automotive refrigerant
recovery systems . . . . . . . . . . . . . . .11
81
81
81
81
82
SUPEREVAC
SYSTEMS
Inspection mirrors
Oil pump vibration eliminator
Fuel oil test kit
Gas test gauges
Test lead sets
CHARGING
SYSTEMS
RECOVERY
MACHINES
TABLE OF CONTENTS
YELLOW JACKET is a registered trademark of Ritchie Engineering Company, Inc.
NEW PRODUCT REVIEW – page 4
3
SYSTEM
TOOLS
PRODUCT NUMBER INDEX – pages 113-115
NEW PRODUCT REVIEW
YELLOW JACKET %
SUPEREVAC™ Systems
YELLOW JACKET % System Tools
DIGITAL VACUUM
GAUGE
page 21
VALVE CORE TOOL
page 111
YELLOW JACKET %
Recovery Systems
YELLOW JACKET %
Instruments
DIGITAL ELECTRONIC
MANOMETER
page 80
RecoverX REFRIGERANT
RECOVERY MACHINES
page 6
DIGITAL SLING
PSYCHROMETER
page 79
YELLOW JACKET % Gauges
YELLOW JACKET %
Test and Charging systems
REFRIGERATION SYSTEM
ANALYZER
page 42
4
TITAN 2- AND 4-VALVE
MANIFOLDS
pages 44-45
BRUTE II ™ TEST AND
CHARGING MANIFOLD
page 43
CERTIFIED AND 4" GAUGES
page 60
YELLOW JACKET Recovery Machines —
for every refrigerant,
every size system
NEW
RecoverX™ Family
of Refrigerant Recovery
Machines
5
YELLOW JACKET Refrigerant Recovery Machines –
the growing line for every size system
When you see the YELLOW JACKET®
name on a hose, you know you’ve
got the genuine item for industry
proven performance. Today, you’ll
also find the YELLOW JACKET name
on a line of refrigerant recovery
machines for the smallest appliance
to the largest system.
RecoverXL REFRIGERANT RECOVERY MACHINES –
fast recovery of most refrigerants including R-410A
All are backed by the experience
of having more units in the field
than the total of many different
competitive units combined.
Building block approach
to select a system for your needs
Make your selection based on
system size, your budget, and
performance features that build
through the line. On this page,
start with the high speed of the
RecoverXL. Add automatic
operation with the RecoverXLT
and then subcooling with the
RecoverXLS System.
RecoverXLT and RecoverXLS
include a 3-Year warranty on
compressor
Every unit is full-function tested
in the factory to help insure
trouble-free operation. Results and
a full 1-year warranty (3 year
compressor warranty on RecoverXLT
and RecoverXLS) are included
with each RecoverX model.
Call 1-800-769-8370 for technical
support for as long as you own the
equipment. Telephone calls typically
solve 90% of problems without
returns. Technical support is also
available in Europe. Replacement
parts are easy to install and readily
available through your YELLOW
JACKET wholesaler.
Since Federal laws prohibit
venting or blowing off a charge
during service, a recovery unit
is mandatory.
See page 10 for selection chart.
6
The YELLOW JACKET RecoverXL
Machine provides fast recovery of
Class III, IV, and V refrigerants
including R-410A. Features include
all of the following:
• Durability with proven 1/2 hp oil-less
direct drive compressor. Permanently
lubricated cylinder walls eliminate
oil maintenance and compatibility
problems
The weight of all units balance away
from the side of your leg for easier
carrying on a long walk to the back of
a house or a long climb to a roof top.
• Easy, intuitive use with single-valve
set-up and no hose switching
(patent pending)
• Built-in mesh particulate filter
to protect unit from dirty systems
• “On-the-fly” purge with simple
turn of a knob to remove residual
refrigerant and help prevent cross
contamination
UPC#
Description
95740
95753
RecoverXL 115/60 Hz
RecoverXL 230/50 Hz (Euro plug)
Compressor
1/2 hp oil-less
1/2 hp oil-less
RECOVERY
MACHINES
RecoverXLT UNIVERSAL RECOVERY MACHINES –
adds fully automatic operation to the full features of RecoverXL
• Quiet running with components
nested to reduce vibration and noise.
Oil-less compressor is inherently
quiet. Tough HDPE case
dampens vibration rather than
amplify it like metal
• High volume air flow ducted over
large condenser for cool running
even in high ambient temperatures
• Controls and gauges inset for
protection and angled for easy access
and viewing
• High strength construction for
rugged use, yet lightweight at less
than 33 pounds. (14.78 kg). Rounded
corners help protect you and your
customers property from scrapes
R-410A ready
color-coded gauges
(500 low side;
800 high side)
Reusable mesh
particulate filter
inserts into
suction port for
protection
Single valve
control for easy
changeover from
liquid to vapor to
purge (patent
pending)
Recovery
complete
indicator
95762 (Shown)
Circuit breaker
Start with the features of the RecoverX
and add fully automatic operation for
every refrigerant.
• Senses back pressure from tank
and shuts off automatically at 520 psi
for safety
• Single valve control for easy
changeover from liquid to vapor to
purge (patent pending)
• Single high pressure safety switch
• CPR valve regulates refrigerant to the
compressor. Eliminates the need for
the technician to throttle the suction
valve. Protects the life of your
compressor, and your investment
Convenient cord storage.
Constant pressure
regulator valve to
regulate refrigerant
input and protect
compressor life.
• Advanced 1/2 hp, 3425 rpm oil-less
compressor with precision valves
manufactured in an ISO-9001 facility
• Recovers refrigerant and shuts off
when unit reaches 15" of vacuum.
Unit will automatically restart if
system pressure rises
• Reusable mesh particulate
filter inserts into suction port for
protection. Simple cleaning
eliminates replacement due to
clogging
• Color-coded hook-ups for proper use
• “On-the-fly” purge with simple turn
of a knob to remove residual
refrigerant and help prevent cross
contamination
• Designed and manufactured in USA
• Tested by UL to ARI 740-98
• LED signals recovery completion
• High efficiency fan keeps air moving
across condenser for cool
running even in hot weather
High efficiency fan keeps
air moving across the condenser for
cool running even in high temperature
operating conditions.
See refrigerant ratings chart for all machines
on page 10.
UPC#
Description
95760
95762
95763
95767
RecoverXLT 115/60 Hz
RecoverXLT with tank overfill switch 115/60 Hz
RecoverXLT 230/50 Hz (Euro plug)
RecoverXLT 230/50 Hz (UK plug)
Compressor
1/2 hp oil-less
1/2 hp oil-less
1/2 hp oil-less
1/2 hp oil-less
7
RecoverXLS UNIVERSAL RECOVERY MACHINES –
adds subcooling to the RecoverXLT
When ambient
temperatures
go up at a
service site,
refrigerant in
the recovery tank
gets hot and expands
to increase pressure, reducing
recovery speed. You could either ice
the tank to cool and condense the
contents or just flip the subcooling
switch on the new RecoverXLS
Machine. The switch is faster and
more convenient.Subcooling lowers
the temperature of refrigerant below
its dew point. In subcooling mode
the RecoverXLS draws hot vapor
from the recovery tank and it goes
back through the condenser. The
vapor is cooled and returned to the
tank as a liquid to lower tank temp
and pressure. With a cooler tank and
lower pressure, you can fill the tank
more quickly with more refrigerant
on hot days, and help maximize
compressor life.
ble
a
l
i
a
Av ring
in Sp 7
200
RecoverXLS to the system and tank.
Like the RecoverXLT recovery is
automatic. Simply connect the “vapor
out” from the recovery tank to the
subcooling port on the RecoverXLS.
No refrigerant will flow while the
subcooling switch is “Off.”
the recovery tank, circulated through
the RecoverXLS condenser, and then
returned to the recovery tank as
cooled liquid to lower both tank
temperature and pressure.
Simply flip the switch to the “Off”
position when the tank has cooled to
the desired level and continue the
recovery process as usual.
Turn the suction valve to the “Off”
position and the subcooling switch
“On.” Vapors will be collected from
Liquid (open)
To 110V
grounded
receptacle
Vapor (closed)
(unless in
subcool mode)
RECOVERY
TANK
Scale
Liquid service
port (liquid
recovery only)
HVAC unit
or appliance
To subcool port
Set-up is a simple 3-hose
hook-up when connecting the
Vapor service port
(liquid or vapor recovery)
RecoverX REFRIGERANT RECOVERY MACHINES – cost-effective
for smaller systems and push/pull liquid applications
Recovery Machine – over 50,000 sold.
New features include the following:
• Maximum air flow and cool running
even in high ambient temperatures.
High efficiency fan keeps air moving
across condenser
• High strength HDPE case for light
weight and rugged use. Rounded
corners help protect you and your
customers from nicks and scrapes
This economical recovery unit builds
on the performance and success of the
original YELLOW JACKET ® RecoverX
8
• Whisper-quiet 1/6 hp oil-filled
reciprocating hermetic compressor
UPC#
Description
95700
RecoverX 115/60 Hz
charged with polyol ester oil. Oil
drain port for easy maintenance
• Controls and gauges inset for
protection and angled for easy
access and viewing
• High pressure switch with automatic
reset and external circuit breaker
• Designed and manufactured in USA
See page 10 for performance and
selection chart.
Compressor
1/6 hp hermetic
RECOVERY
MACHINES
R 100 SERIES REFRIGERANT RECOVERY MACHINES –
the speed you need for larger commercial jobs
This is the high speed system for large
quantity refrigerant transfer, junkyard
transfer, supermarket rack systems, and
other larger commercial jobs.
• Fast twin cylinder 1 hp oil-less
compressor recovers direct liquid at
up to 5 lbs/min., or .6 lbs./min. vapor
per ARI 740-95
• High capacity 6" muffin fan and
oversized 3/8" slit fin condenser
with 3-pass path for cool running in
high ambient temperatures
• Tank overfill sensor
MESH PARTICULATE FILTER
• Built-in reusable mesh particulate
filter to protect from dirty systems
• “On-the-fly” purge with simple turn
of a knob to remove residual
refrigerant and help prevent cross
contamination
• Designed and manufactured in USA
See page 10 for performance and
selection chart.
UPC#
Description
95100
R 100 Refrigerant Recovery System 115/60 Hz
SIGHT GLASS
Compressor
1 hp oil-less dual cylinders
PARTS FOR RecoverX MACHINES
UPC# Description
Mesh particulate filter for YELLOW
JACKET® Recovery Machines remove
particles to protect units. Easy to clean
and reuse, or replace.
UPC# Description
95134
95136
95139
Screens R 50a, R 70a Series (4 pk)
Screens R 80a, R 100 Series (4 pk)
Screens R 60 and R 60a Series (4 pk)
95141
95457
Screens RST, R 50 (4 pk)
Replacement filter screen for
RecoverX family
RECOVERY BURNOUT FILTER
for dirty systems
High capacity inline filter drier removes
moisture and oil breakdown products, as
well as acid from burnt out systems.
Attaches directly to refrigerant recovery
system with a 1/4" female and a 1/4"
male connection. UL and CSA listed.
UPC #
Description
95014
Recovery filter(3 pack)
Use with YELLOW JACKET RecoverX and
RecoverXL machines. Indicates when all
liquid has been recovered so you can
switch immediately to vapor cycle and
speed-up the recovery process. 1/4" flare
x 1/4" female flare.
95156
95190
Circuit breaker - 12 AMP
Capacitor
95187
95188
Relay
Shorting cap for umbilical cord
95210
95215
95216
Large cord strain relief bushing
Power cord
Rocker switch
95218 Oil-less compressor 115V, 60 Hz
95248 Umbilical cord overfill sensor
95253
95291
95292
95293
Solid state board w/ remote LED's
Green LED light
Yellow LED light
Red LED light
UPC #
Description
95294 Fan clip
41125
Sight glass with 1/4" connections
95325
95338
95444
95445
95446
High pressure switch
Low pressure switch
Case, front
Case, rear
Case half (both halves)
95447
95448
95449
95450
95451
Case, cord wrap
Aluminum frame
Compressor bracket grommet
Condenser coil
High pressure gauge
MACHINE PARTS FOR R 50a,
R 60a, R 70a, R 100 (old machine)
UPC# Description
95121 Compressor kit for oil-less units
95122 Eccentric and bearing assembly
for R 60/R 60a, R 70a
95123 Compressor service kit for R 50/R 50a
95124 Compressor service kit for R 100
95125 Eccentric and bearing assembly
for R 50/R 50a, R 100
95126 Compressor overhaul kit for R 100
95148 Conversion for 3 pin Brad Harrison
to Thermoflo adapter
95150 TOS 80% overfill kit for R 50a
95188 Shorting cap
95230 Head and valve plate assembly
for oil-less machines
95287 Connecting rod for R 60/R 60a, R 70a
.750 stroke
95341 Connecting rod for R 50/R 50a, R 100
.600 stroke
95342 Repl. brass bulkhead fitting
for R 50a, R 60a, R 70a
95343 Repl. “O”-ring for R 50a, R 60a, R 70a (3-pk)
95452 Low pressure gauge
95453 Manifold assembly
95454 CPR valve
95455 Fan blade
95456 Neon lamp
95457 Replacement filter screen
REFRIGERANT RECOVERY PLIERS
See Page 109.
9
RECOVERY MACHINES AT A GLANCE
TÜV
Domestic
RecoverX #95700
RecoverXL #95740
RecoverXLT #95760
Recovery capabilities
Compressor
Weight
Size LWH inches
Size LWH mm.
Refrigerant
Compatibility
Vapor and push/pull
1/6 hp oil filled hermetic
29.0 lbs. (13.15 kg)
19.3 x 12.4 x 12.5
490 x 315 x 317
12, 22, 134a, 407C, 500,
502, HP, MP, blends
Vapor, liquid, push/pull
1/2 hp oil-less
31.0 lbs (14.07 kg)
19.3 x 12.4 x 12.5
490 x 315 x 317
12, 22, 134a, 500,
502, HP, MP, blends
Vapor, liquid, push/pull
1/2 hp oil-less
32.6 lbs. (14.78 kg)
19.3 x 12.4 x 12.5
490 x 315 x 317
12, 22, 134a, 500, 407C,
410A, 502, HP, MP,
blends
Vapor, liquid, push/pull
1 hp oil-less twin cylinder
48 lbs. (21.8 kg)
14.7 x 12.1 x 12.7
373 x 308 x 348
12, 22, 134a, 500, 502,
HP, MP, blends and 407C,
410A and 407C,410A
R100 #95100
Volts/hertz
Tank over-fill sensor
Low pressure
shut-off sensor
Inlet mesh filter screen
Inlet filter dryer
Suction and
pressure gauges
Upgraded higher
pressure gauges
Suction and pressure
Upgraded single higher
pressure switch
External circuit breaker
Warranty
115V/60 Hz
No
115V/60 Hz or 230/50 Hz
No
115V/60 Hz or 230/50 Hz
Standard on 95762
115V/60 Hz
Standard
No
No
Standard
Standard
No
Included
Included
Included
Optional Filter available for use on contaminated and burn-out systems, use a filter of adequate size. See page 9.
Standard
Standard
Standard
Standard
No
Standard
Standard
No
No
Standard
Standard
No
Standard
1 year parts and labor
Standard
1 year parts and labor
Standard
1 year parts and labor
Certified to ARI standard
Testing agency
CUL listed
ARI 740-95
UL
Yes
ARI 740-98
UL
Yes
Standard
1 year parts and labor;
3 years compressor
ARI 740-98
UL
Yes
ARI 740-98
UL
No
Recovery ratings
per ARI in lbs./min.
740-95
740-98
740-98
740-98
R-12
R-22
R-134a
R-407
R-410A
R-500
R-502
ARI ratingsstated in. kg./hr.*
R-12
R-22
R-134a
R-407
R-410A
R-500
R-502
Vapor
0.24
0.29
0.20
N/A
N/A
0.24
0.24
Vapor
6.60
7.80
5.40
N/A
N/A
6.60
6.60
Push/Pull
10.43
8.77
9.33
N/A
N/A
9.66
7.61
Push/Pull
283.80
238.80
253.80
N/A
N/A
262.80
207.00
Liquid
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Liquid
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Vapor
0 .31
0 .31
0 .31
0 .95
0 .42
0 .31
0 .55
Vapor
8.40
8.40
8.40
25.80
11.40
8.40
15.00
Push/Pull
13.12
13.12
13.12
11.88
11.60
13.12
13.18
Push/Pull
357.00
357.00
357.00
323.40
315.60
357.00
358.80
Liquid
1.68
1.68
1.68
1.65
1.68
1.68
2.29
Liquid
45.60
45.60
45.60
45.00
45.60
45.60
62.40
Vapor
0.37
0.37
0.37
N/A
0.42
0.37
0.66
Vapor
10.20
10.20
10.20
N/A
11.40
10.20
18.00
Push/Pull
12.81
12.81
12.81
N/A
11.60
12.81
12.90
Push/Pull
348.60
348.60
348.60
N/A
315.60
348.60
351.00
Liquid
1.98
1.98
1.98
N/A
1.68
1.98
2.65
Liquid
54.00
54.00
54.00
N/A
45.60
54.00
72.00
Vapor
0.37
0.44
0.31
N/A
N/A
0.37
0.60
Vapor
0.17
0.20
0.14
N/A
N/A
0.17
0.27
Push/Pull
14.09
16.87
15.04
N/A
N/A
14.93
16.76
Push/Pull
6.39
7.65
6.82
N/A
N/A
6.77
7.60
Liquid
3.70
3.70
3.51
N/A
N/A
3.68
5.16
Liquid
1.68
1.68
1.59
N/A
N/A
1.67
2.34
* ARI tests are only one way to evaluate recovery speed. In other testing conditions the units can exhibit much higher performance rates. ARI
rates are a "level field" comparison method. Performance test results for all units can be found at www.ari.org/directories/rrre/rrre-directory.pdf
REFRIGERANT RECOVERY CYLINDERS
These gray/yellow
30 and 50 lb.
cylinders
feature “Y” valve
for liquid/vapor,
400 psi rating,
and 3/4" plug
for a float switch.
UPC #
95002
95007
95012
95013
95008
95009
95010
95011
10
Description
30 lb. R-410A cylinder 400 psi
50 lb. R-410A cylinder 400 psi
30 lb. R-410A cylinder 400 psi
with float switch
50 lb. R-410A cylinder 400 psi
with float switch
“Y” valve for 30 lb. cylinder
Liquid level switch for 30 and 50 lb.
Worthington and Manchester cylinders
only with 3-pin Brad Harrison connection
Liquid level switch for 30 and 50 lb.
Amtrol cylinders only with 3-pin
Brad Harrison connection
“Y” valve for 50 lb. cylinder
THE TRAP SEPARATOR
High porosity filter
effectively traps sealant,
dye, and lubricant so only
pure refrigerant exits to
your recovery equipment.
Filter replacement is easy
in less than five minutes.
UPC #
Description
38087
The Trap Separator – 1/4” flare fittings
38081
Replacement Filter Pak
Series 800
machines are
the simplest,
easiest-to-use
A/C service
centers helping
technicians
meet today’s
tough service
standards.
Operation is
quick and efficient, lowering A/C
service costs.
The RMS 39800 Automatic and 39830
Automatic Plus provide full cycle
recovery/recycle/evacuate/recharge to
bring the vehicle back to factory spec
with the press of one button. Both
units offer:
• Oil injection
• 50 pound storage tank
The “Plus” in the 39830 refers to the
OEM-approved oil flush cycle that
circulates refrigerant, removing oil
for fast retrofits.
Choose the RMS 39810 (R-12) or
RMS 39820 (R-134a) for the most
economical automatic recovery/recycle
solution. With these easy-to-use
machines, just connect the quick-connect
couplings to the vehicle and push the
Recovery Recycle switch to complete
the process. There are no confusing
valves to remember to open or
close. Rotate the vacuum timer to
the vacuum time you select and the
UPC#
optional YELLOW JACKET two-stage
vacuum pump provides a deep vacuum.
Scroll up the correct charge on the
high visibility LCD and push the
charge switch to quickly charge
refrigerant.
Additional RMS 810/820 features:
• Automatic tank full and high
pressure shut-offs
• 1/2 hp oil-filled hermetic compressor
• Advanced shock-resistant scale
• One touch Oil Injection
• One touch Oil Drain
• One touch Air Purge
Description
39800 Fully automatic recover/recycle/evacuate/recharge/w/ 6 cfm vacuum pump 115V/60 Hz
39810 R-12 recover/recycle/recharge w/ 4 cfm vacuum pump 115V/60 Hz
39811 R-12 recover/recycle/recharge without vacuum pump 115V/60 Hz
• Fast vacuum and powered charging
• Built-in self diagnostics
39820 R-134a recover/recycle/recharge w/ 4 cfm vacuum pump 115V/60 Hz
39821 R-134a recover/recycle/recharge without vacuum pump 115V/60 Hz
39822 R-134a recover/recycle/recharge w/ 6 cfm vacuum pump 115V/60 Hz
• Fully automatic air purging which
constantly monitors and purges
non-condensables
39830 Fully automatic “plus” recover/recycle/flush/evacuate/recharge/w/ 6 cfm vacuum pump 115V/60 Hz
39831 39830 with refrigerant identifier
39832 39830 with printer
39833 39830 with refrigerant identifier and printer
• Automatic shut-off
• Free training, set up, and lifetime
technical support
39870 Fully automatic dual unit for R-12 and R-134a
38079 Protective cover for 39830
39052 Protective cover for 39870
Frequently Asked Questions
1. For what refrigerants are
RecoverX family of Refrigerant
Recovery Machines?
They are tested by UL to ARI 740-98
(740-95 for 95700) and approved for
medium pressure refrigerants R-12,
R-134a, R-401C, R-406A, R-500:
medium high pressure refrigerants
R-401A, R-409A, R-401B, R-412A,
R-411A, R-407D, R-22, R-411B, R-502,
R-407C, R-402B, R-408A, R-509; and
high pressure refrigerants R-407A,
R-404A, R-402A, R-507, R-407B,
R-410A (RecoverXL and RecoverXLT).
2. Is ARI the only testing agency?
No. ARI is only a certifying agency
that hires another agency to perform
the actual testing. UL is also EPA
approved as a testing and certifying
agency. YELLOW JACKET Machines are
UL tested for performance. Some
YELLOW JACKET Machines are tested to
CSA, CUL, CE, and TÜV safety
standards which go beyond the ARI
performance standards.
3. Can I compare machines by
comparing their ARI or UL ratings?
Yes. ARI and UL test standards should
be the same. And remember that
manufacturers can change the conditions
under which they test their own
machines to give the appearance of
enhanced performance. Only ARI and
UL test results provide consistent
benchmarks and controls on which to
make objective comparisons.
4. How dependable are YELLOW JACKET
Refrigerant Recovery Machines?
YELLOW JACKET equipment has been
tested at thousands of cycles, and are
backed with the experience of units in
the field since 1992.
5. Is pumping liquid the fastest
way to move refrigerant?
Yes, and the RecoverX, RecoverXL,
RecoverXLT, RecoverXLS, and R 100
monitor liquid flow at a rate safe for the
compressor. In YELLOW JACKET lab
testing, over 80,000 pounds of
(Continued on next page.)
11
RECOVERY
MACHINES
AUTOMOTIVE REFRIGERANT MANAGEMENT MACHINES (RMS) SERIES 800
Frequently Asked Questions (continued)
liquid R-22 were continuously and
successfully pumped. That’s the
equivalent of refrigerant in over 25,000
typical central AC systems.
all residual refrigerant is purged into the
recovery tank and you’re finished. Purging
is completed without switching off the
recovery unit.
A) High volume air flow through a
large condenser to keep the unit
running cooler and help eliminate
cut-outs in high ambient temperatures.
6. What is the push/pull recovery method?
9. Can increased airflow benefit
recovery cylinder pressure?
Many technicians use this recovery
method, particularly on large jobs. By
switching the RecoverX, RecoverXL,
RecoverXLT, RecoverXLS, or R 100
discharge valve to “purge” during
push/pull recovery, the condenser is
by-passed, increasing the “push”
pressure and speeding the recovery.
B) Single automatic internal high
pressure switch for simple operation.
Yes. For reliable performance in high
ambient temperatures, YELLOW JACKET
units are engineered with a larger
condenser and more aggressive fan blade
with a greater pitch. This allows the unit
to run cooler and keeps the refrigerant
cooler in the recovery cylinder.
C) CPR valve rated to 600 psi for safety
and it eliminates the need to monitor
and regulate the unit during
recovery.
7. Why do the RecoverX through R 100
feature a built-in filter?
10. Can I service a YELLOW JACKET System
in the field?
Every recovery machine requires an
in-line filter to protect the machine
against the particles and “gunk” that can
be found in failed refrigeration systems.
For your convenience, the RecoverX,
RecoverXL, RecoverXLT, RecoverXLS,
and R 100 Series incorporate a built-in
100-mesh filter that you can clean, and if
necessary, replace. The filter traps 150
micron particles and protects against the
dirtiest systems to maximize service life.
In case of a burn-out, an acid core
filter/drier is mandatory. The YELLOW
JACKET filter is built-in to prevent
breaking off like some competitive units
with external filters. See page 9.
Although YELLOW JACKET Machines
feature a full one year warranty, there
are times when a unit will need a
tune-up. The service manual with
every unit includes a wide variety of
information such as tips to speed
recovery, troubleshooting guides, and
parts listings. On the side of every unit,
you’ll find hook-up instructions, a
quick start guide, and simple tips for
troubleshooting. And if ever in doubt,
just call 1-800-769-8370 and ask for
customer service.
8. What is auto purge
and how does it work?
11. Are there any recovery machines
certified for R-410A?
At the end of each cycle, several ounces
of refrigerant can be left in the recovery
machine to possibly contaminate the
next job, or be illegally vented. Many
competitive recovery machines require
switching hoses, tuning the unit off and
on, or other time-consuming procedures.
The RecoverX, RecoverXL, RecoverXLT,
RecoverXLS, and R 100 can be quickly
purged “on the fly” with a simple turn of
the single control valve. In a few seconds,
The YELLOW JACKET RecoverXL,
(95753 and 95756), RecoverXLT, and
RecoverXLS series have also been UL
tested and certified for high-pressure
gases such as R-410A that are covered
under ARI 740-98.
All service and repair parts are readily
available through your nearest YELLOW
JACKET wholesaler.
12. What features should I demand
in a system to be used for R-410A?
Look for the following three features as
a minimum:
Additional Information For additional questions and answers or more
information, please contact the factory at the address on the back cover or
visit our website at: www.yellowjacket.com
12
13. What is a CPR valve?
The CPR (Constant Pressure Regulator)
valve is the feature that makes the YELLOW
JACKET RecoverXLT and RecoverXLS
the first truly automatic recovery
machines for every refrigerant. The
600 psi rated high pressure switch covers
all refrigerants and eliminates the need for
a control panel with two selector switches,
one for R-410A and a second for medium
pressure.
The CPR valve automatically reduces
the pressure of the refrigerant being
recovered. Regardless of which
refrigerant, input is automatically
regulated through a small orifice that
allows refrigerant to flash into vapor for
compression without slugging the
compressor. Throttling is not required.
Under normal conditions, you could
turn the single control valve to the
“liquid” or “vapor” setting. The machine
will complete the job while you work
elsewhere.
14. With the YELLOW JACKET RecoverXLT
design, do I have to manually reset
a pressure switch between medium
and high pressure gasses?
No. Some competitive machines require
you to choose between medium and
high pressure gas settings before recovery.
You’ll see the switch on their control
panels. With the YELLOW JACKET
RecoverXLT, the single internal
automatic high pressure switch makes
the choice for you. That’s why only
RecoverXLT is truly automatic.
YELLOW JACKET SUPEREVAC ™™ Systems –
faster calls,
fewer call backs
NEW
NEW
Vacuum Pump page 16
Manufactured in U.S.A.
Digital Vacuum Gauge
page 21
13
YELLOW JACKET SUPEREVAC ™ Systems Approach –
protect your profits, reputation and customer's system
Competition, increasing refrigerant
cost and legislation, higher customer
expectations...all that and more
combine to squeeze your profits.
Page 29
Systems-matched
for fast, high
evacuation.
Plus, three more situations are now
pressuring you to reconsider how to
evacuate systems.
• Today's higher efficiency systems
are more sensitive to damage
from contaminants.
Page 20
• Newer oils require deeper vacuum
for contaminant removal.
• Triple evacuation and purging are
considered venting.
With so many challenges to the
success of your business, it's simply
not enough to work hard. It's also a
matter of working smarter by taking
advantage of every advanced technology
such as the SuperEvac™ System, that
offer service techniques like fast, low
vacuum.
The SuperEvac System pulls a fast
vacuum to 15 microns and better. Fast
gives you more time for more calls.
And 15 microns and better is deep
enough to get rid of contaminants that
could cause system failure, customer
dissatisfaction, and no-charge rework.
The heart of the system is the new,
improved YELLOW JACKET pump.
But not even the best pump can give
Page 16
Page 21
you the most cost effective
and efficient evacuation
unless properly used.
Proper use begins
with the systems
approach with pump,
manifold, hoses, valves,
and more – all engineered
and matched for
fast, unrestricted
evacuation.
SuperEvac
System
Hook-up
Pump Design Details Matter
Attention to details makes a
YELLOW JACKET Vacuum Pump your
best long term investment:
• Internal check valve to prevent oil
from backing up into the system
during a power failure.
• Large intake fitting to maximize
flow and decrease vacuum time.
• Hardened drive shaft and large
bearing contact areas extends pump
service life.
• Filter screen keeps large particles
from entering the pump mechanism.
• Isolation valve to allow oil change
during lengthy evacuations without
losing vacuum.
14
• Precisely machined and fitted parts
assembled with running clearances
of less than .001" to generate a
deep vacuum.
• Specially designed high-torque
motor for starting when the pump
is cold, or when an extension cord
is used.
As the only manufacturer that
completely tests and runs in every
pump, Ritchie Engineering ships
with the confidence that each pump
will meet your expectations.
How and why one small drop dampens your profits.
During new system set-up, all
protective caps are removed allowing
moisture and air into the system
components.
If air – a non-condensible – remains
in the system, it collects on the high
side reducing system efficiency. This
causes a rise in head pressure. The
discharge valve gets hotter than normal
and organic solids form causing
compressor failure.
Moisture in the system can form ice
which closes off openings in expansion
valves and cap tubes, and prevents
adequate cooling.
Ultimately moisture and air combined
with refrigerants containing chlorine
can produce acids and sludge which
could cause in-warranty failures.
During service and parts replacement,
the same contaminants get in again,
and you could be called back for
repairs by a dissatisfied customer.
Moisture and air can even enter
through system leaks. And as the
moisture in the air increases, so does
the amount of contamination. The
higher the humidity, the bigger your
problem.
A vacuum pump "pulls" air and
moisture out of the system before the
system is damaged. The deeper and
more complete the vacuum, the more
moisture is removed. That's why the
SuperEvac™ pump is specifically
engineered for deep vacuums of 15
microns and better.
SUPEREVAC
SYSTEMS
A drop of moisture can
hurt your profits and
reputation. And with
the increased moisture
sensitivity of modern
A/C and refrigeration
systems, proper evacuation is essential.
Most system complaints can be attributed to moisture. Here’s how and why.
What is a micron as a unit
of measurement for a vacuum?
When referring to microns as a
unit of measurement for vacuum, the
reference is to microns of mercury in
the same way as you would refer to
atmospheric pressure in inches of
mercury on a barometer. One inch Hg
is about 25,000 microns.
To help clarify terminology, remember
that the deeper the vacuum, the more
complete the vacuum; and the more
complete the vacuum, the lower the
number of microns.
Refer to www.yellowjacket.com for
other technical articles.
Frequently Asked Questions
1. How can I select the right pump cfm?
The following guidelines are for
domestic through commercial
applications.
System size (tons)
1-10
10-15
15-30
30-45
45-60
60 and above
3. Do I connect an electronic vacuum
gauge to the system or pump?
To monitor evacuation progress,
connect it to the system with a
vacuum/charge valve (see page 20).
Pump cfm
1.5
2.0
4.0
6.0
8.0
11.0
2. How much of a vacuum should I pull?
A properly evacuated system is
at 2500 microns or less. This is
1/10 of one inch and impossible to
detect without an electronic vacuum
gauge (see pages 21-22). For most
refrigeration systems, ASHRAE
recommends pulling vacuum to
1000 microns or less. Most system
manufacturers recommend pulling
to an even lower number of microns
between 300 and 500.
4. Why does the gauge micron reading
rise after the system is isolated from
the vacuum pump?
This indicates that water molecules
are still detaching from the system
interior surfaces. The rate of rise
indicates the level of system
contamination and if evacuation
should continue.
5. Does extension cord length affect
performance?
Increased length can decrease
voltage, so use this as a voltage
guide for selecting wire gauge.
Distance
Wire Gauge
25'
50'
100'
16
14
12
6. How can I speed evacuation?
A. Use clean vacuum pump oil (see
page 18). Milky oil is water saturated
and limits pump efficiency.
B. Remove valve cores from both
high and low fittings with a vacuum/
charge valve tool (see page 20) to
reduce time through this orifice by
at least 20%.
C. Evacuate both high and low sides
at the same time. Use short, 3/8"
diameter and larger hoses.
D. SuperEvac Systems (see page 20)
can reduce evacuation time by
over 50-60%. SuperEvac pumps
are rated at 15 microns (or less) to
pull a vacuum quickly.
E. Use a heat gun (see page 19).
15
YELLOW JACKET 4, 6, 8, and 11 CFM SUPEREVAC™ VACUUM PUMPS –
designed inside and out for reliable performance day after day
FULL QUALITY CHECK
Each YELLOW JACKET pump is
thoroughly “run in” and tested to
insure that it meets or exceeds our
quality specifications – and our
customers’ expectations.
Heavy-duty steel handle with lift hook
for well-balanced carrying.
Isolation valve with vented
ball for oil changes without
losing vacuum in the
system.
Tethered port caps stay
with the pump.
Wide-mouth oil reservoir
port for easier, neater
filling. Doubles as pump
exhaust. Threaded to
attach garden type hose
for exhausting to remote
location.
E
USIV
L
C
X
E Built-in vacuum indicator
gauge –
Every YELLOW JACKET pump
features an exclusive built-in
indicator gauge to monitor the
evacuation progress down to the
green (29"-30") range. If the
reading stays in the mid range, there
is either high contamination or a
large leak in the system.
If you think there is
excessive moisture,
blow out the AC&R
system with dry
nitrogen before
Gross leak
connecting the vacuum
pump to the system wherever
possible. This reduces the amount of
contaminants that must be "pulled"
into the pump and increases
evacuation speed.
Use a nitrogen regulator
valve with pressure
limited to 150 psi,
and a frangible disc
device set at 175 psig.
When the indicator
Turn on
electronic
reaches the green
gauge.
(29"-30") range, the
electronic micron gauge
must be used for more
precise readings. See pages 21-22.
Exclusive built-in
vacuum indicator
gauge.
Metal with rubber
overlay base for
stability.
Large brass oil drain fitting
with easy access for fast,
clean oil changes.
INSIDE
OILING SYSTEM
• Internal intake check valve
prevents oil back-up into the system
during a power failure.
• Large oil reservoir helps reduce
operating temperature and dilute
corrosive contaminants.
• Precisely machined and
assembled parts with tight clearances
for a deep vacuum.
• Gas ballast valve keeps oil cleaner,
longer during evacuation of wet
systems.
• Hardened cap screws keep the
pumping mechanism tight.
• YELLOW JACKET mineral-based
vacuum pump oil is recommended
whether working with traditional or
new alternative refrigerants,
regardless of the oil used in the
system.
OUTSIDE
• Rugged metal construction for
long-lasting durability in the field,
with no flimsy plastic parts that are
easily damaged.
• Updated, lighter housing with
larger fins for cooler running.
16
Large oil sight
glass for easy
monitoring of
the oil level.
Anti-suck back
in case of power
failure.
For increased efficiency, the first
stage exhausts into the second
stage similar to using two single
stage pumps connected together.
●
●
●
●
●
SUPEREVAC
SYSTEMS
3/8" and 1/4" pump intake
fittings for maximum flow
with attached hoses or a
SuperEvac® evacuation
manifold.
Intake filter screen
to keep damaging
particles from
entering the pump.
Pump and first stage intake
First stage compression
Second stage intake
Second stage compression
Exhaust to atmosphere
DRIVE TRAIN
• Heavy-duty, high torque 1/2 hp,
1725 rpm motor assures cold
weather starting.
• Advanced engineering for quieter
operation.
Heavy duty
rotors and
bearings.
Highly efficient 2-stage
rotary vane design
field-rated at 15 microns or
better. (Lower the micron
rating, the better the pump
performance.)
Hardened drive shaft with large bearing
contact areas provides long pump life.
YELLOW JACKET SuperEvac™ PUMP 1.5 CFM
A more compact 2-stage 1.5 cfm
vacuum pump for the smaller jobs
such as appliance and small residential.
Designed and built to the same
quality specifications as the larger
YELLOW JACKET pumps.
• Evacuate quickly to ultimate
vacuum of 15 microns.
• Heavy duty construction includes
all metal parts and a rugged 1/6 hp
motor. Capacitor start.
• Compact size for easy handling.
• Offset vanes maximize capacity.
• Fully tested, inspected and run-in.
• Supplied with 3/8", 1/4" flare and
1/2" Acme intake fittings
Complete specifications on page 18.
Heavy duty handle.
Anti-suck back
in case of power
failure.
Heavy duty cast body.
Large fitting for
easier oil filling.
Accommodates
oil exhaust filter
#93386 or garden
hose for exhaust.
Built in vacuum
indicator gauge –
see details
page 16.
Switch
on motor.
Large,
replaceable
sight glass.
Easy to
read.
Internal thermal
overload protector.
Heavy duty
rotors and
bearings.
Metal with rubber
overlay base for
stability.
Large oil drain.
Large oil capacity
to absorb moisture.
17
YELLOW JACKET SUPEREVAC PUMPS SPECIFICATIONS (4-11 CFM)
Domestic
Model 93540
Model 93560
Model 93580
Model 93590
Free air displacement
Number of stages
Field blankoff
Intake
Motor
4.0 cfm
2 stage rotary vane
15 microns
1/4" and 3/8" Male flare
1/2 hp - 1725 rpm
6.0 cfm
2 stage rotary vane
15 microns
1/4" and 3/8" Male flare
1/2 hp - 1725 rpm
8.0 cfm
2 stage rotary vane
15 microns
1/4" and 1/2" Male flare
1/2 hp - 1725 rpm
11.0 cfm
2 stage rotary vane
15 microns
1/4" and 1/2" Male flare
1/2 hp - 1725 rpm
Internal capacitor
thermal overload
Temperature rise 40° C
Temperature rise 40° C
Temperature rise 40° C
Temperature rise 40° C
Voltage (single phase)
Power cord
Oil capacity
Dimensions
115 Volt - 60 cycle
8' - motor mounted switch
36 oz.
15.25" L x 6.75" x 12" H
115 Volt - 60 cycle
8’ - motor mounted switch
34 oz.
16.25" L x 6.75" x 12" H
115 Volt - 60 cycle
8' - motor mounted switch
43 oz.
16.75" L x 6.75" x 12" H
115 Volt - 60 cycle
8' - motor mounted switch
39 oz.
16.75" L x 6.75" x 12" H
Net weight
29.5 lbs. (13.4 kg)
31.5 lbs. (14.3 kg)
34.0 lbs. (15.4 kg)
31.0 lbs. (14 kg)
Export
Export
Export
Export
Export
Model #
93542 (95 L/M at 50 Hz)
93562 (142 L/M at 50 Hz)
93582 (190 L/M at 50 Hz)
93592 (260 L/M at 50 Hz)
(113 L/M at 60 Hz)
(170 L/M at 60 Hz)
(225 L/M at 60 Hz)
(310 L/M at 60 Hz)
115/220V, 50/60 Hz
115/220V, 50/60 Hz
115/220V, 50/60 Hz
115/220V, 50/60 Hz
93563 (142 L/M at 50 Hz)
93583 (190 L/M at 50 Hz)
93593 (260 L/M at 50 Hz)
(113 L/M at 60 Hz)
(170 L/M at 60 Hz)
(225 L/M at 60 Hz)
(310 L/M at 60 Hz)
230V, 50 Hz
230V, 50 Hz
230V, 50 Hz
Voltage
Model #
93543 (95 L/M at 50 Hz)
Euro plug
Voltage
Model #
93547 (95 L/M at 50 Hz)
UK plug
(113 L/M at 60 Hz)
230V, 50 Hz
Voltage
Model #
93544 (95 L/M at 50 Hz)
(113 L/M at 60 Hz)
115/240V, 50/60 Hz
Voltage
230V, 50 Hz
93567 (142 L/M at 50 Hz)
93587 (190 L/M at 50 Hz)
93597 (260 L/M at 50 Hz)
(170 L/M at 60 Hz)
(225 L/M at 60 Hz)
(310 L/M at 60 Hz)
230V, 50 Hz
230V, 50 Hz
230V, 50 Hz
93564 (142 L/M at 50 Hz)
93584 (190 L/M at 50 Hz)
93595 (260 L/M at 50 Hz)
(170 L/M at 60 Hz)
115/240V, 50/60 Hz
(225 L/M at 60 Hz)
115/240V, 50/60 Hz
(310 L/M at 60 Hz)
115/240V, 50/60 Hz
Will not work with ammonia.
PUMP SPECIFICATIONS (1.5 CFM)
YELLOW JACKET VACUUM PUMP
OIL – now available in pints
YELLOW JACKET vacuum pump oil is
specially refined and formulated for
extremely low vapor pressure and high
pump efficiency at all temperature
conditions. This means that with proper
maintenance you will get a continued
return on your pump investment.
UPC #
93091
93092
93094
93095
Model 93350
Free air displacement
1.5 cfm
Number of stages
2 stage rotary vane
Field blankoff
Intake
15 microns
1/4" and 3/8" Male flares
and 1/2" Acme Male
1/6 hp 1725 rpm
Motor
Thermal overload
Temperature rise
40˚ C
Voltage
115 Volt - 60 cycle
Power cord
8' foot cord
Description
Oil capacity
16 oz.
Pint of vacuum oil - 24 per case
Quart of vacuum oil - 12 per case
Gallon of vacuum oil - 4 per case
55 gallon drum
Dimensions
10.5" L x 5.1" x 9.2" H
Net weight
20 lbs. (9.1 kg.)
3 sizes
MSDS sheet on website.
Use vacuum
sealant around
threads, through
flared connections,
face joints,
wherever metal
joins metal. Sets up quickly, and
Export
Export
Model
Voltage
93352
230V, 50 Hz
OIL EXHAUST FILTER
VACUUM FITTING SEALANT
18
Domestic
remains flexible for easy disconnection.
Seal to down to 1 micron. 4 ounce can
with brush applicator.
UPC#
Description
Screws onto the pump exhaust to
eliminate oil mist. Use on 1.5, 2,
4, 6, 8 cfm pumps as well as new
11 cfm pump.
Quantity
UPC#
Description
93090
Vacuum sealant
1 can
93386
Exhaust filter
93089
Vacuum sealant
12 /case
93387
Replacement element
YELLOW JACKET SUPEREVAC REPLACEMENT PARTS
OLD 1985-96
3, 5, 7.5
1.5
Original 1996-97 Updated 1998-2005 New 2005-present
4, 6, 8
4, 6, 8
4, 6, 8, 11
Large 1997-present
12, 18, 24
—
(Ritchie only
cast into cover)
(Label on
front cover)
—
(Ritchie cast
into cover)
Handle assembly
Oil fill cap with seal
Oil fill fitting
93042
93041
—
—
93390
93391
93401
93390
93391
93370
93390
93391
93370
93390
93391
93401
—
—
Oil sight glass
Oil drain plug
4 cfm cartridge complete**
6 cfm cartridge complete**
8 cfm cartridge complete**
11cfm cartridge complete**
93039
93040
—
—
—
93340
93368
—
—
—
93403
93402*
93441
93461
93481
93365
93368
93441
93461
93481
93365
93368
93441
93461
93481
93591
93812
93368
—
—
—
Shaft seal
30" vacuum gauge
Vacuum gauge lens
Gas ballast gasket with “O”-ring
O-ring for gas ballast
Intake port gasket
Toggle style switch
93031
93011
93012
93098
93032
93027
93114
93341
93011
93012
93368
93398
—
—
93031
93011
93012
—
93398
93393
93114
93031
93011
93012
93368
93398
93393
—
93031
93011
93012
93509
93398
93508
—
93798
93011
93012
93402
93032
93799
93807
Rocker style switch
Oil cover gasket
—
93048
—
93344
—
93404
93117
93369
93117
93507
—
93810
Drive coupling
Leg with screws
93047
93034
—
93034
93047
93034
93047
93034
93047
93034
93811
93797
SUPEREVAC MODEL#
Set of (4) replacement vanes
93420
93372
93440
93374
93460
93376
SUPEREVAC
SYSTEMS
(Ritchie & cfm
cast into cover)
93480
93378
* Discontinued **Complete cartridges with oil cover gasket. Completely assembled and pre-tested.
VACUUM PUMP
ADAPTER
HEAT GUN for faster vacuums
Convert
a 3/8" or
1/2" vacuum pump intake
into flare and Acme compatible fittings.
UPC # Description
36018
19015
36019
19011
1/2" pump adapter with 1/4" flare
and 1/2" Acme male fittings
1/2" replacement gaskets for 36018
3/8" pump adapter with 1/4" flare
and 1/2" Acme male fittings
3/8" replacement gaskets for 36019
600° and 1000°F settings. Shockproof
and tough housing is durable and
lightweight. Use for:
• Coil defrosting.
• Faster vacuums.
• Drying out condensation in
motors, clutches etc.
