Dell OpenManage Software Version 10.2.0.0 software Reference Guide

Add to my manuals
441 Pages

advertisement

Dell OpenManage Software Version 10.2.0.0 software Reference Guide | Manualzz

Dell EMC OpenManage SNMP Reference

Guide Version 10.2.0.0

December 2021

Rev. A01

Notes, cautions, and warnings

NOTE: A NOTE indicates important information that helps you make better use of your product.

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

© 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.

Contents

Chapter 1: Introduction................................................................................................................. 6

What is new in this release................................................................................................................................................6

Supported SNMP Versions................................................................................................................................................7

Managed Object Used in This Document.......................................................................................................................7

Server Administrator Instrumentation MIB................................................................................................................... 8

Server Administrator Baseboard Management Controller, ASF MIB......................................................................9

Server Administrator Storage Management MIB........................................................................................................ 9

Server Administrator Field Replaceable Unit MIB...................................................................................................... 10

Basic Terminology..............................................................................................................................................................10

Frequently Used Terms in Variable Names.................................................................................................................. 10

Tables.....................................................................................................................................................................................11

Section Organization.........................................................................................................................................................12

Other Documents You May Need.................................................................................................................................. 13

Accessing support content from the Dell EMC support site.............................................................................13

Introduction to the Server Administrator SNMP Subagent.................................................................................... 14

Management Information Base Object Identifiers............................................................................................... 15

SNMP Security............................................................................................................................................................. 15

SNMP Traps.................................................................................................................................................................. 16

System Battery Table....................................................................................................................................................... 16

Amperage Probe Table .................................................................................................................................................... 17

Power Unit Group............................................................................................................................................................. 20

Power Supply Table ......................................................................................................................................................... 22

Power Usage Table ..........................................................................................................................................................25

Voltage Probe Table ........................................................................................................................................................ 28

System Information Group...............................................................................................................................................31

Chapter 2: Server Administrator Group....................................................................................... 36

Instrumentation MIB Version Group............................................................................................................................. 36

Management Information Base Major Version Number..................................................................................... 37

Management Information Base Minor Version Number..................................................................................... 37

Management Information Base Maintenance Version Number........................................................................37

Systems Management Software Group.......................................................................................................................37

Systems Management Software............................................................................................................................. 38

Systems Management Software Variable Values................................................................................................40

System State Group.......................................................................................................................................................... 41

System State Group Table.........................................................................................................................................41

Chassis Information Group..............................................................................................................................................54

Chassis Information Group Tables...........................................................................................................................54

Chassis Information Group Variable Values...........................................................................................................79

Operating System Group.................................................................................................................................................89

Operating System Memory Table............................................................................................................................89

System Resource Group...................................................................................................................................................91

System Resource Group Tables............................................................................................................................... 91

System Resource Group Variable Values............................................................................................................. 103

Contents 3

Power Group.....................................................................................................................................................................105

Power Group Tables..................................................................................................................................................106

Power Group Variable Values..................................................................................................................................129

Thermal Group..................................................................................................................................................................135

Thermal Group Tables...............................................................................................................................................136

Thermal Group Variable Values.............................................................................................................................. 145

Remote Flash BIOS Group.............................................................................................................................................146

Remote Flash BIOS Group Table............................................................................................................................146

Remote Flash BIOS Variable Values...................................................................................................................... 148

Port Group.........................................................................................................................................................................149

Port Group Tables......................................................................................................................................................149

Port Group Variable Values..................................................................................................................................... 169

Device Group..................................................................................................................................................................... 171

Device Tables.............................................................................................................................................................. 172

Device Group Variable Values................................................................................................................................. 214

Slot Group.........................................................................................................................................................................235

System Slot Group Table........................................................................................................................................ 235

System Slot Variable Values................................................................................................................................... 238

Memory Group.................................................................................................................................................................243

Physical Memory Tables.......................................................................................................................................... 243

Memory Group Variable Values............................................................................................................................. 256

BIOS Setup Control Group........................................................................................................................................... 259

BIOS Setup Control Group Tables........................................................................................................................ 259

BIOS Group Variable Values................................................................................................................................... 280

Local Response Agent Group.......................................................................................................................................286

LRA Group Tables..................................................................................................................................................... 286

Local Response Agent Variable Values................................................................................................................ 289

Cost of Ownership Group.............................................................................................................................................290

Cost of Ownership Group Tables..........................................................................................................................290

Cost of Ownership Variable Values....................................................................................................................... 313

Cluster Group .................................................................................................................................................................. 314

Cluster Group..............................................................................................................................................................314

Cluster Group Variable Values................................................................................................................................ 316

Baseboard Management Controller Group................................................................................................................ 317

Baseboard Management Controller Group Tables............................................................................................. 317

Baseboard Management Controller Group Variable Values............................................................................325

Field Replaceable Unit Group.......................................................................................................................................328

Field Replaceable Unit Group Tables....................................................................................................................328

Field Replaceable Unit Group Variable Values....................................................................................................330

Chapter 3: Storage Management Group..................................................................................... 331

Storage Management Group.........................................................................................................................................331

Storage Management Information Group................................................................................................................. 332

Global Data Group...........................................................................................................................................................333

Physical Devices Group................................................................................................................................................. 336

Controller Table......................................................................................................................................................... 337

Channel Table............................................................................................................................................................. 351

Enclosure Table......................................................................................................................................................... 354

Array Disk Table.........................................................................................................................................................362

Array Disk Enclosure Connection Table............................................................................................................... 374

4 Contents

Array Disk Channel Connection Table.................................................................................................................. 376

Fan Table..................................................................................................................................................................... 378

Fan Connection Table.............................................................................................................................................. 382

Power Supply Table..................................................................................................................................................383

Power Supply Connection Table........................................................................................................................... 386

Temperature Probe Table....................................................................................................................................... 387

Temperature Probe Connection Table..................................................................................................................391

Enclosure Management Module Table.................................................................................................................392

Enclosure Management Module Connection Table.......................................................................................... 396

Battery Table..............................................................................................................................................................397

Battery Connection Table........................................................................................................................................401

Tape Drive Table....................................................................................................................................................... 402

NVME adapter table.................................................................................................................................................404

Logical Devices Group.................................................................................................................................................... 410

Virtual Disk Table....................................................................................................................................................... 410

Virtual Disk Partition..................................................................................................................................................417

Array Disk Logical Connection Table.....................................................................................................................418

Storage Management Event Group............................................................................................................................420

Chapter 4: SNMP Traps.............................................................................................................423

Trap Variables.................................................................................................................................................................. 423

Understanding The Trap Description......................................................................................................................... 425

Understanding Trap Severity....................................................................................................................................... 427

BMC Traps........................................................................................................................................................................427

Chapter 5: Storage Management Alert Reference...................................................................... 431

Alert Monitoring and Logging....................................................................................................................................... 431

Viewing Alerts...................................................................................................................................................................431

Alert Severity Levels....................................................................................................................................................... 431

SNMP Support for Storage Management Alerts.................................................................................................... 432

SNMP Trap Forwarding...........................................................................................................................................432

SNMP Trap Definitions............................................................................................................................................ 432

Trap Variables............................................................................................................................................................ 432

Viewing SNMP Traps..................................................................................................................................................... 435

Alert Descriptions and Corrective Actions................................................................................................................435

Chapter 6: Standard Data Type Definitions................................................................................436

Common Data Types......................................................................................................................................................436

Variables with Data Types of State Capabilities and State Capabilities Unique..............................................436

Dell Status Data Types...................................................................................................................................................437

Dell Date............................................................................................................................................................................438

Full Dates.....................................................................................................................................................................438

Chapter 7: SNMP Sample Output.............................................................................................. 440

Contents 5

1

Introduction

This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information

Base (MIB) which is applicable for Dell EMC OpenManage.

NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms.

This introduction is divided into two sections. The first section,

Introduction to SNMP Reference Guide

, explains the SNMP

Reference Guide design. All essential Simple Network Management Protocol (SNMP) terms are defined in this section. Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time. SNMP experts can skim this section, and beginners can read the section more carefully.

The second section,

Introduction to the Server Administrator SNMP Subagent

, is a more technical introduction to the management information base (MIB) that underlies Server Administrator services.

Topics:

What is new in this release

Supported SNMP Versions

Managed Object Used in This Document

Server Administrator Instrumentation MIB

Server Administrator Baseboard Management Controller, ASF MIB

Server Administrator Storage Management MIB

Server Administrator Field Replaceable Unit MIB

Basic Terminology

Frequently Used Terms in Variable Names

Tables

Section Organization

Other Documents You May Need

Introduction to the Server Administrator SNMP Subagent

System Battery Table

Amperage Probe Table

Power Unit Group

Power Supply Table

Power Usage Table

Voltage Probe Table

System Information Group

What is new in this release

This release of Dell iDRAC , Chassis Management Controller and OpenManage Enterprise-Modular Management Software SNMP introduces the new MIBs:

Added the SNMP v2 MIBs to OM Enterprise - Modular Management Software

Added new traps to iDRAC Traps:

● System Trap Group for Liquid Cooling Traps .

● Storage Trap Group for Software defined subsystem traps .

● Audit Trap Group for User Tracking Trap , Configuration Change Tracking Trap , and Temperature Probe Tracking

Traps .

6 Introduction

Supported SNMP Versions

Table 1. Supported SNMP Versions

Operating System Supported OMSA SNMP version

Windows SNMP v1

Linux SNMP v1

Managed Object Used in This Document

The MIB is divided into several major groups. The following table provides information about the MIB names, name of the agent that uses each MIB and the purpose:

Table 2. Managed Object Used in This Document

MIB Name

10892.mib

dcs3fru.mib

dcstorag.mib

iDRAC-SMIv1.mib

iDRAC-SMIv2.mib

dcs3rmt.mib

rac_host.mib

DELL-RAC-MIB.txt

DcAsfSrv.mib

MX7000-OME-M-v1.mib

MX7000-OME-M-v2.mib

Agent / Hardware Supported

Server Administrator

Server Administrator

Server Administrator Storage

Management iDRAC7 and later

Purpose of the MIB

Provides the information about the systems monitored by Server Administrator instrumentation software.

This is the primary MIB for PowerEdge systems.

Provides the information about the system Field

Replaceable Unit (FRU) to SNMP management applications.

Provides the information about the storage hardware components and RAID configurations monitored by

Server Administrator.

Provides information about the SNMP data and traps supported by iDRAC7 and later. This is the SMIv1 version of the iDRAC MIB.

iDRAC7 and later

Dell Remote Access controller 5 (DRAC

5)

Remote access out-of-band agent

Provides information about the SNMP data and traps supported by iDRAC7 and later. This is the SMIv2 version of the iDRAC MIB.

Provides information about remote access components monitored by the Server Administrator

Remote Access Service.

Provides information about the components monitored by the remote access out-of-band software agent.

Chassis Management Controller (CMC) Provides information about components monitored by the Chassis Management Controller for modular chassis. This MIB is the legacy iDRAC MIB. Changes made in this MIB are not for iDRAC. iDRAC does not support all the objects and traps defined in this MIB.

The new and more extensive iDRAC MIB is available for iDRAC7 and later versions.

Baseboard Management Controller

(BMC)

OpenManage Enterprise-Modular management software (OME-M)

OpenManage Enterprise-Modular management software (OME-M)

Provides information about server Platform Event

Traps generated by the Baseboard Management

Controller.

Provides the information about Dell Remote Access

Controller Out-of-Band MIB for Enterprise-Modular

Management Software. This is the v1 version of the

Modular Management MIB.

Provides the information about Dell Remote Access

Controller Out-of-Band MIB for Enterprise-Modular

Introduction 7

Table 2. Managed Object Used in This Document (continued)

MIB Name Agent / Hardware Supported Purpose of the MIB

Management Software. This is the v2 version of the

Modular Management MIB.

.

For further details see Release Notes for Management Information Base readme_mibs.txt

.

NOTE: You can download the Mibs that are listed from downloads and drivers page at Dell.com/OpenManageManuals .

Server Administrator Instrumentation MIB

The Server Administrator Instrumentation MIB ( filename 10892.mib

) provides instrumentation data that allows you to monitor the health of a system with SNMP management applications. It provides:

● Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at key points in the system

● Rapid access to detailed fault and performance information gathered by industry standard systems management agents

● Version information for Basic Input/Output System (BIOS), firmware, and operating system

● A detailed account of every cost of ownership (COO) detail about your system

In addition, traps are sent to report a change in status of the health of critical components.

The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. The below table describes each Server Administrator Instrumentation MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Instrumentation MIB groups are identified by the SNMP OID

1.3.6.1.4.1.674.10892.1.< MIB group number >, where < MIB group number > is the MIB group number assigned to the MIB group.

See the relevant section for more information about the MIB objects defined in a MIB group.

Table 3. Server Administrator Instrumentation MIB Sections in This Guide

Section Topics

2

3

4

5

6

Instrumentation MIB Version Group — defines version numbers of the

Instrumentation MIB

Systems Management Software Group — defines information about the systems management software and the supported systems management standards

System State Group — defines status, state, and redundancy for a system and its components

Chassis Information Group — defines chassis types, events, and indicators

Operating System Group — defines variables for name, version, service pack, and other information about a system’s operating system

7

8

9

10

11

MIB Group Numbers

1

100

200

300

400

System Resource Group — defines variables for input/output ports, memory, interrupts, and direct memory access

Power Group — defines variables for power units, power supplies, and their current and voltage probes

500

600

Thermal Group — defines variables for temperature probes and cooling devices

700

800 User Security Group — defines variables for creating and modifying user accounts

Remote Flash BIOS Group — defines variables for updating the system’s BIOS remotely

900

8 Introduction

14

15

16

Table 3. Server Administrator Instrumentation MIB Sections in This Guide (continued)

Section

12

13

Topics

Port Group — defines variables for major port types such as keyboard, monitor, small computer system interface (SCSI), Universal Serial Bus

(USB), and parallel and serial ports

Device Group — defines variables for pointing, keyboard, processor, cache, memory, and personal computer interface devices

MIB Group Numbers

1000

1100

17

18

20

21

26

Slot Group — defines variables for the system’s slots 1200

Memory Group — defines variables for the system’s physical memory 1300

1400 BIOS Setup Control Group — defines variables for BIOS functions such as boot sequence, speakers, Wake on the local area network

(LAN), diskettes, ports, and network interface controllers (NIC)

Local Response Agent Group — defines variables for global settings and actions. These variables allow users to predetermine how the system responds to a particular type of event

1500

1600 Cost of Ownership Group — defines variables for tracking data on the system’s service contract, lease, repair records, trouble tickets, and so on

Cluster Group — defines variables for systems that operate as a cluster

Baseboard Management Controller Group — provides information about the Baseboard Management Controller (BMC) that may be present in your system. In addition to providing general information about the BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC

Traps — defines the types of alerts that can be sent to report the status of critical components

1800

1900

5000

Server Administrator Baseboard Management

Controller, ASF MIB

The Server Administrator BMC MIB (filename DcAsfSrv.mib

) provides information about the traps sent by BMC. The Server

Administrator BMC MIB structures its MIB objects that provide related information. The BMC MIB groups are identified by the

SNMP OID 1.3.6.1.4.1.3183.1.1.< MIB group number >. The BMC MIB adheres to ASF 2.0 standard and hence the enterprise ID is wired for management (3183).

Server Administrator Storage Management MIB

The Server Administrator Storage Management MIB (filename dcstorag.mib

) provides storage management data that allows you to monitor the health of storage resources with SNMP management applications.

The following table describes each Server Administrator Storage Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Storage Management MIB groups are identified by the SNMP OID

1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.

Table 4. Server Administrator Storage Management MIB Sections in This Guide

Section

23

Topics

Storage Management Group — consists of definitions for the following

MIB groups:

● Storage Management Group

MIB Group Numbers

10893

NA

Introduction 9

Table 4. Server Administrator Storage Management MIB Sections in This Guide (continued)

Section Topics

● Storage Management Information Group

● Global Data Group

● Physical Devices Group

● Logical Devices Group

● Storage Management Event Group

● Software Group

MIB Group Numbers

20

NA

NA

130

140

NA

1

27 Storage Management Alert Reference — lets you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks

NA

Server Administrator Field Replaceable Unit MIB

The Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib

) provides information about field replaceable unit

(FRU) hardware that may be present in your system.

The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. The following table describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.< MIB group number > where < MIB group number > is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.

Table 5. Server Administrator Field Replaceable Unit MIB Sections in This Guide

Section

22

Topic

Field Replaceable Unit Group — provides information about field replaceable units that may be present in your system

MIB Group Numbers

2000

Basic Terminology

It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the

Glossary available on the Dell Support website at dell.com/support/manuals .

Frequently Used Terms in Variable Names

The following terms are frequently used in the name of a MIB variable:

Capability refers to the actions an object can perform, or to actions that can be taken by the object. Hot-pluggable is an example of a capability. If a card is hot-pluggable, it can be replaced while a system is running. Capability settings refer to the capabilities of the object that the user can select from and activate if desired. Capability settings allow users of the server administrator to predetermine how an object behaves under specific conditions.

Settings are the conditions of a manageable object that determine what happens when a certain value is detected in a component. For example, a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius. If the probe reaches that temperature, the setting causes an alert to be sent to the management console. Some settings, when reached, can trigger a system shutdown or other response to prevent damage to the system.

State refers to the condition of an object that has more than one condition. For example, an object may be in a not ready or in an enabled state.

10 Introduction

Status refers to the health of an object or how the object is functioning. For example, the status of a temperature probe that is measuring acceptable temperatures would be reported as normal. When the probe begins reading temperatures that exceed limits set by the user, it reports a critical status.

Tables

This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables.

SNMP Tables

Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays. In SNMP, objects that have a relationship to other objects are called columnar objects.

Columnar objects are objects used to form lists and tables. When a MIB group is divided into one or more discrete tables, the word table has a technical meaning. An example is the section of this reference guide entitled Universal Unique Identifier

(UUID). The UUID object has a type and a value that uniquely identifies an object such as a chassis. The table defines all of the variables that comprise the managed object UUID.

The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index, UUID Type, and UUID Value.

These objects comprise the Server Administrator definitions for the UUID.

Table 6. UUID Table

Name

Object ID

Description

Syntax

Access uUIDTable

1.3.6.1.4.1.674.10892.1.300.20

Defines the UUID table.

SEQUENCE OF UUIDTableEntry

Not accessible

Table 7. UUID Table Entry

Name

Object ID

Description

Syntax

Access

Index uUIDTableEntry

1.3.6.1.4.1.674.10892.1.300.20.1

Defines the UUID table entry.

UUIDTableEntry

Not accessible uUIDIndex

, uUIDchassisIndex

Table 8. UUID Chassis Index

Name

Object ID

Description

Syntax

Access uUIDchassisIndex

1.3.6.1.4.1.674.10892.1.300.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Introduction 11

Table 9. UUID Index

Name

Object ID

Description

Syntax

Access

Table 10. UUID Type

Name

Object ID

Description

Syntax

Access

Table 11. UUID Value

Name

Object ID

Description

Syntax

Access Read-only uUIDIndex

1.3.6.1.4.1.674.10892.1.300.20.1.2

Defines the index of the UUID in a specified chassis.

DellObjectRange

Read-only uUIDType

1.3.6.1.4.1.674.10892.1.300.20.1.3

Defines the type of the UUID for this chassis.

DellUUIDType

Read-only uUIDValue

1.3.6.1.4.1.674.10892.1.300.20.1.4

Defines the value of the UUID for this chassis.

Octet String (SIZE[16])

Read-only

Section Organization

Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables. The third section documents the variables that comprise the group, and if applicable, the variables that comprise the tables. The fourth section contains definitions for any Server

Administrator-specific variables that are used in the section. The following example shows the typical content of these four sections:

1. BIOS Setup Control Group — This section explains the purpose of the MIB group and summarizes the major features of the component groups.

2. BIOS Group Tables — If there is more than one SNMP table for a group, this section lists all of the tables. For this BIOS group example, there are eight tables listed. In each section, double-clicking any table on the list takes you to that table.

● BIOS Setup Control Table

● SCSI Control Table

● Parallel Port Control Table

● Serial Port Control Table

● USB Control Table

● IDE Control Table

● Diskette Control Table

● Network Interface Control Table

3. Variables that make up each table in the group — This section documents the variables for the eight tables that comprise the BIOS group.

4. BIOS Variable Values — This section explains any Server Administrator-specific variables and data types that are used in this section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable meanings. Information on each Server Administrator-specific variable is presented in a formatted table.

12 Introduction

Other Documents You May Need

In addition to this guide, you can access the following guides available at dell.com/softwaresecuritymanuals .

● The Dell EMC Systems Software Support Matrix provides information about the various systems, the operating systems supported by these systems, and the components that can be installed on these systems.

● The Dell EMC OpenManage Server Administrator Installation Guide contains instructions to help you install Dell EMC

OpenManage Server Administrator.

● The Dell EMC OpenManage Management Station Software Installation Guide contains instructions to help you install Dell

EMC OpenManage management station software.

● The Dell EMC OpenManage SNMP Reference Guide documents the Simple Network Management Protocol (SNMP) management information base (MIB).

● The Dell EMC OpenManage Server Administrator CIM Reference Guide documents the Common Information Model (CIM) provider, an extension of the standard management object format (MOF) file.

● The Dell EMC Messages Reference Guide lists the messages that are displayed in your Server Administrator home page Alert log or on your operating system’s event viewer.

● The Dell EMC OpenManage Server Administrator Command Line Interface Guide documents the complete command line interface for Server Administrator.

● The Dell Remote Access Controller User's Guide provides comprehensive information about using the RACADM command line utility to configure a DRAC.

● The Dell Chassis Management Controller User’s Guide provides comprehensive information about using the controller that manages all modules in the chassis containing your system.

● The Command Line Reference Guide for iDRAC 6 and CMC provides information about the RACADM subcommands, supported interfaces, property database groups and object definitions for iDRAC6 and CMC.

● The Integrated Dell Remote Access Controller 7 (iDRAC7) User's Guide provides information about configuring and using iDRAC7 for 12G rack, tower, and blade servers to remotely manage and monitor your system and its shared resources through a network.

● The Integrated Dell Remote Access Controller 6 (iDRAC6) Enterprise for Blade Servers User Guide provides information about configuring and using an iDRAC6 for 11G blade servers to remotely manage and monitor your system and its shared resources through a network.

● The Integrated Dell Remote Access Controller 6 (iDRAC6) User Guide provides complete information about configuring and using an iDRAC6 for 11G tower and rack servers to remotely manage and monitor your system and its shared resources through a network.

● The Dell Online Diagnostics User's Guide provides complete information on installing and using Online Diagnostics on your system.

● The Dell OpenManage Baseboard Management Controller Utilities User's Guide provides additional information about using

Server Administrator to configure and manage your system's BMC.

● The Dell EMC OpenManage Server Administrator Storage Management User's Guide is a comprehensive reference guide for configuring and managing local and remote storage attached to a system.

● The Dell Remote Access Controller Racadm User's Guide provides information about using the racadm command line utility.

● The Dell Remote Access Controller User’s Guide provides complete information about installing and configuring a DRAC controller and using DRAC to remotely access an inoperable system.

● The Dell Update Packages User's Guide provides information about obtaining and using Dell Update Packages as part of your system update strategy.

● The Dell EMC OpenManage Server Update Utility User's Guide provides information about obtaining and using the Server

Update Utility (SUU) to update your systems or to view the updates available for any systems listed in the Repository.

● The Dell Management Console User’s Guide provides information about installing, configuring, and using Dell Management

Console.

● The Dell Lifecycle Controller User's Guide provides information on setting up and using the Unified Server Configurator to perform systems and storage management tasks throughout your system’s lifecycle.

● The Dell License Manager User’s Guide provides information about managing component server licenses for the 12G servers.

● The Glossary for information on terms used in this document.

Accessing support content from the Dell EMC support site

Access supporting content related to an array of systems management tools using direct links, going to the Dell EMC support site, or using a search engine.

● Direct links:

Introduction 13

○ For Dell EMC Enterprise Systems Management and Dell EMC Remote Enterprise Systems Management— https:// www.dell.com/esmmanuals

○ For Dell EMC Virtualization Solutions— www.dell.com/virtualizationsolutions

○ For Dell EMC OpenManage— https://www.dell.com/openmanagemanuals

○ For iDRAC— https://www.dell.com/idracmanuals

○ For Dell EMC OpenManage Connections Enterprise Systems Management— https://www.dell.com/

OMConnectionsEnterpriseSystemsManagement

○ For Dell EMC Serviceability Tools— https://www.dell.com/serviceabilitytools

● Dell EMC support site:

1. Go to https://www.dell.com/support .

2. Click Browse all products .

3. From the All products page, click Software , and then click the required link.

4. Click the required product and then click the required version.

Using search engines, type the name and version of the document in the search box.

Introduction to the Server Administrator SNMP

Subagent

This guide provides formatted information drawn primarily from the MIB files written for the Server Administrator services that support the SNMP protocol.

For each of the variables defined in the MIBs, the following fields are specified:

● Variable name

● OID or unique identifying number

● Description

● Data type of the variable (for example: integer, string, octet string)

● Whether the variable is accessible, not accessible, or read-only

● Index or indexes, if applicable

For each MIB group that has unique variable definitions, tables are included in the last section of the section to explain the meaning of the terms.

Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of Management Information

(SMI) is a standard that specifies the rules for defining the structure and type of managed objects and events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155. The Server Administrator MIB conforms to the SMIv1 standard.

SNMP is a systems management standard originally designed for network management. SNMP manages much more than networks. Information Technology (IT) professionals use SNMP for monitoring and managing computer systems and the various components and peripherals supported by their systems.

SNMP standards are defined by the Internet Engineering Task Force (IETF). SNMP version 1 was published in August 1988 and is the most commonly supported version of SNMP. SNMP version 2 was first published in May 1993, but has not gained widespread market acceptance. SNMP version 3 was recently completed and has addressed security issues that exist in version

1.

All SNMP systems consist of one or more managed systems that provide data through an SNMP agent to a management system. The management system provides a user interface to view data from the managed systems. The management system and managed systems communicate over a network (typically through User Datagram Protocol/Internet Protocol [UDP/IP]).

The management system and a managed system communicate by means of a common data schema. SNMP MIB files define the structure, type, and values of the SNMP data. While MIBs can be standardized or enterprise specific, most operating systems supply SNMP agents for the standard MIB-I and MIB-II schemas. MIB-I defines a base set of standard management information for systems implementing the Internet Protocol (IP) suite. MIB-II defines characteristics of the system, characteristics of network interfaces, and characteristics of components of the IP on the system. In addition to the standard MIBs, many hardware vendors have defined MIBs that provide management data specific to their systems and peripheral devices.

Monitored data can be retrieved through SNMP using the Get command. Typically, this command requires the host name or

IP address of the target machine as well as the OID of the data to retrieve. Exact details are dependent on the operating system and the development tools being used to create the management application. The Get command has a variant known as

GetNext.

14 Introduction

Management Information Base Object Identifiers

Each data class within a Management Information Base (MIB) is defined by an Object Identifier (OID). OIDs are unique across all MIBs. An OID consists of a series of digits separated by periods. The OID functions in a similar fashion to a phone number.

The phone number 011-512-471-0000 uniquely identifies a single phone. The phone number can be broken down into a number of components to uniquely identify a phone. The first component, 011, is the country code for the United States. The second component, 512, identifies the area code for central Texas. The third component, 471, is the phone exchange for a large state university in the city of Austin. The final component, 0000, is the main switchboard.

There are two main differences between the phone number example and an actual OID. The first difference is that there are many more components in an OID, up to 128. The combination of these components is called an OID prefix. The second difference is that OIDs support the concept of indexes or keys. The OID prefix specifies the data class but does not specify an instance of the data within the class. Indexes can be used to identify the instances of a data class. These indexes are referred to as the OID suffix.

The assignment of values for each OID prefix component can be illustrated by using a tree structure. The following is an example of an OID assignment:

Table 12. ROOT

CCITT(0)

ISO(1)

ORG(3)

DOD(6)

INTERNET(1)

MGMT(2)

MIB(1)

EXPERIMENTAL

(3)

PRIVATE(4)

ENTERPRISES(1

)

DELL (674)

SNMPv2(6)

In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674.

The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administratordefined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values.

SNMP Security

SNMP version 1 has a very limited security mechanism. SNMP agents support the use of a community string, which is configured at each SNMP agent and is passed as a part of all SNMP request messages. There is no verification that the requester is actually a member of the specified community. As most system and network management data is not confidential, this limited security is acceptable for Get types of requests. On the other hand, this security is not acceptable for Set types of operations where an SNMP request could power off a system, reconfigure a redundant array of independent disks (RAID) card, and so on. Dell has chosen not to support SNMP Set operations for this reason.

NOTE: The default SNMP agent configuration usually includes a SNMP community name such as public. For security reasons, change the SNMP community names from their default values. For information about changing SNMP community names, see the Dell OpenManage Server Administrator User’s Guide available on the Dell Support website at dell.com/ openmanagemanuals .

NOTE: As of iDRAC7 firmware release r1.30.30, iDRAC7 supports SNMP query operations (GET, GETNEXT, GETBULK) via the SNMPv3 protocol, in addition to supporting query operations via the SNMP v1 and SNMP v2c protocols. More specifically, iDRAC7 now supports the SNMP User Security Model (USM).

Introduction 15

SNMP Traps

SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures.

Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion. SNMP traps avoid these limitations of the polling method.

An SNMP trap is an asynchronous event indicating that something significant has occurred. This is analogous to a pager receiving an important message, except that the SNMP trap frequently contains all the information needed to diagnose a fault.

Two drawbacks to SNMP traps are that they are sent using UDP, which is not a guaranteed delivery mechanism, and that they are not acknowledged by the receiver.

An SNMP trap message contains the trap’s enterprise OID, the agent IP address, a generic trap ID, the specific trap ID, a time stamp, and zero or more variable bindings (varbinds). The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator-defined trap. A varbind consists of an OID and its value and provides additional information about the trap.

In order for a management system to receive SNMP traps from a managed system, the node must be configured to send traps to the management system. Trap destination configuration depends on the operating system. When this configuration is done, a management application on the management system can wait for traps and act on them when received.

NOTE: For information on Server Administrator Storage Management traps, see in Storage Management Alert Reference,

the Alert Descriptions and Corrective Actions

.

NOTE: For the list of storage management alerts and storage management messages, see the Dell OpenManage Server

Administrator Messages Reference Guide available on the Dell Support site at dell.com/openmanagemanuals navigate to

OpenManage Software and select the version required.

System Battery Table

The System Battery Table objects provide information about the system battery in which the iDRAC resides.

Table 13. System Battery Table Entry

Name

Object ID

Description

Syntax

Access systemBatteryTableEntry

1.3.6.1.4.1.674.10892.5.4.600.50.1.1

This object defines the System Battery Table Entry.

StringType

Read-only

Table 14. System Battery Index

Name

Object ID

Description

Syntax

Access systemBatteryIndex

1.3.6.1.4.1.674.10892.5.4.600.50.1.2

This attribute defines the index (one based) of the battery.

ObjectRange

Read-only

Table 15. System Battery State Capabilities

Name

Object ID

Description

Syntax systemBatteryStateCapabilities

1.3.6.1.4.1.674.10892.5.4.600.50.1.3

This attribute defines the state capabilities of the battery.

StateCapabilitiesFlags

16 Introduction

Table 15. System Battery State Capabilities (continued)

Access Read-only

Table 16. System Battery State Settings

Name

Object ID

Description .

Syntax

Access systemBatteryStateSettings

1.3.6.1.4.1.674.10892.5.4.600.50.1.4

This attribute defines the state settings of the battery.

StateSettingsFlags

Read-only

Table 17. System Battery Status

Name

Object ID

Description

Syntax

Access systemBatteryStatus

1.3.6.1.4.1.674.10892.5.4.600.50.1.5

This attribute defines the status of the battery.

ObjectStatusEnum

Read-only

Table 18. System Battery Reading

Name systemBatteryReading

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.5.4.600.50.1.6

This attribute defines the reading of the battery.

SystemBatteryReadingFlags

Read-only

Table 19. System Battery Location Name

Name

Object ID

Description

Syntax

Access systemBatteryLocationName

1.3.6.1.4.1.674.10892.5.4.600.50.1.7

This attribute defines the location of the battery.

String64

Read-only

Amperage Probe Table

The amperage probe objects provide information about the system amperage probe in which the iDRAC resides.

Table 20. Amperage Probe Chassis Index

Name amperageProbechassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.5.4.600.30.1.1

This attribute defines the index (one based) of the system chassis.

ObjectRange

Read-only

Introduction 17

Table 21. Amperage Probe Index

Name

Object ID

Description

Syntax

Access amperageProbeIndex

1.3.6.1.4.1.674.10892.5.4.600.30.1.2

This attribute defines the index (one based) of the amperage probe.

ObjectRange

Read-only

Table 22. Amperage Probe State Capabilities

Name

Object ID

Description

Syntax

Access amperageProbeStateCapabilities

1.3.6.1.4.1.674.10892.5.4.600.30.1.3

This attribute defines the state capabilities of the amperage probe.

StateCapabilitiesFlags

Read-only

Table 23. Amperage Probe State Settings

Name

Object ID

Description .

Syntax

Access amperageProbeStateSettings

1.3.6.1.4.1.674.10892.5.4.600.30.1.4

This attribute defines the state settings of the amperage probe.

StateSettingsFlags

Read-only

Table 24. Amperage Probe Status

Name

Object ID

Description

Syntax

Access amperageProbeStatus

1.3.6.1.4.1.674.10892.5.4.600.30.1.5

This attribute defines the probe status of the amperage probe.

StatusProbeEnum

Read-only

Table 25. Amperage Probe Reading

Name

Object ID

Description

Syntax

Access amperageProbeReading

1.3.6.1.4.1.674.10892.5.4.600.30.1.6

This attribute defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete. When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps, the value returned for this attribute is the power usage that the probe is reading in tenths of Amps. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, a value is not returned for this attribute.

Signed32BitRange

Read-only

Table 26. Amperage Probe Type

Name

Object ID

Description amperageProbeType

1.3.6.1.4.1.674.10892.5.4.600.30.1.7

This attribute defines the type of the amperage probe.

18 Introduction

Table 26. Amperage Probe Type (continued)

Syntax

Access

AmperageProbeTypeEnum

Read-only

Table 27. Amperage Probe Location Name

Name

Object ID

Description

Syntax

Access amperageProbeLocationName

1.3.6.1.4.1.674.10892.5.4.600.30.1.8

This attribute defines the location of the amperage probe.

String64

Read-only

Table 28. Amperage Probe Upper Non Recoverable Threshold

Name

Object ID

Description

Syntax

Access amperageProbeUpperNonRecoverableThreshold

1.3.6.1.4.1.674.10892.5.4.600.30.1.9

This attribute defines the upper non recoverable threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.

Signed32BitRange

Read-only

Table 29. Amperage Probe Upper Critical Threshold

Name

Object ID

Description

Syntax

Access amperageProbeUpperCriticalThreshold

1.3.6.1.4.1.674.10892.5.4.600.30.1.10

This attribute defines the upper critical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.

Signed32BitRange

Read-only

Table 30. Amperage Probe Upper NonCritical Threshold

Name

Object ID

Description

Syntax

Access amperageProbeUpperNonCriticalThreshold

1.3.6.1.4.1.674.10892.5.4.600.30.1.11

This attribute defines the upper noncritical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.

Signed32BitRange

Read-only

Table 31. Amperage Probe Lower NonCritical Threshold

Name

Object ID

Description

Syntax

Access amperageProbeLowerNonCriticalThreshold

1.3.6.1.4.1.674.10892.5.4.600.30.1.12

This attribute defines the lower noncritical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.

Signed32BitRange

Read-only

Introduction 19

Table 32. Amperage Probe Lower Critical Threshold

Name

Object ID

Description

Syntax

Access amperageProbeLowerCriticalThreshold

1.3.6.1.4.1.674.10892.5.4.600.30.1.13

This attribute defines the lower critical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.

Signed32BitRange

Read-only

Table 33. Amperage Probe Lower NonRecoverable Threshold

Name

Object ID

Description

Syntax

Access amperageProbeLowerNonRecoverableThreshold

1.3.6.1.4.1.674.10892.5.4.600.20.1.14

This attribute defines the lower non recoverable threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.

Signed32BitRange

Read-only

Table 34. Amperage Probe Probe Capabilities

Name

Object ID

Description

Syntax

Access amperageProbeProbeCapabilities

1.3.6.1.4.1.674.10892.5.4.600.20.1.15

This attribute defines the probe capabilities of the amperage probe.

ProbeCapabilitiesFlags

Read-only

Table 35. Amperage Probe Discrete Reading

Name

Object ID

Description

Syntax

Access amperageProbeDiscreteReading

1.3.6.1.4.1.674.10892.5.4.600.20.1.16

This attribute defines the reading for an amperage probe of type amperageProbeTypeIsDiscrete. When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.

AmperageDiscreteReadingEnum

Read-only

Power Unit Group

The Power Group objects provide information about the system power unit in which the iDRAC resides.

Table 36. Power Unit Chassis Index

Name

Object ID

Description

Syntax

Access powerUnitchassisIndex

1.3.6.1.4.1.674.10892.5.4.600.10.1.1

This attribute defines the index (one based) of the system chassis.

ObjectRange

Read-only

20 Introduction

Table 37. Power Unit Index

Name

Object ID

Description

Syntax

Access powerUnitIndex

1.3.6.1.4.1.674.10892.5.4.600.10.1.1.2

This attribute defines the index (one based) of the power unit.

ObjectRange

Read-only

Table 38. Power Unit State Capabilities

Name

Object ID

Description

Syntax

Access powerUnitStateCapabilities

1.3.6.1.4.1.674.10892.5.4.600.10.1.1.3

This attribute defines the state capabilities of the power unit.

StateCapabilitiesFlags

Read-only

Table 39. Power Unit State Settings

Name

Object ID

Description .

Syntax

Access powerUnitStateSettings

1.3.6.1.4.1.674.10892.5.4.600.10.1.1.4

This attribute defines the state settings of the power unit.

StateSettingsFlags

Read-only

Table 40. Power Unit Redundancy Status

Name

Object ID

Description

Syntax

Access powerUnitRedundancyStatus

1.3.6.1.4.1.674.10892.5.4.600.10.1.1.5

This attribute defines the redundancy status of the power unit.

StatusRedundancyEnum

Read-only

Table 41. Power Supply Count For Redundancy

Name

Object ID

Description

Syntax

Access powerSupplyCountForRedundancy

1.3.6.1.4.1.674.10892.5.4.600.10.1.1.6

This attribute defines the total number of power supplies required for this power unit to have full redundancy.

ObjectRange

Read-only

Table 42. Power Unit Name

Name

Object ID

Description

Syntax

Access powerUnitName

1.3.6.1.4.1.674.10892.5.4.600.10.1.1.7

This attribute defines the name of the power unit.

String64

Read-only

Introduction 21

Table 43. Power Unit Status

Name

Object ID

Description

Syntax

Access powerUnitStatus

1.3.6.1.4.1.674.10892.5.4.600.10.1.1.8

This attribute defines the status of the power unit.

ObjectStatusEnum

Read-only

Power Supply Table

The Power Supply objects provide information about the system power supply in which the iDRAC resides.

Table 44. Power Supply Chassis Index

Name

Object ID

Description

Syntax

Access powerSupplychassisIndex

1.3.6.1.4.1.674.10892.5.4.600.12.1.1

This attribute defines the index (one based) of the system chassis.

PowerSupplyTableEntry

Read-only

Table 45. Power Supply Index

Name

Object ID

Description

Syntax

Access powerSupplyIndex

1.3.6.1.4.1.674.10892.5.4.600.12.1.2

This attribute defines the index (one based) of the power supply.

ObjectRange

Read-only

Table 46. Power Supply State Capabilities Unique

Name

Object ID

Description

Syntax

Access powerSupplyStateCapabilitiesUnique

1.3.6.1.4.1.674.10892.5.4.600.12.1.3

This attribute defines the state capabilities of the power unit.

StateCapabilitiesFlags

Read-only

Table 47. Power Supply State Settings Unique

Name

Object ID

Description .

Syntax

Access powerSupplyStateSettingsUnique

1.3.6.1.4.1.674.10892.5.4.600.12.1.4

This attribute defines the state settings of the power supply.

PowerSupplyStateSettingsUniqueFlags

Read-only

Table 48. Power Supply Status

Name

Object ID

Description powerSupplyStatus

1.3.6.1.4.1.674.10892.5.4.600.12.1.5

This attribute defines the status of the power supply.

22 Introduction

Table 48. Power Supply Status (continued)

Syntax

Access

ObjectStatusEnum

Read-only

Table 49. Power Supply Output Watts

Name

Object ID

Description

Syntax

Access powerSupplyOutputWatts

1.3.6.1.4.1.674.10892.5.4.600.12.1.6

This attribute defines the maximum sustained output wattage of the power supply (in tenths of Watts).

Signed32BitRange

Read-only

Table 50. Power Supply Type

Name

Object ID

Description

Syntax

Access powerSupplyType

1.3.6.1.4.1.674.10892.5.4.600.12.1.7

This attribute defines the type of the power supply.

String64

Read-only

Table 51. Power Supply Location Name

Name

Object ID

Description

Syntax

Access powerSupplyLocationName

1.3.6.1.4.1.674.10892.5.4.600.12.1.8

This attribute defines the location of the power supply.

String64

Read-only

Table 52. Power Supply Maximum Input Voltage

Name

Object ID

Description

Syntax

Access powerSupplyMaximumInputVoltage

1.3.6.1.4.1.674.10892.5.4.600.12.1.9

This attribute defines the maximum input voltage of the power supply (in Volts).

Signed32BitRange

Read-only

Table 53. Power Supply power Unit Index Reference

Name

Object ID

Description

Syntax

Access powerSupplypowerUnitIndexReference

1.3.6.1.4.1.674.10892.5.4.600.12 .1.10

This attribute defines the index to the associated power unit if the power supply is part of a power unit.

ObjectRange

Read-only

Table 54. Power Supply Sensor State

Name powerSupplySensorState

Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .1.11

Introduction 23

Table 54. Power Supply Sensor State (continued)

Description

Syntax

Access

This attribute defines the state reported by the power supply sensor. This attribute supplements the attribute powerSupplyStateSettingsUnique.

PowerSupplySensorStateFlags

Read-only

Table 55. Power Supply Configuration Error Type

Name

Object ID

Description

Syntax

Access powerSupplyConfigurationErrorType

1.3.6.1.4.1.674.10892.5.4.600.12 .1.12

This attribute defines the type of configuration error reported by the power supply sensor. When the configurationError bit is on in the value for the attribute powerSupplySensorState, a value is returned for this attribute; otherwise, a value is not returned for this attribute.

PowerSupplyConfigurationErrorTypeEnum

Read-only

Table 56. Power Supply Power Monitor Capable

Name

Object ID

Description

Syntax

Access powerSupplyPowerMonitorCapable

1.3.6.1.4.1.674.10892.5.4.600.12 .1.13

This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption.

BooleanType

Read-only

Table 57. Power Supply Rated Input Wattage

Name

Object ID

Description

Syntax

Access powerSupplyRatedInputWattage

1.3.6.1.4.1.674.10892.5.4.600.12 .1.14

This attribute defines the rated input wattage of the power supply (in tenths of Watts).

Signed32BitRange

Read-only

Table 58. Power Supply FQDD

Name

Object ID

Description

Syntax

Access powerSupplyFQDD

1.3.6.1.4.1.674.10892.5.4.600.12 .1.15

Fully qualified device descriptor (FQDD) of the power supply.

FQDDString

Read-only

Table 59. Power Supply Current Input Voltage

Name

Object ID

Description

Syntax

Access powerSupplyCurrentInputVoltage

1.3.6.1.4.1.674.10892.5.4.600.12 .1.16

This attribute defines the current input voltage to the power supply (in Volts).

PowerSupplyConfigurationErrorTypeEnum

Read-only

24 Introduction

Power Usage Table

The Power usage objects provide information about the power usage in which the iDRAC resides.

Table 60. Power Usage Chassis Index

Name

Object ID

Description

Syntax

Access powerUsageChassisIndex

1.3.6.1.4.1.674.10892.5.4.600.60.1.1

This attribute defines the index (one based) of the associated system chassis.

ObjectRange

Read-only

Table 61. Power Usage Index

Name

Object ID

Description

Syntax

Access powerUsageIndex

1.3.6.1.4.1.674.10892.5.4.600.60.1.2

This attribute defines the index (one based) of the power usage information.

ObjectRange

Read-only

Table 62. Power Usage State Capabilities

Name

Object ID

Description

Syntax

Access powerUsageStateCapabilities

1.3.6.1.4.1.674.10892.5.4.600.60.1.3

This attribute defines the state capabilities of the power usage information.

StateCapabilitiesFlags

Read-only

Table 63. Power Usage State Settings

Name

Object ID

Description .

Syntax

Access powerUsageStateSettings

1.3.6.1.4.1.674.10892.5.4.600.60.1.4

This attribute defines the state settings of the power usage information.

StateSettingsFlags

Read-only

Table 64. Power Usage Status

Name

Object ID

Description

Syntax

Access powerUsageStatus

1.3.6.1.4.1.674.10892.5.4.600.60.1.5

This attribute defines the status of the power usage information.

ObjectStatusEnum

Read-only

Table 65. Power Usage Entity Name

Name

Object ID powerUsageEntityName

1.3.6.1.4.1.674.10892.5.4.600.60.1.6

Introduction 25

Table 65. Power Usage Entity Name (continued)

Description

Syntax

Access

This attribute defines the name of the entity associated with this power usage information.

String64

Read-only

Table 66. Power Usage Cumulative Wattage

Name

Object ID

Description

Syntax

Access powerUsageCumulativeWattage

1.3.6.1.4.1.674.10892.5.4.600.60.1.7

This attribute defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute.

Unsigned32BitRange

Read-only

Table 67. Power Usage Cumulative Wattage Start Date Name

Name

Object ID

Description

Syntax

Access powerUsageCumulativeWattageStartDateName

1.3.6.1.4.1.674.10892.5.4.600.60.1.8

This attribute defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage attribute.

DateName

Read-only

Table 68. Power Usage Peak Watts

Name

Object ID

Description

Syntax

Access powerUsagePeakWatts

1.3.6.1.4.1.674.10892.5.4.600.60.1.9

This attribute defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute.

Unsigned32BitRange

Read-only

Table 69. Power Usage Peak Watts Start Date Name

Name

Object ID

Description

Syntax

Access powerUsagePeakWattsStartDateName

1.3.6.1.4.1.674.10892.5.4.600.60.1.10

This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute.

DateName

Read-only

Table 70. Power Usage Peak Watts Reading Date Name

Name

Object ID

Description

Syntax powerUsagePeakWattsReadingDateName

1.3.6.1.4.1.674.10892.5.4.600.60.1.11

This attribute defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured.

DateName

26 Introduction

Table 70. Power Usage Peak Watts Reading Date Name (continued)

Access Read-only

Table 71. Power Usage Peak Amps

Name

Object ID

Description

Syntax

Access powerUsagePeakAmps

1.3.6.1.4.1.674.10892.5.4.600.60.1.12

This attribute defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute.

Unsigned32BitRange

Read-only

Table 72. Power Usage Peak Amps Start Date Name

Name

Object ID

Description

Syntax

Access powerUsagePeakAmpsStartDateName

1.3.6.1.4.1.674.10892.5.4.600.60.1.13

This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute.

DateName

Read-only

Table 73. Power Usage Peak Amps Reading Date Name

Name

Object ID

Description

Syntax

Access powerUsagePeakAmpsReadingDateName

1.3.6.1.4.1.674.10892.5.4.600.60.1.14

This attribute defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured.

DateName

Read-only

Table 74. Power Usage Idle Power

Name

Object ID

Description

Syntax

Access powerUsageIdlePower

1.3.6.1.4.1.674.10892.5.4.600.60.1.15

This attribute defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration.

Unsigned32BitRange

Read-only

Table 75. Power Usage Max Potential Power

Name

Object ID

Description

Syntax

Access powerUsageMaxPotentialPower

1.3.6.1.4.1.674.10892.5.4.600.60.1.16

This attribute defines the system maximum potential power (in Watts). This is the maximum power the system can consume based on the current hardware configuration.

Unsigned32BitRange

Read-only

Introduction 27

Table 76. Power Usage Power Cap Capabilities

Name

Object ID

Description

Syntax

Access powerUsagePowerCapCapabilities

1.3.6.1.4.1.674.10892.5.4.600.60.1.17

This attribute defines the system power cap capabilities.

PowerCapCapabilitiesFlags

Read-only

Table 77. Power Usage Power Cap Setting

Name

Object ID

Description

Syntax

Access powerUsagePowerCapSetting

1.3.6.1.4.1.674.10892.5.4.600.60.1.18

This attribute defines the system power cap setting.

PowerCapSettingEnum

Read-only

Table 78. Power Usage Power Cap Value

Name

Object ID

Description

Syntax

Access powerUsagePowerCapValue

1.3.6.1.4.1.674.10892.5.4.600.60.1.19

This attribute defines the system power cap value (in Watts).

Unsigned32BitRange

Read-only

Table 79. Power Usage Instantaneous Headroom

Name

Object ID

Description

Syntax

Access powerUsageInstantaneousHeadroom

1.3.6.1.4.1.674.10892.5.4.600.60.1.20

This attribute defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw.

Unsigned32BitRange

Read-only

Table 80. Power Usage Peak Headroom

Name

Object ID

Description

Syntax

Access powerUsagePeakHeadroom

1.3.6.1.4.1.674.10892.5.4.600.60.1.21

This attribute defines the system peak headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus peak power draw.

Unsigned32BitRange

Read-only

Voltage Probe Table

The voltage probe objects provide information about the system voltage probe in which the iDRAC resides.

Table 81. Voltage Probe Chassis Index

Name voltageProbechassisIndex

28 Introduction

Table 81. Voltage Probe Chassis Index (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.5.4.600.20.1.1

This attribute defines the index (one based) of the system chassis.

ObjectRange

Read-only

Table 82. Voltage Probe Index

Name

Object ID

Description

Syntax

Access voltageProbeIndex

1.3.6.1.4.1.674.10892.5.4.600.20.1.2

This attribute defines the index (one based) of the voltage probe.

ObjectRange

Read-only

Table 83. Voltage Probe State Capabilities

Name

Object ID

Description

Syntax

Access voltageProbeStateCapabilities

1.3.6.1.4.1.674.10892.5.4.600.20.1.3

This attribute defines the state capabilities of the voltage probe.

StateCapabilitiesFlags

Read-only

Table 84. Voltage Probe State Settings

Name

Object ID

Description .

Syntax

Access voltageProbeStateSettings

1.3.6.1.4.1.674.10892.5.4.600.20.1.4

This attribute defines the state settings of the voltage probe.

StatusProbeEnum

Read-only

Table 85. Voltage Probe Status

Name

Object ID

Description

Syntax

Access voltageProbeStatus

1.3.6.1.4.1.674.10892.5.4.600.20.1.5

This attribute defines the probe status of the voltage probe.

StatusProbeEnum

Read-only

Table 86. Voltage Probe Reading

Name

Object ID

Description

Syntax

Access voltageProbeReading

1.3.6.1.4.1.674.10892.5.4.600.20.1.6

This attribute defines the reading for a voltage probe of type other than voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, the value returned for this attribute is the voltage that the probe is reading in millivolts. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute.

Signed32BitRange

Read-only

Introduction 29

Table 87. Voltage Probe Type

Name

Object ID

Description

Syntax

Access voltageProbeType

1.3.6.1.4.1.674.10892.5.4.600.20.1.7

This attribute defines the type of the voltage probe.

VoltageTypeEnum

Read-only

Table 88. Voltage Probe Location Name

Name

Object ID

Description

Syntax

Access voltageProbeLocationName

1.3.6.1.4.1.674.10892.5.4.600.20.1.8

This attribute defines the location name of the voltage probe.

String64

Read-only

Table 89. Voltage Probe Upper Non Recoverable Threshold

Name

Object ID

Description

Syntax

Access voltageProbeUpperNonRecoverableThreshold

1.3.6.1.4.1.674.10892.5.4.600.20.1.9

This attribute defines the upper non-recoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.

Signed32BitRange

Read-only

Table 90. Voltage Probe Upper Critical Threshold

Name voltageProbeUpperCriticalThreshold

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.5.4.600.20.1.10

This attribute defines the upper critical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.

Signed32BitRange

Read-only

Table 91. Voltage Probe Upper NonCritical Threshold

Name

Object ID

Description

Syntax

Access voltageProbeUpperNonCriticalThreshold

1.3.6.1.4.1.674.10892.5.4.600.20.1.11

This attribute defines the upper noncritical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.

Signed32BitRange

Read-only

Table 92. Voltage Probe Lower NonCritical Threshold

Name

Object ID

Description

Syntax voltageProbeLowerNonCriticalThreshold

1.3.6.1.4.1.674.10892.5.4.600.20.1.12

This attribute defines the lower noncritical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.

Signed32BitRange

30 Introduction

Table 92. Voltage Probe Lower NonCritical Threshold (continued)

Access Read-only

Table 93. Voltage Probe Lower Critical Threshold

Name

Object ID

Description

Syntax

Access voltageProbeLowerCriticalThreshold

1.3.6.1.4.1.674.10892.5.4.600.20.1.13

This attribute defines the lower critical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.

Signed32BitRange

Read-only

Table 94. Voltage Probe Lower NonRecoverable Threshold

Name

Object ID

Description

Syntax

Access voltageProbeLowerNonRecoverableThreshold

1.3.6.1.4.1.674.10892.5.4.600.20.1.14

This attribute defines the lower non-recoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.

Signed32BitRange

Read-only

Table 95. Voltage Probe Probe Capabilities

Name

Object ID

Description

Syntax

Access voltageProbeProbeCapabilities

1.3.6.1.4.1.674.10892.5.4.600.20.1.15

This attribute defines the probe capabilities of the voltage probe.

ProbeCapabilitiesFlags

Read-only

Table 96. Voltage Probe Discrete Reading

Name

Object ID

Description

Syntax

Access voltageProbeDiscreteReading

1.3.6.1.4.1.674.10892.5.4.600.20.1.16

This attribute defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.

VoltageDiscreteReadingEnum

Read-only

System Information Group

The System Information Group objects provide information about the system in which the iDRAC resides.

Table 97. System Fully Qualified Domain Name

Name

Object ID

Description systemFQDN

1.3.6.1.4.1.674.10892.5.1.3.1.0

This attribute defines the fully qualified domain name of the system.

Introduction 31

Table 97. System Fully Qualified Domain Name (continued)

Syntax

Access

StringType

Read-only

Table 98. System Service Tag

Name

Object ID

Description

Syntax

Access systemServiceTag

1.3.6.1.4.1.674.10892.5.1.3.2.0

This attribute defines the service tag of the system.

StringType

Read-only

Table 99. System Express Service Code

Name

Object ID

Description

Syntax

Access systemExpressServiceCode

1.3.6.1.4.1.674.10892.5.1.3.3.0

This attribute defines the express service code of the system.

StringType

Read-only

Table 100. System Asset Tag

Name

Object ID

Description .

Syntax

Access systemAssetTag

1.3.6.1.4.1.674.10892.5.1.3.4.0

This attribute defines the asset tag of the system.

StringType

Read-only

Table 101. System Blade Slot Number

Name

Object ID

Description

Syntax

Access systemBladeSlotNumber

1.3.6.1.4.1.674.10892.5.1.3.5.0

This attribute defines the slot number of the blade in the chassis.

StringType

Read-only

Table 102. System Operating System Name

Name systemOSName

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.5.1.3.6.0

This attribute defines the name of the operating system that the host is running.

StringType

Read-only

Table 103. System Form Factor

Name

Object ID

Description systemFormFactor

1.3.6.1.4.1.674.10892.5.1.3.7.0

This attribute defines the form factor of the system.

32 Introduction

Table 103. System Form Factor (continued)

Syntax

Access

SystemFormFactorEnum

Read-only

Table 104. System Data Center Name

Name

Object ID

Description

Syntax

Access systemDataCenterName

1.3.6.1.4.1.674.10892.5.1.3.8.0

This attribute defines the Data Center locator of the system.

StringType

Read-only

Table 105. System Aisle Name

Name

Object ID

Description

Syntax

Access systemAisleName

1.3.6.1.4.1.674.10892.5.1.3.9.0

This attribute defines the Aisle locator of the system.

StringType

Read-only

Table 106. System Rack Name

Name

Object ID

Description

Syntax

Access systemRackName

1.3.6.1.4.1.674.10892.5.1.3.10.0

This attribute defines the Rack locator of the system.

StringType

Read-only

Table 107. System Rack Slot

Name

Object ID

Description

Syntax

Access systemRackSlot

1.3.6.1.4.1.674.10892.5.1.3.11.0

This attribute defines the Rack Slot locator of the system.

StringType

Read-only

Table 108. System Model Name

Name systemModelName

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.5.1.3.12.0

This attribute defines the model name of the system.

StringType

Read-only

Table 109. System System ID

Name

Object ID

Description systemSystemID

1.3.6.1.4.1.674.10892.5.1.3.13.0

This attribute defines the system ID of the system.

Introduction 33

Table 109. System System ID (continued)

Syntax

Access

Unsigned16BitRange

Read-only

Table 110. System OS Version

Name

Object ID

Description

Syntax

Access systemOSVersion

1.3.6.1.4.1.674.10892.5.1.3.14.0

This attribute defines the version of the operating system that the host is running.

StringType

Read-only

Table 111. System Room Name

Name

Object ID

Description

Syntax

Access systemRoomName

1.3.6.1.4.1.674.10892.5.1.3.15.0

This attribute defines the Room locator of the system.

StringType

Read-only

Table 112. System Chassis System Height

Name

Object ID

Description

Syntax

Access systemChassisSystemHeight

1.3.6.1.4.1.674.10892.5.1.3.16.0

This attribute defines the height of the system, in 'U's. A U is a standard unit of measure for the height of a rack or rack-mountable component.

INTEGER

Read-only

Table 113. System Blade Geometry

Name

Object ID

Description

Syntax

Access systemBladeGeometry

1.3.6.1.4.1.674.10892.5.1.3.17.0

This attribute defines the blade geometry for a blade system. (If not applicable, a 'no such name' error is returned.)

BladeGeometryEnum

Read-only

Table 114. System Node ID

Name

Object ID

Description

Syntax

Access systemNodeID

1.3.6.1.4.1.674.10892.5.1.3.18.0

This attribute defines the node ID of the system. The node ID provides a unique identifier for the system.

StringType

Read-only

Table 115. System OEM OS Version

Name systemOEMOSVersion

34 Introduction

Table 115. System OEM OS Version (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.5.1.3.19.0

This attribute defines the OEM version of the operating system.

StringType

Read-only

Table 116. System Lockdown Mode

Name

Object ID

Description

Syntax

Access systemLockdownMode

1.3.6.1.4.1.674.10892.5.1.3.20.0

This attribute defines the system Lockdown mode is enabled or disabled.

SystemLockdownModeEnum

Read-only

Introduction 35

2

Server Administrator Group

The Server Administrator group comprises of the following sections:

Instrumentation MIB Version Group

Systems Management Software Group

System State Group

Chassis Information Group

Operating System Group

System Resource Group

Power Group

Thermal Group

Remote Flash BIOS Group

Port Group

Device Group

Slot Group

Memory Group

BIOS Setup Control Group

Local Response Agent Group

Cost of Ownership Group

Cluster Group

Baseboard Management Controller Group

Field Replaceable Unit Group

Topics:

Instrumentation MIB Version Group

Systems Management Software Group

System State Group

Chassis Information Group

Operating System Group

System Resource Group

Power Group

Thermal Group

Remote Flash BIOS Group

Port Group

Device Group

Slot Group

Memory Group

BIOS Setup Control Group

Local Response Agent Group

Cost of Ownership Group

Cluster Group

Baseboard Management Controller Group

Field Replaceable Unit Group

Instrumentation MIB Version Group

The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the

Instrumentation MIB supported by the systems management software.

The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table.

36 Server Administrator Group

Management Information Base Major Version Number

Table 117. Management Information Base Major Version Number

Name

Object ID

Description mIBMajorVersionNumber

1.3.6.1.4.1.674.10892.1.1.1.0

Defines the major version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the major version number is 1.

A major version number change indicates a major change in object functionality.

Syntax

Access

DellUnsigned8BitRange

Read-only

Management Information Base Minor Version Number

Table 118. Management Information Base Minor Version Number

Name

Object ID

Description mIBMinorVersionNumber

1.3.6.1.4.1.674.10892.1.1.2.0

Defines the minor version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2.

A minor revision provides additional support for new objects as well as problem fixes.

Syntax

Access

DellUnsigned8BitRange

Read-only

Management Information Base Maintenance Version Number

Table 119. Management Information Base Maintenance Version Number

Name

Object ID

Description

Syntax

Access mIBMaintenanceVersionNumber

1.3.6.1.4.1.674.10892.1.1.3.0

Defines the maintenance version number for the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the maintenance version number is 3.

DellUnsigned8BitRange

Read-only

Systems Management Software Group

The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.

Additional objects define the universal resource locator (URL) of the systems management software and the language in which systems management information displays. Defining these objects enables users to manage a system using an internet browser.

You can access Server Administrator using the secure hypertext transfer protocol (https) and a pre-assigned port number of

1311, or you can specify a port number of your own choosing.

Server Administrator Group 37

NOTE: Using the Software > Server Preferences menu of Server Administrator, you can bind to either one IP address or to all IP addresses.

To manage a system locally using Server Administrator, type the following in the address field of your browser: https:// localhost:<1311 or user-specified port number>

To manage a system remotely using Server Administrator, type one of the following in the address field of your browser: https://<systemname>:<1311 or user specified port number> or https://<IP address>:<1311 or user specified port number>

Systems Management Software

The following objects describe the fields for server administrator systems management information. The systems management software variables are scalar objects, meaning that they are not related to other management information base (MIB) objects and are thus not placed in a table.

Table 120. Systems Management Software Name

Name

Object ID

Description

Syntax

Access systemManagementSoftwareName

1.3.6.1.4.1.674.10892.1.100.1

Defines the systems management software product name.

DellString

Read-only

Table 121. Systems Management Software Version Number Name

Name

Object ID

Description

Syntax

Access systemManagementSoftwareVersionNumberName

1.3.6.1.4.1.674.10892.1.100.2

Defines the version number of the systems management software.

DellString

Read-only

Table 122. Systems Management Software Build Number

Name

Object ID

Description

Syntax

Access systemManagementSoftwareBuildNumber

1.3.6.1.4.1.674.10892.1.100.3

Defines the build number of the systems management software.

DellUnsigned16BitRange

Read-only

Table 123. Systems Management Software Description Name

Name

Object ID

Description

Syntax

Access systemManagementSoftwareDescriptionName

1.3.6.1.4.1.674.10892.1.100.4

Defines the description of the systems management software.

DellString

Read-only

Table 124. Systems Management Software Supported Protocol

Name

Object ID systemManagementSoftwareSupportedProtocol

1.3.6.1.4.1.674.10892.1.100.5

38 Server Administrator Group

Table 124. Systems Management Software Supported Protocol (continued)

Description

Syntax

Access

Defines the systems management standards (SNMP or CIM) supported by the systems management software.

SMSSupportedTypes (

Systems Management Software Supported Standards

)

Read-only

Table 125. Systems Management Software Preferred Protocol

Name

Object ID

Description

Syntax

Access systemManagementSoftwarePreferredProtocol

1.3.6.1.4.1.674.10892.1.100.6

Defines the preferred systems management standard for the systems management software.

SMSSupportedTypes (

Systems Management Software Supported Standards

)

Read-only

Table 126. Systems Management Software Update Level Name

Name

Object ID

Description

Syntax

Access systemManagementSoftwareUpdateLevelName

1.3.6.1.4.1.674.10892.1.100.7

Defines the update level of the system management software.

DellString

Read-only

Table 127. Systems Management Software URL Name

Name

Object ID

Description

Syntax

Access systemManagementSoftwareURLName

1.3.6.1.4.1.674.10892.1.100.8

Defines the universal resource locator (URL) of the systems management software.

DisplayString (SIZE (0..1024))

Read-only

Table 128. Systems Management Software Language Name

Name

Object ID

Description

Syntax

Access systemManagementSoftwareLanguageName

1.3.6.1.4.1.674.10892.1.100.9

Defines the language of the systems management software.

DisplayString (SIZE (0..255))

Read-only

Table 129. Systems Management Software Global Version Name

Name

Object ID

Description

Syntax

Access systemManagementSoftwareGlobalVersionName

1.3.6.1.4.1.674.10892.1.100.10

Defines the global version of the systems management software.

DellString

Read-only

Table 130. Systems Management Software Feature Flags

Name systemManagementSoftwareFeatureFlags

Server Administrator Group 39

Table 130. Systems Management Software Feature Flags (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.100.11

Defines the features of the systems management software.

SMSFeatureFlags ( Systems Management Software Feature Flags

)

Read-only

Table 131. Systems Management Software SNMP Agent Feature Flags

Name

Object ID

Description

Syntax

Access systemManagementSoftwareSNMPAgentFeatureFlags

1.3.6.1.4.1.674.10892.1.100.12

Defines the features of the SNMP agent software provided by the operating system.

SMSSNMPAgentFeatureFlags (

Systems Management Software SNMP Agent Feature

Flags )

Read-only

Table 132. Systems Management Software Manufacturer Name

Name

Object ID

Description

Syntax

Access systemManagementSoftwareManufacturerName

1.3.6.1.4.1.674.10892.1.100.13

Defines the manufacturer of the systems management software.

DellString

Read-only

Systems Management Software Variable Values

This section includes definitions of server administrator-specific variable values used in this section.

Table 133. Systems Management Software Supported Standards

Variable Name : SMSSupportedTypes

Data Type : Integer

Possible Data Values supportsSNMP(1) supportsDMI(2)

Meaning of Data Value

This system supports SNMP.

This system supports DMI.

supportsSNMPandDMI(3) supportsCIMOM(4) supportsSNMPandCIMOM(5)

This system supports SNMP and DMI.

This system supports CIM.

This system supports SNMP and CIM.

Table 134. Systems Management Software Feature Flags

Variable Name : SMSFeatureFlags .

Data Type : Integer

Possible Data Values Meaning of Data Value none(0) webOneToOneManagementPrefe rred(1)

The Systems Management Software features are not enabled.

The web 1:1 management preferred feature is enabled

40 Server Administrator Group

Table 135. Systems Management Software SNMP Agent Feature Flags

Variable Name : SMSSNMPAgentFeatureFlags

Data Type : Integer

Possible Data Values none(0) supportsSparseTables(1)

Meaning of Data Value

The Systems Management Software SNMP agent features are not enabled.

The SNMP agent supports sparse tables.

System State Group

The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes.

System State Group Table

The System State Group defines objects in the System State MIB table.

System State Table

The systemStateGlobalSystemStatus variable provides overall system health status and includes rolled-up (that is, worst) status for Instrumentation and Storage. This variable monitors the overall system health status. It reflects changes to systemStateChassisStatus variable, which represents Instrumentation health status and agentGlobalSystemStatus

( dcstorag.mib

), which represents Storage health status.

The systemStateChassisStatus variable provides the rolled-up health status for the subsystems associated with the chassis that is represented by the row in the systemStateTable

. Changes to the variables in List 1 , each of which indicates the

rolled-up health status of all the components of the corresponding subsystem, are reflected in systemStateChassisStatus variable.

For example, systemStatePowerSupplyStatusCombined provides the rolled up status of all power supplies for the chassis.

The variables in

List 2

provide the health status of each component of the corresponding subsystem.

Each octet of the value represents a component. If a power supply fails, the corresponding entry in systemStatePowerSupplyStatusDetails , systemStatePowerSupplyStatusCombined , systemStateChassisStatus and systemStateGlobalSystemStatus transitions to critical.

List 1

Variables that provide rolled-up health status for all components in associated subsystem in chassis:

● systemStatePowerSupplyStatusCombined

● systemStateVoltageStatusCombined

● systemStateAmperageStatusCombined

● systemStateCoolingDeviceStatusCombined

● systemStateTemperatureStatusCombined

● systemStateMemoryDeviceStatusCombined

● systemStateChassisIntrusionStatusCombined

● systemStateACPowerCordStatusCombined

● systemStateEventLogStatus

● systemStatePowerUnitStatusCombined

● systemStateCoolingUnitStatusCombined

● systemStateACPowerSwitchStatusCombined

● systemStateRedundantMemoryUnitStatusCombined

● systemStateProcessorDeviceStatusCombined

Server Administrator Group 41

● systemStateBatteryStatusCombined

● systemStateSDCardUnitStatusCombined

● systemStateSDCardDeviceStatusCombined

List 2

Variables that provide health status of each component in associated subsystem in chassis:

● systemStatePowerSupplyStatusDetails

● systemStateVoltageStatusDetails

● systemStateAmperageStatusDetails

● systemStateCoolingDeviceStatusDetails

● systemStateTemperatureStatusDetails

● systemStateMemoryDeviceStatusDetails

● systemStateChassisIntrusionStatusDetails

● systemStateACPowerCordStatusDetails

● systemStatePowerUnitStatusList

● systemStateCoolingUnitStatusList

● systemStateACPowerSwitchStatusList

● systemStateRedundantMemoryUnitStatusList

● systemStateProcessorDeviceStatusList

● systemStateBatteryStatusList

● systemStateSDCardUnitStatusList

● systemStateSDCardDeviceStatusList

System State Table

The following object sets up the System State Table:

Table 136. System State Table

Name

Object ID

Description

Syntax

Access systemStateTable

1.3.6.1.4.1.674.10892.1.200.10

Defines the System State Table.

SEQUENCE OF SystemStateTableEntry

Not accessible

Table 137. System State Table Entry

Name

Object ID

Description

Syntax

Access

Index systemStateTableEntry

1.3.6.1.4.1.674.10892.1.200.10.1

Defines the System State Table entry.

SystemStateTableEntry

Not accessible systemStatechassisIndex

Table 138. System State Chassis Index

Name

Object ID

Description

Syntax systemStatechassisIndex

1.3.6.1.4.1.674.10892.1.200.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

42 Server Administrator Group

Table 138. System State Chassis Index (continued)

Access Read-only

Table 139. System State Global System Status

Name

Object ID

Description

Syntax

Access systemStateGlobalSystemStatus

1.3.6.1.4.1.674.10892.1.200.10.1.2

Defines the global system status of all chassis being monitored by this instrumentation instance.

DellStatus

Read-only

Table 140. System State Chassis State

Name

Object ID

Description

Syntax

Access systemStateChassisState

1.3.6.1.4.1.674.10892.1.200.10.1.3

Defines the system state of this chassis.

DellStateSettings

Read-only

Table 141. System State Chassis Status

Name

Object ID

Description

Syntax

Access systemStateChassisStatus

1.3.6.1.4.1.674.10892.1.200.10.1.4

Defines the system status of this chassis.

DellStatus

Read-only

Table 142. System State Power Unit State Details

Name

Object ID

Description

Syntax

Access systemStatePowerUnitStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.5

Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit.

The first byte returned represents the state of the first power unit, the second byte returned represents the state of the second power unit, and so on. The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 143. System State Power Unit Status Redundancy

Name

Object ID

Description

Syntax

Access systemStatePowerUnitStatusRedundancy

1.3.6.1.4.1.674.10892.1.200.10.1.6

Defines the system status of the power unit(s) in this chassis.

DellStatus

Read-only

Table 144. System State Power Unit Status Details

Name systemStatePowerUnitStatusDetails

Server Administrator Group 43

Table 144. System State Power Unit Status Details (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.200.10.1.7

Defines the status of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific power unit. The first byte returned represents the status of the first power unit, the second byte returned represents the status of the second power unit, and so on. The bytes have the same definition type as DellStatusRedundancy.

Octet String

Read-only

Table 145. System State Power Supply State Details

Name

Object ID

Description

Syntax

Access systemStatePowerSupplyStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.8

Defines the state of all power supplies in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power supply. The first byte returned represents the state of the first power supply, the second byte returned represents the state of the second power supply, and so on. The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 146. System State Power Supply Status Combined

Name

Object ID

Description

Syntax

Access systemStatePowerSupplyStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.9

Defines the status of all power supplies in this chassis.

DellStatus

Read-only

Table 147. System State Power Supply Status Details

Name

Object ID

Description

Syntax

Access systemStatePowerSupplyStatusDetails

1.3.6.1.4.1.674.10892.1.200.10.1.10

Defines the status of all power supplies in this chassis. The results are returned as a binary octet string, Each byte of the octet string represents the status of a specific power supply. The first byte returned represents the status of the first power supply, the second byte returned represents the status of the second power supply, and so on.

The bytes have the same definition type as DellStatus.

Octet String (Size (1..128))

Read-only

Table 148. System State Voltage State Details

Name

Object ID

Description

Syntax systemStateVoltageStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.11

Defines the state of all voltage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific voltage probe. The first byte returned represents the status of the first voltage probe, the second byte returned represents the status of the second voltage probe, and so on.

The bytes have the same definition type as DellStateSettings.

Octet String

44 Server Administrator Group

Table 148. System State Voltage State Details (continued)

Access Read-only

Table 149. System State Voltage Status Combined

Name

Object ID

Description

Syntax

Access systemStateVoltageStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.12

Defines the status of all voltage probes in this chassis.

DellStatus

Read-only

Table 150. System State Voltage Status Details

Name

Object ID

Description

Syntax

Access systemStateVoltageStatusDetails

1.3.6.1.4.1.674.10892.1.200.10.1.13

Defines the status of all voltage probes in this chassis.

Octet String

Read-only

Table 151. System State Amperage State Details

Name systemStateAmperageStateDetails

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.200.10.1.14

Defines the state of all current probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific current probe. The first byte returned represents the state of the first current probe, the second byte returned represents the state of the second current probe, and so on.

The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 152. System State Amperage Status Combined

Name

Object ID

Description

Syntax

Access systemStateAmperageStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.15

Defines the status of all amperage probes in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus.

DellStatus

Read-only

Table 153. System State Amperage Status Details

Name

Object ID

Description

Syntax

Access systemStateAmperageStatusDetails

1.3.6.1.4.1.674.10892.1.200.10.1.16

Defines the status of all amperage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific amperage probe. The first byte returned represents the status of the first amperage probe, the second byte returned represents the status of the second amperage probe, and so on. The bytes have the same definition type as DellStatus.

Octet String

Read-only

Server Administrator Group 45

Table 154. System State Cooling Unit State Details

Name

Object ID

Description

Syntax

Access statesystemStateCoolingUnitStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.17

Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on. The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 155. System State Cooling Unit Status Redundancy

Name

Object ID

Description

Syntax

Access systemStateCoolingUnitStatusRedundancy

1.3.6.1.4.1.674.10892.1.200.10.1.18

Defines the state of all cooling units in this chassis.

DellStatusRedundancy

Read-only

Table 156. System State Cooling Unit State Details

Name systemStateCoolingUnitstateDetails

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.200.10.1.19

Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on. The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 157. System State Cooling Device State Details

Name

Object ID

Description

Syntax

Access systemStateCoolingDeviceStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.20

Defines the state of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling device. The first byte returned represents the state of the first cooling device, the second byte returned represents the state of the second cooling device, and so on.

The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 158. System State Cooling Device Status Combined

Name

Object ID

Description

Syntax systemStateCoolingDeviceStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.21

This attribute defines the cooling device status of all cooling devices in this chassis. The results is returned as a combined status value. The value has the same definition type as

DellStatus.

DellStatus

46 Server Administrator Group

Table 158. System State Cooling Device Status Combined (continued)

Access Read-only

Table 159. System State Cooling Device Status Details

Name

Object ID

Description

Syntax

Access systemStateCoolingDeviceStatusDetails

1.3.6.1.4.1.674.10892.1.200.10.1.22

Defines the status of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific cooling device. The first byte returned represents the status of the first cooling device, the second byte returned represents the status of the second cooling device, and so on.

The bytes have the same definition type as DellStatus.

Octet String

Read-only

Table 160. System State Temperature State Details

Name

Object ID

Description

Syntax

Access systemStateTemperatureStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.23

Defines the state of all temperature probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific temperature probe. The first byte returned represents the state of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on. The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 161. System State Temperature Status Combined

Name

Object ID

Description

Syntax

Access systemStateTemperatureStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.24

Defines the status of all temperature probes in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus.

DellStatus

Read-only

Table 162. System State Temperature Status Details

Name

Object ID

Description

Syntax

Access systemStateTemperatureStatusDetailsly

1.3.6.1.4.1.674.10892.1.200.10.1.25

Defines the status of all temperature probes in this chassis. The first byte returned represents the status of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on.

Octet String

Read-only

Table 163. System State Memory Device State Details

Name

Object ID

Description systemStateMemoryDeviceStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.26

Defines the state of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of the specific

Server Administrator Group 47

Table 163. System State Memory Device State Details (continued)

Syntax

Access memory device. The first byte returned represents the state of the first memory device, the second byte returned represents the status of the second memory device, and so on. The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 164. System State Memory Device Status Combined

Name

Object ID

Description

Syntax

Access systemStateMemoryDeviceStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.27

Defines the status of all memory devices in this chassis.

DellStatus

Read-only

Table 165. System State Memory Device Status Details

Name

Object ID

Description

Syntax

Access systemStateMemoryDeviceStatusDetails

1.3.6.1.4.1.674.10892.1.200.10.1.28

Defines the status of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific memory device. The first byte returned represents the status of the first memory device, the second byte returned represents the status of the second memory device, and so on. The bytes have the same definition type as DellStatus.

Octet String

Read-only

Table 166. System State Chassis Intrusion State Details

Name

Object ID

Description

Syntax

Access systemStateChassisIntrusionStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.29

Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device. The first byte returned represents the status of the first intrusion detection device, the second byte returned represents the status of the second intrusion detection device, and so on. The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 167. System State Chassis Intrusion Status Combined

Name

Object ID

Description

Syntax

Access systemStateChassisIntrusionStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.30

Defines the intrusion status of all intrusion detection devices in this chassis. The result is returned as a combined status value. The value has the same definition type as

DellStatus.

DellStatus

Read-only

48 Server Administrator Group

Table 168. System State Chassis Intrusion Status Details

Name

Object ID

Description

Syntax

Access systemStateChassisIntrusionStatusDetails

1.3.6.1.4.1.674.10892.1.200.10.1.31

Defines the intrusion status of all intrusion detection devices in this chassis. The first byte returned represents the status of the first intrusion detection device, the second byte returned represents the status of the second intrusion detection device, and so on.

Octet String

Read-only

Table 169. System State AC Power Switch State Details

Name systemStateACPowerSwitchStateDetails

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.200.10.1.32

Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on.

Octet String

Read-only

Table 170. System State AC Power Switch Status Redundancy

Name systemStateACPowerSwitchStatusRedundancy

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.200.10.1.33

Defines the overall redundancy status of the AC power switches in this chassis.

DellStatusRedundancy

Read-only

Table 171. System State AC Power Switch Status Details

Name

Object ID

Description

Syntax

Access systemStateACPowerSwitchStatusDetails

1.3.6.1.4.1.674.10892.1.200.10.1.34

Defines the individual status of all AC power switches in this chassis. The first byte returned represents the status of the first AC power switch, the second byte returned represents the status of the second AC power switch, and so on.

Octet String

Read-only

Table 172. System State AC Power Cord State Details

Name

Object ID

Description

Syntax

Access systemStateACPowerCordStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.35

Defines the individual state of all AC power cords for any AC power switches in this chassis. The first byte returned represents the state of the first AC power cord, the second byte returned represents the state of the second AC power cord, and so on.

Octet String

Read-only

Table 173. System State AC Power Cord Status Combined

Name systemStateACPowerCordStatusCombined

Server Administrator Group 49

Table 173. System State AC Power Cord Status Combined (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.200.10.1.36

Defines the overall status of all AC power cords for any AC power switches in this chassis.

DellStatus

Read-only

Table 174. System State AC Power Cord Status Details

Name

Object ID

Description

Syntax

Access systemStateACPowerCordStatusDetails

1.3.6.1.4.1.674.10892.1.200.10.1.37

Defines the individual status of all AC power cords for any AC power switches in this chassis. The first byte returned represents the status of the first AC power cord, the second byte returned represents the status of the second AC power cord, and so on.

Octet String

Read-only

Table 175. System State Redundant Memory Unit State Details

Name

Object ID

Description

Syntax

Access systemStateRedundantMemoryUnitStateDetails

1.3.6.1.4.1.674.10892.1.200.10.1.38

Defines the state of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on. The bytes have the same definition type as DellStateSettings.

Octet String

Read-only

Table 176. System State Redundant Memory Unit Status Redundancy

Name

Object ID

Description

Syntax

Access systemStateRedundantMemoryUnitStatusRedundancy

1.3.6.1.4.1.674.10892.1.200.10.1.39

Defines the overall redundancy status for redundant memory.

DellStatusRedundancy

Read-only

Table 177. System State Redundant Memory Unit Status Details

Name

Object ID

Description

Syntax

Access systemStateRedundantMemoryUnitStatusDetails

1.3.6.1.4.1.674.10892.1.200.10.1.40

Defines the status of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the status of the specific object. The first byte returned represents the status of the first object, and so on. The bytes have the same definition type as DellStatusRedundancy.

Octet String

Read-only

Table 178. System State Event Log Status

Name

Object ID systemStateEventLogStatus

1.3.6.1.4.1.674.10892.1.200.10.1.41

50 Server Administrator Group

Table 178. System State Event Log Status (continued)

Description

Syntax

Access

Defines the overall status of this chassis (ESM) event log.

DellStatus

Read-only

Table 179. System State Power Unit Status Combined

Name

Object ID

Description

Syntax

Access systemStatePowerUnitStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.42

Defines the combined status of all power units of this chassis.

DellStatus

Read-only

Table 180. System State Power Unit Status List

Name

Object ID

Description

Syntax

Access systemStatePowerUnitStatusList

1.3.6.1.4.1.674.10892.1.200.10.1.43

Lists the status of each power unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a power unit.

The first byte returned represents the status of the first power unit, and so on. The bytes have the same definition type as DellStatus.

Octet String

Read-only

Table 181. System State Cooling Unit Status Combined

Name systemStateCoolingUnitStatusCombined

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.200.10.1.44

Defines the combined status of all cooling units of this chassis.

DellStatus

Read-only

Table 182. System State Cooling Unit Status List

Name

Object ID

Description

Syntax

Access systemStateCoolingUnitStatusList

1.3.6.1.4.1.674.10892.1.200.10.1.45

Lists the status of each cooling unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit.

The first byte returned represents the status of the first cooling unit, and so on. The bytes have the same definition type as DellStatus.

Octet String

Read-only

Table 183. System State AC Power Switch Status Combined

Name

Object ID

Description

Syntax

Access systemStateACPowerSwitchStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.46

Defines the combined status of all AC power switches of this chassis.

DellStatus

Read-only

Server Administrator Group 51

Table 184. System State AC Power Switch Status List

Name

Object ID

Description

Syntax

Access systemStateACPowerSwitchStatusList

1.3.6.1.4.1.674.10892.1.200.10.1.47

Lists the status of each AC power switch of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of an

AC power switch. The first byte returned represents the status of the first AC power switch, and so on. The bytes have the same definition type as DellStatus.

Octet String

Read-only

Table 185. System State Redundant Memory Unit Status Combined

Name

Object ID

Description

Syntax

Access systemStateRedundantMemoryUnitStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.48

Defines the combined status of all redundant memory units of this chassis.

DellStatus

Read-only

Table 186. System State Redundant Memory Unit Status List

Name

Object ID

Description

Syntax

Access systemStateRedundantMemoryUnitStatusList

1.3.6.1.4.1.674.10892.1.200.10.1.49

Lists the status of each redundant memory unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a redundant memory unit. The first byte returned represents the status of the first redundant memory unit, and so on. The bytes have the same definition type as

DellStatus.

Octet String

Read-only

Table 187. System State Processor Device Status Combined

Name

Object ID

Description

Syntax

Access systemStateProcessorDeviceStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.50

Defines the combined status of all processor devices of this chassis.

DellStatus

Read-only

Table 188. System State Processor Device Status List

Name

Object ID

Description

Syntax

Access systemStateProcessorDeviceStatusList

1.3.6.1.4.1.674.10892.1.200.10.1.51

Lists the status of each processor device of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a processor device. The first byte returned represents the status of the first processor device, and so on. The bytes have the same definition type as DellStatus.

Octet String

Read-only

52 Server Administrator Group

Table 189. System State Battery Status Combined

Name

Object ID

Description

Syntax

Access systemStateBatteryStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.52

Defines the combined status of all batteries of this chassis.

DellStatus

Read-only

Table 190. System State Battery Status List

Name

Object ID

Description

Syntax

Access systemStateBatteryStatusList

1.3.6.1.4.1.674.10892.1.200.10.1.53

Lists the status of each battery of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, and so on. The bytes have the same definition type as DellStatus.

Octet String

Read-only

Table 191. System State SD Card Unit Status Combined

Name

Object ID

Description

Syntax

Access systemStateSDCardUnitStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.54

Defines the combined status of all SD Card units of this chassis.

DellStatus

Read-only

Table 192. System State SD Card Unit Status List

Name

Object ID

Description

Syntax

Access systemStateSDCardUnitStatusList

1.3.6.1.4.1.674.10892.1.200.10.1.55

Lists the status of each SD Card unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD

Card unit. The first byte returned represents the status of the first SD Card unit, and so on. The bytes have the same definition type as DellStatus.

Octet String

Read-only

Table 193. System State SD Card Device Status Combined

Name

Object ID

Description

Syntax

Access systemStateSDCardDeviceStatusCombined

1.3.6.1.4.1.674.10892.1.200.10.1.56

Defines the combined status of all SD Card devices of this chassis.

DellStatus

Read-only

Table 194. System State SD Card Device Status List

Name

Object ID systemStateSDCardDeviceStatusList

1.3.6.1.4.1.674.10892.1.200.10.1.57

Server Administrator Group 53

Table 194. System State SD Card Device Status List (continued)

Description

Syntax

Access

Lists the status of each SD Card device of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD

Card device. The first byte returned represents the status of the first SD Card device, and so on. The bytes have the same definition type as DellStatus.

Octet String

Read-only

Chassis Information Group

The Chassis Information Group provides information about the type or types of chassis in your system, as well as information about the light-emitting diode (LED) indicators and settings for devices on each chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on.

Chassis Information Group Tables

The following management information base (MIB) tables define the objects in the Chassis Information Group:

Chassis Information Table

UUID Table

POST Log Table

Event Log Table

System BIOS Table

Firmware Table

Intrusion Table

Baseboard Table

Chassis Information Table

The following object sets up the Chassis Information Table.

Table 195. Chassis Information Table

Name chassisInformationTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.300.10

Defines the chassis information table.

SEQUENCE OF ChassisInformationTableEntry

Not accessible

Table 196. Chassis Information Table Entry

Name

Object ID

Description

Syntax

Access

Index chassisInformationTableEntry

1.3.6.1.4.1.674.10892.1.300.10.1

Defines the chassis information table entry.

ChassisInformationTableEntry

Not accessible chassisIndexChassisInformation

Table 197. Chassis Index Chassis Information

Name chassisIndexChassisInformation

54 Server Administrator Group

Table 197. Chassis Index Chassis Information (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.300.10.1.1

Defines the index (one-based) of this chassis. The first chassis is numbered one.

DellObjectRange

Read-only

Table 198. Chassis State Capabilities

Name

Object ID

Description

Syntax

Access chassisStateCapabilities

1.3.6.1.4.1.674.10892.1.300.10.1.2

Defines the capabilities of the chassis.

