Danfoss BB440CS Solenoid coil, Type BB, BN, BF, BQ and BY Installation Guide

Installation guide IP65/PD3 Cable plug 2 IP67/PD4 Terminal box 3 IP67/PD4 Moulded cable 4AB 5D Danfoss 32U1774.10 1 D Click ON ! 55mm mm(2.16 in) rr>>55 Danfoss 18F58 Danfoss 18F111 IP00/PD3 Spade 018R9670 C Danfoss 18F61 B Danfoss 18F60 A Danfoss 18F9025 018R9670 Solenoid coil Type BB, BN, BF, BQ and BY OFF Type of control Safety classification Ambient temperature Voltage variation Voltage tolerances 1 Class I See Tambient on coil For voltage variation, see print on coil For voltage tolerances see datasheet, when ordering the coil Only none-conductive pollution occurs except that occasionally a temporary conductivity caused by Humidity condensation is to be expected Ball pressure test 200 °C (392 °F) in accordance to IEC 60695-10-2 Terminal box 4.0 kV at altitude <4000 m (13123 ft) Cable 4.0 kV at altitude <4000 m (13123 ft) Impulse withstand voltage Spade 4.0 kV at altitude <4000 m (13123 ft) Plug 4.0 kV at altitude <2000 m (6561 ft) Plug 3.1 kV 2000 m<altitude<4000 m (6561<altitude<13123 ft) III Overvoltage category Degree of protection IPxx Enclosure rating according to IEC standard 60529 (See illustration for details A-D) Pollution degree PDX Pollution degree according to EN60664-1 (See illustration for details A-D) Integrated control Installation Incorporated control Independently mounted control (IP65 and IP67) Suitable cable, Conductor size ø6.6 − ø11 mm (ø0.26 − ø0.43 in) for plug andterminal box 0.75 − 1.5 mm² (21 − 15 AWG flexible cord) Suitable cable for cable plug See datasheet when ordering the coil Moulded cable size Ø6.6 mm (ø0.26 in ) Cable conductor size 3 x 0.75 mm² (3 x 0.001 in2) The supply cord of this control cannot be replaced, if the cord is damaged. The control should be Moulded cable discarded Plugs can be removed/mounted 10 times Independently mounted controls must be inaccessible in normal use if the surface temperature on the Surface temperature control > 85 °C - Only qualified personnel is allowed to install or maintain this product - Disconnect the power when dismounting the coil - Avoid direct exposure to alkaline conditions, use in neutral conditions is recommended - Ensure that the O-ring is in place on the valve - If the coil is used as independently mounted control, the end-user shall use a plastic cable gland with strain relief © Danfoss | DCS (az) | 2018.11 IC.PI.200.&2.02 | 1 7B 6B Danfoss 18F60 B 8B 40 - 50 Ncm (0.30 − 0.39 lb-ft) 9B 10B 90° 90° 250 - 375 Ncm (1.85 − 2.77 lb-ft) C 50 - 60 Ncm (0.39 − 0.44 lb-ft) 7C 6C Danfoss 18F61 OFF 8C 40 - 50 Ncm (0.30 − 0.39 lb-ft) 9C 80 - 90 Ncm (0.59 − 0.66 lb-ft) 10C 320 - 370 Ncm (2.36 − 2.73 lb-ft) Visit www.products.danfoss.com for further technical data Para más información, visite www.products.danfoss.es Rendez-vous sur le site www.products.danfoss.fr pour plus de données techniques © Danfoss | DCS (az) | 2018.11 IC.PI.200.&2.02 | 2
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement