Vulcan V200 on-board scale system Service manual
The Vulcan V200 on-board scale system is designed to measure the gross vehicle weight and net payload weight of trucks and trailers. It uses load cells and pressure sensors to measure the weight of the vehicle and its load. The system includes a meter that displays the weight readings, and a Vulcoder that transmits the weight data from the load cells to the meter. The V200 is easy to calibrate and maintain, making it a reliable and accurate weighing system.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
CONTENTS
V200 SERVICE MANUAL
Table of Contents
1
......................................................3
.......................................................................................9
....................................................................11
.............................................................13
4.1 Procedure For Entering Starting Calibration Numbers.......................................13
4.3 Calibration Procedure For Gross Vehicle Weight Methods................................16
.............................................................................................21
5.2 Preventive Maintenance And Vulcan Torque Specifications..............................23
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
2 CONTENTS
..................................................................................... 29
6.2.4 Vulcoder Check-Out Procedure ..............................................................36
6.4.1 No Indicator Display Or Functioning Lights.............................................40
6.4.2 Unable To Enter Tare Or Calibration Numbers.......................................41
6.4.3 Meter Reading Drifts Or Wanders With Time .........................................42
6.4.4 Meter Reading Does Not Change When Truck Is Being Loaded............44
6.6 Troubleshooting Assistance And Replacement Parts ........................................47
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 1 3
C H A P T E R 1 . 0
VULCAN V200 ON-BOARD SCALE SYSTEM
Vulcan On-Board Scales are installed on all types of vehicles including, hook lifts, logging trucks, flatbed trailers, chip trailers, and many other commercial vehicles requiring scales. Total truck payload weights and gross vehicle weights can be measured using the Vulcan On-Board Scale System.
Typically a scale system has either four or six load cells, two Vulcoders, and one meter per truck. The number of load cells required depends on the truck’s length and the load capacity.
Vulcan Scale System
Vulcoders
Meter
Figure 1-A Typical Long Logger System
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
4 CHAPTER 1
Vulcan load cells and pressure sensors are machined from solid blocks of high strength steel. The
Strain gages are bonded inside the load cell or pressure sensor to sense extremely small dimensional changes in the material. A strain gage is a precision electrical resistance element. When force is applied to these sensors, the strain gages stretch or compress, causing a change in output signal voltage.
Example: Vulcan Super - Beam Load Cell
January 2004
Figure 1-B: Vulcan Super - Beam Load Cell
(Covered by one or more of the following patents:
US Patent RE. 35,301, 4,459,863
Canadian Patent 1,245,677)
VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 1
1.2 VULCODERS
The primary functions of the Vulcoder are to supply the load cells with power and to relay the load cells’ output to the meter. The Vulcoder receives a 12 Vdc input from the meter and supplies the load cells with 7.5 Vdc +/- .5 Vdc. When weight is applied, the voltage output of the load cells change.
The Vulcoder then reads the change in voltage from the load cells and converts it from an analog to a digital signal. This signal is then relayed to the meter and displayed as weight.
5
Figure 1-C: Vulcan Electronics Diagram
1.3 METER
The V200 meter’s primary functions are to supply the Vulcoder with 12 Vdc and to read the digital signal transmitted from the Vulcoder. The meter reads the digital signal, makes calculations, and displays a weight in pounds or kilograms. The V200 meter is shown on the following page together with a description of the meter button functions.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
6 CHAPTER 1
Figure 1-D: V200 Meter
POWER BUTTON:
Turns the meter on and off.
UP/ DOWN ARROW BUTTONS:
Used to increase or decrease the Cal Number and Tare Number.
CYCLE BUTTON:
Used to view the weight on different channels.
CAL BUTTON:
Used to view and adjust the Cal Number for a particular channel.
TARE BUTTON:
Used to view and adjust the Tare Weight for a particular channel.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 1 7
1. Tape Vulcoder connectors prior to routing cabling to avoid contamination. Mount Vulcoders on inside of truck frame rail or next to a structural member. Mounting surface must be in an area protected from road or hauling debris.
5.
2.
3.
Route black cable to load cells. (Do not trim black cable to length).
Important: Check connectors to make sure they are clean and dry. Turn meter off while making any wire connections. Do not get moisture, contact cleaner, or any other substance inside of connectors.
4. Check load cell connector coming from the Vulcoder for O-ring. Attach black cable connectors to bulkhead connectors on load cells. Make sure they are finger tight plus an additional 1/8 of a turn with channel lock pliers. The additional tightening is necessary to compress O-ring preventing scale errors, which can occur from moisture entering into the load cell connector. Caution: Do not over tighten the connectors as this can damage them.
Route orange Vulcoder cable to cab.
Note: On truck-to-trailer connection, these wires may be routed using the existing truck / trailer wire harness if two unused, ungrounded wires are available. Additionally, you may follow the existing wire harness and use a separate connector of your choice between the truck and trailer.
6. Find suitable location for the meter and install mounting bracket. Secure cable so it does not obstruct other in cab equipment, strain relief Vulcoder orange cable, and cut to length. Unplug terminal block from back of meter, strip wires, and make all wire connections to terminal block
(refer to Figures 1-E and 1-F). Do not plug terminal block into meter at this time.
7. Disassemble positive fuse holder, (red wire). Connect fused power leads directly to battery for best operation. If not connecting directly to the battery be sure to use a location that has the proper 12 Vdc available at all times, refer to Section 7.4 “System Specifications.”
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
8 CHAPTER 1
Note: Some trucks are configured with variable voltage supplies, never apply more than 16
Vdc to the Vulcan system. Apply grease to the positive connector at the battery post to inhibit corrosion.
8. Review steps 1 to 7 before connecting terminal block to back of meter.
Figure 1-E: Stripping Wires for Meter
Figure 1-F: Wire Connections to Meter
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 2
C H A P T E R 2 . 0
METER OPERATION
2.1 TURNING THE METER ON
This can be done by pressing the Power button on the meter.
2.2 LOCKING THE METER ON A PARTICULAR CHANNEL
To lock the meter on a particular channel, press the Cycle button until the channel light is displayed. Press the Cycle button again, the meter is now locked on a specific channel.
Channel Designations for Figures 2-A and 2-B.
Channel A : Represents the truck or front load cells, regardless of whether it is a four or a six
Channel B: Represents the trailer or rear load cells.
Channel A+B: Represents the total weight from the front and rear load cells.
2.3 DISPLAYING TARE WEIGHT
Lock the meter on Channel A or B. The Tare Weight is the displayed reading when the vehicle is empty. For setting the Tare Weight, refer to Chapter 4.0 “Calibration and System Set-up”.
2.4 DISPLAYING CALIBRATION NUMBERS
Lock the meter on Channel A or B. Press and hold the Cal button to display the Calibration
Number. For setting the Calibration Numbers, refer to Chapter 4.0 “Calibration and System
Set-up”.
9
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
10 CHAPTER 2
Figures 2-A and 2-B: Vulcan 4 and 6 cell configurations
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 3
C H A P T E R 3 . 0
WEIGHT MEASURING METHODS
The Vulcan Scale System can be used to measure weight by two different methods. These methods are Gross Vehicle Weight, and Net Payload Weight.
3.1 GROSS VEHICLE WEIGHT
Gross Vehicle Weight : Entire truck weight including fuel, equipment, personnel,
11
In order to use the Gross Vehicle Weight method, the Tare Weight for Channel A and Channel B must be entered. The Tare Weight is the weight of the empty truck with fuel, equipment, personnel and no
payload. For example if the Tare Weight is 30,000 lb, the meter will display this weight before any payload has been loaded. As the payload increases, the weight displayed on the meter will also increase. The weight displayed on Channel A at all times is the Gross Truck Weight. The weight displayed on Channel B at all times is the Gross Trailer Weight and the weight displayed on Channel
A + B is the Total Gross Vehicle Weight (truck and trailer).
3.2 NET PAYLOAD WEIGHT
Net Payload Weight: Weight of the truck’s payload only.
By using the Net Payload Weight method, payload pickups are measured cumulatively. Net Payload
Weight can be measured when the truck’s Tare Weight is set to zero. If the Tare Weight for Channel
A and Channel B are set to zero, the weight displayed at all times during the route is the Net Payload
Weight.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
12 CHAPTER 3
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 4 13
C H A P T E R 4 . 0
CALIBRATION AND SYSTEM SET-UP
Calibration is fine tuning a system to maximum accuracy in reference to a specific certified platform scale. It is important to calibrate for high accuracy in order to achieve the maximum possible payload.
It is also important that conditions remain as constant as possible throughout the calibration process.
Inaccuracies may result from differences in fuel load, ice build-up, etc. It may take 2 or 3 attempts at calibration to achieve the optimum setting.
Calibration should be done anytime a system is installed, if there are continuous questionable readings, or if meter readings repeatably do not closely match the certified platform scale weights.
The Vulcan Scale System can be calibrated for Gross Vehicle Weight and Net Payload Weight. The
Net Payload Weight displays only the weight of the payload and the Gross Vehicle Weight displays the weight of both the truck and its payload.
4.1 PROCEDURE FOR ENTERING STARTING
4.
3.
1. Stop the empty truck on level ground.
2. Turn on the meter. Wait for system initialization.
Look up Cal Numbers for Channel A and B in Section 7.1
“Starting Calibration Numbers” and write them in the space provided below.
Starting Channel A Cal Number: ________ Starting Channel B Cal Number : _________
Lock meter on Channel A using the Cycle button.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
14 CHAPTER 4
5. Press and hold Cal button to display Cal Number setting. If setting does not match starting
Channel A Cal Number in Step 3, correct the Cal Number with the Up or Down Arrow
7.
change.
6. Lock the meter on Channel B using the Cycle button.
Press and hold Cal button to display Cal Number setting. If setting does not match starting
Channel B Cal Number in Step 3, correct the Cal Number with the Up or Down Arrow
change.
8.
IMPORTANT
: Leave the meter on for a minimum of 3 minutes after changing the Cal
Numbers so the new values will be recorded into permanent memory. Starting the truck or turning the ignition switch during this time will cause the meter to reset and go back to a
2.
3.
4.2 PROCEDURE FOR ENTERING TARE WEIGHTS
1.
GROSS VEHICLE WEIGHT METHOD
Weigh the entire empty truck (both front and rear axles) using a certified platform scale. This is the truck’s Tare Weight. Enter this number in the space provided.
Tare Weight of Entire Empty Truck
Weigh the entire empty trailer (all axles). This is the trailer’s Tare Weight. Enter this number in the space provided.
Tare Weight of Entire Empty Trailer
_____________
_____________
Stop the empty truck and trailer on level ground.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 4 15
4. With the truck empty, lock the meter on Channel A using the Cycle button. The displayed weight is the Tare Weight. Note: The truck and trailer must not be in a twist or turn.
5.
6.
Press and hold the Tare button to display Tare Reference Number. Use the Up or Down
Arrow buttons to change the value displayed, so when the Tare button is released, it matches the Empty Truck weight. Note: When Tare button is held down the number displayed is not the Tare Weight.
Lock the meter on Channel B using the Cycle button. The displayed weight is the Tare
Weight.
7. Press and hold the Tare button to display Tare Reference Number. Use the Up or Down
Arrow buttons to change the value displayed, so when the Tare button is released it matches the Empty Trailer Weight. Note: When Tare button is held down the number displayed is not the Tare Weight.
8
.
IMPORTANT:
Leave the meter on for a minimum of 3 minutes after changing the Tare
Weight so the new values will be recorded into permanent memory. Starting the truck, turning the ignition switch during this time will cause the meter to reset and return to a previous
setting.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
16 CHAPTER 4
4.3 CALIBRATION PROCEDURE FOR GROSS
VEHICLE WEIGHT METHODS
4.
3.
1.
2.
Fully load the truck close to the legal limit.
Weigh the loaded truck and then the loaded trailer using same certified scale, write them here: a) Channel A Loaded Weight: b) Channel B Loaded Weight:
Park on level ground.
(Loaded truck)
(Loaded trailer)
Lock meter on Channel A using the Cycle button to display weight. If displayed weight does not match** Channel A Loaded Weight in Step 2, correct as follows: a) Press and hold Cal button down to display Cal Number.
5.
displayed Cal button is released matches Channel A loaded truck weight
above.
Lock meter on Channel B using the Cycle button to display weight. If displayed weight does not match** Channel B Loaded Weight in Step 2, correct as follows: a) Press and hold Cal button down to display Cal Number.
displayed Cal button is released matches Channel B loaded truck weight
above.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 4 17
Figure 4-A: Truck Gross Weight (Channel A) in Relation to a Certified Platform Scale
** With in 1% of gross vehicle weight. It is common for operators to calibrate better than 1%.
If additional assistance is needed to fine tune your scale system, please follow the instructions shown in Section 7.3 “Fine Tuning Your Scale System”.
4.4 VERIFYING TARE WEIGHTS
3.
2. Park on level ground.
Lock meter on Channel A using the Cycle button to display Tare Weight.
If displayed Tare Weight matches (+/- 400 lb) Channel A Tare Weight originally set into meter, you have successfully calibrated this channel. Go to Step 4.
If displayed Tare Weight does not match (+/- 400 lb) Channel A Tare Weight originally set into meter, continue to fine tune the calibration by repeating the process beginning at Section
4.3.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
18 CHAPTER 4
4. Lock meter on Channel B using the Cycle button to display Tare Weight.
If displayed Tare Weight matches (+/- 400 lb) Channel B Tare Weight originally set into meter, you have successfully calibrated this channel.
If displayed Tare Weight does not match (+/- 100 lb) Channel B Tare Weight originally set into meter, continue to fine tune the calibration by repeating the process beginning at section
4.3.
5.
IMPORTANT:
Leave the meter on for a minimum of 3 minutes after changing the Tare or Cal Numbers so the new values will be recorded into permanent memory. Starting the truck, turning the ignition switch during this time will cause the meter to reset and return to a
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 4
4.5 KEEPING
1.
2.
3.
4.
5.
Lock meter on Channel A using Cycle button.
Read displayed Tare Weight shown on meter display, write below.
Press and hold the Cal button to display Cal Number, write below.
Lock meter on Channel B using the Cycle button.
Read displayed Tare Weight shown on meter display, write below.
6. Press and hold Cal button to display Cal Number, write below.
CALIBRATION NUMBERS - QUICK REFERENCE
Channel A Tare Number:
Final Channel A Cal Number:
Channel B Tare Number:
Final Channel B Cal Number:
Most Important:
• Adjust the Tare Number only when empty.
• Adjust the Cal Number only when loaded.
19
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
20 CHAPTER 4
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 5
C H A P T E R 5 . 0
MAINTENANCE
2.
1.
In order to keep any system functioning properly, it is important that the system be properly maintained. This includes daily vehicle inspections and preventive maintenance.
5.1 DRIVER’S DAILY VEHICLE INSPECTION
Check load cells, mounting brackets, and fasteners. Make sure they are secure.
If torque stripes have been applied, make sure they are properly aligned. To apply a torque stripe: Use a durable, brightly colored paint. Paint a stripe crossing the head of the fastener, continuing down the fastened structure, as shown.
21
Figure 5-A: Painting a Torque Stripe
3. Check and remove any build up of mud, ice, or other debris that may obstruct the load cell load path. Refer to the drawing below and Section A in Figures 5-C through 5-F.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
22 CHAPTER 5
Figure 5-B: Load Path Diagram
4. Check the meter mounting and wiring, make sure they are secure.
5. Check the green plug attached to the back of the meter. Make sure it is secure.
6. Check the system. Make sure the meter powers up after it has been turned on, digits are legible, and the system functions normally.
7. Check all wiring for condition (no cracks or splits), security, chaffing, and protection from
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 5 23
5.2 PREVENTIVE MAINTENANCE AND VULCAN
TORQUE
The following simple, but important, preventive maintenance steps must be performed periodically
2. after 500 miles, monthly afterwards, or more frequently, if needed.
1. Look for mud, ice buildup, or other debris between the load cell and bracket. Refer to
location A shown on Figures 5-C through 5-F.
Check load cell connectors (refer to location B shown on Figures 5-C through 5-F ), make sure they are finger tight plus an additional 1/8 of a turn with channel lock pliers. The additional tightening is necessary to prevent scale errors, which can occur from moisture entering into the load cell connector. Do not grease or lubricate inside the Vulcan load cell connector or Vulcoder connector. These components are highly sensitive to foreign substances and inaccurate readings will occur if these components are contaminated. Your
manufacturer’s warranty does not cover the failure of Vulcan components due to contamination (use of grease or other conductive substance) in either the Vulcan load
cell connectors or Vulcoder connectors. If a connector is opened for any reason, you must clean the load cell connector and cable connector with cotton swabs and isopropyl alcohol, dry with a hair dryer (DO NOT OVERHEAT), and replace the O-ring before
reconnecting.
3. Check the torque on load cell cap screws monthly. New trucks must be checked once a week for 2 weeks. Vulcan On-Board Scales recommended torque values are shown on Figures 5-C through 5-F and general torque values shown below. As a method of monitoring changes in fastener torque, Vulcan On-Board Scales recommends applying torque stripes to all fasteners
(see Section 5.1, step 2). lb-ft
5/8" 3/4" 7/8" 1-1/8"
210-240 400-500 400-590 650-890 1000-1400
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
6.
24
4.
CHAPTER 5
Vulcan load cells are plated for increased rust protection. Certain minimum maintenance will be necessary to claim warranty of load cells. Annually, apply a high quality paint to the load cells, bearing pads, and mounting brackets. For environments where high concentrations of salts are used on road surfaces, undercoating is recommended (3M, Universal Rubberized Undercoating, 3M P/N: 8883). Spray undercoating when load cells are connected to electronics and fully assembled with bearing pads and brackets. See “Vulcan Load Cell Maintenance” document 44-20006-001 for further details.
5. Fill unused holes in load cells with grease to protect against rust. Never grease the inside of the connector.
Check welds on load cell brackets. IMPORTANT: If a weld repair is required, either
remove the load cell or do not exceed 140 degrees Fahrenheit (60 degrees Celsius) on the load cell. Arcing on the body of the load cell may seriously damage the load cell’s structural integrity and must NOT be installed if this occurs. This also voids the
7. Check all wiring for condition, routing, and protection.
8.
9.
Check meter for secure mounting and strain relief of wires.
Check system for functionality.
10. Review and address any driver concerns.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 5
Typical Western Logger Mounting
25
Figure 5-C
Typical Hutch or Transpro Center Hanger Mounting
January 2004
Figure 5-D
VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
26
Typical Single Point Mounting
CHAPTER 5
Figure 5-E
Typical Holland 5th Wheel Mounting
January 2004
Figure 5-F
VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 5
5.3 METER BUTTON REPLACEMENT AND CLEANING
27
1.
2.
Figure 5-G
5.3.1 DISASSEMBLE PROCEDURE
First remove meter from truck.
Remove defective or dirty button using a small screwdriver. Place the blade under the lip of the button and gently pry up. Note: It is not necessary to disassemble meter to remove buttons.
3. Lift out metal dome switch from switch base as shown in Figure 5-G. Caution: Care must be taken not to drop the switch dome inside the meter. If the switch dome does get inside, it will have to be removed before the meter is plugged into the power source.
4. Clean out any dirt that may be in the switch base. Clean the center contact. This can be done by lightly scraping or by using a pencil eraser.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
28 CHAPTER 5
5.3.2 RE-ASSEMBLE PROCEDURE
2.
1. Place the silver and gold switch dome in the switch base with the gold side towards the meter and the silver raised dome facing out.
Snap the new plastic button into position by using a small screwdriver (place the blade against the lip of the button and gently press in). The taper surface face needs to be installed as shown in Figure 5-G.
3. Re-install the meter, turn it on, an check the function of the buttons.
NOTE: If button starts sticking, disassemble the switch as described. Clean both the center contact in the base and switch dome. Re-assemble.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6
29
C H A P T E R 6 . 0
TROUBLESHOOTING
In general, troubleshooting is a systematic process of testing and eliminating potential problem sources until the one that is causing the problem is found. The problem can then be fixed by repairing or replacing the faulty part.
With a little knowledge, and by following a step by step procedure, most of the problems that you may encounter will be easy to diagnose and cure. In this section, you will find guidelines on how to troubleshoot the system, some characteristics of a properly functioning system, and where to look when certain problems occur.
Occasionally, someone has a problem that is not described here. Do not panic. By approaching the problem systematically, you will be able to eliminate potential sources of trouble until you find the one that is causing the problem.
The following section covers an explanation of Load Cell Evaluation Test Procedures and Vulcan
Error Codes. If a problem occurs and no Error Codes appear, use the V200 Meter to isolate the problem to either Channel A or B.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
30 CHAPTER 6
6.1 VULCAN CHECK-OUT BOX
The Vulcan Check-Out Box works as an extension to bring connector pins to the side of truck where readings can be conveniently made and it can also simulate an applied load to the Vulcoder. The
Check-Out Box is required equipment for the Vulcoder Check-Out Procedure (Section 6.2.4) and is an optional equipment item for the Leakage and Resistance Tests (Section 6.2.1 and 6.2.3).
Before using the Check-Out Box, make sure the meter fuses are good. Use a multi-meter to ensure there is a minimum of 12 Vdc at the back of the meter . (Make sure the green plug is plugged in and the meter is turned on.) If there are any error messages displayed refer to Section 6.3 “V200 Meter
Error Codes”.
Figure 6-A: Vulcan Check-Out Box
To order a Check-Out Box (P/N: 56-10425-001), contact your Vulcan dealer.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6 31
6.2 LOAD CELL EVALUATION TESTS
The tests listed below will help identify and locate any problem you may encounter with your Vulcan
Scale System.
Leakage Test
Tare Test
Resistance Test
Vulcoder Check-Out Test
6.2.1 LEAKAGE TEST PROCEDURE
Required Equipment: Multi-meter
Optional Equipment:
Vulcan Check-Out Box
The Leakage Test Procedure detects the presence of moisture that could cause erratic meter readings.
The way to measure leakage is to use a digital multi-meter that has a conductivity scale. Electrical isolation is measured between any pin and an unpainted clean surface on the load cell or the connector body. Electrical isolation must not exceed 2.0 nS (nano-siemans) or be less than 500 Meg Ohms.
Refer to Figure 6-B for the Leakage Test equipment set-up. If a Vulcan Check-Out Box is used, it is important that the Vulcoder leads from the load cells of the channel being tested are disconnected.
For proper operation, the power and signal leads from the load cell must have a very high resistance to the load cell body. An electrical path between the wires and the body would indicate moisture in the cell or shorting to the body. This would result in erratic, fluctuating, or even out of range weight displays.
If the load cell fails (electrical isolation is greater than 2.0 nS or is less that 500 Meg Ohms), check the inside of the load cell connector with a dry cotton swab to make sure it is clean and dry. If not, clean with isopropyl alcohol, dry with a hair dryer, and check the electrical isolation again.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
32 CHAPTER 6
Caution: Do not touch the probes with your hands when making measurements. This could cause an error in the meter reading. A person’s body can have 10 times the allowable conductivity of a load cell.
OR
Leakage Test Specifications:
Measured between any pin and an unpainted clean surface of the load cell or connector body.
Electrical Isolation should not be greater than 2.0 nS or less than 500 Meg Ohms.
Figure 6-B: Leakage Test
If the load cell cannot be brought to Vulcan specifications, contact your Vulcan dealer.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6
6.2.2 TARE TEST PROCEDURE
Required Equipment: Vulcan V200 Meter
33
O-rings
1.
Channel Lock Pliers
Checks each load cell for a high Preload Number caused by mechanical damage or moisture.
Park the empty truck on level ground.
3. Record the current Tare Weight.
Current Tare Weight ___________
4. Press and hold the Tare button. Use the Up or Down Arrow buttons to change the display to
read zero.
5. Press and hold the Cal button. Write down the current Cal Number.
Current Cal Number __________
Then change the Cal Number using the Up or Down Arrow buttons to display 2050.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
34 CHAPTER 6
7.
8.
6. Clean and re-connect each load cell to the Vulcoder one at a time. The meter will display the load cell Preload Number. The Preload Number should fall between +12,000 to -12,000
counts.
If the Preload Number exceeds +12,000 to -12,000 counts, proceed with steps 6-a to 6-f. a) Clean the load cell connector and cable connector with cotton swabs and isopropyl alcohol. b) Dry thoroughly with a hair dryer. DO NOT OVERHEAT. c) Check the electrical isolation by performing the Leakage Test. (Refer to Section 6.2.1). d) If a Vulcan Check-Out Box is available, perform the Vulcoder Check-Out Test.
(Refer to Section 6.2.4) e) Check the Preload Number again to see if it is within the +12,000 lb to - 12,000 lb range.
If the load cell is still out of range, it may be faulty. Perform the Resistance Test.
(Refer to Section 6.2.3) f) Replace the O-rings before re-connecting.
Measure the Preload Number of the remaining load cells one at a time.
Reset the original Cal Number and Tare Weight.
If the load cell cannot be brought to Vulcan specifications, contact your Vulcan dealer.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6 35
6.2.3 RESISTANCE TEST PROCEDURE
Required Equipment: Multi-meter
Optional Equipment: Vulcan Check-Out Box
Please refer to drawing below in setting up the Resistance Test. The resistance in the pins should correspond to the Vulcan specifications listed below. This test can be conducted with a multi-meter or a Vulcan Check-Out Box. Refer to acceptable resistance ranges as shown below.
OR
Pins
A to D
Figure 6-C Resistance Test
Terminal
Color Code
Red to Black
Acceptable
Resistance Range
349 to 400 Ohms
B to C Green to White 349 to 352 Ohms
Pin B (Green) to Pin A (Red) should be the same number as Pin B (Green) to Pin D (Black) within 1 Ohm.
Pin C (White) to Pin A (Red) should be the same number as Pin C (White) to Pin D (Black) within 1 Ohm.
If the load cell cannot be brought to Vulcan specifications, contact your Vulcan dealer.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
36 CHAPTER 6
6.2.4 VULCODER CHECK-OUT PROCEDURE
Required Equipment: Vulcan V200 Meter
Vulcan Check-Out Box
Using the Cycle button, lock the meter on the Channel that the Vulcoder will be tested on either
Channel A or B. Refer to section 7.2 to identify V200 Vulcoders. Set the Calibration Number to 2050 on the channel being tested (for 2 mV/V Vulcoders, set to 4100, for 3 mV/V Vulcoders, set to 6150).
Set the Tare Reference Number for that channel to zero using the following procedure. Disconnect all load cells from Vulcoder on the channel being tested. While depressing the Tare button, use the Up or Down Arrow buttons to make the display read zero. The display must read zero while the Tare button is depressed. Release the Tare button.
With all load cells disconnected on the channel being tested, plug a Vulcoder lead into the Check-Out
Box (load switch “OFF”). The meter display must read zero (+/- 200 lb). If the Tare Reference
Number is not zeroed, the cabling is damaged. Move the load switch to “ON” indicted by the red dot.
The V200 meter must display 38,200 lb (+/- 200 lb). Check all leads. If any Vulcoder lead does not perform as stated above, the black Vulcoder cable is damaged and must be inspected and repaired. If all Vulcoder leads do not perform as stated above, all have been damaged or the Vulcoder needs to be replaced. Contact your Vulcan dealer for repair or replacement of damaged Vulcoder lead.
6.3 V200 METER ERROR CODES
The V200 Meter is equipped with a self diagnostic program. Should a malfunction occur, the meter will display an error code. This error code can be used to isolate and identify a problem with the
Vulcan Scale System. If an error code is displayed on the screen while the meter is locked on Channel
A+B, use the Cycle button to isolate the problem to either Channel A or Channel B.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6
Listed below are the error code definitions, possible causes, and procedures to correct the system malfunction.
6.3.1 Err 1
Indicates that the Vulcoder is processing an over-ranged signal. An over-ranged signal means that the load cell output is greater than the maximum that the Vulcoder will accept. Err 1 is displayed briefly when the meter is first turned on and clears after the meter and Vulcoder get
in synch.
Possible Causes:
1.
2.
3.
4.
5.
The load cells are being over-loaded.
There is moisture in a load cell connector.
One of the Vulcoder-to-load cell cables has been damaged.
A load cell is faulty.
A load cell has a large Preload Number.
What to Do:
1. Check and verify that the Cal Number is reasonable. Refer to Section 7.1 “Starting
37
2.
3.
Perform Tare Test (refer to Section 6.2.2).
Check the load cells. Check by disconnecting one load cell at a time. When the faulty load cell has been disconnected, the meter will read a number instead of the error code.
4. Check mounting of the load cell per Section 5.2 “Preventative Maintenance and Vulcan
Torque Specifications”, Figures 5-C to 5-F.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
38 CHAPTER 6
6.3.2 Err 2
Indicates that the reading to be displayed is beyond the limitations of the meter’s display.
Possible Causes:
1.
2.
Cal Number set too high.
Tare Weight set too high.
What to Do:
1. Check and reset Cal Numbers and Tare Weight.
6.3.3 Err 3
3.
Indicates that the meter is not receiving a signal from the Vulcoder (or that a very large over
range signal is being sent to the meter).
Possible Causes:
1.
2.
There is usually an open circuit between the meter and Vulcoder. This is the most common reason.
Disconnected or broken green or white Vulcoder wires between the back of the meter and the
Vulcoder.
3.
4.
5.
Faulty Vulcoder or meter.
Faulty load cell.
Moisture in the load cell connectors.
What to Do:
1. Check the wires in the green plug at the back of the meter and ensure that they are firmly in place. Unplug and plug the connector back in the meter to check for proper connection.
2. Check the voltage at the back of the meter and Vulcoder. Make sure the voltages match the required voltages in Section 7.4 “System Specifications”.
Check the orange cable for broken wires.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6 39
4. Check the voltage at the load cell connector. Refer to the required load cell voltages in Section
7.4 “System Specifications”. Repair or replace the Vulcoder as necessary.
5. Disconnect one load cell and then the other to see if this clears the error code. If the error code is cleared, the load cell may be faulty. Conduct all three load cell tests; Leakage, Tare, and
Resistance (refer to Sections 6.2.1 through 6.2.3).
6. Replace the O-rings, clean the connector with isopropyl alcohol, and dry with a hair dryer.
Reconnect the load cells.
6.3.4 Err 4
Same as Err 1.
6.3.5 Err 5
This error code is not used.
6.3.6 Err 6
Indicates a malfunctioning Vulcoder circuit. Err 6 may also appear briefly as an over-ranged signal comes within range.
Possible Causes:
1. Moisture problem at load cell connector.
What To Do:
1. Perform checks on page 38, section 6.4.3.
Note: When both load cells are disconnected from the Vulcoder, the meter does not necessarily display an error message. Often, the meter will display a steady number (e.g. 79100) or it may display a number that jumps around.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
40
6.4.1 No Indicator Display or Functioning Lights
2.
3.
4.
5.
Possible Causes:
1. Power switch turned off.
6.
7.
Power to the meter has been disconnected.
Bad meter cable connections to the battery.
Battery is low (under 11 Volts).
A fuse is blown in the power or ground cable.
Meter’s internal circuit breaker is blown.
Faulty power switch.
CHAPTER 6
2.
3.
What to Do:
1. Check the power to the meter. When the meter is turned on and off, the power must not change more than .5
Vdc. If the meter still does not work, proceed to step 2.
Check the fuses for both negative and positive leads. Use 3 amp fast blow fuses only.
Check that the power supply wires are attached correctly at the 12 Vdc power source and to the green connector at the back of the meter. Check the battery connections for corrosion.
4. If a spare meter is available, the quickest and easiest next step is to change the meter. If the new meter works, try the old meter again. If the old meter now works, the problem was likely the meter’s internal circuit breaker. If both the old meter and the new meter do not work, the problem is most likely in the power source (battery, meter power cable, or fuses). If the new meter works, but the old one does not, the old meter is faulty.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6 41
If you do not have a spare meter, disconnect then reconnect, the green power plug on the back of the meter. If the meter does not work, then check the power source (battery, meter power cable, or fuses). If the power sources check out, then the meter is faulty.
6.4.2 Unable To Enter Tare or Calibration Numbers
Possible Causes:
1. Meter may have dirty button connections.
What to Do:
1. Check to see if any buttons are defective. (You need to be on Channel A or B, but not A + B).
A. Press and hold Tare button to display Tare Reference Number. If it does not, then the
Tare button is faulty. (Refer to the maintenance section 5.3, page 27) button is faulty. Check for a dirty or bad connection. (Refer to the maintenance section 5.3, page 27) the Down button is faulty. Check for a dirty or bad connection. (Refer to the maintenance section 5.3, page 27).
D. Press and hold Cal button to display Cal Number. If it doesn’t then the Cal button is faulty. (Refer to the maintenance section 5.3, page 27)
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
42 CHAPTER 6
6.4.3 Meter Reading Drifts or Wanders With Time
Possible Causes:
1. Voltage to meter or Vulcoder is less than 12.3 Vdc.
2.
3.
4.
Voltage out of the Vulcoder is less than the voltage output required as stated in Section 7.3
“System Specifications.”
Moisture in a load cell connector.
Damaged cable between Vulcoder and load cell.
5. Bad connection on green connector or broken wire or cable between meter and the Vulcoder.
6. Faulty load cell.
What to Do:
1. Using a voltmeter, check the voltage at the back of the meter. Refer to the required meter voltages in Section 7.4 “System Specifications”.
2. Check the black 4-wire cabling between the load cells and the Vulcoder. If the cabling is damaged, contact your Vulcan dealer for Vulcoder repair.
3. Measure the voltage between pins A and D of the Vulcoder connector. If it measures less than
7.5 Vdc (+/- .5 Vdc), make sure the Vulcoder cable is securely attached to the meter green plug and the length of the orange cable from the Vulcoder to the meter is not longer than 100 ft.
Also check any truck / trailer connectors in the Vulcoder signal cable.
4. Before proceeding, clean the load cell connector and cable connector with isopropyl alcohol and cotton swabs, then dry with a hair dryer. Do not overheat. Reconnect and operate system for one day to see if the problem is fixed. If the problem is not fixed, continue to step 5.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6 43
5.
If two load cells are connected per Vulcoder, follow steps, 5a and 5b.
a. Disconnect the cable to the right load cell. Watch the meter display the number for a period of 5 minutes. If it wanders more than 200 lb (100 kg), make a note of it. Then, clean and reconnect the right load cell. b. Disconnect the cable to the left load cell. Watch the meter display the number for period of 5 minutes. If it wanders more than 200 lb (100 kg), make a note of it. Then, clean and reconnect the left load cell.
If any one of the load cells wanders more than 200 lb (100 kg), perform the Leakage and Resistance tests (refer to Sections 6.2.1 and 6.2.3). If both of the load cells wander more than 200 lb (100 kg), then the Vulcoder is faulty and needs to be checked (refer to Section 6.2.4 “Vulcoder Check-Out
Procedure”).
If four load cells are connected per Vulcoder, follow steps, 5c and 5f.
c. For Vulcoders with 4 load cells, disconnect the cables to all the load cells except the right front load cell. Watch the meter display a number for a period of 5 minutes. If it wanders more than 200 lb (100 kg), make a note of it. d. Disconnect right front load cell and reconnect right rear load cell. Watch the meter display for 5 minutes. If it wanders more than 200 lb (100 kg), make a note of it. e. Disconnect the right rear load cell and reconnect the left rear load cell. Watch the meter display for 5 minutes. If it wanders more than 200 lb (100 kg), make a note of it. f. Disconnect the left rear load cell and reconnect the left front load cell. Watch the meter display for 5 minutes. If it wanders more than 200 lb (100 kg), make a note of it.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
44 CHAPTER 6
If any one of the load cells wanders more than 200 lb (100 kg), perform the Leakage and Resistance tests (refer to Sections 6.2.1 and 6.2.3). If all of the load cells wander more than 200 lb (100 kg) then the Vulcoder is faulty and needs to be checked (refer to Section 6.2.4 “Vulcoder Check-Out
Procedure”).
6.4.4 Meter Reading Does Not Change When Truck Is Being Loaded
2.
3.
4.
5.
Possible Causes:
1. Voltage to meter is below 12.3 Vdc.
Mud or ice build-up under the load cells.
Calibration Number on the meter is set too low.
Faulty load cell.
Broken wire or bad connection between the load cell and Vulcoder.
What to Do:
1. Using a voltmeter, check the power at the meter’s green plug at the back of the meter. Refer to Section 7.4 “System Specifications”. If the voltage is below 12 Vdc, the problem could be in the power source (battery, meter power cable, and / or fuses).
2. Reset the meter by unplugging the green connection on the back of the meter for a few seconds.
3. Refer to Section 7.1 “Starting Calibration Numbers”, to verify that the Cal Number is within range.
4. Check the black cables between the load cells and the Vulcoder. If the cabling is damaged the
Vulcoder needs to be repaired or replaced. Contact your Vulcan dealer.
5. Perform the Leakage, Tare, and Resistance Tests (refer to Sections 6.2.1 through 6.2.3).
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6
6.5 TROUBLESHOOTING WORKSHEET
Briefly describe your problem:
Do you have Vulcan electronics? If not, whose?
Do you have all Vulcan load cells?
If not, whose Channel A load cells?
If not, whose Channel B load cells?
HISTORY
Were the scales put on a new vehicle or were they retrofitted?
How long have you had this system?
Has the system ever worked?
How long has the current driver been using the vehicle?
Has there been any mechanical work or maintenance done to the vehicle, changed bridge beam, bunk, etc.?
Has there been any electrical work or maintenance done to the vehicle, battery work, generator / alternator problems, added accessories, jump start?
Has there been any recent maintenance of the scale system, parts exchanged, etc.?
Has anything else happened to the rig such as an accident?
SYMPTOMS
Does the problem occur on Channel A or B, or both?
Does the meter drift up and / or down, fast or slow, or both?
Is the problem intermittent, constant, or both?
Does problem occur on flat road or off-road or both?
January 2004
45
VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
46
Does it occur in wet or dry weather or both?
Does it occur at morning, at night, or both?
Does it occur when empty, loaded, or both?
INSPECTION
Has the same platform scale been used to check scale accuracy?
Is the power cable connected directly to the battery?
Have you checked fuses in both power and ground wires?
Are you using Vulcan yellow fuse holders?
Are you using Vulcan orange cable or trailer light cable?
Is there mud or ice build-up between the load cell pads and vehicle frame?
Is there any contact on top of the load cell mounting cap screw heads?
CHAPTER 6
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 6
6.6 TROUBLESHOOTING ASSISTANCE AND
REPLACEMENT
If you need additional assistance, parts, or service, give us a call at:
47
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 7
C H A P T E R 7 . 0
APPENDIX
48
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 7
7.1 STARTING CALIBRATION NUMBERS
LOAD CELL
VULCODER
15" SUPER-BEAM
15" SUPER-BEAM IN
MODULAR CENTER
HANGER
17" SHEAR BEAM
SINGLE POINT
26" SUPER-BEAM
STOCK
NO.
L01, L02
L01, L02
L03
V01
(1mV/V)
2050/930*
2050/930*
2100/955n/r
V04
(2mV/V)
4100/1860
4100/1860
4200/1910*
V03
(3mV/V)
6150/2790
6150/2790
6300/2865
26" HEAVY DUTY
SUPER-BEAM
19" FIFTH WHEEL
AIR SENSOR
L08, L09,
L18, L19
L11
L04, L05,
L31
L20, L21,
L27
2050/930*
3075/1395n/r
2050/930n/r
6150/2790
4100/1860
6150/2790*
4100/1860*
6150/2790
6150/2790
9225/4185
6150/2790
6150/2790
28" SHEAR-BEAM,
EXTRA HD
4" TRUNNION
LOAD CELL
L32, L33
3650/1660n/r
N/R
7300/3320*
N/R
N/R
N/R
* - Factory recommended Vulcoder for this load cell. n/r- Not recommended for this load cell
NOTES:
1. Final Cal Number should be within +/- 200 counts of Starting Cal Number.
If not, troubleshoot the system for possible mechanical or electrical problem.
2. Vulcoder Stock No. V02, (Designed for 7-Pin Connectors), use Cal Number 6150.
V22
(1mV/V)
2050/930
2050/930
2100/955
2050/930
3075/1395
N/R
61502790*
N/R
8200
49
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
50 CHAPTER 7
7.2 IDENTIFY V200 VULCODERS
The Vulcoder’s Serial number is stamped on the case. Use the serial number to identify its part number. Use the table in Section 7.1 to find the starting calibration number for each channel.
Example: Vulcoder serial number 96451C used with Tandem Center Hanger load cells, in the
“lbs” mode. Vulcoder part number would be V04. Calibration number for that Channel would be 3900.
SERIAL NUMBER
_ _ _ _ _
_ _ _ _ C
_ _ _ _ V
_ _ _ _ A
PART NUMBER
V01
V04
V03 3mv/V
V02
RANGE
1 mv/V
2 mv/V
7 pin (use Cal
Number of 6150/2790).
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 7
7.3 FINE TUNING YOUR SCALE SYSTEM
51
4. flashing.
2. Fine tuning: Complete a row of information each time using the same certified scale. Do this six times filling in rows 1 through 6.
Channel A Cal Number = 2050
Channel B Cal Number = 2050
No. Date Meter
Truck Fully Loaded
Display Platform
Truck Empty
4
5
6
1
2
3
3. When you have entered six certified scale weights, call Vulcan Customer Service at 1-800-
237-0022 to determine your fine tuned Cal numbers. Enter the new Cal numbers in the meter.
Channel A New Cal Number = __________
Channel B New Cal Number = __________
Confirmation: Complete a row of information for six more certified scale weights.
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
52 CHAPTER 7
3
4
5
6
No. Date Meter
Truck Fully Loaded
1
2
Display Platform
Truck Empty
5. Call Vulcan Customer Service again at 1-800-237-0022 to confirm the system calibration.
Final Calibration Channel A Cal Number = __________________
Final Calibration Channel B Cal Number = __________________
Final Calibration Numbers set ___________ (Date)
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
CHAPTER 7
Load Cells
Electrical:
Connector:
Voltage Required:
Material:
Operating Temp:
System Accuracy:
350 Ohms nominal impedance.
4 pin bulkhead, military type.
7.5 +/- .5 Vdc.
High grade alloy steel.
-40 to +140 degrees F.
Typical error less than 1% Full Scale of actual weight for operating temperature range and normal
Vulcoder
Environment: Environmentally sealed electronics.
Operating Temp.:
4-Wire Cable, Black:
-40 to 180 degrees F.
Custom, shielded, 4 conductor, polyurethane jacket with drain wire, 5 ft.
2-Wire Cable, Orange:
Connectors:
Voltage Input Required:
Voltage Output Required:
Signal Input Range:
Meter
Display:
Cycle Speed:
Graduation:
Display Range:
Voltage Required:
Current Draw:
Protection:
Hookup:
Operating Temp:
Weight:
Installation:
Custom polyurethane jacket, 45 ft length.
4 pin, military type.
12.3 to 16.0 Vdc.
7.5 +/- .5 Vdc.
1 to 3 mV/V.
Automatically backlit liquid crystal display.
Variable cycle speed, 1 - 9 seconds.
100 lb increments in lb mode, 50 kg in kg mode.
-99,900 to 320,000 lb or kg.
12.5 to 16.0 Vdc.
150 mA to 350 mA.
Internal, reverse polarity and external, 3 amp quick blow fuses.
Screw type, quick release terminal block on rear panel.
20 to 160 degrees F.
17 oz. (including bracket).
Power cables, fuses, mounting bracket and thumb screws provided.
53
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
54
NOTES
CHAPTER 7
January 2004 VULCAN ON-BOARD SCALES 1-800-237-0022
© STRESS-TEK, INC.
Doc. 44-10015-001 Rev A.
advertisement
Key Features
- Measures gross vehicle weight and net payload weight
- Includes load cells, Vulcoders, and a meter
- Easy to calibrate and maintain
- Displays weight readings in pounds or kilograms
- Can be used on all types of vehicles