DellStateCapabilities

Read-only

Table 199. Chassis State Settings

Name

Object ID

Description

Syntax

Access chassisStateSettings

1.3.6.1.4.1.674.10892.1.300.10.1.3

Defines the state settings for the chassis.

DellStateSettings

Read-only

Table 200. Chassis Status

Name

Object ID

Description

Syntax

Access chassisStatus

1.3.6.1.4.1.674.10892.1.300.10.1.4

Defines the status of the chassis.

DellStatus

Read-only

Table 201. Chassis Parent Index Reference

Name

Object ID

Description

Syntax

Access chassisparentIndexReference

1.3.6.1.4.1.674.10892.1.300.10.1.4

Defines the index (one-based) of the parent chassis of this chassis, if any. A zero

(0) means that this chassis is the parent of all other chassis managed by the Server

Administrator.

DellObjectRange

Read-only

Table 202. Chassis Type

Name

Object ID

Description

Syntax

Access chassisType

1.3.6.1.4.1.674.10892.1.300.10.1.6

Defines the chassis type.

DellChassisType (See

Chassis Type )

Read-only

Server Administrator Group 55

Table 203. Chassis Name

Name

Object ID

Description

Syntax

Access chassisName

1.3.6.1.4.1.674.10892.1.300.10.1.7

Defines the user-assigned chassis name of the chassis.

DellString

Read-only

Table 204. Chassis Manufacturer Name

Name

Object ID

Description

Syntax

Access chassisManufacturerName

1.3.6.1.4.1.674.10892.1.300.10.1.8

Defines the manufacturer’s name for this chassis.

DellString

Read-only

Table 205. Chassis Model Name

Name

Object ID

Description

Syntax

Access chassisModelName

1.3.6.1.4.1.674.10892.1.300.10.1.9

Defines the system model type for this chassis.

DellString

Read-only

Table 206. Chassis Asset Tag Name

Name

Object ID

Description

Syntax

Access chassisAssetTagName

1.3.6.1.4.1.674.10892.1.300.10.1.10

Defines the user-assigned asset tag name for this chassis.

DisplayString

Read-only

Table 207. Chassis Service Tag Name

Name

Object ID

Description

Syntax

Access chassisServiceTagName

1.3.6.1.4.1.674.10892.1.300.10.1.11

Defines the service tag name for this chassis.

DisplayString

Read-only

Table 208. Chassis ID

Name

Object ID

Description

Syntax

Access chassisID

1.3.6.1.4.1.674.10892.1.300.10.1.12

Defines the asset tag name for this chassis.

DellUnsigned8BitRange

Read-only

56 Server Administrator Group

Table 209. Chassis ID Extension

Name

Object ID

Description

Syntax

Access chassisIDExtension

1.3.6.1.4.1.674.10892.1.300.10.1.13

Defines the SMBIOS machine ID of this chassis.

DellUnsigned16BitRange

Read-only

Table 210. Chassis System Class

Name

Object ID

Description

Syntax

Access chassisSystemClass

1.3.6.1.4.1.674.10892.1.300.10.1.14

Defines the chassis class of this chassis.

DellChassisSystemClass (See

Chassis Type

)

Read-only

Table 211. Chassis System Name

Name

Object ID

Description

Syntax

Access chassisSystemName

1.3.6.1.4.1.674.10892.1.300.10.1.15

Defines the system name of this chassis.

DellString

Read-only

Table 212. Chassis System Boot Date Name

Name

Object ID

Description

Syntax

Access chassisSystemBootDateName

1.3.6.1.4.1.674.10892.1.300.10.1.16

Defines the boot time of this system.

DellDateName

Read-only

Table 213. Chassis System Date Name

Name

Object ID

Description

Syntax

Access chassisSystemDateName

1.3.6.1.4.1.674.10892.1.300.10.1.17

Defines the current time on this system.

DellDateName

Read-only

Table 214. Chassis System Location Name

Name

Object ID

Description

Syntax

Access chassisSystemLocationName

1.3.6.1.4.1.674.10892.1.300.10.1.18

Defines the user-assigned location for this chassis.

DellString

Read-only

Server Administrator Group 57

Table 215. Chassis System Primary User Name

Name

Object ID

Description

Syntax

Access chassisSystemPrimaryUserName

1.3.6.1.4.1.674.10892.1.300.10.1.19

Defines the user-assigned primary user name for this chassis.

DellString

Read-only

Table 216. Chassis System User Phone Number Name

Name

Object ID

Description

Syntax

Access chassisSystemUserPhoneNumberName

1.3.6.1.4.1.674.10892.1.300.10.1.20

Defines the user-assigned phone number of the primary user of the system.

DellString

Read-only

Table 217. Chassis Connection Status Unique

Name

Object ID

Description

Syntax

Access chassisConnectionStatusUnique

1.3.6.1.4.1.674.10892.1.300.10.1.21

Defines the status of the connection from the system chassis to an expansion chassis.

DellConnectionStatus (See

Connection Status

)

Read-only

Table 218. Chassis Fan Control Capabilities Unique

Name

Object ID

Description

Syntax

Access chassisFanControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.300.10.1.22

Defines the capabilities of the fan control function in this chassis.

DellFanControlCapabilities (See

Fan Control Capabilities

)

Read-only

Table 219. Chassis Fan Control Settings Unique

Name

Object ID

Description

Syntax

Access chassisFanControlSettingsUnique

1.3.6.1.4.1.674.10892.1.300.10.1.23

Defines the readings and settings of the fan control hardware in the chassis.

DellFanControlSettings

Read-only

Table 220. Chassis LED Control Capabilities Unique

Name

Object ID

Description

Syntax

Access chassisLEDControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.300.10.1.24

Defines the capabilities of the LED control function in the chassis.

DellLEDControlCapabilities (See

Front-Panel LED Control CapabilitiesVariable

)

Read-only

58 Server Administrator Group

Table 221. Chassis LED Control Settings Unique

Name

Object ID

Description

Syntax

Access chassisLEDControlSettingsUnique

1.3.6.1.4.1.674.10892.1.300.10.1.25

Defines the readings and settings of the LED control hardware in the chassis.

DellLEDControlSettings (See Front-Panel LED Control Settings

)

Read-only

Table 222. Chassis Hard-Drive (HD) Fault Clear Control Capabilities

Name

Object ID

Description

Syntax

Access chassisHDFaultClearControlCapabilities

1.3.6.1.4.1.674.10892.1.300.10.1.26

Specifies whether the chassis allows reset of the chassis hard-drive fault LED.

DellHDFaultLEDControlCapabilities (See

Hard-Drive Fault LED Control Capabilities

)

Read-only

Table 223. Chassis HD Fault Clear Control Settings

Name

Object ID

Description

Syntax

Access chassisHDFaultClearControlSettings

1.3.6.1.4.1.674.10892.1.300.10.1.27

Allows reset of the chassis hard-drive fault LED.

DellHDFaultLEDControlSettings (See

Hard-Drive Fault LED Control Settings

)

Read-only

Table 224. Chassis Identify Flash Control Capabilities

Name

Object ID

Description

Syntax

Access chassisIdentifyFlashControlCapabilities

1.3.6.1.4.1.674.10892.1.300.10.1.28

Specifies whether the chassis front-panel LED can be set to flash.

DellChassisIdentifyControlCapabilities (See

Chassis Identification Control Capabilities

)

Read-only

Table 225. Chassis Identify Flash Control Settings

Name

Object ID

Description

Syntax

Access chassisIdentifyFlashControlSettings

1.3.6.1.4.1.674.10892.1.300.10.1.29

Causes the chassis front-panel LED to flash.

DellChassisIdentifyControlSettings (See Chassis Identification Control Capabilities )

Read-only

Table 226. Chassis Lock Present

Name

Object ID

Description

Syntax

Access chassisLockPresent

1.3.6.1.4.1.674.10892.1.300.10.1.30

Specifies whether a chassis lock is present on the chassis.

DellBoolean

Read-only

Server Administrator Group 59

Table 227. Chassis Host Control Capabilities Unique

Name

Object ID

Description

Syntax

Access chassishostControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.300.10.1.31

Defines the capabilities of the host control object.

DellHostControlCapabilities (See

Host Control Capabilities )

Read-only

Table 228. Chassis Host Control Settings Unique

Name

Object ID

Description

Syntax

Access chassishostControlSettingsUnique

1.3.6.1.4.1.674.10892.1.300.10.1.32

Defines the current settings of the host control object.

DellHostControlSettings (See Host Control Settings

)

Read-only

Table 229. Chassis Watchdog Control Capabilities Unique

Name

Object ID

Description

Syntax

Access chassiswatchDogControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.300.10.1.33

Defines the capabilities of the watchdog timer object.

DellWatchDogControlCapabilities (See

Watchdog Control Capabilities

)

Read-only

Table 230. Chassis Watchdog Control Settings Unique

Name

Object ID

Description

Syntax

Access chassiswatchDogControlSettingsUnique

1.3.6.1.4.1.674.10892.1.300.10.1.34

Defines the current settings and the values allowed to be set for the watchdog timer object.

DellWatchDogControlCapabilities (See

Watchdog Control Capabilities

)

Read-only

Table 231. Chassis Watchdog Control Expiry Time Capabilities Unique

Name

Object ID

Description

Syntax

Access chassiswatchDogControlExpiryTimeCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.300.10.1.35

Defines the capabilities of the watchdog expiry timer object.

DellWatchDogTimerCapabilities (See Watchdog Timer Capabilities

)

Read-only

Table 232. Chassis Watchdog Control Expiry Time

Name

Object ID

Description

Syntax

Access chassiswatchDogControlExpiryTime

1.3.6.1.4.1.674.10892.1.300.10.1.36

Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object.

DellUnsigned16BitRange

Read-only

60 Server Administrator Group

Table 233. Chassis Allow Set Commands From SNMP

Name

Object ID

Description

Syntax

Access chassisallowSETCommandsfromSNMP

1.3.6.1.4.1.674.10892.1.300.10.1.37

Specifies whether Simple Network Management Protocol (SNMP) Set type commands are allowed by Server Administrator. This attribute does not reflect whether SNMP Set type commands are allowed by the SNMP primary agent.

DellBoolean

Read-only

Table 234. Chassis Power Button Control Capabilities Unique

Name chassisPowerButtonControlCapabilitiesUnique

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.300.10.1.38

Defines the capabilities of the power button control function.

DellPowerButtonControlCapabilities (See

Power Button Control Capabilities

)

Read-only

Table 235. Chassis Power Button Control Settings Unique

Name

Object ID .

Description

Syntax

Access chassisPowerButtonControlSettingsUnique

1.3.6.1.4.1.674.10892.1.300.10.1.39

Defines the current reading and allows setting of the power button control hardware

DellPowerButtonControlSettings (See

Power Button Control Settings )

Read-only

Table 236. Chassis Reseller Name

Name

Object ID

Description

Syntax

Access chassisResellerName

1.3.6.1.4.1.674.10892.1.300.10.1.40

Defines the name of the chassis reseller.

DisplayString

Read-only

Table 237. Chassis Reseller Contact Information Name

Name

Object ID

Description

Syntax

Access chassisResellerContactInformationName

1.3.6.1.4.1.674.10892.1.300.10.1.41

Defines the chassis reseller contact information name.

DisplayString

Read-only

Table 238. Chassis Reseller Product Name

Name

Object ID

Description

Syntax

Access chassisResellerProductName

1.3.6.1.4.1.674.10892.1.300.10.1.42

Defines the chassis reseller product name.

DisplayString

Read-only

Server Administrator Group 61

Table 239. Chassis Reseller System ID

Name

Object ID

Description

Syntax

Access chassisResellerSystemID

1.3.6.1.4.1.674.10892.1.300.10.1.43

Defines the chassis reseller system ID.

DellUnsigned16BitRange

Read-only

Table 240. Chassis NMI Button Control Capabilities Unique

Name

Object ID

Description

Syntax

Access chassisNMIButtonControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.300.10.1.44

Defines the capabilities of the NMI button control function.

DellNMIButtonControlCapabilities (See

NMI Button Control Capabilities

)

Read-only

Table 241. Chassis NMI Button Control Settings Unique

Name

Object ID

Description

Syntax

Access chassisNMIButtonControlSettingsUnique

1.3.6.1.4.1.674.10892.1.300.10.1.45

Defines the current reading and allows setting of the NMI button control hardware.

DellNMIButtonControlSettings (See

NMI Button Control Settings )

Read-only

Table 242. Chassis System Properties

Name

Object ID

Description

Syntax

Access chassisSystemProperties

1.3.6.1.4.1.674.10892.1.300.10.1.46

Defines the properties of the system.

DellSystemProperties (See

System Properties

)

Read-only

Table 243. Chassis System Revision Number

Name

Object ID

Description

Syntax

Access chassisSystemRevisionNumber

1.3.6.1.4.1.674.10892.1.300.10.1.47

Defines the revision number of the system where zero indicates the original version of the system. The revision number is not available on all systems.

DellUnsigned8BitRange

Read-only

Table 244. Chassis System Revision Name

Name

Object ID

Description

Syntax

Access chassisSystemRevisionName

1.3.6.1.4.1.674.10892.1.300.10.1.48

Defines the revision name of the system, if applicable.

DellString

Read-only

62 Server Administrator Group

Table 245. Chassis Express Service Code Name

Name

Object ID

Description

Syntax

Access chassisExpressServiceCodeName

1.3.6.1.4.1.674.10892.1.300.10.1.49

Defines the express service code of the chassis.

DellString

Read-only

Table 246. Chassis Node ID

Name

Object ID

Description

Syntax

Access chassisNodeIDName

1.3.6.1.4.1.674.10892.1.300.10.1.50

Defines the NodeID of the chassis.

DellString

Read-only

UUID Table

These objects comprise the server administrator definitions for the Universal Unique Identifier (UUID).

Table 247. UUID Table

Name

Object ID

Description

Syntax

Access uUIDTable

1.3.6.1.4.1.674.10892.1.300.20

Defines the UUID table.

SEQUENCE OF UUIDTableEntry

Not accessible

Table 248. UUID Table Entry

Name

Object ID

Description

Syntax

Access

Index uUIDTableEntry

1.3.6.1.4.1.674.10892.1.300.20.1

Defines the UUID table entry.

UUIDTableEntry

Not accessible uUIDIndex

, uUIDchassisIndex

Table 249. UUID Chassis Index

Name

Object ID

Description

Syntax

Access uUIDchassisIndex

1.3.6.1.4.1.674.10892.1.300.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Server Administrator Group 63

Table 250. UUID Index

Name

Object ID

Description

Syntax

Access

Table 251. UUID Type

Name

Object ID

Description

Syntax

Access

Table 252. UUID Value

Name

Object ID

Description

Syntax

Access uUIDIndex

1.3.6.1.4.1.674.10892.1.300.20.1.2

Defines the index of the UUID in a specified chassis.

DellObjectRange

Read-only uUIDType

1.3.6.1.4.1.674.10892.1.300.20.1.3

Defines the type of the UUID for this chassis.

DellUUIDType

Read-only uUIDValue

1.3.6.1.4.1.674.10892.1.300.20.1.4

Defines the value of the UUID for this chassis.

Octet String (SIZE(16))

Read-only

POST Log Table

This section defines attributes for the power-on self-test (POST) log. When you turn on your computer, the POST checks various system components before the operating system loads. The POST tests the random-access memory (RAM), the hard drives, and the keyboard, for example. While the POST is running, it makes a log file that system administrators can view. The variables in this section also contribute to managing the POST log.

Table 253. POST Log Table

Name

Object ID

Description

Syntax

Access postLogTable

1.3.6.1.4.1.674.10892.1.300.30

Defines the POST Log Table.

SEQUENCE OF PostLogTableEntry

Not accessible

Table 254. POST Log Table Entry

Name postLogTableEntry

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.300.30.1

Defines the POST Log Table entry.

PostLogTableEntry

Not accessible postLogchassisIndex

64 Server Administrator Group

Table 254. POST Log Table Entry (continued)

, postLogRecordIndex

Table 255. POST Log Chassis Index

Name postLogchassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.300.30.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 256. POST Log Record Index

Name

Object ID

Description

Syntax

Access postLogRecordIndex

1.3.6.1.4.1.674.10892.1.300.30.1.2

Defines the record number (one-based) of the POST log.

DellUnsigned32BitRange

Read-only

Table 257. POST Log State Capabilities Unique

Name

Object ID

Description

Syntax

Access postLogStateCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.300.30.1.3

Defines the capabilities of the object that is writing the POST log.

DellStateCapabilitiesLogUnique

Read-only

Table 258. POST Log State Settings Unique

Name

Object ID

Description

Syntax

Access postLogStateSettingsUnique

1.3.6.1.4.1.674.10892.1.300.30.1.4

Defines the state of the object that is writing the POST log.

DellStateSettingsLogUnique

Read-only

Table 259. POST Log Record

Name

Object ID

Description

Syntax

Access

Table 260. POST Log Format

Name

Object ID postLogRecord

1.3.6.1.4.1.674.10892.1.300.30.1.5

Defines the data for the specified chassis and record index in the POST log being returned.

DisplayString (SIZE (0..1024))

Read-only postLogFormat

1.3.6.1.4.1.674.10892.1.300.30.1.5

Server Administrator Group 65

Table 260. POST Log Format (continued)

Description

Syntax

Access

Defines format of the POST log.

DellLogFormat (See

Log Format

)

Read-only

Event Log Table

Table 261. Event Log Table

Name

Object ID

Description

Syntax

Access eventLogTableEntry

1.3.6.1.4.1.674.10892.1.300.40

Defines the Event Log Table.

SEQUENCE OF EventLogTableEntry

Not accessible

Table 262. Event Log Table Entry

Name eventLogTableEntry

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.300.40.1

Defines the event Log Table Entry.

EventLogTableEntry

Not accessible eventLogchassisIndex

, eventLogRecordIndex

Table 263. Event Log Chassis Index

Name

Object ID

Description

Syntax

Access eventLogchassisIndex

1.3.6.1.4.1.674.10892.1.300.40.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 264. Event Log Record Index

Name eventLogRecordIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.300.40.1.2

Defines the record index of the event log.

DellUnsigned32BitRange

Read-only

Table 265. Event Log State Capabilities Unique

Name

Object ID eventLogStateCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.300.40.1.3

66 Server Administrator Group

Table 265. Event Log State Capabilities Unique (continued)

Description

Syntax

Access

Defines the capabilities of the object that is writing the event log.

DellStateCapabilitiesLogUnique

Read-only

Table 266. Event Log State Settings Unique

Name

Object ID

Description

Syntax

Access eventLogStateSettingsUnique

1.3.6.1.4.1.674.10892.1.300.40.1.4

Defines the state settings for the object that is writing the event log.

DellStateSettingsLogUnique

Read-only

Table 267. Event Log Record

Name

Object ID

Description

Syntax

Access eventLogRecord

1.3.6.1.4.1.674.10892.1.300.40.1.5

Defines the data for the specified chassis and log record index in the event log being returned.

DisplayString

Read-only

Table 268. Event Log Format

Name

Object ID

Description

Syntax

Access eventLogFormat

1.3.6.1.4.1.674.10892.1.300.40.1.6

Defines the format of the event log.

DellLogFormat (See

Log Format

)

Read-only

Table 269. Event Log Severity Status

Name

Object ID

Description

Syntax

Access

Status eventLogSeverityStatus

1.3.6.1.4.1.674.10892.1.300.40.1.7

Defines the severity of the event log record.

DellStatus

Read-only

Mandatory

Table 270. Event Log Date Name

Name

Object ID

Description

Syntax

Access

Status eventLogDateName

1.3.6.1.4.1.674.10892.1.300.40.1.8

Defines the date and time of the event log record.

DellDateName

Read-only

Mandatory

Server Administrator Group 67

System BIOS Table

This table lists objects that define the system’s basic input/output system (BIOS).

Table 271. System BIOS Table

Name

Object ID

Description

Syntax

Access systemBIOSTable

1.3.6.1.4.1.674.10892.1.300.50

Defines the System BIOS Table.

SEQUENCE OF SystemBIOSTableEntry

Not accessible

Table 272. System BIOS Table Entry

Name

Object ID

Description

Syntax

Access

Index systemBIOSTableEntry

1.3.6.1.4.1.674.10892.1.300.50.1

Defines the System BIOS Table entry.

SystemBIOSTableEntry

Not accessible systemBIOSchassisIndex

, systemBIOSIndex

Table 273. System BIOS Chassis Index

Name

Object ID

Description

Syntax

Access systemBIOSchassisIndex

1.3.6.1.4.1.674.10892.1.300.50.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 274. System BIOS Index

Name

Object ID

Description

Syntax

Access systemBIOSIndex

1.3.6.1.4.1.674.10892.1.300.50.1.2

Defines the index (one-based) of the system BIOS of this object.

DellObjectRange

Read-only

Table 275. System BIOS State Capabilities

Name

Object ID

Description

Syntax

Access systemBIOSStateCapabilities

1.3.6.1.4.1.674.10892.1.300.50.1.3

Defines the capabilities of the system BIOS of this object.

DellStateCapabilities

Read-only

68 Server Administrator Group

Table 276. System BIOS State Settings

Name

Object ID

Description

Syntax

Access systemBIOSStateSettings

1.3.6.1.4.1.674.10892.1.300.50.1.4

Defines the state of the system BIOS of this object.

DellStateSettings

Read-only

Table 277. System BIOS Status

Name

Object ID

Description

Syntax

Access systemBIOSStatus

1.3.6.1.4.1.674.10892.1.300.50.1.5

Defines the status of the system BIOS of this object.

DellStatus

Read-only

Table 278. System BIOS Size

Name

Object ID

Description

Syntax

Access systemBIOSSize

1.3.6.1.4.1.674.10892.1.300.50.1.6

Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown.

DellUnsigned32BitRange

Read-only

Table 279. System BIOS Release Date Name

Name systemBIOSReleaseDateName

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.300.50.1.7

Defines the release date of the system BIOS.

DellDateName

Read-only

Table 280. System BIOS Version Name

Name

Object ID

Description

Syntax

Access systemBIOSVersionName

1.3.6.1.4.1.674.10892.1.300.50.1.8

Defines the version name of the system BIOS.

DellString

Read-only

Table 281. System BIOS Starting Address

Name

Object ID

Description

Syntax

Access systemBIOSStartingAddress

1.3.6.1.4.1.674.10892.1.300.50.1.9

Defines the starting address of the system BIOS. A zero (0) indicates that the address is unknown.

DellUnsigned64BitRange

Read-only

Server Administrator Group 69

Table 282. System BIOS Ending Address

Name

Object ID

Description

Syntax

Access systemBIOSEndingAddress

1.3.6.1.4.1.674.10892.1.300.50.1.10

Defines the ending address of the system BIOS. A zero (0) indicates that the address is unknown.

DellUnsigned64BitRange

Read-only

Table 283. System BIOS Manufacturer Name

Name

Object ID

Description

Syntax

Access systemBIOSManufacturerName

1.3.6.1.4.1.674.10892.1.300.50.1.11

Defines the system BIOS manufacturer’s name.

DellString

Read-only

Table 284. System BIOS Characteristics

Name

Object ID

Description systemBIOSCharacteristics

1.3.6.1.4.1.674.10892.1.300.50.1.12

Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit 63 is the first bit in the value, and bit 0 is the last bit in the value. See the description of DellUnsigned64BitRange at the beginning of this file for more information on the format of the value.

Bits 48-63 need to be examined in the context of the system ID. The system ID is available in the attribute chassisID. If the value for chassisID is non-zero, bits 48-63 have the meaning defined below

● Bit 0 - Reserved

● Bit 1 - Reserved

● Bit 2 - Unknown

● Bit 3 - BIOS Characteristics Not Supported

● Bit 4 - ISA is supported

● Bit 5 - MCA is supported

● Bit 6 - EISA is supported

● Bit 7 - PCI is supported

● Bit 8 - PC Card (PCMCIA) is supported

● Bit 9 - Plug and Play is supported

● Bit 10 - APM is supported

● Bit 11 - BIOS is Upgradeable (Flash)

● Bit 12 - BIOS shadowing is allowed

● Bit 13 - VL-VESA is supported

● Bit 14 - ESCD support is available

● Bit 15 - Boot from CD is supported

● Bit 16 - Selectable Boot is supported

● Bit 17 - BIOS ROM is socketed

● Bit 18 - Boot From PC Card (PCMCIA) is supported

● Bit 19 - EDD (Enhanced Disk Drive) Specification is supported

● Bit 20 - Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360

RPM) is supported

● Bit 21 - Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in, 360 RPM) is supported

● Bit 22 - Int 13h - 5.25 in / 360 KB Floppy Services are supported

● Bit 23 - Int 13h - 5.25 in /1.2MB Floppy Services are supported

70 Server Administrator Group

Table 284. System BIOS Characteristics (continued)

Syntax

● Bit 24 - Int 13h - 3.5 in / 720 KB Floppy Services are supported

● Bit 25 - Int 13h - 3.5 in / 2.88 MB Floppy Services are supported

● Bit 26 - Int 5h, Print Screen Service is supported

● Bit 27 - Int 9h, 8042 Keyboard services are supported

● Bit 28 - Int 14h, Serial Services are supported

● Bit 29 - Int 17h, Printer Services are supported

● Bit 30 - Int 10h, CGA/Mono Video Services are supported

● Bit 31 - NEC PC-98

● Bit 32 - -47Reserved

● Bit 48 - Built-in NIC supports Magic Packet

● Bit 49 - System supports Wake-on-LAN

● Bit 50 - System supports chassis intrusion

● Bit 51 - Built-in NIC supports pattern-matching

● Bit 52 - System BIOS supports a 7-character service tag

● Bit 53 - -63 Reserved

DellUnsigned64BitRange

Table 285. System BIOS Characteristics Ext 1

Name

Object ID

Description systemBIOSCharacteristicsExt1

1.3.6.1.4.1.674.10892.1.300.50.1.13

Defines additional characteristics of the system basic input/output system (BIOS). This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).

● Bit 0 - ACPI supported

● Bit 1 - USB Legacy is supported

● Bit 2 - AGP is supported

● Bit 3 - I2O boot is supported

● Bit 4 - LS-120 boot is supported

● Bit 5 - ATAPI ZIP Drive boot is supported

● Bit 6 - 1394 boot is supported

● Bit 7 - Smart Battery supported

Syntax

Access

DellUnsigned8BitRange

Read-only

Table 286. System BIOS Characteristics Ext 2

Name

Object ID

Description

Syntax

Access systemBIOSCharacteristicsExt2

1.3.6.1.4.1.674.10892.1.300.50.1.14

Defines additional characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).

● Bit 0 - BIOS Boot Specification supported

● Bit 1 - Function key-initiated Network Service boot supported

● Bit 2 - Targeted Content Distribution supported

● Bit 3 - 7Reserved

DellUnsigned8BitRange

Read-only

Server Administrator Group 71

Firmware Table

Table 287. Firmware Table

Name

Object ID

Description

Syntax

Access firmwareTable

1.3.6.1.4.1.674.10892.1.300.60

Defines the Firmware Table.

SEQUENCE OF FirmwareTableEntry

Not accessible

Table 288. Firmware Table Entry

Name

Object ID

Description

Syntax

Access

Index firmwareTableEntry

1.3.6.1.4.1.674.10892.1.300.60.1

Defines the Firmware Table entry

FirmwareTableEntry

Not accessible firmwarechassisIndex

, firmwareIndex

Table 289. Firmware Chassis Index

Name

Object ID

Description

Syntax

Access firmwarechassisIndex

1.3.6.1.4.1.674.10892.1.300.60.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 290. Firmware Index

Name

Object ID

Description

Syntax

Access firmwareIndex

1.3.6.1.4.1.674.10892.1.300.60.1.2

Defines the index (one-based) of the firmware in this chassis.

DellObjectRange

Read-only

Table 291. Firmware State Capabilities

Name

Object ID

Description

Syntax

Access firmwareStateCapabilities

1.3.6.1.4.1.674.10892.1.300.60.1.3

Defines the capabilities of the firmware states.

DellStateCapabilities

Read-only

72 Server Administrator Group

Table 292. Firmware State Capabilities

Name

Object ID

Description

Syntax

Access firmwareStateCapabilities

1.3.6.1.4.1.674.10892.1.300.60.1.4

Defines the state of the firmware and allows for the setting of the firmware.

DellStateCapabilities

Read-only

Table 293. Firmware Status

Name

Object ID

Description

Syntax

Access

Table 294. Firmware Size

Name

Object ID

Description firmwareStatus

1.3.6.1.4.1.674.10892.1.300.60.1.5

Defines the status of the firmware.

DellStateSettings

Read-only firmwareSize

1.3.6.1.4.1.674.10892.1.300.60.1.6

Defines the image size of the firmware in KB. A zero (0) indicates that the size is unknown.

DellUnsigned16BitRange

Read-only

Syntax

Access

Table 295. Firmware Type

Name

Object ID

Description

Syntax

Access firmwareType

1.3.6.1.4.1.674.10892.1.300.60.1.7

Defines the type of the firmware.

DellFirmwareType

Read-only

Table 296. Firmware Type Name

Name

Object ID

Description

Syntax

Access firmwareTypeName

1.3.6.1.4.1.674.10892.1.300.60.1.8

Defines the name of firmware type.

DellString

Read-only

Table 297. Firmware Update Capabilities

Name

Object ID

Description

Syntax

Access firmwareUpdateCapabilities

1.3.6.1.4.1.674.10892.1.300.60.1.9

Defines the bitmap of supported methods for firmware update.

DellUnsigned16BitRange

Read-only

Server Administrator Group 73

Table 298. Firmware Date Name

Name

Object ID

Description

Syntax

Access firmwareDateName

1.3.6.1.4.1.674.10892.1.300.60.1.10

Defines the date of the firmware.

DellDateName

Read-only

Table 299. Firmware Version Name

Name

Object ID

Description

Syntax

Access firmwareVersionName

1.3.6.1.4.1.674.10892.1.300.60.1.11

Defines the version name of the firmware.

DellString

Read-only

Intrusion Table

The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of a computer is removed.

NOTE: The Drive Bay sensor is available on Dell PowerEdge R740xd2 systems only.

Table 300. Intrusion Table

Name

Object ID

Description

Syntax

Access intrusionTable

1.3.6.1.4.1.674.10892.1.300.70

Defines the Intrusion Table.

SEQUENCE OF IntrusionTableEntry

Not accessible

Table 301. Intrusion Table Entry

Name

Object ID

Description

Syntax

Access

Index intrusionTableEntry

1.3.6.1.4.1.674.10892.1.300.70.1

Defines the Intrusion Table entry.

IntrusionTableEntry

Not accessible intrusionchassisIndex

, intrusionIndex

Table 302. Intrusion Chassis Index

Name

Object ID

Description intrusionchassisIndex

1.3.6.1.4.1.674.10892.1.300.70.1.1

Defines the index (one-based) of this chassis.

74 Server Administrator Group

Table 302. Intrusion Chassis Index (continued)

Syntax

Access

DellObjectRange

Read-only

Table 303. Intrusion Index

Name

Object ID

Description

Syntax

Access intrusionIndex

1.3.6.1.4.1.674.10892.1.300.70.1.2

Defines the index of the intrusion objects and drive bay object in this subgroup.

DellObjectRange

Read-only

Table 304. Intrusion State Capabilities

Name

Object ID

Description

Syntax

Access intrusionStateCapabilities

1.3.6.1.4.1.674.10892.1.300.70.1.3

Defines the capabilities of the intrusion object and drive bay object.

DellStateCapabilities

Read-only

Table 305. Intrusion State Settings

Name

Object ID

Description

Syntax

Access intrusionStateSettings

1.3.6.1.4.1.674.10892.1.300.70.1.4

Defines the settings of the intrusion object and drive bay object.

DellStateSettings

Read-only

Table 306. Intrusion Status

Name

Object ID

Description

Syntax

Access

Table 307. Intrusion Reading

Name

Object ID

Description

Syntax

Access

Table 308. Intrusion Type

Name

Object ID

Description intrusionStatus

1.3.6.1.4.1.674.10892.1.300.70.1.5

Defines the status of the intrusion object and drive bay object.

DellStatus

Read-only intrusionReading

1.3.6.1.4.1.674.10892.1.300.70.1.6

Defines the reading of the intrusion object and drive bay object.

DellIntrusionReading

Read-only intrusionType

1.3.6.1.4.1.674.10892.1.300.70.1.7

Defines the type of the intrusion object and drive bay object.

Server Administrator Group 75

Table 308. Intrusion Type (continued)

Syntax

Access

DellIntrusionType

Read-only

Table 309. Intrusion Location Name

Name

Object ID

Description

Syntax

Access intrusionLocationName

1.3.6.1.4.1.674.10892.1.300.70.1.8

This attribute defines the location of the intrusion and drive bay sensor.

DellString

Read-only

Baseboard Table

This table lists objects that define the baseboard of a system.

Table 310. Baseboard Table

Name

Object ID

Description

Syntax

Access baseBoardTable

1.3.6.1.4.1.674.10892.1.300.80

Defines the Baseboard Table.

SEQUENCE OF BaseBoardTableEntry

Not accessible

Table 311. Baseboard Table Entry

Name

Object ID

Description

Syntax

Access

Index baseBoardTableEntry

1.3.6.1.4.1.674.10892.1.300.80.1

Defines the Baseboard Table entry.

BaseBoardTableEntry

Not accessible baseBoardChassisIndex

, baseBoardIndex

Table 312. Baseboard Chassis Index

Name baseBoardchassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.300.80.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 313. Baseboard Index

Name

Object ID baseBoardIndex

1.3.6.1.4.1.674.10892.1.300.80.1.2

76 Server Administrator Group

Table 313. Baseboard Index (continued)

Description

Syntax

Access

Defines the index (one-based) of the base board.

DellObjectRange

Read-only

Table 314. Baseboard State Capabilities

Name

Object ID

Description

Syntax

Access baseBoardStateCapabilities

1.3.6.1.4.1.674.10892.1.300.80.1.3

Defines the state capabilities of the baseboard.

DellStateCapabilities

Read-only

Table 315. Baseboard State Settings

Name

Object ID

Description

Syntax

Access baseBoardStateSettings

1.3.6.1.4.1.674.10892.1.300.80.1.4

Defines the state settings of the baseboard.

DellStateSettings

Read-only

Table 316. Baseboard Status

Name

Object ID

Description

Syntax

Access baseBoardStatus

1.3.6.1.4.1.674.10892.1.300.80.1.5

Defines the status of the baseboard.

DellStatus

Read-only

Table 317. Baseboard Feature Flags

Name

Object ID

Description

Syntax

Access baseBoardFeatureFlags

1.3.6.1.4.1.674.10892.1.300.80.1.6

Defines the features of the baseboard..

DellBaseBoardFeatureFlags

Read-only

Table 318. Baseboard Type

Name

Object ID

Description

Syntax

Access baseBoardType

1.3.6.1.4.1.674.10892.1.300.80.1.7

Defines the type of the baseboard.

DellBaseBoardType

Read-only

Table 319. Baseboard Type Name

Name

Object ID baseBoardTypeName

1.3.6.1.4.1.674.10892.1.300.80.1.8

Server Administrator Group 77

Table 319. Baseboard Type Name (continued)

Description

Syntax

Access

Defines the name of the type of baseboard.

DellString

Read-only

Table 320. Baseboard Location Name

Name

Object ID

Description

Syntax

Access baseBoardLocationName

1.3.6.1.4.1.674.10892.1.300.80.1.9

Defines the location name of the baseboard.

DellString

Read-only

Table 321. Baseboard Manufacturer Name

Name

Object ID

Description

Syntax

Access baseBoardManufacturerName

1.3.6.1.4.1.674.10892.1.300.80.1.10

Defines the baseboard manufacturer’s name.

DellString

Read-only

Table 322. Baseboard Product Name

Name

Object ID

Description

Syntax

Access baseBoardProductName

1.3.6.1.4.1.674.10892.1.300.80.1.11

Defines the baseboard product’s name.

DellString

Read-only

Table 323. Baseboard Version Name

Name

Object ID

Description

Syntax

Access baseBoardVersionName

1.3.6.1.4.1.674.10892.1.300.80.1.12

Defines the baseboard version name..

DellString

Read-only

Table 324. Baseboard Service Tag Name

Name

Object ID

Description

Syntax

Access baseBoardServiceTagName

1.3.6.1.4.1.674.10892.1.300.80.1.13

Defines the baseboard service tag name.

DellString

Read-only

Table 325. Baseboard Piece Part ID (PPID) Name

Name

Object ID baseBoardPiecePartIDName

1.3.6.1.4.1.674.10892.1.300.80.1.14

78 Server Administrator Group

Table 325. Baseboard Piece Part ID (PPID) Name (continued)

Description

Syntax

Access

Defines the baseboard PPID.

DellString

Read-only

Table 326. Baseboard Asset Tag Name

Name

Object ID

Description

Syntax

Access baseBoardAssetTagName

1.3.6.1.4.1.674.10892.1.300.80.1.15

Defines the baseboard asset tag name.

DellString

Read-only

Table 327. Baseboard Express Service Code Name

Name

Object ID

Description

Syntax

Access baseBoardExpressServiceCodeName

1.3.6.1.4.1.674.10892.1.300.80.1.16

Defines the express service code of the baseboard.

DellString

Read-only

Chassis Information Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 328. Log Format

Variable Name : DellLogFormat

Data Type: Integer

Possible Data Values raw(1) ascii(2) uniCode(3)

Meaning of Data Value

The log is in the format received from the firmware.

The log is in ASCII format.

The log is in Unicode format.

Table 329. Chassis Type

Variable Name : DellChassisType

Data Type: Integer

Possible Data Values other(1) unknown(2) desktop(3)

Meaning of Data Value

The chassis type is not one of the following:

The chassis type is unknown.

The chassis type is a desktop.

lowProfileDesktop(4

)

The chassis type is a low-profile desktop.

pizzaBox(5) miniTower(6)

The chassis type is a pizza box.

The chassis type is a minitower.

Server Administrator Group 79

Table 329. Chassis Type (continued) tower(7) portable(8)

The chassis type is a tower.

The chassis type is a portable.

lapTop(9) noteBook(10) handHeld(11)

The chassis type is a laptop.

The chassis type is a notebook.

The chassis type is a handheld.

dockingStation(12) The chassis type is a docking station.

allInOne(13) subNoteBook(14) spaceSaving(15)

The chassis type is an all-in-one.

The chassis type is a subnotebook.

The chassis type is a spacesaver.

lunchBox(16) mainSystemChassis(1

7) expansionChassis(18

) subChassis(19)

The chassis type is a lunch box.

The chassis type is the main system chassis.

The chassis type is an expansion chassis.

busExpansionChassis

(20) peripheralChassis(2

1)

The chassis type is a subchassis.

The chassis type is a bus-expansion chassis.

The chassis type is a peripheral chassis.

raidChassis(22) rackMountChassis(23

) sealedCasePC(24) multiSystemChassis(

25)

The chassis type is a disk RAID chassis.

The chassis type is a rack-mounted chassis.

The chassis type is a sealed-case chassis.

The chassis type is a multisystem chassis.

Table 330. Connection Status

Variable Name : DellConnectionStatus

Data Type: Integer

Possible Data Values unknown(2) ok(3) failure(4)

Meaning of Data Value

The status of the chassis connection is unknown.

The status of the chassis connection is OK.

The status of the chassis connection is failure.

Table 331. Fan Control Capabilities

Variable Name : DellFanControlCapabilities

Data Type: Integer

Possible Data Values unknown(1)

Meaning of Data Value

The fan’s capabilities are unknown.

lowSpeedCapable(2) The fan can be set to low speed.

highSpeedCapable(4) The fan can be set to high speed.

80 Server Administrator Group

Table 331. Fan Control Capabilities (continued) lowOrhighSpeedCapab le(6)

The fan can be set to low or high speed.

Table 332. Front-Panel LED Control Capabilities

Variable Name : DellLEDControlCapabilities

Data Type: Integer

Possible Data Values unknown(1)

Meaning of Data Value

The LED control capabilities are unknown.

alertOnErrorCapable

(2)

The LED control can be set to alert on an error condition.

alertOnWarningAndEr rorCap able(4)

The LED control can be set to alert on an error and a warning condition.

alertOnWarningOrErr orCapa ble(6)

The LED control can be set to alert on an error or a warning condition.

Table 333. Front-Panel LED Control Settings

Variable Name : DellLEDControlSettings

Data Type: Integer

Possible Data Values unknown(1) alertOnError(2) alertOnWarningAndE rror(4)

Meaning of Data Value

The LED control setting is unknown.

The LED control is set to alert on an error condition.

The LED control is set to alert on an error or a warning condition.

Table 334. Hard-Drive Fault LED Control Capabilities

Variable Name : DellHDFaultLEDControlCapabilities

Data Type: Integer

Possible Data Values none(0)

Meaning of Data Value

The hard drive has no fault LED capabilities.

unknownCapabilitie s(1) enableCapable(2)

The hard-drive fault LED capabilities are unknown.

The hard-drive fault LED can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).

notReadyCapable(4) The hard-drive fault LED can indicate not ready.

resetCapable(8) The hard-drive fault LED can be reset.

Table 335. Hard-Drive Fault LED Control Settings

Variable Name : DellHDFaultLEDControlSettings

Data Type: Integer

Possible Data Values none(0) unknown(1)

Meaning of Data Value

The LEDs do not have any fault settings capabilities.

The hard-drive fault LEDs’ state is unknown.

Server Administrator Group 81

Table 335. Hard-Drive Fault LED Control Settings (continued) enabled(2) The hard-drive fault LEDs’ state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).

The hard-drive fault LEDs’ state is not ready.

notReady(4) reset(8) The hard-drive fault LEDs have been reset.

resetAndEnable(10) The hard-drive fault LEDs have been reset and enabled.

Table 336. Chassis Identification Control Capabilities

Variable Name : DellChassisIdentifyControlCapabilities

Data Type: Integer

Possible Data Values none(0) unknownCapabilitie s(1)

Meaning of Data Value

The LEDs do not have any chassis identification capabilities.

The chassis identification control’s capabilities are unknown.

enableCapable(2) The chassis identification controls can be disabled

(offline, a binary 0 value) or enabled (online, a binary

1 value).

notReadyCapable(4) The chassis identification control’s capabilities are not ready.

identifyCapable(8) The chassis identification control’s LEDs can be made to identify the chassis.

resetAndEnable(10) The hard-drive fault LEDs have been reset and enabled.

NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning components. When enabled, the blinking lights help administrators locate the problem chassis.

Table 337. Chassis Identification Control Settings

Variable Name : DellChassisIdentifyControlSettings

Data Type: Integer

Possible Data Values Meaning of Data Value unknown(1) enabled(2)

The chassis identification control’s state is unknown..

The chassis identification control’s state is disabled

(offline, a binary 0 value) or enabled (online, a binary

1 value).

The chassis identification control’s state is not ready.

notReady(4) identifyChassis(8) The chassis identification control’s LEDs may be returned to (normal) 0, or (identify chassis) 1.

identifyChassisAnd

Enable (10)

The chassis identification control’s LEDs may be returned to normal (a binary 0 value), or identify chassis and enabled (a binary 1 value).

Table 338. Host Control Capabilities

Variable Name : DellHostControlCapabilities

NOTE: An operator can manually enable these actions using SNMP.

82 Server Administrator Group

Table 338. Host Control Capabilities (continued)

Data Type: Integer

Possible Data Values manualRebootCapabl e(1) manualPowerOFFCapa ble(2) manualPowerCycleCa pable(4) manualAllExceptOpe rating

SystemShutdownCapa ble(7) manualOperatingSys temShut downCapable(8) manualFullyCapable

(15)

Meaning of Data Value

The operator can reboot capable host.

The operator can power off capable host.

The operator can power-cycle capable host.

The operator can reboot and power off capable host.

The operator can shut down the operating-system– shutdown capable host.

The operator can reboot, power on and off the powercycle capable host, and shut down the operatingsystem–shutdown capable host.

The operator can reboot with operating system shutdown.

manualRebootWithOS

Shutdow nCapable(16) manualRebootWithou tOSShut downCapable(32) manualPowerOffWith

OSShutd ownCapable(64) manualPowerOffWith outOSSh utdownCapable(128) manualPowerCycleWi thOSShu tdownCapable(256) manualPowerCycleWi thoutOS

ShutdownCapable(51

2)

The operator can reboot without operating system shutdown.

The operator can power off with operating system shutdown.

The operator can power off without operating system shutdown.

The operator can power cycle with operating system shutdown.

The operator can power cycle without operating system shutdown.

Table 339. Host Control Settings

Variable Name : DellHostControlSettings

NOTE: An operator can manually cause these actions using SNMP.

Data Type: Integer

Possible Data Values manualReboot(1) manualPowerOFF(2) manualPowerCycle(4

)

Meaning of Data Value

The operator can reboot the host.

The operator can power off the host.

Power cycle the host.

Server Administrator Group 83

Table 339. Host Control Settings (continued) manualOperatingSys temShutdown(8) manualOperatingSys temShutdownThe nPowerCycle(12)

The operator can shut down the operating system on the host.

The operator can shut down the operating system on the host then power cycle machine.

Table 340. Watchdog Control Capabilities

Variable Name : DellWatchDogControlCapabilities

NOTE: When the system determines that the operating system is not responding, it automatically performs the selected action without operator intervention.

Data Type: Integer

Possible Data Values automaticRebootCap able(1) automaticPowerCycl eCapable(2) automaticNotificat ionCapable(4) automaticWatchDogT imerCapable(8) automaticPowerOffC apable(16) automaticAllExcept

NotificationCap able(27) automaticFullyCapa ble(31)

Meaning of Data Value

Watchdog controls can be set to reboot capable host.

Watchdog controls can be set to power cycleable capable host.

Watchdog controls can be set to notify capable host

Watchdog controls can be set to function automatically.

Watchdog controls can be set to automatically power off host.

Watchdog controls can be set to automatically perform all functions except notification capable.

Watchdog controls can be set to automatically perform all functions.

Table 341. Watchdog Control Settings

Variable Name : DellWatchControlSettings

NOTE: The watchdog timer is the mechanism used by a chassis to determine if the operating system has stopped responding.

Data Type: Integer

Meaning of Data Value

Automatic reboot is enabled for this host.

Possible Data Values automaticRebootEna bled(1) automaticPowerCycl eEnabled(2) automaticNotificat ionEnabled(4) automaticPowerOffE nabled(8)

Automatic power cycleable is enabled for this host.

Automatic notification is enabled for this host.

Automatic power off is enabled for this host.

Table 342. Watchdog Timer Capabilities

Variable Name : DellWatchDogTimerCapabilities

84 Server Administrator Group

Table 342. Watchdog Timer Capabilities (continued)

Data Type: Integer

Possible Data Values type1Capable(1) type2Capable(2) type3Capable(4)

Meaning of Data Value

Watchdog timer can time in intervals from 20–480 seconds.

Watchdog timer can time in 30-, 60-, 120-, and 480second intervals.

Watchdog timer can time in 60-second intervals.

Table 343. Power Button Control Capabilities

Variable Name : DellPowerButtonControlCapabilities

Data Type: Integer

Possible Data Values none(0) unknownCapabilitie s(1) enableCapable(2)

Meaning of Data Value

The power button has no capabilities.

The power button capabilities are unknown.

The power button can be enabled (online) or disabled

(offline).

Table 344. Power Button Control Settings

Variable Name : DellPowerButtonControlSettings

Data Type: Integer

Possible Data Values none(0) unknown(1) enabled(2) disabled(4)

Meaning of Data Value

The power button has no settings capabilities.

The power button settings are unknown.

The power button state is enabled.

The power button state is disabled.

Table 345. NMI Button Control Capabilities

Variable Name : DellNMIButtonControlCapabilities

Data Type: Integer

Possible Data Values none(0) unknownCapabilitie s(1) enableCapable(2)

Meaning of Data Value

The NMI button has no capabilities.

The NMI button capabilities are unknown.

The NMI button can be enabled (online) or disabled

(offline).

Table 346. System Properties

Variable Name : DellSystemProperties

NOTE: These values are bit masks, so combination values are possible.

Data Type: Integer

Possible Data Values Meaning of Data Value

Server Administrator Group 85

Table 346. System Properties (continued) none(0) energySmart(1)

No properties.

The system is an Energy Smart System.

Table 347. NMI Button Control Settings

Variable Name : DellNMIButtonControlSettings

Data Type: Integer

Possible Data Values none(0) unknown(1) enabled(2) disabled(4)

Meaning of Data Value

The NMI button has no settings capabilities.

The NMI button settings are unknown.

The NMI button state is enabled.

The NMI button state is disabled.

Table 348. Baseboard Type

Variable Name : DellBaseBoardType

Data Type: Integer

Possible Data Values unknown(1) other(2) serverBlade(3)

Meaning of Data Value

The baseboard type is unknown.

The baseboard type is not one of the following types.

The baseboard type is a server blade.

connectivitySwitch

(4) systemManagementMo dule(5)

The baseboard type is a connectivity switch.

The baseboard type is a system management module.

processorModule(6) The baseboard type is a processor module.

ioModule(7) memoryModule(8) daughterBoard(9)

The baseboard type is an I/O module.

The baseboard type is a memory module

The baseboard type is a daughter board.

The baseboard type is a mother board.

The baseboard type is a processor or memory module motherboard(10) processorMemoryMod ule(11) processorIOModule(

12) interconnectBoard(

13)

The baseboard type is a processor or I/O module

The baseboard type is an interconnect board.

Table 349. Chassis System Class

Variable Name : DellChassisSystemClass

Data Type: Integer

Possible Data Values other(1) unknown(2)

Meaning of Data Value

The chassis system class is not one of the following:

The chassis system class is unknown.

86 Server Administrator Group

Table 349. Chassis System Class (continued) workstationClass(3

) serverClass(4) desktopClass(5) portableClass(6) netPCClass(7) storageClass(8)

The chassis system class is a workstation.

The chassis system class is a server.

The chassis system class is a desktop.

The chassis system class is a portable.

The chassis system class is a Net PC.

The chassis system class is storage.

Table 350. Firmware Type

Variable Name : DellFirmwareType

Data Type: Integer

Possible Data Values other(1) unknown(2) systemBIOS(3) embeddedSystemMana gementContro ller(4) powerSupplyParalle lingBoard(5)

Meaning of Data Value

The firmware type is other than following values.

The firmware type is unknown.

The firmware type is System BIOS

The firmware type is Embedded System Management

Controller.

The firmware type is Power Supply Paralleling Board.

systemBackPlane(6) The firmware type is System (Primary) Backplane.

powerVault2XXSKern el(7) powerVault2XXSAppl ication(8) frontPanel(9)

The firmware type is Dell PowerVault 2XXS Kernel.

The firmware type is PowerVault 2XXS Application.

The firmware type is Front Panel Controller.

baseboardManagemen tController (10) hotPlugPCI(11)

The firmware type is Baseboard Management

Controller.

The firmware type is Hot Plug Peripheral Component

Interconnect (PCI) Controller.

The firmware type is Sensor Data Records.

sensorData(12) peripheralBay(13) secondaryBackPlane

(14) secondaryBackPlane

ESM3And4(15) rac(16) iDRAC(17)

The firmware type is Peripheral Bay Backplane.

The firmware type is Secondary Backplane for ESM 2 systems.

The firmware type is Secondary Backplane for ESM 3 and 4 systems.

The firmware type is Remote Access Controller.

The firmware type is Integrated Dell Remote Access

Controller.

The firmware type is Unified Server Configurator.

unifiedServerConfi gurator(19) lifecycleControlle r(20)

The firmware type is Lifecycle Controller.

Server Administrator Group 87

Table 350. Firmware Type (continued) iDRAC7(21) iDRAC8(22) iDRAC9(23)

The firmware type is Integrated Dell Remote Access

Controller 7.

The firmware type is Integrated Dell Remote Access

Controller 8.

The firmware type is Integrated Dell Remote Access

Controller 9.

Table 351. Intrusion Reading

Variable Name : DellIntrusionReading

Data Type: Integer

Possible Data Values chassisNotBreached(1) chassisBreached(2) chassisBreachedPrior(3)

Meaning of Data Value

The chassis is not breached and no uncleared breaches.

The chassis is currently breached.

The chassis breached prior to boot and has not been cleared.

The intrusion sensor has failed.

chassisBreachSensorFailure(4

) driveBayOpen(5) driveBayOpenExtended(6)

The drive bay is open.

The drive bay open is extended.

Table 352. Intrusion Type

Variable Name : DellIntrusionType

Data Type: Integer

Possible Data Values chassisBreachDetectionWhenPo werON(1) chassisBreachDetectionWhenPo werOFF(2)

Meaning of Data Value

This type detects the intrusion while power on.

This type detects the intrusion while power off.

Table 353. Baseboard Feature Flags

Variable Name : DellBaseBoardFeatureFlags

Data Type: Integer

Possible Data Values Meaning of Data Value

NOTE: These values are bit fields, so combination values are possible.

no features(0) boardIsHostingBoar d(1) boardRequiresDaugh terBoard (2) boardIsRemovable(4

) boardIsReplaceable

(8)

This baseboard has no feature flags.

This baseboard is a hosting board.

This baseboard requires at least one daughter board or auxiliary card.

This baseboard is removable.

This baseboard is replaceable.

88 Server Administrator Group

Table 353. Baseboard Feature Flags (continued) boardIsHotSwappabl e(16)

This baseboard is hot swappable.

Operating System Group

The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, service pack, and patch level of the installed operating system.

Operating System Memory Table

Table 354. Operating System Memory Table

Name

Object ID

Description

Syntax

Access operatingSystemMemoryTable

1.3.6.1.4.1.674.10892.1.400.20

Defines the Operating System Memory Table.

SEQUENCE OF OperatingSystemMemoryTableEntry

Not accessible

Table 355. Operating System Memory Table Entry

Name

Object ID

Description

Syntax

Access

Index operatingSystemTableEntry

1.3.6.1.4.1.674.10892.1.400.20.1

Defines the Operating System Memory Table entry.

OperatingSystemMemoryTableEntry

Not accessible operatingSystemMemorychassisIndex

Table 356. Operating System Memory Chassis Index

Name

Object ID

Description

Syntax

Access operatingSystemMemorychassisIndex

1.3.6.1.4.1.674.10892.1.400.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 357. Operating System Memory State Capabilities

Name

Object ID

Description

Syntax

Access operatingSystemMemoryStateCapabilities

1.3.6.1.4.1.674.10892.1.400.20.1.2

Defines the capabilities of the operating system memory.

DellStateCapabilities

Read-only

Table 358. Operating System Memory State Settings

Name

Object ID operatingSystemMemoryStateSettings

1.3.6.1.4.1.674.10892.1.400.20.1.3

Server Administrator Group 89

Table 358. Operating System Memory State Settings (continued)

Description

Syntax

Access

Defines the state and allows the setting of the operating system memory.

DellStateSettings

Read-only

Table 359. Operating System Memory Status

Name

Object ID

Description

Syntax

Access operatingSystemMemoryStatus

1.3.6.1.4.1.674.10892.1.400.20.1.4

Defines the status of the operating system memory.

DellStatus

Read-only

Table 360. Operating System Memory Total Physical Size

NOTE: operatingSystemMemoryTotalPhysicalSize is no more used. This attribute is deprecated and replaced by operatingSystemMemoryExtTotalPhysicalSize .

Name

Object ID

Description

Syntax

Access operatingSystemMemoryTotalPhysicalSize

1.3.6.1.4.1.674.10892.1.400.20.1.5

Defines the total physical memory size in kilobytes.

DellUnsigned32BitRange

Read-only

Table 361. Operating System Memory Available Physical Size

Name

Object ID

Description

Syntax

Access operatingSystemMemoryAvailablePhysicalSize

1.3.6.1.4.1.674.10892.1.400.20.1.6

Defines the available physical memory size in kilobytes.

DellUnsigned32BitRange

Read-only

Table 362. Operating System Memory Total Page File Size

Name

Object ID

Description

Syntax

Access operatingSystemMemoryTotalPageFileSize

1.3.6.1.4.1.674.10892.1.400.20.1.7

Defines the total page file memory size in kilobytes.

DellUnsigned32BitRange

Read-only

Table 363. Operating System Memory Available Page File Size

Name

Object ID

Description

Syntax

Access operatingSystemMemoryAvailablePageFileSize

1.3.6.1.4.1.674.10892.1.400.20.1.8

Defines the available page file memory size in kilobytes.

DellUnsigned32BitRange

Read-only

90 Server Administrator Group

Table 364. Operating System Memory Total Virtual Size

Name

Object ID

Description

Syntax

Access operatingSystemMemoryTotalVirtualSize

1.3.6.1.4.1.674.10892.1.400.20.1.9

Defines the total virtual memory size in kilobytes.

DellUnsigned32BitRange

Read-only

Table 365. Operating System Memory Available Virtual Size

Name

Object ID

Description

Syntax

Access operatingSystemMemoryAvailableVirtualSize

1.3.6.1.4.1.674.10892.1.400.20.1.10

Defines the available virtual memory size in kilobytes.

DellUnsigned32BitRange

Read-only

Table 366. Operating System Memory Ext Total Physical Size

NOTE: This attribute replaces operatingSystemMemoryTotalPhysicalSize .

Name

Object ID

Description

Syntax

Access operatingSystemMemoryExtTotalPhysicalSize

1.3.6.1.4.1.674.10892.1.400.20.1.11

This attribute defines the total physical memory for the operating system memory in

KBytes.

DellUnsigned64BitRange

Read-only

System Resource Group

The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes System Resource Group Tables that track variables such as the owner, ports, system memory, interrupts, and direct memory access.

System Resource Group Tables

The following MIB tables define objects for the System Resource Group:

System Resource Map Table

System Resource Owner Table

System Resource Input/Output (I/O) Port Table

System Resource Memory Table

System Resource Interrupt Table

System Resource Direct Memory Access (DMA) Table

System Resource Map Table

Table 367. System Resource Map Table

Name

Object ID

Description systemResourceMapTable

1.3.6.1.4.1.674.10892.1.500.10

Defines the System Resource Map Table.

Server Administrator Group 91

Table 367. System Resource Map Table (continued)

Syntax

Access

SEQUENCE OF SystemResourceMapTableEntry

Not accessible

Table 368. System Resource Map Table Entry

Name

Object ID

Description

Syntax

Access

Index systemResourceMapTableEntry

1.3.6.1.4.1.674.10892.1.500.10.1

Defines the System Resource Map Table entry.

SystemResourceMapTableEntry

Not accessible systemResourceMapchassisIndex

, systemResourceMapIndex

Table 369. System Resource Map Chassis Index

Name

Object ID

Description

Syntax

Access systemResourceMapChassisIndex

1.3.6.1.4.1.674.10892.1.500.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 370. System Resource Map Index

Name

Object ID

Description

Syntax

Access systemResourceMapIndex

1.3.6.1.4.1.674.10892.1.500.10.1.2

Defines the index of system resource maps in this chassis.

DellObjectRange

Read-only

Table 371. System Resource Map State Capabilities

Name

Object ID

Description

Syntax

Access systemResourceMapStateCapabilities

1.3.6.1.4.1.674.10892.1.500.10.1.3

Defines the capabilities of this system map.

DellStateCapabilities

Read-only

Table 372. System Resource Map State Settings

Name

Object ID

Description

Syntax

Access systemResourceMapStateSettings

1.3.6.1.4.1.674.10892.1.500.10.1.4

Defines the state and allows the setting of this system map.

DellStateSettings

Read-only

92 Server Administrator Group

Table 373. System Resource Map Status

Name

Object ID

Description

Syntax

Access systemResourceMapStatus

1.3.6.1.4.1.674.10892.1.500.10.1.5

Defines the status of this system map.

DellStatus

Read-only

Table 374. System Resource Map Type

Name

Object ID

Description

Syntax

Access systemResourceMapType

1.3.6.1.4.1.674.10892.1.500.10.1.6

Defines the type of this system map.

DellSystemResourceMapType (

System Resource Map Type

)

Read-only

System Resource Owner Table

Table 375. System Resource Owner Table

Name

Object ID

Description

Syntax

Access systemResourceOwnerTable

1.3.6.1.4.1.674.10892.1.500.20

Defines the System Resource Owner Table.

SEQUENCE OF SystemResourceOwnerTableEntry

Not accessible

Table 376. System Resource Owner Table Entry

Name systemResourceOwnerTable

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.500.20.1

Defines the System Resource Owner Table entry. Variables in this group reference the

System Resource Map index.

SystemResourceOwnerTableEntry

Not accessible systemResourceOwnerchassisIndex

, systemResourceOwnerIndex

Table 377. System Resource Owner Chassis Index

Name

Object ID

Description

Syntax

Access systemResourceOwnerchassisIndex

1.3.6.1.4.1.674.10892.1.500.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Server Administrator Group 93

Table 378. System Resource Owner Index

Name

Object ID

Description

Syntax

Access systemResourceOwnerIndex

1.3.6.1.4.1.674.10892.1.500.20.1.2

Defines the index of system resource owners for this chassis.

DellObjectRange

Read-only

Table 379. System Resource Owner State Capabilities

Name

Object ID

Description

Syntax

Access systemResourceOwnerStateCapabilities

1.3.6.1.4.1.674.10892.1.500.20.1.3

Defines the capabilities of this system resource owner.

DellStateCapabilities

Read-only

Table 380. System Resource Owner State Settings

Name

Object ID

Description

Syntax

Access systemResourceOwnerStateSettings

1.3.6.1.4.1.674.10892.1.500.20.1.4

Defines the state settings of this system resource owner.

DellStateSettings

Read-only

Table 381. System Resource Owner Status

Name

Object ID

Description

Syntax

Access systemResourceOwnerStatus

1.3.6.1.4.1.674.10892.1.500.20.1.5

Defines the status of this system resource owner.

DellStatus

Read-only

Table 382. System Resource Owner Interface Type

Name

Object ID

Description

Syntax

Access systemResourceOwnerInterfaceType

1.3.6.1.4.1.674.10892.1.500.20.1.6

Defines the interface type for this system resource owner.

DellResourceOwnerInterfaceType (

Resource Owner Interface Type

)

Read-only

Table 383. System Resource Map Index Reference

Name

Object ID

Description

Syntax

Access systemResourceMapIndexReference

1.3.6.1.4.1.674.10892.1.500.20.1.7

Defines the index to the associated system resource map in this chassis.

DellObjectRange

Read-only

94 Server Administrator Group

Table 384. System Resource Owner Description Name

Name

Object ID

Description

Syntax

Access systemResourceOwnerDescriptionName

1.3.6.1.4.1.674.10892.1.500.20.1.8

Defines the description name of the system resource owner.

DellString

Read-only

Table 385. System Resource Owner Interface Instance

Name

Object ID

Description

Syntax

Access systemResourceOwnerInterfaceInstance

1.3.6.1.4.1.674.10892.1.500.20.1.9

Defines the associated system resource owner interface instance in this chassis.

DellObjectRange

Read-only

System Resource Input Output Port Table

Table 386. System Resource Input/Output Port Table

Name

Object ID

Description

Syntax

Access systemResourceIOPortTable

1.3.6.1.4.1.674.10892.1.500.30

Defines the System Resource I/O Port Table.

SEQUENCE OF SystemResourceIOPortTableEntry

Not accessible

Table 387. System Resource I/O Port Table Entry

Name systemResourceIOPortTableEntry

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.500.30.1

Defines the System Resource I/O Port Table entry.

SystemResourceIOPortTableEntry

Not accessible systemResourceIOPortchassisIndex

, systemResourceIOPortIndex

Table 388. System Resource I/O Port Chassis Index

Name

Object ID

Description

Syntax

Access systemResourceIOPortchassisIndex

1.3.6.1.4.1.674.10892.1.500.30.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Server Administrator Group 95

Table 389. System Resource I/O Port Index

Name

Object ID

Description

Syntax

Access systemResourceIOPortIndex

1.3.6.1.4.1.674.10892.1.500.30.1.2

Defines the index (one-based) of the system resource I/O ports in this chassis.

DellObjectRange

Read-only

Table 390. System Resource I/O Port State Capabilities

Name

Object ID

Description

Syntax

Access systemResourceIOPortStateCapabilities

1.3.6.1.4.1.674.10892.1.500.30.1.3

Defines the capabilities of the system resource I/O port.

DellStateCapabilities

Read-only

Table 391. System Resource I/O Port State Settings

Name

Object ID

Description

Syntax

Access systemResourceIOPortStateSettings

1.3.6.1.4.1.674.10892.1.500.30.1.4

Defines the state and allows the setting of the system resource I/O port.

DellStateSettings

Read-only

Table 392. System Resource I/O Port Status

Name

Object ID

Description

Syntax

Access systemResourceIOPortStatus

1.3.6.1.4.1.674.10892.1.500.30.1.5

Defines the status of the system resource I/O port.

DellStateSettings

Read-only

Table 393. System Resource I/O Port Owner Index Reference

Name

Object ID

Description

Syntax

Access systemResourceIOPortOwnerIndexReference

1.3.6.1.4.1.674.10892.1.500.30.1.6

Defines the index to the associated system resource owner in this chassis.

DellObjectRange

Read-only

Table 394. System Resource I/O Port Share Disposition

Name

Object ID

Description

Syntax

Access systemResourceIOPortShareDisposition

1.3.6.1.4.1.674.10892.1.500.30.1.7

Defines the share disposition of the system resource I/O port.

DellResourceShareDisposition (

Resource Share Disposition

)

Read-only

96 Server Administrator Group

Table 395. System Resource I/O Port Starting Address

Name

Object ID

Description

Syntax

Access systemResourceIOPortStartingAddress

1.3.6.1.4.1.674.10892.1.500.30.1.8

Defines the 64 bits of the starting address of the system resource I/O port.

DellUnsigned64BitRange

Read-only

Table 396. System Resource I/O Port Ending Address

Name

Object ID

Description

Syntax

Access systemResourceIOPortEndingAddress

1.3.6.1.4.1.674.10892.1.500.30.1.9

Defines the 64 bits of the ending address of the system resource I/O port.

DellUnsigned64BitRange

Read-only

System Resource Memory Table

Table 397. System Resource Memory Table

Name

Object

Description

Syntax

Access systemResourceMemoryTable

1.3.6.1.4.1.674.10892.1.500.40

Defines the System Resource Memory Table.

SEQUENCE OF SystemResourceMemoryTableEntry

Not accessible

Table 398. System Resource Memory Table Entry

Name systemResourceMemoryTableEntry

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.500.40.1

Defines the System Resource Memory Table entry.

SystemResourceMemoryTableEntry

Not accessible systemResourceMemorychassisIndex

, systemResourceMemoryIndex

Table 399. System Resource Memory Chassis Index

Name

Object ID

Description

Syntax

Access systemResourceMemorychassisIndex

1.3.6.1.4.1.674.10892.1.500.40.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Server Administrator Group 97

Table 400. System Resource Memory Index

Name

Object ID

Description

Syntax

Access systemResourceMemoryIndex

1.3.6.1.4.1.674.10892.1.500.40.1.2

Defines the index of system resource memory in this chassis.

DellObjectRange

Read-only

Table 401. System Resource Memory State Capabilities

Name

Object ID

Description

Syntax

Access systemResourceMemoryStateCapabilities

1.3.6.1.4.1.674.10892.1.500.40.1.3

Defines the capabilities of this system resource memory.

DellObjectRange

Read-only

Table 402. System Resource Memory State Settings

Name

Object ID

Description

Syntax

Access systemResourceMemoryStateSettings

1.3.6.1.4.1.674.10892.1.500.40.1.4

Defines the state of this system resource memory.

DellObjectRange

Read-only

Table 403. System Resource Memory Status

Name

Object ID

Description

Syntax

Access systemResourceMemoryStatus

1.3.6.1.4.1.674.10892.1.500.40.1.5

Defines the status of this system resource memory.

DellStatus

Read-only

Table 404. System Resource Memory Owner Index Reference

Name

Object ID

Description

Syntax

Access systemResourceMemoryOwnerIndexReference

1.3.6.1.4.1.674.10892.1.500.40.1.6

Defines the index to the associated system resource owner in this chassis.

DellObjectRange

Read-only

Table 405. System Resource Memory Share Disposition

Name

Object ID

Description

Syntax

Access systemResourceMemoryShareDisposition

1.3.6.1.4.1.674.10892.1.500.40.1.7

Defines the share disposition of the system resource memory.

DellResourceShareDisposition (

Resource Share Disposition

)

Read-only

98 Server Administrator Group

Table 406. System Resource Memory Starting Address

Name

Object ID

Description

Syntax

Access systemResourceMemoryStartingAddress

1.3.6.1.4.1.674.10892.1.500.40.1.8

Defines the 64 bits of the starting address of the system resource memory.

DellUnsigned64BitRange

Read-only

Table 407. System Resource Memory Ending Address

Name

Object ID

Description

Syntax

Access systemResourceMemoryEndingAddress

1.3.6.1.4.1.674.10892.1.500.40.1.9

Defines the 64 bits of the ending address of the system resource memory.

DellUnsigned64BitRange

Read-only

Table 408. System Resource Memory Flags

Name

Object ID

Description

Syntax

Access systemResourceMemoryFlags

1.3.6.1.4.1.674.10892.1.500.40.1.10

Defines the permission flags for the system resource memory.

DellResourceMemoryFlags ( Resource Memory Flags )

Read-only

System Resource Interrupt Table

Table 409. System Resource Interrupt Table

Name systemResourceInterruptTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.500.50

Defines the System Resource Interrupt Table.

SEQUENCE OF SystemResourceInterruptTableEntry

Not accessible

Table 410. System Resource Interrupt Table Entry

Name

Object ID

Description

Syntax

Access

Index systemResourceInterruptTableEntry

1.3.6.1.4.1.674.10892.1.500.50.1

Defines the System Resource Interrupt Table entry.

SystemResourceInterruptTableEntry

Not accessible systemResourceInterruptchassisIndex

, systemResourceInterruptIndex

Server Administrator Group 99

Table 411. System Resource Interrupt Chassis Index

Name

Object ID

Description

Syntax

Access systemResourceInterruptchassisIndex

1.3.6.1.4.1.674.10892.1.500.50.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Not accessible

Table 412. System Resource Interrupt Index

Name

Object ID

Description

Syntax

Access systemResourceInterruptIndex

1.3.6.1.4.1.674.10892.1.500.50.1.2

Defines the index (one-based) of this interrupt resource.

DellObjectRange

Read-only

Table 413. System Resource Interrupt State Capabilities

Name

Object ID

Description

Syntax

Access systemResourceInterruptStateCapabilities

1.3.6.1.4.1.674.10892.1.500.50.1.3

Defines the capabilities of this system resource interrupt.

DellStateCapabilities

Read-only

Table 414. System Resource Interrupt State Settings

Name

Object ID

Description

Syntax

Access systemResourceInterruptStateSettings

1.3.6.1.4.1.674.10892.1.500.50.1.4

Defines the state of this system resource interrupt.

DellStateSettings

Read-only

Table 415. System Resource Interrupt Status

Name

Object ID

Description

Syntax

Access systemResourceInterruptStatus

1.3.6.1.4.1.674.10892.1.500.50.1.5

Defines the status of this system resource interrupt.

DellStatus

Read-only

Table 416. System Resource Interrupt Owner Index Reference

Name

Object ID

Description

Syntax

Access systemResourceInterruptOwnerIndexReference

1.3.6.1.4.1.674.10892.1.500.50.1.6

Defines the index for the associated system resource owner in this chassis.

DellObjectRange

Read-only

100 Server Administrator Group

Table 417. System Resource Interrupt Owner Share Disposition

Name

Object ID

Description

Syntax

Access systemResourceInterruptShareDisposition

1.3.6.1.4.1.674.10892.1.500.50.1.7

Defines the share disposition of the system resource interrupt.

DellResourceShareDisposition (

Resource Share Disposition

)

Read-only

Table 418. System Resource Interrupt Level

Name

Object ID

Description

Syntax

Access systemResourceInterruptLevel

1.3.6.1.4.1.674.10892.1.500.50.1.8

Defines the interrupt request (IRQ) level of the system resource interrupt.

DellUnsigned32BitRange

Read-only

Table 419. System Resource Interrupt Type

Name

Object ID

Description

Syntax

Access systemResourceInterruptType

1.3.6.1.4.1.674.10892.1.500.50.1.9

Defines the interrupt type of the system resource interrupt.

DellResourceInterruptType ( Resource Interrupt Type

)

Read-only

Table 420. System Resource Interrupt Trigger

Name

Object ID

Description

Syntax

Access systemResourceInterruptTrigger

1.3.6.1.4.1.674.10892.1.500.50.1.10

Defines the interrupt trigger of the system resource interrupt.

DellResourceInterruptTrigger (

Resource Interrupt Trigger

)

Read-only

System Resource Direct Memory Access Table

Table 421. System Resource Direct Memory Access Table

Name

Object ID

Description

Syntax

Access systemResourceDMATable

1.3.6.1.4.1.674.10892.1.500.60

Defines the System Resource DMA Table.

SEQUENCE OF SystemResourceDMATableEntry

Not accessible

Table 422. System Resource DMA Table Entry

Name

Object ID

Description

Syntax systemResourceDMATable

1.3.6.1.4.1.674.10892.1.500.60.1

Defines the System Resource DMA Table entry.

SystemResourceDMATableEntry

Server Administrator Group 101

Table 422. System Resource DMA Table Entry (continued)

Access

Index

Not accessible systemResourceDMAchassisIndex

, systemResourceDMAIndex

Table 423. System Resource DMA Chassis Index

Name

Object ID

Description

Syntax

Access systemResourceDMAchassisIndex

1.3.6.1.4.1.674.10892.1.500.60.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 424. System Resource DMA Index

Name

Object ID

Description

Syntax

Access systemResourceDMAIndex

1.3.6.1.4.1.674.10892.1.500.60.1.2

Defines the index of system resource DMAs in this chassis.

DellObjectRange

Read-only

Table 425. System Resource DMA State Capabilities

Name

Object ID

Description

Syntax

Access systemResourceDMAStateCapabilities

1.3.6.1.4.1.674.10892.1.500.60.1.3

Defines the capabilities of this system resource DMA.

DellStateCapabilities

Read-only

Table 426. System Resource DMA State Settings

Name

Object ID

Description

Syntax

Access systemResourceDMAStateSettings

1.3.6.1.4.1.674.10892.1.500.60.1.4

Defines the state and setting of this system resource DMA.

DellStateSettings

Read-only

Table 427. System Resource DMA Status

Name systemResourceDMAStatus

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.500.60.1.5

Defines the status of this system resource DMA.

DellStatus

Read-only

102 Server Administrator Group

Table 428. System Resource DMA Owner Index Reference

Name

Object ID

Description

Syntax

Access systemResourceDMAOwnerIndexReference

1.3.6.1.4.1.674.10892.1.500.60.1.6

Defines the index to the associated system resource owner in this chassis.

DellObjectRange

Read-only

Table 429. System Resource DMA Share Disposition

Name

Object ID

Description

Syntax

Access systemResourceDMAShareDisposition

1.3.6.1.4.1.674.10892.1.500.60.1.7

Defines the share disposition of the system resource DMA.

DellResourceShareDisposition (

Resource Share Disposition

)

Read-only

Table 430. System Resource DMA Maximum Transfer Size

Name

Object ID

Description

Syntax

Access systemResourceDMAMaximumTransferSize

1.3.6.1.4.1.674.10892.1.500.60.1.8

Defines the maximum size of a memory transfer in bytes for the system resource DMA.

DellUnsigned32BitRange

Read-only

Table 431. System Resource DMA Transfer Width

Name

Object ID

Description

Syntax

Access systemResourceDMATransferWidth

1.3.6.1.4.1.674.10892.1.500.60.1.9

Defines the transfer width of the system resource DMA.

DellResourceDMATransferWidth (

Resource DMA Transfer Width

)

Read-only

Table 432. System Resource DMA Bus Primary

Name

Object ID

Description

Syntax

Access systemResourceDMABusPrimary

1.3.6.1.4.1.674.10892.1.500.60.1.10

Defines the bus control capabilities of the system resource DMA.

DellResourceDMABusPrimary

Read-only

System Resource Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 433. System Resource Map Type

Variable Name : DellSystemResourceMapType

Data Type : Integer

Possible Data Values Meaning of Data Value

Server Administrator Group 103

Table 433. System Resource Map Type (continued) other(1) unknown(2) typeOne(3)

The system resource map type is not one of the following:

The system resource map type is unknown (not known or not monitored).

The system resource map is type 1 (one).

Table 434. Resource Owner Interface Type

Variable Name : DellResourceOwnerInterfaceType

Data Type : Integer

Possible Data Values Meaning of Data Value typeIsOther(1) typeIsUnknown(2) typeIsInternal(3)

The interface type is not one of the following:

The interface type is unknown.

The interface type is internal.

typeIsISA(4) typeIsEISA(5) typeIsMCA(6) typeIsTurboChannel(7)

The interface type is an Industry Standard Architecture (ISA) bus.

The interface type is an Extended Industry Standard Architecture (EISA) bus.

The interface type is a microchannel architecture (MCA) bus.

The interface type is a turbo-channel bus.

Table 435. Resource Share Disposition

Variable Name : DellResourceShareDisposition

Data Type : Integer

Possible Data Values shareIsOther(1) shareIsUnknown(2)

Meaning of Data Value

The share disposition is not one of the following:

The share disposition is unknown (not known or not monitored).

shareIsDeviceExclusive(3) The share disposition is device exclusive.

shareIsDriverExclusive(4) The share disposition is driver exclusive.

shareIsShared(5) The share disposition is shared.

Table 436. Resource Memory Flags

Variable Name : DellResourceMemoryFlags

Data Type : Integer

Possible Data Values memoryIsReadOnly(1)

Meaning of Data Value

The resource memory is read-only.

memoryIsWriteOnly(2) memoryIsPreFetchable(4)

The resource memory is write-only.

The resource memory is prefetchable.

memoryIsCombinedWritable(8

) memoryIsF24(16)

The resource memory is read-write.

The resource memory is F24.

Table 437. Resource Interrupt Type

Variable Name : DellResourceInterruptType

Data Type : Integer

Possible Data Values Meaning of Data Value

104 Server Administrator Group

Table 437. Resource Interrupt Type (continued) interruptIsLevelSensitive(

1) interruptIsLatched(2)

The interrupt type is level sensitive.

The interrupt type is latched.

Table 438. Resource Interrupt Trigger

Variable Name : DellResourceInterruptTrigger

Data Type : Integer

Possible Data Values interruptIsActiveWhenLow(1

) interruptIsActiveWhenHigh(

2)

Meaning of Data Value

The interrupt trigger is active on a low signal.

The interrupt trigger is active on a high signal.

Table 439. Resource DMA Bus Primary

Variable Name : DellResourceDMABusPrimary

Data Type : Integer

Possible Data Values dmaIsOther(1)

Meaning of Data Value

The DMA bus control capability is not one of the following: dmaIsUnknown(2) dmaIsNotABusmaster(3)

The DMA bus control capability is unknown.

The DMA does not have any bus control capability.

Table 440. Resource DMA Transfer Width

Variable Name : DellResourceDMATransferWidth

Data Type : Integer

Possible Data Values Meaning of Data Value dmaTransferWidthIsOther(1) The DMA transfer width is not one of the following: dmaTransferWidthIsunknown(

2)

The DMA transfer width is unknown.

dmaTransferWidthIs8Bits(3) The DMA transfer width is 8 bits.

dmaTransferWidthIs16Bits(4

)

The DMA transfer width is 16 bits.

dmaTransferWidthIs32Bits(5

)

The DMA transfer width is 32 bits.

dmaTransferWidthIs64Bits(6

)

The DMA transfer width is 64 bits.

dmaTransferWidthIs128Bits(

7)

The DMA transfer width is 128 bits.

Power Group

The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes.

NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems that have a fixed, nonredundant power supply installed.

Server Administrator Group 105

Power Group Tables

The following management information base (MIB) tables define objects for the Power Group:

Power Unit Table

Power Supply Table

Voltage Probe Table

Amperage Probe Table

AC Power Switch Table

AC Power Cord Table

Battery Table

Power Usage Table

Power ProfileTable

Power Unit Table

Table 441. Power Unit Table

Name

Object ID

Description

Syntax

Access powerUnitTable

1.3.6.1.4.1.674.10892.1.600.10

Defines the Power Unit Table.

PowerUnitTableEntry

Not accessible

Table 442. Power Unit Table Entry

Name

Object ID

Description

Syntax

Access

Index powerUnitTableEntry

1.3.6.1.4.1.674.10892.1.600.10.1

Defines the Power Unit Table entry.

DellObjectRange

Read-only powerUnitchassisIndex , powerUnitIndex

Table 443. Power Unit Chassis Index

Name

Object ID

Description

Syntax

Access powerUnitchassisIndex

1.3.6.1.4.1.674.10892.1.600.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 444. Power Unit Index

Name

Object ID

Description

Syntax

Access powerUnitIndex

1.3.6.1.4.1.674.10892.1.600.10.1.2

Defines the index of the power unit in this chassis.

DellObjectRange

Read-only

106 Server Administrator Group

Table 445. Power Unit State Capabilities

Name

Object ID

Description

Syntax

Access powerUnitStateCapabilities

1.3.6.1.4.1.674.10892.1.600.10.1.3

Defines the capabilities of the power unit.

DellStateCapabilities

Read-only

Table 446. Power Unit State Settings

Name

Object ID

Description

Syntax

Access powerUnitStateSettings

1.3.6.1.4.1.674.10892.1.600.10.1.4

Defines the state and settings of the power unit.

DellStateSettings

Read-only

Table 447. Power Unit Redundancy Status

Name

Object ID

Description

Syntax

Access powerUnitRedundancyStatus

1.3.6.1.4.1.674.10892.1.600.10.1.5

Defines the redundancy status of the power unit.

DellStatusRedundancy

Read-only

Table 448. Power Supply Count for Redundancy

Name

Object ID

Description

Syntax

Access powerSupplyCountForRedundancy

1.3.6.1.4.1.674.10892.1.600.10.1.6

Defines the total number of power supplies required for this power unit to have redundancy.

DellString

Read-only

Table 449. Power Unit Name

Name

Object ID

Description

Syntax

Access powerUnitName

1.3.6.1.4.1.674.10892.1.600.10.1.7

Defines the name of the power unit in this chassis.

DellString

Read-only

Table 450. Power Unit Status

Name

Object ID

Description

Syntax

Access powerUnitStatus

1.3.6.1.4.1.674.10892.1.600.10.1.8

Defines the status of the power unit in this chassis.

DellStatus

Read-only

Server Administrator Group 107

Power Supply Table

Table 451. Power Supply Table

Name

Object ID

Description

Syntax

Access powerSupplyTable

1.3.6.1.4.1.674.10892.1.600.12

Defines the Power Supply Table.

PowerSupplyTableEntry

Not accessible

Table 452. Power Supply Table Entry

Name

Object ID

Description

Syntax

Access

Index powerSupplyTableEntry

1.3.6.1.4.1.674.10892.1.600.12.1

Defines the Power Supply Table entry.

PowerSupplyTableEntry

Not accessible powerSupplychassisIndex , powerSupplyIndex

Table 453. Power Supply Chassis Index

Name powerSupplychassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.600.12.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 454. Power Supply Index

Name

Object ID

Description

Syntax

Access powerSupplyIndex

1.3.6.1.4.1.674.10892.1.600.12.1.2

Defines the index of power supply.

DellObjectRange

Read-only

Table 455. Power Supply State Capabilities Unique

Name

Object ID

Description

Syntax

Access powerSupplyStateCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.600.12.1.3

Defines the capabilities of the power supply.

DellPowerSupplyStateCapabilitiesUnique (

Power Supply State Capabilities Unique )

Read-only

Table 456. Power Supply State Settings Unique

Name

Object ID

Description

Syntax powerSupplyStateSettingsUnique

1.3.6.1.4.1.674.10892.1.600.12.1.4

Defines the state and settings of the power supply.

DellPowerSupplyStateSettingsUnique ( Power Supply State Settings Unique

)

108 Server Administrator Group

Table 456. Power Supply State Settings Unique (continued)

Access Read-only

Table 457. Power Supply Status

Name

Object ID

Description

Syntax

Access powerSupplyStatus

1.3.6.1.4.1.674.10892.1.600.12.1.5

Defines the status of the power supply.

DellStatus

Read-only

Table 458. Power Supply Output Watts

Name

Object ID

Description

Syntax

Access powerSupplyOutputWatts

1.3.6.1.4.1.674.10892.1.600.12.1.6

Defines the maximum sustained output wattage of the power supply in tenths of watts.

DellSigned32BitRange

Read-only

Table 459. Power Supply Type

Name

Object ID

Description

Syntax

Access powerSupplyType

1.3.6.1.4.1.674.10892.1.600.12.1.7

Defines the type of power supply.

DellPowerSupplyType ( Power Supply Type Definitions

)

Read-only

Table 460. Power Supply Location Name

Name

Object ID

Description

Syntax

Access powerSupplyLocationName

1.3.6.1.4.1.674.10892.1.600.12.1.8

Defines the location name of the power supply.

DellString

Read-only

Table 461. Power Supply Maximum Input Voltage

Name

Object ID

Description

Syntax

Access powerSupplyMaximumInputVoltage

1.3.6.1.4.1.674.10892.1.600.12.1.9

This attribute defines the maximum input voltage of the power supply (in Volts).

DellSigned32BitRange

Read-only

Table 462. Power Supply Power Unit Index Reference

Name

Object ID

Description

Syntax powerSupplypowerUnitIndexReference

1.3.6.1.4.1.674.10892.1.600.12.1.10

Defines the index to the associated system power unit in this chassis.

DellObjectRange

Server Administrator Group 109

Table 462. Power Supply Power Unit Index Reference (continued)

Access Read-only

Table 463. Power Supply Sensor State

Name

Object ID

Description

Syntax

Access powerSupplySensorState

1.3.6.1.4.1.674.10892.1.600.12.1.11

Defines the state reported by the power supply sensor, and supplements the state and settings of the power supply.

DellPowerSupplySensorState (

Power Supply Sensor State )

Read-only

Table 464. Power Supply Configuration Error Type

Name

Object ID

Description

Syntax

Access powerSupplyConfigurationErrorType

1.3.6.1.4.1.674.10892.1.600.12.1.12

Defines the type of configuration error reported by the power supply sensor.

DellPowerSupplyConfigurationErrorType (

Power Supply Configuration Error Type )

Read-only

Table 465. Power Supply Power Monitor Capable

Name

Object ID

Description

Syntax

Access powerSupplyPowerMonitorCapable

1.3.6.1.4.1.674.10892.1.600.12.1.13

Defines a boolean value that reports whether the power supply is capable of monitoring power consumption.

DellBoolean

Read-only

Table 466. Power Supply Rated Input Wattage

Name

Object ID

Description

Syntax

Access powerSupplyRatedInputWattage

1.3.6.1.4.1.674.10892.1.600.12.1.14

Defines the rated input wattage of the power supply (in tenths of Watts.)

DellSigned32BitRange

Read-only

Table 467. Power Supply FQDD

Name

Object ID

Description

Syntax

Access powerSupplyFQDD

1.3.6.1.4.1.674.10892.1.600.12.1.15

Fully qualified device descriptor (FQDD) of the power supply.

FQDDString

Read-only

Table 468. Power Supply Current Input Voltage

Name

Object ID

Description powerSupplyCurrentInputVoltage

1.3.6.1.4.1.674.10892.1.600.12.1.16

This attribute defines the current input voltage to the power supply (in Volts).

110 Server Administrator Group

Table 468. Power Supply Current Input Voltage (continued)

Syntax

Access

DellSigned32BitRange

Read-only

Voltage Probe Table

Table 469. Voltage Probe Table

Name

Object ID

Description

Syntax

Access voltageProbeTable

1.3.6.1.4.1.674.10892.1.600.20

Defines the Voltage Probe Table.

