1. Scope

This document specifies the steps to insert or remove the DF63 series.

It contains general guidelines and precautions for the safe use of the product. The use of the product in a way not as specified in the document could result in unexpected troubles such as damage to connectors. Please make sure to thoroughly read and understand the document prior to the use of the product.

2. Connectors

Part No.

DF63%-*S-3.96C(##)

Description

Socket

DF63%-*P-3.96DS(A)(##)

DF63%-*EP-3.96C(##)

DF63%-****SC(F)(A)

DF63%-****PC(F)(A)

Header

In-line Plug

Crimp contact

( E.g.

) DF63-3S-3.96C

+DF63-1618SCF(Cables attached)

COUNT DESCRIPTION OF REVISIONS

名 称 TITLE

( E.g.

) DF63M-3P-3.96DSA

DF63M-3P-3.96DS

DF63-3EP-3.96C

DF63A-3EP-3.96C

Fig1.DF63 connector

DESIGNED CHECKED

DF63 Series Mating / Unmating Operation Instruction Manual

TECHNICAL SPECIFICATION

FORM HC0011-9-1

DATE

APPROVED

CHECKED

HIROSE ELECTRIC CO.,LTD.

HS.OKAWA

SZ.ONO

20190514

20190514

DESIGNED TO.KUROMATSU 20190514

WRITTEN TO.KUROMATSU 20190514

ETAD-H0892-00 △ 1 / 6

3. Operation procedure

3-1. Insertion

3-1-a. Positioning for insertion:

: Adjust the position for insertion according to the locks of the socket or In-line plug.

Center position

Fig2. Positioning for insertion

3-1-b. Insertion:

Insert the socket till it clicks while retaining the adjusted position.

Then, it is not needed to handle the lock portion

(If it is inserted the socket by pushing the lock portion, it does not hear click sound.)

Lock portion

Direction of insertion

FORM HC0011-9-2

HIROSE ELECTRIC CO.,LTD.

Fig.3 Insertion

ETAD-H0892-00 △ 2 /6

To avoid degraded quality, do not tilt the socket for insertion as shown in the figure below.

3-1-c. Check fitting:

Fig.4 Prohibited insertion

Make sure the socket has been firmly fit with the header or In-line plug.

(Check that the socket lock has been caught at the header lock or In-line plug lock by slightly pulling a cable by hand.)

To remove the socket, refer to 3-2. Socket removal.

FORM HC0011-9-2

HIROSE ELECTRIC CO.,LTD.

ETAD-H0892-00 △ 3 /6

3-2. Socket removal

3-2-a. Removal:

: Remove the socket while pressing with a finger the lock spring on the socket to unlock.

Lock spring

Direction of removal

Fig.5 Socket removal

To avoid degraded quality, do not tilt the socket for removal as shown in the figure below.

Fig6. Forbidden removal

FORM HC0011-9-2

HIROSE ELECTRIC CO.,LTD.

ETAD-H0892-00 △ 4 /6

Attention ) Not to remove socket in the locked status as it will lead to breakage of locking portion or cable broken.

If remove socket in the locked status, the lock is engaged to header lock portion as below picture shown. Then, it can not handle the lock. In this case, please insert the socket once. After that, handle the lock portion.

Unable unlock

Caught in lock portion

Insert direction

Able unlock

Fig7. How to handle to avoid unable unlock status

FORM HC0011-9-2

HIROSE ELECTRIC CO.,LTD.

ETAD-H0892-00 △ 5 /6

4. Precautions

・ Do not insert or remove the socket while electrifying.

・ Excessive external force applied to connectors could cause fault or damage.

Therefore, avoid forced insertion or removal, impacts given by falling, or forced pulling of cables.

・ Avoid insert socket by bundling the cable or applying stress to the socket like below picture shown.

Fig8. Forbidden insertion

FORM HC0011-9-2

HIROSE ELECTRIC CO.,LTD.

ETAD-H0892-00 △ 6 /6