The JSFDHWK AR09JSFDHWK/CV and JSFDHWK AR12JSFDHWK/CV air conditioners are designed to provide efficient and comfortable cooling. They feature a 2 step cooling system, single user mode, and a uniquely stylish Crystal Gloss design. It also includes Smart Wi-Fi, Smart Installation, and Smart Check features for easy control and troubleshooting.
PDF
Download
Document
Advertisement
Advertisement
Basic Code: AR12HSSDPWKNEE AR18HSFSAWKXEU Model Code: AR09JSFDHWKNCV AR09JSFDHWKXCV AR12JSFDHWKNCV AR12JSFDHWKXCV 5. Control Exploded Views And Part List Contents 1. Precautions ············································································································· 1-1 1-1 Installing the air conditioner ·························································································································· 1-2 Power supply and circuit breaker················································································································· 1-3 During operation ················································································································································ 1-4 Disposing of the unit ········································································································································· 1-5 Others ······································································································································································ 1-1 1-1 1-1 1-2 1-2 2. Product Specifications ······························································································· 2-1 2-1 The Feature of Product ····································································································································· 2-2 Product Specifications ······································································································································ 2-3 The Comparative Specifications of Product····························································································· 2-4 Accessory and Option Specifications ········································································································· 2-1 2-2 2-3 2-4 3. Alignment and Adjustments ········································································ 3-1 3-1 Test Mode ······························································································································································· 3-2 Outdoor LED Display Error and Check Method ····················································································· 3-3 Setting Option Setup Method······················································································································· 3-4 Setting Option Setup Method······················································································································· 3-1 3-2 3-5 3-9 4. Disassembly and Reassembly ······································································ 4-1 4-1. Indoor Unit···························································································································································· 4-2 4-2. Outdoor Unit························································································································································ 4-12 5. Control Exploded Views And Part List ························································ 5-1 5-1 WIFI Case································································································································································· 5-1 5-2 ASSY Control In ·········································································································· ···································· 5-3 Assy Control Out ················································································································································ 5-2 5-3 6. Electrical Parts List ························································································ 6-1 6-1 INDOOR MAIN PCB (DB92-02873C) ········································································································· 6-2 INDOOR SUB PBA(DB92-02874A)················································································································· 6-3 OUTDOOR MAIN PBA(DB92-02866A)········································································································· 6-1 6-5 6-7 7. Wiring Diagram ······························································································ 7-1 7-1 Indoor Unit····························································································································································· 7-2 Outdoor Unit ························································································································································ 7-3 ASSY WIFI KIT ························································································································································ Samsung Electronics 7-1 7-2 7-3 1 Contents 8. PCB Diagram ·································································································· 8-1 8-1 Indoor Unit····························································································································································· 8-2 Outdoor PCB ························································································································································ 8-3 Wire connecting the indoor unit terminal blocks ················································································· 8-1 8-2 8-3 9. Operating Instructions·················································································· 9-1 9-1 Name of Each Part ·············································································································································· 9-2 Wireless Remote Control-Buttons and Display······················································································· 9-1 9-2 10. Troubleshooting ·························································································· 10-1 10-1 Items to be checked first ······························································································································· 10-1 10-2 Communication Error ····································································································································· 10-2 10-3 PCB Inspection Method ································································································································· 10-37 10-4 ASSY WIFI KIT Inspection Method ············································································································· 10-39 11. Block Diagram ····························································································· 11-1 11-1 Indoor unit ·························································································································································· 11-1 11-2 Outdoor unit······················································································································································· 11-2 12. Reference Sheet ··························································································· 12-1 12-1 Low Refrigerant Pressure Distribution····································································································· 12-2 Pressure & Capacity mark······························································································································ 12-3 Q & A for Non-trouble····································································································································· 12-4 Cleaning /Filter Change ································································································································· 12-5 Installation ··························································································································································· 12-6 Installation Diagram of Indoor Unit and Outdoor Unit ···································································· 2 12-1 12-1 12-2 12-5 12-6 12-7 Samsung Electronics 1. Precautions 1-1 Installing the air conditioner O Uses should not install the air conditioner by themselves. Ask the dealer or authorized company to install the air conditioner except window-type air conditioner in U.S.A and Canada. O If you don't install the air conditioner properly, it may cause a fire, a water leakage or an electric shock. O You must install the air conditioner according to the national wiring regulations and safety regulations. O Install the indoor unit higher than 2.5m from the floor to avoid the injury caused by the operation of the fan. (except the window-type air conditioner) O The manufacturer is not responsible for any accidents or injury caused by an incorrect installation. O When installing the built-in type air conditioner, keep all electric cables such as the power cable and the connection cord in pipes, ducts, or cable channels to protect them from the danger of impact or any other incidents. 1-2 Power supply and circuit breaker O If the power cord of the air conditioner is damaged, it must be replaced by the manufacturer or a qualified person in order to avoid a hazard. O The air conditioner must be plugged into an independent circuit if applicable or connect the power cable to the auxiliary circuit breaker. An all pole disconnection form the power supply must be incorporated in the fixed wiring with a contact opening of>3mm. O Do not extend an electric cord to the air conditioner. O The air conditioner must be plugged in after you complete the installation. 1-3 During operation O Do not repair the air conditioner at your discretion. It is recommended to contact a service center directly. O Never spill any kind of liquid on the air conditioner. If this happens, turn off the air conditioner and contact an authorized service center. O Do not insert anything between the airflow blades to prevent damage of the inner fan and consequent injury. Keep children away from the air conditioner. O Do not place any obstacles in front of the air conditioner. O Do not spray any kind of liquid into the indoor unit. If this happens, turn off the air conditioner and contact a service center. O Make sure that the air conditioner is well ventilated at all times. Do not place a cloth or other materials over it. O Remove the batteries if you don't use the remote control for a long time. (If applicable) O Use the remote control within 7 meters from the indoor unit. (If applicable) Samsung Electronics 1-1 1-4 Disposing of the unit O Before the throwing out the air conditioner, remove the batteries from the remote control. O When you dispose of the air conditioner, consult your dealer. If pipes are removed incorrectly, refrigerant may blow out and cause air pollution. When it contacts with your skin, it can cause skin injury. O The package of the air conditioner should be recycled or disposed of properly for environmental reasons. 1-5 Others O O O O 1-2 Never store or load the air conditioner upside down or sideways to prevent the damage to the compressor. Young children or infirm persons should be always supervised when they use the air conditioner. Max current is measured according to IEC standard for safety. Current is measured according to ISO standard for energy efficiency. Samsung Electronics 2. Product Specifications 2-1 The Feature of Product 2 step cooling - Get cool quickly and keep cool comfortably without shivering Single user mode - No worrying about the electricity bill, even using it when you're alone. Crystal gloss design - Uniquely stylish and innovative design to enhance your life and home Smart Wi-Fi - Control air conditioner anytime and anywhere Smart Installation Smart Check - Don’t worry about the trouble-shooting in your home Triple Protector Plus - Use longer without damage in unsuitable conditions Easy Installation - Secure the easy Installation of Indoor unit and pipe connection Easy Filter Samsung Electronics 2-1 2-2 Product Specifications Model ITEM AR09JSFDHWK/CV Indoor Unit Type Capacity Running Frequency Performance Noise Energy Efficiency Ratio Pow Operating Current Power Factor Outer Dimension KW 0.90/2.64/3.81 0.90/3.52/4.00 0.80/3.69/6.10 0.80/4.00/6.60 Cooling Hz 12/32/50 12/56/93 Heating (Low/Std/Max) 12/50/83 12/56/93 Cooling dB (H/L) 46 47 51 53 W/W (Std) 4630 4140 4340 4300 ph-V-Hz 1phase, 220-240V~, 50Hz 1phase, 220-240V~, 50Hz W (Low/Std/Max) 200/570/700 200/850/1150 170/850/1750 170/930/1900 1.4/2.9/3.2 1.4/4.0/5.3 1.0/3.9/7.5 1.0/4.3/8.5 70/85/90 70/85/90 70/85/90 70/85/90 Heating Cooling Heating Cooling Heating Cooling A (Low/Std/Max) Heating Cooling % (Std) Heating Width*Height *Depth mm 896*260*275 880*638*310 896*260*275 880*638*310 kg 11.2 40 11.2 40 Liquid mm 6.35 Gas mm 9.52 9.52 L*D(mm*mm) 550*20 550*20 Motor DA128A1FA-20F(Toshiba) DA128A1FA-20F(Toshiba) - - Rated Output(W) - - Oil Type Type Blower motor Cross-flow Type Rated Output(W) Heat Exchanger Refrigerant Control Unit Propeller Cross-flow Propeller Resin/steel/AC Resin/steel/AC Resin/steel/AC Resin/steel/AC - FMC 20mm FMC 20mm 2ROWx14STE 1R - 56STEP 2ROWx14STE 1R - 56STEP Px705 Px705 FP1.4 Louver FP1.4 Louver EEV EEV Freezer Oil Capacity cc - - Refrigerant to Change(R410A) g 1150 1150 Proterction Device(OLP) Operation condition range 2-2 6.35 Type Type Compressor Wall-mounted (Low/Std/Max) Drain Hose Size Outoor Unit Wall-mounted Cooling Weight(Net) Refrigerant Pipe AR12JSFDHWK/CV Indoor Unit Heating Power Power Consumtion Outoor Unit None None Cooling 10~46(Cooling) 10~46(Cooling) Heating -15~24(Heating) -15~24(Heating) Samsung Electronics 3 Air Purifying System Noise Outer Dimension Net Weight Design ITEM Indoor Unit(Kg) Outdoor Unit(Kg) Indoor Unit(mm) Outdoor Unit(mm) Indoor Unit(dB) Outdoor Unit(dB) Filter Outdoor Unit Indoor Unit MODEL 11.2 40 896*260*275 880*638*310 46 51 FULL HDFILTER Develop Model AR09JSFDHWK/CV 11.2 40 896*260*275 880*638*310 47 53 FULL HDFILTER Develop Model AR12JSFDHWK/CV 3 DB93-15169G DB68-04937A MANUAL USERS DB68-04419A 3. Alignment and Adjustments 3-1 Test Mode Q How to Approach Test Mode You can approach the test mode by pressing the on/off switch of indoor unit for 5 seconds. Q Test mode operation option After installing the air conditioner, check whether each subordinate is normally operated or not by operating the test mode. When an Error occurs, display the Error Mode. ● Operation Mode : Cool mode. operate the cool mode by operating the compressor by force without the compressor ON/OFF according to the set temperature/indoor temperature. (Do not follow the antifreeze control) ● Up-down louver : Up-down swing mode ● Indoor Fan : Turbo ● ● Note Because the teat mode operate the cool mode by force not related to the set temperature / indoor temperature, check whether each subordinate is operated normally or not after completing installation and must turn off the power of the air conditioner. Samsung Electronics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utdoor LED Display Error and Check Method Samsung Electronics 3-3 Setting Option Setup Method ex) Option No. : Note : SEG1, SEG7, SEG13, SEG19 need not to be pressed in, so in fact the Option No. we should press in is as below. SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 SEG25 SEG26 SEG27 SEG28 SEG29 SEG30 SEG31 SEG32 SEG33 SEG34 SEG35 SEG36 SEG37 SEG38 SEG39 SEG40 SEG41 SEG42 SEG43 SEG44 SEG45 SEG46 SEG47 SEG48 Step 1 Enter the Option Setup mode. 1. Tack out the batteries of remote control. 2. Press the temperature button simultaneously and insert the battery again. 3. Make sure the remote control display shown as . Step 2 Enter the Options Setup mode and select your options asscording to the following procedure. Samsung Electronics 3-8 Step 3 Upon completion of the selection, check you made right selections. Press the Mode Selection key to set the display part and check the display part. → The display part shows like below when each time you press Mode button. Step 4 Pressing the ON/OFF button ( ) . When pressing the operation ON/OFF key with the direction of remote control for unit, the sound ’’Ding’’ or ’ and the OPERATION ICON( ) lamp of the display is flickering at the same time, then the input of option is completed. (If the deriving sound isn’t heard, try again pressing the ON/OFF button.) 3-9 Samsung Electronics Step 5 Enter the Options Setup mode and select your options asscording to the following procedure. Step 1 (Enter the Option Setup mode) is executed. (Seg25 ~ 48 for setting remote control Setup) Push the Mode button to set the display panerl to 2. Every time you push the button, the display panel reads . . . Push the repeatedly. Mode button to set the display panerl to 1. Every time you push the button, the display panel reads . . . Samsung Electronics repeatedly. 3-10 Model AR09JSFDHWK/CV AR12JSFDHWK/CV 11 1~6 011025 011025 7~12 156ABD 166ABD 13~18 271A25 272328 19~24 370934 370934 25~30 033E3F 033F3F 31~36 102032 102F38 37~42 200000 200000 43~48 300001 300001 3-12 Download connector (10pin) 3-13 4. Disassembly and Reassembly Q Necessary Tools Item Remark +SCREW DRIVER MONKEY SPANNER - SCREW DRIVER Samsung Electronics 4-1 4-1. Indoor Unit No Parts Procedure 1 PANEL-FRONT 1) Stop the driving of air conditioner and shut off main power supply. Remark 2) Detach FILTER PRE from the PANEL FRONT. 3) Cover Panel is assembled on bottom of indoor unit as shown in the figure. Remove the Cap Screw as shown on the right side and then remove the screw and separate the Cover Panel. 4-2 Samsung Electronics No Parts Procedure Remark 4) Cover Panel is fixed to body by Hook in center area and side area. Center area Side area Side area HOOK 9/12K 18/24/30K 5) Separate the hook after pushing both end of Cover Panel as shown in the figure. (Watch out for the damage of the hook) 6) Raise front part upward obliquely as shown in the figure and then remove the hooks. Samsung Electronics 4-3 No Parts Procedure Remark Caution: Assembly of Cover Panel after service end. - Reassembly is in the reverse order of the removal. - Piping and drain hose must be careful not to damage and Progress must be done with both hands. Hook (Side) Hook (Center) Screw Cap Screw 4-4 Samsung Electronics No Parts Procedure Remark 7) To detach the PANEL-FRONT from the main frame, unfasten 2 screws at the bottom. (use + Screw Driver) 8) To detach the COVER-PANEL from the main frame, loosen 4 HOOK Structures. When separate the hook : Use the (-) screw Driver. (-)Screw Driver Insert the hook and then pull the hook as shown on the right side. (Watch out for the damage of the hook) Samsung Electronics 4-5 No Parts Procedure Remark 9) Remove the Panel Frame from the Main Frame as shown on the right side. 10) Remove the WIFI KIT connector. WIFI KIT connector is located of Panel Front. (For model with WIFI KIT) 4-6 Samsung Electronics No Parts 5 EVAPORATOR Procedure Remark 9) Take off the CASE-CONTROL from the main frame after loosen the remaining connector. Caution: When you separate the connector, pull pressing the locking button. 3 4-8 TRAY DRAIN 1) To detach TRAY-DRAIN from the main frame, pull the bottom of the TRAY-DRAIN towards you. Samsung Electronics No Parts 4 Evaporator Procedure Remark 1) Detach the HOLDER PIPE. 2) Unfasten the screw at the left side. (use + Screw Driver) 3) Unfasten the screw at the right side. (use + Screw Driver) 4) To detach Evaporator from the main frame, pull the bottom of the Evaporator towards you. Samsung Electronics 4-9 No Parts 5 FAN MOTOR & CROSS FAN Procedure Remark 1) Unfasten the screw. (use + Screw Driver) 2) Detach the FAN Motor case. 3) Unfasten the screw a little. (use + Screw Driver) 4) Pull the CROSS-FAN to the left side. 4-10 Samsung Electronics No Parts 6 Assy SPI Lamp Procedure Remark 1) Remove the Assy SPI Lamp from the Back Body as shown on the right side. Caution: - Confirm Seal of backside necessarily after replace of Assy SPI Lamp. - Seal should be close adhesion to SPI Lamp. - Measure as shown on the right side since replace. (If the seal is not close adhesion perfectly : Defectiveness can happen) Samsung Electronics 4-11 2 2 4-8 Samsung Electronics %JTBTTFNCMZBOE3FBTTFNCMZ /P 1BSUT 1SPDFEVSF 3FNBSL -PPTFOGJYJOHTDSFXT$$8 PGUIF$BCJOFU 'SPOU -PPTFOTDSFXT$$8 GJYFEPOUIF(VJEF $POEFOTFS Samsung Electronics 4-9 %JTBTTFNCMZBOE3FBTTFNCMZ /P 1BSUT 'BO .PUPS 1SPDFEVSF 3FNBSL %FUBDIUIF/VU'MBOHFMJLFUIFQJDUVSFPO UIFSJHIUTJEF5VSODMPDLXJTFCFDBVTFUIF TDSFXJTMFGUIBOEFE %FUBDIUIF'BO1SPQFMMFS -PPTFOGJYJOHTDSFXT$$8 UPEFUBDI UIF.PUPS %JTDPOOFDUUIFXJSFCFUXFFO"TTZ$POUSPM 0VUBOE.PUPS -PPTFOGJYJOHTDSFXT$$8 BOEEFUBDIUIF #SBDLFU.PUPS 4-10 Samsung Electronics %JTBTTFNCMZBOE3FBTTFNCMZ /P 1BSUT 1SPDFEVSF "TTZ$POUSPM0VU %FUBDITFWFSBMDPOOFDUPSTGSPNUIF "TTZ$POUSPM0VU %FUBDITFWFSBMDPOOFDUPSTGSPNUIF1$#PG "TTZ$POUSPM0VU 1VMMVQUIF"TTZ$POUSPM0VU )FBU&YDIBOHFS 3FMFBTFUIFSFGSJHFSBOUBUGJSTU -PPTFOGJYJOHTDSFX$$8 BOEEFUBDIUIFTUFFM CBS %JTBTTFNCMFUIFQJQFTJOCPUIJOMFUBOEPVUMFU XJUIXFMEJOHUPSDL 3FNBSL #FGPSFZPVEJTBTTFNCMFUIFQJQFTBOE $POEFOTFSCFTVSFUIBUUIFSFTIPVMECF OPSFGSJHFSBOUSFNBJOFEJOUIFVOJU -PPTFOGJYJOHTDSFX$$8 BOEEFUBDIUIF)FBU &YDIBOHFS Samsung Electronics 4-11 /P 1BSUT $PNQSFTTPS 1SPDFEVSF 3FNBSL %JTBTTFNCMFUIF'FMU$PNQ4PVOE -PPTFOUIFGJYJOHOVU$$8 BOEEFUBDIUIF $PNQSFTTPS-FBE8JSF -PPTFOUIFCPMUT$$8 BUUIFCPUUPNPG $PNQSFTTPSMJLFUIFQJDUVSFPOUIFSJHIUTJEF 4-12 Samsung Electronics 5. Disassembly WIFI 5-1 WIFI Case No Parts Procedure 1 CASE Separate Case-WIFI Top from Case-WIFI Button 2 BUTTON Separate Case-WIFI Top from Case-WIFI Button Remark Detach Assy Connector Wire from Case-WIFI Button 3 WIRE 4 PBA Samsung Electronics *Caution When you separate the connector , pull press -ing the locking button Separate PBA WIFI from Case-WIFI Button 5-1 5-2 ASSY CONTROL IN 10 25 5 6 7 8 9 34 27 23 2 3 4 28 20 29 31 24 26 1 21 11 33 22 12 32 13 19 14 18 No 16 15 CODE DB93-14734Z 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 32 33 34 5-2 17 18 Description ASSY CONTROL IN Spec Q'TY DB63-03553C Aluminum SHEET 10x10xT0.07,AL SHEET 4 DB61-05826B CASE-CONTROL IN CASE-CONTROL IN 1 DB93-14203A POWER WIRE T/B-main(power) 1 DB93-14245A EARTH WIRE EARTH WIRE 1 DB65-00326A TERMINAL BLOCK TERMINAL BLOCK 1 DB62-11656F SEAL CUTT PVC,BLACK,T1,W54 1 DB62-11680A SEAL CONTROL 1 DB68-02809A ASSY-LABEL FLOCKED,BLACK,T1,W50,54 ASSY-LABEL DB93-06677A COMMUNICATION WIRE T/B-main(485) 1 DB93-14207A FUSE WIRE power-main(12V 5V) 1 DB63-03553D Aluminum SHEET 22x22xT0.07,AL SHEET 1 DB68-33293A ASSY-LABEL ASSY-LABEL 1 DB61-05957A PLATE-CONTROL IN F03/04 1 DB68-33292A ASSY-LABEL ASSY-LABEL 1 DB91-00309A SCREW M3,L25,ZPC(WHT),SWRCH18A 1 DB61-05812A PLATE PLATE 1 6009-001001 SCREW TH,M4,L10,ZPC(WHT),SWRCH18A 3 6002-000231 SCREW M4,L12,ZPC(WHT),SWRCH18A 3 DB61-05871A HOLDER-WIRE CLAMP HOLDER-WIRE CLAMP 1 DB92-02873C MAIN PBA STD4 1 DB92-02861A POWER PBA STD11W 1 DB62-11793A SEAL CASE-LEFT SEAL CASE-LEFT 1 DB93-14208A ASSY CONNECTOR WIRE-DC power-main(310V 19V) 1 DB95-05163A ASSY THERMISTOR IN sensor 1room,2evap 1 DB93-14221A ASSY CONNECTOR WIRE-DC FJM 1 6002-000630 SCREW SCREW 2 DB93-14724A ASSY CONNECTOR WIRE-DC BLDC 1 DB93-14209A ASSY CONNECTOR WIRE-DC DISPLAY MOTOR 0 DB93-14209B DB93-14723A ASSY CONNECTOR WIRE-DC DISPLAY MOTOR 1 ASSY CONNECTOR WIRE-DC STEP MOTOR 1 1 DB93-04695A ASSY CONNECTOR WIRE-DC SPI 0 DB61-05965A PLATE CONTROL-UP PLATE CONTROL-UP 1 DB90-07859A ASSY PLATE CONTROL RIGHT 1 DB93-14205A ASSY CONNECTOR WIRE-DC Step-main(Left) 1 DB93-14211A ASSY CONNECTOR WIRE-DC WIFI 1 Samsung Electronics 5-3 Assy Control Out (DB92-03621A) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 5-4 NAME GREASE-SILICON SCREW-TAPPING SCREW-TAPPING HEAT SINK SEAL CUTT CABLE TIE LABEL BAR CODE ASSY CASE CONTROL OUT ASSY COVER CONTROL-UP ASSY CASE CONTROL ASSY-SCREW MACHINE ASSY PCB SUB ASSY MODULE ASSY PCB MAIN ASSY CONNECTOR WIRE ASSY CONNECTOR WIRE ASSY CONNECTOR WIRE-POWER ASSY CONNECTOR WIRE ASSY CONNECTOR WIRE ASSY CONNECTOR WIRE CODE 0205-000178 6002-000527 6002-000536 DB62-11646A DB62-11656B DB65-10088B DB68-02809A DB90-06308V DB90-07729A DB90-07833B DB91-00933A DB92-02836A DB92-02862A DB92-02866A DB92-02836A DB93-09493C