Kits include gun, adapters and case.
VACUUM PUMP
INTAKE REDUCER
ADAPTER
UPC# Description
19030
Rubber gasket “O”-ring (10 pak)
for 19130 and 19133
19130
3/8" Fe. fl. x 1/4" Male fl. adapter
19131
1/2" Fe. fl. x 3/8" Male fl. adapter
19132
1/2" Fe. fl. x 1/4" Male fl. adapter
19133
3/8" Fe. fl. x 1/2" Male fl. adapter
UPC#
Description
19160
1/2" Fe. fl. x 1/2" Male Acme adapter
69092
69093
Heat gun kit 115V - UL, CSA, CE
Heat gun kit 230V - Euro plug, CE
93058
Rubber gasket “O”-ring (1 pak)
for 19131, 19132 and 19160
BELT DRIVE VACUUM PUMPS (.88-17.7 cfm) by Hyvac Products
These
2-stage
pumps are
lab rated at
.1 micron
and feature
large oil capacity, vented exhaust,
standard belt guards, motor
capacitors and automatic overload
protection. Optional exhaust filters
available.
UPC#
80200
80210
80220
80230
80240
cfm - free air (L/M)
Ultimate vacuum (lab)
.88 (25)
.1 micron
2.79 (79)
.1 micron
5.6 (160)
.1 micron
10.6 (310)
.1 micron
17.7 (500)
.1 micron
Stages
Motor hp (ODP)
2
1/4
2
1/3
2
1/2
2
1
2
1-1/2
Voltage (single phase)
Pump rpm
Oil capacity
Gas ballast
Intake O.D.
115 - 60 Hz
580
1 quart
Standard
9/16"
115 - 60 Hz
525
1-1/2 quart
Standard
7/8"
115 - 60 Hz
525
5 quarts
Standard
1-1/4"
115 - 60 Hz
525
7 quarts
Standard
1-5/16"
115 - 60 Hz
550
9 quarts
Standard
1-13/16"
Dimensions L x W x H
Shipping weight
15" x 10" x 11"
70 lbs.
18" x 12" x 11"
110 lbs.
18" x 13" x 16"
135 lbs.
18" x 16" x 19"
154 lbs.
21" x 20" x 20"
242 lbs.
* For special electrical requirements, contact factory. Some 50 Hz available for export.
19
SUPEREVAC™ EVACUATION MANIFOLDS
vacuum time by over 50%
and improve micron readings.
Mounts with 1/2" or 3/8"
Female flare quick coupler
and provides easy connections
for two 3/8" vacuum hoses.
(see pages 28 and 29).
3/8" male flare x 1/4"
NPT Male fitting (41139)
1/4" Male flare
with Schrader
(40272)
1/4"
Male flare
(77921)
93850
93855
93860
1/2" Female flare coupler
93851
93852
93853
3/8" Female flare coupler
SuperEvac 1/2" manifolds are
engineered as system components for
the SuperEvac pumps to help decrease
UPC #
Description
93851
Single valve with 1/4" Schrader
mount with 3/8" Female flare
Single valve with low side gauge
mount with 3/8" Female flare
Two valves with low side gauge
mount with 3/8" Female flare
Single valve with 1/4" Schrader
mount with 1/2" Female flare
Single valve with low side gauge
mount with 1/2" Female flare
Two valves with low side gauge
mount with 1/2" Female flare
1/2" flare connector
1/4" flare x 1/8" NPT Male elbow
Replacement handle for all
3 ball valves
1/2" gasket (10-pak)
Pump step-down adapter.
3/8" Female flare x 1/2" Male flare
3/8" “O”-ring (10 pak)
3/8" flare cap with gasket
1/4" Male flare with Schrader
for 93850
3/8" Male flare x NPT Male fitting
Blue compound °F gauge
93852
93853
93850
93855
• Flutterless™ gauge
• Non-restricting, full flow
valves for fast vacuum
• Convenient 1/4 turn full
flow
• Extra port for electronic
gauge or charging cylinder
(41139)
• Now includes step down adapter to
connect to 3/8" pump intake
93860
93854
77921
19096
19015
19133
19030
93211
40272
41139
49002
SUPEREVAC EVACUATION SYSTEMS I, II & III
93865 System I
1/4" BALL VALVE
4-IN-1 VACUUM/CHARGE
VALVE & CORE TOOL
All system components are available
separately, but system pricing makes
I, II and III attractive buys.
System II adds 69075 electronic gauge
and service valve wrench to the basic
System I.
All systems include a 2-valve manifold
and two 3/8" vacuum hoses for a fast
vacuum. Vacuum valves,
UPC #
for 3/8"
included with all systems,
allow core removal and
93865
system isolation. This
93875
combination reduces vacuum
time by over 60% compared
93885
to using a regular 1/4"
manifold and evacuating
19030
through only one side.
System III adds a 6 cfm SuperEvac
pump to System II.
This versatile tool for the low or high
side of a system does four jobs:
18971
1. Vacuum valve. Extra 1/4" side
port on 18975 to attach electronic
micron vacuum gauge right at
system for greater accuracy.
2. Core removal access. Lets you
evacuate and charge through an
unrestricted line for increased
speed and higher vacuum.
18975
3. Core replacement.
UPC #
Description
18971
Vacuum /charge ball valve
18975
Vacuum/charge valve w/side port
20
4. Recovery valve. Core removal
speeds recovery process.
For more details see page 34.
Description
UPC #
for 1/2"
System I: 2-valve manifold, two
16248 48" vacuum hoses. 2 valves
System II: all of above plus
69075 electronic vacuum gauge
System III: all of above plus a
6 cfm SuperEvac pump (93560)
1/2" “O”-ring gasket (10 pak)
3/8" “O”-ring gasket (10 pak)
93866
93876
93886
(8 cfm)
19015
MECHANICAL VACUUM GAUGES
Mechanical vacuum gauges for system
installation. Bourdon tube type gauge.
All feature 1/8" NPT Male bottom
fitting. CAUTION: Handle
gauges carefully
to assure full
service life. See
page 64 for
further details.
UPC #
Description
69044
3 1/8" Vacuum gauge
0-30 inHg/760-0 Torr (mm)
3 1/8" Vacuum gauge
European version
(1000-0 millibar/30-0 inch)
69045
YELLOW JACKET DIGITAL VACUUM GAUGE with seven units of vacuum for confidence
• Displays 7 different units of vacuum
(microns, milliTorr, Torr, millimeters
of mercury, millibar, kiloPascal and
Pascal)
• Unique patented
thermal conductivity
sensor automatically
compensates for
temperature
• Replaceable,
cleanable, plug-in
sensor (Part #69087)
handles 450 psi
positive pressure
This easy-to-use gauge helps you to
be certain that air and moisture have
been removed from the system. Simple
push of a button changes the display
readout between 7 units of vacuum.
Each displays down to the equivalent
of 10 microns of vacuum to let you
know that your vacuum pump is clean
and performing properly. If the sensor
gets dirty, simply pull a new
sensor out of your tool kit, plug it
into the gauge, run
• 12" coiled sensor cord stretches to
24" for easy reach, connectivity, and
readability of display
• Low battery indicator
• Automatic shut-off after 20 minutes
• Operating Temperature Range:
32° to 122°F (0° to 50°C)
UPC #
Description
69086
Hand-held vacuum gauge with
fabric carry pouch
69087
69091
Replacement sensor
Replacement fabric pouch for 69086
• Weight: 12 oz. (340 g) with battery
• Calibration standards traceable to (NIST)
• Battery Life: Approximately
25 hours continuous use
YELLOW JACKET DIGITAL LCD ECONOMY VACUUM GAUGE
• Rugged contractor-grade
construction with tough ABS
housing and solid state circuitry
for accuracy
• Automatic battery saver shuts
gauge off after 20 minutes with
no reading changes
• Low battery indicator.
Versatile — Connect to the YELLOW JACKETN SuperEvac™ Vacuum
Pump, or in line with a tee fitting, or directly to the system with
YELLOW JACKETN core removal tool 18975 (at right and on page 34).
For peace of mind, this gauge shows
you that air and moisture have been
removed from the system. The lower
the number of microns, the more
complete the vacuum and less chance
for no-charge call-backs. Track down
14 increments from atmosphere to
25 microns to know that the system
is clean and your vacuum pump is
performing properly.
• Calibration standards traceable to
the National Institute of Standards
and Technology (NIST)
• Patented technology
Packaged complete with 9V alkaline
battery and hanging hook
• Unique thermal conductivity
sensor automatically compensates
for temperature with no calibration
UPC #
• Simple On/Off controls
69080
• Easy-to-clean sensor handles
450 psi positive pressure
69081
69079
Description
Digital LCD vacuum gauge with battery,
hook
Optional soft-sided protective case
Replacement battery door and screw
21
SUPEREVAC
SYSTEMS
through a quick
calibration process,
and be back on the job
within minutes
SuperEvac™ LCD VACUUM GAUGE –
Full range – atmosphere
to 1 micron
Compact design with storage
for sensor, cable and brass
connector.
YELLOW JACKET DELUXE LED
VACUUM GAUGE – AC powered
0.7" high
contrast digital
display for easy
reading.
5-1/2' coiled sensor cable
(straight cord with 69070)
Professional laboratory type instrument
with .56" high bright LED readout is
100% automatic.
Battery operated. Instant ON.
Advanced technology uses
only one "D" cell.
• Thermocouple sensor technology
for precise and repeatable accuracy
• Improved software expands
sensing range from atmospheric
pressure to 1 micron.
69073 sensor
Impact
resistant
housing.
Replaceable thermocouple
sensor with 1/4" flare adapter
requires no calibration.
YELLOW JACKET LCD vacuum gauges
combine thermocouple sensor
technology with advanced electronics
for precise readings and repeatability
not found with thermistor sensors or
analog meters. The result - accurate
readings from atmosphere to 1 micron
without recalibration on job after job.
Thermocouple technology has long
been proven in laboratory and precision
industrial instrumentation for sensing
the deep vacuum range. Thermocouple
sensors are factory calibrated and
exhibit few of the electronic variances
of thermistor sensors found in many
other electronic gauges.
Thermocouple sensor features:
• No adjustments or warm-up.
Stays calibrated after on/off
switching and long evacuations.
• Automatic battery compensation
• Automatic ambient temperature
compensation
LCD gauge features:
• Normal handling and jarring
will not affect the LCD reading
• Rugged molded case protects
electronic circuitry and sensor
• Calibration standards traceable
to (NIST)
22
• Calibration standards traceable
to (NIST)
69071 connector
• Precision circuitry controls
sensor and translates sensor
input into micron readings on
the easy-to-read LCD
Specifications
Response time:
Calibration:
Warm up:
Sensor cable:
Sensor
connection:
Operating
temperatures:
Power:
Battery life:
3 seconds
Automatic
3 seconds
5.5 feet (167 cm)
coiled
1/4" Male flare
32˚ to 120˚F
(0˚ to 49˚C)
1 "D" cell battery
70 hrs continuous
Battery check: On LCD display
Dimensions:
9" x 12.25" x 2.37"
(230 x 310 x 60 mm)
Accuracy:
± 20% of reading
UPC #
Description
69071
69073
Brass connector 1/4" FF x 1/4" FF
Replacement sensor
for 69070, 69075
SuperEvac LCD vacuum gauge
full range complete in case
(atmosphere to 1 micron)
Optional ball valve to add to sensor
1/8" NPT Female x 1/4" Female flare
69075
69067
19110
Optional coupler to add to sensor
1/8" NPT Female x 1/4" Female flare
Complete unit includes aluminum LED
display unit, sensor with valve, cable,
brass connector and carrying case.
Specifications
Response time:
Calibration:
Warm up:
Sensor cable:
Sensor
connection:
Operating
temperatures:
Storage
temperatures:
Power:
3 seconds
Automatic
3 seconds
9 feet (274 cm)
1/4" Male flare
with isolation valve
-30˚ to 150˚F
(-34˚ to 65˚C)
-30˚ to 160˚F
(-34˚ to 65˚C)
115V 60 Hz
(230V available)
Power cord:
6 foot
Dimensions:
4.25" x 5.5" x 1.5"
(108 x 140 x 38 mm)
Carrying case: Heavy duty plastic
12.25" x 8" x 3.5"
(310 x 203 x 89 mm)
UPC #
Description
69060
LED vacuum gauge kit
complete with case, 115V
LED vacuum gauge kit
complete with case, 230V
Sensor for 69060 and 69063
9' sensor cable for above
69063
69064
69065
69066
Carrying/storage case
69067
Ball valve for sensor
1/8" NPT Female x 1/4" Male flare
69071
1/4" Female flare connector
Optional vibration isolation hose
15006
YELLOW JACKET Vacuum and Charging
Hoses – industry
proven performance
Compact,
ergonomic ball valve
with zero restriction
for refrigerant flow.
Featuring PLUS II ™
Hoses with double
barrier construction
for the environment.
R-12
R-404A
R-409A
R-22
R-113
R-407C
R-410A
R-502
R-114
and
more
R-134a
R-123
Hoses for most
commonly used
refrigerants, plus
new refrigerants,
blends and
azeotropes.
R-507
R-11
ED
IMPROV
PLUS II ™ 3/4" Heavy Duty
Charging Hose page 30
UL recognized assemblies
Rated at 4000 psi burst,
800 psi working pressure
File SA9737
23
YELLOW JACKET HOSES – there's one for every job
with the name you know, the performance you want.
1/4" Flexible Hoses
3/8" Flexible Hoses
• Easily connects to 1/4" Male flare access fitting on system
1/2" and 5/8" Flexible Hoses
• Evacuates and charges 4 times
faster than 1/4" hose
• Evacuates and charges 8 times faster than
1/4" hose
• Allows you to pull a deeper vacuum
• More efficient job of removing moisture and
contaminants from the system
YELLOW JACKET Original
1/4" Charging Hose
YELLOW JACKET PLUS II ™ 1/4" Charging Hose
(Seal Right™, FlexFlow and Ball-Valve ends)
YELLOW JACKET PLUS II ™
3/8" Charging Hose
YELLOW JACKET PLUS II ™
1/2" and 5/8" Charging Hose
• All-weather flexible
• Dependable
• Adjust-a-Valve™ Opener – Patented valve
core depressor. Easily open all out of
tolerance Schrader valves. (SealRight
hoses offer different technology.)
• PLUS II ™ Hoses with
double barrier protection:
– Nylon barrier meets UL
permeation requirements.
• PLUS II ™ Hoses:
– Nylon barrier meets UL permeation
requirements.
• Adjust-a-Valve™ Opener –
Patented valve core
depressor allows you
to easily open all
troublesome,
out of tolerance
Schrader valves.
• PLUS II ™ hoses offer double barrier
protection:
– Nylon permeation barrier meets UL
requirements.
– Moisture barrier provides improved
resistance to moisture migration which
contaminates expensive refrigerants.
– Moisture barrier provides improved resistance
to moisture migration which contaminates
expensive refrigerants.
– Moisture barrier provides
improved resistance to
moisture migration which
contaminates expensive
refrigerants.
– Higher working pressure.
• Large ID reduces vacuum time substantially over
1/4" or 3/8" hose – allowing techs to pull a faster
vacuum.
• Faster refrigerant transfer and faster charging on
large systems.
• Wide selection of fittings are available.
• Operating temperature -20° to 200°F.
• Rubber layer for permeation, braid for
strength, and outer cover for protection.
• Fully UL recognized assemblies
(File SA9737).
Temp: -20° to 180°F
(-28.8° to 82.2°C)
Temp: -20° to 180°F
(-28.8° to 82.2°C)
Temp: -20° to 200°F
(-28.8° to 93.3°C)
Temp: -20° to 200°F
(-28.8° to 93.3°C)
Burst: 2500 psi (172 bar)
minimum
Burst: 4000 psi (276 bar) minimum
Burst: 3000 psi (207 bar) minimum
Burst: 3000 psi (207 bar) minimum
Working:
500 psi (34 bar) maximum
Working:
800 psi (55 bar) maximum
Working:
600 psi (41 bar) maximum
Working:
600 psi (41 bar) maximum
Safety factor: 5 to 1
Safety Factor: 5 to 1
Safety factor: 5 to 1
Safety factor: 5 to 1
Available Lengths:
6 inches to 100 feet
Available Lengths:
12 inches to 100 feet
Available Lengths:
12 inches to 100 feet
Available Lengths:
12 inches to 100 feet
YELLOW JACKET PLUS II ™ CHARGING HOSES for the environment
YELLOW JACKET PLUS II Hoses
feature multi-laminate construction
with double barrier protection to
help contain the smaller molecules
of newer refrigerants.
1. Nylon permeation barrier
meets SAE requirements J2196 for
Cover for
protection Braid for Rubber for
strength permeation
protection
CFC, HCFC and HFC control and
system performance.
Nylon
permeation and
moisture barrier
2. Moisture barrier provides
maximum resistance to moisture
migration which contaminates
expensive refrigerants.
UL recognized assembly.
Technical paper available on www.yellowjacket.com
Adjust-A-Valve-Opener™.
High volume
With this patented
flow pattern
valve core depressor,
you easily open all
troublesome out-oftolerance Schrader
valves. Simply adjust
height with needle
nose pliers. Use again
and again. Replacement is convenient.
24
Hose safety inspection –
Inspect your hoses on a regular basis.
If your hoses are more than 5 years old,
we recommend that you replace them.
Since 1964, YELLOW JACKET 1/4"
Charging Hoses have “year of
manufacture” coded on the rim of the
nut. A series of dots, I’s, X’s, O’s or A’s
following YELLOW JACKET indicates the
years as follows:
6
1
6 IIIIII
1I
6 XXXXXX
1X
6 OOOOOO
1O
6 AAAAAA
1A
6 BBBBBB
1964
1970
1971
1976
1977
1982
1983
1988
1989
1994
1995
5 BBBBB
1996
4 BBBB1997
3 BBB 1998
2 BB
1999
1B
2000
6 CCCCCC 2001
5 CCCCC
2002
4 CCCC
2003
3 CCC 2004
2 CC
2005
1C
or
2006
YELLOW JACKET ORIGINAL 1/4" CHARGING HOSES
• 2500 psi (172 bar) min. burst and
500 psi (34 bar) max. working
pressure mean a 5-to-1 safety factor
• Specially formulated rubber tube
resists most refrigerants and assures
long work life
• Blow-off groove channels refrigerant
L.
Y - yellow
out of the front of the nut to help
prevent spray back
• 1/4" straight x 1/4" 45° angle
fitting
• Hose cover pin-pricked to resist
bubbling and bursting
• 6" to 100' lengths in yellow, red,
blue, and white. Longer lengths
are available
• Brass fittings
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
3 Paks
NOTE: Not all hose products shown
are stocked; many are made-to-order
with a lead time of 2-3 days.
UPC#
Description/Quantity
19010
19020
1/4" gasket (6 pak)
Valve depressor (3 pak)
Replacement gasket (10 pak)
19302
Adjust-a-Valve Opener (10 pak)
• Each hose color-coded for your
convenience
B - blue
W - white
R - red
3 - Pak
12"
24"
11012 HA12Y
11024 HA24Y
11212
11224
HA12B
HA24B
11412 HA12W
11424 HA24W
11612 HA12R
11624 HA24R
Y, B,
W*
36"
48"
60"
11036 HA36Y
11048 HA48Y
11060 HA60Y
11236
11248
11260
HA36B
HA48B
HA60B
11436 HA36W
11448 HA48W
11460 HA60W
11636 HA36R
11648 HA48R
11660 HA60R
72"
96"
11072 HA72Y
11096 HA96Y
11272
11296
HA72B
HA96B
11472 HA72W
11496 HA96W
11672 HA72R
11696 HA96R
10’
12’
25’
11110 HA120Y
11112 HA144Y
11125 HA300Y
11310
11312
11325
HA120B
HA144B
HA300B
11510 HA120W
11512 HA144W
11525 HA300W
11710 HA120R
11712 HA144R
11725 HA300R
50’
75’
100’
11150 HA600Y
11175 HA900Y
11200 HA1200Y
11350
11375
11399
HA600B
HA900B
HA1200B
11550 HA600W
11575 HA900W
11599 HA1200W
11750 HA600R
11775 HA900R
11799 HA1200R
SPECIAL 1/4" ORIGINAL CHARGING HOSES
YELLOW JACKET 1/4" yellow charging
hoses with special fittings include
L.
1/4" fl. x
1/4" 90˚ fl.
36" 12036 HL36
1/4" fl. x
1/4" fl.
straight, 3/8" and 90° fittings. Other
colors are available.
1/4" fl. x
3/8" fl.
90° for tight areas.
13036 HS36 14036 HB36
48" 12048 HL48 13048 HS48 14048 HB48
60" 12060 HL60 13060 HS60 14060 HB60
72" 12072 HL72 13072 HS72 14072 HB72
Longer lengths available. Please specify.
UPC#
Description/Quantity
19010
19020
1/4" gasket (6 pak)
Valve depressor (3 pak)
Replacement gasket (10 pak)
19302
Adjust-a-Valve Opener (10 pak)
VACUUM AND
CHARGING HOSES
The YELLOW JACKET original charging
hose has been the standard of the
industry for more than 50 years.
Features in addition to the individual
hose inspection, full size brass nuts,
adjustable valve opener, and other
features and benefits on page 24 –
HL
1/4" x 1/4"
HS
1/4" x 1/4"
HB
1/4" x 3/8"
R, Y,
B
R, W,
B
11963
11964
11965
11983
11984
11985
11973
11974
11975
11966
11968
11986
11988
11976
11978
* Color-coded: Y - yellow; B - blue;
W - white; R - red
FITTINGS AVAILABILITY FOR 1/4"
PREMIUM AND PLUS II HOSES
Type
Str 45° 90°
1/8" Female flare
3/16" Female flare
1/4" Female flare
1/4" Female SealRight™
3/8" Female flare
5/16" Female flare
1/4" Male flare
1/8" NPT Male
1/4" NPT Male
1/2" Female Acme
14 mm Male
Not all hose and fitting combinations are
listed in this catalog. Ask for specifics.
25
YELLOW JACKET PLUS II ™ 1/4" CHARGING HOSES
with double barrier protection
UL recognized assemblies (File SA9737)
YELLOW JACKET PLUS II Hoses have
proven performance benefits of the
original line, plus double barrier
protection for CFC, HCFC and HFC
(R-404A, R-134a, R-507, R-407C,
R-410A, etc.).
1. Nylon permeation barrier meets
UL requirements. 1/4" PLUS II
hose is also a UL 1963 recognized
component for R-12, R-22, R-500,
R-502 and R-134a.
2. Moisture barrier provides improved
resistance to moisture migration
which contaminates expensive
refrigerant.
Other features include 4000 psi
(276 bar) min. burst and 800 psi
(55 bar) max. working pressure for
a 5-to-1 safety factor.
Color-coded 3-Pak
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
PLUS II Hoses - standard 1/4" fittings
L.
Yellow
Blue
Red
3 - Pak
12"
24"
36"
21012
21024
21036
21212
21224
21236
21612
21624
21636
–
–
21983
48"
60"
72"
96"
10'
12'
21048
21060
21072
21096
21110
21112
21248
21260
21272
21296
21310
21312
21648
21660
21672
21696
21710
21712
21984
21985
21986
21988
–
–
25'
50'
75'
100'
21125
21150
21175
21200
21325
21350
21375
21399
21725
21750
21775
21799
–
–
–
–
Multi-length 3-Paks - 21982 two 36", one 60"
21981 two 36", one 72"
UPC#
Description
19020
19302
Replacement gasket (10 pak)
Adjust-a-Valve Opener (10 pak)
YELLOW JACKET PLUS II 1/4" HOSE with FlexFlow™ valve
• Valve handle position shows when
valve is opened or closed
• Improved smaller ergonomic valve
with zero restriction for maximum
flow. Metal handle
• Flexible length of hose between
valve and fitting makes access
easier to tight areas
• 4000 psi (276 bar) min. burst
and 800 psi (55 bar) max. working
pressure
UL recognized assemblies (File SA9737)
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
9" FLEXFLOW™ AND LOW LOSS
ADAPTER HOSES
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
25002
Description
25202
29001
29201
1/4" yellow ball valve adapter
1/4" blue ball valve adapter
26002
29601
29980
1/4" red ball valve adapter
3-pak: 29001, 29201, 29601
93842
1/4" compact ball valve – 3 Pak
93843
1/4" compact ball valve – 45°
29201
29601
*93842 is a 3 pak of 93843.
93842 (3 pak)*
Easy retrofit of existing PLUS II hoses
with ball valve capabilities. Flexible
hose between valve and fitting for
handling in tight areas.
26
Compact Ball Valve Assemblies
UPC#
UPC#
Description
19011
3/8" Replacement gasket (10 pak)
19026
19020
19302
3/8" “O”-ring (10 pak)
1/4" Replacement gasket (10 pak)
Adjust-a-Valve Opener (10 pak)
FlexFlow valve 8" from angle end
L.
Yellow
Blue
Red
3 - Pak
36"
48"
25036
25048
25236
25248
25636
25648
25983
25984
60"
72"
25060
25072
25260
25272
25660
25672
25985
25986
96"
10'
12'
25096
25110
25112
25296
25310
25312
25696
25710
25712
25988
–
–
25'
50'
25125
25150
25325
25350
25725
25750
–
–
75'
100'
25175
25199
25375
25399
25775
25799
–
–
UPC#
Description
19020
19302
Replacement gasket (10 pak)
Adjust-a-Valve Opener (10 pak)
FlexFlow™ Assemblies
UPC#
Description
25002
25202
25602
25980
25802
26002
26202
1/4" yellow FlexFlow adapter
1/4" blue FlexFlow adapter
1/4" red FlexFlow adapter
3-pak: 25002, 25202, 25602
1/4" heavy duty FlexFlow adapter
3/8" heavy duty FlexFlow adapter
Yellow std. “B” FlexFlow adapter
27002
19095
93833
93832
25001
25201
Acme 1/2" yellow FlexFlow adapter
Set of 2 handles and screws
1/4" replacement ball valve only
3/8" replacement ball valve only
Replacement yellow hose only
Replacement blue hose only
25601
Replacement red hose only
Underwriters Laboratories Inc.
Registered Component Mark.
YELLOW JACKET PLUS II™ 1/4" HOSE with compact ball valve end
• Full flow valve for faster recovery
• Low loss fitting
• Hose and ball valve rated for higher
pressure. 4000 psi (276 bar) min.
burst and 800 psi (55 bar) max.
working pressure uses standard
gasket and valve opener
UL recognized assemblies (File SA9737)
PLUS II 1/4" HOSE with SealRight™
low loss anti-blow back fitting
UL recognized assemblies (File SA9737)
• Low loss anti-blowback SealRight
fitting immediately traps refrigerant
in the hose when disconnected,
helping meet non-venting regulations
and prevent finger burns
• 45° end for easy installation in tight
areas
L.
Yellow
Blue
Red
3 - Pak
36"
48"
60"
72"
96"
10'
12'
25'
50'
29036
29048
29060
29072
29096
29110
29112
29125
29150
29236
29248
29260
29272
29296
29310
29312
29325
29350
29636
29648
29660
29672
29696
29710
29712
29725
29750
29983
29984
29985
29986
29988
–
29175
29375
29775
–
29199
29399
29799
–
UPC#
Description
75'
19020
19302
Replacement gasket (10 pak)
Adjust-a-Valve Opener (10 pak)
100'
• Gaskets resist deterioration from
existing CFCs, plus new HFC
refrigerants and oils
• Available with SealRight fittings
on both ends
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
• 4000 psi (276 bar) min. burst, 800
psi (55 bar) max. working pressure
See page 106 for pliers for
disassembling end.
Use PLUS II hose with compact ball valve
for R-410A, (see above, below and page 34).
UPC#
Description
19020
19037
Replacement gasket (10 pak)
SealRight “O”-ring (10 pak)
19302
Adjust-a-Valve Opener (10 pak)
–
–
–
VACUUM AND
CHARGING HOSES
• Improved compact design ball valve
with metal handle at end of hose fits
tight areas and traps all the gas.
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
PLUS II hose with ball valve end
45˚ SealRight fitting at one end
L.
12"
Yellow
22012
Blue
22212
Red
22612
3 - Pak
–
24"
36"
22024
22036
22224
22236
22624
22636
–
22983
48"
60"
72"
22048
22060
22072
22248
22260
22272
22648
22660
22672
22984
22985
22986
96"
10'
22096
22110
22296
22310
22696
22710
22988
–
12'
25'
50'
75'
22112
22125
22150
22175
22312
22325
22350
22375
22712
22725
22750
22775
–
–
–
–
100'
22200
22399
22799
–
Multi-length 3-Paks - 22982 two 36", one 60"
22981 two 36", one 72"
UL recognized assemblies (File SA9737)
YELLOW JACKET PLUS II 1/4" HOSE for 5/16" (1/2 – 20 thread) service ports for R-410A
• Compatible with both POE and
PVE oils
• Operating temperature -20° to 180°F.
(-28.8° to 82.2°C)
UL recognized assemblies (File SA9737)
• Available with standard fittings or
compact ball valve
• 4000 psi (276 bar) min. burst and
800 psi (55 bar) max. working
pressure
• Moisture barrier provides maximum
resistance to moisture migration
which contaminates expensive
refrigerants
PLUS II hose with 1/4" (7/16 – 20) Female
flare on manifold connection and 5/16"
(1/2 – 20) Female flare angled on service end
Standard fitting
L. Yellow
Blue
Red
3 - Pak
36"
60"
72"
21403
21405
21406
21423
21425
21426
21463
21465
21466
21483
21485
21486
PLUS II hose with 5/16" (1/2 – 20) Female
flare on manifold connection and 5/16"
(1/2 – 20) Female flare angled on service end
Standard fitting
L. Yellow
Blue
Red
3 - Pak
36"
60"
72"
29403
29423
29463
29483
60"
72"
29405
29406
29425
29426
29465
29466
29485
29486
21523
21525
21526
21563
21565
21566
21583
21585
21586
Compact ball valve
(R&B 1/4" x 5/16" BV) (Y 1/4" x 1/4" BV)
L. Yellow
Blue
Red
3 - Pak
36"
60"
72"
Compact ball valve
(R&B 1/4" x 5/16" BV) (Y 1/4" x 1/4" BV)
L. Yellow
Blue
Red
3 - Pak
36"
21503
21505
21506
29003
29005
29006
29203
29205
29206
29603
29605
29606
29993
29995
29996
Replacement parts
Size
1/4" and 5/16"
Repl.
Gasket
Adjust-aValve
Opener
19020
19302
27
YELLOW JACKET PLUS II ™ 3/8"
"B" CHARGING HOSE
Hose uses PLUS II hose technology
which includes double barrier and
higher working pressure.
Special design puts YELLOW JACKET
features in a larger volume hose for
fast, high vacuum or charging.
L.
Yellow
ED,ND
R
IN E A W
BLUELLO
Y
3/8" Replacement gasket (10 pak)
3/8" “O”-ring (10 pak)
3/8" fl. 1/4" fl.str.
x 3/8" x 1/4" fl.
90°
45°
Red
36" 14536 B36
48" 14548 B48
60" 14560 B60
27836
27848
27860
28036
28048
28060
26236
26248
26260
18136
18148
18160
28236
28248
28260
28436
28448
28460
20036
20048
20060
20436
20448
20460
72"
96"
10'
12'
25'
50'
27872
27896
27910
27912
27925
27950
28072
28096
28110
28112
28125
28150
26272
26296
26310
26312
26325
26350
18172
18196
18210
18212
18225
18250
28272
28296
28310
28312
28325
28350
28472
28496
28510
28512
28525
28550
20072
20096
20110
20112
20125
20150
20472
20496
20510
20512
20525
20550
27975
27999
28175
28199
26375
26399
18275
18299
28375
28399
28575
28599
20175
20199
20575
20599
14572
14596
14610
14612
14625
14650
B72
B96
B120
B144
B300
B600
L.
UPC #
Part #
12"
18612
CVX-12
1/4" heavy duty
1/4" Male flare x 3/4" NPS
12"
18912
CVY-12
3/8" heavy duty
3/8" Male flare x 3/4" NPS
72"
18072
CVH-72
1/4" original
1/4" Female flare x 3/4" NPS
72"
18372
CVB-72
3/8" standard
3/8" Female flare x 3/4" NPS
Cylinder valve adapters only. See page 36.
Description
19011
19026
Other selections
3/8" fl. 3/8" fl. str. x 3/8" 45°
x FlexFlow Yellow Blue
Red
• Operating temperature -20° to
200°F (-28.8° to 93.3°C)
• 3/8" hose 3000 psi (207 bar) min.
burst, 600 psi (41 bar) max.
working pressure
• 1/4" heavy duty hose 3500 psi
(241 bar) min. burst, 900 psi
(62 bar) max. working pressure
Type
UPC#
Blue
75' 14675 B900
100' 14699 B1200
Designed for finger
tight operation on
125 lb. and 145 lb.
refrigerant cylinders.
Gaskets seal
without wrenches.
• Larger selection of fittings to fit
customer needs
• Burst pressure is 3000 psi
(207 bar) min. burst with 600 psi
(41 bar) max. working pressure
Most commonly selected
3/8" fl. str. x 3/8" fl. str
CYLINDER VALVE HOSES
with finger tight drum fitting
• Operating temperature -20° to 200°F.
(-28.8° to 93.3°C)
Fittings
UPC#
Description
18001
Replacement gasket (10 pak)
Ounces of liquid held per foot
of hose at 80°F.
Hose
R-12 R-22 R-502 R-134a R-404A R-410A
1/4"
Original
.34
.31
.32
.31
.28
.28
1/4"
PLUS II
.36
.33
.34
.33
.29
.29
.85
3/8"
Standard
.77
.78
.77
.68
.68
.63
.64
.64
.56
.56
3/8"
Heavy
Duty
.70
YELLOW JACKET AUTOMOTIVE MANIFOLD HOSES for R-134a systems
manufactured specifically for automotive
applications. Threads are 1/2" Acme
Female, 14 mm Male and 1/2" Acme
SealRight™ fittings.
• 4000 psi (276 bar) min. burst, 800
psi (55 bar) max. working pressure
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
UL recognized assemblies (File SA 9737)
These 1/4" hoses combine PLUS II
hose with Acme fittings to meet SAE
requirements. You get PLUS II
double-barrier protection in a hose
28
UPC#
Description
19020
Replacement gasket for 1/4" and
1/2" Acme hose (10 pak)
Yellow
Red
Blue 3 - Pak
SealRight 1/2" Fe. 1/2" Fe.
L. Straight Acme
Acme
x 45° x 14 mm x 14 mm
Male
Male
36"
27436
27636
27236
—
48"
27448
27648
27248
—
60"
27460
27660
27260
27102
72"
27472
27672
27272
27101
96"
27496
27696
27296
27104
10'
27510
27710
27310
27103
Longer lengths available. Please specify.
These fittings are not suitable for regular
HVAC&R applications.
NOTE: These hoses meet SAE requirements J2196 and are UL 1963 recognized
components for refrigerants R-12, R-22, R-500, R502 and R-134a.
YELLOW JACKET PLUS II™ 1/4"
HEAVY DUTY CHARGING HOSE
YELLOW JACKET PLUS II 3/8"
HEAVY DUTY COMBINATION
CHARGING/HI-VACUUM HOSE
L.
12"
24"
36"
15012 HCA-12"
15024 HCA-24"
15036 HCA-36"
–
–
25836
–
–
29836
15212
15224
15236
HCL-12"
HCL-24"
HCL-36"
15412
15424
15436
HCS-12"
HCS-24"
HCS-36"
48"
60"
72"
96"
10’
15048
15060
15072
15096
15110
HCA-48"
HCA-60"
HCA-72"
HCA-96"
HCA-120"
25848
25860
25872
25896
25910
29848
29860
29872
29896
29910
15248
15260
15272
15296
HCL-48"
HCL-60"
HCL-72"
HCL-96"
15448
15460
15472
15496
HCS-48"
HCS-60"
HCS-72"
HCS-96"
12’
25’
50’
75’
100’
15112
15125
15150
15175
15199
HCA-144"
HCA-300"
HCA-600"
HCA-900"
HCA-1200"
25912
25925
25950
25875
25999
29912
29925
29950
29975
29999
Pull a vacuum
much faster with this
3/8" heavy duty hose
than with the 1/4" hose.
• Permeation resistant PLUS II barrier
Black only. Longer lengths available.
Please specify.
The position of the new FlexFlow valve
lets you know for sure when it’s fully
opened securely closed or anywhere
between.
• Pulls 75 micron vacuum or better
on 36" hose
• Operating temperature -20° to 200°F
(-28.8° to 93.3°C)
Most commonly selected
3/8" fl. str.
3/8" fl. str.
x 3/8" fl. str.
& FlexFlow
L.
Shown
with
FlexFlow
control
valve
Other selections
HCL Hose
HCS Hose
Str. x 90°
Str. x Str.
UPC#
Description
19020
Replacement gasket (10 pak)
VACUUM AND
CHARGING HOSES
Heavy-duty
construction
Shown
for substantially
with
compact
increased
ball valve
service life.
PLUS II barrier
reduces permeation.
Flexibility for all-weather easy
handling.
• 3500 psi (241 bar) min. burst,
900 psi (62 bar) max. working
pressure.
• Operating temperature -20° to 200°F
(-28.8° to 93.3°C)
Most commonly selected
HCA Hose
Hose with Hose with
FlexFlow ball valve
Str. x Angle
• 3000 psi (207 bar) min. burst, 600
psi (41 bar) max. working pressure
3/8" fl.
x 3/8"
45°
Other selections
3/8" fl.
3/8" fl. x
x 3/8"
1/4" 45°
90°
1/4" fl.
x 1/4"
45°
36"
48"
15636 BC-36"
15648 BC-48"
26036
26048
19636
19648
19836
19848
16236 BCA-36"
16248 BCA-48"
20236
20248
60"
72"
15660 BC-60"
15672 BC-72"
26060
26072
19660
19672
19860
19872
16260 BCA-60"
16272 BCA-72"
20260
20272
96"
10'
12'
15696 BC-96"
15710 BC-120"
15712 BC-144"
26096
26110
26112
19696
19710
19712
19896
19910
19912
16296 BCA-96"
Longer lengths
available on
hose in this chart.
Please specify.
Longer than 8'
not recommended
for evacuation.
20296
20310
20312
UPC#
Description
25'
50'
15725 BC-300"
15750 BC-600"
26125
26150
19725
19750
19925
19950
19026
19011
“O”-ring
Replacement gasket
75'
100'
15775 BC-900"
15799 BC-1200"
26175
26199
19775
19799
19975
19999
20325
20350
20375
20399
YELLOW JACKET PLUS II™ 1/2" and 5/8" HEAVY DUTY COMBINATION CHARGING/HI-VACUUM HOSE
•
•
•
•
Pull a more complete vacuum
Faster refrigerant transfer
Faster charging on large systems
3000 psi (207 bar) min. burst, 600
psi (41 bar) max. working pressure
1/2" and 5/8" assemblies
• Various fittings available on request
• 1/4" access valve connection
standard on one end of CA and
DA hoses
• Operating temperature -20° to 200°F
(-28.8° to 93.3°C)
Most commonly selected
Heavy-use construction with PLUS II
barrier technology for use with most
refrigerants. Reduces permeation and
vacuum loss. Features:
• Large ID reduces vacuum time
substantially over 1/4" or 3/8" hose
UPC#
Description
19015
19020
19011
1/2" and 5/8" Replacement gaskets
1/4" Replacement gasket
3/8" Replacement gasket
L.
36"
48"
60"
72"
“C” 1/2" fl.
x 1/2" fl.
15836
15848
15860
15872
C-36"
C-48"
C-60"
C-72"
“D” 5/8" fl.
x 5/8" fl.
16036
16048
16060
16072
D-36"
D-48"
D-60"
D-72"
“CA” 1/4"
angle end
x 1/2" fl.
16436
16448
16460
16472
CA-36
CA-48
CA-60
CA-72
Other selections
“DA” 1/4"
angle end
1/2" fl.
x 5/8" fl.
x 3/8" fl.
16636
16648
16660
16672
DA-36
DA-48
DA-60
DA-72
3/8" fl.
x 3/8" fl.
19236
19248
19260
19272
20636
20648
20660
20672
96" 15896 C-96" 16096 D-96" 16496 CA-96 16696 DA-96
19296
10' 15910 C-120" 16110 D-120" 36" hose will pull to
19310
12' 15912 C-144" 16112 D-144" 25 microns and lower.
19312
25' 15925 C-300" 16125 D-300" Hoses longer than 8' not
19325
50' 15950 C-600" 16150 D-600" recommended for evacuation.
19350
Black only. Longer lengths available. Specify type, length and fitting combination.
20696
20710
20712
20725
20750
29
YELLOW JACKET PLUS II 3/4"
HEAVY DUTY CHARGING HOSE
YELLOW JACKET AMMONIA CHARGING HOSE
Designed with steel quick couplers at
both ends. Features include:
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
• Regular CH20 gaskets for 1/4"
gasket (19010, 19020). CH11 gaskets
for 3/8" (19011)
Large 3/4" I.D. designed to save
time in charging or evacuation of
centrifugals and other large systems.
• Now with PLUS II barrier
technology to reduce permeation
3/4" fl. x
3/4" fl. –
“O”-ring seal
3/4" hex x
3/4" hex copper
gasket seal
12"
24"
18412 E-12"
18424 E-24"
20812
20824
36"
48"
60"
18436 E-36"
18448 E-48"
18460 E-60"
20836
20848
20860
72"
96"
18472 E-72"
18496 E-96"
20872
20896
10'
12'
25'
18510 E-120"
18512 E-144"
18525 E-300"
20910
20912
20925
50'
18550 E-600"
20950
NHA-48"
NHA-72"
NHA-96"
NHA-120"
NHA-144"
19448
19472
19496
19510
19512
NBC-48"
NBC-72"
NBC-96"
NBC-120"
NBC-144"
Steel half union ammonia fittings
UPC# 16801 (44372) – 1/4" Male fl. x
1/4" NPT Male Str
UPC# 16802 (44376) – 1/4" Male fl. x
1/4" NPT Male 90°
UPC# 16803 – 3/8" Male fl. x
1/4" NPT Male
AMMONIA HOSE – (permanent installation)
Operating temperature -20° to 180°F
(-28.8° to 82.2°C).
UPC# 1/4" UPC# 3/8" UPC# 1/2"
L. NPT Male NPT Male NPT Male
• Now available with hex fittings
L
16848
16872
16896
16910
16912
3/8" Str. fl.
both ends
UPC# Part#
NH3 manifolds pages 51 and 58.
• 3000 psi (207 bar) min. burst,
600 psi (41 bar) max. working
pressure
• Operating temperature -20° to 200°F
(-28.8° to 93.3°C)
48"
72"
96"
10'
12'
• 1/4" – 3500 psi (241 bar) min. burst,
900 psi (62 bar) max. working
pressure
• 3/8" – 3000 psi
(207 bar) min.
burst, 900 psi
Available
black only
(62 bar) max.
working pressure
• Constructed for heavy duty use
with most refrigerants
• Available with steel 3/4" Female,
3/4" Male flares or 3/4" Male pipe
1/4" Str. fl.
x 1/4" 45°
L. UPC# Part#
Specially
designed 1/2" I.D.
hose with steel fittings,
2000 psi (138 bar) min. burst, 400
psi (28 bar) max. working pressure.
6'
78506
78406
8'
78508
78408
10'
78510
78410
12'
78512
78412
Other lengths up to 50" available.
Please specify length and size.
78306
78308
78310
78312
YELLOW JACKET FUEL OIL ASSEMBLY HOSES
Reinforced hose designed for quick
pump to nozzle connection and oil
burner connections.
Flexible to absorb vibration and
swelling while providing positive
cut-off.
• 1250 psi (86 bar) min. burst, 250 psi
(17 bar) max. working pressure
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
Longer lengths available
UPC #
Description
Fittings
78041
Pump to nozzle connector
3/16" Fe. fl. x 3/16" Fe. fl.
12"
78042
78112
Pump to nozzle connector
Pump to nozzle connector
or gauge to pump
1/4" Fe. fl. x 1/4" Fe. fl.
1/8" NPT Fe. swivel x 1/8" NPT Male
12"
12"
Lengths
UPC#
Description
78043
Pump to nozzle connector
3/16" Fe. fl. x 3/16" Fe. fl.
18"
19012
Replacement gasket (10 pak)
78044
Pump to nozzle connector
1/4" Fe. fl. x 1/4" Fe. fl.
18"
OIL PUMP VIBRATION ELIMINATOR
Reinforced rubber hose helps eliminate
noise and vibration when installed in a
heating system.
• 1250 psi (86 bar) min. burst, 250 psi
(17 bar) max. working pressure.
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C).
12 inch OA
30
UPC #
Description
Fittings
78012
Oil burner connector
3/8" Male flare x 1/4" NPT Male
General info and specs for all stainless steel hose assemblies below
FLARE ASSEMBLY
for display cases etc.
QUICK COUPLER ASSEMBLY – for vacuum & charging
Oversized to increase flow and speed evacuation.
Pull 25 microns and better on 36" length.
Brass quick coupler.
Other features:
• Standard 45° angle at one end
on 1/4" and 3/8"; 90° available
• Straight fittings only on 1/2", 5/8"
and 3/4"
Straight,
45° or 90°
available
OAL
Str. x
45° 1/4" I.D.
Str. x
45° 3/8" I.D.
Str. x
Str. 1/2" I.D.
Str. x
Str. 1/2" I.D.
Str. x
Str. 3/4" I.D.
36"
48"
81636
81648
81736
81748
81836
81848
81936
81948
82036
82048
60"
81660
81760
81860
81960
82060
SWEAT FITTING ASSEMBLY
Sweat x Sweat
Manufactured with copper sweat ends.
