Mettler Toledo 7560 Layout, Six Modules Installation Instruction

Mettler Toledo 7560 Layout, Six Modules Installation Instruction

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Mettler Toledo 7560 Layout, Six Modules Installation Instruction | Manualzz
 —
+
¢-¢ LOAD CELLS
fc ]e-e LOAD CELLS OVERALL
Ÿ
- Fe Je-e LOAD CELLS + [Fe LOAD CELLS [o)e-e LOAD CELLS -
| © | © 1 _
[Hje-e LOAD CELLS
Fo]e-e LOAD CELLS —— —
— (4)
OPTIONAL MANHOLE:
|
NOTE à E OU TYP = 7 FIRSTS TERM MODULES
NN `` TN
* cooa I Coo an Coo an COOB an COOC NA COOD
(COOF) (COOH) (COOH) (C006) (C006) (COOD)
| o | In | In | I | In | I N tE WIDTHS O WIDTHS
ТЕ D N 0 | | ) | Te 12°
11’; 9 1/4" |
10’: CENTERED DETAIL C
| \ | | \ BOTH ENDS TYP
) |
DETAL B— Y STD/HAZ INSTRUMENT IN DETAIL B / 1 HAZ INSTRUMENT CABLING JU
CABLING TERMINATION
TERMINATION (J-BOX)
(J-BOX)
LA
NEL 8 a
HAZ INSTRUMENT CABLING
TERMINATION (J-BOX)
so г [А FOUNDATION LENGTH
[В JoveRALL SCALE LENGTH
ID
Qu A
|
E
Y
! !
o
Si
vo
И
AD
NN DETAL, A
MODULE COMBINATIONS |
DIMENSIONAL CHART
- |
© E
e
SCALE FIRST MIDDLE MIDDLE | MIDDLE MIDDLE | TERMINAL | up. ка" [ape ca Co ge | a ‘ps
| SIZE | pe DIM REF"E"DIM REF"F"DIM REF"6"DIM REF*H*DIM REF "J" DIM ‚| А FON LENGTH a OVERALL LENGTH 0 E F 6 A J
90° 15° 15° 15° 15° 15° 5 89'-11' 89'-10 89'-3" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2"
95 17.5' 15° 15° 15° 15° 17.5" 94'-11" | 94'-10 94'-3" | 17'-4 1/2" | 14*-10 1/2" |14'-10 1/2" |14'-10 1/2" |14'-10 1/2" | 47'-4 1/0"
100° 7.5" 17.5" 15° 5° | 17.5 17.5' 99'-11' 99'-10 99'-3" | 147'-4 1/2" | 47'-4 1/2" |14'-10 1/2" |14'-10 1/2" | 47'-4 1/2" | 147'-4 1/2"
105 17.5" 17.5' 17.5' 17.5' 17.5' 17.5' 1040-11" 104'-10 104-3" | 47'-4 1/0" | 17'-4 1/2" | 47'-4 1/2" | 47'-4 1/2" | 47'-4 1/2" | 17'-4 1/2"
NOTES: CONCRETE NOTES: NOTES FOR HAZARDOUS AREA WIRING:
1. FOUNDATION LENGTH DIMENSION SHOWN IS NOMINAL, ACTUAL TOLERANCE 1. USE 4000 PSI CONCRETE AT 28 DAY AGE. AIR ENTRAINMENT SHALL BE 5%-7%. 1. THE HAZARDOUS AREA WIRING AND LIGHTNING PROTECTION KIT IS
IS -0 +1" / MAXIMIUM AGGREGATE SIZE IS 3/4". MAXIMUM SLUMP AS PLACED SHALL BE 4". SPECIFIC FOR THE SUPPLY VOLTAGE AND THE INDICATOR USED.
IT MUST BE INCLUDED FOR INTRINSICALLY SAFE COMPLIANCE IN
2. THE MODULE SUFFIX IS USED TO DESIGNATE MODULE ASSEMBLY, HARDWARE 2. CONCRETE SHALL BE DIRECT CHUTE PLACED AND THOROUGHLY CONSOLIDATED HAZARDOUS LOCATIONS.