DB93-09497E DB93-14275A DB93-14276A DB93-14277A Q'ty 0.002 1 2 1 0 2 1 1 1 1 4 0 1 1 1 1 1 1 1 1 unit REMARK Kg PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC - Samsung Electronics 6. Electrical Parts List 6-1 INDOOR MAIN PCB (DB92-02873C) Parts Code 1405-001239 2301-002032 2301-002032 3002-001139 3711-000177 3711-000203 3711-000296 3711-002001 3711-003404 3711-003845 3711-004122 3711-004236 3711-005096 3711-005097 3711-005504 DB27-00096A DB67-00942A DB68-02809A DB94-04097A 0501-000362 1404-001194 3601-001765 3711-000024 3711-000941 3711-000998 3711-000999 DB94-04098A 0402-001741 0406-001204 0406-001204 0406-001204 0501-000465 0504-001080 0504-001080 0506-000175 0506-000175 0604-001002 0604-001002 0604-001002 0801-000393 1006-001325 1202-000104 1203-006245 1203-007526 2007-000029 2007-000029 2007-000067 2007-000072 Samsung Electronics Design Loc Q701 VA71 XC71 XC72 BZ61 CN21 CN75 CN72 CN31 CN71 CN91 CN32 CN43 CN63 CN62 CN51 FT71 VA71-1 LABEL BAR CODE Q801 PTC2 F701 CN76 CN81 CN77 CN61 D701 CD81 CD82 CD83 Q702 Q601 Q802 IC05 IC06 PC03 PC04 PC05 IC08 IC07 IC11 IC03 IC02 R850 R851 R713 R717 Parts Dsecription Quantity TR-POWER 1 VARISTOR 1 C-FILM,LEAD-PPF 1 C-FILM,LEAD-PPF 1 BUZZER-PIEZO 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 COIL CHOKE 1 CAP 1 LABEL BAR CODE 1 ASSY PCB AUTO 1 TR-SMALL SIGNAL 1 THERMISTOR-PTC 1 FUSE-ETC 1 HEADER-BOARD TO CABLE 1 HEADER-BOARD TO CABLE 1 CONNECTOR-HEADER 1 1 HEADER-BOARD TO CABLE ASSY PCB SMD 1 DIODE-RECTIFIER 1 DIODE-TVS 1 DIODE-TVS 1 DIODE-TVS 1 TR-SMALL SIGNAL 1 TR-DIGITAL 1 TR-DIGITAL 1 TR-ARRAY 1 TR-ARRAY 1 PHOTO-COUPLER 1 PHOTO-COUPLER 1 PHOTO-COUPLER 1 IC-CMOS LOGIC 1 IC-BUS TRANSCEIVER 1 IC-VOLTAGE COMP. 1 IC-VOL. DETECTOR 1 IC-POSI.FIXED REG. 1 R-CHIP 1 R-CHIP 1 R-CHIP 1 R-CHIP 1 6-1 ,1'2250$,13&%'%$ FRQW 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 5&+,3 6DPVXQJ(OHFWURQLFV INDOOR MAIN PCB (DB92-02873A) 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000148 2007-000157 2007-000162 2007-000162 2007-000171 2007-000171 2007-000171 2007-000171 2007-000171 2007-000171 2007-000303 2007-000385 2007-000455 2007-000475 2007-000924 2007-000924 2007-000924 2007-000939 2007-001096 2007-001313 2007-001313 2007-001313 2007-001313 2007-001313 2007-001433 2007-007313 2007-007313 2007-007313 2007-009922 2007-009922 2007-009922 2203-000257 2203-000257 2203-000438 2203-000438 6-4 R527 R528 R529 R530 R531 R532 R533 R534 R543 R544 R807 R808 R810 R824 R903 R904 R902 R820 R821 R831 R833 R835 R837 R839 R843 R702 R115 R712 R709 R112 R113 R114 R711 R714 R404 R405 R406 R410 R811 R618 R401 R402 R403 R301 R302 R303 C705 C801 C508 C516 R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Samsung Electronics ,1'2250$,13&%'%$CCFRQW '%$ '%$ '%$ & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & ; 3&%0$,1 ,& $66</$%(/0,&20 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &&(5&+,3 &$/60' &$/60' &$/60' 5(621$725&(5$0,& 3&%0$,1 $66<0,&20 ,&0,&52&21752//(5 $66</$%(/0,&20 6DPVXQJ(OHFWURQLFV 6-2 INDOOR SUB PBA(DB92-02874A) Parts Code 0609-001377 3711-004067 DB63-03547A DB94-04100A 0406-001005 2007-000029 2007-000290 2203-000206 2203-000444 DB94-04099A 2401-003107 3404-001220 DB41-01222A Samsung Electronics Design Loc RM01 CN01 COVER-SENSOR CD01 J1 R01 C03 C02 C01 SW01 PCB SUB Parts Description MODULE REMOCON HEADER-BOARD TO CABLE COVER-SENSOR ASSY PCB SMD DIODE-TVS R-CHIP R-CHIP C-CER,CHIP C-CER,CHIP ASSY PCB AUTO C-AL SWITCH-TACT PCB SUB Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 6-5 OUTDOOR MAIN PBA(DB92-02866A) - 6-12 (cont.) modelCode Design Loc Parts Description Quantity 0202-001338 0202-001463 0204-004665 0204-005794 1404-001498 1405-000154 1405-000154 1405-001239 1405-001239 2201-000540 2201-002002 2201-002002 2201-002002 2201-002002 2301-001285 2301-001285 2306-000123 2401-004874 2401-004874 2401-004874 3501-001154 3501-001154 3501-001279 3711-000177 3711-000203 3711-000296 3711-000760 3711-002001 3711-003404 3711-003843 3711-007656 3711-007659 3711-007817 3712-001047 3712-001139 3712-001139 4719-002483 4719-002484 DB27-00097A DB61-05296A DB61-05916A DB68-02809A DB94-04084A 0504-001044 2201-002427 2401-000303 2401-000303 2401-001838 2401-002438 SOLDER-BAR SOLDER-WIRE FLUX SOLVENT PTC020 VA002 VA003 VA001 VA401 C425 C004 C005 C012 C013 C001 C006 C412 CE101 CE102 CE103 RY022 RY030 RY021 CN301 CN030 CN901 CN551 CN201 CN150 CN251 CN402 CN401 CN501 CN003 CN001 CN002 PFC050 IPM400 FT001 SUPPORT-IC SUPPORT-PCB - SOLDER-BAR SOLDER-WIRE FLUX SOLVENT THERMISTOR-PTC VARISTOR VARISTOR VARISTOR VARISTOR C-CERAMIC,DISC C-CERAMIC,DISC C-CERAMIC,DISC C-CERAMIC,DISC C-CERAMIC,DISC C-FILM,LEAD-PPF C-FILM,LEAD-PPF C-FILM,LEAD-PPF C-AL C-AL C-AL RELAY-MINIATURE RELAY-MINIATURE RELAY-POWER HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO BOARD CONNECTOR-TERMINAL CONNECTOR-TERMINAL CONNECTOR-TERMINAL POWER MODULE POWER MODULE COIL CHOKE SUPPORT-IC SUPPORT-PCB LABEL BAR CODE ASSY PCB AUTO TR-DIGITAL C-CERAMIC,DISC C-AL C-AL C-AL C-AL 0.47 4.27 0.43 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Q151 C901 CE162 CE163 CE151 CE902 Samsung Electronics OUTDOOR MAIN PBA(DB92-02866A) - (cont.) 2401-003224 2401-003585 3601-001538 3711-000015 3711-000024 3711-000879 3711-000880 3711-000998 3711-000999 4715-001093 DB94-04085A 0202-001459 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0401-001099 0402-001795 0403-001499 0403-001499 0404-001020 0404-001020 0406-001204 0406-001204 0406-001204 0501-000465 0504-001008 0504-001008 0504-001008 0504-001008 0504-001080 0506-000175 0506-000175 0506-000175 0601-002423 0601-002955 0601-002956 0601-002956 0604-001172 6-12 CE152 CE901 F001 CN203 CN202 CN152 CN151 CN701 CN204 DSA001 SOLDER-CREAM D020 D021 D030 D152 D153 D454 D500 D501 D502 D503 D504 D505 D507 D508 D904 D905 D903 ZD401 ZD420 D491 D492 TD301 TD302 TD303 Q551 Q351 Q352 Q901 Q903 Q902 IC061 IC701 IC702 LED801 LED803 LED551 LED802 PC151 C-AL C-AL FUSE-AXIAL LEAD HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE HEADER-BOARD TO CABLE CONNECTOR-HEADER HEADER-BOARD TO CABLE SURGE ABSORBER ASSY PCB SMD SOLDER-CREAM DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-SWITCHING DIODE-RECTIFIER DIODE-ZENER DIODE-ZENER DIODE-SCHOTTKY DIODE-SCHOTTKY DIODE-TVS DIODE-TVS DIODE-TVS TR-SMALL SIGNAL TR-DIGITAL TR-DIGITAL TR-DIGITAL TR-DIGITAL TR-DIGITAL TR-ARRAY TR-ARRAY TR-ARRAY LED LED LED LED PHOTO-COUPLER 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Samsung Electronics OUTDOOR MAIN PBA(DB92-02866A) 0604-001172 0604-001172 0801-000393 1006-001325 1201-002946 1203-002835 1203-002986 1203-004967 2007-000043 2007-000070 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000074 2007-000076 2007-000076 2007-000076 2007-000076 2007-000076 2007-000076 2007-000076 2007-000076 2007-000076 2007-000076 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 6-12 PC351 PC352 IC302 IC301 IC451 IC154 IC155 IC502 R424 R309 R152 R210 R213 R233 R234 R401 R402 R403 R404 R405 R406 R407 R420 R422 R516 R519 R562 R153 R255 R256 R257 R258 R352 R353 R512 R567 R904 R303 R307 R308 R351 R354 R503 R504 R505 R508 R509 R515 R529 R530 (cont.) PHOTO-COUPLER PHOTO-COUPLER IC-CMOS LOGIC IC-BUS TRANSCEIVER IC-OP AMP IC-POSI.FIXED REG. IC-POSI.FIXED REG. IC-VOL. DETECTOR R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Samsung Electronics OUTDOOR MAIN PBA(DB92-02866A) 2007-000078 2007-000078 2007-000078 2007-000078 2007-000078 2007-000080 2007-000082 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000084 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000090 2007-000109 6-12 R556 R557 R558 R560 R563 R522 R421 R211 R212 R214 R215 R216 R217 R218 R219 R220 R408 R501 R506 R507 R510 R511 R517 R518 R520 R521 R523 R524 R525 R526 R527 R534 R535 R536 R903 R301 R302 R304 R305 R528 R532 R533 R551 R552 R553 R554 R555 R559 R565 R531 (cont.) R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Samsung Electronics OUTDOOR MAIN PBA(DB92-02866A) 2007-000116 2007-000124 2007-000140 2007-000140 2007-000143 2007-000143 2007-000143 2007-000143 2007-000143 2007-000143 2007-000143 2007-000143 2007-000143 2007-000143 2007-000143 2007-000143 2007-000143 2007-000148 2007-000148 2007-000148 2007-000170 2007-000239 2007-000256 2007-000256 2007-000256 2007-000300 2007-000385 2007-000385 2007-000455 2007-000455 2007-000491 2007-000536 2007-000537 2007-000537 2007-000537 2007-000537 2007-000537 2007-000614 2007-000614 2007-000614 2007-000614 2007-000614 2007-000614 2007-000614 2007-000614 2007-000651 2007-000683 2007-000683 2007-000683 2007-000763 6-12 R306 R564 R202 R205 R207 R221 R222 R223 R224 R225 R226 R227 R228 R229 R230 R231 R232 R203 R204 R206 R201 R491 R455 R457 R468 R901 R101 R105 R251 R253 R561 R492 R154 R155 R156 R157 R158 R252 R254 R469 R470 R471 R472 R473 R474 R475 R454 R459 R466 R476 (cont.) R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Samsung Electronics OUTDOOR MAIN PBA(DB92-02866A) 2007-000763 2007-000872 2007-000872 2007-000872 2007-000924 2007-000924 2007-000924 2007-000924 2007-000924 2007-000924 2007-000979 2007-001071 2007-001175 2007-001175 2007-001175 2007-010245 2007-010245 2007-010245 2007-010245 2007-010245 2203-000236 2203-000257 2203-000257 2203-000257 2203-000257 2203-000257 2203-000257 2203-000257 2203-000257 2203-000257 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000440 2203-000783 2203-000783 2203-002002 6-12 R477 R801 R802 R803 R102 R103 R104 R106 R107 R108 R478 R902 R409 R423 R427 R410 R411 R412 R425 R426 C421 C222 C223 C224 C225 C301 C351 C352 C422 C423 C404 C405 C406 C408 C409 C410 C411 C501 C504 C505 C506 C507 C508 C510 C512 C523 C904 C455 C458 C453 (cont.) R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Samsung Electronics OUTDOOR MAIN PBA(DB92-02866A) 2203-002002 2203-002002 2203-002002 2203-002002 2203-002002 2203-002002 2203-002002 2203-002398 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-005249 2203-006158 2203-006158 6-12 C454 C459 C515 C516 C517 C518 C519 C524 C061 C151 C152 C153 C154 C162 C163 C220 C221 C251 C252 C253 C254 C302 C303 C304 C305 C306 C307 C401 C402 C403 C407 C420 C424 C460 C503 C509 C511 C514 C520 C521 C525 C526 C527 C701 C702 C703 C704 C903 C201 C203 (cont.) C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Samsung Electronics OUTDOOR MAIN PBA(DB92-02866A) 2203-006158 2203-006158 2203-006158 2203-006158 2203-006158 2203-006158 2203-006158 2203-006460 2203-006960 2203-007456 2203-007456 2203-007456 2203-007456 2203-007456 2203-007456 2203-007456 2203-007456 2203-007456 2402-001183 2402-001268 2402-001268 2402-001268 2402-001368 2402-001368 2402-001368 2802-001165 2802-001211 DB41-01227A DB91-01517A 0903-001843 DB98-31449A DB91-01534A DB09-00596A 6-12 C204 C206 C207 C208 C210 C211 C212 C522 C902 C202 C205 C209 C213 C214 C226 C227 C228 C229 CE451 CE153 CE404 CE420 CE401 CE402 CE403 X201 X501 PCB MAIN IC501 ASSY-LABEL MICOM IC201 - (cont.) C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP C-AL,SMD C-AL,SMD C-AL,SMD C-AL,SMD C-AL,SMD C-AL,SMD C-AL,SMD RESONATOR-CERAMIC RESONATOR-CERAMIC PCB MAIN ASSY MICOM IC-MICROCONTROLLER 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ASSY-LABEL MICOM 1 ASSY MICOM IC MICOM 1 1 Samsung Electronics 7.WiringDiagram 7-1IndoorUnit Samsung Electronics 7-1 7-2OutdoorUnit 7-2 Samsung Electronics 8-1 Indoor PCB ⑦ CN21 ③ CN81 ① CN61 ① CN63 ① CN62 ⑥ CN43 CN76 ⑨ CN32 ⑤ CN91 CN77 CN31 ④CN51 ⑧ CN72 CN75 ② CN71 ① CN61/CN62/CN63 STEP MOTOR ② CN71 - POWER IN ③ CN81 - SPI ④ CN51 - WI-FI MODULE #1,#3 : AC220~240V #1: SPI SIGNAL #1: DC 12V #2 : N.C #3 : DC 12V #1 : WIFI UART SIGNAL1 #2 : WIFI UART SIGNAL2 #3 : WIFI RESET SIGNAL #4 : GND #5 : DC 12V #6 : N.C ⑥ CN43 - TEMPERATURE SENSOR ⑦ CN21 - COMMUNICATION ⑧ CN72 - BLDC FAN MOTOR #1,#2 : 485 COMM SIGNAL #1 : DC 310~340V #2 : N.C #3 : AGND #4 : DC 15V #5 : FAN RPM #6 : FAN FEEDBACK #2~#5 :STEP MOTOR SIGNAL ⑤ CN91 - DISPLAY #1~#11,#14,#17~#20 : MICOM DOWN #1,#2 : ROOM SENSOR #12, #13, #15, #16 : N.C #3,#4 : EVA MID SENSOR #5,#6 : EVA IN SENSOR ⑨ CN32 - FJM/NASA CN75 - SMPS POWER IN #1~#7, #11~ #14 : FJM/NASA SIGNAL #1,#3 : AC220~240V #8 : DC 5V #2 : N.C CN76 - SMPS DC OUT (12V/GND/5V) CN77 - SMPS DC OUT (19V/GND/310V) #1 : DC 5V #1 : DC 310V~340V #9 : GND #2 : GND #2,#3 : N.C #10 : DC 12V #3 : DC 12V #4 : DC 19V~27V #5 : AGND CN31 - DOWNLOAD DOWNLOAD Samsung Electronics 8-1 8-2 Outdoor PCB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ① CN151 - SMPS