Touch to zoom
— + ¢-¢ LOAD CELLS fc ]e-e LOAD CELLS OVERALL Ÿ - Fe Je-e LOAD CELLS + [Fe LOAD CELLS [o)e-e LOAD CELLS - | © | © 1 _ [Hje-e LOAD CELLS Fo]e-e LOAD CELLS —— — — (4) OPTIONAL MANHOLE: | NOTE à E OU TYP = 7 FIRSTS TERM MODULES NN `` TN * cooa I Coo an Coo an COOB an COOC NA COOD (COOF) (COOH) (COOH) (C006) (C006) (COOD) | o | In | In | I | In | I N tE WIDTHS O WIDTHS ТЕ D N 0 | | ) | Te 12° 11’; 9 1/4" | 10’: CENTERED DETAIL C | \ | | \ BOTH ENDS TYP ) | DETAL B— Y STD/HAZ INSTRUMENT IN DETAIL B / 1 HAZ INSTRUMENT CABLING JU CABLING TERMINATION TERMINATION (J-BOX) (J-BOX) LA NEL 8 a HAZ INSTRUMENT CABLING TERMINATION (J-BOX) so г [А FOUNDATION LENGTH [В JoveRALL SCALE LENGTH ID Qu A | E Y ! ! o Si vo И AD NN DETAL, A MODULE COMBINATIONS | DIMENSIONAL CHART - | © E e SCALE FIRST MIDDLE MIDDLE | MIDDLE MIDDLE | TERMINAL | up. ка" [ape ca Co ge | a ‘ps | SIZE | pe DIM REF"E"DIM REF"F"DIM REF"6"DIM REF*H*DIM REF "J" DIM ‚| А FON LENGTH a OVERALL LENGTH 0 E F 6 A J 90° 15° 15° 15° 15° 15° 5 89'-11' 89'-10 89'-3" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2" 95 17.5' 15° 15° 15° 15° 17.5" 94'-11" | 94'-10 94'-3" | 17'-4 1/2" | 14*-10 1/2" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2" | 47'-4 1/0" 100° 7.5" 17.5" 15° 5° | 17.5 17.5' 99'-11' 99'-10 99'-3" | 147'-4 1/2" | 47'-4 1/2" |14'-10 1/2" |14'-10 1/2" | 47'-4 1/2" | 147'-4 1/2" 105 17.5" 17.5' 17.5' 17.5' 17.5' 17.5' 1040-11" 104'-10 104-3" | 47'-4 1/0" | 17'-4 1/2" | 47'-4 1/2" | 47'-4 1/2" | 47'-4 1/2" | 17'-4 1/2" NOTES: CONCRETE NOTES: NOTES FOR HAZARDOUS AREA WIRING: 1. FOUNDATION LENGTH DIMENSION SHOWN IS NOMINAL, ACTUAL TOLERANCE 1. USE 4000 PSI CONCRETE AT 28 DAY AGE. AIR ENTRAINMENT SHALL BE 5%-7%. 1. THE HAZARDOUS AREA WIRING AND LIGHTNING PROTECTION KIT IS IS -0 +1" / MAXIMIUM AGGREGATE SIZE IS 3/4". MAXIMUM SLUMP AS PLACED SHALL BE 4". SPECIFIC FOR THE SUPPLY VOLTAGE AND THE INDICATOR USED. IT MUST BE INCLUDED FOR INTRINSICALLY SAFE COMPLIANCE IN 2. THE MODULE SUFFIX IS USED TO DESIGNATE MODULE ASSEMBLY, HARDWARE 2. CONCRETE SHALL BE DIRECT CHUTE PLACED AND THOROUGHLY CONSOLIDATED HAZARDOUS LOCATIONS. AND WIRING CONFIGURATION. HAZARDOUS CONFIGURATION IN PARENTHESIS USING A SPUD TYPE VIBRATOR. 3. APPLY LOCTITE #242 TO ALL GAP COVER BOLTS 3. USE OF CALCIUM CHLORIDE ADMIXTURE IS NOT PERMITTED. 4. APPLY A 1/4" BEAD OF DIELECTRIC COMPOUND IN THE MALE CONNECTOR OF 4. AFTER FINISHING, A STYRENE BUTADIENE TYPE (30% SOLIDS MIN) CURING POWER CELL BEFORE FINAL CONNECTION. 5. IF DIELECTRIC COMPOUND BECOMES CONTAMINATED, CLEAN CONNECTOR WITH COMPOUND SHALL BE APPLIED. EXAMPLES: SUPER FLOOR COAT OR SUPER PLOICURE BY EUCLID; MASTER SEAL 66 BY MASTER BUILDERS. TB202627 CONNECTOR CLEANER. REAPPLY NEW COMPOUND TO THE CONNECTOR. 