Avlite AV-OL ILAB-12-R-D, FL810-12-R-D Universal DC Low Intensity Obstruction Light Installation & Service Manual
Below you will find brief information for Universal DC Low Intensity Obstruction Light AV-OL ILAB-12-R-D, Universal DC Low Intensity Obstruction Light AV-OL FL810-12-R-D. This Avlite dual light fixture is a steady burning, low intensity LED obstruction light designed to comply with FAA L-810 and ICAO LIOL Type A & B requirements. The model can be used for marking obstacles up to 45 metres above ground, such as telecommunication towers, wind turbines, buildings and other tall structures. The dual light fixture can be configured to different operational states. Both light fixtures may be set to operate steady-burning. Alternatively, the dual light fixture may consist of a main light and a standby light. If the main light should ever fail the standby light will automatically switch on to ensure the obstacle is always clearly marked. The light fixture incorporates internal diagnostic checking and an alarm contact for remote monitoring.
Advertisement
Advertisement
AV-OL-ILAB-12-R-D & AV-OL-FL810-12-R-D Universal DC Low Intensity Obstruction Light Dual Fixture Installation & Service Manual Version 1.0 Universal DC Low Intensity Obstruction Light Dual Light Fixture Table of Contents Introduction...........................................................................................Page 4 Technology............................................................................................Page 4 AV-OL-ILAB-12-R-D & AV-OL-ILAB-12-R-D Models...........................Page 5 Safety Information................................................................................Page 8 Unpacking, Mounting, Wiring & Setup...............................................Page 8 Unpacking....................................................................................Page 8 Mounting......................................................................................Page 8 Installation & Wiring.....................................................................Page 8 Opening & Closing the Light Head.............................Page 9 Operation & Setup.....................................................................Page 11 Intensity & Operation Mode Setting..........................Page 12 Alarm Relay Output..................................................Page 13 RS232 & RS422/485 Communications (Optional)...Page 13 Optional GSM Monitoring & Control System...................................Page 15 Maintenance & Servicing...................................................................Page 16 Trouble Shooting................................................................................Page 17 Appendix.............................................................................................Page 18 Light Head Wiring Diagram.......................................................Page 18 Light Head Systems Diagram....................................................Page 19 Light Head Parts Diagram.........................................................Page 20 Main Enclosure Parts Diagram..................................................Page 21 Product Order Codes.................................................................Page 22 Certifications & Compliance......................................................Page 23 Avlite Light Warranty..........................................................................Page 26 Version No. 1.0 Description Manual launch Date Mar 2015 Approved W. Evans Latest products and information available at www.avlite.com 3 Universal DC Low Intensity Obstruction Light Dual Light Fixture Introduction Congratulations! By choosing to purchase an Avlite light, you have become the owner of one of the most advanced solar LED obstruction lights in the world. Avlite Systems draws on more than 25 years experience in the design and manufacture of navigation aids, and particular care has been taken to ensure your light gives years of trouble free service. As a commitment to producing the highest quality products for our customers, Avlite has been independently certified as complying with the requirements of ISO 9001:2008 quality management system. By taking a few moments to browse through this booklet, you will become familiar with the versatility of your light, and be able to maximise its operating function. Please remember to complete the Avlite warranty registration card accompanying your light. Technology Avlite Systems is a world-class solar lighting systems manufacturer with a proven reputation for rapid, innovative, and agile technology solutions designed specifically for defense, government, civil and humanitarian aid operations in the most remote, toughest environments. Electronics Avlite employs leading in-house electronic engineers in the design and development of software and related circuitry. All individual electronic components are sourced directly by Avlite procurement staff ensuring that only the highest quality components are used in our products. LED Technology All Avlite lights use the latest advancements in LED (Light Emitting Diode) technology as a light source. The major advantage of LED’s over traditional light sources is well established in that they typically have an operational life in excess of 100,000 hours, resulting in substantial savings to maintenance and servicing costs. Precision Construction Commitment to investing in the design and construction of injection-moulded parts including optic lenses, light bases and a range of other components ensures that all Avlite products are of a consistent and superior quality. Optical Performance Avlite manufactures a range of aviation LED lenses moulded from multi-cavity dies. The company has superior in-house lens manufacturing capabilities to support outstanding optical performance. Award-winning, Patented Technology Several United States and Australian patent registrations are held on Avlite’s range of innovative designs, with other regional patents pending in Canada, United Kingdom and Europe. Latest products and information available at www.avlite.com 4 Universal DC Low Intensity Obstruction Light Dual Light Fixture AV-OL-ILAB-12-R-D & AV-OL-FL810-12-R-D Models This Avlite dual light fixture is a steady burning, low intensity LED obstruction light designed to comply with FAA L-810 and ICAO LIOL Type A & B requirements. The model can be used for marking obstacles up to 45 metres above ground, such as telecommunication towers, wind turbines, buildings and other tall structures. Avlite’s LED obstruction lights offer an ultra bright, energy efficient and cost effective lighting solution. The dual light fixture can be configured to different operational states. Both light fixtures may be set to operate steady-burning. Alternatively, the dual light fixture may consist of a main light and a standby light. If the main light should ever fail the standby light will automatically switch on to ensure the obstacle is always clearly marked. The light fixture incorporates internal diagnostic checking and an alarm contact for remote monitoring. The alarm relay is energised in normal operation and is released whenever the LED is not lit. Latest products and information available at www.avlite.com 5 Universal DC Low Intensity Obstruction Light Dual Light Fixture Combined visual & infrared for visibility to pilots using night vision (optional) Single LED Optic Automatic night operation Tough UV-stabilised LEXAN® polycarbonate lens & light base 2.83in 72.0mm Robust 7-stage powder-coated aluminium housing 8.58in 218.0mm 10.32in 262mm 18.95in 481mm Latest products and information available at www.avlite.com 6 SPECIFICATIONS•* 12-48 VDC Light Characteristics Light Source Available colors Peak Intensity (cd)† Horizontal Output (degrees) Vertical Divergence (degrees) Reflector Type Intensity Adjustments Operation Mode Adjustment LED Life Expectancy (hours) As tested; ICAO: AV-OL-ILAB-12 (Type A) & AV-OL-ILAB-12 (Type B) FAA: AV-OL-FL810-12-R LED Red as standard. Other colors available on request, including IR Complies with ICAO LIOLA & LIOLB and FAA L-810 obstruction lights 360 ICAO Model: as per ICAO Type A/B specification FAA Model: as per FAA L-810 obstruction light specification Single LED Optic ICAO Model: User-adjustable between 10cd & 32cd FAA Model: 32.5cd User-adjustable between dusk-till-dawn & 24 hour operation >100,000 Electrical Characteristics Current Draw (mA)‡ Power (W)‡ Current Draw (mA)‡ Power (W)‡ • Specifications subject to change or variation without notice * Subject to standard terms and conditions † Intensity setting subject to solar availability ‡ When used in redundant failsafe mode Circuit Protection Operating Voltage Temperature Range Failover Configuration @ 12V: ICAO LIOL Type A @ 10cd Steady-on with relay energised: Imax = 55 ICAO LIOL Type B @ 32cd Steady-on with relay energised: Imax = 120 FAA L-810 @ 32.5cd Steady-on with relay energised: Imax = 120 ICAO LIOL Type A @ 10cd Steady-on with relay energised & IR: Pmax = 0.66 ICAO LIOL Type B @ 32cd Steady-on with relay energised & IR: Pmax = 1.44 FAA L-810 @ 32.5cd Steady-on with relay energised & IR: Pmax = 1.44 Dual Lit Configuration @ 12V: ICAO LIOL Type A @ 10cd Steady-on with relay energised: Imax = 110 ICAO LIOL Type B @ 32cd Steady-on with relay energised: Imax = 240 FAA