Sinclair Large Series ASF-09AL, ASF-12AL, ASF-18AL Floor Ceiling Air Conditioner SERVICE MANUAL
Below you will find brief information for Large Series ASF-09AL, Large Series ASF-12AL, Large Series ASF-18AL. These floor ceiling air conditioners are designed to provide efficient and reliable cooling and heating. They feature advanced control systems, including a microcomputer control system and 3-speed motor for accurate temperature adjustments. The units also come equipped with a compression-moulded water tray and pressure-viscosity insulating material to prevent condensation water formation. The Sinclair Large Series ASF-09AL, ASF-12AL and ASF-18AL are a great choice for various commercial and residential applications.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
SERVICE MANUAL FLOOR & CEILING LARGE SERIES ASF-09AL, ASF-12AL, ASF-18AL Floor Ceiling Series 1 . Introduction and Features Main Function and Features: New style Compact design Low noise Prolonged filter Micro computer control Complete unit of low height,sawing construction space High cooling (heating) capacity, low noise, 3-speed motor for adjustment to meet different requirements High-quality materaial and strict process control to ensure quality of the unit and prolong the use life Compression-moulded water tray,pressure-viscosity insulating material to avoid condensation water Models ASF-09AL ASF-12AL ASF-18AL 2 Specifications and Technical Parameters ASF-09AL Model COOLING Function Rated Voltage HEATING 220-240V~ Rated Frequency 50Hz Total Capacity (W/Btu/h) 2500(W) 2800(W) Power Input (W) 890 980 Rated Input (W) 1200 1140 Rated Current (A) 5.54 3 5.25 550(H) Air Flow Volume (m /h) (H/M/L) Dehumidifying Volume (l/h) 1.6 EER / C.O.P (W/W) 2.8 Energy Class / ASF-06AL Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (W) 790/670/550 10 Input of Heater (W) / Fan Motor Capacitor (uF) 1 0.2 Fan Motor RLA(A) Centrifugal Fan- 2 Fan Type-Piece φ125 × 134 Aluminum fin-copper tube Diameter-Length (mm) Evaporator φ7 2/1.6 Pipe Diameter (mm) Row-Fin Gap(mm) Indoor Coil length (l) × height (H)× unit coil width (L) Swing Motor Model 586×25.4×247.6 MP35CA Output of Swing Motor (W) 2 Fuse (A) Sound Pressure Level dB (A) (H/M/L) Sound Power Level dB(A) (H/M/L) Dimension (W/H/D) (mm) Dimension of Package (L/W/H) (mm) Net Weight /Gross Weight (kg) PCB 3.15A 45/42/39 55/52/49 836/238/695 935/805/295 27/35.5 3 Floor Ceiling Series Model of Outdoor Unit ASF-09AL Compressor Manufacturer/trademark Shenyang Compressor Model ASG108CV-B7AT Compressor Type rotary compressor 18 L.R.A. (A) 4.28 Compressor RLA(A) 922 Compressor Power Input(W) KA-172-LYGN914 Overload Protector Throttling Method Capillary Starting Method Capacitor Working Temp Range (℃) -50 Aluminum fin-copper tube Condenser ф7 2-1.4 Pipe Diameter (mm) Rows-Fin Gap(mm) 714×25.4×495 Coil length (l)×height (H)×coil width (L) Fan Motor Speed (rpm) 850 Output of Fan Motor (W) 30 Outdoor Fan Motor RLA(A) unit Fan Motor Capacitor (uF) 0.484 2 / Air Flow Volume of Outdoor Unit Fan Type-Piece Axial fan –1 Fan Diameter (mm) ф400 Auto defrost Defrosting Method T1 Climate Type I Isolation IP24 Moisture Protection Permissible Excessive Operating Pressure for the Discharge Side(MPa) Permissible Excessive Operating Pressure for the Suction Side(MPa) 3.8 1.2 Sound Pressure Level dB(A) (H/M/L) 54 Sound Power Level dB(A) (H/M/L) 64 Dimension (W/H/D) (mm) 848/320/540 Dimension of Package (L/W/H)(mm) 878/360/590 30/34 Net Weight /Gross Weight (kg) R410A/0.95 Refrigerant Charge (kg) 5 Length (m) 30 Gas additional charge(g/m) ConneLiquid Pipe (mm) Outer ction Diameter Gas Pipe (mm) Pipe Height (m) Max Distance Length (m) 6 12 5 10 In case of any change of data,please refer to the nameplate. 4 ASF-12AL Model Function COOLING HEATING Rated Voltage 230V~ Rated Frequency 50Hz Total Capacity (W/Btu/h) 3500(W) 3900(W) Power Input (W) 1230 1290 Rated Input (W) 1570 1800 Rated Current (A) 8.05 7.5 3 600(H) Air Flow Volume (m /h) (H/M/L) Dehumidifying Volume (l/h) 1.6 EER / C.O.P (W/W) 2.8 Energy Class ASF-12AL Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (W) 790/670/550 10 Input of Heater (W) - Fan Motor Capacitor (uF) 1.5 Fan Motor RLA(A) 0.15 Fan Type-Piece Centrifugal Fan- 2 φ125×134 Aluminum fin-copper tube Diameter-Length (mm) Evaporator φ7 3/1.6 Pipe Diameter (mm) Row-Fin Gap(mm) Indoor Coil length (l)×height (H) × unit coil width (L) Swing Motor Model 586×38.1×247.6 MP35CA 2 Output of Swing Motor (W) PCB 3.15A Fuse (A) Sound Pressure Level dB(A) (H/M/L) Sound Power Level dB(A) (H/M/L) Dimension (W/H/D) (mm) Dimension of Package (L/W/H) (mm) Net Weight /Gross Weight (kg) 46/42/38 56/52/48 836/238/695 935/805/295 27/35.5 5 Floor Ceiling Series ASF-12AL Model of Outdoor Unit Compressor Manufacturer/trademark Shenyang Compressor Model C-RV146H1C Compressor Type rotary compressor L.R.A. (A) 30 Compressor RLA(A) 5.7 Compressor Power Input(W) 1245 Overload Protector B235-150-241E Throttling Method Capillary Starting Method Capacitor Working Temp Range (℃) -50 Condenser Aluminum fin-copper tube ф7 2-1.4 Pipe Diameter (mm) Rows-Fin Gap(mm) Coil length (l)×height (H)×coil width (L) 714×25.4×495 Fan Motor Speed (rpm) 850 Output of Fan Motor (W) 30 Outdoor Fan Motor RLA(A) unit Fan Motor Capacitor (uF) 0.15 2.5 Air Flow Volume of Outdoor Unit ---- Fan Type-Piece Axial fan –1 Fan Diameter (mm) ф400 Auto defrost Defrosting Method Climate Type T1 Isolation I Moisture Protection IP24 Permissible Excessive Operating Pressure for the Discharge Side(MPa) 3.8 Permissible Excessive Operating Pressure for the Suction Side(MPa) 1.2 Sound Pressure Level dB(A) (H/M/L) 56 Sound Power Level dB(A) (H/M/L) 66 Dimension (W/H/D) (mm) 848/320/540 Dimension of Package (L/W/H)(mm) 878/360/590 Net Weight /Gross Weight (kg) 40/44 Refrigerant Charge (kg) R410A/1.25 Length (m) 5 Gas additional charge(g/m) ConneLiquid Pipe (mm) Outer ction Diameter Gas Pipe (mm) Pipe Height (m) Max Distance Length (m) 30 6 12 5 10 In case of any change of data,please refer to the nameplate. 