Danfoss BB440CS Solenoid coil, Type BB, BN, BF, BQ and BY Installation Guide

Danfoss BB440CS Solenoid coil, Type BB, BN, BF, BQ and BY Installation Guide | Manualzz
Installation guide
IP65/PD3
Cable plug
2
IP67/PD4
Terminal box
3
IP67/PD4
Moulded cable
4AB
5D
Danfoss
32U1774.10
1
D
Click ON
!
55mm
mm(2.16 in)
rr>>55
Danfoss
18F58
Danfoss
18F111
IP00/PD3
Spade
018R9670
C
Danfoss
18F61
B
Danfoss
18F60
A
Danfoss
18F9025
018R9670
Solenoid coil
Type BB, BN, BF, BQ and BY
OFF
Type of control
Safety classification
Ambient temperature
Voltage variation
Voltage tolerances
1
Class I
See Tambient on coil
For voltage variation, see print on coil
For voltage tolerances see datasheet, when ordering the coil
Only none-conductive pollution occurs except that occasionally a temporary conductivity caused by
Humidity
condensation is to be expected
Ball pressure test
200 °C (392 °F) in accordance to IEC 60695-10-2
Terminal box
4.0 kV at altitude <4000 m (13123 ft)
Cable
4.0 kV at altitude <4000 m (13123 ft)
Impulse withstand voltage
Spade
4.0 kV at altitude <4000 m (13123 ft)
Plug
4.0 kV at altitude <2000 m (6561 ft)
Plug
3.1 kV 2000 m<altitude<4000 m (6561<altitude<13123 ft)
III
Overvoltage category
Degree of protection IPxx
Enclosure rating according to IEC standard 60529 (See illustration for details A-D)
Pollution degree PDX
Pollution degree according to EN60664-1 (See illustration for details A-D)
Integrated control
Installation
Incorporated control
Independently mounted control (IP65 and IP67)
Suitable cable, Conductor size ø6.6 − ø11 mm (ø0.26 − ø0.43 in)
for plug andterminal box
0.75 − 1.5 mm² (21 − 15 AWG flexible cord)
Suitable cable for cable plug
See datasheet when ordering the coil
Moulded cable size
Ø6.6 mm (ø0.26 in )
Cable conductor size
3 x 0.75 mm² (3 x 0.001 in2)
The supply cord of this control cannot be replaced, if the cord is damaged. The control should be
Moulded cable
discarded
Plugs can be removed/mounted 10 times
Independently mounted controls must be inaccessible in normal use if the surface temperature on the
Surface temperature
control > 85 °C
- Only qualified personnel is allowed to install or maintain this product
- Disconnect the power when dismounting the coil
- Avoid direct exposure to alkaline conditions, use in neutral conditions is recommended
- Ensure that the O-ring is in place on the valve
- If the coil is used as independently mounted control, the end-user shall use a plastic cable gland with strain relief
© Danfoss | DCS (az) | 2018.11
IC.PI.200.&2.02 | 1
7B
6B
Danfoss
18F60
B
8B
40 - 50 Ncm
(0.30 − 0.39 lb-ft)
9B
10B
90°
90°
250 - 375 Ncm
(1.85 − 2.77 lb-ft)
C
50 - 60 Ncm
(0.39 − 0.44 lb-ft)
7C
6C
Danfoss
18F61
OFF
8C
40 - 50 Ncm
(0.30 − 0.39 lb-ft)
9C
80 - 90 Ncm
(0.59 − 0.66 lb-ft)
10C
320 - 370 Ncm
(2.36 − 2.73 lb-ft)
Visit www.products.danfoss.com for further technical data
Para más información, visite www.products.danfoss.es
Rendez-vous sur le site www.products.danfoss.fr pour plus de données techniques
© Danfoss | DCS (az) | 2018.11
IC.PI.200.&2.02 | 2
Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Download PDF

advertisement