L-810 @ 32.5cd Steady-on with relay energised: Imax = 240 ICAO LIOL Type A @ 10cd Steady-on with relay energised & IR: Pmax = 1.32 ICAO LIOL Type B @ 32cd Steady-on with relay energised & IR: Pmax = 2.88 FAA L-810 @ 32.5cd Steady-on with relay energised & IR: Pmax = 2.88 Integrated 12 – 48 VDC -40 to 80°C Physical Characteristics Body Material Lens Material Lens Diameter (mm/inches) Lens Design Mounting Height (mm/inches) Width (mm/inches) Mass (kg/lbs) Product Life Expectancy 7-stage powder-coated aluminium LEXAN® Polycarbonate – UV stabilized 100 / 37/8 Single LED Optic ICAO Model: 4 x 6.5mm mounting holes FAA Model: ¾ inch pipe thread ICAO Model: 262 / 103/8 FAA Model: 272 / 10¾ 481 / 19 2.3 / 5 Up to 12 years Environmental Factors Humidity Icing Wind Speed 0 to 100%, MIL-STD-810F 22kg per square inch Up to 240kph Certifications CE Quality Assurance EN61000-6-3:1997. EN61000-6-1:1997 ISO9001:2008 ICAO FAA Waterproof Low Intensity Obstruction Light Type A & B L-810 Steady-burning Red Obstruction Light IP67 Intellectual Property Trademarks Warranty * Options Available AVLITE® is a registered trademark of Avlite Systems 3 year warranty • Variety of solar/battery configurations • GSM Cell-Phone Monitoring • Dual visual/IR output • IR LED • RS422/485 communications port Universal DC Low Intensity Obstruction Light Dual Light Fixture Safety Information Safety Information • Install the light in compliance with the effective local electrical code(s). • Mains power should always be disconnected when work is being done in close proximity to electrical fittings, and electrical work should only be done by a licensed and certified professional. • Operate the light only within the indicated electrical ratings and product usage instructions. • To ensure that the light and peripheral equipment function safely and correctly, use cable in compliance with the effective local electrical code. • Do not stare at the LED or shine the LED into your eyes or those of another person. • Do dispose of the product according to the local laws and regulations for your region, for example, at a recycling center that accepts electronic devices. Unpacking, Mounting, Wiring & Setup Unpacking Unpack all hardware and inspect for damage. If there is any damage, please contact your Avlite Office. Retain original packing material for possible future use in shipping. Mounting Mount the Obstruction Light using its four mounting holes. Make sure the light is horizontally aligned to guarantee the required beam pattern of the obstruction light. Installation & Wiring Before proceeding with installation or service, make sure the following conditions are met: • Ensure the tower or mast is grounded (No RF HAZARD) • Check the mast lighting circuit is not faulty • Ensure power lines are not ‘live’ (NO ELECTRICAL HAZARD) • Avoid touching live circuits! • Avoid touching any component or any part of the circuitry while the unit is operating. Do not change components or make adjustments inside the unit with power on. NOTE: The unit must be installed by a qualified and certified professional. Latest products and information available at www.avlite.com 8 Universal DC Low Intensity Obstruction Light Dual Light Fixture OPENING AND CLOSING THE LIGHT HEAD(S) Remove the locking screw In order to open the unit, the top half of the unit should be turned anti-clockwise with respect to the bottom half. The top half will turn approximately 20mm over a positive “click” before separating from the bottom half. Attention should be paid to the restriction caused by the internal cabling which is secured by a cable gland. The unit is closed by reversing the above procedure, ensuring the black rubber O-ring remains in place. Locking Screw Figure 2. Obstruction Light head DC POWER CONNECTION 1.Open the top lid by unscrewing the 6 top screws and removing the lid. Wire up the light and connect power to the terminal block. Please refer to Figure 1. 2. Wire as follows: • Positive supply (+) = +VDC • Negative supply (-) = 0V 3. Close the lid using all 6 top screws. Make sure the black rubber O-ring remains in place during that process. NOTE: • The unit is designed to operate from a nominal DC voltage from 12V to 48V. • Use cable in compliance with the effective local electrical code. The cable outer diameter should be between 5mm and 10mm. Avlite recommends the following number of cores and size[mm²]: 2 x 0.75 or 2 x 1.0 • Color coding may vary depending on country and local regulations. Latest products and information available at www.avlite.com 9 Universal DC Low Intensity Obstruction Light Dual Light Fixture OV Mounting plate +VDC Terminal Block Colour CONNECTOR SIGNAL Brown Terminal block 