AND WIRING CONFIGURATION. HAZARDOUS CONFIGURATION IN PARENTHESIS USING A SPUD TYPE VIBRATOR.
3. APPLY LOCTITE #242 TO ALL GAP COVER BOLTS 3. USE OF CALCIUM CHLORIDE ADMIXTURE IS NOT PERMITTED.
4. APPLY A 1/4" BEAD OF DIELECTRIC COMPOUND IN THE MALE CONNECTOR OF 4. AFTER FINISHING, A STYRENE BUTADIENE TYPE (30% SOLIDS MIN) CURING
POWER CELL BEFORE FINAL CONNECTION.
5. IF DIELECTRIC COMPOUND BECOMES CONTAMINATED, CLEAN CONNECTOR WITH
COMPOUND SHALL BE APPLIED. EXAMPLES: SUPER FLOOR COAT OR SUPER
PLOICURE BY EUCLID; MASTER SEAL 66 BY MASTER BUILDERS.
TB202627 CONNECTOR CLEANER. REAPPLY NEW COMPOUND TO THE CONNECTOR. 5. REFER TO METTLER TOLEDO SPECIFICATION TN201832 FOR FURTHER INFORMATION.
>
— — — DETAILB —— — — — —
6. ESTIMATED CONCRETE PER MODULE IN CUBIC YARDS. (REF ONLY)
15 X 11=3.8 17'6 X 11'= 4.5
__ EE
--— DETAIL C —-—-
/
Ji 49 С AL A | URSS
om \ 1
—
3 PLCS пр SS
/ \
|
э |НА Г =
O | O | 1/8" MAX GAP
| pm
7 |}
№ ® № BY
К
in fh is
\ | | \ |
SHIM AS REQUIRED THIS PIN CAN BE TURNED
TO LEVEL MODULES
TO CORRECT MISALIGNMENT
5 PLCS TYP \
— — — DETAIL A
1!
O
©
©
В
|
1/16" MAX GAP ———
©
SHIMS TO BE
|
|
IA
u
TT Tn
INSTALLED BETWEEN
WASHER AND ANGLE
|
ANCHOR BOLT NOT
SHOWN FOR CLARITY -
“©
Y
-BASEPLATE
34 | 24 | MZ0909000043 CAPLUG; RED, #16 (FOR SIDE LFTG HOLES)
33 | 12 | MZ0909000031 CAPLUG; RED, #19 (FOR ENOPLATE HOLES)
32 | 3 | TN203217 LUBRICANT, LOADCELL-RECEIVER
31 | 50 | TN203216 ANCHOR BOLT
30 | 1 | TN203056 CONNECTOR DIELECTRIC COMPOUND
29 | 1 | TB202627 CONNECTOR CLEANER
28 | 1 | MZ0602000117 LOCTITE $242 THREADLOCKER
27 | 14 | TA200814 BOTTOM HEX RECEIVER
26 | 14 | TA200764 TOP RECEIVER WITH O-RING
25 | 14 | TA200712-3 RECEIVER SHIM 7 GA (.180)
24 | 28 | TA200712-2 RECEIVER SHIM 16 GA (.062)
23 | 28 | TA200712-1 RECEIVER SHIM 11 GA (.125)
22 | 4 | TA200357-3 SLOTTED SHIM 22 GA (.031)
21 | 4 | TA200357-2 | SLOTTED SHIM 16 GA (.062)
| 20 | 4 | TA200357-1 SLOTTED SHIM 11 GA (.125)
19 | 4 | TA200864-2 COUPLER SHIM 16 GA (.062)
18 | 4 | TA200864-1 COUPLER SHIM 11 GA (.125)
17 | à | TA200856-3 END BUMPER SHIM 16 GA (.062)
16 | 2 | TA200856-2 END BUMPER SHIM 11 GA (.125)
15 | 3 | TA200856-1 END BUMPER SHIM 1/4"
[ITEM |GTY | PART NUMBER | DESCRIPTION
HARDWARE KIT OF PARTS: TC204636-1
IMPORTANT:
THE INTERIOR SURFACE OF ALL LOAD CELL
RECEIVERS (BOTH TOP AND BOTTOM) MUST BE
GREASED WITH TN203217 DURING CELL
INSTALLATION.