VoltageProbeTableEntry

Not accessible

Table 470. Voltage Probe Table Entry

Name

Object ID

Description

Syntax

Access

Index voltageProbeTableEntry

1.3.6.1.4.1.674.10892.1.600.20.1

Defines the Voltage Probe Table entry.

VoltageProbeTableEntry

Not accessible voltageProbechassisIndex , voltageProbeIndex

Table 471. Voltage Probe Chassis Index

Name

Object ID

Description

Syntax

Access voltageProbechassisIndex

1.3.6.1.4.1.674.10892.1.600.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 472. Voltage Probe Index

Name

Object ID

Description

Syntax

Access voltageProbeIndex

1.3.6.1.4.1.674.10892.1.600.20.1.2

Defines the index of voltage probes in this chassis.

DellObjectRange

Read-only

Table 473. Voltage Probe State Capabilities

Name

Object ID

Description

Syntax

Access voltageProbeStateCapabilities

1.3.6.1.4.1.674.10892.1.600.20.1.3

Defines the capabilities of the voltage probe.

DellStateCapabilities

Read-only

Server Administrator Group 111

Table 474. Voltage Probe State Settings

Name

Object ID

Description

Syntax

Access voltageProbeStateSettings

1.3.6.1.4.1.674.10892.1.600.20.1.4

Defines the state and settings of the voltage probe.

DellStateSettings

Read-only

Table 475. Voltage Probe Status

Name

Object ID

Description

Syntax

Access voltageProbeStatus

1.3.6.1.4.1.674.10892.1.600.20.1.5

Defines the status of the voltage probe.

DellStatusProbe

Read-only

Table 476. Voltage Probe Reading

Name

Object ID

Description

Syntax

Access voltageProbeReading

1.3.6.1.4.1.674.10892.1.600.20.1.6

Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute.

DellSigned32BitRange

Read-only

Table 477. Voltage Probe Type

Name

Object ID

Description

Syntax

Access voltageProbeType

1.3.6.1.4.1.674.10892.1.600.20.1.7

Defines the type of the voltage probe.

DellVoltageType

Read-only

Table 478. Voltage Probe Location Name

Name

Object ID

Description

Syntax

Access voltageProbeLocationName

1.3.6.1.4.1.674.10892.1.600.20.1.8

Defines the location of the voltage probe in this chassis.

DellString

Read-only

Table 479. Voltage Probe Upper Nonrecoverable Threshold

Name

Object ID

Description

Syntax

Access voltageProbeUpperNonRecoverableThreshold

1.3.6.1.4.1.674.10892.1.600.20.1.9

Defines the value of the voltage probe’s upper nonrecoverable threshold.

DellSigned32BitRange

Read-only

112 Server Administrator Group

Table 480. Voltage Probe Upper Critical Threshold

Name

Object ID

Description

Syntax

Access voltageProbeUpperCriticalThreshold

1.3.6.1.4.1.674.10892.1.600.20.1.10

Defines the value of the voltage probe’s upper critical threshold.

DellSigned32BitRange

Read-only

Table 481. Voltage Probe Upper Noncritical Threshold

Name

Object ID

Description

Syntax

Access voltageProbeUpperNonCriticalThreshold

1.3.6.1.4.1.674.10892.1.600.20.1.11

Defines the user-assigned value of the voltage probe’s upper noncritical threshold.

DellSigned32BitRange

Read-only

Table 482. Voltage Probe Lower Noncritical Threshold

Name

Object ID

Description

Syntax

Access voltageProbeLowerNonCriticalThreshold

1.3.6.1.4.1.674.10892.1.600.20.1.12

Defines the user-assigned value of the voltage probe’s lower noncritical threshold.

DellSigned32BitRange

Read-only

Table 483. Voltage Probe Lower Critical Threshold

Name

Object ID

Description

Syntax

Access voltageProbeLowerCriticalThreshold

1.3.6.1.4.1.674.10892.1.600.20.1.13

Defines the value of the voltage probe’s lower critical threshold.

DellSigned32BitRange

Read-only

Table 484. Voltage Probe Lower Nonrecoverable Threshold

Name

Object ID

Description

Syntax

Access voltageProbeLowerNonRecoverableThreshold

1.3.6.1.4.1.674.10892.1.600.20.1.14

Defines the value of the voltage probe’s lower nonrecoverable threshold.

DellSigned32BitRange

Read-only

Table 485. Voltage Probe Capabilities

Name

Object ID

Description

Syntax

Access voltageProbeProbeCapabilities

1.3.6.1.4.1.674.10892.1.600.20.1.15

Defines the probe capabilities of the voltage probe.

DellProbeCapabilities

Read-only

Server Administrator Group 113

Table 486. Voltage Probe Discrete Reading

Name

Object ID

Description voltageProbeDiscreteReading

1.3.6.1.4.1.674.10892.1.600.20.1.16

Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete.

When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.

Syntax

Access

DellVoltageDiscreteReading

Read-only

Amerage Probe Table

Table 487. Amerage Probe Table

Name

Object ID

Description

Syntax

Access amperageProbeTable

1.3.6.1.4.1.674.10892.1.600.30

Defines the Amperage Probe Table.

SEQUENCE OF AmperageProbeTableEntry

Not accessible

Table 488. Amperage Probe Table Entry

Name

Object ID

Description

Syntax

Access

Index amperageProbeTableEntry

1.3.6.1.4.1.674.10892.1.600.30.1

Defines the Amperage Probe Table entry.

AmperageProbeTableEntry

Not accessible amperageProbechassisIndex

, amperageProbeIndex

Table 489. Amperage Probe Chassis Index

Name

Object ID

Description

Syntax

Access amperageProbechassisIndex

1.3.6.1.4.1.674.10892.1.600.30.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 490. Amperage Probe Index

Name

Object ID

Description amperageProbeIndex

1.3.6.1.4.1.674.10892.1.600.30.1.2

Defines the index of amperage probes in this chassis.

114 Server Administrator Group

Table 490. Amperage Probe Index (continued)

Syntax

Access

DellObjectRange

Read-only

Table 491. Amperage Probe State Capabilities

Name

Object ID

Description

Syntax

Access amperageProbeStateCapabilities

1.3.6.1.4.1.674.10892.1.600.30.1.3

Defines the capabilities of the amperage probe.

DellStateCapabilities

Read-only

Table 492. Amperage Probe State Settings

Name

Object ID

Description

Syntax

Access amperageProbeStateSettings

1.3.6.1.4.1.674.10892.1.600.30.1.4

Defines the state and settings of the amperage probe.

DellStateSettings

Read-only

Table 493. Amperage Probe Status

Name

Object ID

Description

Syntax

Access amperageProbeStatus

1.3.6.1.4.1.674.10892.1.600.30.1.5

Defines the status of the amperage probe.

DellSigned32BitRange

Read-only

Table 494. Amperage Probe Reading

Name

Object ID

Description

Syntax

Access amperageProbeReading

1.3.6.1.4.1.674.10892.1.600.30.1.6

Defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete.

When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps, the value returned for this attribute is the power usage that the probe is reading in tenths of Amperes.

When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts, the value returned for this attribute is the power usage that the probe is reading in Watts.

When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, amperageProbeTypeIsPowerSupplyAmps, amperageProbeTypeIsPowerSupplyWatts, amperageProbeTypeIsSystemAmps, or amperageProbeTypeIsSystemWatts, the value returned for this attribute is the amperage that the probe is reading in Milliamps.

When the value for amperageProbeType is amperageProbeTypeIsDiscrete, a value is not returned for this attribute.

DellSigned32BitRange

Read-only

Server Administrator Group 115

Table 495. Amperage Probe Type

Name

Object ID

Description

Syntax

Access amperageProbeType

1.3.6.1.4.1.674.10892.1.600.30.1.7

Defines the type of the amperage probe.

DellAmperageProbeType

Read-only

Table 496. Amperage Probe Location Name

Name

Object ID

Description

Syntax

Access amperageProbeLocationName

1.3.6.1.4.1.674.10892.1.600.30.1.8

Defines the location name of the amperage probe in this chassis.

DellString

Read-only

Table 497. Amperage Probe Upper Nonrecoverable Threshold

Name

Object ID

Description

Syntax

Access amperageProbeUpperNonRecoverableThreshold

1.3.6.1.4.1.674.10892.1.600.30.1.9

Defines the value of the amperage probe’s upper nonrecoverable threshold. The value is an integer representing the amperage in milliamperes that the probe is reading.

DellSigned32BitRange

Read-only

Table 498. Amperage Probe Upper Critical Threshold

Name amperageProbeUpperCriticalThreshold

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.600.30.1.10

Defines the value of the amperage probe’s upper critical threshold.

DellSigned32BitRange

Read-only

Table 499. Amperage Probe Upper Noncritical Threshold

Name

Object ID

Description

Syntax

Access amperageProbeUpperNonCriticalThreshold

1.3.6.1.4.1.674.10892.1.600.30.1.11

Defines the user-assigned value of the amperage probe’s upper critical threshold.

DellSigned32BitRange

Read-only

Table 500. Amperage Probe Lower Noncritical Threshold

Name

Object ID

Description

Syntax

Access amperageProbeLowerNonCriticalThreshold

1.3.6.1.4.1.674.10892.1.600.30.1.12

Defines the user-assigned value of the amperage probe’s lower noncritical threshold.

DellSigned32BitRange

Read-only

116 Server Administrator Group

Table 501. Amperage Probe Lower Critical Threshold

Name

Object ID

Description

Syntax

Access amperageProbeLowerCriticalThreshold

1.3.6.1.4.1.674.10892.1.600.30.1.13

Defines the value of the amperage probe’s lower critical threshold.

DellSigned32BitRange

Read-only

Table 502. Amperage Probe Lower Nonrecoverable Threshold

Name

Object ID

Description

Syntax

Access amperageProbeLowerNonRecoverableThreshold

1.3.6.1.4.1.674.10892.1.600.30.1.14

Defines the value of the amperage probe’s lower nonrecoverable threshold.

DellSigned32BitRange

Read-only

Table 503. Amperage Probe Probe Capabilities

Name

Object ID

Description

Syntax

Access amperageProbeProbeCapabilities

1.3.6.1.4.1.674.10892.1.600.30.1.15

Defines the probe capabilities of the amperage probe.

DellProbeCapabilities

Read-only

Table 504. Amperage Probe Discrete Reading

Name

Object ID

Description amperageProbeDiscreteReading

1.3.6.1.4.1.674.10892.1.600.30.1.16

Defines the reading for a amperage probe of type amperageProbeTypeIsDiscrete.

When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.

Syntax

Access

DellAmperageDiscreteReading ( Amperage Probe Discrete Reading

)

Read-only

AC Power Switch Table

Table 505. AC Power Switch Table

Name

Object ID

Description

Syntax

Access aCPowerSwitchTable

1.3.6.1.4.1.674.10892.1.600.40

Defines the AC Power Switch Table.

SEQUENCE OF ACPowerSwitchTableEntry

Not accessible

Table 506. AC Power Switch Table Entry

Name aCPowerSwitchTableEntry

Server Administrator Group 117

Table 506. AC Power Switch Table Entry (continued)

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.600.40.1

Defines the AC Power Switch Table entry.

ACPowerSwitchTableEntry

Not accessible aCPowerSwitchchassisIndex

, aCPowerSwitchIndex

Table 507. AC Power Switch Chassis Index

Name

Object ID

Description

Syntax

Access aCPowerSwitchChassisIndex

1.3.6.1.4.1.674.10892.1.600.40.1.1

Defines the index (one-based) of the chassis containing this AC power switch.

DellObjectRange

Read-only

Table 508. AC Power Switch Index

Name

Object ID

Description

Syntax

Access aCPowerSwitchIndex

1.3.6.1.4.1.674.10892.1.600.40.1.2

Defines the index (one-based) of this AC power switch.

DellObjectRange

Read-only

Table 509. AC Power Switch Capabilities

Name

Object ID

Description

Syntax

Access aCPowerSwitchCapabilities

1.3.6.1.4.1.674.10892.1.600.40.1.3

Defines the capabilities of this AC power switch.

DellACPowerSwitchCapabilities

Read-only

Table 510. AC Power Switch Settings

Name

Object ID

Description

Syntax

Access aCPowerSwitchSettings

1.3.6.1.4.1.674.10892.1.600.40.1.4

Defines the settings of this AC power switch.

DellACPowerSwitchSettings

Read-only

Table 511. AC Power Switch Redundancy Status

Name

Object ID

Description aCPowerSwitchRedundancyStatus

1.3.6.1.4.1.674.10892.1.600.40.1.5

Defines the redundancy status of this AC power switch.

118 Server Administrator Group

Table 511. AC Power Switch Redundancy Status (continued)

Syntax

Access

DellStatusRedundancy

Read-only

Table 512. AC Power Cord Count for Redundancy

Name

Object ID

Description

Syntax

Access aCPowerCordCountForRedundancy

1.3.6.1.4.1.674.10892.1.600.40.1.6

Defines the total number of AC power cords required for this AC power switch to have redundancy.

DellObjectRange

Read-only

Table 513. AC Power Switch Name

Name

Object ID

Description

Syntax

Access aCPowerSwitchName

1.3.6.1.4.1.674.10892.1.600.40.1.7

Defines the name of this AC power switch.

DellString

Read-only

Table 514. AC Power Switch Redundancy Mode

Name

Object ID

Description

Syntax

Access aCPowerSwitchRedundancyMode

1.3.6.1.4.1.674.10892.1.600.40.1.8

Defines the redundancy mode of this AC power switch.

DellACPowerSwitchRedundancyMode

Read-only

Table 515. AC Power Switch Status

Name

Object ID

Description

Syntax

Access aCPowerSwitchStatus

1.3.6.1.4.1.674.10892.1.600.40.1.9

Defines the status of this AC power switch.

DellStatus

Read-only

AC Power Cord Table

Table 516. AC Power Cord Table

Name

Object ID

Description

Syntax

Access aCPowerCordTable

1.3.6.1.4.1.674.10892.1.600.42

Defines the AC Power Cord Table.

SEQUENCE OF ACPowerCordTableEntry

Not accessible

Server Administrator Group 119

Table 517. AC Power Cord Table Entry

Name

Object ID

Description

Syntax

Access

Index aCPowerCordTableEntry

1.3.6.1.4.1.674.10892.1.600.42.1

Defines the AC Power Cord Table entry.

ACPowerCordTableEntry

Not accessible aCPowerCordchassisIndex

, aCPowerCordIndex

Table 518. AC Power Cord Chassis Index

Name

Object ID

Description

Syntax

Access aCPowerCordChassisIndex

1.3.6.1.4.1.674.10892.1.600.42.1.1

Defines the index (one-based) of the chassis containing this AC power cord.

DellObjectRange

Read-only

Table 519. AC Power Cord Index

Name

Object ID

Description

Syntax

Access aCPowerCordIndex

1.3.6.1.4.1.674.10892.1.600.42.1.2

Defines the index (one-based) of this AC power cord.

DellObjectRange

Read-only

Table 520. AC Power Cord State Capabilities

Name

Object ID

Description

Syntax

Access aCPowerCordStateCapabilities

1.3.6.1.4.1.674.10892.1.600.42.1.3

Defines the capabilities of this AC power cord.

DellACPowerCordStateCapabilities

Read-only

Table 521. AC Power Cord State Settings

Name

Object ID

Description

Syntax

Access aCPowerCordStateSettings

1.3.6.1.4.1.674.10892.1.600.42.1.4

Defines the settings of this AC power cord.

DellACPowerCordStateSettings

Read-only

Table 522. AC Power Cord Status

Name

Object ID aCPowerCordStatus

1.3.6.1.4.1.674.10892.1.600.42.1.5

120 Server Administrator Group

Table 522. AC Power Cord Status (continued)

Description

Syntax

Access

Defines the status of this AC power cord.

DellStatus

Read-only

Table 523. AC Power Cord AC Power Switch Index Reference

Name

Object ID

Description

Syntax

Access aCPowerCordaCPowerSwitchIndexReference

1.3.6.1.4.1.674.10892.1.600.42.1.6

Defines the index (one-based) to the associated AC power switch for this AC power cord.

DellObjectRange

Read-only

Table 524. AC Power Cord Location Name

Name aCPowerCordLocationName

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.600.42.1.7

Defines the location name of this AC power cord.

DellString

Read-only

Battery Table

Table 525. Battery Table

Name

Object ID

Description

Syntax

Access batteryTable

1.3.6.1.4.1.674.10892.1.600.50

Defines the Battery Table.

SEQUENCE OF BatteryTableEntry

Not accessible

Table 526. Battery Table Entry

Name

Object ID

Description

Syntax

Access

Index batteryTableEntry

1.3.6.1.4.1.674.10892.1.600.50.1

Defines the Battery Table Entry.

BatteryTableEntry

Not accessible batteryChassisIndex , batteryIndex

Table 527. Battery Chassis Index

Name

Object ID

Description

Syntax batteryChassisIndex

1.3.6.1.4.1.674.10892.1.600.50.1.1

Defines the index (one-based) of the chassis that contains the battery.

DellObjectRange

Server Administrator Group 121

Table 527. Battery Chassis Index (continued)

Access Read-only

Table 528. Battery Index

Name

Object ID

Description

Syntax

Access batteryIndex

1.3.6.1.4.1.674.10892.1.600.50.1.2

Defines the index (one-based) of the battery.

DellObjectRange

Read-only

Table 529. Battery State Capabilities

Name

Object ID

Description

Syntax

Access batteryStateCapabilities

1.3.6.1.4.1.674.10892.1.600.50.1.3

Defines the state capabilities of the battery.

DellStateCapabilities

Read-only

Table 530. Battery State Settings

Name batteryStateSettings

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.600.50.1.4

Defines the state settings of the battery.

DellStateSettings

Read-only

Table 531. Battery Status

Name

Object ID

Description

Syntax

Access batteryStatus

1.3.6.1.4.1.674.10892.1.600.50.1.5

Defines the status of the battery.

DellStatus

Read-only

Table 532. Battery Reading

Name

Object ID

Description

Syntax

Access batteryReading

1.3.6.1.4.1.674.10892.1.600.50.1.6

Defines the reading of the battery.

DellBatteryReading (

Battery Reading

)

Read-only

Table 533. Battery Location Name

Name

Object ID

Description

Syntax batteryLocationName

1.3.6.1.4.1.674.10892.1.600.50.1.7

Defines the location of the battery.

DellString

122 Server Administrator Group

Table 533. Battery Location Name (continued)

Access Read-only

Power Usage Table

Table 534. Power Usage Table

Name

Object ID

Description

Syntax

Access powerUsageTable

1.3.6.1.4.1.674.10892.1.600.60

Defines the Power Usage Table.

SEQUENCE OF PowerUsageTableEntry

Not accessible

Table 535. Power Usage Table Entry

Name

Object ID

Description

Syntax

Access

Index powerUsageTableEntry

1.3.6.1.4.1.674.10892.1.600.60.1

Defines the Power Usage Table Entry.

PowerUsageTableEntry

Not accessible powerUsageChassisIndex , powerUsageIndex

Table 536. Power Usage Chassis Index

Name

Object ID

Description

Syntax

Access powerUsageChassisIndex

1.3.6.1.4.1.674.10892.1.600.60.1.1

Defines the index (one-based) of the associated chassis.

DellObjectRange

Read-only

Table 537. Power Usage Index

Name

Object ID

Description

Syntax

Access powerUsageIndex

1.3.6.1.4.1.674.10892.1.600.60.1.2

Defines the index (one-based) of the power usage information.

DellObjectRange

Read-only

Table 538. Power Usage State Capabilities

Name

Object ID

Description

Syntax

Access powerUsageStateCapabilities

1.3.6.1.4.1.674.10892.1.600.60.1.3

Defines the state capabilities of the power usage information.

DellStateCapabilities

Read-only

Table 539. Power Usage State Settings

Name powerUsageStateSettings

Server Administrator Group 123

Table 539. Power Usage State Settings (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.600.60.1.4

Defines the state settings of the power usage information.

DellStateSettings

Read-only

Table 540. Power Usage Status

Name

Object ID

Description

Syntax

Access powerUsageStatus

1.3.6.1.4.1.674.10892.1.600.60.1.5

Defines the status of the power usage information.

DellStatus

Read-only

Table 541. Power Usage Entity Name

Name

Object ID

Description

Syntax

Access powerUsageEntityName

1.3.6.1.4.1.674.10892.1.600.60.1.6

Defines the name of the entity associated with this power usage information.

DellString

Read-only

Table 542. Power Usage Cumulative Wattage

Name

Object ID

Description

Syntax

Access powerUsageCumulativeWattage

1.3.6.1.4.1.674.10892.1.600.60.1.7

Defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute.

DellUnsigned32BitRange

Read-only

Table 543. Power Usage Cumulative Wattage Start Date Name

Name

Object ID

Description

Syntax

Access powerUsageCumulativeWattageStartDateName

1.3.6.1.4.1.674.10892.1.600.60.1.8

Defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage attribute.

DellDateName

Read-only

Table 544. Power Usage Peak Watts

Name

Object ID

Description

Syntax

Access powerUsagePeakWatts

1.3.6.1.4.1.674.10892.1.600.60.1.9

Defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute.

DellUnsigned32BitRange

Read-only

124 Server Administrator Group

Table 545. Power Usage Peak Watts Start Date Name

Name

Object ID

Description

Syntax

Access powerUsagePeakWattsStartDateName

1.3.6.1.4.1.674.10892.1.600.60.1.10

Defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute.

DellDateName

Read-only

Table 546. Power Usage Peak Watts Reading Date Name

Name

Object ID

Description

Syntax

Access powerUsagePeakWattsReadingDateName

1.3.6.1.4.1.674.10892.1.600.60.1.11

Defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured.

DellDateName

Read-only

Table 547. Power Usage Peak Amps

Name

Object ID

Description

Syntax

Access powerUsagePeakAmps

1.3.6.1.4.1.674.10892.1.600.60.1.12

Defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute.

DellUnsigned32BitRange

Read-only

Table 548. Power Usage Peak Amps Start Date Name

Name

Object ID

Description

Syntax

Access powerUsagePeakAmpsStartDateName

1.3.6.1.4.1.674.10892.1.600.60.1.13

Defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute.

DellDateName

Read-only

Table 549. Power Usage Peak Amps Reading Date Name

Name

Object ID

Description

Syntax

Access powerUsagePeakAmpsReadingDateName

1.3.6.1.4.1.674.10892.1.600.60.1.14

Defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured.

DellDateName

Read-only

Table 550. Power Usage Idle Power

Name

Object ID

Description powerUsageIdlePower

1.3.6.1.4.1.674.10892.1.600.60.1.15

Defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration.

Server Administrator Group 125

Table 550. Power Usage Idle Power (continued)

Syntax

Access

DellUnsigned32BitRange

Read-only

Table 551. Power Usage Max Potential Power

Name

Object ID

Description

Syntax

Access powerUsageMaxPotentialPower

1.3.6.1.4.1.674.10892.1.600.60.1.16

Defines the maximum potential power (in Watts) of the system. This is the maximum power the system can consume based on the current hardware configuration.

DellUnsigned32BitRange

Read-only

Table 552. Power Usage Power Cap Capabilities

Name

Object ID

Description

Syntax

Access powerUsagePowerCapCapabilities

1.3.6.1.4.1.674.10892.1.600.60.1.17

Defines the system power cap capabilities.

DellPowerCapCapabilities

Read-only

Table 553. Power Usage Power Cap Setting

Name

Object ID

Description

Syntax

Access powerUsagePowerCapSetting

1.3.6.1.4.1.674.10892.1.600.60.1.18

Defines the system power cap setting.

DellPowerCapSetting

Read-only

Table 554. Power Usage Power Cap Value

Name

Object ID

Description

Syntax

Access powerUsagePowerCapValue

1.3.6.1.4.1.674.10892.1.600.60.1.19

Defines the system power cap value (in Watts).

DellUnsigned32BitRange

Read-only

Table 555. Power Usage Instantaneous Headroom

Name

Object ID

Description

Syntax

Access powerUsageInstantaneousHeadroom

1.3.6.1.4.1.674.10892.1.600.60.1.20

Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw.

DellUnsigned32BitRange

Read-only

Table 556. Power Usage Peak Headroom

Name powerUsagePeakHeadroom

Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.21

126 Server Administrator Group

Table 556. Power Usage Peak Headroom (continued)

Description

Syntax

Access

Defines the system peak headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus peak power draw.

DellUnsigned32BitRange

Read-only

Power Profile Table

Table 557. Power Profile Table

Name

Object ID

Description

Syntax

Access powerProfileTable

1.3.6.1.4.1.674.10892.1.600.70

Defines the Power Profile Table.

SEQUENCE OF PowerProfileTableEntry

Not accessible

Table 558. Power Profile Table Entry

Name

Object ID

Description

Syntax

Access

Index powerProfileTableEntry

1.3.6.1.4.1.674.10892.1.600.70.1

Defines the Power Profile Table Entry.

PowerProfileTableEntry

Not accessible powerProfileChassisIndex , powerProfileIndex

Table 559. Power Profile Chassis Index

Name

Object ID

Description

Syntax

Access powerProfileChassisIndex

1.3.6.1.4.1.674.10892.1.600.70.1.1

Defines the index (one-based) of the associated chassis.

DellObjectRange

Read-only

Table 560. Power Profile Index

Name

Object ID

Description

Syntax

Access powerProfileIndex

1.3.6.1.4.1.674.10892.1.600.70.1.2

Defines the index (one-based) of the power profile information.

DellObjectRange

Read-only

Table 561. Power Profile Supported Profiles

Name

Object ID

Description

Syntax powerProfileSupportedProfiles

1.3.6.1.4.1.674.10892.1.600.70.1.3

Defines the supported power profiles.

DellPowerProfileType

Server Administrator Group 127

Table 561. Power Profile Supported Profiles (continued)

Access Read-only

Table 562. Power Profile Setting

Name

Object ID

Description

Syntax

Access powerProfileSetting

1.3.6.1.4.1.674.10892.1.600.70.1.4

Defines the power profile setting.

DellPowerProfileType

Read-only

Table 563. Power Profile Custom CPU Management Capabilities

Name

Object ID

Description

Syntax

Access powerProfileCustomCPUManagementCapabilities

1.3.6.1.4.1.674.10892.1.600.70.1.5

Defines the custom CPU power and performance management capabilities that are available for the Custom power profile.

DellCPUPowerPerformanceManagementType

Read-only

Table 564. Power Profile Custom CPU Management Setting

Name

Object ID

Description

Syntax

Access powerProfileCustomCPUManagementSetting

1.3.6.1.4.1.674.10892.1.600.70.1.6

Defines the custom CPU power and performance management setting for the Custom power profile.

DellCPUPowerPerformanceManagementType

Read-only

Table 565. Power Profile Custom Memory Management Capabilities

Name

Object ID

Description

Syntax

Access powerProfileCustomMemoryManagementCapabilities

1.3.6.1.4.1.674.10892.1.600.70.1.7

Defines the custom memory power and performance management capabilities that are available for the Custom power profile.

DellMemoryPowerPerformanceManagementType

Read-only

Table 566. Power Profile Custom Memory Management Capabilities

Name

Object ID

Description

Syntax

Access powerProfileCustomMemoryManagementSetting

1.3.6.1.4.1.674.10892.1.600.70.1.8

Defines the custom memory power and performance management setting for the

Custom power profile.

DellMemoryPowerPerformanceManagementType

Read-only

Table 567. Power Profile Custom Fan Management Capabilities

Name powerProfileCustomFanManagementCapabilities

128 Server Administrator Group

Table 567. Power Profile Custom Fan Management Capabilities (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.600.70.1.9

Defines the custom fan power and performance management capabilities that are available for the Custom power profile.

DellFanPowerPerformanceManagementType

Read-only

Table 568. Power Profile Custom Fan Management Setting

Name

Object ID

Description

Syntax

Access powerProfileCustomFanManagementSetting

1.3.6.1.4.1.674.10892.1.600.70.1.10

Defines the custom fan power and performance management setting for the Custom power profile.

DellFanPowerPerformanceManagementType

Read-only

Power Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 569. Power Supply State Capabilities Unique

Variable Name : DellPowerSupplyStateCapabilitiesUnique

Data Type : Integer

Possible Data Values unknown(1) onlineCapable(2) notReadyCapable(4)

Meaning of Data Value

The power supply’s capabilities are unknown.

The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).

The power supply’s capabilities are not ready.

Table 570. Power Supply State Settings Unique

Variable Name : DellPowerSupplyStateSettingsUnique

Data Type : Integer

Possible Data Values unknown(1) onLine(2)

Meaning of Data Value

The power supply’s capabilities are unknown.

The power supply’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).

notReady(4) fanFailure(8) onlineAndFanFailure(10)

The power supply’s state is not ready.

The power supply fan has failed.

The power supply is online and indicating that its fan is not working.

The power supply is indicating that it is on.

powerSupplyIsON(16) powerSupplyIsOk(32) acSwitchIsON(64) onlineandAcSwitchIsON (66)

The power supply is indicating that it is OK.

The power supply is indicating that the AC power switch is on.

The power supply is online and indicating that the AC power supply switch capability is activated.

Server Administrator Group 129

Table 570. Power Supply State Settings Unique (continued) acPowerIsON(128) onlineAndAcPowerIsON (130) onlineAndPredictiveFail ure(210) acPowerAndSwitchAreOn PowerSupplyIsOnIsOkAnd

Online(242)

The power supply is indicating that the AC power is on.

The power supply is online and indicating that the AC power is on.

The power supply is online and indicating that it has a problem.

The power supply is online and OK.

Table 571. Power Supply Type Definitions

Variable Name : DellPowerSupplyType

Data Type : Integer

Possible Data Values powerSupplyTypeIsOther(1) powerSupplyTypeIsUnknown(2) powerSupplyTypeIsLinear(3) powerSupplyTypeIsSwitching(4) powerSupplyTypeIsBattery(5) powerSupplyTypeIsUPS(6) powerSupplyTypeIsConverter(7) powerSupplyTypeIsRegulator(8) powerSupplyTypeIsAC(9) powerSupplyTypeIsDC(10) powerSupplyTypeIsVRM(11)

Meaning of Data Value

The power supply type is not one of the following:

The power supply type is unknown (not known or not monitored).

The power supply type is a linear power supply.

The power supply type is a switching power supply.

The power supply type is a battery.

The power supply type is an uninterruptable power supply.

The power supply type is a power converter power supply.

The power supply type is a regulator power supply.

The power supply type is an AC power supply.

The power supply type is a DC power supply.

The power supply type is a voltage regulator module (VRM) power supply.

Table 572. Power Supply Sensor State

Variable Name : DellPowerSupplySensorState

Data Type : Integer

Possible Data Values presenceDetected(1) psFailureDetected(2) predictiveFailure(4) psACLost(8) acLostOrOutOfRange(16) acOutOfRangeButPresent(32) configurationError(64)

Meaning of Data Value

The power supply’s presence is detected.

The power supply failure is detected.

The power supply sensor detects predictive failure

The power supply’s AC power is lost.

The power supply’s AC power is lost or out of range.

The power supply’s AC power is present, but it is out of range.

The power supply sensor detects a configuration error.

Table 573. Power Supply Configuration Error Type

Variable Name : DellPowerSupplyConfigurationErrorType

Data Type : Integer

Possible Data Values Meaning of Data Value

130 Server Administrator Group

Table 573. Power Supply Configuration Error Type (continued) vendorMismatch(1) revisionMismatch(2) processorMissing(3)

The power supply configuration error type is vendor mismatch.

The power supply configuration error type is revision mismatch.

The power supply configuration error type is processor missing.

Table 574. Voltage Probe Type

Variable Name : DellVoltageType

Data Type : Integer

Possible Data Values voltageProbeTypeIsOther(1) voltageProbeTypeIsUnknown(2) voltageProbeTypeIs1Point5Volt (3) voltageProbeTypeIs3Point3Volt (4) voltageProbeTypeIs5Volt(5) voltageProbeTypeIsMinus5Volt (6) voltageProbeTypeIs12Volt(7) voltageProbeTypeIsMinus12Volt (8) voltageProbeTypeIsIO(9) voltageProbeTypeIsCore(10) voltageProbeTypeIsFLEA(11) voltageProbeTypeIsBattery(12) voltageProbeTypeIsTerminator (13) voltageProbeTypeIs2Point5Volt (14) voltageProbeTypeIsGTL(15) voltageProbeTypeIsDiscrete(16)

Meaning of Data Value

The voltage probe type is not one of the following:

The voltage probe type is unknown (not known or not monitored).

The voltage probe type is a 1.5-volt (V) probe.

The voltage probe type is a 3.3-V probe.

The voltage probe type is a 5-V probe.

The voltage probe type is a –5-V probe.

The voltage probe type is a 12-V probe.

The voltage probe type is a –12-V probe.

The voltage probe type is an I/O volt probe.

The voltage probe type is a core volt probe.

The voltage probe type is a FLEA (standby) volt probe.

The voltage probe type is a battery volt probe.

The voltage probe type is a SCSI termination volt probe.

The voltage probe type is a 2.5-V probe.

The voltage probe type is a ground termination logic (GTL) probe.

The voltage probe type is a voltage probe with discrete reading.

Table 575. Voltage Probe Discrete Reading

Variable Name : DellVoltageDiscreteReading

Data Type : Integer

Possible Data Values voltageIsGood(1) voltageIsBad(2)

Table 576. Amperage Probe Definitions

Variable Name : DellAmperageType

Data Type : Integer

Possible Data Values

Meaning of Data Value

The voltage probe discrete reading is good.

The voltage probe discrete reading is bad.

Meaning of Data Value

Server Administrator Group 131

Table 576. Amperage Probe Definitions (continued) amperageProbeTypeIsOther(1) amperageProbeTypeIsUnknown(2) amperageProbeTypeIs1Point5Volt(3) amperageProbeTypeIs3Point3volt(4) amperageProbeTypeIs5Volt(5) amperageProbeTypeIsMinus5Volt(6) amperageProbeTypeIs12Volt(7) amperageProbeTypeIsMinus12Volt(8) amperageProbeTypeIsIO(9) amperageProbeTypeIsCore(10) amperageProbeTypeIsFLEA(11) amperageProbeTypeIsBattery(12) amperageProbeTypeIsTerminator(13) amperageProbeTypeIs2Point5Volt(14) amperageProbeTypeIsGTL(15) amperageProbeTypeIsDiscrete(16) amperageProbeTypeIsPowerSupplyAmps(23) amperageProbeTypeIsPowerSupplyWatts (24) amperageProbeTypeIsSystemAmps(25) amperageProbeTypeIsSystemWatts(26)

The amperage probe type is not one of the following:

The amperage probe type is unknown (not known or not monitored).

The amperage probe type is a 1.5-ampere (A) probe.

The amperage probe type is a 3.3-A probe.

The amperage probe type is a 5-A probe.

The amperage probe type is a –5-A probe.

The amperage probe type is a 12-A probe.

The amperage probe type is a –12-A probe.

The amperage probe type is an I/O amperage probe.

The amperage probe type is a core amperage probe.

The amperage probe type is a FLEA (standby) amperage probe.

The amperage probe type is a battery amperage probe.

The amperage probe type is a Small Computer System

Interface (SCSI) termination amperage probe.

The amperage probe type is a 2.5-V amperage probe.

The amperage probe type is a Gunning Transceiver Logic

(GTL) probe.

The amperage probe type is an amperage probe with discrete reading.

The amperage probe type is power supply probe with reading in Amperes.

The amperage probe type is power supply probe with reading in Watts.

The amperage probe type is system probe with reading in

Amperes.

The amperage probe type is system probe with reading in

Watts.

Table 577. Amperage Probe Discrete Reading

Variable Name : DellAmperageDiscreteReading

Data Type : Integer

Possible Data Values amperageIsGood(1) amperageIsBad(2)

Meaning of Data Value

The amperage probe discrete reading is good.

The amperage probe discrete reading is bad.

Table 578. AC Power Switch Capabilities

Variable Name : DellACPowerSwitchCapabilities

Data Type : Integer

Possible Data Values unknownCapabilities(1) inputSourceCord1NoReturnCapable(2)

Meaning of Data Value

The AC power switch’s capabilities are unknown.

Input source is AC power cord 1, with no return.

132 Server Administrator Group

Table 578. AC Power Switch Capabilities (continued) inputSourceCord1ReturnCapable(4) inputSourceCord2NoReturnCapable(8) inputSourceCord2ReturnCapable(16) inputSourceSharedCapable(32)

Input source is AC power cord 1, with return.

Input source is AC power cord 2, with no return.

Input source is AC power cord 2, with return.

Input source is shared.

Table 579. AC Power Switch Settings

Variable Name : DellACPowerSwitchSettings

Data Type : Integer

Possible Data Values unknown(1) inputSourceCord1NoReturn(2) inputSourceCord1Return(4) inputSourceCord2NoReturn(8) inputSourceCord2Return(16) inputSourceShared(32)

Meaning of Data Value

The AC power switch’s settings are unknown.

Input source is AC power cord 1, with no return.

Input source is AC power cord 1, with return.

Input source is AC power cord 2, with no return.

Input source is AC power cord 2, with return.

Input source is shared.

Table 580. AC Power Switch Redundancy Mode

Variable Name : DellACPowerSwitchRedundancyMode

Data Type : Integer

Possible Data Values nonRedundant(1) redundant(2)

Meaning of Data Value

The AC power switch is not expecting redundancy.

The AC power switch is expecting redundancy.

Table 581. AC Power Cord State Capabilities

Variable Name : DellACPowerCordStateCapabilities

Data Type : Integer

Possible Data Values unknown(1) onlineCapable(2) notReadyCapable(4)

Meaning of Data Value

The AC power cord’s capabilities are unknown.

The AC power cord can be disabled (offline) or enabled

(online).

The AC power cord’s capabilities are not ready.

Table 582. AC Power Cord State Settings

Variable Name : DellACPowerCordStateSettings

Data Type : Integer

Possible Data Values unknown(1) online(2) notReady(4) acPowerCordHasPower (8)

Meaning of Data Value

The AC power cord’s state is unknown.

The AC power cord’s state is disabled (offline) 0 or enabled

(online) 1.

The AC power cord’s state is not ready.

The AC power cord has power.

Server Administrator Group 133

Table 582. AC Power Cord State Settings (continued) acPowerCordIsActive Source(16) The AC power cord is the active source of AC power.

Table 583. Battery Reading

Variable Name : DellBatteryReading

Data Type : Integer

NOTE: These values are bit masks, so combination values are possible.

Possible Data Values predictiveFailure(1) failed(2) presenceDetected(4)

Meaning of Data Value

Battery sensor detects predictive failure.

Battery has failed.

Battery presence is detected.

Table 584. Power Cap Capabilities

Variable Name : DellPowerCapCapabilities

Data Type : Integer

NOTE: These values are bit masks, so combination values are possible.

Possible Data Values none(0) enable(1) disable(2)

Meaning of Data Value

No power cap capabilities are available.

Power cap can be enabled.

Power cap can be disabled.

Table 585. Power Cap Setting

Variable Name : DellPowerCapSetting

Data Type : Integer

Possible Data Values disabled(0) enabled(1)

Meaning of Data Value

Power cap is disabled.

Power cap is enabled.

Table 586. Power Profile Type

Variable Name : DellPowerProfileType

Data Type : Integer

NOTE: These values are bit masks, so combination values are possible.

Possible Data Values maxPerformance(1) osControl(2) activePowerController(4) custom(8)

Meaning of Data Value

Power profile type is Maximum Performance.

Power profile type is OS control.

Power profile type is Active Power Controller.

Power profile type is Custom.

Table 587. CPU Power Performance Management Type

Variable Name : DellCPUPowerPerformanceManagementType

Data Type : Integer

134 Server Administrator Group

Table 587. CPU Power Performance Management Type (continued)

NOTE:

These values are bit masks, so combination values are possible.

Possible Data Values maxPerformance(1)

Meaning of Data Value

CPU power and performance management type is Maximum

Performance.

minPower(2) osDBPM(4) systemDBPM(8)

CPU power and performance management type is Minimum

Power.

CPU power and performance management type is OS Demand

Based Power Management.

CPU power and performance management type is System

Demand Based Power Management.

Table 588. Memory Power Performance Management Type

Variable Name : DellMemoryPowerPerformanceManagementType

Data Type : Integer

NOTE:

These values are bit masks, so combination values are possible.

Possible Data Values maxPerformance(1) mhz1333(2) mhz1067(4)

Meaning of Data Value

Memory power and performance management type is

Maximum Performance.

Memory power and performance is 1333 MHz. .

Memory power and performance is 1067 MHz.

mhz800(8) minPower(16)

Memory power and performance is 800 MHz.

Memory power and performance management type is

Minimum Power.

Table 589. Fan Power Performance Management Type

Variable Name : DellFanPowerPerformanceManagementType

Data Type : Integer

NOTE:

These values are bit masks, so combination values are possible.

Possible Data Values Meaning of Data Value maxPerformance(1) minPower(2)

Fan power and performance management type is Maximum

Performance.

Fan power and performance management type is Minimum

Power.

Thermal Group

The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes.

Server Administrator Group 135

Thermal Group Tables

The following management information base (MIB) tables define the objects in the Thermal Group:

Cooling Unit Table

Cooling Device Table

Temperature Probe Table

Cooling Unit Table

Table 590. Cooling Unit Table

Name

Object ID

Description

Syntax

Access coolingUnitTable

1.3.6.1.4.1.674.10892.1.700.10

Defines the Cooling Unit Table.

TableEntry

Not accessible

Table 591. Cooling Unit Table Entry

Name coolingUnitTableEntry

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.700.10.1

Defines the Cooling Unit Table entry.

TableEntry

Not accessible coolingUnitchassisIndex

, coolingUnitIndex

Table 592. Cooling Unit Chassis Index

Name

Object ID

Description

Syntax

Access coolingUnitchassisIndex

1.3.6.1.4.1.674.10892.1.700.10.1.1

Defines the index (one-based) of this chassis.

TableEntry

Read-only

Table 593. Cooling Unit Index

Name

Object ID

Description

Syntax

Access coolingUnitIndex

1.3.6.1.4.1.674.10892.1.700.10.1.2

Defines the index (one-based) of cooling units.

DellObjectRange

Read-only

Table 594. Cooling Unit State Capabilities

Name coolingUnitStateCapabilties

136 Server Administrator Group

Table 594. Cooling Unit State Capabilities (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.700.10.1.3

Defines the capabilities of the cooling unit.

DellStateCapabilities

Read-only

Table 595. Cooling Unit State Settings

Name

Object ID

Description

Syntax

Access coolingUnitStateSettings

1.3.6.1.4.1.674.10892.1.700.10.1.4

Defines the state and settings of the cooling unit.

DellStateSettings

Read-only

Table 596. Cooling Unit Redundancy Status

Name

Object ID

Description

Syntax

Access coolingUnitRedundancyStatus

1.3.6.1.4.1.674.10892.1.700.10.1.5

Defines the redundancy status of the cooling unit.

DellStatusRedundancy

Read-only

Table 597. Cooling Device Count For Redundancy

Name

Object ID

Description

Syntax

Access coolingDeviceCountForRedundancy

1.3.6.1.4.1.674.10892.1.700.10.1.6

Defines the total number of cooling devices required for this cooling unit to have redundancy.

DellObjectRange

Read-only

Table 598. Cooling Unit Name

Name

Object ID

Description

Syntax

Access coolingUnitName

1.3.6.1.4.1.674.10892.1.700.10.1.7

Defines the cooling unit name in this chassis.

DellString

Read-only

Table 599. Cooling Unit Status

Name

Object ID

Description

Syntax

Access coolingUnitStatus

1.3.6.1.4.1.674.10892.1.700.10.1.8

Defines the status of the cooling unit in this chassis.

DellStatus

Read-only

Server Administrator Group 137

Cooling Device Table

Table 600. Cooling Device Table

Name

Object ID

Description

Syntax

Access coolingDeviceTable

1.3.6.1.4.1.674.10892.1.700.12

Defines the Cooling Device Table.

CoolingDeviceTableEntry

Not accessible

Table 601. Cooling Device Table Entry

Name

Object ID

Description

Syntax

Access

Index coolingDeviceTableEntry

1.3.6.1.4.1.674.10892.1.700.12.1

Defines the Cooling Device Table entry.

CoolingDeviceTableEntry

Not accessible cooling DevicechassisIndex

, coolingDeviceIndex

Table 602. Cooling Device Chassis Index

Name

Object ID

Description

Syntax

Access coolingDevicechassisIndex

1.3.6.1.4.1.674.10892.1.700.12.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 603. Cooling Device Index

Name

Object ID

Description

Syntax

Access coolingDeviceIndex

1.3.6.1.4.1.674.10892.1.700.12.1.2

Defines the index of cooling devices in this chassis.

DellObjectRange

Read-only

Table 604. Cooling Device State Capabilities

Name

Object ID

Description

Syntax

Access coolingDeviceStateCapabilities

1.3.6.1.4.1.674.10892.1.700.12.1.3

Defines the capabilities of the cooling device.

DellStateCapabilities

Read-only

138 Server Administrator Group

Table 605. Cooling Device State Settings

Name

Object ID

Description

Syntax

Access coolingDeviceStateSettings

1.3.6.1.4.1.674.10892.1.700.12.1.4

Defines the state and settings of the cooling device.

DellStateSettings

Read-only

Table 606. Cooling Device Status

Name

Object ID

Description

Syntax

Access coolingDeviceStatus

1.3.6.1.4.1.674.10892.1.700.12.1.5

Defines the status of the cooling device.

DellStatusProbe

Read-only

Table 607. Cooling Device Reading

Name

Object ID

Description coolingDeviceReading

1.3.6.1.4.1.674.10892.1.700.12.1.6

Defines either the cooling device’s speed in revolutions per minute (RPM), or the off/on value of the fan.

When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute.

Syntax

Access

DellSigned32BitRange

Read-only

Table 608. Cooling Device Type

Name

Object ID

Description

Syntax

Access coolingDeviceType

1.3.6.1.4.1.674.10892.1.700.12.1.7

Defines the cooling device type.

DellCoolingDeviceType (

Cooling Device Type

)

Read-only

Table 609. Cooling Device Location Name

Name

Object ID

Description

Syntax

Access coolingDeviceLocationName

1.3.6.1.4.1.674.10892.1.700.12.1.8

Defines the location of the cooling device in this chassis.

DellString

Read-only

Table 610. Cooling Device Upper Nonrecoverable Threshold

Name coolingDeviceUppernonrecoverableThreshold

Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9

Server Administrator Group 139

Table 610. Cooling Device Upper Nonrecoverable Threshold (continued)

Description

Syntax

Access

Defines the value of the fan’s upper nonrecoverable threshold.

DellSigned32BitRange

Read-only

Table 611. Cooling Device Upper Critical Threshold

Name

Object ID

Description

Syntax

Access coolingDeviceUpperCriticalThreshold

1.3.6.1.4.1.674.10892.1.700.12.1.10

Defines the value of the fan’s upper critical threshold.

DellSigned32BitRange

Read-only

Table 612. Cooling Device Upper Noncritical Threshold

Name

Object ID

Description

Syntax

Access coolingDeviceUpperNonCriticalThreshold

1.3.6.1.4.1.674.10892.1.700.12.1.11

Defines the user-assigned value of the fan’s upper noncritical threshold.

DellSigned32BitRange

Read-only

Table 613. Cooling Device Lower Noncritical Threshold

Name

Object ID

Description

Syntax

Access coolingDeviceLowerNonCriticalThreshold

1.3.6.1.4.1.674.10892.1.700.12.1.12

Defines the user-assigned value of the fan’s lower noncritical threshold.

DellSigned32BitRange

Read-only

Table 614. Cooling Device Lower Critical Threshold

Name

Object ID

Description

Syntax

Access coolingDeviceLowerCriticalThreshold

1.3.6.1.4.1.674.10892.1.700.12.1.13

Defines the value of the fan’s lower critical threshold.

DellSigned32BitRange

Read-only

Table 615. Cooling Device Lower Nonrecoverable Threshold

Name

Object ID

Description

Syntax

Access coolingDeviceLowerNonRecoverableThreshold

1.3.6.1.4.1.674.10892.1.700.12.1.14

Defines the value of the fan’s lower nonrecoverable threshold.

DellSigned32BRead-onlyitRange

Read-only

Table 616. Cooling Device Cooling Unit Index Reference

Name

Object ID coolingDevicecoolingUnitIndexReference

1.3.6.1.4.1.674.10892.1.700.12.1.15

140 Server Administrator Group

Table 616. Cooling Device Cooling Unit Index Reference (continued)

Description

Syntax

Access

Defines the index for the associated system cooling unit in this chassis.

DellObjectRange

Read-only

Table 617. Cooling Device Subtype

Name

Object ID

Description

Syntax

Access coolingDeviceSubType

1.3.6.1.4.1.674.10892.1.700.12.1.16

Defines the cooling device subtype.

DellCoolingDeviceSubType ( Cooling Device Subtype

)

Read-only

Table 618. Cooling Device Probe Capabilities

Name

Object ID

Description

Syntax

Access coolingDeviceProbeCapabilities

1.3.6.1.4.1.674.10892.1.700.12.1.17

Defines the probe capabilities of the cooling device.

DellProbeCapabilities

Read-only

Table 619. Cooling Device Discrete Reading

Name

Object ID

Description coolingDeviceDiscreteReading

1.3.6.1.4.1.674.10892.1.700.12.1.18

Defines the reading for a voltage probe of type coolingDeviceSubTypeIsDiscrete.

When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the discrete reading for the cooling device.

Syntax

Access

DellCoolingDeviceDiscreteReading ( Cooling Device Discrete Reading

)

Read-only

Temperature Probe Table

Table 620. Temperature Probe Table

Name

Object ID

Description

Syntax

Access temperatureProbeTable

1.3.6.1.4.1.674.10892.1.700.20

Defines the Temperature Probe Table.

TemperatureProbeTableEntry

Not accessible

Table 621. Temperature Probe Table Entry

Name

Object ID

Description temperatureProbeTableEntry

1.3.6.1.4.1.674.10892.1.700.20.1

Defines the Temperature Probe Table entry.

Server Administrator Group 141

Table 621. Temperature Probe Table Entry (continued)

Syntax

Access

Index

TemperatureProbeTableEntry

Not accessible temperatureProbechassisIndex

, temperatureProbeIndex

Table 622. Temperature Probe Chassis Index

Name

Object ID

Description

Syntax

Access temperatureProbechassisIndex

1.3.6.1.4.1.674.10892.1.700.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 623. Temperature Probe Index

Name

Object ID

Description

Syntax

Access temperatureProbeIndex

1.3.6.1.4.1.674.10892.1.700.20.1.2

Defines the index of temperature probes in this chassis.

DellObjectRange

Read-only

Table 624. Temperature Probe State Capabilities

Name

Object ID

Description

Syntax

Access temperatureProbeStateCapabilities

1.3.6.1.4.1.674.10892.1.700.20.1.3

Defines the capabilities of the temperature probe.

DellStateCapabilities

Read-only

Table 625. Temperature Probe State Settings

Name

Object ID

Description

Syntax

Access temperatureProbeStateSettings

1.3.6.1.4.1.674.10892.1.700.20.1.4

Defines the state and settings of the temperature probe.

DellStateSettings

Read-only

Table 626. Temperature Probe Status

Name

Object ID

Description

Syntax

Access temperatureProbeStatus

1.3.6.1.4.1.674.10892.1.700.20.1.5

Defines the status of the temperature probe in tenths of degrees Celsius.

DellStatusProbe

Read-only

142 Server Administrator Group

Table 627. Temperature Probe Reading

Name

Object ID

Description temperatureProbeReading

1.3.6.1.4.1.674.10892.1.700.20.1.6

Defines the value of the temperature probe.

When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in tenths of degrees Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute.

Syntax

Access

DellSigned32BitRange

Read-only

Table 628. Temperature Probe Type

Name

Object ID

Description

Syntax

Access temperatureProbeType

1.3.6.1.4.1.674.10892.1.700.20.1.7

Defines the temperature probe type.

DellTemperatureProbeType (

Temperature Probe Type

)

Read-only

Table 629. Temperature Probe Location Name

Name

Object ID

Description

Syntax

Access temperatureProbeLocationName

1.3.6.1.4.1.674.10892.1.700.20.1.8

Defines the location of the temperature probe in this chassis.

DellString

Read-only

Table 630. Temperature Probe Upper Nonrecoverable Threshold

Name

Object ID

Description

Syntax

Access temperatureProbeUpperNonRecoverableThreshold

1.3.6.1.4.1.674.10892.1.700.20.1.9

Defines the value of the temperature probe’s upper nonrecoverable threshold.

DellSigned32BitRange

Read-only

Table 631. Temperature Probe Upper Critical Threshold

Name

Object ID

Description

Syntax

Access temperatureProbeUpperCriticalThreshold

1.3.6.1.4.1.674.10892.1.700.20.1.10

Defines the value of the temperature probe’s upper critical threshold.

DellSigned32BitRange

Read-only

Table 632. Temperature Probe Upper Noncritical Threshold

Name

Object ID

Description temperatureProbeUpperNonCriticalThreshold

1.3.6.1.4.1.674.10892.1.700.20.1.11

Defines the user-assigned value of the temperature probe’s upper noncritical threshold.

Server Administrator Group 143

Table 632. Temperature Probe Upper Noncritical Threshold (continued)

Syntax

Access

DellSigned32BitRange

Read-only

Table 633. Temperature Probe Lower Noncritical Threshold

Name

Object ID

Description

Syntax

Access temperatureProbeLowerNonCriticalThreshold

1.3.6.1.4.1.674.10892.1.700.20.1.12

Defines the user-assigned value of the temperature probe’s lower noncritical threshold.

DellSigned32BitRange

Read-only

Table 634. Temperature Probe Lower Critical Threshold

Name

Object ID

Description

Syntax

Access temperatureProbeLowerCriticalThreshold

1.3.6.1.4.1.674.10892.1.700.20.1.13

Defines the value of the temperature probe’s lower critical threshold.

DellSigned32BitRange

Read-only

Table 635. Temperature Probe Lower Nonrecoverable Threshold

Name

Object ID

Description

Syntax

Access temperatureProbeLowerNonRecoverableThreshold

1.3.6.1.4.1.674.10892.1.700.20.1.14

Defines the value of the temperature probe’s lower nonrecoverable threshold.

DellSigned32BitRange

Read-only

Table 636. Temperature Probe Probe Capabilities

Name

Object ID

Description

Syntax

Access temperatureProbeProbeCapabilities

1.3.6.1.4.1.674.10892.1.700.20.1.15

Defines the probe capabilities of the temperature probe.

DellProbeCapabilities

Read-only

Table 637. Temperature Probe Discrete Reading

Name temperatureProbeDiscreteReading

Object ID

Description

1.3.6.1.4.1.674.10892.1.700.20.1.16

Defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete.

When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.

Syntax

Access

DellTemperatureDiscreteReading ( Temperature Probe Discrete Reading

)

Read-only

144 Server Administrator Group

Thermal Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 638. Cooling Device Type

Variable Name : DellCoolingDeviceType

Data Type : Integer

Possible Data Values coolingDeviceTypeIsOther(1) coolingDeviceTypeIsUnknown(2) coolingDeviceTypeIsAFan(3) coolingDeviceTypeIsABlower(4) coolingDeviceTypeIsAChipFan(5) coolingDeviceTypeIsACabinetFan(6) coolingDeviceTypeIsAPowerSupplyFan(7) coolingDeviceTypeIsAHeatPipe(8) coolingDeviceTypeIsRefrigeration(9) coolingDeviceTypeIsActiveCooling(10) coolingDeviceTypeIsPassiveCooling(11)

Meaning of Data Value

The cooling device type is not one of the following:

The cooling device type is unknown (not known or not monitored).

The cooling device type is a fan.

The cooling device type is a centrifugal blower.

The cooling device type is a fan on an integrated circuit.

The cooling device type is a cabinet fan.

The cooling device type is a power supply fan.

The cooling device type is a heat pipe.

The cooling device type is an integrated refrigeration unit.

The cooling device type is an active cooling device.

The cooling device type is a passive cooling device.

Table 639. Cooling Device Subtype

Variable Name : DellCoolingDeviceSubType

Data Type : Integer

Possible Data Values Meaning of Data Value coolingDeviceSubTypeIsOther(1) coolingDeviceSubTypeIsUnknown(2)

The cooling device subtype is not one of the following:

The cooling device subtype is unknown (not known or not monitored).

coolingDeviceSubTypeIsAFanThatReads InRPM(3) The cooling device subtype is a fan that reads in RPMs.

coolingDeviceSubTypeIsAFanReadsONor OFF(4) coolingDeviceSubTypeIsAPowerSupply

FanThatReadsinRPM(5) coolingDeviceSubTypeIsAPowerSupply

FanThatReads- ONorOFF(6) coolingDeviceSubTypeIsDiscrete(16)

The cooling device subtype is a fan that reads 0 (off) or 1

(on).

The cooling device subtype is a power supply fan that reads in

RPMs.

The cooling device subtype is a power supply fan that reads 0

(off) or 1 (on).

The cooling device subtype is a cooling device with discrete reading.

Table 640. Cooling Device Discrete Reading

Variable Name : DellCoolingDeviceDiscreteReading .

Data Type : Integer

Possible Data Values Meaning of Data Value coolingDeviceIsGood(1) coolingDeviceIsBad(2)

The cooling device discrete reading is good.

The cooling device discrete reading is bad

Server Administrator Group 145

Table 641. Temperature Probe Type

Variable Name : DellTemperatureProbeType

Data Type : Integer

Possible Data Values temperatureProbeTypeIsOther(1) temperatureProbeTypeIsUnknown(2) temperatureProbeTypeIsAmbientESM(3) temperatureProbeTypeIsDiscrete(16)

Meaning of Data Value

The temperature probe subtype is not one of the following:

The temperature probe subtype is unknown (not known or not monitored).

The temperature probe is for ambient Embedded Systems

Management (ESM).

The temperature probe subtype is a temperature probe with discrete reading.

Table 642. Temperature Probe Discrete Reading

Variable Name : DellTemperatureDiscreteReading

Data Type : Integer

Possible Data Values temperatureIsGood(1) temperatureIsBad(2)

Meaning of Data Value

The temperature probe discrete reading is good.

The temperature probe discrete reading is bad.

Remote Flash BIOS Group

The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system.

The variables also define the capabilities of BIOS updates on the system.

Remote Flash BIOS Group Table

The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table.

Remote Flash BIOS Table

The following object sets up the Remote Flash BIOS Table:

Table 643. Remote Flash BIOS Table

Name

Object ID

Description

Syntax

Access remoteFlashBIOSTable

1.3.6.1.4.1.674.10892.1.900.10

Defines the Remote Flash BIOS Table.

RemoteFlashBIOSTableEntry

Not accessible

Table 644. Remote Flash BIOS Table Entry

Name

Object ID

Description

Syntax remoteFlashBIOSTableEntry

1.3.6.1.4.1.674.10892.1.900.10.1

Defines the Remote Flash BIOS Table entry.

RemoteFlashBIOSTableEntry

146 Server Administrator Group

Table 644. Remote Flash BIOS Table Entry (continued)

Access

Index

Not accessible remoteFlashBIOSchassisIndex , remoteFlashBIOSIndex

Table 645. Remote Flash BIOS Chassis Index

Name

Object ID

Description

Syntax

Access remoteFlashBIOSchassisIndex

1.3.6.1.4.1.674.10892.1.900.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 646. Remote Flash BIOS Index

Name remoteFlashBIOSIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.900.10.1.2

Defines the index to the remote BIOS update hardware on this system.

DellObjectRange

Read-only

Table 647. Remote Flash BIOS State Capabilities Unique

Name

Object ID

Description

Syntax

Access remoteFlashBIOSStateCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.900.10.1.3

Defines the capabilities of the remote BIOS update hardware on this system.

DellRemoteFlashBIOSStateCapabilitiesUnique (

Remote Flash BIOS State Capabilities

Unique

)

Read-only

Table 648. Remote Flash BIOS State Settings Unique

Name

Object ID

Description

Syntax

Access remoteFlashBIOSStateSettingsUnique

1.3.6.1.4.1.674.10892.1.900.10.1.4

Defines the state and settings of the remote BIOS update hardware on this system.

DellRemoteFlashBIOSStateSettingsUnique (

Remote Flash BIOS State Settings

)

Read-only

Table 649. Remote Flash BIOS Status

Name

Object ID

Description

Syntax

Access remoteFlashBIOSStatus

1.3.6.1.4.1.674.10892.1.900.10.1.5

Defines the status of the remote BIOS update hardware on this system.

DellRemoteFlashBIOSStateStatus

Read-only

Table 650. Remote Flash BIOS Last BIOS Date Name

Name

Object ID remoteFlashBIOSLastBIOSDateName

1.3.6.1.4.1.674.10892.1.900.10.1.6

Server Administrator Group 147

Table 650. Remote Flash BIOS Last BIOS Date Name (continued)

Description

Syntax

Access

Defines the date of the last BIOS update.

DellDateName

Read-only

Table 651. Remote Flash BIOS Completion Code

Name

Object ID

Description

Syntax

Access remoteFlashBIOSCompletionCode

1.3.6.1.4.1.674.10892.1.900.10.1.7

Defines the completion code of the last BIOS update.

DellRemoteFlashBIOSCompletionCode ( Remote Flash BIOS Completion Code

)

Read-only

Table 652. Remote Flash BIOS Minimum Contiguous Memory

Name

Object ID

Description

Syntax

Access remoteFlashBIOSMinimumContiguousMemory

1.3.6.1.4.1.674.10892.1.900.10.1.8

Defines the minimum size of contiguous memory required for remote BIOS update in kilobytes.

DellUnsigned32BitRange

Read-only

Remote Flash BIOS Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 653. Remote Flash BIOS State Capabilities Unique

Variable Name : DellRemoteFlashBIOSStateCapabilitiesUnique

Data Type : Integer

Possible Data Values Meaning of Data Value unknown(1) enableCapable(2) notReadyCapable(4) cancelCapable(8) enableAndCancelCapable(10)

The remote flash BIOS’s capabilities are unknown.

The remote flash BIOS can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).

The remote flash BIOS can be set to indicate not ready.

Flash of BIOS can be canceled.

Flash of BIOS can be enabled or canceled.

Table 654. Remote Flash BIOS State Settings

Variable Name : DellRemoteFlashBIOSStateSettingsUnique

Data Type : Integer

Possible Data Values unknown(1) enabled(2)

Meaning of Data Value

The remote flash BIOS’s capabilities are unknown.

notReady(4)

The remote flash BIOS update is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).

The remote flash BIOS’s state is not ready.

148 Server Administrator Group

Table 654. Remote Flash BIOS State Settings (continued) canceled(8) pending(16) other(32)

The remote flash BIOS has been canceled.

The remote flash BIOS update is pending.

The remote flash BIOS state/setting is not one of the previous values.

Table 655. Remote Flash BIOS Completion Code

Variable Name : DellRemoteFlashBIOSCompletionCode

Data Type : Integer

Possible Data Values Meaning of Data Value completionCodeIsOther(1) completionCodeIsUnknown(2)

The completion code status is not one of the following:

The completion code is unknown (not known or not monitored).

This completion code completed successfully.

completionCodeIsOK(3) completionCodeIsBadImage(4) completionCodeIsNoFileAccess(5) completionCodeIsNotReady(6)

This completion code is a bad flash BIOS image.

Flash BIOS could not be accessed.

Flash BIOS memory not ready.

completionCodeIsDisabled(7) completionCodeIsNoBattery(8) completionCodeIsNoChargedBattery(9) completionCodeIsNoExternalPower(10) completionCodeIsNo12VoltSet(11)

Flash BIOS is currently disabled.

A battery must be installed.

A fully charged battery must be installed.

An external power adapter must be connected.

12 volts (V) could not be set.

completionCodeIsNo12VoltRemoval(12) completionCodeIsFlashMemoryFailed (13) completionCodeIsGeneralFailure(14) completionCodeIsDataMiscompare(15) completionCodeIsNoImageFound(16) completionCodeIsNoUpdatePerformed (17)

12 V could not be removed.

A flash memory failure occurred.

A general failure occurred.

A data miscompare error occurred.

The flash BIOS image could not be found in memory.

No update operation has been performed.

Port Group

The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port.

Port Group Tables

The following MIB tables define objects in the Port Group:

Pointing Port Table

Keyboard Port Table

Processor Port Table

Memory Device Port Table

Monitor Port Table

Small Computer System Interface (SCSI) Port Table

Parallel Port Table

Server Administrator Group 149

Serial Port Table

Universal Serial Bus (USB) Port Table

Pointing Port Table

Table 656. Pointing Port Table

Name

Object ID

Description

Syntax

Access pointingPortTable

1.3.6.1.4.1.674.10892.1.1000.10

Defines the Pointing Port Table.

IntegerPointingPortTableEntry

Not accessible

Table 657. Pointing Port Table Entry

Name

Object ID

Description

Syntax

Access

Index pointingPortTableEntry

1.3.6.1.4.1.674.10892.1.1000.10.1

Defines the Pointing Port Table entry.

PointingPortTableEntry

Not accessible pointingPortchassisIndex

, pointingPortIndex

Table 658. Pointing Port Chassis Index

Name

Object ID

Description

Syntax

Access pointingPortchassisIndex

1.3.6.1.4.1.674.10892.1.1000.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 659. Pointing Port Index

Name

Object ID

Description

Syntax

Access pointingPortIndex

1.3.6.1.4.1.674.10892.1.1000.10.1.2

Defines the index of the pointing ports in this chassis.

DellObjectRange

Read-only

Table 660. Pointing Port State Capabilities

Name

Object ID

Description

Syntax pointingPortStateCapabilities

1.3.6.1.4.1.674.10892.1.1000.10.3

Defines the capabilities of the pointing port.

DellStateCapabilities

150 Server Administrator Group

Table 660. Pointing Port State Capabilities (continued)

Access Read-only

Table 661. Pointing Port State Settings

Name

Object ID

Description

Syntax

Access pointingPortStateSettings

1.3.6.1.4.1.674.10892.1.1000.10.4

Defines the state and settings of the pointing port.

DellStateSettings

Read-only

Table 662. Pointing Port Status

Name

Object ID

Description

Syntax

Access pointingPortStatus

1.3.6.1.4.1.674.10892.1.1000.10.5

Defines the status of the pointing port.

DellStatus

Read-only

Table 663. Pointing Port Security State

Name pointingPortSecurityState

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.10.6

Defines the security settings of the pointing port.

DellPortSecurityState

Read-only

Table 664. Pointing Port Connector Type

Name

Object ID

Description

Syntax

Access pointingPortConnectorType

1.3.6.1.4.1.674.10892.1.1000.10.7

Defines the connector type of the pointing port.

DellPointingPortConnectorType (See

Pointing Port Connector Type )

Read-only

Table 665. Pointing Port Name

Name

Object ID

Description

Syntax

Access pointingPortName

1.3.6.1.4.1.674.10892.1.1000.10.8

Defines the name of the pointing port.

DellString

Read-only

Table 666. Pointing Port BIOS Connector Type

Name

Object ID

Description

Syntax pointingPortBIOSConnectorType

1.3.6.1.4.1.674.10892.1.1000.10.9

Defines the basic input/output system (BIOS) connector type of the pointing port.

DellGenericPortConnectorType

Server Administrator Group 151

Table 666. Pointing Port BIOS Connector Type (continued)

Access Read-only

Keyboard Port Table

Table 667. Keyboard Port Table

Name keyboardPortTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.20

Defines the Keyboard Port Table.

IntegerKeyboardPortTableEntry

Not accessible

Table 668. Keyboard Port Table Entry

Name

Object ID

Description

Syntax

Access

Index keyboardPortTableEntry

1.3.6.1.4.1.674.10892.1.1000.20.1

Defines the Keyboard Port Table entry.

KeyboardPortTableEntry

Not accessible keyboardPortchassisIndex

, keyboardPortIndex

Table 669. Keyboard Port Chassis Index

Name keyboardPortchassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 670. Keyboard Port Index

Name

Object ID

Description

Syntax

Access keyboardPortIndex

1.3.6.1.4.1.674.10892.1.1000.20.1.2

Defines the index of the keyboard ports in this chassis.

DellObjectRange

Read-only

Table 671. Keyboard Port State Capabilities

Name

Object ID

Description

Syntax keyboardPortStateCapabilities

1.3.6.1.4.1.674.10892.1.1000.20.1.3

Defines the capabilities of the keyboard port.

DellStateCapabilities

152 Server Administrator Group

Table 671. Keyboard Port State Capabilities (continued)

Access Read-only

Table 672. Keyboard Port State Settings

Name

Object ID

Description

Syntax

Access keyboardPortStateSettings

1.3.6.1.4.1.674.10892.1.1000.20.1.4

Defines the state and settings of the keyboard port.

DellStateSettings

Read-only

Table 673. Keyboard Port Status

Name

Object ID

Description

Syntax

Access keyboardPortStatus

1.3.6.1.4.1.674.10892.1.1000.20.1.5

Defines the status of the keyboard port.

DellStatus

Read-only

Table 674. Keyboard Port Security State

Name keyboardPortSecurityState

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.20.1.6

Defines the security settings of the keyboard port.

DellPortSecurityState

Read-only

Table 675. Keyboard Port Connector Type

Name

Object ID

Description

Syntax

Access keyboardPortConnectorType

1.3.6.1.4.1.674.10892.1.1000.20.1.7

Defines the connector type of the keyboard port.

DellKeyboardPortConnectorType (See

Keyboard Port Connector Types

)

Read-only

Table 676. Keyboard Port Name

Name

Object ID

Description

Syntax

Access keyboardPortName

1.3.6.1.4.1.674.10892.1.1000.20.1.8

Defines the name of the keyboard port.

DellString

Read-only

Table 677. Keyboard Port BIOS Connector Type

Name

Object ID

Description

Syntax keyboardPortBIOSConnectorType

1.3.6.1.4.1.674.10892.1.1000.20.1.9

Defines the BIOS connector type of the keyboard port.

DellGenericPortConnectorType

Server Administrator Group 153

Table 677. Keyboard Port BIOS Connector Type (continued)

Access Read-only

Processor Port Table

Table 678. Processor Port Table

Name processorPortTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.30

Defines the Processor Port Table.

IntegerProcessorPortTableEntry

Not accessible

Table 679. Processor Port Table Entry

Name

Object ID

Description

Syntax

Access

Index processorPortTableEntry

1.3.6.1.4.1.674.10892.1.1000.30.1

Defines the Processor Port Table entry.

ProcessorPortTableEntry

Not accessible processorPortchassisIndex

, processorPortIndex

Table 680. Processor Port Chassis Index

Name processorPortchassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.30.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 681. Processor Port Index

Name

Object ID

Description

Syntax

Access processorPortIndex

1.3.6.1.4.1.674.10892.1.1000.30.1.2

Defines the index of the processor ports in this chassis.

DellObjectRange

Read-only

Table 682. Processor Port State Capabilities

Name

Object ID

Description

Syntax processorPortStateCapabilities

1.3.6.1.4.1.674.10892.1.1000.30.1.3

Defines the capabilities of the processor port.

DellStateCapabilities

154 Server Administrator Group

Table 682. Processor Port State Capabilities (continued)

Access Read-only

Table 683. Processor Port State Settings

Name

Object ID

Description

Syntax

Access processorPortStateSettings

1.3.6.1.4.1.674.10892.1.1000.30.1.4

Defines the state and settings of the processor port.

DellStateSettings

Read-only

Table 684. Processor Port Status

Name

Object ID

Description

Syntax

Access processorPortStatus

1.3.6.1.4.1.674.10892.1.1000.30.1.5

Defines the status of the processor port.

DellStatus

Read-only

Table 685. Processor Port Security State

Name processorPortSecurityState

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.30.1.6

Defines the security settings of the processor port.

DellPortSecurityState

Read-only

Table 686. Processor Port Connector Type

Name

Object ID

Description

Syntax

Access processorPortConnectorType

1.3.6.1.4.1.674.10892.1.1000.30.1.7

Defines the connector type of the processor port.

DellProcessorPortConnectorType (See Processor Port Connector Types

)

Read-only

Table 687. Processor Port Name

Name

Object ID

Description

Syntax

Access processorPortName

1.3.6.1.4.1.674.10892.1.1000.30.1.8

Defines name of the processor port.

DellString

Read-only

Table 688. Processor Port BIOS Connector Type

Name

Object ID

Description

Syntax processorPortBIOSConnectorType

1.3.6.1.4.1.674.10892.1.1000.30.1.9

Defines the BIOS connector type of the processor port.

DellGenericPortConnectorType

Server Administrator Group 155

Table 688. Processor Port BIOS Connector Type (continued)

Access Read-only

Memory Device Port Table

Table 689. Memory Device Port Table

Name memoryDevicePortTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.40

Defines the Memory Device Port Table.

IntegerMemoryDevicePortTableEntry

Not accessible

Table 690. Memory Device Port Table Entry

Name

Object ID

Description

Syntax

Access

Index memoryDevicePortTableEntry

1.3.6.1.4.1.674.10892.1.1000.40.1

Defines the Memory Device Port Table entry.

MemoryDevicePortTableEntry

Not accessible memoryDevicePortchassisIndex

, memoryDevicePortIndex

Table 691. Memory Device Port Chassis Index

Name memoryDevicePortchassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.40.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 692. Memory Device Port Index

Name

Object ID

Description

Syntax

Access memoryDevicePortIndex

1.3.6.1.4.1.674.10892.1.1000.40.1.2

Defines the index of the memory device port in this chassis.

DellObjectRange

Read-only

Table 693. Memory Device Port State Capabilities

Name

Object ID

Description

Syntax memoryDevicePortStateCapabilities

1.3.6.1.4.1.674.10892.1.1000.40.1.3

Defines the capabilities of the memory device port.

DellStateCapabilities

156 Server Administrator Group

Table 693. Memory Device Port State Capabilities (continued)

Access Read-only

Table 694. Memory Device Port State Settings

Name

Object ID

Description

Syntax

Access memoryDevicePortStateSettings

1.3.6.1.4.1.674.10892.1.1000.40.1.4

Defines the state and settings of the memory device port.

DellStateSettings

Read-only

Table 695. Memory Device Port Status

Name

Object ID

Description

Syntax

Access memoryDevicePortStatus

1.3.6.1.4.1.674.10892.1.1000.40.1.5

Defines the status of the memory device port.

DellStatus

Read-only

Table 696. Memory Device Port Security State

Name memoryDevicePortSecurityState

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.40.1.6

Defines the security settings of the memory device port.

DellPortSecurityState

Read-only

Table 697. Memory Device Port Connector Type

Name

Object ID

Description

Syntax

Access memoryDevicePortConnectorType

1.3.6.1.4.1.674.10892.1.1000.40.1.7

Defines the connector type of the memory device port.

DellMemoryDevicePortConnectorType (See

Memory Device Port Connector Types

)

Read-only

Table 698. Memory Device Port Name

Name

Object ID

Description

Syntax

Access memoryDevicePortName

1.3.6.1.4.1.674.10892.1.1000.40.1.8

Defines the name of the memory device port.

DellString

Read-only

Table 699. Memory Device Port BIOS Connector Type

Name

Object ID

Description

Syntax memoryDevicePortBIOSConnectorType

1.3.6.1.4.1.674.10892.1.1000.40.1.9

Defines the BIOS connector type of the memory device port.

DellGenericPortConnectorType

Server Administrator Group 157

Table 699. Memory Device Port BIOS Connector Type (continued)

Access Read-only

Table 700. Memory Device Port Physical Memory Array Index Reference

Name

Object ID

Description

Syntax

Access memoryDevicePortPhysicalMemoryArrayIndexReference

1.3.6.1.4.1.674.10892.1.1000.40.1.10

Defines the index to the associated physical memory array.

DellUnsigned32BitRange

Read-only

Table 701. Memory Device Port Physical Memory Card Index Reference

Name

Object ID

Description

Syntax

Access memoryDevicePortPhysicalMemoryCardIndexReference

1.3.6.1.4.1.674.10892.1.1000.40.1.11

Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any).

DellUnsigned32BitRange

Read-only

Monitor Port Table

Table 702. Monitor Port Table

Name

Object ID

Description

Syntax

Access monitorPortTable

1.3.6.1.4.1.674.10892.1.1000.50

Defines the Monitor Port Table.

IntegerMonitorPortTableEntry

Not accessible

Table 703. Monitor Port Table Entry

Name

Object ID

Description

Syntax

Access

Index monitorPortTableEntry

1.3.6.1.4.1.674.10892.1.1000.50.1

Defines the Monitor Port Table entry.

MonitorPortTableEntry

Not accessible monitorPortchassisIndex

, monitorPortIndex

Table 704. Monitor Port Chassis Index

Name

Object ID

Description monitorPortchassisIndex

1.3.6.1.4.1.674.10892.1.1000.50.1.1

Defines the index (one-based) of this chassis

158 Server Administrator Group

Table 704. Monitor Port Chassis Index (continued)

Syntax

Access

DellObjectRange

Read-only

Table 705. Monitor Port Index

Name

Object ID

Description

Syntax

Access monitorPortIndex

1.3.6.1.4.1.674.10892.1.1000.50.1.2

Defines the index of the monitor ports in this chassis.

DellObjectRange

Read-only

Table 706. Monitor Port State Capabilities

Name

Object ID

Description

Syntax

Access monitorPortStateCapabilities

1.3.6.1.4.1.674.10892.1.1000.50.1.3

Defines the capabilities of the monitor port.

DellStateCapabilities

Read-only

Table 707. Monitor Port State Settings

Name

Object ID

Description

Syntax

Access monitorPortStateSettings

1.3.6.1.4.1.674.10892.1.1000.50.1.4

Defines the state of the monitor port.

DellStateSettings

Read-only

Table 708. Monitor Port Status

Name

Object ID

Description

Syntax

Access monitorPortStatus

1.3.6.1.4.1.674.10892.1.1000.50.1.5

Defines the status of the monitor port.

DellStatus

Read-only

Table 709. Monitor Port Security State

Name monitorPortSecurityState

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.50.1.6

Defines the security settings of the monitor port.

DellPortSecurityState

Read-only

Table 710. Monitor Port Connector Type

Name

Object ID

Description monitorPortConnectorType

1.3.6.1.4.1.674.10892.1.1000.50.1.7

Defines the connector type of the monitor port.

Server Administrator Group 159

Table 710. Monitor Port Connector Type (continued)

Syntax

Access

DellMonitorPortConnectorTypes (See

Monitor Port Connector Types

)

Read-only

Table 711. Monitor Port Name

Name

Object ID

Description

Syntax

Access monitorPortName

1.3.6.1.4.1.674.10892.1.1000.50.1.8

Defines the name of the monitor port.

DellString

Read-only

Table 712. Monitor Port BIOS Connector Type

Name

Object ID

Description

Syntax

Access monitorPortBIOSConnectorType

1.3.6.1.4.1.674.10892.1.1000.50.1.9

Defines the name of the BIOS connector type of the monitor port.

DellGenericPortConnectorType

Read-only

Small Computer System Interface Port Table

Table 713. Small Computer System Interface Port Table

Name

Object ID

Description

Syntax

Access sCSIPortTable

1.3.6.1.4.1.674.10892.1.1000.60

Defines the SCSI Port Table.

IntegerSCSIPortTableEntry

Not accessible

Table 714. SCSI Port Table Entry

Name

Object ID

Description

Syntax

Access

Index sCSIPortTableEntry

1.3.6.1.4.1.674.10892.1.1000.60.1

Defines the SCSI Port Table entry.

SCSIPortTableEntry

Not accessible sCSIPortchassisIndex

, sCSIPortIndex

Table 715. SCSI Port Chassis Index

Name

Object ID

Description sCSIPortchassisIndex

1.3.6.1.4.1.674.10892.1.1000.60.1.1

Defines the index (one-based) of this chassis

160 Server Administrator Group

Table 715. SCSI Port Chassis Index (continued)

Syntax

Access

DellObjectRange

Read-only

Table 716. SCSI Port Index

Name

Object ID

Description

Syntax

Access sCSIPortIndex

1.3.6.1.4.1.674.10892.1.1000.60.1.2

Defines the index of the SCSI ports in this chassis.

DellObjectRange

Read-only

Table 717. SCSI Port State Capabilities

Name

Object ID

Description

Syntax

Access sCSIPortStateCapabilities

1.3.6.1.4.1.674.10892.1.1000.60.1.3

Defines the capabilities of the SCSI port.

DellStateCapabilities

Read-only

Table 718. SCSI Port State Settings

Name

Object ID

Description

Syntax

Access

DellStateSettings

1.3.6.1.4.1.674.10892.1.1000.60.1.4

Defines the state and settings of the SCSI port.

DellStatus

Read-only

Table 719. SCSI Port Status

Name

Object ID

Description

Syntax

Access sCSIPortStatus

1.3.6.1.4.1.674.10892.1.1000.60.1.5

Defines the status of the SCSI port.

DellStatus

Read-only

Table 720. SCSI Port Security State

Name sCSIPortSecurityState

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.60.1.6

Defines the security settings of the SCSI port.

DellPortSecurityState

Read-only

Table 721. SCSI Port Connector Type

Name

Object ID

Description sCSIPortConnectorType

1.3.6.1.4.1.674.10892.1.1000.60.1.7

Defines the connector type of the SCSI port.

Server Administrator Group 161

Table 721. SCSI Port Connector Type (continued)

Syntax

Access

DellSCSIPortConnectorType (See

SCSI Port Connector Types )

Read-only

Table 722. SCSI Port Name

Name

Object ID

Description

Syntax

Access sCSIPortName

1.3.6.1.4.1.674.10892.1.1000.60.1.8

Defines the name of the SCSI port.

DellString

Read-only

Table 723. SCSI Port BIOS Connector Type

Name

Object ID

Description

Syntax

Access sCSIPortBIOSConnectorType

1.3.6.1.4.1.674.10892.1.1000.60.1.9

Defines the BIOS connector type of the SCSI port.

DellGenericPortConnectorType

Read-only

Parallel Port Table

Table 724. Parallel Port Table

Name

Object ID

Description

Syntax

Access parallelPortTable

1.3.6.1.4.1.674.10892.1.1000.70

Defines the Parallel Port Table.

IntegerParallelPortTableEntry

Not accessible

Table 725. Parallel Port Table Entry

Name

Object ID

Description

Syntax

Access

Index parallelPortTableEntry

1.3.6.1.4.1.674.10892.1.1000.70.1

Defines the Parallel Port Table entry.

ParallelPortTableEntry

Not accessible parallelPortchassisIndex

, parallelPortIndex

Table 726. Parallel Port Chassis Index

Name

Object ID

Description parallelPortchassisIndex

1.3.6.1.4.1.674.10892.1.1000.70.1.1

Defines the index (one-based) of this chassis.

162 Server Administrator Group

Table 726. Parallel Port Chassis Index (continued)

Syntax

Access

DellObjectRange

Read-only

Table 727. Parallel Port Index

Name

Object ID

Description

Syntax

Access parallelPortIndex

1.3.6.1.4.1.674.10892.1.1000.70.1.2

Defines the index of the parallel ports in this chassis.

DellObjectRange

Read-only

Table 728. Parallel Port State Capabilities

Name

Object ID

Description

Syntax

Access parallelPortStateCapabilities

1.3.6.1.4.1.674.10892.1.1000.70.1.3

Defines the capabilities of the parallel port.

DellStateSettings

Read-only

Table 729. Parallel Port State Settings

Name

Object ID

Description

Syntax

Access parallelPortStateSettings

1.3.6.1.4.1.674.10892.1.1000.70.1.4

Defines the state and settings of the parallel port.

DellStateSettings

Read-only

Table 730. Parallel Port Status

Name

Object ID

Description

Syntax

Access parallelPortStatus

1.3.6.1.4.1.674.10892.1.1000.70.1.5

Defines the status of the parallel port.

DellStatus

Read-only

Table 731. Parallel Port Security State

Name DellPortSecurityState

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.70.1.6

Defines the security state of the parallel port.

DellStatus

Read-only

Table 732. Parallel Port Connector Type

Name

Object ID

Description parallelPortConnectorType

1.3.6.1.4.1.674.10892.1.1000.70.1.7

Defines the connector type of the parallel port.

Server Administrator Group 163

Table 732. Parallel Port Connector Type (continued)

Syntax

Access

DellParallelPortConnectorType

Read-only

Table 733. Parallel Port Name

Name

Object ID

Description

Syntax

Access parallelPortName

1.3.6.1.4.1.674.10892.1.1000.70.1.8

Defines the name of the parallel port.

DellString

Read-only

Table 734. Parallel Port Connector Pin Out

Name

Object ID

Description

Syntax

Access parallelPortConnectorPinOut

1.3.6.1.4.1.674.10892.1.1000.70.1.9

Defines the pinout of the parallel port.

DellParallelPortConnectorPinout

Read-only

Table 735. Parallel Port Capabilities Unique

Name

Object ID

Description

Syntax

Access parallelPortCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1000.70.1.10

Defines the capabilities of the parallel port.

DellParallelPortConnectorPinout

Read-only

Table 736. Parallel Port Base I/O Address

Name

Object ID

Description

Syntax

Access parallelPortBaseIOAddress

1.3.6.1.4.1.674.10892.1.1000.70.1.11

Defines the Base Input/Output (I/O) address of the parallel port.

DellUnsigned64BitRange

Read-only

Table 737. Parallel Port IRQ Level

Name parallelPortIRQLevel

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1000.70.1.12

Defines the Interrupt Request Level (IRQ) of the parallel port.

DellUnsigned8BitRange

Read-only

Table 738. Parallel Port DMA Support

Name

Object ID

Description parallelPortDMASupport

1.3.6.1.4.1.674.10892.1.1000.70.1.13

Defines if direct memory access (DMA) is supported by the parallel port.

164 Server Administrator Group

Table 738. Parallel Port DMA Support (continued)

Syntax

Access

DellBoolean

Read-only

Serial Port Table

Table 739. Serial Port

Name

Object ID

Description

Syntax

Access serialPortTable

1.3.6.1.4.1.674.10892.1.1000.80

Defines the Serial Port Table.

IntegerSerialPortTableEntry

Not accessible

Table 740. Serial Port Table Entry

Name

Object ID

Description

Syntax

Access

Index serialPortTableEntry

1.3.6.1.4.1.674.10892.1.1000.80.1

Defines the Serial Port Table entry.

SerialPortTableEntry

Not accessible serialPortchassisIndex

, serialPortIndex

Table 741. Serial Port Chassis Index

Name

Object ID

Description

Syntax

Access serialPortchassisIndex

1.3.6.1.4.1.674.10892.1.1000.80.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 742. Serial Port Index

Name

Object ID

Description

Syntax

Access serialPortIndex

1.3.6.1.4.1.674.10892.1.1000.80.1.2

Defines the index of the serial ports in this chassis.

DellObjectRange

Read-only

Table 743. Serial Port State Capabilities

Name

Object ID

Description serialPortStateCapabilities

1.3.6.1.4.1.674.10892.1.1000.80.1.3

Defines the capabilities of the serial port.

Server Administrator Group 165

Table 743. Serial Port State Capabilities (continued)

Syntax

Access

DellStateCapabilities

Read-only

Table 744. Serial Port State Settings

Name

Object ID

Description

Syntax

Access serialPortStateSettings

1.3.6.1.4.1.674.10892.1.1000.80.1.4

Defines the state and settings of the serial port.

DellStateSettings

Read-only

Table 745. Serial Port Status

Name

Object ID

Description

Syntax

Access serialPortStatus

1.3.6.1.4.1.674.10892.1.1000.80.1.5

Defines the status of the serial port.

DellStatus

Read-only

Table 746. Serial Port Security State

Name

Object ID

Description

Syntax

Access serialPortSecurityState

1.3.6.1.4.1.674.10892.1.1000.80.1.6

Defines the security settings of the serial port.

DellPortSecurityState

Read-only

Table 747. Serial Port Connector Type

Name

Object ID

Description

Syntax

Access serialPortConnectorType

1.3.6.1.4.1.674.10892.1.1000.80.1.7

Defines connector type of the serial port.