INV ② CN204 - DRED ③ CN201- DOWNLOAD-MAIN ④ CN251 - SENSOR #1 : 15V #2 : GND #3 : ENABLE #1 #2 #3 #4 #5 #1 ~ #20 : DOWNLAOD #1,#2 : OUT SENSOR #3,#4 : DISCHARGE SENSOR #5,#6 : COND SENSOR ⑤ CN501 - EEPROM ⑥ CN701 - EEV-A ⑦ CN152 - SMPS MAIN ⑧ CN301 - COMMUNICATION #1 #3 #4 #5 #6 #7 #1~#4 : EEV SIGNAL #5 : 12V #1 : 12V #2 : GND #3 : 5V #1 : F1 #2 : F2 : : : : : : GND 5V EEP CS EEP_SO/MICOM RX EEP_SI_MICOM_TX EEP CLK ⑨ CN901 - FAN #1 #2 #3 #4 #5 #6 : : : : : : DC 310~340V N.C AGND DC 15V FAN RPM FAN FEEDBACK CN002 - POWER-L #1 : L 8-2 : DRED1 : DRED2 : DRED3 : GND : 5V CN401- REACTOR #1 : REACTOR1 #2 : REACTOR2 CN003 - EARTH #1 : EARTH CN030 - 4WAY #1,#3 : AC220~240V CN150 - SMPS AC #1,#3 : AC220~240V CN001 - POWER-N #1 : N CN402 - COMP #1 : W #2 : V #3 : U Samsung Electronics 8-3 Wire connecting the indoor unit terminal blocks 1. Terminal press of Ring terminal shall be set facing up before connecting wire. Is inverted 2. There shall be no empty space between Ring terminal and Screw after Clamp. If not, there exists a possibility of fire which can be caused by electric heat in the connecting part. , 8-3 Terminalhasbeencut. : Good Bad : Ring terminal is connected reversely Bad : Not clamped Screw Bad : In the gap between Ring terminal & Screw Bad : Unused Ring Terminal Samsung Electronics 9. Operating Instructions 9-1 Name of Each Part 9-1-1 Indoor Unit The design and shape are subject to change according to the model. ■ Main Parts Room temperature sensor Wi-Fi module Air intake (up and down) (left and right) Display Temperature indicator / Filter Reset indicator Defrost indicator Power consumption indicator / Auto clean indicator Power button/ Remote controller receiver Wi-Fi indicator Timer/ Auto clean indicator Samsung Electronics 9-1 9-2 Wireless Remote Control-Buttons and Display Remote controller buttons Vertical air swing blade movement automatically Power Mode Set one of the 5 operating modes conditioner Temp + Increase/Decrease the temperature by 1 ˚C. Options Fan Adjust the fan speed Horizontal air swing Select options during operation Timer Select Timer option blades movement automatically Settings Select settings SET Directional < > Move through the Timer, Options or Settings menu to make a selection Set/Cancel the selected option or setting t In case youwish to cancel the options or settings that you havejust set, press the Optionsor Settings button again, then the most recently selected item will blink and you may simply cancel it by pressing the SET button while selected item is blinking. 9-3 Samsung Electronics 10. Troubleshooting 10-1 Items to be checked first 1. The input voltage should be rating voltage ±10% range. The air conditioner may not operate properly if the voltage is out of this range. 2. Is the line cable linking the indoor unit and the outdoor unit linked properly? The indoor unit and the outdoor unit shall be linked by 5 cables. Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables. Otherwise the air conditioner may not operate properly. 3. When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the malfunction of the air conditioner. NO Operation of air conditioner Explanation 1 The OPERATION indication LED(BLUE) blinks when a power plug of the indoor unit is plugged in for first time. 2 In a COOL operation mode, the compressor does not operate at a room temperature higher than the setting In happens after a delay of 3 minutes when the compressor is reoperated. The same phenomenon occurs when temperature that the INDOOR FAN should operate. a power is on. As a phenomenon that the compressor is [ In case of heat pump model ] reoperated after a delay of 3 minutes, the indoor fan is In a HEAT operation mode, the compressor does not adjusted automatically with reference to a temperature of operate at a room temperature lower than the setting the air blew. temperature that indoor fan should operate. 3 Fan speed setting is not allowed in DRY 4 5 6 7 8 9 mode. It indicates power is on. The LED stops blinking if the operation ON/OFF button on the remote control unit is pushed. The speed of the indoor fan is set to LL in DRY mode. Fan speed is selected automatically in AUTO mode. Compressor operation is controlled automatically in DRY mode depending on the room temperature and humidity. Timer is being activated and the unit is in ready Timer LED(ORANGE) of the indoor unit lights up and mode. The unit operates normally if the timer operathe air conditioner does not operate. tion is cancelled. The compressor stops intermittently or the fan speed The compressor stops intermittently in a COOL of the indoor unit decreases to prevent inside/outside mode or DRY mode, and fan speed of the indoor unit air frozen depending on the inside/outside air temdecreases. perature. [In case of heat pump model] When the unit is turned off while de-ice is activated, Compressor of the outdoor unit is operating although the compressor continus operation for up to 9 minutes(maximum) until the deice is completed. it is turned off in a HEAT mode. The compressor and indoor fan stop intermittently if [In case of heat pump model] room temperature exceeds a setting temperature in The compressor and indoor fan stop intermittenly in order to protect the compressor from overheated air HEAT mode. in a HEAT mode. Compressor stops operation intermittently in Dry mode. [In case of heat pump model] Indoor fan and outdoor fan stop operation intermittently in a HEAT mode. Samsung Electronics The compressor operates in a reverse cycle to remove exterior ice in a HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heater operation. 10-1 10-2 Communication Error 10-2-1 Communication Error Indoor display 3-LED DISPLAY LED1 ◎ LED2 ● LED3 ● ● { ● ● ● ● 7-SEG DISPLAY DESCRIPTION E101/E102 Communication error(Indoor<->outdoor) Outdoor display ◎ { { OLED ON 1min. Time out Comm. Abnormal Communication ◎LED BLINKING {LED OFF 1. Checklist : 1) Is the cable between the indoor unit and outdoor unit connected correctly? 2) Isn't the power cable and communication cable cross? 2. Troubleshooting procedure Restart after power off. Is the communication error occurred again? NO Terminate the service. YES Is the connection of power cable and communication cable normal? NO Correct the wrong cable. YES Is the power is normal? (check the LED Lamp) NO Exchange the PBA of no power unit YES Exchange the indoor unit PBA. YES Is the communication error occurred again? NO Terminate the service. YES Exchange the outdoor unit PBA. 10-2 Samsung Electronics 10-2-2 Indoor temperature sensor Error Indoor display DESCRIPTION 7-SEG DISPLAY E121 Indoor room temp sensor error 1. Checklist : 1) Is the indoor units temperature sensor connected correctly? 2) Is the sensor placed correctly? 3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature? 2. Troubleshooting procedure Detach the assembled sensor from the PBA sensor connector and measure the sensor resistance with ohmmeter(tester) Is the sensor resistance value 10kohm±3% at the room temperature of 25°C NO YES Ass'y Sensor Replace Sensor resistance value : 20°C- 12.09kohm 30°C - 8.31kohm 35°C - 6.94kohm 40°C- 5.83kohm Connect the sensor to PBA connector (6piin) Is the connection ofthe power cableof #1-#2 in supply power and measure voltage and communication cable normal? the connector Below 0.5V or Over 4.5V? YES Exchange the indoor PBA NO Micom error or connector check YES Exchange the indoor PBA Samsung Electronics 10-3 10-2-3 Indoor Eva-in temperature sensor error Indoor display 3-LED DISPLAY LED1 ◎ OLED ON LED2 ◎ LED3 { 7-SEG DISPLAY DESCRIPTION E122,E123 Indoor MID, Indoor IN PIPE-TH sensor error ◎LED BLINKING {LED OFF 1. Checklist : 1) Is the indoor units temperature sensor connected correctly? 2) Is the sensor placed correctly? 3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature? 2. Troubleshooting procedure Detach the assembled sensor from the PBA sensor connector and measure the sensor resistance with ohmmeter(tester) Is the sensor resistance value #3-#4 and #5-#6 10kohm±3% at the room temperature of 25ఁ NO YES Sensor Replace Sensor resistance value : 20°C- 12.09kohm 30°C - 8.31kohm 35°C - 6.94kohm 40°C- 5.83kohm Connect the sensor to PBA connector (6piin) Is the connection of power cableof #3-#4 supply power and measure the voltage and and communication cable normal? #5-#6 in the connector Below 0.5V or Over 4.5V? YES Exchange the indoor PBA NO Micom error or connector check YES Exchange the indoor PBA 10-4 Samsung Electronics 10-2-4 When the Up/Down, Left/Right, Grill louver motor does not operate (Initial Diagnosis) (Not displayed) 1. Checklist : 1) Is the input power voltage normal? 2) Is the Up/Down louver motor properly connected with the connector? (CN61, CN62, CN63) 2. Troubleshooting procedure Unplug the power cord and plug it after 30seconds later. Is the lamp blinking? NO Check the as in the procedure. No power. NO Connect the wire PBA to louver motor YES Is the connected louver wire? YES Does operation start when swing button of the remote control unit pushed? YES Normal NO Is the voltage changeable at the pin#2~#5 of CN61, CN62, CN63 (louver connector)? NO Exchange the PBA YES Up/Down louver motor is faulty. Samsung Electronics 10-5 10-2-5 Indoor fan motor speed detecting error (BLDC fan) Indoor display 3-LED DISPLAY LED1 { OLED ON LED2 { 7-SEG DISPLAY DESCRIPTION E154 Indoor fan error LED3 ◎ ◎LED BLINKING {LED OFF 1. Checklist : 1) Is the indoor units fan motor properly connected with the connector(CN72)? 2) Is the AC voltage correct? 2. Troubleshooting procedure Restart after power off. NO Does the fan rotate? Power off and Separate the Fan motor wire from CN72 on Indoor PBA YES Is there short among each pin #1~#6 Reassemble the fan wire and input the power again YES Exchange the Fan motor NO Is the fan error appeared again? NO Terminate the service NO Follow the check procedure of Indoor unit power supply error check NO Exchange the Indoor PBA YES Is the voltage of CN72 #1-#3 over 250Vdc YES Is the voltage of CN72 #3-#5 and #3-#6 with in 1Vdc~15Vdc during the operation? YES PBA problem or Motor problem Change the PBA first and check the operation Exchange the Fan motor 10-6 Samsung Electronics 10-2-6 Outdoor temperature sensor error Indoor display 3-LED DISPLAY LED1 7-SEG DISPLAY LED2 LED3 E221 DESCRIPTION Outdoor temperature sensor error Outdoor display Outdoor temperature sensor error LED ON LED BLINKING LED OFF 1. Checklist : 1) Is the sensor connected correctly? 2) Is the sensor placed correctly? 3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature? 4) Is the resistance value of sensor connection pull-up correct? MODEL ALL "A" CN251 "B" CN251 #1-#2 2. Troubleshooting procedure Is the sensor connector("A") connected correctly in accordance with a color? NO Reconnect the sensor connector. YES Is the sensor resistance value "B" 10kohm±3% at the room temperature of 25 NO YES Sensor Replace Sensor resistance value :20 - 12.09kohm 30 - 8.31kohm 35 - 6.94kohm 40 - 5.83kkohm Connect the sensor to PBA connector Is the connection of power supply power and measure the cable voltage of "B"in the connector and communication cable normal? Below 0.5Vdc or Over 4.5Vdc? YES Exchange the Outdoor PBA NO Micom error or connector check YES Exchange the Outdoor PBA Samsung Electronics 10-7 10-2-7 Outdoor Cond temperature sensor error Indoor display 3-LED DISPLAY LED1 DESCRIPTION 7-SEG DISPLAY LED2 LED3 E231 Outdoor Cond temperature sensor error Outdoor display Outdoor Cond temperature sensor error LED ON LED BLINKING LED OFF 1. Checklist : 1) Is the sensor connected correctly? 2) Is the sensor placed correctly? 3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature? 4) Is the resistance value of sensor connection pull-up correct? ALL MODEL CN251 "A" CN251 #5-#6 "B" 2. Troubleshooting procedure Is the sensor connector("A") connected correctly in accordance with a color? NO Reconnect the sensor connector. YES Is the sensor resistance value "B" 10kohm±3% at the room temperature of 25 NO YES Sensor Replace Sensor resistance value 20 - 12.09kohm 30 - 8.31kohm 35 - 6.94kohm 40 - 5.83kohm Connect the sensor to PBA connector Is the and connection power cableof "B" supply power measureof the voltage in the connector and communication cable normal? Below 0.5Vdc or Over 4.5Vdc? YES Exchange the Outdoor PBA NO Micom error or connector check YES Exchange the Outdoor PBA 10-8 Samsung Electronics 10-2-8 Outdoor Discharge temperature sensor error Indoor display 3-LED DISPLAY LED1 LED2 LED3 7-SEG DISPLAY DESCRIPTION E251 Outdoor Discharge temperature sensor error Outdoor display Outdoor Discharge temperature sensor error LED ON LED BLINKING LED OFF 1. Checklist : 1) Is the sensor connected correctly? 