6 ASF-18AL Model COOLING Function HEATING Rated Voltage 230V~ Rated Frequency 50Hz Total Capacity (W/Btu/h) 5000(W) 5600(W) Power Input (W) 1790 2090 Rated Input (W) 2210 2220 Rated Current (A) 11.5 11.5 3 700(H) Air Flow Volume (m /h) (H/M/L) Dehumidifying Volume (l/h) 1.6 EER / C.O.P (W/W) 2.8 - ASF-18AL Energy Class Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (W) 1070/970/870 40 Input of Heater (W) - Fan Motor Capacitor (uF) Fan Motor RLA(A) 3 0.2 Fan Type-Piece Centrifugal Fan- 2 φ125 × 134 Aluminum fin-copper tube Diameter-Length (mm) Evaporator φ7 3/1.6 Pipe Diameter (mm) Row-Fin Gap(mm) Indoor Coil length (l)×height (H)× unit coil width (L) Swing Motor Model 586×38.1×266.6 MP35CA 2 Output of Swing Motor (W) PCB 3.15A Fuse (A) Sound Pressure Level dB(A) (H/M/L) Sound Power Level dB(A) (H/M/L) Dimension (W/H/D) (mm) Dimension of Package (L/W/H) (mm) Net Weight /Gross Weight (kg) 54/50/46 64/60/56 836/238/695 935/805/295 27/35.5 7 Floor Ceiling Series ASF-18AL Model of Outdoor Unit Hitachi Compressor Manufacturer/trademark Compressor Model ASH218SV-C8LU Compressor Type rotary compressor 40 L.R.A. (A) 8.25 Compressor RLA(A) 1785 Compressor Power Input(W) built in Overload Protector Throttling Method Capillary Starting Method Capacitor Working Temp Range (℃) -50 Aluminum fin-copper tube Condenser ф7 2-1.4 Pipe Diameter (mm) Rows-Fin Gap(mm) 753×25.4×655 Coil length (l)×height (H)×coil width (L) Fan Motor Speed (rpm) 780 Output of Fan Motor (W) 60 Outdoor Fan Motor RLA(A) unit Fan Motor Capacitor (uF) 0.2 3 ---- Air Flow Volume of Outdoor Unit Fan Type-Piece Axial fan –1 Fan Diameter (mm) ф460 Auto defrost Defrosting Method T1 Climate Type I Isolation IP24 Moisture Protection Permissible Excessive Operating Pressure for the Discharge Side(MPa) 3.8 Permissible Excessive Operating Pressure for the Suction Side(MPa) 1.2 Sound Pressure Level dB (A) (H/M/L) 59 Sound Power Level dB (A) (H/M/L) 69 Dimension (W/H/D) (mm) 920/378/690 Dimension of Package (L/W/H)(mm) 994/428/750 52/57 Net Weight /Gross Weight (kg) R410A/1.5 Refrigerant Charge (kg) 5 Length (m) 30 Gas additional charge(g/m) ConneOuter ction Diameter Pipe Max Distance Liquid Pipe (mm) 6 Gas Pipe (mm) 12 Height (m) 5 Length (m) 10 In case of any change of data,please refer to the nameplate. 8 Component Name Air outlet Indoor Unit Decorative panel Front grill Air inlet Binding tape ! Remote controller Outdoor Unit Connecting pipe Air outlet 9 Floor Ceiling Series Air outlet Indoor Unit Decorative panel Front grill Air inlet Binding tape ! Remote controller Outdoor Unit Connecting pipe Air outlet Drainage pipe 10 Overall and Installing Dimension Overall and Installing Dimension of Indoor Unit Unit: mm 11 Floor Ceiling Series Overall and Installing Dimension of Outdoor Unit Handle Unit: mm Over 600 Over 600 Over 600 Over 600 Bolt Nut Wrench 12 Overall and Installing Dimension of Outdoor Unit Handle Unit: mm Over 600 Over 600 Over 600 Over 1000 Bolt Nut Wrench 13 Floor Ceiling Series Electrical Diagram ASF-09AL, ASF-12AL ASF-18AL In case of any change in the Electrical Diagram shown above, please follow the drawing on cabinet. 14 6 Controller Function Manual and Operation Instruction Controller Function Manual 1 Temperature Parameters Indoor preset temperature (Tpreset) Indoor ambient temperature (Tamb.) 2 Basic Functions Under each mode, once the compressor is started,it won't stop with the temperature spot within 6min and once stopped, it won't start with the temperature spot within 3min. (1) Cooling Mode 1.Cooling Conditions and Process When T amb. ≥ Tpreset +1℃, the unit will run under cooling mode, in which case the compressor and outdoor fan will be started and the indoor fan will run at preset speed. When T amb≤Tpreset -1℃, the unit will be stopped under cooling mode, in which case the compressor and outdoor fan will be stopped and the indoor fan will run at preset speed. When Tpreset -1℃<T amb.< Tpreset +1℃, the unit will maintain its original operating status. Under this mode, the temperature can be set within a range from 16 to 30 . The initial value is 26 . Tpreset +1℃ Start cooling Tamb Original operating status Tpreset -1℃ Stop cooling ≥6 min. ≥3 min. ≥6 min. Compressor Outdoor fan Preset speed Indoor fan Stop Run ( 2 ) Dehumidifying Mode 1.Dehumidifying Conditions and Process When T amb.> Tpreset +2℃, the unit will run under cooling mode, in which case the compressor and outdoor fan will be started and the indoor fan will run at low speed. When Tpreset -2℃≤T amb.≤Tpreset -2℃, the compressor, indoor unit and outdoor unit will run 6 minutes and stop 4 minutes in repeated cycle, while the indoor fan will run at low speed. When T amb.< Tpreset -2℃, the unit stops under cooling mode and compressor and outdoor fan will be stopped. Under dehumidifying mode, the temperature can be set within a range from 16 to 30℃.Initial value is 24 Tpreset +2℃ Tamb Start cooling Dehumidifying Tpreset -2℃ 6min. 6min. 4min. 4min. Compressor Outdoor fan low speed Indoor fan Run Stop 15 Stop cooling . Floor Ceiling Series ( 3 ) Fan Mode Under this mode,all loads of outdoor unit will be stopped.Malfunction can be detected but not handled. Indoor fan runs at preset speed.There are four kinds of fan speed for selection:Hi,Mid,Low, Auto. The auto fan speed is constant mid grade. The temperature is unadjustable, and is displayed. (4) Heating Mode 1.Heating Conditions and Process When air inlet temp sensor is used ,Tcompensation =2 , when manual controller temp sensor is used Tcompensation =0 . When T amb.≤Tpreset -1℃+ Tcompensation ,the unit will run under heating mode, compressor and outdoor fan will enter into running.The indoor fan will run in 45s at most.(If compressor is not started, the indoor fan will stop.) If T amb.≥Tpreset +1℃ Tcompensation the compressor and outdoor fan will be stopped and the 4-way valve is still energized. Indoor guide louver is at level position and indoor fan runs at blowing low speed.When the system is stopped, the indoor fan will stop after blowing 60s. When Tpreset -1℃ <T Tcompensation amb.