DellSerialPortConnectorType

Read-only

Table 748. Serial Port Name

Name

Object ID

Description

Syntax

Access serialPortName

1.3.6.1.4.1.674.10892.1.1000.80.1.8

Defines the name of the serial port.

DellString

Read-only

Table 749. Serial Port Maximum Speed

Name

Object ID

Description serialPortMaximumSpeed

1.3.6.1.4.1.674.10892.1.1000.80.1.9

Defines the maximum speed the serial interface can support in bits per second (bps).

166 Server Administrator Group

Table 749. Serial Port Maximum Speed (continued)

Syntax

Access

DellUnsigned32BitRange

Read-only

Table 750. Serial Port Capabilities Unique

Name

Object ID

Description

Syntax

Access serialPortCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1000.80.1.10

Defines additional capabilities of the serial port.

DellSerialPortCapabilitiesUnique

Read-only

Table 751. Serial Port Base I/O Address

Name

Object ID

Description

Syntax

Access serialPortBaseIOAddress

1.3.6.1.4.1.674.10892.1.1000.80.1.11

Defines the base I/O address of the serial port.

DellUnsigned64BitRange

Read-only

Table 752. Serial Port IRQ Level

Name

Object ID

Description

Syntax

Access serialPortIRQLevel

1.3.6.1.4.1.674.10892.1.1000.80.1.12

Defines the IRQ of the serial port.

DellUnsigned8BitRange

Read-only

Universal Serial Bus Port Table

Table 753. Universal Serial Bus Port

Name

Object ID

Description

Syntax

Access uSBPortTable

1.3.6.1.4.1.674.10892.1.1000.90

Defines the USB Port Table.

IntegerUSBPortTableEntry

Not accessible

Table 754. USB Port Table Entry

Name

Object ID

Description

Syntax

Access

Index uSBPortTableEntry

1.3.6.1.4.1.674.10892.1.1000.90.1

Defines the USB Port Table entry.

USBPortTableEntry

Not accessible uSBPortchassisIndex , uSBPortIndex

Server Administrator Group 167

Table 755. USB Port Chassis Index

Name

Object ID

Description

Syntax

Access uSBPortchassisIndex

1.3.6.1.4.1.674.10892.1.1000.90.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 756. USB Port Index

Name

Object ID

Description

Syntax

Access uSBPortIndex

1.3.6.1.4.1.674.10892.1.1000.90.1.2

Defines the index of the USB ports in this chassis

DellObjectRange

Read-only

Table 757. USB Port State Capabilities

Name

Object ID

Description

Syntax

Access uSBPortStateCapabilities

1.3.6.1.4.1.674.10892.1.1000.90.1.3

Defines the capabilities of the USB port.

DellStateCapabilities

Read-only

Table 758. USB Port State Settings

Name

Object ID

Description

Syntax

Access uSBPortStateSettings

1.3.6.1.4.1.674.10892.1.1000.90.1.4

Defines the state and settings of the USB port.

DellStateSettings

Read-only

Table 759. USB Port Status

Name

Object ID

Description

Syntax

Access uSBPortStatus

1.3.6.1.4.1.674.10892.1.1000.90.1.5

Defines the state of the USB port.

DellStatus

Read-only

Table 760. USB Port Security State

Name

Object ID

Description

Syntax

Access uSBPortSecurityState

1.3.6.1.4.1.674.10892.1.1000.90.1.6

Defines the security settings of the USB port.

DellPortSecurityState

Read-only

168 Server Administrator Group

Table 761. USB Port Connector Type

Name

Object ID

Description

Syntax

Access uSBPortConnectorType

1.3.6.1.4.1.674.10892.1.1000.90.1.7

Defines the connector type of the USB port.

DellUSBPortConnectorType

Read-only

Table 762. USB Port Name

Name

Object ID

Description

Syntax

Access uSBPortName

1.3.6.1.4.1.674.10892.1.1000.90.1.8

Defines the name of the USB port.

DellString

Read-only

Port Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 763. Pointing Port Connector Type

Variable Name: DellPointingPortConnectorType

Data Type : Integer

Possible Data Values connectorPortTypeIsOther(1)

Meaning of Data Value

The pointing port connector type is not one of the following: connectorPortTypeIsUnknown(2) The pointing port connector type is unknown.

connectorPortTypeIsSerial(3) The pointing port connector type is serial.

connectorPortTypeIsPS2(4) The pointing port connector type is a

Personal System/2 (PS/2).

connectorPortTypeIsInfrared(5

) connectorPortTypeIsHPHIL(6)

The pointing port connector type is infrared.

The pointing port connector type is HP-

HIL.

connectorPortTypeIsBusMouse(7

)

The pointing port connector type is a bus mouse.

connectorPortTypeIsADB(8) connectorPortTypeIsDB9(9) connectorPortTypeIsMicroDIN(1

0) connectorPortTypeIsAccessBusU

SB (11) connectorPortTypeIsPC98(12)

The pointing port connector type is ADB.

The pointing port connector type is ninepin DB-9.

The pointing port connector type is micro Deutsche Industrie Norm (DIN).

The pointing port connector type is

Access Bus USB.

The port connector type is a PC-98.

Server Administrator Group 169

Table 764. Keyboard Port Connector Types

Variable Name : DellKeyboardPortConnectorType

Data Type: Integer

Possible Data Values connectorPortTypeIsOther(1) connectorPortTypeIsUnknown(2) connectorPortTypeIsMiniDIN(3) connectorPortTypeIsMicroDIN(4) connectorPortTypeIsPS2(5) connectorPortTypeIsInfrared(6) connectorPortTypeIsHPHIL(7) connectorPortTypeIsDB9(8) connectorPortTypeIsAccessBusUSB(9) connectorPortTypeIsPC98(10)

Meaning of Data Value

The keyboard port connector type is not one of the following:

The keyboard port connector type is unknown.

The keyboard port connector type is a mini DIN.

The keyboard port connector type is a MicroDIN.

The keyboard port connector type is PS/2.

The keyboard port connector type is infrared.

The keyboard port connector type is HP-HIL.

The keyboard port connector type is DB-9.

The keyboard port connector type is bus USB.

The keyboard port connector type is PC-98.

Table 765. Processor Port Connector Types

Variable Name : DellProcessorPortConnectorType

Data Type: Integer

Possible Data Values connectorPortTypeIsOther(1) connectorPortTypeIsUnknown(2) connectorPortTypeIsDaughterdBoard(3) connectorPortTypeIsZIFSocket(4) connectorPortTypeIsAPiggyBackBoard(5) connectorPortTypeIsNone(6) connectorPortTypeIsLIFSocket(7) connectorPortTypeIsSlot1(8) connectorPortTypeIsSlot2(9) connectorPortTypeIs370PinSocket(10)

Meaning of Data Value

The processor port connector type is not one of the following:

The processor port connector type is unknown.

The processor port connector type is a daughter board.

The processor port connector type is a zero insertion force

(ZIF) socket.

The processor port connector type is a replacement piggyback board.

There is no processor port connector; processor is soldered in place.

The processor port connector type is a low insertion force

(LIF) socket.

The processor port connector type is a slot one.

The processor port connector type is a slot two.

The processor port connector type is a 370 pin socket.

Table 766. Memory Device Port Connector Types

Variable Name : DellMemoryDevicePortConnectorType

Data Type: Integer

Possible Data Values connectorPortTypeIsOther(1) connectorPortTypeIsUnknown(2)

Meaning of Data Value

The memory device port connector type is not one of the following:

The memory device port connector type is unknown.

170 Server Administrator Group

Table 766. Memory Device Port Connector Types (continued) connectorPortTypeIsSIMM(3) connectorPortTypeIsSIP(4) connectorPortTypeIsAChip(5) connectorPortTypeIsDIP(6) connectorPortTypeIsZIP(7) connectorPortTypeIsAProprietaryCard(8) connectorPortTypeIsDIMM(9) connectorPortTypeIsTSOP(10) connectorPortTypeIsARowOfChips(11) connectorPortTypeIsRIMM(12) connectorPortTypeIsSODIMM(13) connectorPortTypeIsSRIMM(14)

The memory device port connector type is a single in-line memory module (SIMM).

The memory device port connector type is a SIP.

The memory device port connector type is a chip.

The memory device port connector type is a dual in-line package (DIP).

The memory device port connector type is a ZIP.

The memory device port connector type is a proprietary card.

The memory device port connector type is a dual in-line memory module (DIMM).

The memory device port connector type is a TSOP.

The memory device port connector type is a row of chips.

The memory device port connector type is a Rambus Inline

Memory Module (RIMM).

The memory device port connector type is a small outline, dual in-line memory module (SODIMM).

The memory device port connector type is a SRIMM.

Table 767. Monitor Port Connector Types

Variable Name : DellMonitorPortConnectorType

Data Type: Integer

Possible Data Values connectorPortTypeIsOther(1) connectorPortTypeIsUnknown(2) connectorPortTypeIsDB15PinMale(3) connectorPortTypeIsDB15PinFemale(4)

Meaning of Data Value

The monitor port connector type is not one of the following:

The monitor port connector type is unknown.

The monitor port connector type is a male DB-15.

The monitor port connector type is a female DB-15.

Table 768. SCSI Port Connector Types

Variable Name : DellSCSIPortConnectorType

Data Type: Integer

Possible Data Values connectorPortTypeIsOther(1) connectorPortTypeIsUnknown(2) connectorPortTypeIsDIN25pin(3) connectorPortTypeIsDIN50pin(4) connectorPortTypeIsDIN68pin(5)

Meaning of Data Value

The SCSI port connector type is not one of the following:

The SCSI port connector type is unknown.

The SCSI port connector type is a DIN 25-pin.

The SCSI port connector type is a DIN 50-pin.

The SCSI port connector type is a DIN 68-pin.

Device Group

The Device Group provides information about different types of pointing, keyboard, processor, cache, memory, and peripheral component interconnect (PCI) devices. Variables in this group cover information about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device.

Server Administrator Group 171

Device Tables

The following management information base (MIB) tables define objects in the Device Group:

Pointing Device Table

Keyboard Device Table

Processor Device Table

Processor Device Status Table

Cache Device Table

Memory Device Table

Memory Device Mapped Address Table

Generic Device Table

PCI Device Table

PCI Device Configuration Space Table

Network Device Table

Managed System Services Device Table

SD Card Unit Table

SD Card Device Table

Pointing Device Table

Table 769. Pointing Device Table

Name

Object ID

Description

Syntax

Access pointingDeviceTable

1.3.6.1.4.1.674.10892.1.1100.10

Defines the Pointing Device Table. This group of objects references the Pointing Port

Index (

Pointing Port Index

).

SEQUENCE OF PointingDeviceTableEntry

Not accessible

Table 770. Pointing Device Table Entry

Name

Object ID

Description

Syntax

Access

Index pointingDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.10.1

Defines the Pointing Device Table entry.

PointingDeviceTableEntry

Not accessible pointingDevicechassisIndex

, pointingDeviceIndex

Table 771. Pointing Device Chassis Index

Name

Object ID

Description

Syntax

Access pointingDevicechassisIndex

1.3.6.1.4.1.674.10892.1.1100.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

172 Server Administrator Group

Table 772. Pointing Device Index

Name

Object ID

Description

Syntax

Access pointingDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.10.1.2

Defines the index of the pointing device in this chassis.

DellObjectRange

Read-only

Table 773. Pointing Device State Capabilities

Name

Object ID

Description

Syntax

Access pointingDeviceStateCapabilities

1.3.6.1.4.1.674.10892.1.1100.10.1.3

Defines the capabilities of the pointing device.

DellStateCapabilities

Read-only

Table 774. Pointing Device State Settings

Name

Object ID

Description

Syntax

Access pointingDeviceStateSettings

1.3.6.1.4.1.674.10892.1.1100.10.1.4

Defines the state of the pointing device.

DellStateSettings

Read-only

Table 775. Pointing Device Status

Name

Object ID

Description

Syntax

Access pointingDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.10.1.5

Defines the status of the pointing device.

DellStatus

Read-only

Table 776. Pointing Port Index Reference

Name

Object ID

Description

Syntax

Access pointingPortIndexReference

1.3.6.1.4.1.674.10892.1.1100.10.1.6

Defines the index to the pointing port in this chassis.

DellObjectRange

Read-only

Table 777. Pointing Device Type

Name

Object ID

Description

Syntax

Access pointingDeviceType

1.3.6.1.4.1.674.10892.1.1100.10.1.7

Defines the type of the pointing device.

DellPointingDeviceType (See Pointing Device Type

)

Read-only

Server Administrator Group 173

Table 778. Pointing Device Number of Buttons

Name

Object ID

Description

Syntax

Access pointingDeviceNumberofButtons

1.3.6.1.4.1.674.10892.1.1100.10.1.8

Defines the number of buttons on the pointing device.

DellUnsigned8BitRange

Read-only

Keyboard Device Table

Table 779. Keyboard Device Table

Name

Object ID

Description

Syntax

Access keyboardDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.20

Defines the Keyboard Device Table. This table references the Keyboard Port Index

(

Keyboard Port Index

).

SEQUENCE OF KeyboardDeviceTableEntry

Not accessible

Table 780. Keyboard Device Table Entry

Name

Object ID

Description

Syntax

Access

Index keyboardDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.20.1

Defines the Keyboard Device Table entry.

KeyboardDeviceTableEntry

Not accessible keyboardDevicechassisIndex

, keyboardDeviceIndex

Table 781. Keyboard Device Chassis Index

Name keyboardDevicechassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 782. Keyboard Device Index

Name

Object ID

Description

Syntax

Access keyboardDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.20.1.2

Defines the index of the keyboard device for this chassis.

DellObjectRange

Read-only

174 Server Administrator Group

Table 783. Keyboard Device State Capabilities

Name

Object ID

Description

Syntax

Access keyboardDeviceStateCapabilities

1.3.6.1.4.1.674.10892.1.1100.20.1.3

Defines the capabilities of the keyboard device.

DellStateCapabilities

Read-only

Table 784. Keyboard Device State Settings

Name

Object ID

Description

Syntax

Access keyboardDeviceStateSettings

1.3.6.1.4.1.674.10892.1.1100.20.1.4

Defines the state of the keyboard device.

DellStatesSettings

Read-only

Table 785. Keyboard Device Status

Name

Object ID

Description

Syntax

Access keyboardDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.20.1.5

Defines the status of the keyboard device.

DellStatus

Read-only

Table 786. Keyboard Port Index Reference

Name

Object ID

Description

Syntax

Access keyboardPortIndexReference

1.3.6.1.4.1.674.10892.1.1100.20.1.6

Defines the index to the associated the keyboard port in this chassis.

DellStatus

Read-only

Table 787. Keyboard Device Type Name

Name

Object ID

Description

Syntax

Access keyboardDeviceTypeName

1.3.6.1.4.1.674.10892.1.1100.20.1.7

Defines the name of the keyboard type.

DellString

Read-only

Table 788. Keyboard Device Layout Name

Name

Object ID

Description

Syntax

Access keyboardDeviceLayoutName

1.3.6.1.4.1.674.10892.1.1100.20.1.8

Defines the name of the keyboard layout.

DellString

Read-only

Server Administrator Group 175

Processor Device Table

Table 789. Processor Device Table

Name

Object ID

Description

Syntax

Access processorDeviceTable

1.3.6.1.4.1.674.10892.1.1100.30

Defines the Processor Device Table.

SEQUENCE OF ProcessorDeviceTableEntry

Not accessible

Table 790. Processor Device Table Entry

Name

Object ID

Description

Syntax

Access

Index processorDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.30.1

Defines the Processor Device Table entry.

ProcessorDeviceTableEntry

Not accessible processorDevicechassisIndex

, processorDeviceIndex

Table 791. Processor Device Chassis Index

Name

Object ID

Description

Syntax

Access processorDevicechassisIndex

1.3.6.1.4.1.674.10892.1.1100.30.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 792. Processor Device Index

Name

Object ID

Description

Syntax

Access processorDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.30.1.2

Defines the index of the processor device in this chassis.

DellObjectRange

Read-only

Table 793. Processor Device State Capabilities

Name

Object ID

Description

Syntax

Access processorDeviceStateCapabilities

1.3.6.1.4.1.674.10892.1.1100.30.1.3

Defines the capabilities of the processor device.

DellStateCapabilities

Read-only

176 Server Administrator Group

Table 794. Processor Device State Settings

Name

Object ID

Description

Syntax

Access processorDeviceStateSettings

1.3.6.1.4.1.674.10892.1.1100.30.1.4

Defines the state of the processor device.

DellStateSettings

Read-only

Table 795. Processor Device Status

Name

Object ID

Description

Syntax

Access processorDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.30.1.5

Defines the status of the processor device.

DellStatus

Read-only

Table 796. Processor Port Index Reference

Name

Object ID

Description

Syntax

Access processorPortIndexReference

1.3.6.1.4.1.674.10892.1.1100.30.1.6

Defines the index to the associated processor port in this chassis.

DellObjectRange

Read-only

Table 797. Processor Device Type

Name

Object ID

Description

Syntax

Access processorDeviceType

1.3.6.1.4.1.674.10892.1.1100.30.1.7

Defines the type of processor device.

DellProcessorDeviceType (See

Processor Device Type

)

Read-only

Table 798. Processor Device Manufacturer Name

Name

Object ID

Description

Syntax

Access processorDeviceManufacturerName

1.3.6.1.4.1.674.10892.1.1100.30.1.8

Defines the name of manufacturer of the processor device.

DellString

Read-only

Table 799. Processor Device Status State

Name

Object ID

Description

Syntax

Access processorDeviceStatusState

1.3.6.1.4.1.674.10892.1.1100.30.1.9

Defines the status state of the processor device.

DellProcessorDeviceStatusState (See

Processor Device Status State

)

Read-only

Server Administrator Group 177

Table 800. Processor Device Family

Name

Object ID

Description

Syntax

Access processorDeviceFamily

1.3.6.1.4.1.674.10892.1.1100.30.1.10

Defines the family of the processor device.

DellProcessorDeviceFamily (See

Processor Device Family )

Read-only

Table 801. Processor Device Maximum Speed

Name

Object ID

Description

Syntax

Access processorDeviceMaximumSpeed

1.3.6.1.4.1.674.10892.1.1100.30.1.11

Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown.

DellUnsigned32BitRange

Read-only

Table 802. Processor Device Current Speed

Name

Object ID

Description

Syntax

Access processorDeviceCurrentSpeed

1.3.6.1.4.1.674.10892.1.1100.30.1.12

Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown.

DellUnsigned32BitRange

Read-only

Table 803. Processor Device External Clock Speed

Name

Object ID

Description

Syntax

Access processorDeviceExternalClockSpeed

1.3.6.1.4.1.674.10892.1.1100.30.1.13

Defines the speed of the external clock (the front-side bus speed) for the processor device in MHz. A zero (0) indicates that the speed is unknown.

DellUnsigned32BitRange

Read-only

Table 804. Processor Device Voltage

Name

Object ID

Description

Syntax

Access processorDeviceVoltage

1.3.6.1.4.1.674.10892.1.1100.30.1.14

Defines the voltage powering the processor device in millivolts. A zero (0) indicates the speed is unknown.

DellSigned32BitRange

Read-only

Table 805. Processor Device Upgrade Information

Name

Object ID

Description

Syntax processorDeviceUpgradeInformation

1.3.6.1.4.1.674.10892.1.1100.30.1.15

Defines the processor upgrade information for the processor device.

DellProcessorUpgradeInformation (See

Processor Upgrade Information

)

178 Server Administrator Group

Table 805. Processor Device Upgrade Information (continued)

Access Read-only

Table 806. Processor Device Version Name

Name

Object ID

Description

Syntax

Access processorDeviceVersionName

1.3.6.1.4.1.674.10892.1.1100.30.1.16

Defines the version name of the processor device.

DellString

Read-only

Table 807. Processor Device Core Count

Name

Object ID

Description

Syntax

Access processorDeviceCoreCount

1.3.6.1.4.1.674.10892.1.1100.30.1.17

Defines the number of processor cores detected for the processor device.

DellUnsigned32BitRange

Read-only

Table 808. Processor Device Core Enabled Count

Name processorDeviceCoreEnabledCount

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.30.1.18

Defines the number of processor cores enabled for the processor device.

DellUnsigned32BitRange

Read-only

Table 809. Processor Device Thread Count

Name

Object ID

Description

Syntax

Access processorDeviceThreadCount

1.3.6.1.4.1.674.10892.1.1100.30.1.19

Defines the number of processor threads detected for the processor device.

DellUnsigned32BitRange

Read-only

Table 810. Processor Device Characteristics

Name

Object ID

Description processorDeviceCharacteristics

1.3.6.1.4.1.674.10892.1.1100.30.1.20

This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).

NOTE: Bits 2-15 need to be examined in the context of bit 1. If bit 1 is set, the processor characteristics are unknown and bits 2-15 cannot be used to determine if the functions associated with the bits are supported.

Bit Position

Bit 0

Bit 1

Bit 2

Meaning if Set

Reserved

Unknown

64-bit capable

Server Administrator Group 179

Table 810. Processor Device Characteristics (continued)

Bit Position

Bit 3-15

Meaning if Set

Reserved

Syntax

Access

DellUnsigned16BitRange

Read-only

Table 811. Processor Device Extended Capabilities

Name

Object ID

Description processorDeviceExtendedCapabilities

1.3.6.1.4.1.674.10892.1.1100.30.1.21

This attribute defines extended capabilities of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).

NOTE: This attribute should consider processorDeviceDeprecatedCapabilities for deprecated values.

Bit Position

Bit 0

Bit 1

Bit 2

Bit 3

Meaning if Set

Virtualization Technology (VT) supported

Demand-Based Switching (DBS) supported eXecute Disable (XD) supported

Hyper-Threading (HT) supported

Syntax

Access

DellUnsigned16BitRange

Read-only

Table 812. Processor Device Extended Settings

Name

Object ID

Description processorDeviceExtendedSettings

1.3.6.1.4.1.674.10892.1.1100.30.1.22

This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).

Bit Position

Bit 0

Bit 1

Bit 2

Bit 3

Meaning if Set

Virtualization Technology (VT) supported

Demand-Based Switching (DBS) supported eXecute Disable (XD) supported

Hyper-Threading (HT) supported

Bit 4 Turbo Mode (TM) supported

Syntax

Access

DellUnsigned16BitRange

Read-only

Table 813. Processor Device Brand Name

Name

Object ID

Description

Syntax

Access processorDeviceBrandName

1.3.6.1.4.1.674.10892.1.1100.30.1.23

Defines the brand of the processor device.

DellString

Read-only

180 Server Administrator Group

Table 814. Processor Device Model Name

Name

Object ID

Description

Syntax

Access processorDeviceModelName

1.3.6.1.4.1.674.10892.1.1100.30.1.24

Defines the model of the processor device.

DellString

Read-only

Table 815. Processor Device Stepping Name

Name

Object ID

Description

Syntax

Access processorDeviceSteppingName

1.3.6.1.4.1.674.10892.1.1100.30.1.25

Defines the stepping of the processor device.

DellString

Read-only

Table 816. Processor Device Deprecated Capabilities

Name

Object ID

Description processorDeviceDeprecatedCapabilities

1.3.6.1.4.1.674.10892.1.1100.30.1.26

This attribute defines deprecated capabilities of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).

NOTE: This attribute should be used to ignore deprecated Capabilities from processorDeviceExtendedCapabilities . The deprecated values should not be consumed or displayed as they might have default values.

Bit Position

Bit 0

Bit 1

Bit 2

Bit 3

Meaning if Set

Virtualization Technology (VT) is deprecated

Demand-Based Switching (DBS) is deprecated eXecute Disable (XD) is deprecated

Hyper-Threading (HT) is deprecated

Bit 4 Turbo Mode (TM) is deprecated

Syntax

Access

DellUnsigned16BitRange

Read-only

Processor Device Status Table

Table 817. Processor Device Status Table

Name

Object ID

Description

Syntax

Access processorDeviceStatusTable

1.3.6.1.4.1.674.10892.1.1100.32

Defines the Processor Device Status Table.

SEQUENCE OF ProcessorDeviceStatusTableEntry

Not accessible

Table 818. Processor Device Status Table Entry

Name processorDeviceStatusTableEntry

Server Administrator Group 181

Table 818. Processor Device Status Table Entry (continued)

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.1100.32.1

Defines the Processor Device Status Table Entry.

ProcessorDeviceStatusTableEntry

Not accessible processorDeviceStatusChassisIndex

, processorDeviceStatusIndex

Table 819. Processor Device Status Chassis Index

Name

Object ID

Description

Syntax

Access processorDeviceStatusChassisIndex

1.3.6.1.4.1.674.10892.1.1100.32.1.1

Defines the index (one-based) of the associated chassis.

DellObjectRange

Read-only

Table 820. Processor Device Status Index

Name

Object ID

Description

Syntax

Access processorDeviceStatusIndex

1.3.6.1.4.1.674.10892.1.1100.32.1.2

Defines the index (one-based) of the processor device status probe.

DellObjectRange

Read-only

Table 821. Processor Device Status State Capabilities

Name

Object ID

Description

Syntax

Access processorDeviceStatusStateCapabilities

1.3.6.1.4.1.674.10892.1.1100.32.1.3

Defines the state capabilities of the processor device status probe.

DellStateCapabilities

Read-only

Table 822. Processor Device Status State Settings

Name

Object ID

Description

Syntax

Access processorDeviceStatusStateSettings

1.3.6.1.4.1.674.10892.1.1100.32.1.4

Defines the state settings of the processor device status probe.

DellStateSettings

Read-only

Table 823. Processor Device Status

Name

Object ID processorDeviceStatusStatus

1.3.6.1.4.1.674.10892.1.1100.32.1.5

182 Server Administrator Group

Table 823. Processor Device Status (continued)

Description

Syntax

Access

Defines the status of the processor device status probe. This status is joined into the processorDeviceStatus attribute.

DellStatus

Read-only

Table 824. Processor Device Status Reading

Name

Object ID

Description

Syntax

Access processorDeviceStatusReading

1.3.6.1.4.1.674.10892.1.1100.32.1.6

Defines the reading of the processor device status probe.

DellProcessorDeviceStatusReading

Read-only

Table 825. Processor Device Status Location Name

Name processorDeviceStatusLocationName

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.32.1.7

Defines the location name of the processor device status probe.

DellString

Read-only

Table 826. Processor Device Status Port Index Reference

Name

Object ID

Description

Syntax

Access processorDeviceStatusPortIndexReference

1.3.6.1.4.1.674.10892.1.1100.32.1.8

Defines the index (one-based) of the associated processor port in the same chassis.

DellObjectRange

Read-only

Cache Device Table

Table 827. Cache Device Table

Name

Object ID

Description

Syntax

Access cacheDeviceTable

1.3.6.1.4.1.674.10892.1.1100.40

Defines the Cache Device Table.

SEQUENCE OF CacheDeviceTableEntry

Not accessible

Table 828. Cache Device Table Entry

Name

Object ID

Description

Syntax

Access cacheDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.40.1

Defines the Cache Device Table entry.

CacheDeviceTableEntry

Not accessible

Server Administrator Group 183

Table 828. Cache Device Table Entry (continued)

Index cacheDevicechassisIndex

, cacheDeviceIndex

Table 829. Cache Device Chassis Index

Name

Object ID

Description

Syntax

Access cacheDevicechassisIndex

1.3.6.1.4.1.674.10892.1.1100.40.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 830. Cache Device Index

Name

Object ID

Description

Syntax

Access cacheDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.40.1.2

Defines the index of the cache device in this chassis.

DellObjectRange

Read-only

Table 831. Cache Device State Capabilities

Name cacheDeviceStateCapabilities

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.40.1.3

Description Defines the capabilities of the cache device.

DellStateCapabilities

Read-only

Table 832. Cache Device State Settings

Name

Object ID

Description

Syntax

Access cacheDeviceStateSettings

1.3.6.1.4.1.674.10892.1.1100.40.1.4

Description Defines the state of the cache device.

DellStateSettings

Read-only

Table 833. Cache Device Status

Name

Object ID

Description

Syntax

Access cacheDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.40.1.5

Defines the status of the cache device.

DellStatus

Read-only

184 Server Administrator Group

Table 834. Cache Device Processor Device Index Reference

Name

Object ID

Description

Syntax

Access cacheDeviceprocessorDeviceIndexReference

1.3.6.1.4.1.674.10892.1.1100.40.1.6

Defines the index number of the processor device with which this cache device is associated.

DellObjectRange

Read-only

Table 835. Cache Device Type

Name

Object ID

Description

Syntax

Access cacheDeviceType

1.3.6.1.4.1.674.10892.1.1100.40.1.7

Defines the type of cache device.

DellCacheDeviceType (See

Cache Device Type

)

Read-only

Table 836. Cache Device Location

Name

Object ID

Description

Syntax

Access cacheDeviceLocation

1.3.6.1.4.1.674.10892.1.1100.40.1.8

Defines the location of the cache device.

DellCacheDeviceLocation (See Cache Device Location

)

Read-only

Table 837. Cache Device Status State

Name cacheDeviceStatusState

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.40.1.9

Defines the status state of the cache device.

DellCacheDeviceStatusState (See

Cache Device Status State

)

Read-only

Table 838. Cache Device External Socket Name

Name

Object ID

Description

Syntax

Access cacheDeviceExternalSocketName

1.3.6.1.4.1.674.10892.1.1100.40.1.10

Defines the external socket name of the cache device, if the cache is socketed.

DellString

Read-only

Table 839. Cache Device Level

Name

Object ID

Description

Syntax

Access cacheDeviceLevel

1.3.6.1.4.1.674.10892.1.1100.40.1.11

Defines the level of the cache device.

DellCacheDeviceLevel (See

Cache Device Level )

Read-only

Server Administrator Group 185

Table 840. Cache Device Maximum Size

Name

Object ID

Description

Syntax

Access cacheDeviceMaximumSize

1.3.6.1.4.1.674.10892.1.1100.40.1.12

Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown.

DellUnsigned32BitRange

Read-only

Table 841. Cache Device Current Size

Name

Object ID

Description

Syntax

Access cacheDeviceCurrentSize

1.3.6.1.4.1.674.10892.1.1100.40.1.13

Defines the current size of the cache device in KB. A zero (0) indicates that the size is unknown.

DellUnsigned32BitRange

Read-only

Table 842. Cache Device Speed

Name

Object ID

Description

Syntax

Access cacheDeviceSpeed

1.3.6.1.4.1.674.10892.1.1100.40.1.14

Defines the speed of the cache device in nanoseconds. A zero (0) indicates that the speed is unknown.

DellUnsigned32BitRange

Read-only

Table 843. Cache Device Write Policy

Name

Object ID

Description

Syntax

Access cacheDeviceWritePolicy

1.3.6.1.4.1.674.10892.1.1100.40.1.15

Defines the write policy of the cache device.

DellCacheDeviceWritePolicy (See Cache Device Write Policy

)

Read-only

Table 844. Cache Device Is Socketed

Name

Object ID

Description

Syntax

Access cacheDeviceIsSocketed

1.3.6.1.4.1.674.10892.1.1100.40.1.16

Defines if the cache device is socketed.

DellBoolean

Read-only

Table 845. Cache Device Error Checking and Correction (ECC) Type

Name

Object ID

Description

Syntax cacheDeviceECCType

1.3.6.1.4.1.674.10892.1.1100.40.1.17

Defines the type of error correction in use by the cache device.

DellCacheDeviceECCType (See Cache Device ECC Type )

186 Server Administrator Group

Table 845. Cache Device Error Checking and Correction (ECC) Type (continued)

Access Read-only

Table 846. Cache Device Associativity

Name

Object ID

Description

Syntax

Access cacheDeviceAssociativity

1.3.6.1.4.1.674.10892.1.1100.40.1.18

Defines the type of associativity in use by the cache device.

DellCacheDeviceAssociativity (See

Cache Device Associativity

)

Read-only

Table 847. Cache Device Supported Type

Name

Object ID

Description

Syntax

Access cacheDeviceSupportedType

1.3.6.1.4.1.674.10892.1.1100.40.1.19

Defines the type of static random-access memory (SRAM) that the cache device can support.

DellCacheDeviceSupportedType

Read-only

Table 848. Cache Device Current Type

Name

Object ID

Description

Syntax

Access cacheDeviceCurrentType

1.3.6.1.4.1.674.10892.1.1100.40.1.20

Defines the current type of SRAM for the cache device.

DellCacheDeviceSRAMType (See Cache Device Static Random-Access Memory

(SRAM) Type )

Read-only

Memory Device Table

Table 849. Memory Device Table

Name

Object ID

Description

Syntax

Access memoryDeviceTable

1.3.6.1.4.1.674.10892.1.1100.50

Defines the Memory Device Table.

SEQUENCE OF MemoryDeviceTableEntry

Not accessible

Table 850. Memory Device Table Entry

Name

Object ID

Description

Syntax

Access

Index memoryDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.50.1

Defines the Memory Device Table entry.

MemoryDeviceTableEntry

Not accessible memoryDevicechassisIndex

Server Administrator Group 187

Table 850. Memory Device Table Entry (continued)

, memoryDeviceIndex

Table 851. Memory Device Chassis Index

Name memoryDevicechassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.50.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 852. Memory Device Index

Name

Object ID

Description

Syntax

Access memoryDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.50.1.2

Defines the index of the memory device in this chassis.

DellObjectRange

Read-only

Table 853. Memory Device State Capabilities

Name

Object ID

Description

Syntax

Access memoryDeviceStateCapabilities

1.3.6.1.4.1.674.10892.1.1100.50.1.3

Defines the capabilities of the memory device.

DellStateCapabilities

Read-only

Table 854. Memory Device State Settings

Name

Object ID

Description

Syntax

Access memoryDeviceStateSettings

1.3.6.1.4.1.674.10892.1.1100.50.1.4

Defines the state of the memory device.

DellStateSettings

Read-only

Table 855. Memory Device Status

Name

Object ID

Description

Syntax

Access memoryDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.50.1.5

Defines the status of the memory device.

DellStatus

Read-only

Table 856. Memory Device Memory Port Index Reference

Name

Object ID memoryDeviceMemoryPortIndexReference

1.3.6.1.4.1.674.10892.1.1100.50.1.6

188 Server Administrator Group

Table 856. Memory Device Memory Port Index Reference (continued)

Description

Syntax

Access

Defines the index of the memory port of which this memory device is part.

DellObjectRange

Read-only

Table 857. Memory Device Type

Name

Object ID

Description

Syntax

Access memoryDeviceType

1.3.6.1.4.1.674.10892.1.1100.50.1.7

Defines the type of the memory device.

DellMemoryDeviceType (See Memory Device Type

)

Read-only

Table 858. Memory Device Location Name

Name

Object ID

Description

Syntax

Access memoryDeviceLocationName

1.3.6.1.4.1.674.10892.1.1100.50.1.8

Defines the location name of the memory device.

DellString

Read-only

Table 859. Memory Device Error Count

NOTE:

Memory Device Failure Modes

has now replaced this attribute. Memory Device Error Count is no longer in use. If you use the Memory Device Error Count attribute, the value returned is always zero, and using the attribute has no effect.

Name

Object ID

Description

Syntax

Access memoryDeviceErrorCount

1.3.6.1.4.1.674.10892.1.1100.50.1.9

Defines the total number of Error Checking and Correction (ECC) errors detected by the memory device. Writing a 0 (zero) to this variable resets the devices error counts.

DellSigned32BitRange

Read-only

Table 860. Memory Device Bank Location Name

Name

Object ID

Description

Syntax

Access memoryDeviceBankLocationName

1.3.6.1.4.1.674.10892.1.1100.50.1.10

Defines the bank location name of the memory device.

DellString

Read-only

Table 861. Memory Device Type Details

Name

Object ID

Description

Syntax

Access memoryDeviceTypeDetails

1.3.6.1.4.1.674.10892.1.1100.50.1.11

Defines the detailed type of the memory device.

DellMemoryDeviceTypeDetails (See

Memory Device Type Details )

Read-only

Server Administrator Group 189

Table 862. Memory Device Form Factor

Name

Object ID

Description

Syntax

Access memoryDeviceFormFactor

1.3.6.1.4.1.674.10892.1.1100.50.1.12

Defines the form factor of the memory device.

DellMemoryDeviceFormFactor (See

Memory Device Type Form Factor )

Read-only

Table 863. Memory Device Set

Name

Object ID

Description

Syntax

Access memoryDeviceSet

1.3.6.1.4.1.674.10892.1.1100.50.1.13

Defines if the memory device is a part of a set. A zero (0) indicates that this device is not part of a set.

DellUnsigned32BitRange

Read-only

Table 864. Memory Device Size

NOTE: memoryDeviceSize is no longer in use. This attribute is deprecated and replaced by memoryDeviceExtendedSize .

Name

Object ID

Description

Syntax

Access memoryDeviceSize

1.3.6.1.4.1.674.10892.1.1100.50.1.14

Defines the size in KB of the memory device.

DellUnsigned32BitRange

Read-only

Table 865. Memory Device Speed

Name

Object ID

Description

Syntax

Access memoryDeviceSpeed

1.3.6.1.4.1.674.10892.1.1100.50.1.15

Defines the attribute defines the maximum capable speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed.

DellUnsigned32BitRange

Read-only

Table 866. Memory Device Total Bus Width

Name

Object ID

Description

Syntax

Access memoryDeviceTotalBusWidth

1.3.6.1.4.1.674.10892.1.1100.50.1.16

Defines the total number of bits, including ECC, used by the memory device.

DellUnsigned32BitRange

Read-only

Table 867. Memory Device Total Data Bus Width

Name

Object ID

Description memoryDeviceTotalDataBusWidth

1.3.6.1.4.1.674.10892.1.1100.50.1.17

Defines the total number of data bits used by the memory device.

190 Server Administrator Group

Table 867. Memory Device Total Data Bus Width (continued)

Syntax

Access

DellUnsigned32BitRange

Read-only

Table 868. Memory Device Correctable Memory Event Count

NOTE:

Memory Device Failure Modes

has now replaced this attribute. Memory Device Correctable Memory Event Count is no longer used. If you use the Memory Device Correctable Memory Event Count attribute, the value returned is always zero, and using the attribute has no effect.

Name

Object ID

Description

Syntax

Access memoryDeviceSingleBitErrorCount

1.3.6.1.4.1.674.10892.1.1100.50.1.18

Defines the total number of Correctable Memory Events detected by the memory device.

DellSigned32BitRange

Read-only

Table 869. Memory Device Uncorrectable Memory Event Count

NOTE:

Memory Device Failure Modes

has now replaced this attribute. Memory Device Uncorrectable Memory Event

Count is no longer used. If you use the Memory Device Uncorrectable Memory Event Count attribute, the value returned is always zero, and using the attribute has no effect.

Name

Object ID

Description

Syntax

Access memoryDeviceMultiBitErrorCount

1.3.6.1.4.1.674.10892.1.1100.50.1.19

Defines the total number of Uncorrectable Memory Events detected by the memory device.

DellSigned32BitRange

Read-only

Table 870. Memory Device Failure Modes

Name

Object ID

Description

Syntax

Access memoryDeviceFailureModes

1.3.6.1.4.1.674.10892.1.1100.50.1.20

Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK. It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks.

DellMemoryDeviceFailureModes

Read-only

Table 871. Memory Device Manufacturer Name

Name

Object ID

Description

Syntax

Access memoryDeviceManufacturerName

1.3.6.1.4.1.674.10892.1.1100.50.1.21

Defines the manufacturer of the memory device.

DellString

Read-only

Table 872. Memory Device Part Number Name

Name

Object ID memoryDevicePartNumberName

1.3.6.1.4.1.674.10892.1.1100.50.1.22

Server Administrator Group 191

Table 872. Memory Device Part Number Name (continued)

Description

Syntax

Access

Defines the manufacturer's part number for the memory device.

DellString

Read-only

Table 873. Memory Device Serial Number Name

Name

Object ID

Description

Syntax

Access memoryDeviceSerialNumberName

1.3.6.1.4.1.674.10892.1.1100.50.1.23

Defines the serial number of the memory device.

DellString

Read-only

Table 874. Memory Device Asset Tag Name

Name

Object ID

Description

Syntax

Access memoryDeviceAssetTagName

1.3.6.1.4.1.674.10892.1.1100.50.1.24

Defines the asset tag of the memory device.

DellString

Read-only

Table 875. Memory Device Speed Name

Name

Object ID

Description

Syntax

Access memoryDeviceSpeedName

1.3.6.1.4.1.674.10892.1.1100.50.1.25

This attribute defines the speed of the memory device in string format with units specified in string.

DellString

Read-only

Table 876. Memory Device Rank

Name

Object ID

Description memoryDeviceRank

1.3.6.1.4.1.674.10892.1.1100.50.1.26

This attribute defines the Rank of the memory device (DIMM).

Value deviceRankIsU nknown(1) deviceRankIsS ingle(2) deviceRankIsD ual(4) deviceRankIsQ uad(8) deviceRankIsO ctal(16) deviceRankIsH exa(32)

Meaning

Rank is unknown

Rank is Single

Rank is Dual

Rank is Quad

Rank is Octal

Rank is Hexa

192 Server Administrator Group

Table 876. Memory Device Rank (continued)

Syntax

Access

DellMemoryDeviceRank

Read-only

Table 877. Memory Device Extended Size

NOTE: This attribute replaces the memoryDeviceExtendedSize .

Name

Object ID

Description

Syntax

Access memoryDeviceExtendedSize

1.3.6.1.4.1.674.10892.1.1100.50.1.27

This attribute defines the size in MBytes of the memory device.

DellUnsigned32BitRange

Read-only

Table 878. Memory Device Memory Technology

Name

Object ID

Description

Syntax

Access memoryDeviceMemoryTechnology

1.3.6.1.4.1.674.10892.1.1100.50.1.28

Defines the Memory technology type of the memory device.

DellMemoryDeviceMemoryTechnology

Read-only

Table 879. Memory Device Non-Volatile Size

Name

Object ID

Description

Syntax

Access memoryDeviceNonVolatileSize

1.3.6.1.4.1.674.10892.1.1100.50.1.29

Defines the size of the Non-volatile portion of the memory device in Mega Bytes (MB).

DellUnsigned32BitRange

Read-only

Table 880. Memory Device Volatile Size

Name

Object ID

Description

Syntax

Access memoryDeviceVolatileSize

1.3.6.1.4.1.674.10892.1.1100.50.1.30

Defines the size of the Volatile portion of the memory device in Mega Bytes (MB).

DellUnsigned32BitRange

Read-only

Table 881. Memory Device Cache Size

Name

Object ID

Description

Syntax

Access memoryDeviceCacheSize

1.3.6.1.4.1.674.10892.1.1100.50.1.31

Defines the size of the Cache portion of the memory device in Mega Bytes (MB).

DellUnsigned32BitRange

Read-only

Table 882. Memory Device Wear Level

Name memoryDeviceWearLevel

Server Administrator Group 193

Table 882. Memory Device Wear Level (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.50.1.32

Defines the Remaining Rated Write Endurance of the memory device.

DellUnsigned32BitRange

Read-only

NOTE: This attribute is applicable only for Non-Volatile family (NVDIMM-F, NVDIMM-N, NVDIMM-P and Intel Persistent

Memory) of Memory devices. For other technology devices (DRAM) this attribute would be reported as 255 (0xFF) which can be ignored.

Memory Device Mapped Address Table

Table 883. Memory Device Mapped Address Table

Name

Object ID

Description

Syntax

Access memoryDeviceMappedAddressTable

1.3.6.1.4.1.674.10892.1.1100.60

Defines the Memory Device Mapped Address Table.

SEQUENCE OF MemoryDeviceMappedAddressTableEntry

Not accessible

Table 884. Memory Device Mapped Address Table Entry

Name

Object ID

Description

Syntax

Access

Index memoryDeviceMappedAddressTableEntry

1.3.6.1.4.1.674.10892.1.1100.60.1

Defines the Memory Device Mapped Address Table entry.

MemoryDeviceMappedAddressTableEntry

Not accessible memoryDeviceMappedAddresschassisIndex

, memoryDeviceMappedAddressIndex

Table 885. Memory Device Mapped Address Chassis Index

Name

Object ID

Description

Syntax

Access memoryDeviceMappedAddresschassisIndex

1.3.6.1.4.1.674.10892.1.1100.60.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 886. Memory Device Mapped Address Index

Name memoryDeviceMappedAddressIndex

Object ID

Description

Syntax

1.3.6.1.4.1.674.10892.1.1100.60.1.2

Defines the index (one-based) of the memory device mapped address in this chassis.

DellObjectRange

194 Server Administrator Group

Table 886. Memory Device Mapped Address Index (continued)

Access Read-only

Table 887. Memory Device Mapped Address State Capabilities

Name

Object ID

Description

Syntax

Access memoryDeviceMappedAddressStateCapabilities

1.3.6.1.4.1.674.10892.1.1100.60.1.3

Defines the capabilities of the memory device mapped address.

DellStateCapabilities

Read-only

Table 888. Memory Device Mapped Address State Settings

Name

Object ID

Description

Syntax

Access memoryDeviceMappedAddressStateSettings

1.3.6.1.4.1.674.10892.1.1100.60.1.4

Defines the state of the memory device mapped address.

DellStateSettings

Read-only

Table 889. Memory Device Mapped Address Status

Name memoryDeviceMappedAddressStatus

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.60.1.5

Defines the status of the memory device mapped address.

DellStatus

Read-only

Table 890. Memory Device Index Reference

Name

Object ID

Description

Syntax

Access memoryDeviceIndexReference

1.3.6.1.4.1.674.10892.1.1100.60.1.6

Defines the index of the memory device(s) associated with this memory device mapped address.

DellObjectRange

Read-only

Table 891. Memory Device Mapped Address Row Position

Name

Object ID

Description

Syntax

Access memoryDeviceMappedAddressRowPosition

1.3.6.1.4.1.674.10892.1.1100.60.1.7

Defines the position of the referenced memory in a row of the memory device mapped address.

DellUnsigned32BitRange

Read-only

Table 892. Memory Device Mapped Address Interleave Position

Name

Object ID memoryDeviceMappedAddressInterleavePosition

1.3.6.1.4.1.674.10892.1.1100.60.1.8

Server Administrator Group 195

Table 892. Memory Device Mapped Address Interleave Position (continued)

Description

Syntax

Access

Defines the position of the referenced memory in an interleave of the memory device mapped address.

DellUnsigned32BitRange

Read-only

Table 893. Memory Device Mapped Address Interleave Depth

Name

Object ID

Description

Syntax

Access memoryDeviceMappedAddressInterleaveDepth

1.3.6.1.4.1.674.10892.1.1100.60.1.9

Defines the maximum number of consecutive rows from the referenced memory device that are accessed in a single interleaved transfer in the memory device mapped address.

DellUnsigned32BitRange

Read-only

Table 894. Memory Device Mapped Address Starting Address

Name

Object ID

Description

Syntax

Access memoryDeviceMappedAddressStartingAddress

1.3.6.1.4.1.674.10892.1.1100.60.1.10

Defines the physical starting address in KB of the memory device mapped address.

DellUnsigned64BitRange

Read-only

Table 895. Memory Device Mapped Address Ending Address

Name

Object ID

Description

Syntax

Access memoryDeviceMappedAddressEndingAddress

1.3.6.1.4.1.674.10892.1.1100.60.1.11

Defines the physical ending address in KB of the memory device mapped address.

DellUnsigned64BitRange

Read-only

Generic Device Table

Table 896. Generic Device Table

Name

Object ID

Description

Syntax

Access genericDeviceTable

1.3.6.1.4.1.674.10892.1.1100.70

Defines the Generic Device Table.

SEQUENCE OF GenericDeviceTableEntry

Not accessible

Table 897. Generic Device Table Entry

Name

Object ID

Description

Syntax

Access genericDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.70.1

Defines the Generic Device Table entry.

GenericDeviceTableEntry

Not accessible

196 Server Administrator Group

Table 897. Generic Device Table Entry (continued)

Index genericDevicechassisIndex

, genericDeviceIndex

Table 898. Generic Device Chassis Index

Name

Object ID

Description

Syntax

Access genericDevicechassisIndex

1.3.6.1.4.1.674.10892.1.1100.70.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 899. Generic Device Index

Name

Object ID

Description

Syntax

Access genericDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.70.1.2

Defines the index of the generic device in this chassis.

DellObjectRange

Read-only

Table 900. Generic Device State Capabilities

Name genericDeviceStateCapabilities

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.70.1.3

Defines the capabilities of the generic device.

DellStateCapabilities

Read-only

Table 901. Generic Device State Settings

Name

Object ID

Description

Syntax

Access genericDeviceStateSettings

1.3.6.1.4.1.674.10892.1.1100.70.1.4

Defines the state of the generic device.

DellStateSettings

Read-only

Table 902. Generic Device Status

Name

Object ID

Description

Syntax

Access genericDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.70.1.5

Defines the status of the generic device.

DellStatus

Read-only

Server Administrator Group 197

Table 903. Generic Device System Slot Index Reference

Name

Object ID

Description

Syntax

Access genericDeviceSystemSlotIndexReference

1.3.6.1.4.1.674.10892.1.1100.70.1.6

Defines the index of the system slot into which this generic device is plugged.

DellObjectRange

Read-only

Table 904. Generic Device Type

Name

Object ID

Description

Syntax

Access genericDeviceType

1.3.6.1.4.1.674.10892.1.1100.70.1.7

Defines the type of the generic device.

DellGenericDeviceType (See Generic Device Type

)

Read-only

Table 905. Generic Device Name

Name

Object ID

Description

Syntax

Access genericDeviceName

1.3.6.1.4.1.674.10892.1.1100.70.1.8

Defines the name of the generic device.

DellString

Read-only

PCI Device Table

Table 906. PCI Device Table

Name

Object ID

Description

Syntax

Access pCIDeviceTable

1.3.6.1.4.1.674.10892.1.1100.80

Defines the PCI Device Detail Table.

SEQUENCE OF PCIDeviceTableEntry

Not accessible

Table 907. PCI Device Table Entry

Name

Object ID

Description

Syntax

Access

Index pCIDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.80.1

Defines the PCI Device Table entry.

PCIDeviceTableEntry

Not accessible pCIDevicechassisIndex

, pCIDeviceIndex

198 Server Administrator Group

Table 908. PCI Device Chassis Index

Name

Object ID

Description

Syntax

Access pCIDevicechassisIndex

1.3.6.1.4.1.674.10892.1.1100.80.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 909. PCI Device Index

Name

Object ID

Description

Syntax

Access pCIDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.80.1.2

Defines the index (one-based) of the PCI device in this chassis.

DellObjectRange

Read-only

Table 910. PCI Device State Capabilities

Name

Object ID

Description

Syntax

Access pCIDeviceStateCapabilities

1.3.6.1.4.1.674.10892.1.1100.80.1.3

Defines the capabilities of the PCI device.

DellStateCapabilities

Read-only

Table 911. PCI Device State Settings

Name

Object ID

Description

Syntax

Access pCIDeviceStateSettings

1.3.6.1.4.1.674.10892.1.1100.80.1.4

Defines the state of the PCI device.

DellStateSettings

Read-only

Table 912. PCI Device Status

Name

Object ID

Description

Syntax

Access pCIDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.80.1.5

Defines the status of the PCI device.

DellStatus

Read-only

Table 913. PCI Device System Slot Index Reference

Name

Object ID

Description

Syntax

Access pCIDeviceSystemSlotIndexReference

1.3.6.1.4.1.674.10892.1.1100.80.1.6

Defines the index number of the system slot that this PCI device is in.

DellObjectRange

Read-only

Server Administrator Group 199

Table 914. PCI Device Data Bus Width

Name

Object ID

Description

Syntax

Access pCIDeviceDataBusWidth

1.3.6.1.4.1.674.10892.1.1100.80.1.7

Defines the bus width of the PCI device in this chassis.

DellUnsigned32BitRange

Read-only

Table 915. PCI Device Manufacturer Name

Name

Object ID

Description

Syntax

Access pCIDeviceManufacturerName

1.3.6.1.4.1.674.10892.1.1100.80.1.8

Defines the name of the PCI device manufacturer.

DellString

Read-only

Table 916. PCI Device Description Name

Name

Object ID

Description

Syntax

Access pCIDeviceDescriptionName

1.3.6.1.4.1.674.10892.1.1100.80.1.9

Defines the descriptive name of the PCI device.

DellString

Read-only

Table 917. PCI Device Speed

Name

Object ID

Description

Syntax

Access pCIDeviceSpeed

1.3.6.1.4.1.674.10892.1.1100.80.1.10

Defines the bus speed in MHz of the PCI device in this chassis. A zero (0) indicates that the speed is unknown.

DellUnsigned32BitRange

Read-only

Table 918. PCI Device Adapter Fault

Name

Object ID

Description

Syntax

Access pCIDeviceAdapterFault

1.3.6.1.4.1.674.10892.1.1100.80.1.11

Defines whether the PCI device in this chassis has detected a fault.

DellBoolean

Read-only

PCI Device Configuration Space Table

Table 919. PCI Device Configuration Space Table

Name

Object ID

Description

Syntax pCIDeviceConfigurationSpaceTable

1.3.6.1.4.1.674.10892.1.1100.82

Defines the PCI Device Configuration Table.

SEQUENCE OF PCIDeviceConfigurationSpaceTableEntry

200 Server Administrator Group

Table 919. PCI Device Configuration Space Table (continued)

Access Not accessible

Table 920. PCI Device Configuration Space Table Entry

Name

Object ID

Description

Syntax

Access

Index pCIDeviceConfigurationSpaceTableEntry

1.3.6.1.4.1.674.10892.1.1100.82.1

Defines the PCI Device Configuration Table entry.

PCIDeviceConfigurationSpaceTableEntry

Not accessible pCIDeviceConfigurationSpacechassisIndex

, pCIDeviceConfigurationSpaceIndex

Table 921. PCI Device Configuration Space Chassis Index

Name

Object ID

Description

Syntax

Access pCIDeviceConfigurationSpacechassisIndex

1.3.6.1.4.1.674.10892.1.1100.82.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 922. PCI Device Configuration Space Index

Name

Object ID

Description

Syntax

Access pCIDeviceConfigurationSpaceIndex

1.3.6.1.4.1.674.10892.1.1100.82.1.2

Defines the index (one-based) of the PCI device configuration in this chassis.

DellObjectRange

Read-only

Table 923. PCI Device Configuration Space State Capabilities

Name

Object ID

Description

Syntax

Access pCIDeviceConfigurationSpaceStateCapabilities

1.3.6.1.4.1.674.10892.1.1100.82.1.3

Defines the capabilities of the PCI device configuration.

DellStateCapabilities

Read-only

Table 924. PCI Device Configuration Space State Settings

Name pCIDeviceConfigurationSpaceStateSettings

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.82.1.4

Defines the state of the PCI device configuration.

DellStateSettings

Read-only

Server Administrator Group 201

Table 925. PCI Device Configuration Space Status

Name

Object ID

Description

Syntax

Access pCIDeviceConfigurationSpaceStatus

1.3.6.1.4.1.674.10892.1.1100.82.1.5

Defines the status of the PCI device configuration.

DellStatus

Read-only

Table 926. PCI Device Index Reference

Name

Object ID

Description

Syntax

Access pCIDeviceIndexReference

1.3.6.1.4.1.674.10892.1.1100.82.1.6

Defines the index number of PCI device that this configuration applies to.

DellObjectRange

Read-only

Table 927. PCI Device Configuration Space Bus Number

Name

Object ID

Description

Syntax

Access pCIDeviceConfigurationSpaceBusNumber

1.3.6.1.4.1.674.10892.1.1100.82.1.7

Defines the bus number of the PCI device configuration in this chassis.

DellUnsigned32BitRange

Read-only

Table 928. PCI Device Configuration Space Device Number

Name

Object ID

Description

Syntax

Access pCIDeviceConfigurationSpaceDeviceNumber

1.3.6.1.4.1.674.10892.1.1100.82.1.8

Defines the device number of the PCI device in this chassis.

DellUnsigned32BitRange

Read-only

Table 929. PCI Device Configuration Space Function Number

Name

Object ID

Description

Syntax

Access pCIDeviceConfigurationSpaceFunctionNumber

1.3.6.1.4.1.674.10892.1.1100.82.1.9

Defines the function number of the PCI device in this chassis.

DellUnsigned32BitRange

Read-only

Table 930. PCI Device Configuration Space Header

Name

Object ID

Description

Syntax

Access pCIDeviceConfigurationSpaceHeader

1.3.6.1.4.1.674.10892.1.1100.82.1.10

Defines the common configuration space header of the PCI device.

Octet String (SIZE(0.1025))

Read-only

202 Server Administrator Group

Network Device Table

Table 931. Network Device Table

Name

Object ID

Description

Syntax

Access networkDeviceTable

1.3.6.1.4.1.674.10892.1.1100.90

Defines the Network Device Table.

SEQUENCE OF NetworkDeviceTableEntry

Not accessible

Table 932. Network Device Table Entry

Name

Object ID

Description

Syntax

Access

Index networkDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.90.1

Defines the Network Device Table Entry.

NetworkDeviceTableEntry

Not accessible networkDeviceChassisIndex

, networkDeviceIndex

Table 933. Network Device Chassis Index

Name

Object ID

Description

Syntax

Access networkDeviceChassisIndex

1.3.6.1.4.1.674.10892.1.1100.90.1.1

Defines the index (one-based) of the chassis that contains the network device.

DellObjectRange

Read-only

Table 934. Network Device Index

Name

Object ID

Description

Syntax

Access networkDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.90.1.2

Defines the index (one-based) of the network device.

DellObjectRange

Read-only

Table 935. Network Device Status

Name

Object ID

Description

Syntax

Access networkDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.90.1.3

Defines the status of the network device.

DellStatus

Read-only

Server Administrator Group 203

Table 936. Network Device Connection Status

Name

Object ID

Description

Syntax

Access networkDeviceConnectionStatus

1.3.6.1.4.1.674.10892.1.1100.90.1.4

Defines the connection status of the network device.

DellNetworkDeviceConnectionStatus (See Network Device Connection Status )

Read-only

Table 937. Network Device Description Name

Name

Object ID

Description

Syntax

Access networkDeviceDescriptionName

1.3.6.1.4.1.674.10892.1.1100.90.1.5

Defines the description of the network device.

DellString

Read-only

Table 938. Network Device Product Name

Name

Object ID

Description

Syntax

Access networkDeviceProductName

1.3.6.1.4.1.674.10892.1.1100.90.1.6

Defines the product name of the network device.

DellString

Read-only

Table 939. Network Device Vendor Name

Name

Object ID

Description

Syntax

Access networkDeviceVendorName

1.3.6.1.4.1.674.10892.1.1100.90.1.7

Defines the name of the vendor of the network device.

DellString

Read-only

Table 940. Network Device Service Name

Name

Object ID

Description

Syntax

Access networkDeviceServiceName

1.3.6.1.4.1.674.10892.1.1100.90.1.8

Defines the service name of the network device.

DellString

Read-only

Table 941. Network Device Driver Image Path Name

Name

Object ID

Description

Syntax

Access networkDeviceDriverImagePathName

1.3.6.1.4.1.674.10892.1.1100.90.1.9

Defines the path to the binary image of the driver for the network device.

DellString

Read-only

204 Server Administrator Group

Table 942. Network Device Driver Version Name

Name

Object ID

Description

Syntax

Access networkDeviceDriverVersionName

1.3.6.1.4.1.674.10892.1.1100.90.1.10

Defines the version of the driver for the network device.

DellString

Read-only

Table 943. Network Device IP Address

Name

Object ID

Description

Syntax

Access networkDeviceIPAddress

1.3.6.1.4.1.674.10892.1.1100.90.1.11

Defines the IP address of the network device.

IpAddress

Read-only

Table 944. Network Device IP Subnet Mask

Name

Object ID

Description

Syntax

Access networkDeviceIPSubnetMask

1.3.6.1.4.1.674.10892.1.1100.90.1.12

Defines the IP subnet mask for the IP address currently assigned to the network device.

IpAddress

Read-only

Table 945. Network Device Default Gateway IP Address

Name

Object ID

Description

Syntax

Access networkDeviceDefaultGatewayIPAddress

1.3.6.1.4.1.674.10892.1.1100.90.1.13

Defines the IP address of the default gateway for the network device.

IpAddress

Read-only

Table 946. Network Device DHCP Server IP Address

Name

Object ID

Description

Syntax

Access networkDeviceDHCPServerIPAddress

1.3.6.1.4.1.674.10892.1.1100.90.1.14

Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the network device.

IpAddress

Read-only

Table 947. Network Device Current MAC Address

Name

Object ID

Description

Syntax

Access networkDeviceCurrentMACAddress

1.3.6.1.4.1.674.10892.1.1100.90.1.15

Defines the current MAC address of the network device.

DellMACAddress

Read-only

Server Administrator Group 205

Table 948. Network Device Permanent MAC Address

Name

Object ID

Description

Syntax

Access networkDevicePermanentMACAddress

1.3.6.1.4.1.674.10892.1.1100.90.1.16

Defines the permanent MAC address of the network device.

DellMACAddress

Read-only

Table 949. Network Device PCI Bus Number

Name

Object ID

Description

Syntax

Access networkDevicePCIBusNumber

1.3.6.1.4.1.674.10892.1.1100.90.1.17

Defines the PCI bus number of the network device.

DellUnsigned8BitRange

Read-only

Table 950. Network Device PCI Device Number

Name

Object ID

Description

Syntax

Access networkDevicePCIDeviceNumber

1.3.6.1.4.1.674.10892.1.1100.90.1.18

Defines the PCI device number of the network device.

DellUnsigned8BitRange

Read-only

Table 951. Network Device PCI Function Number

Name

Object ID

Description

Syntax

Access networkDevicePCIFunctionNumber

1.3.6.1.4.1.674.10892.1.1100.90.1.19

Defines the PCI function number of the network device.

DellUnsigned8BitRange

Read-only

Table 952. Network Device IRQ

Name

Object ID

Description

Syntax

Access networkDeviceIRQ

1.3.6.1.4.1.674.10892.1.1100.90.1.20

Defines the interrupt request number of the network device.

DellUnsigned32BitRange

Read-only

Table 953. Network Device Base IO Port Address

Name

Object ID

Description

Syntax

Access networkDeviceBaseIOPortAddress

1.3.6.1.4.1.674.10892.1.1100.90.1.21

Defines the base input/output port address of the network device.

DellUnsigned32BitRange

Read-only

206 Server Administrator Group

Table 954. Network Device Teaming Flags

Name

Object ID

Description

Syntax

Access networkDeviceTeamingFlags

1.3.6.1.4.1.674.10892.1.1100.90.1.22

Defines the teaming features of the network device.

DellNetworkDeviceTeamingFlags (See Network Device Teaming Flags )

Read-only

Table 955. Network Device TOE Capability Flags

Name

Object ID

Description

Syntax

Access networkDeviceTOECapabilityFlags

1.3.6.1.4.1.674.10892.1.1100.90.1.23

Defines the TCP/IP Offload Engine (TOE) capability flags of the network device.

DellNetworkDeviceTOECapabilityFlags (See

Network Device TOE Capability Flags

)

Read-only

Table 956. Network Device TOE Enabled

Name

Object ID

Description

Syntax

Access networkDeviceTOEEnabled

1.3.6.1.4.1.674.10892.1.1100.90.1.24

Defines if TOE is enabled for the network device.

DellBoolean

Read-only

Table 957. Network Device RDMA Capability Flags

Name

Object ID

Description

Syntax

Access networkDeviceRDMACapabilityFlags

1.3.6.1.4.1.674.10892.1.1100.90.1.25

Defines the Remote Direct Memory Access (RDMA) capability flags of the network device.

DellNetworkDeviceRDMACapabilityFlags (See Network Device RDMA Capability Flags

)

Read-only

Table 958. Network Device RDMA Enabled

Name

Object ID

Description

Syntax

Access networkDeviceRDMAEnabled

1.3.6.1.4.1.674.10892.1.1100.90.1.26

Defines if RDMA is enabled for the network device.

DellBoolean

Read-only

Table 959. Network Device iSCSI Capability Flags

Name

Object ID

Description

Syntax

Access networkDeviceiSCSICapabilityFlags

1.3.6.1.4.1.674.10892.1.1100.90.1.27

Defines the Internet Small Computer System Interface (iSCSI) capability flags of the network device.

DellNetworkDeviceiSCSICapabilityFlags (See

Network Device iSCSI Capability Flags )

Read-only

Server Administrator Group 207

Table 960. Network Device iSCSI Enabled

Name

Object ID

Description

Syntax

Access networkDeviceiSCSIEnabled

1.3.6.1.4.1.674.10892.1.1100.90.1.28

Defines if iSCSI is enabled for the network device.

DellBoolean

Read-only

Table 961. Network Device Capabilities

Name

Object ID

Description

Syntax

Access networkDeviceCapabilities

1.3.6.1.4.1.674.10892.1.1100.90.1.29

Defines the capabilities of the network device.

DellNetworkDeviceCapabilities (See

Network Device Capabilities

)

Read-only

Table 962. Network Device NParEP Enabled

Name

Object ID

Description networkDeviceNParEPEnabled

1.3.6.1.4.1.674.10892.1.1100.90.1.30

Defines if NParEP mode is enabled for the network device.

The values for the NParEPEnabled are:

1 - Disabled

2 - Enabled

3 - Unknown

Syntax

Access

DellNetworkDeviceNParEPEnabled

Read-only

Managed System Services Device Table

Table 963. Managed System Services Device Table

Name

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.100

Defines the Managed System Services Device Table.

Sequence of ManagedSystemServicesDeviceTable

Not accessible

Table 964. Managed System Services Device Table Entry

Name

Object ID

Description

Syntax

Access

Index managedSystemServicesDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.100.1

Defines the managed system services device table entry.

ManagedSystemServicesDeviceTableEntry

Not accessible managedSystemServicesDeviceChassisIndex

208 Server Administrator Group

Table 964. Managed System Services Device Table Entry (continued)

, managedSystemServicesDeviceIndex

Table 965. Managed System Services Device Chassis Index

Name managedSystemServicesDeviceChassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.100.1.1

Defines the index (one-based) of the chassis that contains the managed system services device.

DellObjectRange

Read-only

Table 966. Managed System Services Device Index

Name

Object ID

Description

Syntax

Access managedSystemServicesDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.100.1.2

Defines the index (one-based) of the managed system services device.

DellObjectRange

Read-only

Table 967. Managed System Services Device Status

Name

Object ID

Description

Syntax

Access managedSystemServicesDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.100.1.3

Defines the status of the managed system services device.

DellStatus

Read-only

Table 968. Managed System Services Device Type

Name

Object ID

Description

Syntax

Access managedSystemServicesDeviceType

1.3.6.1.4.1.674.10892.1.1100.100.1.4

Defines the type of the managed system services device.

DellManagedSystemServicesDeviceType (See

Managed System Services Device Type

)

Read-only

Table 969. Managed System Services Device Storage Present

Name

Object ID

Description

Syntax

Access managedSystemServicesDeviceStoragePresent

1.3.6.1.4.1.674.10892.1.1100.100.1.5

Defines whether storage is present on the managed system services device.

DellBoolean

Read-only

Table 970. Managed System Services Device Storage Size

Name

Object ID managedSystemServicesDeviceStorageSize

1.3.6.1.4.1.674.10892.1.1100.100.1.6

Server Administrator Group 209

Table 970. Managed System Services Device Storage Size (continued)

Description

Syntax

Access

Defines the size in Megabytes (MB) of the storage present on the managed system services device.

DellUnsigned32BitRange

Read-only

SD Card Unit Table

Table 971. SD Card Unit Table

Name

Object ID

Description

Syntax

Access sdCardUnitTable

1.3.6.1.4.1.674.10892.1.1100.110

Defines the SD Card Unit Table.

SEQUENCE OF SdCardUnitTableEntry

Not accessible

Table 972. SD Card Unit Table Entry

Name

Object ID

Description

Syntax

Access

Index sdCardUnitTableEntry

1.3.6.1.4.1.674.10892.1.1100.110.1

Defines the SD Card Unit Table Entry.

SdCardUnitTableEntry

Not accessible sdCardUnitChassisIndex

, sdCardUnitIndex

Table 973. SD Card Unit Chassis Index

Name

Object ID

Description

Syntax

Access sdCardUnitChassisIndex

1.3.6.1.4.1.674.10892.1.1100.110.1.1

Defines the index (one-based) of the chassis that contains the SD Card unit.

DellObjectRange

Read-only

Table 974. SD Card Unit Index

Name

Object ID

Description

Syntax

Access sdCardUnitIndex

1.3.6.1.4.1.674.10892.1.1100.110.1.2

Defines the index (one-based) of the SD Card unit.

DellObjectRange

Read-only

Table 975. SD Card Unit State Capabilities

Name sdCardUnitStateCapabilities

210 Server Administrator Group

Table 975. SD Card Unit State Capabilities (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1100.110.1.3

Defines the state capabilities of the SD Card unit.

DellStateCapabilities

Read-only

Table 976. SD Card Unit State Settings

Name

Object ID

Description

Syntax

Access sdCardUnitStateSettings

1.3.6.1.4.1.674.10892.1.1100.110.1.4

Defines the state settings of the SD Card unit.

DellStateSettings

Read-only

Table 977. SD Card Unit Redundancy Status

Name

Object ID

Description

Syntax

Access sdCardUnitRedundancyStatus

1.3.6.1.4.1.674.10892.1.1100.110.1.5

Defines the redundancy status of the SD Card unit.

DellStatusRedundancy

Read-only

Table 978. SD Card Unit Count For Redundancy

Name

Object ID

Description

Syntax

Access sdCardUnitCountForRedundancy

1.3.6.1.4.1.674.10892.1.1100.110.1.6

Defines the total number of SD Card devices required for this SD Card unit to have full redundancy.

DellObjectRange

Read-only

Table 979. SD Card Unit Name

Name

Object ID

Description

Syntax

Access sdCardUnitName

1.3.6.1.4.1.674.10892.1.1100.110.1.7

Defines the name of the SD Card unit.

DellString

Read-only

Table 980. SD Card Unit Status

Name

Object ID

Description

Syntax

Access sdCardUnitStatus

1.3.6.1.4.1.674.10892.1.1100.110.1.8

Defines the status of the SD Card unit.

DellStatus

Read-only

Server Administrator Group 211

SD Card Device Table

Table 981. SD Card Device Table

Name

Object ID

Description

Syntax

Access sdCardDeviceTable

1.3.6.1.4.1.674.10892.1.1100.112

Defines the SD Card Device Table.

SEQUENCE OF SdCardDeviceTableEntry

Not accessible

Table 982. SD Card Device Table Entry

Name

Object ID

Description

Syntax

Access

Index sdCardDeviceTableEntry

1.3.6.1.4.1.674.10892.1.1100.112.1

Defines the SD Card Device Table Entry.

SdCardDeviceTableEntry

Not accessible sdCardDeviceChassisIndex

, sdCardDeviceIndex

Table 983. SD Card Device Chassis Index

Name

Object ID

Description

Syntax

Access sdCardDeviceChassisIndex

1.3.6.1.4.1.674.10892.1.1100.112.1.1

Defines the index (one-based) of the chassis that contains the SD Card device.

DellObjectRange

Read-only

Table 984. SD Card Device Index

Name

Object ID

Description

Syntax

Access sdCardDeviceIndex

1.3.6.1.4.1.674.10892.1.1100.112.1.2

Defines the index (one-based) of the SD Card device.

DellObjectRange

Read-only

Table 985. SD Card Device Status

Name

Object ID

Description

Syntax

Access sdCardDeviceStatus

1.3.6.1.4.1.674.10892.1.1100.112.1.3

Defines the status of the SD Card device.

DellStatus

Read-only

212 Server Administrator Group

Table 986. SD Card Device Type

Name

Object ID

Description

Syntax

Access sdCardDeviceType

1.3.6.1.4.1.674.10892.1.1100.112.1.4

Defines the type of the SD Card device.

DellSDCardDeviceType

Read-only

Table 987. SD Card Device Config Capabilities

Name

Object ID

Description

Syntax

Access sdCardDeviceConfigCapabilities

1.3.6.1.4.1.674.10892.1.1100.112.1.5

Defines the configuration capabilities of the SD Card device.

DellSDCardDeviceConfigCapabilities

Read-only

Table 988. SD Card Device Config Settings

Name

Object ID

Description

Syntax

Access sdCardDeviceConfigSettings

1.3.6.1.4.1.674.10892.1.1100.112.1.6

Defines the configuration settings of the SD Card device.

DellSDCardDeviceConfigSettings

Read-only

Table 989. SD Card Device Location Name

Name

Object ID

Description

Syntax

Access sdCardDeviceLocationName

1.3.6.1.4.1.674.10892.1.1100.112.1.7

Defines the location of the SD Card device.

DellString

Read-only

Table 990. SD Card Device Card Present

Name

Object ID

Description

Syntax

Access sdCardDeviceCardPresent

1.3.6.1.4.1.674.10892.1.1100.112.1.8

Defines whether the SD Card is present for the SD Card device.

DellBoolean

Read-only

Table 991. SD Card Device Card State

Name

Object ID

Description

Syntax

Access sdCardDeviceCardState

1.3.6.1.4.1.674.10892.1.1100.112.1.9

Defines the state of the SD Card.

DellSDCardDeviceCardState

Read-only

Server Administrator Group 213

Table 992. SD Card Device Card Storage Size

Name

Object ID

Description

Syntax

Access sdCardDeviceCardStorageSize

1.3.6.1.4.1.674.10892.1.1100.112.1.10

Defines the storage size in MB (megabytes) of the SD card for the SD Card device.

DellUnsigned32BitRange

Read-only

Table 993. SD Card Device Unit Index Reference

Name

Object ID

Description

Syntax

Access sdCardDeviceUnitIndexReference

1.3.6.1.4.1.674.10892.1.1100.112.1.11

Defines the index to the associated SD Card unit if the SD Card device is part of a SD

Card unit.

DellObjectRange

Read-only

Table 994. SD Card Device Card Available Storage Size

Name

Object ID

Description

Syntax

Access sdCardDeviceCardAvailableStorageSize

1.3.6.1.4.1.674.10892.1.1100.112.1.12

Defines the available storage size in MB (megabytes) of the SD card for the SD card device.

DellSigned32BitRange

Read-only

Table 995. SD Card Device Card Licensed

Name

Object ID

Description

Syntax

Access sdCardDeviceCardLicensed

1.3.6.1.4.1.674.10892.1.1100.112.1.13

Defines whether the SD card is licensed by the system vendor.

DellSDCardDeviceCardLicensed

Read-only

Device Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 996. Pointing Device Type

Variable Name: DellPointingDeviceType

Data Type: Integer

Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2

)

Device type is unknown.

deviceTypeIsAMouse(3) Device type is a mouse.

deviceTypeIsATrackBal l(4)

Device type is a track ball.

214 Server Administrator Group

Table 996. Pointing Device Type (continued) deviceTypeIsATrackPoi nt(5) deviceTypeIsAGlidePoi nt(6) deviceTypeIsATouchPad

(7)

Device type is a track point.

Device type is a glide point.

Device type is a touch pad.

Table 997. Processor Device Status State

Variable Name: DellProcessorDeviceStatusState

Data Type: Integer

Possible Data Values other(1) unknown(2) enabled(3) userDisabled(4) biosDisabled(5) idle(6)

Meaning of Data Value

Processor device type is not one of the following:

Device type is unknown.

Device is enabled.

Device is disabled by the user.

Device has its BIOS disabled.

Device is idle.

Table 998. Processor Device Status Reading

Variable Name: DellProcessorDeviceStatusReading

Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.

Possible Data Values internalError(1) thermalTrip(2) configurationError(

32) processorPresent(12

8) processorDisabled(2

56) terminatorPresent(5

12) processorThrottled(

1024)

Meaning of Data Value

The processor experienced an internal error

The processor experienced a thermal trip

The processor experienced a configuration error

The processor is present

The processor is disabled

The terminator is Present

The processor is throttled

Table 999. Processor Device Type

Variable Name: DellProcessorDeviceType

Data Type: Integer

Possible Data Values deviceTypeIsOther(1

)

Meaning of Data Value

The processor device type is not one of the following values:

Server Administrator Group 215

Table 999. Processor Device Type (continued) deviceTypeIsUnknown

(2)

The processor device type is unknown.

deviceTypeIsCPU(3) The processor device type is a central processing unit.

deviceTypeIsMathPro cessor(4)

The processor device type is a math processor.

deviceTypeIsDSP(5) The processor device type is a digital signal processor.

deviceTypeIsAVideoP rocessor(6)

The processor device is a video processor.

Table 1000. Processor Upgrade Information

Variable Name: DellProcessorUpgradeInformation

Data Type: Integer

Possible Data Values deviceTypeIsOther(1

) processorUpgradeIsU nknown(2) processorUpgradeIsB yDaughterBoard(3) processorUpgradeIsB yZIFSocket(4) processorUpgradeIsB yReplacement(5) processorUpgradeIsN one(6) processorUpgradeIsB yLIFSocket(7) processorUpgradeIsB ySlot1(8) processorUpgradeIsB ySlot2(9) processorUpgradeIsB y370PinSocket(10) processorUpgradeIsB ySlotA(11) processorUpgradeIsB ySlotM(12) processorUpgradeIsB yScoket423(13) processorUpgradeIsB ySocketA(14) processorUpgradeIsB ySocket478(15) processorUpgradeIsB ySocket754(16)

Meaning of Data Value

The upgrade device type is not one of the following:

Upgrade device type is unknown.

Upgrade device is on a daughter board.

Upgrade device is in a zero insertion force (ZIF) socket.

Upgrade device is a replacement.

There is no upgrade device.

Upgrade device is in a low insertion force (LIF) socket.

Upgrade device is a SLOT 1 processor.

Upgrade device is a SLOT 2 processor.

Upgrade device is a 370 pin socket.

Upgrade is by Slot A.

Upgrade is by Slot M.

Upgrade is by Socket 423.

Upgrade is by Socket A (Socket 462).

Upgrade is by Socket 478.

Upgrade is by Socket 754.

216 Server Administrator Group

Table 1000. Processor Upgrade Information (continued) processorUpgradeIsB ySocket940(17) processorUpgradeIsB ySocket939(18) processorUpgradeIsB ySocketmPGA604(19) processorUpgradeIsB ySocketLGA771(20) processorUpgradeIsB ySocketLGA775(21) processorUpgradeIsB ySocketS1(22) processorUpgradeIsB ySocketAM2(23) processorUpgradeIsB ySocketF(24) processorUpgradeIsB ySocketLGA1366(25)

Upgrade is by Socket 940.

Upgrade is by Socket 939.

Upgrade is by Socket mPGA604.

Upgrade is by Socket LGA771.

Upgrade is by Socket LGA775.

Upgrade is by Socket S1.

Upgrade is by Socket AM2.

Upgrade is by Socket F (1207).

Upgrade is by Socket LGA1366.

Table 1001. Processor Device Family

Variable Name: DellProcessorDeviceFamily

Data Type: Integer

Possible Data Values deviceFamilyIsOther(1) deviceFamilyUnknown(2) deviceFamilyIs8086(3) deviceFamilyIs80286(4)

Meaning of Data Value

The processor family is not one of the following values.

The processor family is unknown.

The processor family is 8086.

The processor family is 80286.

deviceFamilyIs80386(5) deviceFamilyIs80486(6) deviceFamilyIS8087(7)

The processor family is 80386.

The processor family is 80486.

The processor family is 8087.

deviceFamilyIs80287(8) deviceFamilyIs80387(9)

The processor family is 80287.

The processor family is 80387.

deviceFamilyIs80487(10) The processor family is 80487.

deviceFamilyIsPentium(11

)

The processor family is Intel Pentium.

The processor family is Pentium Pro.

deviceFamilyIsPentiumPro

(12) deviceFamilyIsPentium2(1

3) deviceFamilyIsPentiumMMX

(14) deviceFamilyIsCeleron(15

) deviceFamilyIsXeon(16)

The processor family is Pentium II.

The processor family is Pentium MMX.

The processor family is Celeron.

The processor family is Xeon.

Server Administrator Group 217

Table 1001. Processor Device Family (continued) deviceFamilyIsPentium3(1

7) deviceFamilyIsPentium3Xe on(18) deviceFamilyIsPentium3St ep(19) deviceFamilyIsPentiumIta nium (20) deviceFamilyIsIntelXeon(

21) deviceFamilyIsPentium4(2

2) deviceFamilyIsIntelXeonM

P(23) deviceFamilyIsIntelItani um2(24) deviceFamilyIsK5(25) deviceFamilyIsK6(26) deviceFamilyIsK6-2(27) deviceFamilyIsK6-3(28) deviceFamilyIsAMDAthlon(

29) deviceFamilyIsAMD2900(30

) deviceFamilyIsK6-2Plus(3

1) deviceFamilyIsPowerPC(32

) deviceFamilyIsPowerPC601

(33) deviceFamilyIsPowerPC603

(34) deviceFamilyIsPowerPC603

Plus (35) deviceFamilyIsPowerPC604

(36) deviceFamilyIsPowerPC620

(37) deviceFamilyIsPowerPCx70

4(38) deviceFamilyIsPowerPC750

(39) deviceFamilyIsIntelCoreD uo(40) deviceFamilyIsIntelCoreD uoMobi le(41)

The processor family is Pentium III.

The processor family is Pentium III Xeon.

The processor family is Pentium III Speed Step.

The processor family is Itanium.

The processor family is Intel Xeon.

The processor family is Pentium 4.

The processor family is Intel Xeon MP.

The processor family is Intel Itanium 2.

The processor family is K5.

The processor family is K6.

The processor family is K6-2.

The processor family is K6-3.

The processor family is AMD Athlon.

The processor family is AMD2900.

The processor family is K6-2+.

The processor family is Power PC.

The processor family is Power PC 601.

The processor family is Power PC 603.

The processor family is Power PC 603+.

The processor family is Power PC 604.

The processor family is Power PC 620.

The processor family is Power PC x704.

The processor family is Power PC 750.

The processor family is Intel Core Duo.

The processor family is Intel Core Duo mobile.

218 Server Administrator Group

Table 1001. Processor Device Family (continued) deviceFamilyIsIntelCoreS oloMob ile(42) deviceFamilyIsIntelAtom(

43)

The processor family is Intel Core Solo mobile.

The processor family is Intel Atom.

deviceFamilyIsAlpha(48) The processor family is Alpha.

The processor family is Alpha 21064.

deviceFamilyIsAlpha21064

(49) deviceFamilyIsAlpha21066

(50)

The processor family is Alpha 21066.

The processor family is Alpha 21164.

deviceFamilyIsAlpha21164

(51) deviceFamilyIsAlpha21164

PC(52) deviceFamilyIsAlpha21164 a(53) deviceFamilyIsAlpha21264

(54) deviceFamilyIsAlpha21364

(55) deviceFamilyIsAMDTurionI

IUltra DualMobileM(56)

The processor family is Alpha 21164PC.

The processor family is Alpha 21164a.

The processor family is Alpha 21264.

The processor family is Alpha 21364.

deviceFamilyIsAMDTurionI

IDualM obileM(57) deviceFamilyIsAMDAthlonI

IDualM obileM(58) deviceFamilyIsAMDOpteron

6100 (59) deviceFamilyIsAMDOpteron

4100 (60)

The processor family is AMD Turion II Ultra Dual-Core

Mobile M Processor Family.

The processor family is AMD Turion II Dual-Core

Mobile M Processor Family. .

The processor family is AMD Athlon II Dual-Core

Mobile M Processor Family.

The processor family is AMD Opteron 6100 Series

Processor.

deviceFamilyIsAMDOpteron

6200 (61) deviceFamilyIsAMDOpteron

4200 (62) deviceFamilyIsMIPS(64) deviceFamilyIsMIPSR4000(

65)

The processor family is AMD Opteron 4100 Series

Processor.

The processor family is AMD Opteron 6200 Series

Processor.

The processor family is AMD Opteron 4200 Series

Processor.

The processor family is MIPS

The processor family is MIPS R4000.

deviceFamilyIsMIPSR4200(

66) deviceFamilyIsMIPSR4400(

67) deviceFamilyIsMIPSR4600(

68) deviceFamilyIsMIPSR10000

(69)

The processor family is MIPS R4200.

The processor family is MIPS R4400.

The processor family is MIPS R4600.

The processor family is MIPS R10000.

deviceFamilyIsSPARC(80) The processor family is SPARC.

deviceFamilyIsSuperSPARC

(81)

The processor family is SuperSPARC.

Server Administrator Group 219

Table 1001. Processor Device Family (continued) deviceFamilyIsmicroSPARC

II(82) deviceFamilyIsmicroSPARC

IIep (83) deviceFamilyIsUltraSPARC

(84) deviceFamilyIsUltraSPARC

II(85) deviceFamilyIsUltraSPARC

IIi(86)

The processor family is microSPARC II.

The processor family is microSPARC IIep.

The processor family is UltraSPARC.

The processor family is UltraSPARC II.

The processor family is UltraSPARC IIi.

deviceFamilyIsUltraSPARC

III(87) deviceFamilyIsUltraSPARC

IIIi (88)

The processor family is UltraSPARC III.

The processor family is UltraSPARC IIIi.

deviceFamilyIs68040(96) The processor family is 68040 Family.

deviceFamilyIs68xxx(97) The processor family is 68xxx.

deviceFamilyIs68000(98) The processor family is 6800.

deviceFamilyIs68010(99) The processor family is 68010.

deviceFamilyIs68020(100) The processor family is 68020.

deviceFamilyIs68030(101) The processor family is 68030.

The processor family is AMD Zen.

deviceFamilyIsAMDZen(107

) deviceFamilyIsHobbit(112

)

The processor family is Hobbit.

The processor family is Crusoe 5000.

deviceFamilyIsCrusoe5000

(120) deviceFamilyIsCrusoe3000

(121) deviceFamilyIsEfficeon80

00 (122) deviceFamilyIsWeitek(128

) deviceFamilyIsIntelCeler onM(130) deviceFamilyIsAMDAthlon6

4(131)

The processor family is Crusoe 3000.

The processor family is Efficeon 8000.

The processor family is Weitek.

The processor family is Intel Celeron M.

The processor family is AMD Athlon 64.

deviceFamilyIsAMDOpteron

(132) deviceFamilyIsAMDSempron

(133) deviceFamilyIsAMDTurion6

4Mobile(134) deviceFamilyIsDualCoreAM

DOpter on(135) deviceFamilyIsAMDAthlon6

4X2Dual Core(136)

The processor family is AMD Opteron.

The processor family is AMD Sempron.

The processor family is AMD Turion 64 Mobile

Technology.

The processor family is Dual-Core AMD Opteron.

The processor family is AMD Athlon 64 X2 Dual-Core.

220 Server Administrator Group

Table 1001. Processor Device Family (continued) deviceFamilyIsAMDTurion6

4X2Mob ile(137) deviceFamilyIsQuadCoreAM

DOpter on(138) deviceFamilyIsThirdGener ation AMDOpteron(139) deviceFamilyIsAMDPhenomF

XQuadC ore(140) deviceFamilyIsAMDPhenomX

4QuadC ore(141) deviceFamilyIsAMDPhenomX

2DualC ore(142) deviceFamilyIsAMDAthlonX

2DualC ore(143) deviceFamilyIsPA-

RISC(144) deviceFamilyIsPA-

RISC8500(145) deviceFamilyIsPA-

RISC8000(146) deviceFamilyIsPARISC7300

LC( 147) deviceFamilyIsPA-

RISC7200(148) deviceFamilyIsPARISC7100

LC( 149) deviceFamilyIsPA-

RISC7100(150) deviceFamilyIsV30(160) deviceFamilyIsQuadCoreIn telXeon3200(161) deviceFamilyIsDualCoreIn telXeon3000(162) deviceFamilyIsQuadCoreIn telXeon5300(163) deviceFamilyIsDualCoreIn telXeon5100(164) deviceFamilyIsDualCoreIn telXeon5000(165) deviceFamilyIsDualCoreIn telXeonLV(166) deviceFamilyIsDualCoreIn telXeonULV(167) deviceFamilyIsDualCoreIn telXeon7100(168) deviceFamilyIsQuadCoreIn telXeon5400(169)

The processor family is AMD Turion 64 X2 Mobile

Technology.