2) Is the sensor placed correctly? 3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature? 4) Is the resistance value of sensor connection pull-up correct? MODEL ALL CN251 "A" CN251 #3-#4 "B" 2. Troubleshooting procedure Is the sensor connector("A") connected correctly in accordance with a color? NO Reconnect the sensor connector. YES Is the sensor resistance value "B" 200kohm±3% at the room temperature of 25 NO YES Sensor Replace Sensor resistance value 20 - 242kohm 30 - 166ohm 35 - 138ohm 40 - 115kohm Connect the sensor to PBA connector Is the and connection power cableof supply power measureof the voltage "B"in the andconnector communication cable normal? Below 0.5Vdc or Over 4.5Vdc? YES Exchange the Outdoor PBA NO Micom error or connector check YES Exchange the Outdoor PBA Samsung Electronics 10-9 10-2-9 Outdoor Discharge over temperature error Indoor display 3-LED DISPLAY LED1 LED2 7-SEG DISPLAY LED3 E416 DESCRIPTION Outdoor Discharge ove temperature error Outdoor display Outdoor Discharge over temperature error LED ON LED BLINKING LED OFF 1. Checklist : 1) Check the discharge temperature in the outdoor unit 2) Check the compressor locking or gas leak 3) Download the EEPROM data 2. Troubleshooting procedure Restart after power off. after 30min ~ 1Hr Is the discharge over temperature sensor error appeared again? NO Terminate the service YES The condition is too poor for air conditioner to operate . Wait until discharge temperature is decreased Restart after power off Is the discharge over temperature sensor error appeared again? NO Terminate the service YES Download the EEPROM data Is the discharge over temperature sensor error appeared again? NO Terminate the service YES Exchange the Outdoor PBA Exchanged the Compressor 10-10 Samsung Electronics 10-2-10 Outdoor Fan motor error Indoor display 3-LED DISPLAY LED1 LED2 7-SEG DISPLAY DESCRIPTION E458 Outdoor fan error LED3 Outdoor display Outdoor fan error LED ON LED BLINKING LED OFF 1. Checklist : 1) Are the input power voltage and the power connection correct? 2) Is the motor wire connected to the outdoor PBA correctly? 3) Is there no assembly error or non-assembly in the terminal of motor wire connector? 4) Is there no obstacle at the surrounding of motor and propeller? 2. Troubleshooting procedure MODEL ALL "A" CN901 Restart after power off. NO Does the fan rotate? Power off and Separate the Fan motor wire from "A" on Outdoor PBA YES Is there short among each pin #1~#6 Reassemble the fan wire and input the power again YES Exchange the Fan motor NO Is the fan error appeared again? NO Terminate the service NO Follow the check procedure of outdoor unit power supply error check NO Exchange the Outdoor PBA YES Is the voltage of "A" #1-#3 over 250Vdc YES Is the voltage of "A" #3-#5 and #3-#6 with in 1Vdc~15Vdc during the operation? YES PBA problem or Motor problem Change the PBA first and check the operation Exchange the Fan motor Samsung Electronics 10-11 10-2-11 Compressor starting error Indoor display 3-LED DISPLAY LED1 LED2 LED3 7-SEG DISPLAY DESCRIPTION E461 Comp starting error Outdoor display Comp starting error LED ON LED BLINKING LED OFF 1. Checklist : 1) Is the connection of cable for the compressor? 2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL) 3) Is the interphase resistance of compressor normal? 2. Troubleshooting procedure Restart after power off. Is the restart error occurred again? NO Terminate the service YES Is the connection of compressor wire is normal? NO Connect the comp wire normally YES Download the EEPROM data Is the restart error occurred again? NO Terminate the service YES Is the compressor body and interphase resistance insulated? NO Exchange the Outdoor PBA YES Exchange the compressor 10-12 Samsung Electronics 10-2-12 Compressor wire missing error/rotation error Indoor display 3-LED DISPLAY LED1 ◎ LED2 { LED3 ◎ { O 7-SEG DISPLAY DESCRIPTION E467 Compressor wire missing errorr/rotation error Outdoor display O OLED ON ◎LED BLINKING Compressor wire missing error/rotation error {LED OFF 1. Checklist : 1) Is the connection of cable for the compressor? 2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL) 3) Is the interphase resistance of compressor normal? 2. Troubleshooting procedure Restart after power off. Is the restart error occurred again? NO Terminate the service YES Is the connection of compressor wire is normal? (PBA and Compressor) NO Connect the comp wire normally YES Is the restart error occurred again? NO Terminate the service YES Is the compressor body and interphase resistance insulated? NO Exchange the Outdoor PBA YES Exchange the compressor Samsung Electronics 10-13 10-2-13 O.C(Over Current) error Indoor display 3-LED DISPLAY LED1 ◎ LED2 { LED3 ◎ { ◎ 7-SEG DISPLAY DESCRIPTION E464 IPM Over Current(O.C) Error Outdoor display { OLED ON ◎LED BLINKING IPM Over Current(O.C) Error {LED OFF 1. Checklist : 1) Is the IPM Shunt resistance value correct? Check the resistor is opened 2) Is the condition of surrounding temperature abnormal overload? 3) Is there any problem as like the temperature sensor separation or measurement value error? 4) Is the interphase resistance of compressor normal? 2. Troubleshooting procedure Restart after power off. Is the O.C error occurred? NO Terminate the service YES Is the connection of compressor wire is normal? NO Connect the comp wire normally YES Is the O.C error occurred again? NO Terminate the service YES Is the condition of indoor/outdoor temperature normal load? NO Restart after returning to the normal load YES Is the O.C error occurred again? 10-14 Terminate the service Samsung Electronics Is the position of temperature sensor and sensing value normal? Is the compressor body and interphase resistance insulated? NO NO Correct the sensor position or exchange the sensor Exchange the Outdoor PBA YES Exchange the compressor Samsung Electronics 10-15 10-2-14 DC_link voltage sensor error Indoor display 3-LED DISPLAY LED1 DESCRIPTION 7-SEG DISPLAY LED2 LED3 E469 DC_link voltage sensor error Outdoor display DC_link voltage sensor error LED ON LED BLINKING 1. Checklist : 1) Is the 2) Is the 3) Is the 4) Is the LED OFF input voltage of outdoor terminal block is normal? reactor wire connected? DC_link capacitor("A") assembled in accordance the specification? (Outdoor PBA) DC_link resistor("B") value is normal? (Outdoor PBA) 2. Troubleshooting procedure MODEL DB92-02866A DB92-02867A Is the connected of reactor wire? (PBA-Reactor) "A" CE101,CE102,CE103 CE053,CE054,CE055,CE056 NO Connect the reactor wire NO Check the power input NO Exchange the Outdoor PBA NO Exchange the Outdoor PBA "B" R101 R062 YES Restart after power off. Start the operation (cooling mode or heating mode) Is the DC_link voltage ("A") is normal in operation mode? Normal range(280Vdc~320Vdc) YES Is the DC_link sensing voltage("B") is normal in operation mode? Normal range (0.2Vdc~4.8Vdc) YES Is the reactor insulation damaged? YES Exchange the Reactor 10-16 Samsung Electronics 10-2-15 DC_link voltage sensor error Indoor display 3-LED DISPLAY LED1 DESCRIPTION 7-SEG DISPLAY LED2 LED3 E488 AC Input Voltage Sensor Error Outdoor display AC Input Voltage Sensor Error LED ON LED BLINKING LED OFF 1. Checklist : 1) Is the input voltage of outdoor terminal block is normal? 2) Is the reactor wire connected? 3) Is the PFC resistor("A") value is normal? (Outdoor PBA) 2. Troubleshooting procedure MODEL "A" DB92-02866A/2867A R105,R106,R107,R108 Is the connected of reactor wire? (PBA-Reactor) NO Connect the reactor wire NO Exchange the Outdoor PBA NO Exchange the Outdoor PBA "B" R105 YES Restart after power off. Start the operation (cooling mode or heating mode) Is the DC_link sensing voltage("B") is normal in operation mode? Normal range (0.2Vdc~4.8Vdc) YES Is the reactor insulation damaged? YES Exchange the Reactor Samsung Electronics 10-17 10-2-16 DC_link voltage under/over error, H/W DC-link Over voltage protection error/PFC over load Indoor display 3-LED DISPLAY LED1 DESCRIPTION 7-SEG DISPLAY LED2 LED3 E466 DC-Link voltage under/over error E483 E484 Over Voltage Protection Error PFC over load Outdoor display DC-Link voltage under/over error PFC over load Over Voltage Protection Erro LED ON LED BLINKING 1. Checklist : 1) Is the 2) Is the 3) Is the 4) Is the 5) Is the 6) Is the LED OFF input voltage of outdoor terminal block is normal? input voltage is higher than 300Vac? reactor wire connected? DC_link capacitor(A") assembled in accordance the specification? (Outdoor PBA) DC_link resistor("B") value is normal? (Outdoor PBA) MODEL "A" PFC resistor("C") value is normal? (Outdoor PBA) DB92-02866A CE101,CE102,CE103 DB92-02867A CE053,CE054,CE055,CE056 "B" R101,R102,R103,R104 R059,R060,R061,R062 2. Troubleshooting procedure MODEL DB92-02866A/2867A Is the connected of reactor wire? (PBA-Reactor) "C" R105,R106,R107,R108 NO Connect the reactor wire NO Check the input power in the powercord. NO Check the input power "D" R105 YES Restart after power off. Is the the input voltage is nomal? Normal range(180Vac ~ 270Vac) YES Restart after power off. Start the operation (cooling mode or heating mode) Is the DC_link voltage ("A") is normal in operation mode? Normal range(280Vdc~320Vdc) YES 10-18 Samsung Electronics Is the DC_link sensing voltage("D")is normal in operation mode? Normal range (0.2Vdc~4.0Vdc) NO Exchange the Outdoor PBA NO Exchange the Outdoor PBA YES Is the reactor insulation damaged? YES Exchange the Reactor Samsung Electronics 10-19 10-2-17 I_trip error, PFC over current Indoor display 3-LED DISPLAY LED1 LED2 DESCRIPTION 7-SEG DISPLAY LED3 E462 AC Input I_Limit Trip Error Outdoor display AC Input I_Limit Trip Error LED ON LED BLINKING LED OFF 1. Checklist : 1) Is the PFC Shunt("A") resistance value correct? Check the resistor is opened 2) Is the condition of surrounding temperature abnormal overload? 3) Is there any problem as like the tempera ture sensor separation or measurement value error? 4) Is the interphase resistance of compressor normal? 2. Troubleshooting procedure MODEL DB92-02866A DB92-02867A "A" R410,R411,R412 R408,R409,R410 Restart after power off. Is the condition ofi ndoor/outdoor temperature normal load? NO YES Restart after returning to the normal load Is the I_trip error occurred again? NO Terminate the service YES Is the position of temperature sensor and the sensing value normal? NO Correct the sensor position or exchange the sensor YES Is the connection cable for the compressor and power terminal normal? NO Correct the cable connection YES Exchange the Outdoor PBA 10-20 Samsung Electronics 10-2-18 Current sensor error/Input current sensor error Indoor display 3-LED DISPLAY LED1 LED2 LED3 DESCRIPTION 7-SEG DISPLAY E462 AC Input I_Limit Trip Error Outdoor display Current sensor error Input current sensor error LED ON LED BLINKING LED OFF 1. Checklist : 1) Is the PFC Shunt("A") resistance value correct? Check the resistor is opened 2) Is the IPM Shunt("B") resistance value correct? Check the resistor is opened 3) Is there no short or open around "C"? 2. Troubleshooting procedure Restart after power off. Is the PFC shunt and IPM shunt resistance value correct? MODEL DB92-02866A DB92-02867A NO "A" R426,R425 R063,R064,R065 "B" R410,R411,R412 R408,R409,R410 "C" IC451 IC451 Exchange the Outdoor PBA YES Is the current sensor error appeared again? NO Terminate the service YES Exchange the Outdoor PBA Samsung Electronics 10-21 10-2-19 Heatsink sensor error/Heatsink over heat Indoor display 3-LED DISPLAY LED1 LED2 LED3 ◎ { ◎ 7-SEG DISPLAY DESCRIPTION E474 E500 Heatsink sensor error Heatsink Over Temperature Error Outdoor display ◎ ◎ O Heatsink sensor error ◎ O { Heatsink Over Temperature Error OLED ON ◎LED BLINKING {LED OFF 1. Checklist : 1) Are there screws assembly in PBA-heatsink? 2) Is the gap PBA-heatsink 3) Is the fan operation normal? 4) Is the cover assembly in control-box normal? 