B100PROX-EH-SA v2
B100PROX-MF-SA v2
Standalone Biometric Reader
INSTALLER’S MANUAL
1
Contents
INTRODUCTION
MOUNTING
..............................................................
....................................................................
SPECIFICATIONS ....................................................................
APPLICATION DIAGRAM ..............................................................
RECOMMENDED SWIPING TECHNIQUE
INDICATION
...........................................
..............................................................
WIRING ..............................................................
ADDING ADMIN FINGER ..............................................................
5
5
4
4
4
4
2
3
PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing B100PROX-SA v2 with DINRTT
..............................
...........................................................
Pairing B100PROX-SA v2 with RTT
Pairing B100PROX-SA v2 with RU2
...........................................................
...........................................................
6
6
6
6
ADMINISTRATOR PROGRAMMING
ADD Finger Relay 1
...........................................................
..............................................................
ADD Finger Relay 2
ADD Finger Relay 1&2
DELETE Finger
..............................................................
..............................................................
..............................................................
..............................................................
DELETE ALL Fingers
CHANGE ADMIN Finger
..............................................................
CHANGE INSTALLER Finger
..............................................................
Administrator Programming block diagram
...........................................................
7
8
8
8
8
7
7
7
7
INSTALLER PROGRAMMING
Set Relay 1 Time
...........................................................
..............................................................
Set Relay 2 Time
..............................................................
BUZZER ON/OFF
..............................................................
BACKLIGHT ON/OFF
..............................................................
Installer Programming block diagram
.............................................................
9
9
10
9
9
9
INTRODUCTION
B100PROX-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users fingers
- same performance in the different light conditions
- good reading of fingers with stains from daily jobs
Built in strong scanning and matching algorithm provides excellent tolerance in the way finger is swiped over the sensor reducing to minimum the need to repeat finger swiping at the sensor.
The reader can store up to 100 finger templates and 2000 cards. One template is reserved for User manager (Administrator), one template is reserved for Reader configuration (Installer) and up to 98 templates are for Users.
This manual is used for both B100PROX-EH-SA (EM/HID Cards) and B100PROX-MF-SA (Mifare Cards).
2
RECOMMENDATIONS
Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can increase the security of the system if needed. One or two enrolled fingers are enough for one user. Ask the installer before he leaves the site to enroll your finger as administrator.
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger. Some of the users may have very flat fingertips, making difficult for the sensor to recognize correctly the fingerprint. In most cases, these are children and older persons. To solve this problem, do the following:
1. Try with different user’s fingers to find the “best” finger.
2. Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use chemicals and materials that can scratch the sensor.
WARNING!
Do not touch the sensor with other objects than finger. Do not pour or splash with water or other liquids. When painting or construction work is ongoing in the area around the reader, protect the reader sensor area from possible damages and paint. If reader is to be dismounted or relocated, call authorized installer for the job. Disposal of this product must be handled according to all national laws and regulations.
MOUNTING
MCD-MINI
Ø6.0
Cable
100 mm
94 mm
30 mm
Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered.
If the biometric reader is installed and used outdoor, the reader MUST be fitted with the MCD-MINI metal cover available in our accessories in order to protect the sensor from direct rainfall. The operating temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a third party sealed wall mount box (fitted with additional heater if very low temperature) to keep a constant sensor level performance. XPR™ cannot guarantee the functionality of the product if measures and advice before are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use different readers depending on users.
3
SPECIFICATIONS
Fingerprint Capacity:
Prox. cards Capacity:
Card Type:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
Programming:
Master/Admin Fingers:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
IP Factor:
Storage/Operating Temperature :
Storage/Operating Humidity:
Dimensions(mm):
98 templates
2000 cards
EM or HID compatible (125KHz) - B100PROX-EH-SA or Mifare (13,56 Mhz; Classic 1K & 4K, Ultralight, Desfire) - B100PROX-MF-SA
1 x Relay (2A/24V AC/DC)
Yes
Pulse (1 to 30 seconds) or Toggle(ON/OFF)
Finger or Card
By swiping
1 Administrator and 1 Installer Finger
Yes
Yes via RS485 converter and windows application
150 mA max.
9-14 V DC
Tricolor Status LED
IP65
-20°C to +50°C
5% to 93% RH without condensation
100 x 94 x 30
APPLICATION DIAGRAM
RS
485 (ma x. 50m)
RU2 (Op onal)
2 Relay Remote Unit
DINRTT (Op onal)
2 Relay Remote Unit and request-to-exit Bu on
OR
RTT (Op onal)
1 Relay Remote Unit and request-to-exit Bu on
Secured Area Outside
B100PROX-EH/MF-SA v2
Standalone Biometric Reader
MCD-MINI
(Op onal)
Metal Cover
4
WIRING
Red
Black
Pink
Violet
Blue
Green
Orange
Gray
Yellow
White
12V DC
GND
A
B
RS485
Tamp
PB
NC
COM
NO
Colour
Red
Black
Green
Blue
Orange
Pink
Violet
Grey
Yellow
White
Connection
12V DC
GND
Tamper
Tamper
Push Button
A (RS485)
B (RS485)
NC
COM
NO
Relay
(2A)
+
_
12VDC
POWER SUPPLY
Wiring B100PROX-SA with magnetic lock
Red
Black
Pink
Violet
Blue
Green
Orange
Gray
Yellow
White
_
+
PB
NC
COM
GND (PB)
1N4001
Diode
_
+
Electro Magnetic Lock
Wiring B100PROX-SA with electric strike
DIPSwitch settings reader back view
+12V
GND
NO
COM
NC
TAMP
TAMP
PB1
A
B
Power Supply
Relay
(2A)
Push Button
RS 485
1
ON
2
Dipswitch A
(sw. no.2)
Card Type
ON: HID
OFF: EM
1
ON
2
Dipswitch B
(sw. no.2)
Adding Master Finger
CARD Type
Dipswitch A
Adding Admin Finger
Dipswitch B
Red
Black
Pink
Violet
Blue
Green
Orange
Gray
Yellow
White
+
12VDC
_ POWER SUPPLY
_
+
GND (PB)
PB
COM
NO
-
1N4001
Diode
+
Only in B100PROX-EH-SA v2
Dipswitch A: Card Type
Electric Strike
ON
1 2
ON: HID
OFF: EM
Switch No. 2
Dipswitch B: Adding Admin Finger
ON
1 2
Switch No. 2
5
RECOMMENDED SWIPING TECHNIQUE
Follow the below instructions for correct finger swiping. Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
INDICATION
Tricolor Status LED
Green - Access Granted
Red - Access denied
Orange - Idle Mode
OK Beep - short + long beep
Error Beep - 3 short beeps
Swipe Finger - 2 short beeps
ADDING ADMIN FINGER
1.Push dip switch no.2 in position ON.
2.Reset the Power of the device.
3.Wait for One long + multiple short beeps
4.Put the dip switch in position OFF. (short beeps will stop)
5.Wait for about 15 seconds for the LED to blink in Orange.
6.Swipe the Master finger min.6 times. (Until Ok Beep)
Warning: This procedure also deletes all the users and the installer finger.
Warning: This procedure will unpair the connected relay unit (RTT, DINRTT or RU2)
1 2
ON
No.2
12/24V AC/DC
1 2
ON
No.2
x 6
6
PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay’s Manual.
Pairing B100PROX-SA v2 with DINRTT
12 VDC
+
-
DINRTT
+
-
1 2
1. Close the Jumper. DINRTT beeps continuously and the red led blinks.
2. Open the Jumper
Exit Button
(NO)
G
N
D
P
B
1
GN
D
PB1
GN
D
PB2
B
RS485
B
RS485
TA
MP
TA
MP
3. Wait for Beep + OK Beep (short + short + long beep)
Black
Red
Pink
Violet
GND
+12V
B (RS485)
A (RS485) max. 50 meters
Pairing B100PROX-SA v2 with RTT
+
12 VDC
After the OK beep, the coupling is done.
12 VDC
+
-
Red
Yellow
Black
COM
GND Black
Red Brown 12V out
Pink Pink A (RS485)
Violet Violet
B (RS485) max. 50 meters
White NO
+
-
1. Put Dipswitch No.1 to position ON. RTT beeps continuously and the red led blinks.
2. Put Dipswitch No.1 to position OFF.
ON
1 2
3. Wait for Beep + OK Beep (short + short + long beep)
RTT
After the OK beep, the coupling is done.
Pairing B100PROX-SA v2 with RU2
B100PROX-SA
NO COM
RU2
Pink
A (RS485)
B (RS485)
Violet max. 50 meters
GND
+12V
+12V
GND
+
-
+
-
12 VDC
2
1 1. Put the Jumper to closed position. RU2 beeps continuously and the red led blinks.
2. Put the Jumper to open position.
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
Warning: Changing the ADMIN finger will also unpair the remote relay unit.
7
ADMINISTRATOR PROGRAMMING
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers.
Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin finger is described in installer manual.
