Cino FuzzyScan F560 Series Programming Manual
Cino FuzzyScan F560 Series is a versatile and powerful scanning device that offers a wide range of features to meet your data capture needs.
With its advanced scanning technology, the F560 Series can quickly and accurately read 1D and 2D barcodes, including popular symbologies such as UPC, EAN, Code 39, Code 128, QR Code, and PDF417. This makes it ideal for use in a variety of applications, including retail, healthcare, and inventory management.
The F560 Series also features a number of user-friendly features, such as automatic scanning, a large scanning window, and a bright aiming beam. This makes it easy to use, even for first-time users.
In addition, the F560 Series is built to last, with a durable construction and a long battery life. This makes it a reliable choice for businesses that need a high-performance scanning solution.
Advertisement
Advertisement
International Edition, Rev. D14
Rev. No. Released Date
Rev.B Beta Apr. 16, 2009
Rev.B0 May 05, 2009
Rev.B1 June 22, 2009
Rev.B2 Aug. 21, 2009
Rev.B3 Oct. 16, 2009
Rev.B4 Mar. 05, 2010
Rev. B5 Apr.12, 2010
Revision History
Description
First Release
Modify “ Symbology Reading Control ” - “Code 128/EAN-128 Setting” and “ GS1 DataBar Setting”
Add “ Appendix ” - “Symbology ID Table”.
Add “ Operation Control ” - “Presentation Scanning Mode”.(Rename to “Presentation Control” on
Rev.B4)
Add “ Operation Control ” – “Time Delay to Low Power Mode”.
Add “ Symbology Reading Control ” - “Composite Code Setting”, “PDF/Micro PDF417 Setting”,
“Codablock F Setting”, Korea Post Code Setting”.
Add “ Operation Control ” – “SmartStand Power Off Timeout”.
Add “ Condensed DataWizard ” - “PDF417/Micro PDF417”, “Codablock F”, “Korea Post Code”
Modify “ Appendix ” – “ Symbology ID Table”
Add “Host Interface Selection ” - “IBM PS/2, 25-30 series keyboard wedge interface”.
Add “ Operation Control ” - “Presentation Scanning Auto-sense”.
Add “ Appendix ” – “ Symbology ID Table” – “Code 128”
Modify “ Symbology Reading Control ” - “UPC-A & UPC-E Setting”
Rename “ Serial Interface Control ” – “Time Out Control” to “Serial Response Time-out”.
Rename “ Operation Control ” – “Presentation Scanning Mode” to “Presentation Control”
Rename “ Operation Control ” – “Auto Power Off Duration” to “Light Source On Time”.
Rename “ Operation Control ” – “ Presentation Scanning Auto-sense” to “Presentation Auto-sense”
Modify “ Operation Control ” - “Good Read Duration”
Add “ Operation Control ” - “ Presentation Sensitivity”
Add ““ Appendix ” – “Master Default” System Command
Modify “ Operation Control ” - “ Hands Free Time-out”
Revision History
Rev. No.
Rev. B6
Rev. B7
Released Date
May 27, 2010
Jun 25 , 2010
Rev. B8 Sep 29 , 2010
Rev. B9
Rev. C1
Rev. C2
Rev. C3
Rev. C4
Rev. C5
Rev. C6
Rev. C7
Rev. D1
Nov 10 , 2010
Mar 04, 2011
Mar 22, 2011
Jul 22, 2011
Nov 04, 2011
Jan 02, 2012
Mar 05, 2012
Jul 25, 2012
Dec. 18, 2012
Description
Modify “ Serial Interface Control ” – “ Baud Rate”
Modify “ Symbology Reading Control ” - “UPC-A & UPC-E Setting”
Modify “ Operation Control ” - "Time Delay to Low Power Mode"
Modify “ Symbology Reading Control ” - “UPC-A & UPC-E Setting” and “EAN Setting”
Modify “ Keyboard Interface Control ” – “Keyboard Layout (Language) Setting”
Add “ Operation Control ” - “Scan Rate Control” and “Good Read Indicator”
Modify “ Serial Interface Control ” – “ Baud Rate”
Modify “ Serial Interface Control ” – “ Baud Rate”
Modify “ Symbology Reading Control ” - “Code 39 Setting”
Modify “ Serial Interface Control ” – “Protocol, ACK/NAK Setting”
Rename “ Symbology Reading Control ” - “ UCC/EAN-128” to “GS1-128”
Rename ““ Serial Interface Control ” – “ ACK/NAK Transmission Indication” to “ACK Indication”
Modify “ Serial Interface Control ” – “ACK Indication” and “Serial response time -out”.
Rename “ Condensed DataWizard ” - “ UCC/EAN-128” to “GS1-128”
Modify “ Symbology Reading Control ” - “ Codabar/ NW-7 Setting ”
Modify “ Wand/Laser Emulation Control ” – “ Code 39/Code 128 Emulation”
Add “ Operation Control ” - "1D Barcode Forward-reading Indication”, “1D Barcode Backward-reading
Indication ”, and “1D Barcode Direction Indication Transmission”.
Add “ Host Interface Selection ” – “ USB HID Legacy”
Modify “ Symbology Reading Control ” - “Code 128 Setting”
Modify “ Wand/Laser Emulation Control ” – “ Code 39/Code 128 Emulation”
Modify “ Operation Control ” - "Operation Mode Setting”, “Presentation Control”
Add “ Operation Control ” - " LED illumination Control” and “LED Illumination Delay”
Support 2D Functions.
Rev. No.
Rev. D2
Released Date
Apr. 22. 2013
Rev. D3 Aug. 20, 2013
Rev. D4
Rev. D5
Sep. 06, 2013
Mar. 06, 2014
Rev. D6
Rev. D7
Rev. D8
Feb. 06, 2015
Aug. 17, 2015
Dec. 25, 2015
Rev. D9
Rev. D10
Rev. D11
May 31, 2016
Aug. 04, 2016
Oct. 11, 2016
Rev. D12
Rev. D13
Jan. 23, 2017
Mar. 09, 2017
Rev. D14 March. 02, 2018
Revision History
Description
Modify “ Symbology Reading Control ” - “ Data Matrix Setting
Modify “ Operation Control ” - “Batch Reading rule example”
Modify “ Symbology Reading Control ” - “Readable Bar Code Setting”
Modify “ Appendix ” - “Symbology ID Table”
Modify “ Condensed DataWizard ” - “1D Bar Code Symbology” and “2D Bar Code Symbology”
Modify “ Symbology Reading Control ” - “GS1 DataBar Setting
Add “ Appendix ” – “ USB HID Legacy Mode” Quick Set
Modify “ Symbology Reading Control ” - “MaxiCode Setting”
Add “ Host Interface Selection ” – “ USB EFT Terminal Mode”
Revise “Revision History”
Add “ Getting Started ” - A670 series scanner
Add “ Operation Control ” – “Buzzer Volume”
Add “ Symbology Reading Control ” - “Small DM Code Reading”
Modify “ Operation Control ” – “Buzzer Volume”
Modify “ Operation Control ” – “Buzzer Tone Adjust”
Modify “ Operation Control ” – “Buzzer Tone Adjust”
Remove “ Operation Control ”- “Dollar Sign” ;
Add “Keyboard Interface Control” - “Dollar Sign Control”
Add new release model “A780” and “A680”.
Modified “ Symbology Reading Control ” - “Readable Symbology Setting” – “Popular 1D”
Modified “ Getting Familiar with Your FuzzyScan ” - A780 and A680 series scanner
© Copyright Cino Group
© Copyright PC Worth Int’l Co., Ltd
Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied, reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written permission of Cino. All product information and specifications shown in this document may be changed without prior notice.
Warranty
Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino
’s control, such as, but not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA procedures to return Cino for inspection.
Regulatory
Part 15 Subpart B KN22, KN24 (KN61000-2,-3,-4,-5,-6,-8,-11)
EN55022, EN55024, EN61000-3-2, EN61000-3-3,
EN60950-1, EN61000-6-3, EN61000-6-2
Class B ITE
CNS13438 LED Eye Safety IEC62471 Exempt group
AS/NZS CISPR 22 Class B Laser Eye Safety IEC60825-1 Class 1
Getting Started
Getting Familiar with Your FuzzyScan
Connecting to Your Host
Using Accessories
Configure Your FuzzyScan
Bar Code Programming Manual
Programming Procedures
Host Interface Selection
Symbology Reading Control
Keyboard Interface Control
Serial Interface Control
Wand/Laser Emulation Control
Operation Control
Condensed DataWizard
Appendix
Symbology ID Table
Keyboard Function Code Table
ASCII Input Shortcut
Host Interface Quick Set
Operation Mode Quick Set
Option Codes
System Commands
Table of Contents
5
6
10
11
43
48
52
54
71
1
3
4
79
81
82
83
84
85
87
Getting Started
Getting Familiar with Your FuzzyScan
Thank you for choosing Cino FuzzyScan Bar Code Scanner.
All FuzzyScan scanners deliver world-class performance for a broad range of applications to unleash your productivity.
FuzzyScan family includes A series area imager, F series linear imager and L series laser imager. The Antimicrobial models are available for A770, L780 and F780 series scanners which are equipped with Disinfectant-ready
Housing and Vibrator. Moreover, the option of Vibrator is available for all other series upon request. For more details, please visit our web site or contact your supplier.
This document provides an easy reference for installation and operation purpose. The complete documentation is available at www.cino.com.tw.
A770 Series
A780 Series
A680BT Series
Power Indicator
Status Indicator
Trigger
1
Scan Window
Beeper
Cable Release Hole
F790/F780/ L780 Series
F560 Series
Getting Started
A670/F680/L680 Series
Power Indicator
Status Indicator
Trigger
Scan Window
Beeper
Cable Release Hole
2
Getting Started
Connecting to Your Host
FuzzyScan scanners support USB and RS-232 Serial interfaces. Please choose your desired interface cable, then plug it into the cable interface port of the scanner and connect it to the host. If you would like to remove the cable, please straighten one end of a paper clip, and then insert it into the cable release hole to pull out the cable.
RS232 Serial
USB HID & USB COM
3
Getting Started
Using Accessories
You can enhance productivity of your workforce by using various accessories to fulfill a wide variety of application demand.
Universal Holder
The stylish Universal Holder is designed for storing your scanner when not in use. It serves to protect the scanner from lens-scratched or falling. Moreover, its artistic-design enhances the entire value of the scanner. But please note that the holder is not applicable for A series scanners.
Hand-free SmartStand
SmartStand is specifically designed for hand-free applicatio ns to maximize user’s comfort and productivity.
You can adjust the scanner holder to desired position for optimized scanning.
Thanks to the auto-sense design, the scanner is capable of switching between presentation scanning and hand-held scanning automatically while working with
SmartStand. But please note that this feature is not available for F500 series scanners.
In presentation mode, the barcode may not be detected by the scanner in an environment with very dim ambient lighting. You can select higher sensitivity level through the setting of Presentation Sensitivity to increase scanner’s sensitivity.
4
Bar Code Programming Manual
The FuzzyScan bar code commands are specially designed
Proprietary bar code labels which allow you to set the
FuzzyScan internal programming parameters. There are
System Command , Family Code and Option Code for programming purpose.
Each programmable family and bar code command label is listed on the same page with major system commands. The detailed explanations and special programming flowchart are printed on facing or following pages. You can read the explanation and set the FuzzyScan concurrently.
A supplemental bar code command menu incorporates the bar code command labels of System Command and Option
Code. As you set the FuzzyScan, open the bar code command menu to find the option code page. You may scan the desired family code and option code to set FuzzyScan. If you want to change the programming family for multiple settings, you need only turn over the programming page to find next desired programming family.
Configure Your FuzzyScan
System Command
The System Command is the highest level bar code command which directs FuzzyScan to perform immediate operations, such as entering programming mode
( PROGRAM ), exiting programming mode ( EXIT ), listing system information ( SYSLIST ), recovering to factory preset configurations (M_DEFAULT) and so on. Please note that all system commands will take a few seconds to complete the operations. User must wait for the completion beeps before scanning another bar code.
Family Code
The Family Code is scanned to select the user desired programming family. FuzzyScan has already provided more than one hundred programming families to meet any specific requirements.
Option Code
The Option Codes is a set of bar code commands represented by “ 0 –9 ”, “ A –F ” and finishing selection ( FIN ).
For most setting, you must select at least one option code following the family code selection to set the desired parameter for the selected programming family.
5
Configure Your FuzzyScan
Programming Procedures
As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the
FuzzyScan’s internal Flash Memory ASIC or memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options. You need not re-program the FuzzyScan if you want to keep the existing configurations in the next power on.
The programming procedures of FuzzyScan are designed as simple as possible for ease of setting. Most programming families take the Single Scan Selection programming procedure. But several programming families have more complex and flexible programmable options, and you must take Multiple Scans Selection, Cycling
Scan Selection or Dual Level Selection to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference.
Please give careful attention to become familiar with each programming procedure.
If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of
Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details.
Before setting the FuzzyScan, please also refer to the
“Beeping Indications” listed in Appendix to understand the details of programming beeping indications. It will be very helpful for you to know the existing status while you are programming the FuzzyScan.
Conventions of Programming Menu
Conventions
P.C.
Descriptions
Factory Default Value
Programming Category
SS : Single scan selection
MS : Multiple scans selection
CS : Cycling scan selection
DS : Dual level scan selection
( )
[ ]
Necessary Option Code
Selectable Option Code
6
Program & End
Scan
“ PROGRAM ”
FuzzyScan will enter programming mode, and inhibit all non-programming functions.
Scan
“ END ”
FuzzyScan will exit programming mode, and store all parameters in Flash Memory ASIC or non-volatile memory, then issue the completion beeping.
Please note that the FuzzyScan will take 3-4 seconds to store parameters in internal Flash Memory ASIC or nonvolatile memory after you scan the “ END ”. Please don’t turn off the power before the completion beeping. It may destroy all configured parameters.
Configure Your FuzzyScan
System List, Group & Master Default
Scan
“ SYSLIST ”
FuzzyScan will list the product information and revision number to host via selected host interface, then issue the completion beeping.
Scan
“ M_DEFAULT ”
FuzzyScan will recover all programmable parameters into factory preset configurations, then issue the completion beeping.
7
Single scan selection
“
Scan
PROGRAM
”
Scan
One of Family Codes
Scan
One of Option Codes
Yes
Repeat
Selection
“
Scan
END ”
No
Enter programming mode.
Select one of desired programming families.
Select one option code of desired parameter.
Want to select another programming family?
Exit programming mode.
Configure Your FuzzyScan
Multiple scans selection
Scan
“ PROGRAM ”
Yes
Scan
One of Family Codes
Scan One or
Several Option Codes
Repeat
Selection
No
Scan
“ END ”
Enter program m ing m ode.
Select one of desired program m ing fam ilies.
1. Select one or several option codes to select desired parameters.
2. If it ’s necessary, scan
“FIN” to terminate option code selection.
W ant to select another program m ing fam ily?
Exit program m ing m ode.
8
Cycling scan selection
Ye s
S c a n
“P R O G R A M ”
O n e o f
S c a n
F a m ily
R e p e a t
S e le c tio n
C o d e s
S c a n
O n e o f O p tio n C o d e s
S c a n
“
F IN
”
S c a n
“ E N D ”
N o
E n te r p ro g ra m m in g m o d e .
S e le c t o n e o f d e sire d p ro g ra m m in g fa m ilie s.
C y c lin g s e le c t o n e o r s e v e ra l o p tio n c o d e s o f d e s ire d p a ra m e te rs a s
“S in g le” o r “M u ltip le” s c a n s s e le c tio n .
F in is h c y c lin g s e le c tio n .
(If n e c e ssa ry )
W a n t to se le c t a n o th e r p ro g ra m m in g fa m ily ?
E x it p ro g ra m m in g m o d e .
Configure Your FuzzyScan
Dual level selection
Ye s
“
O n e o f
S c a n
P R O G R A M
S c a n
F a m ily
R e p e a t
S e le c tio n
N o
S c a n
“ E N D ”
”
C o d e s
( 1 s t ) S c a n
S e v e ra l O p tio n C o d e s
( 2 n d ) S c a n O n e o r
S e v e ra l O p tio n C o d e s
E n te r p ro g ra m m in g m o d e .
S e le c t o n e o f d e sire d p ro g ra m m in g fa m ilie s.
S e le c t s e v e ra l o p tio n c o d e s o f d e s ire d p a ra m e te rs .
1 . S e le c t o n e o r s e v e ra l o p tio n c o d e s o f d e s ire d p a ra m e te rs .
2 . If it ’s n ecessary, scan
“F IN ” to term in ate o p tio n c o d e s e le c tio n .
W a n t to se le c t a n o th e r p ro g ra m m in g fa m ily ?
E x it p ro g ra m m in g m o d e .
9
Configure Your FuzzyScan
Host Interface Selection
PROGRAM
Family Code Selection P.C Parameter Selection
Host Interface Selection
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
IBM PS/2, 25-30 series keyboard wedge interface
Standard/TTL RS-232 peer-to-peer serial
Wand Emulation
USB Com Port Emulation
PS/2 (DOS/V) direct link (keyboard replacement)
PS/2 (DOS/V) keyboard wedge turbo mode
PS/2 (DOS/V) keyboard wedge standard mode
Laser emulation
USB HID standard mode
USB HID turbo mode
USB HID Legacy
USB EFT Terminal Mode
A series doesn’t support Wand emulation, Laser emulation, USB HID Legacy and USB EFT Terminal Mode.
USB EFT Terminal Mode is only available on Trigger Mode.
F_DEFAULT
Option Code
10
13
14
17
02
06
08
09
18
19
20
21
10
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Symbol ID : 1 character
Symbology Reading Control
User Defined Symbol ID
P.C Parameter Selection
DS Code 128 (default= B )
GS1-128 (default= C )
UPC-A (default= A )
EAN-13 (default= F )
Codabar/NW-7 (default= D )
Code 39/Code 32 (default= G )
Code 93 (default= H )
Standard/Industrial 2 of 5 (default= I )
Interleaved 2 of 5 (default= J )
Matrix 2 of 5 (default= K )
China Postal Code (default= L )
German Postal Code (default= M )
IATA (default= O )
Code 11 (default= P )
MSI/Plessey (default= R )
UK/Plessey (default= S )
Telepen (default= T )
GS1 DataBar (default= X )
UPC-E (default= E )
EAN-8 (default= N )
Trioptic Code 39 (default= W )
UCC Coupon Extended Code (default= Z )
PDF417/Micro PDF417 (default= V )
Codablock F (default= Y )
Code 16K (default= Q )
Code 49 (default= U )
Korea Post Code (default= a )
QR & Micro QR Code (default= b )
Data Matrix (default= c )
Maxi Code (default= d )
Option Code
26
28
29
30
15
16
17
18
19
20
21
22
23
24
25
04
05
06
07
08
09
00
01
02
03
10
11
12
13
14
11
F_DEFAULT
2nd Option Code
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
( 1 character)
( 1 character)
( 1 character)
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Symbol ID : 1 character
Symbology Reading Control
User Defined Symbol ID
P.C Parameter Selection
DS Aztec Code (default= e )
Chinese Sensible (default= f )
Australian Post (default= g )
British Post (default= h )
Intelligent Mail (USPS 4CB/One Code) (default= j )
Japan Post (default= k )
Netherlands KIX Post (default= l )
US Planet (default= m )
US Postnet (default= o )
Option Code
36
37
38
39
41
31
32
33
34
F_DEFAULT
2nd Option Code
( 1 character)
( 1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
12
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Symbology ID Transmission
Symbology Reading Control
Symbology ID Transmission
P.C
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable symbology ID transmission
Enable prefix CINO symbology ID transmission
Enable suffix CINO symbology ID transmission
Enable both prefix and suffix CINO symbology ID transmission
Enable prefix AIM symbology ID transmission
Enable suffix AIM symbology ID transmission
Enable both prefix and suffix AIM symbology ID transmission
F_DEFAULT
Option Code
4
5
6
2
3
0
1
13
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Readable Symbology Setting
Remember to scan “FIN” to terminate this selection. But if you select the
“Auto” , FuzzyScan will terminate this selection automatically .
Symbology Reading Control
Readable Bar Code Setting
P.C
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
SS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
Parameter Selection
Auto
Popular 1D
Code 128 *
GS1-128 *
UPC-A *
UPC-E *
EAN-13 *
EAN-8 *
Codabar/NW-7 *
Code 39 *
Trioptic Code 39
Standard/Industrial 2 of 5
Matrix 2 of 5
Interleaved 2 of 5 *
China Postal Code
Germany Postal Code
Code 93 *
Code 11
MSI/Plessey
UK/Plessey
Telepen
GS1 DataBar (RSS-14) *
IATA
PDF417 * /Micro PDF417
Codablock F
Code 16K
Code 49
Korea Post Code
QR Code */ Micro QR Code *
Data Matrix *
MaxiCode
Aztec Code *
Chinese Sensible (Han Xin) Code
14
F_DEFAULT
Option Code
09
10
11
12
38
48
58
68
13
14
15
17
A0
A1
A2
A3
A4
18
19
20
21
00
03
04
05
06
C0
01
31
02
07
47
08
Configure Your FuzzyScan
Symbology Reading Control
Readable Bar Code Setting
PROGRAM F_DEFAULT
Family Code Selection P.C Parameter Selection Option Code
Readable Symbology Setting
CS
CS
CS
CS
CS
CS
CS
Australian Post
British Post
Intelligent Mail barcode
Japanese Post
KIX Post
Planet Code
Postnet
B0
B1
B3
B4
B5
B6
B8
If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add the “ Symbology ID ” into the transmitted data is also helpful to identify the specific symbology.
Above symbologies marketed with * are enabled as default. When you select “Auto”, the scanner only reads those symbologies marked with *.
"Popular 1D" includes "Code 128", "GSA-128", "UPC-A", "UPC-E", "EAN-13", "EAN-8", "Codabar/NW-7", "Code 39", " Interleaved 2 of 5", "Code 93", "GS1 DataBar
(RSS-14)".
When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include start/stop characters.
15
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Code 39 Family Setting
Symbology Reading Control
Code 39/Code 32 Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable Code 39
Enable Code 39
Select Standard Code 39 as primary format
Select Full ASCII Code 39 as primary format
Select Code 32 (PARAF, Italian Pharmaceutical) as primary format
Disable start/stop symbol transmission
Enable start/stop symbol transmission
Disable Code 32 leading A transmission
Enable Code 32 leading A transmission
Disable MOD 43 check digit verification
Enable MOD 43 check digit verification
Disable check digit transmission
Enable check digit transmission
Disable Code 39 buffering
Enable Code 39 buffering
Disable Trioptic Code 39
Enable Trioptic Code 39
Trioptic Code 39 Setting
Code 39 Min. Length
SS
MS
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Code 39 Max. Length
SS
MS
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
16
F_DEFAULT
Option Code
9
A
B
7
8
5
6
2
3
4
0
1
C
D
E
0
1
FIN
(2 digits)
FIN
(2 digits)
Configure Your FuzzyScan
PROGRAM
Code 39 Security Level
Family Code Selection P.C
SS
SS
SS
SS
Level 0
Level 1
Level 2
Level 3
Symbology Reading Control
Code 39 Setting
Parameter Selection
F_DEFAULT
Option Code
2
3
0
1
Code 39 Security Level
The scanner offers four levels of decode security for Code39 bar codes:
Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.
Level 1: If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level 2, please select level 1.
Level 2: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” Code39 bar codes.
Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread.
17
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Codabar Setting
Codabar Check Digit Settings
Codabar Min. Length
Codabar Max. Length
Symbology Reading Control
Codabar/NW-7 Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
MS
SS
MS
Parameter Selection
Disable Codabar
Enable Codabar
Select Codabar standard format
Select Codabar ABC format
Select Codabar CLSI format
Select Codabar CX format
Disable start/stop symbol transmission
Enable ABCD/ABCD start/stop symbol transmission
Enable abcd/abcd start/stop symbol transmission
Enable ABCD/TN*E start/stop symbol transmission
Enable abcd/tn*e start/stop symbol transmission
Disable check digit verification
Enable check digit verification
Disable check digit transmission
Enable check digit transmission
Modulus 16
Modulus 10/weight 3
Modulus 11
Modulus 10/weight 2
7 check DR
Weight Modulus 11
Runes (Modulus 10/weight 2)
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
0
7
8
5
6
3
4
1
2
9
A
B
C
D
E
4
5
6
2
3
0
1
FIN
(2 digits)
FIN
(2 digits)
18
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Symbology Reading Control
UPC-A & UPC-E Setting
F_DEFAULT
UPC Family Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable UPC-A
Enable UPC-A
Disable UPC-E
Enable UPC-E
Disable UPC-E expansion
Enable UPC-E expansion
Disable UPC standardization
Enable UPC standardization
Disable UPC numeric system
Enable UPC numeric system
Disable UPC-A check digit transmission
Enable UPC-A check digit transmission
Disable UPC-E check digit transmission
Enable UPC-E check digit transmission
Disable UPC “leading 1” portion
Enable UPC “leading 1” portion
Option Code
D
E
F
9
A
B
C
6
7
4
5
8
2
3
0
1
When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric system, UPC-A check digit transmission.
UPC-A Standardization
UPC-E & EAN-8 Expansion
UPC Lead 1 Numeric System
: Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.
: Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.
: To read UPC leading with the 1 numeric system, you must enable this option.
WPC Selection
(UPC/EAN/CAN)
Basic Length
Disable
Check Digit
Disable
Numeric System
With 2-digit
Addendum
With 5-digit
Addendum
Enable
Standardization
Enable
Expansion
UPC-A
UPC-E
EAN-13
EAN-8
12
8
13
8
- 1
- 1
- 1
- 1
- 1
- 1
NC
NC
+ 2
+ 2
+ 2
+ 2
+ 5
+ 5
+ 5
+ 5
+ 1
+ 1
NC
NC
0
+ 4
0
+ 5
19
Configure Your FuzzyScan
PROGRAM
Family Code Selection
UPC Supplement Setting
UPC/EAN Security Level
Supplement Scan Voting
Symbology Reading Control
UPC-A & UPC-E Setting
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Select UPC without supplement digits
Select UPC with only 2 supplement digits
Select UPC with only 5 supplement digits
Select UPC with 2/5 supplement digits
Disable force supplement digits output
Enable force supplement digits output
UPC Family Addenda Separator Off
UPC Family Addenda Separator On
Level 0
Level 1
Level 2
Only available for UPC-A & EAN-13
None
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
Level 9
Level 10
Level 11
Level 12
Level 13
F_DEFAULT
Option Code
6
7
4
5
2
3
0
1
0
1
2
B
C
D
9
A
7
8
4
5
6
2
3
0
1
20
Configure Your FuzzyScan
UPC/EAN Security Level
The scanner offers three levels of decode security for UPC/EAN bar codes:
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may significantly impair the decoding ability of the scanner.
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may increase the misread.
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels.
21
Configure Your FuzzyScan
PROGRAM
Family Code Selection
EAN Setting
EAN Supplement Setting
Supplement Scan Voting
Symbology Reading Control
EAN Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable EAN-13
Enable EAN-13
Disable EAN-8
Enable EAN-8
Disable EAN-8 expansion
Enable EAN-8 expansion
Disable EAN-13 check digit transmission
Enable EAN-13 check digit transmission
Disable EAN-8 check digit transmission
Enable EAN-8 check digit transmission
Disable ISBN/ISSN Conversion reading check
Enable ISBN/ISSN Conversion reading check
Select EAN without supplement digits
Select EAN with only 2 supplement digits
Select EAN with only 5 supplement digits
Select EAN with 2/5 supplement digits
Disable force supplement digits output
Enable force supplement digits output
EAN Addenda Separator Off
EAN Addenda Separator On
None
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
Level 9
Level 10
Level 11
Level 12
Level 13
22
F_DEFAULT
Option Code
0
7
8
5
6
3
4
1
2
9
A
B
2
3
0
1
4
5
6
7
9
A
B
C
D
7
8
5
6
2
3
0
1
4
Configure Your FuzzyScan
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels.
23
Configure Your FuzzyScan
PROGRAM
Family Code Selection
UPC/EAN Security Level
Symbology Reading Control
EAN Setting
P.C
SS
SS
SS
Parameter Selection
Level 0
Level 1
Level 2
Only available for UPC-A & EAN-13
F_DEFAULT
Option Code
0
1
2
EAN Supplement Control
SS
SS
SS
SS
SS
SS
SS
SS
Disable all specific prefix supplement digital output
Enable all specific prefix supplement digital output
Enable 491 Supplement Digit Output
Enable 978/979 Supplement Digit Output
Enable 977 Supplement Digit Output
Enable 378/379 Supplement Digit Output
Enable 414/419 Supplement Digit Output
Enable 434/439 Supplement Digit Output
0
1
2
3
4
5
6
7
UPC/EAN Security Level
The scanner offers three levels of decode security for UPC/EAN bar codes:
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may significantly impair the decoding ability of the scanner.
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may increase the misread.
EAN Supplement Control
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement digits bar codes starting with 491 prefix. The EAN without supplement digit will not be transmitted.
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable the other except 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5 supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted.
24
Configure Your FuzzyScan
PROGRAM
Family Code Selection
UCC Coupon Extended Code
Symbology Reading Control
UCC Coupon Extended Code Setting
P.C
SS
SS
Parameter Selection
Disable UCC Coupon Extended Code
Enable UCC Coupon Extended Code
F_DEFAULT
Option Code
0
1
UCC Coupon Extended Code
When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and GS1-128
Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.
25
Configure Your FuzzyScan
PROGRAM
Family Code Selection
IATA Setting
Interleaved 2 of 5 Setting
Symbology Reading Control
IATA & Interleaved 2 of 5 Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable IATA
Enable IATA
Select 15-digit fixed length IATA checking
Select variable length IATA
Disable check digit verification
Enable check digit automatic verification
Enable S/N checking digit verification only
Enable CPN checking digit verification only
Enable CPN, Airline and S/N check digit verification
Disable check digit transmission
Enable check digit transmission
Disable start/stop symbol transmission
Enable start/stop symbol transmission
Disable Interleaved 2 of 5
Enable Interleaved 2 of 5
Select Interleaved 2 of 5 as primary format
Select German Postal Code as primary format
No check character
Validate USS check digit
Validate OPCC check digit
Disable check digit transmission
Enable check digit transmission
F_DEFAULT
Option Code
A
B
8
9
6
7
4
5
C
0
1
2
3
5
6
3
4
7
8
0
1
2
26
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Code 25 Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Symbology Reading Control
Code 25 Family Setting
Parameter Selection
Disable Standard/Industrial 2 of 5
Enable Standard/Industrial 2 of 5
Disable Matrix 2 of 5
Enable Matrix 2 of 5
Disable China Postal Code
Enable China Postal Code
Disable check digit verification
Enable check digit verification
Disable check digit transmission
Enable check digit transmission
F_DEFAULT
Option Code
6
7
4
5
8
9
0
1
2
3
Code 25 Family Min. Length
SS
MS
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
Code 25 Family Max. Length
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
For Code25 setting, we recommend you to select only one type of Code 25 or set the maximum/minimum bar code length.
To decode all types of Code 25 or to variable length of Code 25 will increase the possibility of reading error.
27
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Code 11 Setting
Code 11 Min. Length
Code 11 Max. Length
Code 93 Setting
Code 93 Min. Length
Code 93 Max. Length
Symbology Reading Control
Code 11 & Code 93 Setting
SS
SS
SS
SS
SS
MS
P.C
SS
SS
SS
SS
SS
SS
SS
SS
MS
SS
MS
SS
MS
Parameter Selection
Disable Code 11
Enable Code 11
Disable check digit verification
Select 1-check digit verification
Select 2-check digit verification
Disable check digit transmission
Enable check digit transmission
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Disable Code 93
Enable Code 93
Disable check digit transmission
Enable check digit transmission
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
0
3
4
1
2
5
6
FIN
(2 digits)
FIN
(2 digits)
2
3
0
1
FIN
(2 digits)
FIN
(2 digits)
28
Configure Your FuzzyScan
PROGRAM
Family Code Selection
MSI/Plessey Setting
MSI/Plessey Min. Length
MSI/Plessey Max. Length
Symbology Reading Control
MSI/Plessey Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
MS
SS
MS
Parameter Selection
Disable MSI/Plessy
Enable MSI/Plessy
Select MOD 10 check digit
Select MOD 10-10 check digit
Select MOD 11-10 check digit
Disable check digit transmission
Enable check digit transmission
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
0
3
4
1
2
5
6
FIN
(2 digits)
FIN
(2 digits)
29
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Code 128 Setting
Code 128 Min. Length
Code 128 Max. Length
Code 128 Security Level
Symbology Reading Control
Code 128 Setting
P.C
SS
SS
SS
SS
Parameter Selection
Disable Code 128
Enable Code 128
ISBT Concatenation Off
ISBT Concatenation On
SS
MS
SS
MS
SS
SS
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Level 0
Level 1
F_DEFAULT
Option Code
0
1
2
3
FIN
(2 digits)
FIN
(2 digits)
0
1
Code 128 Security Level
The scanner offers two levels of decode security for Code128 bar codes:
Level 0: If you are experiencing misread of poor-printed or out-of-spec. bar code in level1, please select level 0.
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec." Code128 bar codes.
30
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection
GS1-128 Setting
P.C
SS
SS
Disable GS1-128
Enable GS1-128
GS1-128 Setting
Parameter Selection
GS1-128 Min. Length
GS1-128 Max. Length
SS
MS
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
SS
MS
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
0
1
FIN
(2 digits)
FIN
(2 digits)
31
Configure Your FuzzyScan
PROGRAM
Family Code Selection
UK/Plessey Setting
UK/Plessey Min. Length
UK/Plessey Max. Length
Symbology Reading Control
UK/Plessey Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
MS
SS
MS
Parameter Selection
Disable UK/Plessey
Enable UK/Plessey
Select UK/Plessey Standard Format
Select UK/Plessey CLSI Format
Disable Convert X to A-F
Enable Convert X to A-F
Disable check digit transmission
Enable check digit transmission
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
5
6
7
2
3
0
1
4
FIN
(2 digits)
FIN
(2 digits)
32
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Telepen Setting
Telepen Min. Length
Telepen Max. Length
Symbology Reading Control
Telepen Setting
P.C
SS
SS
SS
SS
SS
SS
SS
MS
SS
MS
Parameter Selection
Disable Telepen
Enable Telepen
Select Telepen Numeric mode
Select Telepen Full ASCII mode
Disable check digit transmission
Enable check digit transmission
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
2
3
0
1
4
5
FIN
(2 digits)
FIN
(2 digits)
33
Configure Your FuzzyScan
PROGRAM
GS1 DataBar Setting
GS1 DataBar Limited
Security Level
Family Code Selection
Symbology Reading Control
GS1 DataBar Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable GS1 DataBar (RSS-14)
Enable GS1 DataBar (RSS-14)
Disable GS1 DataBar Limited
Enable GS1 DataBar Limited
Disable GS1 DataBar Expanded
Enable GS1 DataBar Expanded
Level 1
Level 2
Level 3
Only available for GS1 DataBar Limited
Only available for F460, F560 scanners.
F_DEFAULT
Option Code
2
3
0
1
4
5
0
1
2
GS1 DataBar Min. Length
GS1 DataBar Max. Length
SS
MS
Default (04)
01-Maximum
Only available for GS1 DataBar Expanded
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (74)
74-Minimum
FIN
(2 digits)
SS
MS
FIN
(2 digits)
Only available for GS1 DataBar.
Expanded Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
GS1 128 Limited Security Level
The scanner F460/F560 offers three levels of decode security for GS1 DataBar Limited bar codes:
Level 1: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 1. This is the most aggressive setting and may increase the misread.
Level 2: If you are experiencing misread of poor-printed or out-of-spec. bar code in level 3, please select level 2.
Level 3: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec." GS1 128 Limited” bar codes.
34
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Composite Codes Setting
Codablock F Setting
PDF417/Micro PDF417 Setting
P.C
SS
SS
SS
SS
SS
SS
Symbology Reading Control
Composite Codes, Codablock F
PDF417/MicroPDF417 & Setting
Parameter Selection
Disable composite codes
Enable composite codes
UPC Composite Mode: UPC never linked
UPC Composite Mode: UPC always linked
If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted whether MicroPDF417 symbol is detected or not.
If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.
F_DEFAULT
Option Code
0
1
2
3
Disable
Enable
0
1
SS
SS
SS
SS
Disable PDF417
Enable PDF417
Disable MicroPDF417
Enable MicroPDF417
2
3
0
1
35
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Code 16K Setting
Symbology Reading Control
Code 16K & Code 49 Setting
P.C
SS
SS
Disable Code 16K
Enable Code 16K
Parameter Selection
Code 16K Min. Length
Code 16K Max. Length
Code 49 Setting
SS
MS
SS
MS
SS
SS
Default (01)
01-Maximum
Scan 3 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (160)
160-Minimum
Scan 3 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Disable Code 49
Enable Code 49
Code 49 Min. Length
Code 49 Max. Length
SS
MS
SS
MS
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (81)
81-Minimum
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
0
1
FIN
(3 digits)
FIN
(3 digits)
0
1
FIN
(2 digits)
FIN
(2 digits)
36
Configure Your FuzzyScan
PROGRAM
Family Code Selection
QR Code Setting
QR Code Min. Length
QR Code Max. Length
Symbology Reading Control
QR Code Setting
P.C
SS
SS
SS
MS
SS
MS
Parameter Selection
Disable QR Code
Enable QR Code
Disable MicroQR Code
Enable MicroQR Code
Disable QR Code Append
Enable QR Code Append
Disable QR Code Inverse Reading
Enable QR Code Inverse Reading
Auto detect QR Code Inverse Reading
Default (01)
01-Maximum
Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (7089)
7089-Minimum
Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
0
3
4
1
2
5
6
7
8
FIN
(4 digits)
FIN
(4 digits)
37
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Data Matrix Setting
Symbology Reading Control
Data Matrix Setting
Data Matrix Min. Length
Small DM Code Reading
Data Matrix Max. Length
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
MS
SS
SS
SS
Parameter Selection
Disable Data Matrix
Enable Data Matrix
Disable Data Matrix Inverse Reading
Enable Data Matrix Inverse Reading
Auto Detect Data Matrix Inverse Reading
Disable Data Matrix Mirror Images
Enable Data Matrix Mirror Images
Auto Detect Data Matrix Mirror Images
Default (01)
01-Maximum
Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (3116)
3116-Minimum
Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Standard
Level 1
Level 2
F_DEFAULT
Option Code
7
8
9
4
5
0
1
6
FIN
(4 digits)
FIN
(4 digits)
0
1
2
Small DM Code Reading:
When small DataMatrix code can’t be read by 2D scanner, you can select "Level 1” or “Level 2” to improve the scanner's ability to read small DataMatrix code. The scanner’s snappiness decreased when you select “Level 1” or “Level 2”. The higher level will take longer time to read the small DataMatrix barcode.
Small DM Code Reading:
Available firmware: A780 / A680 1.00.01 and above
A770 1.00.24 and above; 2.00.08 and above
A670 1.00.05 and above
38
Configure Your FuzzyScan
PROGRAM
Family Code Selection
MaxiCode Setting
Symbology Reading Control
MaxiCode Setting
P.C
SS
SS
Disable MaxiCode
Enable MaxiCode
Parameter Selection
MaxiCode Min. Length
MaxiCode Max. Length
SS
MS
SS
MS
Default (01)
01-Maximum
Scan 3 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (150)
150-Minimum
Scan 3 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
0
1
FIN
(3 digits)
FIN
(3 digits)
39
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Aztec Code Setting
Aztec Code Min. Length
Aztec Code Max. Length
Symbology Reading Control
Aztec Code Setting
P.C
SS
SS
Disable Aztec Code
Enable Aztec Code
Parameter Selection
SS
MS
SS
MS
Default (01)
01-Maximum
Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
Default (3832)
3832-Minimum
Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
40
F_DEFAULT
Option Code
0
1
FIN
(4 digits)
FIN
(4 digits)
PROGRAM
Family Code Selection
Australian Post Setting
US Planet Setting
US Postnet Setting
British Post Setting
Japan Post Setting
SS
SS
SS
SS
SS
SS
SS
SS
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Symbology Reading Control
Australian Post, US Planet, US Postnet,
British Post & Japan Post Setting
Parameter Selection
Disable Australian Post
Enable Australian Post
Raw format Output
Numeric Encoding Output (N Encoding Table)
Alphanumeric Encoding Output (C Encoding Table)
Auto-discriminate Output (Combination C & N Encoding Table)
Disable US Planet
Enable US Planet
Disable Check Digit Transmission
Enable Check Digit Transmission
SS
SS
Disable US Postnet
Enable US Postnet
Disable Check Digit Transmission
Enable Check Digit Transmission
Disable British Post
Enable British Post
Disable Check Digit Transmission
Enable Check Digit Transmission
Disable Japan Post
Enable Japan Post
Configure Your FuzzyScan
F_DEFAULT
Option Code
3
4
5
0
1
2
0
1
2
3
0
1
2
3
0
1
2
3
0
1
Australian Post Setting: Auto-discriminate output option increase the risk of misread because the encoded data format does not specify the Encoding Table used for encoding.
41
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Netherlands KIX Code Setting
Symbology Reading Control
Netherlands KIX Code, Intelligent Mail
& Korea Post Code Setting
P.C
SS
SS
Parameter Selection
Disable Netherlands KIX Code
Enable Netherlands KIX Code
Intelligent Mail Setting
(USPS 4CB/One Code)
Korea Post Code Setting
SS
SS
Disable Intelligent Mail
Enable Intelligent Mail
SS
SS
Disable
Enable
Length fixed in 6 characters.
42
F_DEFAULT
Option Code
0
1
0
1
0
1
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Keyboard Layout
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Keyboard Interface Control
Keyboard Layout (Language) Setting
Parameter Selection
USA (QWERTY)
France (AZERTY)
Germany (QWERTZ)
United Kingdom - UK (QWERTY)
Canadian French (QWERTY)
Spain (Spanish, QWERTY)
Sweden/Finland (QWERTY)
Portugal (QWERTY)
Norway (QWERTY)
Spain (Latin America, QWERTY)
Italy (QWERTY)
Netherlands (QWERTY)
Denmark (QWERTY)
Belgium (AZERTY)
Switzerland-Germany (QWERTZ)
Iceland (QWERTY)
Japan (DOS/V)
Czech (QWERTY)
F_DEFAULT
Option Code
11
12
13
14
08
09
10
15
16
17
04
05
06
07
00
01
02
03
Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as preamble or postamble.
To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first.
Keyboard Interface Message String :
Preamble
1-15 characters
Data Length
2-4 digits
Prefix Symbol ID
1 or 3 characters
Scanned Data
Variable length
Suffix Symbol ID
1 or 3 characters
Postamble
1-15 characters
Record Suffix
1 character
43
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Record Suffix
Preamble
Postamble
FNC1 Symbol Char. Transmit
P.C
SS
SS
SS
SS
SS
SS
SS
MS
Keyboard Interface Control
Record Suffix, Preamble, Postamble,
FNC1 Transmit & Caps Lock
Parameter Selection
None
RETURN
TAB
SPACE
ENTER (Numeric Key Pad)
User defined character (1 character)
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
SS
MS
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
SS
SS
Disable
Enable
Caps Lock Control
Caps Lock Release Control
SS
SS
SS
“Caps Lock Off” State
“Caps Lock On” State
Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)
SS
SS
“Caps Lock On, Caps Off”
“Caps Lock On, Shift Off”
44
F_DEFAULT
Option Code
2
3
0
1
4
5, (00-7F)
FIN
[00-7F], [FIN]
FIN
[00-7F], [FIN]
0
1
0
1
2
0
1
Configure Your FuzzyScan
FNC1 Symbol Char. Transmit: When this function is enabled and the FNC1 is contained in scanned data, the scanner transmits the FNC1 to the host. Chart of theFNC1 is provided in Appendix- Keyboard Function Code Table. When the scanner interface is set to keyboard, the scan code is converted to corresponding key function before it is transmitted.
The function of “ Caps Lock Control ” and “ Key Pad Emulation ” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines.
While selecting the other host interfaces, these selections don’t perform the above functions for you.
Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “ Caps Lock Off ” state, and then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select “ Caps Lock On ” state. Select “ Auto Detect ”, FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch.
45
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Intermessage Delay
Keyboard Interface Control
Delay Setting
Intercharacter Delay
Interfunction Delay
P.C
SS
MS
SS
MS
SS
MS
Parameter Selection
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
FIN
(2 digits)
FIN
(2 digits)
FIN
(2 digits)
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters.
Interfunction Delay is a time delay of transmission of segments in each message string.
46
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Function Key Emulation
P.C
SS
SS
Keyboard Interface Control
Emulation Setting, Key Pad Emulation &
Upper/Lower Case Setting , Dollar Sign Control
Parameter Selection
Enable ASCII 00-31 code as keyboard function code output
Ctrl-Output
Refer to Appendix – Keyboard Function Code Table for details.
Key Pad Emulation SS
SS
Disable key pad emulation
Enable numeric output as key pad (Num Lock On) output
Upper/Lower Case
Dollar Sign Control
SS
SS
SS
SS
Normal case (neglect the upper/lower case control)
Inverse case (change all characters output to inverse case)
Upper case (force all characters output as upper case)
Lower case (force all characters output as lower case)
SS
SS
SS
SS
SS
Dollar sign output as “ $ “
Dollar sign output as “ ¥ “
Dollar sign output as “ € “
Dollar sign output as “ £ “
Dollar sign output as “ ¢ “
47
F_DEFAULT
Option Code
0
1
2
3
0
1
4
2
3
0
1
0
1
Configure Your FuzzyScan
PROGRAM
Family Code Selection
STX/ETX Control
Record Suffix
Preamble
Serial Interface Control
Record Suffix, Preamble ,Postamble Setting
SS
SS
SS
SS
SS
SS
P.C
SS
SS
Parameter Selection
Disable STX/ETX transmission
Enable STX/ETX transmission
STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
None
CR (0DH)
LF (0AH)
CRLF (0D0AH)
TAB (09H)
SPACE (20H)
MS 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
F_DEFAULT
Option Code
0
1
2
3
0
1
4
5
[00-7F], [FIN]
Postamble
SS
MS
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
FNC1 Symbol Char. Transmit
SS
SS
Disable
Enable
When this function is enabled and the FNC1 is contained in scanned data, the scanner transmits the FNC1 to the host. Chart of the FNC1 is provided in Appendix –
Keyboard Function Code Table. When the scanner interface is set to keyboard, the scan code is converted to corresponding key function before it is transmitted
Serial Interface Message String (RS232, USB COM) :
STX
1 character
Preamble
1-15 characters
Data Length
2-4 digits
Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble
1 or 3 characters Variable length 1 or 3 characters 1-15 characters
ETX
1 character
FIN
[00-7F], [FIN]
0
1
Record Suffix
1 character
48
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Intermessage Delay
Serial Interface Control
Delay Setting
P.C
SS
MS
F_DEFAULT
Option Code
FIN
(2 digits)
Intercharacter Delay
Interfunction Delay
SS
MS
SS
MS
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
FIN
(2 digits)
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters.
Interfunction Delay is a time delay between transmission and reception of each segment of the message string.
Parameter Selection
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.
49
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Handshaking Protocol
Serial Interface Control
Protocol, ACK/NAK Setting
P.C
SS
SS
SS
SS
Parameter Selection
None (free running mode)
RTS/CTS (hardware handshaking)
ACK/NAK (software handshaking)
Xon/Xoff (software handshaking)
F_DEFAULT
Option Code
2
3
0
1
NAK Retry Count
ACK Indication
SS
SS
3 times
0~255 times
SS
SS
SS
SS
Disable ACK Time-out Indication
Enable ACK Time-out Indication
Disable ACK Indication
Enable ACK Indication
FIN
(3 digits)
2
3
0
1
USB COM doesn’t support RTS/CTS handshaking protocol.
When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.’
NAK Retry Count
After transmitting data, the scanner expects a NAK response from the host up to the preset “Serial Response Time-out”. If the scanner doesn’t get a response, the scanner will issue an error indication and discard the data. When a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. The scanner issues an error indication and discards the data under following two conditions:
1) After preset NAK retry counts is received within the preset serial response time-out.
2) If the preset time-out is up but the preset NAK retry counts haven’t come to the end.
The default retry counts are three times. If you program “0 time”, the scanner won’t resend the data to the host when the scanner receives a NAK. The scanner will discard the data. If you program “255 times”, the scanner can receive unlimited NAKs from the host within the pre-set serial response time-out.
This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disable automatically.
ACK Indication:
Disable: There’s neither LED nor beeping indication for this setting.
Enable: There’s a specific LED and beeping indication for this setting.
50
Configure Your FuzzyScan
PROGRAM
Baud Rate (BPS)
Data Frame
Family Code Selection
Serial Response Time-out
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Serial Interface Control
Response Time-out Setting,
None
200 mseconds
500 mseconds
800 mseconds
1 second
2 seconds
38.4K BPS
19.2K BPS
9600 BPS
4800 BPS
8, None, 1
8, Odd, 1
8, Even, 1
8, Space, 1
8, Mark, 1
8, None, 2
7, Odd, 1
7, Even, 1
Baud Rate, Data Frame
Parameter Selection
3 seconds
4 seconds
5 seconds
8 seconds
10 seconds
15 seconds
2400 BPS
1200 BPS
57.6K BPS
115.2K BPS
7, Space, 1
7, Mark, 1
7, None, 2
7, Odd, 2
7, Even, 2
7, Space, 2
7, Mark, 2
2
3
4
0
1
5
6
7
F_DEFAULT
0
1
2
3
Option Code
2
3
0
1
4
5
8
9
6
7
A
B
4
5
8
9
A
B
C
8
9
D
E
When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data
communication. This option is very helpful to ensure the reliability of data communication.
The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer
51
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Output Polarity
Initial Signal State
Margin Time
SS
SS
SS
SS
SS
P.C
SS
SS
SS
SS
Wand/Laser Emulation Control
( F & L Series )
Output Polarity, Signal State, Margin/Module Time
Parameter Selection
High level (5Vdc) on Bar (low level on Space)
Low level (0Vdc) on Bar (high level on Space)
Determine the output voltage level for both bar and space.
High Level (5Vdc)
Low Level (0Vdc)
Determine the initial state of output voltage level.
10 msec.
15 msec.
20 msec.
25 msec.
30 msec.
Module Time
Narrow/Wide Ratio
SS
SS
SS
SS
SS
Long
1:2.5
1:3
F_DEFAULT
Option Code
0
1
0
1
2
2
3
2
3
0
1
4
0
1
52
Configure Your FuzzyScan
Wand/Laser Emulation Control
(F & L Series)
Output Polarity, Signal State, Margin/Module Time
PROGRAM F_DEFAULT
Family Code Selection P.C Parameter Selection Option Code
Code 39/Code 128 Emulation
SS
SS
SS
SS
Disable standard Code 39 emulation
Enable Full ASCII Code 39 emulation
Enable standard Code 39 skip emulation
Enable standard Code 39 replace emulation
0
1
2
3
SS Enable Code 128 emulation 4
[ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped .
[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space.
53
Configure Your FuzzyScan
Operation Control
(F & L Series)
Operation Mode Setting
PROGRAM F_DEFAULT
Family Code Selection P.C Parameter Selection Option Code
Operation Mode
SS
SS
SS
SS
SS
SS
Low Power mode
Trigger mode
Flash mode
Force mode
Presentation mode
Alternative mode
0
1
2
3
4
5
SS
SS
Toggle mode
Diagnostic mode
6
7
SS Level mode 8
Low Power Mode (Low Power Triggering): The scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation.
It is very helpful for mobile data collection and application, which are concerned with power saving.
Trigger Mode (External Triggering): The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner before scanning the bar code.
Presentation Mode (Auto Detection): Presentation mode uses ambient light to detect the bar codes. The light source is off until the scanner detects an image which is similar to a barcode. Then the light source turns on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work properly. You can choose different level of “Presentation Sensitivity” to meet your application (Please refer to the setting of “ Presentation Sensitivity ”).
Alternative Mode (Periodic Power Off) :The scanner keeps the light source of the scanner turned on till the pre-defined light source on time is up. After the scanner turns off the light source, you must press the trigger to turn on the light source again. After each good read, the timer counter of “Light Source on Time” is reset. For you do not have to press the trigger frequently, it is very convenient for multiple scanning.
Flash Mode (Pulse Driven Reading): The scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image which is similar to a bar code, the scanner forces on the light source automatically and scans the bar code. Flash Duty Cycle adjustment can change the frequency of the blinking.
Force Mode (Continued Power On): The light source of the scanner is forced on for continued operation without pressing the trigger switch. This mode is convenient for high speed bar code reading.
Toggle Mode (Repeat Reading): The toggle mode is very similar to the Alternative Mode but without the pre-defined light source on time concern. You must press the trigger to turn on the light source of the scanner to scan. The scanner keeps the light source turned on until you press the trigger again.
Diagnostic Mode (Test Reading): This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the light source of the scanner is force on without regard for other programmable parameters, such as reread delay, redundancy, and so forth.
Level Mode (Auto Power Off): When this operation mode is selected, the scanner continues to turn on the light source of the scanner before a good read or pre-defined
“Light Source on Time”. If the scanner decodes a bar code successfully, it turns off the light source immediately. After the scanner turns off the light source, you must press the trigger to turn on the light source again. If there is no scanning operation performed during the pre-defined light source on time, the scanner enters the idle state after the pre-defined light source on time is up.
FuzzyScan Laser model only have LED illumination (without laser aiming line) in Flash/ Force/Toggle/ Diagnostics Modes .
54
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Presentation Control
P.C
SS
SS
SS
Operation Control
(F & L Series)
Presentation Control, Scan Rate, Flash Duty
Parameter Selection
Presentation mode
Flash mode
Force mode
F_DEFAULT
Option Code
0
1
2
Scan Rate Control
SS
SS
Dynamic
Fixed
0
1
Flash Duty Cycle
SS
SS
SS
SS
1/2 duty cycle
2/3 duty cycle
3/4 duty cycle
4/5 duty cycle
0
1
2
3
SmartStand Power Off Timeout
SS
SS
SS
L680/L780 laser imagers don’t support this function.
3 mins
5 mins
10 mins
0
1
2
Only available for FuzzyScan Laser model
Presentation Control: When the scanner is placed on SmartStand, the scanner will be switched from hand-held scanning to hands free scanning automatically. Three hands scanning modes are available. You are recommended to use flash mode or force mode while under insufficient ambient light.
Scan Rate Control : The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on the move. But this may impact to the reading distance.
The Flash Duty Cycle is designed to control the flashing frequency of the light source.
The SmartStand Power Off Timeout is a pre-defined duration for scanner’s light source on time when the scanner is placed on SmartStand. While the scanner is placed on
SmartStand, the scanning-type will be switched from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will be off when the pre-defined duration is up.
55
Configure Your FuzzyScan
PROGRAM
Family Code Selection
LED Illumination Control
P.C
SS
SS
Operation Control
(L Series)
Laser Imager, LED Illumination Control
& LED Illumination Delay
Always on
Intelligent Mode
Only available for L Series.
F_DEFAULT
Option Code
0
1
LED Illumination Delay
SS
SS
SS
SS
SS
100 ms
150 ms
200 ms
250 ms
300 ms
Only available for L Series.
0
1
2
3
4
LED Illumination Control: When you enable “always on“, the LED illumination will be always on when you press the trigger. When you enable “intelligent mode”, the scanner will emit the laser aiming line first, the LED illumination will be turned on after the preset LED illumination delay. Intelligent mode is recommended to be used in regular ambient light environment.
56
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Laser Aiming Control
Operation Control
(F & L Series)
Laser Aiming Control , 1D Barcode Reading Direction
P.C
SS
SS
Parameter Selection
Disable
Enable
Only available for L Series.
F_DEFAULT
Option Code
0
1
1D Barcode Forward-reading
Indication
1D Barcode Backward-reading
Indication
SS
SS
MS
SS
SS
MS
None ◆
“S”
User defined character(1 character)
None
“X” ◆
User defined character(1 character)
1D Barcode Direction
Indication Transmission
SS
SS
SS
SS
Disable
Enable prefix direction mark transmission
Enable suffix direction mark transmission
Enable both prefix and suffix direction mark transmission
Laser Aiming Control : You can disable or enable laser aiming line when you scan PDF barcode .
0
1
2 〔 00-7F 〕
0
1
2 〔 00-7F 〕
2
3
0
1
57
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Operation Mode
Presentation Control
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Operation Control
(A Series)
Operation , Presentation and Illumination Control
Parameter Selection
Low Power mode (Low power triggering)
Trigger mode (External triggering)
Presentation mode (Auto detection)
Alternative mode (Periodic power off)
Force mode (Continued power on)
Toggle mode (Repeat reading)
Diagnostic mode (Test reading)
Level mode (Auto power off)
Multiple Read Mode
Presentation mode
Force mode
F_DEFAULT
Option Code
0
1
7
8
5
6
2
3
4
0
1
Illumination Control
SS
SS
Disable
Enable
0
1
Presentation Background Lighting
SS
SS
LEDs Off
LEDs On
0
1
Hand-Held Mode: Low power mode, Trigger mode, Alternative mode, Toggle mode, Level mode, Multiple read mode
Hand-Free Mode: Presentation mode, Force mode,
The Illumination Control is only available for hand-held mode.
Presentation Background Lighting Control: You can enable or disable presentation background lighting of the scanner according to the ambient light condition in presentation mode. When the ambient light is dim or dark, you can enable this function to turn on the scanner’s LED illumination at a dim level. This is helpful for scanner to detect the motion of scene.
58
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Aiming Control
Operation Control
(A Series)
Aiming Control,
Delay
Aiming & Decode Aiming Control
P.C
SS
SS
SS
Regular Aiming
Intelligent Aiming
Delay Aiming Control
Parameter Selection
F_DEFAULT
Option Code
0
1
2
Delay Aiming Time-out Control
Decode Aiming Control
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
200 ms
400 ms
800 ms
1 sec
2 secs.
3 secs.
4 secs.
1.5 secs.
Disable in Hand-Held mode
Enable in Hand-Held mode
Disable in Hand-Free mode
Enable in Hand-Free mode
6
7
4
5
2
3
0
1
2
3
0
1
The Aiming Control is only available for trigger mode. In Intelligent Aiming, the aiming light is turned on when the scanner is lifted. A trigger pull activates decoding process.
After 2 seconds of inactivity, the aiming light will be shut off. Delay Aiming Control allows a delay time for the operator to aim the scanner before the image is taken. During the delay time, the aiming light will be on, but the LED illumination won’t be turned on until the delay time is up.
The Delay Aiming Time-out Control is only available for trigger mode. You can use Delay Aiming Time-out Control to set the delay time.
59
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Center Alignment
SS
SS
SS
SS
SS
SS
Operation Control
(A Series)
P.C
Center Alignment, Unique Bar Code Reporting
Unique Bar Code Reporting, Batch Reading
Disable in Hand-Held Mode
Enable in Hand-Held Mode
Disable in Hand-Free Mode
Enable in Hand-free Mode
Disable
Enable
F_DEFAULT
Option Code
2
3
0
1
0
1
Unique Bar Code Reporting
Center Alignment: When this function is enabled, the scanner only decodes barcode(s) around aiming line.
Unique Bar Code Reporting: When this function is enabled, the scanner only outputs unique barcode when the trigger is pressed. This function is workable when Multiple
Read mode is selected.
60
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Batch Reading
P.C
Operation Control
(A Series)
Batch Reading
Unique Bar Code Reporting, Batch Reading
SS None
Batch Reading rule input ( 01-16 rules)
F_DEFAULT
Option Code
[FIN]
[Rules] [FIN]
Batch Reading : When this function is enabled, you can scan multiple barcodes one by one continuously upon one trigger event. The scanner reports a good read beep and indication only if all bar codes set by the “Batch Reading Rule” are read. Otherwise, the scanner reports an error beep and indication. The scanned data will be transmitted according to the preset sequence which is defined in “Batch Reading Rule” regardless the scanned order of those barcodes.
- Batch Reading function is only available Trigger Mode .
- Batch Reading is not available when Multiple Read Mode or Center Alignment is turned on.
-
Batch Reading Rule :
To set the Batch Reading rule
1.
2.
3.
Scan the PROGRAM symbol.
Scan the Batch Reading symbol (Family Code).
Use the Option Code to define the preset Batch Reading rule.
4.
Scan the FIN symbol.
5.
Scan the END symbol to save your Batch Reading rule.
Note: Scan the ABORT and END symbol to exit without saving any Batch Reading rule setting.
When you scan “None”, the preset Batch Reading Rule will be cancelled.
- Batch Reading Rule Syntax:
[n] [Element 1] FF [Element 2] FF [Element 3] FF …[Element n] FF
Where n is the number of elements in the overall rule. The number of elements is up to 16.
FF indicates the end of one element.
- Element structure:
[Cino ID Hex value] [Code length] [Character match(es)]
Where:
[Cino ID Hex value]
Length: 2 byte
Please find Cino ID hex value from Symbology ID Table in appendix. Locate the Hex value for the symbology and scan the 2 digit hex values from the Option
Code .
Note: 99 is the universal number, indicating all symbologies.
61
Configure Your FuzzyScan
[Code length]
Length: 4 byte
Specify what length of data output will be acceptable for this symbology. When you calculate the length, you must consider the whole data string which includes the programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffix Symbol ID or AIM ID. Scan the four digit data length from the Option Code .
Note: 40 characters is entered as 0040; 9999 is a universal number, indicating all lengths.
[Character match]
Length: 2-8 byte
You can refer to HEX/ASCII Reference Table to find the Hex value that represents the character(s) you want to match. Use the Option Code to scan the alphanumeric combination that represents the ASCII characters. You can match up to 4 characters which are counted from the start character of the whole Data
String .
Note: When setting the matched character(s), you must match the content of the whole Data String, including the programmed Preamble, Postamble, Scanned
Data Length, Prefix/Suffi Symbol ID OR AIM ID if you had defined. FF is the universal character, indicating all characters.
- Batch Reading rule example
In this example, you are scanning Code 39, Code 128, and Code 93 bar codes, but you would like to output the data in following sequence:
Code 128 - Code 39 - Code 93
B-CODE39
A-CODE128
C-CODE93
62
Configure Your FuzzyScan
You would set up the Batch Reading rule with the following command line:
[PROGRAM] [Batch Reading] [0301999941FF07999942FF09999943FF] [FIN] [END]
The breakdown of the command line is shown below:
03
01
9999
41
FF
07
9999
42
The number of elements in the overall rule
Code identifier of Code 128
Code length that must match for Code 128, 9999 = all lengths
Start character match for Code 128, 41h = “A”
End of first code
Code identifier of Code 39
Code length that must match for Code 39, 9999 = all lengths
Start character that must match for Code 39, 42h = “B”
FF
09
9999
43
End of second code
Code identifier of Code 93
Code length that must match for Code 93, 9999 = all lengths
Start character match for Code 93, 43h = “C”
FF End of third code
To program the previous example using specific lengths, you would have to count the programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffix
Symbol ID OR AIM ID if you had defined as part of the length. If you enable the Suffix Symbol ID of symbology, you would add one character to the previous example’s length.
You would set up the Batch Reading rule with the following command line:
[PROGRAM] [Batch Reading] [0301001041FF070009FF09000943FF] [FIN] [END]
63
Configure Your FuzzyScan
The breakdown of the command line is shown below:
03
01
0010
41
FF
07
0009
FF
09
0009
The number of elements in the overall rule
Code identifier of Code 128
Code length that must match for Code 128
A-CODE128 sample length (9) plus Suffix Symbol ID (1) = 10
Start character match for Code 128, 41h = “A”
End of first code
Code identifier of Code 39
Code length that must match for Code 39
B-CODE39 sample length (8) plus Suffix Symbol ID (1) = 9
Universal matched character, indicating all character
Also indicate end of second code
Code identifier of Code 93
Code length that must match for Code 93
C-CODE93 sample length (8) plus Suffix Symbol ID (1) = 9
Start character match for Code 93, 43h = “C” 43
FF End of third code
Note: If the [Character match(es)] is set to “FF”, the following “FF” which indicated the end of the code was not need to set.
- Structure of Data String
STX
(RS232/USB COM interface)
1 character
Preamble
1-15 characters
Scanned Data
Length
2-4 digits
Prefix Symbol ID
Or
Prefix AIM Symbol ID
1 or 3 characters
Scanned Data modified by DataWizard
Variable length
Suffix Symbol ID
Or
Suffix AIM Symbol ID
1 or 3 characters
Postamble
1-15 characters
ETX
(RS232/USB COM interface)
1 character
64
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Buzzer Tone Adjust
Power On Indicator
Operation Control
(All Series)
Buzzer, Indicator & Vibrator Control
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Buzzer tone – mute
Buzzer tone – low (Frequency 1.20 kHz)
Buzzer tone – medium (Frequency 2.70 kHz)
Buzzer tone – high (Frequency 2.81 kHz)
Buzzer tone - extremely high (Frequency 2.93 kHz)
Power-on beep
No power-on beep
Disable (LED off)
LED steady on
LED flash
F560 series scanner doesn’t support this function.
Disable
Enable
Good Read Indicator
Vibrator Control
SS
SS
Disable
Enable
Optional function is only available for vibrator model.
Buzzer Tone Adjust:
Available firmware: A680 / A780 1.00.01 and above
A770 rev.1.00.26, rev. 2.00.10 and above
A670 rev 1.00.07 and above
F680 / L680 rev.2.01.12 and above
F780 / L780 rev.2.01.12 and above
F560 rev. 2.01.14 and above
65
F_DEFAULT
Option Code
4
5
2
3
0
1
1
2
6
0
0
1
0
1
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Buzzer Volume
P.C
SS
SS
SS
Low
Medium
High
Buzzer Volume:
Available firmware: A680 / A780 1.00.01 and above
A770 rev. 1.00.21, rev. 2.00.04 and above
A670 rev 1.00.03 and above
Operation Control
(A Series)
Buzzer Volume
Parameter Selection
F_DEFAULT
Option Code
0
1
2
66
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Redundancy
1D Barcode Inverse Reading
P.C
SS
SS
SS
SS
SS
SS
SS
SS
Operation Control
(All Series)
Redundancy & 1D Code Inverse Reading
Parameter Selection
None
Level 1
Level 2
Level 3
Level 4
Level 5
To prevent potential miss reading.
Disable
Enable
The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.
67
F_DEFAULT
Option Code
0
3
4
1
2
5
0
1
Configure Your FuzzyScan
PROGRAM
Operation Control
(All Series)
Reread Delay & Good Read Delay Control
F_DEFAULT
Family Code Selection
Reread Delay
(Double Scan Verification)
P.C
SS
SS
SS
SS
SS
SS
Disable
Immediate time out
Short time out
Medium time out
Long time out
Force verification
Parameter Selection Option Code
4
5
2
3
0
1
Good Read Delay
SS
SS
SS
SS
SS
SS
SS
None
200 msec.
500 msec.
1 sec.
1.5 sec.
2 sec.
3 sec.
0
3
4
1
2
5
6
The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification will not allow reading of the same bar code twice.
This Good Read Delay is the minimum amount of time before the imager can read another bar code.
68
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Light Source On Time
P.C
SS
SS
SS
SS
Operation Control
(All Series)
Light Source On Time, Hands Free Time-out
Parameter Selection
Short
Medium
Long
Extremely long
F_DEFAULT
Option Code
0
1
2
3
Hands Free Time-out
Good Read Duration
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Short
Medium
Long
Extremely long
Disable
Short
Medium
Long
Extremely long
Extremely short
2
3
4
0
1
0
1
2
3
4
Time Delay to Low Power Mode
SS
SS
SS
1 sec
3 secs
5 secs
0
1
2
SS
SS
7 secs
9 secs
3
4
SS Immediate 5
The Light Source On Time is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on till the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.
The Presentation Mode, Force Mode and Flash Mode are referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode when you press the trigger. You can remain the scanner in manual trigger mode by setting the Hands Free Time-Out . Once the time-out duration is up (if there’s no any trigger operation), the imager will revert to the original hands free mode.
The Time Delay to Low Power Mode sets the time for scanner to enter low power mode after any scanning activity. This setting is only available for the scanner is in low power mode.
69
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Presentation Auto-sense
P.C
SS
SS
Operation Control
(All Series)
Presentation Auto-Sense & Sensitivity
& Sensitivity Settings
Disable
Enable
F_DEFAULT
Option Code
0
1
Presentation Sensitivity
SS
SS
SS
SS
SS
SS
SS
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
0
1
2
3
4
5
6
When enabling the Presentation Auto-sense, the scanner can be switched from hand-held and hand-free scanning automatically when working with the SmartStand. the barcode.
70
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Preamble
Postamble
Data Length Transmission
Condensed DataWizard
Preamble, Postamble, Data Length & Symbol ID Trans.
P.C
SS
MS
Parameter Selection
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
SS
MS
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
SS
SS
Disable
Enable 2~4 digits data length transmission
F_DEFAULT
Option Code
FIN
[00-7F], [FIN]
FIN
[00-7F], [FIN]
0
1
Symbology ID Transmission
SS
SS
SS
SS
Disable symbology ID transmission
Enable prefix symbology ID transmission
Enable suffix symbology ID transmission
Enable both prefix and suffix symbology ID transmission
0
1
2
3
SS
SS
Enable prefix AIM symbology ID transmission
Enable suffix AIM symbology ID transmission
4
5
SS Enable both prefix and suffix AIM symbology ID transmission 6
DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard, you can process the scanned data prior the transmissions in many ways as: Insert , Delete , Match , Verify , Replace , Reorganize , and Repeat Transmission . It will help you to arrange the transmission of scanned data to any specific format without software modification.
Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool . Through the PowerTool, all settings and configurations can be done on-screen on Windows 2000 / XP / 7
A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with ease.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.
71
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Formatter Control
P.C
SS
MS
MS
Condensed DataWizard
Data Formatter Setting
Parameter Selection
Disable
Select one bar code symbology
Select all bar code symbologies
F_DEFAULT
Option Code 2nd Option Code
FIN
(2 digits)
00 automatic termination automatic termination
1st Insertion
2nd Insertion
SS
DS
SS
DS
Disable
Enable
2-digits identified position; max. 3 insertion characters
Disable
Enable
2-digits identified position; max. 3 insertion characters
Disable
Enable
FIN
(2 digits) position
FIN
(2 digits) position
[1-3 characters], [FIN]
[1-3 characters], [FIN]
3rd Insertion
SS
DS
FIN
(2 digits) position
[1-3 characters], [FIN]
4th Insertion
SS
DS
2-digits identified position; max. 3 insertion characters
Disable
Enable
FIN
(2 digits) position
[1-3 characters], [FIN]
2-digits identified position; max. 3 insertion characters
The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.
While the Data Formatter is enabled, it arranges only scanned data without Preamble , Postamble , STX , ETX , Data Length , Prefix/Suffix Symbology ID or Record Suffix .
All of the above programmable parameters perform the same function depending on your setting.
Regarding the “ Bar Code Selection ” and “ Position Calculation ” of data formatter, please refer to page 75 for details.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
72
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Verifier Control
P.C
SS
MS
MS
Condensed DataWizard
Data Verifier Setting
Parameter Selection
Disable
Select one bar code symbology
Select all bar code symbologies
F_DEFAULT
Option Code 2nd Option Code
FIN
(2 digits)
00 automatic termination automatic termination
Identified Data Length
1st Identified Character
2nd Identified Character
SS
DS
SS
DS
SS
DS
Disable
Enable
Determine the identified data length for verification.
Disable
Enable
2-digits checking position; 1 identified character
Disable
Enable
2-digits checking position; 1 identified character
FIN
(2 digits)
FIN
(2 digits) position
FIN
(2 digits) position
[00-7F]
[00-7F]
3rd Identified Character
SS
DS
Disable
Enable
2-digits checking position; 1 identified character
FIN
(2 digits) position
[00-7F]
The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter .
All data must conform to the Identified Bar Code Symbologies , Identified Data Length , and one to three Identified Characters in the checking position. Otherwise, the
FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.
The Data Verifier checks only scanned data without Preamble , Postamble , STX , ETX , Data Length , Prefix/Suffix Symbology ID or Record Suffix .
Regarding the “ Bar Code Selection ” and “ Position Calculation ” of Data Verifier , please refer to page 75 for details.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
73
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Replacer Control
P.C
SS
MS
MS
Condensed DataWizard
Data Replacer Setting
Parameter Selection
Disable
Select one bar code symbology
Select all bar code symbologies
F_DEFAULT
Option Code 2nd Option Code
FIN
(2 digits)
00 automatic termination automatic termination
1st Replacement
SS
DS
Disable
Enable
2-digits identified position; 1 replacement character
FIN
(2 digits) position
[00-7F]
2nd Replacement
SS
DS
Disable
Enable
2-digits identified position; 1 replacement character
FIN
(2 digits) position
[00-7F]
3rd Replacement
SS
DS
Disable
Enable
2-digits identified position; 1 replacement character
FIN
(2 digits) position
[00-7F]
The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for replacer control, and provides Multiple Position Replacement in the identified position.
All data must conform to the Identified Bar Code Symbologies , and one to three Identified Characters in the identified position. While the Data Replacer is enabled, it arranges only scanned data without Preamble , Postamble , STX , ETX , Data Length , Prefix/Suffix Symbology ID or Record Suffix .
Regarding the “ Bar Code Selection ” and “ Position Calculation ” of Data Replacer, please refer to page 75 for details.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
74
PROGRAM
Family Code Selection
Organizer Control
Configure Your FuzzyScan
P.C
SS
MS
MS
Condensed DataWizard
Data Organizer Setting
Parameter Selection
Disable
Select one bar code symbology
Select all bar code symbologies
F_DEFAULT
Option Code 2nd Option Code
FIN
(2 digits)
00
Automatic termination
Automatic termination
1st Organization
2nd Organization
Include/Exclude Control
SS
DS
SS
DS
SS
DS
Disable
Enable
2-digits identified position;
Forward/backward data transmission setting
Disable
Enable
2-digits identified position;
Forward/backward data transmission setting
Transmitted data excluded the data of identified position
Transmitted data included the data of identified position
FIN
(2 digits) position direction
FIN
(2 digits) position direction
0
1
0 (Forward)
1 (Backward)
0 (Forward)
1 (Backward)
The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward . It also allows you to control the transmitted data including or excluding the data of identification position. Please refer to the application example listed in page 75 for details.
While the Data Organizer is enabled, it arranges only scanned data without Preamble , Postamble , STX , ETX , Data Length , Prefix/Suffix Symbology ID or Record
Suffix .
Regarding the “ Bar Code Selection ” and “ Position Calculation ” of Data Organizer, please refer to page 75 for details.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table .
75
Configure Your FuzzyScan
Select a Bar Code Symbology
You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the
FuzzyScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below.
Code 128
GS1-128
UPC-A
UPC-A with 2 supplement
UPC-A with 5 supplement
UPC-E
UPC-E with 2 supplement
UPC-E with 5 supplement
EAN-13
EAN-13 with 2 supplement
EAN-13 with 5 supplement
EAN-8
EAN-8 with 2 supplement
EAN-8 with 5 supplement
Codabar/NW-7
Code 39
Code 32
Trioptic Code 39
1D Bar Code Symbology
01 Matrix 2 of 5
31 Interleaved 2 of 5
02 China Postal Code
32 German Postal Code
42 Standard/Industrial 2 of 5
03 Code 93
33 Code 11
43 MSI/Plessey
04 UK/Plessey
34 Telepen
44 GS1 DataBar
05 GS1 DataBar Limited
35 GS1 DataBar Expanded
45 Composite Codes
06 IATA
07 Coupon Code
37 PDF417
47 Micro PDF417
Codablock F
Code 16K
Code 49
23
24
15
16
17
25
18
19
20
10
11
12
13
14
22
38
48
58
68
08
09
QR Code
MicroQR Code
DataMatrix
GS1 DataMatrix
2D Bar Code Symbology
A0 MaxiCode
A0 Aztec Code
A1 Chinese Sensible Code
A5
Korea Post Code
Australian Post
British Post
Intelligent Mail barcode
Position Calculation
[Data Formatter]
Postal Code
21 Japanese Post
B0 KIX Post
B1 Planet Code
B3 Postnet
If there is a 5-character input data string, refer to the following to calculate the actual position for insertion:
B4
B5
B6
B8
A2
A3
A4
00
X
01
X
02
X
03
X
04
X
05
[Data Verifier, Data Replacer, Data Organizer]
If there is a 11-character data string, please refer to the following to calculate the actual position for identification.
X X X X X X X X X X X
00 01 02 03 04 05 06 07 08 09 10
76
Configure Your FuzzyScan
Application Example
If your bar code label is a 16-digit Interleaved 2 of 5 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price, you want the FuzzyScan do the following for you without software modification:
Apply only Interleaved 2 of 5 to the condensed
DataWizard.
Check bar code is actually with 16-digit length.
Allow bar code output whose date code is leading with “9”.
Three outputs with “TAB” suffix.
The date code outpu t should skip “9” and replaced it by
“A”.
The serial number output should be led with “SN”.
The unit price output should be skipped the first 2 digits.
Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6
Actual Output : A81025[TAB]SN123456[TAB]76[TAB]
Programming Procedure
[Data Verifier]
Scan “Program” to enter the programming mode.
Scan “Verifier Control” and set bar code symbology to
“ 48 ” (Interleaved 2 of 5).
Scan “Identified Data Length” and set the length to
“ 16 ”.
Scan “1st Identified Character” and set the identified position to “ 00 ”, then set the identified character to “ 39 ”
(Hex Code of 9).
[Data Formatter]
Scan “Formatter Control” and set bar code symbology to “ 48 ”.
Scan 1st Insertion” and set the identified position to
“ 06 ”, then inserted characters to “ 09 ” (Hex Code of
TAB), “ 53 ” (Hex Code of S), “ 4E ” (Hex Code of N).
Scan “2nd Insertion” and set the identified position to
“ 12 ”, then inserted character to “ 09 ”. In the final, you must scan “ FIN ” (Finish) code to terminate this selection.
Scan “3rd Insertion” and set the identified position to
“ 16 ”, then inserted character to “ 09 ”. In the final, you must scan “
FIN
” (Finish) code to terminate this selection.
77
Configure Your FuzzyScan
[Data Replacer]
Scan “Replacer Control” and set bar code symbology to
“ 48 ”.
Scan “1st Replacement” and set the identified position to
“ 00 ”, then replaced character to “ 41 ” (Hex Code of A).
[Data Organizer]
Scan “Organizer Control” and set bar code symbology to
“
48
”.
Scan “1st Organization” and set the identified position to
“ 16 ”, then set the data transmission to “ 0 ” (forward).
Scan “2nd Organization” and set the identified position to
“
17
”, then set the data transmission to “
1
” (backward).
Scan “
END
” (Exit) to terminate the programming.
[Important Notice]
Please note that Condensed DataWizard will follow the preset working flow as below:
Verifier Formatter Replacer Organizer
So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter.
78
Appendix
Symbology ID Table
Each AIM Code Identifier contains the three-character string ]cm where:
] = Flag Character; c = Code Character; m = Modifier Character
Code Family
UPC
Code 128
Codabar
Code 25
IATA
UCC Coupon
1D Symbology ID Table
Cino ID AIM ID
Primary Format
UPC-A
UPC-A with 2 supple.
UPC-A with 5 supple.
UPC-E
Modified
Char.
UPC-E with 2 supple.
UPC-E with 5 supple.
33
43
E
Example: A UPC-A bar code 012345678950 with 2 supplement 12 is transmitted as ]E0 012345678950 ]E1 12
1
2
Code 128
GS1-128
Codabar/NW-7
Standard/Industrial 2 of 5
Matrix 2 of 5
Interleaved 2 of 5
Hex
Value
2
32
42
3
01
31
06
08
38
Char.
A
B
C
D
I
K
Code
Char.
E
C
F
S
X
0
1
2
0 m
1 m
0
0
48 J I m
China Postal Code
German Postal Code
IATA
UCC Coupon Code
58
68
15
Z
L
M
O
X
I
R
0 m m
Example : A UPC-A 512345678900 + GS1-128 81010123451297 bar code is transmitted as ]E0 512345678900 ]C1 81010123451297
Example: A EAN-13 9923456789019 + GS1-128 81010123451297 bar code is transmitted as ]E0 9923456789019 ]C1 81010123451297
Cino ID AIM ID
Code Family
EAN/JAN
Code 93
Code 11
UK/Plessey
Telepen
Primary Format
EAN/JAN-8
EAN/JAN-8 with 2 supple.
EAN/JAN-8 with 5 supple.
EAN/JAN-13
EAN/JAN-13 with 2 supple.
EAN/JAN-13 with 5 supple.
34
44
F E 1
2
Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is transmitted as ]E4 49123562 ]E2 12345
Code 93
Code 11
MSI/Plessey MSI/Plessey
UK/Plessey
Telepen
GS1 Databar
Hex
Value
05
35
45
04
09
10
11
12
13
14
Char.
N
H
P
R
S
T
Code
Char.
E
G
H
M
P
B
Modified
Char.
4
1
2
0 m m m
0 m
GS1 DataBar
Composite
Code 39
PDF417
Codablock
Korea Post
GS1 DataBar Limited
GS1 DataBar Expanded
Composite Code
Code 39
Code 39 Trioptic
Code 32
PDF417
Micro PDF417
Codablock F
Korea Post Code
22
23
24
07
47
37
17
25
18
21
X
G
W
G
V
Y a
Remark: Above examples are given for the transmission of AIM ID. e
A
X
A
L
O
X m m
0
0 m m
0
79
Appendix
Code Family Primary Format
QR Code
Micro QR
Code
QR Code
Micro QR Code
Data Matrix
MaxiCode
Aztec Code
Data Matrix
GS1 Data Matrix
MaxiCode
Aztec Code
Chinese
Sensible
Chinese Sensible
Australian Post Australian Post
Cino ID
Hex
Value
Char.
A0
A1
A5
A2
A3
A4
B0 b c f g d e
Code
Char.
2D Symbology ID Table
AIM ID
Modified
Char.
Code Family
Q d
U z m m m m
Primary Format
British Post
Intelligent
Mail barcode
Japanese
Post
British Post
Intelligent Mail barcode
Japanese Post
KIX Post KIX Post
Planet Code Planet Code
Postnet
X
0
0
Postnet
B4
B5
B6
B8
Cino ID
Hex
Value
B1
Char. h
B3 j
Code
Char.
AIM ID
Modified
Char.
0
0 k l m o
X
0
0
0
0
80
Appendix
Keyboard Function Code Table
11
12
13
14
07
08
09
10
15
03
04
05
06
No.
00
01
02
VT
FF
CR
SO
BEL
BS
HT
LF
SI
ANSI
NUL
SOH
STX
ETX
EOT
ENQ
ACK
07H
08H
09H
0AH
0BH
0CH
0DH
0EH
0FH
ASCII
00H
01H
02H
03H
04H
05H
06H
Key Function
RESERVED
CTRL (Left)
ALT (Left)
SHIFT
CAPS LOCK
NUM LOCK
ESC
F1
BACK SPACE
TAB
F2
F3
F4
ENTER (CR)
F5
F6
Ctrl Output
Ctrl + @
Ctrl + A
Ctrl + B
Ctrl + C
Ctrl + D
Ctrl + E
Ctrl + F
Ctrl + G
Ctrl + H
Ctrl + I
Ctrl + J
Ctrl + K
Ctrl + L
Ctrl + M
Ctrl + N
Ctrl + O
27
28
29
30
23
24
25
26
31
19
20
21
22
No.
16
17
18
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
ANSI ASCII
DLE 10H
DC1
DC2
11H
12H
DC3
DC4
NAK
SYN
13H
14H
15H
16H
17H
18H
19H
1AH
1BH
1CH
1DH
1EH
1FH
Key Function
F7
F8
F9
F10
F11
F12
INS (Insert) (Edit)
DEL (Delete) (Edit)
HOME (Edit)
END (Edit)
PAGE UP (Edit)
PAGE DOWN (Edit)
UP (Edit)
DOWN (Edit)
LEFT (Edit)
RIGHT (Edit)
Ctrl Output
Ctrl + P
Ctrl + Q
Ctrl + R
Ctrl + S
Ctrl + T
Ctrl + U
Ctrl + V
Ctrl + W
Ctrl + X
Ctrl + Y
Ctrl + Z
Ctrl + [
Ctrl + \
Ctrl + ]
Ctrl + 6
*see note
To emulate the keyboard function key input for user definable parameters, user must configure actual content using the
Reserved ASCII 00 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP,
COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.
The last character in the Ctrl Output column is varied for different countries.
Country (refer to Keyboard Layout) & Character
United State - Switzerland
Belgium
Sweden
Spain
-
-
-
UK
Denmark
Italy
-
-
-
-
France
Germany
Norway -
=
-
81
ASCII Input Shortcut
To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the
“ HEX/ASCII Table ” for details.
Example:
If you want the scanned data output leading with a Dollar
Sign, you have to set the “Preamble” to “$”. The configuration procedure is listed below for reference.
Scan the system command – PROGRAM listed on page
3-24 to enter programming mode.
Scan family code – PREAMBLE to select this family.
Refer to the Hex/ASCII Table , you will find the HEX value of “ $ ” is 24 .
Scan the option code – 2 listed on the fold out back cover.
Scan the option code – 4 listed on the fold out back cover.
Scan the system command – FIN (Finish) to terminate
Preamble setting.
Scan the system command – End to exit the programming mode for normal operation.
Appendix
HEX/ASCII Reference Table
H
L
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0 1 2 3 4 5
T
U
V
W
X
P
Q
R
S
\
]
^
Y
Z
[
_
6
FF
CR
SO
HT
LF
VT
SI
NUL DLE SPACE 0
SOH DC1 ! 1
STX DC2
ETX DC3
"
#
2
3
EOT DC4
ENQ NAK
ACK SYN
BEL
BS
ETB
CAN
$
%
&
'
(
4
5
6
7
8
EM
SUB
ESC
FS
GS
RS
US
,
-
.
)
*
+
/
<
=
>
9
:
;
?
G
H
D
E
F
@
A
B
C
L
M
N
I
J
K
O
Example : ASCII “A” HEX “41”; ASCII “a” “61” d e f g h b c
` a l m n i j k o
7 t u v w x r s p q
|
}
~ y z
{
DEL
: High Byte of HEX Value
: Low Byte of HEX Value
82
Appendix
Host Interface Quick Set
RS232 Serial
USB HID Standard Mode
Keyboard Replacement
USB HID Turbo Mode
PS/2 (DOS/V) KBW Standard Mode
PS/2 (DOS/V) KBW Turbo Mode
USB HID Legacy Mode USB Com Port Emulation
83
Appendix
Operation Mode Quick Set (F & L Series)
Low Power (Low power trigger)
Alternative (Periodic power off)
Trigger (External triggering)
Flash (Pulse driven reading)
Presentation (Auto sensing)
Level (Auto power off)
84
Force (Continued power on)
Toggle (Repeat reading)
Diagnostic (Test reading)
Operation Mode Quick Set (A Series)
Appendix
Low Power (Low power trigger)
Alternative (Periodic power off)
Trigger (External triggering)
Level (Auto power off)
Presentation (Auto sensing)
Multiple Read
85
Force (Continued power on)
Toggle (Repeat reading)
Diagnostic (Test reading)
Option Codes
0
1
3
2
4
FIN (Finish)
9
6
7
5
8
Appendix
Abort
D
C
E
A
B
F
END (Exit)
86
Appendix
System Commands
PROGRAM
(Enter Programming Mode)
FIN (Finish)
Save User Default
User Default
System Information List
(SYSLIST)
PowerTool Host Link
END
(Exit Programming Mode)
Factory Default
Master Default
Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value.
Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection , Keyboard Interface
Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), and Wand/Laser Emulation
Control , the rest of parameters will be returned to default value.
User Default: After scanning” Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and would like to return to previous setting, please scan “User Default”.
87
Appendix
88

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Reads 1D and 2D barcodes
- Fast and accurate scanning
- User-friendly features
- Durable construction
- Long battery life
- Supports USB, RS-232, and Bluetooth interfaces
- Can be used in handheld or presentation mode
- Features a large scanning window and a bright aiming beam
- Includes a variety of configuration options to meet your specific needs