< Tpreset +1℃ Tcompensation , the unit will maintain its original operating status. Under heating mode, the temperature can be set from 16 to 30℃.Initial value is 20 . Stop heating Tpreset +1℃ Tcompensation Original operating status Tpreset -1℃ Tcompensation amb 6 min. 6 min. 3 min. Start heating Compressor Outdoor fan Indoor fan Blow residual heat s Blow residual heat s Switchover valve Run Stop 2.Defrosting Conditions and Process Upon defrosting condition is met,compressor, indoor fan and outdoor fan will be stopped at the same time.3 s later, the 4-way valve will be closed.Thirty seconds after the 4-way valve is closed,the compressor will be started.If it is detected the defrosting is finished,the compressor will be stopped and the 4-way valve will be energized. After 30 seconds, the outdoor fan will be started and the indoor fan will run in 45s at most.The entire defrosting process won't exceed 10 min. (5) Auto Mode (only for the inodor unit with manual controller) Under this mode, the system will automatically select its run mode (cooling, dehumidifying or heating) with the change of ambient temperature. (6) Forced Running Mode (only for the inodor unit with manual controller) For the first energization of unit at off state, press TEMP button for 5 successive seconds into heating mode, in this case, the compressor and 4-way valve will start and indoor fan will run at high speed.The unit will automatically stop in 5min or can be stopped for testing by pressing ON/OFF button. For the first energization of unit at off state, press TEMP button for 5 successive seconds into cooling mode, in this case, the compressor and 4-way valve will start and indoor fan will run at high speed.The unit will automatically stop in 5min or can be stopped for testing by pressing ON/OFF button. 3 Other Control (1)Sleeping Function For floor ceiling series unit,its sleeping function only can be set by remote controller. Setting SLEEP function under COOL or DEHUMIDIFY mode, the preset temperature will automatically rise by 1℃ after 1 hour and rise by another 1℃ after 2 hours. Preset temperature will rise by 2℃ in total within 2 hours. After that, the unit will run at this preset temperature. Setting temp. Tset Tset Tset Tset 1Hr. 2Hrs. 16 2Hrs. above Setting SLEEP function under HEAT mode, the preset temperature will automatically decrease by 1℃ after 1hr and decrease by another 1℃ after 2 hours.Preset emperature will decrease by 2 ℃ in total within 2 hours. After that, the unit will run at this preset temperature. 2Hrs. above 1Hr. 2Hrs. Tset Tset Setting temp. Tset Tset No sleep function under FAN or AUTO mode. (2) Timer Function Timer function can be set only without malfucntion or protection.Once timer on/off has been set but malfunction or proctection happens and is cleared then, the timer will continue to display if the time hasn't reached. Timer ON function can be set when the unit is at off mode. Upon the time as set , the controller will run under preset mode. The interval of time setting is 0.5h and can be set within 0.5-24h in cycle. Timer OFF function can be set when the unit is at on mode. Upon the time as set , the system will be stopped.The interval of time setting is 0.5h and can be set within 0.5-24h in cycle. (3) Control of Swing Motor The swing will be reset when stopping or electrifying the unit. If swing motor is started and indor fan runs normally, the louver will swing to or fro .It will stop at present position if swing is stopped. When the unit is on without swing or blowing residual heat setting, the lover will stop at 60 degrees. If the unit stops for malfunction or defrosting during running process of indoor fan,the louver will stop at present position. (4) Buzzer When the controller is energized or receives valid key-press signal, the buzzer will give out a beep. (5) Automatic Control of Indoor Fan Speed Under cooling or heating mode, the indoor fan will automatically select its speed, i.e. high, medium or low, with the change of ambient temperature. Once a speed is activated, it can be switched in 30s at least according to the condition. (6) LED on Receive Board of Controller Power LED: It is bright when energized and black when de-energized. Cooling LED: It is bright under cooling,dehumidifying,auto cooling or auto dehumidifying mode and black under other modes. Heating LED: It is bright under heating or auto heating and black under other modes Dual-eight display of malfunction:Malfunction codes will be displayed according to priority level of them.(The manual controller will also display the codes.) 4. Protection Measures (1) Indoor Antifreeze Protection If antifreeze protection is detected under cooling or dehumidifying mode,the compressor, outdoor fan will stop, indoor fan will keep original state and LED will blink(or error code E2 is displayed).When antifreeze protection is solved and the compressor has been stopped for 3 min, outdoor fan and compressor will resume running. (2) High Pressure Protection(E1),Low Pressure Protection(E3) and Overload Protection (E5) No these function for this unit.The controller is current, so the external leading wire is shielded.If the connecting wire is loose, the unit will be stopped for controller potection and corresponding codes will be displayed. Handling Method:Cut off the power after stop of the unit.Open the electric box of outdoor unit.Connect the wires on mainboard terminals X14,X12,X10 and X15.Re-energize the unit. (3) Indoor High Temperature Protection If it is detected that the evaporator temperature (Tevap.) under heating mode is high, the indoor fan will automatically run at high speed.If the temperature continuously increases to specified value, the outdoor fan will stop.If temperature decreases, outdoor fan will start.If the temperature continuously decreases to normal value, the indoor fan will resume original setting fan speed. (4) Communication Malfunction If outdoor unit after electrifying shows that there is no return of signal from indoor unit in successive 30s , it indicates that communication malfunction of indoor unit exists, in which case, compressor and outdoor fan will stop.The 4-way valve will stop after the compressor has been stopped for 2 min during heating. 