RIGHT LEFT
ADD Finger Relay 1
(Finger that will activate on board relay 1)
Action
Swipe Admin Finger 1 time
Wait 5 seconds
(until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep) or
Finger x 1 x 6
Backlight slow blinking fast blinking
Present card/tag 1 time x 1 fast blinking
Buzzer Sound short beep short beep short + long beep short + long beep
ADD Finger Relay 2
(Finger that will activate remote relay 2)
Action
Swipe Admin Finger 2 times
Wait 5 seconds
(until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep) or
Finger x 2 x 6
Backlight slow blinking fast blinking
Present card/tag 1 time x 1 fast blinking
Buzzer Sound short beep short beep short + long beep short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
ADD Finger Relay 1&2
(Finger that will activate relay 1&2)
Action
Swipe Admin Finger 3 times
Wait 5 seconds
(until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep) or
Finger x 3 x 6
Backlight slow blinking fast blinking
Present card/tag 1 time x 1 fast blinking
Buzzer Sound short beep short beep short + long beep short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
8
DELETE Finger
Action
Swipe Admin Finger 4 times
Wait 5 seconds
(until fast blinking)
Swipe User Finger or
Present card/tag 1 time
Finger x 4 x 1 x 1
DELETE ALL Fingers and Cards
Action
Swipe Admin Finger 4 times
Wait 5 seconds
(until fast blinking)
Finger x 4
Swipe Admin Finger 2 times x 2
CHANGE ADMIN Finger
Action
Swipe Admin Finger 5 times
Wait 5 seconds
(until fast blinking)
Swipe NEW Admin Finger min.6 times
Finger x 5 x 6
CHANGE INSTALLER Finger
Action
Swipe Admin Finger 6 times
Wait 5 seconds
(until fast blinking)
Swipe NEW Installer Finger min.6 times
Finger x 6 x 6
Backlight slow blinking fast blinking fast blinking
Backlight slow blinking slow blinking fast blinking
Backlight slow blinking slow blinking fast blinking
Backlight slow blinking slow blinking fast blinking
Buzzer Sound short beep short beep short + long beep short + long beep
Buzzer Sound short beep short beep multiple beeps
Buzzer Sound short beep short beep short + long beep
Buzzer Sound short beep short + long beep
3 short beeps
9
Administrator Programming block diagram
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu
1
swipe
ADD Finger
Relay 1
(on board)
2
swipes
ADD Finger
Relay 2
(remote)
3
swipes
ADD Finger
Relay 1&2
4
swipes
DELETE FINGER
5
swipes
Change
ADMIN
Finger
6
swipes
Enroll
INSTALLER
Finger
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
SWIPE new finger min. 6 times or present card/tag
END
SWIPE new finger min. 6 times or present card/tag
SWIPE new finger min. 6 times or present card/tag
END
Only in combination with DINRTT and RU2
END
SWIPE already enrolled finger
1 time or present card/tag
SWIPE
ADMIN finger
2 times to
DELETE ALL
END END
SWIPE new ADMIN
FINGER min. 6 times
SWIPE new
INSTALLER
FINGER min. 6 times
END END
10
INSTALLER PROGRAMMING
Set Relay 1 Time (on board)
Action
Swipe Installer Finger 1 time
Wait 5 seconds
(until fast blinking)
Swipe the INSTALLER Finger
and start counting seconds
Finger x 1 x 1
Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode x 1
Backlight slow blinking fast blinking fast blinking
Buzzer Sound short beep short beep beeps on 1 second short + long beep
Set Relay 2 Time (remote)
Action
Swipe Installer Finger 2 times
Wait 5 seconds
(until fast blinking)
Swipe the INSTALLER Finger
and start counting seconds
Finger x 2 x 1
Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode x 1
Backlight slow blinking fast blinking fast blinking
Buzzer Sound short beep short beep beeps on 1 second short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
BUZZER ON/OFF
Action
Swipe Installer Finger 3 times
Wait 5 seconds
(until fast blinking)
Swipe Installer Finger
Finger x 3 x 1
Backlight slow blinking fast blinking
Buzzer Sound short beep short beep short + long beep
BACKLIGHT ON/OFF
Action
Swipe Installer Finger 4 times
Wait 5 seconds
(until fast blinking)
Finger x 4
Swipe Installer Finger x 1
Backlight slow blinking fast blinking
Buzzer Sound short beep short beep short + long beep
11
Installer Programming block diagram
Swipe the Installer Finger 1 to 4 times depending of the desired menu
1
swipe
Set
RELAY 1
Time
(on board)
Wait
5 seconds
(until fast blinking)
2
swipes
Set
RELAY 2
Time
(remote)
Wait
5 seconds
(until fast blinking)
3
swipes
BUZZER
ON/OFF
Wait
5 seconds
(until fast blinking)
Swipe the Installer Finger and start counting seconds
Swipe the Installer Finger to stop or wait 30 seconds to put the relay in toggle
ON/OFF mode
Swipe the Installer Finger and start counting seconds
Swipe the Installer Finger to stop or wait 30 seconds to put the relay in toggle
ON/OFF mode
Swipe the Installer Finger to put the Buzzer ON/OFF
END END
Only in combination with DINRTT and RU2
END
4
swipes
BACKLIGHT
ON/OFF
Wait
5 seconds
(until fast blinking)
Swipe the Installer Finger to put the Backlight
ON/OFF
END
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with
RoHS directive EN50581:2012
12

Public link updated
The public link to your chat has been updated.
Advertisement