12V – 48V Blue Terminal block 0V Dual lit wiring configuration ry Light Primary Light SecondarySecondary Light Li Mounting plate 0V Terminal Block +VDC 0V COLOUR Brown Blue Mounting plate Terminal Block +VDC CONNECTOR COLOUR Terminal Block Brown Terminal Block Blue SIGNAL CONNECTOR 12-48V Terminal Block 0V Terminal Block SIGNAL 12-48V 0V Fail-over wiring diagram Figure 1. DC Wiring Diagram Latest products and information available at www.avlite.com 10 Universal DC Low Intensity Obstruction Light Dual Light Fixture Operation & Setup When powered up, the light will constantly check day/night status using its internal ambient light sensor. The ambient light sensor averages its measurement for 30 seconds. FAA: By default the lights turn ON when the ambient light decreases to not less than 35 footcandles (367.7 lux) and turn OFF when the ambient light decreases to not more than 60 footcandles (645.8 lux). These limits can be factory adjusted, if required. ICAO: By default the lights turn ON when the ambient light decreases to not less than 35 footcandles (100 lux) and turn OFF when the ambient light decreases to not more than 60 footcandles (150 lux). These limits can be factory adjusted, if required. ight Latest products and information available at www.avlite.com 11 Universal DC Low Intensity Obstruction Light Dual Light Fixture INTENSITY & OPERATION MODE SETTING Light intensity & operation mode setting for ICAO compliant light fixture The fixture will be supplied with the ICAO compliant optic. The obstruction light will be pre-set to the intensity setting specified by the customer (ICAO Type A or ICAO Type B) for a red steady burning Low Intensity Obstruction Light in dusk-till-dawn mode. The intensity and operation mode is pre-set in the factory and does not need to be set by the user. If the customer should need to change the intensity or operation mode settings of the ICAO compliant model they can do this by changing the INTENSITY DIP switch. Please refer to table below for DIP switch settings and Figure 3 for circuit board location. Position 2 Position 1 OFF OFF Light Intensity ICAO Low Intensity Obstruction Light Type A (10cd), dusk-till-dawn mode – DEFAULT OFF ON ICAO Low Intensity Obstruction Light Type A (10cd), 24 hour mode ON OFF ICAO Low Intensity Obstruction Light Type B (32cd), dusk-till-dawn mode ON ON ICAO Low Intensity Obstruction Light Type B (32cd), 24 hour mode Light intensity & operation mode setting for FAA compliant light fixture The fixture will be supplied with the FAA compliant optic. The FAA compliant model comes pre-set to the correct intensity for L-810 steady burning red obstruction light in dusk-till-dawn mode. The intensity and operation mode is pre-set in the factory and does not need to be set by the user. If the customer should need to change the operation mode settings of the FAA compliant model they can do this by changing the INTENSITY DIP switch. Please refer to table below for DIP switch settings and Figure 3 for circuit board location. Position 2 Position 1 Light Intensity No function OFF FAA L-810 Low Intensity Obstruction Light, dusk-till-dawn mode – DEFAULT No function ON FAA L-810 Low Intensity Obstruction Light, 24 hour mode NOTE: The ICAO Model and FAA Model have their own unique optic. The ICAO model cannot be used for FAA purposes and the FAA model cannot be used for ICAO purposes. The model required needs to be specified at the time of order. NOTE: The unit must be installed by a qualified electrician. Latest products and information available at www.avlite.com 12 Universal DC Low Intensity Obstruction Light Dual Light Fixture ALARM RELAY OUTPUT In normal operation the relay is energised • Terminal contacts COMM and NC of the relay are electrically closed • Terminal contacts COMM and NO of the relay are electrically open Whenever the LED is not lit due to a power failure and/or a LED failure the relay will not be energised. • Terminal contacts COMM and NO of the relay are electrically closed • Terminal contacts COMM and NC of the relay are electrically open For location details of the terminals please refer to Figure 3. The alarm relay can be configured in three different ways: • Relay normal operation (default, as described above) • Relay inverse operation (inverse functionality of the normal operation, used to conserve power) • Relay disable (in case the relay is not required, used to conserve power) NOTE: The alarm relay is intended for low voltage (SELV) connection only. RS232 & RS422/485 COMMUNICATION (OPTIONAL) The Obstruction Light offers a RS232 and a R2422/485 interface. RS232 Typical 3 pin TxD, RxD and GND arrangement RS422/485 Typical 4 pin arrangement with Termination selection and Duplex/Halfduplex selection For location details please refer to Figure 3. Duplex SW3 Termination SW4 S1 S2 S1 S2 OFF OFF Simplex operation OFF OFF No termination ON ON Duplex operation ON ON 120 Ohm termination Please contact AVLITE for further details. Latest products and information available at www.avlite.com 13 Universal DC Low Intensity Obstruction Light Dual Light Fixture Relay INTENSITY TxD RxD SW2 ALARM GND Figure 3. Obstruction Light PCB with terminals and DIP switches Latest products and information available at www.avlite.com 14 NC NO COMM GND 0V POWER FULL HALF DUPLEX RS-232 1 2 ON ON ON 1 2 1 2 TERMINATE +VDC GND -VE +VE -VE +VE RS-422 Tx Rx Universal DC Low Intensity Obstruction Light Dual Light Fixture Optional GSM Monitoring & Control System The AV-OL Series Dual Light Fixture may also be fitted with GSM Cell-Phone Monitoring and Control – enabling users to access real-time diagnostics data and change light settings via cell-phone. The system can also be configured to send out alarm SMS text messages to designated cellular telephone numbers. Users can also have alarms and reports sent to designated email addresses. Please contact Avlite for further information and instructions. Latest products and information available at www.avlite.com 15 Universal DC Low Intensity Obstruction Light Dual Light Fixture Maintenance & Servicing Designed to be maintenance free the Obstruction Lights require minimal attention, though the following maintenance and servicing information is provided to help ensure the life of your Avlite product. • Occasional cleaning of the dome lens may be required using a cloth and warm soapy water. Latest products and information available at www.avlite.com 16 Universal DC Low Intensity Obstruction Light Dual Light Fixture Trouble Shooting Problem Remedy Light will not activate. • • • • Ensure proper connectivity with power supply Ensure that the power supply has the right polarity and voltage range Ensure wiring is in accordance with Figure 1 Cover the light sensor to force the light ON Latest products and information available at www.avlite.com 17 Universal DC Low Intensity Obstruction Light Dual Light Fixture Appendix Light Head Wiring Diagram Figure 4. Light head wiring diagram shown with optional serial communication Latest products and information available at www.avlite.com 18 Universal DC Low Intensity Obstruction Light Dual Light Fixture Light Head Systems Diagram Light head / electronics Tx RS422 RS485 Rx +VE TxD -VE RxD +VE GND LED driver -VE GND 12VDC48VDC RS232 +VDC NC Micro controller ALARM RELAY NO COMM 0V Light sensor GND Figure 5. Systems Diagram Latest products and information available at www.avlite.com 19 Universal DC Low Intensity Obstruction Light Dual Light Fixture Light Head Parts Diagram dome lens optics PCB with single LED Screw Top enclosure O-ring Security lock Bottom enclosure Cable gland Metal ring Inside thread for pole mounting vent Figure 6. Light head parts diagram Latest products and information available at www.avlite.com 20 Universal DC Low Intensity Obstruction Light Dual Light Fixture Main Enclosure Parts Diagram Figure 7. Parts diagram of the main enclosure Latest products and information available at www.avlite.com 21 Universal DC Low Intensity Obstruction Light Dual Light Fixture Product Order Codes HOW TO ORDER AV-OL Series Obstruction Lights: ICAO Compliant FAA Compliant AV-OL-ILAB-[Model]-[Color]-[?]-[?]-[?]-[?]-[?] AV-OL-FL810-[Model]-[Color]-[?]-[?]-[?]-[?]-[?] Product No.: Product No.: Model: 12 = 12–48 VDC UM = 110–240 VAC Model: 12 = 12–48 VDC UM = 110–240 VAC Color: R = Red IR = Infrared RIR = Combined Red/IR Color: R = Red IR = Infrared RIR = Combined Red/IR Single or Dual Fixture: [blank] = Single light fixture [D] = Dual light fixture Single or Dual Fixture: [blank] = Single light fixture [D] = Dual light fixture Solar/Battery Configuration: CT1 = Type 1 CT2 = Type 2 [blank] = No solar/battery configuration Solar/Battery Configuration: CT1 = Type 1 CT2 = Type 2 [blank] = No solar/battery configuration Monitoring & Control: G = GSM RF = Radio Control [blank] = No monitoring & control Monitoring & Control: G = GSM RF = Radio Control [blank] = No monitoring & control RS Communications Port (12-48VDC Model only): RS = RS communications port [blank] = No RS communications port RS Communications Port (12-48VDC Model only): RS = RS communications port [blank] = No RS communications port Feature: 0 = Both lights activated at the same time 1 = One light activated with automatic changeover ability [blank] = No feature Feature: 0 = Both lights activated at the same time 1 = One light activated with automatic changeover ability [blank] = No feature Latest products and information available at www.avlite.com 22 Universal DC Low Intensity Obstruction Light Dual Light Fixture Certifications & Compliance Certified to: FAA AC NO: 150/5345-43F L-810 (L) FAA Engineering Brief No. 67 FAA Engineering Brief No. 76 (if applicable) Compliant to: ICAO Annex 14 Volume 1, ‘Aerodrome Design and Operations’, Fourth Edition July 2004, Table 6.3, Low Intensity Type A & B Obstruction Light Latest products and information available at www.avlite.com 23 Universal DC Low Intensity Obstruction Light Dual Light Fixture Notes Latest products and information available at www.avlite.com 24 Universal DC Low Intensity Obstruction Light Dual Light Fixture Notes Latest products and information available at www.avlite.com 25 Universal DC Low Intensity Obstruction Light Dual Light Fixture Avlite Light Warranty V1.2 Activating the Warranty Upon purchase, the Avlite Systems warranty must be activated for recognition of future claims. To do this you need to register on-line. Please complete the Online Registration Form at: www.avlite.com Avlite Systems will repair or replace your lantern in the event of electronic failure for a period of up to three years from the date of purchase. Avlite Systems will repair or replace any ancillary or accessory products in the event of failure for a period of up to one year from the date of purchase, as per the terms & conditions below. The unit must be returned to Avlite freight prepaid. Warranty Terms 1. Avlite Systems warrants that any Avlite aviation products fitted with telemetry equipment including but not limited to AIS, GSM, GPS or RF (“Telemetry Products”) will be free from defective materials and workmanship under normal and intended use, subject to the conditions hereinafter set forth, for a period of twelve (12) months from the date of purchase by the original purchaser. 2. Avlite Systems warrants that any rotationally-moulded products (“Roto-Moulded Products”) and accessory products (“Accessory Products”) will be free from defective materials and workmanship under normal and intended use, subject to the conditions hereinafter set forth, for a period of twelve (12) months from the date of purchase by the original purchaser. 3. Avlite Systems warrants that any Avlite aviation products other than the Telemetry Products, RotoMoulded Products and Accessory Products (“Avlite Products”) will be free from defective materials and workmanship under normal and intended use, subject to the conditions hereinafter set forth, for a period of three (3) years from the date of purchase by the original purchaser. 4. Avlite Systems will repair or replace, at Avlite’s sole discretion, any Telemetry Products, RotoMoulded Products, Accessory Products or Avlite Products found to be defective in material and workmanship in the relevant warranty period so long as the Warranty Conditions (set out below) are satisfied. 5. If any Telemetry Products or Avlite Products are fitted with a rechargeable battery, Avlite Systems warrants the battery will be free from defect for a period of one (1) year when used within original manufacturer’s specifications and instructions. Warranty Conditions This Warranty is subject to the following conditions and limitations; 1. The warranty is applicable to lanterns manufactured from 1/1/2009. 2. The warranty is void and inapplicable if: a. the product has been used or handled other than in accordance with the instructions in the owner’s manual and any other information or instructions provided to the customer by Avlite; b. the product has been deliberately abused, or misused, damaged by accident or neglect or in being transported; or c. the defect is due to the product being repaired or tampered with by anyone other than Avlite or authorised Avlite repair personnel. 3. The customer must give Avlite Systems notice of any defect with the product within 30 days of the customer becoming aware of the defect. 4. Rechargeable batteries have a limited number of charge cycles and may eventually need to be replaced. Typical battery replacement period is 3-4 years. Long term exposure to high temperatures will shorten the battery life. Batteries used or stored in a manner inconsistent with the manufacturer’s specifications and instructions shall not be covered by this warranty. 5. No modifications to the original specifications determined by Avlite shall be made without written approval of Avlite Systems. 6. Avlite lights can be fitted with 3rd party power supplies and accessories but are covered by the 3rd Latest products and information available at www.avlite.com 26 Universal DC Low Intensity Obstruction Light Dual Light Fixture party warranty terms and conditions. 7. The product must be packed and returned to Avlite Systems by the customer at his or her sole expense. Avlite Systems will pay return freight of its choice. A returned product must be accompanied by a written description of the defect and a photocopy of the original purchase receipt. This receipt must clearly list model and serial number, the date of purchase, the name and address of the purchaser and authorised dealer and the price paid by the purchaser. On receipt of the product, Avlite Systems will assess the product and advise the customer as to whether the claimed defect is covered by this warranty. 8. Avlite Systems reserves the right to modify the design of any product without obligation to purchasers of previously manufactured products and to change the prices or specifications of any product without notice or obligation to any person. 9. Input voltage shall not exceed those recommended for the product. 10. Warranty does not cover damage caused by the incorrect replacement of battery in solar lantern models. 11. This warranty does not cover any damage or defect caused to any product as a result of water flooding or any other acts of nature. 12. There are no representations or warranties of any kind by Avlite or any other person who is an agent, employee, or other representative or affiliate of Avlite, express or implied, with respect to condition of performance of any product, their merchantability, or fitness for a particular purpose, or with respect to any other matter relating to any products. Limitation of Liability To the extent permitted by acts and regulations applicable in the country of manufacture, the liability of Avlite Systems under this Warranty will be, at the option of Avlite Systems, limited to either the replacement or repair of any defective product covered by this Warranty. Avlite Systems will not be liable to Buyer for consequential damages resulting from any defect or deficiencies in accepted items. Limited to Original Purchaser This Warranty is for the sole benefit of the original purchaser of the covered product and shall not extend to any subsequent purchaser of the product. Miscellaneous Apart from the specific warranties provided under this warranty, all other express or implied warranties relating to the above product is hereby excluded to the fullest extent allowable under law. The warranty does not extend to any lost profits, loss of good will or any indirect, incidental or consequential costs or damages or losses incurred by the purchaser as a result of any defect with the covered product. Warrantor Avlite Systems has authorised distribution in many countries of the world. In each country, the authorised importing distributor has accepted the responsibility for warranty of products sold by distributor. Warranty service should normally be obtained from the importing distributor from whom you purchased your product. In the event of service required beyond the capability of the importer, Avlite Systems will fulfil the conditions of the warranty. Such product must be returned at the owner’s expense to the Avlite Systems factory, together with a photocopy of the bill of sale for that product, a detailed description of the problem, and any information necessary for return shipment. Information in this manual is subject to change without notice and does not represent a commitment on the part of the vendor. Sealite products are subject to certain Australian and worldwide patent applications. Latest products and information available at www.avlite.com 27 Universal DC Low Intensity Obstruction Light Dual Light Fixture Other Avlite Products Available Solar Aviation Lighting Helipad Lighting Obstruction Lighting Airfield Markers & Accessories Typical Applications • Temporary & permanent airfield lighting • Remote, emergency & defence airfield lighting • Barricade, hazard & perimeter lighting • Helipad lighting • Obstruction lighting For a complete list of product compliances including ICAO & FAA, please contact Avlite today Area & Sign Lighting Head Office Avlite Systems 11 Industrial Drive Somerville, Vic 3912 Australia Tel: +61 (0)3 5977 6128 Fax: +61 (0)3 5977 6124 Email: [email protected] Internet: www.avlite.com A subsidiary of Sealite Pty Ltd www.sealite.com Latest products and information available at www.avlite.com 28 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Steady burning, low intensity LED obstruction light
- Complies with FAA L-810 and ICAO LIOL Type A & B requirements
- Dual light fixture
- Automatic failsafe operation
- Alarm relay output
- Optional RS232 and RS422/485 communication
- Optional GSM monitoring and control system