The processor family is Quad-Core AMD Opteron.

The processor family is thirdgeneration AMD Opteron.

The processor family is AMD Phenom FX Quad-Core.

The processor family is AMD Phenom X4 Quad-Core.

The processor family is AMD Phenom X2 Dual-Core.

The processor family is AMD Athlon X2 Dual-Core.

The processor family is PA-RISC.

The processor family is PA-RISC 8500.

The processor family is PA-RISC 8000.

The processor family is PA-RISC 7300LC.

The processor family is PA-RISC 7200.

The processor family is PA-RISC 7100LC.

The processor family is PA-RISC 7100.

The processor family is V30.

The processor family is Quad-Core Intel Xeon processor 3200 Series.

The processor family is Dual-Core Intel Xeon processor

3000 Series.

The processor family is Quad-Core Intel Xeon processor 5300 Series.

The processor family is Dual-Core Intel Xeon processor

5100 Series.

The processor family is Dual-Core Intel Xeon processor

5000 Series.

The processor family is Dual-Core Intel Xeon processor

LV.

The processor family is Dual-Core Intel Xeon processor

ULV.

The processor family is Dual-Core Intel Xeon processor

7100 Series.

The processor family is Quad-Core Intel Xeon processor 5400 Series.

Server Administrator Group 221

Table 1001. Processor Device Family (continued) deviceFamilyIsQuadCoreIn telXeon(170) deviceFamilyIsDualCoreIn telXeon5200(171) deviceFamilyIsDualCoreIn telXeon7200(172) deviceFamilyIsQuadCoreIn telXeon7300(173) deviceFamilyIsQuadCoreIn telXeon7400(174) deviceFamilyIsMultiCoreI ntelXeon7400(175) deviceFamilyIsM1(176)

The processor family is Multi-Core Intel Xeon processor 7400 Series.

The processor family is M1.

deviceFamilyIsM2(177) deviceFamilyIsIntelPenti um4HT (179)

The processor family is M2.

The processor family is Intel Pentium 4 HT processor.

deviceFamilyIsAS400(180) The processor family is AS400.

deviceFamilyIsAMDAthlonX

P(182)

The processor family is AMD Athlon XP.

The processor family is AMD Athlon MP.

deviceFamilyIsAMDAthlonM

P(183) deviceFamilyIsAMDDuron(1

84)

The processor family is AMD Duron.

The processor family is Intel Pentium M.

deviceFamilyIsIntelPenti umM(185) deviceFamilyIsIntelCeler onD(186) deviceFamilyIsIntelPenti umD(187) deviceFamilyIsIntelPenti umExtreme(188) deviceFamilyIsIntelCoreS olo (189) deviceFamilyIsIntelCore2

(190)

The processor family is Intel Celeron D.

The processor family is Intel Pentium D.

The processor family is Intel Pentium Processor

Extreme Edition.

The processor family is Intel Core Solo processor.

The processor family is Intel Core 2 processor.

deviceFamilyIsIntelCore2

Duo (191) deviceFamilyIsIntelCore2

Solo (192) deviceFamilyIsIntelCore2

Extreme(193) deviceFamilyIsIntelCore2

Quad (194) deviceFamilyIsIntelCore2

Extrem eMobile(195) deviceFamilyIsIntelCore2

DuoMob ile(196)

The processor family is Quad-Core Intel Xeon.

The processor family is Dual-Core Intel Xeon processor

5200 Series.

The processor family is Dual-Core Intel Xeon processor

7200 Series.

The processor family is Quad-Core Intel Xeon processor 7300 Series.

The processor family is Quad-Core Intel Xeon processor 7400 Series.

The processor family is Intel Core 2 Duo processor.

The processor family is Intel Core2 Solo processor.

The processor family is Intel Core2 Extreme processor.

The processor family is Intel Core2 Quad processor.

The processor family is Intel Core2 Extreme mobile processor.

The processor family is Intel Core2 Duo mobile processor.

222 Server Administrator Group

Table 1001. Processor Device Family (continued) deviceFamilyIsIntelCore2

SoloMo bile(197) deviceFamilyIsIntelCorei

7(198) deviceFamilyIsDualCoreIn telCel eron(199) deviceFamilyIsIBM390(200

) deviceFamilyIsG4(201) deviceFamilyIsG5(202) deviceFamilyIsESA390G6(2

03) deviceFamilyIszArchitect ur (204) deviceFamilyIsIntelCorei

5(205)

The processor family is Intel Core2 Solo mobile processor.

The processor family is Intel Core i7 processor.

The processor family is Dual-Core Intel Celeron

Processor.

The processor family is IBM390.

The processor family is G4.

The processor family is G5.

The processor family is ESA/390 G6.

The processor family is z/Architectur base.

The processor family is Intel Core i5 processor.

deviceFamilyIsIntelCorei

3(206) deviceFamilyIsVIAC7-

M(210)

The processor family is Intel Core i3 processor.

The processor family is VIA C7-M.

deviceFamilyIsVIAC7-

D(211)

The processor family is family is VIA C7-D.

deviceFamilyIsVIAC7(212) The processor family is VIA C7.

deviceFamilyIsVIAEden(21

3) deviceFamilyIsMultiCoreI ntelXe on(214) deviceFamilyIsDualCoreIn telXeo n3xxx(215) deviceFamilyIsQuadCoreIn telXeo n3xxx(216)

The processor family is VIA Eden.

The processor family is Multi-Core Intel Xeon processor.

The processor family is Dual-Core Intel Xeon processor

3xxx Series.

The processor family is Quad-Core Intel Xeon processor 3xxx Series.

The processor family is VIA Nano.

deviceFamilyIsVIANano(21

7) deviceFamilyIsDualCoreIn telXeo n5xxx(218) deviceFamilyIsQuadCoreIn telXeo n5xxx(219) deviceFamilyIsDualCoreIn telXeo n7xxx(221) deviceFamilyIsQuadCoreIn telXeo n7xxx(222) deviceFamilyIsMultiCoreI ntelXe on7xxx(223)

The processor family is Dual-Core Intel Xeon processor

5xxx Series.

The processor family is Quad-Core Intel Xeon processor 5xxx Series.

The processor family is Dual-Core Intel Xeon processor

7xxx Series.

The processor family is Quad-Core Intel Xeon processor 7xxx Series.

deviceFamilyIsMultiCoreI ntelXe on3400(224) deviceFamilyIsEmbeddedAM

DOpert onQuadCore(230)

The processor family is Multi-Core Intel Xeon processor 7xxx Series.

The processor family is Multi-Core Intel Xeon processor 3400 Series.

The processor family is Embedded AMD Opteron

Quad-Core.

Server Administrator Group 223

Table 1001. Processor Device Family (continued) deviceFamilyIsAMDPhenomT ripleC ore(231) deviceFamilyIsAMDTurionU ltraDu alCoreMobile(232) deviceFamilyIsAMDTurionD ualCor eMobile(233) deviceFamilyIsAMDAthlonD ualCor e(234) deviceFamilyIsAMDSempron

SI (235) deviceFamilyIsAMDPhenomI

I(236) deviceFamilyIsAMDAthlonI

I(237) deviceFamilyIsSixCoreAMD

Optero n(238) deviceFamilyIsAMDSempron

M(239)

The processor family is AMD Phenom Triple-Core.

The processor family is AMD Turion Ultra Dual-Core mobile processor.

The processor family is AMD Turion Dual-Core mobile processor.

The processor family is AMD Athlon Dual-Core.

The processor family is AMD Sempron SI.

The processor family is AMD Phenom II.

The processor family is AMD Athlon II.

The processor family is Six-Core AMD Opteron.

The processor family is AMD Sempron M.

deviceFamilyIsi860(250) The processor family is i860.

deviceFamilyIsi960(251) The processor family is i960.

deviceFamilyIsAMDOpteron

6200 (261)

The processor family family is AMD Opteron 6200

Series Processor.

Table 1002. Cache Device Type

Variable Name: DellCacheDeviceType

Data Type: Integer

Possible Data Values deviceTypeIsOther(1

) deviceTypeIsUnknown

(2) deviceTypeIsInstruc tion(3)

Meaning of Data Value

System cache type is not one of the following:

System cache type is unknown.

System cache type is instruction.

deviceTypeIsData(4) System cache type is data.

deviceTypeIsUnified

(5)

System cache type is both instruction and data.

Table 1003. Cache Device Level

Variable Name: DellCacheDeviceLevel

Data Type: Integer

Possible Data Values deviceLevelIsOther(

1) deviceLevelIsUnknow n(2)

Meaning of Data Value

Device level is not one of the following:

Device level is unknown.

224 Server Administrator Group

Table 1003. Cache Device Level (continued) deviceLevelIsPrimar y(3) deviceLevelIsSecond ary(4) deviceLevelIsTertia ry(5)

Device level is primary.

Device level is secondary.

Device level is tertiary.

Table 1004. Cache Device Write Policy

Variable Name: DellCacheDeviceWritePolicy

Data Type: Integer

Possible Data Values deviceWritePolicyIs

Other(1) deviceWritePolicyIs

Unknown(2) deviceWritePolicyIs

WriteBack(3) deviceWritePolicyIs

WriteThrough(4) deviceWritePolicyIs

VariesByAddress(5) deviceWritePolicyIs

DeterminedByIO(6)

Meaning of Data Value

Device write policy is not one of the following:

Device write policy is unknown.

Device write policy is write back.

Device write policy is write through.

Device write policy varies by address.

Device write policy is determined by I/O query.

Table 1005. Cache Device Status State

Variable Name: DellCacheDeviceStatusState

Data Type: Integer

Possible Data Values other(1) unknown(2) enabled(3) userDisabled(4) biosDisabled(5)

Meaning of Data Value

Device state is not one of the following:

Device state is unknown.

Device is enabled.

Device is disabled by the user.

Device basic input/output system (BIOS) is disabled.

Table 1006. Cache Device ECC Type

Variable Name: DellPointingDeviceType

Data Type: Integer

Possible Data Values deviceTypeIsOther(1

) deviceTypeIsUnknown

(2) deviceTypeIsAMouse(

3)

Meaning of Data Value

Device type is not one of the following:

Device type is unknown.

Device type is a mouse.

Server Administrator Group 225

Table 1006. Cache Device ECC Type (continued) deviceTypeIsATrackB all(4) deviceTypeIsATrackP oint(5) deviceTypeIsAGlideP oint(6) deviceTypeIsATouchP ad(7)

Device type is a track ball.

Device type is a track point.

Device type is a glide point.

Device type is a touch pad.

Table 1007. Cache Device Associativity

Variable Name: DellCacheDeviceAssociativity

Data Type: Integer

Possible Data Values deviceAssociativity

IsOther(1) deviceAssociativity

IsUnknown(2) deviceAssociativity

IsDirectMapped(3) deviceAssociativity

IsTwoWaySetAssociat ive(4) deviceAssociativity

IsFourWaySetAssocia tive(5) deviceAssociativity

IsFullyAssociative

(6) deviceAssociativity

IsEightWaySetAssoci ative(7) deviceAssociativity

IsSixteenWaySetAsso ciative(8) deviceAssociativity

Is12WaySetAssociati ve(9) deviceAssociativity

Is24WaySetAssociati ve(10) deviceAssociativity

Is32WaySetAssociati ve(11) deviceAssociativity

Is48WaySetAssociati ve(12) deviceAssociativity

Is64WaySetAssociati ve(13)

Meaning of Data Value

Device associativity is not one of the following:

Device associativity is unknown.

Device is direct mapped.

Device is two-way set associative.

Device is four-way set associative.

Device is fully associative.

Device is eight-way set associative.

Device is sixteen-way set associative.

Device is 12-way Set-Associative.

Device is 24-way Set-Associative.

Device is 32-way Set-Associative.

Device is 48-way Set-Associative.

Device is 64-way Set-Associative.

226 Server Administrator Group

Table 1008. Cache Device Location

Variable Name: DellCacheDeviceLocation

Data Type: Integer

Possible Data Values deviceLocationIsOth er(1) deviceLocationIsUnk nown(2) deviceLocationIsInt ernal(3) deviceLocationIsExt ernal(4)

Meaning of Data Value

Device location is not one of the following:

Device location is unknown.

Device location is internal.

Device location is external.

Table 1009. Cache Device Static Random-Access Memory (SRAM) Type

Variable Name: DellCacheDeviceSRAMType

Data Type: Integer

Possible Data Values deviceSRAMTypeIsOth er(1) deviceSRAMTypeIsUnk nown(2) deviceSRAMTypeIsNon

Burst(3) deviceSRAMTypeIsBur st(4) deviceSRAMTypeIsPip eBurst(5) deviceSRAMTypeIsSyn chronous(6) deviceSRAMTypeIsAsy nchronous(7)

Meaning of Data Value

Device SRAM type is not one of the following:

Device SRAM type is unknown.

Device SRAM type is nonburst.

Device SRAM type is burst.

Device SRAM type is pipeburst.

Device SRAM type is synchronous.

Device SRAM type is asynchronous.

Table 1010. Memory Device Type Form Factor

Variable Name: DellMemoryDeviceFormFactor

Data Type: Integer

Possible Data Values deviceFormFactorIsO ther(1) deviceFormFactorIsU nknown(2) deviceFormFactorIsS

IMM(3) deviceFormFactorIsS

IP(4) deviceFormFactorIsA

Chip(5)

Meaning of Data Value

Device form factor is not one of the following:

Device form factor is unknown.

Device form factor is SIMM.

Device form factor is SIP.

Device form factor is a chip.

Server Administrator Group 227

Table 1010. Memory Device Type Form Factor (continued) deviceFormFactorIsD

IP(6) deviceFormFactorIsZ

IP(7) deviceFormFactorIsA

ProprietaryCard(8) deviceFormFactorIsD

IMM(9) deviceFormFactorIsT

SOP(10) deviceFormFactorIsA

RowOfChips(11) deviceFormFactorIsR

IMM(12) deviceFormFactorIsS

ODIMM(13) deviceFormFactorIsS

RIMM(14) deviceFormFactorIsF

BDIMM(15)

Device form factor is DIP.

Device form factor is ZIP.

Device form factor is a proprietary card.

Device form factor is DIMM.

Device form factor is TSOP.

Device form factor is a row of chips.

Device form factor is RIMM.

Device form factor is SODIMM.

Device form factor is SRIMM.

Device form factor is FB-DIMM.

Table 1011. Memory Device Type

Variable Name: DellMemoryDeviceType

Data Type: Integer

Possible Data Values deviceTypeIsOther(1

)

Meaning of Data Value

Device type is not one of the following: deviceTypeIsUnknown

(2)

Device type is unknown.

deviceTypeIsDRAM(3) Device type is DRAM.

deviceTypeIsEDRAM(4

)

Device type is EDRAM.

deviceTypeIsVRAM(5) Device type is VRAM.

deviceTypeIsSRAM(6) Device type is SRAM.

deviceTypeIsRAM(7) Device type is RAM.

deviceTypeIsROM(8) Device type is ROM.

deviceTypeIsFLASH(9

)

Device type is FLASH.

Device type is EEPROM.

deviceTypeIsEEPROM(

10) deviceTypeIsFEPROM(

11)

Device type is FEPROM.

deviceTypeIsEPROM(1

2) deviceTypeIsCDRAM(1

3)

Device type is EPROM.

Device type is CDRAM.

228 Server Administrator Group

Table 1011. Memory Device Type (continued) deviceTypeIs3DRAM(1

4) deviceTypeIsSDRAM(1

5) deviceTypeIsSGRAM(1

6) deviceTypeIsRDRAM(1

7)

Device type is 3DRAM.

Device type is SDRAM.

Device type is SGRAM.

Device type is RDRAM.

deviceTypeIsDDR(18) Device type is DDR.

deviceTypeIsDDR2(19

)

Device type is DDR2.

Device type is DDR2 FB-DIMM.

deviceTypeIsDDR2FBD

IMM(20) deviceTypeIsDDR3(24

) deviceTypeIsFBD2(25

) deviceTypeIsDDR4(26

)

Device type is DDR3.

Device type is FBD2.

Device type is DDR4.

Table 1012. Memory Device Type Details

Variable Name: DellMemoryDeviceTypeDetails

Data Type: Integer

Possible Data Values deviceTypeDetailIsO ther(2) deviceTypeDetailIsU nknown(4) deviceTypeDetailIsF astPaged (8) deviceTypeDetailIsS taticColum n(16) deviceTypeDetailIsP seudoStati c(32) deviceTypeDetailIsR

AMBUS(64) deviceTypeDetailIsS ynchronous (128) deviceTypeDetailIsC

MOS(256) deviceTypeDetailIsE

DO(512) deviceTypeDetailIsW indowDRAM (1024) deviceTypeDetailIsC acheDRAM (2048)

Meaning of Data Value

The detailed device type is not one of the following:

The detailed device type is unknown.

The detailed device type is fast paged.

The detailed device type is static column.

The detailed device type is pseudo-static.

The detailed device type is RAMBUS.

The detailed device type is synchronous.

The detailed device type is CMOS.

The detailed device type is EDO.

The detailed device type is Window DRAM.

The detailed device type is Cache DRAM.

Server Administrator Group 229

Table 1012. Memory Device Type Details (continued) deviceTypeDetailIsN onVolatile (4096) deviceTypeDetailIsR egistered (8192) deviceTypeDetailIsN onRegister ed(16384)

The detailed device type is Non-volatile.

The detailed device type is registered.

The detailed device type is nonregistered.

Table 1013. Generic Device Type

Variable Name: DellGenericDeviceType

Data Type: Integer

Possible Data Values deviceTypeIsOther(1

) deviceTypeIsUnknown

(2) deviceTypeIsAVideoD evice(3) deviceTypeIsASCSICo ntroller(4) deviceTypeIsAnEther netDevice(5) deviceTypeIsTokenRi ngDevice(6) deviceTypeIsASoundD evice(7)

Meaning of Data Value

Device type is not one of the following:

Device type is unknown.

Device type is a video.

Device type is a SCSI controller.

Device type is Ethernet.

Device type is token ring.

Device type is sound.

Table 1014. Memory Device Failure Modes

Variable Name: DellMemoryDeviceFailureModes

Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.

Possible Data Values

(0)

Meaning of Data Value

Memory device has no faults.

eccSingleBitCorrectionWa rningRate(1)

Memory device has exceeded the Correctable Memory

Event warning rate.

eccSingleBitCorrectionFa ilureRate(2)

Memory device has exceeded the Correctable Memory

Event failure rate.

eccMultiBitFault(4) Memory device has encountered an Uncorrectable

Memory Event.

eccSingleBitCorrectionLo ggingDisabled (8)

Correctable Memory Event logging for memory device has been disabled.

deviceDisabledBySpareAct ivation(16)

Memory device is disabled because of spare memory activation.

nvdimmNotReady(32) nvdimmSaveError(64)

NVDIMM is Not Ready

NVDIMM Save Error

230 Server Administrator Group

Table 1014. Memory Device Failure Modes (continued) nvdimmRestoreErrorOrTime out(128)

NVDIMM Restore Error or Restore Timeout nvdimmIllegalConfigurati on(256)

Illegal NVDIMM Configuration nvdimmNotResponding(512) NVDIMM is Not Responding nvdimmArmFailureOrTimeou t(1024)

NVDIMM Arm Failure or Arm Timeout nvdimmsInWriteProtectMod e(2048)

All NVDIMMs in Write-Protect Mode nvmLifetimeExpired(4096) NVM Lifetime Expired nvdimmPersistencyLost(81

92)

NVDIMM Persistency Lost nvdimmPersistencyRestore d(16384)

NVDIMM Persistency Restored nvmLifetimeLessThanFiveP ercent(32768)

NVM Lifetime less than Five Percent

Table 1015. Device Memory Technology

Variable Name: DellMemoryDeviceMemoryTechnology

Data Type: Integer

Possible Data Values other(1) unknown(2) dram(3) nvdimm-n(4) nvdimm-f(5) nvdimm-p(6) intelpersistentmemo ry(7)

Meaning of Data Value

Technology is Other.

Technology is Unknown.

Technology is DRAM.

Technology is NVDIMM-N.

Technology is NVDIMM-F.

Technology is NVDIMM-P.

Technology is Intel Persistent Memory.

Table 1016. Network Device Connection Status

Variable Name: DellNetworkDeviceConnectionStatus

Data Type: Integer

Possible Data Values unknown(0) connected(1) disconnected(2) driverBad(3) driverDisabled(4) hardwareInitalizing

(10) hardwareResetting(1

1)

Meaning of Data Value

Unable to determine connection status.

Media reports that device is connected.

Media reports that device is disconnected.

Driver cannot be opened to determine status.

Driver is disabled.

Hardware is initializing.

Hardware is resetting.

Server Administrator Group 231

Table 1016. Network Device Connection Status (continued) hardwareClosing(12) Hardware is closing down.

hardwareNotReady(13

)

Hardware is not ready.

Table 1017. Network Device Teaming Flags

Variable Name: DellNetworkDeviceTeamingFlags

Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.

Possible Data Values undefined(0) noTeam(1) teamingEnabled(2) adapterFaultToleran ceMode(4) loadBalancingMode(8

)

Meaning of Data Value

Teaming flags are undefined.

Device is not part of any team.

Teaming is enabled.

Adapter fault tolerance teaming mode.

Load balancing teaming mode.

Table 1018. Network Device TOE Capability Flags

Variable Name: DellNetworkDeviceTOECapabilityFlags

Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.

Possible Data Values none(0) unknown(1) available(2) notAvailable(4) cannotBeDetermined(

8) driverNotResponding

(16)

Meaning of Data Value

Querying for TOE capability is not supported.

Querying for TOE capability is supported but query returned an error.

Device has TOE capability.

Device does not have TOE capability.

Querying for TOE capability is supported but an error prevented querying.

Querying for TOE capability is supported but driver did not respond to query.

Table 1019. Network Device RDMA Capability Flags

Variable Name: DellNetworkDeviceRDMACapabilityFlags

Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.

Possible Data Values none(0) unknown(1) available(2) notAvailable(4)

Meaning of Data Value

Querying for RDMA capability is not supported.

Querying for RDMA capability is supported but query returned an error.

Device has RDMA capability.

Device does not have RDMA capability.

232 Server Administrator Group

Table 1019. Network Device RDMA Capability Flags (continued) cannotBeDetermined(

8) driverNotResponding

(16)

Querying for RDMA capability is supported but an error prevented querying.

Querying for RDMA capability is supported but driver did not respond to query.

Table 1020. Network Device iSCSI Capability Flags

Variable Name: DellNetworkDeviceiSCSICapabilityFlags

Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.

Possible Data Values none(0) unknown(1) available(2) notAvailable(4) cannotBeDetermined(

8) driverNotResponding

(16)

Meaning of Data Value

Querying for iSCSI capability is not supported.

Querying for iSCSI capability is supported but query returned an error.

Device has iSCSI capability.

Device does not have iSCSI capability.

Querying for iSCSI capability is supported but an error prevented querying.

Querying for iSCSI capability is supported but driver did not respond to query.

Table 1021. Network Device Capabilities

Variable Name: DellNetworkDeviceCapabilities

Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.

Possible Data Values notSupported(0) supported(1) toe(2) iscsiOffload(4) fcoeOffload(8)

Meaning of Data Value

Device does not support reporting capabilities through this attribute.

Device supports reporting capabilities through this attribute.

Device has TOE capability.

Device has iSCSI Offload capability.

Device has FCoE Offload capability.

Table 1022. Network Device NParEPEnabled

Variable Name: DellNetworkDeviceNParEPEnabled

Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.

Possible Data Values

Disabled(1) enabled(2) unknown(3)

Meaning of Data Value

Device does not support NParEP mode.

Device supports NParEP mode.

Device does not recognize NParEP mode.

Server Administrator Group 233

Table 1023. Managed System Services Device Type

Variable Name: DellManagedSystemServicesDeviceType

Data Type: Integer

Possible Data Values baseDevice(0) optionalDevice(1)

Meaning of Data Value

Device type is base device.

Device type is optional device.

Table 1024. SD Card Device Type

Variable Name: DellSDCardDeviceType

Data Type: Integer

Possible Data Values other(1) unknown(2) hypervisor(3) vFlash(4)

Meaning of Data Value

Device type is other.

Device type is unknown.

Device type is Hypervisor.

Device type is Virtual Flash (vFlash.)

Table 1025. SD Card Device Config Capabilities

Variable Name: DellSDCardDeviceConfigCapabilities

Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.

Possible Data Values none(0) sdCapable(1) vFlashCapable(2)

Meaning of Data Value

SD card device has none of the following capabilities.

SD media can be enabled.

Virtual Flash (vFlash) can be enabled.

Table 1026. SD Card Device Config Settings

Variable Name: DellSDCardDeviceConfigSettings

Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.

Possible Data Values none(0) sdEnabled(1) vFlashEnabled(2)

Meaning of Data Value

SD card device has none of the following settings.

SD media is enabled.

Virtual Flash (vFlash) is enabled.

Table 1027. SD Card Device Card State

Variable Name: DellSDCardDeviceCardState

Data Type: Integer

Possible Data Values none(0) present(1) ipmiReady(2)

Meaning of Data Value

SD card state is none of the following states.

Device is present.

Device is IPMI ready.

234 Server Administrator Group

Table 1027. SD Card Device Card State (continued) fullReady(4) offline(8) failed(16) active(32) bootable(64) writeProtect(128) standby(256)

Device is full ready.

Device is offline.

Device is failed.

Device is active.

Device is bootable.

Device is write-protected.

Device is in standby mode.

Table 1028. SD Card Device Card Licensed

Variable Name: DellSDCardDeviceCardLicensed

Data Type: Integer

Possible Data Values unlicensed(0) licensed(1) ipmiReady(2) fullReady(4) offline(8) failed(16) active(32) bootable(64) writeProtect(128) standby(256)

Meaning of Data Value

SD card is not licensed by system vendor.

SD card is licensed by system vendor.

Device is IPMI ready.

Device is full ready.

Device is offline.

Device is failed.

Device is active.

Device is bootable.

Device is write-protected.

Device is in standby mode.

Slot Group

The Slot Group provides information about the types of slots that your system supports. This management information base

(MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots.

System Slot Group Table

The System Slot Group defines objects in the System Slot MIB table.

The following object sets up the System Slot Table:

Table 1029. System Slot Table

Name

Object ID

Description

Syntax

Access systemSlotTable

1.3.6.1.4.1.674.10892.1.1200.10

Defines the System Slot Table.

IntegerSystemStateTableEntry

Not accessible

Server Administrator Group 235

Table 1030. System Slot Table Entry

Name

Object ID

Description

Syntax

Access

Index systemSlotTableEntry

1.3.6.1.4.1.674.10892.1.1200.10.1

Defines the System Slot Table entry.

IntegerSystemSlotTableEntry

Not accessible systemSlotchassisIndex

, systemSlotIndex

Table 1031. System Slot Chassis Index

Name

Object ID

Description

Syntax

Access systemSlotchassisIndex

1.3.6.1.4.1.674.10892.1.1200.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1032. System Slot Index

Name

Object ID

Description

Syntax

Access systemSlotIndex

1.3.6.1.4.1.674.10892.1.1200.10.1.2

Defines the index (one-based) of the system slot in this chassis.

DellObjectRange

Read-only

Table 1033. System Slot State Capabilities Unique

Name

Object ID

Description

Syntax

Access systemSlotStateCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1200.10.1.3

Defines the capabilities of the system slot.

DellSystemSlotStateCapabilities ( System Slot State Capabilities )

Read-only

Table 1034. System Slot State Settings Unique

Name

Object ID

Description

Syntax

Access systemSlotStateSettingsUnique

1.3.6.1.4.1.674.10892.1.1200.10.1.4

Defines the state of the system slot.

DellSystemSlotStateSettings (

System Slot State Settings

)

Read-only

Table 1035. System Slot Status

Name

Object ID systemSlotStatus

1.3.6.1.4.1.674.10892.1.1200.10.1.5

236 Server Administrator Group

Table 1035. System Slot Status (continued)

Description

Syntax

Access

Defines the status of the system slot.

DellStatus

Read-only

Table 1036. System Slot Current Usage

Name

Object ID

Description

Syntax

Access systemSlotCurrentUsage

1.3.6.1.4.1.674.10892.1.1200.10.1.6

Defines the current usage of the system slot.

DellStatus

Read-only

Table 1037. System Slot Type

Name

Object ID

Description

Syntax

Access systemSlotType

1.3.6.1.4.1.674.10892.1.1200.10.1.7

Defines the type of the system slot.

DellSystemSlotType (

System Slot Type

)

Read-only

Table 1038. System Slot External Slot Name

Name

Object ID

Description

Syntax

Access systemSlotSlotExternalSlotName

1.3.6.1.4.1.674.10892.1.1200.10.1.8

Defines the external connector name of the system slot.

DellString

Read-only

Table 1039. System Slot Length

Name

Object ID

Description

Syntax

Access systemSlotLength

1.3.6.1.4.1.674.10892.1.1200.10.1.9

Defines the length of the system slot.

DellSystemSlotLength (

System Slot Length )

Read-only

Table 1040. System Slot Slot ID

Name

Object ID

Description

Syntax

Access systemSlotSlotID

1.3.6.1.4.1.674.10892.1.1200.10.1.10

Defines the slot identification number of the system slot. A zero (0) indicates that the slot is embedded on the motherboard.

DellUnsigned32BitRange

Read-only

Table 1041. System Slot Category

Name systemSlotCategory

Server Administrator Group 237

Table 1041. System Slot Category (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1200.10.1.11

Defines the system slot category.

DellUnsigned32BitRange

Read-only

Table 1042. System Slot Hot-Plug Bus Width

Name

Object ID

Description

Syntax

Access systemSlotHotPlugBusWidth

1.3.6.1.4.1.674.10892.1.1200.10.1.12

Defines the bus width of the hot-plug system slot.

DellSystemSlotHotPlugBusWidth (

Hot-Plug Bus Width )

Read-only

Table 1043. System Slot Hot-Plug Slot Speed

Name

Object ID

Description

Syntax

Access systemSlotHotPlugSlotSpeed

1.3.6.1.4.1.674.10892.1.1200.10.1.13

Defines the slot speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown.

DellUnsigned32BitRange

Read-only

Table 1044. System Slot Hot-Plug Adapter Speed

Name

Object ID

Description

Syntax

Access systemSlotHotPlugAdapterSpeed

1.3.6.1.4.1.674.10892.1.1200.10.1.14

Defines the adapter speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown.

DellUnsigned32BitRange

Read-only

System Slot Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 1045. System Slot State Capabilities

Variable Name : DellSystemSlotStateCapabilities

Data Type : Integer

Possible Data Values systemSlotHotPlugIsUnknown (1) systemSlotHotPlugIsHotPlug gableCapable(2) systemSlotHotPlugCanBePower edOn(4) systemSlotHotPlugCanSignal Attention(8)

Meaning of Data Value

The system slot’s capabilities are unknown.

The system slot supports hot-plug.

The system slot power (and corresponding light-emitting diode [LED]) can be powered on.

The system slot attention state (and corresponding LED) can be set.

238 Server Administrator Group

Table 1045. System Slot State Capabilities (continued) systemSlotHotPlugCanSignal PowerFault(16) systemSlotHotPlugCanSignal

AdapterPresent(32) systemSlotHotPlugCanSignal

PowerButtonPressed(64) canSupportAllHotPlugCapabi lities(126) systemSlotHotPlugIsUnknown (1) systemSlotCanProvide5Volts (128) systemSlotCanProvide3Point 3Volts(256) systemSlotCanSignalIfShared (512) systemSlotCanSupportCard16 (1024) systemSlotCanSupportCardBus (2048) systemSlotCanSupportZoomVid eo(4096) systemSlotCanSupportModem RingResume(8192) systemSlotCanSupportPMESig nal(16384) canSupportAllSlotCapabilit ies(32640)

Power on fault (and corresponding LED) can be detected due to a short or overcurrent.

Adapter (card) present in slot (may not be powered) can be detected.

The system slot power button can be pressed to signal a toggle of the power state.

The system slot can support all hot-plug capabilities.

The system slot’s capabilities are unknown.

The system slot can provide a 5-volt (V) supply.

The system slot can provide a 3.3-V supply.

The system slot’s opening, if shared with another slot, can be detected.

The system slot can support PC Card-16.

The system slot can support CardBus.

The system slot can support Zoom Video.

The system slot can support modem ring resume.

The system slot can support Power Management Enable

(PME#) signal.

The system slot can support all slot capabilities.

Table 1046. System Slot State Settings

Variable Name : DellSystemSlotStateSettings

Data Type : Integer

Possible Data Values systemSlotHotPlugIsUnknown(1) systemSlotHotPlugIsHotPluggable(2) systemSlotHotPlugIsPoweredOn(4) systemSlotHotPlugIsAtAttention(8) systemSlotHotPlugIsHotPluggable(2) systemSlotHotPlugIsPoweredOn(4) systemSlotHotPlugIsAtAttention(8) systemSlotHotPlugHasPowerFaulted (16) systemSlotHotPlugAdapterIsPresent (32) systemSlotHotPlugAdapterPresentAnd

PoweredOn(36) systemSlotHotPlugPowerButtonPressed (64)

Meaning of Data Value

The system slot’s capabilities are unknown.

The system slot supports hot-plug.

The system slot power (and corresponding LED) can be powered on.

The system slot attention state (and corresponding LED) can be set.

The system slot supports hot-plug.

The system slot power (and corresponding LED) is on.

The system slot attention state (and corresponding LED) is on.

Power on fault (and corresponding LED) was detected due to a short or overcurrent.

Adapter (card) present in slot (may not be powered).

Adapter (card) present in slot and powered.

systemSlotProvides5Volts(128) systemSlotProvides3Point3Volts(256)

The system slot power button pressed to signal a toggle of the power state.

The system slot provides a 5-V supply.

The system slot provides a 3.3-V supply.

Server Administrator Group 239

Table 1046. System Slot State Settings (continued) systemSlotIsShared(512) systemSlotSupportsCard16(1024) systemSlotSupportsCardBus(2048) systemSlotSupportsZoomVideo(4096) systemSlotSupportsModemRingResume (8192)

The slot’s opening is shared with another slot.

The system slot supports PC Card-16.

The system slot supports CardBus.

The system slot supports zoom video.

The system slot supports modem ring resume.

systemSlotSupportsPMESignal(16384) The system slot supports power management enable (PME#) signal.

The system slot supports power management enable.

supportsPMEand3P3Vand5VandHotPlugg able(16770) supportsPMEand3P3Vand5VhasAdapterO n(16804) The system slot supports power management event (PME), supplies 3.3 V, and supplies 5 V. The adapter is on.

supportsPMEand3P3Vand5VhasAdapter

OnandisHotPluggable(16806) supportsPMEand3P3VIsSharedand5Vhas

AdapterOnandisHotPluggable(17316)

The system slot supports PME, supplies 3.3 V, and supplies 5

V. The adapter is on and the system slot is hot pluggable.

The system slot supports PME, supplies 3.3 V, supplies 5 V, and shares a slot opening. The adapter is on and the system slot is hot pluggable.

Table 1047. System Slot Type

Variable Name : DellSystemSlotType

Data Type : Integer

Possible Data Values systemSlotIsOther(1) systemSlotIsUnknown(2) systemSlotIsISA(3) systemSlotIsMCA(4) systemSlotIsEISA(5) systemSlotIsPCI(6) systemSlotIsPCMCIA(7) systemSlotIsVLVESA(8) systemSlotIsProprietary(9) systemSlotIsProcessorCard(10) systemSlotIsProprietaryMemory(11) systemSlotIsIORiserCard(12) systemSlotIsNuBUS(13) systemSlotIsPCI66MHz(14) systemSlotIsAGP(15) systemSlotIsAGP2X(16) systemSlotIsAGP4X(17) systemSlotIsPCIX(18)

Meaning of Data Value

The system slot type is not one of following:

The system slot type is unknown.

The system slot is Industry Standard Architecture (ISA).

The system slot is Micro Channel Architecture (MCA).

The system slot is Extended Industry Standard Architecture

(EISA).

The system slot is Peripheral Component Interconnect (PCI).

The system slot is compliant with the Personal Computer

Memory Card International Association (PCMCIA) standards

The system slot is Very Low Voltage Enterprise System

Architecture (VLVESA).

The system slot is proprietary.

The system slot is a processor card.

The system slot is proprietary memory.

The system slot is an I/O riser card.

The system slot is a NuBus.

The system slot is a PCI66MHz.

The system slot is an Advanced Graphics Port (AGP).

The system slot is an AGP 2x card.

The system slot is an AGP 4x card.

The system slot type is PCI-X.

240 Server Administrator Group

Table 1047. System Slot Type (continued) systemSlotIsAGP8X(19) systemSlotIsM2Socket1DP(20) systemSlotIsM2Socket1SD(21) systemSlotIsM2Socket2(22) systemSlotIsM2Socket3(23) systemSlotIsMXMT1(24) systemSlotIsMXMT2(25) systemSlotIsMXMT3SC(26) systemSlotIsMXMT3HEC(27) systemSlotIsMXMT4(28) systemSlotIsMXM3TA(29) systemSlotIsMXM3TB(30) systemSlotIsPCIEGEN2SFF8639(31) systemSlotIsPCIEGEN3SFF8639(32) systemSlotIsPCIEMINI52PWBK(33) systemSlotIsPCIEMINI52PWOBK(34) systemSlotIsPCIEMINI76P(35) systemSlotIsPC98C20(160) systemSlotIsPC98C24(161) systemSlotIsPC98E(162) systemSlotIsPC98LocalBus(163) systemSlotIsPC98Card(164) systemSlotIsPCIExpress(165) systemSlotIsPCIExpressX1(166) systemSlotIsPCIExpressX2(167) systemSlotIsPCIExpressX4(168) systemSlotIsPCIExpressX8(169) systemSlotIsPCIExpressX16(170) systemSlotIsPCIExpressGen2(171) systemSlotIsPCIExpressGen2X1(172) systemSlotIsPCIExpressGen2X2(173) systemSlotIsPCIExpressGen2X4(174) systemSlotIsPCIExpressGen2X8(175) systemSlotIsPCIExpressGen2X16(176) systemSlotIsPCIExpressGen3(177) systemSlotIsPCIExpressGen3X1(178) systemSlotIsPCIExpressGen3X2(179)

The system slot type is an AGP 8X card.

The system slot type is M.2 Socket 1-DP (Mechanical Key A).

The system slot type is M.2 Socket 1-SD (Mechanical Key E).

The system slot type is M.2 Socket 2 (Mechanical Key B).

The system slot type is M.2 Socket 3 (Mechanical Key M).

The system slot is MXM Type I.

The system slot is MXM Type II.

The system slot is MXM Type III (standard connector).

The system slot is MXM Type III (HE connector).

The system slot is MXM Type IV.

The system slot is MXM 3.0 Type A.

The system slot is MXM 3.0 Type B.

The system slot is PCI Express Gen 2 SFF-8639.

The system slot is PCI Express Gen 3 SFF-8639.

The system slot is PCI Express Mini 52-pin with bottom-side keep-outs.

The system slot is PCI Express Mini 52-pin without bottomside keep-outs.

The system slot is PCI Express Mini 76-pin.

The system slot is PC-98/C20.

The system slot is PC-98/C24.

The system slot type is PC-98/E.

The system slot type is PC-98 local bus.

The system slot type is PC-98.

The system slot type is PCI Express.

The system slot type is a PCI Express x1.

The system slot type is a PCI Express x2.

The system slot type is a PCI Express x4.

The system slot type is a PCI Express x8.

The system slot type is a PCI Express x16.

The system slot type is PCI Express Gen 2.

The system slot type is PCI Express Gen 2 x1.

The system slot type is PCI Express Gen 2 x2

The system slot type is PCI Express Gen 2 x4.

The system slot type is PCI Express Gen 2 x8.

The system slot type is PCI Express Gen 2 x16.

The system slot type is PCI Express Gen 3.

The system slot type is PCI Express Gen 3 x1.

The system slot type is PCI Express Gen 3 x2.

Server Administrator Group 241

Table 1047. System Slot Type (continued) systemSlotIsPCIExpressGen3X4(180) systemSlotIsPCIExpressGen3X8(181) systemSlotIsPCIExpressGen3X16(182) systemSlotIsPCIExpressGen4(184) systemSlotIsPCIExpressGen4X1(185) systemSlotIsPCIExpressGen4X2(186) systemSlotIsPCIExpressGen4X4(187) systemSlotIsPCIExpressGen4X8(188) systemSlotIsPCIExpressGen4X16(189)

Table 1048. System Slot Usage

Variable Name : DellSystemSlotUsage

Data Type : Integer

Possible Data Values systemSlotUsageIsOther(1) systemSlotUsageIsUnknown(2) systemSlotUsageIsAvailable(3) systemSlotUsageIsInUse(4) systemSlotUsageIsUnAvailable(5)

Table 1049. System Slot Length

Variable Name : DellSystemSlotLength

Data Type : Integer

Possible Data Values systemSlotLengthIsOther(1) systemSlotLengthIsUnknown(2) systemSlotLengthIsShort(3) systemSlotLengthIsLong(4) systemSlotLengthIs25dff(5) systemSlotLengthIs35dff(6)

Table 1050. System Slot Category

Variable Name : DellSystemSlotCategory

Data Type : Integer

Possible Data Values systemSlotCategoryIsOther(1) systemSlotCategoryIsUnknown(2) systemSlotCategoryIsBusConnector(3) systemSlotCategoryIsPCMCIA(4) systemSlotCategoryIsMotherboard(5)

242 Server Administrator Group

The system slot type is PCI Express Gen 3 x4.

The system slot type is PCI Express Gen 3 x8.

The system slot type is PCI Express Gen 3 x16.

The system slot type is PCI Express Gen 4.

The system slot type is PCI Express Gen 4 x1.

The system slot type is PCI Express Gen 4 x2.

The system slot type is PCI Express Gen 4 x4.

The system slot type is PCI Express Gen 4 x8.

The system slot type is PCI Express Gen 4 x16.

Meaning of Data Value

The system slot usage is not one of following:

The system slot usage is unknown.

The system slot is available.

The system slot is in use.

The system slot is unavailable.

Meaning of Data Value

The system slot length is not one of following:

The system slot length is unknown.

The system slot length is short.

The system slot length is long.

The system slot length is 2.5" drive form factor.

The system slot length is 3.5" drive form factor.

Meaning of Data Value

The system slot category is not one of following:

The system slot category is unknown.

The system slot is a bus connector.

The system slot category is PCMCIA.

The system slot is a motherboard.

Table 1051. Hot-Plug Bus Width

Variable Name : DellSystemSlotHotPlugBusWidth

Data Type : Integer

Possible Data Values busWidthIsOther(1) busWidthIsUnknown(2) busWidthIs8bits(3) busWidthIs16bits(4) busWidthIs32bits(5) busWidthIs64bits(6) busWidthIs128bits(7) busWidthIs1xOrx1(8) busWidthIs2xOrx2(9) busWidthIs4xOrx4(10) busWidthIs8xOrx8(11) busWidthIs12xOrx12(12) busWidthIs16xOrx16(13) busWidthIs32xOrx32(14)

Meaning of Data Value

The system slot bus width is not one of following:

The system slot bus width is unknown.

The system slot bus width is 8 bits.

The system slot bus width is 16 bits.

The system slot bus width is 32 bits.

The system slot bus width is 64 bits.

The system slot bus width is 128 bits.

The system slot bus width is 1x or x1.

The system slot bus width is 2x or x2.

The system slot bus width is 4x or x4.

The system slot bus width is 8x or x8.

The system slot bus width is 12x or x12.

The system slot bus width is 16x or x16.

The system slot bus width is 32x or x32.

NOTE: System slot bus width of type n bits are for parallel buses such as PCI.

NOTE: System slot bus width of type nx or xn are for serial buses such as PCI Express.

Memory Group

The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory.

Physical Memory Tables

The following management information base (MIB) tables define the objects in the Memory Group:

Physical Memory Array Table

Physical Memory Array Mapped Table

Physical Memory Configuration Table

Physical Memory Logging Table

Redundant Memory Unit Table

Physical Memory Card Table

Physical Memory Array Table

The physical memory array is the entire physical memory of a system. The example that follows shows variable values for a system that has one 128-megabyte (MB) dual in-line memory module (DIMM):

● physicalMemoryArrayMaximumSize = 2,097,152 kilobytes (KB) or 2 gigabytes (GB)

● physicalMemoryArrayTotalNumberSockets = 4 (the example system has four DIMM slots on the motherboard)

● physicalMemoryArrayInUseNumberSockets = 1 (there is only one DIMM installed)

The Rank of the DIMM are :

Server Administrator Group 243

● 0 — Unknown

● 1 — Single

● 2 — Dual

● 4 — Quad

● 8 — Octal

● 16 — Hexa

The following object sets up the Physical Memory Array Table:

Table 1052. Physical Memory Array Table

Name physicalMemoryArrayTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1300.10

Defines the Physical Memory Array Table.

PhysicalMemoryArrayTableEntry

Not accessible

Table 1053. Physical Memory Array Table Entry

Name

Object ID

Description

Syntax

Access

Index physicalMemoryArrayTableEntry

1.3.6.1.4.1.674.10892.1.1300.10.1

Defines the Physical Memory Array Table entry.

PhysicalMemoryArrayTableEntry

Not accessible physicalMemoryArraychassisIndex

, physicalMemoryArrayIndex

Table 1054. Physical Memory Array Chassis Index

Name physicalMemoryArraychassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1300.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1055. Physical Memory Array Index

Name

Object ID

Description

Syntax

Access physicalMemoryArrayIndex

1.3.6.1.4.1.674.10892.1.1300.10.1.2

Defines the index (one-based) of the physical memory array in this chassis.

DellObjectRange

Read-only

Table 1056. Physical Memory Array State Capabilities

Name

Object ID

Description physicalMemoryArrayStateCapabilities

1.3.6.1.4.1.674.10892.1.1300.10.1.3

Defines the capabilities of the physical memory array.

244 Server Administrator Group

Table 1056. Physical Memory Array State Capabilities (continued)

Syntax

Access

DellStateCapabilities

Read-only

Table 1057. Physical Memory Array State Settings

Name

Object ID

Description

Syntax

Access physicalMemoryArrayStateSettings

1.3.6.1.4.1.674.10892.1.1300.10.1.4

Defines the state of the physical memory array.

DellStateSettings

Read-only

Table 1058. Physical Memory Array Status

Name

Object ID

Description

Syntax

Access physicalMemoryArrayStatus

1.3.6.1.4.1.674.10892.1.1300.10.1.5

Defines the status of the physical memory array.

DellStatus

Read-only

Table 1059. Physical Memory Array Use

Name

Object ID

Description

Syntax

Access physicalMemoryArrayUse

1.3.6.1.4.1.674.10892.1.1300.10.1.6

Defines the use of the physical memory array.

DellPhysicalMemoryArrayUse (See

Physical Memory Array ECC Type Definitions )

Read-only

Table 1060. Physical Memory Array Error Checking and Correcting (ECC) Type

Name

Object ID

Description

Syntax

Access physicalMemoryArrayECCType

1.3.6.1.4.1.674.10892.1.1300.10.1.7

Defines the ECC type used by the physical memory array.

DellPhysicalMemoryArrayECCType (See

Physical Memory Array ECC Type Definitions )

Read-only

Table 1061. Physical Memory Array Location

Name physicalMemoryArrayLocation

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1300.10.1.8

Defines the location of the physical memory array.

DellPhysicalMemoryArrayLocation (See

Physical Memory Array Location )

Read-only

Table 1062. Physical Memory Array Maximum Size

NOTE: physicalMemoryArrayMaximumSize is no longer in use. This attribute is deprecated and replaced by physicalMemoryArrayExtendedMaximumSize .

Name physicalMemoryArrayMaximumSize

Server Administrator Group 245

Table 1062. Physical Memory Array Maximum Size (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1300.10.1.9

Defines the size in KB of the physical memory array.

DellUnsigned32BitRange

Read-only

Table 1063. Physical Memory Array Total Number Sockets

Name

Object ID

Description

Syntax

Access physicalMemoryArrayTotalNumberSockets

1.3.6.1.4.1.674.10892.1.1300.10.1.10

Defines the total number of memory sockets available for the physical memory array.

DellUnsigned32BitRange

Read-only

Table 1064. Physical Memory Array In Use Number Sockets

Name

Object ID

Description

Syntax

Access physicalMemoryArrayInUseNumberSockets

1.3.6.1.4.1.674.10892.1.1300.10.1.11

Defines the total number of memory sockets in use by the physical memory array.

DellUnsigned32BitRange

Read-only

Table 1065. Physical Memory Array ECC Error Nonrecoverable Threshold

Name

Object ID

Description

Syntax

Access physicalMemoryArrayECCErrorNonRecoverbeThreshold

1.3.6.1.4.1.674.10892.1.1300.10.1.12

Defines the value of the physical memory array Error Checking and Correction (ECC) error nonrecoverable threshold.

DellSigned32BitRange

Read-only

Table 1066. Physical Memory Array ECC Error Critical Threshold

Name

Object ID

Description

Syntax

Access physicalMemoryArrayECCErrorCriticalThreshold

1.3.6.1.4.1.674.10892.1.1300.10.1.13

Defines the value of the physical memory array ECC error critical threshold.

DellSigned32BitRange

Read-only

Table 1067. Physical Memory Array ECC Error Noncritical Threshold

Name

Object ID

Description

Syntax

Access physicalMemoryArrayECCErrorNonCriticalThreshold

1.3.6.1.4.1.674.10892.1.1300.10.1.14

Defines the value of the physical memory array ECC error noncritical threshold.

DellSigned32BitRange

Read-only

246 Server Administrator Group

Table 1068. Physical Memory Array Redundant Memory Unit Index Reference

Name

Object ID

Description

Syntax

Access physicalMemoryArrayRedundantMemoryUnitIndexReference

1.3.6.1.4.1.674.10892.1.1300.10.1.15

Defines the index to the associated Redundant Memory Unit in this chassis.

DellObjectRange

Read-only

Table 1069. Physical Memory Array Extended Maximum Size

NOTE: This attribute replaces the physicalMemoryArrayMaximumSize .

Name

Object ID

Description

Syntax

Access physicalMemoryArrayExtendedMaximumSize

1.3.6.1.4.1.674.10892.1.1300.10.1.16

This attribute defines the maximum size in Bytes of the physical memory array.

DellUnsigned64BitRange

Read-only

Physical Memory Array Mapped Table

The physical memory array is divided into memory array mapped addresses.

The following object sets up the Physical Memory Array Mapped Table:

Table 1070. Physical Memory Array Mapped Table

Name

Object ID

Description

Syntax

Access physicalMemoryArrayMappedTable

1.3.6.1.4.1.674.10892.1.1300.20

Defines the Physical Memory Array Mapped Table.

PhysicalMemoryArrayMappedTableEntry

Not accessible

Table 1071. Physical Memory Array Mapped Table Entry

Name

Object ID

Description

Syntax

Access

Index

PhysicalMemoryArrayMappedTableEntry

1.3.6.1.4.1.674.10892.1.1300.20.1

Defines the Physical Memory Array Mapped Table entry.

PhysicalMemoryArrayMappedTableEntry

Not accessible physicalMemoryArrayMappedchassisIndex

, physicalMemoryArrayMappedIndex

Table 1072. Physical Memory Array Mapped Chassis Index

Name

Object ID

Description physicalMemoryArrayMappedchassisIndex

1.3.6.1.4.1.674.10892.1.1300.20.1.1

Defines the index (one-based) of this chassis.

Server Administrator Group 247

Table 1072. Physical Memory Array Mapped Chassis Index (continued)

Syntax

Access

DellObjectRange

Read-only

Table 1073. Physical Memory Array Mapped Index

Name

Object ID

Description

Syntax

Access physicalMemoryArrayMappedIndex

1.3.6.1.4.1.674.10892.1.1300.20.1.2

Defines the index (one-based) of the memory array mapped address in this chassis.

DellObjectRange

Read-only

Table 1074. Physical Memory Array Mapped State Capabilities

Name

Object ID

Description

Syntax

Access physicalMemoryArrayMappedStateCapabilities

1.3.6.1.4.1.674.10892.1.1300.20.1.3

Defines the capabilities of the memory array mapped address.

DellStateCapabilities

Read-only

Table 1075. Physical Memory Array Mapped State Settings

Name

Object ID

Description

Syntax

Access physicalMemoryArrayMappedStateSettings

1.3.6.1.4.1.674.10892.1.1300.20.1.4

Defines the state of the memory array mapped address.

DellStateSettings

Read-only

Table 1076. Physical Memory Array Mapped Status

Name

Object ID

Description

Syntax

Access physicalMemoryArrayMappedStatus

1.3.6.1.4.1.674.10892.1.1300.20.1.5

Defines the status of the memory array mapped address.

DellStatus

Read-only

Table 1077. Physical Memory Array Index Reference

Name physicalMemoryArrayIndexReference

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1300.20.1.6

Defines the index to the associated physical memory array in this chassis.

DellObjectRange

Read-only

Table 1078. Physical Memory Array Mapped Starting Address

Name

Object ID

Description physicalMemoryArrayMappedStartingAddress

1.3.6.1.4.1.674.10892.1.1300.20.1.7

Defines the physical starting address in KB of the memory array mapped address.

248 Server Administrator Group

Table 1078. Physical Memory Array Mapped Starting Address (continued)

Syntax

Access

DellUnsigned64BitRange

Read-only

Table 1079. Physical Memory Array Mapped Ending Address

Name

Object ID

Description

Syntax

Access physicalMemoryArrayMappedEndingAddress

1.3.6.1.4.1.674.10892.1.1300.20.1.8

Defines the physical ending address in KB of the memory array mapped address.

DellUnsigned64BitRange

Read-only

Table 1080. Physical Memory Array Mapped Partition Width

Name

Object ID

Description

Syntax

Access physicalMemoryArrayMappedPartitionWidth

1.3.6.1.4.1.674.10892.1.1300.20.1.9

Defines the number of memory devices that form a single row in the memory array mapped address. A zero (0) indicates that the number is unknown.

DellUnsigned32BitRange

Read-only

Physical Memory Configuration Table

This table defines how the physical memory of a system chassis is set up, for example, which redundant memory types are supported and whether redundant memory is active.

The following object sets up the Physical Memory Configuration Table:

Table 1081. Physical Memory Configuration Table

Name

Object ID

Description

Syntax

Access physicalMemoryConfigTable

1.3.6.1.4.1.674.10892.1.1300.30

Defines the Physical Memory Configuration Table.

SEQUENCE OF PhysicalMemoryConfigTableEntry

Not accessible

Table 1082. Physical Memory Configuration Table Entry

Name physicalMemoryConfigTableEntry

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.1300.30.1

Defines the Physical Memory Configuration Table entry.

PhysicalMemoryConfigTableEntry

Not accessible physicalMemoryConfigChassisIndex

, physicalMemoryConfigIndex

Server Administrator Group 249

Table 1083. Physical Memory Configuration Chassis Index

Name

Object ID

Description

Syntax

Access physicalMemoryConfigChassisIndex

1.3.6.1.4.1.674.10892.1.1300.30.1.1

Defines the index (one-based) of the chassis associated with the physical memory configuration.

DellObjectRange

Read-only

Table 1084. Physical Memory Configuration Index

Name

Object ID

Description

Syntax

Access physicalMemoryConfigIndex

1.3.6.1.4.1.674.10892.1.1300.30.1.2

Defines the index (one-based) of the physical memory configuration.

DellObjectRange

Read-only

Table 1085. Physical Memory Configuration State Capabilities

Name

Object ID

Description

Syntax

Access physicalMemoryConfigStateCapabilities

1.3.6.1.4.1.674.10892.1.1300.30.1.3

Defines the state capabilities of the physical memory configuration.

DellPhysicalMemoryConfigStateCapabilities

Read-only

Table 1086. Physical Memory Configuration State Settings

Name physicalMemoryConfigStateSettings

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1300.30.1.4

Defines the state settings of the physical memory configuration.

DellPhysicalMemoryConfigStateSettings

Read-only

Table 1087. Physical Memory Configuration Status

Name

Object ID

Description

Syntax

Access physicalMemoryConfigStatus

1.3.6.1.4.1.674.10892.1.1300.30.1.5

Defines the status of the physical memory configuration.

DellStatus

Read-only

Table 1088. Physical Memory Configuration Redundant Capabilities

Name

Object ID

Description

Syntax

Access physicalMemoryConfigRedundantCapabilities

1.3.6.1.4.1.674.10892.1.1300.30.1.6

Defines the redundant capabilities of the physical memory.

DellPhysicalMemoryConfigRedundantCapabilities

Read-only

250 Server Administrator Group

Table 1089. Physical Memory Configuration Redundant Settings

Name

Object ID

Description

Syntax

Access physicalMemoryConfigRedundantSettings

1.3.6.1.4.1.674.10892.1.1300.30.1.7

Defines the redundant settings of the physical memory.

DellPhysicalMemoryConfigRedundantSettings

Read-only

Table 1090. Physical Memory Configuration MOM Capabilities

Name

Object ID

Description

Syntax

Access physicalMemoryConfigMOMCapabilities

1.3.6.1.4.1.674.10892.1.1300.30.1.8

Defines the Memory Operating Mode capabilities of the physical memory.

DellPhysicalMemoryConfigMOMCapabilities

Read-only

Table 1091. Physical Memory Configuration MOM Settings

Name

Object ID

Description

Syntax

Access physicalMemoryConfigMOMSettings

1.3.6.1.4.1.674.10892.1.1300.30.1.9

Defines the Memory Operating Mode settings of the physical memory.

DellPhysicalMemoryConfigMOMSettings

Read-only

Physical Memory Logging Table

This table defines the conditions for logging system memory events.

The following object sets up the Physical Memory Logging Table:

Table 1092. Physical Memory Logging Table

Name physicalMemoryLoggingTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1300.40

Defines the Physical Memory Logging Table.

SEQUENCE OF PhysicalMemoryLoggingTableEntry

Not accessible

Table 1093. Physical Memory Logging Table Entry

Name

Object ID

Description

Syntax

Access

Index physicalMemoryLoggingTableEntry

1.3.6.1.4.1.674.10892.1.1300.40.1

Defines the Physical Memory Logging Table entry.

PhysicalMemoryLoggingTableEntry

Not accessible physicalMemoryLoggingChassisIndex

Server Administrator Group 251

Table 1093. Physical Memory Logging Table Entry (continued)

, physicalMemoryLoggingIndex

Table 1094. Physical Memory Logging Chassis Index

Name physicalMemoryLoggingChassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1300.40.1.1

Defines the index (one-based) of the chassis associated with the physical memory logging.

DellObjectRange

Read-only

Table 1095. Physical Memory Logging Index

Name

Object ID

Description

Syntax

Access physicalMemoryLoggingIndex

1.3.6.1.4.1.674.10892.1.1300.40.1.2

Defines the index (one-based) of the physical memory logging.

DellObjectRange

Read-only

Table 1096. Physical Memory Logging Capabilities

Name

Object ID

Description

Syntax

Access physicalMemoryLoggingCapabilities

1.3.6.1.4.1.674.10892.1.1300.40.1.3

Defines the capabilities of the physical memory logging.

DellPhysicalMemoryLoggingCapabilities

Read-only

Table 1097. Physical Memory Logging Settings

Name

Object ID

Description

Syntax

Access physicalMemoryLoggingSettings

1.3.6.1.4.1.674.10892.1.1300.40.1.4

Defines the settings of the physical memory logging.

DellPhysicalMemoryLoggingSettings

Read-only

Table 1098. Physical Memory Logging Status

Name

Object ID

Description

Syntax

Access physicalMemoryLoggingStatus

1.3.6.1.4.1.674.10892.1.1300.40.1.5

Defines the status of the physical memory logging.

DellStatus

Read-only

Redundant Memory Unit Table

This table reports the status of redundant memory within a particular system chassis.

252 Server Administrator Group

The following object sets up the Redundant Memory Unit Table:

Table 1099. Redundant Memory Unit Table

Name

Object ID

Description

Syntax

Access redundantMemoryUnitTable

1.3.6.1.4.1.674.10892.1.1300.50

Defines the Redundant Memory Unit Table.

SEQUENCE OF RedundantMemoryUnitTableEntry

Not accessible

Table 1100. Redundant Memory Unit Table Entry

Name

Object ID

Description

Syntax

Access

Index redundantMemoryUnitTableEntry

1.3.6.1.4.1.674.10892.1.1300.50.1

Defines the Redundant Memory Unit Table entry.

RedundantMemoryUnitTableEntry

Not accessible redundantMemoryUnitChassisIndex

, redundantMemoryUnitIndex

Table 1101. Redundant Memory Unit Chassis Index

Name

Object ID

Description

Syntax

Access redundantMemoryUnitChassisIndex

1.3.6.1.4.1.674.10892.1.1300.50.1.1

Defines the index (one-based) of the chassis associated with the redundant memory unit.

DellObjectRange

Read-only

Table 1102. Redundant Memory Unit Index

Name

Object ID

Description

Syntax

Access redundantMemoryUnitIndex

1.3.6.1.4.1.674.10892.1.1300.50.1.2

Defines the index (one-based) of the redundant memory unit.

DellObjectRange

Read-only

Table 1103. Redundant Memory Unit State Capabilities

Name

Object ID

Description

Syntax

Access redundantMemoryUnitStateCapabilities

1.3.6.1.4.1.674.10892.1.1300.50.1.3

Defines the state capabilities of the redundant memory unit.

DellStateCapabilities

Read-only

Server Administrator Group 253

Table 1104. Redundant Memory Unit State Settings

Name

Object ID

Description

Syntax

Access redundantMemoryUnitStatesettings

1.3.6.1.4.1.674.10892.1.1300.50.1.4

Defines the state settings of the redundant memory unit.

DellStateSettings

Read-only

Table 1105. Redundant Memory Unit Redundancy Status

Name

Object ID

Description

Syntax

Access redundantMemoryUnitRedundancyStatus

1.3.6.1.4.1.674.10892.1.1300.50.1.5

Defines the redundancy status of the redundant memory unit.

DellStatusRedundancy

Read-only

Table 1106. Redundant Memory Unit Name

Name

Object ID

Description

Syntax

Access redundantMemoryUnitName

1.3.6.1.4.1.674.10892.1.1300.50.1.6

Defines the name of the redundant memory unit.

DellString

Read-only

Table 1107. Redundant Memory Unit Status

Name

Object ID

Description

Syntax

Access redundantMemoryUnitStatus

1.3.6.1.4.1.674.10892.1.1300.50.1.7

Defines the status of the redundant memory unit.

DellStatus

Read-only

Physical Memory Card Table

This table defines the name of the memory card, the total number of device slots present on the memory card, and the number of memory device slots in use on the memory card.

The following objects set up the Physical Memory Card Table:

Table 1108. Physical Memory Card Table

Name

Object ID

Description

Syntax

Access physicalMemoryCardTable

1.3.6.1.4.1.674.10892.1.1300.60

Defines the Physical Memory Card Table.

SEQUENCE OF PhysicalMemoryCardTableEntry

Not accessible

Table 1109. Physical Memory Card Table Entry

Name physicalMemoryCardTableEntry

254 Server Administrator Group

Table 1109. Physical Memory Card Table Entry (continued)

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.1300.60.1

Defines the Physical Memory Card Table Entry.

PhysicalMemoryCardTableEntry

Not accessible physicalMemoryCardChassisIndex

, physicalMemoryCardIndex

Table 1110. Physical Memory Card Chassis Index

Name

Object ID

Description

Syntax

Access physicalMemoryCardChassisIndex

1.3.6.1.4.1.674.10892.1.1300.60.1.1

Defines the index (one-based) of the associated chassis.

DellObjectRange

Read-only

Table 1111. Physical Memory Card Index

Name

Object ID

Description

Syntax

Access physicalMemoryCardIndex

1.3.6.1.4.1.674.10892.1.1300.60.1.2

Defines the index (one-based) of the Physical Memory Card.

DellObjectRange

Read-only

Table 1112. Physical Memory Card State Capabilities

Name

Object ID

Description

Syntax

Access physicalMemoryCardStateCapabilities

1.3.6.1.4.1.674.10892.1.1300.60.1.3

Defines the state capabilities of the Physical Memory Card.

DellStateCapabilities

Read-only

Table 1113. Physical Memory Card State Settings

Name

Object ID

Description

Syntax

Access physicalMemoryCardStateSettings

1.3.6.1.4.1.674.10892.1.1300.60.1.4

Defines the state settings of the Physical Memory Card.

DellStateSettings

Read-only

Table 1114. Physical Memory Card Status

Name

Object ID

Description physicalMemoryCardStatus

1.3.6.1.4.1.674.10892.1.1300.60.1.5

Defines the status of the Physical Memory Card.

Server Administrator Group 255

Table 1114. Physical Memory Card Status (continued)

Syntax

Access

DellStatus

Read-only

Table 1115. Physical Memory Card Name

Name

Object ID

Description

Syntax

Access physicalMemoryCardName

1.3.6.1.4.1.674.10892.1.1300.60.1.6

Defines the name of the Physical Memory Card.

DellString

Read-only

Table 1116. Physical Memory Card Total Number Sockets

Name

Object ID

Description

Syntax

Access physicalMemoryCardTotalNumberSockets

1.3.6.1.4.1.674.10892.1.1300.60.1.7

Defines the total number of memory sockets available on the Physical Memory Card.

2,147,483,647 indicates an unknown number of sockets.

DellUnsigned32BitRange

Read-only

Table 1117. Physical Memory Card In Use Number Sockets

Name

Object ID

Description

Syntax

Access physicalMemoryCardInUseNumberSockets

1.3.6.1.4.1.674.10892.1.1300.60.1.8

Defines the number of memory sockets in use on the Physical Memory Card. Zero indicates that the Physical Memory Card is not installed or has a configuration error.

DellUnsigned32BitRange

Read-only

Table 1118. Physical Memory Card Physical Memory Array Index Reference

Name

Object ID

Description

Syntax

Access physicalMemoryCardPhyMemArrayIndexReference

1.3.6.1.4.1.674.10892.1.1300.60.1.9

Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with.

DellObjectRange

Read-only

Memory Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 1119. Physical Memory Array Location

Variable Name : DellPhysicalMemoryArrayLocation

Data Type : Integer

Possible Data Values Meaning of Data Value

256 Server Administrator Group

Table 1119. Physical Memory Array Location (continued) memoryArrayLocationIsOther(1) memoryArrayUseIsUnknown(2) memoryArrayUseIsSystemMemory(3) memoryArrayUseIsVideoMemory(4) memoryArrayUseIsFLASHMemory(5) memoryArrayUseIsNonVolatileRAMMemory(6) memoryArrayUseIsCacheMemory(7) memoryArrayLocationIsPCMCIA(8) memoryArrayLocationIsProprietary(9) memoryArrayLocationIsNUBUS(10) memoryArrayLocationIsPC98C20(11) memoryArrayLocationIsPC98C24(12) memoryArrayLocationIsPC98E(13) memoryArrayLocationIsPC98LocalBus(14) memoryArrayLocationIsPC98Card(15)

The memory array location is not one of the following:

The memory array use is unknown.

The memory array is system memory.

The memory array is video memory.

The memory array is FLASH memory.

The memory array is nonvolatile RAM.

The memory array is cache memory.

The memory array location is a Personal Computer Memory

Card International Association (PCMCIA) option card.

The memory array location is a proprietary option card.

The memory array location is a NuBus bus.

The memory array location is a PC-98/C20 option card.

The memory array location is a PC-98/C24 option card.

The memory array location is a PC-98/E option card.

The memory array location is a PC-98/Local bus option card.

The memory array location is a PC-98/Card slot option card.

Table 1120. Physical Memory Array ECC Type Definitions

Variable Name : DellPhysicalMemoryArrayECCType

Data Type : Integer

Possible Data Values memoryArrayECCTypeIsOther(1) memoryArrayECCTypeIsUnknown(2) memoryArrayECCTypeIsNone(3) memoryArrayECCTypeIsParity(4) memoryArrayECCTypeIsSingleBitECC(5) memoryArrayECCTypeIsMultiBitECC(6) memoryArrayECCTypeIsCRC(7)

Meaning of Data Value

There is not one of the following:

The memory array ECC type is unknown.

The memory array ECC type is none.

The memory array ECC type is parity.

The memory array ECC type is Correctable Memory Event

ECC.

The memory array ECC type is Uncorrectable Memory Event

ECC.

The memory array ECC type is CRC.

Table 1121. Physical Memory Configuration State Capabilities

Variable Name : DellPhysicalMemoryConfigStateCapabilities

Data Type : Integer

Possible Data Values Meaning of Data Value

If set to 0 (zero) unknownCapabilities(1) enableCapable(2) notReadyCapable(4)

There are no state capabilities.

State capabilities are unknown.

Object enable/disable is supported.

Object not ready is supported.

Server Administrator Group 257

Table 1122. Physical Memory Configuration State Settings

Variable Name : DellPhysicalMemoryConfigStateSettings

Data Type : Integer

Possible Data Values

If set to 0 (zero) unknown(1)

Meaning of Data Value

There are no state settings.

State settings are unknown.

enabled(2) notReady(4) redundantMemoryIsActive(8) enabledAndRedundantMemoryIsActive(10)

Object is disabled (offline) 0, or enabled (online) 1.

Object not ready .

Redundant memory is active (in use).

Redundant memory is enabled and in use.

Table 1123. Physical Memory Configuration Redundant Capabilities

Variable Name : DellPhysicalMemoryConfigRedundantCapabilities

Data Type : Integer

Possible Data Values Meaning of Data Value

If set to 0 (zero) unknownCapabilities(1)

The redundant capabilities are: spareCapable(2)

There are no redundant memory capabilities.

Redundant capabilities are unknown.

Spare redundant memory feature is supported.

mirrorCapable(4) spareAndMirrorCapable(6) raidCapable(8) dddcCapable(16)

Mirror redundant memory feature is supported.

Spare and mirror redundant memory features are supported.

Redundant Array of Independent disks (RAID) redundant memory feature is supported.

DDDC redundancy is supported.

Table 1124. Physical Memory Configuration Redundant Settings

Variable Name : DellPhysicalMemoryConfigRedundantSettings

Data Type : Integer

Possible Data Values Meaning of Data Value

If set to 0 (zero) unknown(1)

The following redundant settings are mutually exclusive:

There are no redundant memory settings enabled.

Redundant settings are unknown.

spareEnabled(2) mirrorEnabled(4) raidEnabled(8) dddcCapable(16)

Spare redundant memory feature is enabled.

Mirror redundant memory feature is enabled.

RAID redundant memory feature is enabled.

DDDC redundancy is enabled.

Table 1125. Physical Memory Logging Capabilities

Variable Name : DellPhysicalMemoryLoggingCapabilities

Data Type : Integer

Possible Data Values Meaning of Data Value

258 Server Administrator Group

Table 1125. Physical Memory Logging Capabilities (continued)

If set to 0 (zero) unknown Capabilities(1)

The logging capabilities are: enableCapable(2)

There are no logging capabilities.

Logging capabilities are unknown.

Logging enable/disable using Simple Network Management

Protocol (SNMP) is supported.

Table 1126. Physical Memory Logging Settings

Variable Name : DellPhysicalMemoryLoggingSettings

Data Type : Integer

Possible Data Values

If set to 0 (zero)

Meaning of Data Value

There are no logging settings enabled. unknown

Capabilities(1)

The logging settings are: enabled(2)

Logging capabilities are unknown.

Logging is disabled (0), or enabled (1).

BIOS Setup Control Group

Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature.

BIOS Setup Control Group Tables

The MIB tables in this group define the BIOS control of devices and controller cards that are typically present in a system.

BIOS Setup Control Table

SCSI Control Table

Parallel Port Control Table

Serial Port Control Table

USB Control Table

IDE Control Table

Diskette Control Table

Network Interface Control Table

The following MIB table in the BIOS Setup Control Group is supported on Dell PowerEdge xx2x (12G) systems:

BIOS Setting Table

BIOS Setup Control Group Tables

Table 1127. BIOS Setup Control Table

Name

Object ID

Description

Syntax

Access biosSetUpControlTable

1.3.6.1.4.1.674.10892.1.1400.10

Defines the set of single devices in a chassis controlled by the BIOS.

BiosSetUpControlTableEntry

Not accessible

Table 1128. BIOS Setup Control Table Entry

Name biosSetUpControlTableEntry

Server Administrator Group 259

Table 1128. BIOS Setup Control Table Entry (continued)

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.1400.10.1

Defines the BIOS Control Device Table entry.

BiosSetUpControlTableEntry

Not accessible biosSetUpControlchassisIndex

Table 1129. BIOS Setup Control Chassis Index

Name

Object ID

Description

Syntax

Access biosSetUpControlchassisIndex

1.3.6.1.4.1.674.10892.1.1400.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1130. BIOS Setup Control (BSUC) Pointing Device Control Capabilities

Name

Object ID

Description

Syntax

Access bSUCpointingDeviceControlCapabilities

1.3.6.1.4.1.674.10892.1.1400.10.1.2

Defines the capabilities of the pointing device.

DellStateCapabilities

Read-only

Table 1131. BIOS Setup Control Pointing Device Control Settings

Name

Object ID

Description

Syntax

Access bSUCpointingDeviceControlSettings

1.3.6.1.4.1.674.10892.1.1400.10.1.3

Defines the state of the pointing device.

DellStateSettings

Read-only

Table 1132. BIOS Setup Control Pointing Device Control Status

Name

Object ID

Description

Syntax

Access bSUCpointingDeviceControlStatus

1.3.6.1.4.1.674.10892.1.1400.10.1.4

Defines the status of the pointing device.

DellStatus

Read-only

Table 1133. BIOS Setup Control Pointing Device Control Name

Name

Object ID

Description

Syntax

Access bSUCpointingDeviceControlName

1.3.6.1.4.1.674.10892.1.1400.10.1.5

Defines the setup BIOS name of the pointing device.

DellString

Read-only

260 Server Administrator Group

Table 1134. BIOS Setup Control Numeric Lock Control Capabilities

Name

Object ID

Description

Syntax

Access bSUCnumLockControlCapabilities

1.3.6.1.4.1.674.10892.1.1400.10.1.6

Defines the capabilities of the numeric lock.

DellStateCapabilities

Read-only

Table 1135. BIOS Setup Control Numeric Lock Control Settings

Name

Object ID

Description

Syntax

Access bSUCnumLockControlSettings

1.3.6.1.4.1.674.10892.1.1400.10.1.7

Defines the state of the numeric lock.

DellStateSettings

Read-only

Table 1136. BIOS Setup Control Numeric Lock Control Status

Name

Object ID

Description

Syntax

Access bSUCnumLockControlStatus

1.3.6.1.4.1.674.10892.1.1400.10.1.8

Defines the status of the numeric lock.

DellStatus

Read-only

Table 1137. BIOS Setup Control Numeric Lock Control Name

Name

Object ID

Description

Syntax

Access bSUCnumLockControlName

1.3.6.1.4.1.674.10892.1.1400.10.1.9

Defines the setup BIOS name of the numeric lock.

DellString

Read-only

Table 1138. BIOS Setup Control Processor Serial Number Control Capabilities

Name

Object ID

Description

Syntax

Access bSUCprocessorSerialNumberControlCapabilities

1.3.6.1.4.1.674.10892.1.1400.10.1.10

Defines if the processor serial number can be returned.

DellStateCapabilities

Read-only

Table 1139. BIOS Setup Control Processor Serial Number Control Settings

Name

Object ID

Description

Syntax

Access bSUCprocessorSerialNumberControlSettings

1.3.6.1.4.1.674.10892.1.1400.10.1.11

Defines the state of the processor serial number.

DellStateSettings

Read-only

Server Administrator Group 261

Table 1140. BIOS Setup Control Processor Serial Number Control Status

Name

Object ID

Description

Syntax

Access bSUCprocessorSerialNumberControlStatus

1.3.6.1.4.1.674.10892.1.1400.10.1.12

Defines the status of the processor serial number.

DellStatus

Read-only

Table 1141. BIOS Setup Control Processor Serial Number Control Name

Name

Object ID

Description

Syntax

Access bSUCprocessorSerialNumberControlName

1.3.6.1.4.1.674.10892.1.1400.10.1.13

Defines the setup BIOS name of the processor serial number.

DellString

Read-only

Table 1142. BIOS Setup Control Speaker Control Capabilities Unique

Name

Object ID

Description

Syntax

Access bSUCspeakerControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.10.1.14

Defines the capabilities of the speaker control.

DellSpeakerControlCapabilitiesUnique (See

Speaker Control Capabilities Unique

)

Read-only

Table 1143. BIOS Setup Control Speaker Control Settings Unique

Name

Object ID

Description

Syntax

Access bSUCspeakerControlSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.10.1.15

Defines the settings available for speaker control.

DellSpeakerControlSettingsUnique (See

Speaker Control Settings Unique )

Read-only

Table 1144. BIOS Setup Control Speaker Control Status

Name

Object ID

Description

Syntax

Access bSUCspeakerControlStatus

1.3.6.1.4.1.674.10892.1.1400.10.1.16

Defines the status of speaker control.

DellStatus

Read-only

Table 1145. BIOS Setup Control Speaker Control Name

Name

Object ID

Description

Syntax

Access bSUCspeakerControlName

1.3.6.1.4.1.674.10892.1.1400.10.1.17

Defines the setup BIOS name of the speaker control.

DellString

Read-only

262 Server Administrator Group

Table 1146. BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique

Name

Object ID

Description

Syntax

Access bSUCnIFwakeonLanControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.10.1.18

Defines the defines the capabilities of the network interface function (NIF) Wakeup on

LAN.

DellNIFwakeonLanControlCapabilitiesUnique (See

Network Interface (NIF) Wakeup on

LAN Capabilities Unique

)

Read-only

Table 1147. BIOS Setup Control NIF Wakeup on LAN Control Settings Unique

Name bSUCnIFwakeonLanControlSettingsUnique

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1400.10.1.19

Defines the state of the NIF Wakeup on LAN.

DellNIFwakeonLanControlSettingsUnique (See

NIF Wakeup on LAN Control Settings

Unique

)

Read-only

Table 1148. BIOS Setup Control NIF Wakeup on LAN Control Status

Name

Object ID

Description

Syntax

Access bSUCnIFwakeonLanControlStatus

1.3.6.1.4.1.674.10892.1.1400.10.1.20

Defines the status of the NIF Wakeup on LAN.

DellStatus

Read-only

Table 1149. BIOS Setup Control NIF Wakeup on LAN Control Name

Name

Object ID

Description

Syntax

Access bSUCnIFwakeonLanControlName

1.3.6.1.4.1.674.10892.1.1400.10.1.21

Defines the setup BIOS name of the NIF Wakeup on LAN.

DellString

Read-only

Table 1150. BIOS Setup Control Boot Sequence Control Capabilities Unique

Name

Object ID

Description

Syntax

Access bSUCbootSequenceControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.10.1.22

Defines the capabilities of the boot sequence.

DellBootSequenceControlCapabilitiesUnique (See

Boot Sequence Control Capabilities

Unique

)

Read-only

Table 1151. BIOS Setup Control Boot Sequence Control Settings Unique

Name

Object ID

Description

Syntax

DellBootSequenceControlSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.10.1.23

Defines the state of the boot sequence.

DellBootSequenceControlSettingsUnique (See

Boot Sequence Control Settings Unique )

Server Administrator Group 263

Table 1151. BIOS Setup Control Boot Sequence Control Settings Unique (continued)

Access Read-only

Table 1152. BIOS Setup Control Boot Sequence Control Status

Name

Object ID

Description

Syntax

Access bSUCbootSequenceControlStatus

1.3.6.1.4.1.674.10892.1.1400.10.1.24

Defines the status of the boot sequence.

DellStatus

Read-only

Table 1153. BIOS Setup Control Boot Sequence Control Name

Name

Object ID

Description

Syntax

Access bSUCbootSequenceControlName

1.3.6.1.4.1.674.10892.1.1400.10.1.25

Defines the control name of the boot sequence.

DellString

Read-only

Table 1154. BIOS Setup Control Administrator Password Control Capabilities Unique

Name bSUCadministratorPasswordControlCapabilities Unique

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1400.10.1.26

Defines the capabilities of the administrator password control.

DellBIOSPasswordControlCapabilitiesUnique

Read-only

Table 1155. BIOS Setup Control Administrator Password Control Settings Unique

Name

Object ID

Description

Syntax

Access bSUCadministratorPasswordControlSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.10.1.27

Defines the settings for administrator password control.

DellBIOSPasswordControlSettingsUnique (See

BIOS Password Control Settings Unique

)

Read-only

Table 1156. BIOS Setup Control Administrator Password Control Status

Name

Object ID

Description

Syntax

Access bSUCadministratorPasswordControlStatus

1.3.6.1.4.1.674.10892.1.1400.10.1.28

Defines the status for administrator password control.

DellStatus

Read-only

Table 1157. BIOS Setup Control Administrator Password Verify Name

Name

Object ID

Description

Syntax bSUCadministratorPasswordVerifyName

1.3.6.1.4.1.674.10892.1.1400.10.1.29

Defines the setup BIOS name for the current administrator password.

DellString

264 Server Administrator Group

Table 1157. BIOS Setup Control Administrator Password Verify Name (continued)

Access Read-only

Table 1158. BIOS Setup Control Administrator Password New Password Name

Name

Object ID

Description

Syntax

Access bSUCadministratorPasswordNewPasswordName

1.3.6.1.4.1.674.10892.1.1400.10.1.30

Defines the setup BIOS name of the new administrator password. To set a new administrator password, you must have successfully set the current administrator password immediately preceding this password change.

DellString

Read-only

Table 1159. BIOS Setup Control User Password Control Capabilities Unique

Name

Object ID

Description

Syntax

Access bSUCuserPasswordControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.10.1.31

Defines the capabilities of user password control.

DellBIOSPasswordControlCapabilitiesUnique

Read-only

Table 1160. BIOS Setup Control User Password Control Settings Unique

Name

Object ID

Description

Syntax

Access bSUCuserPasswordControlSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.10.1.32

Defines the control settings for user password control.

DellBIOSPasswordControlSettingsUnique (See

BIOS Password Control Settings

)

Read-Only

Table 1161. BIOS Setup Control User Password Control Status

Name

Object ID

Description

Syntax

Access bSUCuserPasswordControlStatus

1.3.6.1.4.1.674.10892.1.1400.10.1.33

Defines the status of the user password control.

DellStatus

Read-only

Table 1162. BIOS Setup Control User Password Verify Name

Name

Object ID

Description

Syntax

Access bSUCuserPasswordVerifyName

1.3.6.1.4.1.674.10892.1.1400.10.1.34

Defines the setup BIOS name of the current user password.

DellString

Read-Only

Table 1163. BIOS Setup Control User Password New Password Name

Name

Object ID bSUCuserPasswordNewPasswordName

1.3.6.1.4.1.674.10892.1.1400.10.1.35

Server Administrator Group 265

Table 1163. BIOS Setup Control User Password New Password Name (continued)

Description

Syntax

Access

Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user password immediately preceding this password change.

DellString

Read-Only

Table 1164. BIOS Setup Control TPM Security Control Capabilities

Name

Object ID

Description

Syntax

Access bSUCtpmSecurityControlCapabilities

1.3.6.1.4.1.674.10892.1.1400.10.1.36

Defines the BIOS setup control capabilities of Trusted Platform Module (TPM) security.

DellTPMSecurityControlCapabilities

Read-only

Table 1165. BIOS Setup Control TPM Security Control Setting

Name

Object ID

Description

Syntax

Access bSUCtpmSecurityControlSetting

1.3.6.1.4.1.674.10892.1.1400.10.1.37

Defines the BIOS setup control setting of Trusted Platform Module (TPM) security.

DellTPMSecurityControlSetting

Read-only

Table 1166. BIOS Setup Control TPM Security Control Status

Name

Object ID

Description

Syntax

Access bSUCtpmSecurityControlStatus

1.3.6.1.4.1.674.10892.1.1400.10.1.38

Defines the BIOS setup control status of Trusted Platform Module (TPM) security.

DellStatus

Read-only

Table 1167. BIOS Setup Control TPM Security Control Name

Name

Object ID

Description

Syntax

Access bSUCtpmSecurityControlName

1.3.6.1.4.1.674.10892.1.1400.10.1.39

Defines the BIOS setup control name of Trusted Platform Module (TPM) security.

DellString

Read-only

SCSI Control Table

Table 1168. SCSI Control Table

Name

Object ID

Description

Syntax

Access sCSIControlTable

1.3.6.1.4.1.674.10892.1.1400.20

Defines the Small Computer System Interface (SCSI) Control Table.

SCSIControlTableEntry

Not accessible

266 Server Administrator Group

Table 1169. SCSI Control Table Entry

Name

Object ID

Description x

Syntax

Access

Index sCSIControlTableEntry

1.3.6.1.4.1.674.10892.1.1400.20.1

Defines the SCSI Control Table entry.

SCSIControlTableEntry

Not accessible sCSIControlchassisIndex

, sCSIControlIndex

Table 1170. SCSI Control Chassis Index

Name

Object ID

Description

Syntax

Access sCSIControlchassisIndex

1.3.6.1.4.1.674.10892.1.1400.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1171. SCSI Control Index

Name

Object ID

Description

Syntax

Access sCSIControlIndex

1.3.6.1.4.1.674.10892.1.1400.20.1.2

Defines the index (one-based) of the SCSI controller in this chassis.

DellObjectRange

Read-only

Table 1172. SCSI Control Capabilities

Name

Object ID

Description

Syntax

Access sCSIControlCapabilities

1.3.6.1.4.1.674.10892.1.1400.20.1.3

Defines the capabilities of the SCSI controller.

DellStateCapabilities

Read-only

Table 1173. SCSI Control Settings

Name

Object ID

Description

Syntax

Access sCSIControlSettings

1.3.6.1.4.1.674.10892.1.1400.20.1.4

Defines the state of the SCSI controller.

DellStateSettings

Read-only

Table 1174. SCSI Control Status

Name

Object ID sCSIControlStatus

1.3.6.1.4.1.674.10892.1.1400.20.1.5

Server Administrator Group 267

Table 1174. SCSI Control Status (continued)

Description

Syntax

Access

Defines the status of the SCSI controller.

DellStatus

Read-only

Table 1175. SCSI Control Name

Name

Object ID

Description

Syntax

Access sCSIControlName

1.3.6.1.4.1.674.10892.1.1400.20.1.6

Defines the setup BIOS name of the SCSI controller.

DellString

Read-only

Parallel Port Control Table

Table 1176. Parallel Port Control Table

Name parallelPortControlTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1400.30

Defines the Parallel Port Control Table.

ParallelPortControlTableEntry

Not accessible

Table 1177. Parallel Port Control Table Entry

Name

Object ID

Description

Syntax

Access

Index parallelPortControlTableEntry

1.3.6.1.4.1.674.10892.1.1400.30.1

Defines the Parallel Port Control Table entry.

ParallelPortControlTableEntry

Not accessible parallelPortControlchassisIndex

, parallelPortControlIndex

Table 1178. Parallel Port Control Chassis Index

Name parallelPortControlchassisIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1400.30.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1179. Parallel Port Control Index

Name

Object ID parallelPortControlIndex

1.3.6.1.4.1.674.10892.1.1400.30.1.2

268 Server Administrator Group

Table 1179. Parallel Port Control Index (continued)

Description

Syntax

Access

Defines the index (one-based) of the parallel port in this chassis.

