With its torque motor, three-phase motor, and proportional solenoid valve, this amplifier provides accurate and responsive control in demanding environments. The device's BRIDGE, LOCAL, and EMERGENCY operation modes allow for flexible adaptation to different system requirements, ensuring optimal performance in various scenarios.
The FU-Amplifier Proportional AS stands out with its comprehensive alarm system, which promptly notifies users of any irregularities or faults, enabling timely corrective actions. Its user-friendly interface and intuitive operation simplify setup and maintenance, minimizing downtime and maximizing efficiency.
Advertisement
Advertisement
R
Anschütz
FU-Amplifier Proportional AS
Type 139-159 NG001, NG002, and NG003
Operation
Edition: February 04, 2013
Raytheon Anschütz GmbH
Postfach 1166
D - 24100 Kiel
Germany
Tel +49-4 31-30 19-0
Fax +49-4 31-30 19-840
Email [email protected] www.raytheon-anschuetz.com
4199.DOC010102
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu
Schadenersatz.
Toute communication ou reproduction de ce document, toute exploitation ou communication de son contenu sont interdites, sauf autorisation expresse. Tout manquement à cette règle est illicite et expose son auteur au versement de dommages et intérêts.
Copying of this document, and giving it to others and the use or communication of the contents thereof, is forbidden without express authority. Offenders are liable to the payment of damages.
Sin nuestra expresa autorización, queda terminantemente prohibida la reproducción total o parcial de este documento, así como su uso indebido y/o su exhibición o comunicación a terceros. De los infractores se exigirá el correspondiente resarcimiento de daños y perjuicios.
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
Change History
Date
February 04, 2013 First edition
May 03, 2013
Change
STEERING
CONTROL
___________________________________________________________________________________________________________________________
Edition: February 04, 2013 I 4199.DOC010102
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
Content
NOTES ON THE OPERATING INSTRUCTIONS ......................................................... 2-1
Table of F igures
Table of Tables
_________________________________________________________________________________________________________________________________
4199.DOC010102 II Edition: February 04, 2013
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
Abbreviations and Acronyms
CAN Controller Area Network
CPU Central Processing Unit
DC
DOC
EBP
ESD
FU
NFU
NG pt stb
Direct Current
Document
Earth Bonding Point
Electrostatic Sensitive Device
Follow Up
Non Follow Up
Normgerät (Standard device) port starboard
STEERING
CONTROL
___________________________________________________________________________________________________________________________
Edition: February 04, 2013 III 4199.DOC010102
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
G eneral notes and S afety notes
In case of error indications do not perform a repair immediately. First switch off and on the device and/or system.
Second check the all cables to/from the device or system and at least perform a repair.
ESD = Electrostatic Sensitive Device
EBP
(Earth Bonding Point)
Dissipative mating work surface
Devices/assemblies which are labelled as shown are electrostatic sensitive.
This label indicates that handling or use of this item may result in damage from ESD if proper precautions are not taken.
To perform installation and/or calibration work appropriate protective measures must be deployed.
All necessary equipment for this protective measures can be supplied
(on special order) with the RAYTHEON Anschütz Ident.-Number 1.990106
_________________________________________________________________________________________________________________________________
IV Edition: February 04, 2013 4199.DOC010102
1
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
STEERING
CONTROL
G eneral
Unit overview
The FU Amplifier Proportional AS for proportional rudder control is the central component of the rudder control system. It controls the hydraulic valves of the steering gear until the rudder actual value has reached the set value of the rudder.
The FU Amplifier Proportional AS operates as a constant regulator, i.e., the hydraulic valves are opened less as the control deviation decreases and the rudder movement speed is reduced.
The FU Amplifier Proportional AS controls3-phase DC motors, torque motors or proportional valves. As set rudder input FU-tillers, NFU tillers or autopilots can be used. In addition a NFU operation via push buttons on the FU-Amplifier Proportional
AS itself is possible.
Figure 1-1
FU Amplifier Proportional AS
___________________________________________________________________________________________________________________________
Edition: February 04, 2013 1-1 4199.DOC010102
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
User manual
This current user manual includes all the operating procedures.
Service manual
There is also a service manual available in addition to this user manual. It includes:
- Information on installation and initial startup
- Information on care, maintenance and repair
- A description of the FU Amplifier Proportional AS
__________________________________________________________________________________________________________________________________
4199.DOC010102 1-2 Edition: February 04, 2013
2
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
Notes on the operating ins tructions
Explanation of the symbols used
BRIDGE
Lamp
off
BRIDGE
Lamp o
n
Switch operation
STEERING
CONTROL
___________________________________________________________________________________________________________________________
Edition: February 04, 2013 2-1 4199.DOC010102
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
Intentionally left blank
__________________________________________________________________________________________________________________________________
4199.DOC010102 2-2 Edition: February 04, 2013
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
STEERING
CONTROL
3 Operation
3.1
G eneral
The FU Amplifier Proportional AS is operated from the bridge in normal operation
(operation mode BRIDGE). Operation mode LOCAL is only used for servicing work or emergencies.
The current operating mode is indicated at the bridge.
3.2
S witching on
The FU Amplifier Proportional AS does not have its own ON/OFF switch. There are two options available to switch the unit on, and these must be determined during the planning stage:
1. Switching on the status contact “Pump ON”:
The FU Amplifier Proportional AS is supplied by the same power supply as the steering gear. The FU Amplifier Proportional AS is then activated by the status signal
“Pump ON”.
2. Switching on via the mains power supply:
Contact “Pump ON” is jumpered in the unit, and thus the FU Amplifier Proportional AS is switched on when the power supply is switched on (via the pump selector switch).
Operation mode B R IDG E 3.3
Table 3-1
Operation mode BRIDGE (indication)
Operation
BRIDGE
BRIDGE
Displays
LOCAL
Notes / Comments
Modes of operation:
1) Steering mode selector switch ‘NFU Direct’ means:
Steering control by the main
NFU-Tiller
2) Steering mode selector switch ‘Main’ means:
Stering control by the activated CAN Bus unit
(Handwheel, Autopilot, or
Tiller).
___________________________________________________________________________________________________________________________
Edition: February 04, 2013 3-1 4199.DOC010102
3.4
3.5
3.6
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
Operation mode L OC AL
Table 3-2
Operation mode LOCAL (indication)
Operation
PORT
LOCAL
BRIDGE
PORT
Displays
LOCAL
STBD
Notes / Comments
Operation mode selector switch in the LOCAL position.
Control is done by the buttons on the FU amplifier
The rudder moves to port as long as the button is held down until the rudder limit position is reached.
STBD
PORT STBD
The rudder moves to starboard as long as the button is held down until the rudder limit position is reached.
LOCAL: The steering gear is controlled from the steering gear compartment.
BRIDGE: The steering gear is controlled from the bridge.
Note:
The operation mode of the FU Amplifier Proportional AS is indicated at the alarm panel (e.g. NAUTOALARM unit) via potential-free contacts. This status is also distributed via the CAN-Bus and can be displayed by means of an Alarm Signal unit
AS, type 135-111 alternatively
Operation mode E ME R G E NC Y
If the steering gear is provided with an emergency switch, it is possible to deactivate the FU Amplifier Proportional AS by use of the switch.
S witching off
The FU Amplifier Proportional AS does not have its own ON/OFF switch. It is automatically switched off when the associated pump of the steering gear is switched off.
__________________________________________________________________________________________________________________________________
4199.DOC010102 3-2 Edition: February 04, 2013
4
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three phase motor
- Proportional solenoid valve
STEERING
CONTROL
Dis turbed operation
Disturbed operation of the FU Amplifier Proportional AS is indicated at the alarm panel (e.g., NAUTOALARM unit) via potential-free contacts
.
These error messages are also distributed via the CAN-Bus and can be displayed by means of a Signal Unit
AS alternatively.
Table 4-1 Alarm overview
Display
FU FAIL
System failure
HYDRAUL.
LOCK
Meaning
Operation in ‘ Main’ steering mode is not possible.
•
Failure of the power supply.
•
CPU failure.
•
Internal voltage failure
(5V DC /±15V DC/
+24V DC/+36V DC
•
Overcurrent/ short circuit
•
CAN Bus failure
Action
•
Switch to
‘NFU Direct’ steering mode.
The steering gear drive does not follow the rudder command.
Switch OFF the effected pump system and switch
ON the redundant pump system.
Comment
•
Troubleshooting
(see Service
Manual)
•
The overcurrent
monitoring unit
works independatly
and is detected by
software.
Once the
overcurrent has
been detected, the
FU Amplier
Proportional AS is
automatically
reactivated. This
procedure is r
epeated erver 2
seconds; after 5
attempts “FU FAIL”
is triggered.
•
Check the
hydarulic system.
•
Check parameters
for Hydr. Lock
alarm (PA14, PA15
see Service
Manual)
__________________________________________________________________________________________________________________________________
4199.DOC010102 4-1 Edition: November 15, 2012
FU-Amplifier P
r
oportional AS
Type 139-159
- Torque motor
- Three-phase motor
- Proportional solenoid valve
Display
STEERING
FAILURE
WIRE
BREAK
Meaning
The actual rudder does not follow the rudder command.
Action
•
Switch to
‘NFU Direct’
steering mode.
-or-
•
Switch OFF the
effected pump
system and
switch ON the
redundant pump
system.
Wire break in the steering gear control loop.
The rudder stopps.
Switch to ‘NFU
Direct’ steering mode.
Comment
•
Check the
hydraulic system.
•
Check parameters
for Steering Fail
alarm (PA16, PA17
and PA20, see
Service Manual).
•
Check the wiring.
•
Troubleshooting
(see Service
Manual).
__________________________________________________________________________________________________________________________________
4199.DOC010102 4-2 Edition: February 04, 2013
Download
Advertisement
Key features
Precise control of torque motor, three-phase motor, and proportional solenoid valve
Versatile operation modes (BRIDGE, LOCAL, EMERGENCY) for adaptability
Comprehensive alarm system for prompt fault detection
User-friendly interface for ease of setup and maintenance
Frequently asked questions
The FU-Amplifier Proportional AS offers three operation modes: BRIDGE, LOCAL, and EMERGENCY, providing flexibility for various system requirements.
The comprehensive alarm system promptly notifies users of irregularities or faults, enabling timely corrective actions and minimizing downtime.
Yes, the FU-Amplifier Proportional AS features a user-friendly interface and intuitive operation, simplifying setup and maintenance, reducing downtime, and maximizing efficiency.