• Male sweat to fit inside mating tube
VACUUM AND
CHARGING HOSES
YELLOW JACKET® stainless steel
Stainless Steel Hose Specifications
assemblies are 300 series corrugated
Temperature/pressure
Size
Max psi working*
Flexing
Permanent
hose and braid for applications
correction
bend radius
bend radius
where temperature and pressure
1/4"
1275 (88 bar)
5.5"
1"
could be a problem.
68°F – 1.00
3/8"
1000 (69 bar)
6.5"
1-1/4"
200°F
– .86
With stainless steel braid wrapping
1/2", 5/8"
1200 (83 bar)
8.5"
1-1/2"
300°F
– .80
a stainless steel core, all hoses
3/4", 7/8"
725 (50 bar)
10"
2"
400°F
– .78
on this page prevent permeation and
1", 1-1/8"
700 (48 bar)
11.5"
2-3/4"
500°F
– .77
moisture infusion. Use with all
1-1/4", 1-3/8"
550 (38 bar)
13"
3-1/4"
800°F
– .76
standard refrigeration oils and
1-1/2"
450 (31 bar)
15"
3-3/4"
900°F
–
.74
refrigerants, as well as the new
2"
450 (31 bar)
17.5"
5"
1000°F
–
.70
alternative oils and refrigerants
2-1/2"
300 (21 bar)
21"
7"
including R-123.
3"
350 (24 bar)
23"
9"
Standard and custom length
* PSI at 68°F with a four to one safety factor. Core is T-321 SS with 300 Series SS braid.
assemblies are made to order.
Applications: vacuum and charging, vibration isolation, movable components,
Allow 2-3 days for shipment.
and permanent application.
Minimum length 12".
Straight Only
Female
Male
Sweat Fitting
Sweat Fitting
86136
1/4" x 36"
85136
1/4" x 36"
86236
86336
3/8" x 36"
1/2" x 36"
85236
85336
3/8" x 36"
1/2" x 36"
86436
86536
86636
5/8" x 36"
3/4" x 36"
7/8" x 36"
85436
85536
85636
5/8" x 36"
3/4" x 36"
7/8" x 36"
86736
86836
1-1/8" x 36"
1-3/8" x 36"
85736
85836
1-1/8" x 36"
1-3/8" x 36"
• Female sweat to fit outside mating
tube
Stainless steel assemblies are made
with a combination of male and
female flares. Custom assemblies can
be made.
Fl. size
Male fl. Male fl. Fe. fl.
x length x Male fl. x Fe fl. x Fe. fl.
1/4" x 36"
1/4" x 48"
3/8" x 36"
82136
82148
82236
83136
83148
83236
84136
84148
84236
3/8" x 48"
1/2" x 36"
1/2" x 48"
5/8" x 36"
5/8" x 48"
82248
82336
82348
82436
82448
83248
83336
83348
83436
83448
84248
84336
84348
84436
84448
3/4" x 36"
3/4" x 48"
82536
82548
83536
83548
84536
84548
NOTE: Stainless steel (pg. 31) and
Teflon (pg. 32) hoses are made-toorder; lead-time 2-3 working days.
Get maximum benefit from your YELLOW JACKET metal hoses –
Keep your hoses on the job longer and the YELLOW JACKET warranty in effect by avoiding
sharp bending and twisting that causes early failure. The warranty does not cover fatigue
failure. Replace gaskets in quick couplers as needed to ensure a proper sealing.
NOTE: Custom lengths are available
for all stainless steel hose assemblies
on this page.
31
YELLOW JACKET HIGH PRESSURE CONTROL HOSE
for HFC, HCFC and CFC refrigerants
ORIGINAL
PRESSURE CONTROL HOSE
• Clear zinc chromate finish
• Yellow color makes hose easily
visible inside system
• 3000 psi (207 bar) min. burst 600 psi
(41 bar) max.working pressure
• Hex style fittings with 1/4" SAE
thread. Straight or 90° with copper
gaskets
YELLOW JACKET
pressure
control hose is
constructed of
a thermoplastic
polymer inner
tube and cover
to eliminate the
vibration failures of copper capillary
tube installations.
Black Hose
1/4" Hex Fittings Assemblies
Operates to 600 psi and 200°F
L.
Str. x Str.
Str. x 90˚
• Operating temperature
-20° to 266°F (-28.8° to 130°C)
Yellow Hose
UPC Part Numbers
Length*
(assembly) Str. End x Str. End
• The higher temperature ratings
up to 266°F eliminate the failures
caused by maximum loads on
rubber hoses
• Polyester braid reinforcement
with high tensile strength and high
modulus withstand higher pressures
Str. End x 90˚ End
12"
18"
78612
78618
78712
78718
24"
30"
78624
78630
78724
78730
36"
48"
60"
78636
78648
78660
78736
78748
78760
72"
78672
78772
12"
18"
24"
78212
78218
78224
78113
78118
78124
30"
36"
48"
60"
78230
78236
78248
78260
78130
78136
78148
78160
3/8" Hex Fittings Assemblies
Operates to 500 psi and 200°F
UPC#
Description
59652
1/4" replacement copper gasket (10 pak)
12"
18"
00101
00102
N/A
N/A
24"
36"
00103
00104
N/A
N/A
48"
60"
00105
00438
N/A
N/A
* Special lengths are readily available
YELLOW JACKET PTFE HOSE for wide variety of industrial applications including CO2
products, food processing and more
• 3/16" – 3/4" Female flare swivel
brass fittings; 1/8" – 1" NPT Male
brass fittings
Specially-designed hose provides
strength with stainless steel braid over
a PTFE core. Features:
• Temperature range from -65°
to 450°F (-53.9° to 232.2°C)
Brass Fe. flare swivels each end
Hose
I.D.
Min.
burst
Max.
W.P.
Min.
bend
• Minimum length 12"
• Variety of applications – high
and low pressure chemical lines,
hot water, steam, oil, air, petroleum
• Resistance to most corrosive
materials
Hose specifications
• 1/4" 90° x 1/4" straight flare
UPC#
Description
59652
Replacement gasket (10 pak)
Brass male pipe each end
Flare Thread
size
size
UPC# – overall length
12"
18"
24"
36"
48"
Pipe
thd.
UPC# – overall length
12"
18"
24"
36"
1/8"
12000
3000
2"
3/16"
3/8-24
31112
31118
31124
31136
31148
–
–
–
–
–
3/16 "
3/16"
12000
12000
3000
3000
2"
3"
1/4"
1/4"*
7/16-20
7/16-20 (1)
31212
31218
31224
31236
31248
1/8"
32212
32218
32224
32236
1/4"
12000
3000
3"
5/16"
1/2-20
31012
31312
31018
31318
31024
31324
31036
31336
31048
31348
–
–
–
–
–
–
–
–
–
–
5/16"
13/32"
12000
8000
3000
2000
4"
5.2"
3/8"
1/2"
5/8-18
3/4-16
31412
31512
31418
31518
31424
31524
31436
31536
31448
31548
1/4"
3/8"
32412
32512
32418
32518
32424
32524
32436
32536
1/2"
5/8"
7/8"
8000
6000
4400
2000
1500
1100
6.5"
7.7"
8.7"
5/8"
3/4"
–
7/8-14
1-1/16-14
–
31612
31712
–
31618
31718
–
31624
31724
–
31636
31736
–
31648
31748
–
1/2"
3/4"
1"
32612
32712
32812
32618
32718
32818
32624
32724
32824
32636
32736
32836
NOTE: Not recommended for refrigerants because of permeation rate.
Note: Above pressures in psi
32
Brass fittings standard. Stainless available if specified,
except for 3/8" and 3/4" flare.
(1) 1/4"
90˚ x 1/4" straight hose
Brass fittings standard. Stainless fittings
available if specified.
YELLOW JACKET Hose Adapters,
Valves, and Parts —
right to the last detail
NEW
Valve core tool page 35
D
EXPANDE
LINE
Quick couplers
page 36
33
1/4" 4-IN-1 BALL VALVE TOOL
for vacuum, charge, cores
and recovery
18971
1. Vacuum valve. Extra 1/4" side
port on 18975 to attach electronic
micron vacuum gauge right at
system for greater accuracy.
2. Core removal access. Lets you
evacuate and charge through an
unrestricted line for increased
speed and higher vacuum.
3. Core replacement.
18975
Remove and replace Schrader cores
without losing charge.
18979
18978
Related product
SuperHeat kits on page 76.
4. Recovery valve. Core removal
allows recovery unit to work at
maximum efficiency, speeding
the recovery process.
UPC #
Description
18975
18971
18980
18978
18979
18997
Vacuum/charge ball valve w/side port
Vacuum/charge valve w/o side port
Accessory set - 2 piece
Schrader rethreading accessory
Broken Schrader remover acc.
Grappler rod/nut assembly
18973
18974
Gasket for 18975 (5 pk.)
Seal Kit includes core, cap,
4 “O”-rings, gasket
5/16" 4-IN-1 BALL VALVE TOOL for R-410A systems
with 5/16" access ports
Similar to the 4-in-1 core tool above
but with 5/16" flare fittings and for use
with R-410A.
18985
18981
UPC #
Description
18985
18981
5/16" vacuum/charge valve-side port
18988
18989
5/16" vacuum/charge valve w/o side port
5/16" rethread accessary
5/16" Schrader rethreader
FULL CONTROL BALL VALVES FOR VACUUM/CHARGING
93846
93834
93836
93844
93830
93840
When building your own charging/
vacuum system, these straight flowthrough valves connect hoses and
provide full-flow capacity. No angles
to cause restrictions and pressure
drops. Handle position shows when
the valve is opened, securely closed
and anywhere between. Use gaskets
on page 37.
M. fl. x M. fl. x M. fl. x “O”M. fl. Fe. fl. 1/4" FPT rings
93838
93848
1/4" SAE*
5/16" SAE
3/8" SAE*
1/2" SAE
Acme 1/2"*
19095
19096
* U.L. Listed
34
COMPACT BALL VALVES
1/4" for full flow
93834 93844
93833
19000
–
93827
–
–
93836 93846
93832
19011
93838 93848
–
19015
93830 93840
93831
19020
Replacement handle/screw for
all 1/4", 3/8" & Acme valves
Replacement handle/screw for
all 1/2" flare valves
Now a smaller ball valve more compact
– still features full flow. Metal valve
handle, add to hoses for charging and
recovery.
• UL recognized assembly to 4000 psi
(276 bar) min. burst, 800 psi (55 bar)
max. working pressure.
UPC #
Description
93844
93843
93842
1/4" compact ball valve – straight
1/4" compact ball valve – 45°
Set of 3 – 45° compact ball valves
5/16" for Special R-410A
Applications
Compact ball valves are available with
5/16" flares for R-410A applications
where 5/16" system ports are used.
• UL recognized assembly to 4000 psi
(276 bar) min. burst, 800 psi (55 bar)
max. working pressure
UPC #
Description
93825
5/16" compact ball valve
5/16" Fe. fl. x 1/4" Male fl.
5/16" compact ball valve
1/4" Fe. fl. x 5/16" Male fl.
93826
93827
5/16" compact ball valve
5/16" Fe. fl. x 5/16" Male fl.
GAS RETENTION
VALVE
Sturdy valve controls refrigerant flow
from access fitting. Closes Schrader
before disconnecting. New back seat
valve feature to retain gas in hose
when disconnecting.
1/4" female fl. x 14" male fl.
UPC #
Description
18993
Gas control valve
18995
“O”- ring set
MODIFIED
NEEDLE VALVE
In-line control.
UPC #
Description
69670
19020
Needle type bleed valve 1/4" flare
Gaskets (10 pkg)
SealRight™ QUICK COUPLERS
19129
19128
19208
19117
19109
19169
19209
19163
19217
UPC #
Description
19109
19208
19209
1/4" SealRight Str. x 1/4" Male fl.
1/4" SealRight 45° x 1/4" Male fl.
1/4" SealRight 90° x 1/4" Male fl.
19100
19117
19217
19128
19129
19169
Set of 19109 and 19209
1/4" SealRight Str. x 3/8" Male fl.
1/4" SealRight 90° x 3/8" Male fl.
1/4" SealRight Str. x 1/8" NPT Female
1/4" SealRight Str. x 1/4" NPT Female
Acme 1/2" SealRight x 1/2" Acme
19163
Acme 1/2" SealRight x 1/4" Male fl.
1
2
3
Pkg. of 10 "O"-rings (1)
Plug assembly with all seals (2)
Nut and clip (3)
Rebuild kit includes #4
Overhaul kit with all above parts
Gasket set
40318
40350
Individual valves are available in two or
three port versions. Nylon seals with
double "O" rings.
UPC #
Description
40317
40318
Hi-side manifold with gauge
Lo-side manifold with gauge & hook
40315
2 port valve – 1/8" NPT Female
x 1/4" Male flare
3 port valve – 1/8" NPT Female
x two 1/4" Male flares
2 port valve - 1/4" QC Female with
CH14 depressor x 1/4" Male flare
with Schrader
40325
40350
VALVE CORE TOOL
Self contained tool for quickly
removing and replacing cores. Handle
contains six cores.
UPC #
Description
19306
Valve core tool
40325
Individual manifolds for high and low
sides of system. Available on page 51.
4
19037
19038
19039
19040
19041
19045
40315
40317
SealRight repair assembly components
3
SINGLE VALVES
QUICK COUPLER-STYLE
BRAZE-IN FITTINGS
Snap-It™ COUPLER
• Snaps on over 1/4" flare
threads with Schrader cores
• Forms tight connection
immediately
• Instantly activates the
Schrader in access fitting
• Instantly shuts off end of hose
when sleeve is pulled back and
coupler pops off access fitting
MANIFOLD PARTICULATE FILTER
• Virtually no
gas release to
atmosphere.
Eliminates
frostbite
• One piece
construction
• For up to 600 psi
UPC #
Description
19090
19094
Snap-it™ Coupler
“O”-ring for coupler (10 pak)
These fittings trap the particles before
they damage valve seats or pass into
your recovery equipment. Replaceable,
cleanable screens.
UPC #
Description
41119
41120
41121
41122
Braze-in brass fitting with replaceable
soft seat. Quick coupler-style fittings
are the same as supplied on metal hose.
UPC#
Description
19082
19083
19084
19085
19086
19087
1/4" str. Fe. fl. w/CH20 gasket
1/4" 45° Fe. fl. w/CH20 gasket
1/4" 90° Fe. fl. w/CH20 gasket
3/8" str. Fe. fl. w/CH11 gasket
3/8" 45° Fe. fl. w/CH11 gasket
3/8" 90° Fe. fl. w/CH11 gasket
19088
1/2" str. only Fe. w/quad ring
Use 19020 (CH20), 19011 (CH11) and 19027
seals (quad ring).
Compact Ball Valve Assemblies
1/4" manifold particulate filter
3/8" manifold particulate filter
UPC#
Description
29001
1/4" yellow ball valve adapter
1/2" manifold particulate filter
Replacement filter screen (5 pak)
29201
1/4" blue ball valve adapter
29601
1/4" red ball valve adapter
35
HOSE ADAPTERS,
VALVES AND PARTS
Innovative SealRight fittings
automatically and immediately trap
refrigerant in the hose when
disconnected, helping meet nonventing regulations and preventing
finger burns. One-piece attaches
quickly, saving up to 50% in time
compared to 2-piece quick couplers.
Works with or without Schrader core.
Gaskets resist deterioration from
CFC, HCFC, HFC refrigerants, and
new oils. Field serviceable. Not
recommended for R-410A systems.
YELLOW JACKET (QC) QUICK COUPLERS – expanded line
YELLOW JACKET QUICK COUPLERS
(Schrader core in male end)
19115
19172
19101
19111
19191
19102
19116
19125
19120
19103
19114
19214
19171
19104
19173
19118
19202
19174
19220
19203
19201
19192
19210
19166
19110
19175
19168
19162
19165
19161
19158
Full size with deep knurling for easy
handling. Special features include
patented CH14 "Adjust-a-Valve"
opener in all 1/4" female ends. Acme
conversion couplers are available for
recovery tank threads and R-134a
cylinder threads.
UPC#
Description
Straight Quick Couplers
UPC#
19220
19201
19202
19203
19214
Description
90° Quick Couplers
3/16" Fe. QC 90° x 1/4" Male fl.
1/4" Female QC 90° x 1/4" Male fl.
1/4" Female QC 90° x 3/8" Male fl.
3/8" Female QC 90° x 3/8" Male fl.
3/8" Female QC 90° x 1/2" Male fl.
Gauge Quick Couplers with CH14
adjustable valve opener
19110
19210
1/4" Female QC x 1/8" NPT Fe.
1/4" Female QC 90° x 1/8" NPT Fe.
19125
19120
19101
19102
19111
19116
19118
1/8" Female QC x 1/4" Male fl. (Ford)
3/16" Female QC x 1/4" Male fl. (GM)
1/4" Female QC x 1/4" Male fl.
1/4" Female QC x 3/8" Male fl.
1/4" Fe. QC Str. x 1/8" NPT Male
1/4" Fe. QC Str. x 1/4" NPT Male
1/4" Fe. QC Str. x 1/4" NPT Female
19103
19104
19115
3/8" Fe. QC x 3/8" Male fl.
3/8" Fe. QC x 1/4" Male fl.
1/2" Female QC x 3/8" Male fl.
19161
1/4" Fe. QC x 1/2" Male Acme
19162
1/4" Fe. hex x 1/2" Male Acme
for permanent applications
19114
3/8" Female QC x 1/2" Male fl.
R-410A couplers – 45° – with schrader valve core
19166
19165
1/2" Acme Male x 1/2" Acme Female
1/2" Acme Female x 1/4" Male fl.
19173
5/16" Fe. QC x 1/4" M. fl. w/Schrader
19168
1/2" Acme Female x 1/8" NPT Male
19174
1/4" Fe. QC x 5/16" M. fl. w/Schrader
19158
1/2" Acme Female x 14 mm Male
5/16" Quick Couplers with CH14
adjustable valve opener
19121
19221
5/16" QC Str. x 1/4" Male fl.
5/16" QC 90° x 1/4" Male fl.
19122
1/4" QC Str. x 5/16" Male fl.
19222
1/4" QC 90° x 5/16" Male fl.
ACME 1/2" Couplers – Auto Straight
All couplers have Schrader valve cores
in male flare end. Female coupler end
has deep knurling for easy handling.
Patented CH14 "Adjust-a-Valve"
Opener in all 1/4" female ends.
UPC#
Description
Straight Quick Couplers
19171
19172
1/4" Female QC x 1/4" Male fl.
3/8" Female QC x 1/4" Male fl.
90° Bend Quick Couplers
19191
1/4" Female QC x 1/4" Male fl.
19192
3/8" Female QC x 1/4" Male fl.
R-410A couplers – 45° – with schrader valve core
19173
19174
5/16" Fe. QC x 1/4" M. fl. w/Schrader
1/4" Fe. QC x 5/16" M. fl. w/Schrader
19175
5/16" Female QC x 5/16" Male fl.
YELLOW JACKET
ADJUST-A-VALVE OPENERS
™
(OLD)
CH14
High volume
flow pattern
125 AND 145 LB. CYLINDER
VALVE ADAPTER
Finger tight adapters fit 125
and 145 lb. cylinders. Seal
remains seated. Two sizes.
ADD-A-HOSE COUPLERS UNIONS
Add-a-hose couplers
easily connect hoses
to the length desired.
36
UPC#
Description
19105
3/4" NPS finger tight cylinder
adapter with 1/4" Male flare
19106
3/4" NPS finger tight cylinder
adapter with 3/8" Male flare
18001
Replacement gasket (10 pak)
UPC # Male flare
19143
19144
19146
19148
3/16"
1/4"
3/8"
1/2"
CH75
(CURRENT)
The patented "Adjust-a-Valve" opens
out of tolerance Schrader valves in
1/4", 3/16" and 5/16" couplers. Simply
rotate the opener with needle nose
pliers to the desired height. When
finished, rotate back. (Pat. No. 3592439).
“Adjust-a-Valve” for 1/4" and 5/16"
hoses is the same.
UPC # Male flare
19150
19152
19142
–
5/8"
3/4"
Acme 1/2"
–
UPC # Part
Description
19302
19301
CH14
CH75
Adjust-a-Valve openers (10)
1/4" valve openers (10)
19304
—
1/8" valve openers (10)
YELLOW JACKET LIQUID CHARGING ADAPTER
(Convert liquid to saturated vapor)
Liquid
charging is
recommended
when charging
blends into
refrigeration
and air conditioning
systems. Since compressors
cannot compress liquids you need a
liquid charger adapter for safe and fast
liquid (saturated vapor) charging
through the low pressure side of a
system. The YELLOW JACKET adapter
connects to the cylinder valve or
refrigerant can.
19021
19005
19011
19015
Gasket/ Qty.
Part
Application
19020
CH20/10
1/4" hose
5/16" hose
1/2" Acme hose
1/4" hose
3/8" hose
1/2"-5/8" hose
3/4" hose
Cylinder Valve
1/8" Coupler
19010
CH20 and
CH14
6
3
UPC#
“O”-ring Qty.
19025*
19026*
19027*
19034
–
–
–
–
10
10
10
10
19037
–
10
19094
–
10
• Refrigerant flashes off into a
saturated vapor to speed entry
• Eliminates the time and work of
heating cylinders
• Blue color-coded aluminum.
UPC#
UPC#
Description
19130
3/8" Fe. fl. x 1/4" M. fl. adapter
19131
1/2" Fe. fl. x 3/8" M. fl. adapter
19132
1/2" Fe. fl. x 1/4" M. fl. adapter
19160
19133
1/2" Fe. fl. x 1/2" M. Acme adapter
3/8" Fe. fl. x 1/2" M. fl. adapter
Description
41123
1/4" liquid charging adapter
41124
5/16" liquid charging adapter
41132
41138
Repl. “O”-ring/orifice for 1/4" adapter
Repl. “O”-ring/orifice for 5/16" adapter
18001
UPC#
19005 CH20/100 100
19011
CH11
10
19015
CH80
10
19012
E hose
10
18001**
10
19021
3/16"
10
Gasket
19022
–
• To protect the compressor, adapter
orifice reduces liquid flow to a level
below compressor capacity
VACUUM PUMP ADAPTER
PARTS KITS & EMPTY BOXES
The only gaskets designed for
optimum performance with YELLOW
JACKET® Charging Hoses. Works with
all refrigerants. Manufactured to strict
tolerances to resist blow out.
10
Reducing adapters
for pump intakes on
SuperEvac™ and
other vacuum pumps.
5 For 60667
recovery pliers
1/4" hose
opener
Application
1/4" "O"-ring
3/8" "O"-ring
1/2" "O"-ring
"O"-ring for 14 mm
Male
1/4" SealRight
"O"-ring
Snap-It "O"-rings
Convert a 3/8" or 1/2" vacuum pump
intake into 1/4" R-12 and 1/2" Acme
R-134a compatible fittings.
19003 COMPLETE KIT includes
following gaskets, valve openers and
SealRight parts in a 12 compartment
case.
•
•
•
•
•
•
•
•
•
•
•
Five 1/8" gaskets
Five 1/8" valve openers
100 3/16"–1/4" gaskets
Ten 1/4" adjustable
CH14 valve openers
Ten 1/4" CH75 flat valve openers
Ten 3/8" CH11 gaskets
Ten 1/2"–5/8" CH80 gaskets
Ten cylinder valve flat gaskets
Ten SealRight “O”-rings
Four SealRight plug and
seal assemblies
Four 1/4" SealRight nut and clip
EMPTY PARTS BOXES
Description
1/2" pump adapter with 1/4" flare
and 1/2" Acme Male fittings
3/8" pump adapter with 1/4" flare
and 1/2" Acme Male fittings
36019
WRAP-AROUND HEATER
FOR REFRIGERANT CYLINDER
6' Cord
20" Velcro
Straps
Fits 30/50-125 lb cylinders. Thermostat
controlled with maximum 130˚F (54°C)
and minimum 120˚F (48.8°C) (surface
temperature of tank). Cycles on/off to
maintain surface temperature. 200 watt,
115V or 230V; 20" velcro straps; 6' cord.
UPC#
Size
59651
59652
59653
59654
59655
19004
11" x 6-3/4"
x 3/4"
11" x 6-3/4"
x 3/4"
Kit box with
parts label
6 compartments
empty
60178
11" x 6-3/4"
x 3/4"
12 compartments
empty
UPC#
Description
60135
11" x 6-3/4"
x 3/4"
18 compartments
empty
68848
68849
Wrap-around cylinder heater 115V
Wrap-around cylinder heater 230V
Copper gaskets (10 pak)
Copper gaskets (10 pak)
Copper gaskets (10 pak)
Copper gaskets (10 pak)
Copper gaskets (10 pak)
* Gaskets for some metal hose sizes.
Others use 19020 or 19011 gaskets.
** Flat washer.
60177
Description
UPC#
36018
UPC# Size Description
1/4"
3/8"
1/2"
5/8"
3/4"
HOSE ADAPTERS,
VALVES AND PARTS
QUICK COUPLER GASKETS
&”O”-RINGS
VACUUM PUMP INTAKE ADAPTER
37
AUTOMOTIVE R-134a
A/C COUPLERS – premium
with control valve
• Highest flow characteristics.
• Low profile for tight applications.
Couplers interface with R-134a service
ports. 14 mm female thread or 1/4"
male flare available.
• Quick, easy connect/disconnect.
• Control valve for access to systems
even at working pressures.
• Integral safety sleeve holds
coupler securely to service port.
AUTOMOTIVE R-134a A/C COUPLERS – ECONOMY
A basic R-134a service coupler with no
control valve. Snaps on for instant flow.
Professionals should use couplers above.
41317
41318
AUTOMOTIVE A/C FITTINGS
COUPLERS
19166
19158
19165
19168
19162
40265
19163
19169
19142
19161
Adapter fitting designed to work with
1/2" Acme or 14 mm threads.
UPC #
Description
41318
Lo side coupler w/ 1/4" flare
41317
Hi side coupler w/ 1/4" flare
41305
Replacement “O”-ring set (6 pc.)
UPC #
Description
19157
19156
19161
19165
19158
19162
19168
19169
14 mm M. x 1/4" Male fl.
14 mm M. x 3/8" Male fl.
1/2" Acme M. x 1/4" Fe. fl.
1/2" Acme Fe. x 1/4" Male fl.
1/2" Acme Fe. x 14 mm Male
1/2" Acme M. x 1/4" Fe. fl. Hex
1/2" Acme Fe. x 1/8" Male pipe
1/2" Acme M. x 1/2" Acme
SealRight™
1/2" Acme SealRight x 1/4" M. fl.
1/2" Acme Fe. x 1/2" Acme Male
1/2" Acme M. x 1/8" NPT Male Half Union
1/2" Acme Union
1/2" Acme Fe. Hex x 13 mm R-134a
low side Male for A/C system
not shown
19163
19166
40265
19142
19153
UPC #
Description
40311
40312
40321
40322
40313
40314
40323
40324
40347
40348
40316
14 mm Fe, str. high side auto coupler
14 mm Fe, str. low side auto coupler
14 mm Fe, 90° high side auto coupler
14 mm Fe, 90° low side auto coupler
1/4 M. Fl., str. high side auto coupler
1/4 M. Fl., str. low side auto coupler
1/4 M. Fl., 90° high side auto coupler
1/4 M. Fl., 90° low side auto coupler
High side x 3/8" Male flare auto coupler
Low side x 3/8" Male flare auto coupler
Replacement “O”-rings (2 pak)
AUTOMOTIVE R-134a 3-IN-1
VACUUM/CHARGE RECOVER
CORE TOOL
High-Side
Low-Side
1. Core removal for vacuum and
charges. Lets you evacuate and charge
through an unrestricted line for
increased speed and higher vacuum.
3. Core replacement.
4. Recovery valve. Core removal allows
recovery unit to work at maximum
efficiency, speeding the recovery
process.
UPC # Description
18962
18961
Low-side R-134a auto valve core tool
High-side R-134a auto valve core tool
41300
“O”-ring kit for above
SAFETY GOGGLES
AUTOMOTIVE R-134a and R-12 CAN TAPS
With side tap, handles slip around and
close to pierce the can. Small inserts
for use with lubricant cans.
Check valve on side taps help prevent
back pressure into can.
Not for use with other refrigerants.
38
UPC #
Description
36192
36193
36194
R-134a side can tap
R-12 side can tap
Gaskets for side can tap (10 pak)
Helps protect your eyes against metal
particles, sparks, refrigerant gases,
etc. when working on HVAC&R
systems.
Safety goggles are recommended any
time you work on a system.
UPC#
Description
11002
Safety goggles
11003
Ventilated safety goggles
YELLOW JACKET Charging Systems –
for just the right
measure of refrigerant
NEW
BRUTE II ™ Manifold page 43
NEW
Digital Refrigerant Analyzer
page 42
39
YELLOW JACKET Charging Systems – technology and
tools to accurately measure and conserve refrigerant.
With too little or too much refrigerant,
systems run inefficiently, using more
electricity than necessary. And now
with the soaring cost of refrigerant,
energy, and labor, accurate
measurement is more important than
ever. That’s why YELLOW JACKET®
Charging Manifolds and gauges are
carefully assembled and fully
inspected for accuracy in all of
these jobs:
• Check system pressure
• Charge vapor refrigerant into
systems
• Charge liquid refrigerant into
high side
• Purge condenser
• Charge oil into compressor
• Pull vacuum
• Test for leaks
• Set controls
Certified Gauges for your
confidence and convenience
• Easy compliance with a
quality policy
You make decisions
based on what your
gauge is telling
you. Now you
can have greater
confidence in your
measurements and
decisions with a line of certified
YELLOW JACKET Class I Replacement
Manifold Gauges and Manifolds with
Class I gauges.
Certified gauges help achieve and
prove the level of quality that your
employer or customer expects.
YELLOW JACKET gauges have always
been manufactured and calibrated to
NIST standards (National Institute of
Standards and Technology). The
standard Ritchie procedure has been
to measure for accuracy at five points:
two times – up the scale and then back
down. Many manufacturers measure at
only three points (A, B, C)
• Simultaneously connect to high
and low sides, vacuum pump and
recovery unit or refrigerant tank
• Diagnose, evacuate, and charge
without switching hoses
Feel confident even if you are
servicing critical applications such as
ice machines or other equipment with
precise charging requirements.
• Convenient documentation to help
meet ISO requirements
2-1/2” Brass Manifold Gauge
with Class 1 Accuracy
4” Manifold
Gauge with Class 1
Accuracy
3-1/8” Manifold Gauge
with Class 1 Accuracy
From the full line of YELLOW JACKET®
2- and 4-Valve Charging Systems you
can find just what you need for your
business and budget. And all are built
to last.
With either models you have full
capabilities for every application.
4-valve models add a fourth hose and
the following capabilities for increased
efficiency and speed.
• Accuracy assurance
A calibration certificate accompanies each
Calibrated Gauge and the back of each
Certified Gauge is clearly identified with a label
applied by the certifying Ritchie technician.
Calibration Certificate Information
Now, the Ritchie certification
process documents the NIST
calibration plus compliance to ANSI
Z540.1 and ISO 10012 standards.
The certification is good for one
year and then recalibration is
recommended. Serialized, dated
certificates are packed with each
certified unit.
Certification benefits:
• Convenience and time savings
In the past when you wanted
certification, you had to purchase the
gauge at one location and then take it
to a calibration house. Now you save
the time of the second step.
The certificate packed with each
certified gauge provides evidence of
calibration standards traceable to
NIST and includes a serial number
that matches the serial number on the
gauge. Ritchie Engineering maintains
records of each sale as a back up to
your records.
A calibration certificate contains
information for necessary traceability.
The following YELLOW JACKET
Manifolds include certified gauges:
Series 41 Manifolds 49271, 49272
TITAN™ Manifolds 49281, 49282,
49283
BRUTE II™ Manifolds 49291, 49292
40
Selection Guide for °F and °F/C (see page 52 for metric)
Range of performance for your business and budget
Choice of
brass or
forged
aluminum
alloy
Choice of
analog
or digital
gauges
A pattern
of ongoing
innovation
Reliability
and durability
across the line
Series 41
Page
UPC#
R-12, R-22,
R-134a
41842
41846
R-12, R-22,
R-502
41212
41213
41214
41232
41233
41235
41215
42233
42235
43213
43214
43215
43219
43220
43233
43235
44213
44214
44215
44219
44220
44233 47,
44235 48
45213
45214
45215
45219
45220
R-134a
49282
49801
49802
49805
45
49847
45
49902
49905
49922
49925
44
46020
46021
46022
46026
46080
46081
46082
46084
49292
43
R-22, R-134a,
R-404A
42005
42006
49272
48
49883
49887
49889
45
49983
49987
49993
49997
44
46040
46041
46042
46043
46048
46090
46091
46092
46094
43
R-22, R-404A,
R-410A
42001
42004
49271
48
49281
49863
49867
49868
45
49283 49968
49963 49973
49967 49977
44
46010 46013
46011 49291
43
49831
49832
49835
45
49932 49952
49935 49955
44
46030 46032
46031 46038
43
49860
49862
49865
45
49960 49965
49962 49982
44
46000
46001
46003
43
R-134a, R-404A,
R-407C
R-134a, R-404A, 41311 42010 42435 44311 45314
41312 42011 42436 44313 45315
R-507
41313
41314
41315
41319
41372
R-410A
42313
42315
42332
42333
42335
43311
43313
43314
43315
43319
41703 41711 42030
41709 41712 42715
41710 41715
Digital Analyzer
Page
UPC#
48
42007
41219
41220
42000
42020
42213
42215
42219
TITAN™ 2-valve
TITAN™ 4-valve
BRUTE II™ 4-valve
Page
Page
Page
UPC#
UPC#
UPC#
40802,
40805
42
47,
48
44314 45319
44315
44319
45311
45313
47
For metric see page 52.
41
CHARGING
SYSTEMS
Refrigerant
YELLOW JACKET DIGITAL REFRIGERATION SYSTEM ANALYZER
with system modulation bar graph for fast, accurate diagnostics
For time-saving diagnostics, the
easy-to-read pressure bar graphs of this
patented unit quickly tell you more than
you could ever see with the vibrating
needle of a typical pressure gauge. You
see pressure dynamics to readily know if
the system’s thermostatic expansion
valve is modulating properly, if liquid is
flooding back into the systems, and
more. Saturation, subcooling, and
superheat readings are automatic to
eliminate fishing in your wallet for
reference cards. This almost immediate
knowledge of system behavior and
faults can help save up to 10 minutes
and more on many jobs.
Rubber boot protects
instrument from minor
bumps and impacts.
• Rugged case construction with
rubber boot to tolerate impact and
resist typical oils, acids, and sunlight
Easy to Use:
• Bar graph segments shows changes
from digital reading (range of ±2
psi on low-side, ±8 psi on high-side)
• Integrated temperature probe for
automatic superheat and subcooling
readings
• Max and min pressure monitoring
for control set-up
• Auto zero key to eliminate manual
recalibration
• Vacuum detection inHg
• Easy-to-read LCD screen with large
3/8" digits
• Temperature, superheat or
subcooling shown on lower right
(eg. 14°F superheat)
Automatically
calibrates to
current
atmospheric
pressure
Changes the
digits update
rate
Changes
contrast
Resets
peak pressure
memory
Specifications:
• Profiles 22 common refrigerants:
R-12
R-404A
R-416A
R-22
R-406A
R-417A
R-134a
R-407C
R-420A
R-290
R-408A
R-502
R-401A
R-409A
R-507
R-401B
R-410A
R-508B
R-402A
R-414B
R-600A
R-402B
(Upgradeable for new refrigerants)
• Temperature in middle is
corresponding bubble and dew
points for current pressures
Selects
active
refrigerant
Changes
between
traditional (psi,
"Hg,°F) and
international
system of units
(kPa, bar, °C)
Features:
• Digital readings show resolution of
1/4 psi on low side, 1 psi on high side
Pressure accuracy:
0.5% F.S. ± 1 least significant
digit, calibration traceable to NIST
Pressure ports:
Two 1/8" acting as low and
high side gauges
Working pressure:
Low side: 0-200 psi (1350 kPa,
13.5 bar)
High side: 0-550 psi (3790 kPa,
37.9 bar)
Proof pressure:
Low side: 600 psi (4100 kPa,
41 bar)
High side: 1500 psi (10300 kPa,
103 bar)
Burst pressure:
Low side: 2000 psi (13500 kPa,
135 bar)
High side: 5000 psi (34500 kPa,
345 bar)
Temperature sensor range:
-40° to 250°F (-40° to 125°C)
Selects temperature,
superheat, subcooling,
max/min pressure
Temperature accuracy:
±0.9°F (±0.5°C) between 32° to
158°F (0° to 70°C)
Usage environment:
Indoor/Outdoor dew, splash and
rain resistant; do not immerse
in water
Storage and operational temperature:
-4° to 122°F (-20° to 50°C)
Power supply:
4 AA Batteries (approx. 6 months
under normal use)
Weight:
1.6 lb. (.725 kg)
Dimensions:
6.7 x 4.8 x 2.5" (17 x 12.2 x 6.4 cm)
UPC # Description
40801
40802
40805
41067
41068
R-410A adapter kit – 1/4" to 5/16" service fitting
Digital analyzer on TITAN™ 4-valve manifold
40802 with 1/4" x 60" RYB and
3/8" x 60" yellow PLUS II™ hoses
Temperature Probe
Extended Manifold Hook
41069
Rubber Boot
Replacement parts for manifold on page 46.
42
YELLOW JACKET BRUTE II™ 4-Valve Test & Charging Manifold - °F
Forged aluminum alloy body with
full 3/8" bore for faster vacuum
and charging
Large, easy-to-read
3-1/8" (80 mm)
red and blue
steel case
The new BRUTE II™ 4-Valve Test and
Charging Manifold has been trimmed
down for lighter weight but with the
same powerful performance of the
original model. This streamlined unit
continues to provide the flow that's
proven faster than any conventional
manifold. And even though sleeker and
more compact, the aluminum alloy is
forged for strength and reliability with
3/8" bores through the body to speed
the job.
1% accuracy
(Class 1) gauges
with protective boots;
Other Features and Benefits:
• Fourth hose enables connection to
hi/lo sides, refrigerant tank, and
recovery unit or vacuum pump for
diagnostics, evacuation and charging
without switching hoses
– 1/4" hi/lo sides with 3/8" vacuum
port for regular jobs, or;
New
UPC#
• Contoured easy-grip handles for
positive control; color coded for
ready identification
R-410A
R-22, R -134a R- 404A
• Exclusive 100-mesh filter in-line
on all flare fittings helps keep out
particulate material and extend
the life of the seat
R- 134a
R- 404A
R- 407C
R-12, R-22, R- 502,
• Proven, double “O”-ring piston for
reliability and long service life
R-22
R- 404A
R- 410A
• Front access for easy field
recalibration
• Sight glass to easily view
refrigerant movement and condition
during charging and recovery
• Heavy-duty hook won’t pull out
• Also available with YELLOW JACKET®
3-1/8" (80 mm) red and blue liquidfilled gauges
For metric see page 54.
For replacement parts see page 46.
*
Hoses
BRUTE II 4-VALVE with 3/8” Vacuum Port
46000 3/8" 1/4"
Red/Blue Manifold Only
46001 3/8" 1/4”" Liquid
Manifold Only
46003 3/8" 1/4"
Red/Blue 60" PLUS II™ Compact Ball Valve - RYB & 3/8" x 45°
46010 3/8" 1/4"
Red/Blue Manifold Only
49291* 3/8" 1/4"
Red/Blue Manifold Only
46011 3/8" 1/4"
Liquid
Manifold Only
46013 3/8" 1/4"
Red/Blue 60" PLUS II™ Compact Ball Valve - RYB & 3/8" x 45°
46020 3/8" 1/4"
Red/Blue Manifold Only
49292* 3/8" 1/4"
Red/Blue Manifold Only
46021 3/8" 1/4"
Liquid
Manifold Only
46022 3/8" 1/4"
Red/Blue 60" PLUS II™ RYB & 3/8" x 45°
46026 3/8" 1/4"
Liquid
72" PLUS II™ RYB & 3/8" x 45°
BRUTE II 4-VALVE COMMERCIAL with increased capacity—larger ports
46080 3/8" 3/8"
Red/Blue Manifold Only
46081 1/2" 3/8"
Liquid
Manifold Only
46082 3/8" 3/8"
Red/Blue 4 @ 3/8" x 60” Heavy Duty - Str. x 45°
46084 1/2" 3/8"
Liquid
3 @ 3/8" x 60” Heavy Duty - Str. x 45°
1 @ 1/2" x 60” Heavy Duty - Str. x Str.
BRUTE II 4-VALVE with 3/8” Vacuum Port
46030 3/8" 1/4"
Red/Blue Manifold Only
46031 3/8" 1/4"
Liquid
Manifold Only
46032 3/8" 1/4"
Red/Blue 60" PLUS II™ RYB & 3/8" x 45°
46038 3/8" 1/4"
Liquid
72" PLUS II™ RYB & 3/8" x 45°
BRUTE II 4-VALVE with 3/8” Vacuum Port
46040 3/8" 1/4"
Red/Blue Manifold Only
46041 3/8" 1/4"
Liquid
Manifold Only
46042 3/8" 1/4"
Red/Blue 60" PLUS II™ RYB & 3/8" x 45°
46043 3/8" 1/4"
Red/Blue 60" PLUS II™ Compact Ball Valve - RYB & 3/8" x 45°
46048 3/8" 1/4"
Liquid
72" PLUS II™ RYB & 3/8" x 45°
BRUTE II 4-VALVE COMMERCIAL with increased capacity—larger ports
46090 3/8" 3/8"
Red/Blue Manifold Only
46091 1/2" 3/8"
Liquid
Manifold Only
46092 3/8" 3/8"
Red/Blue 4 @ 3/8" x 60" Heavy Duty - Str. x 45°
46094 1/2" 3/8"
Liquid
3 @ 3/8" x 60" Heavy Duty - Str. x 45°
1 @ 1/2" x 60" Heavy Duty - Str. x Str.
Manifold comes standard with certified gauges. For more information on the
certification of 3-1/8" gauges, see page 40.
Discontinued
BRUTE UPC #
CHARGING
SYSTEMS
– 3/8" hi/lo sides with 1/2" vacuum
port for larger systems
Vac. Hi, Lo Gauge
Port Charge
47722
46822
n/a
n/a
n/a
n/a
n/a
n/a
46422
46812
n/a
48819
n/a
46903
n/a
46907
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
43
YELLOW JACKET TITAN™ 4-Valve Test & Charging Manifold - °F
Forged aluminum alloy body
for increased strength and reliability
The new TITAN ™ Test and Charging
Manifold is the first forged aluminum
manifold in the industry. Special
aluminum alloy body makes this unit
lightweight for handling ease with the
durability and reliability required for
repeated, rugged use.
Features/Benefits
• Large, easy-to-read 3-1/8" (80 mm)
steel case red and blue, 1% accuracy
(Class 1) gauges; front access for
easy field recalibration; optional
protective gauge boots available
• Proven, double “O”-ring piston for
reliability and long service life
Contoured
easy-grip handles
for positive control;
color coded
for ready
identification
• Exclusive 100 mesh filter in-line on
all flare fittings helps keep out
particulate material and extend the
life of the seats
R-410A
• Sight glass to easily view
refrigerant movement and condition
during charging and recovery
• Heavy duty hook won’t pull out
• Also available with YELLOW JACKET®
3-1/8" (80 mm) red and blue
liquid-filled gauges
For metric see page 55.
For replacement parts see page 46.
44
R-12
R-22
R-502
R-134a
R-404A
R-407C
• 3/8" vacuum port for use with
larger hose to cut evacuation time
by up to 33% (all other fittings on
unit are 1/4")
R-22
R-134a
R-404A
• Fourth hose to enable connection
to hi/lo sides, refrigerant tank, and
recovery unit or vacuum pump for
diagnostics, evacuation and charging
without switching hoses
R-22
R-404A
R-410A
4-Valve Features/Benefits
*
UPC#
Gauges
Hoses
49962
49982
49960
49965
49963
49283*
49967
49968
49973
49977
49902
49905
49922
49925
49932
49935
49952
49955
49983
49987
49993
49997
Red/Blue
Liquid
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Liquid
Liquid
Red/Blue
Red/Blue
Liquid
Liquid
Red/Blue
Red/Blue
Liquid
Liquid
Red/Blue
Red/Blue
Liquid
Liquid
No hose
No hose
60" PLUS II™ Compact Ball Valve - RYB & 3/8" x 45°
60" PLUS II™ - RYB & 3/8" x 45°
No hose
No hose
60" PLUS II™ - RYB & 3/8" x 45°
60" PLUS II™ Compact Ball Valve - RYB & 3/8" x 45°
No hose
60" PLUS II™ - RYB & 3/8" x 45°
No hose
60" PLUS II™ - RYB & 3/8" x 45°
No hose
60” PLUS II™ - RYB & 3/8" x 45°
No hose
60" PLUS II™ - RYB & 3/8" x 45°
No hose
60" PLUS II™ - RYB & 3/8" x 45°
No hose
60" PLUS II™ - RYB & 3/8" x 45°
No hose
60" PLUS II™ - RYB & 3/8" x 45°
Replaces Bantam#
Manifold comes standard with certified gauges. For more information on the
certification of 3-1/8" gauges, see page 40.
45962
45982
45960
45965
n/a
n/a
n/a
n/a
n/a
n/a
45902
45905
45922
45925
45932
45935
45952
45955
n/a
n/a
n/a
n/a
YELLOW JACKET TITAN™ 2-Valve Test & Charging Manifold - °F
Forged aluminum alloy body
and large easy-to-read gauges
The new TITAN™ Test and Charging
Manifold is the first forged aluminum
manifold in the industry. The special
aluminum alloy construction of the
manifold body makes this unit
lightweight for handling ease with the
durability and reliability required for
repeated, rugged use.