17 Floor Ceiling Series (4) Communication Malfunction If outdoor unit after electrifying shows that there is no return of signal from indoor unit in successive 30s , it indicates that communication malfunction of indoor unit exists, in which case, compressor and outdoor fan will stop.The 4-way valve will stop after the compressor has been stopped for 2 min during heating. If the indoor unit does not receive signal from outdoor unit in successive 1min,it indicates communication malfunction, in which case, indoor unit will stop and LED will blink.If display board does not receive signal from outdoor unit in successive 1min ,it indicates communication malfunction, in which case malfunction will display but the unit does not act.After communication resumes, the system will run under previous running mode. (5) Temperature Sensor Malfunction If short circuit or open circuit is detected, temp sensor exists. 1 Indoor Ambient Temp Sensor Malfunction If indoor temp sensor short-circuits or open-circuits, the indoor ambient temp will be forced to be 24 .The system has not any reaction except LED blinks or error code F0 is displayed.It will resume running after the malfunction is solved.Only malfunction is displayed under fan mode but indoor fan runs normally.It will disappear after the malfunction is solved. 2 Indoor Evaporator Temp Sensor Malfunction If indoor evaporator temp sensor short-circuits or open-circuits, the system will be stopped under cooling or dehumidifying mode and LED blinks or error code F1 is displayed.It will resume running and malfunction display will disappear after the malfunction is solved. All loads except 4-way valve are stopped under heating mode and LED blinks or error code F1 is displayed.The system will automatically resume running after the malfunction is solved. Only malfunction is displayed under fan mode but indoor fan runs normally.It will disappear after the malfunction is solved. 3 Condenser Temp Sensor Malfunction If condenser temp sensor short-circuits or open-circuits, the system will be stopped under cooling or dehumidifying mode and LED blinks or error code F2 is displayed.It will resume running and malfunction display will disappear after the malfunction is solved. All loads except 4-way valve are stopped under heating mode and LED blinks or error code F2 is displayed.The system will automatically resume running after the malfunction is solved. Only malfunction is displayed under fan mode but indoor fan runs normally.It will disappear after the malfunction is solved. 4 Outdoor Ambient Temp Sensor Malfunction If outdoor temp sensor short-circuits or open-circuits, the system will be stopped under cooling or dehumidifying mode and LED blinks or error code F3 is displayed.It will resume running and malfunction display will disappear after the malfunction is solved. All loads except 4-way valve are stopped under heating mode and LED blinks or error code F3 is displayed.The system will automatically resume running after the malfunction is solved. Only malfunction is displayed under fan mode but indoor fan runs normally.It will disappear after the malfunction is solved. (6) Exhaust High-temp Protection (E4) and Exhasut Temp Sensor Malfunction (F4) There is no this protection and exhaust temp sensor for this unit.But the controller is current, so if circuit malfunction is shielded (shielding abnormality or broken circuit of resistance,or connecting wire is loose or has poor contact or controller has malfunction) the above codes may be mis-displayed. (7) Memory Function Memorize mode, swing, setting temp, setting fan speed and ON/OFF. 18 7 Disassembly Procedures Disassembly Procedures for Indoor Unit Operating Procedures / Photos 1.Disassemble Front Grill and Filter Manually pull the clasp 2 of front grill downwards to open the front grill.Loose the clasp 1 with pincers to remove the front grill. Top the air filter to pull out the clasps at 2 sides and pull it forward to remove it. Grill Clasp 2 Fig.7-1,7-2 Front Grill Fig.7-1 Grill Clasp 1 Filter Fig.7-2 2.Disassemble Left and Right Decorative Panels Unscrew the 2 screws on the left and right decorative panels and them push the panels upwards forciblely to take them out. Fig.7-3,7-4 Screws Fig.7-3 19 Floor Ceiling Series Operating Procedures / Photos 3.Disassemble Front Panel Unscrew the 4 screws at the front panel and 3 screws in the sponge.Lift the front panel upwards to remove it. Fig.7.5 Fig.7-4 Screws Screws Fig.7.5 Screws 4.Disassemble Rear Side Plate (air outlet) Remove the flanneletteand unscrew the 2 screws at the rear side plate to remove it. Fig.7-6 Fig.7.6 Guide Louver 5.Disassemble Guide Louver Top the middle of guide louver and pull it out from the middle clasp and then bend the right and left axile bushes to take the guide louver out. Fig.7.7 Clasp Fig.7.7 20 Operating Procedures / Photos Axile Bush Fig.7-8 6.Disassemble Water Tray Sub-assy Unscrew the 4 screws fixing the right and left side of the water tray to remove it. Fig.7-9 Screw Fig.7-9 7.Disassemble Evaporator Assy Unscrew the 4 screws fixing the cover plate of evaporator.Pull out the 3 temp sensors on the pipes and then unscrew the 2 screws at the left side of evaporator to remove it by inclined lift. Screws Fig.7-10,7-11,7-12 Evaporator Cover Plate Screws Fig.7-10 21 Floor Ceiling Series Operating Procedures / Photos Temp Sensor Fig.7-11 Temp Sensor Fig.7-12 8.Disassemble Electric Box Assy Unscrew the 2 screws fixing the electric box cover to pull out the cover upwards.Loosen the wiring terminals of fan motor and guide louver motor and then remove the ambient temp sensor bound by the tie line at the side of elelctric box.At last unscrew the 3 screws fixing the electric box to remove it. Fig.7-13,7-14 Screws Screws Fig.7-13 Ambient Temp Sensor Fig.7-14 22 9.Disassemble Cross Flow Fan Loosen the clasps in and at the front and back of the propeller housing to remove it from the motor support.Unscrew the 1 screw fixing cross flow fan with a inner hexagon spanner to remove it. Fig.7-15,7-16 Propeller Housing Clasps Fig.7-15 Cross Flow Fan Screw Nuts Fig.7-16 10.Disassemble Motor Loosen the 4 nuts fixing the support to remove the motor sub-assy and then unscrew the 2 bolts onthe clamping band to remove the motor. Fig.7-17 Clamping Band Bolts 23 Fig.7-17 Floor Ceiling Series 7.2 Disassembly Procedures for Outdoor Unit Operating Procedures / Photos (9K,12K) 1.Disassemble Big Handle Unscrew the screw fixing the big handle,and then Screw remove it downwards to take it out. Big Handle Fig.7-18 2.Disassemble Top Cover Screw Unscrew the 2 screws fixing left side of top cover and the 1 screw fixing the right side to remove the top cover. Fig.7-19 Fig.7-19 3.Disassemble Rear Grill Unscrew the 4 screws fixing the rear grill to remove it. Fig.7-20 Rear Grill Screw Fig.7-20 24 Operating Procedures / Photos 4.Disassemble Front Panel Unscrew the 5 screws fixing the panel and dextrorotate the front panel to pull it out from groove. Fig.7-21 Screws Fig.7-21 5.Disassemble Electric Box Unscrew the 3 screws fixing the electric box, and then loosen the terminals of compressor and 4-way valve to take out the electric box. Fig.7-22 Fig.7-22,7-23 Screw Electric Box Fig.7-23 6.Disassemble Right Side Plate Right Side Plate Unscrew the 5 screws fixing the right side plate to remove it. Fig.7-24 Screws Fig.7-24 25 Floor Ceiling Series Operating Procedures / Photos 7.Disassemble Axial Flow Fan Axial Flow Fan Loosen the fastening nut fixing the axial flow fan with a spanner ,and then take out the nut,spring gasket and flap gasket in turn. Nut Fig.7-25 Fig.7-25 8.Disassemble Motor and Motor Support Unscrew the 4 screws fixing the motor to take out the motor,and then unscrew the 2 screws fixing the motor support to take it out. Fig.7-26 Screws Screws Fig.7-26 9.Disassemble Four-way Valve Unscrew the fastening nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. (Note:Refrigerant Four-way valve coil should be discharged firstly.) Four-way valve Welding process should be as quick as possible and keep wrapping cotton wet all the time. Be sure not to burn out the lead-out wire of compressor. Fig.7-27 Weld spots Fig.7-27 26 Operating Procedures / Photos 10. Disassemble Capillary Main Capillary Respectively unsolder the weld spots of main capillary and auxiliary capillary to take off the capillary. Fig.7-28 Auxiliary Capillary Fig.7-28 11.Disassemble Gas and Liquid Valves Unscrew the two bolts fixing gas valve and liquid valve.Unsolder weld spots between gas valve and Weld spots and air-return pipe to remove the gas valve. Unscrew the two bolts fixing liquid valve. Unsolder weld spots between liquid valve and capillary to Liquid Valve remove the liquid valve. (Note:During unsoldering ,wrap the valves with wet cloth to avoid damage for high temperature.) Screws Gas Valve Fig.7-29 Fig.7-29 12.Disassemble Compressor Unscrew the three foot-nuts at the foot of the compressor. Unsolder the suction and the discharge pipes of the compressor,and then carefully remove the pipes to Compressor take out the compressor. Fig.7-30 Foot Nuts Fig.7-30 27 Floor Ceiling Series 7.3 Disassembly Procedure of Outdoor Unit Operating Procedures / Photos (18K) 1.Disassemble Top Cover Top Cover Unscrew the screws fixing the top cover, and then lift the top cover to remove it. Screws Fig.7-31 Fig.7-31 2.Disassemble Handle Unscrew the screw fixing the handle,and then push it downwards to take it out. Handle Fig.7-32 Screw Fig.7-32 3.Disassemble Rear Side Plate Sub-assay Rear Side Plate Rear Grill Unscrew the screws fixing the rear grill and rear side plate to remove rear side plate sub-assy after removing rear grill. Fig.7-33 Screws Fig.7-33 28 Operating Procedures / Photos 4.Disassemble Front Grill Unscrew the screws fixing the front grill ,and then lift it upwards to remove it. Front Grill Fig.7-34 Screw Fig.7-34 5.Disassemble Cabinet Unscrew the screws fixing the cabinet to remove it. Cabinet Fig.7-35 Fig.7-35 6.Disassemble Electric Box Sub-assy Screw Unscrew the 4 screws fixing electric box to pull out the connection line between fan motor and electric Electric Box box and then lift the electric box to take it out. Fig.7-36 Fig.7-36 29 Floor Ceiling Series Operating Procedures / Photos 7.Disassemble Gas and Liquid Valves Unsolder the pipeline connecting with valves ( to prevent soldering gun from burning out the chassis).Unscrew 2 bolts fixing gas valve ,and then unsolder the weld spot between pipeline and gas valve to remove gas valve. Unscrew the 2 bolts fixing liquid valve ,and then unsolder the weld spots between pipeline and liquid valve to remove liquid valve. (Note:During unsoldering ,wrap the valves with wet cloth to avoid damage for high temperature.) Fig.7-37 Liquid Valve Bolts Gas Valve Fig.7-37 8.Disassemble Axial Flow Fan Unscrew the nut fixing the fan with a spanner to take out the fan . Axial Flow Fan Fig.7-38 Nut Fig.7-38 9.Disassemble Outdoor Motor Motor Wire Unscrew the screws fixing the motor support ,and then lift it upwards to remove it. Unscrew the screws Motor fixing the motor and pull out the connection line between Terminal Screw it and electric box to remove it. of Motor Fig.7-39 Motor Support Clapboard Terminal Screws Fig.7-39 30 Operating Procedures / Photos 10.Disassemble Four-way Valve Weld spots Only for cooling and heating unit Unscrew the fixing nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. Welding process should be as quick as possible and keep wrapping cotton wet all the time. Be sure not to burn out the Four-way Valve lead-out wire of compressor. Fig.7-40 Fig.7-40 11.Disassemble Capillary Capillary Unsolder the weld spots of capillary,valve and outlet pipe of condenser to remove the capillary.Prevent welding slag from blocking the capillary. Fig.7-41 Fig.7-41 12.Disassemble Compressor Unsolder the pipeline connecting the compressor, and then unscrew the 3 foot-nuts fixing conpressor to remove it. Fig.7-42 Foot-nut Fig.7-42 31 Floor Ceiling Series Exploded View and Components and Parts List 1.Exploded View of Indoor Unit 32 2.Components and Parts List of Indoor Unit No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Description Rear Side Plate Handle Left Decoration Plate Rear Side Plate of Air Outlet Louver Right Decoration Plate Shaft of Louver II Louver Support Shaft of Louver I Louver Fixer Swing Louver Connecting Lever Connecting Lever Right Swing Motor Fixer Right Fixing Plate of Evaporator Foam of Right Side Plate Right Fixing Plate Right Decoration Panel Pipe Clamp Plate Capacitor CBB611A 1uF/450 Transformer 57X25C Electric Box Main PCB Z7A351 Terminal Board RS9413G Wire Base Wire Clamp Fuse 5A 250VAC Cover of Electric Box Pipe Clip Drainage Pipe Display Board 5T52 Electric Box Part Code ASF-09AL 01302013 26232001 261124151 01302015 1051953201 261124161 10512026 24212019 10512025 24212018 10512027 10582009 10582008 26152006 01072411 12312404 01332404 26112027 0107243701 33010035 43110237 01402407 30227105 42010178 24253001 24253002 46010013 01412408 70812001 05235433 30545654 20102138 33 Price Code ASF-09AL AX AD AE AK AN AE AB AC AB AC AB AC AC AD AD AD AH AH AC AE AM AG BF AF AC AC AA AF AB AE AW AD Qty 1 4 1 1 1 1 2 2 1 1 12 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Floor Ceiling Series No. 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Description Front Grill Clip 1 Filter Front Grill Front Grill Clip 2 Buttons Panel Front Panel Water Tray Panel Motor Support Left Decoration Panel Left Fixing Plate Left Side Foam Left Fixing Plate of Evaporator Motor Clamp Step Motor MP35CA Left Swing Motor Fixer Evaporator Assy Liquid-intake Pipe Components Air Collecting Pipe Components Temp Sensor 20K Temp Sensor Insert Water Lead Panel Cover of Evaporator Fixed Mount Centrifugal Fan Rear Snail Shell Front Snail Shell Axes Connector Bar Clasp Hoop Motor PG10H Remote Controller Connecting Cable Connecting Cable Signal Cable Part Code ASF-09AL 26252002 11122013 22412010 76512210 201620041 01413008 01272205P 01709532 26112028 01332405 12312403 01072410 26112026 15212402 26152005 01032466 03222465 03533200 39000194 42020063 01362001 01072409 01708763 10312401 22202032 22202031 390001215 70819522 70819521 15707302 305125063 400205473 40020540 4001023214 The above data are subject to change withuot notices. 34 Price Code ASF-09AL AB AD AG AC AE AF AZ AT AH AH AD AD AC AF AD BG AX AW AD AD AD AC AK AS AF AG AD AD AD BE AT AN AN AM Qty 4 2 2 4 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 2 2 2 1 4 1 1 1 1 1 1 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Description Rear Side Plate Handle Left Decoration Plate Rear Side Plate of Air Outlet Louver Right Decoration Plate Shaft of Louver II Louver Support Shaft of Louver I Louver Fixer Swing Louver Connecting Lever Connecting Lever Right Swing Motor Fixer Right Fixing Plate of Evaporator Foam of Right Side Plate Right Fixing Plate Right Decoration Panel Pipe Clamp Plate Capacitor CBB611A 1.5uF/450 Transformer 57X25C Electric Box Main PCB Z7A351 Terminal Board RS9413G Wire Base Wire Clamp Fuse 5A 250VAC Cover of Electric Box Pipe Clip Drainage Pipe Display Board 5T52 Electric Box Part Code ASF-12AL 01302013 26232001 261124151 01302015 1051953201 261124161 10512026 24212019 10512025 24212018 10512027 10582009 10582008 26152006 01072411 12312404 01332404 26112027 0107243701 33010020 43110237 01402407 30227105 42010178 24253001 24253002 46010013 01412408 70812001 05235433 30545654 20102138 35 Price Code ASF-12AL AX AD AE AK AN AE AB AC AB AC AB AC AC AD AD AD AH AH AC AE AM AG BF AF AC AC AA AF AB AE AW AD Qty 1 4 1 1 1 1 2 2 1 1 12 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Floor Ceiling Series No. 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Description Front Grill Clip 1 Filter Front Grill Front Grill Clip 2 Buttons Panel Front Panel Water Tray Panel Motor Support Left Decoration Panel Left Fixing Plate Left Side Foam Left Fixing Plate of Evaporator Motor Clamp Step Motor MP35CA Left Swing Motor Fixer Evaporator Assy Liquid-intake Pipe Components Air Collecting Pipe Components Temp Sensor 20K Temp Sensor Insert Water Lead Panel Cover of Evaporator Fixed Mount Centrifugal Fan Rear Snail Shell Front Snail Shell Axes Connector Bar Clasp Hoop Motor PG10H Remote Controller Connecting Cable Connecting Cable Signal Cable Part Code ASF-12AL 26252002 11122013 22412010 76512210 201620041 01413008 01272205P 01709532 26112028 01332405 12312403 01072410 26112026 15212402 26152005 01032467 03222519 03533425 39000194 42020063 01362001 01072409 01708763 10312401 22202032 22202031 390001215 70819522 70819521 15707302 305125063 400205473 40020540 4001023214 The above data are subject to change withuot notices. 36 Price Code ASF-12AL AB AD AG AC AE AF AZ AT AH AH AD AD AC AF AD BG AX AW AD AD AD AC AK AS AF AG AD AD AD BE AT AN AN AM Qty 4 2 2 4 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 2 2 2 1 4 1 1 1 1 1 1 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Description Rear Side Plate Handle Left Decoration Plate Rear Side Plate of Air Outlet Louver Right Decoration Plate Shaft of Louver II Louver Support Shaft of Louver I Louver Fixer Swing Louver Connecting Lever Connecting Lever Right Swing Motor Fixer Right Fixing Plate of Evaporator Foam of Right Side Plate Right Fixing Plate Right Decoration Panel Pipe Clamp Plate Capacitor CBB611A 3uF/450 Transformer 57X25C Electric Box Main PCB Z7A351 Terminal Board RS9413G Wire Base Wire Clamp Fuse 5A 250VAC Cover of Electric Box Pipe Clip Drainage Pipe Display Board 5T52 Electric Box Part Code ASF-18AL 01302013 26232001 261124151 01302015 1051953201 261124161 10512026 24212019 10512025 24212018 10512027 10582009 10582008 26152006 01072411 12312404 01332404 26112027 0107243701 33010027 43110237 01402407 30227105 42010178 24253001 24253002 46010013 01412408 70812001 05235433 30545654 20102138 37 Price Code ASF-18AL AX AD AE AK AN AE AB AC AB AC AB AC AC AD AD AD AH AH AC AE AM AG BF AF AC AC AA AF AB AE AW AD Qty 1 4 1 1 1 1 2 2 1 1 12 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Floor Ceiling Series No. 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Description Front Grill Clip 1 Filter Front Grill Front Grill Clip 2 Buttons Panel Front Panel Water Tray Panel Motor Support Left Decoration Panel Left Fixing Plate Left Side Foam Left Fixing Plate of Evaporator Motor Clamp Step Motor MP35CA Left Swing Motor Fixer Evaporator Assy Liquid-intake Pipe Components Air Collecting Pipe Components Temp Sensor 20K Temp Sensor Insert Water Lead Panel Cover of Evaporator Fixed Mount Centrifugal Fan Rear Snail Shell Front Snail Shell Axes Connector Bar Clasp Hoop Motor PG40F Remote Controller Connecting Cable Connecting Cable Signal Cable Part Code ASF-18AL 26252002 11122013 22412010 76512210 201620041 01413008 01272205P 01709532 26112028 01332405 12312403 01072410 26112026 15212402 26152005 01032468 03222520 03533428 39000194 42020063 01362001 01072409 01708763 10312401 22202032 22202031 390001215 70819522 70819521 15707302 26112028 400205473 40020540 4001023214 The above data are subject to change withuot notices. 38 Price Code ASF-18AL AB AD AG AC AE AF AZ AT AH AH AD AD AC AF AD BH AX AW AD AD AD AC AK AS AF AG AD AD AD BE AT AN AN AM Qty 4 2 2 4 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 2 2 2 1 4 1 1 1 1 1 1 3.Exploded View of Outdoor Unit (9K,12K) 39 Foor Ceiling Series 4.Components and Parts List of Outdoor Unit (9K,12K) No. Description 1 2 3 4 5 6 Front Grill Front Plate Metal Base 4-way valve 4-way valve coil 4-way rever -sing valve component Compressor ASG108CV-B7AT Compressor Gasket Valve Support Valve 3/8" (R410A) Valve 1/4" (R410A) Big Handle Tapping Screw Right Side Plate Assy Capillary Assy Wire Clamp Wire Clamp Terminal Board Electric Plate Assy Mat Main Board WZ4C352 Terminal Board Capacitor AC Contactor Transformer Comp Capacitor Capacitor Clamp Isolation Sheet Assy Condenser Assy Rear Grill Electric Box Cover Top Cover Motor Support Axial Flow Fan Motor FW30K Drainage Connecter 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Part Code ASF-09AL 22413011 01533007 01203589P 430004022 43000400 03023917 Price Code ASF-09AL AL AM AR AX AP AW Qty 00120145 BN 01713041 07100005 07100003 26233433 70140165 01302004 03103379 71010103 71010003 42010255 01409070 / 30224033 42011103 33010025 44010245 43110240 33010743 02143401 01239052 01135005 01473030 01413048 01253443 017030511 10333414 15013067 06123401 AD AG AG AE AC AM AW AB AB AD AH / BA AD AE AT AL AK AB AK BD AG AF AH AL AM AU AA 1 3 1 1 1 1 4 1 1 1 1 1 1 / 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 The above data are subject to change withuot notices. 40 1 1 1 1 1 1 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Description Front Grill Front Plate Metal Base 4-way valve 4-way valve coil 4-way rever -sing valve component Compressor C-RV146H1C Compressor Gasket Valve Support Valve 1/2" (R410A) Valve 1/4" (R410A) Big Handle Tapping Screw Right Side Plate Assy Capillary Assy Wire Clamp Wire Clamp Terminal Board Electric Plate Assy Mat Main Board WZ4C352 Terminal Board Capacitor AC Contactor Transformer Comp Capacitor Capacitor Clamp Isolation Sheet Assy Condenser Assy Rear Grill Electric Box Cover Top Cover Motor Support Axial Flow Fan Motor FW30K Drainage Connecter Part Code ASF-12AL 22413011 01533007 01203591P 430004032 43000400 03023918 Price Code ASF-12AL AL AM AR BA AP AW Qty 00103712 BQ 01713041 07100006 07100003 26233433 70140165 01302004 03103379 71010103 71010003 42010255 01409070 / 30224033 42011103 33010025 44010245 43110240 33000018 02143401 01239052 01135005 01473030 01413048 01253443 017030511 10333414 15013067 06123401 AD AG AG AE AC AM AW AB AB AD AH / BA AD AE AT AL AK AB AK BD AG AF AH AL AM AU AA 1 3 1 1 1 1 4 1 1 1 1 1 1 / 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 The above data are subject to change withuot notices. 41 1 1 1 1 1 1 Floor Ceiling Series 5.Exploded View of Outdoor Unit (18K) 42 6.Components and Parts List of Outdoor Unit (18K) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Description Front Grill left Handle Front Plate Axial Flow Fan Metal Base Valve Support Motor FW60L Motor Support Plate Condenser Assy Ambient Sensor 15K Top Cover Valve 1/2" Valve 1/4" Rear Grill Isolation Sheet Plate Tube Sensor 20K Rear Side Plate Handle Assy Capacitor clamp Capacitor CBB65 60uF/450V Transformer 57X25D AC Contactor CJX9B-25S/D Terminal Board 2-8 Capacitor CBB61 3uF/450V Main Board WZ4C352 Wiring Terminal Wire Clamp Wire Clamp Electric Plate Assy Electric Box Cover 4 Way Valve Coil 4 Way Valve Compressor ASH218SV-C8LU Rubber foot of compressor Part Code ASF-18AL 22415001 26235401 01305017 10335253 01203590 01715006 15013063 01705107 011334641 3900012132 01255001 071302335 07130208 01473006 01233033 3900012128 01305029 26235255 02141375 33000039 43110240 44010245 42011103 33010027 30224033 42010255 71010003 71010103 01403636 01413079 430004002 430004032 00103006 76710202 The above data are subject to change withuot notices. 43 Price Code ASF-18AL AL AC AM AP AU AD AZ AL BF AD AH AG AG AG AK AD AM AE AB AM AL AT AD AE BA AD AB AB AH AE AM BA BT AE Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Floor Ceiling Series 9 Trouble-Shooting When set short-circuiter as “ ON ” , it trips immediately Trip of circuit breaker or burn-out of fuse Air –conditioning unit cannot be started When turning the air-conditioning unit to the “ON”status, trip of circuit breaker occurs several minutes later When air-conditioning unit is powered on, there is no action (when the unit is plugged in, buzzer does not sound and there is no action after using the remote controller to start the unit) Remote controller does not receive signal (when unit is powered on, buzzer shall sound, unless buzzer is damaged) No power supply Check insulation resistance for grounding; Confirm if air-conditioning unit has electrical leakage or is short-circuited Failure of air-conditioning unit or component insulation failure, short circuit or electricle leakage owing to insulation puncture after heating, measure insulation resistance or check the components one by one to find the ones with failure; failure of circuit breaker itself, replace it. Check power supply line Power plug is not firmly seated or connection is poor Check and secure the plug to ensure firm contact Controller fuse burned out Replace controller fuse Connection line of transformer is loose or suffers from poor plugging, or there is transformer failure Secure line connections; measure output voltage of transformer and replace transformer if it is incorrect Controller is damaged Replace controller Batteries of remote controller are running out of power Replace battery Remote controller failure Replace remote controller Receiving head is loose or plug connection is poor Receiving damaged head is Fix the receiving head at correct position. Replace receiving head Check power voltage. If the voltage is 10% than rated voltage, check the cause, and improve the power supply conditions such as adding regulated power supply. Power voltage is too low 44 Set temperature appropriate is Adjust the set temperature not Check if the cooling (heating) load is appropriate Check the forecasted cooling (heating) load Leakage of refrigerant or insufficient refrigerant Poor cooling (heating) effect Failure of refrigerant flow Leakage between internal high pressure and low pressure sections of compressor Replace compressor 4-way valve failure Replace 4-way valve Partial block in capillary Replace capillary Observe the condensation condition of evaporator or the reading of high pressure meter to judge if the system is blocked; deal with the system accordingly Block in cooling system The thermal insulation of big pipe and small pipe shall be separate and sound; joint and bare position of copper pipe shall also have thermal insulation Poor thermal insulation of connecting pipe between indoor unit and outdoor unit Insufficient air circulation volume Block in outdoor heat exchanger Wash away dust on surface of heat exchanger Block in air filter Clean filter Fan speed was set too low Set fan speed as high or medium Fan speed lower Capacitor is damaged Replace capcitor Motor is damaged Replace motor turns Mounting position of outdoor unit is inappropriate Outdoor temperature is too high Check leakage, carry out vacuum-pumping after repairing leakage and charge refrigerant according to requirements Outdoor unit shall be installed in a place with good ventilation Install proper weather screen; it is suggested to replace air-conditioner unit with one of higher capacity in case the best available cooling effect does not satisfy needs Indoor space is not sufficiently closed, or people enters or leave the room frequently, or there is heating equipment operating in the room 45 Keep the indoor space as closed as possible, do not use electrical appliance generating large amount of heat Floor Ceiling Series When air supply mode is selected, the fan does not operate When in cooling or heating mode, compressor operates but outdoor fan does not operate When in cooling or heating mode, outdoor fan operates but compressor does not operate Indoor fan motor burned out or there is wire breakage or failure of overheating protector Replace fan motor or components with failure The internal overheating protector frequently breaks as overheating is caused by abnormity of motor Replace fan motor Wrong line connection Correctly connect lines according to electrical diagram Open circuit or damage of fan capacitor Replace it withfan capacitor of the same model and spec Outdoor fan motor is damaged Replace fan motor Wrong line connection Correctly connect lines according to electrical diagram Outdoor fan capacitor is damaged Replace fan capacitor Compressor failure Replace Compressor Operating capacitor of compressor is damaged Replace capcitor Voltage is too low or too high It is suggested to equip voltage regulator Wrong line connection Correctly connect lines according to electrical diagram Use uniersal meter to check if contacts of compressure not overheated are conducting; replace protector in case of non-conducting conditions Failure of protector itself Compressor is overheated so protector is activated Insufficient or too much refrigerant Adjust refrigerant amount Capillary is blocked so air intake temperature is too high Replace capillary Compressor does not operate smoothly (seized or jammed), air discharge valve is damaged Replace Compressor Failure of protector itself Replace protector Torque of swing motor is insufficient Swing louver does not run Fisrtly check if line connections have fault, if no, replace components at failure position Wrong line connection Controller is damaged (IC2003 is damaged, swing relay cannot close 46 Abnormal sound and vibration Fan of indoor unit touches other positions Adjust fan position Foreign articles inside the indoor unit Remove foreign articles Vibration of compressor is violent Adjust support foot mat of compressor, tighten loose bolts Pipes of outdoor unit bump together Separate bumping pipes Metal plates bump together inside the unit 1. Tighten connection screws 2. Attach vibration damping gum between metal plates Indoor fan bumps cabinet Adjust fan position Abnormal sound compressor from inside Replace Compressor Abnormal electromagnetic noise from 4-way valve when in heating operation Internal short circuit of solenoid valve, replace solenoid valve Block or breakage of drainage pipe Replace drainage pipe The refrigerant pipe joint is not wrapped firmly Wrap and bind it again firmly Water leakage 47
advertisement
Key Features
- Microcomputer control
- Low noise operation
- Complete unit of low height
- 3-speed motor
- High cooling and heating capacity
- Compression-moulded water tray
- Pressure-viscosity insulating material
- Prolonged filter life
- Automatic fan speed control
- Sleeping function