Below you will find brief information for Console Connector Kit 8253, Speaker 251, Speaker 351, Hammond A100, Hammond M100, Hammond E100. This kit is used to connect a LESLIE Speaker to a HAMMOND organ. It contains all the necessary parts to connect the speaker to the organ, including the console connector, cables, screws, and instructions. The installation process is straightforward and can be completed in a few minutes. Once installed, you will be able to enjoy the full sound of your LESLIE speaker.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
LESLIE CONSOLE CONNECTOR KIT 8253 INSTALLA TION INSTRUCTIONS
FOR USE WITH: HAMMOND Models A100, M100, or E100
LESLIE Speaker 251 or 351
MULTIPLE SPEAKER INSTALLATION: For complete information, see the service manual of the LESLIE Speaker to be added.
Contents of Kit:
1 -Console Connector
1 -Console Adapter
1 -6 Conductor Cable
1 -Oiler
011874
062091
017277
053025
1 -Instructions
2 -Screws, 8 x 1/2
034686
029132
4 -Screws, 6 x 1/2, Blk Oxide 029124
8 -Wire Nuts 028076
2 -Connector, Tab, Male
2 -Connector, Tab, Female
5 -Insulated Staples
029371
029389
028464
1 -Tremolo Control
024976
024984
024992
1 -Echo Control
011882
011890
011908
Brown
Ebony
Ivory
Brown
Ebony
Ivory
To Install the Kit:
1. Attach the Echo and Tremolo controls to the wooden rail in front of the lower manual with the black oxide screws provided. Use the two mounting holes which best center the screws in the rail.
2. Remove the console dust cover, and pass the control cables into the console by one of the following methods:
A100, M100: Clip the red and green interceptor plugs and sockets off the Echo control cable and strip the wires 3/8". Push a small screwdriver over the felt dust seal between the lower manual and the knee panel. Push the cables through this opening into the console. From the back of the console, reach behind the tone generator and pull the cables through .
E100: Remove the knee plate under the lower manual, and pass the control cables into the console through this opening. Cut a small notch in the edge of the knee plate to accommodate the cables, then replace it.
3. Pass the switch cables through the slot in the rear edge of the shelf into the lower compartment.
4. Position the console connector near the power amplifier, so that the power and control cables will reach. Install it with the wood screws provided.
Page 1 of 4
5. A100, M100: Cut the green lead which connects the amplifier output to the main speakers. (See "A" & "B" on Fig. 1 & 2.) Remove 3/8" of insulation from each of the cut ends. Connect the amplifier end of this lead to the red lead from the Echo control with a wire nut. Connect the speaker end of the lead to the green lead from the Echo control. (See "B" on Figs. 1 & 2.)
E100: Remove the green speaker plug from the chassis socket on the left-hand apron of the power amplifier. (See "A" on Fig. 3.) Fit this plug intothe green interceptor socket onthe Echo switch cable, and fit the interceptor plug into the chassis socket.
6. A100, Ml00: a Disconnect the reverberation input lead (green on A100 and M100A; red on
M100) from the main speakers. (See "C" on Figs. 1 & 2.) Strip and connect it to the orange lead from the Echo control with the wire nut provided.
b Detach the "hot" lead (gray or blue) from the reverberation speaker terminal, strip it about 3/8", and connect it to the blue lead from the Echo control with the wire nut provided. (See "D" on Figs. 1 & 2.) c Solder the yellow Echo control lead to the "hot" reverberation speaker terminal.
(See "E" on Figs. 1 & 2.)
E100: Remove red speaker plug from the chassis socket on the left apron of the power amplifier. (See "B" on Fig. 3. ) Fit this plug into the red interceptor socket on the Echo switch cable; then connect red interceptor plug to the red chassis socket. Fold back the orange wire attached to the Echo switch. Insulate it with the plastic sleeve provided. It is not used in this installation.
7. A100: Plug the Console Connector pigtail into the 5 contact socket on the rear apron of the power amplifier chassis. (See "F" on Fig. 1.)
M100: Cut the 5 pin plug off the Console Connector pigtail and strip all three leads about 1/4". Solder the brown POT cord to the outside AC terminals under the metal cover on the left-hand side of the rear apron of the power amplifier. (See
"F" on Fig. 2.) Fasten the red lead to any convenient ground point on the amplifier chassis. (See "F" on Fig. 2.)
E100: Plug the Console Connector pigtail into the 062091 adapter and insert it into the 7 contact socket on the rear apron of the amplifier chassis. (See "C" on Fig.
3.)
8. Connect the brown lead from the Echo control to the brown lead from the Console
Connector with the wire nut provided. (See "G" on Figs. 1 & 2; "D" on Fig. 3.)
9. Connect the black lead from the Echo control to the black lead from the Console
Connector with the wire nut provided. (See "H" on Figs. 1 & 2; "E" on Fig. 3.)
Page 2 of 4
10. Connect the POT cord from the Tremolo control to the short POT cord on the
Console Connector with the wire nuts provided. (See "I" on Figs. 1 & 2; "G" on Fig.
3.)
11. Plug the speaker cable into the 6 contact socket on the Console Connector. (See
"J" on Figs. 1 & 2; "H" on Fig. 3. )
12. Adjust the speaker volume control as indicated in the manual. Set speaker load resistor to OPEN. The installation is now complete.
13. Replace the console dust cover and back.
011874 CONSOLE CONNECTOR PARTS LIST:
C1 Capacitor, Disk, .01 mf, 1000V, 20% 060467
P1 Plug, 5 Pin, w/o Plate
R1,2 Resistor, 80hm, 10W, Wire Wound
S1 Socket,6 Contact, w/Mtg Plate
013060
010934
060459
Control Switch Parts List:
Echo Control
Echo Switch Case
029199 Brown
029207 Ebony
029215 Ivory
Switch Retainer (2 req'd)
P2 Plug Hsing, Red-Amp
S2 Socket Hsing, Red-Amp
Switch Case Cover
048702 Brown
048710 Ebony
048728 Ivory
048116
016576
016568
P2 Insert, Male-Amp (2 req'd) 010421
S2 Insert, Female-Amp (2 req'd) 010397
P3 Plug Hsing, Grn-Amp
S3 Socket Hsin9, Grn-Amp
010389
010371
P3 Insert, Male-Amp (2 req'd) 010421
S3 Insert, Female-Amp (2 req'd) 010397
Switch Knob
048066 Brown
048074 Ebony
Switch Only 029173
Tremolo Control
Tremolo Switch Case
012260 Brown
012278 Ebony
012286 Ivory
Switch Retainer (2 req'd)
Switch Only
Switch Case Cover
048702 Brown
048710 Ebony
048728 Ivory
048108
042911
Switch Knob
048066 Brown
048074 Ebony
Ordering Parts:
Standard hardware, connectors, and electronic components should be purchased locally. Non-standard items may be obtained through a Leslie speaker dealer. Orders should include part numbers shown above.
Page 3 of 4
Page 4 of 4
advertisement
Key Features
- Connect LESLIE Speaker to HAMMOND organ
- Includes Console Connector, cables, screws
- Straightforward installation
- Enhances sound quality
- Provides control over Echo and Tremolo effects
- Compatible with A100, M100 and E100 Hammond organs
- Compatible with 251 and 351 Leslie speakers