Features/Benefits
• Large, easy-to-read 3-1/8" (80 mm)
steel case red and blue, 1% accuracy
(Class 1) gauges; front access for
easy field recalibration; optional
protective gauge boots available
• Proven, double “O”-ring piston for
reliability and long service life
• Exclusive 100 mesh filter in-line on
all flare fittings helps keep out
particulate material and extend the
life of the seats
R-410A
R- 22
R- 404A
R- 410A
• Sight glass to easily view
refrigerant movement and condition
during charging and recovery
R- 22 R- 134a
R- 134a R- 404A
R- 404A R- 407C
R- 12
R- 22
R- 502
• Heavy duty hook won’t pull out
For metric see page 56.
For replacement parts see page 46.
R- 134a
*
New
UPC#
Gauges
Hoses
Discontinued
Bantam UPC #
49862
49865
49860
49863
49281*
49867
49868
49802
49282*
49805
49801
49832
49835
49831
49883
49887
49889
49847
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
Red/Blue
No hose
60" PLUS II™ - RYB
60” PLUS II™ Compact Ball Valve - RYB
No hose
No hose
60" PLUS II™ - RYB
60" PLUS II™ Compact Ball Valve - RYB
No hose
No hose
60" PLUS II™ - RYB
60" PLUS II™ SealRight™ - RYB
No hose
60" PLUS II™ - RYB
60" PLUS II™ SealRight™ - RYB
No hose
60" PLUS II™ - RYB
60" PLUS II™ SealRight™ - RYB
72" PLUS II™ Acme fittings - RYB
45862
45865
45860
n/a
n/a
n/a
n/a
45802
45802
45805
45754
45832
45835
45774
n/a
n/a
n/a
n/a
Manifold comes standard with certified gauges. For more information on the
certification of 3-1/8" gauges, see page 40.
PROTECTIVE GAUGE BOOTS for 2-1/2" and 3-1/8" gauges
Rubber boots slip easily around gauges to
cushion and protect them from impact.
• Fit 2-1/2" and 3-1/8" gauges
without covering easy access
recalibration screw
• Color-coded red or blue to match gauge
UPC #
Size
Description
49090
49091
49092
49190
49191
49192
2-1/2"
2-1/2"
2-1/2"
3-1/8"
3-1/8"
3-1/8"
Set of gauge boots
Red protective gauge boot
Blue protective gauge boot
Set of gauge boots
Red protective gauge boot
Blue protective gauge boot
45
CHARGING
SYSTEMS
• Contoured easy-grip handles for
positive control; color coded for
ready identification
BRUTE II™ MANIFOLD REPLACEMENT PARTS
40279: Hanging hook
49192:
Blue boot
41045: Sight glass
41046: Sight glass retainer
41047: Gaskets (2)
49191:
Red boot
49190: Set of red
and blue boots
REPLACEMENT GAUGES:
Starting on page 60
41113: 3/8" MFL
41116: 4 pistons, x 1/8" NPT Male
fitting
4 replacement
screens
40271: 1/4" MFL
x 1/8" NPT Male
fitting
41106: 41103: Piston
41090:
Feed
Handle 41092: 41096:
Retaining screw assembly
screw Blue
handle nut
(2)
with screw
41117: Filter (4)
41130: 1/4"
MFL x 1/4"
NPT Male
fitting
41139: 3/8"
MFL x 1/4"
NPT Male
fitting
41091:
Yellow
handle
with
screw
41094:
Red handle
with screw
41091:
Yellow
handle
with
screw
TITAN™ MANIFOLD REPLACEMENT PARTS
REPLACEMENT GAUGES:
Starting on page 60
41045: Sight glass
41046: Sight glass retainer
41047: Gaskets (2)
40279: Hanging hook
41113:
3/8" MFLx
1/8" NPT
Male fitting
41142:
Handle
screw
(2)
41135:
41134:
Retaining Feed
nut
screw
40271: 1/4"
MFL x 1/8"
NPT Male
fitting
41133:
Piston
assembly
41044:
Red handle
with screw
41041: Yellow handle with screw
41042:
Blue handle
with
screw
41139: 3/8" MFL x 1/4"
NPT Male fitting
46
41041:
Yellow handle
with screw
41063: Filter
40270: 1/4" MFL x
1/8" NPT Male fitting
YELLOW JACKET SERIES 41
MANIFOLDS with 2-1/2" gauges
Heavy-duty
swivel hook.
Flutterless ™ Technology. Surge
protector and silicone dampened
movement helps minimize needle
pulsation for
easier, more
accurate
readings.
Forged brass body with metal valve
handles. Forged body is solid
brass for durability. Full
porting maximizes capacity.
Metal valve handles are
full size for easy operation.
Hose anchors are forged
into back of body at 45°.
Flutterless
Standard
Sliding double "O"-ring pistons.
Non-rotating design reduces wear.
Only 1-1/2 turns give you full flow.
Long-life nylon seat is also for vacuum
and R-134a, R-404A, R-507, R-407C,
R-410A, etc.
Pretested. Every
manifold is individually
tested for reliability
before shipping.
Limited Lifetime
Warranty on manifold bar
and valves – not gauges. See
manifold instructions for details.
YELLOW JACKET Hoses. Most manifolds
include color-coded YELLOW JACKET
charging hoses.
Easy-to-read 2-1/2" steel case gauges
(°F) with 3-2-3% accuracy.
Manifold with original HA hose
Manifold with PLUS II with standard fittings
Manifold with PLUS II with SealRight™ fittings
Manifold with PLUS II with FlexFlow™ fittings
Manifold with PLUS II with compact ball valve
NOTES: Manifolds with some other hose
combinations available.
* Special R-410A hose – R&B hose is
1/4" x 45° 5/16" end; Y hose is
1/4" x 45° 1/4" end.
See page 57 for R-410A manifolds with
5/16" hose holder fittings.
Description
R-12, R-22, R-502
Basic unit: manifold,
gauges, hook and anchors
36" RYB hoses
R-134a, R-404A, R-507
R-410A
SERIES 41 MANIFOLDS with
2-1/2" gauges (no hose)
Refrigerants
R-12, R-22, R-502
R-134a, R-404A, R-507
R-410A
Display
package
No
hose
1
2
3
4
5
41212
—
—
—
—
—
—
41213 43213 44213 45213 42213
48" RYB hoses
60" RYB hoses
72" RYB hoses
—
—
—
41220 43220 44220 45220
—
41215 43215 44215 45215 42215
41219 43219 44219 45219 42219
36" RYB hoses and case
Basic unit: manifold,
gauges, hook and anchors
36" RYB hoses
—
41214 43214 44214 45214
41312
—
—
—
—
—
—
—
41313 43313 44313 45313 42313
—
—
—
—
41311
41315
41319
41314
43311
43315
43319
43314
44311
44315
44319
44314
41712
—
—
—
60" RYB hoses
—
—
41709
—
60" RYB hoses special*
HCA 60" hose
—
—
—
—
41715
41710
—
—
48" RYB hoses
60" RYB hoses
72" RYB hoses
36" RYB hoses and case
Basic unit: manifold,
gauges, hook and anchors
CHARGING
SYSTEMS
1
2
3
4
5
Refrigerants
45311
—
45315 42315
45319
—
45314
—
—
—
41703 42715
—
—
UPC#
Description
Packaging
41212
42000
Red & blue gauges
Red & blue gauges
Boxed
Clamshell
41232
42020
41312
42010
41372
42011
41712
Brass gauges
Brass gauges
Red & blue gauges
Red & blue gauges
Brass gauges
Brass gauges
Red & blue gauges
Boxed
Clamshell
Boxed
Clamshell
Boxed
Clamshell
Boxed
42030
Red & blue gauges
Clamshell
41711
—
47
YELLOW JACKET SERIES 41 MANIFOLDS with 3-1/8" gauges
• Long life nylon seats.
• Forged brass body for durability.
• Full porting maximizes capacity
and flow.
• Some models include color-coded,
60" PLUS II™ hoses with standard
1/4" flare fittings.
• Hose assemblies UL recognized for
4000 psi (275 bar) burst and 800
psi (55 bar) working pressure.
File# SA9737.
Features
• Wide choice of refrigerant
combinations including:
• R-22, R-134a, R-404A
• R-12, R-22, R-134a
• R-22, R-404A, R-410A
• Color-coded scales with bold, easy
to read dials.
• Dials with 1% accuracy (Class 1)
for critical charge systems.
• Proven sliding double “O”-ring
pistons reduce wear.
This field-proven manifold line has now
been expanded to include larger, easier
to read 3-1/8" color-coded gauges in
rugged steel cases with polycarbonate
crystals.
Most importantly, these gauges feature
1% accuracy for an exact reading in
critical charge systems.
Refrigerants
UPC#
Gauge
RYB Hose
R-12, R-22, R-134A
41842
42007
41846
42001
3-1/8" Red/Blue
3-1/8" Red/Blue
3-1/8" Red/Blue
3-1/8" Red/Blue
3-1/8" Red/Blue
3-1/8" Red/Blue
3-1/8" Red/Blue
3-1/8" Red/Blue
3-1/8" Red/Blue
None
60" PLUS II™ standard fittings
72" PLUS II™ with couplers
None
None
60" PLUS II™ standard fittings
None
None
60" PLUS II™ standard fittings
R-22, R-404A, R-410A
R-22, R-134a, R-404A
*
49271
*
42004
42005
49272
*
42006
Manifold comes standard with certified gauges. For more information on the
certification of 3-1/8" gauges, see page 40.
SERIES 41 DELUXE MANIFOLDS – Class 1 (1% accuracy) brass gauges
What makes YELLOW JACKET®
brass gauges superior?
1% accuracy
YELLOW JACKET is the only U.S.-made
manifold to incorporate all the
following important features into a
truly premium gauge.
1. Upgraded movement with phosphor
bronze plates, stainless gears and
pinions. Dissimilar parts create less
friction and last longer. FlutterLess™
technology included.
2. Movement calibrated at more
points with tighter tolerances for
full range Class 1 (1% accuracy).
3. Polished solid brass case.
2-valve manifold – deluxe brass gauges
Refrigerants
Description
No hose
R-12, R-22, R-502
These manifolds have all the same
features as the regular “Series 41”
and an important upgrade – the
gauges. Manifolds are also available
with a variety of hoses.
LIQUID CHARGER
Liquid
charging is
recommended
when charging
blends into
refrigeration
and air
48
R-134a, R-404A, R-507
No hose
with 36" hose
with 60" hose
with no hose
with 36" hose
with 60" hose
41232
—
—
42332
—
—
1 Manifold with original HA hose
2 Manifold with PLUS II with standard fittings
conditioning systems. Since compressors cannot compress liquids, however,
you need a liquid charger adapter for
safe and fast liquid charging through
the low pressure side of a system. The
YELLOW JACKET adapter connects to the
cylinder valve or refrigerant can.
• To protect the compressor, adapter
1
2
3
—
—
—
—
41233
41235
—
43233
43235
—
—
44233
44235
—
—
—
42233
42235
—
—
42333
42335
42435
4
42436
3 Manifold with PLUS II with SealRight™ fittings
4 Manifold with PLUS II with compact valve
orifice reduces liquid flow to a level
below compressor capacity.
• Eliminates the time and work of
heating cylinders.
UPC #
Description
41123
1/4" liquid charging adapter
41124
5/16" liquid charging adapter
SERIES 41 MANIFOLD REPLACEMENT PARTS
40279: Heavy-duty swivel hook
REPLACEMENT GAUGES
Starting on page 60
41133: 1/4" Piston with "O" rings
and seal
49010: New crystal
41141: Handle and screw
41131: "O"-rings 10 pack
41142: Screws for valve handles (set of 2)
41134: Feed screw
41135: Retaining nut
On back side of some manifolds:
Old Bar
41143: Complete handle assembly – piston
with seal, "O"-rings, feed screw,
retaining nut and handle with screw
41150 3-plug hose anchor
40280 4-plug hose anchor
40281 4-plug hose anchor
with one 3/8" plug
working pressure for a 5 to 1 safety
factor.
MANIFOLD PARTS
KIT for Series 41,
TITAN, and
BRUTE II™
Manifolds
CHARGING
SYSTEMS
YELLOW JACKET PLUS II™ 1/4" CHARGING HOSES
with double barrier protection
Color-coded 3-Pak
Standard 1/4" fitting or 45° with
SealRight fitting at one end.
UPC#
• Operating temperature -20° to 180°F.
YELLOW JACKET PLUS II Hoses have
proven performance benefits of the
original line, plus double barrier
protection for CFC, HCFC and HFC
(R-134a, R-404A, R-407C, R-410A,
R-507, etc.).
• UL recognized assemblies
(File SA9737).
1. Nylon permeation barrier
meets UL requirements. 1/4"
PLUS II hose is UL 1963 recognized
component for R-12, R-134a, R-22,
R-500, and R-502 .
2. Moisture barrier provides improved
resistance to moisture migration
which contaminates expensive
refrigerant.
Other features include 4000 psi
minimum burst and 800 psi maximum
Description
Qty.
41099
41105
Complete Kit
Box only with label
1
1
41041
41042
Yellow Handle with Screw - TITAN
Blue Handle with Screw - TITAN
4
3
41044
41043
41048
Red Handle with Screw - TITAN
Piston - TITAN
Handle Screws (2) - TITAN
3
8
6
41049
41056
Valve Retaining Nut - TITAN
Feed Screw - TITAN
4
4
41061
Sight Glass (1), Retainer (1),
Gaskets (2) - BRUTE II/TITAN
4
41090
41091
Handle Screws (2) - BRUTE II
Yellow Handle with Screw - BRUTE II
6
4
41092
41094
41096
Blue Handle with Screw - BRUTE II
Red Handle with Screw - BRUTE II
Valve Retaining Nut - BRUTE II
3
3
4
41103
41106
41134
41135
41141
3/8" Piston - BRUTE II
Feed Screw - BRUTE II
Feed Screw - Series 41/TITAN
Valve Retaining Nut - Series 41/TITAN
Metal Handle with Screw - Series 41
8
4
6
6
4
41142
41133
Handle Screws (2) - Series 41/TITAN
1/4" Piston - Series 41 & TITAN
6
6
Kit contents
Plus II Hoses - standard 1/4" fittings
L.
Yellow
Blue
Red
3 - Pak
12"
24"
36"
48"
60"
21012
21024
21036
21048
21060
21212
21224
21236
21248
21260
21612
21624
21636
21648
21660
–
–
21983
21984
21985
72"
96"
10'
12'
25'
21072
21096
21110
21112
21125
21272
21296
21310
21312
21325
21672
21696
21710
21712
21725
21986
21988
–
–
–
50'
75'
100'
21150
21175
21200
21350
21375
21399
21750
21775
21799
–
–
–
Multi-length 3-Paks - 21982 two 36", one 60"
21981 two 36", one 72"
Hoses with 5/16" service end for R-410A
on page 27.
49
BRUTE™ MANIFOLD REPLACEMENT PARTS
40279:
Hanging hook
49091:
Red boot
49092:
Blue boot
REPLACEMENT
GAUGES –
Starting on
page 60
49090:
Set of 1 red,
1 blue boot
49000: Crystal
49010: crystal
41116: Brute overhaul kit
(4 pistons & 4 screens)
41103: 3/8" piston
41106: Feed screw
41108:
Sight glass
41102:
Blue handle
41107: Retaining nut
41109:
Sight glass
“O”-ring
41104:
Red handle
41117: particulate screens to go between
manifold body and half union (4 pack)
41142:
Handle screw
41101:
Yellow handle
BANTAM™ MANIFOLD REPLACEMENT PARTS
40279: Heavy-duty swivel hook
49100: Crystal for
3 1/8" gauge
41053: Piston/”O”-ring/seal
(Set of 2)
41051: Handle, yellow
41055: "O"-rings 10 pack
41052: Handle, blue
41056: Feed screw
41054: Handle, red
41057: Retaining nut
41058: Screws for handle (set 2 screws)
41061: Sight glass assembly
(glass, ring, seal)
41059: 1/4" anchor fittings
41060: 3/8" anchor fittings
50
41063: Particulate screens
(pack of 4)
AUTOMOTIVE R-134a MANIFOLD
MANIFOLD PARTICULATE FILTER
control valves.
The hoses meet
SAE J2196 and
are UL 1963
recognized.
Additional hose
construction
improvements increase working
pressure for increased safety. Hoses
available with Acme and 14 mm male
fittings. Available 5' or 10' hoses.
“Series 41” automotive manifold
comes complete with R-134a gauges,
environmental PLUS II hoses, and
special R-134a A/C couplers with
UPC #
Description
41343
Auto only R-134a manifold
60" hose with 1/2" Acme fittings
and 14 mm fittings, hose anchors
41345
41346
Above with R-134a couplers
Above with carrying case
41340
Auto only R-134a manifold
10' hoses with 1/2" Acme fittings,
14 mm fittings, hose anchors,
and R-134a couplers
SINGLE TEST
GAUGES
Single gauge
manifold. Check
pressure on low
side of system.
Nylon seals.
Double O-ring
pistons.
Quick pressure
checks – use low
or hi-side gauge
with quick coupler
to attach directly
to system or
tanks.
UPC# Description
40318
Low side manifold R-12, R-22, R-502
40319
Low side manif. R-404A, R-407C, R-134A
40320
Low side manifold R-410A
UPC #
Description
41119
41120
1/4" manifold particulate filter
3/8" manifold particulate filter
41121
41122
1/2" manifold particulate filter
Replacement filter screen (5 pk.)
YELLOW JACKET NH 3
AMMONIA MANIFOLD and Hose
CHARGING
SYSTEMS
SINGLE GAUGE
MANIFOLD
As
manifold usage
changes with more
recovery change outs, more
particulate matter is drawn through
manifolds. Trap the particles with these
fittings before they damage valve seats
or pass into your recovery equipment.
Replaceable, cleanable screens.
UPC #
Description
Gauge w/ QC & 12" hose - angle CPLG
40341
40342
14811
Red pressure °F
Blue compound °F
12" red hose 1/4" M. fl x 45° QC
Gauge with 19110 quick coupler
for recovery tank pressure checks
MANIFOLD CARRYING CASES
Blue heavy-duty blow molded case
to protect manifold and tools. Long
lasting hinge. Handle for easy carrying.
UPC #
Case description L x W x H
40261
40262
40263
41111
41112
Series 41 – 13-1/2" x 10" x 3-1/2"
Series 41 – 12-1/4" x 8" x 3-1/2"
Series 41 – 12-1/4" x 8" x 4-1/4"
Bantam™, BRUTE™ and TITAN™
BRUTE™, BRUTE II ™ and Digital Analyzer
40331
Red pressure °F
40332
19110
14821
Blue compound °F
Quick coupler only (see page 35)
12" blue hose 1/4" M. fl x 45° QC
“O”-RING
LUBRICANT
To lubricate “O”rings in manifolds
when pistons or “O”-rings are being
replaced. Use sparingly.
This heavy-duty manifold features cast
iron body and full size metal
handles. Other features:
• Finger-tight one-piece valve
stem for positive seal on nylon seat.
• Easy, accurate valve adjustment.
Dual temperature/pressure R717
gauge has bar with ˚C and psi with ˚F
ammonia scales.
UPC #
Description
40190
40192
Manifold body with valves
Manifold above and gauges
UPC #
Description
40193
Above with three NHA 48 hoses
41118
“O”-ring lubricant (.75 oz.)
40199
Replacement valve assembly
51
METRIC
Selection Guide for °C and °F/C (see page 41 for °F)
Range of performance for your business and budget
Choice of
copper or
forged
aluminum
alloy
Choice of
analog
or digital
gauges
A pattern
of ongoing
innovation
Reliability
and durability
across the line
Refrigerant
Series 41
UPC#
R-12, R-134a,
R-413A
41632
R-12, R-22,
R-502
41222
41223
41225
41282
R-22, R-134a,
R-404A
TITAN™ 2-valve
TITAN™ 4-valve
BRUTE II™ 4-valve
Page UPC#
Page UPC#
Page UPC#
Page
Digital Analyzer
Page
UPC#
57
41283
41285
41292
41293
41295 44225
43225 44285
43285 44295
43295
57
49806
49816
56
49906
49916
55
46120
46180
54
41622
57
49833
56
49933
55
46140
54
R-22, R-134a,
R-407C
41642
57
49803
56
49903
55
46150
54
R-134a, R-404A,
R-407C
41332
57
49836
49856
56
49936
49956
55
49130
46190
54
R-134a, R-404A,
R-507
41353 41365 43355 44355
41355 41382 43365
41363 41392 44365
57
R-410A
40944 41780
41652 41781
57
49869
49870
56
49969
49970
55
46160
46170
54
40802,
40805
53
For °F see page 41.
52
YELLOW JACKET DIGITAL REFRIGERATION SYSTEM ANALYZER
with system modulation bar graph for fast, accurate diagnostics
METRIC
• Rugged case construction with
rubber boot to tolerate impact and
resist typical oils, acids, and sunlight
• Digital readings show resolution of
1/4 psi on low side, 1 psi on high side
For time-saving diagnostics, the
easy-to-read pressure bar graphs of this
patented unit quickly tell you more than
you could ever see with the vibrating
needle of a typical pressure gauge. You
see pressure dynamics to readily know if
the system’s thermostatic expansion
valve is modulating properly, if liquid is
flooding back into the systems, and
more. Saturation, subcooling, and
superheat readings are automatic to
eliminate fishing in your wallet for
reference cards. This almost immediate
knowledge of system behavior and
faults can help save up to 10 minutes
and more on many jobs.
Rubber boot protects
instrument from minor
bumps and impacts.
Easy to Use:
• Bar graph segments shows changes
from digital reading (range of ±2
psi on low-side, ±8 psi on high-side)
Automatically
calibrates to
current
atmospheric
pressure
Changes
contrast
• Integrated temperature probe for
automatic superheat and subcooling
readings
• Max and min pressure monitoring
for control set-up
• Auto zero key to eliminate manual
recalibration
• Vacuum detection inHg
• Easy-to-read LCD screen with large
3/8" digits
Pressure accuracy:
0.5% F.S. ± 1 least significant
digit, calibration traceable to NIST
Pressure ports:
Two 1/8" acting as low and
high side gauges
Working pressure:
Low side: 0-200 psi (1350 kPa,
13.5 bar)
High side: 0-550 psi (3790 kPa,
37.9 bar)
Proof pressure:
Low side: 600 psi (4100 kPa,
41 bar)
High side: 1500 psi (10300 kPa,
103 bar)
Burst pressure:
Low side: 2000 psi (13500 kPa,
135 bar)
High side: 5000 psi (34500 kPa,
345 bar)
Temperature sensor range:
-40° to 125°C (-40° to 250°F)
Resets
peak pressure
memory
Selects temperature,
superheat, subcooling,
max/min pressure
CHARGING
SYSTEMS
Changes
the digits
update rate
Specifications:
• Profiles 22 common refrigerants:
R-12
R-404A
R-416A
R-22
R-406A
R-417A
R-134a
R-407C
R-420A
R-290
R-408A
R-502
R-401A
R-409A
R-507
R-401B
R-410A
R-508B
R-402A
R-414B
R-600A
R-402B
(Upgradeable for new refrigerants)
• Temperature, superheat or
subcooling shown on lower right
(eg. 10°F superheat).
Selects
active
refrigerant
Changes
between
traditional (psi,
"Hg,°F) and
international
system of units
(kPa, bar, °C)
Features:
• Temperature in middle is
corresponding bubble and dew
points for current pressures
Temperature accuracy:
±0.5°C (±0.9°F) between
0° to 70°C (32° to 158°F)
Usage environment:
Indoor/Outdoor dew, splash and
rain resistant; do not immerse
in water
Storage and operational temperature:
-20° to 50°C (-4° to 122°F)
Power supply:
4 AA Batteries (approx. 6 months
under normal use)
Weight:
.725 kg (1.6 lb.)
Dimensions:
17 x 12.2 x 6.4 cm (6.7 x 4.8 x 2.5" )
UPC # Description
40801
40802
40805
R-410A adapter kit – 1/4" to 5/16" service fitting
Digital analyzer on TITAN™ 4-valve manifold
40802 with 1/4" x 60" RYB and
3/8" x 60" yellow PLUS II™ hoses
41067
41068
41069
Temperature Probe
Extended Manifold Hook
Rubber Boot
53
YELLOW JACKET BRUTE II ™ 4-valve Test & Charging Manifold - °C
Forged aluminum alloy body with
full 3/8" bore for faster vacuum
and charging
METRIC
Large, easy-to-read
3-1/8" (80 mm)
red and blue steel case
1% accuracy
(Class 1) gauges
with protective boots;
The new BRUTE II™ 4-Valve Test and
Charging Manifold has been trimmed
down for lighter weight but with the
same powerful performance of the original model. This streamlined unit continues to provide the flow that's proven
faster than any conventional manifold.
And even though sleeker and more
compact, the aluminum alloy is forged
for strength and reliability with 3/8"
bores through the body to speed the
job.
Other Features and Benefits:
• Fourth hose enables connection to
hi/lo sides, refrigerant tank, and
recovery unit or vacuum pump for
diagnostics, evacuation and charging
without switching hoses.
– 1/4" hi/lo sides with 3/8" vacuum
port for regular jobs, or;
– 3/8" hi/lo sides with 1/2" vacuum
port for larger systems.
• Front access for easy field
recalibration.
• Proven, double “O”-ring piston for
reliability and long service life.
• Exclusive 100-mesh filter in-line
on all flare fittings helps keep out
particulate material and extend the
life of the seat.
• Sight glass to easily view
refrigerant movement and condition
during charging and recovery.
• Heavy-duty hook won’t pull out.
• Contoured easy-grip handles for
positive control; color coded for
ready identification.
Refrigerants
UPC #
Scale
Manifold Fittings
Hose Holder Fittings
R-22/134a/407C
R-12/22/502
46150
46120
bar/psi
bar/MPa
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
R-22/134a/404A
46180
46140
bar/psi
bar/psi
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
46130
46190
46160
bar/MPa
bar/psi
bar/psi
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
5/16 - 3/8 - 1/4 - 5/16"
46170
bar/psi
5/16 - 3/8 - 5/16 - 5/16"
5/16 - 3/8 - 5/16 - 5/16"
R-134a/404A/407C
For °F see page 43.
For replacement parts see page 46.
• Also available with YELLOW JACKET®
80 mm (3-1/8") red and blue liquidfilled gauges.
R-410A
For information on the certification of 3-1/8" gauges, see page 40.
PROTECTIVE GAUGE BOOTS for 63.5 mm (2-1/2") and 80 mm (3-1/8") gauges
Rubber boots slip easily around gauges to
cushion and protect them from impact.
• Fit 2-1/2" and 3-1/8" gauges
without covering easy access
recalibration screw
• Color-coded red or blue to match gauge
54
UPC #
Size
Description
49090
49091
49092
49190
49191
49192
63.5 mm (2-1/2")
63.5 mm (2-1/2")
63.5 mm (2-1/2")
80 mm (3-1/8")
80 mm (3-1/8")
80 mm (3-1/8")
Set of gauge boots
Red protective gauge boot
Blue protective gauge boot
Set of gauge boots
Red protective gauge boot
Blue protective gauge boot
YELLOW JACKET TITAN™ 4-Valve Test & Charging Manifold - °C
METRIC
Forged aluminum alloy body
for increased strength and reliability
The new TITAN ™ Test and Charging
Manifold is the first forged aluminum
manifold in the industry. Special
aluminum alloy body makes this unit
lightweight for handling ease with the
durability and reliability required for
repeated, rugged use.
Features/Benefits
• Large, easy-to-read 80 mm (3-1/8")
steel case red and blue, Class 1
(1% accuracy) gauges; front access
for easy field recalibration; optional
protective gauge boots available.
• Proven, double “O”-ring piston for
reliability and long service life.
CHARGING
SYSTEMS
• Exclusive 100 mesh filter in-line on
all flare fittings helps keep out
particulate material and extend the
life of the seats.
• Contoured easy-grip handles for
positive control; color coded for
ready identification.
• Sight glass to easily view
refrigerant movement and condition
during charging and recovery.
• 3/8" vacuum port for use with
larger hose to cut evacuation time
by up to 33% (all other fittings on
unit are 1/4").
• Also available with YELLOW JACKET®
80 mm (3-1/8") red and blue
liquid-filled gauges.
• Heavy duty hook won’t pull out.
Refrigerants
UPC #
Scale
Manifold Fittings
Hose Holder Fittings
4-Valve Features/Benefits
R-22/134a/407C
R-12/22/502
49903
49906
49916
49933
bar/psi
bar/MPa
bar/psi
bar/psi
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
R-134a/404A/407C 49936
49956
R-410A
49969
49970
bar/MPa
bar/psi
bar/psi
bar/psi
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
5/16 - 3/8 - 5/16 - 5/16"
1/4 - 3/8 - 1/4 - 1/4"
1/4 - 3/8 - 1/4 - 1/4"
5/16 - 3/8 - 1/4 - 5/16"
5/16 - 3/8 - 5/16 - 5/16"
• Fourth hose to enable connection
to hi/lo sides, refrigerant tank, and
recovery unit or vacuum pump for
diagnostics, evacuation and charging
without switching hoses.
For °F see page 44.
For replacement parts see page 46.
R-22/134a/404A
For information on the certification of 3-1/8" gauges, see page 40.
55
YELLOW JACKET TITAN™ 2-Valve Test & Charging Manifold - °C
METRIC
Forged aluminum alloy body
and large easy-to-read gauges
The new TITAN™ Test and Charging
Manifold is the first forged aluminum
manifold in the industry. The special
aluminum alloy construction of the
manifold body makes this unit
lightweight for handling ease with the
durability and reliability required for
repeated, rugged use.
Features/Benefits
• Large, easy-to-read 80 mm (3-1/8")
steel case red and blue, Class 1
(1% accuracy) gauges; front access
for easy field recalibration; optional
protective gauge boots available.
• Proven, double “O”-ring piston for
reliability and long service life.
• Exclusive 100 mesh filter in-line on
all flare fittings helps keep out
particulate material and extend the
life of the seats.
• Contoured easy-grip handles for
positive control; color coded for
ready identification.
• Sight glass to easily view
refrigerant movement and condition
during charging and recovery.
• Heavy duty hook won’t pull out.
For °F see page 45.
For replacement parts see page 46.
Refrigerants
UPC #
Scale
Manifold Fittings
Hose Holder Fittings
R-22/134a/407C
R-12/22/502
49803
49806
bar/psi
bar/MPa
All fittings 1/4"
All fittings 1/4"
All fittings 1/4"
All fittings 1/4"
49816
R-22/134a/404A
49833
R-134a/404A/407C 49836
bar/psi
bar/psi
bar/MPa
All fittings 1/4"
All fittings 1/4"
All fittings 1/4"
All fittings 1/4"
All fittings 1/4"
All fittings 1/4"
49856
49869
bar/psi
bar/psi
All fittings 1/4"
All fittings 1/4"
All fittings 1/4"
5/16 - 1/4 - 5/16"
49870
bar/psi
All fittings 5/16"
All fittings 5/16"
R-410A
For information on the certification of 3-1/8" gauges, see page 40.
56
YELLOW JACKET SERIES 41 MANIFOLDS with 63.5 mm (2-1/2") gauges
Only 1-1/2 turns give you full flow.
Long-life nylon seat is also for vacuum
and R-134a, R-404A, R-507, R-407C,
R-410A, etc.
pulsation
for easier,
more
accurate
readings.
Heavy-duty
swivel hook.
Flutterless
Standard
Limited Lifetime Warranty on manifold bar and valves – not gauges. See
manifold instructions for details.
Pretested. Every manifold is
individually tested for reliability
before shipping.
41282
41283
41285
43285
44285
41382
41353
41355
43355
44355
R-134a, 41332
R-404A,
R-407C
R-134a,
R-404A, R-507
Forged brass body with metal valve
handles. Forged body is solid brass
for durability. Full porting maximizes
capacity. Metal valve handles are full
size for easy operation. Hose anchors
are forged into back of body at 45°.
R-12, R-22, R-502
Sliding double "O"-ring pistons.
Non-rotating design reduces wear.
UPC#
bar/psi
METRIC
YELLOW JACKET Hoses. Most
manifolds include color-coded YELLOW
JACKET charging hoses.
Easy-to-read 63.5 mm (2-1/2") steel
case gauges (°C) with 3-2-3% accuracy.
For °F see page 47.
For replacement parts see page 49.
UPC#
kPa/psi
UPC#
kg/cm2/psi
Hoses/hose holder fittings
41222
41223
41225
43225
44225
–
–
–
–
–
–
41292
41293
41295
43295
44295
41392
41363
41365
43365
44365
–
None – 1/4" – 1/4" – 1/4"
HA36 RYB – 1/4" – 1/4" – 1/4"
HA60 RYB – 1/4" – 1/4" – 1/4"
PLUS II 60" RYB – 1/4" – 1/4" – 1/4"
PLUS II SealRIght 60" – 1/4" – 1/4" – 1/4"
None – 1/4" – 1/4" – 1/4"
HA36 RYB – 1/4" – 1/4" – 1/4"
HA60 RYB – 1/4" – 1/4" – 1/4"
PLUS II 60" RYB – 1/4" – 1/4" – 1/4"
PLUS II SealRIght 60" – 1/4" – 1/4" – 1/4"
None – 1/4" – 1/4" – 1/4"
R-410A
bar/MPa
Flutterless ™ Technology. Surge
protector and silicone dampened
movement helps minimize needle
40944
41781
41780
Hi /Lo ports
Center port
1/4"
5/16"
1/4"
1/4" T-fitting
5/16"
1/4"
CHARGING
SYSTEMS
R-410A manifolds can have a variety of fitting and hose holders on them
Hoses/hose holder fittings
All 5/16"
None – 5/16" – 5/16" – 5/16"
None – 1/4" – 1/4" – 1/4"
For information on the certification of 3-1/8" gauges, see page 40.
YELLOW JACKET SERIES 41 MANIFOLDS with 80 mm (3-1/8") gauges
This field-proven manifold line has now
been expanded to include larger, easier
to read 80 mm (3-1/8") color-coded
gauges in rugged steel cases with
polycarbonate crystals.
Most importantly, these gauges feature
1% accuracy for an exact reading in
critical charge systems.
Features
• Wide choice of refrigerant
combinations including:
• R-22, R-134a, R-404A
• R-12, R-22, R-134a
• R-22, R-404A, R-410A
METRIC
• Color-coded scales with bold, easy
to read dials.
• Dials with Class 1 (1% accuracy )
for critical charge systems.
• Proven sliding double “O”-ring
pistons reduce wear.
• Long life nylon seats.
• Forged brass body for durability.
• Full porting maximizes capacity
and flow.
• Some models include color-coded,
60" PLUS II™ hoses with standard
1/4" flare fittings.
Refrigerants
UPC#
Gauge
R-410A
41652
80 mm (3-1/8") Red/Blue
bar/psi
1/4-1/4 T-fitting -1/4"
All 5/16"
R-22/134a/407C
41642
80 mm (3-1/8") Red/Blue
bar/psi
All 1/4"
All 1/4"
R-22/134a/404A
41622
80 mm (3-1/8") Red/Blue
bar/psi
All 1/4"
All 1/4"
R-12/134a/413A
41632
80 mm (3-1/8") Red/Blue
bar/psi
All 1/4"
All 1/4"
For information on the certification of 3-1/8" gauges, see page 40.
Scale
• Hose assemblies UL recognized for
275 bar (4000 psi) burst and 55 bar
(800 psi) working pressure.
File# SA9737.
Manifold Fittings
Hose Holder Fittings
For °F see page 48. For replacement parts see page 49.
57
AUTOMOTIVE R-134a MANIFOLD
YELLOW JACKET NH 3
AMMONIA MANIFOLD and Hose
“Series 41”
automotive
manifold
comes
complete
with R-134a
gauges,
environmental PLUS II hoses, and
special R-134a A/C couplers with
control valves. The hoses meet SAE
J2196 and are UL 1963 recognized.
Additional hose construction
improvements increase working
pressure for increased safety. Hoses
available with Acme and 14 mm male
fittings. Available 5' or 10' hoses.
LIQUID CHARGER
MANIFOLD CARRYING CASES
UPC #
Description
41343
Auto only R-134a manifold
60" hose with 1/2" Acme fittings
and 14 mm fittings, hose anchors
41345
41346
Above with R-134a couplers
Above with carrying case
41340
Auto only R-134a manifold
10' hoses with 1/2" Acme fittings,
14 mm fittings, hose anchors,
and R-134a couplers
Blue heavy-duty blow molded cases are
available in four different sizes for all the
different manifold/hose configurations.
Includes handle and a long life top hinge.
This heavy-duty manifold features cast
iron body and full size metal
handles. Other features:
• Finger-tight one-piece valve
stem for positive seal on nylon seat.
• Easy, accurate valve adjustment.
Dual temperature/pressure R717
gauge has bar with °C and psi with °F
ammonia scales.
Liquid charging is recommended
when charging blends into refrigeration
and air conditioning systems. Since
compressors cannot compress liquids,
however, you need a liquid charger
adapter for safe and fast liquid
charging through the low pressure
side of a system. The YELLOW JACKET
adapter connects to the cylinder valve
or refrigerant can.
• To protect the compressor, adapter
orifice reduces liquid flow to a level
below compressor capacity.
• Eliminates the time and work of
heating cylinders.
UPC #
Description
41123
1/4" liquid charging adapter
41124
5/16" liquid charging adapter
UPC # Case description L x W x H
40261
40262
Series 41 – 13-1/2" x 10" x 3-1/2"
Series 41 – 12-1/4" x 8" x 3-1/2"
40263
41111
41112
Series 41 – 12-1/4" x 8" x 4-1/4"
Bantam™, BRUTE™ and TITAN™
BRUTE™, BRUTE II ™ and Digital Analyzer
MANIFOLD PARTICULATE FILTER
As manifold
usage changes with
more recovery change
outs, more particulate matter is
drawn through manifolds. Trap the
particles with these fittings before they
damage valve seats or pass into your
recovery equipment. Replaceable,
cleanable screens.
UPC #
Description
40190
Manifold body with valves
40192
Manifold above and gauges
UPC #
Description
40193
Above with three NHA 48" hoses
40199
Replacement valve assembly
41119
41120
1/4" manifold particulate filter
3/8" manifold particulate filter
41121
41122
1/2" manifold particulate filter
Replacement filter screen (5 pk.)
58
YELLOW JACKET Specialized and General
Use Gauges – reliable
monitoring of vacuum
and pressure
Selected gauges
now certified for your
confidence and
convenience
59
YELLOW JACKET Certified Gauges – 10-point measurement
and documentation for your confidence and convenience
You make decisions
based on what your
gauge is telling you.
Now you
can have greater
confidence in your
measurements and
decisions with a line of certified
YELLOW JACKET Class I Replacement
Manifold Gauges and Manifolds with
Class I gauges.
YELLOW JACKET gauges have always
been manufactured and calibrated to
NIST standards (National Institute of
Standards and Technology). The
standard Ritchie procedure has been to
measure for accuracy at five points:
two times – up the scale and then back
down. Many manufacturers measure at
only three points (A, B, C).
calibration plus compliance to ANSI
Z540.1 and ISO 10012 standards.
The certification is good for one
year and then recalibration is
recommended. Serialized, dated
certificates are packed with each
certified unit.
Certification benefits:
• Convenience and time savings
2-1/2” Brass Manifold Gauge
with Class 1 Accuracy
Feel confident even if you are
servicing critical applications such as
ice machines or other equipment with
precise charging requirements.
• Convenient documentation to help
meet ISO requirements
A calibration certificate accompanies each
Calibrated Gauge and the back of each
Certified Gauge is clearly identified with a label
applied by the certifying Ritchie technician.
Calibration Certificate Information
The certificate packed with each
certified gauge provides evidence of
calibration standards traceable to
NIST and includes a serial number that
matches the serial number on the
gauge. Ritchie Engineering maintains
records of each sale as a back up to
your records.
4” Manifold
Gauge with Class 1
Accuracy
3-1/8” Manifold Gauge
with Class 1 Accuracy
In the past when you wanted
certification, you had to purchase the
gauge at one location and then take it
to a calibration house. Now you save
the time of the second step.
• Easy compliance with a quality
policy
Now, the Ritchie certification
process documents the NIST
• Accuracy assurance
Certified gauges help achieve and
prove the level of quality that your
employer or customer expects.
A calibration certificate contains
information for necessary traceability:
• Establish the identity and credibility
of the calibrating laboratory
• Uniquely identify the instrument
and its owner
• Identify the measurements made
• Provide a definite statement of the
results, including an uncertainty
statement
LARGE 4'' MANIFOLD GAUGES (°F) RED AND BLUE
with 1% accuracy (Class 1) calibration
Color-coded blue
for compound and
red for pressure
(not shown here)
Color-coded four
refrigerant types:
R-22, R-134a,
R-404A, R-410A
For reliable performance and durability, these 4" gauges are
housed in a red or blue steel case with front recalibrator screw.
High visibility colored temperature scales are easy
to read through the full view polycarbonate crystal.
Several features combine for improved accuracy: Flutterless™
technology with brass surge protector to minimize needle
pulsation; brass gauge movement, and copper alloy bourdon tube.
• 1/8" NPT Male connection.
• Calibrated to 1% accuracy at the plant.
UPC# Size
Description
Press. Scale
Refrigerants
49185
4"
Red pressure
0 - 500 psi
R-22, 134a, 404A, 410A
°C gauges on page 65.
49186
4"
Blue compound
30"-0-120* psi
R-22, 134a, 404A, 410A
60
*Features retard protection to 500 psi
LARGE 3-1/8" DRY MANIFOLD GAUGES (°F)
RED AND BLUE with 1% accuracy
(Class 1) calibration
HEAVY DUTY 2-1/2" BRASS MANIFOLD GAUGES
(˚F) with 1% accuracy (Class 1) calibration
Color-coded red for pressure and
blue for compound
Bold numbers for
easy reading
Glass
crystals
Color-colored for
refrigerant type
Steel case
for durability
Easy access
recalibration screw
(not covered by
boot)
For reliable performance and durability, these 3-1/8" gauges
are housed in a red or blue steel case with front recalibrator
screw. High visibility colored temperature scales are easy
to read through the full view polycarbonate crystal.
Solid brass case and premium movements. Heavy duty
phosphor bronze and stainless steel internal components
for longer service life under severe use. 1% accuracy
(Class 1) calibration. Flutterless™ technology with brass
surge protector to minimize needle pulsation.
Several features combine for improved accuracy:
Flutterless™ technology with brass surge protector to
minimize needle pulsation; brass gauge movement, and
copper alloy bourdon tube.
• 1/8" NPT Male connection.
• Calibrated to 1% accuracy at the plant.
Refrigerants
• 1/8" NPT Male connection.
2-1/2" Brass pressure
2-1/2" Brass compound
0 - 500 psi
30"-0-120* psi
• Calibrated to 1% accuracy at the plant.
49067 2-1/2" Brass pressure
49068 2-1/2" Brass compound
49049 Set of 49047, 49048
49069 Set of 49067, 49068
Certified Gauges
49197 2-1/2" Brass pressure
49198 2-1/2" Brass compound
0 - 500 psi
30"-0-120* psi
R-12, 22, 502
R-12, 22, 502
R- 22, 134a, 404A
R- 22, 134a, 404A
0 - 500 psi
30"-0-120* psi
49199
2-1/2" Brass pressure
0 - 500 psi
49200
49010
2-1/2" Brass compound
30"-0-120* psi
R- 22, 134a, 404A
Replacement crystal (polycarbonate) for old 49011, 49012
49039
49040
Glass crystal for brass gauge
Brass gauge ring
Description
Press. Scale
Refrigerants
49101
49102
49103
49104
3-1/8"
3-1/8"
3-1/8"
3-1/8"
Red pressure
Blue compound
Red pressure
Blue compound
49105
49106
49135*
49136*
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
Red pressure
Blue compound
Red pressure
Blue compound
Red pressure
Blue compound
0 - 500 psi
30"-0-120** psi
0 - 500 psi
30"-0-120** psi
0 - 500 psi
30"-0-120** psi
0 - 800 bar/psi
30"-0-300*** bar/psi
0 - 500 psi
30"-0-120** psi
0 - 500 psi
30"-0-120** psi
R-12, 22, 502
R-12, 22, 502
R-12, 22, 134a
R-12, 22, 134a
R-22, 134a, 404A
R-22, 134a, 404A
R-410A
R-410A
R-22, 404A, 410A
R-22, 404A, 410A
R-134a, 404A, 407C
R-134a, 404A, 407C
49137
49138
49151 3-1/8" Red pressure
49152 3-1/8" Blue compound
Certified Gauges
49201 3-1/8" Red pressure
0 - 500 psi
49202 3-1/8" Blue compound 30"-0-120** psi
R-12, 22, 502
R-12, 22, 502
49203 3-1/8" Red pressure
0 - 500 psi
R-12, 22, 134a
49204 3-1/8" Blue compound 30"-0-120** psi
R-12, 22, 134a
49205 3-1/8" Red pressure
0 - 500 psi
R-22, 134a, 404A
49206 3-1/8" Blue compound 30"-0-120** psi
R-22, 134a, 404A
49235* 3-1/8" Red pressure
0 - 800 bar/psi
R-410A
49236* 3-1/8" Blue compound 30"-0-300*** bar/psi R-410A
49237
49238
3-1/8" Red pressure
0 - 500 psi
3-1/8" Blue compound 30"-0-120** psi
49251
49252
49100
3-1/8" Red pressure
0 - 500 psi
3-1/8" Blue compound 30"-0-120** psi
Replacement crystal
* These gauges have °C and °F on dial
** Features retard protection to 350 psi
*** Features retard protection to 500 psi
R-22, 404A, 410A
R-22, 404A, 410A
R-134a, 404A, 407C
R-134a, 404A, 407C
Description
R-12, 22, 502
R-12, 22, 502
R- 22, 134a, 404A
*Features retard protection to 350 psi
Calibration traceable to NIST standards
Note: Gauges on this page are not
meant to be used with nitrogen.