5. REFER TO METTLER TOLEDO SPECIFICATION TN201832 FOR FURTHER INFORMATION. > — — — DETAILB —— — — — — 6. ESTIMATED CONCRETE PER MODULE IN CUBIC YARDS. (REF ONLY) 15 X 11=3.8 17'6 X 11'= 4.5 __ EE --— DETAIL C —-—- / Ji 49 С AL A | URSS om \ 1 — 3 PLCS пр SS / \ | э |НА Г = O | O | 1/8" MAX GAP | pm 7 |} № ® № BY К in fh is \ | | \ | SHIM AS REQUIRED THIS PIN CAN BE TURNED TO LEVEL MODULES TO CORRECT MISALIGNMENT 5 PLCS TYP \ — — — DETAIL A 1! O © © В | 1/16" MAX GAP ——— © SHIMS TO BE | | IA u TT Tn INSTALLED BETWEEN WASHER AND ANGLE | ANCHOR BOLT NOT SHOWN FOR CLARITY - “© Y -BASEPLATE 34 | 24 | MZ0909000043 CAPLUG; RED, #16 (FOR SIDE LFTG HOLES) 33 | 12 | MZ0909000031 CAPLUG; RED, #19 (FOR ENOPLATE HOLES) 32 | 3 | TN203217 LUBRICANT, LOADCELL-RECEIVER 31 | 50 | TN203216 ANCHOR BOLT 30 | 1 | TN203056 CONNECTOR DIELECTRIC COMPOUND 29 | 1 | TB202627 CONNECTOR CLEANER 28 | 1 | MZ0602000117 LOCTITE $242 THREADLOCKER 27 | 14 | TA200814 BOTTOM HEX RECEIVER 26 | 14 | TA200764 TOP RECEIVER WITH O-RING 25 | 14 | TA200712-3 RECEIVER SHIM 7 GA (.180) 24 | 28 | TA200712-2 RECEIVER SHIM 16 GA (.062) 23 | 28 | TA200712-1 RECEIVER SHIM 11 GA (.125) 22 | 4 | TA200357-3 SLOTTED SHIM 22 GA (.031) 21 | 4 | TA200357-2 | SLOTTED SHIM 16 GA (.062) | 20 | 4 | TA200357-1 SLOTTED SHIM 11 GA (.125) 19 | 4 | TA200864-2 COUPLER SHIM 16 GA (.062) 18 | 4 | TA200864-1 COUPLER SHIM 11 GA (.125) 17 | à | TA200856-3 END BUMPER SHIM 16 GA (.062) 16 | 2 | TA200856-2 END BUMPER SHIM 11 GA (.125) 15 | 3 | TA200856-1 END BUMPER SHIM 1/4" [ITEM |GTY | PART NUMBER | DESCRIPTION HARDWARE KIT OF PARTS: TC204636-1 IMPORTANT: THE INTERIOR SURFACE OF ALL LOAD CELL RECEIVERS (BOTH TOP AND BOTTOM) MUST BE GREASED WITH TN203217 DURING CELL INSTALLATION. -- | 4 | TC204636-1 HARDWARE KIT OF PARTS 13 | 4 | TN204138 STANDARD TOUCH-UP PAINT — TN204213 PREMIUM TOUCH-UP PAINT 19 | 4 | REF СООО SUFFIX | STANDARD WIRING TERMINAL MODULE REF COOD SUFFIX | HAZARDOUS WIRING TERMINAL MODULE ‚| , | REF COOC SUFFIX | STANDARD WIRING TERMINAL MODULE REF COOG SUFFIX | HAZARDOUS WIRING TERMINAL MODULE 19 | + | REF СООВ SUFFIX | STANDARD WIRING MIDDLE MODULE REF C00G SUFFIX | HAZARDOUS WIRING MIDDLE MODULE a | » | REF COOB SUFFIX | STANDARD WIRING MIDDLE MODULE REF COOH SUFFIX | HAZARDOUS WIRING MIDDLE MODULE oo NOTE > | e | 1 | PEF CODA SUFFIX | STANDARD WIRING FIRST MODULE A ' REF COOF SUFFIX | HAZARDOUS WIRING FIRST MODULE 7 | 44 | *14002500A MODEL 760 POWERCELL 22.5t CAPACITY © x15476400A MTX LOAD CELL 25mt CAPACITY 5 | 4 | TN203173 TN203173 GASKET (WITH 760 POWERCELL) / TN203705 TN203705 BOOT (WITH MTX LOAD CELL) IA 5 | 14 | MZ0304000063 |@ 1/2 ROLL PIN, 1 1/2 LONG ==! 4 | 2 | TB200929-4 BUMPER BASEPLATE AIGHT 3 | 2 | TB200929-3 BUMPER BASEPLATE LEFT 2 | 10 | TB200929-2 BASEPLATE SECTIÓN D-D ı | 1 | MN31004 | DATA PLATE BY METTLER TOLEDO: DRILL TWO #29 HOLES IN SUPPORT TUBE AND FASTEN DATA PLATE WITH 1/8" IITEM|QTY | PART NUMBER | DESCRIPTION ALUMINUM AB4-4 POP RIVETS (MZ0904000031) DETAIL MAJOR BILL OF MATERIAL x LETTER PREFIX SUBJECT TO CHANGE REV CHANGE BY DATE SCALE 25 ITEM 13 P/N WAS TN204241 FOR STANDARD PAINT HBW | 01/03/01 DATE 07/10/00 RN ELD | arr 7 A 1 METTLER TOLEDO TITLE 7560 C/D GENERAL LAYOUT 6 MODULE SCALE FRACTIONAL * 1/32 XX *.02 #,5° 1C204636 | ‚XXX £.005 | E UNLESS OTHERWISE SPECIFIED. ALL THIS PRINT IS FURNISHED WITH THE UNDERSTANDING THAT THE ESSENCE THEREOF WILL NOT BE REPRODUCED IN WHOLE DIMENSIONS ARE IN INCHES, AND OR IN PART WITHOUT WRITTEN AUTHORIZATION OF METTLER- DIMENSIONAL TOLERANCES ARE: TOLEDO, INC. ALL DESIGNS ARE THE PROPERTY OF METTLER- DECIMAL ANGULAR TOLEDO, INC. AND WILL BE PROTECTED BY PATENTS. REV A
advertisement