-- | 4 | TC204636-1 HARDWARE KIT OF PARTS
13 | 4 | TN204138 STANDARD TOUCH-UP PAINT
— TN204213 PREMIUM TOUCH-UP PAINT
19 | 4 | REF СООО SUFFIX | STANDARD WIRING TERMINAL MODULE
REF COOD SUFFIX | HAZARDOUS WIRING TERMINAL MODULE
‚| , | REF COOC SUFFIX | STANDARD WIRING TERMINAL MODULE
REF COOG SUFFIX | HAZARDOUS WIRING TERMINAL MODULE
19 | + | REF СООВ SUFFIX | STANDARD WIRING MIDDLE MODULE
REF C00G SUFFIX | HAZARDOUS WIRING MIDDLE MODULE
a | » | REF COOB SUFFIX | STANDARD WIRING MIDDLE MODULE
REF COOH SUFFIX | HAZARDOUS WIRING MIDDLE MODULE
oo NOTE > | e | 1 | PEF CODA SUFFIX | STANDARD WIRING FIRST MODULE
A ' REF COOF SUFFIX | HAZARDOUS WIRING FIRST MODULE
7 | 44 | *14002500A MODEL 760 POWERCELL 22.5t CAPACITY
© x15476400A MTX LOAD CELL 25mt CAPACITY
5 | 4 | TN203173 TN203173 GASKET (WITH 760 POWERCELL)
/ TN203705 TN203705 BOOT (WITH MTX LOAD CELL)
IA 5 | 14 | MZ0304000063 |@ 1/2 ROLL PIN, 1 1/2 LONG
==!
4 | 2 | TB200929-4 BUMPER BASEPLATE AIGHT
3 | 2 | TB200929-3 BUMPER BASEPLATE LEFT
2 | 10 | TB200929-2 BASEPLATE
SECTIÓN D-D ı | 1 | MN31004 | DATA PLATE
BY METTLER TOLEDO:
DRILL TWO #29 HOLES IN
SUPPORT TUBE AND FASTEN DATA PLATE WITH 1/8"
IITEM|QTY | PART NUMBER | DESCRIPTION
ALUMINUM AB4-4 POP RIVETS (MZ0904000031)
DETAIL
MAJOR BILL OF MATERIAL
x LETTER PREFIX SUBJECT TO CHANGE
REV
CHANGE
BY
DATE SCALE
25
ITEM 13 P/N WAS TN204241 FOR STANDARD PAINT
HBW | 01/03/01
DATE 07/10/00
RN ELD | arr 7
A
1 METTLER TOLEDO
TITLE 7560 C/D GENERAL LAYOUT
6 MODULE SCALE
FRACTIONAL
* 1/32
XX *.02 #,5° 1C204636 |
‚XXX £.005
| E UNLESS OTHERWISE SPECIFIED. ALL THIS PRINT IS FURNISHED WITH THE UNDERSTANDING THAT
THE ESSENCE THEREOF WILL NOT BE REPRODUCED IN WHOLE
DIMENSIONS ARE IN INCHES, AND OR IN PART WITHOUT WRITTEN AUTHORIZATION OF METTLER-
DIMENSIONAL TOLERANCES ARE: TOLEDO, INC. ALL DESIGNS ARE THE PROPERTY OF METTLER-
DECIMAL ANGULAR
TOLEDO, INC. AND WILL BE PROTECTED BY PATENTS.
REV
A

advertisement