Why should I zero out a manifold gauge? As a general
rule, a gauge can get off “0” due to a change in altitude
or barometric pressure. It’s important that you check to
see that it’s set back to “0” before you start charging. To
reset a gauge, look for the reset screw that will be located
on the front or back of the gauge. Then use a small blade
screw driver to set the dial back to “0”.
61
GAUGES
Press. Scale
49047
49048
UPC# Size
UPC# Size
YELLOW JACKET 2-1/2" MANIFOLD GAUGES (˚F)
RED AND BLUE
(Class B)
L
STESEES
CA
LIQUID-FILLED 3-1/8" MANIFOLD GAUGES
(˚F) RED AND BLUE (Class B)
All YELLOW JACKET gauges
feature bold high-visibility
dials with colored temperature
scales for easy reading.
• Flutterless™ technology
surge protector
minimizes the needle
pulsation for improved
accuracy
Glycerine filled gauges
are larger 3-1/8" diameter
for easy reading with
refrigerants color coded
on dials. Liquid filled gauges
dampen pulsation. Gauges calibrated to
3-2-3 (Class B) accuracy. Back recalibrator screw.
1/8" NPT Male connection.
• 1/8" NPT Male
connection
• 3-2-3% accuracy
• Calibration traceable
to NIST standards
UPC# Size
Description
Press. Scale
Refrigerants
0 - 500 psi
30"-0-120** psi
R-12, 22, 502
R-12, 22, 502
R-12, 22, 502
R-12, 22, 134a
R-12, 22, 134a
R-22, 134a, 404A
R-22, 134a, 404A
49001
49002
49008
49013
49014
2-1/2" Red pressure
2-1/2" Blue compound
Set red and blue gauges
2-1/2" Red pressure
2-1/2" Blue compound
49015
49016
2-1/2" Red pressure
0 - 500 psi
2-1/2" Blue compound 30"-0-120** psi
0 - 500 psi
30"-0-120** psi
49035* 2-1/2" Red pressure
49036* 2-1/2" Blue compound
49051 2-1/2" Red pressure
49052 2-1/2" Blue compound
49000
0 - 800 kg/cm2 /psi
R-410A
30"-0-300*** kg/cm2/psi R-410A
0 - 500 psi
R-134a, 404A, 507
30"-0-120** psi
R-134a, 404A, 507
Replacement crystal for gauges from 1984 and earlier
49010
Replacement crystal
* These gauges have C and F on dial
** Features retard protection to 350 psi
*** Features retard protection to 500 psi
Note: Small screw in back is 6/32" x 5/32" Phillips pan head screw.
Note: Gauges not meant to be used with nitrogen.
The growing preference for 3-1/8" gauges
3-1/8" gauges are fast
becoming the market preference.
Why? Larger dials with
1% accuracy (Class 1) full scale
movements give a more accurate
reading of the pressure in the
system (the most common gauges
are 2-1/2" with 3-2-3 accuracy).
And the color-coded temperature
dials are easier to read.
62
UPC# Size
Description
Press. Scale
Refrigerants
49071
49072
3-1/8"
3-1/8"
Red pressure
Blue compound
0 - 500 psi
30"-0-120** psi
R-134a, 404A, 407C
R-134a, 404A, 407C
49079
49080
49081
49082
3-1/8"
3-1/8"
3-1/8"
3-1/8"
Red pressure
Blue compound
Red pressure
Blue compound
0 - 500 psi
30"-0-120** psi
0 - 500 psi
30"-0-120** psi
R-22, 134a, 404A
R-22, 134a, 404A
R-12, 22, 502
R-12, 22, 502
49083
49084
49177*
49178*
3-1/8"
3-1/8"
3-1/8"
3-1/8"
Red pressure
Blue compound
Red pressure
Blue pressure
49179
49180
3-1/8"
3-1/8"
Red pressure
Blue compound
0 - 500 psi
30"-0-120** psi
0 - 800 bar/psi
30"-0-350*** bar/psi
0 - 500 psi
30"-0-120** psi
R-12, 22, 134a
R-12, 22, 134a
R-410A
R-410A
R-22, 404A, 410A
R-22, 404A, 410A
49095
49096
Replacement glycerine 6 oz. – will fill one gauge
Filler caps for liquid gauges
* These gauges have °C and °F on dial
** Features retard protection to 240 psi
*** Features retard protection to 500 psi
PROTECTIVE GAUGE BOOTS
for 2-1/2" and 3-1/8" gauges
Rubber boots slip easily
around gauges to cushion and
protect them from impact.
• Fit 2-1/2" and 3-1/8" gauges
without covering easy access
recalibration screw
• Color-coded red or blue
to match gauge
UPC #
Size
Description
49090
49091
49092
49190
49191
49192
2-1/2"
2-1/2"
2-1/2"
3-1/8"
3-1/8"
3-1/8"
Set of gauge boots
Red protective gauge boot
Blue protective gauge boot
Set of gauge boots
Red protective gauge boot
Blue protective gauge boot
STAINLESS 4-1/2"
CONTRACTOR GAUGE
YELLOW JACKET 1-1/2" to 3-1/2" GAUGES
2" dial 1/8" NPT Male lower connection
UPC #
Range psi – bar
Large 4-1/2" dial for easy reading.
Stainless steel case. Brass movement
and 1/4" NPT Male socket bottom
mount. Gauge has recalibrator screw. A
surge protector to help dampen needle
pulsation. 1% accuracy (Class 1)
calibration full scale.
General use gauges for multiple
application where pressure or vacuum
gauges are required. Brass internals
are suitable for air, gas, water and oil
plus many more industry applications.
• No restrictor
• Recalibration feature is standard on
2-1/2" and 3-1/2" gauges
49340
49341
49342
0-15 psi
0-30 psi
0-60 psi
(0-1 bar)
(0-2 bar)
(0-4 bar)
49344
49345
49346
49347
49353
49355
0-100 psi
0-160 psi
0-200 psi
0-300 psi
0-30 inHg VAC
30"-0-30 psi
(0-7 bar)
(0-11 bar)
(0-14 bar)
(0-20 bar)
(0 to -1 bar)
(-1-0-2 bar)
49357
30"-0-100 psi
(-1-0-7 bar)
2-1/2" dial 1/4" NPT Male lower connection
UPC #
Range psi – bar
49380
49381
49382
0-15 psi
0-30 psi
0-60 psi
(0-1 bar)
(0-2 bar)
(0-4 bar)
49384
0-100 psi
(0-7 bar)
49385
49386
49387
0-160 psi
0-200 psi
0-300 psi
(0-11 bar)
(0-14 bar)
(0-20 bar)
49388
49393
0-400 psi
0-30 inHg VAC
(0-28 bar)
(0 to -1 bar)
49395
49396
49397
49398
30"-0-30 psi
30"-0-60 psi
30"-0-100 psi
30"-0-150 psi
(-1-0-2 bar)
(-1-0-4 bar)
(-1-0-7 bar)
(-1-0-10 bar)
4-1/2" dial 1/4" NPT Male lower connection
UPC #
Range psi – bar
• Steel cases painted black with glass
crystal and metal ring
49440
0-15 psi
(0-1 bar)
• Gauge accuracy is 3-2-3%
49441
49442
49444
0-30 psi
0-60 psi
0-100 psi
(0-2 bar)
(0-4 bar)
(0-7 bar)
Contact the factory for special
applications.
49445
49446
0-160 psi
0-200 psi
(0-11 bar)
(0-14 bar)
1-1/2" dial 1/8" NPT Male lower connection
UPC #
Range psi – bar
49447
49453
49455
0-300 psi
0-30 inHg VAC
30"-0-30 psi
(0-20 bar)
(0 to -1 bar)
(-1-0-2 bar)
49301
49302
0-30 psi
0-60 psi
(0-2 bar)
(0-4 bar)
49456
49457
30"-0-60 psi
30"-0-100 psi
(-1-0-4 bar)
(-1-0-7 bar)
49304
49305
0-100 psi
0-160 psi
(0-7 bar)
(0-11 bar)
49420
49421
0-15 psi
0-30 psi
(0-1 bar)
(0-2 bar)
49306
0-200 psi
(0-14 bar)
49458
30"-0-150 psi
(-1-0-10 bar)
49422
49424
0-60 psi
0-100 psi
(0-4 bar)
(0-7 bar)
49425
49426
49427
0-160 psi
0-200 psi
0-300 psi
(0-11 bar)
(0-14 bar)
(0-20 bar)
49428
49433
0-400 psi
0-30 inHg VAC
(0-28 bar)
(0 to -1 bar)
49435
49436
49437
49438
30"-0-30 psi
30"-0-60 psi
30"-0-100 psi
30"-0-150 psi
(-1-0-2 bar)
(-1-0-4 bar)
(-1-0-7 bar)
(-1-0-10 bar)
DIAPHRAGM 2-1/2" GAUGES –
LOW PRESSURE
1-1/2" dial 1/8" NPT Male lower connection
UPC #
Range psi –
bar
49321
49322
49324
0-30 psi
0-60 psi
0-100 psi
(0-2 bar)
(0-4 bar)
(0-7 bar)
49325
49326
0-160 psi
0-200 psi
(0-11 bar)
(0-14 bar)
2" dial 1/4" NPT Male lower connection
UPC #
Range psi – bar
The bronze diaphragm is designed
for better protection on incidental
overpressure. Intended for low pressure
applications only. Black steel case.
UPC# Size
Range
Connection
78056
78061
78057
78066
0-10” W.C.
0-35” W.C.
0-10” W.C.
0-35” W.C.
barb type
barb type
1/4" NPT Male
1/4" NPT Male
2-1/2"
2-1/2"
2-1/2"
2-1/2"
49360
0-15 psi
(0-1 bar)
49361
49362
0-30 psi
0-60 psi
(0-2 bar)
(0-4 bar)
49364
49365
49366
49367
0-100 psi
0-160 psi
0-200 psi
0-300 psi
(0-7 bar)
(0-11 bar)
(0-14 bar)
(0-20 bar)
49373
49375
49377
0-30 inHg VAC
30"-0-30 psi
30"-0-100 psi
(0 to -1 bar)
(-1-0-4 bar)
(-1-0-10 bar)
GAUGES
Note: Can be used for oil pressure.
3-1/2" dial 1/4" NPT Male lower connection
UPC #
Range psi – bar
Note: Warranty on gauges does
not cover damage due to excessive
pressure.
Note: Cannot be recalibrated.
63
MECHANICAL VACUUM GAUGES –
1-1/2" and 3-1/8"
Full range mechanical bourdon tube gauges for determining
system vacuum. Much more accurate than a compound
gauge. All gauges are 1/8" NPT Male bottom connection.
3-1/8" gauges are larger to show vacuum more accurately
in inches of mercury and Torr (or millibar).
1-1/2" gauges are used on YELLOW JACKET vacuum pumps.
CAUTION: Vacuum gauges must be handled carefully.
Dropping, pressurizing and rough handling reduce their life.
UPC# Size
Scale
93011 1-1/2"
69044 3-1/8"
69045 3-1/8"
Red/green arc
1/8" NPT Male back
0-30" Hg & 760-0 Torr
1/8" NPT Male lower
1000-0 millibar & 30-0" (Euro.) 1/8" NPT Male lower
Connection
Case
Black/steel
Green/steel
Green/steel
AMMONIA GAUGES 2-1/2" and 3-1/2" with dual scale
Ammonia gauges are designed for use
on manifolds and as permanent gauges
on any system or equipment charged
with ammonia. The bourdon tube is
made of 316 stainless. The sockets are
steel. The dials show dual temperature
and pressure scales. All gauges are
equipped with restrictors to protect
the gauges against pulsating pressure.
Steel gauge cases are painted black.
Gauges calibrated to 3-2-3% accuracy.
1/4" NPT Male connection.
UPC#
Size
Description
Range
40201
40202
40206
2-1/2"
2-1/2"
3-1/2"
Gauge with twist on polycarbonate crystal
Gauge with twist on polycarbonate crystal
Gauge with metal ring and lens
40205
49010
49495
3-1/2"
2-1/2"
3-1/2"
Gauge with metal ring and lens
Replacement crystal
Replacement lens
30" - 0 - 400 psi °F and 76-0-28 kg/cm2 °C
30" - 0 - 150 psi °F and 76-0-10 kg/cm2 °C
30" - 0 - 300 psi °F and 76-0-22 kg/cm2 °C
30" - 0 - 150 psi °F and 76-0-10 kg/cm2 °C
Recalibrate for atmospheric
pressure variations?
Atmospheric pressure variations are
of little importance with gauging
pressures typically encountered in
refrigeration and A/C service work.
With a change of 2 inHg, the gauge
changes by only 1 psi. It is unlikely
that system pressures would cause
concerns if the reading is correct
within several psi.
64
Repeated pressurization (especially
over-pressurization) of a gauge
does, however, tend to change the
response of the tube or diaphragm,
and re-calibration may be required.
The easiest way for a service
technician to re-calibrate a gauge is to
connect it to a source of known, pure
refrigerant, and then adjust the
re-calibration screw on the gauge to
the appropriate pressure reading based
on refrigerant temperature.
The most accurate way to re-calibrate
is to connect the gauge to a deadweight
tester at a re-calibration facility that has
equipment traceable to NIST. This is
usually cost-prohibitive for most
situations, but may be warranted when
total documentation is required.
LARGE 80 mm (3-1/8") DRY (°C) RED AND BLUE
with Class 1 (1% accuracy) calibration
YELLOW JACKET 68 mm (2-1/2") MANIFOLD
GAUGES (˚C) RED AND BLUE (Class B)
RIC
T
E
M
kg/cm2 and
psi
1/8" NPT Male
connection
Easy access
recalibration screw
(not covered by
boot)
NT
FRO RATION
ALIB
REC SCREW
Housed in a red or blue steel case for durability. Colored
temperature scales are easy to read through polycarbonate
crystal. Several features combine for improved accuracy:
Flutterless™ technology with brass surge protector to
minimize needle pulsation, brass gauge
movement,and copper alloy bourdon tube.
RIC
T
E
M
UPC#
Size
49131
49132
3-1/8"
3-1/8"
49135* 3-1/8"
49136* 3-1/8"
49143 3-1/8"
49144 3-1/8"
Description
Press. Scale Refrigerants
Red pressure
Blue compound
bar and psi
bar and psi
R-134a, 404A, 407C
R-134a, 404A, 407C
Red pressure
Blue compound
Red pressure
Blue compound
bar and psi
bar and psi
bar and MPa
bar and MPa
R-410A
R-410A
R-12, 22, 502
R-12, 22, 502
49145
49146
3-1/8" Red pressure
3-1/8" Blue compound
bar and psi
bar and psi
R-12, 22, 502
R-12, 22, 502
49153
49154
49163
49164
3-1/8" Red pressure
3-1/8" Blue compound
3-1/8" Red pressure
3-1/8" Blue compound
bar and MPa
bar and MPa
bar and MPa
bar and MPa
kPa and
psi
bar and
MPa
bar and
psi
All YELLOW JACKET gauges feature bold high-visibility dials
with color coded temperature scales for easy reading. And
Flutterless™ technology with surge protector minimizes the
needle pulsation for improved accuracy.
Compound gauges feature over-pressure protection to 350
pounds. 1/8" NPT Male lower mount fitting.
• Steel cases
• Class B (3-2-3% accuracy)
• Calibration traceable to NIST standards
UPC# Size
Description
Press. Scale Refrigerants
49003
49004
49005
49006
49025
49026
49027
49028
49031
49032
49033
49034
49035*
49036*
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
Red pressure
Blue compound
Red pressure
Blue compound
Red pressure
Blue compound
Red pressure
Blue compound
Red pressure
Blue compound
Red pressure
Blue compound
Red pressure
Blue compound
kPa and psi
kPa and psi
bar and psi
bar and psi
bar and MPa
bar and MPa
kg/cm2 and psi
kg/cm2 and psi
bar and psi
bar and psi
bar and psi
bar and psi
kg/cm2 and psi
kg/cm2 and psi
R-12, 22, 502
R-12, 22, 502
R-12, 22, 502
R-12, 22, 502
R-12, 22, 502
R-12, 22, 502
R-12, 22, 502
R-12, 22, 502
R-22, 134a, 407C
R-22, 134a, 407C
R-22, 134a, 404A
R-22, 134a, 404A
R-410A
R-410A
49053
49054
49055
49056
49057
49058
49059
49060
49063
49064
49010
2-1/2" Red pressure
2-1/2" Blue compound
2-1/2" Red pressure
2-1/2" Blue compound
2-1/2" Red pressure
2-1/2" Blue compound
2-1/2" Red pressure
2-1/2" Blue compound
2-1/2" Red pressure
2-1/2" Blue compound
Replacement crystal
bar and MPa
bar and MPa
bar and psi
bar and psi
kg/cm2 and psi
kg/cm2 and psi
MPa
MPa
bar and psi
bar and psi
R-410A
R-410A
R-134a, 404A, 507
R-134a, 404A, 507
R-134a, 404A, 507
R-134a, 404A, 507
R-134a, 404A, 407C, 507
R-134a, 404A, 407C, 507
R-134a, 404A, 407C
R-134a, 404A, 407C
bar and psi
bar and psi
bar and psi
bar and psi
bar and psi
bar and psi
bar and psi
bar and psi
R-134a, 404A, 407C
R-134a, 404A, 407C
49235*
49236*
49243
49244
49245
49246
49253
49254
49263
49264
49265
49266
49267
49268
49269
49270
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
Red pressure
Blue compound
Red pressure
Blue compound
Red pressure
Blue compound
bar and psi
bar and psi
bar and MPa
bar and MPa
bar and psi
bar and psi
R-410A
R-410A
R-12, 22, 502
R-12, 22, 502
R-12, 22, 502
R-12, 22, 502
Red pressure
Blue compound
Red pressure
Blue compound
bar and MPa
bar and MPa
bar and MPa
bar and MPa
Red pressure
Blue compound
Red pressure
Blue compound
Red pressure
Blue compound
bar and psi
bar and psi
R-410A
R-410A
R-134a, 404A, 407C
R-134a, 404A, 407C
R-12, 134a, 413A
R-12, 134a, 413A
R-22, 134a, 407C
R-22, 134a, 407C
R-22, 134a, 404A
R-22, 134a, 404A
UPC# Size
Description
Press. Scale
Refrigerants
49100
Replacement crystal
49183
4"
Red pressure
bar and psi
R-22, 134a, 404A, 407C
*These gauges have °C and °F on dial
49184
4"
Blue compound
bar and psi
R-22, 134a, 404A, 407C
bar and psi
bar and psi
bar and psi
bar and psi
GAUGES
49165 3-1/8" Red pressure
49166 3-1/8" Blue compound
49167 3-1/8" Red pressure
49168 3-1/8" Blue compound
49169 3-1/8" Red pressure
49170 3-1/8" Blue compound
Certified Gauges
49231 3-1/8" Red pressure
49232 3-1/8" Blue compound
R-410A
R-410A
R-134a, 404A, 407C
R-134a, 404A, 407C
R-12, 134a, 413A
R-12, 134a, 413A
R-22, 134a, 407C
R-22, 134a, 407C
R-22, 134a, 404A
R-22, 134a, 404A
*These gauges have °C and °F dials
LARGE 102 mm (4'') MANIFOLD GAUGES (°C) RED
AND BLUE with Class 1 (1% accuracy) calibration
Color-coded red for
pressure and blue
for compound
(not shown here)
Color-coded four
refrigerant types:
R-22, R-134a,
R-404A, R-407C
For all features see page 60.
65
LIQUID-FILLED 80 mm (3-1/8") MANIFOLD GAUGES (˚C) RED AND BLUE (Class B)
Large 80 mm diameter for easy
reading with refrigerants color-coded
on dials. Liquid-filled gauges calibrated
IC
R
T
ME
to Class B (3-2-3) accuracy and
feature a recalibrator screw. Rugged
case features beefed-up rings for
sealing reliability. Unique design
Gauge design
with 7˚ offset
stem will fit where
most 60 and
68 mm gauges fit.
allows gauge attachment to most
manifolds even where room is a
consideration. 1/8" NPT Male lower
connection.
UPC#
Size
49171
49172
49173
49174
49175
49176
49177*
49178*
3 -1/8"
Red liquid pressure
bar and MPa
3 -1/8"
Blue liquid compound
bar and MPa
3 -1/8"
Red liquid pressure
bar and MPa
3 -1/8"
Blue liquid compound
bar and MPa
3 -1/8"
Red liquid pressure
bar and MPa
3 -1/8"
Blue liquid compound
bar and MPa
3 -1/8"
Red liquid pressure
bar and psi
3 -1/8"
Blue liquid compound
bar and psi
*These gauges have °C and °F on dial
Replacement glycerine 6 oz.
Filler caps for liquid gauges
49095
49096
Description
Press. Scale
Refrigerants
R-12, 22, 502
R-12, 22, 502
R-134a, 404A, 407C
R-134a, 404A, 407C
R-410A
R-410A
R-410A
R-410A
MATCHING REFRIGERANT WITH A YELLOW JACKET GAUGE
Gases
UPC # Certified Size
Type
Color F/C
Scale
Gases
UPC # Certified Size
Type
Color F/C
Scale
12/134a/
413A
12/22/
134a
49165
49166
49013
49014
49083
49084
49103
49104
49001
49002
49008
49003
49004
49005
49006
49025
49026
49027
49028
49047
49048
49049
49081
49082
49101
49102
49143
49144
49145
49146
49171
49172
49063
49064
49071
49072
49131
49132
49151
49152
49163
49164
49173
49174
Steel
Steel
Steel
Steel
Liquid
Liquid
Steel
Steel
Steel
Steel
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
C
C
F
F
F
F
F
F
F
F
bar/psi
bar/psi
psi
psi
psi
psi
psi
psi
psi
psi
134a/
404A/
407C/507
134a/
404A/
507
49059
49060
2-1/2"
2-1/2"
Steel
Steel
Red
Blue
C
C
MPa
MPa
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Brass
Brass
Red
Blue
Red
Blue
Red
Blue
Red
Blue
C
C
C
C
C
C
C
C
F
F
kPa/psi
kPa/psi
bar/psi
bar/psi
bar/MPa
bar/MPa
kg/cm2/psi
kg/cm2/psi
psi
psi
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Brass
Brass
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
F
F
C
C
C
C
F
F
C
C
F
F
psi
psi
bar/psi
bar/psi
kg/cm2/psi
kg/cm2/psi
psi
psi
bar/psi
bar/psi
psi
psi
Liquid
Liquid
Steel
Steel
Steel
Steel
Steel
Steel
Liquid
Liquid
Steel
Steel
Liquid
Liquid
Steel
Steel
Steel
Steel
Steel
Steel
Liquid
Liquid
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
F
F
F
F
C
C
C
C
C
C
C
C
F
F
C
C
F
F
C
C
C
C
psi
psi
psi
psi
bar/MPa
bar/MPa
bar/psi
bar/psi
bar/MPa
bar/MPa
bar/psi
bar/psi
psi
psi
bar/psi
bar/psi
psi
psi
bar/MPa
bar/MPa
bar/MPa
bar/MPa
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
Set 49067/68
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
4"
4"
4"
4"
2-1/2"
2-1/2"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
Liquid
Liquid
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Liquid
Liquid
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Liquid
Liquid
Liquid
Liquid
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
F
F
F
F
C
C
C
C
F
F
C
C
C
C
F
F
F
F
C/F
C/F
C
C
C/F
C/F
C
C
C
C
C/F
C/F
psi
psi
psi
psi
bar/psi
bar/psi
bar/psi
bar/psi
psi
psi
bar/psi
bar/psi
bar/psi
bar/psi
psi
psi
psi
psi
kg/cm2/psi
kg/cm2/psi
bar/MPa
bar/MPa
bar/psi
bar/psi
bar/MPa
bar/MPa
bar/MPa
bar/MPa
bar/psi
bar/psi
12/22/
502
134a/
404A/
407C
66
49265
49266
49203
49204
49197
49198
49201
49202
49243
49244
49245
49246
49231
49232
49251
49252
49263
49264
3-1/8"
3-1/8"
2-1/2"
2-1/2"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
2-1/2"
2-1/2"
Set 49001/02
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
Set 49047/48
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
2-1/2"
2-1/2"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
49051
49052
49055
49056
49057
49058
22/134a/ 49015
404A
49016
49033
49034
49067
49068
49069
49079
49080
49105
49106
49169
49170
22/134a/
404A/407C
22/134a/
404A/410A
22/134a/ 49031
407C
49032
49167
49168
22/404A/ 49137
410A
49138
49179
49180
410A
49035
49036
49053
49054
49135
49136
49153
49154
49175
49176
49177
49178
49199
49200
49205
49206
49269
49270
49183
49184
49185
49186
49267
49268
49237
49238
49235
49236
49253
49254
YELLOW JACKET Electronic Instruments —
finding the facts needed
for the job
OVED
IMPR
™
AccuProbe Leak Detector
page 68
NEW
Refrigerant Analyzer
page 71
67
YELLOW JACKET ACCUPROBE™ LEAK DETECTOR –
heated sensor and Smart Alarm™ to find every leak fast and
1
1
6
99
sure, and know how big
Building on the field-proven original,
this improved unit is the only tool you
need for fast, easy, and certain leak
detection. The heated sensor tip of the
YELLOW JACKET® ACCUPROBE™ Leak
Detector positively identifies the leak source
for all refrigerants even those that other detectors
miss. That includes HCFCs such as R-22 as small as
0.03 oz./yr., HFC leaks of 0.06 oz./yr., even R-404A and
R-410A, and CFC – R-12 and R-502.
2-year limited warranty
(1-year warranty on sensor).
1 to 3 =
less than
0.1 oz/yr
4 to 6 =
0.1 to
0.5 oz/yr
7 to 9 =
more than
0.5 oz/yr
Lightweight for handling comfort.
LED Smart
Alarm™ Indicator
Low battery indicator
(4 AA alkaline)
Sensitivity levels
Audible alarm mute
Sensor not poisoned by large
amount of refrigerant and
does not need recalibration.
Sensitivity adjust
Made in USA
ON/OFF
Flashing
tip
Audible beeping
(can be muted)
Soft-touch grip
AC adapter jack
(adapter included)
18” reach
Frequency of flashes in the tip and
audible beeping increases the closer you
get to the leak source. You zero-in and
the exclusive Smart Alarm™ LED
shows how big or small the leak on a
scale of 1 to 9. Maximum value helps
you determine if the leak needs
immediate repair.
Service life of the replaceable heated
electro-chemical sensor is more than 300
hours with minimal cleaning and no
adjustments. Replaceable filters help
keep out moisture and dust that can
trigger false sensing and alarms.
Independent of the Smart Alarm LED,
the unit combines three sensitivity levels
with visual and audible signalling,
including ultra-high to detect leaks
that could be missed with other
detection systems.
68
• Position probe for close-up or
extended 18" detection
• Lightweight for handling comfort
• Replaceable filters help keep out
dust and moisture
• Sensor failure mode
• Automatic calibration
(no manual recalibration required)
• Leak Standard bottle of non-ozone
depleting chemical included to verify
proper functioning of sensor and
electronic circuitry
• 2-year limited warranty
(1-year warranty on sensor)
• Sensor not poisoned by large amount
of refrigerant
Unit is preset at normal sensitivity, but
you can switch to high or low. If there
is no response from the flashing tip or
beeping signal at normal sensitivity in
the general area of a suspected leak,
select high sensitivity. This will detect
even low levels in the general area and
confirm your suspicions. Use low
sensitivity as you move the tip over
more defined areas of a system, and
you will be alerted when the tip
encounters the concentration at the
leak source.
The frequency of flashing from the
heated sensor tip increases as you get
closer to a leak and refrigerant
concentration increases. You can also
turn on the audible alert. Beeping
increases in frequency and duration as
concentration increases.
Technology Comparison –
Heated Sensor or Negative Corona?
Tips for detecting system leaks
1. Inspect entire A/C system for signs
of oil leakage, corrosion cracks, or
other damage. Follow the system in
a continuous path so no potential
leaks are missed.
Heated Sensor Leak Detectors
When the heated sensing element is exposed to
refrigerant, an electrochemical reaction changes
the electrical resistance within the element causing
an alarm. The sensor is refrigerant specific with
superior sensitivity to all HFCs, HCFCs, and CFCs
and minimal chance of false alarms. When exposed
to large amounts of refrigerant which could poison
other systems, the heated sensor clears quickly
and does not need recalibration before reuse.
2. Make sure there is enough
refrigerant in system (about 15% of
system capacity or 50 psi min.) to
generate pressure to detect leaks.
3. Check all service access port fittings.
Check seals in caps.
Negative Corona Leak Detectors
4. Move detector probe at 1" per
second within 1/4" of suspected
leak area.
In the sensor of an old-style corona detector,
high voltage applied to a pointed electrode
creates a corona. When refrigerant breaks the
corona arc, the degree of breakage generates the
level of the alarm. This technology has good
sensitivity to R-12 and R-22, but only fair for
R-134a, and poor for R-410A, R-404A, and
R-407C. Sensitivity decreases with exposure
to dirt, oils and water. And false alarms can
be triggered by dust, dirt specks, soap bubbles,
humidity, smoke, small variations in the electrode
emission, high levels of hydrocarbon vapors, and
other non-refrigerant variables.
5. Refrigerant is heavier than air so
position probe below test point.
6. Minimize air movement in area to
make it easier to pinpoint the leak.
7. Verify an apparent leak by blowing
air into suspected leak to clean the
area and see if the leak remains..
8. When checking for evaporator
leaks, check for gas in condensate
drain tube.
Specifications
Max sensitivity :
0.06 oz. (1.7 g)/yr.
HFC’s R-134a
Max sensitivity :
0.03 oz. (0.9 g)/yr.
HCFC’s R-22
9. Use heated sensor type detector for
difficult-to-detect R-134a, R-410A,
R-407C, and R-404A.
Heated semiconductor
sensor: Over 300 hours life
Affected by humidity: No
Response time: Very fast
Body length: 10 inches (25.4 cm)
Probe length: 18 inches (46 cm)
Weight: 20 ounces (0.6 L)
Warm up time: 25 seconds or less
Battery type continuous life: 4 AA
alkaline, 8 hours
Operating temp. range: 24° to 110°F
(-4° to 43°C)
Storage temp range: -4° to 122°F
(-20° to 50°C)
UPC# Description
69365
69366
69367
69368
69378
69380
69381
69382
Heated AccuProbe
Heated AccuProbe European
Heated AccuProbe Japan
Heated AccuProbe Australia/New Zealand
(std w/69368) AC Adapter 230V/50-60 Hz
(std w/69365) AC adapter – 115V/60 Hz
(std w/69366) AC adapter – 230V/50 Hz
(std w/69367) AC adapter – 100V/50-60 Hz
Accessories and Parts
69383
69384
69385
69386
69387
69388
69389
Kit–sensor, filters and bottle
Replacement sensor and filter
Package 5 sensor filters
Leak sensor bottle
Carrying case with inserts
Carrying holster with clip
Battery cover and screw
Alarm
(with mute)
ELECTRONIC
INSTRUMENTS
Maintenance required: No
YELLOW JACKET COMBUSTIBLE
GAS DETECTOR –with ultrasensitive, long life sensor
Illuminated
bar graph
17" probe for extended reach
Made in USA
Hand-held precision equipment detects
all hydrocarbon and other combustible
gases including propane, methane,
butane, industrial solvents, and more.
See page 79 for details.
Approvals : SAE J1627, CE
69
YELLOW JACKET DIGITAL ELECTRONIC CHARGING SCALES
DIGITAL PROGRAMMABLE
CHARGING SCALE
• On-the-job convenience
with removable control
module on retractable
5 foot coiled cord
68802
• Water and environmental
resistance with sealed
LCD display and control
module touchpad
68803
• Industrial grade circuitry
for long life performance
• Mechanical overload
protection and “OL” alert
on LCD
• Minus (-) reading shows
weight removed from the
platform
• Eliminate charging
cylinders with a touch.
•
Large easy-to-read 0.5"
numbers even in brightly
lighted areas
•
"Low" battery icon on
LCD for 9V alkaline battery
• Save time with any
refrigerant in any system.
• Designed within UL
and CE guidelines
Model 68802 – 110 lbs. (50 kg)
9" x 9" (225mm x 225mm)
Model 68812 – 220 lbs. (100 kg)
12" x 12" (300mm x 300mm)
Put this rugged scale
to work with any refrigerant in any
system and eliminate the time and cost
of charging cylinders. The time-saving
process also eliminates refrigerant
transfer from tank to cylinder to
system. You weigh the refrigerant
container and charge directly into the
system or recover from the system.
No concern about residual refrigerant
in a charging cylinder.
Self-contained, the scale is ready to
use in the carrying case or removed
and set on a level surface. Select 110
or 220-lb. capacity (50 or 100 kg).
• Calibration standards traceable to
the National Institute of Standards
and Technology (NIST)
• Large heavy duty metal platform
and over sized strain gauge bridge for
rigidity, repeatability, and accuracy of
±0.5 oz., ±0.03 lb., ±0.015 kg, or
0.1% of reading, whichever greater
• Resolution 0.1 oz., 0.01 lb., 0.01 kg
70
• Measures pounds/ounces,
or pounds in decimal and kilograms
• Designed within UL and CE guidelines
Single point load cell strain gauge
for accuracy and long term stability
Full bridge configuration with
four strain gauges for accuracy
• Mesh filter in charging module
protects solenoid valve from debris
• Low flow triggers automatic hold
to extend solenoid life
• Schrader valve prevents
backflow through solenoid
• Charging accuracy is equal to
scale accuracy ±0.25 oz.
• Solenoid valve with 400 psi
maximum operating pressure
differential (MOPD) allows
metering broad range of
refrigerants
• •
•
•
Programmable charging scales have
the same features as at left but with
added capabilities for automated,
and even faster, more economical
charging. Simply enter the charging
weight on the control touchpad.
When weight has been dispensed,
scale automatically signals to shut-off
refrigerant flow.
••
Pocketed
electronics
for protection
• Durability of solid aluminum block
and largest strain gauge available
• IP66 protection from moisture
• Temperature compensated
• NIST traceable calibration
• NTEP approved
• Engraved with serial number for
QC tracking and assurance
Larger carrying case contains charging
module, control/programming
module, either a 110 or 220-lb.
capacity platform (50 or 100 kg),
and an AC power pack for solenoid
power during charging.
Convert scale to programmable
with upgrade kits 68804 and 68805
With one of these kits, standard 68802
or 68800 scales can be upgraded with
programmable charging capability.
Each kit includes a charging module,
power pack, instruction manual, and
larger carrying case to hold all parts.
Basic principle of
electronic charging scales
The cylinder and refrigerant in it
are weighed before and after
charging. The difference will be a
very accurate measurement of the
refrigerant used.
A digital scale shows the
progress of the charge as it is
happening so you know when to
close the valves and stop the
charge.
With the programmable scale,
you can also program the
stopping point so valves will
close automatically.
Compared to charging cylinders –
or especially bathroom scales or
hanging scales – the electronic
scale is faster, easier, safer, and
more accurate.
Scale Specifications 110 lb. scale
Operating temp: 32° to122°F (0° to 50°C)
Capacity: 110 lbs. (50 kg)
Storage temp: -4° to158°F (-20° to 70°C)
Resolution: 0.1 Ounce / 0.01 lb./
0.01 kg
220 lb. scale
Accuracy: ± 0.5 oz.
± 0.03 lb.
± 0.015 kg
}
Or 0.1%
of reading,
whichever
is greater
Total unit weight: 9 lbs. (4.1 kg)
Case Size: 15.5" L x 12.25" W x 3.25" H
(394 x 311 x 83 mm)
Capacity: 220 lbs. (100 kg)
Total unit weight: 12 lbs. (5.4 kg)
Case Size: 18" x 13" x 4.25" 457 x
330 x 108 mm)
Platform size: 12" x 12"
(304 x 304 mm)
UPC# Description
Module display: Sealed LCD with
high resolution 0.5" characters
68802
68812
68803
Keypad: moisture resistant membrane
keypad with tactile metal domes
68813
Components: Industrial grade
Operation method: Oversized strain
gauge bridge
Platform size: 9" x 9" (228 x 228 mm)
Battery: 25 hours (continuous use
approx.)
Battery: 9V alkaline
68800
68810
68801
68811
68804
68805
68806
68807
68818
Electronic scale 110 lbs. (50 kg)
Electronic scale 220 lbs. (100 kg)
Programmable electronic scale
110 lbs. (50 kg)
Programmable electronic scale
220 lbs. (100 kg)
Metric electronic scale 50 kg (110 lbs.)
Metric electronic scale 100 kg (220 lbs.)
Metric programmable scale
50 kg (100 lbs.)
Metric programmable scale
100 kg (50 lbs.)
Scale upgrade kit 115V
European upgrade kit 230V
AC power pack 115V
European power pack 230V
UK power pack 230V
YELLOW JACKET REFRIGERANT ANALYZER for speed, accuracy, and portability
• Quickly and
automatically
determines
purity of R-12
and R-134a to
help eliminate
potential of
human error
This portable unit delivers the features
and benefits professional A/C
technicians want for assurance, ease,
and profitability.
• Dispersive infrared (NDIR)
technology quickly determines the
weight concentrations of R-12,
R-134a, R-22, hydrocarbons and air
• Analytical software identifies all
EPA S.N.A.P. approved blends, as
well as illegal replacements and
blends including propane and butane
• Rechargeable battery lasts all day
Unit comes in a rugged portable case
with R-12 and R-134a sample hoses
Weight: 8.0 lbs.
Power requirements: 12VDC, via
battery clips (optional power
supply available)
Output: Digital display and LEDs,
Optional printer module
(internal)
Refrigerant: R-12, R-134a, R-22, HC,
and EPA S.N.A.P. approved
blends
Display: 128 x 64 Pixel Graphing
Resolution: 0.1%
Operating humidity: 0-95% RH
non-condensing
Operating temperature: 40° to 130°F
Built-in printer
runs an instant
receipt for
convenient and
accurate customer
billing. (68947)
Start to finish: 60 seconds
UPC #
Description
68945
68947
68948
Refrigerant analyzer
Refrigerant analyzer with printer
Optional internal rechargeable battery kit
with battery and 110 VAC charger
68949
Optional 110/220 VAC power adapter
71
ELECTRONIC
INSTRUMENTS
• Large
graphing
display is easy
to read
Specifications:
SuperEvac™ LCD VACUUM GAUGE –
Full range – atmosphere
to 1 micron
Compact design with storage
for sensor, cable and brass
connector.
YELLOW JACKET DELUXE LED
VACUUM GAUGE – AC powered
0.7" high
contrast digital
display for easy
reading.
5-1/2' coiled sensor cable
(straight cord with 69070)
Professional laboratory type is 100%
automatic instrument with .56" high
bright LED readout.
Battery operated. Instant ON.
Advanced technology uses
only one "D" cell.
• Thermocouple sensor technology
for precise and repeatable accuracy
• Improved software expands
sensing range from atmospheric
pressure to 1 micron.
69073 sensor
Impact
resistant
housing.
Replaceable thermocouple
sensor with 1/4" flare adapter
requires no calibration.
YELLOW JACKET LCD vacuum gauges
combine thermocouple sensor
technology with advanced electronics
for precise readings and repeatability
not found with thermistor sensors or
analog meters. The result - accurate
readings from atmosphere to 1 micron
without recalibration on job after job.
Thermocouple technology has long
been proven in laboratory and precision
industrial instrumentation for sensing
the deep vacuum range. Thermocouple
sensors are factory calibrated and
exhibit few of the electronic variances
of thermistor sensors found in many
other electronic gauges.
Thermocouple sensor features:
• No adjustments or warm-up.
Stays calibrated after on/off
switching and long evacuations.
• Automatic battery compensation
• Automatic ambient temperature
compensation
LCD gauge features:
• Normal handling and jarring
will not affect the LCD reading
• Rugged molded case protects
electronic circuitry and sensor
• Calibration standards traceable
to (NIST)
72
69071 connector
• Precision circuitry controls
sensor and translates sensor
input into micron readings on
the easy-to-read LCD
Specifications
Response time:
Calibration:
Warm up:
Sensor cable:
Sensor
connection:
Operating
temperatures:
Power:
Battery life:
3 seconds
Automatic
3 seconds
5.5 feet (167 cm)
coiled
1/4" Male flare
32° to 120°F
(0° to 49°C)
1 "D" cell battery
70 hrs continuous
Battery check: On LCD display
Dimensions:
9" x 12.25" x 2.37"
(230 x 310 x 60 mm)
Accuracy:
± 20% of reading
UPC #
Description
69071
69073
1/4" brass Female flare connector
Replacement sensor
for 69070, 69075
SuperEvac LCD vacuum gauge
full range complete in case
(atmosphere to 1 micron)
Optional ball valve to add to sensor
1/8" NPT Female x 1/4" Female flare
69075
69067
19110
Optional coupler to add to sensor
1/8" NPT Female x 1/4" Female flare
• Calibration standards traceable
to (NIST)
Complete unit includes aluminum LED
display unit, sensor with valve, cable,
brass connector and carrying case.
Specifications
Response time:
Calibration:
Warm up:
Sensor cable:
Sensor
connection:
Operating
temperatures:
Storage
temperatures:
Power:
3 seconds
Automatic
3 seconds
9 feet (274 cm)
1/4" Male flare
with isolation valve
-30° to 150°F
(-34° to 65˚C)
-30° to 160°F
(-34° to 65°C)
115V 60 Hz
(230V available)
Power cord:
6 feet
Dimensions:
4.25" x 5.5" x 1.5"
(108 x 140 x 38 mm)
Carrying case: Heavy duty plastic
12.25" x 8" x 3.5"
(310 x 203 x 89 mm)
UPC #
Description
69060
LED vacuum gauge kit
complete with case, 115V
LED vacuum gauge kit
complete with case, 230V
Sensor for 69060 and 69063
9' sensor cable for above
69063
69064
69065
69066
Carrying/storage case
69067
Ball valve for sensor
1/8" NPT Female x 1/4" Male flare
69071
1/4" brass Female flare connector
15006
Optional vibration isolation hose
YELLOW JACKET DIGITAL VACUUM GAUGE with seven different units of vacuum
clean and performing
properly. If the sensor
gets dirty, simply pull
a new sensor out of
your tool kit, plug it
into the gauge, run
through a quick calibration process, and
be back on the job within minutes.
• Unique patented thermal conductivity
sensor automatically compensates for
temperature
This easy-to-use gauge helps you to
be certain that air and moisture have
been removed from the system. Simple
push of a button changes the display
readout between 7 units of vacuum.
Each displays down to the equivalent
of 10 microns of vacuum to let you
know that your vacuum pump is
• Replaceable, cleanable, plug-in
sensor (Part #69087) handles 450 psi
positive pressure
• Displays 7 different units of vacuum
(microns, milliTorr, Torr, millimeters
of mercury, millibar, kiloPascal and
Pascal)
• Calibration standards traceable to (NIST)
• 12" coiled sensor cord stretches to
24" for easy reach, connectivity, and
readability of display
• Low battery indicator
• Automatic shut-off after 20 minutes
• Operating Temperature Range:
32° to 122°F (0° to 50°C)
• Weight: 12 oz. (340 g) with battery
• Battery Life: Approximately
25 hours continuous use
UPC #
69086
Description
69087
69088
69089
Hand-held vacuum gauge with
fabric carry pouch
Replacement sensor
Replacement cable
Battery cover (blue)
69090
69091
Accessory case
Replacement fabric pouch for 69086
YELLOW JACKET DIGITAL LCD ECONOMY VACUUM GAUGE
What is an “adequate” vacuum,
and how do I measure it?
Versatile — Connect to the YELLOW JACKETD SuperEvac™ Vacuum
Pump, or in line with a tee fitting, or directly to the system with
YELLOW JACKETD core removal tool 18975 at right (and see page 21).
• Unique thermal conductivity
sensor automatically compensates
for temperature with no calibration
• Simple On/Off controls
• Automatic battery saver shuts
gauge off after 20 minutes with
no reading changes
• Low battery indicator
• Calibration standards traceable to
the National Institute of Standards
and Technology (NIST)
• Patented technology
Packaged complete with 9V alkaline
battery and hanging hook
• Easy-to-clean sensor handles
450 psi positive pressure
UPC #
• Rugged construction with tough
ABS housing and solid state circuitry
for accuracy
69081
69079
69080
Description
Digital LCD vacuum gauge with battery,
hook
Optional soft-sided protective case
Replacement battery door and screw
1000 microns equal only .039
inches of mercury, a measurement
that cannot be made with a
mechanical gauge, or determined
by evacuation time or the sound of
the pump. The only tool that can
measure vacuum at these levels is
an electronic vacuum gauge.
ELECTRONIC
INSTRUMENTS
For peace of mind, this gauge shows
you that air and moisture has been
removed from the system. The lower
the number of microns, the more
complete the vacuum and less chance
for no-charge call-backs. Track down
14 increments from atmosphere to
25 microns to know that the system
is clean and your vacuum pump is
performing properly.
ASHRAE recommends evacuation
to below 1000 microns, and after
isolation a system must not rise above
2500 microns within several hours.
Some equipment manufacturers
specify deeper vacuum such as 400
microns to ensure that harmful water
vapor is removed from the system.
The best place to measure vacuum
is at the system, not at the pump.