2. Troubleshooting procedure Restart after power off. Are there screws in PBA-heatsink? (4 screws) NO Fastening the screw YES Is the fan operation normal? NO Check the fan connection Change the Fan motor YES Exchange the Outdoor PBA 10-22 Samsung Electronics 10-2-20 Comp Vlimit error Indoor display 3-LED DISPLAY LED1 LED2 LED3 7-SEG DISPLAY DESCRIPTION E465 Comp V_limit/I_limit Error Outdoor display Comp V_limit/I_limit Error LED ON LED BLINKING LED OFF 1. Checklist : 1) Is the IPM Shunt("A") resistance value correct? Check the resistor is opened 2) Is the condition of surrounding temperature abnormal overload? 3) Is there any problem as like the temperature sensor separation or measurement value error? 4) Is the interphase resistance of compressor normal? 2. Troubleshooting procedure MODEL DB92-02866A DB92-02867A "A" R410,R411,R412 R408,R409,R410 Restart after power off. Is the O.C error occurred? NO Terminate the service NO Connect the comp wire normally NO Terminate the service NO Restart after returning to the normal load YES Is the connection of compressor wire is normal? YES Is the Comp Vlimit error occurred again? YES Is the condition of indoor/outdoor temperature normal load? YES YES Samsung Electronics Is the O.C error occurred again? NO Terminate the service 10-23 Is the position of temperature sensor and sensing value normal? NO Correct the sensor position or exchange the sensor YES Exchange the Outdoor PBA YES Is the compressor body and interphase resistance insulated? NO Exchange the compressor 10-24 Samsung Electronics 10-2-21 EEPROM error/OTP error Indoor display 3-LED DISPLAY LED1 LED2 LED3 DESCRIPTION 7-SEG DISPLAY E470 Ƽ Ƽ EEPROM Data Error (no data) OTP errorEEPROM Data Error (Main Micom Inv Micom) E471 Outdoor display Ƽ LED ON Ƽ LED BLINKING EEPROM Data Error (no data) OTP errorEEPROM Data Error (Main MicomInv Micom) LED OFF 1. Checklist : 1) Is there a short around micom? 2) Is there a short around "A"? 3) Did you download or insert EEPROM IC, after changing outdoor PBA? 2. Troubleshooting procedure MODEL DB92-02866A DB92-02867A "A" CN501 CN202 power off and download EEPROM data (or. Insert the service EEPROM IC) Restart after power off Is the error appeared again? NO Terminate the service YES Exchange the Outdoor PBA Samsung Electronics 10-25 10-2-22 Operation condition secession error Indoor display 3-LED DISPLAY LED1 LED2 LED3 7-SEG DISPLAY E440 ◎ ◎ { E441 DESCRIPTION Prohibit Operation Condition Error (Heating) Prohibit Operation Condition Error (Cooling) Outdoor display O OLED ON ◎ Operation condition secession { ◎LED BLINKING {LED OFF 1. Checklist : 1) Check the temperature around the outdoor unit. 2. Troubleshooting procedure Restart after power off Is the operation condition secession error appeared again? NO Terminate the service YES * Heating mode * Is the outdoor temperature over 40ఁ or under -30ఁ? * Cooling mode * Is the outdoor temperature under -7ఁ YES The temperature condition is too poor to operate. Wait until temperature is changed 10-26 Samsung Electronics 10-2-23 Gas leak error Indoor display 3-LED DISPLAY LED1 LED2 LED3 7-SEG DISPLAY DESCRIPTION E554 GAS Leak error Outdoor display GAS Leak error LED ON 1. Checklist : 1) Is the 2) Check 3) Check 4) Check LED BLINKING LED OFF position ofi ndoor Eva_in sensor normal? the pipe crack the EEV valve connection("A") in Outdoor unit the refrigerant was charged MODEL DB92-02866A DB92-02867A 2. Troubleshooting procedure Is the position ofi ndoor eva _in sensor normal? NO "A" CN701 CN701 Indoor sensor take the normal position YES Restart after power off after 20minutes later Is the gas leak error appeared again? NO Terminate the service. YES Check the EEV valve operation. Is the EEV valve connection normal? NO Connect the EEV valve. YES Is the EEV valve is operation? Check the sound of EEV valve after power on. NO Change the EEV valve. YES Samsung Electronics 10-27 Is the pressure of refrigerant normal? NO Check the pipe crack. Fill up the refrigerant. YES Exchange the Indoor PBA Exchange the Outdoor PBA 10-28 Samsung Electronics 102-24 No power outdoor (Initial Diagnosis) (Not displayed) 1. Checklist : 1) Is input power normal? 2) Is AC power linked correctly? (L,N,E) 3) Is mis-wiring between communication wire and Power wire? 4) Is mis-wiring between Main PBA and SMPS PBA wire? 5) Is input voltage of SMPS AC in Main PBA (CN150) normal? 6) Is the voltage of SMPS DC in Main PBA (CN151,CN152) normal? 2. Troubleshooting procedure MODEL ALL Unplug the power cord Is the power cable from terminal block to PBA is correct?L :CN002, N:CN001, EARTH:CN003 NO Reconnect the power wire correctly. YES Check the fuse open or not? (F001) NO Exchange the Main PBA YES Restart after power off. Is the power normal? NO Check the power source. YES Is AC power is normal for SMPS? CN150 : 220Vac~240Vac NO Exchange the Main PBA YES Check SMPS wire connection Samsung Electronics 10-29 After seperate SMPS DC wire (3PIN RED, 3PIN BLU) from Main PBA Connector CN151, CN152, Check the DC voltage in SMPS PBA. Is the voltage is normal in SMPS PBA? (SMPS : CN002, CN003 Check) NO Exchange the SMPS PBA YES After connect SMPS DC wire (3PIN RED, 3PIN BLU) with Main PBA Connector CN151, CN152, Check the DC voltage in Main PBA. Is the voltage is normal in Main PBA? (Main : CN151,CN152 Check) NO Exchange the Main PBA YES Exchange the Main PBA, SMPS PBA 10-30 Samsung Electronics 10-2-25 No power outdoor (Initial Diagnosis) (Not displayed) 1. Checklist : 1) Is input power normal? 2) Is AC power linked correctly? (L,N,E) 3) Is mis-wiring between communication wire and Power wire? 4) Is input voltage of SMPS DC-link capacitor("A") normal? 5) Is the voltage of SMPS DC normal? 2. Troubleshooting procedure Unplug the power cord Is the power cable from terminal block to PBA is correct?L :"B", N:"C", EARTH:"D" MODEL DB92-02867A DB92-02866A "A" CE101 CE101 MODEL DB92-02867A DB92-02866A "E" F001 F001 "B" CN002 CN002 "F" CN153:#1 3 CN151:#1 3 NO Reconnect the power wire correctly. NO Exchange the PBA NO Check the power source. NO Exchange the SMPS PBA NO Exchange the SMPS PBA "C" CN001 CN001 "D" CN003 CN003 "G" "H" CN152#1 2 CN152#2 3 CN152#1 2 CN152#2 3 YES Check the fuse open or not? ("E") YES Restart after power off. Is the power normal? YES Is the SMPS is normal? "G" Main 15V : 14Vdc ~ 15Vdc YES Is the SMPS is normal? "G" Main 12V : 11Vdc ~ 13Vdc YES Is the SMPS is normal? "H" Main 5V : 4.5Vdc ~ 5.5Vdc NO Exchange the SMPS PBA YES Exchange the PBA Samsung Electronics 10-31 10-2-26 AC zero cross signal error Indoor display 3-LED DISPLAY LED1 LED2 LED3 DESCRIPTION 7-SEG DISPLAY E472 AC zero cross signal error Outdoor display AC zero cross signal error LED ON LED BLINKING LED OFF 1. Checklist : 1) Check the power condition at customer's house (Is there any power noise?) 2) Have been there power failure? 2. Troubleshooting procedure MODEL DB92-02866A/2867A Error display O Restart after power off Is the AC line zero cross signal error appeared again? NO Terminate the service YES Exchange the Outdoor PBA 10-32 Samsung Electronics 10-2-27 AC zero cross signal error Indoor display 3-LED DISPLAY LED1 LED2 LED3 7-SEG DISPLAY E556 DESCRIPTION Capacity miss match error Outdoor display Capacity miss match error LED ON LED BLINKING LED OFF 1. Checklist : 1) Check the Btu between indoor and outdoor unit 2) Check the indoor unit option and outdoor unit EEPROM data MODEL DB92-02866A/2867A 2. Troubleshooting procedure Is the rated Btu between indoor unit and outdoor unit? NO Error display O Exchange the one of them according to the exact model spec YES Reset the option code again at indoor unit Is the capacity miss match error appeared again? NO Terminate the service YES Download the EEPROM data Is the capacity miss match error appeared again? NO Terminate the service YES Exchange the Outdoor PBA Exchange the Indoor PBA Samsung Electronics 10-33 10-2-28 When the remote control is not receiving 1. Checklist : 1) Check if the connector was normally assembled. 2) Check the battery in remote control 3) All the lights out and check again : Change electronic typed to a fluorescent light 4) Put the set in operation and check the voltage of display PBA 5) Replace the display PBA 10-34 Samsung Electronics 10-2-29 EEV or Valve Close error-Self diagnosis Indoor display 3-LED DISPLAY LED1 LED2 LED3 7-SEG DISPLAY E422 DESCRIPTION EEV or Valve Close error-Self diagnosis Outdoor display EEV or Valve Close error-Self diagnosis LED ON LED BLINKING 1. Checklist : 1) Is the 2) Check 3) Check 4) Check LED OFF position ofi ndoor Eva_in sensor normal? the pipe crack the EEV valve connection("A") in Outdoor unit the refrigerant was charged MODEL DB92-02866A/2867A "A" CN701 2. Troubleshooting procedure Is the position ofi ndoor eva_in sensor normal? NO Indoor sensor take the normal position YES Restart after power off after 20minutes later Is the gas leak error appeared again? NO Terminate the service. YES Check the EEV valve operation. Is the EEV valve connection normal? NO Connect the EEV valve. YES Is the EEV valve is operation? Check the sound of EEV valve after power on. NO Change the EEV valve. YES Is the pressure of refrigerant normal? NO Check the pipe crack. Fill up the refrigerant. YES Exchange the Indoor PBA Exchange the Outdoor PBA Samsung Electronics 10-35 10-2-30 10-3-18 Smart Install error 1. Checklist : 1) Check the leakage region.(Use leakage detection liquid or soapy water) 2) When leakage region is found from service valve and piping connection flare nut part : After the related measures to check the refrigerant supplements and operation. 3) If the leakage region is pipe welding part : Weld leakage region after refrigerant gas release.(Brass parts should only apply) 4) If the leakage region is surface area (Heat exchanger or pipe welding region is not) : Replace parts. 5) Check the PBA Relay - Display of indoor unit : Ensure that the operating pilot lamp has been lighted. - Ensure that the Relay input voltage of indoor unit PBA is normally.(If the PBA is defective, replace) 2. Troubleshooting procedure Did stop valve of the low pressure valve open perfectly? NO Open perfectly stop valve. (Use the 4mm hex wrench) YES Re-connect after 3 seconds, after separate the power cord. And then begin cooling operation with minimum temperature that can establish. (use the remote control) YES Among compressor operation, does cold air come out from the indoor unit? YES NO Connect the manifold gauge to the service port of low pressure side service valve and then measure the refrigerant pressure. YES Does measurement pressure include in ±10% extent of reference pressure? NO YES - Discharge temperature and the indoor temperature measurements confirm that the difference is more than 10ఁ. - Fill up perfectly refrigerant after re-vacuum. [Execute the troubleshooting] Check the refrigerant leaks. Check the PCB Relay. YES YES Execute the related troubleshooting. End 10-36 Samsung Electronics 10-3 PCB Inspection Method 10-3-1 Pre-inspection Notices 1. 2. 3. 4. Check if you pulled out the AC power plug when you eliminate the PCB or front panel. Don't hold the PCB side not impose excessive force on it to eliminate the PCB. Don’t pull the lead wire but hold the whole housing to connect or disconnect a connector to the PCB. In case of outdoor PCB disassembly, check first the complete discharge of condenser after 1 minute power off. 10-3-2 Inspection procedure 1. Check connector connection and peeling of PCB or bronze coating pattern when you think the PCB is broken. 2. The PCB is composed of 3 parts. . Indoor Main part : MICOM and surrounding circuit, relay, fan motor sensing and driving circuit, temperature sensing circuit power circuit of SMPS, buzzer circuit. Communication circuit. . Display part : LED lamp, Switch, Remote-control module. . Outdoor Main part : MICOM and surround circuit, fan motor sensing and driving circuit, compressor driving circuit power circuit of SMPS, PFC control circuit, 4way circuit, communication circuit, OPTION.(EEV control circuit, temperature sensing circuit) 10-3-3 Indoor detailed inspection procedure No 1 procedure Plug out and pull the PCB out of the control box Check the PCB fuse. Inspection Method 1) Is 1st fuse disconnected? 2) Is 2nd fuse disconnected? Cause . Over current. . Indoor Fan motor short. . AC part and pattern short of Indoor PBA. Check the power voltage 2 Supply power If the operating lamp twinkles at this time , the above 1)~3) have no relation. 1) Is the BD71 input voltage 200Vac ~240Vac? . Power cord is fault, Fuse open, Wrong Power cable Wiring, AC part is faulty. 2) Is the voltage between both terminal of C111(+)-(-) 12Vdc? . Switching Trans of Power circuit is faulty. 3) Is the voltage between both terminal of C118(+)-(-) 5Vdc? . Power circuit is faulty, Load short. 1) Is the voltage over DC 270V being imposed on terminal #1~#3 of . Fan motor of the indoor is faulty. fanmotor connector(CN72)? 3 Press the ON/OFF button. 1. Fan speed(high) 2. Continuous Operation Samsung Electronics 2) The fan motor of the indoor unit doesn't run. . Fan motor connector(CN72) is faulty. 3) The power voltage between terminal #1-#3 of the connector(CN72) is 0V. . PBA is faulty. 10-37 㽞 New Function [ Indoor Terminal Block Safety Device ] 1. Thermal Fuse is installed in Terminal Block as below. (Thermal Fuse is used to prevent PL caused by a defective connection of indoor and outdoor units) Thermal Fuse Connection of terminal block and Main PBA Terminal Block Internals 2. Thermal Fuse is opened when internal temperature of Terminal Block goes to a certain point due to Tracking caused by a defective connection of indoor and outdoor units. - When Thermal Fuse is opened, Main PBA (DC12V) is turned off and the indoor unit does not operate. (There is no problem with Main PBA in this case) - In the above case, the change of all-in-one Terminal Block will make Main PBA operate again. Circuit Block 3. Measurement method of fair/defective thermal fuse Fail 10-38 Defective Samsung Electronics 11. Block Diagram 11-1 Indoor unit CONTROLLER IC-MCU HEAT EXCHANGER SENSOR ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ROOM TEMPERATURE SENSOR HUMIDITY SENSOR INFRARED SIGNAL REMOTE CONTROL DISPLAY PART H/V BLADE CONTROL INDOOR FAN MOTOR CONTROL OUTDOOR COMMUNICATION TEMPERATURE CONTROL HUMIDITY CONTROL TIMER BUZZER CONTROL WIFI MODEM COMMUNICATION DISPLAY CONTROL SPI OSCILLATION CIRCUIT ・ DISPLAY - TIMER - GOODSLEEP - COMFORT CARE - 88 SEGMENT ・ SPI ZERO VOLTAGE DETECT POWER ON/OFF PWM CONTROL SIGNAL MODE (AUTO,COOL,DRY,FAN, HEAT) SPI SELECT SMART SAVER SELECT TURBO OPERATION ・ STEPPING MOTOR CONTROL SIGNAL ・ SPI CONTROL SIGNAL ・ BUZZZER CONTROL SIGNAL PHOTO COUPLER INDOOR FAN MOTOR OVER VOLTAGE PROTECTION QUIET OPERATION TEMPERATURE SELECT(UP/DOWN) WI-FI MODEM FAN SPEED SELECT (H/M/L/AUTO) COMMUNICATION SIGNAL BLADE-H/V MOVING SELECT OUTDOOR UNIT d'LIGHT COOL SELECT BUZZER AUTO CLEAN SELECT GOOD SLEEP SELECT ON,OFF TIMER SELECT(UP/DOWN) ・ STEPPING MOTOR DRIVE ・ SPI DRIVE ・ BUZZER DRIVE SPI ・ STEPPING MOTOR - BLDAE CONTROL(H/V) TEMP/HUMI SELECT BEEP ON/OFF SELECT DISPLAY ON/OFF SELECT DC12V DC5V SMPS POWER BLOCK WPS MODE SELECT DC5V AP MODE SELECT DC12V DC15V AC INPUT Samsung Electronics AC230V 11-1 11-2 Outdoor unit 11-2 Samsung Electronics 11-2-1 Pre-inspection Notices 1. Check if you pulled out the AC power plug when you eliminate the PCB or front panel 2. Don't hold the PCB side not impose excessive force on it to eliminate the PCB 3. Don’t pull the lead wire but hold the whole housing to connect or disconnect a connector to the PCB 4. In case of outdoor PCB disassembly, check first the complete discharge of condenser after 1 minute power off 11-2-2 Inspection procedure 1. Check connector connection and peeling of PCB or bronze coating pattern when you think the PCB is broken 2. The PCB is composed of 3 parts • Indoor Main part : MICOM and surrounding circuit, relay, fan motor sensing and driving circuit, temperature sensing circuit power circuit of SMPS, buzzer circuit. Communication circuit • Display part : LED lamp, Switch, Remote-control module • Outdoor Main part : MICOM and surround circuit, fan motor sensing and driving circuit, compressor driving circuit power circuit of SMPS, PFC control circuit, 4way circuit, communication circuit, OPTION (EEV control circuit, temperature sensing circuit) 11-2-3 Indoor detailed inspection procedure No 1 Procedure Plug out and pull the PCB out of the control box Check the PCB fuse Inspection Method 1) Is 1st fuse disconnected? 2) Is 2nd fuse disconnected? Cause . Over current . Indoor Fan motor short . AC part and pattern short of Indoor PBA Check the power voltage 2 3 Supply power If the operating lamp twinkles at this time , the above 1)~3) have no relation Press the ON/OFF button 1. Fan speed(high) 2. Continuous Operation Samsung Electronics 1) Is the BD71 input voltage 200Vac~240Vac? . Power cord is fault, Fuse open, Wrong Power cable Wiring, AC part is faulty 2) Is the voltage between both terminal of IC02 pin #1-#2 12Vdc? . Switching Trans of Power circuit is faulty 3) Is the voltage between both terminal of IC02 pin #2-#3 5Vdc? . Power circuit is faulty, Load short 1) Is the voltage over AC 180V being imposed on terminal #3-#5 of fan motor connector (CN72)? . Fan motor of the indoor is faulty 2) The fan motor of the indoor unit doesn't run . Fan motor connector(CN72) is faulty 3) The power voltage between terminal #3-#5 of the connector(CN72) is 0V . PBA is faulty 11-3 2XWGRRUGHWDLOHGLQVSHFWLRQSURFHGXUH 1R SURFHGXUH ,QVSHFWLRQ0HWKRG 3OXJRXWDQGSXOOWKH3&%RXWRI ,VVWIXVHGLVFRQQHFWHG" WKHFRQWUROER[ ,VLQGRRU3%$IDXOW\" &KHFNWKH3&%IXVH :DLWPLQXWHVDIWHUSRZHURII &KHFNWKH:LULQJ ,VWKH&RPSUHVVRUZLUHFRQQHFWHG FORFNZLVH" ,VWKH5HDFWRUZLUHFRQQHFWHG QRUPDO" ,VWKH)DQZLUHFRQQHFWHGQRUPDO" ,VWKHZD\ZLUHFRQQHFWHGQRUPDO" ,VWKHVHQVRUZLUHFRQQHFWHG &KHFNWKHSRZHUYROWDJH ,VWKHYROWDJHEHWZHHQ7HUPLQDO EORFN19DFa9DF" &DXVH 2YHUFXUUHQW $&SDUWDQGSDWWHUQVKRUWRI,QGRRU 3%$ $&SDUWDQGSDWWHUQVKRUWRI2XWGRRU 3%$ :URQJDVVHPEO\ ,QVWDOODWLRQVHUYLFHFRQGLWLRQLVEDG 3RZHUFRUGLVIDXOW\,QGRRU3%$ IDXOW:URQJ3RZHUFDEOH:LULQJ /1(ZLUHZURQJZLULQJ7HUPLQDO %ORFN3%$ ,VWKH3)&LQSXW )XVHRSHQ YROWDJH9DFa9DF" 37&RSHQ 5<5<LVIDXOW\ 2XWGRRU0LFRP,&HUURU 6XSSO\SRZHUDQGRSHUDWHWKHVHW 3RZHUFLUFXLWLVIDXOW\ ,VWKH&(YROWDJH9GFaGF" 8VH5HPRWHFRQWUROEXWWRQLQ /RDGVKRUW LQGRRUVHW 3)&LVIDXOW\ ,VWKH&(YROWDJH9GFaGF" 5HDFWRUZLUHLVZURQJFRQQHFWLRQ 6ZLWFKLQJ7UDQVRI3RZHUFLUFXLWLV ,VWKHYROWDJH&(YROWDJH9GF" IDXOW\ / G K W 6ZLWFKLQJ7UDQVRI3RZHUFLUFXLWLV ,VWKHYROWDJH&(YROWDJH9GF" IDXOW\ / G K W 6ZLWFKLQJ7UDQVRI3RZHUFLUFXLWLV ,VWKHYROWDJH&(YROWDJH IDXOW\ 9GF" /RDGVKRUW 1RUPDO5('RQ*51EOLQN<(/RII $EQRUPDO /1&ZLUHZURQJZLULQJ $OORIIFKHFNQRSRZHU &KHFNWKH/('ODPSGLVSOD\ 2XWGRRU3%$LVIDXOW\ DEQRUPDOGLVSOD\FKHFNHUURU PRGH 6DPVXQJ(OHFWURQLFV 12. Reference Sheet 12-1 Low Refrigerant Pressure Distribution Note : Please measure the refrigerant pressure after the air conditioner operates on testing cooling mode during more than 10 minutes. ■ Indoor Temp. Variation : 20°C ~ 32°C ■ Outdoor Temp. Variation : -5°C ~ 45°C 12-2 Pressure & Capacity mark ■ Power/Heat W cal/s kcal/h Btu/h HP kg.m/s Ib.m/s 1 0.23885 0.85985 3.4121 0.001341 0.10197 0.73756 4.1868 1 3.6 14.286 0.0056146 0.42693 3.088 1.163 0.27778 1 3.9683 0.0015596 0.11859 0.85778 0.29307 0.06999 0.252 1 3.9302x10-4 0.029885 0.21616 745.7 178.11 641.19 2,544.4 1 76.04 550 9.8067 2.3423 8.4322 33.462 0.013151 1 7.233 1.3558 0.32383 1.0658 4.6262 0.0018182 0.13826 1 Samsung Electronics 12-1 12-3 Q & A for Non-trouble Classification Class Cooling Q The cooling is weak. A When it is hot outside, its cooling capacity decreases due to the increase of the ambient temperature. When the dust filter gets blocked or warm outside air gets in, the cooling capacity will decrease. So, make sure to clean the dust filter frequently, prevent heat loss by closing the doors and insulate the cooling area by using curtains, blinds, shades or window tinting. Q The cooling is good generally. But, it gets weak when it is considerably hot. A It occurs when the outdoor unit is exposed to direct sun light and heat-up air is not ventilated well. So, set up a sunblind over the outdoor unit and keep stuff away from the unit to increase the ventilation. When the cooling capacity decreases during a heat wave, clean the heat exchanger of the outdoor unit or spray some cold water to the heat exchanger to increase the cooling capability. Q The cooling is weak. Does it need refrigerant charging? A It is not correct charging refrigerant regularly. Except that you have moved in several times or the connection pipes are broken, the refrigerant does not run low. So, when refrigerant is additionally charged, it could be costly and cause a product's failure. When the refrigerant leaks, all of it will escape in a short time resulting in cooling failure and no water coming out of the drain hose. So, if water comes out from the drain hose, it indicates the normal operation of the product and it does not need refrigerant charging. Q It fails to do cooling. A When the air conditioner is set to ventilation or the desired temperature is set higher than the current temperature, it fails to do cooling. In this case, select cooling or set the desired temperature lower. Q A It floods the floor. Place the drain hose properly. When it is not placed properly, the drain water would flow back flooding the floor. So, straighten out the drain hose for the water to be drained well. Q Water drips at the drain connection (service valve) of the outdoor unit. A When a glass bottle is taken out of the refrigerator, moisture gets condensed on its surface due to the temperature differences. The same principle applies to the air conditioner. When cold refrigerant goes through the copper tube, moisture gets condensed on the surface of the tube and the connection areas. To prevent the water condensation, the pipes are insulated. But, the connection areas of the outdoor unit are not insulated for the purpose of maintenance or repair, and water gets condensed due to the temperature differences and drips down. Generally, it evaporates right away. But, when it drips much during muggy days, put a water pan on the floor. Q It leaks even though a drain pump is used. A It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer. Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump problems. Q Whenever the air conditioner is turned on, it irritates my eyes and gives me a headache. A There are no components in the air conditioner irritating the eyes and sending out chemical smells. But, when the air conditioner is turned on, other smell sources are sucked into the air conditioner and get out of it. So find and root out the smell sources. Generally, it occurs at a interior renovated place, a pharmacy, a gasoline handling place, a tire shop, a second-hand book shop or an electronic component handling place, when its chemical or musty smells are sucked in and sent out, it can be misled that the air conditioner generates them. Leakage Smells 12-2 Description Samsung Electronics Classification Class Smells Q Whenever the air conditioner is turned on, it stinks. A When are no components in the air conditioner sending out chemical smells. But, when the air conditioner is turned on, other smell sources are sucked into the air conditioner and get out of it. So, find and root out the smell sources. Generally, when the drain hose is taken out to the washing room or there are sources of smells such as a diaper bin, a shoe shelf or a socks bin, bad smells generate. Also, it occurs where glass cleaners or air fresheners are used; when they are sucked in interacting with dusts and moistures inside, bad smells generate. these kinds of organic materials noxious to human bodies. So, we recommend against the use of them. Q Whenever the air conditioner is turned on, it smells sour. A When the room is papered recently, its paste smells would be sucked inside. Also, when the air conditioner is installed in the study room of young boys loving sweat-generating activities such as the basketball, excessive sweats evaporate and get sucked into the air conditioner resulting in bad smells. So, find and root out problem or refresh the room frequently. Q Whenever the air conditioner is turned on, it smells musty. A It is due to the improper keeping of the product after its use. When keeping the product, dry up the inside with the operation of ventilation to prevent must. When the product is kept without drying up the inside with ventilation, mold would grow inside resulting in must. So, open the windows and switch on the ventilation function to get rid of the saturated smell inside. Q Whenever the air conditioner is turned on, it sends out bad smells such as stale smells. A It occurs generally when there are pet animals in the house. Their smells stay at the same place. But, when the air conditioner is turned on, the air gets circulated resulting in the circulation of the smells. So, find and root out the problem or refresh the room frequently. Q A Operation Description It sends out bad smells. When the air filter is filthy, it could send out bad smells. So, clean the filter and ventilate the room with the windows open while operating the ventilation function. Q It won't start. A There is a power failure or it is plugged out. Also, check if the power distribution panel is switched off. Q It goes off during operation. A When the hot air does not escape properly, it goes off during operation. it occurs when it does not ventilate properly because the outdoor unit is covered, the back of the outdoor unit is blocked by a cardboard or a plywood panel, and the front of the outdoor unit is blocked by the closed window or other obstacles. Clear the above obstacles from the outdoor unit. Q It generally works properly. But, when it's considerably hot, it goes off during operation. A It occurs when the outdoor unit is exposed to direct sunlight and the hot air does not escape properly. Set up a sun blind over the outdoor unit and clear the neighboring obstacles from the outdoor unit to provide good ventilation. When it goes off frequently during a heat wave, it would prevent the turnoff and increase the cooling capacity cleaning the outdoor unit or spraying some water to the heat exchanger. Q The remote controller won't operate. A When the batteries run out or the transmitter or receiver of the remote controller is blocked by obstacles, change the batteries or keep the obstacles away from the controlling area. Also, the remote controller may mot work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. In this case, take the remote controller closer to the receiver. Samsung Electronics 12-3 Classification Class Q Who installs the air conditioner? (Relocation/Re-installation) A When relocating or re-installing the air conditioner, make sure to contact Samsung Electronics Service Center or Authorized Service Agent and have them to do the job. (If not, it could cause personal injury or product damage.) The cost for the relocation/re-installation of the air conditioner is subject to the customer's expense. There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process. Q Is it possible to install the outdoor unit outside? A It is possible to install it at a designated place in the apartment or on the rooftop nearby. But, it's illegal hanging an angle iron case with the outdoor unit in it outside the apartment. Also, it is illegal obstructing passers-by with the outdoor unit installed outside. Q What can be done to install the outdoor unit facing the road because it is a commercial building? The following is an excerpt from building code going into effect from JUNE 1 st 2005. "The exhaust pipe of a cooling or ventilation facility installed in a building adjacent to the streets of commercial or residential areas shall bel installed higher than 2 m to prevent the exhaust air from blowing directly to passersby and the current facilities shall be corrected by MAY 31 st 2005." So, please install it higher than 2 m or not to blow the hot exhausting air directly to passers-by. What about installing a windscreen during installation not to blow hot air directly to passers-by? When the hot air from the front of the outdoor unit is blocked, the product's performance will be affected and it will fail to operate properly. So, keep it at least 300mm away from its surrounding walls and give it good ventilation. Installation A Q A 12-4 Description Samsung Electronics 12-4 Cleaning /Filter Change 12-4-1 Cleaning your Air Conditioner To get the best possible use out of your air conditioner, you must clean it regularly to remove the dust that accumulates on the air filter. Filtro de aire Remove the air filter from the main body. Insert the air filter back in its original position Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy , rinse it with running water. Dry the Air filter in a ventilated area. it once a week. Samsung Electronics 12-5 12-5 Installation 12-5-1 Before Installation Keep the air conditioner outlet and inlet free from its surroundings. In case of installation, keep the symmetry and fix it to prevent vibration. The pipe length shall meet the standard as far as possible. 12-5-2 Installation Procedure ■ Location Install the product in an area to guarantee the best cooling effect, convenience of piping and electric work, and inexistence of vibration or wind. ■ Wall Drilling Drill the wall downward in a diameter of 60 to 65mm. ■ Fixing Indoor Unit & Outdoor Unit Fix the air conditioner indoor unit securely to the wall. Secure the outdoor unit in a suitable position. ■ Pipe Spooling & Connectingt You shall cut the pipe with a pipe cutter and grind all the burrs of the cut surface. pipe expansion may continue until the pipe surface becomes uneven or torn apart. Be sure to use a torque wrench to tighten pipes or flare nuts. <Torque & Depth> Outer Diameter (D) Torque(kgf·cm) Depth(A) ø6.35 mm(1/4") 140~170 1.3 mm ø9.52 mm(3/8") 250~280 1.8 mm ø12.70 mm(1/2") 380~420 2.0 mm ø15.88 mm(5/8") 440~480 2.2 mm ø19.05 mm(4/4") 9900~1,210 2.2 mm Pipe Flare ■ Leak Test Put an inset gas like nitrogen in the outdoor unit pipe and put soap bubbles or other test liquids on the pipe surface for the leak test. ■ Drain Hose Connecting Install the drain hose downward to drain water naturally. Be sure to pour water into the hose to check if it drains well. ■ Electric & Earth Work Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric Business Laws. ■ Inspection & Trial Run Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the installation. 12-6 Samsung Electronics 12-6 Installation Diagram of Indoor Unit and Outdoor Unit 12-6-1 Air-Purge Procedure 1) Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut. Indoor unit Outdoor unit A Gas pipe side B Liquid pipe side D C 2) Connect the charging hose of low pressure side of manifold gauge to the packed valve having a service port (3/8" Packed valve) as shown at the figure. 3) Open the valve of the low pressure side of manifold gauge counter-clockwise. 4) Purge the air from the system using vacuum pump for about 30 minutes. - After that, please recheck that pressure is stabilized. - Close the valve of the low pressure side of manifold gauge clockwise. - Remove the hose of the low pressure side of manifold gauge. 5) Set valve cork of both liquid side and gas side of packed valve to the open position. 6) Mount the valve stem nuts to the 2 way and 3 way valve. And mount the service port cap to 3 way valve. Vacuum Pump Valve stem Stem cap 7) Check for gas leakage. - At this time, especially check for gas leakage from the 3 way valve's stem nuts, and from the service port cap. A (gas) B (liquid) Samsung Electronics 12-7 12-6-2 "Pump down" Procedure Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area. 1) Remove the caps from the 3 way valve and the 3 way valve. 2) Turn the 3 way valve clockwise to close and connect a pressure gauge (low pressure side) to the service valve, and open the 3 way valve again. 3 way Valve 2 way Valve 3) Set the unit to cool operation mode. (Check if the compressor is operating.) 4) Turn the 3 way valve clockwise to close. 5) When the pressure gauge indicates "0" turn the 3 way valve clockwise to close. 6) Stop operation of the air conditioner. 7) Close the cap of each valve. Relocation of the air conditioner t3FGFSUPUIJTQSPDFEVSFXIFOUIFVOJUJTSFMPDBUFE t$BSSZPVUUIFQVNQEPXOQSPDFEVSFSFGFSUPUIFEFUBJMTPGAQVNQEPXOh t3FNPWFUIFQPXFSDPSE t%JTDPOOFDUUIFBTTFNCMZDBCMFGSPNUIFJOEPPSBOEPVUEPPSVOJUT t3FNPWFUIFGMBSFOVUDPOOFDUJOHUIFJOEPPSVOJUBOEUIFQJQF t"UUIJTUJNFDPWFSUIFQJQFPGUIFJOEPPSVOJUBOEUIFPUIFSQJQFVTJOHBDBQPSWJOZMQMVHUPBWPJEGPSFJHONBUFSJBM entering. t%JTDPOOFDUUIFQJQFDPOOFDUFEUPUIFPVUEPPSVOJU At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering. t.BLFTVSFZPVEPOPUCFOEUIFDPOOFDUJPOQJQFTJOUIFNJEEMFBOETUPSFUPHFUIFSXJUIUIFDBCMFT t.PWFUIFJOEPPSBOEPVUEPPSVOJUTUPBOFXMPDBUJPO t3FNPWFUIFNPVOUJOHQMBUFGPSUIFJOEPPSVOJUBOENPWFJUUPBOFXMPDBUJPO 12-8 Samsung Electronics 12-7.Reference Sheet Index for Model Name 1st 2nd Project A R ITEM RAC FAC WAC 3rd 4th Capacity 1 2 1ST A A A 2ND R F W 5th Sell F Item 1 2 3 4 5 6th 7th Feature S S Reference Export Export Export Export Export 8th 9th Series S B 3TH 4TH 0 9 1 2 1 8 2 4 3 0 10th 11th Color W K Item 5TH 12Year E 13Year F 14Year H 15Year J 16Year K Item2 Item1 7TH Export The virus doctor (The India / Latin America A / PAC K besides) S Export NO virus doctor (the India / Latin America A / PAC K besides) F Special instructions: About AR**FSSSCUR/SA ,the 7TH is “S”, but there is no virus doctor in these models. Item 1 Export Export Export Export Item 2 RAC RAC RAC RAC Item 3 FMC FLG (Best) FMC DLX (Better) FMC STD (Good1) FMC ENT (Good2) 1ST 1ST 1ST 1ST A3050 Item 6TH INVERTER HP S INVERTER CO V 9TH DIGIT Export 1st MODEL 2nd Export Export 3rd MODEL Export 4th MODEL Export 5th MODEL 1 Twilight Best Best TBD Twilight Better Better TBD Twilight Good1 Good1 Midnight Blue Twilight Good2 Good2 TBD The existing code The sales area XSA A B C D E Grille Grille Grille Grille Grille Deco Grille Grille Sinkeolreo code Remark (10TH,11TH) WK TBD WK TBD WK Deco : Transparency Grille : Twilight UR WK TBD Grille : Metalic Gray Item1 Item2 12TH / Export SET N Export IN Export OUT X Item 13th 14th Export S A 8TH 9TH MODEL F MODEL D MODEL S MODEL N Division Series Project Color Name Division component F F D D S S N N 12th Unit N/X AUSTRALIA The integrated code (13TH,14TH) AUSTRALIA(XSA SA CIS Desription This Service Manual is a property of Samsung Electronics Co., Ltd. Any unauthorized use of Manual can be punished under applicable International and/or domestic law. © Samsung Electronics Co., Ltd. August. 2013. Code No. AC-00045K_1 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- 2 step cooling
- single user mode
- Crystal Gloss design
- Smart Wi-Fi
- Smart Installation
- Smart Check
- Triple Protector Plus
- Easy Installation
- Easy Filter
Frequently asked questions
You can approach the test mode by pressing the on/off switch of the indoor unit for 5 seconds.
When an Error occurs, display the Error Mode.
1. Tack out the batteries of remote control. 2. Press the temperature button simultaneously and insert the battery again. 3. Make sure the remote control display shown as .
When pressing the operation ON/OFF key with the direction of remote control for unit, the sound ’’Ding’’ or ’ and the OPERATION ICON( ) lamp of the display is flickering at the same time, then the input of option is completed. (If the deriving sound isn’t heard, try again pressing the ON/OFF button.)
The Test Mode allows you to check if each component is operating normally after installation by operating the cool mode by force without the compressor ON/OFF according to the set temperature/indoor temperature.
The necessary tools are a +SCREW DRIVER, MONKEY SPANNER, and a - SCREW DRIVER.
Before throwing out the air conditioner, remove the batteries from the remote control. Consult your dealer when you dispose of the air conditioner. If pipes are removed incorrectly, refrigerant may blow out and cause air pollution. When it contacts with your skin, it can cause skin injury.
If any kind of liquid spills on the air conditioner, turn off the air conditioner and contact an authorized service center.
1. Enter the Option Setup mode. 2. Enter the Options Setup mode and select your options asscording to the following procedure. 3. Upon completion of the selection, check you made right selections. Press the Mode Selection key to set the display part and check the display part. 4. Pressing the ON/OFF button ( ). 5. Enter the Options Setup mode and select your options asscording to the following procedure. Step 1 (Enter the Option Setup mode) is executed. (Seg25 ~ 48 for setting remote control Setup) Push the Mode button to set the display panerl to 2. Every time you push the button, the display panel reads . . . Push the Mode button to set the display panerl to 1. Every time you push the button, the display panel reads . . .