DellObjectRange

Read-only

Table 1180. Parallel Port Control Capabilities Unique

Name

Object ID

Description

Syntax

Access parallelPortControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.30.1.3

Defines the capabilities of the parallel port.

DellParallelPortControlCapabilitiesUnique (See

Parallel Port Control Capabilities

)

Read-only

Table 1181. Parallel Port Control Settings Unique

Name

Object ID

Description

Syntax

Access parallelPortControlSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.30.1.4

Defines the state of the parallel port.

DellParallelPortControlSettingsUnique (See

Parallel Port Control Settings

)

Read-only

Table 1182. Parallel Port Control Status

Name

Object ID

Description

Syntax

Access parallelPortControlStatus

1.3.6.1.4.1.674.10892.1.1400.30.1.5

Defines the status of the parallel port.

DellStatus

Read-only

Table 1183. Parallel Port Control Name

Name

Object ID

Description

Syntax

Access parallelPortControlName

1.3.6.1.4.1.674.10892.1.1400.30.1.6

Defines the setup BIOS name of the parallel port.

DellString

Read-only

Table 1184. Parallel Port Control Mode Capabilities Unique

Name

Object ID

Description

Syntax

Access parallelPortControlModeCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.30.1.7

Defines the mode capabilities of the parallel port.

DellParallelPortControlModeCapabilitiesUnique

Read-only

Table 1185. Parallel Port Control Mode Settings Unique

Name

Object ID parallelPortControlModeSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.30.1.8

Server Administrator Group 269

Table 1185. Parallel Port Control Mode Settings Unique (continued)

Description

Syntax

Access

Defines the mode settings of the parallel port.

DellParallelPortControlModeSettingsUnique (See

Parallel Port Control Mode Settings

)

Read-only

Serial Port Control Table

Table 1186. Serial Port Control Table

Name

Object ID

Description

Syntax

Access serialPortControlTable

1.3.6.1.4.1.674.10892.1.1400.40

Defines the Serial Port Control Table.

SerialPortControlTableEntry

Not accessible

Table 1187. Serial Port Control Table Entry

Name serialPortControlTableEntry

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.1400.40.1

Defines the Serial Port Control Table entry.

SerialPortControlTableEntry

Not accessible serialPortControlchassisIndex

, serialPortControlIndex

Table 1188. Serial Port Control Chassis Index

Name

Object ID

Description

Syntax

Access serialPortControlchassisIndex

1.3.6.1.4.1.674.10892.1.1400.40.1.1

Defines index (one-based) of this chassis.

DellObjectRange read-only

Table 1189. Serial Port Control Index

Name serialPortControlIndex

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1400.40.1.2

Defines the index (one-based) of the serial port in this chassis.

DellObjectRange read-only

Table 1190. Serial Port Control Capabilities Unique

Name

Object ID serialPortControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.40.1.3

270 Server Administrator Group

Table 1190. Serial Port Control Capabilities Unique (continued)

Description

Syntax

Access

Defines the capabilities of the serial port.

DellSerialPortControlCapabilitiesUnique (See

Serial Port Control Capabilities

)

Read-only

Table 1191. Serial Port Control Settings Unique

Name

Object ID

Description

Syntax

Access serialPortControlSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.40.1.4

Defines the settings of the serial port.

DellSerialPortControlSettingsUnique (See Serial Port Control Settings

)

Read-only

Table 1192. Serial Port Control Status

Name

Object ID

Description

Syntax

Access serialPortControlStatus

1.3.6.1.4.1.674.10892.1.1400.40.1.5

Defines the status of the serial port.

DellStatus

Read-only

Table 1193. Serial Port Control Name

Name

Object ID

Description

Syntax

Access serialPortControlName

1.3.6.1.4.1.674.10892.1.1400.40.1.6

Defines the setup BIOS name of the serial port.

DellString

Read-only

USB Control Table

These objects enable you to track the attributes of your Universal Serial Bus (USB).

Table 1194. USB Control Table

Name

Object ID

Description

Syntax

Access usbControlTable

1.3.6.1.4.1.674.10892.1.1400.50

Defines the USB Table.

UsbControlTableEntry

Not accessible

Table 1195. USB Control Table Entry

Name

Object ID

Description

Syntax

Access usbControlTableEntry

1.3.6.1.4.1.674.10892.1.1400.50.1

Defines the USB Table entry.

UsbControlTableEntry

Not accessible

Server Administrator Group 271

Table 1195. USB Control Table Entry (continued)

Index usbControlchassisIndex

, usbControlIndex

Table 1196. USB Control Chassis Index

Name

Object ID

Description

Syntax

Access usbControlchassisIndex

1.3.6.1.4.1.674.10892.1.1400.50.1.1

Defines index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1197. USB Control Index

Name

Object ID

Description

Syntax

Access usbControlIndex

1.3.6.1.4.1.674.10892.1.1400.50.1.2

Defines the index (one-based) of the USB in this chassis.

DellObjectRange

Read-only

Table 1198. USB Control Capabilities

Name usbControlCapabilities

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1400.50.1.3

Defines the capabilities of the USB.

DellStateCapabilities

Read-only

Table 1199. USB Control Settings

Name

Object ID

Description

Syntax

Access usbControlSettings

1.3.6.1.4.1.674.10892.1.1400.50.1.4

Defines the control settings for the USB.

DellStateSettings

Read-only

Table 1200. USB Control Status

Name

Object ID

Description

Syntax

Access usbControlStatus

1.3.6.1.4.1.674.10892.1.1400.50.1.5

Defines the status of the USB.

DellStatus

Read-only

272 Server Administrator Group

Table 1201. USB Control Name

Name

Object ID

Description

Syntax

Access usbControlName

1.3.6.1.4.1.674.10892.1.1400.50.1.6

Defines the setup BIOS name of the USB.

DellString

Read-only

IDE Control Table

These objects enable you to track the attributes of Integrated Device Electronics (IDE) controller cards in your system.

Table 1202. IDE Control Table

Name

Object ID

Description

Syntax

Access ideControlTable

1.3.6.1.4.1.674.10892.1.1400.60

Defines the IDE Control Table.

IdeControlTableEntry

Not accessible

Table 1203. IDE Control Table Entry

Name

Object ID

Description

Syntax

Access

Index ideControlTableEntry

1.3.6.1.4.1.674.10892.1.1400.60.1

Defines the IDE Control Table entry.

IdeControlTableEntry

Not accessible ideControlchassisIndex

, ideControlIndex

Table 1204. IDE Control Chassis Index

Name

Object ID

Description

Syntax

Access ideControlchassisIndex

1.3.6.1.4.1.674.10892.1.1400.60.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1205. IDE Control Index

Name

Object ID

Description

Syntax

Access ideControlIndex

1.3.6.1.4.1.674.10892.1.1400.60.1.2

Defines the index (one-based) of the IDE controller in this chassis.

DellObjectRange

Read-only

Server Administrator Group 273

Table 1206. IDE Control Capabilities Unique

Name

Object ID

Description

Syntax

Access ideControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.60.1.3

Defines the capabilities of the IDE controller.

DellideControlCapabilitiesUnique (See

IDE Control Capabilities )

Read-only

Table 1207. IDE Control Settings Unique

Name

Object ID

Description

Syntax

Access ideControlSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.60.1.4

Defines the settings for the IDE controller.

DellideControlCapabilitiesUnique (See

IDE Control Capabilities )

Read-only

Table 1208. IDE Control Status

Name

Object ID

Description

Syntax

Access ideControlStatus

1.3.6.1.4.1.674.10892.1.1400.60.1.5

Defines the status for the IDE controller.

DellStatus

Read-only

Table 1209. IDE Control Name

Name

Object ID

Description

Syntax

Access ideControlName

1.3.6.1.4.1.674.10892.1.1400.60.1.6

Defines the setup BIOS name for the IDE controller.

DellStatus

Read-only

Diskette Control Table

Table 1210. Diskette Control Table

Name

Object ID

Description

Syntax

Access disketteControlTable

1.3.6.1.4.1.674.10892.1.1400.70

Defines the Diskette Control Table.

DisketteControlTableEntry

Not accessible

Table 1211. Diskette Control Table Entry

Name

Object ID

Description

Syntax disketteControlTableEntry

1.3.6.1.4.1.674.10892.1.1400.70.1

Defines the Diskette Control Table entry.

DellStatus

274 Server Administrator Group

Table 1211. Diskette Control Table Entry (continued)

Access

Index

Not accessible disketteControlchassisIndex

, disketteControlIndex

Table 1212. Diskette Control Chassis Index

Name

Object ID

Description

Syntax

Access disketteControlchassisIndex

1.3.6.1.4.1.674.10892.1.1400.70.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1213. Diskette Control Index

Name

Object ID

Description

Syntax

Access disketteControlIndex

1.3.6.1.4.1.674.10892.1.1400.70.1.2

Defines the index of the diskette controllers in this chassis.

DellObjectRange

Read-only

Table 1214. Diskette Control Capabilities Unique

Name

Object ID

Description

Syntax

Access disketteControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.70.1.3

Defines the capabilities of the diskette controller.

DellDisketteControlCapabilitiesUnique

Read-only

Table 1215. Diskette Control Settings Unique

Name

Object ID

Description

Syntax

Access disketteControlSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.70.1.4

Defines the control settings for the diskette controller.

DellDisketteControlSettingsUnique (See

Diskette Control Settings )

Read-only

Table 1216. Diskette Control Status

Name disketteControlStatus

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1400.70.1.5

Defines the status of the diskette controller.

DellStatus

Read-only

Server Administrator Group 275

Table 1217. Diskette Control Name

Name

Object ID

Description

Syntax

Access disketteControlName

1.3.6.1.4.1.674.10892.1.1400.70.1.6

Defines the setup BIOS name of the diskette controller.

DellString

Read-only

Network Interface Control Table

These MIB objects enable you to track the attributes of the NIC card for your system.

Table 1218. Network Interface Control Table

Name

Object ID

Description

Syntax

Access networkInterfaceControlTable

1.3.6.1.4.1.674.10892.1.1400.80

Defines the Network Interface Control Table.

NetworkInterfaceControlTableEntry

Not accessible

Table 1219. Network Interface Control Table Entry

Name

Object ID

Description

Syntax

Access

Index networkInterfaceControlTableEntry

1.3.6.1.4.1.674.10892.1.1400.80.1

Defines the Network Interface Control Table entry.

NetworkInterfaceControlTableEntry

Not accessible networkInterfaceControlchassisIndex

, networkInterfaceControlIndex

Table 1220. Network Interface Control Chassis Index

Name

Object ID

Description

Syntax

Access networkInterfaceControlchassisIndex

1.3.6.1.4.1.674.10892.1.1400.80.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1221. Network Interface Control Index

Name

Object ID

Description

Syntax

Access networkInterfaceControlIndex

1.3.6.1.4.1.674.10892.1.1400.80.1.2

Defines the index (one-based) of the network interface controller in this chassis.

DellObjectRange

Read-only

276 Server Administrator Group

Table 1222. Network Interface Control Capabilities Unique

Name

Object ID

Description

Syntax

Access networkInterfaceControlCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1400.80.1.3

Defines the capabilities of the NIC.

DellNetworkInterfaceControlCapabilitiesUnique (See Network Interface Control

Capabilities

)

Read-only

Table 1223. Network Interface Control Settings Unique

Name

Object ID

Description

Syntax

Access networkInterfaceControlSettingsUnique

1.3.6.1.4.1.674.10892.1.1400.80.1.4

Defines the control settings for the NIC.

DellNetworkInterfaceControlSettingsUnique (See

Network Interface Control Settings

)

Read-only

Table 1224. Network Interface Control Status

Name

Object ID

Description

Syntax

Access networkInterfaceControlStatus

1.3.6.1.4.1.674.10892.1.1400.80.1.5

Defines the status of the NIC.

DellStatus

Read-only

Table 1225. Network Interface Control Name

Name networkInterfaceControlName

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1400.80.1.6

Defines the setup BIOS name of the NIC.

DellString

Read-only

BIOS Setting Table

These MIB objects enable you to track the BIOS settings for your system.

NOTE: These MIB objects are supported on Dell PowerEdge xx2x systems.

Table 1226. BIOS Setting Table

Name

Object ID

Description

Syntax

Access biosSettingTable

1.3.6.1.4.1.674.10892.1.1400.90

Defines the BIOS Setting Table.

SEQUENCE OF BiosSettingTableEntry

Not accessible

Table 1227. BIOS Setting Table Entry

Name biosSettingTableEntry

Server Administrator Group 277

Table 1227. BIOS Setting Table Entry (continued)

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.1400.90.1

Defines the BIOS Setting Table Entry.

BiosSettingTableEntry

Not accessible biosSettingChassisIndex

, biosSettingIndex

Table 1228. BIOS Setting Chassis Index

Name

Object ID

Description

Syntax

Access biosSettingChassisIndex

1.3.6.1.4.1.674.10892.1.1400.90.1.1

Defines the index (one based) of the associated chassis.

DellObjectRange

Read-only

Table 1229. BIOS Setting Index

Name

Object ID

Description

Syntax

Access biosSettingIndex

1.3.6.1.4.1.674.10892.1.1400.90.1.2

Defines the index (one based) of the BIOS setting.

DellObjectRange

Read-only

Table 1230. BIOS Setting Name

Name

Object ID

Description

Syntax

Access biosSettingName

1.3.6.1.4.1.674.10892.1.1400.90.1.3

Defines the name of the BIOS setting.

DisplayString

Read-only

Table 1231. BIOS Setting Display Name

Name

Object ID

Description

Syntax

Access biosSettingDisplayName

1.3.6.1.4.1.674.10892.1.1400.90.1.4

Defines the display name of the BIOS setting.

DisplayString

Read-only

Table 1232. BIOS Setting Value Type

Name

Object ID

Description biosSettingValueType

1.3.6.1.4.1.674.10892.1.1400.90.1.5

Defines the type of the BIOS setting value.

278 Server Administrator Group

Table 1232. BIOS Setting Value Type (continued)

Syntax

Access

DellBIOSSettingValueType

Read-only

Table 1233. BIOS Setting Current Value

Name

Object ID

Description

Syntax

Access biosSettingCurrentValue

1.3.6.1.4.1.674.10892.1.1400.90.1.6

Defines the current value of the BIOS setting.

DisplayString

Read-only

Table 1234. BIOS Setting Pending Value

Name

Object ID

Description

Syntax

Access biosSettingPendingValue

1.3.6.1.4.1.674.10892.1.1400.90.1.7

Defines the pending value of the BIOS setting.

DisplayString

Read-only

Table 1235. BIOS Setting Default Value

Name

Object ID

Description

Syntax

Access biosSettingDefaultValue

1.3.6.1.4.1.674.10892.1.1400.90.1.8

Defines the default value of the BIOS setting.

DisplayString

Read-only

Table 1236. BIOS Setting Possible Values

Name

Object ID

Description

Syntax

Access biosSettingPossibleValues

1.3.6.1.4.1.674.10892.1.1400.90.1.9

Defines the possible values of the BIOS setting.

DisplayString

Read-only

Table 1237. BIOS Setting Display Order

Name biosSettingDisplayOrder

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1400.90.1.10

Defines the recommended display order of the BIOS setting within its BIOS setting group.

DellUnsigned32BitRange

Read-only

Table 1238. BIOS Setting Group Display Name

Name

Object ID biosSettingGroupDisplayName

1.3.6.1.4.1.674.10892.1.1400.90.1.11

Server Administrator Group 279

Table 1238. BIOS Setting Group Display Name (continued)

Description

Syntax

Access

Defines the display name of the BIOS setting group for the BIOS setting.

DisplayString

Read-only

Table 1239. BIOS Setting FQDD

Name

Object ID

Description

Syntax

Access biosSettingFQDD

1.3.6.1.4.1.674.10892.1.1400.90.1.12

Fully Qualified Device Descriptor (FQDD) for the BIOS setting.

DisplayString

Read-only

BIOS Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 1240. Speaker Control Capabilities Unique

Variable Name : DellSpeakerControlCapabilitiesUnique

Data Type : Integer

Possible Data Values Meaning of Data Value unknown(1) enableCapable(2) lowCapable(4) mediumCapable(8) highCapable(16) allVolumeCapable(30)

Speaker control capabilities are unknown.

Setup BIOS can enable speaker control.

Setup BIOS can set the speaker volume to low.

Setup BIOS can set the speaker volume to medium.

Setup BIOS can set the speaker volume to high.

Setup BIOS can set the speaker volume to any of the three settings.

Table 1241. Speaker Control Settings Unique

Variable Name : DellSpeakerControlSettingsUnique

Data Type : Integer

Possible Data Values unknown(1) enabled(2) low(4) medium(8) high(16)

Meaning of Data Value

Speaker control state is unknown.

Speaker control is enabled.

Speaker control volume is low.

Speaker control volume is medium.

Speaker control volume is high.

Table 1242. Network Interface (NIF) Wakeup on LAN Capabilities Unique

Variable Name : DellNIFwakeonLanControlCapabilitiesUnique

Data Type : Integer

Possible Data Values Meaning of Data Value

280 Server Administrator Group

Table 1242. Network Interface (NIF) Wakeup on LAN Capabilities Unique (continued) unknown(1) enableCapable(2) addInCardCapable(4) onBoardCapable(8) bothCapable(14)

Setup BIOS Wakeup on LAN capabilities are unknown.

Setup BIOS is capable of enabling the NIF Wakeup on LAN.

Setup BIOS is capable of enabling Wakeup on LAN by option card.

Setup BIOS is capable of enabling Wakeup on LAN by integrated NIF.

Setup BIOS is capable of enabling Wakeup on LAN by either option card or integrated NIF.

Table 1243. NIF Wakeup on LAN Control Settings Unique

Variable Name : DellNIFwakeonLanControlSettingsUnique

Data Type : Integer

Possible Data Values Meaning of Data Value unknown(1) enabled(2) addInCard(4) onBoard(8) addInCardOrOnBoard(12)

NIF Wakeup on LAN state is unknown.

NIF Wakeup on LAN is enabled.

NIF Wakeup on LAN is by option card.

NIF Wakeup on LAN is by integrated NIF.

NIF Wakeup on LAN is by option card or integrated NIF.

Table 1244. Boot Sequence Control Capabilities Unique

Variable Name : DellBootSequenceControlCapabilitiesUnique

Data Type : Integer

Possible Data Values bootSequenceUnknown(1) bootFromDisketteFirstCapable (2)

Meaning of Data Value

Boot sequence capabilities are unknown.

Setup BIOS can boot from a diskette first.

bootFromhardDriveFirstCapable (4) Setup BIOS can boot from an IDE hard drive first.

bootFromDisketteORHardDrive FirstCapable(6) Setup BIOS can boot from a diskette or an IDE hard drive first.

bootFromDeviceListCapable(8) bootFromCDROMFirstCapable(16) allFirstCapable(30)

Setup BIOS can boot from a device list.

Setup BIOS can boot from a CD first.

Setup BIOS can boot by any of the preceding methods first.

Table 1245. Boot Sequence Control Settings Unique

Variable Name : DellBootSequenceControlSettingsUnique

Data Type : Integer

Possible Data Values bootSequenceUnknown(1) bootFromDisketteFirst(2)

Meaning of Data Value

Boot sequence state is unknown.

Setup BIOS is set to boot by diskette first.

bootFromHardDriveFirst(4) bootFromDeviceList(8) bootFromCDROMFirst(16)

Setup BIOS is set to boot by IDE hard drive first.

Setup BIOS is set to boot by a device list.

Setup BIOS is set to boot by CD first.

Server Administrator Group 281

Table 1246. BIOS Password Control Capabilities

Variable Name : DellBIOSPasswordControlCapabilities

Data Type : Integer

Possible Data Values passwordControlCapabilitiesUn known(1)

Meaning of Data Value

BIOS password capabilities are unknown.

passwordControlEnableCapable (2) passwordControlJumperDisable Capable(4) passwordControlEnableANDJumper

DisableCapable(6)

Setup BIOS is capable of enabling password changes.

Setup BIOS is capable of determining if password control can be jumper disabled.

Setup BIOS is capable of enabling password changes and of determining if password control can be jumper disabled.

Table 1247. BIOS Password Control Settings Unique

Variable Name : DellBIOSPasswordControlSettingsUnique

Data Type : Integer

Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) passwordControlEnabled(2) passwordControlJumperDisabled(4)

Setup BIOS password state is unknown.

Setup BIOS has password changes enabled.

Setup BIOS has determined that password control has been disabled by a jumper.

Table 1248. BIOS Password Control Settings

Variable Name : DellBIOSPasswordControlSettingsUnique

Data Type : Integer

Possible Data Values passwordControlSettingsUnknown(1)

Meaning of Data Value

Setup BIOS password state is unknown.

passwordControlEnabled(2) passwordControlJumperDisabled(4)

Setup BIOS has password changes enabled.

Setup BIOS has determined that password control has been disabled by a jumper.

Table 1249. TPM Security Control Capabilities

Variable Name : DellTPMSecurityControlCapabilities

Data Type : Integer

Possible Data Values offCapable(1)

Meaning of Data Value

TPM security can be Off.

onWithPrebootMeasurementsCap able(2) onWithoutPrebootMeasurements Capable(4)

TPM security can be On with Pre-boot Measurements.

TPM security can be On without Pre-boot Measurements.

Table 1250. TPM Security Control Setting

Variable Name : DellTPMSecurityControlSetting

Data Type : Integer

Possible Data Values off(0) onWithPrebootMeasurements(1)

Meaning of Data Value

TPM security is Off .

TPM security is On with Pre-boot Measurements .

282 Server Administrator Group

Table 1250. TPM Security Control Setting (continued) onWithoutPrebootMeasurements (2) TPM security is On without Pre-boot Measurements .

Table 1251. Parallel Port Control Capabilities

Variable Name : DellParallelPortControlCapabilitiesUnique

Data Type : Integer

Possible Data Values unknown(1) enableCapable(2)

Meaning of Data Value

Setup BIOS parallel port capabilities are unknown.

Setup BIOS can enable the parallel port.

lpt1Capable(4) lpt1andEnableCapable(6) lpt2Capable(8)

Setup BIOS can support parallel port 1.

Setup BIOS has enabled parallel port 1.

Setup BIOS can support parallel port 2.

lpt2andEnableCapable(10) lpt3Capable(16) lpt3andEnableCapable(18) allParallelPortCapable(30)

Setup BIOS has enabled parallel port 2.

Setup BIOS can support parallel port 3.

Setup BIOS has enabled parallel port 3.

Setup BIOS can support any of the three parallel ports.

Table 1252. Parallel Port Control Settings

Variable Name : DellParallelPortControlSettingsUnique

Data Type : Integer

Possible Data Values unknown(1) enabled(2) lpt1(4)

Meaning of Data Value

Parallel port state is unknown.

Setup BIOS has enabled the parallel port.

Setup BIOS supports parallel port 1.

lpt1Enabled(6) lpt2(8) lpt2Enabled(10) lpt3(16)

Setup BIOS has enabled parallel port 1.

Setup BIOS supports parallel port 2.

Setup BIOS has enabled parallel port 2.

Setup BIOS supports parallel port 3.

Table 1253. Parallel Port Control Mode Settings

Variable Name : DellParallelPortControlModeSettingsUnique

Data Type : Integer

Possible Data Values unknown(1)

Meaning of Data Value

Parallel port mode is unknown.

atModeEnabled(2) ps2ModeEnabled(4) ecpModeEnabled(8) eppModeEnabled(16)

Setup BIOS has set the parallel port to AT mode.

Setup BIOS has set the parallel port to Personal Systems/2

(PS/2) mode.

Setup BIOS has set the parallel port to Extended Capabilities

Port (ECP) mode.

Setup BIOS has set the parallel port to Enhanced Parallel Port

(EPP) mode.

Server Administrator Group 283

Table 1254. Serial Port Control Capabilities

Variable Name : DellSerialPortControlCapabilitiesUnique

Data Type : Integer

Possible Data Values unknown(1) enableCapable(2)

Meaning of Data Value

Setup BIOS serial port capabilities are unknown.

Setup BIOS can enable the serial port.

com1Capable(4) enableAndCom1Capable(6) com2Capable(8) enableAndCom2Capable(10) com3Capable(16) enableAndCom3Capable(18) com4Capable(32)

Setup BIOS can support serial port 1.

Setup BIOS can enable serial port 1.

Setup BIOS can support serial port 2.

Setup BIOS is capable of enabling serial port 2.

Setup BIOS can support serial port 3.

Setup BIOS is capable of enabling serial port 3.

Setup BIOS can support serial port 4.

enableAndCom4Capable(34) autoConfigCapable(64)

Setup BIOS is capable of enabling serial port 4.

Setup BIOS is capable of autoconfiguring all serial ports.

com1OrCom3CapableAndAuto ConfigCapable(86) Setup BIOS has enabled autoconfiguration of COM1 and

COM3 serial ports.

com2OrCom4CapableAndAuto ConfigCapable(106) Setup BIOS has enabled autoconfiguration of COM2 and

COM4 serial ports.

allcomCapable(126) Setup BIOS is capable of enabling or autoconfiguring all serial ports.

Table 1255. Serial Port Control Settings

Variable Name : DellSerialPortControlSettingsUnique

Data Type : Integer

Possible Data Values Meaning of Data Value unknown(1) enabled(2) com1(4) com1Enabled(6)

Serial port state is unknown.

Setup BIOS has enabled the serial port.

Setup BIOS has selected serial port 1.

Setup BIOS has enabled serial port 1.

com2(8) com2Enabled(10) com3(16) com3Enabled(18) com4(32) com4Enabled(34) comPortsAutoConfig(64) enabledAndAutoConfig(66)

Setup BIOS has selected serial port 2.

Setup BIOS has enabled serial port 2.

Setup BIOS has selected serial port 3.

Setup BIOS has enabled serial port 3.

Setup BIOS has selected serial port 4.

Setup BIOS has enabled serial port 4.

Setup BIOS has selected autoconfiguration of serial ports.

Setup BIOS has enabled autoconfiguration of serial ports.

Table 1256. IDE Control Capabilities

Variable Name : DellideControlCapabilitiesUnique

284 Server Administrator Group

Table 1256. IDE Control Capabilities (continued)

Data Type : Integer

Possible Data Values unknown(1) ideControlAutoConfigOrEnable Capable(2)

Meaning of Data Value

IDE control capabilities are unknown.

IDE controller is autoconfigurable or enable capable.

Table 1257. Diskette Control Settings

Variable Name : DellDisketteControlSettingsUnique

Data Type : Integer

Possible Data Values Meaning of Data Value

Diskette control state is unknown.

unknown(1) disketteControlAutoConfigEnabled

OrEnabled(2)

Diskette control is set as autoconfigurable or enabled.

Table 1258. Network Interface Control Capabilities

Variable Name : DellNetworkInterfaceControlCapabilitiesUnique

Data Type : Integer

Possible Data Values unknown(1) enableCapable(2) enableWithoutPXECapable(4)

Meaning of Data Value

Unknown setup BIOS network interface capabilities.

Setup BIOS is capable of enabling the network interface.

Setup BIOS is capable of enabling the NIF without Pre-boot eXecution Environment (PXE).

Table 1259. Network Interface Control Settings

Variable Name : DellNetworkInterfaceControlSettingsUnique

Data Type : Integer

Possible Data Values unknown(1) enabled(2) enabledWithoutPXE(4)

Meaning of Data Value

Network interface state is unknown.

Network interface is enabled.

Network interface is enabled without PXE.

Table 1260. BIOS Setting Value Type

Variable Name : DellBIOSSettingValueType

Data Type : Integer

Possible Data Values integer(1) string(2) enumeration(3) orderedList(4)

Meaning of Data Value

Value type is integer.

Value type is string.

Value type is enumeration.

Value type is ordered list.

Server Administrator Group 285

Local Response Agent Group

The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA).

The LRA allows systems managers to predetermine how a system running the server administrator responds to a particular event type, such as the loss of redundancy in a specific component or the elevation of temperature in a chassis. Systems managers can configure the LRA to respond to an event type with a specific action. When the condition of the critical component worsens, the systems manager can escalate the response to make it more obvious to the operator.

For example, when a voltage probe on a monitored machine reaches a warning condition, the systems manager may want to notify the operator by causing the machine to beep. When the voltage probe reaches failure, the systems manager might want to have the system that has a failing component send a broadcast message to the management system and power off the troubled system.

LRA Group Tables

The following management information base (MIB) tables define LRA variable attributes:

LRA Global Settings Table

LRA Action Table

LRA Global Settings

The global settings table allows the systems manager to determine what LRA capabilities exist for a specific system that is running Server Administrator. Some machines may support all or some of the capabilities described in

DellLocalResponseAgentCapabilitiesUnique. The LRA Global Settings Table also defines thermal shutdown capabilities and settings. In the event that a temperature probe determines the temperature is at or over the failure limit, the systems manager can set an action to be taken automatically.

Table 1261. LRA Global Settings Table

Name

Object ID

Description

Syntax

Access lRAGlobalSettingsTable

1.3.6.1.4.1.674.10892.1.1500.10

Defines the LRA Global Settings Table.

SEQUENCE OF LRAGlobalSettingsTableEntry

Not accessible

Table 1262. LRA Global Settings Table Entry

Name

Object ID

Description

Syntax

Access

Index lRAGlobalSettingsTableEntry

1.3.6.1.4.1.674.10892.1.1500.10.1

Defines the LRA Global Settings Table entry.

LRAGlobalSettingsTableEntry

Not accessible lRAGlobalchassisIndex

Table 1263. LRA Global Chassis Index

Name

Object ID

Description

Syntax

Access lRAGlobalchassisIndex

1.3.6.1.4.1.674.10892.1.1500.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

286 Server Administrator Group

Table 1264. LRA Global State

Name

Object ID

Description

Syntax

Access lRAGlobalState

1.3.6.1.4.1.674.10892.1.1500.10.1.2

Defines the state of the LRA global settings.

DellStateSettings

Read-only

Table 1265. LRA Global Settings Disable Time-out Value

Name

Object ID

Description

Syntax

Access lRAGlobalSettingsDisableTimeoutValue

1.3.6.1.4.1.674.10892.1.1500.10.1.3

Defines the time-out duration countdown, in seconds, that the LRA global settings are disabled after a system shutdown and reboot.

DellUnsigned32BitRange

Read-only

Table 1266. LRA Global Settings Capabilities Unique

Name

Object ID

Description

Syntax

Access lRAGlobalSettingsCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1500.10.1.4

Defines the set of global capabilities that all local response agents may or may not allow to be set or reset.

DellLocalResponseAgentCapabilitiesUnique (

LRA Capabilities Definitions )

Read-only

Table 1267. LRA Global Thermal Shutdown Capabilities Unique

Name

Object ID

Description

Syntax

Access lRAGlobalThermalShutdownCapabilitiesUnique

1.3.6.1.4.1.674.10892.1.1500.10.1.5

Defines the set of thermal shutdown capabilities that are supported by the LRA.

DellLRAThermalShutdownCapabilitiesUnique

Read-only

Table 1268. LRA Global Thermal Shutdown State Settings Unique

Name

Object ID

Description

Syntax

Access lRAGlobalThermalShutdownStateSettingsUnique

1.3.6.1.4.1.674.10892.1.1500.10.1.6

Defines the set of thermal shutdown state and settings that the local response agent supports.

DellLRAThermalShutdownStateSettingsUnique

Read-only

LRA Action Table

The DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilities that are allowed for a particular system. The LRA Action Table that follows selects which of the system’s capabilities (global actions) are to be enabled.

Server Administrator Group 287

Table 1269. LRA Action Table

Name

Object ID

Description

Syntax

Access lRAActionTableTable

1.3.6.1.4.1.674.10892.1.1500.20

Defines the LRA Action Table.

SEQUENCE OF LRAActionTableTableEntry

Not accessible

Table 1270. LRA Action Table Entry

Name

Object ID

Description

Syntax

Access

Index lRAActionTableTableEntry

1.3.6.1.4.1.674.10892.1.1500.20.1

Defines the LRA Action Table entry.

LRAActionTableTableEntry

Not accessible lRAActionTablechassisIndex

, lRAActionTableActionNumberIndex

Table 1271. LRA Action Table Chassis Index

Name

Object ID

Description

Syntax

Access lRAActionTablechassisIndex

1.3.6.1.4.1.674.10892.1.1500.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1272. LRA Action Table Action Number Index

Name

Object ID

Description lRAActionTableActionNumberIndex

1.3.6.1.4.1.674.10892.1.1500.20.1.2

Defines the LRA action number index. The action number indexes are as follows:

● 160 — temperature failure action definition

● 168 — cooling device failure action definition

● 172 — voltage failure action definition

● 200 — temperature warning action definition

● 202 — voltage warning action definition

● 204 — cooling device warning action definition

● 206 — amperage failure action definition

● 208 — amperage warning action definition

● 210 — a power or cooling unit redundancy lost action definition

● 212 — a power or cooling unit redundancy degraded action definition

● 214 — power supply failed action definition

● 220 — chassis intrusion action definition

● 228 — memory device warning action definition

● 474 — memory device failure action definition

● 1006 — automatic system recovery (ASR) action definition

● 1353 — power supply warning action definition

● 1553 — log near full action definition

288 Server Administrator Group

Table 1272. LRA Action Table Action Number Index (continued)

Syntax

Access

● 1554 — log full action definition

● 1603 — processor warning action definition

● 1604 — processor failure action definition

● 1703 — battery warning action definition

● 1704 — battery failure action definition

DellUnsigned16BitRange

Read-only

Table 1273. LRA Action Table User Application Name

Name

Object ID

Description

Syntax

Access lRAActionTableUserApplicationName

1.3.6.1.4.1.674.10892.1.1500.20.1.3

When the execute application value is set, provides the following user-assignable LRA information:

● Name of the user application executable path

● File name to execute

DisplayString (SIZE (0..256)

Read-only

Table 1274. LRA Action Table Settings Unique

Name

Object ID

Description

Syntax

Access lRAActionTableSettingsUnique

1.3.6.1.4.1.674.10892.1.1500.20.1.4

Defines the LRA settings.

DellLocalResponseAgentSettingsUnique (

Local Response Agent Settings Unique

)

Read-only

Local Response Agent Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 1275. LRA Capabilities Definitions

Variable Name : DellLocalResponseAgentCapabilitiesUnique

Data Type : Integer

Possible Data Values speakerControlCapable(1) consoleAlertCapable(2)

Meaning of Data Value

The LRA can issue a speaker beep.

The LRA can alert the console.

broadcastMessageCapable(4) osShutDownCapable(8) rebootCapable(16) powerCycleCapable(32) powerOFFCapable(64) executeApplicationCapable(256) lraFullyCapable(383)

The LRA can broadcast a message.

The LRA can shut down the operating system.

The LRA can reboot the system.

The LRA is capable of a system power cycle.

The LRA can shut the system power off.

The LRA can execute a user mode application.

The LRA has all of the preceding capabilities.

Server Administrator Group 289

Table 1276. LRA Thermal Shutdown Capabilities Unique

Variable Name : DellLRAThermalShutdownCapabilitiesUnique

Data Type : Integer

Possible Data Values none(0)

Meaning of Data Value

The LRA has no thermal shutdown capabilities.

Unknown capabilities(1) enableCapable(2) warningCapable(4) enableOnWarningCapable(6) failureCapable(8) enableOnFailureCapable(10) enableOnWarningOrFailure Capable(14)

The LRA’s thermal shutdown capabilities are unknown.

The LRA can be disabled (offline, a binary 0 value) or enabled

(online, a binary 1 value).

The LRA can carry out chassis-determined action(s) when a warning condition is detected.

The LRA enables activation of chassisdetermined action(s) when a warning condition is detected.

The LRA can carry out chassis-determined action(s) when a failure condition is detected.

The LRA enables activation of chassisdetermined action(s) when a failure condition is detected.

The LRA enables activation of chassisdetermined action(s) when either a failure or a warning condition is detected.

Table 1277. Local Response Agent Settings Unique

Variable Name : DellLocalResponseAgentSettingsUnique

Data Type : Integer

Possible Data Values speakerControl(1) consoleAlert(2)

Meaning of Data Value

LRA is set to issue a speaker beep.

LRA is set to issue a console alert.

broadcastMessage(4) osShutDown(8) reboot(16)

LRA is set to issue a broadcast message.

LRA is set to issue an operating system shutdown.

LRA is set to issue a system reboot.

powerCycle(32) powerOFF(64) executeApplication(256) allLRASettingsUnique(383)

LRA is set to issue a system power cycle.

LRA is set to issue a system power off.

LRA is set to start a user mode application.

LRA is set to all LRA settings combinations.

Cost of Ownership Group

The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization.

Cost of Ownership Group Tables

The Cost of Ownership Group defines objects in the following MIB tables:

Cost of Ownership Table

COO Service Contract Table

COO Cost Event Log Table

290 Server Administrator Group

COO Warranty Table

COO Lease Information Table

COO Schedule Number Table

COO Options Table

COO Maintenance Table

COO Repair Table

COO Support Information Table

COO Trouble Ticket Table

Cost of Ownership Table

The following MIB object sets up the Cost of Ownership Table.

Table 1278. Cost of Ownership

Name

Object ID

Description

Syntax

Access cooTable

1.3.6.1.4.1.674.10892.1.1600.10

Defines the Cost of Ownership Table.

SEQUENCE OF CooTableEntry

Not accessible

Table 1279. Cost of Ownership Table Entry

Name

Object ID

Description

Syntax

Access

Index cooTableEntry

1.3.6.1.4.1.674.10892.1.1600.10.1

Defines the Cost of Ownership Table entry.

CooTableEntry

Not accessible coochassisIndex

Table 1280. COO Chassis Index

Name

Object ID

Description

Syntax

Access coochassisIndex

1.3.6.1.4.1.674.10892.1.1600.10.1.1

Defines the index (one-based) of this chassis.

CooTableEntry

Read-only

Table 1281. COO State

Name

Object ID

Description

Syntax

Access cooState

1.3.6.1.4.1.674.10892.1.1600.10.1.2

Defines the acquisition state of the system.

DellStateSettings

Read-only

Table 1282. COO Acquisition Purchase Cost

Name

Object ID cooAquisitionPurchaseCost

1.3.6.1.4.1.674.10892.1.1600.10.1.3

Server Administrator Group 291

Table 1282. COO Acquisition Purchase Cost (continued)

Description

Syntax

Access

Defines the purchase cost of the system.

DellUnsigned32BitRange

Read-only

Table 1283. COO Acquisition Waybill Number

Name

Object ID

Description

Syntax

Access cooAquisitionWayBillNumber

1.3.6.1.4.1.674.10892.1.1600.10.1.4

Defines the waybill number of the system.

DellUnsigned32BitRange

Read-only

Table 1284. COO Acquisition Install Date Name

Name

Object ID

Description

Syntax

Access cooAquisitionInstallDateName

1.3.6.1.4.1.674.10892.1.1600.10.1.5

Defines the installation date and time for the system.

DellDateName

Read-only

Table 1285. COO Acquisition Purchase Order

Name

Object ID

Description

Syntax

Access cooAquisitionPurchaseOrder

1.3.6.1.4.1.674.10892.1.1600.10.1.6

Defines the purchase order number of the system.

DellUnsigned32BitRange

Read-only

Table 1286. COO Acquisition Purchase Date Name

Name

Object ID

Description

Syntax

Access cooAquisitionPurchaseDateName

1.3.6.1.4.1.674.10892.1.1600.10.1.7

Defines the purchase date and time of the system.

DellDateName

Read-only

Table 1287. COO Acquisition Signing Authority Name

Name

Object ID

Description

Syntax

Access cooAquisitionSigningAuthorityName

1.3.6.1.4.1.674.10892.1.1600.10.1.8

Defines the name of the authorized person who signs for the system.

DellCostofOwnershipString

Read-only

Table 1288. COO Original Machine Configuration Expensed

Name

Object ID cooOriginalMachineConfigurationExpensed

1.3.6.1.4.1.674.10892.1.1600.10.1.9

292 Server Administrator Group

Table 1288. COO Original Machine Configuration Expensed (continued)

Description

Syntax

Access

Specifies whether the purchase of this system was expensed.

DellBoolean

Read-only

Table 1289. COO Original Machine Configuration Vendor Name

Name

Object ID

Description

Syntax

Access cooOriginalMachineConfigurationVendorName

1.3.6.1.4.1.674.10892.1.1600.10.1.10

Defines the vendor name of the system.

DellCostofOwnershipString

Read-only

Table 1290. COO Cost Center Information Vendor Name

Name

Object ID

Description

Syntax

Access cooCostCenterInformationVendorName

1.3.6.1.4.1.674.10892.1.1600.10.1.11

Defines the cost center name of the system.

DellCostofOwnershipString

Read-only

Table 1291. COO User Information User Name

Name

Object ID

Description

Syntax

Access cooUserInformationUserName

1.3.6.1.4.1.674.10892.1.1600.10.1.12

Defines the name of the user for this system.

DellCostofOwnershipString

Read-only

Table 1292. COO Extended Warranty Start Date Name

Name

Object ID

Description

Syntax

Access cooExtendedWarrantyStartDateName

1.3.6.1.4.1.674.10892.1.1600.10.1.13

Defines the extended warranty start date for this system.

DellDateName

Read-only

Table 1293. COO Extended Warranty End Date Name

Name

Object ID

Description

Syntax

Access cooExtendedWarrantyEndDateName

1.3.6.1.4.1.674.10892.1.1600.10.1.14

Defines the extended warranty end date for this system.

DellDateName

Read-only

Table 1294. COO Extended Warranty Cost

Name

Object ID cooExtendedWarrantyCost

1.3.6.1.4.1.674.10892.1.1600.10.1.15

Server Administrator Group 293

Table 1294. COO Extended Warranty Cost (continued)

Description

Syntax

Access

Defines the extended warranty cost date for this system.

DellUnsigned32BitRange

Read-only

Table 1295. COO Extended Warranty Provider Name

Name

Object ID

Description

Syntax

Access cooExtendedWarrantyProviderName

1.3.6.1.4.1.674.10892.1.1600.10.1.16

Defines the name of the extended warranty provider for this system.

DellCostofOwnershipString

Read-only

Table 1296. COO Ownership Code

Name

Object ID

Description

Syntax

Access cooOwnershipCode

1.3.6.1.4.1.674.10892.1.1600.10.1.17

Defines the ownership code for this system.

DellCooOwnershipCodes (See

COO Ownership Codes

)

Read-only

Table 1297. COO Corporate Owner Name

Name

Object ID

Description

Syntax

Access cooCorporateOwnerName

1.3.6.1.4.1.674.10892.1.1600.10.1.18

Defines the name of the corporation that owns this system.

DellCostofOwnershipString

Read-only

Table 1298. COO Hazardous Waste Code Name

Name

Object ID

Description

Syntax

Access cooHazardousWasteCodeName

1.3.6.1.4.1.674.10892.1.1600.10.1.19

Defines the hazardous waste code for this system.

DellCostofOwnershipString

Read-only

Table 1299. COO Deployment Date Length

Name

Object ID

Description

Syntax

Access cooDeploymentDateLength

1.3.6.1.4.1.674.10892.1.1600.10.1.20

Defines the deployment time for this system.

DellUnsigned32BitRange

Read-only

Table 1300. COO Deployment Duration Type

Name

Object ID cooDeploymentDurationType

1.3.6.1.4.1.674.10892.1.1600.10.1.21

294 Server Administrator Group

Table 1300. COO Deployment Duration Type (continued)

Description

Syntax

Access

Defines the deployment time units for this system.

DellCooHourDayDurationType (See

COO Hour Day Duration Type

)

Read-only

Table 1301. COO Training Name

Name

Object ID

Description

Syntax

Access cooTrainingName

1.3.6.1.4.1.674.10892.1.1600.10.1.22

Defines the training that the user has for this system.

DellCostofOwnershipString

Read-only

Table 1302. COO Outsourcing Problem Description Name

Name

Object ID

Description

Syntax

Access cooOutsourcingProblemDescriptionName

1.3.6.1.4.1.674.10892.1.1600.10.1.23

Defines a problem encountered with the outsourcing service provider.

DellCostofOwnershipString

Read-only

Table 1303. COO Outsourcing Service Fee Name

Name

Object ID

Description

Syntax

Access cooOutsourcingServiceFeeName

1.3.6.1.4.1.674.10892.1.1600.10.1.24

Defines amount that the outsourcing vendor charges for service.

DellCostofOwnershipString

Read-only

Table 1304. COO Outsourcing Signing Authority Name

Name

Object ID

Description

Syntax

Access cooOutsourcingSigningAuthorityName

1.3.6.1.4.1.674.10892.1.1600.10.1.25

Defines the name of the person who can sign the authorization for service.

DellCostofOwnershipString

Read-only

Table 1305. COO Outsourcing Provider Fee Name

Name

Object ID

Description

Syntax

Access cooOutsourcingProviderFeeName

1.3.6.1.4.1.674.10892.1.1600.10.1.26

Defines any additional outsourcing charge for service.

DellCostofOwnershipString

Read-only

Table 1306. COO Outsourcing Provider Service Level Name

Name

Object ID cooOutsourcingProviderServiceLevelName

1.3.6.1.4.1.674.10892.1.1600.10.1.27

Server Administrator Group 295

Table 1306. COO Outsourcing Provider Service Level Name (continued)

Description

Syntax

Access

Defines the service level agreement for the system.

DellCostofOwnershipString

Read-only

Table 1307. COO Insurance Company Name

Name

Object ID

Description

Syntax

Access cooInsuranceCompanyName

1.3.6.1.4.1.674.10892.1.1600.10.1.28

Defines the name of the company that insures this system.

DellCostofOwnershipString

Read-only

Table 1308. COO Box Asset Tag Name

Name

Object ID

Description

Syntax

Access cooBoxAssetTagName

1.3.6.1.4.1.674.10892.1.1600.10.1.29

Defines the name of the asset tag.

DellCostofOwnershipString

Read-only

Table 1309. COO Box System Name

Name

Object ID

Description

Syntax

Access cooBoxSystemName

1.3.6.1.4.1.674.10892.1.1600.10.1.30

Defines the name of the system.

DellCostofOwnershipString

Read-only

Table 1310. COO Box Central Processing Unit (CPU) Serial Number Name

Name

Object ID

Description

Syntax

Access cooBoxCPUSerialNumberName

1.3.6.1.4.1.674.10892.1.1600.10.1.31

Defines the name of the CPU serial number for the system.

DellCostofOwnershipString

Read-only

Table 1311. COO Operating System Upgrade Type Name

Name

Object ID

Description

Syntax

Access cooOperatingSystemUpgradeTypeName

1.3.6.1.4.1.674.10892.1.1600.10.1.32

Defines the name of the operating system on this system.

DellCostofOwnershipString

Read-only

Table 1312. COO Operating System Upgrade Patch Level Name

Name

Object ID cooOperatingSystemUpgradePatchLevelName

1.3.6.1.4.1.674.10892.1.1600.10.1.33

296 Server Administrator Group

Table 1312. COO Operating System Upgrade Patch Level Name (continued)

Description

Syntax

Access

Defines the name of the operating system patch level for this system.

DellCostofOwnershipString

Read-only

Table 1313. COO Operating System Upgrade Date

Name

Object ID

Description

Syntax

Access cooOperatingSystemUpgradeDate

1.3.6.1.4.1.674.10892.1.1600.10.1.34

Defines the upgrade file date for this operating system.

DellCostofOwnershipString

Read-only

Table 1314. COO Depreciation Duration

Name

Object ID

Description

Syntax

Access cooDepreciationDuration

1.3.6.1.4.1.674.10892.1.1600.10.1.35

Defines the length of depreciation for this system.

DellUnsigned32BitRange

Read-only

Table 1315. COO Depreciation Duration Type

Name

Object ID

Description

Syntax

Access cooDepreciationDurationType

1.3.6.1.4.1.674.10892.1.1600.10.1.36

Defines the unit of time for the depreciation of this system.

DellCooMonthYearDurationType

Read-only

Table 1316. COO Depreciation Percentage

Name

Object ID

Description

Syntax

Access cooDepreciationPercentage

1.3.6.1.4.1.674.10892.1.1600.10.1.37

Defines the percentage of depreciation for this system.

DellUnsigned32BitRange

Read-only

Table 1317. COO Depreciation Method Name

Name

Object ID

Description

Syntax

Access cooDepreciationMethodName

1.3.6.1.4.1.674.10892.1.1600.10.1.38

Defines the name of the depreciation method for this system.

DellCostofOwnershipString

Read-only

Table 1318. COO Registration Is Registered

Name

Object ID cooRegistrationIsRegistered

1.3.6.1.4.1.674.10892.1.1600.10.1.39

Server Administrator Group 297

Table 1318. COO Registration Is Registered (continued)

Description

Syntax

Access

Specifies whether this system is registered or not.

DellBoolean

Read-only

COO Service Contract Table

The service contract table provides MIB objects that help you track the name, vendor, and type of service contract you have for your system.

Table 1319. COO Service Contract Table

Name

Object ID

Description

Syntax

Access cooServiceContractTable

1.3.6.1.4.1.674.10892.1.1600.20

Defines the COO Service Contract Table.

SEQUENCE OF CooServiceContractTableEntry

Not accessible

Table 1320. COO Service Contract Table Entry

Name

Object ID

Description

Syntax

Access

Index cooServiceContractTableEntry

1.3.6.1.4.1.674.10892.1.1600.20.1

Defines the COO Service Contract Table entry.

CooServiceContractTableEntry

Not accessible cooServiceContractchassisIndex

, cooServiceContractIndex

Table 1321. COO Service Contract Chassis Index

Name

Object ID

Description

Syntax

Access cooServiceContractchassisIndex

1.3.6.1.4.1.674.10892.1.1600.20.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1322. COO Service Contract Index

Name

Object ID

Description

Syntax

Access cooServiceContractIndex

1.3.6.1.4.1.674.10892.1.1600.20.1.2

Defines the index (one-based) of this service contract.

DellObjectRange

Read-only

298 Server Administrator Group

Table 1323. COO Service Contract State

Name

Object ID

Description

Syntax

Access cooServiceContractState

1.3.6.1.4.1.674.10892.1.1600.20.1.3

Defines the status of the service contract for this system.

DellStateSettings

Read-only

Table 1324. COO Service Contract Was Renewed

Name

Object ID

Description

Syntax

Access cooServiceContractWasRenewed

1.3.6.1.4.1.674.10892.1.1600.20.1.4

Specifies whether the service contract for this system was renewed.

DellBoolean

Read-only

Table 1325. COO Service Contract Type Name

Name

Object ID

Description

Syntax

Access cooServiceContractTypeName

1.3.6.1.4.1.674.10892.1.1600.20.1.5

Defines the name of the service contract type for this system.

DellCostofOwnershipString

Read-only

Table 1326. COO Service Contract Vendor Name

Name

Object ID

Description

Syntax

Access cooServiceContractVendorName

1.3.6.1.4.1.674.10892.1.1600.20.1.6

Defines the name of the service contract provider for this system.

DellCostofOwnershipString

Read-only

COO Cost Event Log Table

The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of events that are logged for a particular system.

Table 1327. COO Cost Event Log Table

Name

Object ID

Description

Syntax

Access cooCostEventLogTable

1.3.6.1.4.1.674.10892.1.1600.30

Defines the COO Cost Event Log Table.

SEQUENCE OF COO CostEventLogTableEntry

Not accessible

Table 1328. COO Cost Event Log Table Entry

Name

Object ID cooCostEventLogTableEntry

1.3.6.1.4.1.674.10892.1.1600.30.1

Server Administrator Group 299

Table 1328. COO Cost Event Log Table Entry (continued)

Description

Syntax

Access

Index

Defines the COO Cost Event Log Table entry.

cooCostEventLogTableEntry

Not accessible cooCostEventLogchassisIndex

, cooCostEventLogIndex

Table 1329. COO Cost Event Log Chassis Index

Name

Object ID

Description

Syntax

Access cooCostEventLogchassisIndex

1.3.6.1.4.1.674.10892.1.1600.30.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1330. COO Cost Event Log Index

Name

Object ID

Description

Syntax

Access cooCostEventLogIndex

1.3.6.1.4.1.674.10892.1.1600.30.1.2

Defines the index (one-based) of the cost event log.

DellObjectRange

Read-only

Table 1331. COO Cost Event Log State

Name

Object ID

Description

Syntax

Access cooCostEventLogState

1.3.6.1.4.1.674.10892.1.1600.30.1.3

Defines the cost event log state of this system.

DellStateSettings

Read-only

Table 1332. COO Cost Event Log Duration

Name

Object ID

Description

Syntax

Access cooCostEventLogDuration

1.3.6.1.4.1.674.10892.1.1600.30.1.4

Defines the duration of the event for this system.

DellUnsigned32BitRange

Read-only

Table 1333. COO Cost Event Log Duration Type

Name

Object ID

Description

Syntax cooCostEventLogDurationType

1.3.6.1.4.1.674.10892.1.1600.30.1.5

Defines the duration type of the event for this system.

DellCOOHourDayDurationType (See

COO Hour Day Duration Type

)

300 Server Administrator Group

Table 1333. COO Cost Event Log Duration Type (continued)

Access Read-only

Table 1334. COO Cost Event Log Description Name

Name

Object ID

Description

Syntax

Access cooCostEventLogDescriptionName

1.3.6.1.4.1.674.10892.1.1600.30.1.6

Defines the name of the event description.

DellCostofOwnershipString

Read-only

COO Warranty Table

The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system.

Table 1335. COO Warranty Table

Name

Object ID

Description

Syntax

Access cooWarrantyTable

1.3.6.1.4.1.674.10892.1.1600.40

Defines the COO Warranty Table.

SEQUENCE OF CooWarrantyTableEntry

Not accessible

Table 1336. COO Warranty Table Entry

Name

Object ID

Description

Syntax

Access

Index cooWarrantyTableEntry

1.3.6.1.4.1.674.10892.1.1600.40.1

Defines the COO Warranty Table entry.

CooWarrantyTableEntry

Not accessible cooWarrantychassisIndex

, cooWarrantyIndex

Table 1337. COO Warranty Chassis Index

Name

Object ID

Description

Syntax

Access cooWarrantychassisIndex

1.3.6.1.4.1.674.10892.1.1600.40.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1338. COO Warranty Index

Name

Object ID

Description cooWarrantyIndex

1.3.6.1.4.1.674.10892.1.1600.40.1.2

Defines the index of the warranty for this system.

Server Administrator Group 301

Table 1338. COO Warranty Index (continued)

Syntax

Access

DellObjectRange

Read-only

Table 1339. COO Warranty State

Name

Object ID

Description

Syntax

Access cooWarrantyState

1.3.6.1.4.1.674.10892.1.1600.40.1.3

Defines the state of the warranty for this system.

DellStateSettings

Read-only

Table 1340. COO Warranty Duration

Name

Object ID

Description

Syntax

Access cooWarrantyDuration

1.3.6.1.4.1.674.10892.1.1600.40.1.4

Defines the duration of the warranty.

DellUnsigned32BitRange

Read-only

Table 1341. COO Warranty Duration Type

Name

Object ID

Description

Syntax

Access cooWarrantyDurationType

1.3.6.1.4.1.674.10892.1.1600.40.1.5

Defines the warranty duration type for the system.

DellCOODayMonthDurationType

Read-only

Table 1342. COO Warranty End Date Name

Name

Object ID

Description

Syntax

Access cooWarrantyEndDateName

1.3.6.1.4.1.674.10892.1.1600.40.1.6

Defines the warranty end date for this system.

DellDateName

Read-only

Table 1343. COO Warranty Cost

Name cooWarrantyCost

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1600.40.1.7

Defines the cost of the warranty for this system.

DellUnsigned32BitRange

Read-only

COO Lease Information Table

The COO lease information MIB objects enable you to track information about your lessor, lease duration, and lease type for each system.

302 Server Administrator Group

Table 1344. COO Lease Information Table

Name

Object ID

Description

Syntax

Access cooLeaseInformationTable

1.3.6.1.4.1.674.10892.1.1600.50

Defines the COO Lease Information Table.

SEQUENCE OF CooLeaseInformationTableEntry

Not accessible

Table 1345. COO Lease Information Table Entry

Name

Object ID

Description

Syntax

Access

Index cooLeaseInformationTableEntry

1.3.6.1.4.1.674.10892.1.1600.50.1

Defines the COO Lease Information Table entry.

CooLeaseInformationTableEntry

Not accessible cooLeaseInformationchassisIndex

, cooLeaseInformationIndex

Table 1346. COO Lease Information Chassis Index

Name

Object ID

Description

Syntax

Access cooLeaseInformationchassisIndex

1.3.6.1.4.1.674.10892.1.1600.50.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1347. COO Lease Information Index

Name

Object ID

Description

Syntax

Access cooLeaseInformationIndex

1.3.6.1.4.1.674.10892.1.1600.50.1.2

Defines the index of the lease information for this system.

DellObjectRange

Read-only

Table 1348. COO Lease Information State

Name

Object ID

Description

Syntax

Access cooLeaseInformationState

1.3.6.1.4.1.674.10892.1.1600.50.1.3

Defines the lease information state for this system.

DellStateSettings

Read-only

Table 1349. COO Lease Information Multiple Schedules

Name

Object ID cooLeaseInformationMultipleSchedules

1.3.6.1.4.1.674.10892.1.1600.50.1.4

Server Administrator Group 303

Table 1349. COO Lease Information Multiple Schedules (continued)

Description

Syntax

Access

Defines whether there are multiple schedules for this lease.

DellBoolean

Read-only

Table 1350. COO Lease Information Buyout Amount

Name

Object ID

Description

Syntax

Access cooLeaseInformationBuyOutAmount

1.3.6.1.4.1.674.10892.1.1600.50.1.5

Defines the balance purchase price for this system.

DellUnsigned32BitRange

Read-only

Table 1351. COO Lease Information Lease Rate Factor

Name

Object ID

Description

Syntax

Access cooLeaseInformationLeaseRateFactor

1.3.6.1.4.1.674.10892.1.1600.50.1.6

Defines the rate factor for the lease on this system.

DellUnsigned32BitRange

Read-only

Table 1352. COO Lease Information End Date Name

Name

Object ID

Description

Syntax

Access cooLeaseInformationEndDateName

1.3.6.1.4.1.674.10892.1.1600.50.1.7

Defines the end date for the lease on this system.

DellDateName

Read-only

Table 1353. COO Lease Information Fair Market Value

Name

Object ID

Description

Syntax

Access cooLeaseInformationFairMarketValue

1.3.6.1.4.1.674.10892.1.1600.50.1.8

Defines the fair market value of this system.

DellUnsigned32BitRange

Read-only

Table 1354. COO Lease Information Lessor Name

Name

Object ID

Description

Syntax

Access cooLeaseInformationLessorName

1.3.6.1.4.1.674.10892.1.1600.50.1.9

Defines the name of the lessor of this system.

DellCostofOwnershipString

Read-only

304 Server Administrator Group

COO Schedule Number Table

Table 1355. COO Schedule Number Table

Name

Object ID

Description

Syntax

Access cooScheduleNumberTable

1.3.6.1.4.1.674.10892.1.1600.60

Defines the COO Schedule Number Information Table.

SEQUENCE OF CooScheduleNumberTableEntry

Not accessible

Table 1356. COO Schedule Number Table Entry

Name

Object ID

Description

Syntax

Access

Index cooScheduleNumberTableEntry

1.3.6.1.4.1.674.10892.1.1600.60.1

Defines the COO Schedule Number Information Table entry.

CooScheduleNumberTableEntry

Not accessible cooScheduleNumberchassisIndex

, cooScheduleNumberIndex

Table 1357. COO Schedule Number Chassis Index

Name

Object ID

Description

Syntax

Access cooScheduleNumberchassisIndex

1.3.6.1.4.1.674.10892.1.1600.60.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1358. COO Schedule Number Index

Name

Object ID

Description

Syntax

Access cooScheduleNumberIndex

1.3.6.1.4.1.674.10892.1.1600.60.1.2

Defines the index of the schedule number information.

DellObjectRange

Read-only

Table 1359. COO Schedule Number State

Name

Object ID

Description

Syntax

Access cooScheduleNumberState

1.3.6.1.4.1.674.10892.1.1600.60.1.3

Defines the schedule number information state of this system.

DellStateSettings

Read-only

Server Administrator Group 305

Table 1360. COO Schedule Number Lease Information Index Reference

Name

Object ID

Description

Syntax

Access cooScheduleNumberLeaseInformationIndexReference

1.3.6.1.4.1.674.10892.1.1600.60.1.4

Defines the lease information index number to reference the schedule number.

DellUnsigned32BitRange

Read-only

Table 1361. COO Schedule Number Description Name

Name

Object ID

Description

Syntax

Access cooScheduleNumberDescriptionName

1.3.6.1.4.1.674.10892.1.1600.60.1.5

Describes the schedule number information.

DellCostofOwnershipString

Read-only

COO Options Table

Table 1362. COO Options Table

Name

Object ID

Description

Syntax

Access cooOptionsTable

1.3.6.1.4.1.674.10892.1.1600.70

Defines the COO Options Table.

SEQUENCE OF CooOptionsTableEntry

Not accessible

Table 1363. COO Options Table Entry

Name cooOptionsTableEntry

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.1600.70.1

Defines the COO Options Table entry.

CooOptionsTableEntry

Not accessible cooOptionschassisIndex

, cooOptionsIndex

Table 1364. COO Options Chassis Index

Name

Object ID

Description

Syntax

Access cooOptionschassisIndex

1.3.6.1.4.1.674.10892.1.1600.70.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

306 Server Administrator Group

Table 1365. COO Options Index

Name

Object ID

Description

Syntax

Access cooOptionsIndex

1.3.6.1.4.1.674.10892.1.1600.70.1.2

Defines the index (one-based) of the option information for this system.

DellObjectRange

Read-only

Table 1366. COO Options State

Name

Object ID

Description

Syntax

Access cooOptionsState

1.3.6.1.4.1.674.10892.1.1600.70.1.3

Defines the option information state for this system.

DellStateSettings

Read-only

Table 1367. COO Options Lease Information Index Reference

Name

Object ID

Description

Syntax

Access cooOptionsLeaseInformationIndexReference

1.3.6.1.4.1.674.10892.1.1600.70.1.4

Defines the lease information index of the option information for this system.

DellUnsigned32BitRange

Read-only

Table 1368. COO Options Description Name

Name

Object ID

Description

Syntax

Access cooOptionsDescriptionName

1.3.6.1.4.1.674.10892.1.1600.70.1.5

Defines the option information description name.

DellCostofOwnershipString

Read-only

COO Maintenance Table

Table 1369. COO Maintenance Table

Name

Object ID

Description

Syntax

Access cooMaintenanceTable

1.3.6.1.4.1.674.10892.1.1600.80

Defines the COO Maintenance Table.

SEQUENCE OF CooMaintenanceTableEntry

Not accessible

Table 1370. COO Maintenance Table Entry

Name

Object ID

Description

Syntax cooMaintenanceTableEntry

1.3.6.1.4.1.674.10892.1.1600.80.1

Defines the COO Maintenance Table entry.

CooMaintenanceTableEntry

Server Administrator Group 307

Table 1370. COO Maintenance Table Entry (continued)

Access

Index

Not accessible cooMaintenancechassisIndex

, cooMaintenanceIndex

Table 1371. COO Maintenance Chassis Index

Name

Object ID

Description

Syntax

Access cooMaintenancechassisIndex

1.3.6.1.4.1.674.10892.1.1600.80.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1372. COO Maintenance Index

Name

Object ID

Description

Syntax

Access cooMaintenanceIndex

1.3.6.1.4.1.674.10892.1.1600.80.1.2

Defines the index of this system’s maintenance information.

DellObjectRange

Read-only

Table 1373. COO Maintenance State

Name

Object ID

Description

Syntax

Access cooMaintenanceState

1.3.6.1.4.1.674.10892.1.1600.80.1.3

Defines the state of this system’s maintenance information.

DellStateSettings

Read-only

Table 1374. COO Maintenance Start Date Name

Name

Object ID

Description

Syntax

Access cooMaintenanceStartDateName

1.3.6.1.4.1.674.10892.1.1600.80.1.4

Defines the start date for maintenance on this system.

DellDateName

Read-only

Table 1375. COO Maintenance End Date Name

Name cooMaintenanceEndDateName

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1600.80.1.5

Defines the end date for maintenance on this system.

DellDateName

Read-only

308 Server Administrator Group

Table 1376. COO Maintenance Provider Name

Name

Object ID

Description

Syntax

Access cooMaintenanceProviderName

1.3.6.1.4.1.674.10892.1.1600.80.1.6

Defines the maintenance provider’s name.

DellStateSettings

Read-only

Table 1377. COO Maintenance Restrictions Name

Name

Object ID

Description

Syntax

Access cooMaintenanceRestrictionsName

1.3.6.1.4.1.674.10892.1.1600.80.1.7

Defines the maintenance agreement restrictions.

DellCostofOwnershipString

Read-only

COO Repair Table

Table 1378. COO Repair Table

Name

Object ID

Description

Syntax

Access cooRepairTable

1.3.6.1.4.1.674.10892.1.1600.90

Defines the COO Repair Table.

SEQUENCE OF CooRepairTableEntry

Not accessible

Table 1379. COO Repair Table Entry

Name cooRepairTableEntry

Object ID

Description

Syntax

Access

Index

1.3.6.1.4.1.674.10892.1.1600.90.1

Defines the COO Repair Table entry.

CooRepairTableEntry

Not accessible cooRepairchassisIndex

, cooRepairIndex

Table 1380. COO Repair Chassis Index

Name

Object ID

Description

Syntax

Access cooRepairchassisIndex

1.3.6.1.4.1.674.10892.1.1600.90.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Server Administrator Group 309

Table 1381. COO Repair Index

Name

Object ID

Description

Syntax

Access cooRepairIndex

1.3.6.1.4.1.674.10892.1.1600.90.1.2

Defines the index (one-based) of the repair information for this system.

DellObjectRange

Read-only

Table 1382. COO Repair State

Name

Object ID

Description

Syntax

Access cooRepairState

1.3.6.1.4.1.674.10892.1.1600.90.1.3

Defines the state of the repair information for this system.

DellStateSettings

Read-only

Table 1383. COO Repair Counter

Name

Object ID

Description

Syntax

Access cooRepairCounter

1.3.6.1.4.1.674.10892.1.1600.90.1.4

Defines the number of repairs that this system has undergone.

DellCostofOwnershipString

Read-only

Table 1384. COO Repair Vendor Name

Name

Object ID

Description

Syntax

Access cooRepairVendorName

1.3.6.1.4.1.674.10892.1.1600.90.1.5

Defines the name of the vendor that repairs this system.

DellStateSettings

Read-only

COO Support Information Table

Table 1385. COO Support Information Table

Name

Object ID

Description

Syntax

Access cooSupportInformationTable

1.3.6.1.4.1.674.10892.1.1600.100

Defines the COO Support Information Table.

SEQUENCE OF cooSupportInformationTableEntry

Not accessible

Table 1386. COO Support Information Table Entry

Name

Object ID

Description

Syntax cooSupportInformationTableEntry

1.3.6.1.4.1.674.10892.1.1600.100.1

Defines the COO Support Information Table entry.

cooSupportInformationTableEntry

310 Server Administrator Group

Table 1386. COO Support Information Table Entry (continued)

Access

Index

Not accessible cooSupportInformationchassisIndex

,

cooSupportInformationIndex

Table 1387. COO Support Information Chassis Index

Name

Object ID

Description

Syntax

Access cooSupportInformationchassisIndex

1.3.6.1.4.1.674.10892.1.1600.100.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1388. COO Support Information Index

Name

Object ID

Description

Syntax

Access cooSupportInformationIndex

1.3.6.1.4.1.674.10892.1.1600.100.1.2

Defines the index (one-based) for this system’s support information.

DellObjectRange

Read-only

Table 1389. COO Support Information State

Name

Object ID

Description

Syntax

Access cooSupportInformationState

1.3.6.1.4.1.674.10892.1.1600.100.1.3

Defines the support information state for this system.

DellStateSettings

Read-only

Table 1390. COO Support Information Is Outsourced

Name

Object ID

Description

Syntax

Access cooSupportInformationIsOutsourced

1.3.6.1.4.1.674.10892.1.1600.100.1.4

Specifies whether the support for this system is outsourced or not.

DellBoolean

Read-only

Table 1391. COO Support Information Type

Name cooSupportInformationType

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1600.100.1.5

Defines the type of component, system, or network problem that occurred.

DellUnsigned32BitRange

Read-only

Server Administrator Group 311

Table 1392. COO Support Information Help Desk Name

Name

Object ID

Description

Syntax

Access cooSupportInformationHelpDeskName

1.3.6.1.4.1.674.10892.1.1600.100.1.6

Defines the help desk information provided.

DellCostofOwnershipString

Read-only

Table 1393. COO Support Information Fix Type Name

Name

Object ID

Description

Syntax

Access cooSupportInformationFixTypeName

1.3.6.1.4.1.674.10892.1.1600.100.1.7

Defines the method used to fix the problem.

DellCostofOwnershipString

Read-only

COO Trouble Ticket Table

The MIB objects in the Trouble Ticket Table allows you to track details of any trouble tickets that you open for your system.

Table 1394. COO Trouble Ticket Table

Name

Object ID

Description

Syntax

Access cooTroubleTicketTable

1.3.6.1.4.1.674.10892.1.1600.110

Defines the COO Trouble Ticket Table.

SEQUENCE OF cooTroubleTicketTableEntry

Not accessible

Table 1395. COO Trouble Ticket Table Entry

Name

Object ID

Description

Syntax

Access

Index cooTroubleTicketTableEntry

1.3.6.1.4.1.674.10892.1.1600.110.1

Defines the COO Trouble Ticket Table entry.

cooTroubleTicketTableEntry

Not accessible cooTroubleTicketchassisIndex

, cooTroubleTicketIndex

Table 1396. COO Trouble Ticket Chassis Index

Name

Object ID

Description

Syntax

Access cooTroubleTicketchassisIndex

1.3.6.1.4.1.674.10892.1.1600.110.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

312 Server Administrator Group

Table 1397. COO Trouble Ticket Index

Name

Object ID

Description

Syntax

Access cooTroubleTicketIndex

1.3.6.1.4.1.674.10892.1.1600.110.1.2

Defines the index (one-based) of the system’s trouble ticket information.

DellObjectRange

Read-only

Table 1398. COO Trouble Ticket State

Name

Object ID

Description

Syntax

Access cooTroubleTicketState

1.3.6.1.4.1.674.10892.1.1600.110.1.3

Defines the trouble ticket information state for this system.

DellStateSettings

Read-only

Table 1399. COO Trouble Ticket Support Information Index Reference

Name

Object ID

Description

Syntax

Access cooTroubleTicketSupportInformationIndexReference

1.3.6.1.4.1.674.10892.1.1600.110.1.4

Defines the support information index that references the trouble ticket.

DellUnsigned32BitRange

Read-only

Table 1400. COO Trouble Ticket Number Name

Name

Object ID

Description

Syntax

Access cooTroubleTicketNumberName

1.3.6.1.4.1.674.10892.1.1600.110.1.5

Defines the trouble ticket number for this system.

DellCostofOwnershipString

Read-only

Cost of Ownership Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 1401. COO Ownership Codes

Variable Name: DellCooOwnershipCodes

Data Type: Integer

Possible Data Values other(1) unknown(2) owned(3) leased(4) rented(5) offOfLease(6)

Meaning of Data Value

The ownership code is not one of following:

The ownership code is unknown.

The ownership code is owned.

The ownership code is leased.

The ownership code is rented.

The ownership code is off of lease.

Server Administrator Group 313

Table 1401. COO Ownership Codes (continued) transfer(7) The ownership code is transfer.

Table 1402. COO Hour Day Duration Type

Variable Name: DellCooHourDayDurationType

Data Type: Integer

Possible Data Values unknown(1) hours(2) days(3)

Meaning of Data Value

Duration time type is unknown.

Duration time type is in hours.

Duration time type is in days.

Table 1403. COO Day Month Duration Type

Variable Name: DellCooDayMonthDurationType

Data Type: Integer

Possible Data Values unknown(1) days(3) months(4)

Meaning of Data Value

Duration time type is unknown.

Duration time type is in days.

Duration time type is in months.

Table 1404. COO Month Year Duration Type

Variable Name: DellCooMonthYearDurationType

Data Type: Integer

Possible Data Values unknown(1) months(4) years(5)

Meaning of Data Value

Duration time type is unknown.

Duration time type is in months.

Duration time type is in years.

Cluster Group

Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using failover clusters, in which resources can automatically move between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems. Simpler management is achieved by using virtual servers, as opposed to managing each individual computer system.

Cluster Group

The Cluster Group defines attributes such as the number of systems in the cluster, capabilities of the cluster, type of cluster, and name of the cluster.

Cluster Table

The following table defines the attributes of the cluster.

314 Server Administrator Group

Table 1405. Cluster Table

Name

Object ID

Description

Syntax

Access clusterTable

1.3.6.1.4.1.674.10892.1.1800.10

Defines the Cluster Table.

SEQUENCE OF ClusterTableEntry

Not accessible

Table 1406. Cluster Table Entry

Name

Object ID

Description

Syntax

Access

Index clusterTableEntry

1.3.6.1.4.1.674.10892.1.1800.10.1

Defines the Cluster Table entry.

ClusterTableEntry

Not accessible clusterChassisIndex

, clusterIndex

Table 1407. Cluster Chassis Index

Name

Object ID

Description

Syntax

Access clusterChassisIndex

1.3.6.1.4.1.674.10892.1.1800.10.1.1

Defines the index (one-based) of this chassis.

DellObjectRange

Read-only

Table 1408. Cluster Index

Name

Object ID

Description

Syntax

Access clusterIndex

1.3.6.1.4.1.674.10892.1.1800.10.1.2

Defines the index (one-based) of the cluster.

DellObjectRange

Read-only

Table 1409. Cluster State Capabilities

Name

Object ID

Description

Syntax

Access clusterStateCapabilities

1.3.6.1.4.1.674.10892.1.1800.10.1.3

Defines the state capabilities of the cluster.

DellStateCapabilities

Read-only

Table 1410. Cluster State Settings

Name

Object ID clusterStateSettings

1.3.6.1.4.1.674.10892.1.1800.10.1.4

Server Administrator Group 315

Table 1410. Cluster State Settings (continued)

Description

Syntax

Access

Defines the state settings of the cluster.

DellStateSettings

Read-only

Table 1411. Cluster Status

Name

Object ID

Description

Syntax

Access clusterStatus

1.3.6.1.4.1.674.10892.1.1800.10.1.5

Defines the status of the cluster.

DellStatus

Read-only

Table 1412. Cluster Type

Name

Object ID

Description

Syntax

Access clusterType

1.3.6.1.4.1.674.10892.1.1800.10.1.6

Defines the type of the cluster.

DellClusterType

Read-only

Table 1413. Cluster Type Description Name

Name

Object ID

Description

Syntax

Access clusterTypeDescriptionName

1.3.6.1.4.1.674.10892.1.1800.10.1.7

Defines the description name for the type of the cluster.

DellString

Read-only

Table 1414. Cluster Name

Name

Object ID

Description

Syntax

Access clusterName

1.3.6.1.4.1.674.10892.1.1800.10.1.8

Defines the name of the cluster.

DellString

Read-only

Cluster Group Variable Values

This section includes definitions for Server Administrator-specific variable values used in this section.

Table 1415. Cluster Type

Variable Name: DellClusterType

Data Type: Integer

Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown.

316 Server Administrator Group

Table 1415. Cluster Type (continued) highAvailabilityC luster(2)

The cluster type is a high-availability cluster.

Baseboard Management Controller Group

The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system. In addition to providing general information about the

BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC.

Baseboard Management Controller Group Tables

The objects in the BMC group define information about the BMC and the serial and LAN interfaces that can be used to access the BMC remotely to perform management activities. Objects for the serial interface define the serial connection mode, flow control type and bit rate. Objects for the LAN interface define the media access control (MAC) address, internet protocol (IP) address, subnet mask and default gateway.

The following MIB tables define the BMC group:

● Baseboard Management Controller Table

● Baseboard Management Controller Serial Interface Table

● Baseboard Management Controller LAN Interface Table

Baseboard Management Controller Table

Table 1416. BMC Table

Name

Object ID

Description

Syntax

Access bmcTable

1.3.6.1.4.1.674.10892.1.1900.10

Defines the Baseboard Management Controller Table.

SEQUENCE OF BmcTableEntry

Not accessible

Table 1417. BMC Table Entry

Name

Object ID

Description

Syntax

Access

Index bmcTableEntry

1.3.6.1.4.1.674.10892.1.1900.10.1

Defines the Baseboard Management Controller (BMC) Table Entry.

BmcTableEntry

Not accessible bmcChassisIndex

, bmcIndex

Table 1418. BMC Chassis Index

Name

Object ID bmcChassisIndex

1.3.6.1.4.1.674.10892.1.1900.10.1.1

Server Administrator Group 317

Table 1418. BMC Chassis Index (continued)

Description

Syntax

Access

Defines the index (one-based) of the associated chassis.

DellObjectRange

Read-only

Table 1419. BMC Index

Name

Object ID

Description

Syntax

Access bmcIndex

1.3.6.1.4.1.674.10892.1.1900.10.1.2

Defines the index (one-based) of the BMC.

DellObjectRange

Read-only

Table 1420. BMC State Capabilities

Name

Object ID

Description

Syntax

Access bmcStateCapabilities

1.3.6.1.4.1.674.10892.1.1900.10.1.3

Defines the state capabilities of the BMC.

DellStateCapabilities

Read-only

Table 1421. BMC State Settings

Name

Object ID

Description

Syntax

Access bmcStateSettings

1.3.6.1.4.1.674.10892.1.1900.10.1.4

Defines the state settings of the BMC.

DellStateSettings

Read-only

Table 1422. BMC Status

Name

Object ID

Description

Syntax

Access bmcStatus

1.3.6.1.4.1.674.10892.1.1900.10.1.5

Defines the status of the BMC.

DellStatus

Read-only

Table 1423. BMC Display Name

Name

Object ID

Description

Syntax

Access bmcDisplayName

1.3.6.1.4.1.674.10892.1.1900.10.1.6

Defines the display name of the BMC.

DellString

Read-only

Table 1424. BMC Description Name

Name

Object ID bmcDescriptionName

1.3.6.1.4.1.674.10892.1.1900.10.1.7

318 Server Administrator Group

Table 1424. BMC Description Name (continued)

Description

Syntax

Access

Defines the description of the BMC.

DisplayString

Read-only

Table 1425. BMC IPMI Version Name

Name

Object ID

Description

Syntax

Access bmcIPMIVersionName

1.3.6.1.4.1.674.10892.1.1900.10.1.8

Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports.

DellString

Read-only

Table 1426. BMC GUID

Name

Object ID

Description

Syntax

Access bmcGUID

1.3.6.1.4.1.674.10892.1.1900.10.1.9

Defines the Globally Unique ID (GUID) of the BMC.

Octet String

Read-only

Table 1427. BMC Type

Name

Object ID

Description

Syntax

Access bmcType

1.3.6.1.4.1.674.10892.1.1900.10.1.10

Defines the type of the BMC.

DellManagementControllerType

Read-only

Table 1428. BMC Module Name

Name

Object ID

Description

Syntax

Access bmcModuleName

1.3.6.1.4.1.674.10892.1.1900.10.1.11

Defines the module name for the BMC. The module name is present only on certain systems, such as modular systems.

DellString

Read-only

Table 1429. BMC IPv4 URL Name

Name

Object ID

Description

Syntax

Access bmcIPv4URLName

1.3.6.1.4.1.674.10892.1.1900.10.1.12

Defines the IPv4 URL for the BMC. The URL is not present on all systems.

DisplayString

Read-only

Table 1430. BMC IPv6 URL Name

Name bmcIPv6URLName

Server Administrator Group 319

Table 1430. BMC IPv6 URL Name (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1900.10.1.13

Defines the IPv6 URL for the BMC. The URL is not present on all systems.

DisplayString

Read-only

Table 1431. BMC Blade Form Factor

Name

Object ID

Description

Syntax

Access bmcBladeFormFactorName

1.3.6.1.4.1.674.10892.1.1900.10.1.14

Defines Blade Form Factor

DellBladeFormFactorType

Read-only

Baseboard Management Controller Serial Interface

Table 1432. BMC Serial Interface Table

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceTable

1.3.6.1.4.1.674.10892.1.1900.20

Defines the BMC Serial Interface Table.

SEQUENCE OF BmcSerialInterfaceTableEntry

Not accessible

Table 1433. BMC Serial Interface Table Entry

Name

Object ID

Description

Syntax

Access

Index bmcSerialInterfaceTableEntry

1.3.6.1.4.1.674.10892.1.1900.20.1

Defines the BMC Serial Interface Table Entry.

BmcSerialInterfaceTableEntry

Not accessible bmcSerialInterfaceChassisIndex

, bmcSerialInterfaceBMCIndex

, bmcSerialInterfaceIndex

Table 1434. BMC Serial Interface Chassis Index

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceChassisIndex

1.3.6.1.4.1.674.10892.1.1900.20.1.1

Defines the index (one-based) of the associated chassis.

DellObjectRange

Read-only

320 Server Administrator Group

Table 1435. BMC Serial Interface BMC Index

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceBMCIndex

1.3.6.1.4.1.674.10892.1.1900.20.1.2

Defines the index (one-based) of the associated BMC.

DellObjectRange

Read-only

Table 1436. BMC Serial Interface Index

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceIndex

1.3.6.1.4.1.674.10892.1.1900.20.1.3

Defines the index (one-based) of the BMC serial interface.

DellObjectRange

Read-only

Table 1437. BMC Serial Interface State Capabilities

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceStateCapabilities

1.3.6.1.4.1.674.10892.1.1900.20.1.4

Defines the state capabilities of the BMC serial interface.

DellStateCapabilities

Read-only

Table 1438. BMC Serial Interface State Settings

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceStateSettings

1.3.6.1.4.1.674.10892.1.1900.20.1.5

Defines the state settings of the BMC serial interface.

DellStateSettings

Read-only

Table 1439. BMC Serial Interface Status

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceStatus

1.3.6.1.4.1.674.10892.1.1900.20.1.6

Defines the status of the BMC serial interface.

DellStatus

Read-only

Table 1440. BMC Serial Interface Channel Number

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceChannelNumber

1.3.6.1.4.1.674.10892.1.1900.20.1.7

Defines the BMC channel number of the BMC serial interface.

DellUnsigned8BitRange

Read-only

Server Administrator Group 321

Table 1441. BMC Serial Interface Connection Mode Capabilities

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceConnectionModeCapabilities

1.3.6.1.4.1.674.10892.1.1900.20.1.8

Defines the connection mode capabilities of the BMC serial interface.

DellBMCSerialConnectionModeCapabilities

Read-only

Table 1442. BMC Serial Interface Connection Mode Settings

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceConnectionModeSettings

1.3.6.1.4.1.674.10892.1.1900.20.1.9

Defines the connection mode settings of the BMC serial interface.

DellBMCSerialConnectionModeSettings

Read-only

Table 1443. BMC Serial Interface Flow Control

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceFlowControl

1.3.6.1.4.1.674.10892.1.1900.20.1.10

Defines the flow control type of the BMC serial interface.

DellBMCSerialFlowControlType

Read-only

Table 1444. BMC Serial Interface Bit Rate

Name

Object ID

Description

Syntax

Access bmcSerialInterfaceBitRate

1.3.6.1.4.1.674.10892.1.1900.20.1.11

Defines the bit rate of the BMC serial interface.

DellBMCSerialBitRateType

Read-only

Baseboard Management Controller LAN Interface Table

Table 1445. BMC LAN Interface

Name

Object ID

Description

Syntax

Access bmcLANInterfaceTable

1.3.6.1.4.1.674.10892.1.1900.30

Defines the Baseboard Management Controller (BMC) LAN Interface Table.

SEQUENCE OF BmcLANInterfaceTableEntry

Not accessible

Table 1446. BMC LAN Interface Table Entry

Name

Object ID

Description

Syntax bmcLANInterfaceTableEntry

1.3.6.1.4.1.674.10892.1.1900.30.1

Defines the Baseboard Management Controller (BMC) LAN Interface Table Entry.

BmcLANInterfaceTableEntry

322 Server Administrator Group

Table 1446. BMC LAN Interface Table Entry (continued)

Access

Index

Not accessible bmcLANInterfaceChassisIndex

, bmcLANInterfaceBMCIndex

, bmcLANInterfaceIndex

Table 1447. BMC LAN Interface Chassis Index

Name

Object ID

Description

Syntax

Access bmcLANInterfaceChassisIndex

1.3.6.1.4.1.674.10892.1.1900.30.1.1

Defines the index (one-based) of the associated chassis.

DellObjectRange

Read-only

Table 1448. BMC LAN Interface BMC Index

Name

Object ID

Description

Syntax

Access bmcLANInterfaceBMCIndex

1.3.6.1.4.1.674.10892.1.1900.30.1.2

Defines the index (one-based) of the associated BMC.

DellObjectRange

Read-only

Table 1449. BMC LAN Interface Index

Name

Object ID

Description

Syntax

Access bmcLANInterfaceIndex

1.3.6.1.4.1.674.10892.1.1900.30.1.3

Defines the index (one-based) of the BMC LAN interface.

DellObjectRange

Read-only

Table 1450. BMC LAN Interface State Capabilities

Name

Object ID

Description

Syntax

Access bmcLANInterfaceStateCapabilities

1.3.6.1.4.1.674.10892.1.1900.30.1.4

Defines the state capabilities of the BMC LAN interface.

DellStateCapabilities

Read-only

Table 1451. BMC LAN Interface State Settings

Name

Object ID

Description bmcLANInterfaceStateSettings

1.3.6.1.4.1.674.10892.1.1900.30.1.5

Defines the state settings of the BMC LAN interface.

Server Administrator Group 323

Table 1451. BMC LAN Interface State Settings (continued)

Syntax

Access

DellStateSettings

Read-only

Table 1452. BMC LAN Interface Status

Name

Object ID

Description

Syntax

Access bmcLANInterfaceStatus

1.3.6.1.4.1.674.10892.1.1900.30.1.6

Defines the status of the BMC LAN interface.

DellStatus

Read-only

Table 1453. BMC LAN Interface Channel Number

Name

Object ID

Description

Syntax

Access bmcLANInterfaceChannelNumber

1.3.6.1.4.1.674.10892.1.1900.30.1.7

Defines the BMC channel number of the BMC LAN interface.

DellUnsigned8BitRange

Read-only

Table 1454. BMC LAN Interface IP Address Source

Name

Object ID

Description

Syntax

Access bmcLANInterfaceIPAddressSource

1.3.6.1.4.1.674.10892.1.1900.30.1.8

Defines the source type of the IP address of the BMC LAN interface.

DellBMCLANIPAddressSourceType

Read-only

Table 1455. BMC LAN Interface IP Address

Name

Object ID

Description

Syntax

Access bmcLANInterfaceIPAddress

1.3.6.1.4.1.674.10892.1.1900.30.1.9

Defines the IP address of the BMC LAN interface.

IpAddress

Read-only

Table 1456. BMC LAN Interface Subnet Mask Address

Name bmcLANInterfaceSubnetMaskAddress

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10892.1.1900.30.1.10

Defines the subnet mask of the BMC LAN interface.

IpAddress

Read-only

Table 1457. BMC LAN Interface Default Gateway Address

Name

Object ID

Description bmcLANInterfaceDefaultGatewayAddress

1.3.6.1.4.1.674.10892.1.1900.30.1.11

Defines the IP address of the default gateway for the BMC LAN interface.

324 Server Administrator Group

Table 1457. BMC LAN Interface Default Gateway Address (continued)

Syntax

Access

IpAddress

Read-only

Table 1458. BMC LAN Interface MAC Address

Name

Object ID

Description

Syntax

Access bmcLANInterfaceMACAddress

1.3.6.1.4.1.674.10892.1.1900.30.1.12

Defines the MAC address of the BMC LAN interface.

DellMACAddress

Read-only

Table 1459. BMC LAN Interface Alert Community Name

Name

Object ID

Description

Syntax

Access bmcLANInterfaceAlertCommunityName

1.3.6.1.4.1.674.10892.1.1900.30.1.13

Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface.

DisplayString (SIZE (0..32))

Read-only

Baseboard Management Controller Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 1460. Baseboard Management Controller

Variable Name: DellBMCSerialConnectionModeCapabilities

Data Type: Integer

These values are bit masks; therefore, combination values are possible.

Possible Data Values

-- none(0) modemBasic(1) modemPPP(2) modemTerminal(4) directBasic(8) directPPP(16) directTerminal(32)

Meaning of Data Value

No mode capabilities.

BMC serial interface supports Modem

Basic mode.

BMC serial interface supports Modem

Point to Point Protocol (PPP) mode.

BMC serial interface supports Modem

Terminal mode.

BMC serial interface supports Direct

Basic mode.

BMC serial interface supports Direct

PPP mode.

BMC serial interface supports Direct

Terminal mode.

Table 1461. BMC Serial Connection Mode Settings

Variable

Name: DellBMCSerialConnectionModeSettingsDellBMCSerialConnec tionModeCapabilities

Server Administrator Group 325

Table 1461. BMC Serial Connection Mode Settings (continued)

Data Type: Integer

These values are bit masks; therefore, combination values are possible.

Possible Data Values

-- none(0) modemBasic(1) modemPPP(2) modemTerminal(4) directBasic(8) directPPP(16) directTerminal(32)

Meaning of Data Value

No modes enabled.

Modem Basic mode is enabled.

Modem PPP mode is enabled.

Modem Terminal mode is enabled.

Direct Basic mode is enabled.

Direct PPP mode is enabled.

Direct Terminal mode is enabled.

Table 1462. BMC Serial Flow Control Type

Variable Name: DellBMCSerialFlowControlType

Data Type: Integer

Possible Data Values

-- none(0) rtscts(1) xonXoff(2)

Meaning of Data Value

No flow control used.

RTS/CTS (hardware) flow control used.

XON/XOFF flow control used.

Table 1463. BMC Serial Bit Rate Type

Variable Name: DellBMCSerialBitRateType

Data Type: Integer

Possible Data Values bps9600(6) bps19200(7) bps38400(8) bps57600(9) bps115200(10)

Meaning of Data Value

Bit rate is 9600 bps (bits per second)

Bit rate is 19200 bps

Bit rate is 38400 bps

Bit rate is 57600 bps

Bit rate is 115200 bps

Table 1464. BMC LAN IP Address Source Type

Variable Name: DellBMCLANIPAddressSourceType

Data Type: Integer

Possible Data Values

-- unspecified(0) static(1) dhcp(2) biosOrSystemSoftware(3) other(4)

Meaning of Data Value

Source is unspecified.

IP address is static.

Dynamic Host Configuration Protocol

(DHCP) used to obtain IP address.

BIOS or system software provided IP

Address.

Other protocol used to obtain IP address.

326 Server Administrator Group

Table 1465. BMC Management Controller Type

Variable Name: DellManagementControllerType

Data Type: Integer

Possible Data Values

-- legacyBMC(0) iDRAC(8) iDRAC6(10) iDRAC6Modular(11) iDRAC6BMC(13) iDRAC7(16) iDRAC7Modular(17) vrtxCMC(18) fx2CMC(19) iDRAC8(32) iDRAC8Modular(33)

Meaning of Data Value

Controller type is legacy Baseboard

Management Controller.

Controller type is iDRAC.

Controller type is Integrated Dell Remote

Access Controller 6.

Controller type is Integrated Dell Remote

Access Controller 6 (Modular).

Controller type is Integrated Dell Remote

Access Controller 6 (BMC mode).

Controller type is Integrated Dell Remote

Access Controller 7.

Controller type is Integrated Dell Remote

Access Controller 7 (Modular).

Controller type is VRTX Chassis

Management Controller (CMC).

Controller type is FX2 Chassis

Management Controller (CMC).

Controller type is Integrated Dell Remote

Access Controller 8.

Controller type is Integrated Dell Remote

Access Controller 8 (Modular).

Table 1466. Dell Blade Form Factor Type

Variable Name: DellBladeFormFactorType

Data Type: Integer

Possible Data Values formFactorTypeIsSingleWidthHa lfHeight(1) formFactorTypeIsDualWidthHalf

Height(2) formFactorTypeIsSingleWidthFu llHeight(3)

Meaning of Data Value

Form Factor Type is singleWidthHalfHeight.

Form Factor Type is

DualWidthHalfHeight.

Form Factor Type is

SingleWidthFullHeight.

formFactorTypeIsDualWidthFull

Height(4)

Form Factor Type is

DualWidthFullHeight.

formFactorTypeIsSingleWidthQu arterHeight(5) formFactorTypeIs1UHalfWidth(6

)

Form Factor Type is

SingleWidthQuarterHeight.

Form Factor Type is 1UHalfWidth.

formFactorTypeIs1UQuarterWidt h(7)

Form Factor Type is 1UQuarterWidth.

formFactorTypeIs1UFullWidth(8

)

Form Factor Type is 1UFullWidth.

Server Administrator Group 327

Table 1466. Dell Blade Form Factor Type (continued) notApplicable(256) Form Factor Type is Not Applicable for the system.

Field Replaceable Unit Group

A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility.

The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system.

Field Replaceable Unit Group Tables

The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units. The following MIB tables define the FRU group.

Table 1467. Field Replaceable Unit Table

Name

Object ID

Description

Syntax

Access fruTable

1.3.6.1.4.1.674.10892.1.2000.10

Defines the Field Replaceable Unit table.

SEQUENCE OF FruTableEntry

Not accessible

Table 1468. FRU Table Entry

Name

Object ID

Description

Syntax

Access

Index fruTableEntry

1.3.6.1.4.1.674.10892.1.2000.10.1

Defines the FRU Table Entry.

FruTableEntry

Not accessible fruChassisIndex

, fruIndex

Table 1469. FRU Chassis Index

Name

Object ID

Description

Syntax

Access fruChassisIndex

1.3.6.1.4.1.674.10892.1.2000.10.1.1

Defines the index (one-based) of the chassis containing the FRU.

DellObjectRange

Read-only

Table 1470. FRU Index

Name

Object ID

Description

Syntax fruIndex

1.3.6.1.4.1.674.10892.1.2000.10.1.2

Defines the index (one-based) of the FRU.

DellObjectRange

328 Server Administrator Group

Table 1470. FRU Index (continued)

Access Read-only

Table 1471. FRU Information Status

Name

Object ID

Description

Syntax

Access fruInformationStatus

1.3.6.1.4.1.674.10892.1.2000.10.1.3

Defines the status of the FRU table entry.

DellStatus

Read-only

Table 1472. FRU Information State

Name

Object ID

Description

Syntax

Access fruInformationState

1.3.6.1.4.1.674.10892.1.2000.10.1.4

Defines the state of the FRU information. Some information for the FRU may not be available if the state is other than ok(1).

DellFRUInformationState

Read-only

Table 1473. FRU Device Name

Name

Object ID

Description

Syntax

Access fruDeviceName

1.3.6.1.4.1.674.10892.1.2000.10.1.5

Defines the device name of the FRU.

DisplayString (SIZE (0..64))

Read-only

Table 1474. FRU Manufacturer Name

Name

Object ID

Description

Syntax

Access fruManufacturerName

1.3.6.1.4.1.674.10892.1.2000.10.1.6

Defines the manufacturer of the FRU.

DisplayString (SIZE (0..64))

Read-only

Table 1475. FRU Serial Number Name

Name

Object ID

Description

Syntax

Access fruSerialNumberName

1.3.6.1.4.1.674.10892.1.2000.10.1.7

Defines the serial number of the FRU.

DisplayString (SIZE (0..64))

Read-only

Table 1476. FRU Part Number Name

Name

Object ID

Description fruPartNumberName

1.3.6.1.4.1.674.10892.1.2000.10.1.8

Defines the part number of the FRU

Server Administrator Group 329

Table 1476. FRU Part Number Name (continued)

Syntax

Access

DisplayString (SIZE (0..64))

Read-only

Table 1477. FRU Revision Name

Name

Object ID

Description

Syntax

Access fruRevisionName

1.3.6.1.4.1.674.10892.1.2000.10.1.9

Defines the revision of the FRU.

DisplayString (SIZE (0..64))

Read-only

Table 1478. FRU Manufacturing Date Name

Name

Object ID

Description

Syntax

Access fruManufacturingDateName

1.3.6.1.4.1.674.10892.1.2000.10.1.10

Defines the manufacturing date of the FRU.

DellDateName

Read-only

Table 1479. FRU Asset Tag Name

Name

Object ID

Description

Syntax

Access fruAssetTagName

1.3.6.1.4.1.674.10892.1.2000.10.1.11

Defines the asset tag of the FRU.

DisplayString (SIZE (0..64))

Read-only

Field Replaceable Unit Group Variable Values

This section includes definitions for server administrator-specific variable values.

Table 1480. FRU Information State

Variable Name : DellFRUInformationState

Data Type : Integer

Possible Data Values ok(1) notSupported(2) notAvailable(3) checksumInvalid(4) corrupted(5)

Meaning of Data Value

FRU information is okay.

FRU information is not supported.

FRU information is not available.

FRU information checksum is invalid.

FRU information is corrupted.

330 Server Administrator Group

3

Storage Management Group

The Storage Management Group is composed of the following:

● Storage Management Group—information about the software product and system status.

● Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent.

● Global Data Group—system status.

● Physical Devices Group—physical devices managed by the software.

● Logical Devices Group—logical devices managed by the software.

● Storage Management Event Group—SNMP traps.

Topics:

Storage Management Group

Storage Management Information Group

Global Data Group

Physical Devices Group

Logical Devices Group

Storage Management Event Group

Storage Management Group

The Storage Management Information Base (MIB) Group defines the properties that identify information about the Storage

Management software product and the status of the system it manages.

NOTE: On Windows, the optional Storage Management component must first be installed to respond to SNMP queries in this group. On Linux several optional RPM packages for storage must be installed. See the Server Administrator Installation

Guide for more information.

Table 1481. Software Version

Name

Object ID

Description

Syntax

Access softwareVersion

1.3.6.1.4.1.674.10893.1.20.1

Identifies the version number of the storage management component of the systems management software.

DisplayString

Read-only

Table 1482. Global Status

Name

Object ID

Description globalStatus

1.3.6.1.4.1.674.10893.1.20.2

Identifies global health for the subsystem managed by the Storage Management software. This global status is customized for HP OpenView. Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group.

Possible values:

1: Critical

2: Warning

3: Normal

4: Unknown

Storage Management Group 331

Table 1482. Global Status (continued)

Syntax

Access

Integer

Read-only

Table 1483. Software Manufacturer

Name

Object ID

Description

Syntax

Access softwareManufacturer

1.3.6.1.4.1.674.10893.1.20.3

Identifies the manufacturer of the Storage Management software.

DisplayString

Read-only

Table 1484. Software Product

Name

Object ID

Description

Syntax

Access softwareProduct

1.3.6.1.4.1.674.10893.1.20.4

Identifies product information for the Storage Management software.

DisplayString

Read-only

Table 1485. Software Description

Name

Object ID

Description

Syntax

Access softwareDescription

1.3.6.1.4.1.674.10893.1.20.5

Identifies the product description for the Storage Management software.

DisplayString

Read-only

Storage Management Information Group

The Storage Management Information MIB Group defines the properties that identify the Storage Management software SNMP agent.

Table 1486. Display Name

Name

Object ID

Description

Syntax

Access displayName

1.3.6.1.4.1.674.10893.1.20.100.1

Identifies the name of this management software for display purposes.

DisplayString

Read-only

Table 1487. Description

Name

Object ID

Description

Syntax

Access description

1.3.6.1.4.1.674.10893.1.20.100.2

Provides a short description of this management software.

DisplayString

Read-only

332 Storage Management Group

Table 1488. Agent Vendor

Name

Object ID

Description

Syntax

Access

Table 1489. Agent Version

Name

Object ID

Description

Syntax

Access agentVendor

1.3.6.1.4.1.674.10893.1.20.100.3

Identifies the name of the management software manufacturer.

DisplayString

Read-only agentVersion

1.3.6.1.4.1.674.10893.1.20.100.4

This entry is obsolete. Refer to softwareVersion.

DisplayString

Read-only

Global Data Group

The Global Data Management Information Base (MIB) Group defines the properties that identify status information about the system that the Storage Management software is managing and about the Storage Management SNMP agent.

Table 1490. Agent System Global Status

Name

Object ID

Description

Syntax

Access agentSystemGlobalStatus

1.3.6.1.4.1.674.10893.1.20.110.1

This entry is obsolete. Use the value agentGlobalSystemStatus.

Integer

Read-only

Table 1491. Agent Last Global Status

Name

Object ID

Description

Syntax

Access agentLastGlobalStatus

1.3.6.1.4.1.674.10893.1.20.110.2

This entry is obsolete. Use the value agentLastGlobalSystemStatus.

Integer

Read-only

Table 1492. Agent Time Stamp

Name

Object ID

Description

Syntax

Access agentTimeStamp

1.3.6.1.4.1.674.10893.1.20.110.3

Identifies the last time that the agent values have been updated. Universal time in seconds since UTC 1/1/70.

Integer

Read-only

Table 1493. Agent Get Timeout

Name agentGetTimeout

Storage Management Group 333

Table 1493. Agent Get Timeout (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.110.4

Indicates the suggested timeout value in milliseconds for how long the SNMP getter should wait while attempting to poll the SNMP agent.

Integer

Read-only

Table 1494. Agent Modifiers

Name

Object ID

Description

Syntax

Access agentModifiers

1.3.6.1.4.1.674.10893.1.20.110.5

Identifies the agent functional modifiers. When set, the modifier is active. Bit definitions:

Bit 3: agent in debug mode. All other bits are product-specific.

Integer

Read-only

Table 1495. Agent Refresh Rate

Name

Object ID

Description

Syntax

Access agentRefreshRate

1.3.6.1.4.1.674.10893.1.20.110.6

Identifies the rate, given in seconds, at which the cached data for SNMP is refreshed.

The default value is 300 seconds, or 5 minutes.

Integer

Read-only

Table 1496. Agent Hostname

Name

Object ID

Description

Syntax

Access agentHostname

1.3.6.1.4.1.674.10893.1.20.110.7

This entry is obsolete for Storage Management.

DisplayString

Read-only

Table 1497. Agent IP Address

Name

Object ID

Description

Syntax

Access agentIPAddress

1.3.6.1.4.1.674.10893.1.20.110.8

This entry is obsolete for Storage Management.

DisplayString

Read-only

Table 1498. Agent Software Status

Name agentSoftwareStatus

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.110.9

This entry is obsolete for Storage Management.

DisplayString

Read-only

334 Storage Management Group

Table 1499. Agent SNMP Version

Name

Object ID

Description

Syntax

Access agentSnmpVersion

1.3.6.1.4.1.674.10893.1.20.110.10

This entry is obsolete. Refer to 0001 softwareVersion.

DisplayString

Read-only

Table 1500. Agent MIB Version

Name

Object ID

Description

Syntax

Access agentMibVersion

1.3.6.1.4.1.674.10893.1.20.110.11

Identifies the version of the Storage Management MIB.

DisplayString

Read-only

Table 1501. Agent Management Software URL Name

Name

Object ID

Description

Syntax

Access agentManagementSoftwareURLName

1.3.6.1.4.1.674.10893.1.20.110.12

Identifies the Universal Resource Locator (URL) of the systems management software.

DisplayString

Read-only

Table 1502. Agent Global System Status

Name

Object ID

Description agentGlobalSystemStatus

1.3.6.1.4.1.674.10893.1.20.110.13

Global health information for the subsystem managed by the Storage Management software. This global status should be used by applications other than HP OpenView.

HP OpenView should refer to the globalStatus in the root level object group. This is a rollup for the entire agent including any monitored devices. The status is intended to give initiative to an SNMP monitor to get further data when this status is abnormal.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

NOTE: This global status should be used by applications other than HP OpenView.

HP OpenView should refer to the globalStatus in the root level object group.

Syntax

Access

DellStatus

Read-only

Table 1503. Agent Last Global System Status

Name

Object ID agentLastGlobalSystemStatus

1.3.6.1.4.1.674.10893.1.20.110.14

Storage Management Group 335

Table 1503. Agent Last Global System Status (continued)

Description The previous global status of the system managed by the Storage Management software. Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1504. Agent Smart Thermal Shutdown

Name

Object ID

Description agentSmartThermalShutdown

1.3.6.1.4.1.674.10893.1.20.110.15

Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault

221S enclosures.

Possible values:

1: Enabled

2: Disabled

3: Not applicable

Syntax

Access

Integer

Read-only

Physical Devices Group

The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other. The following MIB tables define objects and relationships (connections) among the objects.

● Controller Table — describes available properties for each controller on the managed system.

● Channel Table — describes available properties for each channel on the managed system.

● Enclosure Table — describes available properties for each enclosure on the managed system.

● Array Disk Table — describes available properties for each physical array disk on the managed system.

● Array Disk Enclosure Connection Table — describes the connections between Fibre Channel array disks, their enclosure, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found.

● Array Disk Channel Connection Table — describes the connections between SCSI array disks, their channel, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate

MIB table for that object where all of the object properties can be found.

● Fan Table — describes available properties for each fan on the managed system.

● Fan Connection Table — describes the connection between each fan on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table.

● Power Supply Table — describes available properties for each power supply on the managed system.

● Power Supply Connection Table — describes the connection between each power supply on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table.

● Temperature Probe Table — describes available properties for each temperature probe on the managed system.

● Temperature Probe Connection Table — describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table.

● EMM Table — describes available properties for each Enclosure Management Module (EMM) on the managed system.

336 Storage Management Group

● EMM Connection Table — describes the connection between each EMM on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table.

● Battery Table — describes available properties for each controller battery on the managed system.

● Battery Connection Table — describes the connection between each battery on the managed system and its controller.

Each controller number in the table corresponds to that controller instance in the Controller Table.

Controller Table

This table describes available properties for each controller on the managed system.

The following object sets up the Controller Table.

Table 1505. Auto Configure Behavior

Name

Object ID

Description

Syntax

Access

Status controllerAutoconfigureBehavior

1.3.6.1.4.1.674.10893.1.20.130.1.1.75

Displays the current Auto Configure Behavior mode that is set on a controller.

DisplayString

Read-only

Mandatory

Table 1506. Controller Table

Name

Object ID

Description controllerTable

1.3.6.1.4.1.674.10893.1.20.130.1

Defines the controller table, which is a table of managed Redundant Array of

Independent disks (RAID) controllers. The number of entries is related to the number of

RAID controllers discovered in the system.

SEQUENCE OF ControllerEntry

Not accessible

Syntax

Access

Table 1507. Controller Entry

Name

Object ID

Description

Syntax

Access

Index controllerEntry

1.3.6.1.4.1.674.10893.1.20.130.1.1

Defines the controller table entry, which is an entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table.

ControllerEntry

Not accessible controllerNumber

Table 1508. Controller Number

Name

Object ID

Description

Syntax

Access controllerNumber

1.3.6.1.4.1.674.10893.1.20.130.1.1.1

Identifies the instance number of the controller entry.

Integer

Read-only

Storage Management Group 337

Table 1509. Controller Name

Name

Object ID

Description

Syntax

Access controllerName

1.3.6.1.4.1.674.10893.1.20.130.1.1.2

Identifies the name of the controller in this subsystem as represented in Storage

Management. Includes the controller type and instance. For example: PERC 3/QC 1.

DisplayString

Read-only

Table 1510. Controller Vendor

Name

Object ID

Description

Syntax

Access controllerVendor

1.3.6.1.4.1.674.10893.1.20.130.1.1.3

Identifies the controller's (re)seller's name.

DisplayString

Read-only

Table 1511. Controller Type

Name

Object ID

Description controllerType

1.3.6.1.4.1.674.10893.1.20.130.1.1.4

Identifies the type of this controller:

1: SCSI

2: PowerVault 660F

3: Power Vault 662F

4: Integrated/Intelligent Drive Electronics (IDE)

5: Serial Advanced Technology Architecture (SATA)

6: Serial Attached SCSI (SAS)

9: PCIe SSD

Integer

Read-only

Syntax

Access

Table 1512. Controller State

Name

Object ID

Description

Syntax

Access controllerState

1.3.6.1.4.1.674.10893.1.20.130.1.1.5

Identifies the status of the controller's subsystem (which includes any devices connected to it).

Possible states:

0: Unknown

1: Ready

2: Failed

3: Online

4: Offline

6: Degraded

Integer

Read-only

338 Storage Management Group

Table 1513. Controller Severity

Name

Object ID

Description

Syntax

Access controllerSeverity

1.3.6.1.4.1.674.10893.1.20.130.1.1.6

This entry is obsolete for Storage Management. It was replaced with RollUpStatus and

ComponentStatus for each device.

Integer

Read-only

Table 1514. Controller Rebuild Rate In Percent

Name

Object ID

Description

Syntax

Access controllerRebuildRateInPercent

1.3.6.1.4.1.674.10893.1.20.130.1.1.7

Identifies the percent of the compute cycles dedicated to rebuilding failed array disks.

Integer

Read-only

Table 1515. Controller Firmware Version

Name

Object ID

Description

Syntax

Access controllerFWVersion

1.3.6.1.4.1.674.10893.1.20.130.1.1.8

Identifies the controller's current firmware version.

DisplayString

Read-only

Table 1516. Controller Cache Size in Megabytes

Name controllerCacheSizeInMB

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.1.1.9

Identifies the controller's current amount of cache memory in megabytes. If this size is

0, it is less than a megabyte.

Integer

Read-only

Table 1517. Controller Cache Size in Bytes

Name

Object ID

Description

Syntax

Access controllerCacheSizeInBytes

1.3.6.1.4.1.674.10893.1.20.130.1.1.10

Identifies the controller's current amount of cache memory that is less than a megabyte.

This combined with the controllerCacheSizeInMB is the total amount of memory.

Integer

Read-only

Table 1518. Controller Physical Device Count

Name

Object ID

Description

Syntax controllerPhysicalDeviceCount

1.3.6.1.4.1.674.10893.1.20.130.1.1.11

Identifies the number of physical devices on the controller channel including both disks and the controller.

Integer

Storage Management Group 339

Table 1518. Controller Physical Device Count (continued)

Access Read-only

Table 1519. Controller Logical Device Count

Name

Object ID

Description

Syntax

Access controllerLogicalDeviceCount

1.3.6.1.4.1.674.10893.1.20.130.1.1.12

Identifies the number of virtual disks on the controller.

Integer

Read-only

Table 1520. Controller Partner Status

Name

Object ID

Description

Syntax

Access controllerPartnerStatus

1.3.6.1.4.1.674.10893.1.20.130.1.1.13

This entry is obsolete for Storage Management.

DisplayString

Read-only

Table 1521. Controller Host Port Count

Name controllerHostPortCount

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.1.1.14

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1522. Controller Memory Size in Megabytes

Name

Object ID

Description

Syntax

Access controllerMemorySizeInMB

1.3.6.1.4.1.674.10893.1.20.130.1.1.15

Identifies the size of memory in megabytes on the controller. If this size is 0, it is less than a megabyte. This attribute is only supported on Adaptec controllers.

Integer

Read-only

Table 1523. Controller Memory Size in Bytes

Name

Object ID

Description

Syntax

Access controllerMemorySizeInBytes

1.3.6.1.4.1.674.10893.1.20.130.1.1.16

Identifies the size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB is the total size of the memory. This attribute is only supported on Adaptec controllers.

Integer

Read-only

Table 1524. Controller Drive Channel Count

Name

Object ID controllerDriveChannelCount

1.3.6.1.4.1.674.10893.1.20.130.1.1.17

340 Storage Management Group

Table 1524. Controller Drive Channel Count (continued)

Description

Syntax

Access

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1525. Controller Fault Tolerant

Name

Object ID

Description

Syntax

Access controllerFaultTolerant

1.3.6.1.4.1.674.10893.1.20.130.1.1.18

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1526. Controller C0 Port 0 World Wide Name

Name

Object ID

Description

Syntax

Access controllerC0Port0WorldWideName

1.3.6.1.4.1.674.10893.1.20.130.1.1.19

This entry is obsolete. Fibre channel is not supported in Storage Management.

DisplayString

Read-only

Table 1527. Controller C0 Port 0 Name

Name

Object ID

Description

Syntax

Access controllerC0Port0Name

1.3.6.1.4.1.674.10893.1.20.130.1.1.20

This entry is obsolete. Fibre channel is not supported in Storage Management.

DisplayString

Read-only

Table 1528. Controller C0 Port 0 ID

Name

Object ID

Description

Syntax

Access controllerC0Port0ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.21

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1529. Controller C0 Target

Name

Object ID

Description

Syntax

Access controllerC0Target

1.3.6.1.4.1.674.10893.1.20.130.1.1.22

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1530. Controller C0 Channel

Name

Object ID controllerC0Channel

1.3.6.1.4.1.674.10893.1.20.130.1.1.23

Storage Management Group 341

Table 1530. Controller C0 Channel (continued)

Description

Syntax

Access

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1531. Controller C0 Operating System Controller

Name

Object ID

Description

Syntax

Access controllerC0OSController

1.3.6.1.4.1.674.10893.1.20.130.1.1.24

This entry is obsolete. Fibre channel is not supported in Storage Management.

DisplayString

Read-only

Table 1532. Controller C0 Battery State

Name

Object ID

Description

Syntax

Access controllerC0BatteryState

1.3.6.1.4.1.674.10893.1.20.130.1.1.25

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1533. Controller C1 Port 0 World Wide Name

Name

Object ID

Description

Syntax

Access controllerC1Port0WWN

1.3.6.1.4.1.674.10893.1.20.130.1.1.26

This entry is obsolete. Fibre channel is not supported in Storage Management.

DisplayString

Read-only

Table 1534. Controller C1 Port 0 Name

Name

Object ID

Description

Syntax

Access controllerC1Port0Name

1.3.6.1.4.1.674.10893.1.20.130.1.1.27

This entry is obsolete. Fibre channel is not supported in Storage Management.

DisplayString

Read-only

Table 1535. Controller C1 Port 0 ID

Name

Object ID

Description

Syntax

Access controllerC1Port0ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.28

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1536. Controller C1 Target

Name

Object ID controllerC1Target

1.3.6.1.4.1.674.10893.1.20.130.1.1.29

342 Storage Management Group

Table 1536. Controller C1 Target (continued)

Description

Syntax

Access

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1537. Controller C1 Channel

Name

Object ID

Description

Syntax

Access controllerC1Channel

1.3.6.1.4.1.674.10893.1.20.130.1.1.30

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1538. Controller C1 Operating System Controller

Name

Object ID

Description

Syntax

Access controllerC1OSController

1.3.6.1.4.1.674.10893.1.20.130.1.1.31

This entry is obsolete. Fibre channel is not supported in Storage Management.

DisplayString

Read-only

Table 1539. Controller Battery State C1

Name

Object ID

Description

Syntax

Access controllerC1BatteryState

1.3.6.1.4.1.674.10893.1.20.130.1.1.32

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1540. Controller Node World Wide Name

Name

Object ID

Description

Syntax

Access controllerNodeWWN

1.3.6.1.4.1.674.10893.1.20.130.1.1.33

This entry is obsolete. Fibre channel is not supported in Storage Management.

DisplayString

Read-only

Table 1541. Controller C0 Port 1 World Wide Name

Name

Object ID

Description

Syntax

Access controllerC0Port1WWN

1.3.6.1.4.1.674.10893.1.20.130.1.1.34

This entry is obsolete. Fibre channel is not supported in Storage Management.

DisplayString

Read-only

Table 1542. Controller C1 Port 1 World Wide Name

Name

Object ID controllerC1Port1WWN

1.3.6.1.4.1.674.10893.1.20.130.1.1.35

Storage Management Group 343

Table 1542. Controller C1 Port 1 World Wide Name (continued)

Description

Syntax

Access

This entry is obsolete. Fibre channel is not supported in Storage Management.

DisplayString

Read-only

Table 1543. Controller Battery Charge Count

Name

Object ID

Description

Syntax

Access controllerBatteryChargeCount

1.3.6.1.4.1.674.10893.1.20.130.1.1.36

This entry is obsolete. Fibre channel is not supported in Storage Management.

Integer

Read-only

Table 1544. Controller Roll-Up Status

Name

Object ID

Description controllerRollUpStatus

1.3.6.1.4.1.674.10893.1.20.130.1.1.37

Indicates severity of the controller state. This is the combined status of the controller and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1545. Controller Component Status

Name

Object ID

Description controllerComponentStatus

1.3.6.1.4.1.674.10893.1.20.130.1.1.38

Indicates the status of the controller itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

344 Storage Management Group

Table 1546. Controller Nexus ID

Name

Object ID

Description

Syntax

Access controllerNexusID

1.3.6.1.4.1.674.10893.1.20.130.1.1.39

Durable unique ID for this controller.

DisplayString

Read-only

Table 1547. Controller Alarm State

Name

Object ID

Description controllerAlarmState

1.3.6.1.4.1.674.10893.1.20.130.1.1.40

Indicates state, or setting for the controller's alarm.

Possible values:

1: Enabled

2: Disabled

3: Not Applicable

Syntax

Access

Integer

Read-only

Table 1548. Controller Driver Version

Name controllerDriverVersion

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.1.1.41

Indicates currently installed driver version of the controller

DisplayString

Read-only

Table 1549. Controller PCI Slot

Name

Object ID

Description

Syntax

Access controllerPCISlot

1.3.6.1.4.1.674.10893.1.20.130.1.1.42

Indicates the PCI slot number or embedded number for controllers on the motherboard

DisplayString

Read-only

Table 1550. Controller Cluster Mode

Name

Object ID

Description controllerClusterMode

1.3.6.1.4.1.674.10893.1.20.130.1.1.43

Identifies if the controller is in cluster mode.

Possible values:

1: Enabled

2: Disabled

3: Active (enabled and active)

99: Not Applicable

Syntax Integer

Storage Management Group 345

Table 1550. Controller Cluster Mode (continued)

Access Read-only

Table 1551. Controller Minimum Firmware Version

Name

Object ID

Description

Syntax

Access controllerMinFWVersion

1.3.6.1.4.1.674.10893.1.20.130.1.1.44

The minimum firmware version for Storage Management to support the controller.

DisplayString

Read-only

Table 1552. Controller Minimum Driver Version

Name

Object ID

Description

Syntax

Access controllerMinDriverVersion

1.3.6.1.4.1.674.10893.1.20.130.1.1.45

The minimum driver version for Storage Management to support the controller.

DisplayString

Read-only

Table 1553. Controller SCSI Initiator ID

Name controllerSCSIInitiatorID

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.1.1.46

The SCSI ID of the initiator.

Integer

Read-only

Table 1554. Controller Channel Count

Name

Object ID

Description

Syntax

Access controllerChannelCount

1.3.6.1.4.1.674.10893.1.20.130.1.1.47

The number of channels on the controller.

Integer

Read-only

Table 1555. Controller Reconstruct Rate

Name

Object ID

Description

Syntax

Access controllerReconstructRate

1.3.6.1.4.1.674.10893.1.20.130.1.1.48

The rate for reconstruct on the controller.

Integer

Read-only

Table 1556. Controller Patrol Read Rate

Name

Object ID

Description

Syntax controllerPatrolReadRate

1.3.6.1.4.1.674.10893.1.20.130.1.1.49

The rate for patrol read on the controller.

Integer

346 Storage Management Group

Table 1556. Controller Patrol Read Rate (continued)

Access Read-only

Table 1557. Controller BGI Rate

Name

Object ID

Description

Syntax

Access controllerBGIRate

1.3.6.1.4.1.674.10893.1.20.130.1.1.50

The rate for background initialization on the controller.

Integer

Read-only

Table 1558. Controller Check Consistency Rate

Name

Object ID

Description

Syntax

Access controllerCheckConsistencyRate

1.3.6.1.4.1.674.10893.1.20.130.1.1.51

The rate for check consistency on the controller.

Integer

Read-only

Table 1559. Controller Patrol Read Mode

Name controllerPatrolReadMode

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.1.1.52

Identifies the patrol read mode. Possible values: 1: Automatic (enabled) 2: Manual

(enabled) 3: Disabled

Integer

Read-only

Table 1560. Controller Patrol Read State

Name

Object ID

Description controllerPatrolReadState

1.3.6.1.4.1.674.10893.1.20.130.1.1.53

The state of the patrol read.

Possible values:

1: Stopped - not running

2: Ready - ready to start

4: Active - is running

8: Aborted - has aborted

Syntax

Access

Integer

Read-only

Table 1561. Controller Patrol Read Iterations

Name

Object ID

Description

Syntax

Access controllerPatrolReadIterations

1.3.6.1.4.1.674.10893.1.20.130.1.1.54

The number of times Patrol Read has been run on this controller.

Integer

Read-only

Storage Management Group 347

Table 1562. Controller Storport Driver Version

Name

Object ID

Description

Syntax

Access controllerStorportDriverVersion

1.3.6.1.4.1.674.10893.1.20.130.1.1.55

Provides current Windows OS storport driver version. Not applicable for Linux.

Octet String

Read-only

Table 1563. Controller Minimum Required Storport Version

Name

Object ID

Description

Syntax

Access controllerMinimumRequiredStorportVersion

1.3.6.1.4.1.674.10893.1.20.130.1.1.56

Provides minimum required storport driver version for Windows OS only.

Octet String

Read-only

Table 1564. Controller Encryption Capable

Name

Object ID

Description

Syntax

Access controllerEncryptionCapable

1.3.6.1.4.1.674.10893.1.20.130.1.1.57

Indicates encryption capability of the controller. Value: 1 - Capable, 99 - Not Applicable

Integer

Read-only

Table 1565. Controller Encryption Key Persent

Name

Object ID

Description controllerEncryptionKeyPresent

1.3.6.1.4.1.674.10893.1.20.130.1.1.58

Indicates presence of encryption key for the controller.

Value: 1 - Yes, 0 - No, 99 - Not Applicable

Syntax

Access

Integer

Read-only

Table 1566. Controller Persistent Hot Spare

Name

Object ID

Description controllerPersistentHotSpare

1.3.6.1.4.1.674.10893.1.20.130.1.1.59

Indicates Persistent Hot Spare capability of the controller.

Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined /Not applicable

Syntax

Access

Integer

Read-only

Table 1567. Controller Spin Down Unconfigured Drives

Name

Object ID

Description controllerSpinDownUnconfiguredDrives

1.3.6.1.4.1.674.10893.1.20.130.1.1.60

Indicates controller capability to put unconfigured drives in power save mode. Value: 1 -

Enabled, 0 - Disabled, 99 - Undetermined /Not applicable

348 Storage Management Group

Table 1567. Controller Spin Down Unconfigured Drives (continued)

Syntax

Access

Integer

Read-only

Table 1568. Controller Spin Down Hot Spare Drives

Name

Object ID

Description

Syntax

Access controllerSpinDownHotSpareDrives

1.3.6.1.4.1.674.10893.1.20.130.1.1.61

Indicates controller capability to put hot spare drives in power save mode. Value: 1 -

Enabled, 0 - Disabled, 99 - Undetermined /Not applicable

Integer

Read-only

Table 1569. Controller Spin Down Time Interval

Name

Object ID

Description controllerSpinDownTimeInterval

1.3.6.1.4.1.674.10893.1.20.130.1.1.62

Shows the duration in minutes after which, the unconfigured or hot spare drives is spun down to power save mode. Value: 30 to 1440

NOTE: A value of 9999 indicates that the feature is not available.

Syntax

Access

Integer

Read-only

Table 1570. Controller Encryption Mode

Name

Object ID

Description

Syntax

Access controllerEncryptionMode

1.3.6.1.4.1.674.10893.1.20.130.1.1.63

Indicates the current encryption mode of the controller. Value: 0 - No Encryption, 1 -

Local Key Management (LKM), 2 - Dell Key Management (DKM), 99 - Not Applicable

Integer

Read-only

Table 1571. Controller CacheCade

Name

Object ID

Description

Syntax

Access controllerCacheCade

1.3.6.1.4.1.674.10893.1.20.130.1.1.64

Indicates if the controller is CacheCade capable or not. Value: 1 - Capable, 0 - Not

Capable, 99 - Undetermined

Integer

Read-only

Table 1572. Controller Spin Down Configured Drives

Name

Object ID

Description

Syntax

Access controllerSpinDownConfiguredDrives

1.3.6.1.4.1.674.10893.1.20.130.1.1.65

Indicates controller capability to spin down configured physical disks. Value: 0 -

Disabled, 1 - Enabled, 99 - Undetermined

Integer

Read-only

Storage Management Group 349

Table 1573. Controller Automatic Power Saving

Name

Object ID

Description

Syntax

Access controllerAutomaticPowerSaving

1.3.6.1.4.1.674.10893.1.20.130.1.1.66

Indicates controller capability for automatic power saving. Value: 0 - Disabled, 1 -

Enabled, 99 - Undetermined

Integer

Read-only

Table 1574. Controller Configured Drives SpinUp Time

Name

Object ID

Description

Syntax

Access controllerConfiguredDrivesSpinUpTime

1.3.6.1.4.1.674.10893.1.20.130.1.1.67

Indicates configured drives spin up start time. Value: 1:00 AM to 12:59 PM, 9999 -

Undetermined

DisplayString

Read-only

Table 1575. Controller Configured Drives SpinUp TimeInterval

Name

Object ID

Description controllerConfiguredDrivesSpinUpTimeInterval

1.3.6.1.4.1.674.10893.1.20.130.1.1.68

Indicates configured drives spin up time interval in hours. This value is added with configured drives start time to arrive at time window in which configured drives are always spin up.

Value: 1 .. 24, 9999 - Undetermined

Syntax

Access

Integer

Read-only

Table 1576. Controller Preserved Cache

Name

Object ID

Description controllerPreservedCache

1.3.6.1.4.1.674.10893.1.20.130.1.1.69

Indicates if preserved cache is present on the controller. Values:

1- Yes

0 - No

99 - Not available / Not applicable

Syntax

Access

Integer

Read-only

Table 1577. Controller PI Enable

Name

Object ID

Description controllerPIEnable

1.3.6.1.4.1.674.10893.1.20.130.1.1.70

Indicates if T10 PI is enabled on a controller.

Values are:

0 : T10 PI disabled

1 : T10 PI enabled

350 Storage Management Group

Table 1577. Controller PI Enable (continued)

Syntax

Access

Integer

Read-only

Table 1578. Controller Current Mode

Name

Object ID

Description

Syntax

Access controllerCurrentMode

1.3.6.1.4.1.674.10893.1.20.130.1.1.71

Indicates the current controller mode.

DisplayString

Read-only

Table 1579. Front Chassis Slot

Name

Object ID

Description

Syntax

Access frontChassisSlot

1.3.6.1.4.1.674.10893.1.20.130.1.1.72

Shows the physical slot on the chassis for stash.

Integer

Read-only

Table 1580. Controller Instance

Name

Object ID

Description

Syntax

Access controllerInstance

1.3.6.1.4.1.674.10893.1.20.130.1.1.73

Shows the current instance of the controller for stash.

Integer

Read-only

Table 1581. Controller Non-RAID Disk Cache Policy

Name

Object ID

Description

Syntax

Access controllerNonRAIDdiskCachePolicy

1.3.6.1.4.1.674.10893.1.20.130.1.1.74

Displays the current disk write cache policy for Non-RAID disks.

DisplayString

Read-only

Channel Table

This table describes available properties for each channel on the managed system.

The following object sets up the Channel Table.

Table 1582. Channel Table

Name

Object ID

Description

Syntax

Access channelTable

1.3.6.1.4.1.674.10893.1.20.130.2

Defines the channel table.

SEQUENCE OF ChannelEntry

Not accessible

Storage Management Group 351

Table 1583. Channel Entry

Name

Object ID

Description

Syntax

Access

Index

Table 1584. Channel Number

Name

Object ID

Description

Syntax

Access

Table 1585. Channel Name

Name

Object ID

Description channelEntry

1.3.6.1.4.1.674.10893.1.20.130.2.1

Defines the channel table entry.

ChannelEntry

Not accessible channelNumber channelNumber

1.3.6.1.4.1.674.10893.1.20.130.2.1.1

Identifies the instance number of the channel entry.

Integer

Read-only channelName

1.3.6.1.4.1.674.10893.1.20.130.2.1.2

Identifies the name of the channel as represented in Storage Management. The name includes the word channel and the instance. For example: Channel 1.

DisplayString

Read-only

Syntax

Access

Table 1586. Channel State

Name

Object ID

Description

Syntax

Access

Table 1587. Channel Severity

Name

Object ID

Description

Syntax channelState

1.3.6.1.4.1.674.10893.1.20.130.2.1.3

Identifies the current state of this channel.

Possible states:

0: Unknown

1: Ready - The I/O has resumed.

2: Failed

3: Online

4: Offline - The I/O has paused.

6: Degraded

Integer

Read-only channelSeverity

1.3.6.1.4.1.674.10893.1.20.130.2.1.4

This entry is obsolete for Storage Management. It was replaced with RollUpStatus and

ComponentStatus for each device.

Integer

352 Storage Management Group

Table 1587. Channel Severity (continued)

Access Read-only

Table 1588. Channel Termination

Name

Object ID

Description channelTermination

1.3.6.1.4.1.674.10893.1.20.130.2.1.5

Identifies the type of SCSI termination on this channel. Termination is required for proper operation of this channel.

Possible values:

1: Wide Termination (16 bit)

2: Narrow Termination (8 bit)

3: Not Terminated

Syntax

Access

Integer

Read-only

Table 1589. Channel SCSI ID

Name

Object ID

Description

Syntax

Access channelSCSIID

1.3.6.1.4.1.674.10893.1.20.130.2.1.6

Identifies the SCSI ID of the controller to which the channel belongs.

Integer

Read-only

Table 1590. Channel Roll-Up Status

Name channelRollUpStatus

Object ID

Description

1.3.6.1.4.1.674.10893.1.20.130.2.1.7

Identifies the severity of the channel state. This is the combined status of the channel and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1591. Channel Component Status

Name

Object ID

Description channelComponentStatus

1.3.6.1.4.1.674.10893.1.20.130.2.1.8

The status of the channel itself without the propagation of any contained component status.

Possible values:

1: Other

Storage Management Group 353

Table 1591. Channel Component Status (continued)

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1592. Channel Nexus ID

Name

Object ID

Description

Syntax

Access channelNexusID

1.3.6.1.4.1.674.10893.1.20.130.2.1.9

Durable unique ID for this channel.

DisplayString

Read-only

Table 1593. Channel Data Rate

Name

Object ID

Description

Syntax

Access channelDataRate

1.3.6.1.4.1.674.10893.1.20.130.2.1.10

Identifies the data rate of this channel.

DisplayString

Read-only

Table 1594. Channel Bus Type

Name

Object ID

Description

Syntax

Access channelBusType

1.3.6.1.4.1.674.10893.1.20.130.2.1.11

The bus type of the channel.

Possible values:

1: SCSI

2: IDE

3: Fibre Channel

4: Serial Storage Architecture (SSA)

6: Universal Serial Bus (USB)

7: SATA

8: SAS

9: PCIe

Integer

Read-only

Enclosure Table

The following tables describe theavailable properties for each enclosure on the managed system.

The following object sets up the Enclosure Table.

354 Storage Management Group

Table 1595. Enclosure Table

Name

Object ID

Description

Syntax

Access enclosureTable

1.3.6.1.4.1.674.10893.1.20.130.3

Defines the enclosure table.

SEQUENCE OF EnclosureEntry

Not accessible

Table 1596. Enclosure Entry

Name

Object ID

Description

Syntax

Access

Index enclosureEntry

1.3.6.1.4.1.674.10893.1.20.130.3.1

Defines the enclosure table entry.

EnclosureEntry

Not accessible enclosureNumber

Table 1597. Enclosure Number

Name

Object ID

Description

Syntax

Access enclosureNumber

1.3.6.1.4.1.674.10893.1.20.130.3.1.1

Identifies the instance number of the enclosure entry.

Integer

Read-only

Table 1598. Enclosure Name

Name

Object ID

Description

Syntax

Access

Table 1600. Enclosure State

Name

Object ID

Description enclosureName

1.3.6.1.4.1.674.10893.1.20.130.3.1.2

Identifies the enclosure's name as represented in Storage Management.

DisplayString

Read-only

Table 1599. Enclosure Vendor

Name

Object ID

Description

Syntax

Access enclosureVendor

1.3.6.1.4.1.674.10893.1.20.130.3.1.3

Identifies the enclosure's (re)seller's name.

DisplayString

Read-only enclosureState

1.3.6.1.4.1.674.10893.1.20.130.3.1.4

The current condition of the enclosure (which includes any devices connected to it.)

Possible values:

0: Unknown

Storage Management Group 355

Table 1600. Enclosure State (continued)

1: Ready

2: Failed

3: Online

4: Offline

6: Degraded

Syntax

Access

Integer

Read-only

Table 1601. Enclosure Severity

Name

Object ID

Description

Syntax

Access enclosureSeverity

1.3.6.1.4.1.674.10893.1.20.130.3.1.5

This entry is obsolete for Storage Management. It was replaced with RollUpStatus and

ComponentStatus for each device.

Integer

Read-only

Table 1602. Enclosure ID

Name

Object ID

Description

Syntax

Access enclosureID

1.3.6.1.4.1.674.10893.1.20.130.3.1.6

Represents unique id for an enclosure.

DisplayString

Read-only

Table 1603. Enclosure Processor Version

Name

Object ID

Description

Syntax

Access enclosureProcessorVersion

1.3.6.1.4.1.674.10893.1.20.130.3.1.7

This entry is obsolete for Storage Management.

DisplayString

Read-only

Table 1604. Enclosure Service Tag

Name

Object ID

Description

Syntax

Access enclosureServiceTag

1.3.6.1.4.1.674.10893.1.20.130.3.1.8

The enclosure identification used when consulting customer support.

DisplayString

Read-only

Table 1605. Enclosure Asset Tag

Name

Object ID

Description

Syntax enclosureAssetTag

1.3.6.1.4.1.674.10893.1.20.130.3.1.9

Customer definable asset tag for the enclosure.

DisplayString

356 Storage Management Group

Table 1605. Enclosure Asset Tag (continued)

Access Read-only

Table 1606. Enclosure Asset Name

Name

Object ID

Description

Syntax

Access enclosureAssetName

1.3.6.1.4.1.674.10893.1.20.130.3.1.10

Customer definable asset name of the enclosure.

DisplayString

Read-only

Table 1607. Enclosure Split Bus Part Number

Name

Object ID

Description

Syntax

Access enclosureSplitBusPartNumber

1.3.6.1.4.1.674.10893.1.20.130.3.1.11

Identifies the enclosure's split bus part number.

DisplayString

Read-only

Table 1608. Enclosure Product ID

Name enclosureProductID

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.3.1.12

Identifies the enclosure's product identification. This also corresponds to the enclosure type.

DisplayString

Read-only

Table 1609. Enclosure Kernel Version

Name

Object ID

Description

Syntax

Access enclosureKernelVersion

1.3.6.1.4.1.674.10893.1.20.130.3.1.13

This entry is obsolete for Storage Management.

DisplayString

Read-only

Table 1610. Enclosure ESM1 Part Number

Name

Object ID

Description

Syntax

Access enclosureESM1PartNumber

1.3.6.1.4.1.674.10893.1.20.130.3.1.14

This entry is obsolete for Storage Management.

DisplayString

Read-only

Table 1611. Enclosure ESM2 Part Number

Name

Object ID

Description enclosureESM2PartNumber

1.3.6.1.4.1.674.10893.1.20.130.3.1.15

This entry is obsolete for Storage Management.

Storage Management Group 357

Table 1611. Enclosure ESM2 Part Number (continued)

Syntax

Access

DisplayString

Read-only

Table 1612. Enclosure Type

Name

Object ID

Description

Syntax

Access enclosureType

1.3.6.1.4.1.674.10893.1.20.130.3.1.16

Indicates the type of the enclosure.

Possible values:

1: Internal

2: Dell PowerVault 200S (PowerVault 201S)

3: Dell PowerVault 210S (PowerVault 211S)

4: Dell PowerVault 220S (PowerVault 221S)

5: Dell PowerVault 660F

6: Dell PowerVault 224F

7: Dell PowerVault 660F/PowerVault 224F

8: Dell MD1000 9: Dell MD1120

DisplayString

Read-only

Table 1613. Enclosure Processor2 Version

Name

Object ID

Description

Syntax

Access enclosureProcessor2Version

1.3.6.1.4.1.674.10893.1.20.130.3.1.17

This entry is obsolete for Storage Management.

DisplayString

Read-only

Table 1614. Enclosure Configuration

Name enclosureConfig

Object ID

Description

1.3.6.1.4.1.674.10893.1.20.130.3.1.18

Identifies the current configuration of the enclosure's backplane.

Possible values:

1: Joined

2: Split Bus

3: Clustered

4: Unified

Syntax

Access

Integer

Read-only

Table 1615. Enclosure Channel Number

Name

Object ID

Description enclosureChannelNumber

1.3.6.1.4.1.674.10893.1.20.130.3.1.19

Identifies the channel number, or bus, to which the enclosure is connected.

358 Storage Management Group

Table 1615. Enclosure Channel Number (continued)

Syntax

Access

Integer

Read-only

Table 1616. Enclosure Alarm

Name

Object ID

Description

Syntax

Access enclosureAlarm

1.3.6.1.4.1.674.10893.1.20.130.3.1.20

Identifies the current status of the enclosure's alarm (PowerVault 220S and PowerVault

221S only.)

Possible values:

1: Disabled

2: Enabled

Integer

Read-only

Table 1617. Enclosure Backplane Part Number

Name

Object ID

Description

Syntax

Access enclosureBackplanePartNumber

1.3.6.1.4.1.674.10893.1.20.130.3.1.21

Identifies the part number of the enclosure's backplane.

Integer

Read-only

Table 1618. Enclosure SCSI ID

Name

Object ID

Description

Syntax

Access enclosureSCSIID

1.3.6.1.4.1.674.10893.1.20.130.3.1.22

Identifies the SCSI ID of the controller to which this enclosure is attached.

Integer

Read-only

Table 1619. Enclosure Roll-Up Status

Name

Object ID

Description enclosureRollUpStatus

1.3.6.1.4.1.674.10893.1.20.130.3.1.23

Identifies the severity of the enclosure state. This is the combined status of the enclosure and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Storage Management Group 359

Table 1620. Enclosure Component Status

Name

Object ID

Description enclosureComponentStatus

1.3.6.1.4.1.674.10893.1.20.130.3.1.24

The status of the enclosure itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1621. Enclosure Nexus ID

Name

Object ID

Description

Syntax

Access enclosureNexusID

1.3.6.1.4.1.674.10893.1.20.130.3.1.25

Durable unique ID for this enclosure.

Integer

Read-only

Table 1622. Enclosure FirmWare Version

Name

Object ID

Description

Syntax

Access enclosureFirmwareVersion

1.3.6.1.4.1.674.10893.1.20.130.3.1.26

The firmware version of the enclosure.

DisplayString

Read-only

Table 1623. Enclosure SCSI Rate

Name

Object ID

Description

Syntax

Access enclosureSCSIRate

1.3.6.1.4.1.674.10893.1.20.130.3.1.27

Actual SCSI rate in the enclosure.

DisplayString

Read-only

Table 1624. Enclosure Part Number

Name

Object ID

Description

Syntax

Access enclosurePartNumber

1.3.6.1.4.1.674.10893.1.20.130.3.1.28

The part number of the enclosure.

DisplayString

Read-only

360 Storage Management Group

Table 1625. Enclosure Serial Number

Name

Object ID

Description

Syntax

Access enclosureSerialNumber

1.3.6.1.4.1.674.10893.1.20.130.3.1.29

Serial number of the enclosure.

DisplayString

Read-only

Table 1626. Enclosure SAS Address

Name

Object ID

Description

Syntax

Access enclosureSASAddress

1.3.6.1.4.1.674.10893.1.20.130.3.1.30

The specified SAS address if this is a SAS enclosure.

DisplayString

Read-only

Table 1627. Enclosure Occupied Slot Count

Name

Object ID

Description enclosureOccupiedSlotCount

1.3.6.1.4.1.674.10893.1.20.130.3.1.31

Shows the number of physical disk slots occupied in a storage enclosure.

NOTE: A value of 9999 indicates that the feature is not available.

Syntax

Access

Integer

Read-only

Table 1628. Enclosure Total Slots

Name

Object ID

Description enclosureTotalSlots

1.3.6.1.4.1.674.10893.1.20.130.3.1.32

Shows the total number of physical slots in a storage enclosure; it includes total count of occupied and empty slots.

NOTE: A value of 9999 indicates that the feature is not available.

Syntax

Access

Integer

Read-only

Table 1629. Enclosure Empty Slot Count

Name

Object ID

Description enclosureEmptySlotCount

1.3.6.1.4.1.674.10893.1.20.130.3.1.33

Shows the number of empty physical disk slots in a storage enclosure.

NOTE: A value of 9999 indicates that the feature is not available

Syntax

Access

Integer

Read-only

Table 1630. Enclosure Express Service Code

Name

Object ID enclosureExpressServiceCode

1.3.6.1.4.1.674.10893.1.20.130.3.1.34

Storage Management Group 361

Table 1630. Enclosure Express Service Code (continued)

Description

Syntax

Access

Express Service Code (ESC) is base 10 converted numerical value of service tag.

DisplayString

Read-only

Array Disk Table

This table describes available properties for each physical array disk on the managed system.

The following object sets up the Array Disk Table.

Table 1631. Array Disk Table

Name

Object ID

Description

Syntax

Access arrayDiskTable

1.3.6.1.4.1.674.10893.1.20.130.4

Defines the array disk table.

SEQUENCE OF ArrayDiskEntry

Not accessible

Table 1632. Array Disk Entry

Name

Object ID

Description

Syntax

Access

Index arrayDiskEntry

1.3.6.1.4.1.674.10893.1.20.130.4.1

Defines the array disk table entry.

ArrayDiskEntry

Not accessible arrayDiskNumber

Table 1633. Array Disk Number

Name

Object ID

Description

Syntax

Access arrayDiskNumber

1.3.6.1.4.1.674.10893.1.20.130.4.1.1

Identifies the instance number of the array disk entry.

Integer

Read-only

Table 1634. Array Disk Name

Name

Object ID

Description

Syntax

Access arrayDiskName

1.3.6.1.4.1.674.10893.1.20.130.4.1.2

Identifies the name of the array disk as represented in Storage Management.

DisplayString

Read-only

Table 1635. Array Disk Vendor

Name

Object ID

Description arrayDiskVendor

1.3.6.1.4.1.674.10893.1.20.130.4.1.3

The array disk's manufacturer's name.

362 Storage Management Group

Table 1635. Array Disk Vendor (continued)

Syntax

Access

DisplayString

Read-only

Table 1636. Array Disk State

Name

Object ID

Description

Syntax

Access arrayDiskState

1.3.6.1.4.1.674.10893.1.20.130.4.1.4

Identifies the current state of the array disk.

Possible states:

0: Unknown

1: Ready - Available for use, but no RAID configuration has been assigned.

2: Failed - Not operational.

3: Online - Operational. RAID configuration has been assigned.

4: Offline - The drive is not available to the RAID controller.

6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk.

7: Recovering - Refers to state of recovering from bad blocks on disks.

11: Removed - Indicates that array disk has been removed.

13: Non-RAID - Indicates that array disk is not a RAID capable disk.

14: Not Ready - Applicable for PCIeSSD devices indicating that the device is in locked state.

15: Resynching - Indicates one of the following types of disk operations: Transform

Type, Reconfiguration, and Check Consistency.

22: Replacing - Indicates copyback operation is in progress.

24: Rebuild

25: No Media - CD-ROM or removable disk has no media.

26: Formatting - In the process of formatting.

28: Diagnostics - Diagnostics are running.

34: Predictive Failure

35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers.

39: Foreign

40: Clear

41: Unsupported

53: Incompatible

56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached read-only state.

Integer

Read-only

Table 1637. Array Disk Severity

Name

Object ID

Description arrayDiskSeverity

1.3.6.1.4.1.674.10893.1.20.130.4.1.5

This entry is obsolete for Storage Management. It was replaced with RollUpStatus and

ComponentStatus for each device.

Storage Management Group 363

Table 1637. Array Disk Severity (continued)

Syntax

Access

Integer

Read-only

Table 1638. Array Disk Product ID

Name

Object ID

Description

Syntax

Access arrayDiskProductID

1.3.6.1.4.1.674.10893.1.20.130.4.1.6

Identifies the model number of the array disk.

DisplayString

Read-only

Table 1639. Array Disk Serial Number

Name

Object ID

Description

Syntax

Access arrayDiskSerialNo

1.3.6.1.4.1.674.10893.1.20.130.4.1.7

Identifies the array disk's unique identification number from the manufacturer.

DisplayString

Read-only

Table 1640. Array Disk Revision

Name

Object ID

Description

Syntax

Access arrayDiskRevision

1.3.6.1.4.1.674.10893.1.20.130.4.1.8

Identifies the firmware version of the array disk.

DisplayString

Read-only

Table 1641. Array Disk Enclosure ID

Name

Object ID

Description

Syntax

Access arrayDiskEnclosureID

1.3.6.1.4.1.674.10893.1.20.130.4.1.9

Identifies the SCSI ID of the enclosure processor to which this array disk belongs.

DisplayString

Read-only

Table 1642. Array Disk Channel

Name arrayDiskChannel

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.4.1.10

Identifies the bus to which this array disk is connected.

Integer

Read-only

Table 1643. Array Disk Length in Megabytes

Name

Object ID arrayDiskLengthInMB

1.3.6.1.4.1.674.10893.1.20.130.4.1.11

364 Storage Management Group

Table 1643. Array Disk Length in Megabytes (continued)

Description

Syntax

Access

Identifies the size in megabytes of the array disk. If this size is 0, it is smaller than a megabyte.

Integer

Read-only

Table 1644. Array Disk Length in Bytes

Name

Object ID

Description

Syntax

Access arrayDiskLengthInBytes

1.3.6.1.4.1.674.10893.1.20.130.4.1.12

Identifies the size of the array disk in bytes that is less than a megabyte. This size plus the arrayDiskLengthInMB is the total size of the array disk.

Integer

Read-only

Table 1645. Array Disk Largest Contiguous Free Space in Megabytes

Name

Object ID

Description

Syntax

Access arrayDiskLargestContiguousFreeSpaceInMB

1.3.6.1.4.1.674.10893.1.20.130.4.1.13

The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte.

Integer

Read-only

Table 1646. Array Disk Largest Contiguous Free Space in Bytes

Name arrayDiskLargestContiguousFreeSpaceInBytes

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.4.1.14

The size of the largest contiguous free space on this array disk in bytes that is less than a megabyte. This size plus the arrayDiskLargestContiguousFreeSpaceInMB is the total size of the largest contiguous free space on the array disk.

Integer

Read-only

Table 1647. Array Disk Target ID

Name

Object ID

Description

Syntax

Access arrayDiskTargetID

1.3.6.1.4.1.674.10893.1.20.130.4.1.15

Identifies the SCSI target ID which this array disk is assigned.

Integer

Read-only

Table 1648. Array Disk LUN ID

Name

Object ID

Description

Syntax

Access arrayDiskLunID

1.3.6.1.4.1.674.10893.1.20.130.4.1.16

Identifies the array disk's logical unit number.

Integer

Read-only

Storage Management Group 365

Table 1649. Array Disk Used Space in Megabytes

Name

Object ID

Description

Syntax

Access arrayDiskUsedSpaceInMB

1.3.6.1.4.1.674.10893.1.20.130.4.1.17

Identifies the amount in megabytes of the used space on the array disk. If this size is 0, it is smaller than a megabyte.

Integer

Read-only

Table 1650. Array Disk Used Space in Bytes

Name

Object ID

Description

Syntax

Access arrayDiskUsedSpaceInBytes

1.3.6.1.4.1.674.10893.1.20.130.4.1.18

Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte. This size plus the arrayDiskUsedSpaceInMB is the total amount of used space on the array disk.

Integer

Read-only

Table 1651. Array Disk Free Space in Megabytes

Name

Object ID

Description

Syntax

Access arrayDiskFreeSpaceInMB

1.3.6.1.4.1.674.10893.1.20.130.4.1.19

Identifies the amount in megabytes of the free space on the array disk. If this size is 0, it is smaller than a megabyte.

Integer

Read-only

Table 1652. Array Disk Free Space in Bytes

Name

Object ID

Description

Syntax

Access arrayDiskFreeSpaceInBytes

1.3.6.1.4.1.674.10893.1.20.130.4.1.20

Identifies the size in bytes of the free space on the array disk that is smaller than a megabyte. This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk.

Integer

Read-only

Table 1653. Array Disk Bus Type

Name

Object ID

Description arrayDiskBusType

1.3.6.1.4.1.674.10893.1.20.130.4.1.21

Identifies the bus type of the array disk.

Possible values:

1: SCSI

2: IDE

3: Fibre Channel

4: SSA

6: USB

7: SATA

366 Storage Management Group

Table 1653. Array Disk Bus Type (continued)

Syntax

Access

8: SAS

9: PCIe

Integer

Read-only

Table 1654. Array Disk Spare State

Name

Object ID

Description arrayDiskSpareState

1.3.6.1.4.1.674.10893.1.20.130.4.1.22

Identifies the status of the array disk as a spare.

Possible states:

1: Disk is a member of a virtual disk

2: Disk is a member of a disk group

3: Disk is a global hot spare

4: Disk is a dedicated hot spare

5: Not a spare

99: Not applicable

Syntax

Access

Integer

Read-only

Table 1655. Array Disk Roll-Up Status

Name

Object ID

Description arrayDiskRollUpStatus

1.3.6.1.4.1.674.10893.1.20.130.4.1.23

Severity of the array disk state. This is the combined status of the array disk and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1656. Array Disk Component Status

Name

Object ID

Description arrayDiskComponentStatus

1.3.6.1.4.1.674.10893.1.20.130.4.1.24

The status of the array disk itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

Storage Management Group 367

Table 1656. Array Disk Component Status (continued)

Syntax

Access

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

DellStatus

Read-only

Table 1657. Array Disk Device Name

Name

Object ID

Description

Syntax

Access arrayDiskDeviceName

1.3.6.1.4.1.674.10893.1.20.130.4.1.25

Identifies the operating system device name for this disk.

DisplayString

Read-only

Table 1658. Array Disk Nexus ID

Name

Object ID

Description

Syntax

Access arrayDiskNexusID

1.3.6.1.4.1.674.10893.1.20.130.4.1.26

Indicates the durable unique ID for this array disk.

DisplayString

Read-only

Table 1659. Array Disk Part Number

Name

Object ID

Description

Syntax

Access arrayDiskPartNumber

1.3.6.1.4.1.674.10893.1.20.130.4.1.27

Indicates the part number of the disk.

DisplayString

Read-only

Table 1660. Array Disk SAS Address

Name

Object ID

Description

Syntax

Access arrayDiskSASAddress

1.3.6.1.4.1.674.10893.1.20.130.4.1.28

Indicates the specified SAS address if this is a SAS disk.

DisplayString

Read-only

Table 1661. Array Disk Negotiated Speed

Name arrayDiskNegotiatedSpeed

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.4.1.29

Indicates the speed at which the drive is actually running in MPS (megabytes per second).

Integer

Read-only

368 Storage Management Group

Table 1662. Array Disk Capable Speed

Name

Object ID

Description

Syntax

Access arrayDiskCapableSpeed

1.3.6.1.4.1.674.10893.1.20.130.4.1.30

Indicates the maximum speed at which the drive is capable of negotiating in MPS

(megabytes per second).

Integer

Read-only

Table 1663. Array Disk Smart Alert Indication

Name

Object ID

Description arrayDiskSmartAlertIndication

1.3.6.1.4.1.674.10893.1.20.130.4.1.31

Indicates whether the disk has received a predictive failure.

Possible values:

1: No - disk has not received a predictive failure alert

2: Yes - disk has received a predictive failure alert

Syntax

Access

Integer

Read-only

Table 1664. Array Disk Manufacture Day

Name

Object ID

Description

Syntax

Access arrayDiskManufactureDay

1.3.6.1.4.1.674.10893.1.20.130.4.1.32

Indicates the day of the week (1=Sunday through 7=Saturday) on which this disk was manufactured.

DisplayString

Read-only

Table 1665. Array Disk Manufacture Week

Name

Object ID

Description

Syntax

Access arrayDiskManufactureWeek

1.3.6.1.4.1.674.10893.1.20.130.4.1.33

Indicates the week (1 through 53) in which this disk was manufactured.

DisplayString

Read-only

Table 1666. Array Disk Manufacture Year

Name

Object ID

Description

Syntax

Access arrayDiskManufactureYear

1.3.6.1.4.1.674.10893.1.20.130.4.1.34

Indicates the four-digit year in which this disk was manufactured.

DisplayString

Read-only

Table 1667. Array Disk Media Type

Name arrayDiskMediaType

Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35

Storage Management Group 369

Table 1667. Array Disk Media Type (continued)

Description The Media type of the array disk.

Possible Values:

1:unknown

2:hdd

3:ssd

Syntax

Access

INTEGER

Read-only

Table 1668. Array Disk Dell Certified

Name arrayDiskDellCertified

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.4.1.36

Indicates if array disk is certified by Dell. Value: 1 - Certified, 0 - Not Certified, 99 -

Unknown

Integer

Read-only

Table 1669. Array Disk Alta Vendor Id

Name

Object ID

Description

Syntax

Access arrayDiskAltaVendorId

1.3.6.1.4.1.674.10893.1.20.130.4.1.37

Provides vendor information for Alta interposer.

Octet String

Read-only

Table 1670. Array Disk Alta Product Id

Name

Object ID

Description

Syntax

Access arrayDiskAltaProductId

1.3.6.1.4.1.674.10893.1.20.130.4.1.38

Provides product ID for Alta interposer.

Octet String

Read-only

Table 1671. Array Disk Alta Revision Id

Name

Object ID

Description

Syntax

Access arrayDiskAltaRevisionId

1.3.6.1.4.1.674.10893.1.20.130.4.1.39

Provides revision ID for Alta interposer.

Octet String

Read-only

Table 1672. Array Disk Encryption Capable

Name

Object ID

Description arrayDiskEncryptionCapable

1.3.6.1.4.1.674.10893.1.20.130.4.1.40

Indicates if physical disk is encryption capable. Value: 1 - Capable, 0 - Not Capable, 99 -

Not Applicable

370 Storage Management Group

Table 1672. Array Disk Encryption Capable (continued)

Syntax

Access

Integer

Read-only

Table 1673. Array Disk Encrypted

Name

Object ID

Description

Syntax

Access arrayDiskEncrypted

1.3.6.1.4.1.674.10893.1.20.130.4.1.41

Indicates if the physical disk has encryption enabled. Value: 1 - Yes, 0 - No, 99 - Not

Applicable

Integer

Read-only

Table 1674. Array Disk Power State

Name

Object ID

Description

Syntax

Access arrayDiskPowerState

1.3.6.1.4.1.674.10893.1.20.130.4.1.42

Indicates power state of a physical drive. Value: 0 - Spun up, 1- Spun down, 255 -

Transition, 99 - Not Applicable

Integer

Read-only

Table 1675. Array Disk Drive Write Cache

Name

Object ID

Description

Syntax

Access arrayDiskDriveWriteCache

1.3.6.1.4.1.674.10893.1.20.130.4.1.43

Indicates drive write cache capability for PCIe SSD devices. Value: 1 - Enabled, 0 -

Disabled, 99 - Undetermined/NotApplicable

Integer

Read-only

Table 1676. Array Disk Model Number

Name

Object ID

Description

Syntax

Access arrayDiskModelNumber

1.3.6.1.4.1.674.10893.1.20.130.4.1.44

Provides PCIe SSD device model number.

DisplayString

Read-only

Table 1677. Array Disk Life Remaining

Name

Object ID

Description

Syntax

Access arrayDiskLifeRemaining

1.3.6.1.4.1.674.10893.1.20.130.4.1.45

Provides PCIe SSD device life remaining in percentage. Value: 0..100, 999 -

Undetermined/Not Applicable

INTEGER

Read-only

Storage Management Group 371

Table 1678. Array Disk Driver Version

Name

Object ID

Description

Syntax

Access arrayDiskDriverVersion

1.3.6.1.4.1.674.10893.1.20.130.4.1.46

Provides PCIe SSD device driver version.

INTEGER

Read-only

Table 1679. Array Disk Device Life Status

Name

Object ID

Description arrayDiskDeviceLifeStatus

1.3.6.1.4.1.674.10893.1.20.130.4.1.47

Provides PCIe SSD device life status.

Possible Values:

-1: Not Available / Not Applicable

1: Drive Health Good

2: Approaching Warranty Coverage Expiry

3: Warranty Coverage Expired

4: Approaching Read Only

5: Read Only

Syntax

Access

INTEGER

Read-only

Table 1680. Array Disk Read Only

Name

Object ID

Description arrayDiskReadOnly

1.3.6.1.4.1.674.10893.1.20.130.4.1.48

Provides the read only attribute for PCIe SSD.

Possible Values:

Yes, No, Not Applicable

Syntax

Access

DisplayString

Read-only

Table 1681. Array Disk Remaining Rated Write Endurance

Name

Object ID

Description arrayDiskRemainingRatedWriteEndurance

1.3.6.1.4.1.674.10893.1.20.130.4.1.49

Provides the remaining rated write endurance for SAS/SATA SSD device.

Possible Values:

0-100% : Not Available / Not Applicable

Syntax

Access

DisplayString

Read-only

Table 1682. Array Disk Sector Size

Name

Object ID arrayDiskSectorSize

1.3.6.1.4.1.674.10893.1.20.130.4.1.50

372 Storage Management Group

Table 1682. Array Disk Sector Size (continued)

Description Provides the information regarding sector size of the array disk.

Possible Values:

512 or 4096

Syntax

Access

INTEGER

Read-only

Table 1683. Array Disk PI Capable

Name

Object ID

Description arrayDiskPICapable

1.3.6.1.4.1.674.10893.1.20.130.4.1.51

Provides the information regarding T10 PI capability of array disk.

Possible Values:

0 : T10 PI incapable or 1 : T10 PI capable

Syntax

Access

INTEGER

Read-only

Table 1684. Array Disk Max Link Width

Name

Object ID

Description arrayDiskMaxLinkWidth

1.3.6.1.4.1.674.10893.1.20.130.4.1.52

Provides the information regarding Max Link Width of array disk.

Possible Values:

0 – 8

Syntax

Access

INTEGER

Read-only

Table 1685. Array Disk Negotiated Link Width

Name arrayDiskNegotiatedLinkWidth

Object ID

Description

1.3.6.1.4.1.674.10893.1.20.130.4.1.53

Provides the information regarding Negotiated Link Width of array disk.

Possible Values:

0 – 8

Syntax

Access

INTEGER

Read-only

Table 1686. Non-RAID Disk Cache Policy

Name

Object ID

Description nonRAIDdiskCachePolicy

1.3.6.1.4.1.674.10893.1.20.130.4.1.54

Displays the current disk write cache policy of the Non-RAID disk.

Possible Values:

Enabled - Disabled

Syntax

Access

DisplayString

Read-only

Storage Management Group 373

Table 1687. Array Disk Cache Policy

Name

Object ID

Description arraydiskCachePolicy

1.3.6.1.4.1.674.10893.1.20.130.4.1.55

Displays the current disk write cache policy of the array disk.

Possible Values:

Enabled - Disabled - Default

Syntax

Access

DisplayString

Read-only

Table 1688. Array Disk ISE Capable

Name

Object ID

Description

Syntax

Access arraydiskISECapable

1.3.6.1.4.1.674.10893.1.20.130.4.1.56

A boolean value decepting if the disk is Instant Secure Erase Capable or not.

INTEGER

Read-only

Array Disk Enclosure Connection Table

This table describes the connections among array disks, their enclosure, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all the object properties can be found.

NOTE: Only array disks that are part of an enclosure are listed in this table. Backplanes are considered enclosures by

Storage Management.

The following object sets up the Array Disk Enclosure Connection Table.

Table 1689. Array Disk Enclosure Connection Table

Name

Object ID

Description

Syntax

Access arrayDiskEnclosureConnectionTable

1.3.6.1.4.1.674.10893.1.20.130.5

Defines the array disk enclosure connection table.

SEQUENCE OF ArrayDiskEnclosureConnectionEntry

Not accessible

Table 1690. Array Disk Enclosure Connection Entry

Name

Object ID

Description

Syntax

Access

Index arrayDiskEnclosureConnectionEntry

1.3.6.1.4.1.674.10893.1.20.130.5.1

Defines the array disk enclosure connection table entry.

Syntax ArrayDiskEnclosureConnectionEntry

Not accessible

Index arrayDiskEnclosureConnectionNumber

Table 1691. Array Disk Enclosure Connection Number

Name

Object ID

Description arrayDiskEnclosureConnectionNumber

1.3.6.1.4.1.674.10893.1.20.130.5.1.1

Identifies the instance number of the array disk enclosure connection entry.

374 Storage Management Group

Table 1691. Array Disk Enclosure Connection Number (continued)

Syntax

Access

Integer

Read-only

Table 1692. Array Disk Enclosure Connection Array Disk Name

Name

Object ID

Description

Syntax

Access arrayDiskEnclosureConnectionArrayDiskName

1.3.6.1.4.1.674.10893.1.20.130.5.1.2

Identifies the name of the array disk in this connection as represented in Storage

Management.

DisplayString

Read-only

Table 1693. Array Disk Enclosure Connection Array Disk Number

Name

Object ID

Description

Syntax

Access arrayDiskEnclosureConnectionArrayDiskNumber

1.3.6.1.4.1.674.10893.1.20.130.5.1.3

Identifies the instance number of the array disk in the arrayDiskTable in this connection.

Integer

Read-only

Table 1694. Array Disk Enclosure Connection Enclosure Name

Name

Object ID

Description

Syntax

Access arrayDiskEnclosureConnectionEnclosureName

1.3.6.1.4.1.674.10893.1.20.130.5.1.4

Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs.

DisplayString

Read-only

Table 1695. Array Disk Enclosure Connection Enclosure Number

Name

Object ID

Description

Syntax

Access arrayDiskEnclosureConnectionEnclosureNumber

1.3.6.1.4.1.674.10893.1.20.130.5.1.5

Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs.

Integer

Read-only

Table 1696. Array Disk Enclosure Connection Controller Name

Name

Object ID

Description

Syntax

Access arrayDiskEnclosureConnectionControllerName

1.3.6.1.4.1.674.10893.1.20.130.5.1.6

Identifies the name of the controller as represented in Storage Management to which this array disk is connected.

DisplayString

Read-only

Storage Management Group 375

Table 1697. Array Disk Enclosure Connection Controller Number

Name

Object ID

Description

Syntax

Access arrayDiskEnclosureConnectionControllerNumber

1.3.6.1.4.1.674.10893.1.20.130.5.1.7

Identifies the instance number in the controller, table of the controller to which this array disk is connected.

Integer

Read-only

Array Disk Channel Connection Table

This table describes the connections between array disks, their channel, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all the object properties can be found.

NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by

Storage Management.

The following object sets up the Array Disk Channel Connection Table.

Table 1698. Array Disk Channel Connection Table

Name arrayDiskChannelConnectionTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.6

Defines the array disk channel connection table.

SEQUENCE OF ArrayDiskChannelConnectionEntry

Not accessible

Table 1699. Array Disk Channel Connection Entry

Name

Object ID

Description

Syntax

Access

Index arrayDiskChannelConnectionEntry

1.3.6.1.4.1.674.10893.1.20.130.6.1

Defines the array disk channel connection table entry.

ArrayDiskChannelConnectionEntry

Not accessible arrayDiskEnclosureConnectionNumber

Table 1700. Array Disk Channel Connection Number

Name arrayDiskChannelConnectionNumber

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.6.1.1

Identifies the instance number of the array disk channel connection entry.

Integer

Read-only

Table 1701. Array Disk Channel Connection Array Disk Name

Name

Object ID arrayDiskChannelConnectionArrayDiskName

1.3.6.1.4.1.674.10893.1.20.130.6.1.2

376 Storage Management Group

Table 1701. Array Disk Channel Connection Array Disk Name (continued)

Description

Syntax

Access

Identifies the name of the array disk in this connection as represented in Storage

Management.

DisplayString

Read-only

Table 1702. Array Disk Channel Connection Array Disk Number

Name

Object ID

Description

Syntax

Access arrayDiskChannelConnectionArrayDiskNumber

1.3.6.1.4.1.674.10893.1.20.130.6.1.3

Identifies the instance number of the array disk in the arrayDiskTable in this connection.

Integer

Read-only

Table 1703. Array Disk Channel Connection Channel Name

Name

Object ID

Description

Syntax

Access arrayDiskChannelConnectionChannelName

1.3.6.1.4.1.674.10893.1.20.130.6.1.4

Identifies the name of the channel as represented in Storage Management to which is array disk is connected.

DisplayString

Read-only

Table 1704. Array Disk Channel Connection Channel Number

Name arrayDiskChannelConnectionChannelNumber

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.6.1.5

Identifies the instance number of the channel in the channelTable to which this array disk is connected.

Integer

Read-only

Table 1705. Array Disk Channel Connection Controller Name

Name arrayDiskChannelConnectionControllerName

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.6.1.6

Identifies the name of the controller as represented in Storage Management to which this array disk is connected.

DisplayString

Read-only

Table 1706. Array Disk Channel Connection Controller Number

Name arrayDiskChannelConnectionControllerNumber

Storage Management Group 377

Table 1706. Array Disk Channel Connection Controller Number (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.6.1.7

Identifies the instance number in the controllerTable of the controller to which this array disk is connected.

Integer

Read-only

Fan Table

This table describes available properties for each fan on the managed system.

The following object sets up the Fan Table.

Table 1707. Fan Table

Name

Object ID

Description

Syntax

Access fanTable

1.3.6.1.4.1.674.10893.1.20.130.7

Defines the fan table.

SEQUENCE OF FanEntry

Not accessible

Table 1708. Fan Entry

Name

Object ID

Description

Syntax

Access

Index

Table 1709. Fan Number

Name

Object ID

Description

Syntax

Access

Table 1710. Fan Name

Name

Object ID

Description

Syntax

Access

Table 1711. Fan Vendor

Name fanEntry

1.3.6.1.4.1.674.10893.1.20.130.7.1

Defines the fan table entry.

FanEntry

Not accessible fanNumber fanNumber

1.3.6.1.4.1.674.10893.1.20.130.7.1.1

Identifies the instance number of the fan entry.

Integer

Read-only fanName

1.3.6.1.4.1.674.10893.1.20.130.7.1.2

Identifies the fan's name as represented in Storage Management.

DisplayString

Read-only fanVendor

378 Storage Management Group

Table 1711. Fan Vendor (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.7.1.3

Identifies the fan's (re)seller's name.

DisplayString

Read-only

Table 1712. Fan State

Name

Object ID

Description

Syntax

Access fanState

1.3.6.1.4.1.674.10893.1.20.130.7.1.4

Identifies the current state of the fan.

Possible states:

0: Unknown

1: Ready

2: Failed

3: Online

4: Offline

6: Degraded

21: Missing

Integer

Read-only

Table 1713. Fan Severity

Name

Object ID

Description

Syntax

Access fanSeverity

1.3.6.1.4.1.674.10893.1.20.130.7.1.5

This entry is obsolete for Storage Management. It was replaced with RollUpStatus and

ComponentStatus for each device.

Integer

Read-only

Table 1714. Fan Probe Unit

Name

Object ID

Description

Syntax

Access fanProbeUnit

1.3.6.1.4.1.674.10893.1.20.130.7.1.6

This entry is obsolete for Storage Services.

DisplayString

Read-only

Table 1715. Fan Probe Minimum Warning

Name

Object ID

Description

Syntax

Access fanProbeMinimumWarning

1.3.6.1.4.1.674.10893.1.20.130.7.1.7

This entry is obsolete. This setting is not supported by fans managed under Storage

Management.

DisplayString

Read-only

Storage Management Group 379

Table 1716. Fan Probe Minimum Critical

Name

Object ID

Description

Syntax

Access fanProbeMinimumCritical

1.3.6.1.4.1.674.10893.1.20.130.7.1.8

This entry is obsolete. This setting is not supported by fans managed under Storage

Management.

DisplayString

Read-only

Table 1717. Fan Probe Maximum Warning

Name

Object ID

Description

Syntax

Access fanProbeMaximumWarning

1.3.6.1.4.1.674.10893.1.20.130.7.1.9

This entry is obsolete. This setting is not supported by fans managed under Storage

Management.

DisplayString

Read-only

Table 1718. Fan Probe Maximum Critical

Name

Object ID

Description

Syntax

Access fanProbeMaximumCritical

1.3.6.1.4.1.674.10893.1.20.130.7.1.10

This entry is obsolete. This setting is not supported by fans managed under Storage

Management.

DisplayString

Read-only

Table 1719. Fan Probe Current Value

Name

Object ID

Description

Syntax

Access fanProbeCurrValue

1.3.6.1.4.1.674.10893.1.20.130.7.1.11

Identifies the current speed of the fan.

DisplayString

Read-only

Table 1720. Fan1 Part Number

Name

Object ID

Description

Syntax

Access fan1PartNumber

1.3.6.1.4.1.674.10893.1.20.130.7.1.12

Identifies the part number of the fan in the enclosure.

DisplayString

Read-only

Table 1721. Fan 2 Part Number

Name

Object ID

Description

Syntax fan2PartNumber

1.3.6.1.4.1.674.10893.1.20.130.7.1.13

This entry is obsolete. This setting is not supported by fans managed under Storage

Management.

DisplayString

380 Storage Management Group

Table 1721. Fan 2 Part Number (continued)

Access Read-only

Table 1722. Fan Roll-Up Status

Name

Object ID

Description fanRollUpStatus

1.3.6.1.4.1.674.10893.1.20.130.7.1.14

Severity of the fan state. This is the combined status of the fan and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1723. Fan Component Status

Name

Object ID

Description fanComponentStatus

1.3.6.1.4.1.674.10893.1.20.130.7.1.15

The status of the fan itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1724. Fan Nexus ID

Name

Object ID

Description

Syntax

Access

Table 1725. Fan Revision

Name

Object ID

Description

Syntax fanNexusID

1.3.6.1.4.1.674.10893.1.20.130.7.1.16

Durable unique ID for this fan.

DisplayString

Read-only fanRevision

1.3.6.1.4.1.674.10893.1.20.130.7.1.17

Indicates the revision number of the fan in the enclosure.

DisplayString

Storage Management Group 381

Table 1725. Fan Revision (continued)

Access Read-only

Fan Connection Table

This table describes the connection between each fan on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table.

The following object sets up the Fan Connection Table.

Table 1726. Fan Connection Table

Name

Object ID

Description

Syntax

Access fanConnectionTable fanConnectionTable

Defines the fan connection table.

SEQUENCE OF FanConnectionEntry

Not accessible

Table 1727. Fan Connection Entry

Name

Object ID

Description

Syntax

Access

Index fanConnectionEntry

1.3.6.1.4.1.674.10893.1.20.130.8.1

Defines the fan connection table entry.

FanConnectionEntry

Not accessible fanConnectionNumber

Table 1728. Fan Connection Number

Name

Object ID

Description

Syntax

Access fanConnectionNumber

1.3.6.1.4.1.674.10893.1.20.130.8.1.1

Identifies the instance number of the fan connection entry.

Integer

Read-only

Table 1729. Fan Connection Fan Name

Name

Object ID

Description

Syntax

Access fanConnectionFanName

1.3.6.1.4.1.674.10893.1.20.130.8.1.2

Identifies the name of the fan in this connection as represented in Storage

Management.

DisplayString

Read-only

Table 1730. Fan Connection Fan Number

Name

Object ID

Description

Syntax fanConnectionFanNumber

1.3.6.1.4.1.674.10893.1.20.130.8.1.3

Identifies the instance number of the fan in the fanTable in the connection.

Integer

382 Storage Management Group

Table 1730. Fan Connection Fan Number (continued)

Access Read-only

Table 1731. Fan Connection Enclosure Name

Name

Object ID

Description

Syntax

Access fanConnectionEnclosureName

1.3.6.1.4.1.674.10893.1.20.130.8.1.4

Identifies the name of the enclosure as represented in Storage Management to which this fan belongs.

DisplayString

Read-only

Table 1732. Fan Connection Enclosure Number

Name

Object ID

Description

Syntax

Access fanConnectionEnclosureNumber

1.3.6.1.4.1.674.10893.1.20.130.8.1.5

Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs.

Integer

Read-only

Power Supply Table

This table describes available properties for each power supply on the managed system.

The following object sets up the Power Supply Table.

Table 1733. Power Supply Table

Name

Object ID

Description

Syntax

Access powerSupplyTable

1.3.6.1.4.1.674.10893.1.20.130.9

Defines the power supply table.

SEQUENCE OF PowerSupplyEntry

Not accessible

Table 1734. Power Supply Entry

Name

Object ID

Description

Syntax

Access

Index powerSupplyEntry

1.3.6.1.4.1.674.10893.1.20.130.9.1

Defines the power supply table entry.

PowerSupplyEntry

Not accessible powerSupplyNumber

Table 1735. Power Supply Number

Name

Object ID

Description

Syntax powerSupplyNumber

1.3.6.1.4.1.674.10893.1.20.130.9.1.1

Identifies the instance number of the power supply entry.

Integer

Storage Management Group 383

Table 1735. Power Supply Number (continued)

Access Read-only

Table 1736. Power Supply Name

Name

Object ID

Description

Syntax

Access powerSupplyName

1.3.6.1.4.1.674.10893.1.20.130.9.1.2

Identifies the power supply's name as represented in Storage Management.

DisplayString

Read-only

Table 1737. Power Supply Vendor

Name

Object ID

Description

Syntax

Access powerSupplyVendor

1.3.6.1.4.1.674.10893.1.20.130.9.1.3

Identifies the power supply's (re)seller's name.

DisplayString

Read-only

Table 1738. Power Supply State

Name powerSupplyState

Object ID

Description

1.3.6.1.4.1.674.10893.1.20.130.9.1.4

Identifies the current state of the power supply.

Possible states:

0: Unknown

1: Ready

2: Failed

5: Not Installed

6: Degraded

11: Removed

Syntax

Access

Integer

Read-only

Table 1739. Power Supply Severity

Name

Object ID

Description

Syntax

Access powerSupplySeverity

1.3.6.1.4.1.674.10893.1.20.130.9.1.5

This entry is obsolete for Storage Management. It was replaced with RollUpStatus and

ComponentStatus for each device.

Integer

Read-only

Table 1740. Power Supply 1 Part Number

Name

Object ID

Description powerSupply1PartNumber

1.3.6.1.4.1.674.10893.1.20.130.9.1.6

Identifies the part number of the power supply of the enclosure.

384 Storage Management Group

Table 1740. Power Supply 1 Part Number (continued)

Syntax

Access

DisplayString

Read-only

Table 1741. Power Supply 2 Part Number

Name

Object ID

Description

Syntax

Access powerSupply2PartNumber

1.3.6.1.4.1.674.10893.1.20.130.9.1.7

This entry is obsolete. This setting is not supported by power supplies managed under

Storage Management

DisplayString

Read-only

Table 1742. Power Supply Roll-Up Status

Name

Object ID

Description powerSupplyRollUpStatus

1.3.6.1.4.1.674.10893.1.20.130.9.1.8

Severity of the power supply state. This is the combined status of the power supply and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1743. Power Supply Component Status

Name

Object ID

Description powerSupplyComponentStatus

1.3.6.1.4.1.674.10893.1.20.130.9.1.9

Severity of the power supply state. This is the combined status of the power supply and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1744. Power Supply NexusID

Name powerSupplyNexusID

Storage Management Group 385

Table 1744. Power Supply NexusID (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.9.1.10

Durable unique ID for this power supply.