With a combination vacuum/
charging valve, you can attach the
gauge directly at the system and
isolate it from the pump, hoses and
manifold for a true indication of the
vacuum in the system. You can see
the last evidence of moisture being
removed and know that the system
has dried out.
73
YELLOW JACKET PISTOL-GRIP INFRARED
THERMOMETER –
-40°F to 932°F
YELLOW JACKET INFRARED THERMOMETERS
69240
One 9V
battery
included.
69235
Pocket-size – compact and lightweight.
With wide measurement of -40° to
932°F, this easy-to-use tool is the
effective choice for high or low temp
and refrigeration applications. For
accuracy and
resolution, the
focal point is a
tight 10:1 ratio
with laser
sighting.
• Selectable 3-point emissivity for
simple set-up
• Backlight for dark area use
• °F/°C switchable
• ± 2% or 2°C accuracy
• 0.1°F resolution at -40° to 212°F
(-40° to 100°C)
With laser sighting, you simply target a
surface and press the power key to take
a fast and safe non-contact temperature
reading. 95% response in 500 msec at
-4° to 788°F (-20° to 420°C). To take
readings in low light, the large LCD
features a switchable backlight.
FEATURE
69235
MODEL
69237
69240
Accuracy
±5.4°F, ±3% ±3°C, ±3% ±3.6°F, ±2%
Emissivity
Fixed
Fixed
adj. 0.3-1.0
Distance/
8:1
8:1
8:1
Spot ratio
Switchable
°F only
°C only
Yes
Max/Min
No
No
Yes
Delta T/Avg
9 pt. memory
No
No
Yes
Audio alarm
No
No
Yes
Keys
3 Keys
3 Keys
5 Keys
Dimension
6-1/8" x 1-5/16" x 2-1/8"
(156 x 33 x 53 mm)
Weight
6.3 oz. (180 g)
Measurement capabilities 69240:
• Real time temp of surface measured
• Highest and lowest temperature taken
• Average temperature from the time
the power key was first pressed
• Determines net temp difference
between two surfaces or readings of
the same surface to calculate net
heating or cooling
UPC #
Description
69235
Infrared thermometer – °F
69237
Infrared thermometer – °C
69240
Full feature infrared thermometer
YELLOW JACKET ® MICRO INFRARED THERMOMETER
• Fast response time of 500 ms
UPC #
69228
Description
Pistol-grip infrared thermometer
Applications
• HVAC/R
• Plastic molding
• Automotive
• Road
construction
• Plant
maintenance
• Laboratories
• Energy
auditing
• Food service
• Electrical
74
At 2.7" x 1.5" x
.7" and 0.9 ozs.
(1.1 oz.
w/battery),
this is the most
compact infrared
thermometer
available. Quickly
measures -27° to 428°F (-33° to 220°C)
with distance to spot ratio of about 1:1.
• ±2% of reading or 4°F (2°C),
whichever is greater
• Operating temp. range: 14° to 122°F
(-10° to 50°C)
• Emissivity: 0.05-1 adjustable
• Wave length: 5-14 microns
• Maximum and Minimum hold
• °F/°C switchable
• Resolution: .1°F or C
• Fast response time of 0.5 second
• 3V button cell battery included
(CR2032)
UPC #
Description
69225
Micro infrared thermometer
YELLOW JACKET DIGITAL THERMOMETERS
Differential and single probe types
YELLOW JACKET WATER-PROOF DIGITAL
THERMOMETER –
Single probe “K” type
Easy strap-on probe
for 1/4" OD and
larger piping.
Efficient for super
heat. Part 69224.
Easy-to-use
single “K”probe
unit meets IP66
standard. First 6
means that the
unit is dust tight.
Second 6 means
that the unit is
“protected
against powerful
water jets” from
any direction
with “no
harmful effects.”
F
A
B
C
D
E
Specifications
Range:
Single Probe “K” type features:
Resolution:
-58° to 1999°F
(-50° to 1300°C)
1 or 0.1 degree
Display:
LCD 5/8" (16 mm)
Operating temp: 32° to 120°F
(0 to 49˚C)
• Auto-ranging resolution .1 and 1°
Storage temp:
-20° to 130°F
(-29 to 54°C)
• Backlight for dark area use
Power:
9 volt alkaline
battery
• °F/°C switchable
Battery life:
Approximately
200 hours
continuous
Specifications
• Single “K” type input
• Switchable °F and °C. -58° to
1999°F (-50˚ to 1300°C)
• Resolution is switchable 0.1° and 1°
• Max/min/relative reading memory
• Sleep mode on/off
• Max/Min and hold temperature
readings
Dimensions:
• Low battery indicator
Accuracy:
• Power off after 30 minutes
-58° to 1800°F ± (0.3% of reading + 2°F)
-50° to 982°C ± (0.3% of reading + 1°C)
Differential “K” type added features:
7.2" x 2.75" x 1.6"
(180 x 70 x 40 mm)
• Dual “K” type thermocouple input
• Resolution 1°
-328° to 1999°F
(-200° to 1300°C)
Operating temp: 32° to 122°F
(0° to 50°C)
(0-85%RH, non-cond)
Sampling rates: 2.5 per second
Battery:
9 volt, battery life
200 hours
Display:
1.5" x 1.7"
(37 x 42 mm)
LCD, maximum
reading 1999
Dimensions:
7.1" x 2.8" x 1.2"
(181 x 71 x 30 mm)
Thermometer applications:
HVAC/R technicians, research,
industrial process laboratory.
UPC #
Description
69200
Digital thermometer — single general purpose probe and case
69205
69207
Differential thermometer — 2 clamp on, 2 general purpose probes and case
Differential digital thermometer — 2 strap-on, 2 general purpose probes and case
69210
Differential thermometer — two general purpose probes and case
UPC #
Description
69215
69216
69218
69220
69222
Type “K” air probe
Type “K” clamp-on probe
Type “K” general purpose probe
Type “K” surface probe
Type “K” puncture probe
69224
Type “K” strap-on probe
Accuracy:
Max. Temp.
Length
Response
time (sec.)
(E)
(A)
(C)
(B)
(D)
1100˚F (593˚C)
1100˚F (593˚C)
500˚F (260˚C)
1650˚F (900˚C)
570˚F (299˚C)
4 ft.
4 ft.
3 ft.
4 ft.
4 ft.
(1.21 m)
(1.21 m)
(.91 m)
(1.21 m)
(1.21 m)
5
12
3
3
12
(F)
300˚F (149˚C)
12 ft. (3.65 m)
12
-200° to 1300°C ± (0.3% rdg + 1°C)
1000° to 1300°C ± (0.5% rdg + 1°C)
-328° to 2372°F ± (0.3% rdg + 2°F)
(18° to 28°C ambient temperature)
UPC #
69233
Description
Waterproof thermometer –
single “K” probe
75
ELECTRONIC
INSTRUMENTS
• T1, T2, or T1-T2 differential readings
Range:
YELLOW JACKET
DIGI-ALARM THERMOMETER
POCKET DIGITAL THERMOMETER YELLOW JACKET SUPERHEAT
CALCULATION KIT
Digital head rotates
180° for easy reading.
• On/off button
Extended
reach
stainless
steel
probe.
• Auto shut-off after
10 minutes to save
battery
• Reading updates
every second
• 5" (125 mm) stem
This compact unit
measures from
-58° to 392°F
(-50° to 200°C)
and triggers an
alarm at the
high and low
temperatures
that you’ve
programmed.
UPC # Description
Case/
Qty.
69107
Thermometer - 58° to 302°F
digital (- 50° to 150°C)
69250 60107 display pkg.
69110 Battery
1
12
With the access valve, improved
˚F and ˚C digital thermometer and
core extractor tool you can easily take
an internal temperature reading for
calculating system superheat.
• Read from -58° to 302°F (-50°
to 150°C), and pressure
• Extract Schrader core without
opening system
POCKET THERMOMETERS
• Remove broken Schrader cores
• Maximum/minimum temperature
memory
• Chase damaged threads
• °F/°C switchable
• Use as vacuum valve to increase
flow and reduce vacuum time. Also
can decrease charging time
• Data hold function
• Key tone for operation confirmation
• No calibration
• Foldaway stand
• Automatic self test after battery
installation
• Replace cores
1" and 1-3/8" dial thermometers are
adjustable with a 5" stainless steel
stem. Colored sheath
with pocket clip.
• Use to reduce recovery time
• Individually
calibrated.
• Shock resistant.
Specifications
Accuracy:
±1°C between -50° to 150°C
otherwise ±4°C
±2°F between -58° to 302°F
otherwise ±8°F
Display resolution:
0.1° over the full range
Sampling rate: 1 second
Battery:
1.5 volt size AAA/UM4 or
equivalent (1 piece included)
Ambient temperature:
14° to 122°F
(-10° to 50°C)
UPC #
Description
69239
Digi-alarm thermometer
76
Packaging:
12 units with
display
UPC # Description
69251
69252
69253
69255
1" dial 0° to 220°F
1" dial 40° to 160°F
1" dial 50° to 550°F
1-3/8" dial -40° to 160°F
(-40° to 70°C)
69256 1-3/8" dial 0° to 220°F
(-10° to 110°C)
69265 1" dial 0° to 70°C
Applications
• Food
processing
• Heating and
ventilating
• Agriculture
• Laboratories
18979
Case/
Qty.
•
•
•
•
12
12
12
12
12
12
Industrials
Refrigeration
Pharmaceutical
Brewing
18978
Accessory Set 18980
UPC #
Description
69104
Complete Superheat Kit and
Accessories (as shown)
69103
Superheat Kit w/o accessory kit
18975
Improved Vacuum/Charge Valve
18980
Accessory Set - 2 piece
18978
Schrader Rethreading Accessory
18979
Broken Schrader Remover
Accessory
69106
Digital Thermometer and Nut
- 40° to 230°F
69107
Pocket Thermometer
18997
Grappler rod and nut assembly
YELLOW JACKET HYGRO-THERMOMETER
SOUND LEVEL METER
This easy-to-use unit
measures and displays
30-130 decibels digitally
and as an analog graph to
help you test for OSHA
compliance, monitor
equipment, and more.
• Meets IEC 651, ANSI S1.4,
Type 2 standard
• Six measurement ranges in 10 db
increments
• Max/Min and Max Hold functions
Specifications
As indoor air quality and environmental
issues gain in importance, instruments
to accurately measure temperature and
relative humidity are essential. The
YELLOW JACKET hygro-thermometer is
a highly accurate industrial grade meter
that measures both humidity and
temperature for the AC&R industry as
well as heating and ventilation.
Features include:
• Microprocessor controlled for
reliability and repeatability
• Wide temperature and humidity
range
• Using temperature only probe –
139° to 392°F (-95° to 200°C)
• Industrial grade components.
• Calculates and displays dew
point in °F or °C
Accuracy: ± 2.0% RH. ±0.3% of temp
reading ±1 digit
Accuracy: ±1.5dB (under reference
condition)
Digital display: 3-1/2 digit LCD, 0.1dB
resolution updated 0.5 seconds
Analog output: AC: 0.707 vrms (at full
scale) DC: 10mV/db
Measurement frequency range:
31.5Hz - 8KHz
Power: 9V battery (included)
Dimension: 3.1" W x 10" H x 1.5" D
(80 x 256 x 38 mm)
Resolution: ±0.1% RH. 0.1°F or °C
UPC# Description
Specifications
Range: %RH 5.0 to 95% RH
-4° to 176°F (-20° to 80°C)
Range: using separate 68855
temperature only probe -139° to 392°F
(-95° to 200°C)
Response time: RH – up to 90% of
change is measured value in 15 seconds.
Temperature – approximately 60 seconds
Temperature drift: ±0.5% RH per
18°F (10°C)
Display: LCD 0.5" x 4 digits (15 mm)
Operating temperature:
Instrument: 32° to 122°F (0° to 50°C)
Probe: -4° to 176°F (-20° to 80°C)
Power: 2 AA alkaline battery
• Switchable from °F and °C
Battery life: approx. 300 hours
• Display “hold” function for operator
ease
Battery check: low battery on
LCD display
• Replaceable sensor probe
Dimensions: 7 .1" x 3" x .8"
(181 x 71 x 20 mm)
Probe 1" diameter (25 mm)
• Long battery life of approximately
300 hours
Applications: HVAC/R technicians,
clean rooms, hospitals, computer
rooms, laboratories, warehousing,
pharmaceuticals.
Weight: 8 oz. (.22 kg) with batteries
UPC #
Description
68850
Hygro-Thermometer complete
with probe, batteries and case
68854
Replacement relative
humidity/temperature probe
68855
Temperature only probe -139° to
392°F (-95° to 200°C)
Deluxe sound meter
YELLOW JACKET TACHOMETER
Easy-to-use and read unit measures 10
to 99,999 rpm on compressors, fans,
motors, gears, pulleys, and more. Noncontact reading maintains torque and
precise measurement.
• Auto range function
• Units in rpm
ELECTRONIC
INSTRUMENTS
• Maximum and minimum
temperature and humidity readings
69346
• Hold function to freeze
rotating speed
• Readings to a resolution
of 0.001rpm
Specifications
Time base:
4.0 MHz quartz crystal
Power:
9V battery (included)
Sampling time: 1 second (>60 rpm,
10 to 60 rpm)
Dimension:
4.8" L x 1.9" W x 1.3" H
(124 x 50 x 33 mm)
UPC# Description
69348
Non-contact photo tachometer
77
YELLOW JACKET DIGITAL ANEMOMETER
YELLOW JACKET ANEMOMETER
Flexible
Over 4 feet
of extension
rods
Extended reach
Complete kit
68900 shown
Precision industrial grade instrument
for air conditioning, refrigeration,
heating and ventilation. Measures air
velocity and calculates air flow
volume. Features include:
• Reads air velocity from
40-7800 fpm
• Probes have metal vanes and high
quality bearings for durability.
Balanced to work reliability at
-4° to 210°F (-20° to 99°C)
• Probes calibrated before
leaving factory. Replaceable and
recalibrateable
• Extension handles and 5 foot
cable for hard-to-reach areas
• Microprocessor controlled for
reliability and repeatability
• Calculates and reads in cfm
(cubic feet/minutes) or cmh
(cubic meters/hour)
• Switchable imperial to metric
measurements
• Memory saves minimum and
maximum readings
• Averages reading over 2 or
16-second periods
• Display “hold” button
Applications: Balancing air
conditioning and heating ducts,
refrigerated cases, check fan and
blower operations, automotive,
meeting safety regulations.
78
Specifications
Air flow:
Probe 68904 40-7800 fpm
(0.2 to 40.00 mps)
Probe 68905 60-6800 fpm
(0.3 to 35.00 mps)
Calc. Air Vol. 0.0 to 9999 cfm
(0.0 to 9999 cmh)
(cubic meter/hr.)
This hand-held instrument reads
both air velocity and temperature
simultaneously when balancing air
conditioning/heating ventilation
systems.
Features:
• Low cost
• Microprocessor controller
• Calculates cfm air volume
• Records minimum and
maximum readings
• Averages air velocity
Accuracy:
±1% of reading
±1 digit
Resolution:
1 fpm (0.01 mps)
• Display “hold” button freezes
LCD reading
Display:
.5" LCD 4 digits
• Switchable imperial to metric
Operating
Instrument:
32° to 122°F (0-50°C)
• RS232 output
-4° to 212°F
(-20° to 100°C)
Specifications
Probe:
• Auto power off after 20 minutes
Power:
2 AA alkaline batteries
Battery life:
Approx. 300 hours
Battery check: Low on LCD display
Dimensions :
Inst.
68904
68905
7.1" x 3.0" x 0.8"
(180 x 76.2 x 20.3 mm)
2-7/8" (70 mm) dia. probe
1.0" (25 mm) dia. probe
Air flow ranges: 125 – 4900 ft/min
Resolution: 1 ft/min and 0.01 m/sec.
Accuracy: ±2%
Temperature: 14° to 122°F
(-10° to 50°C)
Resolution: 0.01°F and 0.1°C
Accuracy: ±1.0°F (±0.6°C)
Power: 9V/100 hr. average
UPC #
Description
68900
Complete Kit 2.75” dia. Probe
68901
Complete Kit 1.0” dia. Probe
UPC #
Description
68904
68905
Probe 2.75” dia. Vane type
Probe 1.0” dia. Vane type
68915
Anemometer kit
68916
68906
5' extension cable
Replacement 2.75" (70 mm)
diameter probe assembly
68907
10” extension rod
68908
10” flexible extension
Fan Diameter: 2-7/8" (70 mm)
YELLOW JACKET COMBUSTIBLE GAS DETECTOR –
with ultra-sensitive, long life sensor
DIGITAL SLING PSYCHROMETERS
THERMO HYGROMETERS
Pocket-sized
to carry on
every call.
Set systems
at specific
superheat or
subcooling
temperatures.
Use actual
wet and
dry bulb
measurements
and factory
charts.
Illuminated bar graph
Alarm (with mute)
17" probe for extended reach
Made in USA
Hand-held precision equipment detects
all hydrocarbon and other combustible
gases including propane, methane,
butane, industrial solvents, and more.
Sensitivity, bar graph, and beeping
to signal how much and how close
Unit is preset at normal sensitivity,
but you can switch to high or low.
After warm-up you’ll hear a slow
beeping. Frequency increases when a
leak is detected until an alarm sounds
when moving into high gas
concentration. The illuminated bar
graph indicates leak size.
• Ultra-sensitive sensor detects less than
5 ppm methane and better than 2 ppm
for propane. Performs equally well on
a complete list of detectable gases
including acetylene, butane, and
isobutane.
• Gas lines/pipes
• Propane filling
stations
• Heat
exchangers
• Marine bilges
• Data hold
• Auto power off
• Gas heaters
• Manholes
• Display relative humidity and
temperature simultaneously
• Combustion
appliances
• Air quality
Specifications
• Arson residue
(accelerants)
Temperature
Range: -4° to 122°F (-20° to +50°C)
Size:
7'' H x 1-7/8'' W x 1'' D
178 H x 48 W x 25 mm D
Sensors: Temperature: thermistor bead
Humidity: polymer
film (capacitance)
Batteries: 2 standard AAA
Operating
range: +4° to +122°F
(-20° to +50°C) 0-100% RH
Resolution: 0.1°F/C, 0.1% RH
Accuracy:
Relative humidity functions
(± 3% RH at 25°C)
Temperature ± 1°F (0.6°C)
Auto-power-off: 5 min. (defeatable)
Response time: Approx. 60 sec.
Update Rate: 2-6 sec. depending on
function
Weight:
2.65 oz. (75 g)
• Hydrocarbon
refrigerant
Specifications
Response time: Instantaneous
Warm up time: 10 seconds
Power:
4 AA alkaline
batteries
Probe length:
17 inches (43.17 cm)
Sensor life:
500 hours
Body length:
10 inches (25.4 cm)
Weight:
20 ozs. (0.57 kg)
Battery life:
20 hrs. continuous
Operating
temp. range:
Approvals:
32° to 110°F
(0° to 43.3°C)
Intrinsic Safety, CE
ELECTRONIC
INSTRUMENTS
If no leak is detected in an area you
suspect, select high sensitivity. This
will detect even low levels in the area
to confirm your suspicions. Use low
sensitivity as you move the tip over
more defined areas, and you will be
alerted when the tip encounters the
concentration at the leak source.
• Display
°F or °C
Applications
• Automatic calibration and zeroing
• Long life sensor easily replaced after
full service life
• 2-year limited warranty
• And many more features
UPC# Description
UPC #
Description
69373
69301
69371
69379
69387
69388
69008
Digital thermo psychrometer
Combustible gas detector w/case
Sensing tip
Replacement sensor
Battery cover red and screw
Carrying case – blow molded
Carrying holster
Sling Psychrometer on next page.
79
YELLOW JACKET SLING PSYCHROMETER
conversion of readings to relative
humidity percentage.
• One piece unit self-contained
housing fits into your pocket
Streamlined, compact tool
measures wet and dry bulb temperatures
of surrounding air for immediate
UPC #
Description
69010
Sling psychrometer
• Calibrated and easy-to-read
69011
Replacement wicks (5 pack)
• "Slide rule" scale is part of the case
69015
Replacement thermometer
YELLOW JACKET DIGITAL ELECTRONIC MANOMETER
The unit
benefits all
contractors
who wish to
eliminate the
mess and
fragility of
U-tubes or
diaphragm type
gas pressure
gauges. This
easy to use
electronic
instrument
provides a
continuous
display of the
measured
positive or
negative
pressure. The
unit provides
• Accurate to 1% of "Hygrometric
Tables"
measurements from -19.95" to +19.95"
water column. Ideal for setting gas
pressure at manifold, also check pressure,
flue draft and air balancing. Once your
work is complete it automatically turns
itself off. Kit includes battery, tubing, and
brass fitting.
YELLOW JACKET WATER-TYPE
MANOMETER
• -19.95" to +19.95" water gauge
• 0.05" WG resolution
• Easy to use
• Large LCD display
• Automatic power-off
Economical plastic tube manometer
helps you set manifold pressure for
natural or L.P. gas. Now goes to
-2" W.C. for newer systems.
• Long battery life
Strong magnet on manometer holds it
in convenient upright position.
• Includes 18" tubing and fitting
Includes tubing with fitting.
UPC# Description
UPC #
Description
78050
78051
78071
59511
78070
78075
-2" - 0 - 7-1/2" scale manometer
-2" - 0 - 15" scale manometer
78071
Tubing with fitting
59511
Brass fitting only
Digital electronic manometer
Battery door
Tubing with fitting
Brass fitting only
YELLOW JACKET GAS PRESSURE TEST KIT
diaphragm (bellows) to brass plate
withstands higher over-pressure.
Original
Improved
Double bellows
Single bellows
• Tube nipple for easy connection
to system manifold
• Two gauge ranges available
UPC#
Easier to use than a manometer, this
compact kit helps you accurately set
manifold pressure for natural or L.P. gas.
• Sensitive diaphragm gauge calibrated
in inches of water column
• Improved lamination strength of
80
Description
78055
78056
Complete test kit – 0-10" W.C.
Barb-fitting gauge – 0-10" W.C.
78057
78060
78061
78066
78062
1/4" NPT Male gauge – 0-10" W.C.
Complete test kit – 0-35" W.C.
Barb-fitting gauge – 0-35" W.C.
1/4" NPT Male gauge – 0-35" W.C.
Hose with nipple
78064
78065
78059
78063
Brass barb-fitting
Rubber nipple
Gauge crystal
Carrying case
The unique single bellows on brass plate design
replaces the double bellows for a stronger seal
that resists greater over-pressure.
GLASS MIRRORS —telescoping
All mirrors
have
telescoping
feature.
Some have
clips for
pockets and
magnifying
glass.
Replaceable
mirrors.
UPC #
Description
78094
78097
2-1/4" round
2-1/4" round
magnified
Heavy duty
plastic case.
78103
78104
efficiency. Kit includes 2" gauge, 30"
0-150 lbs. scale, and 12" YELLOW
JACKET hose with fittings.
UPC #
Complete kit to determine pump
efficiency, cut-off, suction etc. Also
use to analyze or trouble shoot burner
Description
78020
Complete fuel oil gauge kit
78021
2" fuel oil gauge only
78023
Carrying case
78011
12" hose – no valve opener
78024
Fitting set (4)
78031
2-1/2" gauge, scale 30", 0-150 lbs.
78032
2-1/2" gauge, scale 30", 0-300 lbs.
All gauges are 1/8" NPT.
Extension
9-1/4" to 14-1/2"
9-1/4" to 14-1/2"
With pocket clip and insulated head
78098
78099
FUEL OIL TEST KIT
1-1/4" round
1-1/4" round
magnified
2-1/8" x 3-3/8"
rectangular
1" x 2" oval
7" to 27"
7" to 27"
OIL PUMP VIBRATION ELIMINATOR
Reinforced rubber hose helps eliminate
noise and vibration when installed in a
heating system.
11" to 15-1/2"
• 1250 psi (86 bar) min. burst, 250 psi
(17 bar) max. working pressure
• Operating temperature -20° to 180°F
(-28.8° to 82.2°C)
12 inch OA
7" to 19"
Replacement mirrors only
78105
2-1/4" round glass
78106
2-1/8" x 3-3/8" rectangular glass
78107
1" x 2" oval glass
UPC #
Description
Fittings
78012
Oil burner connector
3/8" Male flare x 1/4" NPT Male
GAS TEST GAUGE — 1/2", 3/4"
and 1" pipe
INSPECTION MIRRORS —
stainless telescoping
Mirror
rotates 360°
Check leaks in hard to see places.
Stainless steel mirror on ball joint
rotates 360˚. Handle telescopes to
28".
UPC #
Description
78100
Round 3-3/4" diameter
78101
Rectangular 3-3/4" x 2"
78102
Rectangular 2" x 1-1/4"
UPC # Description
78076
78077
78080
78087
Test unit 0 - 15 lb. gauge 1/2" end
Test unit 0 - 15 lb. gauge 3/4" end
Test unit 0 - 30 lb. gauge 3/4" end
Test unit 0-60 lb. gauge 3/4" end
78090
78078
78081
78091
78079
Test unit 0 - 100 lb. gauge 3/4" end
Gauge 1/4" NPT Male 0 - 15 lb.
Gauge 1/4" NPT Male 0 - 30 lb.
Gauge 1/4" NPT Male 0 - 100 lb.
Test unit 0 - 15 lb. gauge 1" end
78085
78095
78096
Test unit 0 - 30 lb. gauge 1" end
Test unit 0 - 100 lb. gauge 1" end
Schrader fitting 1/8" NPT Male x tire fitting
Larger 3-1/2" gauges are easier to
read. Scale in psi and bar. Brass
threaded bell for leak tight connection.
UPC # Description
78084
78086
78088
78089
49382
3-1/2" test unit 0-30 3/4" pipe
3-1/2" test unit 0-100 3/4" pipe
3-1/2" test unit 0-30 1" pipe
3-1/2" test unit 0-100 1" pipe
Gauge only 2-1/2" test unit 0-60 lb.
49421
49424
Gauge only 3-1/2" test unit 0-30 lb.
Gauge only 3-1/2" test unit 0-100 lb.
81
ELECTRONIC
INSTRUMENTS
Extend to 28"
Easy-toread gauge
to test
system
pressure for
leaks in
new
Brass bell
installations.
Pressure drop on 2" gauge indicates
leakage. 0-30 gauge is in 1/4 lb.
increments and 0-15 is in 1/5 lb
increments to meet some local
inspection regulations.
YELLOW JACKET GAS TEST –
3/4" and 1"– with 3-1/2" gauge
TEST LEAD SETS
Set of two leads three feet in length.
Clips with red and black insulators
each end. 120/240V – AC.
UPC #
69532 & 69531 use 16-1 wire.
69530 & 69529 use 14-1 wire.
Product Information
Max Amps
Clip Size
69532
69531
69530
5 Amp
10 Amp
10 Amp
Small
Medium
Medium
Annie T-16-1 & HI TL1
Annie T-16-2 & HI TL2
Annie T-14-2 & HI TL3
Replaces
69529
20 Amp
Large
Annie T-14-3 & HI TL4
TEST LEAD SETS
Clips with red and black insulators
other end.
A six-foot lead using number 16-2
wire and male plug one end.
UPC #
Product Information
Max Amps
Clip Size
69526
69525
5 Amp
10 Amp
Small
Medium
Annie C-6-1M & HI TL7
Annie C-6-2M & HI TL8
Replaces
69524
15 Amp
Large
Annie C-6-3M & HI TL9
TEST LEAD SETS
Two clips other end with red and black
insulators. 120/240V – AC.
A six-foot lead using number 16-2
wire and female plug one end.
UPC #
Product Information
Max Amps
Clip Size
69528
10 Amp
Medium
Annie C-6-2F & HI TL5
Replaces
69527
15 Amp
Large
Annie C-6-3F & HI TL6
ADAPTER CORD – TEST CONNECTOR
12-inch lead using number 14-3 wire
and female plug one end. Three large
clips other end with
UPC #
69522
red, black and green insulators.
120/240V – AC.
Product Information
Max Amps
Clip Size
15 Amp
Large
Replaces
Annie CA-220- & HI TL11
START SWITCH
A six lead using number 16-2 wire and
male plug one end. Clips with red,
black and white insulators.
UPC #
69523
82
Other end includes push button start
switch. 120/240V – AC.
Product Information
Max Amps
Clip Size
15 Amp
Large
Replaces
Annie C-6-35T & HI TL10
YELLOW JACKET Leak Monitors and
Portable Detectors —
locate problems fast and
save money
IMPROVED
AccuProbe Leak Detector
page 84
UPDATED
Leak Monitoring Information
page 92
83
YELLOW JACKET ACCUPROBE™ LEAK DETECTOR –
heated sensor and Smart Alarm™ to find every leak fast and
1
1
6
99
sure, and know how big
Building on the field-proven original,
this improved unit is the only tool you
need for fast, easy, and certain leak
detection. The heated sensor tip of the
YELLOW JACKET® ACCUPROBE™ Leak
Detector positively identifies the leak source
for all refrigerants even those that other detectors
miss. That includes HCFCs as small as 0.03 oz./yr.;
HFC leaks of 0.06 oz./yr., even R-404A and R-410A; and
CFCs (R-12 and R-502).
1 to 3 =
less than
0.1 oz/yr
4 to 6 =
0.1 to
0.5 oz/yr
7 to 9 =
more than
0.5 oz/yr
Lightweight for handling comfort.
2-year limited warranty
(1-year warranty on sensor).
LED Smart
Alarm™ Indicator
Low battery indicator
(4 AA alkaline)
Sensitivity levels
Audible alarm mute
Sensor not poisoned by large
amount of refrigerant and
does not need recalibration.
Sensitivity adjust
Made in USA
ON/OFF
Flashing
tip
Audible beeping
(can be muted)
Soft-touch grip
AC adapter jack
(adapter included)
18” reach
Frequency of flashes in the tip and
audible beeping increases the closer you
get to the leak source. You zero-in and
the exclusive Smart Alarm™ LED
shows how big or small the leak on a
scale of 1 to 9. Maximum value helps
you determine if the leak needs
immediate repair.
Service life of the replaceable heated
electrochemical sensor is more than
300 hours with minimal cleaning and no
adjustments. Replaceable filters help
keep out moisture and dust that can
trigger false sensing and alarms.
Independent of the Smart Alarm LED,
the unit combines three sensitivity levels
with visual and audible signalling,
including ultra-high to detect leaks
that could be missed with other
detection systems.
84
• Sensor not poisoned by large amounts
of refrigerant
• Position probe for close-up or
extended 18" detection
• Lightweight for handling comfort
• Replaceable filters help keep out
dust and moisture
• Sensor failure mode
• Automatic calibration (no manual
recalibration)
• Leak Standard bottle of non-ozone
depleting chemical included to verify
proper functioning of sensor and
electronic circuitry
• 2-year limited warranty (1-year
warranty on sensor)
Unit is preset at normal sensitivity, but
you can switch to high or low. If there
is no response from the flashing tip or
beeping signal at normal sensitivity in
the general area of a suspected leak,
select high sensitivity. This will detect
even low levels in the general area and
confirm your suspicions. Use low
sensitivity as you move the tip over
more defined areas of a system, and
you will be alerted when the tip
encounters the concentration at the
leak source.
The frequency of flashing from the
heated sensor tip increases as you get
closer to a leak and refrigerant
concentration increases. You can also
turn on the audible alert. Beeping
increases in frequency and duration as
concentration increases.
Technology Comparison –
Heated Sensor or Negative Corona?
Tips for detecting system leaks
1. Inspect entire A/C system for signs
of oil leakage, corrosion cracks, or
other damage. Follow the system in
a continuous path so no potential
leaks are missed.
Heated Sensor Leak Detectors
When the heated sensing element is exposed to
refrigerant, an electrochemical reaction changes
the electrical resistance within the element causing
an alarm. The sensor is refrigerant specific with
superior sensitivity to all HFCs, HCFCs, and CFCs
and minimal chance of false alarms. When exposed
to large amounts of refrigerant which could poison
other systems, the heated sensor clears quickly
and does not need recalibration before reuse.
2. Make sure there is enough
refrigerant in system (about 15% of
system capacity or 50 psi min.) to
generate pressure to detect leaks.
3. Check all service access port fittings.
Check seals in caps.
Negative Corona Leak Detectors
4. Move detector probe at 1" per
second within 1/4" of suspected
leak area.
In the sensor of an old-style corona detector,
high voltage applied to a pointed electrode
creates a corona. When refrigerant breaks the
corona arc, the degree of breakage generates the
level of the alarm. This technology has good
sensitivity to R-12 and R-22, but only fair for
R-134a, and poor for R-410A, R-404A, and
R-407C. Sensitivity decreases with exposure
to dirt, oils and water. And false alarms can
be triggered by dust, dirt specks, soap bubbles,
humidity, smoke, small variations in the electrode
emission, high levels of hydrocarbon vapors, and
other non-refrigerant variables.
5. Refrigerant is heavier than air so
position probe below test point.
6. Minimize air movement in area to
make it easier to pinpoint the leak.
7. Verify an apparent leak by blowing
air into suspected leak to clean the
area and see if the leak remains..
8. When checking for evaporator
leaks, check for gas in condensate
drain tube.
Specifications
Max sensitivity :
0.06 oz. (1.7 g)/yr.
HFC’s R-134a
Max sensitivity :
0.03 oz. (0.9 g)/yr.
HCFC’s R-22
9. Use heated sensor type detector for
difficult-to-detect R-134a, R-410A,
R-407C, and R-404A.
Heated semiconductor
sensor: Over 300 hours life
Maintenance required: No
Affected by humidity: No
Response time: Very fast
Body length: 10 inches (25.4 cm)
Probe length: 18 inches (46 cm)
Warm up time: 25 seconds or less
Battery type continuous life: 4 AA
alkaline, 8 hours
Operating temp. range: 24° to 110°F
(-4° to 43°C)
Storage temp range: -4° to 122°F
(-20° to 50°C)
Description
69365
69366
69367
69368
69378
69380
69381
69382
Heated AccuProbe
Heated AccuProbe European
Heated AccuProbe Japan
Heated AccuProbe Australia/New Zealand
(std w/69368) AC Adapter 230V/50-60 Hz
(std w/69365) AC adapter – 115V/60 Hz
(std w/69366) AC adapter – 230V/50 Hz
(std w/69367) AC adapter – 100V/50-60 Hz
Accessories and Parts
69383
69384
69385
69386
69387
69388
69389
Kit – sensor, filters and bottle
Replacement sensor and filter
Package 5 sensor filters
Leak sensor bottle
Carrying case with inserts
Carrying holster with clip
Battery cover and screw
Alarm
(with mute)
Illuminated
bar graph
LEAK DETECTION
MONITORS
Weight: 20 ounces (0.6 L)
UPC#
YELLOW JACKET COMBUSTIBLE
GAS DETECTOR – with
ultra-sensitive, long life sensor
17" probe for extended reach
Made in USA
Hand-held precision equipment detects
all hydrocarbon and other combustible
gases including propane, methane,
butane, industrial solvents, and more.
See page 91 for details.
Approvals : SAE J1627, CE
85
Fluorescent Leak Detection –
pinpoint leaks at the speed of light.
AC&R Leaks
Leaks usually start small and grow.
When you find a leak early while still
small, it’s easier and faster to repair,
and you save expensive refrigerant.
Whether the system runs continuously
or only part time, dye solution is ready
in the system 24 hours a day to help
you find even the smallest leaks with
a lightweight UV lamp.
Automotive Leaks
69790
Automotive manufacturers are installing
dye in their A/C systems during assembly
to make it easier for service technicians
to pinpoint leak sources. Dye is always
readily visible with a UV beam.
With YELLOW JACKET ® Fluorescent
Leak Scanners, you start by injecting
solution into the system. No need to
steam or clean area before scanning.
Once the solution circulates, leak
sources glow in the beam of the UV
lightgun. It’s that fast and simple.
• Accurate – The source of every leak
glows, even leaks 1/4 oz. per year
• Reliable – See leaks indoors or
outdoors. There are no problems
with halide odors, noxious gases, or
false alarms. Seeing and fixing every
leak saves you the time of no-charge
rework, reduces emissions and helps
meet regulations
• Versatile – Easy-to-use with all
AC&R systems and refrigerant oils
• Long lasting – Works for years
• Energy saving – A system with a
full charge runs more efficiently
With refrigerant loss, a system can
use 25-50% more electricity
• See exact leak location
• Harmless to the system, recovery
units, and the environment
• Find leaks more quickly and from
a greater distance than electronic
detection
Benefits of Fluorescent Scanning
• Lightweight, small and easy to carry
• Find previously undetected leaks
Fluorescent Scanning Applications
Put the technology to work wherever
you find AC or refrigeration systems:
• A/C splits to window units
• Commercial refrigeration from
supermarket to small cabinets
• Property management such as
packaged terminal A/C units
• Centrifugal systems including
marine refrigeration and A/C
• Industrial hydraulic systems
and closed loop water systems
refrigeration
• Chillers
• Transportation refrigeration
• Automotive transmissions,
cooling system, and A/C
YELLOW JACKET MICRO LED UV LEAK DETECTION KITS
Use these high visibility lamps
to spot leaks on all A/C systems.
Individual reflectors surround each
of five LEDs recessed for protection
in the stainless steel head. 69790
features 3 UV and 2 blue bulbs A/C
for detection at greater distances. For
greatest contrast with all fluorescent
dyes, use 69791 with 5 UV bulbs.
86
• 110,000+ hour LEDs
• Constant ON or momentary
ON switch
• Sealing locks out moisture
• Long life lithium battery included
• Aircraft aluminum body
• Limited lifetime warranty
Continued on next page.
Kit
Lamp
only
YELLOW JACKET 3.2 and
2-Watt LED Flashlights
UNIVERSAL PURE UV ™ SYSTEM
Universal is your best choice for all
dye bases including mineral, AB, PAG,
POE, engine, and lubricant.
UPC# Description
69797
Instant on – no warm up.
69773
69796
Compact 3.2-watt unit delivers
85 lumens for up to 250' effective range
and up to 2-hour continuous nondimming illumination (40 lumens for
up to 175' and 5 hours with 2 watt unit).
Patented technology combines
special high quality lens and reflector
to emit only pure UV light (330-380
nanometers). Efficient in close quarters
with power similar to AC lamps. Filter
glasses not required.
69770
69771
69772
69773
69775
69777
69410
69418
69413
Pure UV – flashlight, adapter and case
Pure UV – 90° adapter and case
Pure UV – 90° transformer and case
Pure UV – 90° battery/charger and case
Pure UV – 90° AC/R master kit
w/transformer, A/C dye, coolant dye,
oil dye, adapter hose and case
Pure UV – 90° lamp – 230V with case
Replacement bulb
Filter lens
Filter holding ring
MINI UV BLUE SYSTEM
Features for both include:
• Coolant, oil, and fluid dyes
• Durable carrying case
• Use with battery pack or
AC transformer
• One piece lens that focuses and
projects up to 90% of light in a
uniformly circular beam
• Aircraft aluminum body with
military grade, Type III anodized
finish and sure-grip texture
• Compression sealed for water
resistance
Micro LED High Intensity Lamp
Illuminates
120' away with
5 high intensity
clear bulbs.
Visible at one
mile.
Carrying
pouch
Clear
bulbs
• 110, 000+
hour LEDs
• Individual reflectors surround each
of 5 LEDs recessed for protection
in a stainless steel head
69742
Compact flashlight with patented
Dichrolic filter produces bright UV Blue
light for maximum output in its class.
Kit includes:
• Lamp with 65W bulb and
UV glasses
• A/C dye syringes plus delivery hose
for HVAC/R and auto systems
69740
UPC# Description
69740
69741
69742
69419
69423
Mini
ni lamp, glasses,
clip adapter
gl
Mini lamp above with case
Mini lamp above with A/C, oil and
coolant dyes, delivery hoses and case
UV Blue lens – 2"
Bulb for mini
• Lithium battery for over 20 years
of light and 10-year shelf life
UPC# Description
2 watt LED flashlight
69797
3.2 watt LED flashlight
69787
Micro 5 UV LED kit for ACR
69788
Micro UV LED and dye kit for auto
69789
Micro UV LED and dye kit for ACR
69790
Micro UV LED lamp 3 UV bulbs-2 blue bulbs
69791
Micro Pure UV LED lamp 5 UV bulbs
69792
Micro LED lamp clear bulbs for general use
69793
Replacement pouch for LED
69794
Lithium battery
Accessories
LEAK DETECTION
MONITORS
69796
Common Parts
UPC#
Description
69409
Carrying/storage case
69401
69403
69405
69406
Battery with case and charger
Battery only
Fast/trickle charger only
AC power transformer
69415
Fluorescent viewing glasses for
greatly enhanced visibility
87
YELLOW JACKET®
UNIVERSAL A/C
DYE INJECTORS
AND HOSE
Universal A/C dye injectors work in
AC/R and auto A/C systems. Four 1/4 oz.
applications of dye in each disposable
tube make it economical, fast and clean.
Hose features back flow check valve.
UNIVERSAL A/C DYE SOLUTIONS
UPC# Description
69702
69703
69705
69706
Hose plus 2 injectors for AC/R
Auto R-134a hose, coupling & injectors
Injector hose with SealRight™
Auto R-134a injector hose &
service coupler
CALIBRATED A/C SCREW INJECTION
to A/C low side and rotate handle. AC/R
and auto models.
This 2-ounce injector is easy to refill
and easy to operate. Calibrations are
clearly marked on the injector. Connect
UPC #
Description
69730
69731
Calibrated A/C screw injector
Auto R-134a calibrated A/C screw
injector with service coupler
Auto R-134a calibrated A/C screw
injector without service coupler
69732
DYE AND OIL INJECTORS
• Put oil in after changeout
• Add scanner fluorescent solution
• Add additives to system
• Refrigerant sampling
Body and cap are rugged aluminum
with an O-ring seal. 1/4" male fitting
at one end with Schrader. A ball valve
for control on other end with a short
length of hose. Valve depressor in 1/4"
female end. 600 psi working pressure.
UPC#
Description
69559
1/4 oz. oil injector
69560
1/2 oz. oil injector
69561
2 oz. oil injector
69562
4 oz. oil injector
69563
“O”- ring 1/4 and 1/2 oz. injector (5 pk)
Saves time on many applications:
69564
“O”- ring 2 & 4 oz. injector (5 pk)
• Add oil to system
For auto injectors see page 112.
LARGE
SYSTEM
INJECTORS –
systems
with up to
32 gallons
of lubricant
Self contained injection system for
inducing up to 8 oz. of universal
AC&R dye into the largest systems.
Add to the low side. Easily works on
all system pressures to 300 PSI,
1.5 oz. per stroke. Hose included with
SealRight® end.
UPC #
Description
69555
77950
Large system injector
Large system injector with coupler
DYE APPLICATION AMOUNTS
Application
System size in lbs. of refrigerant
Universal dye amount
Small appliance
A/C or refrigerant systems
Larger systems
up to 4.9 lbs. (2.22 kg)
up to 25 lbs. (11.34 kg)
above 25 lbs. (11.34 kg)
.25 0z. (7.5 ml)
.5 oz (15 ml)
.5 oz (15 ml) per gal. of oil
Compatible with mineral, alkyl, ester and PAG oil systems.
88
Universal dye for A/C systems
with mineral, alkyl, or polyol ester
lubricants.
•
•
•
•
Field proven and sold worldwide
Passed thermal stability tests
One dye for AC/R systems
Raw material QC assures dye
uniformity
UPC# Description
69711
69708
69709
69710
69712
69713
69803
69805
69806
1/4 oz. (7.5 ml) universal A/C – 24/cs.
1/2 oz. (15 ml) universal A/C – 12/cs.
1 oz. (30 ml) universal A/C – 6/cs.
2 oz. (60 ml) universal A/C – 6/cs.
8 oz. (240 ml) universal A/C – 1/cs.
8 oz. (240 ml) universal A/C – 6/cs.
1 gal. (3.78 L) universal A/C – 1/cs.
5 gal. (18.92 L) universal A/C – 1/cs.
55 gal. (208.19 L) universal A/C – 1/cs.
Oil/fluid and coolant dyes available on page 90.
UNIVERSAL A/C DISPOSABLE
INJECTORS
Universal disposable
1 oz. applicator for
fast economical
dispensing. Universal
dye for all common
refrigerants and oils.
Two 1/2 oz. applications for regular split
systems or four 1/4 oz. applications for
small appliances or auto A/C.
oz
.25
ml
7.5
oz
.25
ml
7.5
.25
7.5
oz
ml
oz
.25
ml
7.5
Easy to use: connect to system, push
in plunger, and then disconnect.
• Less costly and faster than many
other methods
• One dye minimizes inventory
• No back-up refrigerant to move dye
into system
• Patented
UPC# Description
69700 1 oz. (30 ml) injector – 6/cs.
(12 residential applications/cs.)
69721 1 oz. (30 ml) injector – 2/pkg.
(4 residential applications/pkg.)
69727 1 oz. (30 ml) injector – 1/pkg.
YELLOW JACKET AC POWERED UV LAMP
for high intensity, contrast, and ease
of detection.
Handle stays cool and vinyl-coated
heat guard cage around the ring helps
keep fingers away from the lens. Cage
also provides a handy stand.
Lightweight pistol-grip lamp with 10
foot cord plugs into any outlet. Metal
housing and lens retention ring with
break resistant lens protects the high
output 160 watt bulb. Lens filters out
virtually all light except pure UV and
concentrates the beam like a spot light
Kit includes light gun with AC cord,
UV spot bulb with ballast, heat guard
cage/stand, high contrast filter, and
UV protective glasses.
UPC #
Description
69435
A/C leak scanner lamp kit
69436
Replacement UV bulb with ballast
69468
Replacement UV filter lens
69438
Heat guard lamp stand
INSPECTION MIRRORS
stainless telescoping
FLUORESCENT LEAK SCANNER SYSTEM II
2. Connect high and low sides. Let high
pressure gas move solution into the
system while throttling refrigerant flow.
3. Add solution to the oil container and
then pump solution into the system.
Complete system includes:
With Scanner System II, you not only
accurately pinpoint every leak at the
speed of light, but also save prep time.
High intensity UV lamp with filter
produces almost pure UV to light up
fluorescent particles in the solution for
the best contrast and fastest, most
visible results. Simply connect the
disposable pre-filled solution injector
tube directly to the AC&R system.
There's no solution mess and you
eliminate the cost and time of a
separate infuser.
1. Use refrigerant from tank to
move solution into low side while
throttling refrigerant flow.
• UL Listed UV lightgun with bulb,
hand grip and heat guard. 110 volt
• Mineral-based pre-filled fluorescent
solution tubes with two bleed valves
• SealRight™ Fitting immediately traps
refrigerant in hose when disconnected
• UV-absorbing anti-fogging goggles
• Service manual and carrying case
UPC #
Description
69631
69632
69460
69461
69464
69466
69467
69468
69474
69498
18993
69470
69670
69671
Leak Scanner System II 120V
Leak Scanner System II 230V
Mist infuser 1/2 oz.
Mist infuser 2 oz.
Complete lightgun with bulb, stand
Replacement UV bulb with ballast
Heat guard/stand for new body
Replacement UV filter lens
UV-absorbing goggles
Carrying case
System control valve
Rubber filter holder for lamp
Bleed valve (1/4" SAE threads)
Bleed valve (1/2" Acme threads)
Mirror
Check leaks in
rotates
hard to see places.
360°
Stainless steel mirror
on ball joint rotates
Extend to 28"
360˚. Handle
telescopes to 28". More mirrors page 111.
UPC #
Description
78100
Round 3 3/4" diameter
78101
Rectangular 3 3/4" x 2"
78102
Rectangular 2" x 1 1/4"
CLEANERS
Scan-off
UV Cleaner
Water-based
biodegradable
spray cleans
scanner solution
from system.
Natural
Degreaser
Heavy-duty biodegradable degreaser
removes scanner solution from system.
LEAK DETECTION
MONITORS
3 simple ways to inject system
UV detection as
preventative maintenance
Leaks generally start small. With
ultra-violet leak scanners for system
surveillance you can keep a small
problem from becoming a bigger,
more expensive one. After installing
the correct dosage of Universal Dye
solution, locate leaks quickly.
The big payback comes on each
subsequent visit. A quick scan of the
system reports to you system status
on all leaks, so you can repair even
the smallest.
Of course UV detection can also be
used to confirm leaks and show the
customer.
Hand Cleaner
Cleans solution from hands.
UPC# Description
Quantity
69698
Natural Degreaser
#01020 19 oz.
Indiv.
69699
Hand cleaner 16 oz.
Indiv.
69696
Spray-off solution 8 oz.
Indiv.
69697
Spray-off solution 8 oz.
12 /case
89
YELLOW JACKET FLUORESCENT SCANNER SOLUTIONS –
technology to match refrigerant and system volume
Different concentrations of Yellow
Jacket fluorescent solutions are
available to match the refrigerant
volume in a system. You also have
the choice of bottles for the original
system or the disposable pre-filled
solution injector tubes for System II.
Injectors
and bottles
Systems up to
2.9 lbs. gas.
01
Systems with
1 to 4.9 lbs. gas.
1
Systems with
5 to 9.9 lbs. gas.
2
Operating temperature:
-40°F for all solutions. Alkylbenzene
in alkylbenzene systems to -100°F.
Systems with
10 to 25 lbs. gas.
3*
4
Large systems use 1/4 oz. per
gallon of oil in system.
* When working on split systems, servicemen generally prefer
to use solution 3 even if system has 10 lbs. of gas or less.
Patented disposable pre-filled
solution tubes.
Self-infusing injector tubes
Ester
Alkylbenzene
oil system
system
Bottles
Solution
concern
System
.size
Mineral
oil system
PAG oil
system
Mineral 0il
system
Ester oil
system
Alkylbenzene
system
01 (.03 oz.)
up to 2.9 lbs.
69610
69620
69600
1 (.5 oz.)
up to 4.9 lbs.
69611
69621
69601
69451
2 (.5 oz.)
up to 9.9 lbs.
69612
69622
69602
69452
3* (.5 oz.)
up to 25 lbs.
69613
69623
69603
4 (2 oz.)
Large**
69454
4 (16 oz.)
Large**
69624
69604
69455
69625
69605
69590
69453
* Use on all split systems.
** Only bottles are available for systems with over 75 lbs. of refrigerant.
For large systems add 1/4 ounce #4 solution per gallon of oil.
Injectors packaged 6/case.
Bottles of solution 12/case.
#4 solution individual bottles.
AC&R bottles
YELLOW JACKET FLUORESCENT SOLUTIONS for non-refrigerant applications
Using your scanner system to help
locate leaks in non-refrigeration and
non-A/C applications adds value and
versatility to your leak scanner system.
The oil and fluid dye solution, and
coolant H 2O dye solution, and H 2O
auto solution all work similarly to the
refrigerant scanner solution above. Pour
in the appropriate amount of dye
solution and use the UV lamp to find
the bright glow.
The oil and fluid
dye solution
is for finding
leaks in oil-based
applications such
as milling machines
and hydraulics,
transmissions,
power steering, and
more. Use one
ounce per 2 gallons of oil.
90
• Pin point leaks in hydraulic
systems such as cherry pickers
circulatory system or static system
that can be pressurized or agitated
• Find seal and gasket leaks in engines,
compressors and transmissions
• Locate leaks in gasoline or diesel
fuel equipment, offset printing
presses, injection-molding machines,
locomotive engine oil coolers, and
oil-cooled chillers
69584 H 2O solution glows blue at
leak sources in large closed-loop water
systems such as boilers and sprinklers.
Use one pint per 1,000 gallons of
water
• Easiest way to detect leaks in storage
tanks and other high volume
containers, as well as associated
piping, valves, condensers, sprinkler
systems, pumps, etc.
• Detect water leakage in any enclosed
Bright blue glow
Coolant dye to
pinpoint leak
sources in
antifreeze-based
automotive water
systems such as
hydronics and
engine radiators.
Use one ounce
per each gallon
of coolant.
UPC# Description
69584
69733
69734
69735
69737
69738
69739
Fluorescent H2O solution, 16 oz. bottle
1 oz. (30 ml) oil and fluid dye – 6/cs.
1 oz. (30 ml) oil and fluid dye – 24/cs.
8 oz. (240 ml) oil and fluid dye – 1/cs.
1 oz. (30 ml) coolant dye – 6/cs.
1 oz. (30 ml) coolant dye – 24/cs.
8 oz. (240 ml) coolant dye – 1/cs.
Frequently Asked Questions
1. Does the UV scanner light work better
than an electronic leak detector?
YELLOW JACKET Combustible Gas Detector –
with ultra-sensitive, long life sensor
No one detection system is better for all
situations. But, with a UV lamp you can
scan a system more quickly and moving
air is never a problem. Solutions also
leave a telltale mark at every leak site.
Multiple leaks are found more quickly.
Illuminated bar graph
2. How is the solution different
from visible colored dyes?
Unlike colored dyes, YELLOW JACKET ®
fluorescent solutions mix completely
with oil and do not settle out.
Lubrication, cooling capacity and unit
life are not affected. And there is no
threat to valves or plugging of filters.
The solutions will also work in a
system containing Dytel.
3. In a system with a mix of mineral
and alkylbenzene oil, which scanner
solution should be used?
Base your choice of solution on whatever
oil is present in the larger quantity. If
you don’t know which oil is in greater
quantity, assume alkylbenzene.
4. How do I test the system?
Put solution into a running system to be
mixed with oil and carried throughout
system. Nitrogen charging for test
purposes will not work since nitrogen
will not carry the oil.
To confirm solution in the system, shine
the lamp into the system's sight glass.
Another way is to connect a hose and a
sight glass between the high and low
sides, and monitor flow with the lamp.
The most common reason for inadequate
fluorescence is insufficient solution in
the system.
5. What’s the most effective way
to perform an acid test?
17" probe for extended reach
Made in USA
Hand-held precision equipment detects
all hydrocarbon and other combustible
gases including propane, methane,
butane, industrial solvents, and more.
Applications
Sensitivity, bar graph, and beeping
to signal how much and how close
• Gas heaters
• Manholes
• Combustion
appliances
• Air quality
Unit is preset at normal sensitivity,
but you can switch to high or low.
After warm-up you’ll hear a slow
beeping. Frequency increases when a
leak is detected until an alarm sounds
when moving into high gas
concentration. The illuminated bar
graph indicates leak size.
If no leak is detected in an area you
suspect, select high sensitivity. This
will detect even low levels in the area
to confirm your suspicions. Use low
sensitivity as you move the tip over
more defined areas, and you will be
alerted when the tip encounters the
concentration at the leak source.
• Ultra-sensitive sensor detects less
than 15 ppm methane and better than
12 ppm for propane. Performs equally
well on a complete list of detectable
gases including acetylene, butane,
and sobutane
• Automatic calibration and zeroing
YELLOW JACKET solutions meet or
exceed applicable ASHRAE and
ANSI tests.
Meets SAE standard J2297 for
R-134a UV leak detection.
• Long life sensor easily replaced after
full service life
• 2-year limited warranty
• And many more features
• Gas lines/pipes
• Propane filling
stations
• Hydrocarbon
refrigerant
• Heat
exchangers
• Marine bilges
• Arson residue
(accelerants)
Specifications
Response time: Instantaneous
Warm up time: 10 seconds
Power:
4 AA alkaline
batteries
Probe length:
17 inches (43.17 cm)
Sensor life:
500 hours
Body length:
10 inches (25.4 cm)
Weight:
20 ounces (.057 kg)
Battery life:
20 hours
continuous
Operating
temp. range:
Approvals:
32° to 110°F
(0° to 43°C)
LEAK DETECTION
MONITORS
Scanner solution affects the color of the
oil slightly. Use a 2-step acid test kit
which factors out the solution in the oil,
giving a reliable result.
Alarm (with mute)
Intrinsic
Safety, CE
UPC#
Description
69373
69301
69371
69387
69388
Combustible gas detector w/case
Sensing Tip
Replacement sensor
Carrying case – blow molded
Carrying holster
69379
Battery cover red and screw
91
Three reasons to monitor
1. Safety and Legal
ASHRAE 15-2001 safety code for
mechanical refrigeration calls for
refrigerant monitoring systems to be
installed in machinery rooms, industrial
occupancy buildings, and refrigerated
rooms such as in factories, plants,
processes, and high probability systems.
Monitors that actuate an alarm and air
ventilation are to be located in all areas
where refrigerant from a leak could
concentrate.
Configure a YELLOW JACKET
Fixed Monitoring System
that’s right for you.
Refrigerant
or ammonia
monitor
In addition, an increasing number of
local regulations govern occupational
health and safety, refrigerant use, and
fixed monitoring as a way to protect
people from hazardous situations:
• Refrigerants are not normally
detected and can displace oxygen
• Most refrigerants do not have an
odor and exposure to flame generates
toxic fumes
2. Economical
With taxes and other factors driving up
the costs of refrigerant, catching and
repairing a leak early makes good
economic sense.
Fast detection and repair also protects
your HVAC&R system, helping control
maintenance and operating costs.
With YELLOW JACKET ™ Fixed Monitoring
Systems for refrigeration leaks, you can
configure controllers and remote sensors
to meet your requirements for point or
perimeter detection. You can monitor
most common refrigerants or ammonia.
Controllers are available using one or
two sensors (shown here) or four or six
sensors (see page 94).
The system first emits an intermittent
siren and constant orange illumination at
the low level, about 100 ppm. At the high
level, usually about 1,000 ppm*, the siren
is continuous and LED is red to signal a
condition that requires immediate action.
To help minimize false alarms, all
systems wait until “certain” of gas in
the air before signalling.
Voltage-free relay switch can activate
ventilation or remote alarms, or report
to control systems. The system features
two relays.
Single sensor system
Includes refrigerant monitor with
refrigerant sensor or ammonia
monitor with ammonia sensor.
Refrigerant
sensor
Ammonia
sensor
controller circuitry is in a coated
steel housing. The maintenance-free
sensors are protected in a high impact
ABS casing. All components are
designed for long-life with mechanical
strength and chemical resistance.
Sensors will not be poisoned by
prolonged exposure to refrigerant.
Easy installation
Systems are factory calibrated.
Controllers and sensors mount to any
flat vertical surface. For point detection,
mount the sensor(s) near the most likely
leak source. With perimeter detection,
sensors surround the potential leak area.
Sensors operate from -20° to 122°F
(-29° to 50°C). From -20° to -40°F
use with environmental enclosure,
page 93.
Typical two sensor, two level installation
To help resist harsh work environments,
3. Environmental
Refrigerants represent possible threat to
the environment. And many refrigerants
are toxic at various concentrations. Early
detection and fast repair is common sense
protection.
92
Applications
•
•
•
•
•
•
Refrigerant storage areas
Supermarkets
Refrigeration machinery rooms
Cold storage facilities
Walk-in coolers
Systems with large refrigerant
volume
• Marine and fishing fleets
• Small deli stores, ice cream
parlors, quick service stores.
Semi-conductor technology
provides a cost/performance balance
that makes YELLOW JACKET systems
an attractive alternative to electrochemical or infrared systems.
* High levels: R-123 is about 300 ppm;
ammonia about 150 ppm.
Two sensor system
Includes refrigerant monitor with
refrigerant sensors or ammonia
monitor with ammonia sensors.
UPC # One and Two Sensor
120V Refrigerant Monitors
UPC #
230V
68004
68104
68008
68091
Refrigerant
or ammonia
monitor
Single sensor monitor
with two level detection
Two sensor monitor
with two level detection
Refrigerant sensor for
two level monitor
68108
68191
UPC # One and Two Sensor
12V
Refrigerant Monitors
68010
68011
Single sensor monitor with
two levels of detection
Two sensor monitor with
two levels of detection
—
—
One and Two Sensor Ammonia Monitors
68032
68036
Refrigerant
sensors
Ammonia
sensors
68093
Single sensor monitor
with two level detection
Two sensor monitor
with two level detection
Ammonia sensor for
two level monitor
68132
68136
68193
UPC # Accessories
Refrigerant sensor is for most common CFCs, HFCs, and HCFCs, plus R-134a,
R-404A, R-410A, R-407C, and R-123. Ammonia sensor is for ammonia only.
68096
68097
68099
500' alarm to sensor cable
1,000' alarm to sensor cable
Monitor key switch set
—
—
—
Specifications
Controller: 7.6" x 4" x 3"; 2.8 lbs.
(193 x 102 x 76 mm; 1.3 kg)
Relays:
Dry contact switch;
10 Amp @ 120/250V max
Sensor:
4.3" x 2.2" x 0.9"
(109 x 56 x 23 mm)
Operates to -20°F (29°C)
Sensors can be hard
wired up to 200' from
controller
ENVIRONMENTAL
ENCLOSURE for sensors
Two versions available:
wall mount affixes to any
surface and duct mount
for sampling air inside
plenum ducts.
UPC #
Description
68089
Environmental enclosure
68084
Duct mount enclosure
Alarm
90 dB @ 18" (456 mm)
Cable:
4-wire alarm with max
3.52 ohms/core/1000'
Power:
120VAC, 60 Hz or
230VAC, 50/60 Hz
Operation: Constant power-on
and fault monitoring
Reset:
Automatic on one level
unit. On two level unit,
automatic on low level;
manual on high level.
MONITOR with 12 volt backup
A single or two sensor, two level monitor
that can be located up to 200 feet from
the controller. UPC # 68010 and 68011.
Integrated Area Monitor
false alarms before signalling. Siren
can be switched off.
Sensor and controller are combined
into a single, compact unit that can be
hard wired into any outlet or power
supply and detects leaks in the area.
The unit emits a continuous siren and
constant red LED illumination at about
1000 ppm. This early warning gives
technicians time to find the leak while
refrigerant concentration is still low.
With adjustable delay, the monitor
waits 0-5, 10 or 15 minutes to avoid
Two voltage-free relays can activate
ventilation or remote alarms, or report
to control systems. Can also be
connected to dedicated 16 unit panel.
Expandable indefinitely by connecting
control panels.
Size: 3.4" x 5.8" x 2.4" (86 x 147 x 61 mm)
Applications: living spaces, marine,
and mechanical rooms.
UPC #
Description
68050
Integrated Area Monitor 115V
68051
Integrated Area Monitor 220/240V
68052
Control panel 115V
68053
Control panel 220/240V
93
LEAK DETECTION
MONITORS
A sensor element
mounted in an area of
high condensation, low
temperature to -40°F,
or direct airflow can
experience a fast
temperature drop causing a false alarm.
These vented enclosures maintain the
proper operating temperature around
the sensor for alarm reliability.
Power LED: Green
YELLOW JACKET 4 AND 6 SENSOR MONITORING SYSTEMS
YELLOW JACKET 4 and 6 sensor monitors
provide all of the benefits of the 1 and 2
sensor systems (pages 92-93), but
increase coverage area and level of
coverage with more sensors at greater
distances from the controller. Cost per
channel are lower. You can locate 4 or 6
sensors up to 500' from the controller.
UPC #
120V
Refrigerant
Monitors
UPC #
230V
68016
Refrigerant four sensor
monitor with two levels
of detection
68116
68024
Refrigerant six sensor
monitor with two levels
of detection
68124
68091
Refrigerant replacement
sensor for two level
refrigerant monitor
68191
Specifications
Controller:
10.3" x 10" x 3.2"
(262 x 254 x 81 mm)
6.3 lbs. (2.9 kg)
Relays:
Dry contact switch;
10 Amp@120/250v max
Power LED: Green
Alarm:
10 dB @ 3 feet (92 cm)
Sensor:
4.3" x 2.2" x 0.9"
(109 x 56 x 23 mm)
0.2 lb. (0.1 kg)
Cable:
4-wire alarm with
maximum 8.8
ohms/core/1000 ft.
Sensors can be hard
wired up to 500' from
controller
Power:
120VAC, 60 Hz or
230 VAC, 60 Hz
Operation:
Constant power-on
and fault monitoring
Reset:
Automatic on one level
unit. On two level unit,
automatic on low level;
manual on high level
Ammonia Monitors
68043
Ammonia four sensor
monitor with two levels
of detection
68143
68047
Ammonia six sensor
monitor with two levels
of detection
68147
68093
Ammonia replacement
sensor for two level
ammonia monitor
68193
See alarm cables on page 93.
RELAY EXPANDER BOX
Enables the 4 or 6 sensor controller to
individualize response to each sensor. For
example, sensor one is set to activate a
fan and auto dialer while other sensors
activate different response systems.
If sensor one detects a leak, only its
corresponding systems are activated.
The other sensors remain in monitoring
mode and will respond individually if a
leak is detected in their specific area.
Ribbon cable connects the relay expander
box to the YELLOW JACKET controller.
Typical Installation
UPC #
120V
Description
UPC #
230V
68028
4 sensor expander box
68128
68029
6 sensor expander box
68129
UPC #
120V
Hydrocarbon
Monitors
UPC #
230V
68064
Hydrocarbon monitor single sensor with
two levels of detection
68164
68068
Hydrocarbon monitor two sensors with two
levels of detection
Hydrocarbon sensor
for two level hydrocarbon monitors only
68168
COMBUSTIBLE REFRIGERANT (HYDROCARBON) GAS MONITORS
The YELLOW JACKET
hydrocarbon sensors
will detect most
hydrocarbons such
as methane,
butane, propane,
and all other products emerging in
refrigerant applications, including:
Propane
Propene
Isobutane
(R-290)
(R-1270)
(R-600a)
Sensors are set at 100 ppm low level, and
1000 ppm for a high level alarm.
94
68094
68194
Guidelines on Locating Sensors
• Do not mount in areas of high heat,
direct solar heat, wetness, dampness,
or where condensation may form on
the sensor
Ceiling
• Do not mount to piping or any
structure subject to vibration
Improper
location in
boiler room
8"-12"
(20-30cm)
• For perimeter detection, place sensors
around the area in question to monitor
the entire space
• For point detection, place a sensor(s)
at a point where you are concerned
about a leak, i.e. at the compressor
24"-36"
(60-90cm)
• For heavier than air gases, place
sensors close to the ground
Floor
• To help prevent false alarms from stray
gas particles such as Volatile Organic
Compounds (VOCs), mount sensors
24" TO 26" from the floor
Sensors must be powered according to
the instruction manual and be within the
cable length from the control unit.
• For lighter than air gases, place
sensors high on the walls or ceiling,
but convenient for maintenance.
Note: Ammonia is lighter than air at
normal temperature but heavier in a
cold room
• Take room shape into consideration
and mount sensors downstream of
any air flow
• In hot rooms, hot air rises to form a
barrier below the ceiling and prevents
gas from getting to a ceiling-mounted
sensor
Mount sensors out of traffic flow areas to
prevent bumping.
Contact Ritchie Engineering for detailed
suggestions.
Remote Systems Control
System on
Sealed area
Installer supplied
power source
Sensor box
Leak Monitor
There are two major types of refrigerant monitoring
systems – Fixed and infrared (IR). Following is a summary
of the differences:
Fixed monitoring System
IR Systems
Measures a broad band of
most common CFCs, HFCs,
and HCFCs, such as: R-11,
R-12, R-13, R-22, R-113, R-123,
R-134a, R-404A, R-407C,
R-410A, R500, R-502 and R-507.
A single sensor
must be used for
each specific
refrigerant.
Less than $500 per sensor
to measure abroad range of
refrigerants.
$1000 and more
per sensor for
each refrigerant.
Installation Controllers mount on any flat
surface and then cable is run
from the controller to the
sensor(s).
Plumbing tube
is used to reach
sensing points.
An additional
tube for exhaust
is also required.
Once you’ve chosen between a Fixed Monitoring System or
an IR System for your application, you’ll have to evaluate
the features that a monitor might include.
• Flexibility is size of controls – Controllers available for 1, 2,
4 or 6 sensors allow you to buy what you need now and plan
to expand in the future
• Two levels of response – A system can emit an intermittent
alarm at a low level, about 100 ppm, indicating that
maintenance is required, and a continuous siren at a high
level, usually about 1000 ppm (R-123 high level is about 300
ppm) indicating that immediate action is required
• Designed to minimize false alarms – Minimize false alarms
by waiting until “certain” that gas is in the air before signaling
• Individualized response by “zone” – Relay expander
panel allows a 4 or 6 sensor system to be “zoned” for fast,
individualized response in a larger application. If one sensor
detects a leak, only its corresponding system is activated. The
other sensors remain in monitoring mode
LEAK DETECTION
MONITORS
Cost
All of these related
products can be triggered
by the monitor alarm. All
are available from your
local fire alarm or building
management suppliers.
Normally open/normally closed dry contact switches
Evaluating Refrigerant Monitors
Gases
Measured
Exhaust fan
Emergency light
Building monitor system
Solenoid valve
Autodialer
Alarm
System off
• Sturdy protective housing – Coated steel housing for
controller circuitry and ABS casing for sensors help protect
the system and keep it maintenance-free
• Protection in harsh environments – An optional vented
environmental sensor enclosure protects a sensor that is
mounted in an area of high condensation, low temperature
to -40°F or direct airflow to avoid a false alarm
95
Frequently Asked Questions
1. Are calibrated leak testers available to
confirm monitor is calibrated correctly?
alarm. Metal oxide technology is
proven for stability and performance
detected at 7500 ppm. As with most
refrigerants, the TWA is 1000 ppm.
Ritchie Engineering does not sell
calibrated leak testers, but gases for
testing leak monitor installations are
available through MSA Mine Safety
Appliances, 121 Gamma Drive,
Pittsburgh, PA 15238-2919.
1-800-672-2222
7. What is the detection sensitivity level
of YELLOW JACKET fixed monitors?
All of the foregoing suggests that for
most CFC, HFC and HCFCs, detection
at 1000 ppm provides a necessary safety
margin for repair personnel. Ammonia
with a significantly lower IDLH of 300
ppm and a TWA of 25 ppm requires
detection at 150 ppm to comply with
50% IDLH requirements. R-123 has a
TWA of 50ppm and an IDLH of 1000
ppm, therefore detection at 100 ppm
provides a good margin of safety.
2. What refrigerants will the leak
monitors detect?
Leak monitors will detect most CFC,
HFC, and HCFC’s. Such as R-11,
R-12, R-13, R-22, R-113, R-123,
R-134a, R-404A, R-407C, R-410A,
R-500, R-502, and R-507. YELLOW
JACKET also has leak monitors
available for ammonia and hydrocarbon
based refrigerants.
The dual sensitivity system has a low
alarm level of about 100 ppm and a
high level of about 1000 ppm for most
CFC, HFC, and HCFC products. The
high level for R-123 is an exception at
about 300 ppm. Ammonia detection
levels are about 100 ppm low and
about 150 ppm high. The alarm level of
all YELLOW JACKET single level systems is
about 100 ppm.
Detection levels are preset at the factory
to cover most situations. If necessary,
however, you can order a custom level,
or adjust the set point on site.
A monitor with a detection threshold of
about 100 ppm for any gas provides an
early warning so that repairs can be
made quickly. This can save refrigerant,
money and the environment.
9. Will the system need recalibration?
8. What concentration must be detected?
3. Can the leak monitor be calibrated
for specific applications?
Yes, the YELLOW JACKET leak
monitor can be calibrated for specific
applications. Contact customer service
for your specific need.
4. If the unit goes into alarm, can it
switch on the fan? Can it turn off the
system at the same time?
The leak monitor has a pair of dry,
normally open/normally closed
contacts that can handle 10 amps at
115 volts. When the sensor indicates a
gas presence higher than the set point,
it opens the closed contacts and closes
the open contacts which will turn
equipment on or off.
5. After a unit goes into alarm and
the contacts close, what can it be
connected to?
The open contacts can shut the system
down, call a phone number, turn on a
fan or emergency light, etc.
6. How does the sensor work?
When the sintered metal oxide surface
within the sensor absorbs gas molecules,
electrical resistance is reduced in the
surface allowing electrons to flow more
easily. The system controller reads this
increase in conductivity and signals an
96
Depends on the refrigerant. For a more
thorough answer, terms established by
U.S. agencies must first be understood:
• IDLH - Immediately Dangerous
to Life and Health
• TWA – Time Weighted Average
concentration value over an 8-hour
work day or a 40-hour work week.
(OSHA or NIOSH levels).
• STEL – Short Term Exposure Level
measured over 15 min. (NIOSH).
• Ceiling Concentration (c) which
should not be exceeded in a working
day (OSHA).
Obviously, the first consideration is
IDLH. For most refrigerants, the IDLH is
relatively high (e.g. R-12 is 15,000
ppm), and such a concentration would
be unusual in a typical refrigerant leak
situation. Leak detection, however, is
still an immediate condition, so the
STEL should be the next consideration,
followed then by the 8-hour TWA or
Ceiling Concentration. R-22, for
example, has a STEL of 1250 ppm and
a TWA of 1000 ppm.(The TWA for
most refrigerants is 1000 ppm).
The draft UL standard for leak monitors
requires gas detection at 50% of the
IDLH. In other words, R-12 with a
IDLH value of 15,000 ppm must be
Factory calibration should be adequate
for 5-8 years. Routine calibration is
unnecessary when used with intended
refrigerants. YELLOW JACKET sensors can
not be poisoned, show negligible drift,
and are stable long term. You should,
however, routinely check performance.
10. Can there be a false alarm?
For monitoring mixtures, the semiconductor must be able to respond to
molecularly similar gases. With such
sensitivity, false alarms can be possible.
Engineered features in YELLOW JACKET
monitors help minimize false alarms:
• The two level system waits about
30 seconds until “certain” that gas
is present before signalling.
• At about 100-1000 ppm calibration
level, false alarms are unlikely.
To prevent an unnecessary alarm, turn
off the unit or disable the siren during
maintenance involving refrigerants or
solvents. Temperature, humidity, or
transient gases may occasionally cause
an alarm. If in doubt, check with us.
YELLOW JACKET System Tools –
everything you need
to do every job right
ED
IMPROV
Tool Cutters page 100
NEW
Service Wrench
page 108
97
Attention to detail – an ongoing process
to assure you of getting full money's worth
with every YELLOW JACKET Tool.
On every service call and every
installation, you can go with just the
right YELLOW JACKET Tool. And go
knowing that every tool passes
a careful quality screening process
that assures you of getting full value
for your money.
This is an ongoing process that
pays close attention to details. After
all, with so many tools available in
the industry, details often make the
difference between the tools of
one manufacturer and another.
On this page, you'll find an overview
of YELLOW JACKET tools in which
details contribute to a unique or
innovative difference.
Even with those more common tools
on the following pages, attention to
detail means you get reliable
performance and the most features
possible for your investment. For
example, the heavy duty pipe wrench
on page 109 includes a special design
for instant grip and release. And the
heavy duty service wrench on page 108
includes a ratcheting mechanism
engineered for heavy use.
When evaluating whether or not a tool
gets the Yellow Jacket name, we
believe no detail is minor.
TIGHT SPOT™ FLARE CUT-OFF
TOOL
Designed specifically
for tight situations where only the flare
must be removed, this cutter makes
clean right angle cuts on 1/4", 5/16" and
3/8" O.D. copper tubing. Interchangeable
arbors for the three sizes included.
Saves time —
1. Where flare nut cannot be moved
back enough for regular cutter or saw.
2. Where it is critical not to
shorten tubing.
UPC #
Description
60122
60196
60197
Flare cut-off tool with arbors
1/4" support arbor
5/16" support arbor
60198
3/8" support arbor
Tips for Cutting Tubing
Premium Forged Service Wrenches –
Enclosed ratcheting mechanism keeps out debris
that could jam the high torquing action. 72 teeth
per end for 5°/6° ratcheting (Page 108).
Swaging and 45° Flaring Tool – Swages 7
sizes: 3/16" through 3/4" O. D. (Page 104).
Cutters are designed for different
applications depending on the
material to be cut. And for optimum
performance the tools must
be used properly.
Tubing cutters are designed for
softer thinner-wall materials such as
copper, aluminum and brass. The
wheel is designed very specifically
with a sharp edge for quick cutting.
If used on black iron pipe, however,
the wheel will quickly be destroyed.
Neither the cutter nor the wheel are
designed for the hardness or wall
thickness of black iron pipe.
Deluxe 45° Flaring Tool – The only full range
1/8" to 3/4" O. D. flaring tool available for soft
copper, brass, and aluminum tubing (Page 102).
98
Ratchet Hand Bender – Versatile, easy-to-use
bender for soft copper, aluminum and light wall
hydraulic tubing (Page 107).
To ensure that lasting tool
performance, use the correct cutters
for copper and the correct pipe cutter
for black iron pipe (see page 100).
YELLOW JACKET PREMIUM TUBE CUTTERS
HEAVY DUTY MINI-CUTTERS
60160
60142
60121
Spare blade stored in handle
Retracted
• Corrosion-resistant finish on
lightweight aluminum frame.
• Small and large sizes available.
• Fold away tool steel reamer with
turned cutting edge.
• Flare cut-off groove for quickly
removing damaged flare.
CONSTRICTOR/CUTTER
Extended
60101
Enclosed precision feed mechanism
for easy, smooth cutting. Resists jams.
Other features include:
Cutter modified with blunt wheel to
roll down the tube O.D.
so it can be mated to a
smaller tube, ie.
capillary tube.
• Wide rollers with flare cut-off
groove for convenience. Ground
surface for easy rolling.
UPC #
Description
60101
60102
Small cutter* for 1/8" to 1-1/8" O.D.
Large cutter* for 1/4" to 1-5/8" O.D.
• Wheel retracts into cutter body to
save 1" in cutting radius.
60103
60014
Constrictor/cutter for 1/4" - 1-1/8" O.D.
6 pk. 60101 Counter display
• Textured finish is easier to grip and
hold with oily hands and gives it a
more professional look.
60015
6 pk. 60102 Counter display
* Conforms to Federal Specification
GGG-C-771-d, 1-31, 64. Type II, Class 1.
Spare parts listed on page 101.
The pioneering 60121 Mini-cutter for
heavy duty cutting from 1/8" to 7/8"
O.D. – not a minor detail when you
consider other
minis with the same
turning radius cut
only up to 5/8".
Wide body for easy
grip. Large rollers
and flare cut-off
groove.
1-3/16"
turning radius
for 60160
Small-Mini 60160–
Smallest version of
the heavy duty model
cuts 1/8" to 5/8" with
a turning radius of
only 1-3/16".
Big-Mini 60142– A larger version with
a heavy duty cast body cuts from 1/4"
to 1-1/8" O.D. and is still compact.
Field proven.
UPC #
Description
60160
Small Mini for 1/8" to 5/8" O.D.
60121
Mini-cutter for 1/8" to 7/8" O.D.
60142
Big Mini for 1/4" to 1-1/8" O.D.
Spare parts listed on page 101.
• Made from high quality alloy steel,
YELLOW JACKET wheels have a
sharper cutting wheel edge for
less burr on copper, aluminum
and mild steel tubing. Does not
"bottom out." Pinned rather than
screwed in position, so it rotates
in either direction
without the screw
backing out.
Counter display pack for increased attention
and sales.
Description
60016
12 pk. 60121 Counter display
60017
12 pk. 60142 Counter display
60018
12 pk. 60160 Counter display
99
SYSTEM
TOOLS
Counter display pack for increased attention
and sales.
UPC #
YELLOW JACKET LARGE TUBE CUTTERS — to 5-1/8" (130mm)
TUBE DEBURRING TOOL
60163
60166
60164
60165
For fast deburring, rotate blade.
60139 (3/8" to 2-5/8")
Improved spring loaded instant
slide action feed is now simpler
and stronger with heat treated
components. The new stronger
"I beam" design uses aluminum
alloy for both strength and light
weight. Wider body has longer
rollers to hold tubing better and
includes a flare cut off groove.
UPC # Description
60146 (2" to 5-1/8")
Push release
opens cutter.
Contoured handle for better gripping
also holds spare cutter wheel. Separate
deburr tool slides into cutter body.
60163
60164
60165
Deburring tool
Replacement blade for 60163
Economy deburr for 60139 tube cutter
60166
Economy deburr for 60146 tube cutter
Push handle and
wheel to tubing.
UPC #
Description
Capacity
60139
Tube cutter
3/8" to 2-5/8"
60146
Large tube cutter
2" to 5-1/8"
60165
Repl. Deburr tool for 60139
60166
Repl. Deburr tool for 60146
TUBE REAMER / BURR
REMOVER
Steel blades
remove inner and
outer burrs.
Spare parts listed on page 101.
PIPE CUTTER for black iron
UPC #
Description
60161
Tube reamer - 1/16" up to 1-3/8"
PVC AND POLYETHYLENE
PIPE CUTTER
MINI-SAW for tight places
Specially designed for cutting small or
large objects in tight areas. Not meant
for hardened steel.
Cuts black iron pipe more cleanly
and quickly than other types of cutters.
For durability, cast iron body holds
heat-treated steel cutter wheel.
• Fine pitch threads assure easy
cuts on black pipe.
• Large rollers for clean right angle cuts.
UPC #
Description
60131
60133
60132
Pipe cutter 6 lbs.
1/8" to 2" pipe
Pipe cutter 14 lbs. 2" to 4" pipe
Pipe cutter wheel for 60131
60134
Pipe cutter wheel for 60133
100
Capacity
Easy ratchet action and unique hooked
tube-gripping jaws give an easy and
clean cut. Other features: heat-treated
steel alloy blade for long life, easily
replaceable, and completely field
repairable.
UPC #
Description
60190
60191
PVC pipe cutter-up through 3/4"
PVC pipe cutter-up through 1-1/4"
60152
PVC pipe cutter-up through 2-1/8"
UPC #
Description
O.A.
Blade
Length Length
60071
60076
Mini saw
Blades
10"
10 pkg.
6"
6"
CAPILLARY
CUTTER
Replacement blades
60193
60194
60155
Spare blade for 60190
Spare blade for 60191
Spare blade for 60152
Replacement blades for old models
60156
60153
60154
Spare blade for 60150 - individual
Spare blades for 60150 - 5pk.
Spare blade for 60151- individual
Cleanly cut capillary tubing without
flattening or constricting tubing.
UPC #
Description
60195
Capillary cutter
UPC#
YELLOW JACKET TUBE CUTTER PARTS – ORGANIZED BY CUTTER
Qty. Pkg.* UPC# Qty. Pkg.* Description
For cutter
60098
60079
60093
60100
60106
60077
60078
60108
60074
60072
60080*
60120*
60144
60124
60136
60169
60172
60173
60174
60165
60147
60141
60166
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
-
60110
1
B
60099
60097
60094
60107
60117
60095
60096
60129
60075
60073
60125*
60116*
60143
60115
60140
60148
60149
-
10
5
5
10
10
5
5
5
5
10
5
20
5
10
5
5
5
-
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
-
Cutter wheels for stainless
Pin and clip for wheel
Clip only for pins above
Pkg. one each wheel, pin, clip
Cutter wheels for copper
Constrictor wheels
Reamer screw and washer
Reamer (improved in ‘84)
Screw for knob
Screw for cutter wheel
Cutter wheels
Screw for cutter wheel
Cutter wheels
Cutter blade pin and clip
Cutter wheels
Screw/retainer
Handle
Screw for handle
Screw & handle
Spring for shaft
Replacement deburr tool
Cutter wheels
Screws for cutter wheels
Replacement deburr tool
60101, 60102, 60103
60101, 60102, 60103
60101, 60102, 60103, 60122
60101, 60102, 60103
60101, 60102, 60103
60101, 60102, 60103
60101, 60102, 60103
60101, 60102, 60103
60101, 60102, 60103
60121
60121
60121, 60123
60121, 60142
60142
60123, 60139
60139
60139
60139
60139
60139
60139
60146
60146
60146
PARTS FOR IMPERIAL™ AND YELLOW JACKET 60122, 60160 CUTTERS
60088
10
B
Cutter wheel 32633
127-FB, 227-FA, TC1050,
60122 and 60160
"
60081
1
B
60085
10
B
Screw 26883
60111
1
B
60089
10
B
Cutter wheel 75015
60112
60082
60113
60083
1
1
1
1
B
B
B
B
60090
60086
60091
60087
10
10
10
10
B
B
B
B
Wheel for stainless 75046
Screw 74762
Cutter wheel 74761
Screw and nut 77511
174-F, 274-F, 312-FB,
374-FC, TC1000,
TC 1020, TC 2050
"
"
206-FA
"
* SP: Skin Pack. B: Bagged
with header.
* For old model with Ritchie imprint.
SERVICE COUNTER KIT 60130
60130
60179
60100
60079
60077
60078
60106
60098
60108
60120*
60072
1
4
3
3
3
3
3
3
6
3
60125*
60074
6
3
60144
60124
60080
60136
60110
3
3
3
3
3
60081
3
For cutter
Counter selection - Tube cutter maintenance kit as below
Kit box only with label - empty
Cutter wheels for copper
Pin & clip for wheel
60101
Reamer screw and spacer
60102
Reamer
60103
Constrictor wheel
Cutter wheel for stainless
Screw for knob
Cutter wheels
60121 (old), 60142
Cutter wheel for new style 60121
60121 (new)
with YELLOW JACKET imprint
Screws for cutter wheel style
60121 (old)
Screw for cutter wheel for new style 60121 (new)
60121 with YELLOW JACKET imprint
Cutter pin and clip for wheel
60142,
Cutter wheels
60123, 60139,
Cutter wheel screw & retainer
60121 (old), 60123
Cutter wheel screw & retainer
60139
Cutter wheel 32633
Imperial TC 1050
127-FB
Cutter wheel screw 26883
227-FA
Imperial is a registered trade mark of Imperial Eastman Acquisition Corp.
* Old style 60121 with Ritchie imprint.
UPC # Qty Description
For cutter
60111
3
Cutter wheel for copper 75015
" TC 1000
Imperial
174-F,
TC1020,
374-FC,
60112
3
Cutter wheel for stainless 75046
60082
3
Cutter wheel screw 26883
274-FC, 174-F
TC 1020, "374-FC
TC 2050,
" 312-FC
60113
3
Cutter wheel 74761
Imperial
Imperial206-FB
206-FB
60083
3
Cutter wheel screw and nut 77511
227-FB "
For restocking kits,
use quantity packs
in chart at top of
this page.
101
SYSTEM
TOOLS
Kit quantities only. Order individual parts from chart above
SERVICE COUNTER CUTTER PARTS KIT 60130
UPC# Qty Description
DELUXE 45°FLARING TOOL –
full range 1/8" to 3/4" O.D.
HEAVY DUTY 45°
FLARING TOOLS 3/16" to 3/4"
UNIVERSAL 45°
FLARE /BURNISH TOOL
Comfort
grip handle
Chrome finish
Flaring and
burnishing cone
This heavy duty tool, designed for
tight places, features:
The only full range 1/8" to 3/4" O.D.
flaring tool available for copper, brass
and aluminum tubing.
• Self-centering yoke for precise
45° flares grips without marring
or constricting tube.
• Automatic tube height gauge for
correct tubing height .
• Multi-faceted burnishing cone to
roll out smooth, polished flare
seat for positive seal.
• Easy-to-use with 4 basic steps.
Match
sizes
• Hardened steel flaring bar to
resist tube slippage.
• Forged steel yoke that slips over
bar and locks with a turn.
• Precision threaded feed screw and
long handle to insure smooth and
easy operation.
UPC # Description
Capacity
60210
Flaring tool
60212
Flaring bar only
60230
60232
Flaring tool
Flaring bar only
3/16, 1/4, 5/16, 3/8
7/16, 1/2, 5/8" O.D.
3/16, 1/4, 5/16, 3/8
7/16, 1/2, 5/8" O.D.
1/2, 5/8, 3/4" O.D.
1/2, 5/8, 3/4" O.D.
60213
60214
60233
Yoke for 60210
Wing nut
Yoke for 60230
Up to 5/8" flare
Universal designed bar will hold all
inch and metric size tubing up to 5/8"
(16mm). Flare bar is more compact
and easier to use in tight quarters.
Multi-faceted cone rolls out precise
45˚ flare and polishes it at the same
time. Flare is formed above flare bar.
UPC #
Description
Capacity
60275
Universal
flaring tool
Flaring bar only
Flaring yoke only
3/16" to
5/8" O.D.
for above
for above
60276
60277
Up to 3/4" flare
LARGE SIZE 45°
FLARING TOOLS 3/4" to 1-1/8"
FLARE / BURNISH TOOL
Opened
1. With cone up,
open the two dies of
the clamping yoke.
2. Select sizes on
underside of dies to
match tubing O.D.
Yoke slips over
flaring bar.
Yoke locks on
with a turn.
Height
gauge
45° burnished flare
3. Insert tubing until
it touches the height
gauge.
4. Turn the feed
screw to flare the
tubing.
UPC #
Description
Capacity
60280
Deluxe flaring tool
1/8" - 3/4"
60281
45° flare cone only
60282
Yoke assembly only
Additional parts in price sheet.
102
Tool designed to flare on the larger size
tubing – up to 1-1/8". Flaring bars are
hardened and grip tubing securely. Yoke
slips over flaring bar and locks in place.
Long handle and precision threaded
feed screw ensure easy flaring.
UPC #
Description
Capacity
60290
Large flaring tool
3/4, 7/8, 1,
1-1/8" O.D.
for above
for above
Up to 3/4"
60293
60292
Flaring yoke
Flaring bar
Multi-faceted cone rolls a precise flare
and simultaneously polishes it on brass,
copper and aluminum.
UPC # Description
Capacity
60270
60271
60272
3/16" to 5/8" O.D.
for above
for above
Flare/burnish tool
Flare yoke only
Flaring bar
YELLOW JACKET ECCENTRIC CONE FLARING TOOL
60295
Off-center
hardened steel
cone produces a
rolling action
for uniform
flare walls
without galling in
3/16" to 3/4"O.D. tubing.
Large feed screw handle turns with
little effort for smooth operation.
• Black oxide-finished steel flaring
bars are heat-treated for durability
and secure grip on tubing
• Recommended for soft materials
such as copper and aluminum
• Recommended by some mini-split
manufacturers for R-410A flare
UPC #
Description
60295
Flaring tool with eccentric cone
for 3/16" to 3/4" O. D.
YELLOW JACKET PREMIUM DOUBLE AND SINGLE FLARE 45° TOOL
60201
Single flare tool
Fixed
yoke
( 37° tool also
available on request.)
Swing away
yoke
60202
Double flare tool
(Must order 60203
double flare bar
separately.)
One-piece tool single flares six sizes of
copper, brass, aluminum and most
mild steel tubing. Forms flare above
clamping block without thinning flare.
Deeper grooves in bar for improved
gripping power.
• Hardened steel block; and steel
handles and body for durability
• Automatic flare cone centering
for consistent flare precision
60202 also features a swing away yoke
so tool can also double flare 3/16" to
1/2" tubing when used with 60203
YELLOW JACKET FLARING/CUTTING KITS
UPC # Description
60230
60250
60260
60260
60225
60211
Order 60203 bar separately
UPC #
Description
Capacity
60201
3/16, 1/4, 5/16, 3/8
1/2, 5/8" O.D.
3/16, 1/4, 5/16,
3/8, 1/2, 5/8" O.D.
3/16 to 1/2" O.D.
60205
Single flare
tool only - 45°
Double flare
tool only - 45°
Double flare
bar for 60202
order separately
Flaring cone - 37°
60209
60216
60206
Flaring tool - 37°
Flaring cone - 45°
Roller and pin
60202
60203
__
__
__
__
Tips for Flaring
A wide variety of heavy duty tool kits
for flaring 1/8" to 3/4" O. D.
60240
double flare bar (order separately)
Full range 45° flaring kit for
1/8" to 3/4" O.D. with yoke, two bars,
case, instructions
45° flaring tool only for 1/2"-3/4" O.D.
45° flaring/cutting kit for 3/16" to 5/8"
O.D. with 60210 flaring tool, 60101
cutter, case, instructions
Full range 45° flaring/cutting kit for
1/8" to 3/4" O.D. same as 60240 with
60101 cutter, case, instructions
45° double flaring kit with with five
adapters for 3/16" to 1/2" O.D., case,
instructions
45° double flare five-adapter set for
3/16"-1/2" O.D.
An incorrect flare is one of the
most common sources of leaks. To
help prevent leaks and call backs,
cut tubing with sharp wheel in a
quality cutter (page 99) for a clean
right-angle cut. To avoid tube
constriction, use a light hand on
the feed screw.
Since unremoved burrs can break off
into the tubing or scratch the flared
surface, remove burrs with a
deburring tool (page 100).
60225
103
SYSTEM
TOOLS
A flare tool with burnishing cone
puts a high polish on the flare and
rolls out a perfect 45° flare for a
good seal. Over or under flaring
prevents a good seal. Use drop of oil
on the flaring cone and feed screw
for precise action.
YELLOW JACKET SWAGING AND 45° FLARING TOOL 3/16" to 3/4"
attaching adapters to the feed screw,
adapters are deeply knurled. Flaring
bars are hardened and chrome plated
for durability.
Kit comes complete with six swage
adapters, flaring cone, two flaring bars,
yoke, and a deluxe case.
This combination tool both flares
and swages soft or annealed copper
and similar materials. Six hardened
and plated alloy steel adapters are
interchangeable to easily convert sizes
and functions. Slip-on self-centering
steel yoke has a feed screw with extra
long handle. For a sure grip when
UPC #
Description
60440
60450
60444
60439
60445
60446
60447
60448
60449
60442
60441
60443
60212
Swage/flare kit complete
3/16" to 3/4" O.D.
Swage/flare kit, case only
3/16" and 3/8" adapter
1/4" adapter
5/16" adapter
1/2" swage adapter
5/8" swage adapter
3/4" swage adapter
Flare cone 3/8" to 3/4"
"C" clip and nut
Handle/feed screw/nut
Complete yoke 60440/60453
Flare bar 3/16" to 5/8" O.D.
60232
Flare bar 1/2" to 3/4" O.D.
Parallel Expansion Joint
Swages 7 sizes: 3/16" through 3/4" O.D.
Reduction Joint
SWAGE/45° FLARING TOOL 1/2" to 3/4"
PUNCH-TYPE SWAGING TOOL
Durable
heat-treated
and plated
alloy steel tool
expands one
end of copper
tubing for
connecting
same size
tubes.
Mid-size swaging and flaring tool for
1/2", 5/8" and 3/4" O.D. tubing.
UPC #
Description
60453
Swage/flare kit - complete
1/2" to 3/4" O.D.
60446
60447
60448
60449
60441
1/2" swage adapter
5/8" swage adapter
3/4" swage adapter
Flare cone 1/2" to 3/4"
Handle screw assembly
60442
"C" clip and nut
60443
Complete yoke for 60453/60440
UPC #
Swaging Sets
60232
Flare bar 1/2" to 3/4" O.D.
60475
Set – 4 pcs. in pouch –
1/4, 3/8, 1/2 and 5/8"
60476
Set – 5 pcs. in pouch –
1/4, 5/16, 3/8, 1/2 and 5/8"
60461
Set with clamping bar and
6 swaging punches 3/16 to 5/8"
60462
Clamping bar only
UPC #
Single Tools
60460
60463
Multi swage punch
6 sizes 3/16 " to 5/8"
3/16" O.D. punch
60464
60465
1/4" O.D. punch
5/16" O.D. punch
60466
60467
60468
60469
3/8" O.D. punch
1/2" O.D. punch
5/8" O.D. punch
3/4" O.D. punch
60470
7/8" O.D. punch
LARGE SIZE SWAGE/45° FLARING TOOL 3/4" to 1-1/8" O.D.
Swages 3/4", 7/8" and 1-1/8" O.D.
tubing. Flares 3/4", 7/8", and 1-1/8"
O.D. tubing.
104
UPC #
Description
60455
Large swage/flare kit complete
3/4" to 1-1/8" O.D.
60448
60457
60458
60459
60441
3/4" swage adapter
7/8" swage adapter
1-1/8" swage adapter
Flare cone 3/4" to 1-1/8"
Handle screw assembly
60442
"C" clip and nut
60456
Complete yoke 60455
60292
Flare bar 3/4" to 1-1/8" O.D.
60475
60460
YELLOW JACKET TUBING EXPANDER/SWAGER 5/16" to 1-5/8" O.D.
Kit 60407
The savings of precise swages
instead of couplings
• 100% of couplings
• 50% of solder points
With long handles for comfortable
leverage, you can easily expand 5/16"
to 1-5/8" O.D. soft copper and
aluminum tubing in seconds. Handles,
tapered expanding pin, and other
moving surfaces are heat treated for
long-term durability. Select from nine
expander heads to attach to the front
of the handles.
Wide range of capabilities:
• Precise swaging on the job
• Re-round deformed tube and fitting
ends
• Help salvage shorts and scrap to
make couplings
• Use on .063" wall soft copper and
aluminum to 1-5/8" O.D. (anneal
hard copper prior to use)
• Use on .047" wall soft steel to
1-1/8" O.D.
• Use on .039" wall stainless steel to
7/8" O.D.
• 50% of time
• possible leaks
Sets in case
UPC #
Description
60407
Expander kit with handles; heads for 3/8", 1/2", 5/8", 3/4", 7/8", 1-1/8" tubing O.D.;
deburring tool, steel carrying case, instructions
Expander handles
Steel carrying case
60412
60426
Expander heads
UPC #
Description
Max. Wall
Thickness
A
B
60413
60414
60415
5/16" expander head
3/8" expander head
1/2" expander head
0.039"
0.039"
0.047"
0.24"
0.35"
.043"
__
0.06"
0.06"
60416
60417
5/8" expander head
3/4" expander head
0.047"
0.047"
0.57"
0.59"
0.06"
0.06"
60418
60420
60422
7/8" expander head
1-1/8" expander head
1-3/8" expander head
0.047"
0.063"
0.063"
0.71"
0.77"
0.77"
0.06"
0.09"
0.09"
60424
1-5/8" expander head
0.063"
0.77"
0.09"
3-IN-1 SWAGING AND FLARING TOOL
for hard and soft copper
This revolutionary tool swages soft
and hard copper, and flares soft
copper. Swaging hard copper lowers
the cost of joining, eliminating the
time and expense of annealing.
UPC #
Description
60480
Basic set – Swage 1/4", 3/8", 1/2"
and 5/8" O.D. Flare 3/16" to 5/8" O.D.
60482
Complete set – 3/16" to 5/8" O.D.
60481
Tool only – less adapters
60483
Swage adapter – 3/16"
60484
Swage adapter – 1/4"
60485
Swage adapter – 5/16"
60486
Swage adapter – 3/8"
• Quick-change swaging adapters
heat-treated to take continual use.
60487
Swage adapter – 1/2"
60488
Swage adapter – 5/8"
• Automatic self-centering of
swaging adapters and flaring
cone for consistent results.
60489
Flaring cone
60490
Case only
60491
Detent pin
60492
Detent spring
• One-piece construction with
hardened steel clamping dies.
1. Swage HARD copper
2. Swage soft copper
3. Flare soft copper
• 50% of soldering material
105
SYSTEM
TOOLS
• Set includes heavy duty carrying
case and 60161 tube reamer.
FIN STRAIGHTENERS
61150 Fin Tool
straightens
condenser and
evaporator fins
quickly and
easily – even
severely
damaged ones.
61150
61170
Also cleans
away lint,
rust, dirt and
other debris.
Adjustable tension and sturdy
metal body.
61170 is similar to 61150 with a
longer comfort-grip handle making
straightener easier to use. Head
is 20% wider to straighten more
fins in one pass.
ERGONOMIC FinFix™ COMBS for 14 different fin sizes
Color coded nylon fin combs are
designed to easily straighten and clean
fins on standard and high efficiency
condensers and evaporators. Available
individually bagged, or as a set of
6 assorted. One set of 6 covers
12 different fin sizes. Also bulk bag
of 25 of the same size. Newest comb,
61157, is for high efficiency units.
Improved shape conforms to the hand
and thumb for more comfortable grip.
Individual
Individual
U.P.C. No.
61151
61152
Bag of 25
Bag of 25
U.P.C. No.
Description
Fins
per inch
Color
FinFix 1
8 and 10
Orange
61161
FinFix 2
9 and 15
Yellow
61162
61153
FinFix 3
11 and 13
Blue
61163
61154
FinFix 4
12 and 14
Green
61164
61155
FinFix 5
16 and 17
Lime
61165
61156
FinFix 6
18 and 20
Red
61166
61157
FinFix 7
21/22 and 23/24
Purple
61167
61158
Set of 6
8 to 20
Assorted
—
6-in-1 Fin Straightener
Clean:
insert forward.
UPC #
61150
61170
Fin straightener sizes are marked on
head - 8, 9, 10, 12, 14, and 15 fins per
inch. Compact 4" length.
Straighten:
insert backward
Description
UPC #
Description
Fin straightener
61171
6 -in-1 fin straightener
Fin straightener with large handle
61172
Head only
61173
Handle only
SAFETY GOGGLES
YELLOW JACKET RETAINING RING PLIERS –
COMBINATION INTERNAL/EXTERNAL
Six point
broached jaw
for accurate tip
alignment.
Adjustable for
hex tips.
High handle-to-jaw ratio
for increased mechanical
advantage.
Compact pliers for use on SealRight™
coupler with interchangeable tips. Works
on internal and external retaining rings
in a variety of areas:
• Where bearings are used.
• Where a shaft must be held in a bore.
• Under the dashboard and more.
Helps protect your eyes against metal
particles, sparks, refrigerant gases, etc.
when working on HVAC&R systems.
Safety goggles are recommended any
time you work on a system.
UPC #
Description
11002
Safety goggles
11003
Ventilated safety goggles
106
Patented
push-button
convertability
for internal
and external
use.
Adjustable stop
for efficient internal
ring installation and
prevention external
ring damage.
Includes pouch with
five pairs of alloy steel
replaceable tips
and hex
wrench.
Spring
return for
easy control.
UPC# Description
60593
Small pliers for 1/4" - 1” (8 mm - 26 mm)
internal rings; 1/8" - 1” (3 mm - 26 mm)
external rings.
60594
Medium pliers for 3/8" - 2”
(10 mm - 48 mm) internal rings; 1/4" - 2”
(7 mm - 48 mm) external rings
60596
Replacement tip set for 60593: straight
.023" (0.6 mm), .036" (0.9 mm), 047" (1.2 mm);
90° .036" (0.9 mm), .047" (1.2 mm)
60597
Replacement tip set for 60594: straight
.036" (0.9 mm), .047" (1.2 mm), .070" (1.2 mm);
90° .036" (0.9 mm), .047" (1.2 mm)
YELLOW JACKET RATCHET HAND BENDER
The original one hand bending tool for
soft copper, aluminum and light wall
hydraulic tubing from 3/8" to 7/8".
• New stronger bending bar
• Bending shoes change quickly.
Trouble free ratchet mechanism.
Bend 3/4" tube to 90˚ in less than
10 seconds.
Bending
3/4" copper.
• Index marks ensure bending to length.
Complete swing bender kit includes all
items shown to bend 3/8", 1/2", 5/8",
3/4" and 7/8" tubing per case.
CAUTION: do not use with hard copper.
Optional reverse bend kit —
Attaches to bender and bends
tubing from the
outside of bend.
60342
UPC# Description
Bending
Radius
60331
60332
60333
60334
60335
60336
60337
60338
60342
60339
–
1-3/16"
1-3/8"
1-15/16"
2-13/16"
3-3/8"
–
–
–
–
Complete kit
3/8" mandrel
1/2" mandrel
5/8" mandrel
3/4" mandrel
7/8" mandrel
Crossbar assembly
Steel case with inserts
Reverse bend adapter
Ratchet body
Replacement parts for 60331
60328
60343
60344
60345
60346
60347
60348
60349
60340
Fillister head screw
Bending body housing (10)*
Catch pin (13)*
Catch lever (16)*
Flat spring (17)*
Feed lever (19)*
Wing nut and E-clip (1-1/8)*
Tension spring
Ratchet bar (9)*
–
–
–
–
–
–
–
–
–
* Designates the call-out number from the
parts diagram on the 60331 instruction sheet.
FULL RANGE HEAVY DUTY
TUBE BENDERS for 1/4"
to 7/8" radius
The balance of the line features special hardened wearing surfaces to help
maintain accuracy. Conforms to Fed.
Spec. GGG- B-191-a Type III,
Class 2.
5/8" to 7/8"
1/4" to 1/2"
60390
Make fast bends on almost
every size of soft copper, brass,
aluminum, steel and soft
stainless steel tubing to 180°.
60390 is a compact three-in-one
bender for 1/4", 5/16" and 3/8" O.D.
tubing. Calibrated markings for bends
up to 180° help you duplicate angles.
UPC #
Description
Bending
Radius
60390
15/16"
60373
60374
1/4"-5/16"-3/8"
3-in-1 tube bender
1/4" tube bender
5/16" tube bender
9/16"
11/16"
60375
60377
60378
3/8" tube bender
1/2" tube bender
5/8" tube bender
15/16"
1-1/2"
2-1/4"
60379
60380
60395
60396
60397
60398
3/4" tube bender
7/8" tube bender
Bolt for bender hook
Hook/bolt 60378
Hook/bolt 60379
Hook/bolt 60380
3"
3"
NA
NA
NA
NA
PRECISION TUBE BENDER for hard and soft copper
Mount in a vise
Make precision bends in hard and soft
copper, and soft steel in commercial
applications. Patented bending shoe gives
two bending points for accuracy even on
hard copper. Bends to 180˚ for vise
mounting. Includes one handle.
Tube O.D.
Bending
Radius
60321
60323
5/8"
7/8"
2.50"
3.25"
Wall Thickness
Min.
Max.
(Ref. #)
0.040"
0.040"
(2.5216)
(2.5222)
0.080"
0.080"
Specially designed YELLOW JACKET
spring benders slip over soft copper
and aluminum tubing during bending
to help prevent tube collapse.
• Silver-plated finish.
• Conforms to Fed. Spec.
GGG-B-191-a Type IV.
UPC #
Single Bending Springs
60354
60355
60356
60357
1/4" O.D. bending spring
5/16" O.D. bending spring
3/8" O.D. bending spring
7/16" O.D. bending spring
60358
60359
60360
60361
60351
1/2" O.D. bending spring
5/8" O.D. bending spring
3/4" O.D. bending spring
7/8" O.D. bending spring
Set–6 sizes–1/4", 5/16",
3/8", 7/16", 1/2" and 5/8" O.D.
Set–4 sizes–1/4", 3/8",
1/2" and 5/8" O.D.
Set–4 sizes–1/2", 5/8",
3/4" and 7/8" O.D.
60352
60353
107
SYSTEM
TOOLS
UPC #
SPRING TUBE BENDER
for 1/4" to 7/8"
SERVICE WRENCHES STRAIGHT
YELLOW JACKET PREMIUM FORGED SERVICE WRENCHES
• No reversing mechanism to wear
out; simply turn wrench over for
reversing.
60613
Standard reversible ratchet wrench with
square openings: 1/4" and 3/16" at one
end; 3/8" and 5/16" at other end.
• Uses less work room for ratcheting.
• Heat-treated chrome vanadium
forging for durability.
Patent pending
HEAVY DUTY
60618
• Enclosed ratcheting mechanism to
keep out debris that could jam the
action.
• Higher torque ratings than 60613.
Heavy duty version of original 60613
with heavier handle and larger gear.
Stronger gear teeth are combined with
strong reversing mechanism for long
service life.
SERVICE WRENCH AND ADAPTER
Square opening 3/16" and 1/4" at one
end; 3/8” and 5/16" at other end.
60610
• 72 teeth per end for 5°/6° ratcheting.
UPC#
Description
60600
60601
60629
Forged wrench 1/4" and 3/8" sq.
Forged wrench 3/16" and 5/16" sq.
Set of 60600 and 60601 above
60619
60620
Display pak 60600 (25 pcs.)
Display pak 60601 (25 pcs.)
60638
OFFSET
60609
60616
KNUCKLE SAVER design for convenience in tight areas. Square opening
1/4" and 3/16" one end; 3/8" and 5/16"
at other.
For large service valves
60615
Combination service wrench with 60609
hex adapter for accessing liquid and
suction based valves on residential and
commercial units up to 7.5 tons. Heattreated hex works for 3/16" and 5/16"
hex valves. Black oxide plated. New
adapter for some York/Coleman units.
SPORLAN VALVE WRENCH
Reversible wrench for larger service
valves. 3/8" square one end; 1/2"
square at other.
7" LONG RATCHET WRENCH
for service valves
60612
Heavy duty reversible ratchet wrench
with hex openings 1/2" and 9/16" at
one end; and square 3/16" and 1/4" at
other end.
Service wrenches
UPC#
Description
60609
60610
Hex key adapter
60613 service wrench and
60609 adapter
Shorter 3/16" and 5/16" hex key adapter
to fit some York/Coleman units
60638
Spanner end tightens packing nut
around super heat adjustment stem.
1/8" square end adjusts Sporlan solenoid valves with manual lift stems as
on Series B6 and E6 through MA 50.
Also 3/16" square at same end for
expansion valves.
UPC#
Description
60617
Sporlan valve wrench
PINCH-OFF TOOLS
60661 pinches off copper and other
lines quickly. Trigger release.
60661
60666
UPC#
Description
60613
Straight service wrench
60618
Heavy duty service wrench
60616
Off-set service wrench
60615
Refrigeration wrench for large valves
60665
Bar-style pinch-off and reround tool
60612
Heavy duty wrench – 7" long
60661
60666
Plier type pinch-off tool
ViseGripM RR pinch-off tool
CAUTION: Do not use cheater bars.
108
60666 is the ViseGrip® pinch-off tool.
60665
60665 will pinch off and reround 1/4,
5/16, 3/8 and 1/2" copper.
UPC#
Description
YELLOW JACKET RATCHETING BIT WRENCHES
REFRIGERANT RECOVERY PLIERS
• Reverse direction with a flip of the
reversing pawl.
60584
These bit wrenches allow access
where conventional screwdrivers and
bit drivers fail to reach.
• 25° offset angle keeps your knuckles
up and away from the work surface.
• Knurled spinner wheel for finger
tightening of fasteners.
UPC #
Description
60584
60585
Set includes bit #1 and #2 Phillips,
1/4", and 9/32" slotted.
Ratcheting driver wrench only
60586
60587
60588
#1 Phillips bit (5pk)
#2 Phillips bit (5pk)
Small slotted bit (5pk)
60589
Medium slotted bit (5pk)
E-Z GRIP RATCHETS with comfort grip handles
operation even when used frequently.
Heat-treated gear hex for long life.
Easy-to-hold handles and reversing
mechanism provide comfortable
UPC #
Description
Hex Sizes
60664
60655
Set 6 wrenches
Ratchet wrench
1/4" to 9/16"
1/4"
60656
60657
60658
Ratchet wrench
Ratchet wrench
Ratchet wrench
5/16"
3/8"
7/16"
60659
60660
Ratchet wrench
Ratchet wrench
1/2"
9/16"
UPC #
Description
60667
60668
19022
Refrigerant recovery pliers
Replacement needle and gasket
Replacement gasket only (5 pkg)
HEAVY DUTY PIPE WRENCH
Designed for strength and durability
with malleable iron construction, this
heavy duty wrench features:
• Replaceable heat treated jaws.
KNUCKLE-SAVER ™ HEX WRENCH SETS - 3 pc. or 5 pc.
• Accurately sized and broached
ends for correct fit.
• Heat-treated critical wear parts
for long life.
• Finger control reversing.
• Chrome plated for durability.
The unique offset design of these
YELLOW JACKET® wrenches save your
knuckles in tight places.
The fastest and easiest way to evacuate
refrigerant before disposal of a unit.
Snaps onto refrigerant line and punctures
super large hole for immediate and
maximum full flow to recovery unit.
One adjustable tool fits all sizes from
3/16" to 7/8" O. D. hard tubing.
Replaceable hardened steel needle.
UPC #
Description
Hex Sizes
60630
60631
Set - 5 wrenches
Set - 3 wrenches
1/4" to 7/8"
1/4" to 9/16"
60633
60634
60635
Ratchet wrench
Ratchet wrench
Ratchet wrench
1/4" x 5/16"
3/8" x 7/16"
1/2" x 9/16"
60636
60637
Ratchet wrench
Ratchet wrench
5/8" x 11/16"
3/4" x 7/8"
• Instant grip and release jaws.
UPC#
Description
60641
60642
8" Pipe wrench
10" Pipe wrench
Capacity weight
1"
1-1/2"
.9 lbs.
1.7 lbs.
60644
60645
60646
14" Pipe wrench
18" Pipe wrench
24" Pipe wrench
2"
2-1/2"
3"
3.3 lbs.
5.2 lbs.
8.2 lbs.
STRAP WRENCH
UTILITY CHAIN WRENCH
Lightweight tool with double heat-treated
forged steel handle and tempered steel
chain. Reach tight places near walls and
areas most wrenches cannot be used.
Easy-to-use strap attaches easily for
quick gripping of chrome or nickel
finished pipe without gouging the
finish. Sturdy one-piece construction.
UPC #
Capacity
Weight
UPC #
Capacity
Weight
60654
4" dia.
1.9 lbs.
60651
17 "
0.7 lbs.
SYSTEM
TOOLS
109
YELLOW JACKET FAN BLADE PULLER
12" HEX KEY WRENCHES
This all purpose tool is designed tough
to last.
• Heat treated for long life.
• Chamfered ends for easy insertion
into
sockets.
All steel design includes a 15/16" hex
head and 5/8" shaft milled back 1-1/2"
and undersized for 1/2" shaft opening.
A self centering alignment tool is
included.
• Black
finish.
Four fingers attach to the fan blade. For
durability they are made of hardened
4140 chrome moly steel.
• All purpose tool.
• Remove squirrel cage type blower
wheels.
• Pull off fan blades.
• Remove pulleys or sheaves.
• Fits 1-3/4" hub max.
UPC #
Set 7 pcs. Hex Key wrenches,
includes all sizes below
Fan blade puller complete
60591
Replacement "fingers" (4)
60757
60758
5/64
3/32
12"
12"
1-3/4"
1-3/4"
60857
60858
60592
Bolt for 60590
60760
60762
1/8
5/32
12"
12"
1-3/4"
1-3/4"
60860
60862
60763
60764
60765
3/16
7/32
1/4
12"
12"
12"
1-3/4"
1-3/4"
1-3/4"
60863
60864
60865
FOLD-UP HEX KEY SETS
Standard end
Ball end
• Corrosion-resistant finish.
110
UPC #
Individual
60590
• Chamfered square cut
ends for easy socket
insertion.
Provides fast full
socket engagement where
regular hex keys cannot
do the job.
B
60750
All YELLOW JACKET hex keys
from .050" to 5/16" are
premium 8650 heat-treated
steel alloy for rugged use.
Other features:
Ball end keys ease
tightening of fasteners
where sockets are up
to 30° off axis.
A
Description
UPC #
YELLOW JACKET HEX KEYS
• Patented organizer case with
identifying slots that lock
keys in place when not in use.
Size
25 per pkg.
UPC #
Description
UPC #
Std. End
Ball End
Size
Length
60670
12 pc. set w/case
60685
60669
Metric – 12 pc. set w/case
—
All individual keys below are in 10 pkg.
60671
60672
60673
.050
1/16
5/64
2.8 inches
3.0 inches
3.2 inches
60686
60687
60688
60674
60675
60676
60677
60678
3/32
7/64
1/8
9/64
5/32
3.4 inches
3.6 inches
3.7 inches
3.9 inches
4.1 inches
60689
60690
60691
60692
60693
60679
60680
60681
60682
60683
3/16
7/32
1/4
5/16
–
4.5 inches
4.9 inches
5.1 inches
6.0 inches
Case
60694
60695
60696
60697
60698
Locate the
correct key
size easily. For rugged use, each key is
premium 8650 heat-treated steel alloy.
Other features:
• Chamfered square cut ends for
easy socket insertion.
• Corrosion-resistant finish.
• Smooth one-piece handle with
sizes clearly marked.
• Keys snap to work position for
leverage and fold into handle for
compact storage.
• Replacement keys available.
UPC #
Description
60700
Hex key set – 8 sizes - .050, 1/16
5/64, 3/32, 7/64, 1/8, 9/64, 5/32"
60710
Hex key set–9 sizes - 5/64, 3/32,
7/64, 1/8, 9/64, 5/32, 3/16, 7/32, 1/4"
HAND-HELD REFRACTOMETER
GLASS MIRRORS —
telescoping
INSPECTION MIRRORS —
stainless telescoping
All mirrors
have
telescoping
feature. Some
have clips for
pockets and
magnifying
glass.
Replaceable
mirrors.
Place sample liquid
on prism and close
cover.
Mirror
rotates 360°
Extend to 28"
Look through the
eyepiece and focus
for scale reading.
UPC #
Description
Extension
For retrofitting a mineral oil system
with Solest® HFC, this field tool can
accurately predict remaining mineral
oil in the system down to 1%.
Acceptable levels of remaining oil
depend on compressor/system
manufacturer requirements.
78094
2-1/4" round
9-1/4" to 14-1/4"
78097
2-1/4" round
magnified
9-1/4" to 14-1/4"
Refractive range 1.435 to 1.520 at
room temperature.
78104
With pocket clip and insulated head
78098
78099
78103
1-1/4" round
1-1/4" round
magnified
2" x 3-1/2"
rectangular
1" x 2" oval
7" to 19"
7" to 19"
Check leaks in hard to see places.
Stainless steel mirror on ball joint
rotates 360˚. Handle telescopes
to 28".
UPC #
Description
78100
Round 3-3/4" diameter
78101
Rectangular 3-3/4" x 2"
78102
Rectangular 2" x 1-1/4"
11" to 15-1/2"
7" to 19"
Replacement mirrors only
78105
2-1/4" round glass
UPC #
Description
78106
2” x 3-1/2” rectangular glass
69000
Hand-held refractometer w/case
78107
1" x 2" oval glass
SAFETY GOGGLES
VALVE CORE TOOL
Self contained tool for quickly
removing and replacing cores. Handle
contains six cores.
UPC #
Description
19306
Valve core tool
Helps protect your eyes against metal
particles, sparks, refrigerant gases,
etc. when working on HVAC&R
systems.
Safety goggles are recommended any
time you work on a system.
AUTOMOTIVE R-134a and R-12 CAN TAPS
UPC#
With side tap, handles slip around and
close to pierce the can. Small inserts
for use with lubricant cans.
Check valve on side taps help prevent
back pressure into can.
Not for use with other refrigerants.
UPC #
Description
36192
36193
36194
R-134a side can tap
R-12 side can tap
Gaskets for side can tap (10 pak)
Description
11002
Safety goggles
11003
Ventilated safety goggles
SYSTEM
TOOLS
111
MAX-FLOW ™ COMBINATION OIL PUMP
REFILLABLE OIL INJECTORS
• Remove oil for
recovery and
conversion.
• Universal stopper automatically
adjusts to all standard openings in
1, 2 1/2 and 5 gallon oil containers.
• Add oil to existing
systems.
• Suction transfer hose and fittings
included. Connects to bottom of
unit to pump oil from equipment
quickly and efficiently.
With the Max-Flow pump,
you can smoothly pump oil
into the compressor
on the down stroke while the
system is under pressure.
This makes pumping easier
with a positive
stroke.
Pumps 2.6 ounces
or 78 ml per
stroke.
Other features:
• Pumps against 200 psi pressure.
• Use with alkyl-benzene, esterbased, polyol ester, mineral, and
synthetic oils.
UPC#
Description
77940
Improved Max-Flow
combination oil pump with tubing
Automatic stopper for oil container
openings for new 77940 pump
“O”- ring kit for 77940
Automatic stopper for oil container
openings for original 77900 pump
77941
77942
77919
77920
Adapter fitting straight –
1/8" NPT Male x 1/4" flare
77921
Adapter fitting 90° angle –
1/8" NPT Male x 1/4" flare
24" suction hose –
1/4" fitting one end only
77922
• Comfort-grip rubber handle.
Note: Not for use ammonia laden oil.
MAX-FLOW ™ DELUXE OIL PUMP
• Remove oil
for recovery
and conversion.
• Add oil to
existing systems.
• Fits all size oil
containers
• Operating unit in reverse with
adapter hose accessory removes
oil from equipment quickly and
efficiently.
• Use with alkyl-benzene, esterbased, polyol ester, mineral,
and synthetic oils.
OIL PUMPS
• Will pump against 250 psi pressure.
UPC#
Optional accessories
Improved for added reliability and a
more powerful stroke, the Max-Flow
deluxe oil pump is a high capacity
unit for quick charging. Pumps 3.8
ounces (112.38 ml) per stroke.
Other features:
• Foot stand base provides support
and leverage while pumping against
the high pressures of a running
compressor.
112
Description
77930
77924
77925
77931
Max-Flow Deluxe oil pump
3/8" NPT Male x 1/4" Fe. elbow
Plastic seat
"O" ring kit for 77930 (10 pak)
77932
77935
77936
Piston rod assembly
Ball spring – 2 each
Replacement suction copper tube
with 1/2" flare nut at one end
77933
Replacement fittings —
3/8" NPT Male x 1/2" fl. — 90°
77937
Replacement fittings —
3/8" NPT Male x 3/8" fl. — 90°
77938
Optional 1/2" flexible suction hose,
24" long — fitting one end only
Optional 3/8" flexible drain hose,
24" long — fitting one end only
1/2" copper gasket soft (10 pak)
77939
59653
Body and cap are rugged aluminum
with an “O”-ring seal. Male fitting at
one end with Schrader. A ball valve
for control on other end with a short
length of hose. Valve depressor in
female end.
Saves time on many applications:
• Add oil to system.
• Put oil in after changeout.
• Add scanner fluorescent solution.
• Add additives to system.
• Refrigerant sampling.
• 600 psi maximum working pressure.
UPC#
69560
69561
Description
1/2 oz. oil injector
1/4" Male flare x 1/4" Female Q.C.
2 oz. oil injector
1/4" Male flare x 1/4" Female Q.C.
69562
4 oz. oil injector
1/4" Male flare x 1/4" Female Q.C.
69563
69564
69565
“O”- ring 1/2 oz. injector (5 pk)
“O”- ring 2 & 4 oz. injector (5 pk)
1/2 oz. R-134a auto injector
w/hose and service coupler
2 oz. R-134a auto injector
w/hose and service coupler
69566
69567
4 oz. R-134a auto injector
w/hose and service coupler
PRODUCT NUMBER INDEX
UPC #
Page #
00101 – 32
00438
UPC #
Page #
18995 – 34
UPC #
Page #
UPC #
Page #
19130 – 19, 37
19132
21012 – 26, 49
21024
19133 – 19, 20,
37
21024
18997 – 34, 76
11002 – 38, 106,
11003 111
19000 – 34
11012 – 25
14072
19003 – 37
19005
14536 – 28
14699
15006 – 22, 72
15036
19010 – 25, 37
16801 – 30
16912
18001 – 28, 36,
37
19143 – 36
19152
21036 – 26, 49
29999 – 29
21036 – 49
31012 – 32
32624
21048 – 26, 49
21399
32633 – 101
21403 – 27
21586
32636
32836
19015 – 19, 20,
29, 34,
37
19161 – 36, 38
19162
21981 – 49
21982
36192 – 38, 111
36194
26, 28,
29, 37
19030 – 19, 20
19034 – 37
21983 – 26, 49
21988
19165 – 36, 38
19169
19171 – 36
19203
19208 – 35
19209
19210 – 36
19214
21983
22012 – 27
22988
18985, 18981
40190 – 51, 58
40199
41045 – 46
41047
40201 – 64
40206
41048 – 49
41049
40261 – 51
40263
41051 – 50
41055
40265 – 38
41056 – 49, 50
41142 – 46, 49,
50
40270 – 46
40271
41057 – 50
41060
41143 – 49
41150
41212 – 47
41220
41132 – 37
40279 – 46, 49,
50
41063 – 46, 50
19304 – 36
19095 – 26, 34
19306 – 35, 111
26202 – 26
19096 – 20, 34
19310 – 29
19350
26236 – 28
26399
19448 – 30
19512
26883 – 101
19100 – 35
19128 – 35
19129
41044 – 46, 49
25980 – 26
25988
19094 – 35, 37
19118 – 36
19125
38079 – 11
39870
19236 – 29
19296
26036 – 29
26199
19117 – 35
41131 – 49
41061 – 49, 50
26002 – 26
18993 – 34, 89
41130 – 46
40272 – 20
19302 – 25, 26,
27, 36
19111 – 36
19116
41041 – 46, 49
41042
25836 – 29
25950
19038 – 35
19090
18981 – 34
18989
41125 – 9
19220 – 36
19222
18412 – 30
18550
19110 – 22, 29,
36, 51,
72
41123 – 37, 58
41124
40944 – 57
25001 – 26
25802
25999 – 29
18978 – 34, 76
18980
40802
19217 – 35
19301 – 36
19109 – 35
32
41133 – 46, 49
41135
41138 – 37
19037 – 27, 35,
37
19101 – 36
19106
41123
41043 – 49
18072 – 28
18372
18973 – 34
18974
18975 – 20, 34,
76
58
19158 – 36, 38
19027 – 35, 37
18971 – 20, 34
41122
36018 – 19, 37
36019
18172
18961 – 38
18962
40801 – 42, 53
40805
21612 – 26, 49
21799
19026
Page #
29983 – 27
29996
19160 – 19, 37
19022 – 37, 109
UPC #
41119 – 35, 51,
19012 – 30, 37
19021 – 37
Page #
40350 – 35
19153 – 38
19157
19020 – 25, 26,
27, 28,
29, 34,
35, 37
UPC #
29980 – 26
19011 – 19, 26,
28, 29,
34, 35,
37
19025 – 37
18612 – 28
18912
Page #
19142 – 36, 38
19163 – 35, 38
15012 – 29
16696
49
UPC #
40280 – 49
40281
40311 – 38
40314
41067 – 42, 53
41069
41139 – 20, 46
41141 – 49
41222 – 57
41225
41232 – 47, 48
41090 – 46, 49
41096
41233 – 48
41235
41099 – 49
41101 – 50
41102
40318
41103 – 46, 49,
50
41104 – 50
41282 – 57
41295
41300 – 38
41305
41311 – 47
41315
27002 – 26
19636 – 29
19999
41105 – 49
27101 – 28
28599
40315 – 35
40317
20036 – 28
20199
29001 – 26, 35
40318 – 35, 51
20236 – 29
20399
29003 – 27
29199
40319 – 51
40320
20436 – 28
20599
20636 – 29
20750
20812 – 30
20950
29201 – 26, 35
40321 – 38
40324
29203 – 27
29799
40325 – 35
29836 – 29
29975
40331 – 51
40342
41106 – 46, 49,
50
41107 – 50
41109
41111 – 51
41112 –
41113 – 46
41116 – 46, 50
41117
41118 – 51
41317 – 38
41318
41319 – 47
41332 – 57
41340 – 51, 58
41346
41353 – 57
41365
41372 – 47
41382 – 57
41652
113
PRODUCT NUMBER INDEX
UPC #
Page #
UPC #
Page #
UPC #
Page #
UPC #
Page #
UPC #
Page #
41703 – 47
41711
44285 – 57
44295
49137 – 61
49138
49301 – 63
49420
49960 – 44
49968
41712 – 47, 57
44311 – 47
44319
49143 – 65
49146
49421 – 63, 81
49969 – 55
49970
41715 – 47
41780 – 57
41781
41842 – 48
49422 – 63
44355 – 57
44365
49424 – 63, 81
45213 – 47
45319
49425 – 63
49458
49973 – 44
49997
UPC #
Page #
60147 – 101
60149
60152 – 100
60156
60160 – 99, 101
59511 – 80
42001 – 48
42007
49495 – 64
46000 – 43
46094
46120 – 54
46190
59652 – 32, 37
49151
49151 – 61
49152
49000 – 50, 62
49001 – 62
49002 – 20, 62
49153 – 65
49170
49171 – 66
49176
49801 – 45
49802
49803 – 56
49806-– 56
49816
42010 – 47
42219
49008 – 62
49833 – 56
49010 – 49, 50,
61, 62,
64, 65
49835 – 45
42233 – 48
42235
42332 – 48
42436
49025 – 65
49034
42715 – 47
43220
49035 – 62, 65
49036
43225 – 57
43233 – 48
43235
43285 – 57
43295
49039 – 61
49049
49051 – 62
49052
49053 – 65
49064
49067 – 61
49069
49071 – 62
49084
43315
49090 – 45, 50,
49092 54, 62,
65
43311 – 47
43319
49095 – 62, 66
49096
43355 – 57
43365
49100 – 50, 61,
65
44213 – 47
44220
49101 – 61
49106
44225 – 57
44233 – 48
44235
114
60072 – 101
60075
60076 – 100
49177
49013 – 62
49016
60014 – 99
60018
60071 – 100
49831 – 45
49832
42313 – 47
42315
59654 – 37
59655
49805 – 45
49003 – 65
49006
42020
59653 – 37, 112
49836 – 56
49856
49177 – 62, 66
49178
49860 – 45
49868
49179 – 62
49180
49869 – 56
49870
49190 – 45, 46,
49192 54, 62,
65
49883 – 45
49889
49197 – 61
49206
49903 – 55
60407 – 105
60426
60163 – 100
60164
60439 – 104
60476
60165 – 100, 101
60166
60480 – 105
60492
60169 – 101
60174
60584 – 109
60589
60177 – 37
60178
60590 – 110
60592
60179 – 101
60593 – 106
60597
60101 – 99, 101
60103
60106 – 101
60120
49235 – 61, 65
49236
60121 – 99, 101
49237 – 61
49238
49905
49251 – 61
49252
49905 – 44
49906 – 55
49916
60212 – 102, 104
60638 – 108
60213 – 102
60214
60641 – 109
60664
60216 – 103
60225
60665 – 108
60666
60230 – 102, 103
60667 – 109
60668
60232 – 102, 104
60233 – 102
60270 – 102
60292
60131 – 100
60134
60292 – 104
60136 – 101
49935 – 44
60139 – 100, 101
49281 – 45
49282
49936 – 55
49131 – 65
49132
60140 – 101
60141
49283 – 44
49952 – 44
49955
49135 – 61, 65
49136
49291 – 43
49292
49956 – 55
60600 – 108
60629
60630 – 109
60637
60123 – 101
60130
49933 – 55
60600
60211 – 103
60240 – 103
60260
60135 – 37
49271 – 48
49272
60196 – 98
60198
60122 – 98, 101
49922 – 44
49932
49253 – 65
49270
60190 – 100
60195
60210 – 102
60101
60331
60161 – 100, 105
60201 – 103
60209
49902 – 44
49231 – 65
49232
49243 – 65
49246
60077 – 101
60100
Page #
60146 – 100, 101
59651 – 37
42000 – 47
UPC #
60293 – 102
60669 – 110
60865
61151
61150 – 106
61173
68004 – 93
68011
68016 – 94
68029
60295
60142 – 99, 101
60295 – 103
68032 – 93
68036
60143 – 101
60144
60321 – 107
60398
68043 – 94
68047
PRODUCT NUMBER INDEX
UPC #
Page #
UPC #
Page #
68050 – 93
68053
69000 – 111
69008 – 79
68064 – 94
68068
69010 – 80
69015
68084 – 93
68089
69044 – 20, 64
69045
UPC #
Page #
UPC #
Page #
69733 – 90
69739
78112 – 30
78306 – 30
78510
69365 – 69, 85
69368
69060 – 22, 72
69371 – 79, 91
69373
78512 – 30, 32
69790
69740 – 87
69797
69378 – 69, 85
69379 – 79, 91
69803 – 88
69806
69380 – 69, 85
69386
74761 – 101
77511
69387 – 69, 79,
85, 91
77919 – 112
77920
69388 – 69, 79,
85, 91
77921 – 20, 112
68116 – 94
68129
69389 – 69, 85
77922 – 112
77942
68132 – 93
68136
69401 – 87
69423
77950 – 88
68093
68091 – 93, 94
68093
Page #
78113 – 32
78260
69365
69063 – 72
UPC #
78618 – 32
78772
80200 – 19
80240
81636 – 31
86836
UPC #
Page #
93592 – 18
93597
93797 – 19
93812
93822 – 11
93825 – 34
93831
93832 – 26, 34
93833
93834 – 34
93840
93842 – 26, 34
93843
93011 – 19, 64
68094 – 94
68096 – 93
68108
69075
69064 – 22, 72
69075
93012 – 19
93058
93844 – 34
93848
93850 – 20
93886
95002 – 9
95014
95100 – 9, 10
78011 – 81
68143 – 94
68168
69435 – 89
69438
78012 – 30, 81
68191 – 93, 94
68193
69451 – 90
69455
78020 – 81
78032
69460 – 89
69498
78041 – 30
78044
69522 – 82
69532
78050 – 80
78055
69555 – 88
69559
78056 – 63, 80
78057
93211 – 20
69560 – 88, 112
69564
78059 – 80
78060
93340 – 19
93344
69565 – 112
69567
78061 – 63, 80
93350 – 18
93352
68194 – 94
68800 – 71
68801
69080
69079 – 21, 73
69087
69088 – 73
69090
69091 – 21, 73
69092 – 19
68803
68802 – 70, 71
68803
69093 – 19, 22
69103 – 76
69110
68804 – 71
68818
69200 – 75
69224
68848 – 37
68849
69225 – 74
69228
68850 – 77
68855
69233 – 75
69584 – 90
69625
78062 – 80
78065
68900 – 78
68916
69671 – 89
69699
69239 – 76
78066 – 80
78075
93089 – 18
93095
95753 – 8
95756
93098 – 19
93117
95760 – 7, 10
95762 – 7
95767
93365 – 19
93378
95700
93386 – 18
93387
95770 – 8, 10
93390 – 19
93509
95772 – 8
95777
78097 – 81, 111
78099
93560
68945
69346 – 77
69348
78076 – 81
78091
95740 – 6, 10
78095 – 81
78096
69250 – 76
69265
69301 – 79, 91
93092
78094 – 81, 111
69240 – 74
68945 – 71
68949
95700 – 8, 10
78066 – 63
69631 – 89
69632
69670 – 34, 89
69235 – 74
69237
95121 – 9
95457
69711
69700 – 88
69732
78100 – 81, 89,
78102 111
78103 – 81, 111
78107
93540 – 18
93590
93591 – 19
115
WARRANTY STATEMENT:
Many factors beyond the control of Ritchie
Engineering Company, Inc. can affect the
use and performance of the products in this
catalog. It is essential that the user evaluate
any product in this catalog to determine the
suitability of that product for a specific
application. Using any product in a way that
is not accepted as common practice can result
in injury. All products are for use as described
only. See full warranty on our dealer and
wholesale price sheets.
MANUFACTURERS REPRESENTATIVES – USA
Kivlan Group
P.O. Box 740
Carlisle, PA 17013
Phone: 717/249-6019
Fax:
717/960-1528
E-mail: [email protected]
Web site: www.kivlangroup.com
Morley Associates Inc
146 Cedar Street
Branford, CT 06405
Phone: 203/488-8944
Fax:
203/488-9790
E-mail: [email protected]
Web site: www.morleyassociates.com
Hardage & Pollex, L.L.C.
8200 Blankenship
Houston, Tx. 77055
Phone: 713/464-5544
FAX:
713/461-9915
e-mail: [email protected]
Web site: www.HardagePollex.com
Monti and Associates, Inc.
P.O. Box 866
Arlington Heights, IL 60006
Phone: 847/956-8200
Fax:
847/956-8237
E-mail: [email protected]
Web site: www.ma-line.com
E.V. Dunbar Company
125 Townpark Drive
Suite 150
Kennesaw, GA 30144
Phone: 770/218-1750
Fax:
770/218-1756
E-mail: [email protected]
Web site: www.evdunbarco.com
RCI II
2188 West 190th Street
Torrance, CA 90504
Phone: 310/533-1365
Fax:
310/533-5145
E-mail: [email protected]
CANADA
MEXICO, CENTRAL and
SOUTH AMERICA
EUROPE
B.J. Williams & Associates, Inc.
745 Development Drive, Unit 4-B
Kingston, ON K7M 4W6
CANADA
Phone: 613/389-2879
Fax:
613/389-4967
E-mail: [email protected]
Web site: www.actoolsource.com
C.L. Overseas, Inc.
7801 N.W. 72nd Avenue
Medley, FL 33166
Phone: 305/863-0305
Fax:
305/863-9055
E-mail: [email protected]
Web site: www.cloverseas.com
Fairfield Technologies
Fairfield House
St. Martins
Guildtown Perthshire PH2 6AE
UNITED KINGDOM
Phone: 00-44-(0) 1738-550-005
FAX:
00-44-(0) 1738-550-015
e-mail: [email protected]
10950 Hampshire Avenue So.
Bloomington, MN 55438-2623 U.S.A.
Phone: 952/943-1333 or
800/769-8370
FAX: 952/943-1605 or
800/322-8684
See the YELLOW JACKET ® Products wholesaler in your area.
© 2006 Ritchie Engineering Company, Inc.
08/06 CP
Printed in U.S.A.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF