Intermatic PB300E PB313EK, PB314EK electrical timers INSTALLATION OPERATION & SERVICE MANUAL

Intermatic PB300E PB313EK, PB314EK electrical timers INSTALLATION OPERATION & SERVICE MANUAL

Below you will find brief information for electrical timers PB300E PB313EK, electrical timers PB300E PB314EK. This manual provides information on the installation, operation, and service of the PB300E Series electronic timer replacement/upgrade kit. The kit includes all the necessary hardware for a speedy repair or exchange. The PB300E Series timers are designed to fit and replace most PB series Intermatic and certain other brand mechanical or electronic timers. Make sure that the clock supply voltage of the timer slated for replacement is the same as this timer, and the intended load is within the capacity of this timer. The timer is completely enclosed and a replaceable lithium battery will hold up memory for up to three years.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Intermatic PB300E PB313EK, PB314EK Installation Manual | Manualzz

PB300E SERIES

TIME CONTROLS

INSTALLATION

OPERATION &

SERVICE MANUAL

24 Hr. Electronic Timer Replacement/Upgrade Kits

Model: PB313EK; Clock Supply Voltage: 120 V. 50-60 HZ

Model: PB314EK; Clock Supply Voltage: 240 V. 50-60 HZ

GENERAL INFORMATION

The PB300EK Series Electronic Timers are made to fit and replace most PB series Intermatic and certain other brand mechanical or electronic timers. The connected load however, must not exceed the rating of this timer. The timer is completely enclosed and a replaceable lithium battery will hold up memory for up to three years.

The kit contains all the necessary hardware for a speedy repair or exchange.

SPECIFICATIONS

Rating:

16A-Resistive, 8A FLA

Contact Configuration:

Single Pole, Double Pole

Power Consumption:

8V A

Battery Type:

CR2032 (1.5V Lithium)

Battery Life:

3 Years Minimum

No. of Programming Periods:

8 On/8 Off

Minimum Interval:

1 minute

MYLAR INSULATOR

PROTECTING BATTERY

CONTACTS-REMOVE

BEFORE INSTALLATION

NC

NO C

.250 MALE QUICK CONNECT

TERMINALS.

INSTALLATION

CAUTION:

• Make sure the clock supply voltage of the timer slated for replacement is the same as this timer.

• Make sure the intended load is within the capacity of this timer-see specifications above.

INDEPENDENT

CLOCK SUPPLY leads connected to these terminals.

2A. Old Timer with four 1/4 inch tabs: Remove female terminals from tabs and remove timer. Install new timer, using the screws and nuts supplied. Reconnect the two clock supply leads to CLOCK SUPPLY terminals and either one of the load leads to terminal C and the other load lead to N.O. (normally open) terminal.

2B. Old Timer with two CLOCK SUPPLY LEADS and two 1/4 inch LOAD tabs: Disconnect leads at twist on wire connectors and remove female terminals from tabs. Remove timer. Install new timer, using the screws and nuts supplied. Connect the stripped ends of either leads (supplied) to either wire-nutted junctions. Connect either one of the load leads to terminal C and the other load lead to N.O. (normally open) terminal.

2C. For other than Intermatic made timers, timers with 5 tabs and/or permanently attached leads, identify first each lead

or tab then follow 2A or 2B above and corresponding markings on back of new timer.

SETTING / OPERATING INSTRUCTIONS

Programming Instructions

To Set or Change the Time of Day: To clear entire memory, press key. Hold down the CLOCK key while pressing either the HOUR or MINUTE keys.

Continue pressing until the desired number is shown.

Then simply lift finger off the CLOCK key to set.

To Set Program (ON/OFF times): Press TIMER key once to enter into program mode. Display will show

“1 ON-- --”. Press the HOUR key and then the

MINUTE key to select the desired first ON time. Press

TIMER key once. Display will show “1 OFF -- --”.

Repeat previous step to select the desired first OFF time. Repeat the entire sequence to complete up to eight total ON/OFF times as desired. When programming is done, press the CLOCK key then the SELECT key repeatedly until the indicator bar is above the word

“AUTO”.

To Review Program: Press TIMER key repeatedly.

When done, press CLOCK key to return to the time of day.

To Cancel/Change Part of the Program: Press

TIMER key repeatedly until the particular ON or OFF

Programs).

To Override the Automatic Operation one time:

Display

Reset port to cancel all prior settings

Indicator LED “ON” when connected to power source and contacts are closed

ON/AUTO/OFF

Select Key

Function Keys

.

NOTE: Timer will resume automatic operation with the next opposite setpoint.

To Override Automatic Operation Permanently:

Press SELECT key to move indicator bar to the desired

ON or OFF position. Note: Timer will not resume automatic operation until indicator bar is repositioned above the word AUTO.

TROUBLESHOOTING

Symptom

Blank Display

Possible Cause(s) Corrective Action

Defective timer .....................................Replace timer

Memory is full ......................................Press to clear memory

Timer is ON at all times

ONE YEAR LIMITED WARRANTY

If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, the unit free of charge. This warranty applies only to the original purchaser and is not transferable. This warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping, acts of God, or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty gives you specific legal rights and you may have other rights that vary from state to state.

INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR

IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR

PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY

PERIOD STATED ABOVE.

This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing postage prepaid to the nearest authorized service center listed. Please be sure to wrap the product securely when mailing to avoid shipping damage. This warranty is made by:

Intermatic Incorporated/After Sales Service, 7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-7000 http://www/intermatic.com

Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.

INTERMATIC INCORPORATED, SPRING GROVE, IL 60081-9698

158PB12524 http://www.intermatic.com

advertisement

Key Features

  • Replace most PB series Intermatic and certain other brand mechanical or electronic timers
  • Completely enclosed
  • Replaceable lithium battery
  • Up to three years battery life
  • 8 On/Off programming periods
  • Minimum interval of 1 minute
  • Single Pole, Double Pole contact configuration
  • 16A resistive, 8A FLA rating
  • Easy to install
  • Easy to program

Frequently Answers and Questions

What is the clock supply voltage of the PB313EK model?
The clock supply voltage for the PB313EK model is 120V, 50-60 Hz.
What is the clock supply voltage of the PB314EK model?
The clock supply voltage for the PB314EK model is 240V, 50-60 Hz.
How long will the battery last in the PB300E Series timer?
The battery in the PB300E Series timer has a minimum life of 3 years.

Related manuals

Download PDF

advertisement