DisplayString

Read-only

Table 1745. Power Supply Revision

Name

Object ID

Description

Syntax

Access powerSupplyRevision

1.3.6.1.4.1.674.10893.1.20.130.9.1.11

Indicates the revision number of the power supply in the enclosure.

DisplayString

Read-only

Power Supply Connection Table

This table describes the connection between each power supply on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table.

The following object sets up the Power Supply Connection Table.

Table 1746. Power Supply Connection Table

Name

Object ID

Description

Syntax

Access powerSupplyConnectionTable

1.3.6.1.4.1.674.10893.1.20.130.10

Defines the power supply connection table.

SEQUENCE OF PowerSupplyConnectionEntry

Not accessible

Table 1747. Power Supply Connection Entry

Name

Object ID

Description

Syntax

Access

Index powerSupplyConnectionEntry

1.3.6.1.4.1.674.10893.1.20.130.10.1

Defines the power supply connection table entry.

PowerSupplyConnectionEntry

Not accessible powerSupplyConnectionNumber

Table 1748. Power Supply Connection Number

Name

Object ID

Description

Syntax

Access powerSupplyConnectionNumber

1.3.6.1.4.1.674.10893.1.20.130.10.1.1

Identifies the instance number of the power supply connection entry.

Integer

Read-only

Table 1749. Power Supply Connection Power Supply Name

Name powerSupplyConnectionPowerSupplyName

386 Storage Management Group

Table 1749. Power Supply Connection Power Supply Name (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.10.1.2

Identifies the name of the power supply in this connection as represented in Storage

Management.

DisplayString

Read-only

Table 1750. Power Supply Connection Power Supply Number

Name

Object ID

Description

Syntax

Access powerSupplyConnectionPowerSupplyNumber

1.3.6.1.4.1.674.10893.1.20.130.10.1.3

Identifies the instance number of the power supply in the powerSupplyTable in the connection.

Integer

Read-only

Table 1751. Power Supply Connection Enclosure Name

Name

Object ID

Description

Syntax

Access powerSupplyConnectionEnclosureName

1.3.6.1.4.1.674.10893.1.20.130.10.1.4

Identifies the name of the enclosure as represented in Storage Management to which this power supply belongs.

DisplayString

Read-only

Table 1752. Power Supply Connection Enclosure Number

Name

Object ID

Description

Syntax

Access powerSupplyConnectionEnclosureNumber

1.3.6.1.4.1.674.10893.1.20.130.10.1.5

Identifies the instance number of the enclosure in the enclosureTable to which this power supply belongs.

Integer

Read-only

Table 1753. Power Supply Connection Firmware Version

Name

Object ID

Description powerSupplyConnectionFirmwareVersion

1.3.6.1.4.1.674.10893.1.20.130.10.1.6

Displays power supply connection firmware version.

NOTE:

Syntax

Access

Available firmware version 1.04 and later.

DisplayString

Read-only

Temperature Probe Table

This table describes available properties for each temperature probe on the managed system.

The following object sets up the Temperature Probe Table.

Storage Management Group 387

Table 1754. Temperature Probe Table

Name

Object ID

Description temperatureProbeTable

1.3.6.1.4.1.674.10893.1.20.130.11

A table of managed temperature probes. The number of entries is related to the number of temperature probes discovered in the system. The maximum number of entries is implementation dependent.

NOTE:

Syntax

Access

The properties in this table may not be applicable to all entries.

SEQUENCE OF TemperatureProbeEntry

Not accessible

Table 1755. Temperature Probe Entry

Name

Object ID

Description

Syntax

Access

Index temperatureProbeEntry

1.3.6.1.4.1.674.10893.1.20.130.11.1

An entry in the Temperature Probe Table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.

TemperatureProbeEntry

Not accessible

TemperatureProbeNumber

Table 1756. Temperature Probe Number

Name

Object ID

Description

Syntax

Access temperatureProbeNumber

1.3.6.1.4.1.674.10893.1.20.130.11.1.1

Identifies the instance number of the temperature probe entry.

Integer

Read-only

Table 1757. Temperature Probe Name

Name

Object ID

Description

Syntax

Access temperatureProbeName

1.3.6.1.4.1.674.10893.1.20.130.11.1.2

Identifies the temperature probe's name as represented in Storage Management.

DisplayString

Read-only

Table 1758. Temperature Probe Vendor

Name

Object ID

Description

Syntax

Access temperatureProbeVendor

1.3.6.1.4.1.674.10893.1.20.130.11.1.3

Identifies the temperature probe's (re)seller's name.

DisplayString

Read-only

Table 1759. Temperature Probe State

Name

Object ID temperatureProbeState

1.3.6.1.4.1.674.10893.1.20.130.11.1.4

388 Storage Management Group

Table 1759. Temperature Probe State (continued)

Description Identifies the current state of the temperature probe.

Possible states:

0: Unknown

1: Ready

2: Failed (Minimum Failure Threshold Exceeded, Maximum Failure Threshold Exceeded)

4: Offline

6: Degraded (Minimum Warning Threshold Exceeded, Maximum Warning Threshold

Exceeded)

9: Inactive

21: Missing

Syntax

Access

Integer

Read-only

Table 1760. Temperature Probe Severity

Name

Object ID

Description

Syntax

Access temperatureProbeSeverity

1.3.6.1.4.1.674.10893.1.20.130.11.1.5

This entry is obsolete for Storage Management. It was replaced with RollUpStatus and

ComponentStatus for each device.

Integer

Read-only

Table 1761. Temperature Probe Unit

Name

Object ID

Description

Syntax

Access temperatureProbeUnit

1.3.6.1.4.1.674.10893.1.20.130.11.1.6

The units that are used to display temperatures for the temperature probe.

DisplayString

Read-only

Table 1762. Temperature Probe Minimum Warning

Name

Object ID

Description

Syntax

Access temperatureProbeMinWarning

1.3.6.1.4.1.674.10893.1.20.130.11.1.7

Identifies the minimum temperature that forces the probe into a warning state.

Integer

Read-only

Table 1763. Temperature Probe Minimum Critical

Name

Object ID

Description

Syntax

Access temperatureProbeMinCritical

1.3.6.1.4.1.674.10893.1.20.130.11.1.8

Identifies the minimum temperature that forces the probe into an error state.

Integer

Read-only

Storage Management Group 389

Table 1764. Temperature Probe Maximum Warning

Name

Object ID

Description

Syntax

Access temperatureProbeMaxWarning

1.3.6.1.4.1.674.10893.1.20.130.11.1.9

Identifies the maximum temperature that forces the probe into a warning state.

Integer

Read-only

Table 1765. Temperature Probe Maximum Critical

Name

Object ID

Description

Syntax

Access temperatureProbeMaxCritical

1.3.6.1.4.1.674.10893.1.20.130.11.1.10

Identifies the maximum temperature that forces the probe into an error state.

Integer

Read-only

Table 1766. Temperature Probe Current Value

Name

Object ID

Description

Syntax

Access temperatureProbeCurValue

1.3.6.1.4.1.674.10893.1.20.130.11.1.11

Identifies the current temperature of this probe.

Integer

Read-only

Table 1767. Temperature Probe Roll-Up Status

Name

Object ID

Description temperatureProbeRollUpStatus

1.3.6.1.4.1.674.10893.1.20.130.11.1.12

Severity of the temperature probe state. This is the combined status of the temperature probe and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1768. Temperature Probe Component Status

Name

Object ID

Description temperatureProbeComponentStatus

1.3.6.1.4.1.674.10893.1.20.130.11.1.13

The status of the temperature probe itself without the propagation of any contained component status.

Possible values:

1: Other

390 Storage Management Group

Table 1768. Temperature Probe Component Status (continued)

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1769. Temperature Probe Nexus ID

Name

Object ID

Description

Syntax

Access temperatureProbeNexusID

1.3.6.1.4.1.674.10893.1.20.130.11.1.14

Durable unique ID for this temperature probe.

DisplayString

Read-only

Temperature Probe Connection Table

This table describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table.

The following object sets up the Temperature Probe Connection Table.

Table 1770. Temperature Probe Connection Table

Name

Object ID

Description

Syntax

Access temperatureConnectionTable

1.3.6.1.4.1.674.10893.1.20.130.12

Defines the temperature probe connection table.

SEQUENCE OF TemperatureConnectionEntry

Not accessible

Table 1771. Temperature Probe Connection Entry

Name

Object ID

Description

Syntax

Access

Index temperatureConnectionEntry

1.3.6.1.4.1.674.10893.1.20.130.12.1

Defines the temperature probe connection table entry.

TemperatureConnectionEntry

Not accessible temperatureConnectionNumber

Table 1772. Temperature Probe Connection Number

Name

Object ID

Description

Syntax

Access temperatureConnectionNumber

1.3.6.1.4.1.674.10893.1.20.130.12.1.1

Identifies the instance number of the temperature probe connection entry.

Integer

Read-only

Storage Management Group 391

Table 1773. Temperature Probe Connection Temperature Probe Name

Name

Object ID

Description

Syntax

Access temperatureConnectionTemperatureName

1.3.6.1.4.1.674.10893.1.20.130.12.1.2

Identifies the name of the temperature probe in this connection as represented in

Storage Management.

DisplayString

Read-only

Table 1774. Temperature Probe Connection Temperature Probe Number

Name

Object ID

Description

Syntax

Access temperatureConnectionTemperatureNumber

1.3.6.1.4.1.674.10893.1.20.130.12.1.3

Identifies the instance number in the temperatureTable of the temperature probe in this connection.

Integer

Read-only

Table 1775. Temperature Probe Connection Enclosure Name

Name

Object ID

Description

Syntax

Access temperatureConnectionEnclosureName

1.3.6.1.4.1.674.10893.1.20.130.12.1.4

Identifies the name of the enclosure as represented in Storage Management to which this temperature probe belongs.

DisplayString

Read-only

Table 1776. Temperature Probe Connection Enclosure Number

Name

Object ID

Description

Syntax

Access temperatureConnectionEnclosureNumber

1.3.6.1.4.1.674.10893.1.20.130.12.1.5

Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe belongs.

Integer

Read-only

Enclosure Management Module Table

This table describes available properties for each enclosure management module on the managed system.

The following object sets up the Enclosure Management Module Table.

Table 1777. Enclosure Management Module Table

Name

Object ID

Description

Syntax

Access enclosureManagementModuleTable

1.3.6.1.4.1.674.10893.1.20.130.13

Defines the enclosure management module table.

SEQUENCE OF EnclosureManagementModuleEntry

Not accessible

392 Storage Management Group

Table 1778. Enclosure Management Module Entry

Name

Object ID

Description

Syntax

Access

Index

EnclosureManagementModuleEntry

1.3.6.1.4.1.674.10893.1.20.130.13.1

Defines the enclosure management module table entry.

EnclosureManagementModuleEntry

Not accessible enclosureManagementModuleNumber

Table 1779. Enclosure Management Module Number

Name

Object ID

Description

Syntax

Access enclosureManagementModuleNumber

1.3.6.1.4.1.674.10893.1.20.130.13.1.1

Identifies the instance number of the enclosure management module entry.

Integer

Read-only

Table 1780. Enclosure Management Module Name

Name

Object ID

Description

Syntax

Access enclosureManagementModuleName

1.3.6.1.4.1.674.10893.1.20.130.13.1.2

Identifies the enclosure management module's name as represented in Storage

Management.

DisplayString

Read-only

Table 1781. Enclosure Management Module Vendor

Name

Object ID

Description

Syntax

Access enclosureManagementModuleVendor

1.3.6.1.4.1.674.10893.1.20.130.13.1.3

Identifies the enclosure management module's (re)seller's name.

DisplayString

Read-only

Table 1782. Enclosure Management Module State

Name

Object ID

Description enclosureManagementModuleState

1.3.6.1.4.1.674.10893.1.20.130.13.1.4

Identifies the current state of the enclosure management module.

Possible states:

0: Unknown

1: Ready

2: Failed

3: Online

4: Offline

5: Not Installed

6: Degraded

21: Missing

Storage Management Group 393

Table 1782. Enclosure Management Module State (continued)

Syntax

Access

Integer

Read-only

Table 1783. Enclosure Management Module Severity

Name

Object ID

Description

Syntax

Access enclosureManagementModuleSeverity

1.3.6.1.4.1.674.10893.1.20.130.13.1.5

This entry is obsolete for Storage Management. It was replaced with RollUpStatus and

ComponentStatus for each device.

Integer

Read-only

Table 1784. Enclosure Management Module Part Number

Name

Object ID

Description

Syntax

Access enclosureManagementModulePartNumber

1.3.6.1.4.1.674.10893.1.20.130.13.1.6

Identifies the part number of the enclosure memory module.

Display String

Read-only

Table 1785. Enclosure Management Module Type

Name

Object ID

Description enclosureManagementModuleType

1.3.6.1.4.1.674.10893.1.20.130.13.1.7

Identifies the type of the enclosure management module.

Possible values:

0: Unknown

1: EMM

2: Termination Card

Syntax

Access

Integer

Read-only

Table 1786. Enclosure Management Module Firmware Version

Name

Object ID

Description

Syntax

Access enclosureManagementModuleFWVersion

1.3.6.1.4.1.674.10893.1.20.130.13.1.8

Identifies the firmware version of the enclosure memory module.

DisplayString

Read-only

Table 1787. Enclosure Management Module Maximum Speed

Name enclosureManagementModuleMaxSpeed

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.13.1.9

Identifies the maximum bus speed of the enclosure management module.

DisplayString

Read-only

394 Storage Management Group

Table 1788. Enclosure Management Module Roll-Up Status

Name

Object ID

Description enclosureManagementModuleRollUpStatus

1.3.6.1.4.1.674.10893.1.20.130.13.1.10

Severity of the enclosure management module state. This is the combined status of the

EMM and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1789. Enclosure Management Module Component Status

Name

Object ID

Description enclosureManagementModuleComponentStatus

1.3.6.1.4.1.674.10893.1.20.130.13.1.11

The status of the enclosure management module itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1790. Enclosure Management Module Nexus ID

Name enclosureManagementModuleNexusID

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.13.1.12

Durable unique ID for this EMM.

DisplayString

Read-only

Table 1791. Enclosure Management Module Revision

Name

Object ID

Description

Syntax

Access enclosureManagementModuleRevision

1.3.6.1.4.1.674.10893.1.20.130.13.1.13

Identifies the revision number of the enclosure management module.

DisplayString

Read-only

Storage Management Group 395

Enclosure Management Module Connection Table

This table describes the connection between each enclosure management module on the managed system and its enclosure.

Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table.

The following object sets up the Enclosure Management Module Connection Table.

Table 1792. Enclosure Management Module Connection Table

Name enclosureManagementModuleConnectionTable

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.14

Defines the enclosure memory module connection table.

SEQUENCE OF EnclosureManagementModuleConnectionEntry

Not accessible

Table 1793. Enclosure Management Module Connection Entry

Name

Object ID

Description

Syntax

Access Not

Index enclosureManagementModuleConnectionEntry

1.3.6.1.4.1.674.10893.1.20.130.14.1

Defines the enclosure memory module connection table entry.

EnclosureManagementModuleConnectionEntry accessible enclosureManagementModuleConnectionNumber

Table 1794. Enclosure Management Module Connection Number

Name

Object ID

Description

Syntax

Access enclosureManagementModuleConnectionNumber

1.3.6.1.4.1.674.10893.1.20.130.14.1.1

Identifies the instance number of the enclosure memory module connection entry.

Integer

Read-only

Table 1795. Enclosure Management Module Connection EMM Name

Name

Object ID

Description

Syntax

Access enclosureManagementModuleConnectionEMMName

1.3.6.1.4.1.674.10893.1.20.130.14.1.2

Identifies the name of the enclosure memory module in this connection as represented in Storage Management.

DisplayString

Read-only

Table 1796. Enclosure Management Module Connection EMM Number

Name

Object ID

Description

Syntax

Access enclosureManagementModuleConnectionEMMNumber

1.3.6.1.4.1.674.10893.1.20.130.14.1.3

Identifies the instance number in the enclosureManagementModuleTable of the enclosure memory module in this connection.

Integer

Read-only

396 Storage Management Group

Table 1797. Enclosure Management Module Connection Enclosure Name

Name

Object ID

Description

Syntax

Access enclosureManagementModuleConnectionEnclosureName

1.3.6.1.4.1.674.10893.1.20.130.14.1.4

Identifies the name of the enclosure as represented in Storage Management to which this enclosure memory module belongs.

DisplayString

Read-only

Table 1798. Enclosure Management Module Connection Enclosure Number

Name

Object ID

Description

Syntax

Access enclosureManagementModuleConnectionEnclosure Number

1.3.6.1.4.1.674.10893.1.20.130.14.1.5

Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs.

Integer

Read-only

Battery Table

This table describes available properties for each controller battery on the managed system.

The following object sets up the Battery Table.

Table 1799. Battery Table

Name

Object ID

Description

Syntax

Access batteryTable

1.3.6.1.4.1.674.10893.1.20.130.15

Defines the battery table.

SEQUENCE OF BatteryEntry

Not accessible

Table 1800. Battery Entry

Name

Object ID

Description

Syntax

Access

Index

Table 1801. Battery Number

Name

Object ID

Description

Syntax

Access batteryEntry

1.3.6.1.4.1.674.10893.1.20.130.15.1

Defines the battery table entry.

BatteryEntry

Not accessible batteryNumber batteryNumber

1.3.6.1.4.1.674.10893.1.20.130.15.1.1

Identifies the instance number of the battery entry.

Integer

Read-only

Storage Management Group 397

Table 1802. Battery Name

Name

Object ID

Description

Syntax

Access

Table 1803. Battery Vendor

Name

Object ID

Description

Syntax

Access batteryName

1.3.6.1.4.1.674.10893.1.20.130.15.1.2

Identifies the battery's name as represented in Storage Management.

DisplayString

Read-only batteryVendor

1.3.6.1.4.1.674.10893.1.20.130.15.1.3

Identifies the battery's (re)seller's name.

DisplayString

Read-only

Table 1804. Battery State

Name

Object ID

Description batteryState

1.3.6.1.4.1.674.10893.1.20.130.15.1.4

Identifies the current state of battery.

Possible values:

0: Unknown

1: OK

2: Failed

6: Degraded

7: Reconditioning

9: High

10: Low

12: Charging

21: Missing

36: Learning

Integer

Read-only

Syntax

Access

Table 1805. Battery Roll-Up Status

Name

Object ID

Description batteryRollUpStatus

1.3.6.1.4.1.674.10893.1.20.130.15.1.5

Severity of the battery state. This is the combined status of the battery and its components.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

398 Storage Management Group

Table 1805. Battery Roll-Up Status (continued)

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1806. Battery Component Status

Name

Object ID

Description batteryComponentStatus

1.3.6.1.4.1.674.10893.1.20.130.15.1.6

The status of the battery itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1807. Battery Charge Count

Name

Object ID

Description

Syntax

Access batteryChargeCount

1.3.6.1.4.1.674.10893.1.20.130.15.1.7

The number of charges that have been applied to the battery.

Integer

Read-only

Table 1808. Battery Max Charge Count

Name

Object ID

Description

Syntax

Access batteryMaxChargeCount

1.3.6.1.4.1.674.10893.1.20.130.15.1.8

The maximum number of charges that can be applied to the battery.

Integer

Read-only

Table 1809. Battery Nexus ID

Name

Object ID

Description

Syntax

Access batteryNexusID

1.3.6.1.4.1.674.10893.1.20.130.15.1.9

Durable unique ID for this EMM.

DisplayString

Read-only

Table 1810. Battery Predicted Capacity

Name batteryPredictedCapacity

Storage Management Group 399

Table 1810. Battery Predicted Capacity (continued)

Object ID

Description

1.3.6.1.4.1.674.10893.1.20.130.15.1.10

Displays the battery's ability to be charged.

Possible values:

1: Failed - The battery cannot be charged and needs to be replaced.

2: Ready - The battery can be charged to full capacity.

4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is complete.

Syntax

Access

Integer

Read-only

Table 1811. Battery Next Learn Time

Name

Object ID

Description

Syntax

Access batteryNextLearnTime

1.3.6.1.4.1.674.10893.1.20.130.15.1.11

Indicates the time (in hours) the next learn cycle must be executed

Integer

Read-only

Table 1812. Battery Learn State

Name

Object ID

Description batteryLearnState

1.3.6.1.4.1.674.10893.1.20.130.15.1.12

Specifies the learn state activity of the battery.

Possible values:

1: Failed

2: Active

4: Timed out

8: Requested

16: Idle

32: due

Syntax

Access

Integer

Read-only

Table 1813. Battery ID

Name

Object ID

Description

Syntax

Access batteryID

1.3.6.1.4.1.674.10893.1.20.130.15.1.13

Represents unique id for battery.

Integer

Read-only

Table 1814. Battery Maximum Learn Delay

Name

Object ID

Description batteryMaxLearnDelay

1.3.6.1.4.1.674.10893.1.20.130.15.1.14

The maximum amount of time (in hours) that the battery learn cycle can be delayed.

400 Storage Management Group

Table 1814. Battery Maximum Learn Delay (continued)

Syntax

Access

Integer

Read-only

Table 1815. Battery Learn Mode

Name

Object ID

Description batteryLearnMode

1.3.6.1.4.1.674.10893.1.20.130.15.1.15

Indicates current learn mode of the battery.

Possible values:

1: Auto

2: Warn

4: Autowarn

8: Unknown

Syntax

Access

Integer

Read-only

Battery Connection Table

This table describes the connection between each controller battery on the managed system and its controller. Each controller number in the table corresponds to that controller instance in the controller Table.

The following object sets up the Battery Connection Table.

Table 1816. Battery Connection Table

Name

Object ID

Description

Syntax

Access batteryConnectionTable

1.3.6.1.4.1.674.10893.1.20.130.16

Defines the battery connection table.

SEQUENCE OF BatteryConnectionEntry

Not accessible

Table 1817. Battery Connection Entry

Name

Object ID

Description

Syntax

Access

Index batteryConnectionEntry

1.3.6.1.4.1.674.10893.1.20.130.16.1

Defines the battery connection table entry.

BatteryConnectionEntry

BatteryConnectionEntry

BatteryConnectionNumber

Table 1818. Battery Connection Number

Name

Object ID

Description

Syntax

Access batteryConnectionNumber

1.3.6.1.4.1.674.10893.1.20.130.16.1.1

Identifies the instance number of the battery connection entry.

Integer

Read-only

Storage Management Group 401

Table 1819. Battery Connection Battery Name

Name

Object ID

Description

Syntax

Access batteryConnectionBatteryName

1.3.6.1.4.1.674.10893.1.20.130.16.1.2

Identifies the name of the battery in this connection as represented in Storage

Management.

DisplayString

Read-only

Table 1820. Battery Connection Battery Number

Name

Object ID

Description

Syntax

Access batteryConnectionBatteryNumber

1.3.6.1.4.1.674.10893.1.20.130.16.1.3

Identifies the instance number in the battery table of the battery in this connection.

Integer

Read-only

Table 1821. Battery Connection Controller Name

Name

Object ID

Description

Syntax

Access batteryConnectionControllerName

1.3.6.1.4.1.674.10893.1.20.130.16.1.4

Identifies the name of the controller as represented in Storage Management to which this battery belongs.

DisplayString

Read-only

Table 1822. Battery Connection Controller Number

Name

Object ID

Description

Syntax

Access batteryConnectionControllerNumber

1.3.6.1.4.1.674.10893.1.20.130.16.1.5

Identifies instance number of the controller in the controller table to which this battery belongs.

Integer

Read-only

Tape Drive Table

This table describes available properties for each tape drive on the managed system.

The following object sets up the Tape Drive Table.

Table 1823. Tape Drive Table

Name

Object ID

Description tapeDriveTable

1.3.6.1.4.1.674.10893.1.20.130.17

A table of listed Tape Drives The number of entries is related to number of Tape

Drives discovered in the system. The maximum number of entries is implementationdependent.

NOTE: The properties in this table may not be applicable to all entries.

Syntax SEQUENCE OF TapeDriveEntry

402 Storage Management Group

Table 1823. Tape Drive Table (continued)

Access Not accessible

Table 1824. Tape Drive Entry

Name

Object ID

Description

Syntax

Access tapeDriveEntry

1.3.6.1.4.1.674.10893.1.20.130.17.1

An entry in the Tape Library table. A row in this table cannot be created or deleted by

SNMP operations on columns of the table.

TapeDriveEntry

Not accessible

Table 1825. Tape Drive Number

Name

Object ID

Description

Syntax

Access tapeDriveNumber

1.3.6.1.4.1.674.10893.1.20.130.17.1.1

Instance number of this tape drive entry.

INTEGER

Read-only

Table 1826. Tape Drive Name

Name

Object ID

Description

Syntax

Access tapeDriveName

1.3.6.1.4.1.674.10893.1.20.130.17.1.2

The name of the tape drive as represented in Storage Management.

DisplayString

Read-only

Table 1827. Tape Drive Vendor

Name

Object ID

Description

Syntax

Access tapeDriveVendor

1.3.6.1.4.1.674.10893.1.20.130.17.1.3

The tape drive's manufacturer's name.

DisplayString

Read-only

Table 1828. Tape Drive Product ID

Name

Object ID

Description

Syntax

Access tapeDriveProductID

1.3.6.1.4.1.674.10893.1.20.130.17.1.4

The model number of the tape drive.

DisplayString

Read-only

Table 1829. Tape Drive Nexus ID

Name

Object ID

Description tapeDriveNexusID

1.3.6.1.4.1.674.10893.1.20.130.17.1.5

Durable unique ID for this tape drive

Storage Management Group 403

Table 1829. Tape Drive Nexus ID (continued)

Syntax

Access

DisplayString

Read-only

Table 1830. Tape Drive Bus Type

Name

Object ID

Description tapeDriveBusType

1.3.6.1.4.1.674.10893.1.20.130.17.1.6

The bus type of the tape drive.

Possible values: 8. SAS

Syntax

Access

INTEGER

Read-only

Table 1831. Tape Drive SAS Address

Name tapeDriveSASAddress

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.17.1.7

The specified SAS address if this is a SAS tape drive.

DisplayString

Read-only

Table 1832. Tape Drive Media Type

Name

Object ID

Description tapeDriveMediaType

1.3.6.1.4.1.674.10893.1.20.130.17.1.8

The Media type of the tape drive.

Possible Values: 4: Tape

Syntax

Access

INTEGER

Read-only

NVME adapter table

This table describes available NVME adapter cards on the managed system. The number of entries is related to number of

NVME Adapter cards discovered in the system.

The following object sets up the NVME adapter Table.

Table 1833. NVME Adapter Table

Name

Object ID

Description nvmeAdapterTable

1.3.6.1.4.1.674.10893.1.20.130.18

A table of listed NVME Adapter cards

NOTE: The properties in this table may not be applicable to all entries.

Syntax

Access

SEQUENCE OF NvmeAdapterEntry

Not accessible

Table 1834. NVME Adapter Entry

Name nvmeAdapterEntry

404 Storage Management Group

Table 1834. NVME Adapter Entry (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.18.1

An entry in the NvmeAdapter table. A row in this table cannot be created or deleted by

SNMP operations on columns of the table.

NvmeAdapterEntry

Not accessible

Table 1835. NVME Adapter Number

Name

Object ID

Description

Syntax

Access nvmeAdapterNumber

1.3.6.1.4.1.674.10893.1.20.130.18.1.1

Instance number of this NVME Adapter entry.

INTEGER

Read-only

Table 1836. NVME Adapter State

Name

Object ID

Description

Syntax

Access nvmeAdapterState

1.3.6.1.4.1.674.10893.1.20.130.18.1.2

The current state of the NVMe Adapter.

INTEGER

Read-only

Table 1837. NVME Adapter Controller Number

Name

Object ID

Description

Syntax

Access nvmeAdapterControllerNum

1.3.6.1.4.1.674.10893.1.20.130.18.1.3

The PCIeSSD subsystem Id to which the NVMe Adapter belongs to.

INTEGER

Read-only

Table 1838. NVME Adapter PCI Slot

Name

Object ID

Description

Syntax

Access nvmeAdapterPCISlot

1.3.6.1.4.1.674.10893.1.20.130.18.1.4

The PCI slot of the system where the adapter card is connected.

INTEGER

Read-only

Table 1839. NVME Adapter Device Name

Name

Object ID

Description

Syntax

Access nvmeAdapterDeviceName

1.3.6.1.4.1.674.10893.1.20.130.18.1.5

The device name of the NVMe Adapter as it is represented in OMSA and also the operating system.

DisplayString

Read-only

Storage Management Group 405

Table 1840. NVME Adapter Vendor

Name

Object ID

Description

Syntax

Access nvmeAdapterVendor

1.3.6.1.4.1.674.10893.1.20.130.18.1.6

NVMe Adapter manufacturer.

DisplayString

Read-only

Table 1841. NVME Adapter Product ID

Name

Object ID

Description

Syntax

Access nvmeAdapterProductID

1.3.6.1.4.1.674.10893.1.20.130.18.1.7

The product id or part number of the NVMe Adapter.

DisplayString

Read-only

Table 1842. NVME Adapter Serial Number

Name

Object ID

Description

Syntax

Access nvmeAdapterSerialNumber

1.3.6.1.4.1.674.10893.1.20.130.18.1.8

Product serial number of the NVMe Adapter.

DisplayString

Read-only

Table 1843. NVME Adapter Revision

Name

Object ID

Description

Syntax

Access nvmeAdapterRevision

1.3.6.1.4.1.674.10893.1.20.130.18.1.9

The NVMe Adapter revision.

DisplayString

Read-only

Table 1844. NVME Adapter Driver Version

Name

Object ID

Description

Syntax

Access nvmeAdapterDriverVersion

1.3.6.1.4.1.674.10893.1.20.130.18.1.10

NVMe Adapter driver version.

DisplayString

Read-only

Table 1845. NVME Adapter PCI Bus Number

Name

Object ID

Description

Syntax

Access nvmeAdapterPCIBusNo

1.3.6.1.4.1.674.10893.1.20.130.18.1.11

The PCI Bus number of the NVMe adapter.

INTEGER

Read-only

406 Storage Management Group

Table 1846. NVME Adapter PCI Device Number

Name

Object ID

Description

Syntax

Access nvmeAdapterPCIDeviceNum

1.3.6.1.4.1.674.10893.1.20.130.18.1.12

The PCI device number of the NVMe Adapter.

INTEGER

Read-only

Table 1847. NVME Adapter PCI Func Number

Name

Object ID

Description

Syntax

Access nvmeAdapterPCIFuncNum

1.3.6.1.4.1.674.10893.1.20.130.18.1.13

The PCI device number of the NVMe Adapter.

INTEGER

Read-only

Table 1848. NVME Adapter Nexus ID

Name

Object ID

Description

Syntax

Access nvmeAdapterNexusID

1.3.6.1.4.1.674.10893.1.20.130.18.1.14

Nexus ID of the NVMe Adapter.

DisplayString

Read-only

Table 1849. NVME Adapter Bus Protocol Type

Name

Object ID

Description nvmeAdapterBusProtocolType

1.3.6.1.4.1.674.10893.1.20.130.18.1.15

The Bus protocol for NVMe device: value: 9 (PCIeSSD)

Syntax

Access

INTEGER

Read-only

Table 1850. NVME Adapter Media Type

Name

Object ID

Description nvmeAdapterMediaType

1.3.6.1.4.1.674.10893.1.20.130.18.1.16

NVMe Adapter media type.

Possible Values:

1: unknown

2: ssd

Syntax

Access

INTEGER

Read-only

Table 1851. NVME Adapter Length In Mega Bytes

Name

Object ID nvmeAdapterLengthInMegaBytes

1.3.6.1.4.1.674.10893.1.20.130.18.1.17

Storage Management Group 407

Table 1851. NVME Adapter Length In Mega Bytes (continued)

Description

Syntax

Access

Size in megabytes of the NVMe Adapter.

INTEGER

Read-only

Table 1852. NVME Adapter Length Offset Bytes

Name

Object ID

Description

Syntax

Access nvmeAdapterLengthOffsetBytes

1.3.6.1.4.1.674.10893.1.20.130.18.1.18

Number of bytes after total number of megabytes have been subtracted from the total size of the NVMe Adapter.

INTEGER

Read-only

Table 1853. NVME Adapter Device ID

Name nvmeAdapterDeviceID

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.18.1.19

The device Id of the NVMe Adapter.

INTEGER

Read-only

Table 1854. NVME Adapter Model Number

Name

Object ID

Description

Syntax

Access nvmeAdapterModelNumber

1.3.6.1.4.1.674.10893.1.20.130.18.1.20

Model number of the NVMe Adapter as per the manufacturer.

DisplayString

Read-only

Table 1855. NVME Adapter Negotiated Speed

Name

Object ID

Description

Syntax

Access nvmeAdapterNegotiatedSpeed

1.3.6.1.4.1.674.10893.1.20.130.18.1.21

The negotiated speed of the NVMe adapter in GT/s.

DisplayString

Read-only

Table 1856. NVME Adapter Capable Speed

Name

Object ID

Description

Syntax

Access nvmeAdapterCapableSpeed

1.3.6.1.4.1.674.10893.1.20.130.18.1.22

The maximum rated speed of the NVMe adapter in GT/s.

INTEGER

Read-only

Table 1857. NVME Adapter Remaining Rated Write Endurance

Name nvmeAdapterRemainingRatedWrEnd

408 Storage Management Group

Table 1857. NVME Adapter Remaining Rated Write Endurance (continued)

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.130.18.1.23

The remaining percentage of writes on the NVME device.

INTEGER

Read-only

Table 1858. NVME Adapter Form Factor

Name

Object ID

Description nvmeAdapterFormFactor

1.3.6.1.4.1.674.10893.1.20.130.18.1.24

The form factor of the NVMe Adapter.

Possible Values

2 : Card

Syntax

Access

INTEGER

Read-only

Table 1859. NVME Adapter Supported Specification

Name

Object ID

Description

Syntax

Access nvmeAdapterSupportedSpec

1.3.6.1.4.1.674.10893.1.20.130.18.1.25

The NVMe specification supported by the device.

DisplayString

Read-only

Table 1860. NVME Adapter Maximum Link Width

Name

Object ID

Description

Syntax

Access nvmeAdapterMaxLinkWidth

1.3.6.1.4.1.674.10893.1.20.130.18.1.26

The maximum bus width of NVME Adapter.

INTEGER

Read-only

Table 1861. NVME Adapter Negotiated Link Width

Name

Object ID

Description

Syntax

Access nvmeAdapterNegotiatedLinkWidth

1.3.6.1.4.1.674.10893.1.20.130.18.1.27

The negotiated bus width of NVMe Adapter.

INTEGER

Read-only

Table 1862. NVME Adapter Sub Vendor

Name

Object ID

Description

Syntax

Access nvmeAdapterSubVendor

1.3.6.1.4.1.674.10893.1.20.130.18.1.28

Sub vendor of the NVMe Adapter device.

DisplayString

Read-only

Storage Management Group 409

Table 1863. NVME Adapter Available Spare

Name

Object ID

Description

Syntax

Access nvmeAdapterAvailableSpare

1.3.6.1.4.1.674.10893.1.20.130.18.1.29

The remaining available spare space on the NVME device.

INTEGER

Read-only

Logical Devices Group

The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the

Dell Storage Management Software and their relationships to each other.This group and all of its associated tables and objects are not supported on Microsoft Windows Advanced Server Limited Edition 64-bit operating system (Windows.Net-64) on a Dell

PowerEdge 7150. The following MIB tables define objects and relationships, or connections among the objects, in the Logical

Devices Group:

● Virtual Disk Table — describes available properties for each virtual disk on the managed system.

● Virtual Disk Partition -- describes the available properties for each disk partitions on the managed system.

● Array Disk Logical Connection Table — describes the connections between array disks, the virtual disk to which they belong, and their associated logical disk. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found.

Virtual Disk Table

This table describes available properties for each virtual disk on the managed system.

The following object sets up the Virtual Disk Table.

Table 1864. Virtual Disk Table

Name

Object ID

Description

Syntax

Access virtualDiskTable

1.3.6.1.4.1.674.10893.1.20.140.1

Defines the virtual disk table.

SEQUENCE OF VirtualDiskEntry

Not accessible

Table 1865. Virtual Disk Entry

Name

Object ID

Description

Syntax

Access

Index virtualDiskEntry

1.3.6.1.4.1.674.10893.1.20.140.1.1

Defines the virtual disk table entry.

VirtualDiskEntry

Not accessible virtualDiskNumber

Table 1866. Virtual Disk Number

Name

Object ID

Description

Syntax virtualDiskNumber

1.3.6.1.4.1.674.10893.1.20.140.1.1.1

Identifies the instance number of the virtual disk entry.

INTEGER

410 Storage Management Group

Table 1866. Virtual Disk Number (continued)

Access Read-only

Table 1867. Virtual Disk Name

Name

Object ID

Description

Syntax

Access virtualDiskName

1.3.6.1.4.1.674.10893.1.20.140.1.1.2

Identifies the virtual disk's label generated by Storage Management or entered by the user.

DisplayString

Read-only

Table 1868. Virtual Device Disk Name

Name

Object ID

Description

Syntax

Access virtualDiskDeviceName

1.3.6.1.4.1.674.10893.1.20.140.1.1.3

Identifies the device name used by this virtual disk's member disks.

DisplayString

Read-only

Table 1869. Virtual Disk State

Name

Object ID

Description

Syntax

Access virtualDiskState

1.3.6.1.4.1.674.10893.1.20.140.1.1.4

Identifies the current state of this virtual disk.

Possible states:

0: Unknown

1: Ready - The disk is accessible and has no known problems.

2: Failed - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online.

3: Online

4: Offline - The disk is not accessible. The disk may be corrupted or intermittently unavailable.

6: Degraded - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online.

15: Resynching

16: Regenerating

24: Rebuilding

26: Formatting

32: Reconstructing

35: Initializing

36: Background Initialization

38: Resynching Paused

52: Permanently Degraded

54: Degraded Redundancy

INTEGER

Read-only

Storage Management Group 411

Table 1870. Virtual Disk Severity

Name

Object ID

Description

Syntax

Access virtualDiskSeverity

1.3.6.1.4.1.674.10893.1.20.140.1.1.5

This entry is obsolete for Storage Management. It was replaced with RollUpStatus and

ComponentStatus for each device.

INTEGER

Read-only

Table 1871. Virtual Disk Length in Megabytes

Name

Object ID

Description

Syntax

Access virtualDiskLengthInMB

1.3.6.1.4.1.674.10893.1.20.140.1.1.6

Identifies the size of this virtual disk in megabytes. If this size is 0, it is smaller than a megabyte.

INTEGER

Read-only

Table 1872. Virtual Disk Length in Bytes

Name

Object ID

Description

Syntax

Access virtualDiskLengthBytes

1.3.6.1.4.1.674.10893.1.20.140.1.1.7

Identifies the portion of the virtual disk in bytes that is smaller than a megabyte. This size plus the virtualDiskLengthInMB is the total size of the virtual disk.

INTEGER

Read-only

Table 1873. Virtual Disk Free Space in Megabytes

Name

Object ID

Description

Syntax

Access virtualDiskFreeSpaceInMB

1.3.6.1.4.1.674.10893.1.20.140.1.1.8

This entry is obsolete. This property is not supported by virtual disks managed under

Storage Management.

INTEGER

Read-only

Table 1874. Virtual Disk Free Space in Bytes

Name

Object ID

Description

Syntax

Access virtualDiskFreeSpaceInBytes

1.3.6.1.4.1.674.10893.1.20.140.1.1.9

This entry is obsolete. This property is not supported by virtual disks managed under

Storage Management.

INTEGER

Read-only

Table 1875. Virtual Disk Write Policy

Name

Object ID

Description virtualDiskWritePolicy

1.3.6.1.4.1.674.10893.1.20.140.1.1.10

Indicates whether the controller's write cache are used when writing to a virtual disk.

412 Storage Management Group

Table 1875. Virtual Disk Write Policy (continued)

Possible values:

1: Enabled - Adaptec Write Cache Enabled Protected

2: Disabled - Adaptec Write Cache Disabled

3: LSI Write Back

4: LSI Write Through

5: Enabled Always (Adaptec only)

6: Enabled Always (SAS only)

9: Not Applicable

Syntax

Access

INTEGER

Read-only

Table 1876. Virtual Disk Read Policy

Name

Object ID

Description virtualDiskReadPolicy

1.3.6.1.4.1.674.10893.1.20.140.1.1.11

Indicates whether the controller's read cache are used when reading from a virtual disk.

Possible values:

1: Enabled - Adaptec Read Cache Enabled

2: Disabled - Adaptec Read Cache Disabled

3: LSI Read Ahead

4: LSI Adaptive Read Ahead

5: LSI No Read Ahead

9: Not Applicable

Syntax

Access

INTEGER

Read-only

Table 1877. Virtual Disk Cache Policy

Name

Object ID

Description

Syntax

Access virtualDiskCachePolicy

1.3.6.1.4.1.674.10893.1.20.140.1.1.12

Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable

INTEGER

Read-only

Table 1878. Virtual Disk Layout

Name

Object ID

Description

Syntax

Access virtualDiskLayout

1.3.6.1.4.1.674.10893.1.20.140.1.1.13

Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3:

RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAID-50 19: Concatenated RAID 1 24:

RAID-60 25: CacheCade

INTEGER

Read-only

Storage Management Group 413

Table 1879. Virtual Disk Current Stripe Size in Megabytes

Name

Object ID

Description

Syntax

Access virtualDiskCurStripeSizeInMB

1.3.6.1.4.1.674.10893.1.20.140.1.1.14

Identifies the stripe size of this virtual disk in megabytes. If this size is 0, it is smaller than a megabyte.

INTEGER

Read-only

Table 1880. Virtual Disk Current Stripe Size in Bytes

Name

Object ID

Description

Syntax

Access virtualDiskCurStripeSizeInBytes

1.3.6.1.4.1.674.10893.1.20.140.1.1.15

Identifies the portion of the stripe size in bytes that is smaller than a megabyte. This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the virtual disk.

INTEGER

Read-only

Table 1881. Virtual Disk Channel

Name

Object ID

Description

Syntax

Access virtualDiskChannel

1.3.6.1.4.1.674.10893.1.20.140.1.1.16

This entry is obsolete. This property is not supported by virtual disks managed under

Storage Management.

INTEGER

Read-only

Table 1882. Virtual Disk Target ID

Name

Object ID

Description

Syntax

Access virtualDiskTargetID

1.3.6.1.4.1.674.10893.1.20.140.1.1.17

Unique ID for the virtual disk.

INTEGER

Read-only

Table 1883. Virtual Disk LUN ID

Name

Object ID

Description

Syntax

Access virtualDiskLunID

1.3.6.1.4.1.674.10893.1.20.140.1.1.18

This entry is obsolete. This property is not supported by virtual disks managed under

Storage Management.

INTEGER

Read-only

Table 1884. Virtual Disk Roll-Up Status

Name

Object ID

Description virtualDiskRollUpStatus

1.3.6.1.4.1.674.10893.1.20.140.1.1.19

Severity of the virtual disk state. This is the combined status of the virtual disk and its components.

414 Storage Management Group

Table 1884. Virtual Disk Roll-Up Status (continued)

Syntax

Access

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

DellStatus

Read-only

Table 1885. Virtual Disk Component Status

Name

Object ID

Description virtualDiskComponentStatus

1.3.6.1.4.1.674.10893.1.20.140.1.1.20

The status of the virtual disk itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

Syntax

Access

DellStatus

Read-only

Table 1886. Virtual Disk Nexus ID

Name

Object ID

Description

Syntax

Access virtualDiskNexusID

1.3.6.1.4.1.674.10893.1.20.140.1.1.21

Durable unique ID for this virtual disk.

DisplayString

Read-only

Table 1887. Virtual Disk Array Disk Type

Name

Object ID

Description virtualDiskArrayDiskType

1.3.6.1.4.1.674.10893.1.20.140.1.1.22

Identifies the type of array (physical) disks used to create the virtual disk.

Possible values:

1: SAS

2: SATA

3: SCSI

4: IDE

99: Unknown

Storage Management Group 415

Table 1887. Virtual Disk Array Disk Type (continued)

Syntax

Access

INTEGER

Read-only

Table 1888. Virtual Disk Bad Blocks Detected

Name

Object ID

Description virtualDiskBadBlocksDetected

1.3.6.1.4.1.674.10893.1.20.140.1.1.23

Indicates if virtual disk has bad blocks.

Value: 0 - No, 1 - Yes, 2 - Not Applicable, 99 - Unknown

Syntax

Access

INTEGER

Read-only

Table 1889. Virtual Disk Encrypted

Name virtualDiskEncrypted

Object ID

Description

1.3.6.1.4.1.674.10893.1.20.140.1.1.24

Indicates if virtual disk is encrypted.

Value: 0 - No, 1 - Yes, 99 - Unknown

Syntax

Access

INTEGER

Read-only

Table 1890. Virtual Disk is CacheCade

Name

Object ID

Description virtualDiskIsCacheCade

1.3.6.1.4.1.674.10893.1.20.140.1.1.25

Indicates if this virtual disk is configured as CacheCade.

Value: 1 - Yes, 0 - No, 99 - Undetermined

Syntax

Access

INTEGER

Read-only

Table 1891. Virtual Disk Disk Cache Policy

Name

Object ID

Description virtualDiskDiskCachePolicy

1.3.6.1.4.1.674.10893.1.20.140.1.1.26

Indicates disk cache policy of the logical device.

Value: 1 - Enabled, 2 - Disabled, 99 - Undetermined

SWRAID : 2 - Enabled, 4 - Disabled, 8 - Default, 10 - Undetermined

Syntax

Access

INTEGER

Read-only

Table 1892. Virtual Disk PI Enable

Name

Object ID

Description virtualDiskPIEnable

1.3.6.1.4.1.674.10893.1.20.140.1.1.28

Indicates if T10 PI is enabled on a virtual disk.

Possible values are:

416 Storage Management Group

Table 1892. Virtual Disk PI Enable (continued)

0 : T10 PI disabled, 1 : T10 PI enabled

Syntax

Access

INTEGER

Read-only

Virtual Disk Partition

Table 1893. Virtual Disk Partition Table

Name

Object ID

Description virtualDiskPartitionTable

1.3.6.1.4.1.674.10893.1.20.140.2

A table of managed virtual disk partitions. The number of entries is related to number of partitions discovered in the system. The maximum number of entries is implementationdependent.

NOTE: The properties in this table may not be applicable to all entries.

Syntax

Access

SEQUENCE OF VirtualDiskPartitionEntry

Not-Accessible

Table 1894. Virtual Disk Partition Entry

Name

Object ID

Description

Syntax

Access virtualDiskPartitionEntry

1.3.6.1.4.1.674.10893.1.20.140.2.1

An entry in the Virtual Disk Partition table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.

VirtualDiskPartitionEntry

Not—Accessible

Table 1895. Virtual Disk Partition Number

Name

Object ID

Description

Syntax

Access virtualDiskPartitionNumber

1.3.6.1.4.1.674.10893.1.20.140.2.1.1

Instance number of this partition entry.

INTEGER

Read-only

Table 1896. Virtual Disk Partition Device Name

Name

Object ID

Description

Syntax

Access virtualDiskPartitionDeviceName

1.3.6.1.4.1.674.10893.1.20.140.2.1.2

Device name of the partition given by the operating system.

OCTET STRING

Read-only

Table 1897. Virtual Disk Partition State

Name virtualDiskPartitionState

Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.3

Storage Management Group 417

Table 1897. Virtual Disk Partition State (continued)

Description

Syntax

Access

State of the partition. This is mapped stated of the associate virtual disk.

● Active - Mapped cache disk is working fine.

● No - Fluid cache is not enabled.

● Removing - This is a transient stage during the process of disabling the cache.

● Failed - Mapped cache disk has failed.

INTEGER

Read-only

Table 1898. Virtual Disk Partition Size

Name

Object ID

Description

Syntax

Access virtualDiskPartitionSize

1.3.6.1.4.1.674.10893.1.20.140.2.1.4

Size of the partition in GB.

INTEGER

Read-only

Table 1899. Virtual Disk Partition Nexus ID

Name

Object ID

Description

Syntax

Access virtualDiskPartitionNexusID

1.3.6.1.4.1.674.10893.1.20.140.2.1.6

Durable unique ID for this partition. This comprises the controllerID, virtualDisk ID and hash mapped WWN number of this partition.

DisplayString

Read-only

Array Disk Logical Connection Table

This table describes the connections between array disks, the virtual disk to which they belong, and their associated logical disk.

For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all the object properties can be found.

The following object sets up the Array Disk Logical Connection Table.

Table 1900. Array Disk Logical Connection Table

Name

Object ID

Description

Syntax

Access arrayDiskLogicalConnectionTable

1.3.6.1.4.1.674.10893.1.20.140.3

Defines the array disk logical connection table.

SEQUENCE OF arrayDiskLogicalConnectionEntry

Not accessible

Table 1901. Array Disk Logical Connection Entry

Name

Object ID

Description

Syntax

Access arrayDiskLogicalConnectionEntry

1.3.6.1.4.1.674.10893.1.20.140.3.1

Defines the array disk logical connection table entry.

ArrayDiskLogicalConnectionEntry

Not accessible

418 Storage Management Group

Table 1901. Array Disk Logical Connection Entry (continued)

Index arrayDiskLogicalConnectionNumber

Table 1902. Array Disk Logical Connection Number

Name

Object ID

Description

Syntax

Access arrayDiskLogicalConnectionNumber

1.3.6.1.4.1.674.10893.1.20.140.3.1.1

Identifies the instance number of the disk entry.

Integer

Read-only

Table 1903. Array Disk Logical Connection Array Disk Name

Name

Object ID

Description

Syntax

Access arrayDiskLogicalConnectionArrayDiskName

1.3.6.1.4.1.674.10893.1.20.140.3.1.2

Identifies the name of the array disk in this logical connection.

DisplayString

Read-only

Table 1904. Array Disk Logical Connection Array Disk Number

Name arrayDiskLogicalConnectionArrayDiskNumber

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.140.3.1.3

Identifies the instance number of the array disk in this logical connection.

Integer

Read-only

Table 1905. Array Disk Logical Connection Virtual Disk Name

Name

Object ID

Description

Syntax

Access arrayDiskLogicalConnectionVirtualDiskName

1.3.6.1.4.1.674.10893.1.20.140.3.1.4

Identifies the name of the virtual disk to which this array disk belongs.

DisplayString

Read-only

Table 1906. Array Disk Logical Connection Virtual Disk Number

Name

Object ID

Description

Syntax

Access arrayDiskLogicalConnectionVirtualDiskNumber

1.3.6.1.4.1.674.10893.1.20.140.3.1.5

Identifies the instance number of the virtual disk to which this array disk belongs.

Integer

Read-only

Table 1907. Array Disk Logical Connection Disk Name

Name

Object ID

Description arrayDiskLogicalConnectionDiskName

1.3.6.1.4.1.674.10893.1.20.140.3.1.6

Identifies the name of the disk group to which this array disk belongs. This property is currently not supported.

Storage Management Group 419

Table 1907. Array Disk Logical Connection Disk Name (continued)

Syntax

Access

DisplayString

Read-only

Table 1908. Array Disk Logical Connection Disk Number

Name

Object ID

Description

Syntax

Access arrayDiskLogicalConnectionDiskNumber

1.3.6.1.4.1.674.10893.1.20.140.3.1.7

Identifies the instance number of the disk group to which this array disk belongs. This property is currently not supported.

Integer

Read-only

Storage Management Event Group

The Storage Management Event Group defines the properties that are sent with SNMP traps.

Table 1909. Message ID Event

Name

Object ID

Description

Syntax

Access messageIDEvent

1.3.6.1.4.1.674.10893.1.20.200.1

Storage Management event message number.

Integer

Read-only

Table 1910. Description Event

Name

Object ID

Description

Syntax

Access descriptionEvent

1.3.6.1.4.1.674.10893.1.20.200.2

Storage Management event message text describing the alert.

DisplayString

Read-only

Table 1911. Location Event

Name

Object ID

Description

Syntax

Access locationEvent

1.3.6.1.4.1.674.10893.1.20.200.3

Additional information identifying the location of the object causing the alert.

DisplayString

Read-only

Table 1912. Object Name Event

Name

Object ID

Description

Syntax

Access objectNameEvent

1.3.6.1.4.1.674.10893.1.20.200.4

Name of the object as represented in Storage Management causing the alert.

DisplayString

Read-only

420 Storage Management Group

Table 1913. Object OID Event

Name

Object ID

Description

Syntax

Access objectOIDEvent

1.3.6.1.4.1.674.10893.1.20.200.5

MIB OID of the object causing the alert.

DisplayString

Read-only

Table 1914. Object Nexus Event

Name

Object ID

Description

Syntax

Access objectNexusEvent

1.3.6.1.4.1.674.10893.1.20.200.6

Durable, unique ID of the object causing the alert.

DisplayString

Read-only

Table 1915. Current Status Event

Name

Object ID

Description

Syntax

Access currentStatusEvent

1.3.6.1.4.1.674.10893.1.20.200.7

Status of object causing the alert, if applicable.

DellStatus

Read-only

Table 1916. Previous Status Event

Name

Object ID

Description

Syntax

Access previousStatusEvent

1.3.6.1.4.1.674.10893.1.20.200.8

Previous status of object causing the alert if applicable.

DellStatus

Read-only

Table 1917. Enhanced Message ID Event

Name

Object ID

Description

Syntax

Access enhancedMessageIDEvent

1.3.6.1.4.1.674.10893.1.20.200.9

Enhanced Storage Management Message ID.

DisplayString

Read-only

Table 1918. System FQDN Event

Name

Object ID

Description

Syntax

Access systemFQDNEvent

1.3.6.1.4.1.674.10893.1.20.200.10

System FQDN of object causing the alert if applicable.

DisplayString

Read-only

Storage Management Group 421

Table 1919. Service Tag Event

Name

Object ID

Description

Syntax

Access serviceTagEvent

1.3.6.1.4.1.674.10893.1.20.200.11

Service Tag of object causing the alert if applicable.

DisplayString

Read-only

Table 1920. Chassis Service Tag Event

Name

Object ID

Description

Syntax

Access chassisServiceTagEvent

1.3.6.1.4.1.674.10893.1.20.200.12

Chassis Service Tag of object causing the alert if applicable.

DisplayString

Read-only

422 Storage Management Group

4

SNMP Traps

SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures.

Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion. SNMP traps avoid these limitations of the polling method.

An SNMP trap is an asynchronous event indicating that something significant has occurred. This is analogous to a pager receiving an important message, except that the SNMP trap frequently contains all the information needed to diagnose a fault.

Two drawbacks to SNMP traps are that they are sent using UDP, which is not a guaranteed delivery mechanism, and that they are not acknowledged by the receiver.

An SNMP trap message contains the trap’s enterprise OID, the agent IP address, a generic trap ID, the specific trap ID, a time stamp, and zero or more variable bindings (varbinds). The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator-defined trap. A varbind consists of an OID and its value and provides additional information about the trap.

In order for a management system to receive SNMP traps from a managed system, the node must be configured to send traps to the management system. Trap destination configuration depends on the operating system. When this configuration is done, a management application on the management system can wait for traps and act on them when received.

NOTE: For information on Server Administrator Storage Management traps, see in Storage Management Alert Reference,

the Alert Descriptions and Corrective Actions

.

NOTE: For the list of storage management alerts and storage management messages, see the Dell OpenManage Server

Administrator Messages Reference Guide available on the Dell Support site at dell.com/openmanagemanuals navigate to

OpenManage Software and select the version required.

Topics:

Trap Variables

Understanding The Trap Description

Understanding Trap Severity

BMC Traps

Trap Variables

This section describes the variables both on Traditional and Enhanced varbinds that are sent to the management console to provide additional information about a trap or alert generated by some event on your system. The trap variables presented here apply to all Instrumentation and RAC traps. Trap variables are sent in the order listed and are reserved for use only in traps.

When a varbind is created for a trap variable, a zero is appended to the object ID (OID) to create the OID for the varbind.

The messages associated with each alertMessage varbind are available in the Message Reference Guide and can be found by matching the alert ID in the MIB to the event ID in the Message Reference Guide .

Table 1921. Trap Variables

Variable Name

Object ID

Description

Syntax alertSystem

1.3.6.1.4.1.674.10892.1.5000.10.1

Identifies the system generating the alert.

DisplayString

Table 1922. Table Index OID

Variable Name alertTableIndexOID

SNMP Traps 423

Table 1922. Table Index OID (continued)

Object ID

Description

1.3.6.1.4.1.674.10892.1.5000.10.2

Specifies the object identifier for the index attribute in the table that contains the object causing the alert. Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object.

Syntax

OBJECT IDENTIFIER

Table 1923. Message

Variable Name

Object ID

Description

Syntax

Table 1924. Current Status

Variable Name

Object ID

Description

Syntax alertMessage

1.3.6.1.4.1.674.10892.1.5000.10.3

Describes the alert.

DisplayString alertCurrentStatus

1.3.6.1.4.1.674.10892.1.5000.10.4

Specifies the status of the object causing the alert.

DellStatus

Table 1925. Previous Status

Variable Name

Object ID

Description

Syntax

Table 1926. Data

Variable Name

Object ID

Description

Syntax

Table 1928. System FQDN

Variable Name

Object ID

Description

Syntax alertPreviousStatus

1.3.6.1.4.1.674.10892.1.5000.10.5

Specifies the previous status of the object causing the alert.

DellStatus alertData

1.3.6.1.4.1.674.10892.1.5000.10.6

Provides Server Administrator-defined data related to the alert.

Octet String

The following variables show the Enhanced varbinds:

Table 1927. Message ID

Variable Name

Object ID

Description

Syntax alertMsgID

1.3.6.1.4.1.674.10892.4.5000.10.7

Specifies the enhanced message ID for the object generating the alert.

DisplayString alertSystemFQDN

1.3.6.1.4.1.674.10892.4.5000.10.8

Specifies fully qualified domain name of the system generating the alert.

DisplayString

424 SNMP Traps

Table 1929. Service Tag

Variable Name

Object ID

Description

Syntax alertServiceTag

1.3.6.1.4.1.674.10892.4.5000.10.9

Specifies the system service tag of the system generating the alert.

DisplayString

Table 1930. Chassis Service Tag

Variable Name

Object ID

Description

Syntax alertChassisServiceTag

1.3.6.1.4.1.674.10892.4.5000.10.10

Specifies the chassis service tag of the system generating the alert.

DisplayString

Understanding The Trap Description

The following table lists in alphabetical order each line item that may appear in the trap description.

Table 1931. Trap Description

Description Line Item

Action performed was:

<Action>

Action requested was:

<Action>

Additional details:

<Additional details for the events>

<Additional power supply status information>

Battery sensor status:

<status>

Explanation

Specifies the automatic server recovery action that was performed, for example:

Action performed was: Power cycle

Specifies the user initiated host control action that was requested, for example:

Action requested was: Reboot, shutdown OS first

Specifies possible additional details about the specified device, for example:

Additional details:

Memory device: DIMM_1A Serial number: 11111111

Memory device: DIMM_1B Serial number: 22222222

Specifies any additional power supply information pertaining to the event, for example:

Power supply input AC is off, Power supply POK (power OK) signal is not normal, Power supply is turned off

Specifies the status reported by the battery sensor, for example:

Battery sensor status: Predictive failure

Chassis intrusion state:

<Intrusion state>

Specifies the chassis intrusion state (open or closed), for example:

Chassis intrusion state: Open

Chassis location: <Name of chassis>

Specifies the name of the chassis that generated the message, for example:

Chassis location: Main System Chassis

Configuration error type:

<type of configuration error>

Current sensor value (in

Amps): <Reading>

Date and time of action:

<Date and time>

Specifies the type of configuration error that occurred, for example:

Configuration error type: Revision mismatch

Specifies the current sensor value in amps, for example:

Current sensor value: 7.853

Specifies the date and time that an automatic server recovery action was performed, for example:

SNMP Traps 425

Table 1931. Trap Description (continued)

Description Line Item Explanation

Description: <Description of event>

Date and time of action: Fri May 30 23:55:44 2003.

Specifies the description of the event that occurred, for example:

Description: Chipset Err: Critical Event sensor, front panel

NMI / diagnostic interrupt was asserted.

Device location: <Location in chassis>

Specifies the location of the device in the specified chassis, for example:

Device location: Mem Card A

Discrete current state:

<State>

Discrete temperature state: <State>

Specifies the state of the current sensor, for example:

Discrete current state: Good

Specifies the state of the temperature sensor, for example:

Discrete temperature state: Good

Discrete voltage state:

<State>

Fan sensor value:

<Reading>

Log type: <Log type>

Memory device bank location: <Bank name in chassis>

Specifies the state of the voltage sensor, for example:

Discrete voltage state: Good

Specifies the fan speed in revolutions per minute (RPMs) or On/Off, for example:

Fan sensor value (in RPM): 2600

Fan sensor value: Off

Specifies the type of hardware log, for example:

Log type: Embedded Server Management (ESM)

Specifies the name of the memory bank in the system that generated the message, for example:

Memory device bank location: Bank_1

Memory device location:

<Device name in chassis>

Number of devices required for full redundancy:

<Number>

Specifies the number of power supply or cooling devices required to achieve full redundancy, for example:

Number of devices required for full redundancy: 4

Peak value (in Watts):

<Reading>

Specifies the location of the memory module in the chassis, for example:

Memory device location: DIMM_A

Specifies the peak value in Watts, for example:

Peak value (in Watts): 125

Possible memory module event cause: <list of causes>

Power Supply type: <type of power supply>

Pre-failure state was:

<State>

Previous redundancy state was: <State>

Specifies a list of possible causes for the memory module event, for example:

Possible memory module event cause: Single bit warning error rate exceeded

Single bit error logging disabled

Specifies the type of power supply, for example:

Power Supply type: VRM

Specifies the status of the previous memory message, for example:

Pre-failure state was: Failed

Specifies the status of the previous redundancy message, for example:

Previous redundancy state was: Lost

426 SNMP Traps

Table 1931. Trap Description (continued)

Description Line Item

Previous state was:

<State>

Explanation

Specifies the previous state of the sensor, for example:

Previous state was: OK (Normal)

Processor sensor status:

<status>

Redundancy unit:

<Redundancy location in chassis>

Specifies the status of the processor sensor, for example:

Processor sensor status: Configuration error

Specifies the location of the redundant power supply or cooling unit in the chassis, for example:

Redundancy unit: Fan Enclosure

SD card device type: <Type of SD card device>

Specifies the type of SD card device, for example:

SD card device type: Hypervisor

SD card state: <State of

SD card>

Sensor location: <Location in chassis>

Specifies the location of the sensor in the specified chassis, for example:

Sensor location: CPU1

Temperature sensor value

(in degrees Celsius):

<Reading>

Voltage sensor value (in

Volts): <Reading>

Specifies the state of the SD card, for example:

SD card state: Present, Failed

Specifies the temperature in degrees Celsius, for example:

Temperature sensor value (in degrees Celsius): 30

Specifies the voltage sensor value in volts, for example:

Voltage sensor value: 1.693

Understanding Trap Severity

Traps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical components for values such as amperage, voltage, and temperature. When an event occurs on your system, the Server Administrator sends information about one of the following event types to the system management console:

● Information/Informational —An event that describes the successful operation of a unit, such as a power supply turning on or a sensor reading returning to normal.

● Warning — An event that is not necessarily significant, but may indicate a possible future problem, such as crossing a warning threshold.

● Critical/Error — A significant event that indicates actual or imminent loss of data or loss of function, such as crossing a failure threshold or a hardware failure.

BMC Traps

The BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and log events when certain parameters exceed their preset thresholds. All the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.3183.1.1.1.

Table 1932. BMC Traps

TrapID

262402

262530

131330

131458

Description

Generic Critical Fan Failure

Generic Critical Fan Failure Cleared

Under-Voltage Problem (Lower Critical going low)

Under-Voltage Problem Cleared

Severity

Critical

Information

Critical

Information

SNMP Traps 427

262528

262402

262530

264962

264961

264960

2715392

2715520

Table 1932. BMC Traps (continued)

TrapID

131841

131840

65792

65920

65794

65922

65799

65927

65801

65929

131328

131456

131330

131458

131335

131463

131337

131465

131841

Description

Generic Critical Voltage Problem

Generic Critical Voltage Problem Cleared Information

Under-Temperature Warning (Lower non-critical, going low)

Under-Temperature Warning Cleared

Warning

Information

Under-Temperature Problem (Lower

Critical - going low)

Under-Temperature Problem Cleared

Over-Temperature warning (Upper noncritical, going high)

Over-Temperature warning Cleared

Over-Temperature Problem (Upper

Critical - going high)

Over-Temperature Problem Cleared

Under-Voltage Warning (Lower Non

Critical - going low)

Under-Voltage Warning Cleared

Under-Voltage Problem (Lower Critical going low)

Under-Voltage Problem Cleared

Over-Voltage Warning (Upper Non

Critical - going high)

Over-Voltage Warning Cleared

Over-Voltage Problem (Upper Critical going high)

Over-Voltage Problem Cleared

Generic Critical Voltage Problem

Severity

Critical

Critical

Information

Minor

Information

Critical

Information

Warning

Information

Critical

Information

Warning

Information

Critical

Information

Critical

131840

356096

356224

262400

Generic Critical Voltage Problem Cleared Information

Chassis Intrusion - Physical Security

Violation

Critical

Information Chassis Intrusion (Physical Security

Violation) Event Cleared

Generic Predictive Fan Failure

(predictive failure asserted)

Generic Predictive Fan Failure Cleared

Generic Critical Fan Failure

Generic Critical Fan Failure Cleared

Minor

Information

Critical

Information

Fan redundancy has been degraded

Fan Redundancy Lost

Warning

Critical

Fan redundancy has returned to Normal Information

Battery Low (Predictive Failure) Warning

Battery Low (Predictive Failure) Cleared Information

428 SNMP Traps

552704

552832

552705

552833

552706

552834

552707

552835

789249

789248

Table 1932. BMC Traps (continued)

TrapID

2715393

2715521

487169

487297

487168

487173

487301

487175

487303

487170

487298

487176

487304

487178

487306

527106

527105

527104

1076994

1076996

Description

Battery Failure

Battery Failure Cleared

CPU Thermal Trip (Over Temperature

Shutdown)

CPU Thermal Trip (Over Temperature

Shutdown) Cleared

CPU Internal Error Critical 487296 CPU

Internal Error Cleared

CPU Configuration Error

CPU Configuration Error Cleared

CPU Presence (Processor Presence detected)

Severity

Critical

Information

Critical

Information

Information

Critical

Information

Information

CPU Not Present (Processor Not

Present)

CPU BIST (Built In Self Test) Failure

Critical

CPU BIST (Built In Self Test) Failure

Cleared

CPU Disabled (Processor Disabled)

Critical

Information

CPU Enabled (Processor Enabled)

CPU Throttle (Processor Speed

Reduced)

CPU Throttle Cleared (Normal Processor

Speed)

Power Supply Redundancy Degraded

Critical

Power Supply Redundancy Lost

Power Supply Redundancy has returned to Normal

Information

Warning

Information

Warning

Critical

Information

Power Supply Inserted

Power Supply Removed

Power Supply Failure

Power Supply Failure Cleared

Power Supply Warning

Power Supply Warning Cleared

Power Supply AC Lost

Power Supply AC Restored

Memory Redundancy has been Lost

Memory redundancy has returned to

Normal

System Event Log (SEL) Cleared

System Event Log (SEL) Full (Logging

Disabled)

Information

Warning

Critical

Information

Warning

Information

Critical

Information

Critical

Information

Information

Critical

SNMP Traps 429

Table 1932. BMC Traps (continued)

TrapID

2322176

Description

ASR (Automatic System Recovery)

Timer Expired

2322177

2322178

2322179

ASR (Automatic System Recovery)

Reset Occurred

ASR (Automatic System Recovery)

Power Down Occurred

ASR (Automatic System Recovery)

Power Cycle Occurred

Severity

Critical

Critical

Critical

Critical

430 SNMP Traps

5

Storage Management Alert Reference

Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks.

Topics:

Alert Monitoring and Logging

Viewing Alerts

Alert Severity Levels

SNMP Support for Storage Management Alerts

Viewing SNMP Traps

Alert Descriptions and Corrective Actions

Alert Monitoring and Logging

The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up. If you stop the Disk Management Service, then alert monitoring and logging stops. Alert monitoring does the following:

● Updates the status of the storage object that generated the alert.

● Propagates the storage object’s status to all the related higher objects in the storage hierarchy. For example, the status of a lower-level object are propagated up to the status displayed on the Health tab for the top-level storage object.

● Logs an alert into the Alert log and Microsoft Windows application log.

● Sends an Simple Network Management Protocol (SNMP) trap if the operating system’s SNMP service is installed and enabled.

NOTE: Storage Management does not log alerts regarding the data I/O path. These alerts are logged by the respective

RAID drivers in the system alert log.

Viewing Alerts

Storage Management generates alerts that are added to the Windows application alert log and to the Server Administrator Alert log. To view these alerts in Server Administrator:

1. Select the System object in the tree view.

2. Select the Logs tab.

3. Select the Alert subtab.

You can also view these alerts in the Windows Event Viewer. Every alert consists of the following:

● Severity — Shows the severity of alert.

● Date and Time — Date and time when Storage Management logged the alert.

● Description — A brief description of the alert. To expand or collapse the alert description, click the Description column heading.

Alert Severity Levels

Each alert message in the Storage Management alert log has a severity level which indicates the nature of the alert and is displayed in the Severity field of the alert message. The severity level indicates the nature of the alert.

Table 1933. Storage Management Alert Severity

Alert Severity Component Status

Storage Management Alert Reference 431

Table 1933. Storage Management Alert Severity (continued)

OK/Normal/Informational

Warning/Non-critical

Critical/Failure/Error

No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation.

A component requires attention. This alert indicates a potential problem, but does not necessarily mean that the system has currently lost data or is nonfunctional.

For example, a Warning/Non-critical alert may indicate that a component (such as a temperature probe in an enclosure) has crossed a warning threshold.

A component has either failed or failure is imminent. This alert indicates a serious problem such as data loss or a loss of function. For example, a Critical/Failure/Error alert may indicate that an array disk has failed.

SNMP Support for Storage Management Alerts

By default, Storage Management installs SNMP trap forwarding support. For this support to function, you should have SNMP installed on the managed system prior to installing Storage Management.

NOTE: For more information on installation requirements and SNMP, see the Server Administrator documentation.

SNMP Trap Forwarding

The Storage Management alerts are displayed in the Server Administrator alert log and are forwarded to the Windows application alert log. If you have SNMP installed on the managed system (and the SNMP service is running), the Storage

Management alerts in the Windows application alert log are forwarded as SNMP traps. In order for these traps to be viewable, however, a target system or application must be configured to receive these traps. SNMP traps that are generated by Storage

Management can be viewed in any standard SNMP-compatible enterprise management console.

The Windows SNMP service must be configured to forward the SNMP traps to the target system or application. When forwarding to an application, the application should also be configured to receive the SNMP traps. The IT Assistant application is already configured to receive the SNMP traps generated by Storage Management.

See Windows operating system documentation for information on configuring the operating system to forward SNMP traps.

This information may be located under such topics as Setting up SNMP or SNMP traps . When configuring SNMP for

Windows, be sure that the SNMP traps are forwarded to the correct server. For information on configuring an application to receive SNMP traps, see the documentation for that application.

SNMP Trap Definitions

The Storage Management information base (MIB) defines the SNMP traps that Storage Management generates. These traps correspond to the alerts documented in the Alert Descriptions and Corrective Actions section. The MIB is located in ..

\sm\mibs\dcstorag.mib, a subdirectory of the Storage Management installation directory.

NOTE: Storage Management supports trap forwarding on both 32-bit and 64-bit operating systems.

Trap Variables

The Storage Management SNMP traps use a set of variables that are included with every trap. Below mentioned variables are the Traditional Varbinds:

Table 1934. Message ID Event

Name

Object ID

Description

Syntax messageIDEvent

1.3.6.1.4.1.674.10893.1.20.200.1

Storage Management alert (event) message number.

INTEGER

432 Storage Management Alert Reference

Table 1934. Message ID Event (continued)

Access Read-only

Table 1935. Description Event

Name

Object ID

Description

Syntax

Access descriptionEvent

1.3.6.1.4.1.674.10893.1.20.200.2

Storage Management event message text describing the alert.

DisplayString

Read-only

Table 1936. Location Event

Name

Object ID

Description

Syntax

Access locationEvent

1.3.6.1.4.1.674.10893.1.20.200.3

Additional information identifying the location of the object causing the alert.

DisplayString

Read-only

Table 1937. Object Name Event

Name objectNameEvent

Object ID

Description

Syntax

Access

1.3.6.1.4.1.674.10893.1.20.200.4

Name of the object as represented in Storage Management causing the alert.

DisplayString

Read-only

Table 1938. Object OID Event

Name

Object ID

Description

Syntax

Access objectOIDEvent

1.3.6.1.4.1.674.10893.1.20.200.5

MIB OID of the object causing the alert.

DisplayString

Read-only

Table 1939. Object Nexus Event

Name

Object ID

Description

Syntax

Access objectNexusEvent

1.3.6.1.4.1.674.10893.1.20.200.6

Durable, unique ID of the object causing the alert.

DisplayString

Read-only

Table 1940. Current Status Event

Name

Object ID

Description

Syntax currentStatusEvent

1.3.6.1.4.1.674.10893.1.20.200.7

Status of object causing the alert, if applicable.

DellStatus

Storage Management Alert Reference 433

Table 1940. Current Status Event (continued)

Access Read-only

Table 1941. Previous Status Event

Name

Object ID

Description

Syntax

Access previousStatusEvent

1.3.6.1.4.1.674.10893.1.20.200.8

Previous status of object causing the alert if applicable.

DellStatus

Read-only

The following table shows the new enhanced mode varbinds which would be available in the EEMI where the user can get both

Traditional and Enhanced varbinds :

Table 1942. Enhanced Message ID Event

Name

Object ID

Description

Syntax

Access enhancedMessageIDEvent

1.3.6.1.4.1.674.10893.1.20.200.9

Enhanced Message ID of object causing the alert if applicable.

DisplayString

Read-only

Table 1943. Enhanced System FQDN Event

Name

Object ID

Description

Syntax

Access systemFQDNEvent

1.3.6.1.4.1.674.10893.1.20.200.10

Hostname of object causing the alert if applicable.

DisplayString

Read-only

Table 1944. Enhanced Service Tag Event

Name

Object ID

Description

Syntax

Access serviceTagEvent

1.3.6.1.4.1.674.10893.1.20.200.11

Service Tag of object causing the alert if applicable.

DisplayString

Read-only

Table 1945. Enhanced Chassis Service Tag Event

Name

Object ID

Description

Syntax

Access chassisServiceTagEvent

1.3.6.1.4.1.674.10893.1.20.200.12

Chassis Service Tag of object causing the alert if applicable.

DisplayString

Read-only

434 Storage Management Alert Reference

Viewing SNMP Traps

SNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compatible enterprise management console. These traps are defined in the Storage Management MIB. These traps correspond to the alerts documented in the

Alert Descriptions and Corrective Actions section. For more information on the MIB and its structure, as

well as a change history of the SNMP traps, see the

Introduction

section. For more information on configuring SNMP, see

Support for Storage Management Alerts

.

Alert Descriptions and Corrective Actions

The alerts generated by the redundant array of independent disks (RAID) or Small Computer System Interface (SCSI) controllers and supported by Storage Management are displayed in the Server Administrator Alert subtab or through Windows

Event Viewer. These alerts can also be forwarded as SNMP traps to other applications.

SNMP traps that are generated for the alerts are included in the Storage Management MIB. The SNMP traps for these alerts use all of the SNMP trap variables. For the list of storage management alerts and storage management messages, see the

Dell EMC OpenManage Server Administrator Messages Reference Guide available on the Dell Support website at dell.com/ support/manuals .

Storage Management Alert Reference 435

6

Standard Data Type Definitions

This appendix contains definitions for data types that are standard in most contexts across the information technology industry.

These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib

and dcs3fru.mib

files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.

Topics:

Common Data Types

Variables with Data Types of State Capabilities and State Capabilities Unique

Dell Status Data Types

Dell Date

Common Data Types

Common data types include several types of strings, the object range, signed and unsigned bit ranges, and the familiar Boolean

(true or false) data type.

Table 1946. Common Data Types

Variable Name:

DellString

DellSecurityString

DellCostofOwnershipString

DellObjectRange

DellUnsigned8BitRange

DellUnsigned16BitRange

DellUnsigned32BitRange

DellSigned32BitRange

DellBoolean

Definition

DisplayString (SIZE (0..64))

DisplayString (SIZE (0..255))

DisplayString (SIZE (0..64))

INTEGER (1..128)

INTEGER (1..256)

INTEGER (1..65535)

Gauge (0..4294967295)

INTEGER (-2147483647..2147483647)

INTEGER (0..1 (FALSE = 0, TRUE = 1))

Variables with Data Types of State Capabilities and

State Capabilities Unique

Variables with definitions of < variable name >StateCapabilities or < variable name >StateCapabilitiesUnique are integers representing a series of bit definitions. They are NOT enumerations and should be treated as bit fields. The value is passed as a decimal value. The decimal value should be converted to hex and the appropriate bits should be parsed from hex. Some of the more common bit combinations are defined in some variables, but not all combinations are or will be defined.

Table 1947. Dell State Capabilities

Variable Name : DellStateCapabilities

Data Type : Integer

Possible Data Values Meaning of Data Value

436 Standard Data Type Definitions

Table 1947. Dell State Capabilities (continued) if set to zero(0) unknownCapabilities(1) enableCapable(2) notReadyCapable(4) enableAndNotReadyCapable (6)

Table 1948. Dell State Settings

Variable Name : DellStateSettings

Data Type : Integer

Possible Data Values if set to zero(0) unknown(1) enabled(2) notReady(4) enableAndNotReady(6)

Table 1949. Dell Probe Capabilities

Variable Name : DellProbeCapabilities

Data Type : Integer

Possible Data Values if set to zero(0) upperNonCriticalThresholdSetCapable(1) lowerNonCriticalThresholdSetCapable(2) upperNonCriticalThresholdDefaultCapable(4) lowerNonCriticalThresholdDefaultCapable(8)

The object has no capabilities.

The object’s capabilities are unknown.

The object can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).

The object is not ready.

Enable and not ready capable.

Meaning of Data Value

The object has no settings capabilities and its state is disabled.

The object’s state is unknown.

The object’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).

The object is not ready.

The object is enabled and not ready.

Meaning of Data Value

The object has no capabilities.

The upper noncritical threshold can be set.

The lower noncritical threshold can be set.

The upper noncritical threshold can be set to default.

The lower noncritical threshold can be set to default.

Dell Status Data Types

Status data types include DellStatus, DellStatusRedundancy, and DellStatusProbe.

Table 1950. Dell Status

Variable Name : DellStatus

Data Type : Integer

Possible Data Values other(1) unknown(2) ok(3) nonCritical(4)

Meaning of Data Value

The object’s status is not one of the following:

The object’s status is unknown.

The object’s status is OK.

The object’s status is warning, noncritical.

Standard Data Type Definitions 437

Table 1950. Dell Status (continued) critical(5) nonRecoverable(6) absent(7)

Table 1951. Dell Status Redundancy

Variable Name : DellStatusRedundancy

Data Type : Integer

Possible Data Values other(1) unknown(2) full(3) degraded(4) lost(5) notRedundant(6)

Table 1952. Dell Status Probe

Variable Name : DellStatusProbe

Data Type : Integer

Possible Data Values other(1) unknown(2) ok(3) nonCriticalUpper(4)

CriticalUpper(5) nonRecoverableUpper(6) nonCriticalLower(7) criticalLower(8) nonRecoverableLower(9) failed(10)

The object’s status is critical (failure).

The object’s status is nonrecoverable (dead).

The object’s status is absent

Meaning of Data Value

The object’s status is not one of the following:

The object’s redundancy status is unknown.

The object is fully redundant.

The object’s redundancy has been degraded.

The object’s redundancy has been lost.

Redundancy does not apply or it is not redundant.

Meaning of Data Value

The object’s status is not one of the following:

The status of the object is unknown.

The status of the object is OK.

The object is at the noncritical upper limit.

The object is at the critical upper limit.

The object is at the nonrecoverable upper limit.

The object is at the noncritical lower limit.

The object is at the critical lower limit.

The object is at the nonrecoverable lower limit.

The status of the object is failed.

Dell Date

Variable Name : DellDate

Data Type : DellUnsigned64BitRange Octet String (SIZE(8))

The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent back by this subagent has the most significant byte of the information as the first byte. For example, the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4.

Full Dates

Variable Name : DellDateName

438 Standard Data Type Definitions

Data Type : DisplayString DisplayString (SIZE (25))

Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm are the minutes, and ss are the seconds. uuuuuu is the number of microseconds, and +fff or -fff is the offset from UTC in minutes. For example, Friday, October 31, 2001, at

6:05:19 PM CST would be represented as 20011031180519.000000-360.

The values are zero-padded, and if a valid value for a field is not deliverable, each character in the field is replaced with an asterisk (*) character.

Standard Data Type Definitions 439

7

SNMP Sample Output

This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management

Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB). Values are shown for each object identifier (OID) in the Instrumentation MIB Version Group, the Systems Management Software Group, the System

State Group, the Chassis Information Table, and Event Log Table. The data is from a Dell PowerEdge 2650 system.

Walk .1.3.6.1.4.1.674.10892 (Agent: 'SERVER01',

Community: 'public')

.iso.org.dod.internet.private.enterprises.dell.server3

1.3.6.1.4.1.674.10892.1.1.1.0 = 5

1.3.6.1.4.1.674.10892.1.1.2.0 = 3

1.3.6.1.4.1.674.10892.1.1.3.0 = 0

1.3.6.1.4.1.674.10892.1.100.1.0 = 'Server

Administrator'

1.3.6.1.4.1.674.10892.1.100.2.0 = '5.3.0'

1.3.6.1.4.1.674.10892.1.100.3.0 = 4522

1.3.6.1.4.1.674.10892.1.100.4.0 = 'Management software for Dell systems.'

1.3.6.1.4.1.674.10892.1.100.5.0 = 1

1.3.6.1.4.1.674.10892.1.100.6.0 = 1

1.3.6.1.4.1.674.10892.1.100.7.0 = 'No Updates'

1.3.6.1.4.1.674.10892.1.100.8.0 =

'https://1.2.3.4:1311'

1.3.6.1.4.1.674.10892.1.100.9.0 = 'en_US'

1.3.6.1.4.1.674.10892.1.100.10.0 = '2.2.0'

1.3.6.1.4.1.674.10892.1.100.11.0 = 0

1.3.6.1.4.1.674.10892.1.100.12.0 = 1

1.3.6.1.4.1.674.10892.1.100.13.0 = 'Dell Inc.'

1.3.6.1.4.1.674.10892.1.200.10.1.1.1 = 1

1.3.6.1.4.1.674.10892.1.200.10.1.2.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.3.1 = 2

1.3.6.1.4.1.674.10892.1.200.10.1.4.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.5.1 = '\02'

1.3.6.1.4.1.674.10892.1.200.10.1.6.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.7.1 = '\03'

1.3.6.1.4.1.674.10892.1.200.10.1.8.1 = '\02\02'

1.3.6.1.4.1.674.10892.1.200.10.1.9.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.10.1 = '\03\03'

1.3.6.1.4.1.674.10892.1.200.10.1.11.1 =

'\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\

02\02\02'

1.3.6.1.4.1.674.10892.1.200.10.1.12.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.13.1 =

'\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\

03\03\03'

1.3.6.1.4.1.674.10892.1.200.10.1.20.1 =

'\02\02\02\02\02'

1.3.6.1.4.1.674.10892.1.200.10.1.21.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.22.1 =

'\03\03\03\03\03'

1.3.6.1.4.1.674.10892.1.200.10.1.23.1 =

'\02\02\02\02\02\02'

1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.25.1 =

'\03\03\03\03\03\03'

1.3.6.1.4.1.674.10892.1.200.10.1.26.1 =

'\02\02\02\02'

1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.28.1 =

'\03\03\03\03'

1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02'

1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03'

440 SNMP Sample Output

1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3

1.3.6.1.4.1.674.10892.1.200.10.1.43.1 = '\03'

1.3.6.1.4.1.674.10892.1.300.10.1.1.1 = 1

1.3.6.1.4.1.674.10892.1.300.10.1.2.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.3.1 = 2

1.3.6.1.4.1.674.10892.1.300.10.1.4.1 = 3

1.3.6.1.4.1.674.10892.1.300.10.1.5.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.6.1 = 23

1.3.6.1.4.1.674.10892.1.300.10.1.7.1 = 'Main System

Chassis'

1.3.6.1.4.1.674.10892.1.300.10.1.8.1 = 'Dell Inc.'

1.3.6.1.4.1.674.10892.1.300.10.1.9.1 = 'PowerEdge

2650'

1.3.6.1.4.1.674.10892.1.300.10.1.10.1 = 'ASSETTAG'

1.3.6.1.4.1.674.10892.1.300.10.1.11.1 = '1234567'

1.3.6.1.4.1.674.10892.1.300.10.1.12.1 = 254

1.3.6.1.4.1.674.10892.1.300.10.1.13.1 = 289

1.3.6.1.4.1.674.10892.1.300.10.1.14.1 = 4

1.3.6.1.4.1.674.10892.1.300.10.1.15.1 = 'SERVER01'

1.3.6.1.4.1.674.10892.1.300.10.1.16.1 =

'20050513095213.000000-360'

1.3.6.1.4.1.674.10892.1.300.10.1.17.1 =

'20050513100052.000000-360'

1.3.6.1.4.1.674.10892.1.300.10.1.18.1 = 'Please set the value'

1.3.6.1.4.1.674.10892.1.300.10.1.19.1 = 'Please set the value'

1.3.6.1.4.1.674.10892.1.300.10.1.20.1 = 'Please set the value'

1.3.6.1.4.1.674.10892.1.300.10.1.21.1 = 3

1.3.6.1.4.1.674.10892.1.300.10.1.22.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.23.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.24.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.25.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.26.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.27.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.28.1 = 8

1.3.6.1.4.1.674.10892.1.300.10.1.29.1 = 2

1.3.6.1.4.1.674.10892.1.300.10.1.30.1 = 1

1.3.6.1.4.1.674.10892.1.300.10.1.31.1 = 15

1.3.6.1.4.1.674.10892.1.300.10.1.32.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.33.1 = 27

1.3.6.1.4.1.674.10892.1.300.10.1.34.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.35.1 = 1

1.3.6.1.4.1.674.10892.1.300.10.1.36.1 = 480

1.3.6.1.4.1.674.10892.1.300.10.1.37.1 = 1

1.3.6.1.4.1.674.10892.1.300.10.1.38.1 = 2

1.3.6.1.4.1.674.10892.1.300.10.1.39.1 = 2

1.3.6.1.4.1.674.10892.1.300.10.1.44.1 = 0

1.3.6.1.4.1.674.10892.1.300.10.1.45.1 = 0

1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1 = 1

1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 = 1

1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 = 8

1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 = 2

1.3.6.1.4.1.674.10892.1.300.40.1.5.1.1 = 'Log cleared'

1.3.6.1.4.1.674.10892.1.300.40.1.6.1.1 = 2

1.3.6.1.4.1.674.10892.1.300.40.1.7.1.1 = 3

1.3.6.1.4.1.674.10892.1.300.40.1.8.1.1 =

'20050513100047.000000-360'

SNMP Sample Output 441

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals