View the catalog online

Particulate Monitoring

Industrial Hygiene and

Safety Instrumentation

800-852-9795 • 866-RENT-EHS (736-8347)

Gas Detection and

Monitoring

First Responder Safety

IAQ and Ventilation

Testing

Sound Level and

Noise Monitoring

Thermal and Optical

Testing

Air Monitoring Gas Analysis Emissions Monitoring

INDuSTrIAL hygIeNe — POrTAbLeS

Products in this catalog are available to rent anywhere in the US. Due to representative agreements with our manufacturer partners, not all products are available for sale in all areas and markets.

511

Delivery and training available only in Illinois, Indiana, Wisconsin, Kentucky, and Eastern Iowa.

Prices are current at publication, and are subject to change without notice.

See

Page

Air Monitoring and Pumps

Sensidyne Gilian Personal Sampling Pumps

Sensidyne Sampling Pump Calibrators

TSI Primary Flow Calibrators

523

525

524

IAQ and Ventilation Testing Instruments

Testo 550 Refrigerant System Analyzer

TSI Alnor 6200 LoFlo Balometer

TSI Alnor EBT731 Electronic Balancing Tool

TSI DP-Calc 5815 and 5825 Micromanometers

TSI HM675/685 Hydronic Manometers

TSI IAQ-Calc Indoor Air Quality Meters

TSI PA200 Positive and Negative Dust Accreditation System

TSI Q-Trak Indoor Air Quality Monitors

TSI VelociCalc Ventilation Meters

Particulate Monitoring

3M Quest EVM-7 Multiparameter Environmental Monitor

TSI AeroTrak 9000 Nanoparticle Aerosol Monitor

TSI AeroTrak Benchtop Airborne Particle Counters

TSI AeroTrak Handheld Optical Particle Counters

TSI DustTrak II and DustTrak DRX Aerosol Particulate Monitors

TSI P-Trak Ultrafine Particle Counter

TSI SidePak AM510 Personal Aerosol Monitors

Sound Level and Noise Monitoring

3M Quest Acoustic Calibrator

3M Quest Portable Noise Dosimeters

3M Quest Cordless Personal Noise Dosimeters

3M Quest Sound Level Meters

3M NI-100 Personal Noise Indicator

3M Detection Management Software

Thermal and Optical Digital Testing Instruments

Testo Thermal Imagers with Built-In Digital Cameras 526

518

517

517

519

518

519

518

519

516

512

515

515

514

512

515

514

520

521

520

522

521

520

Services to Support Our Customers

Online Training

Having trouble figuring out how to get data from your Quest Technologies sound level and noise monitoring devices to your PC? The answers are as close as our Online Training

Center.

In just five minutes, you'll get a step-by-step tutorial on how to load data analysis software on your PC, connect your monitoring equipment to your PC, transfer the data, and view it in the manufacturer's software.

Best yet, they're all available for FREE. Just visit RAECO.com

and click on the Training

Center link in the toolbar.

512

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Advanced Function Aerosol Particulate Monitors

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Features

• DustTrak II measures aerosol particulate mass

• DustTrak DRX measures particulate mass and size fraction at the same time! PM1, PM2.5, Respirable, PM10, and TPM

• Great for spot checks or long-term unattended sampling

TSI's DustTrak II and DRX handheld and desktop aerosol monitors are battery-operated, datalogging, light-scattering laser photometers that give you real-time aerosol mass readings of dust, smoke, fumes, and mists. They're suitable for use in clean office settings, harsh industrial workplaces, construction and environmental sites, and other outdoor applications.

DustTraks use a sheath air systems that isolates the aerosol in the optics chamber, and keep the optics clean for improved reliability and low maintenance.

The graphical color touchscreen interface puts everything at your fingertips. The display shows real-time mass concentration, graphs, and statistics, plus instrument pump, laser and flow status, and more.

You'll use the touchscreen to perform quick walk-through surveys or program the unit's advanced logging modes for long-term sample studies. You'll be able to program the start time, total sampling time, logging intervals, alarm setpoints, and other parameters, or set up the DustTrak for continuous operation.

DustTrak DRX — an industry first!

TSI's DRX model laser photometers simultaneously measure mass and size fraction — something no

other monitor on today's market can do.

Basic photometers can be used at high mass concentrations. But, they don't give any size information unless they're used with sizeselective inlet conditioners. And, they can significantly underestimate large particle mass concentrations.

Optical particle counters can provide size and count information.

But, they don't provide mass concentration data, and can't be used in high mass concentration environments.

The DustTrak DRX improves on the performance of basic photometers or optical particle counters, because it delivers the mass concentration of a photometer with the size resolution of an OPC.

DustTrak DRX is a continuous real-time 90° light-scattering laser photometer that simultaneously measures size-segregated mass fraction concentrations corresponding to PM1, PM2.5, respirable,

PM10, and total PM size fractions. It can combine both particle cloud

(total area of scattered light) and single particle detection to achieve mass fraction measurements.

DustTrak II — Easy update to the DustTrak 8520

DustTrak II monitors are continuous real-time, single-channel

90° light-scattering laser photometers for determining the mass concentration of aerosols. A built-in pump allows the use of a variety of size-selective inlet conditioners to measure aerosol concentrations to PM10, PM2.5, PM1, or respirable size fractions.

Portable models feature single-point datalogging, making them ideal for industrial hygiene walkthroughs and IAQ investigations. The desktop models add user-adjustable alarm setpoints for instantaneous or 15-minute STEL readings.

USB, Ethernet, and wireless communications (depending on model) make it easy to connect to your PC and use TrakPro data analysis software for programming, and data acquisition.

Learn more about the DustTrak II and DRX at www.raeco.com/get/DustTrak.php

3M Quest EVM-7 Multiparameter Environmental Monitor

• Measures and logs particulate mass concentration, toxic gases, carbon dioxide (CO2), relative humidity, temperature, and air velocity

• Dial-in rotary impactor system for quick particulate selection

(PM2.5, PM4, PM10, or TSP)

• Built-in sampling pump collects particulates, while the lightscattering photometer mass concentration engine provides real-time measurement

• Photoionization detector measures volatile organic compounds (ppm)

Models for Sale

Description Catalog No Price

Basic Environmental Monitor EVM-7 $7531.00

Environmental Monitor + CO Sensor EVM-7/CO 7758.00

Rent by the day, week, or month.

See page 578.

Ships with base model with PID sensor, CO2 sensor, CO

sensor, two 37mm gravimetric filter cassettes, 12 VDC universal power supply, USB cable, impactor grease, PID cleaning kit, 10-pack of pump protection filters, dust zero calibration filter assembly, toxic calibration adapter, user manual, and carrying case.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

513

D

ust

t

rak

™ DRX for Mass Concentration and Total PM Size

• Continuous real-time 90° light-scattering laser photometer

• Simultaneously measures size-segregated mass fraction concentrations

(PM1, PM2.5, respirable, PM10, and Total PM size fractions)

• Combines both particle cloud (total area) and single particle detection to achieve mass fraction measurements

• 5.7" (Desktop) or 3.5" (Handheld) VGA color touchscreen interface

Rent by the day, week, or month.

See page 578.

D

ust

t

rak

™ II for Mass Concentration of Aerosols

• Replaces retired TSI DustTrak model 8520

• Real-time single-channel 90° light-scattering laser photometer

• Measures mass concentrations of aerosols to PM1, PM2.5, PM10, or respirable size fractions

• 5.7" (Desktop) or 3.5" (Handheld) VGA color touchscreen interface

Rent by the day, week, or month.

See page 578.

All TSI products compatible with

T rak

P ro

™ data analysis software include the CD free! The latest

T rak

P ro

™ version is also available for download from www.TSI.com

D

ust

t

rak

™ 8535 Weatherproof Enclosure

• Environmental enclosure provides security and protection

• Comes with sampling inlet for use in windy conditions

• Water trap prevents precipitation from entering the instrument

• Extended -life batteries allow con tinuous, 24-hour operation

• Wireless radio modems and dipole antenna for field communications

Rent by the day, week, or month.

See page 578.

Models and Accessories for Sale

Description Catalog No Price

DustTrak II Desktop Particulate Monitor (Replaces retired 8520) 8530 $5865.00

DustTrak II Handheld Particulate Monitor 8532 5375.00

DustTrak DRX Desktop Particulate Monitor

DustTrak DRX Handheld Particulate Monitor

8533

8534

10500.00

9130.00

DustTrak II and DustTrak DRX Environmental Enclosure 8535 1515.00

DustTrak Enclosure Internal Battery System (Order Separately) 801807 595.00

DustTrak Enclosure Heat Shield (Order Separately) 801810 150.00

Due to contract restrictions,

TSI DustTrak family products are only available for sale within our Midwest regional territory, but can be rented anywhere within the US.

DustTrak DRX includes analog outputs, rechargeable 6600 mAH Li-Ion battery, switching power supply with universal line cords, TrakPro data

analysis software, zero filter, USB computer cables, analog/alarm output connector, two inlet caps, 37mm cassette with mesh filter, 10mm nylon

Dorr-Oliver cyclone, impactor kit, two impactor plates, impactor oil, sample extension tube, four sheath air HEPA filters, filter removal tool, carrying case, operation service manual, calibration certificate, and two-year warranty.

DustTrak II ships with analog outputs, rechargeable 6600 mAH Li-Ion battery, switching power supply with universal line cords, TrakPro data

analysis software, zero filter, USB computer cables, analog/alarm output connector, two inlet caps, 37mm cassette with mesh filter, 10mm nylon

Dorr-Oliver cyclone, impactor kit, two impactor plates, impactor oil, sample extension tube, four sheath air HEPA filters, filter removal tool, carrying case, operation service manual, calibration certificate, and two-year warranty.

8535 enclosure includes weatherproof case with survey tripod mount, 360° sampling inlet with extended rain cap, water trap bottle, internal

equipment bracket with Velcro straps, dust caps, tubing, plug, O-rings, and weatherproof power adapter.

Using DustTraks for Perimeter Monitoring?

RAECO can help! Just call!

Let us know what your application needs are, and we'll help configure and build you a kit for perimeter dust monitoring that include the monitor, weatherproof case, battery power, a cellular modem with datalogging, weather station, and Internet cloudbased access to your results. Need to monitor area sound levels or VOCs? We can add that, too!

514

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Portable Aerosol and Airborne Particle Counters

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

s

iDe

P

ak

™ AM510 Intrinsically Safe Personal Aerosol Monitor

• Displays and logs real-time aerosol concentrations and 8-hour TWAs

• Built-in impactors for none, 1.0, 2.5, or 10-pM cutoff

• Built-in pump for use with variety of inlet conditioners

• Smart battery system with NiMH or AA battery pack

• Locking keypad prevents tampering or accidental changes

Ships with soft single-unit carrying case, 115/230 VAC power supply/charger, line power cord, impactor kit,

cyclone kit, screwdriver, T rak

P ro

™ data analysis software CD, USB cable, zero filter, sample tube, user guide, battery maintenance card, and quick reference card.

Rent by the day, week, or month.

See page 578.

Models and Accessories for Sale

Description

SidePak AM510 Personal Aerosol Monitor: One-Unit Kit

Kit with 6-Cell AA Battery Pack

CSA/ATEX Approved Kit, 1650 mAh NiMH Battery Pack

Kit with 2700 mAh NiMH Battery Pack

AM510 Replacement 10mm Nylon Dorr-Oliver Cyclone Kit

AM510 Replacement Impactor Kit (1.0, 2.5, 10 pM)

Catalog No Price

AM510-1A11 $4135.00

AM510-1C11 4240.00

AM510-1E11 4340.00

801701

801702

105.00

120.00

Due to contract restrictions,

TSI SidePaK AM510 aerosol monitors are only available for sale within our Midwest regional territory, but can be rented anywhere within the US.

a

ero

t

rak

™ Handheld Optical Particle Counters

• Three channel model (left) logs up to 1,500 samples, 0.3 to 25 mm range and user-selectable middle channel for 0.5, 1.0, 2.0, or 2.5

mm

• Six channel model (right) logs up to 10,000 samples, size range from

0.3

mm to 10mm, factory-calibrated at 0.3, 0.5, 1, 3, 5, and 10mm, and includes an internal audible alarm

• Color touchscreen operation and straightforward control with Windows

CE operating system and TSI TrakPro™ Lite data download software

Rent by the day, week, or month.

See page 578.

Models and Accessories for Sale

Description Catalog No Price

Three-Channel Handheld Airborne Particle Counter, Flow Rate 0.1 CFM (2.83 LPM)

0.3/5.0 mm Fixed, 0.5/1.0/2.0/2.5 mm Selectable Middle Channel

9303-01 $2195.00

Six-Channel Handheld Airborne Particle Counter, Flow Rate 0.1 CFM (2.83 LPM)

Six Fixed Channels: 0.3/0.5/0.7/1.0/2.0/5.0 mm

Six Fixed Channels: 0.3/0.5/1.0/3.0/5.0/10 mm

Six Selectable Channels: 0.3 to 10 mm, (Replaced retired 8220)

Calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, and 10.0 mm

9306-03 3945.00

9306-04 3945.00

9306-V2 3995.00

Units ship with power supply,

rechargeable Lithium Ion battery, isokinetic inlet, purge filter, USB cable, and TrakPro Lite download software. 9306 units also ship with stylus. Call for optional accessories:

Spare batteries, sample tubing, temperature/RH probe, printer and paper, and carrying case.

Portable and personal dust monitors reduce employee exposure risks

A customer at a large welding operation saw visible smoke on the plant floor during operation, so they needed to address both potential hexavalent chrome and total respirable dust exposure. They decided to use the TSI DustTrak II for area monitoring, and employees started wearing AM510s for personal monitoring.

The TSI devices were used to characterize the environmental and breathing area particulate concentrations, and to evaluate strategies to control ventilation and reduce exposure. With data from the DustTrak II and AM510s, the customer was able to select the most effective and energy efficient solution for reducing employee exposures.

Later, IH sampling confirmed dramatic reductions in both chrome and respirable dust exposure. Plus, employees reported being more comfortable in their environment.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

515

Particulate Concentration Monitors for Plant Safety

P-t

rak

® 8525 Ultrafine Particle Counter

• Counts ultrafine particles less than 1 mm diameter

• Tracks unwanted particles to their source in real time

• Logs data up to 1000 hours at minute intervals, holds 141 tests at once; Download data to a PC for record-keeping and analysis

• Ideal for checking filters and finding gasket leaks

Models and Accessories for Sale

Description

P-Trak Ultrafine Particle Counter, 20-1000 nm

Catalog No

8525

Price

$5805.00

Replacement Alcohol Wicks with Screens (10-Pack)

Replacement 30 ml Alcohol Bottles (Case of 16)

Replacement Hard-Sided Carrying Case

8023

8016

801613

135.00

115.00

225.00

P-T rak

® 8525 kit includes sample probe, sample tube, shoulder strap, inlet screen, two spare wicks, bat-

tery holder, six AA batteries, alcohol fill capsule and storage cap, alcohol cartridge, four 30ml bottles isopropyl alcohol, two zero filters, carrying case, T rak

P ro

software, USB cable, DB9/DB25 serial adapter, and manual.

Rent by the day, week, or month.

See page 578.

Due to contract restrictions, the TSI P-Trak 8525 is only available for sale within our

Midwest regional territory

(though parts are available for unrestricted sale). The

P-Trak can be rented anywhere within the US.

a

ero

t

rak

™ Portable Airborne Particle Counters

• Six-channel benchtop particle counters with 1 CFM or 50 LPM flow rates, available in 0.3 or 0.5 to 25 mm ranges

• Store up to 10,000 sample records and download by USB or Ethernet, or print directly from built-in thermal printer

• 5.7" Windows CE-based color touchscreen TSI's TrakPro™ Lite data download software

Units ship with power cord, battery, stainless steel isokinetic probe, tripod 10' sampling tube, purge filter,

printer paper, USB cable, TrakPro Lite data download software. Call for pricing on other accessories.

Need a fieldmount particle counter? Call

RAECO.

Models and Accessories for Sale

Description Catalog No Price

Six-Channel Particle Counter (0.3/0.5/1.0/3.0/5.0/10 mm), 1 CFM

Six-Channel Particle Counter (0.5/0.7/1.0/3.0/5.0/10 mm), 1 CFM

9310-02

9510-02

$8995.00

8770.00

Six-Channel Particle Counter (0.3/0.5/1.0/3.0/5.0/10 mm), 50 LPM

9350-02 9890.00

Six-Channel Particle Counter (0.5/0.7/1.0/3.0/5.0/10 mm), 50 LPM

9550-02 9585.00

a

ero

t

rak

™ 9000 Nanoparticle Aerosol Monitor

• Indicates lung surface area of nanoparticles in the TB and A regions

• Integrated pump for active sampling; 1 µm cyclone at 2.5 lpm

• Statistics for 8-hour TWA, min/max/average surface area concentration with alarm setpoint for workplace exposure monitoring

• Graphs real-time data or logged sample data up to one million points

• Stainless steel case for use in clean rooms

Due to contract restrictions, the TSI AeroTrak 9000 is only available for sale within our

Midwest regional territory

(though parts are available for unrestricted sale).

Models and Accessories for Sale

Description

AeroTrak 9000 Nanoparticle Aerosol Monitor

6600 mAH Lithium Ion Battery

Two-Bay Battery Charger for AeroTrak 9000/8240/8260

Replacement Filter Maintenance Kit

Catalog No

9000

1208057

2610114

1031599

Price

CALL

375.00

730.00

445.00

Kit includes carrying case,

6600 mAH rechargeable Lithium

Ion battery, 1

mm cyclone, filter

maintenance kit (one each HEPA, carbon, and conductive filters),

USB cable, analog/alarm output cable, conductive sampling tube, power cord, 9/16" cyclone wrench, dual-ended screwdriver, T rak

P ro

™ software CD, and user guide.

516

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Portable Ventilation Test Instruments

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

V

eloci

c

alc

™ 9565 Multifunction Ventilation Meter

• Velocity range from 0 to 15,000 ft/min, measures velocity by thermal sensor, rotating vane, or Pitot tube

• Calculates air and heat flow, turbulence, wet bulb, dewpoint temperature; displays up to five measurements simultaneously

• Datalogging capacity of more than 26,500 samples and 100 test IDs

• Works with TSI TrakPro software for data download and analysis

Rent by the day, week, or month.

See page 580.

Models and Accessories for Sale

Description

VelociCalc™ ventilation meter, pressure, datalogging, 964 probe

VelociCalc ventilation meter, pressure, datalogging, 966 probe

VelociCalc ventilation meter, pressure, datalogging, no probes

VelociCalc ventilation meter, datalogging, no probes

IAQ probe: CO2, temperature, humidity, CO

Air velocity probe: Straight, velocity, temperature

Air velocity probe: Straight, velocity, temperature, humidity

Surface temperature probe

Volatile organic compound (VOC) probe, ppm range

IAQ, VOC (ppb), CO2, temperature and humidity probe

Rotating vane probe, 100mm, velocity, temperature

Catalog No Price

9565

9565-A

9565-P

9565-X

$2240.00

2410.00

1360.00

1145.00

982

960

964

792

985

986

995

2040.00

695.00

910.00

150.00

2390.00

3740.00

585.00

Kits includes meter, specified

probe, hard carrying case, four

AA Alkaline batteries, USB cable,

LogDat2 and TrakPro software, user manual, calibration certificate. 9565, 9565-A, and

9565-P include one 8' rubber tube and static pressure tip.

V

eloci

c

alc

™ 9500 Series Ventilation Meters

• For HVAC system performance, commissioning, and plant maintenance

Velocity (ft/min)

Temperature (°F)

Relative humidity

Model 9515

0–4,000

0°–200°

Wet bulb, dewpoint

Variable time constant

Datalogging

9535

0–6,000

0°–200°

9545

0–6,000

14°–140°

0–95%

12700+ samples, 100 IDs

Models and Accessories for Sale

Description

Air velocity and temperature meter

Datalogging meter, straight probe, velocity, temperature

Datalogging meter, articulated probe, velocity, temperature

Datalogging meter, straight probe, velocity, temp., humidity

Datalogging meter, articulated probe, velocity, temp., humidity

Catalog No

9515

9535

9535-A

9545

9545-A

Price

$640.00

990.00

1150.00

1325.00

1485.00

9515 ships with instrument,

hard carrying case, four Alkaline batteries, operation and service manual, and calibration certificate.

TSI 9535 and 9545 include

instrument, hard carrying case, four Alkaline batteries,

USB cable, LogDat2 software, operation and service manual, and calibration certificate.

V

eloci

c

alc

™ 5725 Rotating Vane Anemometer

• Velocity range 50–6,000 feet per minute

• Reversible 4" head to read supply and exhaust flows

• Input duct shape, size, and area for volumetric flow rate calculation

• Sampling function records multiple point measurements, logs 12,700+ samples with time and date stamp

• Automatic averaging of air velocity; Displays velocity and temperature

Models and Accessories for Sale

Description

Rotating vane anemometer, datalogging

Aircone kit, 11.2" x 9.2" rectangular, 7.1" round

36" telescoping rod for rotating vane probe

Catalog No Price

5725 $835.00

801749

801748

240.00

150.00

Kit includes instrument with

4" (100mm) vane, carrying case

Alkaline batteries, operation and service manual, USB cable,

LogDat2 downloading software and calibration certificate.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

517

EBT731 Electronic Balancing Tool

• Measurement range: 25 to 2500 CFM

• Pre-assembled hood frames save on-site setup time

• Detachable manometer for use in other applications

• Use with Pitot, air flow, temperature, or relative humidity probes

• Datalogging and download software for easy report generation

• Add an air capture hood stand for one-person operation, use an

Android tablet and LogDat mobile to view data from across the room

Models and Accessories for Sale

Description

Electronic balancing tool with 2' x 2' hood and frame kit

18" air flow probe (25–5000 ft/min)

Temperature probe (-40° to 250°F)

Velocity matrix, telescoping handle (25–2500 ft/min)

Air capture hood stand

Optional

Hood Kits

2' x 4' hood kit

1' x 4' hood kit

3' x 3' hood kit

8" x 22" Class II biosafety cabinet hood kit

10" x 22" Class II biosafety cabinet hood kit

Catalog No Price

EBT731 $3165.00

800187

800220

801090

CH-STAND

385.00

360.00

390.00

485.00

801201

801200

801203

801204

801205

350.00

350.00

350.00

470.00

470.00

Rent by the day, week, or month.

See page 580.

Ships with base, 2' x 2' hood,

frame, and base, manometer, wheeled carrying case, 18" Pitot probe, two static pressure probes, temperature/humidity probe, two

8' Neoprene tubes, LogDat1 download software, serial interface cable, neck strap, four AA rechargeable NiMH batteries, charger, NIST calibration certificate, and user manual.

Capture Hood Stand Makes Ventilation Testing Easier!

• Reach ceiling diffusers and grilles up to 15 feet (with hood attached)

• Eliminates ladder use and movement — saves time and increases safety

• Get more measurements in less time — just roll the balometer to the next location

• Stand uses two wheels and casters for easy movement, with two extension poles for height adjustment

• Comes with soft-sided case and shoulder strap for easy portability

• Detach the digital manometer and connect it to the hood with two 8' sections of tubing to view results without climbing

• View your test data on a smart phone or tablet using TSI LogDat Mobile software (available from Google Play store) and compatible device (Android smart phone OS 2.3.3 or newer,

Nexus 7, Nexus 10, or Motorola Xoom tablets)

Order the CH-STAND with your EBT731 and download TSI LogDat Mobile from Google Play.

TSI Alnor 6200 LoFlo Balometer

• Measurement range 10 to 500 CFM

• Accuracy to ±3% + 5 CFM

• Analog display for air trends plus digital readings

• Multiple kits and hood sizes available: 16" square x 8" tall, 2' square x

8" tall, 16" square x 18" tall, or 26" square x 18" tall

• Ultra light weight for easy one-person operation

• Operates on four AA batteries, minimum 10 hours of continuous use

Models and Accessories for Sale

Description

LoFlo Balometer with 16" x 16" x 8" tall hood and frame kit

LoFlo Balometer with 2' x 2' x 8" tall hood and frame kit

Hood Kits 16" x 16" x 18" tall hood and frame kit

26" x 26" x 18" tall hood and frame kit

Catalog No

6200

6200D

634620085

634620130

Price

$1605.00

1595.00

245.00

245.00

Rent by the day, week, or month.

See page 580.

Includes base, hood, batteries,

carrying case, NIST calibration certificate, user manual, and two-year limited warranty.

518

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Portable Ventilation Test Instruments

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

PAN200 Positive and Negative Duct Accreditation System (PANDA)

• Find and fix duct leaks to save energy

• High flow fan for testing large duct sections

• Pressurizes duct quickly, so testing can begin in minutes

• Includes TSI VelociCalc 9565-P ventilation meter and DP-Calc 5815 micromanometer

• Automatically calculate leakage rate in real time

• Monitor barometric pressure and temperature to automatically correct to Standard

Temperature and Pressure (STP)

• Log data and download for easy report generation and documentation

Includes base unit, TSI VelociCalc 9565-P and DP-Calc 5815 plus low flow nozzle, primary duct adapter, .13-foot plastic flexible

duct, 20" and 16-foot silicone tubes, smoke cap holder assembly, smoke pellets, K-type thermocouple probe, instrument adapter, operation and user manual.

Pass/Fail Reporting for Standards

• SMACNA HVAC air duct leakage test

• EN12237, EN1507 ventilation for buildings

• EUROVENT 2/2 standards

Models and Accessories for Sale

Description

110V Powered duct leak tester, TSI 9565-P and 5815

110V Powered duct leak tester, no instruments

Smoke pellets, tube of 6

Catalog No Price

PAN231-110 $9780.00

PAN315-110 8750.00

AFL9004167 20.00

HM675 and HM685 Handheld Digital Hydronic Manometers

• Test and balance heating and cooling systems, check pump performance, set balancing valves

• Measure and display high side, low side, and differential pressure simultaneously from 0 to 300 PSI

• Inputs from two temperature probes

• Calculates flow using valve manufacturer's Cv factor, up to 100, Calculates heat flow, impeller diameter, and brake power

• HM685 stores up to 4000 data points for download using TSI CompuDat software and USB cable

Models and Accessories for Sale

Description Catalog No Price

Hydronic manometer

Datalogging hydronic manometer with download kit

HM675

HM685

$3105.00

3795.00

Accessory kit (34 fittings + 2 readout probes)

4" HM temperature probe

Accessories 6" HM temperature probe

6' temperature probe extension cable

HMFIT

801290

801291

801293

220.00

235.00

265.00

95.00

Ships with instrument and standard fittings, two 6' hoses, two ITT Bell & Gosset readout probes, two P/T

gauge adapter probes, four AA NiMH batteries, internal battery charger, NIST traceable calibration certificate,

hard carrying case, two-year limited warranty. HM685 also includes downloading software, USB computer

cable, and temperature probe.

Testo 550 Refrigeration System Analyzer

• Real-time superheat and subcooling calculations from 31 pre-configured refrigerant profiles

• Two NTC temperature probe inputs

• Accurate to 580 PSI, max pressures to 870 PSI

• Performs both timed pressure drop tests and standing pressure tests for commissioning systems

Models and Accessories for Sale

Description Catalog No Price

Basic refrigerant system analyzer kit, one probe

Deluxe refrigerant system analyzer kit, two probes, case

0563 5505

0563 5506

$299.00

399.00

Ships with instrument, NTC temperature probe, batteries, calibration certificate. Deluxe kit includes second

probe plus a hard-sided carrying case.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Indoor Air Quality Measurement Instruments

519

iaQ-c

alc

™ 7500 Series Indoor Air Quality Meters

• All models feature low-drift NDIR CO

2

sensor for accurate readings

• 7515/7535 units display CO2; 7525/7545 display up to three parameters

• 7525 and 7545 also measure temperature and relative humidity, calculate percent outside air from CO2 or temperature, and directly calculate dewpoint and wet bulb temperature

• Datalogging models include statistics function for average, maximum and minimum values, and number of recorded samples

Ships with instrument, four AA Alkaline batteries, hard carrying case, manual, NIST calibration certificate.

Datalogging models include LogDat software on CD and USB cable.

Rent by the day, week, or month.

See page 580.

Models and Accessories for Sale

Description

IAQ-Calc basic meter, CO2 measurement

IAQ-Calc meter, CO2, temperature, humidity, datalogging

IAQ-Calc meter, CO2, CO, temperature, humidity, datalogging

Catalog No

7515

7525

7545

Price

$620.00

1935.00

2215.00

Need calibration kits?

Call RAECO.

Q-t

rak

™ 7575 Indoor Air Quality Monitor

• Measures CO2, temperature, humidity, and CO, and displays up to five measurements simultaneously

• Calculates percent outside air from CO2 or temperature and automatically calculates dewpoint, and wet bulb temperature

• Store up to 38.9 days of data collected at one-minute log intervals

Q-T rak

™ 7575 ships with 982 IAQ probe, Alkaline batteries, USB cable, TrakPro software, AC adapter,

carrying case, user manual, calibration certificate, and two-year warranty.

Models and Accessories for Sale

Description

Q-Trak™ 7575 IAQ meter with IAQ probe 982

IAQ probe: CO2, temperature, humidity, CO (included)

Air velocity probe: Straight, velocity, temperature

Air velocity probe: Straight, velocity, temperature, humidity

Surface temperature probe

Volatile organic compound (VOC) probe, ppm range

IAQ, VOC (ppb), CO2, temperature and humidity probe

Rotating vane probe, 100mm, velocity, temperature

Catalog No

7575

982

960

964

792

985

986

995

Price

$3100.00

2040.00

695.00

910.00

150.00

2390.00

3740.00

585.00

Rent by the day, week, or month.

See page 580.

Due to contract restrictions, the TSI Q-Trak™ 7575 is only available for sale within our

Midwest regional territory

(though parts are available for unrestricted sale). The

Q-Trak can be rented anywhere within the US.

DP-c

alc

™ 5815 and 5825 Handheld Micromanometers

• Measures differential and static pressure from -15" to 15" H2O

• Calculates and displays velocity when used with a pitot tube

• Variable time constant for fluctuating flows

• 8525 also calculates flow, logs data with time/date stamp, stores 12,700+ samples and 100 test IDs, and supports programmable K factor

Models and Accessories for Sale

Description

Basic digital handheld micromanometer

Digital handheld micromanometer, datalogging, velocity calc.

18" Pitot probe, 5/16" diameter

Pitot Probes 24" Pitot probe, 5/16" diameter for 8525 36" Pitot probe, 5/16" diameter

8" to 38" telescoping Pitot probe

Catalog No

5815

5825

634634001

634634002

634634003

634634004

Price

$555.00

855.00

165.00

180.00

210.00

310.00

Ships with instrument, hard car-

rying case, four Alkaline batteries, operation and service manual, and calibration certificate. 8525 also includes one 8' rubber tube, one static pressure tip, LogDat2 downloading software and USB cable. Pitot probe ordered separately.

520

RAECO LIC-LLC www.RAECO.com [email protected]

Noise Dosimeters

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Edge eg4 and eg5 Personal Noise Dosimeters

• Cable-free dosimeter that displays SPL, dose, Lavg, Leq, TWA, maximum, minimum, and peak levels, and run time — all in RUN mode

• Convenient, efficient, cable-free design eliminates the microphone cable and its potential to get in your way

• Two virtual dosimeters plus datalogging for measuring 70 to 140 dB

• Independent dosimeter thresholds (70 to 90 dB or none), exchange rates

(3, 4, or 5 dB), and criterion levels (70 to 90 dB in 1 dB increments)

• Rechargeable battery provides more than 60 hours of run time

• Compatible with 3M Quest software for reporting, record-keeping, calibration management, exposure recalculation, and administrative/ engineering controls assessment

Rent by the day, week, or month.

See page 585.

Models and Accessories for Sale

Description

Edge eg4 general service personal cord-free noise dosimeter

Edge 4 noise dosimeter

Edge 4, EdgeDock-1 docking station

Edge 4, EdgeDock-1 docking station, AC-300 calibrator

Five Edge 4s, EdgeDock-5 docking station, AC-300 calibrator

Edge eg5 intrinsically safe personal cord-free noise dosimeter

Edge 5 noise dosimeter

Edge 5, EdgeDock-1 docking station

Edge 5, EdgeDock-1 docking station, AC-300 calibrator

Catalog No Price

eg4 eg4-D eg4-D-AC3

$1539.00

2008.00

2530.00

5eg4-D-AC3 8750.00

eg5 eg5-D eg5-D-AC3

1717.00

2186.00

2708.00

Single unit includes one do-

simeter, two windscreens, 1/4" microphone, calibrator adapter, user manual and carrying case.

EdgeDock-1 models include power supply and USB cable.

Five-pack includes five each:

dosimeters with 1/4" microphones, eight windscreens, plus one each:

EdgeDock-5 five-bay docking station with power supply, AC-300 calibrator and calibrator adapter,

USB cable, and carrying case.

AcoustiCal AC-300 Sound Calibrator

• Produces 250 Hz or 1000 Hz at a sound pressure level of 114 dB

• Calibrates Class/Type 1 and Class/Type 2 sound level meters and noise dosimeters; Meets ANSI and IEC standards

• Screen displays Hz, dB, and battery life

• 1" coupler opening with snap-in adapters for smaller connections

• Replacement for retired Quest QC-10 and QC-20 calibrators

Models and Accessories for Sale

Description

Sound calibrator, single output 114 dB at 1000 Hz

Calibrator adapter for 0.25" diameter microphones

Calibrator adapter for 0.5" diameter microphones

A-63B preamp adapter for 1" diameter microphones

Catalog No

AC-300

56-988

56-990

58-376

Price

$522.00

42.00

42.00

98.00

Due to contract restrictions,

3M Quest products are only available for sale within our

Midwest regional territory.

They can be rented anywhere within the US.

Includes calibrator, 9V battery,

calibration certificate, and user manual. Order adapter separately, based on microphone size.

Software for Analyzing Your Noise Dosimeter Results

Detection Management Software for reporting, record-keeping, calibration management, and more!

• Compatible with 3M Quest Edge and

NoisePro noise dosimeters, SoundPro and

Sound Examiner SE-400 sound level meters,

EVM series environmental monitors, and

QuesTemp heat stress monitors

• Imports legacy data from QuestSuite Pro software

• Display and manipulate data on your PC

• Download configuration files, parameter settings and clock

• Store calibration data and serial number

• Single user, 10-user, or unlimited licenses

• Call RAECO for pricing and latest version

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

521

NoisePro DL Type 2 Noise Dosimeters

• One or two virtual dosimeters in one

• Lavg/Leq, FastMax and SlowMax statistics; Displays time history, recalculated exposure data

• Alarms for Dosimeter #1 overall TWA value and any Dosimeter #1 time history interval Lavg/Leq

• Auto-run activators one-time, once or twice daily with weekday choice

• Minimum 40 hours time history capacity with all data saved

• Compatible with 3M Quest software

Single dosimeter kit includes dosimeter, Class 2 pendant microphone, windscreen, calibrator adapter, and storage case.

Additional components available as specified by model.

Five-pack kit includes five each of the following: NoisePro DL dosimeters, Type 2 pendant microphones, windscreens, micro-

phone cords, and clothing clips, plus one each of the following: AC-300 calibrator, IR to RS-232 PC interface cable, storage case.

Models and Accessories for Sale

Description

NoisePro DL noise dosimeter

NoisePro DL with IR/RS-232 computer interface cable

NoisePro DL, IR/RS-232 cable, AC-300 calibrator

5-Pack Kit, IR/RS-232 cable, AC-300 calibrator

RS-232 serial to USB adapter

Catalog No Price

NP-DL

NP-DL-CBL

NP-DL-AC3

$1957.00

2100.00

2479.00

5NP-DL-AC3 10643.00

53-810 100.00

Learn more about these products.

Check RAECO.com for specs, manuals, quick-start guides, application notes, how-to videos, and more.

Due to contract restrictions,

3M Quest products are only available for sale within our

Midwest regional territory.

They can be rented anywhere within the US.

NoisePro DLX Type 2 Noise Dosimeters

• Up to four virtual dosimeters in one

• Time history statistics per dosimeter: Lavg/Leq, FastMax and SlowMax, FastMin,

SlowMin, fast and slow ceiling counts, Lpeak; Turn off any statistic as needed

• Alarms for Dosimeter #1 overall TWA value and any Dosimeter #1 time history interval Lavg/Leq

• Stores data from up to five dosimeters in series; Download statistics, statistical distribution, time history, and recalculated exposure data

• Auto-run activators up to four one-time runs, once or twice daily

• Compatible with 3M Quest software

Models and Accessories for Sale

Description

NoisePro DLX noise dosimeter

NoisePro DLX with IR/RS-232 computer interface cable

NoisePro DLX, IR/RS-232 cable, AC-300 calibrator

5-Pack Kit, IR/RS-232 cable, AC-300 calibrator

RS-232 serial to USB adapter

Catalog No

NP-DLX

NP-DLX-CBL

NP-DLX-AC3

Price

$2353.00

3738.00

4117.00

5NP-DLX-AC3 12623.00

53-810 100.00

Rent by the day, week, or month.

See page 585.

Single meter kit includes

dosimeter, Class 2 pendant microphone, windscreen, calibrator adapter, and storage case. Additional components available as specified by model.

Five-pack kit includes five

each of the following: NoisePro DL dosimeters, Type 2 pendant microphones, windscreens, microphone cords, and clothing clips, plus one each of the following: AC-300 calibrator, IR to RS-232 PC interface cable, storage case.

NI-100 Personal Noise Indicator

• Alerts users to potentially dangers noise levels and helps identify areas where hearing protection needs to be worn

• Accurate to 3 dB

• LED flashes green when noise levels are below 85 dBA. Flashes red when noise levels are over 85 dBA, indication the need for hearing protection

• Rechargeable battery operates up to 200 hours between charges

• Auto power-off after 10 hours to save battery life

Order a 10-pack

P/N: NI-100

Price: $445.00

10-pack includes case of 10

indicators, user instructions.

522

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Portable Sound Level Meters

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

SD-200 Sound Detector Integrating Sound Level Meter

• 45 to 130 dB dynamic range with 3 or 5 dB exchange rate

• LED alert levels: Flashing green at 80 to 85 dB, flashing yellow at 85 to 105 dB, flashing red at >105 dB

• Measures SPL, Min, Max, Leq, Lavg, runtime overload, and under range

• Bright display has 3/4" digits, 0.1 dB resolution, 0.5 second update rate

• Acoustic standards: ANSI S1.4 1983 (R2006), ANSI S1.43 1997 (R2007), IEC

61672-1 (2002) and IEC 61010-1 (2010)

Models and Accessories for Sale

Description

Sound Detector Sound Level Meter

0.5" Calibration Adapter for SD-200 and AcoustiCal

Catalog No

SD-200

56-990

Price

$369.00

42.00

Kits include sound detector,

Type 2 microphone, USB cable (for charging via PC), windscreen, user instruction manual.

Sound Examiner Type 1 and Type 2 Integrating Sound Level Meter

• 30 to 140 dBA overall range, 100 dBA total dynamic measurement range, 143 dBA max sampled peak level; Three selectable exchange rates: 3, 4, and 5 dBA

• Choice of Type 1 (precision) or Type 2 (general purpose) microphones

• A, C, and Z peak frequency weighing

• SPL, Lmax, Lmin, peak, Leq/Lavg, and elapsed time

• 2MB internal memory for logged data, logging intervals from 5 seconds to 60 minutes

• USB interface for charging and connecting to PC and Detection Management Software

• Acoustic standards: IEC 61672-1 (2002), ANSI S1.43-1997 (R2007)

Models and Accessories for Sale

Description Catalog No Price

Sound Examiner with Type/Class 2 Microphone SE-402 $1517.00

Sound Examiner, Type/Class 2 Microphone, AC-300 Calibrator SE-402-AC3 2039.00

Sound Examiner with Type/Class 1 Microphone SE-401 2532.00

Sound Examiner, Type/Class 1 Microphone, AC-300 Calibrator SE-401-AC3 3054.00

Kits include meter, microphone,

USB cable, USB power supply, wind screen, calibrator adapter, storage case, and user instruction manual.

Calibrator included in kit if -AC3 is ordered.

SoundPro DL Datalogging Type 2 Sound Level Meter

• Acoustic standards: EN/IEC 61672, ANSI S1.4-1983, ANSI S1.43/1997, EC/IEC

61260, ANSI S1.11-2004, IEC 60651, and IEC 60804

• Measures SPL, Max, Min, Peak, Ln, Leq, Lavg, Sel, TWA, Taktm, Dose, PDose,

Ldn, CNEL, and exposure

• Class 2 frequency models with 1/1 or 1/3 octave band filters

• Datalogging capacity determined by logging interval and SD media

Rent by the day, week, or month.

See page 585.

Models and Accessories for Sale

Description Catalog No Price

SoundPro DL datalogging sound level meter

SoundPro DL with AC-300 calibrator

SoundPro DL with 1/1 octave real-time analyzer

SoundPro DL, 1/1 octave real-time analyzer, AC-300

SP-DL-2

SP-DL-2-AC3

SP-DL-2-1/1

SP-DL-2-1/1-AC3

$2615.00

3137.00

3732.00

4254.00

SoundPro DL 1/1 and 1/3 octave real-time analyzers SP-DL-2-1/3 4342.00

SoundPro DL, 1/1 and 1/3 octave real-time analyzer, AC-300 SP-DL-2-1/3-AC3 5364.00

Kits include meter, wrist strap,

windscreen, calibrator adapter,

USB cable, SD memory card, carrying case, 0.5" QE7052 microphone.

Some models noted below also include AC-300 calibrator and 1/1 or 1/3 octave real-time analyzers.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

523

Personal Sampling Pumps for Any Flow Range

Which Gilian Personal Sampling Pump is Right for You?

Flow range high Flow

Low/Constant

Flow

Display Data

Approvals battery Type

Charging Time

Max. Pressure

0.35 LPM

0.75 LPM

1 LPM

2 LPM

2.5 LPM

3 LPM

3.5 LPM

4 LPM

5 LPM gilAir Plus

1–5,500 cc/min

450–5,000 cc/min

0.5–5.0 LPM

20-449 cc/min

No module needed

Flow rate, sample time, battery level, actual/predicted run time, sampling mode, time and date, sample volume in actual conditions

FM, CE/ATEX, IECEx

Rechargeable 4.8V NiMH

Fault*

<3.5 Hours

8 hour run**

25" H2O 25" H2O

40" H2O

40" H2O

40 "H2O

37" H2O

35" H2O

32" H2O

30" H2O

15" H2O

40" H2O

35" H2O

30" H2O

30" H2O

30" H2O

25" H2O

20" H2O

12" H2O

gilian 5000

20–5,000 cc/min

800–5,000 cc/min

0.8–5.0 LPM

Live flow rate, total sample time, total volume sampled, and low battery

FM, CE/ATEX, FMC

Rechargeable 7.2V NiMH

Fault

<4 Hours

8 hour run

70" H2O

60" H2O

70" H2O

60" H2O

50" H2O

50" H2O

30" H2O

30" H2O

24" H2O

50" H2O

50" H2O

30" H2O

30" H2O

20" H2O

gilAir-3

1–3,000 cc/min

850–3,000 cc/min

0.75–3.0 LPM

gilAir-5

1–5,000 cc/min

850–5,000 cc/min

0.75–5.0 LPM

20–500 cc/min to 25" H2O (6.2 kPa)

Elapsed time (clock and timer models), low battery, flow fault

UL, CE/ATEX

Rechargeable 4.8V NiCd Rechargeable 6V NiCd

Fault

14–16 Hours

8 hour run Fault 8 hour run

30" H2O

20" H2O

20" H2O

10" H2O

25" H2O

15" H2O

15" H2O

8" H2O

37" H2O

37" H2O

32" H2O

32" H2O

20" H2O

20" H2O

18" H2O

29" H2O

26" H2O

23" H2O

23" H2O

18" H2O

18" H2O

8" H2O

Gilian 5000 5-Liter Live Flow Air Sampling Pump

• Backflow pressures from 20" H2O at 5 LPM to 70" H2O at 1 LPM

• Flow range: 20–5000 cc/min total, 800–5,000 cc/min high flow, 20–800 cc/min with low flow adapter installed

• Compensates for changes in flow rate, pressure, and temperature

• Four stage program with repeat cycle allows sample scheduling or intermittent duty cycles

• Intrinsically safe FM Class I, Div 1, Groups A–D, Class II, Div 1, Groups

E–G, Class III, T4; ATEX, CE approvals, plus EN 1232 compliant

Rent by the day, week, or month.

See page 581.

Models and Accessories for Sale

Description

Gilian 5000 basic pump kit, UL/ATEX

Gilian 5000 starter kit, UL/ATEX

Gilian 5000 starter kit, UL/ATEX, five-pump pack

Low flow adapter, 25–750 cc/min

Fixed mount assembly for low flow adapter

Replacement filters, 10-pack

Catalog No Price

810-0801-01 $882.00

910-0802-01 922.00

910-0801-01 4831.00

801961

801980

811-0012-01

94.50

144.50

19.00

Basic kit comes with pump, 36"

tubing, and user manual.

Starter

kit comes with pump, single unit

charger, filter cassette holder, 36" tubing, and user manual.

5-Pack

starter kit comes with five

each: pumps, filter cassette holders,

36" tubing lengths, user manuals, plus one 5-unit power station, and one carrying case.

524

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Personal Sampling Pumps for Any Flow Range

GilAir Plus 5-Liter Universal Air Sampling Pump

• Constant flow 25-5000 cc/min, constant pressure 1-5000 cc/min

• No adapter needed for high-flow and low-flow constant pressure, constant flow

• Up to 40” H2O back pressure in high flow, up to 25” H2O in low flow

• Automatically performs restart to recover from temporary faults

• Dock provides charging plus communication to PC or calibrator

• STP model corrects flow rate for standard temperature and pressure

• Battery proven to last 12 hours on a single charge

Rent by the day, week, or month.

See page 581.

Models and Accessories for Sale

Description

GilAir Plus single basic pump kit

GilAir Plus single datalogging pump kit

GilAir Plus single STP pump kit

GilAir Plus five-pack basic pump kit

GilAir Plus five-pack datalogging pump kit

GilAir Plus five-pack STP pump kit

SmartCal calibration cable for GilAir Plus and Gilibrator

SmartCal calibration cable for GilAir Plus and Challenger

SmartCal calibration cable for GilAir Plus and TSI 4146

Catalog No Price

910-0901-US-R $999.00

910-0902-US-R 1075.00

910-0903-US-R 1296.00

910-0904-US-R 5298.00

910-0905-US-R 5370.00

910-0906-US-R 6445.00

780-0015-01-R 102.00

780-0015-02-R 84.00

780-0015-03-R 89.00

Single kit includes one sam-

pling pump, single communication/charging dock, USB cable,

AC power supply, filter cassette holder, charcoal tube holder, software, hex wrench, and user manual.

5-Pack kit includes five each:

sampling pump, filter cassette holder, charcoal tube holder, certificate of performance plus one each: five-station communication/charging dock, AC power supply, hex wrench, software, and user manual.

Gilian GilAir-3 3-Liter Constant Flow Sampling Pump

• Constant flow: 750 to 3,000 cc/min; Low flow: 1 to 750 cc/min

• Built-in rotameter and flow adjuster

• UL listed intrinsically safe, MSHA, CE, and SIRA approved

• Multiple sorbent tube capability

Models for Sale

Description

GilAir-3 R (basic) pump, basic kit, UL/ATEX

GilAir-3 RC (clock) pump, basic kit, UL/ATEX

GilAir-3 RP (programmable) pump, basic kit, UL/ATEX

GilAir-3 R (basic) pump starter kit, UL/ATEX

GilAir-3 RC (clock) pump starter kit, UL/ATEX

GilAir-3 RP (programmable) pump starter kit, UL/ATEX

Catalog No

800485-171

800508-171

800510-171

Price

$626.50

768.50

794.00

800485-171-1201 688.50

800508-171-1201 829.50

800510-171-1201 863.00

Basic kit comes with pump,

36" tubing, air boss kit, reversible screwdriver, and user manual.

Starter kit comes with pump,

single unit charger, filter cassette holder, 36" tubing, air boss kit, reversible screwdriver, and user manual. Order low flow

adapter separately.

Gilian GilAir-5 5-Liter Constant Flow Sampling Pump

• Constant flow: 750 to 5,000 cc/min; Low flow: 20 to 500 cc/min

• Performs filter cassette, single, and multiple sorbent tube sampling

• Built-in rotameter, flow adjuster, and programmable timing options

• Flow Fault indicator lights if unit operates outside 5% of set flow rate

• Battery indicator lights when unit can operate eight hours within range

Rent by the day, week, or month.

See page 581.

Models for Sale

Description

GilAir-5 R (basic) pump, basic kit, UL/ATEX

GilAir-5 RC (clock) pump, basic kit, UL/ATEX

GilAir-5 RP (programmable) pump, basic kit, UL/ATEX

GilAir-5 R (basic) pump starter kit, UL/ATEX

GilAir-5 RC (clock) pump starter kit, UL/ATEX

GilAir-5 RP (programmable) pump starter kit, UL/ATEX

Catalog No

800883-171

800885-171

800884-171

Price

$710.00

828.50

866.00

800883-171-1201 761.50

800885-171-1201 901.00

800884-171-1201 937.50

Basic kit comes with pump,

36" tubing, air boss kit, reversible screwdriver, and user manual.

Starter kit comes with pump,

single unit charger, filter cassette holder, 36" tubing, air boss kit, reversible screwdriver, and user manual. Order low flow

adapter separately.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

525

Sampling Pump Calibrators and Accessories

Gilian Gilibrator 2 Deluxe Calibration Kit

• Primary standard accuracy and performance validation

• Interchangeable wet cells for standard, low, and high flow

• Microprocessor base LCD screen displays flow rate, calculated average of multiple flow samples in a series, and sample number

• PC interface kit for data download via RS-232 port

Models and Accessories for Sale

Description

Gilibrator-2 Deluxe kit, three flow cells, no printer

Gilibrator-2 Standard flow kit, 20–6000 cc/min

Gilibrator-2 Low flow kit, 1–250 cc/min

Gilibrator-2 High flow kit, 2–30 LPM

Replacement 120V battery pack for Gilibrator-2

120V single battery charger

Catalog No

801804

800271

800272

800270

700560

401984

Price

$2304.00

1309.00

1330.50

1453.00

68.50

34.00

Kits include control unit, battery

charger, carrying case, manual, specified wet cells, plus tubing, soap solution, and dispenser.

Gilian Challenger Precision Air Flow Calibrator

• Precise air flow calibration from 1 to 30 LPM

• Wide temperature range from -22° to 131° F

• Displays both actual and standard flow rates, accurate to ±0.75 reading

• Provides 90% recovery of pressure drop — key to reliable calibration

• Powered by four AA Alkaline batteries for 20+ hour runtime

Rent by the day, week, or month.

See page 581.

Models and Accessories for Sale

Description

Challenger air flow calibrator kit, 1–30 LPM

Challenger o-ring replacement kit

Catalog No Price

811-9911-03 $1655.00

811-9913-01 4.50

Kits include unit, venturi for

high and low flow calibration, four AA batteries, 18" tubing,

CD software, NIST certificate of calibration and traceability, and user manual.

Sample Pump Accessories for Sale

Description

Cyclone assembly (10 mm Nylon Dorr-Oliver)

Cyclone sampler calibration jar

Luer taper adapter (6-pack)

Filter cassette kit (required when sampling with cassette)

50-pack MCE filter cassette, 0.8 mm pore, 37mm diam.

Low flow module for GilAir-3/GilAir-5 20–500 cc/min

Filter replacement pack (100/package) for GilAir-3/GilAir-5

Catalog No

800061

7013376

200156-6

800143

GCU37080

800518

201050-100

Price

$103.00

58.00

22.00

31.50

76.50

130.00

96.50

4046 and 4146 Primary Flow Calibrator Kits

• Continuous real-time readings for pump adjustment and calibration

• Flow range 0.01 to 20 or 2.5 to 300 liters per minute

• Battery powered, compact, light weight

Models and Accessories for Sale

Description Catalog No Price

Primary flow calibrator model, 0.01–20 LPM

Primary flow calibrator model, 2.5–300 LPM

4146

4046

$1125.00

1370.00

Replacement flowmeter battery pack 4199 110.00

Kits include flow calibrator unit, battery pack, connector kit, carrying case, six AA Alkaline batteries, con-

nectors, tubing, battery pack lugs, two-year warranty, user guide, NIST calibration certificate. 4146 also comes with dampening chamber module.

Rent by the day, week, or month.

See page 581.

526

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Digital Instrumentation for Thermal and Optical Testing

Testo Thermal Imagers with Built-In Digital Cameras

Model

Use

Measurement points

Detector size

4X Super

Resolution

LCD size

Thermal sensitivity

Spectral range

Focus

Testo 875

For commercial diagnostic measurement

19,200

160x120 pixel

320x240 pixels

3.5" screen

80 or 50 mK NETD

Manual

Testo 882

For commercial and industrial diagnostics

76,800

320x240 pixel

640x480 pixel

Testo 885

For commercial, industrial, and research use

76,800

320x240 pixel

640x480 pixel

Testo 890

For industrial and research applications

307,200

640x480 pixel

1280x960 pixel

3.5" screen

50 mK NETD

8-14 μm

Manual and motorized

4.3" touchscreen

30 mK NETD

4.3" touchscreen

40 mK NETD

Manual and automatic

Testo thermal imagers quickly and reliably detect anomalies, weak spots, and damage in industrial maintenance, production monitoring, and in research and development applications.

• Regular checks in electrical maintenance

• Support in preventive mechanical maintenance

• Quick, easy fluid level checks

• Safer high temperature measurements

• Consistent reliability in quality assurance and production monitoring

Materials and components can be tested completely without damage using thermal imaging technology. Problem zones can be identified without contact before a malfunction or fire risk occurs.

• Preventive maintenance for power applications

• Precise visualization of critical temperatures in microelectronics

• Quality control in the production of diecast plastic components

• Monitoring and checking solar energy systems

• Analysis of electrical distribution systems

• Inspection management in large manufacturing

Models and Accessories for Sale

Description

875i-2 Deluxe thermal imager kit

882 Thermal imager kit

875/882 Lens protection glass

Accessories Protective sun shield

4X Super Resolution

885-2 Deluxe thermal imager kit

890-2 Deluxe thermal imager kit

Catalog No

0563 0875 73 $5395.00

0560 0882 70 7495.00

0554 8805

0554 8814

0554 7806

Price

506.00

183.00

395.00

0563 0885 73 12995.00

0563 0890 73 21995.00

885/890 Lens protection glass

Accessories 4X Super Resolution

0554 0289

0554 7806

809.00

395.00

Deluxe kits include instrument with integrated digital camera, telephoto lens, protective lens, two-bay

battery charger, spare battery, and protective sunshield with shoulder strap, hard shell carrying case, SD card,

USB cable, power supply, and tripod mounting plate.

Standard kits (882) include a hard shelled case, SD card, USB cable, software, power supply, and tripod mounting plate.

Due to contract restrictions,

Testo products are only available for sale within our

Midwest regional territory.

They can be rented anywhere within the US.

SAFETY INSTRuMENTS — poRTAblE

Products in this catalog are available to rent anywhere in the US. Due to representative agreements with our manufacturer partners, not all products are available for sale in all areas and markets.

527

Delivery and training available only in Illinois, Indiana, Wisconsin, Kentucky, and Eastern Iowa.

Prices are current at publication, and are subject to change without notice.

See

Page

Emissions Monitoring

Testo 310/320 Residential/Commercial Combustion Analyzers

Testo 330-2G LL Industrial Combustion Analyzer

Testo 340 Portable Combustion Tuning Analyzer

Testo 350 Portable Combustion Efficiency Analyzer

540

540

541

542

Respirator Fit Testing Systems

TSI QFit OSHA-Approved Qualitative Respirator Fit Tester

TSI MITA 8120 Mask Integrity Test Accessory

TSI P orta

C ount

P ro

Quantitative Respirator Fit Testers

TSI P orta

C ount

Family Respirator Adapter Kits and Accessories

Gas Detection and Monitoring

BW Technologies GasAlert Extreme Single Gas Detectors

BW Technologies GasAlert Max XT II Four-Gas Monitor

BW Technologies GasAlert Quattro Personal Multigas Monitor

BW Technologies GasAlert Micro5 Five-Gas Detectors with PID

BW Technologies MicroDock II Calibration and Bump Test System

Enmet Formaldemeter htV Airborne Formaldehyde Meter

Gasmet DX4040 Portable FTIR Ambient Gas Analyzer

Ion Science Photoionization Detectors (PIDs) for VOC Detection

Ion Science Portable Mercury Vapor Monitor

Ion Science GasCheck Intrinsically Safe Handheld Gas Leak Detector

Morphix Technologies Direct-Read Passive Monitoring Badges

Photovac Inficon Portable Flame Ionization Detector (FID)

Sensidyne AP-20S Gas Detection Pump and Detector Tubes

Heat Stress Monitoring

3M Quest Portable Area Heat Stress Monitors

3M Quest Personal Heat Stress Monitor

528

530

529

531

538

534

534

532

539

533

535

536

536

537

535

534

539

544

544

Looking for Training for Your Portable Instruments?

Online Training

Need to learn how to perform fit tests with a TSI PortaCount system? Having trouble figuring out how to get data from your BW

Technologies gas monitors or 3M Quest noise and sound meters?

The answers are as close as our Online Training Center. In just five minutes, you'll get a step-by-step tutorial on how to load data analysis software on your PC, connect your instrument to a PC, transfer data, and view it in the manufacturer's software.

TSI has provided us with a full series of video clips for respirator fit testing, from basic introductions, to setup, to standard exercises and tips to make the PortaCount systems work best for you.

Best yet, they're all available for FREE. Just visit www.Raeco.com

and click on the Training Center link in the toolbar.

A Note About Calibration Gases

Because of their classification as hazardous materials, calibration gases are not included with any of our instruments. You can contact RAECO to order them separately. All calibration gas orders will be subject to handling charges and HazMat shipping fees.

528

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Q

fit

™ OSHA-Approved Qualitative Respirator Fit Tester

Features

• Only OSHA-approved automated nebulizer for Bitrex® and Saccharin

• For half-face, tight-fitting elastomeric respirators, Series-95, P1, and P2 filtering facepiece respirators

• Eliminates repetitive stress disorders

• Pre-filled cartridges reduce mess and handling of solutions

• Lightweight, portable, battery operated

• Generates a consistent test agent with pump-driven nebulizer

• Reduces clogging of saccharin solution

• Interactive training CD available for initial and follow-up training

TSI’s Qfit respirator is the only OSHA-approved (29CFR 1910-134) automated pump-driven nebulizer for Bitrex and Saccharin, to qualitatively test the integrity of respirators. The Qfit uses pre-filled cartridges, eliminating the nuisance of mixing, handling, and refilling solutions.

At the push of a button, the Qfit fit tester generates a consistent test agent. Removing hand aspiration from the equation increases test reliability, since no two squeeze bulb tests can be guaranteed to be conducted the same. The pump-driven nebulizer also eliminates the repetitive stress disorders associated with using squeeze-bulb nebulizers.

Qfit comes in two versions: automatic and manual. Both replace the need to repetitively handaspirate a rubber squeeze bulb, by using an integral pump to disperse sensitivity and fit test solutions, and both work in either handheld or remote modes. The automatic version features a built-in timing sequence that automatically executes the fit test protocol. The manual version requires you to control the device manually to complete the test.

Traditional qualitative fit testing procedures that use a hand-aspirated squeeze bulb nebulizer can require anywhere from 85 to 255 pump strokes to complete sensitivity and fit tests on just one employee. So, if an employee passes a 10-stroke sensitivity test, they will require 75 more pump strokes to complete the fit test.

The automatic Qfit will complete the same sensitivity and fit test in two button pushes (reducing work by more than 95%), and the manual Qfit will do the same in a total of 17 button pushes (reducing work by 80%). If you test hundreds of people per year, this savings adds up quickly!

Don't forget the cartridges!

A limited supply of Bitrex and Saccharin sensitivity and fit test cartridges ship in the Qfit kits. Please order additionals here.

Remember, you will need both sensitivity and fit test cartridges to complete your tests.

Models and Accessories for Sale

Description Catalog No Price

Qfit automatic model, basic kit

Qfit automatic model, deluxe kit

Qfit manual model, basic kit

Qfit manual model, deluxe kit

TSI. Consumable cartridges and some replacement parts are still available.

Accessories Remote handheld nebulizer unit 805015

$OBS

125.00

Bitrex

Cartridges

Saccharin

Cartridges

Sensitivity cartridges

Fit test cartridges, 8-10 tests ea. (80 tests/box)

Sensitivity cartridges

Fit test cartridges, 8-10 tests ea. (80 tests/box)

Qfit replacement hood

Replacement Qfit replacement power supply

Parts Qfit replacement elbow

805009

805010

805012

805013

805005

805007

805008

40.00

80.00

40.00

80.00

30.00

40.00

15.00

Basic kits include Qfit powered nebulizer with rechargeable battery, AC power supply, two elbows with

extension tubes, fit test hood, cartridge holder, Bitrex combo box (8 sensitivity/8 fit test) cartridges, Saccharin combo box (8 sensitivity/8 fit test) cartridges, user manual, quick start guide, and one-year warranty.

Deluxe kits include all basic kit parts plus a remote handheld nebulizer, a hood pouch, blue soft-sided

carrying case, and a Qfit instructional CD.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

529

P

orta

C

ount

® Pro Quantitative Respirator Fit Testers

Features

• Tests people while wearing their own masks to verify proper respirator sizing and fit

• Measures fit factor (>10,000) directly, and shows the effects of mask positioning and strap tightness

• Tests full-face and half-face tight-fitting respirator facepieces, plus NIOSH series 95, 99, and 100 filtering facepieces

• OSHA-compliant for tight-fitting respirators (8030) or for both tight-fitting respirators and disposable masks (8038)

• Stand-alone operation — no external PC required for tests— makes unit quicker to set up and easier to transport and use

• Color touch screen lets you enter user data and administer tests with a the touch of a finger, pen, or stylus

• FitPro™ fit testing software for your PC automates test process, stores results in a database, generates reports, and prints fit test result ID cards to a laser printer

• Prices start under $8,000

Top of the class and still climbing

TSI, the leader in respirator fit testing, just made their best even better. The OSHA-compliant PortaCount® Pro and Pro+ fit testers offer fast, simple, stand-alone operation.

No other respirator fit testers on the market can quantitatively fit test all types of respirators — gas masks, SCBAs, respirators, and

N95 filtering facepiece disposable masks.

Existing qualitative fit test methods, like irritant smoke, banana oil, saccharin and Bitrex® are inherently limited to pass/fail levels and a fit factor of 100. OSHA and NFPA require a protection factor of at least 500 for full-face respirators, and ANSI requires 1000.

There's no qualitative method to meet these requirements.

TSI's PortaCount® family eliminates the guesswork associated with tedious and error-prone qualitative fit test methods.

PortaCount fit testers measure fit while the user performs a series of moving, breathing, and talking exercises, designed to simulate the same movements users will make in the field.

Learn more about the PortaCount® Pro at www.raeco.com/get/8030.php

Two versions

PortaCount Pro 8030 is great for industrial applications that test traditional tight-fitting full-face or half-face masks, or dust masks with N99 or N100 filtering efficiency.

PortaCount Pro+ 8038 tests both industrial and N95 disposable masks. Unlike the older PortaCount Plus models, you don't need an

N95-Companion unit to switch from testing tight-fitting masks to filtering facepieces.

Working with or without a PC

Unlike the older versions of the PortaCount (8020, 8028, and

8095 models), you don't need a PC to perform fit tests. Test data is stored on a formatted USB flash drive, and can be transferred to a

PC for report generation and ID card printing when you need it.

Both the PortaCount Pro and Pro+ have color touch screens that let you control the test with the touch of a finger, pen, or stylus.

The touch screens also provide input for information on each person and the respirators being tested.

If you prefer to work with your PortaCount Pro unit connected to a PC, the new FitPro™ fit test software steps you through the same procedures, and it stores results in a database for easy report generation, retrieval, and regulatory compliance.

See next page for sales and rental pricing.

Immediate, accurate results for fit testing SCBA respirators and disposable masks.

530

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

P

orta

C

ount

® Pro Series Respirator Fit Testers

See next page for respirator mask adapter kits, particle generator, HEPA filters, tubing, and fit test ID card printer and supplies.

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

TSI P

orTa

C

ounT

® Pro and Pro+ Respirator Fit Testers

PortaCount Pro 8030

• For disposable filtering-facepieces Series 100, 99, P3, and HEPA masks

• Half and full-face masks, gas masks, PAPR, and SCBA mask fit testing

• Stand-alone operation for quick setup and use; Connect to a PC to automate, using FitPro™ fit test software, and to print ID cards

• Computes fit factor using microscopic particles in ambient air

TSI 8030 ships with base unit, AC adapter, alcohol cartridge, alcohol fill capsule, storage cap, two zero

check filters, 8016 alcohol supplies, 3/16" and 1/4" hose adapters, two spare alcohol wicks, carrying case, FitPro software CD, 1GB flash memory drive, USB cable, user manual, and two-year warranty.

Rent by the day, week, or month.

See page 586.

PortaCount Pro+ 8038

• Fit test ANY tight-fitting respirator, plus N95, P2, and P1 disposables;

OSHA-compliant for all respirators

• Switches between different respirator types in less than a minute

• Built-in N95 Companion™ technology

• Faster N95 testing — reduced from 10:24 minutes to 7:15 minutes

• Combines functions of retired 8020 and 8095 models

TSI 8038 ships with base unit, AC adapter, alcohol cartridge, alcohol fill capsule, storage cap, two zero check

filters, 8016 alcohol supplies, 3/16" and 1/4" hose adapters, two spare alcohol wicks, 100 sampling probes

(rental ships with 25), probe insertion tool, neck strap, carrying case, FitPro software CD, 1GB flash memory drive, USB cable, user manual, and two-year warranty.

Models and Accessories for Sale

Description

PortaCount Pro respirator fit tester for SCBA and PAPR

Three-year contract for TSI factory annual calibration of 8030

PortaCount Pro+ respirator fit tester for SCBA, PAPR, and N95

Three-year contract for TSI factory annual calibration of 8038

Catalog No Price

8030 $9005.00

CLC3-8030 1835.00

8038 12810.00

CLC3-8038 2630.00

Due to contract restrictions,

TSI PortaCount® instruments are only available for sale within our Midwest regional territory (though parts are available for unrestricted sale). They can be rented anywhere within the US.

TSI MITA 8120 Mask Integrity Test Accessory

• Works with TSI PortaCount Pros to quickly detect leaks in CBRN gas masks and commercial respirators

• Separate tests for overall mask integrity (Protection Factor), exhalation valve, and drink tube

• Single head form with enhanced bladder seal system creates a tight seal for full face respirator types and sizes

• Easy-to-read display with an intuitive step-by-step test sequence — minimal operator training required

• Capable of more than 12 mask assessments per hour

Description

Mask Integrity Test Accessory (MITA)

Mask

Adapter

Kits

Refills

For M40, FR-M40, M45, MCU2P, and Millennium

For M50, and C50

For M53, and FM12

For C4

For MSA Ultra Elite (with 40mm Threaded, Slide or Push-

to-Connect CBRN versions); MSA Advantage 3000

For 3M 6000/7000 Series; 3M7800s/7800B CBRN

For Scott AV2000/AV3000

For Draeger Panorama Nova; and MSA Ultra Twin

Emery Oil, 500 ml Bottle

Catalog No

8120

8125-01

8125-02

8125-03

8125-04

8125-05

8125-06

8125-07

8125-08

801776

Price

$14200.00

605.00

970.00

480.00

485.00

230.00

490.00

450.00

180.00

70.00

Ships with headform, headform mask sample

plug, #1 and #3 rubber stoppers, mask bypass hose, twin tube with 1" relief cut, aerosol wand, aerosol generator assembly, aerosol containment hood, aerosol mixer, mask filter plug, two HEPA filter canisters, drink tube sampling hose, DT and EV bypass hose, 500 mL Emery oil, PortaCount interface cable

(for 8030/8038), MITA computer cable, USB to serial adapter, MITA Communicator software CD, universal

AC adapter with line cord, quick start guide, self-check components reference card, user manual, calibration certificate, and one-year warranty.

Order mask adapter kits separately, as needed.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

531

Respirator Adapter Kits and Accessories

Respirator adapter kits are required for use with TSI P orta

C ount

® Plus 8020 and 8095 and

P orta

C ount

® Pro 8030 and Pro+ 8038 Units

Note: Mask adapter kits are not included with the P

orta

C ount

. If the adapter does not come with your respirator mask, or is not readily available from the respirator manufacturer, see below for a compatible unit. Unless otherwise noted, each kit includes an adapter, P100 HEPA filters, and disposable components for 200 fit tests. See refill kits for additional test supplies.

Adapters and Fit Test Consumables

Adapter to Fit...

3M masks, Including those with detachable filters

Avon masks with drink tube (Also fits US M50)

Dräger Combitox Nova RD91, Cirrus RD91

Dräger masks with standard 40mm filter threads or snap-in connectors

Interspiro Spiromatic and Spirolite SCBA facepiece

Interspiro Spiromatic S and S4 SCBA facepiece

MSA Advantage 1000, Millennium; Also fits 3M FR-M40, US Military MCU-2/P, M40

MSA Millennium, US Military M40/MCU-2P) Adapter Only

MSA Advantage respirators with bayonet filters

MSA Comfo and Advantage half or full-face masks

MSA Ultra Elite, Advantage 3100 (40mm screw-ins)

MSA Ultra Elite with Quarter-Turn MMR (Not for Firehawk)

MSA UltraView (Including SCBA with screw-in connection, Ultra Twin, Phalanx)

MSA UltraView with Quarter-Turn MMR

North masks (5400, 5500, 7600-7800, 80004, 800045, 85400A, 85500A, 800 series)

Protector/Sabre Phantom PAPR with 48mm thread

Scott full-face AV-2000, AV-3000, Scott-O-Vista, 65

Survivair air purifying masks (Includes 2000, Blue 1, Low Maintenance, 4000, 20/20)

Survivair positive-pressure SCBA masks, Panther-style MMR (Classic, 20/20, OPTI-Fit)

US Safety, all masks

Wilson F-series facepieces with 1" screw-on filters

Wilson T-series bayonet-type masks, GT-series small diameter screw-on connections

Generic 40mm facepieces

Gas masks with standard US military drink tubes

Accessories and Consumables

Filtering Facepieces Probe Kit (500 probes and tool set)

Refill Kit for 8025-N95 (500 probes and push-nuts)

Consumables Refill Kit #1 (200 tests: Includes 50' tubing, 200 clips, 200 suction cups)

Consumables Refill Kit #2 (200 tests: Includes 50' tubing, 200 clips, 200 suction cups)

Consumables Refill Kit #3 (200 tests: Includes 50' tubing, 200 clips, 200 suction cups)

Particle generator for PortaCount Pro and Pro+ (Included with PortaCount Plus models)

Salt Tablets for Particle Generator (Bag of 100)

Reagent-grade alcohol (Case of 16 30ml bottles)

Zero check HEPA filter for PortaCount Plus and N95-Companion

Zero check HEPA filter for PortaCount Pro and Pro+

10-Pack alcohol wicks with screens for PortaCount Plus 8020 and 8028

10-Pack alcohol wicks with screens for PortaCount Pro 8030 and Pro+ 8038

Sampling hose kit, three 5' twin tubes, 10 adapters each, 3/16" and 1/4"

Twin tube, one 5' blue/clear tube

18" Pendant twin tubes for N95 testing, pack of five

Compatible

Refill Kit

800553

801633

800553

800785

800785

800785

800553

800553

800553

800553

800553

800553

801633

Catalog

Number

8025-16

Price

$310.00

8025-AVON 155.00

8025-24

8025-26

8025-21

8025-21S

220.00

495.00

665.00

730.00

8025-29

1081379

8025-30

8025-14

8025-22

8025-22Q

8025-15

8025-15Q

135.00

55.00

165.00

360.00

320.00

360.00

220.00

260.00

8025-17

8025-28

285.00

215.00

8025-20

8025-12

8025-13

8025-25

205.00

225.00

435.00

200.00

8025-23

8025-19

385.00

270.00

8025-CEN

220.00

8025-USMIL

200.00

8025-N95

8025-N95R

800553

800785

801633

8026

803011

8016

1602066

803X-ZFLTR

8023

8033

8017

800197

801501

190.00

130.00

120.00

120.00

135.00

840.00

40.00

115.00

30.00

35.00

135.00

125.00

115.00

25.00

45.00

532

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Direct-Read Passive Monitoring Badges

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

ChromAir and SafeAir Direct-Read Passive Monitoring Badges

For exposure limits

Don't see the badge you need?

Visit www.Raeco.com

or call 800-852-9795.

Model Selection Guides — ChromAir

Analyte

Acetone

Methyl Ethyl Ketone

Methyl Isobutyl Ketone

Ammonia

Carbon Monoxide

Chlorine

Formaldehyde

Glutaraldehyde

Hydrogen Sulfide

Mercury

mg/m 3 •hr

Ozone

Min. Detectable

Range Concentration

(ppm•hr) (ppm) 8 Hours

20 - 24000

18 - 21600

16 - 19200

2.50

2.25

2.0

4 - 300

10 - 525

0.4 - 13

0.3 - 12

0.50

1.25

0.05

0.04

Interferences

Catalog

Number

(10/Box) Price

NH

3

, MEK, MIBK, MPK

NH

3

, Acetone, MIBK, MPK 380020-10 $124.00

NH

3

, MEK, Acetone, MPK

RNH

2

Alkenes, H

2

, H

2

S

380003-10 124.00

380008-10 124.00

Br

2

, I

2

, HCl

Acrolein

380004-10 124.00

380007-10 124.00

STEL (15 min)

1 - 240

0.125 - 1.6

0.08 - 1.6

0.04 - 0.95

0.13

0.02 mg/m 3

0.01

None Known

None Known

Strong Oxidizers

H

2

O

2

, NO

2

380017-10

380009-10

380018-10

128.25

124.00

128.25

380010-10 124.00

All ChromAir badges ship direct from the factory via air service.

For presence of chemical hazards

Don't forget to order your reusable clips!

#401966-10

$6.50 per 10-pack

Model Selection Guides — SafeAir

*Maximum/Shortest Recommended Sampling Times.

Analyte

Aromatic Isocyan-

ates (MDI/TDI)

Min. Detectable

Threshold Concentration MRST* SRST*

Level (ppm) 8 Hours (Hrs) (Mins)

TDI: 5.0 ppb•hr

MDI: 3.5 ppb•hr

TDI: 0.6 ppb

MDI: 0.4 ppb 24

Cross-

Sensitivity

Catalog

Number

(50/Box) Price

Aromatic Iso-

15 cyanates, Hydrazine 382001-50 $189.50

Carbon Monoxide

Chlorine

Chlorine/

Chlorine Dioxide

7 ppm•hr

0.18 ppm•hr

Formaldehyde

Hydrazine

0.4 ppm•hr

8.0 ppb•hr

Hydrogen Chloride 2.0 ppm STEL

1 ppm

0.025 ppm

CI

2

: 0.18 ppm•hr CI

2

: 0.025 ppm

CIO

2

: 0.2 ppm•hr CIO

2

: 0.025 ppm

0.05 ppm

1.0 ppb

Ozone

Phosgene

Sulfur Dioxide

0.05 ppm•hr

0.015 ppm•hr

0.2 ppm•hr

0.006 ppm

0.002 ppm

0.025 ppm

48

72

48

10

48

10

15

15

15

Alkenes, H

2

, H

2

S 382012-50 155.00

Br

2

, HCI, I

2

382009-50 155.00

CI

2

: Br 2 , HCI, I

2

382003-50 189.50

CIO

2

: NO

2

, High

Concentration O

3

Acrolein 382011-50 155.00

16 15

48 15 MMH, Aromatic 382002-50 189.50

Amines

None Known 382024-50 189.50

15

1

15

H

2

O

2

, above 382004-50 155.00

1 ppm NO

2

COBr

2

, CNCl, ClCO

2

382000-50 155.00

None Known 382014-50 155.00

All SafeAir badges ship direct from the factory via air service.

Color Comparators

For higher resolution and wider range, use your ChromAir or SafeAir badge with a color comparator.

ChromAir Color

Comparators

Range Catalog

(ppm•hr)* Number Price

Carbon Monoxide

Chlorine

Formaldehyde

4 – 630

0.2 – 20.0 384005

0.3 – 40.0

0.12 – 3.2

384006 $54.00

384001

Hydrogen Sulfide 0.4 – 350.0 384002

Mercury 384003

54.00

54.00

54.00

54.00

* Range mg/m 3 •hr

Catalog

SafeAir Color Comparators Number Price

Chlorine

Chloroformates

Hydrogen Chloride

Hydrazine

Phosgene

Phosgene Extended Range

Toluene Diisocyanate (TDI)

383010 $48.50

383002 48.50

383008

383007

383005

48.50

383001 38.75

383000 38.75

48.50

48.50

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

533

Gas Detection in a Single Stroke

Sensidyne AP-20S Gas Detection Pump Kit

• Single stroke operation for ease of use

• Ergonomically designed, sure-grip, lightweight and corrosion resistant

• Failsafe handle locks in two positions, eliminating incomplete samples

• No lab turnaround time, no power or calibration needed

• Indicates flow finish and concentration level of measured gas or vapor

Kit includes Pump, carrying bag, three spare tube holders, lubricant, and manual. Detector tubes sold separately. See below for common gases. Visit Raeco.com to buy others.

Rent by the day, week, or month.

See page 582.

Models and Accessories for Sale

Description

AP-20S gas detection pump kit

Grease

Rubber Tube Holder (Inlet Flange) Pack of 2

Canvas Pump Kit Carrying Bag

Accessories Hot Probe

Hot Probe Holder for AP-20S Pump

Deluxe Tube Tip Cutter

Telescoping Extension Probe (9.84'/3m)

Extension Hose (16.4'/5m)

Extension Hose (32.8'/10m)

Catalog No Price

830-0001-01 $407.00

41580020 19.00

830-1005-01

7013586

10.00

37.00

7013602 195.00

830-1013-01 145.00

7013601 54.00

830-1003-01 902.00

830-1001-01 163.00

830-1002-01 213.00

Detector Tubes Model Selection Guide (Boxes of 10 Tubes for $69.00 per Box)

Gas/Vapor

Acetic Acid

Acetone

Range

1–50 ppm

20–5000 ppm

Acrolein

Acrylonitrile

Ammonia

Benzene

0.005–1.8 %v

0.25–20 ppm

0.1–1.0 %v

0.5–10.0 %v

0.5–30 %v

0.2–20 ppm

1–200 ppm

5–260 ppm

50–900 ppm

0.1–75 ppm

0.2–80 ppm

1–100 ppm

Benzene in Hydrocarbons 5–300 ppm

Butadiene

Carbon Dioxide

30–600 ppm

0.1–2.6 %v

1.0–20.0 %v

5–50 %v

100–4000 ppm

Carbon Disulfide

Carbon Monoxide

0.8–50 ppm

30–500 ppm

0.1–2.0 %v

0.1–20 %v

1–50 ppm

10–250 ppm

30–500 ppm

5–2000 ppm

0.5–60 ppm Carbon Tetrachloride

Carbonyl Sulfide

Chlorine

Dichloromethane

Diethyl/Trimethyl Amine

Dimethyl/Ethyl/

Methyl Amine

5–60 ppm

0.05–2 ppm

0.1–10 ppm

1–40 ppm

10–1000 ppm

1–20 ppm

1–20 ppm

Ethyl/Butyl/Isobutyl Acrylate 5–60 ppm

Ethyl & Methyl Cellosolve 5–500 ppm

Ethyl Alcohol 0.05–5.0 %v

168SB

126SA

126SH

126UH

126SF

141SB

141SA

106SH

106UH

106SC

106S

106SS

106SA

147S

239S

109U

109SB

109SA

180S

222S

Catalog

Number

216S

102SD

136

128SD

105SM

105SA

105SH

105SD

105SE

105SC

105SB

118SD

118SE

118SC

118SB

227S

211U

190U

104SA

Gas/Vapor

Ethyl Benzene

Ethyl Mercaptan

Ethyl Mercaptan (LP Gas)

Ethylene

Ethylene Glycol

Formaldehyde

Gasoline

General Hydrocarbons

Hydrogen

Hydrogen Chloride

Hydrogen Cyanide

Hydrogen Fluoride

Hydrogen Peroxide

Hydrogen Sulfide

Hydrogen Sulfide in SO2

Hydrogen Sulfide &

Mercaptans

Isobutyl Acetate

Isopropyl & Ethyl Acetate

Isopropyl Alcohol

Mercaptans

Methyl Alcohol

Methyl Bromide

Methyl Ethyl Ketone

Methyl Mercaptan

Range

10–500 ppm

1–160 ppm

2.5–80 ppm

20–1200 ppm

20–250 mg/M3

0.05–4 ppm

1–35 ppm

0.05–0.6 %v

50–1400 ppm

0.05–0.8 %v

0.4–40 ppm

20–1200 ppm

0.3–8 ppm

0.5–100 ppm

0.25–30 ppm

0.5–10 ppm

0.25–4 gr/100CF

0.1–4.0 %v

0.2–6.0 ppm

0.5–40 ppm

1–60 ppm

0.75–300 ppm

25–2000 ppm

0.005–0.16 %v

1–30 ppm

10–400 ppm

10–1000 ppm

20–1200 ppm

0.5–10 ppm

0.05–6.0 %v

20–1000 ppm

0.5–10 ppm

0.4–80 ppm

10–500 ppm

20–1500 ppm

5–140 ppm

50–1000 ppm

153U

111U

150U

130U

119SA

119U

157SC

157SB

157SA

139U

164SA

164SH

Catalog

Number

179S

165SA

165SB

108SA

232SA

171SC

171SB

110S

187S

137U

173SB

173SA

112SC

112SB

156S

247S

120GT

120SH

120U

120SE

120SD

120SB

120SF

120SC

282S

Gas/Vapor

Methyl Styrene

Range

10–500 ppm

N,N-Dimethyl Formamide 1–30 ppm n-Hexane

Nitric Acid Vapor

Nitric Oxide & NO2

Nitrogen Dioxide

Nitrogen Oxides

Organic gases

Oxygen

Ozone

Phenol & Cresol

Propyl Acetate

5–800 ppm

50–1400 ppm

1–20 ppm

NO: 10–300 ppm,

NO2: 1–40 ppm

0.1–1.0 ppm

0.5–30 ppm

20–1000 ppm

0.5–30 ppm

20–250 ppm

100–2500 ppm

Qualitative

1.5–24 %v

0.025–3.0 ppm

2.5–100 ppm

0.5–25 ppm

20–1000 ppm

Styrene

Sulfide Ion **

Sulfur Dioxide

Sulfuric Acid

Tetrachloroethylene

Toluene

Trichloroethylene

Water Vapor

Water Vapor **

Xylene

Catalog

Number

193S

196S

113SC

113SB

233S

174A

1–100 ppm

2.5–300 ppm

0.5–10 ppm

2–1000 ppm

0.25–10 ppm

1–60 ppm

20–300 ppm

0.5–5 mg/M3

0.2–10 ppm

2–100 ppm

10–500 ppm

100–3000 ppm

0.2–16 ppm

5–300 ppm

0.05–2.0 mg/l

1.7–33.8 mg/l

2–12 lb/MMCF

3–80 lb/MMCF

5–200 ppm

177UR

177UL

143SB

** Box Price: $67.00

158SB

158S

200SB

200SA

103SE

103SD

103SC

244U

135SB

124SB

124SA

124SH

134SB

134SA

177U

177SA

117SD

117SB

117SA

175U

175SA

175SH

186B

159SC

182U

182SB

183U

151U

534

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Single Gas, Leak, and Airborne Contaminant Detectors

Formaldemeter htV Airborne Formaldehyde Meter

• Electrochemical formaldehyde sensor and built-in sampling pumps

• Rapid response time (< 10 seconds)

• Display shows real-time formaldehyde levels, temperature, humidity

• Sampling frequency typically once every three to five minutes, depending on previous readings; Automatically stores last 10 readings

• Simple in-field calibration

• Continuous monitoring via stand-alone AMS-2 base station or SPC-2 controller module (connecting Formaldemeter unit directly to PC)

Rent by the day, week, or month.

See page 583.

Models and Accessories for Sale

Description

Formaldemeter htV kit (0.05–10 ppm detection range)

Catalog No Price

02700-100 $2295.00

AMS-2 datalogging base station, download software, cable 02700-253 3195.00

SPC-2 single point controller for continuous monitoring via PC 02700-262 2195.00

Phenol filters, replacement 10-pack 02700-002 50.00

Formaldehyde sensor replacement (3-4 year typical life) 02700-003 510.00

Formaldemeter htV kit includes the meter, 10 phenol filters, thermometer, pen, 9V Alkaline battery, calibra-

tion standard, instruction manual, and case. SPC-2 kit communication transfer module with power supply,

htV connector cable, serial port and USB cables and connectors, plus download software.

GasCheck Intrinsically Safe Handheld Gas Leak Detector

• For search and location of non-flammable gases — ideal for Helium detection; Calibrated against Helium, R134a and other gases

• Micro thermal conductivity detector (TCD)

• 5000is logs up to 36,000 data points with time/date stamp

• Flashing LED and 90 dBA audible alarms

• Peak Hold function shows maximum leak rate

Rent by the day, week, or month.

See page 583.

Models and Accessories for Sale

Description

3000is intrinsically safe gas leak detector

5000is intrinsically safe datalogging gas leak detector

IR Link for GasCheck 5000is, infrared adapter and software

Catalog No Price

GC3SABXS-X $4722.00

GC5SABXS-X 5916.00

A-28170M 1125.00

Comes with Four AA Alkaline

batteries, 10" probe, nozzle replacement tool, spare battery clip, operation manual, and ABS plastic carrying case.

MVI Portable Real-Time Mercury Vapor Monitor

• Dual beam UV absorption technology — no saturation, no regeneration — eliminates instrument downtime

• Range 0.1 to 200 and 1.0 to 1999 microgram/cubic meter

• High performance pump delivers fast indication and recovery

• Real time response within 3 seconds

• Audible alarm and digital display standard

Models and Accessories for Sale

Description

Portable mercury vapor indicator with case

Data logger assembly

PTFE water trap filter, 1.0 micron

Probe and 10-pack water trap filters

Carbon filter assembly

Catalog No Price

MVSSRXME-X $9600.00

A-869204

4/JLF-03

A-26007

A-31057

625.00

10.00

100.00

51.00

Rent by the day, week, or month.

See page 583.

MVI includes device and bat-

tery charger, stainless steel probe, zeroing charcoal filter, internal dust filter, and certificate of calibration.

Order other accessories separately.

RAECO LIC-LLC www.RAECO.com [email protected]

Download readings to your PC with the IR

DataLink USB adapter.

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

535

Single Gas Detectors with Adjustable Alarms

GasAlert Extreme Single Gas Monitors

• Direct real-time gas concentrations on large LCD display

• Compact and lightweight (2.9 oz), so it's comfortable to wear

• Visual, vibrating, and 95 dB audible alarms for high, low, STEL and TWA

• Secure and accurate history with datalogging; Uses compatible infrared to USB DataLink adapter to take readings from unit to PC

• Fully functional self-test at every startup for sensor integrity, battery status, circuit integrity, and audible/visual alarms

• Compatible with MicroDock II calibration and bump test station, plus hand aspirator or Sampler motorized pump kit

• Two-year battery life — for use through consecutive work shifts

• UL-approved Class I, Div 1, Groups A–D and Class II, Div 1, Groups E–G

Models and Accessories for Sale

Description

GasAlert Extreme single gas monitor

Ammonia (NH3) 0-400 ppm

Gas and Carbon monoxide (CO) 0-1000 ppm

Range H2-resistant carbon monoxide (CO) 0-1000 ppm

Chlorine (Cl2) 0-50.0 ppm

Hydrogen sulfide (H2S) 0-100 ppm

Oxygen (O2) 0-30%

IR DataLink USB adapter (Required for data downloads)

3V spare Lithium battery

Replacement Sensors

Ammonia (NH3) sensor, 0-400 ppm

Carbon monoxide (CO) sensor, 0-1000 ppm

H2-resistant carbon monoxide (CO) sensor, 0-1000 ppm

Chlorine (Cl2) sensor, 0-50.0 ppm

Hydrogen sulfide (H2S) sensor, 0-100 ppm

Oxygen (O2) sensor, 0-30%

Catalog No

GAXT-A2-DL $510.00

GAXT-M-DL 275.00

GAXT-M2-DL 410.00

GAXT-C-DL

GAXT-H-DL

410.00

275.00

GAXT-X-DL-2 275.00

GA-USB2

E2829

230.00

15.00

SR-A204

SR-M04-SC

PS-RM04H

PS-RC10

PS-RH04S

SR-X10-C1

Price

350.00

225.00

300.00

350.00

225.00

165.00

Rent by the day, week, or month.

See page 582.

Don't see the gas or range you need? Call us!

Kit includes detector in concus-

sion-proof housing, selected sensor, field replaceable battery, stainless steel alligator clip, calibration/test cap and hose, user manual and quick reference card.

MicroDock II Automatic Test and Calibration Station

• Stand-alone or networkable, fully automatic hands-free calibration and functional bump testing

• Verifies performance of audible and visual alarms

• Stores and updates calibration records, including time and date stamps for last calibration and last bump test

• Add extra docking modules for working with multiple gas detectors

Ethernet-capable, just add Network

USB adapter!

Models and Accessories for Sale

Description

MicroDock II calibration and bump test base station

Demand flow regulator (required)

Network USB to Ethernet communication adapter

Wall mount adapter kit for base station, docking modules

Catalog No

DOCK2-2-00-G

REG-DF-1

DOCK2-LAN-1P

WMA-DOCK

Price

$995.00

360.00

435.00

25.00

GasAlert Docking module, charging, power supply

Quattro Docking module, non-charging

GasAlert Docking module, charging, power supply

Micro5 Docking module, non-charging

DOCK2-0-1CN-00-G

DOCK2-0-1N-00-G

550.00

500.00

DOCK2-0-1C1K-00-G 700.00

DOCK2-0-1J-00-G* 550.00

GasAlert Max XT docking module, charging, power supply DOCK2-0-1C1M-00-G 550.00

GasAlert Extreme docking module, non-charging DOCK2-0-1D-00-G 500.00

* Not for use with ClO2 or O3.

Includes base station,

docking modules (one per detector as needed), charging cable as ordered, AC line power adapter, memory card, BW

Fleet Manager II data analysis software, USB connector cable, fresh air inlet filter, four C

Alkaline batteries, 2' calibration gas hoses, one gas cylinder inlet fitting, and user manual.

Order detectors separately. Call for calibration gas pricing.

536

RAECO LIC-LLC www.RAECO.com [email protected]

Portable Multigas Detectors

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

GasAlert Max XT II Personal Multigas Detector

• Continuous monitoring of CO, O2, H2S, and %LEL concentrations

• Integral sampling pump, built-in datalogging feature

• Visual, vibrating and 95 dB audible alarms for high, low, STEL, TWA, over limit, low battery, and pump

• Full function self-test of sensor and circuit integrity, battery status, and audible/visual alarms at startup; Continuous sensor and battery testing; Compatible with MicroDock II for calibration and bump tests

Basic unit includes detector, specified sensors, stainless steel alligator clip, concussion-proof housing,

rechargeable lithium polymer battery and charging adapter, calibration hose, sampling hose with particulate filter, reversible screwdriver, five spare pump filters, printed manual plus CD-ROM.

Models and Accessories for Sale

Description Catalog No Price

GasAlert Max XT II datalogging 4-gas detector with pump XT-XWHM-Y-NA $880.00

GasAlert Max XT II confined space kit XT-CK-DL 475.00

Auxiliary filter kit, 5-pack

Hydrophobic pump filter kit, 5-pack

Accessories Particulate pump filter kit, 5-pack

Quad sensor screen filters, 2-pack

Replacement rechargeable battery pack

MICROceL O2 sensor

Replacement MICROceL H2S sensor

Sensors MICROceL CO sensor

MICROpeL LEL sensor

M5-AF-K2

XT-RF-H5

GA-PFMAX

XT-SS-1

XT-BAT-K1

SR-X2V

SR-H-MC

SR-M-MC

SR-W-MP75C

35.00

15.00

15.00

20.00

50.00

165.00

120.00

120.00

120.00

Confined space kit includes

IR connectivity kit, 0.5 LPM regulator, 10' and 3' hoses, sampling probe, concussion-proof boot, auxiliary filter, FleetManager II software CD, and carrying case with foam insert. Order detector separately. Call for calibration gas options.

Next generation

GasAlert Micro and

MiniMax X4

Patented SureCell™ toxic sensors and

Reflex™ sensor fault diagnostics technology.

GasAlert Quattro Personal Multigas Detector

• Continuous monitoring of CO, O2, H2S, and %LEL concentrations

• Full function self-test of sensor and circuit integrity, battery status, and audible/visual alarms at startup; Continuous sensor and battery testing; Compatible with MicroDock II for calibration and bump tests

• Multiple alarms: Six red LEDs, vibrating, 95 dB audible for high, low,

STEL, TWA and over limit

• Enhanced resistance to common industrial cross-sensitive gases, like methanol and ethanol

Rent by the day, week, or month.

See page 582.

Includes detector, sensors, rechargeable battery pack, wall charger, calibration cap and tubing, reversible

screwdriver, concussion-proof housing, stainless steel alligator clip, user manual, materials booklet and technical reference guide.

Models and Accessories for Sale

Description

GasAlert Quattro, rechargeable, for %LEL, O2, H2S, CO

IR connectivity kit with Fleet Manager II software

SamplerPak motorized sampling pack kit

Spare rechargeable battery pack

Accessories Replacement power adapter

Five-unit power adapter

Five-unit cradle charger

Quad sensor screens, 2-pack

Quad sensor screens, 10-pack

SureCell Combustible sensor (0-100% LEL)

Replacement Oxygen sensor (0-30.0% O2)

Sensors Carbon monoxide sensor (0-1000 ppm CO)

Hydrogen sulfide sensor (0-200 ppm H2S)

Replacement screw kit (40 screws)

Catalog No Price

QT-XWHM-R-Y-NA $755.00

GA-USB1-IR 80.00

GA-SPAK

QT-BAT-R01

OBS

95.00

GA-PA-1-NA 15.00

GA-PA-1-MC5-NA 100.00

QT-C01-MC5 250.00

QT-SS

QT-SS-K1

SR-W04-75C

SR-X10-C1

SR-M04-SC

SR-H04-SC

QT-SCREW-K1

15.00

75.00

170.00

165.00

225.00

140.00

10.00

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

537

GasAlert Micro5 Portable Five-Gas Monitor with PID

• Simultaneously displays measured concentrations of oxygen, combustibles, and toxic gases

• Available with electrochemical cells, catalytic bead sensors, PID for volatile organic compounds, and NDIR for CO2 monitoring

• Pre-calibrated sensor cartridges detect H2S, CO, O2, SO2, PH3, NH3,

NO2, HCN, Cl2, ClO2, combustibles (0–100% LEL or 0–5.0% volume methane), VOCs (PID), CO2 (IR); Patented SureCell™ toxic sensors

• Built-in correction factors for LEL and PID

• Four alarm levels: Low, high, TWA, and STEL; Internal 95 dB audible alarm, internal vibrating alarm for high noise areas, and four bright wide-angled alarm bars

• Rugged, impact-resistant housing, waterproof to IP67

• Full function self-test of sensor and circuit integrity, battery status, and audible/visual alarms on startup; Compatible with MicroDock II calibration and bump test systems (not for ClO2 or O3)

• Datalogging stores several months of continuous data

Rent by the day, week, or month.

See page 582.

Common Sensor Ranges

Sensor

CO

O2

H2S

Range

0–500 ppm

0–30.0%

0–500 ppm

Resolution

1.0 ppm

0.1%

1.0 ppm

%LEL 0–100% LEL (0–5.0% v/v) 1% (0.1%)

CO2 0–50,000 ppm (0–5.0% v/v) 50 ppm (0.01%)

NH3

SO2

VOCs

0-100 ppm

0–150 ppm

0–1000 ppm

1.0 ppm

1.0 ppm

1 ppm

Model

5, 5IR, 5PID

5, 5IR, 5PID

5, 5IR, 5PID

5, 5IR, 5PID

5IR

5

5

5PID

Models and Accessories for Sale

Description Catalog No Price

GasAlert Micro5 datalogging detector, yellow case, rechargeable lithium polymer battery

Gases %LEL, O2, H2S, CO, SO2

CO2 (IR), %LEL, O2, H2S, CO

M5-XWSY-R-D-D-Y-N-00

M5IR-XWBY-R-D-D-Y-N-00

$1450.00

1980.00

Pump version GasAlert Micro5 datalogging detector, yellow case, with rechargeable lithium polymer battery

Gases

%LEL, O2, H2S, CO, SO2

VOCs, %LEL, O2, H2S, CO

CO2 (IR), %LEL, O2, H2S, CO

H2S sensor

CO sensor

Replacement SO2 sensor

Sensors TwinTox (CO and H2S) sensor

O2 sensor

%LEL combustible sensor, filter

CO2 (IR) sensor

VOC PID sensor, 10.6 eV

M5-XWSY-R-P-D-Y-N-00

PS-RH04S

SR-M04-SC

PS-RS04

D4-RHM04

SR-X10-C1

SR-W04

SR-B04

SR-Q07

1575.00

M5PID-XWQY-R-P-D-Y-N-00 1895.00

M5IR-XWBY-R-P-D-Y-N-00 2105.00

225.00

225.00

350.00

350.00

165.00

170.00

1000.00

850.00

Accessories

GasAlert Micro5 confined space kit

10.6 eV PID lamp for VOC sensor

Cleaning kit for PID sensor

Rechargeable battery pack

Quad sensor screen filters, pack of 2

M5-CK-DL

RL-PID10.6

M5PID-CLK-K1

M5-BAT08

M5-SS

350.00

240.00

35.00

150.00

20.00

Detector comes with specified sensors, sensor compartment cover for diffusion operation, calibration

adapter and hose, integral concussion-proof boot, lithium polymer battery pack, slip-in charger cradle with wall adapter, interactive training and technical documentation CD, quick reference guide.

Confined space kit includes carrying holster, sampling probe with hose, calibration hose with quick-

connect fitting, 0.5 LPM regulator, foam-lined carrying case with space for M5 and cal gas. Detector and calibration gas cylinder sold separately.

538

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

PIDs and FIDs for Rapid VOC Detection

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

PhoCheck Tiger Photoionization Detector (PID) for VOCs

• Wide dynamic range ppb to 20,000 ppm for specific volatiles

• Accuracy to ±5% display reading ±1 digit

• LED, vibratory, and audible alarms — pre-programmed time-weighted average

(TWA) and short-term exposure limits (STEL) for 450 different gases

• Logs >120,000 date-time-stamped data points, 33 hours at one log per minute

• Intrinsically safe ATEX, IECEx, and cUL approvals

Rent by the day, week, or month.

See page 583.

Models and Accessories for Sale

Description

PhoCheck Tiger PID with 10.6 eV lamp

PID lamp cleaning kit

Accessories Lithium ion rechargeable battery pack

MiniPID lamp, Krypton, 10.6 eV

MiniPID lamp, Argon, 11.7 eV

Catalog No Price

PTXSLBME-0000 $3895.00

A-31063

A-861240

LA4TM600

LA4SM700

25.00

339.00

146.00

357.00

Includes Detector, PID lamp and

cleaning kit, rechargeable battery, charger and power adapter, rubber boot, explorer case, USB memory stick with software, carbon zero filter assembly, PTFE filter disc, MiniPID stack removal tool, 60mm probe tube, lanyard,

USB cable, and user manual.

PhoCheck Tiger Select Benzene/Total Aromatic Compound Detector

• Fast to detect total aromatic compounds to 20,000 ppm gas-dependent

• Detects benzene in other compounds with selective benzene pre-filter tube (0–40 ppm);

Detects benzene without tubes in areas of benzene gas only

• Accuracy to ±10% display reading ±1 digit

• LED, vibratory, and audible alarms — plus

15-minute STEL and 8-hour TWA

• Logs >120,000 date-time-stamped data points, 33 hours at one log per minute

• Intrinsically safe ATEX, IECEx, and cUL approvals

Models and Accessories for Sale

Description

Tiger Select basic instrument

Tiger Select instrument with datalogging

Catalog No Price

PTXSLBME-0512 $5043.00

PTXSLBME-0516 5822.00

PID lamp cleaning kit

Accessories Lithium ion rechargeable battery pack

MiniPID lamp, Krypton, 10.6 eV

MiniPID lamp, Argon, 11.7 eV

A-31063

A-861240

LA4TM600

LA4SM700

25.00

339.00

146.00

357.00

Includes Detector, PID lamp, battery, battery charger and power adapter, rubber boot, explorer case,

USB memory stick with software, Draeger benzene pre-filter tubes, pellet pack PPB, Draeger Benzene pre-filter tube opener, carbon zero filter assembly, PTFE filter disc, MiniPID stack removal tool, lanyard,

PID lamp cleaning kit, coated sensor seal, Tiger Select calibration connector and calibration adapter, o-ring, electrode stack, USB cable, quick-start guide and user manual.

Need continuous VOC monitoring? Get the

Ion Science TVOC.

Prices start at $2960.00

Cub Personal PID for Volatile Organic and Total Aromatic Compounds

• Measures 480 selectable VOC and TAC compounds, benzene selective

• Detects gases in 1 ppb to 50,000 ppm ranges

• Less than 13 second response to hazardous gases and vapors

• Clear audio, visual, and vibrating alarms

Models and Accessories for Sale

Description

Cub personal photoionization detector, PPM range

Cub personal photoionization detector, PPB range

Cub personal PID, total aromatic compounds

PID lamp cleaning kit

Accessories MiniPID lamp, Krypton, 10.6 eV

Belt clip kit

Catalog No

TCPSXCXX-X

TCBSXCXX-X

TCTSXCXX-X

A-31063

LA4TM600

A-871019

Price

$1363.00

1678.00

1681.00

25.00

146.00

24.00

Includes Detector, docking sta-

tion, remote calibration adapter, accessory kit, stack removal tool, power cable, USB cable, quick start guide, and calibration certificate.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

539

What gases can the FTIR gas analyzer measure?

The Gasmet™ FTIR gas analyzer can measure any gas except the following: Noble (or Inert) gases; Homonuclear diatomic gases (N

2

, Cl

2

, H

2

, F

2

, etc.); H

2

S

Gasmet DX4040 Portable Ambient Air FTIR Gas Analyzer

FTIR analyzer now available from RAECO!

• Real time measurement and display multiple gases to sub-PPM detection limits

• Single-button unknown gas identification in the field using a tablet PC

• Uses a spectral library of >5000 compounds to identify gases and warn for false positives

• Automatically compensates for cross interferences in the analysis

• No sample preparation required, no consumable parts to replace

• No span calibrations required, only periodic zeros using nitrogen or clean air

• Saves all sample spectra for analysis, logs GPS data with gas measurements

• Wireless communication (Bluetooth, WiFi, 3G)

The Gasmet DX4040 portable FTIR gas analyzer detects organic and inorganic gaseous compounds in real time by their absorbance of infrared radiation. Because each molecular structure has a unique combination of atoms, each produces a unique infrared spectrum. From this, it's possible to identify (qualitative analysis) and analyze (quantitative measurement) the compound. An

FTIR analyzer simultaneously measures multiple analytes in a complex gas matrix, detecting virtually all gas-phase species.

Gasmet FTIR gas analyzers offer greatest benefits when you need to analyze several components at once, analyze the gas hot/wet (hot/humid applications for HCN, NH

3

or HCl), or analyze any gas in complicated gas mixtures. The DX4040 is ideal for applications including chemical spill, security, forensic investigation, occupational health, anaesthetic gases, greenhouse gases, refrigerants, leak detection, VOCs, and research.

Models and Accessories for Sale

Description

FTIR portable multigas analyzer

Catalog No Price

DX-4040 $43603.00

Choose a

Gas App

Library

20 user-selectable gases

25 toxic industrial compounds

25 common hospital gas compounds

GAS-LIB-402 0.00

GAS-LIB-404 3163.00

GAS-LIB-405 15171.00

NIST 5000+ gas library (Requires Calcmet Pro) GAS-LIB-409

Calcmet 4040 Pro software and HASP key

Accessories DX-4040 spare lithium ion battery

GAS-SW-405

GAS-OPT-401

3820.00

10928.00

1475.00

Tabletop battery charger/tester

DX4040 pelican transport case

GAS-OPT-402 1534.00

GAS-OPT-405 1380.00

Ships with MCPT detector,

NAUTIZ X7 PDA with Calcmet Lite v2.0 software, Li-ion rechargeable battery, internal sample pump,

20' Tygon sample line, probe with particulate filter, back-carry harness, 25-gas library (presets to

0–2000 ppm CO2, 0–100 ppm

CH4, N2O, and CO, 0–3% v/v H2O.

MicroFID II Advanced Portable Flame Ionization Detector

• Detects from 0.1 to 50000 ppm volatile organic compounds

• 70-hour hydrogen supply, 15-hour battery life

• Audible and visual alarms

• Compatible with handheld PDA for viewing detection data; Built-in

Bluetooth wireless interface

• Intrinsically safe for Class I, Div 1, Groups A-D hazardous areas

Looking for a fixed

FID gas analyzer?

Call RAECO.

Models and Accessories for Sale

Description Catalog No Price

MicroFID II flame ionization detector A1201060 $11495.00

Accessories

Extension probe, bracket, and carrying strap

Hard-side carrying case with foam inserts

MX396033

A1201225

Juniper Archer PDA (Class 1/Div 2 approved) 40080007

FirstFID software (Windows Mobile 6 or newer) SW201100

Fluoropore water/particulate filter, 25-pack

Charcoal filters for zero calibration, 10-pack

Coalescing filters for moisture, 5-pack

Replacement 70L Hydrogen fuel cylinder

MX396015

MX396022

MX396060

61300001

564.08

512.33

2995.00

305.33

113.85

310.50

170.78

1029.83

Ships with Bluetooth communication, 70L hydrogen cylinder,

15-hour rechargeable battery pack, universal battery charger,

25 Fluoropore membrane filters, and user manual.

540

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Portable Combustion Efficiency Analyzers

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Optional probes extend 320's functionality

Testo Residential/Commercial Combustion Analyzers

Testo 310

• For residential furnace, boiler, and water heater applications

• O2, CO (w/ NOx filters standard), CO2

• Draft and pressure

• Flue and ambient temperature

• Combustion efficiency and excess air

• Undiluted CO (CO air-free) and ambient CO

• Easy-to-read backlit display

Add a printer to either model for easy on-site reporting

Testo 320

• For testing and tuning all types of boilers, heater or furnaces

• O2, CO, CO2, ambient/room CO, CO air-free

• CO sensors with NOx filter, 0–4000 ppm range

• Flue draft, pressure (vent or duct or switches)

• Flue and room temperature

• Combustion efficiency and excess air

• Flue gas matrix with four user-defined combustion types

• Oil flow and gas clock BTU calculator

• Datalogs 500 readings plus customer site ID

Models and Accessories for Sale

Description

310 residential analyzer kit (O2, CO)

310 residential analyzer kit with printer

320 residential/commercial analyzer kit (O2, CO)

320 residential/commercial analyzer kit with printer

Particle filters, 10-pack

Standard smoke pump test kit (scale, filter paper, lubricant)

Thermal printer paper, 10-year legibility, 6 rolls

320 series replacement O2 sensor (0-21.0 vol%)

320 series replacement CO sensor (0-4000 ppm)

Catalog No

0563 3100

0563 3110

Price

$695.00

895.00

0563 3220 70 1195.00

0563 3220 71 1460.00

0554 0040

0554 0307

0554 0568

0393 0003

0393 0053

39.00

189.00

30.00

93.00

176.00

310 includes analyzer, probe/

hose, silicon tubing, 5 extra particuplate filters and pressure plugs, AC power supply/USB charger, calibration certificate and carrying case.

320 includes analyzer, probe/

hose, silicon tubing, 10 extra particulate filters, AC power supply/

USB charger, calibration certificate and carrying case.

Printer kits add infrared printer

and six rolls of thermal paper.

Testo 330-2G LL Combustion Analyzer with Graphical Display

• For gas pipe testing, pressure drop , pipe commissioning, and more

• Graphics let you know when combustion parameters are out of range

• Long life sensors for O2, CO, and NO, with automatic over-range protection

• Calculates CO2, efficiency, excess air, CO air free

• Zeroing feature lets you start the analyzer with probe in flue instrument

• Diagnostics and quick leak check at the touch of a button

• On-board memory stores a half-million measurements

• 20 selectable fuels, including ten user-defined fuels

• Differential pressure, differential temperature and gas leak detection (with optional probes)

Rent by the day, week, or month.

See page 584.

Models and Accessories for Sale

Description

330-2G LL Combustion Kit #1 (CO, O2)

330-2G LL Combustion/NOx Kit (CO, O2, NO)

Fast infrared printer

EasyHeat PC software

USB cable (USB-A to mini-B)

Refill thermal printer paper, 6 rolls

Combustion air temperature probe

NO sensor upgrade module (0–3000 ppm)

Replacement O2 LL long life sensor

Replacement CO LL long life sensor

Replacement NO LL long life sensor

Catalog No Price

0563 3372 71 $2690.00

400563 3372 3595.00

0554 0549

0554 3332

0449 0047

0554 0568

0600 9797

0554 2151

0393 0002

0393 0101

0393 0151

370.00

215.00

27.00

30.00

172.00

995.00

265.00

495.00

480.00

Kits include analyzer, sensors, 12" flue gas probe, lithium ion battery, power supply/charger, 10-pack of

particle filters, standard case.

Due to contract restrictions,

Testo instruments are only available for sale within our

Midwest regional territory

(though parts are available for unrestricted sale). They can be rented anywhere within the US.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

541

Testo 340 Portable Combustion Tuning Analyzer

• Four-gas flexibility in a rugged, compact handheld design

• Automatic sensor protection keeps your analyzer working longer

• Flexible plug and play sensors swap in and out easily in the field

• Replaceable interference filters for CO and NO sensors increase accuracy and extend sensor lifetime

• Optional "dilution overall" extends the range of all sensors (50000 ppm CO, 15000 ppm NO, 25000 ppm SO2)

• Standard probes designed for engine or burner/boiler applications plus industrial probes (good to 3200° F) for extreme tuning flexibility

• Easy-to-use interface — Clear backlit display, simple function keys, information buttons to display functions, sensor diagnostics, and more

• Automatic flow controlled sampling pump

• 18 standard fuels plus 10 software-enabled user-defined fuels

• Measures O2, CO, NO, NO2, SO2, temperature, draft, differential and absolute pressure

• Calculates CO2, efficiency, flue gas loss, and flue gas dewpoint

• Low range CO and NO sensors available for critical measurements

• Prints records to Testo infrared printer (10-year thermal paper)

• Huge datalogging capacity: 100 folders, 10 sites per folder, 200 logs per site

• Compatible with Testo easyEmission software for data management, analysis, and report generation

Rent by the day, week, or month.

See page 584.

Models and Accessories for Sale

Description Catalog No Price

340 emission analyzer standard kit (O2, CO) 400563 3341 $3099.00

340 emission analyzer burner tuning kit (O2, CO, NO, printer) 400563 3342 4250.00

340 emission analyzer engine tuning kit (O2, CO, NO) 400563 3343 4675.00

340 O2 upgrade kit (Add at least one upgrade module)

CO upgrade module (0–10000 ppm, H2 compensated)

CO low upgrade module (0–500 ppm, H2 compensated)

NO upgrade module (0–3000 ppm, 1 ppm resolution)

NO low upgrade module (0–300 ppm, 0.1 ppm resolution)

NO2 upgrade module (0–500 ppm, 0.1 ppm resolution)

SO2 upgrade module (0–5000 ppm, 1 ppm resolution)

O2 replacement sensor

CO replacement sensor

CO low replacement sensor

NO2 replacement sensor

13" probe, 5/16" diameter, 7' Teflon-lined hose

28" probe, 5/16" diameter, 7' Teflon-lined hose

10-pack particle filters for engine probe

10-pack particle filters, disk type for standard handle

Replacement lithium ion rechargeable battery

EasyEmission PC software with USB cable

400563 3344 1865.00

0554 2100

0554 2102

1395.00

1395.00

0554 2150

0554 2152

0554 2200

0554 2250

0393 0001

0393 0100

0393 0102

0393 0200

0600 8764

0600 8765

0554 3371

0554 3385

0554 1103

0554 3334

1395.00

1395.00

1395.00

1395.00

205.00

595.00

575.00

575.00

795.00

995.00

62.00

31.00

68.00

399.00

340 standard kit includes analyzer with O2, CO sensor, power supply/charger, 10-pack probe filters, 12"

probe with 7' Teflon hose, transport case, and documentation.

340 burner tuning kit includes analyzer with O2, CO and NO sensors, fast IR printer and six rolls of paper,

power supply/charger, 10-pack probe filters, 12" probe with 7' Teflon hose, transport case, and documentation.

340 engine tuning kit includes analyzer with O2, CO and NO sensors, 2X overall dilution (for all gases),

power supply/charger, 10-pack probe filters, engine probe with inline filter and water trap, filter removal tool, transport case, and documentation.

340 upgrade kit includes analyzer with O2, power supply/charger, 10-pack probe filters, transport case,

and documentation. Add upgrade modules as required for your application.

Due to contract restrictions,

Testo instruments are only available for sale within our

Midwest regional territory

(though parts are available for unrestricted sale). They can be rented anywhere within the US.

542

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

350 Portable Combustion Efficiency Analyzer

Features

• Test up to six gases simultaneously, or swap sensors out for additional parameters (NOlow, COlow, SO2, H2s, Co2, CxHy)

• Innovative dilution systems for the widest testing ranges and greatest sensor protection(CO to 400,000 ppm, SO, NO2, SO2, H2S to five times the sensor range)

• Advanced sample conditioning uses a thermoelectric chiller for moisture dropout and a peristaltic hose pump for controlled water removal

• Proven sample gas path with Teflon-lined hoses

• Continuous temperature compensation for assured accuracy

• Flow rate and sensor temperature monitoring for US EPA CTM-030, 034, and

ASTM D6522 requirements

• User-defined programs with onboard memory to 250,000 values

• Integrated pressure measurement for draft, differential pressure, velocity, and mass emission

• Comprehensive calculations including O2 corrections for NOx, CO, and SO2, mass measurement with pitot and stack dimension output

• User-defined O2 references for US EPA and state reporting

Emissions testing relies on proper hardware, coupled with accurate measurements. It's critical how the sensors are integrated, flow rate is controlled, and exhaust gas is conditioned. The Testo 350 takes care of all these critical items, and provides the high performance and rugged portability you require.

The unit's rugged housing, bump protection, and industrial connectors let it stand up to any field condition. Ready to start? Just click the application icon, and the analyzer automatically begins its setup process. The proper parameters, correct calculations, and real diagnostics are displayed in full HD color. These features, coupled with the intelligent automatic datalogging and testing programs, makes emission testing easier than ever before.

The new flow-controlled pump and gas paths, built with nonreactive materials) sets a new standard in sampling. No need to fumble with valves and flow meters. The 350 automatically corrects for positive and negative pressures. Smart diagnostics provide more information, and explain steps to correct the situation.

350 Control Unit — Small Size, Huge Capacity

• Measurement interface provides access to field configurations, so testing is faster to set up and easier to perform

• Use the control unit for data storage, and download at your convenience

• Use the fresh air button to purge instead of climbing a ladder to pull the probe

• With remote control, increase accuracy by eliminating long sample lines and long response times

• Click the controller unit face down into the analyzer box for protection and added security

• Includes integrated magnets for mounting to steel surfaces

HD Color Display for Viewing Combustion Data

• Real-time color graphics

• Intuitive operation lets you view collected data in a graph or numeric values

• See the measurements at the control panel via a cabled connection, or up to 300 feet away using Bluetooth

350 Analyzer Box — Where Measurement Begins

• Contains the pumps, sample conditioning, electronics, and up to six sensors

• Sensor temperature monitoring and compensation complement each other for increased accuracy

• Thermoelectric (Peltier) chiller conditions the gas as required by regulatory agencies

• Foam rubber bumpers and components mounted in shockresistant material help protect the device from field use

Built for Serviceability

• Separate sensor chamber ensures thermal stability and the highest accuracy. Minimizes temperature drift due to thermal changes from other electronics or ambient conditions, and maximizes measurement

• Easy-access panels allow for quick servicing

• New digital plug-and-play sensor platform provides easy swapping and sensor change-outs. Field replaceable in seconds and no calibration needed, the sensor electronics maintain the calibration and other critical data. Quick change interference filters assure the highest accuracy

• Fresh air and dilution pump draws fresh air in for purging sensors

• Cooling loop enhances thermal control and analyzer efficiencies, and is designed to isolate the electronics and sensors from harsh ambient conditions, so you can test in dirty locations with confidence

• Automatic flow control and high capacity sampling pump gives you more power to maintain constant flow. The pump will maintain flow rate for best sensor response and accuracy

Designed for EPA combustion engine testing

• Pre- and post-catalyst testing of exhaust gases, linking two analyzers for simultaneous testing, and easyEmissions software for data management and reporting makes the 350 ideal for testing to EPA NESHAP 40 CFR sub ZZZZ and NSPS sub JJJJ standards

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

543

Models and Accessories for Sale

■ =Standard Kit Item (No added charge) (Add

and

as Separate line Items)

◆ =No-Cost Option ❍ =Upgrade and Add to Total Price

Description

350 Boiler and Burner Kit

350 Engine Testing Kit

350 Turbine Testing Kit

Component Description

13" Sampling Probe, 7' Hose (932° F Max.)

13" Engine Probe, 7' hose (1832° F Max)

9' Hose Extension (Max Allowable 25')

Maximum Number of Sensors Allowable

O2 (0-25%)

CO (0-10000 ppm)

CO low (0-500 ppm)

CO2 NDIR (0–50%)

H2S (0–300 ppm)

NO (0-3000 ppm)

NO low (0-300 ppm)

NO2 (0-500 ppm)

SO2 (0-5000 ppm)

CxHy (0-4% hydrocarbons)

Dilution system upgrade

6' Data Bus Cable

16' Data Bus Cable

Catalog

Number

400563 3512

400563 3513

400563 3514

Option

Part Number

0600 9766

0600 8764

0554 1202

0393 0000

0554 2104

0554 2102

0554 2400

0554 2350

0554 2150

0554 2152

0554 2200

0554 2250

0554 2300

0554 3555

0449 0075

0449 0076

↓ n

6 n n

❍ n

❍ n

❍ n

❍ n

❍ n n

6

❍ n

❍ n

❍ n n

❍ n

6 n

❍ n

❍ n n

❍ n n

39" Probe (2200° F), 13' Lined Hose

Bluetooth Fast Printer (300' Range)

Infrared Printer

Thermal Paper, 6 Rolls (10-Year Legibility)

Rugged Pelican Case with Foam Insertion

Replacement Sensor Modules

400600 7803

0554 0553

0554 0549

0554 0568

400516 3515

❍ ❍ ❍

695.00

598.00

370.00

30.00

650.00

O2 (0-25%)

CO (0-10000 ppm)

CO low (0-500 ppm)

CO2 (NDIR 0–50% vol%)

H2S (0–300 ppm)

NO (0-3000 ppm)

NO low (0-300 ppm)

NO2 (0-500 ppm)

SO2 (0-5000 ppm)

CxHy (0-4% hydrocarbons)

0393 0000

0393 0104

0393 0102

0393 0400

0393 0350

0393 0150

0393 0152

0393 0200

0393 0250

0393 0300

217.00

575.00

575.00

3242.00

609.00

575.00

575.00

575.00

575.00

596.00

All systems include: Control unit and analyzer box, Bluetooth 2.0 communications, internal memory to

250,000 readings, advanced sensor temperature compensation, multiple temperature measurement (stack, sensor, ambient), sample flow rate monitoring (EPA compliant), auto CO overrange protection, thermoelectric sample conditioner with condensate removal pump, fresh air valve for automatic programs and long-term testing, differential pressure measurement, USB connection, AC power cable, extra particle filters, 6' data bus communications cable, easyEmissions software, standard carrying case, and calibration certificate.

Price

$9995.00

10995.00

11800.00

Price

Adder

498.00

795.00

310.00

217.00

1395.00

1395.00

3323.00

1763.00

1395.00

1395.00

1395.00

1395.00

1560.00

1695.00

130.00

201.00

Rent by the day, week, or month.

See page 584.

Due to contract restrictions,

Testo instruments are only available for sale within our

Midwest regional territory

(though parts are available for unrestricted sale). They can be rented anywhere within the US.

E

aSy

E

mISSIonS

Data Management Software

• Real time analyzer control through your PC, showing tabular, graphical, and picture box results

• User-defined oxygen reference levels

• Calculates maximum, minimum, and mean values

• Logging intervals once per second to once per hour

• Custom formulas for specific report calculations

• Quick data transfer to Microsoft® Excel® or Adobe® PDF

• Included with Testo 350 kit purchases

544

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Heat Stress Monitors

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

QUESTemp Portable Heat Stress Monitors

• Heat stress monitor with integral RH sensor for quick, accurate indoor or outdoor WBGT index values

• Multiparameter sensor for accumulations of temperature, humidity and air velocity data needed to calculate thermal comfort indices

• Protect against exertion heat illness

• Datalogging intervals of 1, 2, 5, 10, 15, 30, or 60 minutes; Time and data stamping with clock and calendar function

• Displays stay times for ACHIG, TLV, US Navy PHEL charts, US Marine

Corps flag system, EPRI action limits

• Ensures safe work time with real-time guidance on work/rest regimens

• Meets ISO requirements for head, torso, and ankle measurements

(with tri-sensor assembly)

NOT intrinsically safe.

Feature

Dry bulb temperature sensor

Wet bulb temperature sensor

Waterless wet bulb (humidity sensor)

Globe temperature sensor

Relative humidity sensor

WBGT indoor index

WBGT outdoor index

Heat index/HUMIDEX

Datalogging, time/date stamping

UL/CSA Intrinsically Safe

Air velocity probe

QT-32 QT-34 QT-36 QT-44 QT-46 QT-48N

• • • • • •

• • •

Opt.

Opt.

Models and Accessories for Sale

Description

QUESTemp 32 with 2" globe sensor

QUESTemp 34 with 2" globe sensor

QUESTemp 36 with 2" globe sensor

Catalog No

QT-32

QT-34

QT-36

Price

$1667.00

2807.00

3075.00

QUESTemp 44, humidity sensor, and 2" globe sensor

QUESTemp 46, humidity sensor, and 2" globe sensor

QUESTemp 48N with replaceable rH sensor, 2" globe sensor

QT-44

QT-46

QT-48N

2925.00

3194.00

3349.00

Air Probe-9 air flow sensor for velocity measurements AIRPROBE-120 1790.00

NiMH battery and 120 VAC charger for QUESTemp monitors QT-NMH-120 219.00

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Rent by the day, week, or month.

See page 579.

Due to contract restrictions,

3M Quest products are only available for sale within our

Midwest regional territory.

They can be rented anywhere within the US.

Kit includes monitor unit, 9V

Alkaline battery, water bottle, serial interface cable, sensor bar containing wet bulb (WB), dry bulb (DB), 2" global temperature

(GT), and humidity (%RH) sensors, calibration verification module, user manual, quick start guide.

Air Probe-9 kit includes flow

sensor, two NiMH batteries, 120

VAC dual charger and storage case.

QUESTemp II Personal Heat Stress Monitor

• Detects a worker's individual physiological response to prolonged heat exposure, measures and records core body temperature

• Temperature sensor measures 89.6° to 104° F with ±0.2° F accuracy

• Minute-by-minute datalogging for documentation of personal heat exposure, including time stamp, detailed time history data, and overall summary data

• UL/CSA approved intrinsically safe for use in potentially hazardous areas

• User-selected alarm trip points give audio alert at elevated core temperatures

Models and Accessories for Sale

Description

Intrinsically safe personal heat stress monitor kit

Catalog No

QT-II

Price

$1947.00

Rent by the day, week, or month.

See page 579.

Ships with monitor, cable for

ear sensor, thermoplastic earmold with speaker assembly, 10 replacement expandable foam ear plugs, digital oral thermometer, 10 disposable thermometer sheaths, serial cable, and storage case.

FIXED GAS DETECTIOn & MOnITOrInG

Products in this catalog are available to rent anywhere in the US. Due to representative agreements with our manufacturer partners, not all products are available for sale in all areas and markets. Prices are current at publication, and are subject to change without notice.

See

Page

Flame Detection Transmitters

Honeywell Fire Sentry FS20X Multi-Spectrum Fire and Flame Detector

Honeywell Fire Sentry FS24X QuadBand Triple IR Flame Detector

556

556

Gas Detection Transmitters

Honeywell Searchline Excel Open Path Gas Detection Systems

Honeywell Sensepoint XCD Gas Detection Transmitters

553

548

Honeywell Searchpoint Optima Plus Gas Detection Sensors 547

Honeywell Series 3000 MkII Intrinsically Safe Gas Detection Transmitter 552

Honeywell XNX Universal Gas Detection Transmitter

RAE Systems MeshGuard Wireless Gas Detector

546

554

Gas Detection Monitors and Controllers

Honeywell E3Point Toxic and Combustible Gas Monitor

Honeywell HA20 and HA40 Multichannel Digital Gas Controllers

Honeywell HA71 8-Channel and 16-Channel Digital Gas Controller

Honeywell HA72 Multichannel Digital Gas Controller

Honeywell Manning AirScan IR Carbon Dioxide Monitor

Honeywell Midas Single Gas Monitor with Internet-Based Controls

Honeywell Vulcain 301C Three-Channel Digital Controller

Honeywell Vulcain 301EM ASHRAE-Compliant Refrigerant Monitor

RAE Systems FMC 2000 Wireless Multichannel Controller

reference Materials

Properties of Common Flammable Gases

Properties of Common Toxic Gases

491

491

558

549

550

551

553

552

557

557

554

545

Ordering Calibration Gases

Because of their classification as hazardous materials, calibration gases are not included with any of our instruments. You can contact

RAECO to order them separately. Please note that all calibration gas orders will be subject to handling charges and HazMat shipping fees, and will ship to you directly from the manufacturer.

RAECO rents portable gas monitors

Looking for a portable single-gas or multigas monitor to use for a short-term project? RAECO rents portable gas detectors on a daily, weekly, or monthly basis.

Rent online at www.RAECORents.com, and we'll pay the round-trip UPS Ground shipping!

No paperwork. No codes to remember or forms to fill out! Just click and save.

546

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

XNX Universal Gas Detection Transmitter

Features

• Robust and reliable operation in harsh environments

• Universal detector unit supports mV (catalytic bead and IR cell), electrochemical cell and IR

(point and open-path) gas detection

• 4-20 mA with HART® standard; Communication options include up to 3 relays, MODBUS® and

FOUNDATION® H1 Fieldbus (pending); Optional local IS port for handheld HART configurator

• Large, backlit, easy-to-view LCD display offers multisensory indicators (visual icons, colored buttons, text) to display gas and sensor readings

• Self-test and fault indication features; Quick calibration

XNX is designed for flexible integration, simple installation, user friendly operation and straightforward maintenance. A powerful advanced communications module adds increased functionality and flexibility to a gas detection network. Standard HART communications, along with optional Modbus, Foundation Fieldbus or relays, interface with a PLC.

Learn more online at www.Raeco.com/get/XNX.php

The XNX enclosure is available in a painted stainless steel or aluminum housing with a marine grade coating. Rugged mounting options provide ultimate installation flexibility.

Sensor instrumentation can be attached locally to the transmitter or remotely with the appropriate accessories. Inside, customer and sensor connections to the unit are designed to protect against dangerous electrical misconnections. With pending approvals to UL, CSA and

ATEX requirements for Hazardous Locations, and IP66/67 rating to protect against dirt/water ingress, the XNX serves the most demanding industrial environments.

Condensed Specifications

Enclosure: Painted aluminum or 316 stainless steel, five conduit/cable entries; NEMA 4X/IP65 rated

Interface: Backlit 2.5” tall LCD high resolution dot matrix display with discrete alarm and status indication; Reliable non-intrusive four-button interface with magnetic wand access. HART handheld with IS port optional

Display: Gas reading, gas name and engineering units, fault and alarm status, large numeric concentration or LEL display, bargraph showing current reading, setpoints and full scale; Fault/ alarm and operating status indication: Security settings allow multi-level operator access for setup, configuration and calibration; Event history stores time and date of all alarm, diagnostic, and configuration events

Output Signal: Standard HART over three-wire, 4-20 mA. Optional Form C and three 5A SPDT relays

(two alarm, one fault); Modbus over RS-485 and Foundation Fieldbus (not available with relays

Approvals: Hazardous Area: UL: Class I, Div 1, Groups B-D, Class 1, Zone 1, AEx d IIC T5; CSA: Class I, Div

1, Groups B-D, T5; Performance: UL 913, UL 1203, CSA 22.2 #152 pending; SIL 2

Honeywell XNX Series Gas Sensors and Ranges

Gas Type

Acetylene IR

Ammonia

Arsine

Bromine

Carbon Dioxide IR

Carbon Dioxide

Carbon Monoxide

Chlorine

Range

0–2.5%

0–100 ppm

0–1000 ppm

0–2 ppm

0–5 ppm

0–5000 ppm

0–2%

0–5%

0–100 ppm

0–500 ppm

0–1000 ppm

0–5 ppm

0–10 ppm

0–20 ppm

Gas Type

Chlorine Dioxide

Diborane

Ethylene Oxide

Fluorine

Germane

Hydrogen

Hydrogen Cyanide

Hydrogen Chloride

Hydrogen Fluoride

Hydrogen Sulfide

Range

0–3 ppm

0–50 ppm

0–10 ppm

0–5 ppm

0–3 ppm

0–1000 ppm

0–50 ppm

0–50 ppm

0–10 ppm

0–10 ppm

0–50 ppm

0–100 ppm

0–500 ppm

Gas Type

Hydrogen Sulfide

Nitric Oxide

Nitrogen Dioxide

Oxygen

Phosphine

Silane

Sulfur Dioxide

Range

Solid State

0–100 ppm

0–10 ppm

0–10%

0–25%

0–2 ppm

0–25 ppm

0–25 ppm

0–100 ppm

Gas Type Range

Combustible Gases (0–100% LEL)

Natural Gas & H2

Petroleum Vapors

Solvents

IR for Methane

IR for Propane

ATEX 4.4% CH4, Natural Gas & H2

ATEX 1.7% Propane Petroleum Vapors

ATEX 1.7% Propane Solvents

IR Methane, ATEX 4.4% CH4

IR Non–Methane, ATEX 1.7% Propane

Oxygen

Solvent-Tolerant

Solvent/CO2-Tolerant

Low

Low, Solvent-Tolerant

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

547

A complete XNX model consists of the following:

1 An XNX transmitter base station

2 Your choice of electrochemical cell, infrared, or mV sensors

Start with your XNX-A model, and then add the necessary number of sensors as individual line items. Example: XNX-ATAE-RHNNN with one each XNXXSC1SS and XNXXSS1SS sensors.

Model Selection Guide

Description

UL Approved XNX Transmitter Base Station

Enclosure Aluminum, 3/4" NPT threads

316 Stainless steel, 3/4" NPT threads

Sensor

Type

Electrochemical cell

Infrared (combustible gas) milliVolt

Output

Interface

None

Relay

Modbus

Foundation Fieldbus (pending)

Local

Interface

None

Local HART® (requires handheld)

Spare Magnetic Wand/Screwdriver

Catalog

Number

Avail­ ability Price

XNX-A _ _ _-

• • •

$0.00

_ TA _-

_ TS _-

_ _ _ E-

_ _ _ I-

_ _ _ V-

N _ _ _ _

R _ _ _ _

M _ _ _ _

F _ _ _ _

150.00

250.00

825.00

515.00

515.00

0.00

100.00

120.00

500.00

_ NNNN

_ HNNN

1226-0254

• • •

0.00

200.00

8.00

If you picked sensor type E, select your electrochemical cell sensors below.

Description

Catalog

Number

Electrochemical cell (EC) toxic and oxygen sensors for

XNX universal transmitter

Avail­ ability Price

Oxygen, 0–25% volume

Carbon Monoxide

Hydrogen Sulfide, 0-15/10-50 ppm

Hydrogen Sulfide, 0-100 ppm

Chlorine

Sulfur Dioxide, 0-15 ppm

Sulfur Dioxide, 0-50 ppm

Chlorine Dioxide

Hydrogen, 0–1000 ppm

Hydrogen, 0–10000 ppm

Phosphine

XNXXSO1SS

XNXXSC1SS

XNXXSH1SS

XNXXSH2SS

XNXXSL1SS

XNXXSS1SS

XNXXSS2SS

XNXXSX1SS

XNXXSG1SS

XNXXSG2SS

XNXXSP1SS

Replacement toxic and oxygen sensor cartridges for EC sensors

Oxygen, 0–25% volume

Carbon Monoxide

Hydrogen Sulfide, 0-15/10-50 ppm

Hydrogen Sulfide, 0-100 ppm

Chlorine

Sulfur Dioxide, 0-15 ppm

Chlorine Dioxide

Hydrogen, 0–1000 ppm

Hydrogen, 0–10000 ppm

Phosphine

S3KO1SS

S3KC1SS

S3KH1SS

S3KH2SS

S3KL1SS

S3KS1SS

S3KX1SS

S3KG1SS

S3KG2SS

S3KP1SS

$400.00

400.00

400.00

400.00

500.00

500.00

500.00

500.00

500.00

500.00

600.00

225.00

225.00

225.00

225.00

325.00

325.00

325.00

325.00

325.00

400.00

Accessories for EC sensors

XNX Remote EC Sensor Mount Kit

Calibration Gas Flow Adapter Kit

S3KRMK

S3KCAL

499.00

60.00

HArT® Handheld Communicator

Fast startup, long battery life on standard batteries. Holds hundreds of device files and configurations! Download new DOF and firmware updates from www.Meriam.com.

Communicator with 3-Year Device File Download Subscription

General Service HART Communicator ....... MFC4150-01 .....$4095.00

Intrinsically Safe HART Communicator ...... MFC4150X-01 ..... 4310.00

If you picked sensor type I, select your infrared sensors below.

Description

Output

Ethylene calibration

Add HART Output (Change N to H)

Standard

With remote gassing cell

With remote gassing cell and

flow housing

Additional Non-

Standard Calibrations for Optima Plus IR

Combustible Gas

Detection Sensors

(100% LEL

Unless Specified)

Acetone

Band A High IR

Band B High IR

Band C Medium IR

Band D Low IR

Benzene

Butanone (MEK)

Cyclohexane

Cyclohexanone

Di-Methyl Ether

Ethyl Acetate

Methane

O-Xylene

Propane

Propane, 60% V/V

Propylene

P-Xylene

Styrene

Toluene

Catalog

Number

UL Approved Optima Plus Infrared Combustible Gas Detection Sensors: Configured as current source output, standard

with dust barrier, weather housing, and deluge/heat shade

Hydrocarbon calibration

Standard

With remote gassing cell

With remote gassing cell and

flow housing

2108N4100N

2108N4110N

2108N5100N

2108N4101

2108N4111

2108N5101

2108D3012

2108D3150

2108D3151

2108D3152

2108D3153

2108D3227

2108D3022

2108D3024

2108D3026

2108D3059

2108D3030

2108D3001

2108D3044

2108D3004

2108D3102

2108D3006

2108D3054

2108D3228

2108D3042

Avail­ ability Price

$1506.00

1563.00

1760.00

100.00

172.00

172.00

172.00

172.00

172.00

172.00

90.00

90.00

90.00

90.00

172.00

0.00

172.00

0.00

90.00

172.00

172.00

172.00

172.00

1455.00

1510.00

1700.00

Accessories for Optima Plus IR combustible gas sensors

Gassing Cover (for Calibration)

Calibration Cap

Universal Duct Mounting Kit

2108D0258

2108B0272

2442-0016

142.00

205.00

651.00

If you picked sensor type V, select your milliVolt sensors below.

Description

Replace -NNN in the XNX model number with the code below.

MPD-AM Catalytic Bead, %LEL

MPD-AMIF1 IR %LEL Flammable

MPD-AMIV1 IR CH4 0-5% Volume

MPD-AMIC1 R CO2 0-5% Volume

Replacement Cartridges for MPD Sensors

Catalytic Bead Cartridge, %LEL

IR Cartridge, %LEL Flammable

IR Cartridge, CH4 0-5% V/V

IR Cartridge, CO2 0-5% V/V

Accessories for milliVolt sensors

Gassing Cover (for Calibration)

Calibration Cap

Universal Duct Mounting Kit

Catalog

Number

CB1

IF1

IV1

IC1

1226A0359

1226-0300

1226-0299

1226-0301

2108D0258

2108B0272

2442-0016

Avail­ ability

Price

$590.00

800.00

800.00

800.00

300.00

400.00

400.00

400.00

142.00

205.00

651.00

548

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sensepoint XCD Gas Detection Transmitters

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Features

• Common transmitter platform — One transmitter works with a variety of sensors, so you stock fewer spares and spend less time training operators

• SureCell® electrochemical sensors, Poison-immune infrared sensors; Poison-resistant catalytic bead sensors; Long life sensors

• IP66 Stainless steel or aluminium explosion-proof housing

• Three-color backlit LCD with digits, bargraph and icons

• Fully configurable via magnetic switches

• MODBUS communications for remote diagnostics/ configuration, and multi-drop option for saving cable costs

• UL/CSA approved; Also available with INMETRO, ATEX,

IECEx, KTL, PA, GB and CCCF approvals

Flashing Red = Alarm

Yellow = Fault or warning

Green = Normal operation

Honeywell's Sensepoint XCD transmitter provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, indoors and outdoors.

The transmitter can auto-recognize any XCD-compatible installed sensor. The sensor plugs into the bottom of the transmitter, and the transmitter configures itself accordingly. You can modify detector operation via the LCD and magnet switches without ever opening the unit. This enables one-man, nonintrusive operation and reduces routine maintenance time and costs.

A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, yellow indicates fault and red indicates an alarm.

All detectors are supplied pre-configured and include two programmable alarm relays, one programmable fault relay plus 4-20 mA output (sink or source selectable) and Modbus communications.

The scale, range, relay operation, alarm setpoint and detector's electronic tag number can be adjusted in the field. Outputs are automatically inhibited during adjustment, reducing the risk of false alarm at the control panel during maintenance.

Condensed Specifications

Interface: Backlit color LCD display with alarm and status indication; Non-intrusive interface with magnetic wand access

Output: 4–20 mA current (source or sink), three 5A relays, configured normally open or normally closed and energized/deenergized; RS-485 Modbus

Detectable Gases

Gas

Type Span/Range

Default

Range Step

Acceptable

Cal Gas

O2

H2S

25.0% Vol —

10.0–100.0 ppm 50 ppm 1 ppm

20.9% Vol Fixed

CO

H2

Methane

CAT or IR

CO2 IR

100–1000 ppm 500 ppm 100 ppm

1000 ppm —

20.0–100% LEL 100% LEL 10% LEL

2.00% Vol —

30–70% selected full scale range

(typically 50%)

Enclosure: IP66-rated epoxy-painted aluminum alloy or 316 stainless steel

Input Voltage: 16–32 VDC (24 VDC nominal)

Approvals: UL, cUL, CSA

Model Selection Guide

Description

UL/CSA Approved XCD Transmitter, 4-20 mA

Output plus Three 5A Relays and Modbus RTU

Enclosure

Material

Aluminum, 3/4" NPT Threads

316 Stainless Steel, 3/4" NPT Threads

Sensor Type and Gas

Selection

Accessories

Oxygen, 25% Volume

Hydrogen Sulfide, 0-50 PPM

Carbon Monoxide, 0-500 PPM

Hydrogen,0-1000 PPM

Flammable, CAT, 0-100% LEL

Flammable CH4 IR, 0-100% LEL

Carbon Dioxide IR, 0-2% Volume

Replacement

Cartridges

Oxygen

Hydrogen Sulfide

Carbon Monoxide

Hydrogen

Flammable CAT

Flammable IR (Methane)

Calibration Cap

Collecting Cone (for Light Gases)

Mounting Bracket

Sunshade/Deluge Protection

Printed User Manual, English

Catalog

Number

SPXCDU_ _ _ _

Price

$0.00

LN _ _

SN _ _

_ _ O1

_ _ HX

_ _ CX

_ _ G1

_ _ FX

_ _ RX

_ _ B1

SPXCDXSO1SS

SPXCDXSHXSS

SPXCDXSCXSS

SPXCDXSG1SS

SPXCDXSFXSS

SPXCDXSRXSS

S3KCAL

SPXCDCC

SPXCDMTBR

SPXCDSDP

SPXCDHMANEN

0.00

210.00

979.00

979.00

979.00

979.00

874.00

1084.00

1049.00

315.00

315.00

315.00

450.00

285.00

550.00

60.00

60.00

55.00

220.00

30.00

RAECO LIC-LLC www.RAECO.com [email protected]

Two-channel

HA20

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

549

HA20 and HA40 Multichannel Digital Gas Controllers

Four-channel

HA40

Features

• Accepts inputs from two or four 4-20 mA sensors transmitters

• Internal 24 VDC power supply provides 15 watts total system power

(50 watt supply available)

• Three independent alarm levels per channel. Relay Acknowledge feature allows silencing of external audible devices during existing alarm conditions

• Two SPDT common alarm relays for HORN, HIGH, WARN or FAULT

• Graphic LCD readout displays monitored data as bargraphs, trends and engineering units. Alarm LEDs flash when new and become steady after acknowledged

• Touch and magnetic keypad for non-intrusive operation in potentially hazardous locations

• Optional Modbus slave RS-485 serial port, data logging, 4-20mA outputs, and discrete alarm relays

• CSA certified to C22.2 NO. 152 for combustible detection and Class

I, Div. 2, Groups A-D, CE

• NEMA 4X (Div. 2 certified) and Explosion-Proof wall mount packaging options available

Honeywell digital gas controllers are designed to work in the harshest industrial or commercial environments to monitor for toxic gases, combustible gases, and oxygen deficiency. Honeywell HA20 and HA40 models provide simultaneous display and alarm functions for up to four sensor transmitters. Both can function as standalone devices or can be integrated into a fire and gas system.

HA20 and HA40 controller graphic LCD display shows monitored data as bargraphs, 30-minute trends, and engineering units. A touchand-magnetic keypad allows for non-intrusive operation in potentially hazardous locations. Cal Mode offers pushbutton zero/span calibration for direct sensor interface applications. Authorization Mode lets you protect critical configuration variables from accidental changes.

The 4-20 mA inputs are ideal for interfacing to sensor transmitters mounted far away from the controller. Relay outputs allow control of beacons, horns and other alarm events. Three adjustable alarm levels are provided per channel. Two standard SPDT common alarm relays are for

HORN, HIGH, WARN or FAULT alarm conditions.

Specifications

Display: 128 x 64 pixel graphic LCD with backlight displays, bar graphs, trends and engineering units

Alarm Relays: 5-amp, 30 VDC or 250 VAC resistive, Form C;

Common: Two standard; Discrete: Six optional

Analog Output: 10 bit. Max load 800Ω, nominal 24 VDC power

Power Requirement: 100-240 VAC / 24 VDC standard

Operating Temperature Range: -13° to 122° F

Housing: Wall mount; NEMA 4X/IP66 wall mount, Div 2; NEMA 7 explosion-proof, Div 1 & 2; NEMA 4X SS Enclosure, Div 2

Approvals: CSA C22.2 No. 1010.1 & ISA S82.02; UL 1604 / C22.2

No 213 (NEMA 4X: Div 2 Groups A-D, NEMA 7: Groups B-D);

EN55011 & EN61000

Wireless Options: Optional HA40 900MHz wireless interface

(10-2454) can be used to communicate with an HA71 master

Modbus controller. An additional 900MHz wireless adapter is also required for the HA71 (10-0288).

Model Selection Guide

Description

Catalog

Number

Avail­ ability Price

Honeywell digital gas controller with six discrete relays, internal 50W power supply, two common relays

Inputs and Enclosure

Two 4-20 mA inputs, NEMA 4X enclosure

Four 4-20 mA inputs, NEMA 4X enclosure

Two 4-20 mA inputs, painted steel enclosure

Four 4-20 mA inputs, painted steel enclosure

Two 4-20 mA inputs, stainless steel enclosure

Four 4-20 mA inputs, stainless steel enclosure

HA20PY

HA40PY

HA20PCS

HA40PCS

HA20SS

HA40SS

$1979.00

2356.00

2054.00

2431.00

3379.00

3756.00

I/O Options (Choose Up to 3)

Dual 4-20 mA analog input

Dual 4-20 mA analog output

Combo bridge sensor/EC sensor input

Dual bridge sensor input

Quad 4-20 mA analog input

Quad 4-20 mA analog output

Quad bridge/Dual analog sensor input

RS-232/RS-485 Modbus RTU interface

Six 5-amp Form C relay option

Accessories

10-0221-2

10-0223

10-0216

10-0219

10-0221-4

10-0308

10-0309

10-0253

10-0222 •

100.00

146.00

134.00

144.00

112.00

226.00

265.00

218.00

172.00

Div 2 red Xenon strobe light and mount

Div 2 amber Xenon strobe light and mount

100 dB piezo audible alarm

50W NEMA 4X Div 2 internal power supply

550VA/300W UPS/surge protector with

power loss relay

10-0284

10-0285

10-0337

10-0315

10-0287

• 473.00

473.00

106.00

383.00

983.00

Need control for more inputs? See pages 550 and 551 for 16-to-64 channel digital gas controllers.

550

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

HA71 8-Channel or 16-Channel Digital Gas Controller

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Features

• Accepts up to 16 inputs from numerous sensor types — analog or Modbus, allowing data retrieval via RS-485, for reduced wiring cost at installation

• Eight-channel display mode and option boards for economical configuration of systems requiring eight channels or fewer

• Cal Mode offers pushbutton zero/span calibration for direct sensor interface applications

• Graphic LCD displays monitored data as trends, bargraphs, and engineering units

• Standard type A SPDT common alarm relays for Horn, High, Warn, and Fault

• Three adjustable alarm levels per channel

• Relay Acknowledge feature silences external audible devices during existing alarm conditions

• HMI software monitors up to ten HA71 controllers simultaneously

Honeywell's HA71 controller delivers advanced value through simultaneous display and alarm functions for up to 16 input variables. In addition to the graphic LCD and three adjustable alarm levels per channel, relay outputs allow control of beacons, horns, and other alarm events. Horn relays can be set for steady or pulsing operation.

The HA71 is easy to configure and use. Measurement ranges in engineering units, adjustable alarm setpoints, dual serial interfaces, and other selectable features combine to let the HA71 satisfy the needs of many demanding applications. It is widely used for centralizing the display and alarm processing functions in critical multipoint monitoring applications, including monitoring of ambient gas detection, rotating machinery, tank levels, flow, temperature, and others.

HA71 options, such as discrete alarm relays per channel, 4–20 mA I/O, direct sensor input conditioning and others, are added by connecting appropriate eight-channel boards to the I2C expansion bus.

HA71's human machine interface software has the ability to monitor up to ten HA71 controllers simultaneously, displaying up to 160 points of detection. It provides complete data display and storage, with real-time channel data available in 24-hour or 15-minute trends, including historical alarm and maintenance data.

Condensed Specifications

Power Requirement: 10–30 VDC, 24 VDC nominal; 12 watts max

Analog Inputs: 12-bit, 4–20 mA into 100 ohms input impedance;

Includes power supply terminals for each channel, for routing power to two-wire or three-wire transmitters

Serial Ports: Modbus RTU master and slave RS-485 half or full duplex ports equipped with Tx/Rx LEDs

Alarm Relays: 5 amp 30 VDC or 250 VAC resistive form C

Analog Outputs: 10-bit 4–20 mA; 800 ohm max load with nominal

24 VDC power supply

Display: 128 x 240 pixel backlit graphic LCD; Displays bargraphs, trends, and engineering units, 52 discrete LEDs indicate alarm status for three alarms per 16 channels and common relays

Operating Range: -13° to 140°F (-25° to 60°C)

Housing: NEMA 4X fiberglass enclosure; NEMA 7 explosion-proof wall mount model also available. Call for pricing

Approvals: CSA: C22.2 #1010.1, 152 for combustibles; ISA S82.02;

UL: 1604/C22.2 #213, Div 2, Groups A-D; CE EN55011, EN61000

Need help building the HA71 model you need?

Call RAECO inside sales at 800-852-9795.

A complete HA71 model consists of the following:

1 An HA71 enclosure and base control unit. The enclosure can hold up to seven I/O cards in any combination.

2 A universal power supply, unless you are providing your own 24

VDC power source.

3 Your choice of input and output boards. If you choose more than three I/O cards, you must also order a 10-0180 expansion plate.

If you choose more than seven I/O cards, you will also need a 10-

0178 expansion enclosure, which holds up to eight option cards.

Model Selection Guide

Description

Catalog

Number Price

8-Channel Digital Gas Controller, NEMA 4X Enclosure

16-Channel Digital Gas Controller, NEMA 4X Enclosure

Power

Input

Cards

(Max 16

Inputs)

Output

Cards

Expansion

Options

Hardware

Alarms

85-240 VAC Universal Input, 24 VDC Supply 10-0172

Analog 8-Input Board with EXC Terminals

Catalytic Bead/LEL Sensor/mA Input Board

Dual Catalytic Bead/LEL Module

RTD/Resistive/4-20 mA 8-Input Board

Form C Relay for ALM1, ALM2, Horn

8 4-20 mA Output Board

8 Form C 5 Amp Relays for Discrete Alarms

Expansion Plate (Adds 4 Card Positions)

Expansion Enclosure (Holds 8 Option Cards)

100 dB Piezo Audible Alarm on Enclosure

Amber/Red Light with 80 dB Horn

Human-Machine Interface Software Package CD

HA71N4-8

HA71N4-16

10-0158

10-0191

10-0192

10-0170

10-0144

10-0167

10-0195

$5451.00

6573.00

490.00

330.00

413.00

200.00

495.00

126.00

330.00

366.00

10-0180

10-0178

1000-1892

1000-1906

120.00

525.00

158.00

750.00

HA-71-HMI 3276.00

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

551

HA72 Flexible Multichannel Digital Gas Controller

Features

• Accepts 16 to 64 inputs from many sensor types and signal ranges. Daisy chain up to 128 HA72 controllers to expand the system to meet your needs

• Custom software auto-recognizes and addresses Honeywell gas sensor transmitters (XNX™ and Sensepoint XCD)

• Connect sensors directly to HA72 with bridge sensor input board, saving installation time and eliminating need for extra devices

• Visual indicators (bargraphs, multi-color cells, flashing icons) and integrated alarm levels simplify and enhance monitoring, troubleshooting and trending

• Touch-and-magnetic keypad for non-intrusive operation in hazardous areas

• Enclosures for hazardous and non-classified areas : NEMA 4X, full/half 19” rack mount, NEMA 4X stainless steel, and NEMA 7 explosion-proof wall-mount

• SD card logs over one year of data including concentration levels, alarm events, min/max, calibrations and alarm resets

Main data screen shows all active channel inputs,

• Modbus master/slave functionality allows for simultaneous sending and receiving of data, through four RS-485 serial ports

in 16, 32, 48, or 64 active channels, and show alarm status by color.

The HA72 controller is a flexible, scalable gas controller that works the way you need it to. The HA72 puts you in control of mission-critical information and lets you share it across the enterprise via a secure, password-protected interface.

Know exactly what’s happening with your gas monitors, at all times, from anywhere. An embedded web server provides interface and remote system configuration for the HA72. The

Modbus TCP port lets you remotely configure and view the HA72 display via your Ethernet network.

View, Access, Share and Store Your Data Easily

You can upload/download system configuration via SD card, download the SD card onto additional HA72s for uniform configuration and to cut commissioning time across your safety system. Plus, you can log over one year of gas data for compliance and other safety reports and audits.

Main Data Screen: Displays ALL active channels on the same screen. Channel configurations include 16, 32, 48 and 64 active channels. Cells indicate alarm status by color. (See above right.)

Bargraph Screen: Displays 16 channels at a time. Side scroll bar controls which group of 16 channels are visible. Bar graphs change colors to indicate alarm status.

Zone Screen: Displays eight possible active zones. Alarm cells change colors and name field flashes indicating alarms. Simple interface lets you review which channels belong to each zone.

A complete HA72 model consists of the following:

1 An HA72 enclosure, base control unit. The HA72 comes standard with magnetic keypad, I/O interface board (two RS-485 ports, one

Ethernet port, five relays), and a 2GB SD memory card.

2 A universal power supply, unless you are providing your own 24 VDC power source.

3 Your choice of input and output boards. If you choose more I/O cards than the base can support, order an expansion plate.

Model

Standard I/O Board

Supported

I/O Boards Expanded

Total with Plate

Expansion

Plate

72-01

72-02

72-04

72-05

72-07

Two

Four

Seven

Seven

One

Five

Seven

Eleven

Eleven

0010-0321

0010-0321

0010-1269

0010-1269

Condensed Specifications

Display: QVGA 320 x 240 pixel backlit color graphic LCD; Discrete

LEDs indicate alarm status for five standard alarm relays

Alarm Relays: 5 Amp 30 VDC or 250 VAC resistive Form C

Analog Inputs: 12 bit 4-20mA into 150Ω input impedance

Analog Output: 10 bit 4-20mA output; max load 800Ω with nominal 24 VDC power supply

Ethernet Port: Modbus TCP Master/Slave port

Serial Port: Modbus RTU, Master/Slave, RS-485 half or full duplex ports with Tx/Rx LEDs

Power Requirement: 10–30 VDC (24 VDC nominal) 12 Watts max

Approvals: Class I, Div. 2, Groups A-D; CSA-C22.2 No.152-M1984,

CSA-C22.2 No. 213-M1987; ANSI/ISA-12.13.01-2000; UL Std No.

1604, Third Ed. – 1994; ANSI/ISA-12.12.01-2010

Need help building your HA72 controller? Call

RAECO inside sales at 800-852-9795.

Model Selection Guide

Description

Catalog

Number Price

HA72 digital gas controller (32, 48, or 64 channels), includes magnetic keypad

Controller

Enclosure

Power

Inputs

(Max 64)

Panel mount rack controller

Controller in full 19" rack

NEMA 4X fiberglass enclosure

NEMA 4X 316 stainless steel enclosure

NEMA 4X compact non-metallic enclosure

72-01

72-02

72-04

72-05

72-07

85-240 VAC universal input, 24 VDC supply 10-0172

I

2

C analog 16 input board

I 2 C bridge sensor/mA input board

Dual bridge sensor module (req. 10-0347)

10-0344

10-0347

10-0192

$10320.00

11320.00

11640.00

14240.00

11000.00

490.00

Outputs

Auxiliary alarm relay board (+5 relays)

I 2 C analog 16 output board

I

2

C 16 discrete alarm relay board

I 2 C 16 programmable alarm relay board

RS-485 isolated expansion board (+2)

Expansion

Plates

Expansion plate (Adds 4 option cards)

NEMA 4 expansion plate (Adds 5 cards)

10-0332

10-0344

10-0348

10-0350

10-0368

0010-0321

0010-1269

952.00

1120.00

200.00

312.00

952.00

952.00

1336.00

512.00

280.00

312.00

552

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Proven Gas Detection and Control Applications

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Low-Cost Oxygen Monitor for Lab Worker Safety

Application

• Pharmaceutical customer uses pure nitrogen in its lab for analytics and cold calibration, and needed a simple, low-cost oxygen monitoring system to ensure worker safety.

• Goals were (a) ease of installation, (b) ease of integration into the existing plant system, and (c) low maintenance.

Midas Gas Monitor with Built-In

Web Server

Application Toolkit

For help building an oxygen monitoring system like this one, please call 800-852-9795 and speak with your RAECO account manager.

Learn more about

Honeywell Analytics fixed gas detection instruments online at www.RAECO.com

Solution

• Customer installed the Midas oxygen sensor using Power over Ethernet, a single Ethernet connection providing all power, control and communications requirements. They monitored instrument status and alarm values via the website and used the internal relays on the Midas to drive local alarms, strobes and ventilation.

• Maintenance team opted to use Honeywell Analytics customer support program to reduce issues with sensor failure and disposal of worn sensors. Midas' auto-sensor diagnostics and LCD help keep lab workers and maintenance team informed.

Results

• System was installed and running in less than an hour

• Lab workers have easy access to key information through a standard web browser

• Pre-calibrated sensor and pump modules contribute to simple, low-cost maintenance

Honeywell Analytics Plug-N-Play Smart Sensors with Reflex® Technology

Honeywell pre-calibrated sensor modules are ready to use, right out of the box. These self-diagnosing sensors can be replaced in hazardous areas — with power applied — without the need for special tools.

Imagine how much maintenance and downtime you'll save when you don't have to clear the area and stop production just to change a sensor!

Only Honeywell’s patented Reflex technology adds an extra degree of precision and diligence to sensor monitoring to make doubly sure that people are kept safe. Reflex bounces electrical signals into the Midas electrochemical sensor at regular intervals, a form of electronic bump testing and continuous monitoring of sensor cell response.

Call RAECO to learn more.

Loop-Powered Intrinsically Safe Toxic and Oxygen Gas Detector

Features

• Proven plug-and-play factory-configured long life electrochemical sensors, patented Reflex® sensing element verification diagnostics

• Sensor recognition software automatically configures transmitter with plug-and-play factory configured sensors

• Uses SureCell™ electrochemical cells, ideal for hot and humid environments

• Explosion-proof transmitter allows field wiring to be run along with other non-IS instruments

• Configure without a Hot Work Permit using the LCD and magnetic switches

• Intrinsically safe sensor connection permits hot swap, reducing downtime and maintenance

• UL, cUL, ATEX, and IEC Ex approved

Honeywell's Series 3000 MkII transmitter provides comprehensive monitoring of toxic and oxygen gas hazards in potentially explosive atmospheres, both indoors and out. This gas detector operates on an industry standard two-wire 4-20 mA loop, making it ideal for both new and retrofit applications.

You can configure the detector using the LCD and magnetic switches — no need for a hot work permit.

Fault diagnostic software and programmable calibration frequency simplifies maintenance procedures.

Series 3000 MkII with Reflex® Sensor

Technology

A remote sensor mounting kit is available for mounting the sensor up to 50 feet from the transmitter, making it ideal for operation in areas that are difficult to access.

Call RAECO to learn more.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

553

AirScan IR for Severe

Environment Use

Application Toolkit

For help building a CO2 monitoring system like this one, please call

800-852-9795 and speak with your

RAECO account manager.

Monitoring CO2 in Food and Beverage Production Plants

Application

• Many applications in the food and beverage industries generate carbon dioxide (CO2) during production — particularly in fermentation, freezing, baking, and food packaging.

Systems also available for refrigerant and ammonia monitoring.

• Because long-term exposure represents a serious health hazard, it's mandatory to monitor CO2 releases in these production and packaging areas.

• Facilities usually have areas that are wet or have high humidity, so any CO2 sensors — which have to be mounted near the floor to properly detect gas accumulation — must be able to withstand sustained exposure to moisture.

Solution

• AirScan IR-F9 has a rugged steel enclosure and infrared sensor that ensures long-term, troublefree operation, unaffected by severe environments. It's washdown-safe and works in anything from -50° F to 100% humidity. SensorCheck™ technology continuously monitors sensor performance and checks voltage, internal circuitry, operating temperature, wire length and other operating elements.

Results

• Fast response and the ability to start exhaust fans makes AirScan IR ideal for CO2 monitoring.

• Factory-calibrated infrared sensor has warning levels set at 1% and alarm levels set at 2.5%. LCD readout and status LEDs inform workers of real-time concentrations.

• No-drift sensors help keep processes running, since false alarms and forced downtimes are dramatically reduced.

Call RAECO to learn more.

Systems for Monitoring Liquefied Natural Gas Applications

Application

• The high demand for natural gas has created the need for liquefied natural gas (LNG) facilities.

The typical LNG facility requires between 40 and 90 single-point infrared gas detectors, 30 to

60 infrared flame detectors, 10 to 15 open-path gas detectors, plus CO and O2 detectors, and a control system that's capable of running alarms, providing shutdown functions, and triggering foam or sprinkler fire suppression systems.

• Dock areas, storage tanks, liquefiers, and vaporizers require a combination of technologies for effective flame and gas detection. Offices and maintenance shop areas require infrared gas detection, as well as O2 and CO monitoring.

• Many plants use distributed control systems (DCS) for control and shutdown, but can benefit from the addition of a secondary fire and gas detection controller to monitor fire, gas, smoke, and thermal detectors.

Application Toolkit

For help building an integrated system like this one, please call

800-852-9795 and speak with your

RAECO account manager.

Solution

• Honeywell Analytics' FD series flame detectors are sensitive, self-contained "triple IR" sensors that can detect virtually any hydrocarbon fire, with high immunity to false alarms.

• The Searchpoint Optima Plus single-point gas detector continuously monitors combustible and carbon dioxide gases and vapors, and works reliably in high-gas and low-oxygen environments.

Its long-term stability and zero drift eliminates the need for frequent calibrations, reducing the total cost of ownership.

• Searchline Excel open path gas detection systems measure gas cloud concentration over a distance of up to 200 meters where gas concentrations are not uniform.

• The HA71 control system offers a new standard in flame- and gas-detection technology. It can monitor 4-20 mA output sensors, smoke detectors, and manual alarm call points. It offers signal processing for up to 16 inputs per controller.

Call RAECO to learn more.

554

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

MeshGuard Intelligent Wireless Gas Detection System

Features

• Multiple controller options for real-time wireless data collection and viewing

• Self-forming wireless network; Wireless field units come online automatically

• Self-healing network automatically routes data back to controller through best wireless path available

• Low maintenance field transmitters! Three consumable parts — battery, filter, and sensor — just one tool needed to perform all service

• Intrinsically safe field units, IP65 rated weather resistant, and splash guard equipped for sensor protection

• Magnetic mounting for quick and easy installation

• Battery powered operation for up to 6 months

• Compatible with ProRAE Guardian software platform

Keep your plant safe without the high cost of installation and wiring!

MeshGuard Battery-Powered

Wireless Gas Detectors

MeshGuard is the leading intelligent wireless gas detection system that is rapidly deployable in numerous industrial and remote monitoring applications. MeshGuard not only saves lives, but tens of thousands of dollars in regulation compliance and information processing.

MeshGuard wireless detectors are designed for use in the harshest outdoor environments.

MeshGuard combines the most advanced gas detection technology for industrial safety applications with the latest in connected data systems. Because the system includes powerful wireless sensors, MeshGuard eliminates the need for lengthy and costly installation projects. By detecting and recording a wide range of deadly gases and quickly relaying the data to an easy-to-understand central system, safety personnel have up-to-date information from throughout the network of sensors at a finger’s touch.

Sensor Ranges

Sensor

H2S

LEL

CO

O2

NH3

Cl2

SO2

Range

0–100 ppm

0–100%

0–2000 ppm

0–25%

0–100 ppm

0–10 ppm

0–20 ppm

Resolution

0.1 ppm

1%

1 ppm (0–500 ppm

10 ppm (500–2000 ppm)

0.1%

1 ppm

0.1 ppm

0.1 ppm

Response Time

T90 T10

<30 sec <30 sec

<30 sec <30 sec

<30 sec <30 sec

<15 sec <15 sec

< 90 sec <200 sec

<30 sec <30 sec

<60 sec <60 sec

Build a MeshGuard system with a wireless controller in the field, or expand control with a PC running ProRAE Guardian software

FMC 2000 Wireless Multi-Channel Controller

• Communicates with up to 24

MeshGuard wireless monitors

• Five programmable SPDT relay outputs

• NEMA 3, IP66 stainless steel enclosure

• Built-in wireless antenna and modem

• Five relays, visual and audible alarms

• RS-485 and Ethernet interface

FMC 2000 is a multi-channel controller designed for integration with RAE Systems’

MeshGuard intelligent gas detection sensors. The FMC 2000 gathers data and monitors alarms from MeshGuard toxic and flammable gas sensors.

The controller includes built-in security safeguards to resist tampering of critical parameters. The optional FA200 alarm bar adds one audible and four visual alarm outputs, all of which are fully configurable within the controller.

The unit comes standard with five sixamp SPDT relay outputs, and Modbus RTU communications. The stainless steel housing includes a rechargeable lead acid battery for up to 15 hours of operation when line power is not available.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

555

Mesh Router Wireless Range Extender and Deployment Tool

• Large area coverage with multi-hop mesh network

• Operating distance: up to 990 feet (300 meters), line-of-sight

• Mesh network with automatic network forming and configuration

• Low-cost installation — no hard-wiring involved

• Field-replaceable battery

• Easy-to-read display of signal strength, plus bright red flashing alarm

• Highly resistant to RFI interference

• IP65 rated for outdoor use in harsh environments

ProRAE Guardian Software

• Simultaneously monitors up to 500 instruments

• Intuitive user interface with simultaneous on-screen instrument readings

• Integrates with Google Maps for precision instrument locations and alarm status

• View map and multiple instrument readings simultaneously on the same display

• Real-time display of device status, sensor readings, and alarms

• Communicates remote alarms via e-mail and text messages

• Datalogging in text and graphical formats, including boolean filters

• XML and Modbus interface for easy integration into thirdparty systems

ProRAE Guardian represents an advanced generation of realtime wireless threat detection solutions. The program serves as a mobile command center for safety managers and incident commanders by connecting and relaying data from RAE Systems and select third party wireless products to remote locations anywhere in the world.

ProRAE Guardian accepts real-time detector data and instantly displays device status, alarm, and sensor reading information — all integrated on a single map display. Because ProRAE Guardian is always on and always connected, geographically dispersed teams can coordinate threat responses while simultaneously viewing the same situational data, all in real time.

The Mesh Router allows wireless sensor networks to be deployed at greater distances from a central controller. The Mesh

Router is a Class I, Div 1 (Zone 0) portable wireless device that extends wireless transmission range between points. MeshGuard monitors and routers work together to find the best possible transmission path for sensor readings.

As a system deployment tool, the Mesh Router displays the real-time wireless signal strength at any given location, for rapid determination of suitable mounting locations for MeshGuard monitors.

The Mesh Router is in constant communication with the FMC

2000 controller and MeshGuard detectors in the network, and can manager up to 12 detectors. The unit can operate continuously for more than 10 days with an internal battery, or more than 45 days with an external PowerPak rechargeable battery.

MeshReader for PC-Based Controllers

• Communicates with up to 24 remote monitors

• Receives data wirelessly from remote detectors and pushes data to ProRAE Guardian software on a PC

• Easily scalable system by merging multiple MeshReaders through the Internet

• Wireless mesh input, Ethernet and RS-232 data output for direct connection to PC or Ethernet network

• Designed for non-hazardous indoor locations. For outdoor applications, requires addition of an outdoor antenna and

30-foot cable

Call RAECO for help building your complete

MeshGuard wireless gas detection system.

556

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Fire Sentry Multi-Spectrum Fire and Flame Detectors

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

FS24X Multi-Spectrum QuadBand Triple IR Flame Detector

Features

• Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions

• Patented WideBand IR™ technology,

Electronic Frequency Analysis™

• Field of view: 90° full 100% cone of vision

±45° from ON axis or 110° full 100% cone of vision ±55° from ON axis

• Visible 400–700 nanometer spectral sensitivity (0.07 to 5.0 microns)

• Blue, red, and yellow LEDs alert you to power, alarm, and fault conditions

• Real-time clock for accurate timing of events

• RS-485 Modbus communication

• 0–20 mA stepped analog output (userselectable source or sink)

• SPST fault relay and SPDT fire alarm verification and auxiliary relays

• FirePic™ pre-fire event data storage plus event logs with time and data stamp

• FM Class I, Div 1 and 2, Groups B–D; Class II,

Div 1 and 2, Groups E–G, Class III approval

• ATEX II 2 G D; Ex d IIC approval

• Meets SIL 2 requirement (FMEDA available)

WideBand IR™ infrared technology with high-speed solid state

Quantum sensors detects hydrocarbon and non-hydrocarbon fires in all weather conditions. If the detector's signal is blocked by window glass, the patented WideBand IR sensors will still alarm to the fire, but at a reduced sensitivity and slower response time.

Dual microprocessors provide fail-safe operation with fast, reliable performance. The master microprocessor performs high speed digital sampling and signal processing calculations. The slave processor handles sensor data, performs communications, self-diagnostics, and provides interface versatility, with additional memory for storing event log and FirePic™ data.

The Fire Sentry FS24X has a detection range greater than 200 feet for the detection of a one-square-foot Heptane reference fire, and has a cone of vision far greater in volumetric coverage than any other multi-spectrum IR Detector. This means fewer detectors can be used to keep your plant safe.

Model Selection Guide

Description

Copper-Free

Aluminum Housing

316 Stainless Steel

Housing

Accessories

Field of

View

110°

90°

110°

90°

Temperature

Range

-40° to 85° C

-60° to 85° C

-40° to 85° C

-60° to 85° C

Catalog

Number

FS24X-211-21-1

FS24X-911-21-1

FS24X-211-22-1

FS24X-911-22-1

Price

$3190.00

2436.00

3442.00

2762.00

Stainless Steel Swivel-Mounting Assembly

Universal Charger for Test Lamps/Interface Kits

IR Test Lamp, Explosion-Proof Version

IR Test Lamp, Non-Explosion-Proof Version

Sun Shield

Field-of-View Restrictor

SM4

PSU-12

TL-2055

TL-1055

SH-001

FVR-01

184.00

128.00

2720.00

1172.00

127.00

99.00

Need help building a flame detector system? Call

RAECO and talk to a factory-trained specialist.

FS20X Multi-Spectrum UV/Dual IR/VIS Fire and Flame Detector

• Detection range >200 feet to 1 sq. ft. heptane fire; Selectable sensitivities

• WideBand IR™ Infrared plus ultraviolet

• FirePic™: Up to 6 pre-fire event data storage plus event log with date and time stamps

• Built-in RS-485 Modbus communication, 4-20 mA isolated analog output, sink or source

• Alarm, fault and fire verification relays

• High RFI and EMI immunity

• FM Approved Class I, Div 1, Groups A-D;

Class II, Div 1, Groups E-G; Class III; Also available with ATEX/IECEx Class I, Zone 1

• PC software and Interface Module (FSIM) for fault diagnostics, real-time graphs (RTGs), and downloading of FirePics™ and event log

• Two 3/4” NPT entries

Fire Sentry FS20X detector uses advanced patented algorithms for signal processing and fire and flame analysis, and is designed to alarm to all types of fires in all industrial environmental conditions.

If the detector’s UV signal is degraded by heavy smoke or a contaminated lens, the patented WideBand IR™, Near Band IR and

Visible sensors will still alarm to fire, but at a reduced sensitivity and slower response time.

The Fire Sentry FS20X has a range in excess of 200 feet for the detection of a one-square-foot Heptane reference fire, with a cone of vision greater in volumetric coverage than most UV/IR detectors, so you can use fewer detectors to cover a broader area.

Model Selection Guide

Description

Aluminum Housing

Stainless Steel Housing

Accessories

Field of

View

90°

Temperature

Range

-40° to 85° C

Stainless Steel Swivel-Mounting Assembly

Universal Charger for Test Lamps/Interface Kits

IR Test Lamp, Explosion-Proof Version

IR Test Lamp, Non-Explosion-Proof Version

Field-of-View Restrictor

Catalog

Number

FS20X-211-21-2

FS20X-211-22-2

Price

$2450.00

2754.00

SM4

PSU-12

TL-2055

TL-1055

FVR-01

184.00

128.00

2720.00

1172.00

99.00

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Above: Vulcain 301C three-channel controller. Below, clockwise from left:

301R output relay module ,301W wireless transmitter, and 301EM refrigerant gas monitoring system with visual and audible alarms.

ASHRAEcompliant refrigerant monitor

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

557

301C Three-Zone Digital Controller

Features

• Zero maintenance, automatic quick self-test at warmup

• Continuous alphanumeric display

• Interchangeable transmitters to detect different gases

Reduce wiring costs!

Wireless transmitters available with sensors for CO, O2, and NO2.

• Manages up to 768 events with programmable latching alarms

• Allows for up to 126 zoning groups to help save energy and extend fan and relay life

• Modbus compatible, BACnet/IP also available

• Expands to handle up to 96 transmitters or relay modules, and up to 50 301W wireless sensors

• Programmable time delays; Integrated time clock enables scheduling of system operations

• Full array of visual indicators and integrated 65 dBA alarm levels

• Programmable relays can be set for fail-safe operation

Honeywell's Vulcain 301C continuously monitors and controls toxic gases, combustible gases, and oxygen hazards. Using an addressable RS-485 Modbus communication protocol, the 301C uses daisy chain wiring, so it only takes two pairs of wires to connect up to 96 transmitters on the three input channels. This simplifies installation and significantly reduces operational and maintenance costs.

The Vulcain 301C controller offers unique zoning capabilities that permit the averaging and comparison of multiple sensor readings. Zoning can reduce operational costs by ensuring that localized brief fluctuations registered at a single transmitter do not prematurely or accidentally activate relays.

This reduces runtime on fans, yielding savings in energy consumption and wear-and-tear.

The 301C has the capacity to manage input from three Modbus channels for up to 96 transmitters and up to 50 wireless transmitters that can be associated with 126 zones. Transmitters can belong to an unlimited number of zones, providing maximum operational and control flexibility.

Vulcain 301W wireless gas transmitters detect CO, NO2, and O2, and operates maintenance-free for up to two years without calibration or battery replacement. The 301W can exchange data with the 301C controller over a wireless mesh network via a secure 128-bit encrypted communication protocol. The 301C/301W system is ideal for parking structure monitoring or other zone-based wide area gas monitoring applications.

301EM Refrigerant Gas Monitoring System

• Meets ASHRAE 15, B-52 and International Mechanical

Code requirements

• For optimized gas detection in chiller rooms

• Monitors up to four remote sensors at once

• RS-485 Modbus communications standard

• Three 24 VDC alarm outputs and four 4–20 mA outputs

• Four fully programmable relays, three alarm levels, with built-in visual indicators and audible alarm

ASHRAE and B-52 security standards were established to minimize risk, and protect the safety of mechanical room personnel and the environment at large. The 301EM controller has been designed to meet and exceed these standards. It can be configured to offer manual fan activation plus automatic activation for fan, horn, and strobe.

Latching relay for manual alarm recognition, silence key for manual horn deactivation, built-in 24 VDC outputs for horn operation, and two break-glass switch accessories for manual alarm activation ensure optimal performance.

Toxic, oxygen, and combustible sensors are available, in addition to the refrigerant sensors shown. Call RAECO.

Model Selection Guide

Description

Catalog

Number

VA301C Three­Zone Controller for Gas Detection, Plastic Enclosure

VA301C, RS-485 Modbus Output

VA301C, RS-485 Modbus Output, Datalogging

Accessories

VA301C

VA301C-DLC

Price

$1118.00

2627.00

Relay Output Module, 8 Relays, 5A DPDT

Alarm Annunciator Panel

VA301W Wireless Transmitter, 0-250 ppm CO

VA301W Wireless Transmitter, 0-6 ppm NO2

VA301W Wireless Transmitter, 0-25% O2

VA301R8

VA301AP

301WCO

301WNO2

301WO2

325.00

572.00

895.00

895.00

895.00

CO Replacement Cartridge for VA301W

NO2 Replacement Cartridge for VA301W

O2 Replacement Cartridge for VA301W

S301WCO

S301WNO2

S301WO2

295.00

295.00

295.00

VA301EM ASHRAE­Compliant Controller for Remote Refrigerant Sensing

Outputs: Three 24 VDC, Four Relay, Four 4-20 mA

Outputs: Three 24 VDC, Four Relay, Four 4-20

mA, Strobe Light and Horn

VA301EM

Sensors

R11 Refrigerant Gas Sensor

R22 Refrigerant Gas Sensor

R123 Refrigerant Gas Sensor

R134A Refrigerant Gas Sensor

R404A Refrigerant Gas Sensor

R407C Refrigerant Gas Sensor

R410A Refrigerant Gas Sensor

VA301EM-20

VA301EM-

RFSA-20

VA301IRFSR11

VA301IRFSR22

VA301IRFSR123

VA301IRFSR134A

VA301IRFSR404A

VA301IRFSR407C

VA301IRFSR410A

1288.00

1643.00

1329.00

1329.00

1329.00

1329.00

1329.00

1329.00

1329.00

558

Clockwise from left: Main unit, plug-andplay sensor cartridge, and remote sensor.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

E3Point Toxic and Combustible Gas Monitor

Great for commercial applications

Features

• Comes in stand-alone, stand-alone with remote sensor (dual gas) or network versions

• Connects to analog or digital systems; Compatible with building automation systems, including BACnet, Modbus, or Lonworks

• Advanced electrochemical cells for toxic gases and catalytic bead for combustible gases;

Factory-calibrated plug-and-play sensors and replacement cartridges

• Works through network to improve fault diagnostics and collect data on gas concentration levels, sensor conditions, and more

• Couple with Honeywell 301C controller to log data and daisy-chain up to 96 E3Point units

Honeywell's E3Point is a toxic/combustible gas monitor that makes commercial operations run more intelligently, to protect people, property, and your bottom line. It goes beyond basic protection to increase energy management, efficiency, and economic value.

Smart sensors are pre-calibrated, and auto-configure at setup. They operate continuously on

Honeywell's patented Reflex® technology, which continuously monitors sensor cell condition and alerts you to a fault status. Reflex bounces electrical signals into the E3Point electrochemical sensor cell at regular intervals. It's a form of electronic bump testing for ongoing monitoring of cell response.

E3Point uses demand control ventilation, through relays, BAS, or a controller, to increase energy savings, extend fan life, and align with green building Best Practices. In its network configuration, E3Point can optimize HVAC, fire/smoke, surveillance, and other building systems performance. E3Point on-board relays can be used to activate ventilation fan or strobe light visible alarms.

E3Point network version supports Modbus protocol, so multiple detectors can be daisychained to monitor up to 96 points on a serial bus. The BACnet system can activate alarms, strobes, and horns that are tied to building HVAC controls.

Condensed Specifications

Power Requirements: 24 VAC nominal, 50/60 Hz, 0.4A; 24 VDC nominal (20–38 VDC); With remote sensor: 7W max.; AC input

option: 120 VAC nominal ±10% with on-board transformer

Output: Two DPDT relays, 5A at 250 VAC, 5A @ 30 VDC; 4–20 mA output for communications

Operating Temperature: -40° to 122°F; CO monitoring: -4° to 122°F

Display: Two-line, 8-character backlit LCD with visual indicators;

Green LED for power, two amber LEDs for alarm/fault

Audible Alarm: 85 dBA at 10 feet

Detectable Gases

Gas

Type Range Resolution Alarm A Alarm B Alarm C

CO

H2S

NO2

O2

0–250 ppm 1 ppm 25 ppm 200 ppm 225 ppm

0–50 ppm 0.1 ppm 10 ppm 15 ppm 20 ppm

0–16 ppm 0.1 ppm 0.7 ppm 2 ppm 9 ppm

0–25% vol 0.1% vol 19.5% 22% 22.5%

H2,

Methane,

Propane

0–100%

LEL

Enclosure: Polycarbonate

Approvals: CSA, UL

0.5% LEL 25% LEL 50% LEL 90% LEL

Honeywell Analytics E3Point replaces the retired

Vulcain models VA201T, VA201M, and VA301M.

Model Selection Guide

E3Point monitors no longer come pre-configured with CO sensors. All sensors must be ordered as separate line items.

Description

Single Gas E3Point Toxic/Combustible Gas Monitor

Surface Mount, Analog Output, 24 VAC/VDC Power

Surface Mount, Analog Output, 120 VAC Power

Catalog

Number

E3SA

E3SAH

Price

$324.00

384.00

Duct Mount, Analog Output, 24 VAC/VDC Power E3DA 546.00

Network­Capable Single Gas E3Point Toxic/Combustible Gas Monitor

E3SM*

E3DM*

389.00

546.00

Surface Mount, Modbus Output, 24 VAC/VDC Power

Duct Mount, Modbus Output, 24 VAC/VDC Power

Remote Sensors and Replacement Sensor Cartridges

Remote

Sensors

Carbon Monoxide

Nitrogen Dioxide

Hydrogen Sulfide

Hydrogen

Oxygen

Methane

Propane

Sensor

Cartridges

Carbon Monoxide

Nitrogen Dioxide

Hydrogen Sulfide

Hydrogen

Oxygen

Methane

Propane

* Can also be configured for BACnet.

E3SRMCO

E3SRMNO2

E3SRMH2S

E3SRMH2

E3SRMO2

E3SRMM

E3SRMP

E3SCO

E3NO2

E3H2S

E3H2

E3O2

E3M

E3P

262.00

262.00

262.00

262.00

262.00

262.00

262.00

121.00

221.00

221.00

221.00

221.00

221.00

221.00

FIXED LIquID anD gas anaLyzErs

Products in this catalog are available to rent anywhere in the US. Due to representative agreements with our manufacturer partners, not all products are available for sale in all areas and markets. Prices are current at publication, and are subject to change without notice.

See

Page

gas analyzers

Applied Analytics TLG-837 In-Situ Spectrometer for Tail Gas Analysis

Siemens CALOMAT Extractive Thermal Conductivity Gas Analyzers

Siemens FIDAMAT Flame Ionization Gas Analyzers

Siemens LDS 6 Continuous In-Situ Process Gas Analyzers

Siemens OXYMAT Extractive Oxygen Gas Analyzers

Siemens SITRANS SL Diode Laser In-Situ Oxygen Analyzer

568

560

564

565

562

565

Siemens ULTRAMAT Extractive NDIR Sensor Gas Analyzers

Siemens ULTRAMAT/OXYMAT 6 Combination NDIR/Paramagnetic Analyzer

561

563

GE oxy.IQ Panametrics Oxygen Transmitter 566

GE dew.IQ Moisture Analyzer with IQ.Probe Aluminum Oxide Moisture Probe 567

Liquid analytics

Applied Analytics OMA-300 Process Liquid Analyzer

K-Patents Process Refractometers for Concentration Measurement

Tank Cleaning systems

Gamajet IV GT Rotary Impingement Industrial Tank Cleaning System

Gamajet IX Rotary Impingement Tank Cleaning System for Totes and IBCs

reference Materials

Properties of Common Flammable Gases

Properties of Common Toxic Gases

Refractive Indices of Common Materials

569

176

570

570

491

491

489

559

Looking for instruments for in-line concentration measurement in process liquids? See pages 176 to 179 for K-Patents process refractometers.

Models available for sanitary or general service applications and chemically aggressive liquids.

560

Application Toolkit

Extractive thermal conductivity analyzer for hydrogen gas

Output: 0/2/4–20 mA plus Profibus,

RS-485, and Ethernet

CALOMAT 6, 19" rack mount

Prices start at $6113.00

CALOMAT 6, field mount analyzer

Prices start at $9186.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Extractive Thermal Conductivity Gas Analyzers

CALOMAT 6 Analyzer for Non-Corrosive Gas Mixtures

Features

• Stainless steel tubed and gas-tight sample cell, suitable for H2 and

HE plus flammable gases without purging

• Four measuring ranges, freely programmable and linearized

• Fast response time — T90 < 5 seconds

• Smallest possible measuring spans to 1% Hydrogen

• Galvanically isolated measured value output of 0, 2, or 4-20 mA

• Auto-ranging and remote ranging

• Standard with eight digital I/O

• Interference correction for up to four components

• RS-485 interface standard with optional Profibus DP/PA and Ethernet communications

Specifications

Gas H2 or He in inert mixtures

Range 0–100% vol

Detection limit 1% range

Gas temp.

50°C max.

CALOMAT 6 makes it possible for the measurements of hydrogen and noble gases in non-corrosive gas mixtures. The device is available in 19“ rack-mount housing or in the robust field case for the installation in rough atmospheres. An additional supervision unit makes CALOMAT 6 suitable for installation in Ex-Zone 1.

The CALOMAT's measuring principle is based on the measurement of thermal conductivity, a physical characteristic that differs between gases.

The signal is determined by a bridge that measures electrical resistance and the difference between the measuring gas channel and the reference cell.

Application Toolkit

Extractive thermal conductivity analyzer for corrosive gases

Output: 0/2/4–20 mA plus Profibus,

RS-485, and Ethernet

CALOMAT 62E, 19" rack mount

Prices start at $8353.00

CALOMAT 62F, field mount analyzer

Prices start at $10611.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

CALOMAT 62 Analyzer for Corrosive Gas Mixtures

Features

• Specially designed for applications with corrosive gases

• Integrated correction of cross-interferences, no external calculation required

• For chlorine-alkaline electrolysis, steel mills, liquefied natural gas, ammonia, and fertilizer plants

• Electronics and analyzer unit: Gas-tight separation, purgeable,

IP65 long-life service, even in harsh environments

• Four freely-programmable linear measuring ranges with suppressed zero

• Smallest spans down to 1% H2 (with suppressed zero: 99–100% H2)

• Electrically isolated measured-value output 0/2/4–20 mA

Specifications

Gas H2, NH3 or

CO2 in N2;

SO2 in air, or

CO2 in H2

Range 0–100% vol

Detection limit 1% range

Gas temp.

60°C max.

CALOMAT 62 measures the concentration of gas components — H2,

H2, Cl2, HCl, or HN3 in binary or quasi-binary gas blends. It is specifically designed for use in applications with corrosive gases.

Both CALOMAT analyzers are available in a 19" rack-mount housing or a purgeable rugged IP65 field housing with gas-proofed separation of the electronics and analysis sections. For fast, simple maintenance, the

CALOMAT can communicate over TCP/IP Ethernet with Siemens' SIPROM

GA software. Profibus DP and PA interfaces offer connection to plant automation systems.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

561

Extractive NDIR Gas Analyzers

ULTRAMAT 6 NDIR Two-Beam Alternating Light Analyzer for Hydrocarbons

Application Toolkit

NDIR two-beam analyzer for hydrocarbon gases

Output: 0/2/4–20 mA plus Profibus,

RS-485, and Ethernet

ULTRAMAT 6, field mount

One channel, one IR

Prices start at $12886.00

One channel, two IR

Prices start at $12886.00

ULTRAMAT 6, 19" rack mount

One channel, one IR

Prices start at $11902.00

Two channel, one IR each

Prices start at $17103.00

One channel, two IR

Prices start at $11872.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

Features

• Highly selective with double-layer detector and optical coupler for reliable measurement even in complex gas mixtures

• Corrosion-resistant materials in gas path

• For boiler control in combustion plants, emissions measurement in incineration plants, process gas concentrations in chemical applications, environmental protection, MAC-value workplace monitoring and warning equipment

• Ex versions to analyzer flammable and non-flammable gases or vapors in hazardous areas

• Supports one analog output and six relay outputs, two analog inputs and six binary inputs

• RS-485 interface standard with optional Profibus DP/PA

ULTRAMAT 6 single-channel or dual-channel gas analyzers operate according to the NDIR two-beam alternating light principle, and measure highly selective gases with absorption bands in the infrared wavelength range from 2 to 9 mm. Single-channel analyzers measure up to two gas components. Dual-channel analyzers measure up to four gases simultaneously.

The gas proof separation of the electronic and physical components of the field-mount analyzer with IP65 protection and purging gas connection guarantees a long service life, even in severe ambient conditions.

Specifications

Gas IR wavelength

2-9

mm: CO,

CO2, NO, SO2,

NH3, H2O, CH4, hydrocarbons

Range

Detection limit

Depends on gas

Gas specific from

0.05 ppm

Gas temp. 50°C max.

ULTRAMAT 23 Low-Cost NDIR Analyzer for Hydrocarbons and Oxygen

Application Toolkit

NDIR two-beam analyzer for hydrocarbon gases

Output: 0/2/4–20 mA plus Profibus,

RS-485, and Ethernet

ULTRAMAT 23, 19" rack mount

One IR gas plus O2

Prices start at $6671.00

Two IR gases plus O2

Prices start at $9560.00

Three IR gases plus O2

Prices start at $12119.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

Features

• Versions for one, two, or three infrared-sensitive gases plus O2

• Infrared sensors plus electrochemical measuring cell

• Highly selective by multiple layer detectors

• AUTOCAL in process with ambient air — high efficiency, so no calibration gas or accessories are required

• Supports one analog output and six relay outputs, two analog inputs and six binary inputs

• RS-485 interface standard with optional Profibus DP/PA

ULTRAMAT 23's multi-component design with NDIR sensors for IRactive gases and an electrochemical cell for oxygen measurement make it an economical and space-saving device for accurate gas measurement. The integrated automatic calibration function using ambient air reduces the need to check with calibration gases to just once per year.

Multi-layer detectors guarantee high selectivity and reduced water vapor interference. The measuring cells used are robust and resistant, and can be cleaned in the event of pollution. ULTRAMAT 23 also supports two freely configurable undershoot and overshoot limit values per measured gas.

Specifications

Gas IR wavelength 2-9

mm: CO, CO2, NO,

SO2, CH4, plus

O2 (via electrochemical cell)

Range Depends on gas, analyzer model

Gas temp. 50°C max.

562

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Extractive Oxygen Gas Analyzers

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

OXYMAT 61 Paramagnetic Analyzer for Oxygen in Standard Applications

Application Toolkit

Paramagnetic alternating pressure analyzer for oxygen gas

Output: 0/2/4–20 mA plus Profibus,

RS-485, and Ethernet

OXYMAT 61, 19" rack mount

Prices start at $5200.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

Features

• Single channel oxygen analyzer in 19" rack mount enclosure

• Fast response — T90 <3 seconds

• Versions with internal pump for reference gas air or external reference gas supply

• Stainless steel sample cell and Viton tubing

• Autocal and autoranging

• Standard with eight digital I/O

• RS-485 interface standard with optional Profibus DP/PA and Ethernet communications

OXYMAT 61 is a low-cost oxygen analyzer for standard applications. It requires ambient air — supplied by an integral pump or compressed bottled gas — as its reference gas.

Specifications

Gas

Range

O2

0–100% vol

Detection limit 2% range

(200 ppm)

Gas temp.

50°C max.

OXYMAT 6 Paramagnetic Analyzer for Oxygen in Corrosive Gases

Application Toolkit

Paramagnetic alternating pressure analyzer for oxygen gas

Features

• Single channel oxygen analyzer

• Paramagnetic alternating pressure principle for small measuring ranges (0–0.5% or 99.5–100% oxygen) with absolute linearity

• Detector element has no contact with sample gas — provides long service life under harsh conditions

• Available in 19" rack mount or field mount unit (left) for ATEXapproved Zone 1 and Zone 2 locations

• Standard with eight digital I/O

• For boiler control in firing systems, applications in safety-relevant, areas, warning equipment, environmental protection, inert gas monitoring as certified gas warning equipment, or to analyze flammable and non-flammable gases or vapors in hazardous areas

• RS-485 interface standard with optional Profibus DP/PA and Ethernet communications

Specifications

Gas

Range

O2

0–100% vol

Detection limit 0.5% range

Gas temp.

50°C max.

Output: 0/2/4–20 mA plus Profibus,

RS-485, and Ethernet

OXYMAT 6, 19" rack mount

Prices start at $8436.00

OXYMAT 6, field mount analyzer

Prices start at $11031.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

Most frequently used for demanding applications, the OXYMAT 6 must meet high standards with regards to reliability and measuring quality.

OXYMAT 6 measures oxygen using the paramagnetic alternating pressure method, which guarantees perfect linearity, and allows parameterization of small measuring ranges of 0–0.5% (detection limit 50 ppm) up to 0–100% in a single device. The sensor inside the detector does not come into contact with the sample gas, making the OXYMAT suitable for measuring corrosive gases. Corrosive-resistant materials are used in the gas path.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

563

OXYMAT 64 Zirconium Dioxide Probe Analyzer for Trace Oxygen Detection

Application Toolkit

Zirconium dioxide probe analyzer for trace oxygen gas

Features

• Single channel oxygen analyzer in 19" rack mount enclosure

• For ppm levels of oxygen concentrations in pure gas applications

• Versions with internal pump for reference gas air or external reference gas supply

• Supports one analog output and six relay outputs, two analog inputs and six binary inputs

• RS-485 interface standard with optional Profibus DP/PA

Specifications

Gas

Range

O2

0–10 to 0–99999 vpm

Detection limit

1% span, <0.1 vpm within 0–10 vpm range

Gas temp. 50°C max.

Output: 0/2/4–20 mA plus Profibus,

RS-485, and Ethernet

OXYMAT 64, 19" rack mount

Prices start at $8247.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

OXYMAT 64 can control the measurement of oxygen concentration in the smallest tracks, even down to the smallest measuring area of 0–10 ppm.

OXYMAT 64 is ideal for production of technical gases, welding, air separation plants, metal production, hardening shops, chemical plants, and food and beverage applications.

OXYMAT 64 works with ZrO2 sensors, which measures gas with steady flow through a 650°C heated, pipe-shaped sensor. While the sample gas flows through the sensor, the outside of the sensor is exposed to ambient air, which acts as a reference electrode. Depending on the application, both catalytic active and inactive ZrO2 sensors are available.

ULTRAMAT/OXYMAT 6 Combination NDIR and Paramagnetic Analyzer

Application Toolkit

Combination analyzer for hydrocarbons and oxygen

Output: 0/2/4–20 mA plus Profibus,

RS-485, and Ethernet

ULTRAMAT/OXYMAT6, 19" rack mount, Two channels: 1xO2, 1xIR

Prices start at $16718.00

ULTRAMAT/OXYMAT6, 19" rack mount, Two channels: 1xO2, 2xIR

Prices start at $16718.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

Features

• Oxygen and infrared-active gas measurement in a single 19" rack mount enclosure

• Corrosion-resistant materials in the gas path for measuring highly corrosive sample gases

• Cleanable sample cells for cost savings

Gas

Specifications

Range

O2, CO, CO2,

NO, SO2, NH3,

H2O, CH4, hydrocarbons

0–100% volume

• ULTRAMAT channel supports low detection limits and reliable measurement in complex gas mixtures

• OXYMAT channel suitable for purity monitoring and air separation

• Supports one analog output and six relay outputs, two analog inputs and six binary inputs

• RS-485 interface standard with optional Profibus DP/PA

The ULTRAMAT/OXYMAT 6 analyzer combines the features of the

ULTRAMAT 6 NDIR sensor analyzer and the OXYMAT 6 paramagnetic analyzer, for two infrared channels and one oxygen measurement channel in a single housing and minimal amount of space.

The IR physics of the ULTRAMAT use the NDIR method to continuously and selectively measure one or more infrared-active gases, with absorption bands in the infrared wave range from 2 to 9 micrometers. The use of optical couplers and optical filters increase the selectivity, so the analyzer can be used for measurements even in complex gas mixtures, at low concentrations and low detection limits.

The OXYMAT physics use the paramagnetic property of the oxygen molecule to measure very precise concentrations of oxygen. This technology guarantees perfect linearity, and allows parameterization of minimal measuring ranges of 0–0.5% (detection limit 50 ppm) up to 0–100%, or even

99.5–100% in a single device.

Detection limit

0–5 ppm, 0–100 ppm, 0–0.5% O2

(gas-dependent)

Gas temp. 50°C max.

564

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Extractive Flame Ionization Gas Analyzers

FIDAMAT 6 Flame Ionization Detector for Extractive Gas Analysis

Application Toolkit

Extractive flame ionization detector for total hydrocarbons, 19" rack mount analyzer

Output: 0/2/4–20 mA plus Profibus,

RS-485, Ethernet optional

FIDAMAT 6 analyzer

Prices start at $10225.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

Features

• Four freely parameterizable linear measuring ranges with suppressed zero

• Galvanically isolated measured value output of 0, 2, or 4-20 mA

• Complete heated gas path up to 200°C for measuring corrosive gases and those with moisture content up to 100%

• Wear-free, corrosion-proof stainless steel filter

• Clog-free sample gas quartz capillary

• Corrosion protection by pump shutdown in case of a deviation in setpoint temperature of oven or pump heating system

• Response factors according to emission requirements

• Low combustion air consumption

• Low cross-sensitivity to interfering gases

• Low influence of oxygen on measured value

FIDAMAT 6 flame ionization gas analyzers measure total hydrocarbons in gases from traces to high percentage measuring ranges. Typical applications include emissions monitoring for government regulation and compliance, exhaust monitoring from driers and paint shops, process measurement in the chemical and petrochemical industries, TLV measurement in workplaces, ambient air monitoring and measurement of impurities in gas production.

Thanks to its robust design, FIDAMAT is equally suited for measuring both total trace hydrocarbons and corrosive process gases.

The heart of the FIDAMAT is the flame ionization detector. The sample gas is mixed with hydrogen and a certain amount of air, and fed to nozzle in the combustion chamber. There, the mixture is ignited and the hydrocarbons are ionized. An electrode on top of the flame picks up the ions. The ionization current is directly proportional to the amount of hydrocarbon atoms in the sample gas.

FIDAMAT 6 features Siemens' backlit LCD analyzer display, with simultaneous display of measured value, status bar, and measuring ranges. It includes warning and fault messages for failure of combustion gas, extinguished flame, and to indicate pump and filter faults.

A standard RS-485 communication connection supports USB,

Ethernet, and RS-232, and can be used to connect to Profibus DP/PA interface.

The system includes one analog output for each measured component, two programmable analog inputs, six configurable binary inputs, six configurable relay outputs for failure, maintenance request, maintenance switch, limit alarm, external solenoid valves, and measuring point switchover. Eight more binary inputs and eight relay outputs can be added for autocalibration to up to four calibration gases.

FIDAMAT operation includes automatic startup and shutdown by flow control, automatic zero and span calibration, automatic flame reignition, and safety shutoff of sample gases and back-purge of the gas path.

Specifications

Gas

Range

Resolution

Total hydrocarbons

0-99.999 vpm

0.1% value

Detection limit 50/100 ppb

Gas temp.

200°C max.

Substance

Acetone

Acetylene

Benzene

Chlorobenzene

Chloroform

Cyclohexane

Dichloromethane

Ethane

Ethanoic acid

Ethanol

Ethyl acetate

Ethyl benzene

Isobutyl acetate

Iso-octane

Isopropanol

Methane

Methanol

Methyl acetate n-Butane n-Heptane n-Hexane n-Propane

Propene

P-Xylene

Tetrachlorethene

Toluene

Trichloroethene

1.06

0.87

0.67

1.00

1.00

1.01

1.00

0.84

1.03

1.07

1.06

1.01

0.99

1.13

0.83

0.76

0.96

0.83

1.04

0.81

Mean

Response

Factor

0.92

0.91

1.01

1.15

0.72

1.08

1.13

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

565

Continuous In-Situ Process Gas Analyzers

Application Toolkit

In-situ tunable diode laser system for multigas measurement, rack-mount analyzer with field-mount sensors.

I/O (per-channel): Two analog outputs three binary inputs and outputs.

Ethernet communications.

LDS 19" rack-mount analyzer

Prices start at $15750.00

LDS cross duct-mount sensors

Prices start at $4815.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

LDS 6 In-Situ Multipoint Process Gas Analyzer

Features

Specifications

• In-situ measurement — no gas sampling required

• Rack-mount analyzer supports up to three measuring points

• Built-in auto-calibration, dynamic dust load compensation (up to

100 g/Nm3)

• High selectivity, no cross interferences

Gas

(three max)

Measuring range

O2, NH3, HF, H2O,

CO2, CO, HCl

0–5 ppm to 0–5%

(gas-specific)

Detection limit From 0.1 ppm

• Fast determination of gas concentration and temperature at the same time — no temperature influence from radiation of particles, no wall effect, no drift

Gas temp.

1500°C max.

Response time 1-3 seconds

• For applications in process control, DeNOx optimization, combustion control, emissions monitoring, filter optimization

LDS 6 is a high-performance process gas analyzer that operates directly in the process stream. No extractive sampling lines needed. The central unit is separated from the sensor using fiber optics. So, no matter how hostile the process environment, the analyzer can be installed outside the hazardous area.

The biggest benefit of in-situ gas analysis is that measurements are carried out in real time, so you have more proactive control of dynamic processes and can make cost-saving corrections quickly.

The very nature of laser light allows single-line spectroscopy free of interferences. Since the bandwidth of the laser light is extraordinarily small, only the gas component of interest will interact.

Other influences, like dust and temperature, are eliminated by the inherent compensation capabilities of this measurement technology.

LDS 6 comes with all the features for easy-to-use and service-friendly operation. The compact analyzer unit installs easily into a standard 19" rack. A built-in calibration system allows a permanent hands-off self-calibration of the instrument. This, together with the intuitive user interface, makes it very easy to operate the LDS 6 with minimal training. In the unlikely case of service need, the modular design of the system allows for easy replacement of all components in the field, even the laser module.

Application Toolkit

In-situ tunable diode laser system for oxygen measurement

0-100% O2, 0.02%V resolution

Two each: Analog inputs, analog outputs, binary inputs, and binary outputs, Profibus DP optional.

SITRANS SL

Prices start at $17700.00

Please issue all orders to Siemens

Industry Inc, c/o RAECO.

SITRANS SL Diode Laser In-Situ Oxygen Analyzer

Features

• In-situ measurement — no gas sampling required

• In-line reference cell — stable instrument operation with outstanding performance

• Low maintenance — easy to align and service

• Almost no cross interferences

Specifications

Gas

Measuring range

Oxygen

0–100% (lower ranges selectable

Resolution 0.02% volume

Detection limit 200 ppm

Siemens SITRANS SL is a diode laser gas analyzer suitable for fast and non-contact measurement of gas concentrations in process

Gas temp.

600°C max.

Response time 1-3 seconds

or flue gases. The paired sensors (transmitter and receiver) are meant to be mounted directly on the process with no need of sampling systems. All hardware necessary for processing the measurement signal into a concentration value, monitoring, control and communications are integrated into these two main modules. The IP65-rated sensors are designed for operation under harsh environmental conditions.

Laser light is sent from the transmitter, passing through the process gas, arriving at the detector on the receiver side. The measurements are performed on-line with a very short response time. The laser characteristics allow single-line spectroscopy free of interferences. Since the laser light's bandwidth is extremely narrow, only the gas component of interest will interact with it.

Other process influences, like dust and temperature, are eliminated due to the inherent compensation capabilities of this technique. An in-line reference cell filled with a non-interfering reference gas minimizes the need for maintenance and recalibration.

566

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

oxy.IQ Panametrics Digital Oxygen Transmitter

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Features

• Two-wire, loop powered 4-20 mA transmitter

• Proven galvanic fuel cell O2 sensor technology

• User selectable ranges from 0–10 ppm to 0–10000 ppm or 0–1% to 0–50% oxygen

• Display shows measured value, sensor lifetime indication, NAMUR error indication

• Front keypad for selectable and programmable ranges

• Sensor failure output error

The oxy.IQ is a highly reliable and cost-effective two-wire loop-powered transmitter with a linearized 4-20 mA output. It measures oxygen in ten different selectable ppm ranges and seven selectable percentage ranges, using proven sensor technology to accurately measure oxygen in a variety of gases. When equipped with optional zener barriers, the oxy.IQ can be mounted in hazardous (classified) locations.

The oxy.IQ's oxygen sensor is an advanced galvanic fuel cell that provides superior performance, accuracy, stability, and long life. Its innovative design eliminates the potential for negative signal output and reduces the sources of contamination. The cell is unaffected by other background gases or hydrocarbons, and is compatible with acid gases

(OX-2 and OX-4 cells). Because the cell is self-contained, it requires minimal maintenance.

There's no electrolyte to change or electrodes to clean.

Oxygen Sensor Interference Gases

Applications

• Glove box purge and leak detection

• Natural gas

• Semiconductor wafer machines

• Coating process machines

• Membrane air separators

• Inert wending gases

• Pure gaseous hydrocarbon streams

• Process monitoring of gaseous monomers

• Heat treating and bright annealing

Gas

H

2

S

SO

3

SO

2

HCl, HCN

OX-1, OX-5 ppm Cont

<5 ppm

<10 ppm

<10 ppm

<1000 ppm

OX-2 ppm

Cont

<10 ppm

<10 ppm

[3]

[3]

Cont

0.0005%

0.01%

0.01%

0.1%

OX-3 %

Int [1]

0.01%

0.1%

0.1%

1.0%

Cont

0.001%

0.01%

[3]

[3]

OX-4 %

Int

0.1%

0.1%

[3]

[3]

CO

2

<1000 ppm

NO

2

, CL

2

[2]

Cont = Continuous, Int = Intermittent

[3]

[2]

0.1%

[2]

20%

[2]

[3]

[2]

[3]

[2]

[1] Recommended maximum exposure 30 minutes followed by flushing with ambient air for equal period

[2] Minimal effect on sensor performance, but produces signal interference of 1:2 ratio, ppm levels only (e.g.,

100 ppm NO

2

looks like 200 ppm O

2

)

[3] Minimal effect on sensor performance.

Condensed Specifications

User-Selectable Measurement Ranges: PPM Sensors: 0–100,

0–200, 0–500, 0–1000, 0–2000, 0–5000 or 0–10000 ppm v

O

2

;

OX-1 or OX-2 PPM Sensors: 0–10, 0–20 or 0–50 ppm v

O

2

; Percent

Sensors: 0–1%, 0–2%, 0–5%, 0–10%, 0–25%, or 0–50% O

2

Sample Flow Rate: 1.0 SCFH (500 cc/min) recommended

Construction: NEMA 4X/IP66 weatherproof, corrosion-resistant enclosure; Wetted Materials: 316 stainless steel,Viton o-ring, gold-plated sensor electrical contacts and glass; Process

Connection: 1/8" NPT inlet and outlet; Cable: PN 704-1317: Black jacket, twisted pair with connector; 26 AWG, 2m or 10m length

Approvals (Pending): General purpose: Non-incendive without use of zener barrier or galvanic isolator, US/Canada Class I, Div 2,

Groups A–D, T6; Intrinsically safe: With zener barrier, USA/Canada

Class I, II, III, Div 1, Groups A–G, T6, AEx ia IIC T6; Ex ia IIC T6; Tamb

-20° to 60°C

Installation: Non-Incendive (Div 2) and General Purpose: No zener barrier required, 9–28 VDC loop powered, 0.7 W max. Intrinsically

Safe: Requires MTL7706 zener barrier, onle IS cable, one non-IS cable, 24–28 VDC @ 50 mA power required

Operating Temperature: O2 Sensor: 32° to 113° F (0° to 45°C)

Accuracy at Calibration Point: ±1% range standard; OX-1/OX-2

0–10 ppmv: ±2% range

Model Selection Guide

Description

oxy.IQ Oxygen transmitter, 4–20 mA output

Sensor None

Standard PPM (0–10 to 0–1000 ppm)

Acid ppm (0–10 to 0–1000 ppm)

Standard Percent Sensor

Acid Percent Sensor

Standard PPM (0-100/200/500/1000)

Package General Service

Intrinsically Safe

Cable None

2 Meter Cable

10 Meter Cable

Barrier None

Intrinsically Safe Zener Barrier

Catalog Price

OXYIQ- $1900.00

0 _ _-

1 _ _-

2 _ _-

3 _ _-

4 _ _-

5 _ _-

_ 1 _-

_ 2 _-

0.00

360.00

290.00

205.00

275.00

245.00

0.00

Call

_ _ 0-

_ _ 1-

_ _ 2-

0

1

0.00

0.00

100.00

0.00

Call

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

567

dew.IQ Single Channel Moisture Analyzer with IQ.Probe

Applications

• Industrial gas

• Furnace gas/heat treating

• Power generation

• Air dryer

• Pharmaceutical

• Aerospace

Easy field upgrade for the Panametrics

MMS35, System 580, Model 600, 700 and older analyzer units.

Features

• Rack, bench, panel, and wall mount configurations

• NEMA 4 weatherproof membrane front display and keypad

• Compatible with M series or IQ.probe moisture probes

• Displays moisture content in dew/frost point and ppmv

• Fail-safe fault alarm relay

• Two measurement alarm relays

The dew.IQ is an economical single-channel aluminum oxide hygrometer, ideal for industrial applications that require accurate, real-time moisture measurement.

Installing the dew.IQ is simple. As a field upgrade for its predecessors, the M series probe and cable mate to the dew.IQ in minutes, minimizing installation costs.

The dew.IQ accurately tracks fast-changing process conditions and displays the moisture content on an LCD as dew/frost point temperature in °F or °C or as ppm two Form C alarm relays for high and low moisture limits. v

with a constant pressure input. Measurement is also available as an analog output. The dew.IQ features

The large display and six-button keypad combine to make selection of analog output zero and span, alarm setpoints fast and easy, and entering calibration data simple and straightforward.

Aluminum Oxide Moisture Probes

Both the IQ.probe and the M series moisture probes are rugged and accurate true absolute humidity sensors, with calibration traceable to national standards.

The IQ.probe measures moisture concentration in gases from trace to ambient levels.

It requires only twisted pair cabling, so it can be mounted up to 3000 feet away from the analyzer. The real power of the IQ.probe comes from an electronics module that's attached to the sensor probe. The 16-bit resolution lets it detect parts per billion changes in moisture concentration. The electronics are self-calibrating, ensuring long-term stability.

The IQ.probe sensor can withstand process temperature excursions up to 158° F and process pressures from vacuum to 5000 PSIG. No minimum flow rate is required. It works with gas flow ranges from static to 10,000 cm/s linear velocity at 1 atm, and liquid flow ranges from static to 10 cm/s linear velocity at a density of 1 g/cc.

Specifications

Input: Moisture signal from an M series or IQ.probe thin film aluminum oxide sensor

Calibrated Accuracy (at 77°F): ±3.6° F from -85° to 50°F, ±5.4° F from -112° to 87° F

Dew/Frost Point Temperature: Overall range capability: -166° to 140°F; Standard: -112° to

68°F with data to -166° F; Ultra-low: -166° to -58° F; High range data: -112° to 140°F

Analog Output: Single recorder output, internally optically isolated, 10-bit, 0.1% resolution

Alarm Relays: One failsafe fault relay, two standard Form C SPDT relays, rated 3A @ 250

VAC/30 VDC; Set to any level within the range of the instrument, programmable from the front panel

Datalogger: 32 GB capacity with MicroSD card, 2 GB card included with unit

Display Functions: Dewpoint temperature in °F, °C, or ppmv with a constant pressure input; sensor signals for diagnostics

Power Requirements: Universal power, 100–240 VAC @ 50/60 Hz, or 24 VDC nominal

Operating Temperature: -4° to 140°F (-20° to 60°C)

Intrinsic Safety: External safety barrier for moisture input, optional on M series probe

568

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

TLG-837 Tail Gas/Air Demand Analyzer

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Features

• Continuously measures concentrations of H2S and SO2 and outputs air demand signal

• Designed for safety — keeping the sample media in the process pipe, so it doesn't corrupt the electronics

• Patented Demister sampling probe with internal sulfur vapor removal

• Totally solid state with no moving parts, sample lines or heat tracing — designed for low maintenance

• Ultra-safe fiber optic design — no toxic or explosive sample gas in analyzer enclosure

• Superior off-ratio range (100:1 <H2S/SO2 ratio <1:20)

• Internal pressure and temperature compensation

• Simple hot-tapping capability

• Convenient introduction method for verification gases

• Automated steam wash cycle for optics

The TLG-837 Analyzer

The TLG-837 analyzer uses a high resolution UV-VIS spectrophotometer to acquire a 200-800 nm absorbance spectrum of the sample gas. Within this spectrum, the analyzer can identify the distinct absorbance curves of each analyte, measure the height of these curves, and correlate the value directly to real-time concentration.

Unlike conventional multi-wave photometers, the TLG-837 uses a dispersive spectrophotometer to acquire a full highresolution spectrum. Each integer wavelength in the spectral range is individually measured by a dedicated photodiode.

The HMI controlling the spectrophotometer and communication provides a simple touchscreen interface.

Running Applied Analytics' ECLIPSE software, the HMI lets you quickly and easily perform tasks like auto zero scheduling, alarm configuration, analog output configuration, and more.

The TLG-837 Demister Sampling Probe

Mounted directly on the process pipeline, the in situ demister probe draws a continuous sample for analysis.

The patented design is extremely effective at condensing elemental sulfur vapor out of the sample in a controlled manner in order to protect measurement integrity.

Usually present in the form of S8, sulfur vapor will jeopardize analysis by distorting absorbance readings or condensing to solid sulfur and coating the optical windows. Other analyzers use crude, confusing correction procedures, often relying on temperature-based sulfur prediction. The only way to secure true measurement accuracy is to physically keep the sulfur from reaching the flow cell.

Using steam, the TLG-837 maintains a stable temperature along its body that forces incident sulfur to liquefy and drip back into the process. This elegant design exploits the relatively high boiling point of elemental sulfur to ensure that the sample reaching the flow cell is nearly sulfur-free.

Call RAECO for help specifying the right tail gas analyzer configuration for your process.

Condensed Specifications

Measurement Principle: Dispersive UV-Vis absorbance spectrophotometry

Detector: nova-II™ UV-VIS diode array spectrometer

Spectral Range: 200-800 nm

Light Source: Pulsed xenon lamp, average 5 year lifespan

Sample Interface: TLG-837 in situ sampling probe

Range/Accuracy: Hydrogen Sulfide (H2S)/Sulfur Dioxide (SO2): 0-2% range: ±1% measurement @ ±0.4% repeatability; Carbonyl Sulfide

(COS)/Carbon Disulfide (CS2): 0-2,000 ppm range: ±1% measurement

(±5% under 500 ppm) @ ±0.4% repeatability; Air Demand: ±1% measurement @ ±0.1% repeatability

Sensitivity: ±0.1 % full scale

Response Time (T

10

- T

90

): 10s

Wetted Materials: 316/316L Stainless steel

Outputs: One 4-20mA output per component; four digital outputs for fault and sampling system control; Options: Modbus TCP/IP, RS-232

Area Classification: Class I, Div. 2 standard; Class I, Div. 1 and ATEX

Exp II 2(2) GD optional

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

569

OMA-300 Process Chemical Analyzer

Features

• Measure up to five chemical concentrations and physical properties simultaneously with a single OMA

• Totally solid state — no moving parts, lower maintenance

• Ultra-safe fiber-optic design with dedicated sample flow cell

— no sample fluid enters the analyzer enclosure

• Add or remove analytes at any time

• Subtracts background absorbance to help avoid false positives

The OMA-300 industrial liquid analyzer measures a highresolution absorbance spectrum in a continuously drawn sample from a liquid or gas process stream to provide real-time analytics, including chemical concentrations, purity, and color.

The OMA measures UV-Vis/SW-NIR (ultraviolet-visible / short wave near infrared) absorbance. Depending on which range best suits the analytes, the OMA is configured to acquire either a

200-800 nm spectrum (using xenon light source) or 400-1100 nm spectrum (using deuterium light source).

The OMA process analyzer is available in three different models: a wall-mount version, a rack-mount model, and a portable analyzer in a rugged suitcase. It is also available with a NEMA 4X cast aluminum X/Y purged enclosure for explosion-proof ratings.

Some chemicals — carbon dioxide, carbon monoxide, ethylene, methane, and water — cannot be measured in the OMA’s spectral range. These measurements can easily be implemented using

MicroSpec modules that integrate seamlessly into the OMA.

No chemicals in the analyzer — How it works

1 The white light signal originates in the pulsed Xenon lamp.

2 The signal travels via fiber optic cable to the flow cell. A collimator narrows the light beam.

3 The signal travels directly across the flow cell, interacting with the continuously drawn process sample.

4 The signal exits the flow cell through a collimator and travels via fiber optic cable to the spectrophotometer.

5 The signal is dispersed by the holographic grating. Each differentiated wavelength is focused onto a designated photodiode within the diode array.

6 The absorbance spectrum is measured by plotting the lost light intensity at each wavelength.

Condensed Specifications

Sample Phase: Gas or liquid

Measurement Principle: Dispersive ultravoilet visible (UV-Vis) and short wave near infrared (SW-NIR) absorbance spectrophotometry

Detector: nova II™ diode array spectrophotometer

Spectral Range: 200-800 nm or 400-1100 nm

Light Source: Pulsed xenon lamp (average 5 year lifespan)

Signal Transmission Standard: 600 μm core 6' fiber optic cable

Sample Introduction Standard: Stainless steel 316L flow cell with application-dependent path length

Repeatability: ±0.5% of scale

Photometric Accuracy: ±0.004 AU

Spectral Resolution: Average 1 nm

Sample Temperature: Immersion probe or standard flow cell: -4° to 302° F; Optional sample cooling: Up to 1832° F

Sample Pressure: Immersion probe: 1470 psig max.; Standard flow cell: 3000 psi max.

Ambient Temperature: Standard: 32° to 95 °F; With optional

temperature control: -4° to 131 °F; To avoid radiational heating, use a sunshade for systems installed in direct sunlight.

Outputs/Communication: One galvanically isolated 4-20mA analog output per measured analyte (up to 3; available by upgrade); Two digital outputs for fault and SCS control; Optional: Modbus TCP/

IP; RS-232; RS-485; Fieldbus; Profibus; HART

Data Storage: 32GB Solid State Drive

Approvals: CSA Class I, Div 1; CSA Class I, Div 2; ATEX Exp II 2(2) GD

Call RAECO for help specifying the right liquid analyzer configuration for your process.

570

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Rotary Impingement Tank Cleaning Systems

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Gamajet IV GT Automated Tank Cleaning System for Large Tanks

Features

• For tanks with diameters of more than 15 feet

• Up to 100 pounds of cleaning force

• Cleans up to a 100 ft radius

• Heavy-duty, durable design

• Streamlined turbine and internal flow passages

• Flo-thru and directional options

The Gamajet IV GT tank cleaning machine is a hydraulically driven rotary tank cleaning machine that revolves 360° in both horizontal and vertical planes. Synchronized solid jets provide a tight, thorough scouring pattern covering all interior tank surfaces in one cycle.

It is available in stainless steel or silicon bronze with a choice of oil-lubricated or flow-thru (wash fluid lubricated) gearboxes. Gear trains are designed to maximize wear life for improved reliability.

With a choice of twelve nozzle sizes, hydraulic turbines and stators along with two gear systems, the Gamajet IV GT offers a wide operating range of flow rates, nozzle rotation speeds, and wash cycles. The IV GT”is fully capable of high concentration chemical recirculation cleaning or high pressure/low volume water jet scrubbing in fixed CIP automated systems.

Condensed Specifications

Operating Range: Pressure: 20 to 500 psi standard; 20 to >700 psi high pressure model; Temperature: -60° to 250°F

Flow Rate: 30–320 GPM (114 to 1211 l/min)

Cleaning Radius: 100’

Wash Cycle Time: 3 to 30 Minutes

Nozzle Rotation Speed: 2 to 20 rpm

Impact: 85 lbs at 25’

Dimensions: 12.2” tall x 4.2” diam., 6.1” wide; Clearance: 12.7” for dual pin drive,

11.5” for triple pin drive

Castings: 316 stainless steel

Dual Inlet Connection: 2” NPT female and

2 1/2” quick disconnect male

Rotor/Gearbox Shafts: Hardened stainless steel, plasma-sprayed ceramic coating, polished carbide thrust washer

Bearings: Tungsten carbide. PTFE Oilite bronze bearings in flo-thru gearboxes

O-Rings: Viton standard

Drive Gears: Stainless steel alloys; long-life tungsten carbide thrust washers

Lubrication: Gearbox: FDA approved oil;

Flo-thru: Lubricated by the cleaning solution; Waterside: Controlled amount of cleaning solution flows through the tee and nozzle housing bearings for lubrication and cooling.

Self-Cleaning Provisions: Low-pressure bypass keeps bevel gears and other internal parts flushed free of debris

Nozzles: Twelve sizes from 0.177" to 5/8”

(4.5 to 15.9mm). Nozzle sizes of 1/4” (6.35 mm) and smaller come with tungsten carbide inserts

Call RAECO for help designing the right tank cleaning system for your process vessels.

Gamajet IV GT Cost-Effective Tank Cleaning for Small Tanks and Totes

Features

• Cleans small and mid-sized totes and other vessels in under 4-12 minutes

• 12 lbs of cleaning force at 10’

• Compact, durable and easy to maintain

• Capable of removing latex paint from a polyurethane tote

A quantum leap in tank cleaner durability, efficiency, and price, the Gamajet

IX offers compact cleaning for small and mid-sized tanks with fewer parts, and a highly durable design, for superior performance at an affordable price, making it the ultimate tote washer. Fewer parts means fewer breakdowns and lower maintenance costs.

Originally designed for tote cleaning applications, the Gamajet IX is also perfect for other small and mid-sized tank cleaning applications. Its 360° spray pattern provides thorough scouring of the entire tank or tote, reducing operating time and costs.

Condensed Specifications

Operating Range: Pressure: 50 to >1000 PSI; Temperature:

32° to 250° F

Flow Rate: 4 to >30 GPM (15.14 to 113.56 l/min)

Cleaning Radius: 7.5’

Wash Cycle Time: 4-15 Minutes

Impact: 12 lbs at 10’

Dimensions: 8.75” tall x 1.80” diam., 2.76” min. I.D. clearance

Construction: Machined from 316L Stainless Steel investment castings or bar stock

Impeller and Final Shafts: Plasma-sprayed with a

Chromium Oxide coating on Stainless Steel

Inlet Connection: 3/4” NPT; 1-1/4” Camlock; Tri-clover option

Seals: Static: Viton; Kalrez and EPDM optional; Dynamic: PTFE, spring-loaded, double-lipped. Carbon fiber reinforced

Nozzles: Dual or quad 0.050” to 0.225” orifice diameters standard. Other nozzle sizes available upon request.

Options: Quad nozzles for faster cleaning; Modified version to work with a pressure washer

FLOW

Products in this catalog are available to rent anywhere in the US. Due to representative agreements with our manufacturer partners, not all products are available for sale in all areas and markets. Prices are current at publication, and are subject to change without notice.

See

Page

Portable Ultrasonic Flowmeters

GE TransPort PT878 Liquid Ultrasonic Flowmeter 572

Fixed Ultrasonic Flowmeters

GE AquaTrans AT868 Dual Channel Liquid Ultrasonic Flow Transmitter

GE AquaTrans AT600 Single Channel Liquid Ultrasonic Flow Transmitter

GE DigitalFlow DF868 Liquid Ultrasonic Energy Meter

GE DigitalFlow GF868 Flare Gas Mass Ultrasonic Flowmeter

GE DigitalFlow GS868 Ultrasonic Steam Mass Flowmeter

GE PanaFlow HT Ultrasonic SIL Liquid Flowmeter

GE PanaFlow Z3 Three-Path Ultrasonic Flowmeter for Liquids

574

575

576

578

579

578

573

571

RAECO is proud to be your exclusive representative for GE Measurement and

Control flowmeter and analytics instrumentation in the Midwest US.

Visit www.RAECO.com for more details, or call RAECO at 800-852-9795.

572

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

TransPort PT878 Portable Liquid Ultrasonic Flowmeter

Features

• Small, light weight, and easy to use

• Suitable for most pipe sizes and materials, including lined pipe

• Non-intrusive flow measurement

• Velocity, volumetric, and energy flow rates

• Totalized flow and trend data

• Large backlit LCD display with alphanumeric and graphic formats

• Logs more than 100,000 flow data points

• Rechargeable battery pack

• IP67-rated submersible package

• Options include thickness gauge and energy measurement

Applications

• Potable water, wastewater, cooling and heating water

• Ultrapure water and liquids

• Water/glycol solutions

• Crude oil, diesel and fuel oils, lubricating oils

• Refined hydrocarbons

• Chemicals

• Beverages and other liquids

The TransPort PT878 flowmeter is a selfcontained, portable ultrasonic flow metering system. Patented Correlation Transit-Time signal processing provides accurate, drift-free flow measurement in liquids that contain a second phase of entrained solids or gas bubbles. The PT878 is suited for all standard transit-time applications, plus many where other transit-time flowmeters fail.

With the PT878, you’ll make your first flow measurement minutes after opening the box.

Input site parameters, clamp the transducers onto the pipe, adjust the spacing, and you’re ready. The PT878 flowmeter is ideal for survey work. An experienced user can take several different measurements in a single day.

The PT878 flowmeter measures flow rate through metal, plastic, or even concrete-lined pipes without penetrating the pipe wall. It ensures non-contaminating, leak-free measurement with drift-free accuracy. With no moving parts to wear or orifices to clog, it doesn't foul, and needs no routine maintenance.

The LCD display menu walks you through data entry and function selection. Alphanumeric mode shows flow velocity, volumetric or energy flow rates, and totalized flow. The display's graphic mode shows real time and logged data, so you can observe trends while you’re on site.

A standard rubber boot protects the flowmeter electronics from vibration and shock.

The sealed housing and ports meet IP67 requirements, and the complete system fits in a compact carrying case.

The PT878 combines ultrasonic flow and temperature measurements to determine the energy flow rate in liquid heating and cooling systems. This energy kit option includes two matched Pt1000Ω surface-mount

RTDs and cable to connect to the PT878. An optional thickness gauge provides accurate wall thickness measurement from outside the pipe, providing a critical parameter used by the PT878 for clamp-on flow measurement.

Live measurements, logged data and site parameter scan be sent to a printer by beaming data from the PT878’s infrared port.

Condensed Specifications

Specs assume a fully developed flow profile, typically 10 diam. upstream and five diam. downstream of straight pipe run), flow velocity >1 ft/sec

Parameters: Volumetric flow, totalized flow, and flow velocity

Flow Measurement: Patented correlation transit-time mode

Fluids: Acoustically conductive fluids, clean liquids or liquids with entrained solids or gas bubbles.

Pipe: Sizes: 0.5” to 300” and larger; Wall Thickness: Up to 3”; Materials: All metal and most plastics. Call RAECO about others.

Range (Bidirectional): -40 to 40 ft/s

Clamp-On Flow Accuracy: Pipe ID <6”: ±2% to 5% reading typical; Pipe

ID >6”: ±1% to 2% reading typical; Depends on pipe size and whether measurement is one-path or two-path

Repeatability: ±0.1% to 0.3% reading

Operating Temperature: -4° to 131° F

Standard Inputs/Output: Two 4-20 mA analog inputs with power supply for loop-powered temperature transmitters; One user-selectable pulse (solid state, 5V max) or frequency (5V square wave, 100-10000

Hz) input; One 0/4-20 mA current output 550Ω max load

Data Logging: Logs more than 100000 flow data points, keypad programmable for log units, update times, and start/stop time

Clamp-On Ultrasonic Flow Transducers: Temperature: -40° to 302° F standard, -328° to 752° F optional, transducer dependent; Mounting:

Stainless steel chain or strap, welded or magnetic clamp fixtures

Digital Interface: Infrared port for communication to printer or PC

Internal Battery: Rechargeable, 9-11 hours continuous operation; Battery

Charger Input: 100-250 VAC 50/60 Hz, 0.38A

Area Classifications: Electronics: General purpose; Transducers: General purpose, weatherproof Type 4X/IP66 or submersible IP67/68

Thickness Gauge (Option): Pipe Thickness: 0.05” to 3”; Pipe material:

Standard metal and plastic pipes; Accuracy: ±1% typical or ±0.002”

Energy Measurement (Option): Calculates energy flow rate and totalized energy. Requires optional energy kit; Temperature transducers:

Loop-powered, 4-wire PT1000 surface-mount RTDs; Accuracy: ±0.12°

C; Range: 32° to 300° F standard.

Model Selection Guide

Description

Portable Liquid Ultrasonic Flowmeter

Case

Ultrasonic

Transducer

Kits

Standard Soft Shell Case

Hard Shell Case

None

-40° to 302° F Use, 2" to 24" Pipes

-40° to 302° F Use, 6"or Larger Pipes*

-40° to 446° C Use, 1/2" to 2" Pipes

-40° to 446° C Use, 2" to 24" Pipes

Catalog

Number

PT-SYS-1-1$5600.00

SC-

H-

0-

A-

C-

B-

F-

Price

0.00

600.00

0.00

1560.00

1560.00

1110.00

2280.00

Accessories

Thickness Gauge

Energy Kit (with RTDs and Cable)

Clamping Fixture

I/O Cable

USB to IR Converter

6-Point Flow Verification Test (NIST)

TG

E

C48

IO

IR

NIST1

560.00

670.00

375.00

100.00

132.00

560.00

* Requires extensions for up to 48" lines, or magnetic clamping fixtures for pipes larger than 24".

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

573

PanaFlow Z3 Three-Path Ultrasonic Flowmeter for Liquids

Features

• No drifting flow measurement

• No restriction in the pipe

• No maintenance or periodic calibration

• No moving parts, filters, or strainers

• Not affected by temperature, pressure, or conductivity

• Three-path design for ±0.5% accuracy, redundancy, and higher visibility to the flow profile

Applications

• Process control and monitoring

• Allocation measurement

• Batching and blending

• Transfer lines

• Cooling water

• Field replaceable transducers for easy maintenance — with no process downtime

• No extended buffers, certified junction boxes, or external cables

Ultrasonic flowmeters help take care of your assets without the maintenance required with other, non-ultrasonic types of flow meters. Hours saved on maintenance, installation and calibration translate directly to the bottom line. With ultrasonic flow measurement there is no drifting, no pressure drop, no restriction in the pipe and no moving parts — nothing to impact the process or damage the meter.

The PanaFlow Z3 is the latest of a new generation of Panametrics ultrasonic flow meters.

It’s a three-path wetted meter designed specifically for low-risk, accurate, repeatable measurement of nominal temperature liquids.

The Z3’s integrated flow cell encloses the transducers, buffers, junction boxes and cables, making it not just an aesthetic design, but a rugged, compact and easy-to-handle meter.

Transducers are removable in the field, so you can replace them easily without shutting down the process. New GE Vitality software is completely intuitive and easy to use.

Three-path technology gives better accuracy and allows for more visibility of the flow profile. It also offers an extra path for peace-of-mind redundancy. New XMT910 electronics, designed for ultra reliability, communicate seamlessly in HART® or Modbus protocol. The integrated transducer system allows for insertion and removal of any of the three pairs of LX transducers without having to isolate the flowmeter or shut down the process.

It offers process and industrial customers ultrasonic benefits and lower cost of ownership than non-ultrasonic flow meters. “The Z3 gives customers the accuracy they need without the

maintenance, installation and calibration costs associated with other flow technologies. Their process can stay up and running without any disruption and in the end, that saves them significant money.”

Condensed Specifications

Fluid Types: Acoustically conductive fluids, including most clean liquids and many liquids with entrained solids or gas bubbles

Flow Measurement: Patented Correlation Transit-Time™ model

Range: -40 to 40 ft/sec, bidirectional

Flow Accuracy: ±0.5% reading for velocities >1.6 ft/sec (0.5 m/sec);

±2.5mm/sec reading for velocities <1.6 ft/sec

Repeatability: ±0.2% reading

Meter Body and Transducer System

Size: 3” to 8” (80 to 200 mm) meter body

Body Material: Carbon steel or stainless steel

Transducers: LX transducers with inserts, 316 stainless steel construction with FKM or EPDM seals

Temperature Range: -40° to 185°F

Pressure Range: Up to maximum allowable flange operating pressure at temperature

Electronics

Paths: Three paths

Operating Temperature: -40° to 140° F

Keypad: Built-in magnetic six-button keypad for full function operation

Power: 100-240 VAC, 50/60 Hz standard, 12-28 VDC optional

Enclosure: Epoxy-coated, copper-free aluminum

Inputs and Outputs: One analog (4-20 mA + HART®) output, one additional 4-20 mA output, two digital outputs (programmable as pulse, frequency, alarm, or control); Additional outputs are compliant to

NAMUR NE 43

Electronics Mounting: Local mounting on meter body

Cable Entries: 3/4” NPT or M20

Approvals: US/Canada Explosion-proof for Class I, Div 1, Groups B-D,

IP67; ATEX and IECEx also available

574

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

AquaTrans AT868 Liquid Ultrasonic Flow Transmitter

Features

• Economical non-intrusive flow measurement

• Simple setup and installation

• Suitable for a wide range of pipe sizes and materials, including lined pipes

• Two channel/two path version available

• Velocity, volumetric, and totalized flow

• Internal keypad for field programming

• Weatherproof Type 4X/IP66 enclosure

• Optional serial communications connection to PC

The AquaTrans AT868 liquid ultrasonic flow transmitter combines state-of-the-art flow measurement capability with a low-cost transmitter package that can be installed right at the measurement point.

It's designed specifically for water and wastewater applications in full pipes. An onboard microprocessor uses patented Correlation Transit-Time technology for long-term, drift-free operation.

Ultrasonic flow transducers are classified as either wetted or non-wetted (clamp-on). Wetted transducers are mounted into the process pipe or flow cell, in direct contact with the process fluid. Clampon transducers are clamped onto the outside of the pipe, and never come into contact with the fluid.

Clamp-on transducers offer maximum convenience, flexibility, and a low installation cost compared to traditional flow metering technologies. With proper installation, wetted transducers provide maximum accuracy (better than 1% reading) in most applications.

The AT868 is available with an optional second channel, providing the capability to measure flow in two pipes, or average two paths on the same pipe for increased accuracy.

Applications

• Potable water

• Wastewater and sewage

• Discharge water

• Treated water

• Heating and cooling water

• Other liquids

Condensed Specifications

Specifications assume a fully developed flow profile, typically 10 diameters upstream, 5 diameters downstream of straight pipe run, and flow velocity greater than 1 ft/sec

Measurement Parameters: Flow velocity, volumetric flow, totalized flow

Fluid Types: Acoustically conductive fluids, including most clean liquids and many liquids with entrained solids or gas bubbles

Range: -40 to 40 ft/sec, bidirectional

Pipe Sizes: Clamp-on transducers: 0.5" to 30" and larger; Wetted transduc-

ers: 1" to 200" and larger

Pipe Wall Thickness: Up to 3"

Pipe Materials: All metals and most plastics. Consult RAECO for concrete, composite materials, and highly corroded or lined pipes

Flow Accuracy: 0.5% reading, achievable with process calibration

Typical Clamp-On Flow Accuracy: Pipe ID <6": ±2% to 5% reading; Pipe

ID >6": ±1% to 2% reading

Typical Wetted Flow Accuracy: ±1% reading

Repeatability: ±0.1% to 0.3% reading

Wetted Ultrasonic Flow Transducers

Temperature Range: -40° to 212° F

Pressure Range: 0 to 300 PSIG

Materials: Stainless steel standard, optional titanium, hastelloy, Monel, duplex, CPVC, PVDF, and others

Process Connections: 1" or 3/8" NPTM standard; Optional RF flanged, socket weld, fuse bond, and others

Mountings: Flanged flow cell, hot tap or cold tap

Area Classifications: General purpose standard, optional weatherproof

Type 4/IP65 or submersible IP67/68

Clamp-On Ultrasonic Flow Transducers

Temperature Ranges: -40° to 302° F standard, -328° to 752° F optional, varies by transducer

Mountings: Stainless steel chain or strap, welded or magnetic clamping fixtures

Area Classifications: General purpose standard, optional weatherproof

Type 4/IP65 or submersible IP67/68

Transmitter Electronics

Flow Measurement: Patented correlation transit-time mode

Enclosure: Epoxy-coated aluminum, weatherproof Type 4X/IP66

Channels: One channel standard, two optional for two pipes or twopath averaging

Keypad: Six-button internal keypad

Display: Two line x 16-character backlit LCD display, configurable to display up to four measurement parameters in sequence

Power: 85–265 VAC 50/60 Hz standard, optional 12–28 VDC ±5%

Operating Temperature: 14° to 131° F

Interfaces: RS232 standard, RS485 optional

Standard Outputs: One 0/4–20 mA isolated output per channel, 600Ω max load; One frequency/pulse rate/totalizer output per channel, optically isolated, 3A max, 100 VDC max, 1W max, from 0.1 to 10 kHz

Software: Optional PanaView™ PC interface software for serial communication to a Windows® computer

Learn more about GE flowmeters at RAECO.com

Call for pricing.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

575

AquaTrans AT600 Single Channel Ultrasonic Liquid Flowmeter

Features

• Non-intrusive flow measurement for less than $2500

• Simple, quick setup and installation — About 30 minutes to unpack, install, and program

• Works with a wide range of pipe materials, even for lined pipes, in sizes from 2” to 24”

• No drifting readings, moving parts, or pressure drop

• Clamp-on installations with new more powerful ultrasonic transducers, improved performance with no risk of leaks

• Permanent solid couplant for clamp-on applications.

Applications

• Potable Water

• Wastewater or sewage

• Discharge water

• Treated water

• Cooling and heating water

• Irrigation water

• Other industrial fluids

GE’s Panametrics AquaTrans AT600 ultrasonic liquid flow transmitter can be installed right at the process measurement point. The AT600 is designed specifically for water and wastewater applications in full pipes, but works with various acoustically conductive liquids.

Fluid types include most clean liquids and many liquids with small amounts of entrained solids or gas bubbles.

The all-digital AquaTrans AT600 has no moving parts and requires minimal maintenance. An onboard microprocessor uses patented Correlation Transit-Time™ technology for long-term, drift-free operation. Automatic adjustment to changing fluid properties and dynamically configured operating software simplify programming.

The flow transmitter offers 4-20 mA analog output plus two discrete outputs standard plus optional Modbus RS485 and HART® communications optional. The front face has a six-button keypad and a graphic LCD display. The hinged front panel can be locked to prevent tampering.

Newly designed clamp-on transducers offer maximum convenience, flexibility and a low installation cost compared to traditional flow metering technologies. These compact 1- or 2-MHz frequency transducers are about 1.33” in size, and come in IP68 rated enclosures. With proper installation, clamp-on transducers provide better than 1% of reading accuracy in most applications.

With pre-installed transducers, easy-to-read spacing markings, and quicktightening stainless strapping, your AT600 sensors can be on the pipe and ready for operation in less than five minutes.

System includes: Single channel weatherproof flow transmitter electronics, clamp-on ultrasonic transducers, transducer cable, transducer rail mount couplant, and traceable calibration certificate

Specifications

Fluid Types: Acoustically conductive fluids, including most clean liquids, and liquids with small amounts of entrained solids or gas bubbles

Flow Measurement: Patented Correlation Transit-Time™ model

Measurement Parameters: Velocity, Volumetric, and Totalized Flow

Pipe Sizes: 2” to 24” standard, other sizes available upon request

Pipe Materials: All metals and most plastics. Call RAECO for concrete, composite materials, and highly corroded or lined pipes

Accuracy: ±1% reading in application; ±0.5% in field calibration; Instal-

lation assumes a fully developed, symmetrical flow profile (typically 10 diameters upstream and 5 diameters downstream of straight pipe run).

Final accuracy is a function of multiple factors including fluid, temperature range, and pipe centricity.

Repeatability: ±0.2% of reading

Range: -40 to 40 ft/sec, bidirectional

Rangeability: 400:1 overall

Electronics

Channels: One channel

Display: 128 x 64 pixel graphic LCD with green or red light error display indicator

Keypad: Six-button keypad, for full functionality operation

Operating Temperature: -4° to 131°F

Outputs: NAMUR NE43 compliant analog outputs, 4–20 mA (24 VDC powered, 600Ω max load); Frequency, Pulse, Alarm (Passive output,

100VDC, 1A/1W max); HART v7.5; Modbus/RS485 (Half-duplex)

Vitality™ PC Interface Software (Optional): AquaTrans AT600 communicates with a PC via Vitality interface program for managing sites, viewing logs, and performing other operations

Power Supplies: 85-265 VAC, 50/60 Hz standard; 12 to 28 VDC, ± 5% optional

Enclosure: Epoxy-coated aluminum weatherproof Type 4X/IP67, mounts easily on a wall or 2” pipe

Calibration: All meters are water calibrated and delivered with a traceable calibration certificate.

Approvals: CE, UL, CSA, MCert

Clamp-On Ultrasonic Flow Transducers

Temperature Ranges: -40° to 302°F standard, -328° to 752°F optional

Operating Frequency: 1 or 2 MHz

Mounting Fixture: Anodized aluminum with stainless steel strapping

Couplant: Solid couplant standard

Rating: General purpose (IP66 or IP68) standard. Exact spec varies by transducer.

576

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

DigitalFlow DF868 Liquid Ultrasonic Energy Meter

Features

• Economical, non-intrusive flow measurement

• Hazardous (classified) location certification

• Suitable for a wide range of pipe sizes and materials

• Two-channel/two-path version available

• Energy measurement option

• Velocity, volumetric and energy flow rates

• Totalized flow and trend data

GE’s DigitalFlow DF868 is a full-featured field-mounted liquid flowmeter. Patented Correlation Transit-Time™ signal processing provides drift-free measurement in ultra-clean and most "dirty" liquids, even those with gas bubbles and entrained solids that historically required the use of Doppler-type meters.

A dual-channel/dual-path model can be configured to measure flow in two separate pipes with a single meter, to reduce the costper-measurement point. Two sets of transducers can be installed on the same pipe to minimize the effects of flow profile distortions, flow swirl and cross flow, and to provide maximum accuracy.

Access to the data you need

Whether single-or dual-channel, all DF868 meters feature two independent graphic LCDs, programmable to fit your application.

Choose from numerical display of real time flow measurements, real time flow graphs and diagnostic waveforms, and numerical/graphic display of data from the meter’s built-in 43,000-point datalogger.

For further functionality, you can add up to 12 isolated 4–20 mA outputs, up to six hermetically sealed or standard alarm relays, and up to 12 frequency/totalizer outputs.

Built-in energy measurement capability

One feature that makes the DF868 even more powerful is the energy measurement software that comes standard in every meter.

Add optional RTDs and input boards to measure both flow and temperature without pipe penetration, in pipe diameters from 1" to 200".

The DigitalFlow DF868 meter measures energy flow in water and water/glycol heating and cooling systems with temperatures from

-4° to 410° F. Call RAECO for use with other liquid systems.

Adjusting to changing fluid properties

GE's unique Automatic Tracking Window™ (ATW) feature — standard in all DigitalFlow DF868 meters — ensures accurate flow measurements, even when fluid properties are unknown or changing. ATW dynamically sweeps the receiver window whenever the sound speed of the fluid changes. This enables flow measurement when the fluid sound speed is unknown, when it changes due to large temperature shifts, or when a new liquid starts to flow in a multiproduct pipeline.

Measure flow from inside or outside the pipe

Applications

• Water and wastewater

• Hot or chilled water

Using clamp-on transducers, the DigitalFlow DF868 measures flow rate through metal, plastic or even concrete-lined pipes without penetrating the pipe wall. The benefits to clamp-on transducers are many — no plugged impulse lines, no pressure drop, and the ability to install sensors while the process unit is in operation.

• Water/glycol solutions

• Refined hydrocarbons

• Petroleum products

• Crude oil, lubricating oil, diesel and fuel oils

• Chemicals and solvents

• Other liquids

To hold clamp-on transducers in place, GE provides clamping fixtures that accommodate different pipe sizes, transducer types and attachment methods. The universal clamping fixture includes ruled slide tracks to simplify transducer spacing for accurate flow measurements, even for transducers on 0.5" to 2" process lines.

Clamp-in wetted transducers can be attached to the inner wall of larger pipes, and come with dual element heads for 100% redundancy.

Precision laser alignment during installation ensures the transducers will work flawlessly. With proper installation, it's possible to achieve transit-time accuracies of better than 1% in most applications, matching the performance of expensive factory-calibrated meters.

For pipes from 1" to more than 200" in diameter, the measurement range is 0.1 to 40 feet/second, with a turndown ratio of 400:1.

Measurement is non-contaminating, obstruction-free, and causes no pressure drop.

The GE DigitalFlow DF868 is all digital, so measurements don’t drift. And, since there are no moving parts to wear out or orifices to clog, it won't need regular maintenance.

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

577

General Specifications

Specifications assume a fully developed flow profile (typically 10 diameters upstream and 5 diameters downstream of straight pipe run) and flow velocity greater than 1 foot/second.

Flow Measurement: Patented Correlation Transit-Time mode

Measurement Parameters: Flow velocity, volumetric flow, totalized flow

Fluid Types: Acoustically conductive fluids, including most clean liquids, and many liquids with entrained solids or gas bubbles. (Maximum void fraction depends on transducer, interrogation carrier frequency, path length and pipe configuration.)

Measurement Range: -40 to 40 feet/second, bi-directional

Rangeability: 400:1

Pipe Sizes: Using clamp-on transducers: 0.5" to 300" and larger; Using

wetted transducers: 1" to 200" and larger

Pipe Wall Thickness: 3" max.

Pipe Materials: All metals and most plastics. Call RAECO for concrete, composite materials, and highly corroded or lined pipes.

Flow Accuracy (Velocity): ±0.5% reading (achievable with process calibration); Typical Clamp-On Flow Accuracy: Pipe ID ≤6": ±2% to 5% reading; Pipe ID >6": ±1% to 2% reading; Typical Wetted Flow Accuracy:

±1% reading; Accuracy depends on pipe size, installation and whether

measurement is one-path or two-path.

Repeatability: ±0.1% to 0.3% reading

Input Channels: One channel standard, two channels optional for two pipes or two-path averaging

Power Supply: 100 to 130 VAC, 50/60 Hz or 200 to 265 VAC, 50/60 Hz

Operating Temperature: -4° to 131° F

Outputs (Standard): Two 0/4 to 20 mA isolated outputs standard, 550Ω maximum load NAMUR NE043 compliant; There are six additional slots available for any combination of I/O boards:

Analog Outputs (Option): Three additional output boards, each with four isolated 0/4 to 20 mA outputs, 1000Ω maximum load

Analog Inputs (Option): Select up to three boards: Two isolated 4 to 20 mA inputs and 24 V loop power, RTD input board with two isolated, three-wire, 100Ω RTD inputs; span -148° to 662°F

Totalizer/Frequency Outputs (Option): Select up to three boards, four outputs per board, 10 kHz max. All boards allow software-selectable functioning in totalizer or frequency mode. Totalizer mode: Pulse per defined unit of parameter; Frequency mode: Pulse frequency proportional to magnitude of parameter

Alarm Relays (Option): Select up to two boards of the same type: General

purpose: Relay board with three Form C relays; 120 VAC, 28 VDC max,

5A max; 30 W DC max, 60 VA AC; Hermetically sealed: Relay board with three hermetically sealed Form C relays; 120 VAC, 28 VDC max, 2A max,

56 W DC max, 60 VA AC

Electronics Enclosure: Standard epoxy-coated aluminum weatherproof

Type 4X/IP66 Class I, Div 2, Groups A–D; Optional stainless steel, fiberglass, explosion-proof or flame-proof housing

Display: Two independent software-configurable 64 x 128-pixel backlit

LCD graphic displays for numerical or graphical data

Keypad: 39-key tactile feedback membrane keypad

Power Consumption: 20 W max

Digital Interfaces: RS232 standard; RS485, Modbus RTU, Modbus TCP,

OPC server, Ethernet optional

Data Logging: Memory capacity (linear and/or circular type) to log more than 43,000 flow data points

Communications: Serial communications to a PC with Windows operating system, uses PanaView™ PC interface software

Learn more about GE flowmeters at RAECO.com

Call for pricing.

Energy Measurement

Function: Calculates energy flow rate and totalized energy usage.

Requirement: Requires optional RTD or analog inputs to the DF868 with two temperature inputs: one for supply and one for return temperature.

Installation: Typical installations use surface mount RTDs with integrated 4-20 mA transmitters, but wetted RTDs with thermowells are available if more accuracy is required and if the line can be shut down for installation.

Surface Mount RTDs: Pt1000Ω, 4-wire, matched pair with integrated

4-20 mA transmitters; Range: 32° to 122° F or 32° to 302° F

Wetted Ultrasonic Transducers

Temperature Ranges: -40° to 212° F standard; -310°to 1112° F optional

Pressure Ranges: 0–3000 PSIG standard; Higher pressures available on request

Materials: Stainless steel standard; Optional Titanium, Hastelloy, Monel, and duplex; Pan-Adapta plugs allow installation and removal of wetted transducers without interruption the process or emptying the pipe

Process Connections: 1" or 3/8" NPTM standard; Also available with RF flange, socket weld, fuse bond, or others

Mounting: Flanged flow cell, hot tap or cold tap

Area Classifications: General purpose standard; Also available with

Weatherproof Type 4X/IP65; Explosion-proof Class I, Div 1, Groups

C–D; Class II, Groups E–G; Class III; Flameproof II 2 G EEx d IIC T6; or submersible

Clamp-On Ultrasonic Flow Transducers

Temperature Range: -40° to 302°

F standard; -328° to 752° F optional; See specific transducer for exact temperature range

Mountings: Stainless steel chain or strap, welded or magnetic clamping fixtures

Area Classifications: General purpose standard; Also available with

Weatherproof Type 4X/IP66; Explosion-proof Class I, Div 1, Groups

B–D; Class II, Groups E–G; Class III; Flameproof Ex II 2 G EEx md IIC

T6-T3; or submersible

Transducer Cables: One pair of coaxial cables, type RG62 AU, or as specified for transducer type' Lengths up to 1,000 ft (330 m) maximum

578

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

DigitalFlow GF868 Flare Gas Mass Ultrasonic Flowmeter

Learn more about GE flowmeters at RAECO.com

Call for pricing.

Features

• Measures velocity, volumetric and mass flow

• Velocity range to 328 ft/sec standard, 394 ft/sec extended

• Measures instantaneous average molecular weight

• Minimal maintenance — no moving parts, no holes or tubes, tolerant to dirty and wet conditions

• Measures hydrocarbon gases

• Built-in totalizers, built-in power supply for pressure and temperature transmitters

• 3940:1 turndown ratio

• One- or two-channel/path configurations

Applications

• Track down or prevent losses from leakage with positive material ID

• Account for total plant material throughput

• Reduce cost of steam usage with proportional control

• Conserve energy by eliminating unnecessary flaring

• Comply with government regulations for pollution control

• Also measures vent gas

The DigitalFlow GF868 ultrasonic flowmeter uses patented Correlation Transit-Time technique, digital signal processing, and an accurate molecular weight calculation to provide you reliability and high accuracy with no routine maintenance required.

Typically, gas in flare stacks, headers, or laterals is a mixture of components from different sources. Flow rate in flare systems can be unsteady and even bidirectional. Pulsating pressure, varying composition and temperature, harsh environment, and wide flow range further complicate these measurements. Correlation transit-time measurement provides superior performance under these conditions.

The all-metal ultrasonic transducers installed in the pipe send sound pulses upstream and downstream through the gas. The GF868's onboard computer uses advanced signal processing and correlation detection to calculate velocity and volumetric and mass flow rate.

For maximum accuracy, the two-channel version measures along two paths at the same location.

Condensed Specifications

Measurement Parameters: Mass flow, standard and actual volumetric flow, totalized flow, molecular weight, speed of sound, flow velocity

Measurement Type: Correlation transit-time mode

Fluid Types: Flare and vent gases

Pipe Materials: All metals and fiberglass

Pipe Sizes: 2" to 14" diagonal 45°, 16" to 120" bias 90°

Range: -328 to 328 ft/sec, bidirectional

Accuracy: Flow: ±1 to ±328 Ft/sec: ±2–5% one path, ±1.4–3.5% two path;

0.1 to ±1 ft/sec: ±0.15 in/sec one path, ±0.12 in/sec two path; Molecular

weight: 2 to 120 gr/gr mole hydrocarbon mixtures; Mass flow: 3 to 7% one path, 2.4 to 5% two path

Standard Inputs/Outputs: Two isolated 0/4–20 mA inputs with 24 VDC power; Six 4–20 mA output, two with 550Ω max load, four with 1000Ω max load; NAMUR NE43 compliant

PanaFlow HT Ultrasonic SIL Liquid Flowmeter

• For coker crude or vacuum distillation, crackers, hydrotreaters, visbreakers, crude oil, and liquefied natural gas

• No drifting flow measurement

• No maintenance or periodic calibration required

• No restriction in the pipe

• Reliable measurement by design (IEC 61508 certification pending)

• Flow measurement in extremely low (-328°F) or high (1112° F) temperature applications

• Bidirectional measurement

Call for pricing.

PanaFlow HT —the first SIL-rated ultrasonic flowmeter on the market — measures liquids in either nominal or extremely high or low process temperatures. As a safety flowmeter, or coker flowmeter, the PanaFlow HT is designed for use in safety-critical applications where reliability ensures reduction in risk to personnel, plant assets, the environment, and to your corporate reputation.

The PanaFlow HT is a wetted ultrasonic flowmeter gives you confidence in your flow measurement, providing reliable flow meter operations for both safety and process control systems.

The PanaFlow HT system consists of the new XMT900 electronics, a bundle waveguide transducer (BTW) system, and a meter body.

The meter body comes in a variety of configurations for pipe sizes up to 16" standard, and is available in several materials and finishes.

Condensed Specifications

Fluid Types: Acoustically conductive liquids, including most clean liquids and many liquids with small amounts of entrained solids or gas bubbles

Meter Sizes: 3" to 16" standard, sizes to 36" available on request

Range: 0.1 to 40 ft/sec, bidirectional

Accuracy: ±0.5% to ±0.9% reading, depending on meter size, flow range

SIL Certification: IEC 61508 (pending, SIL2 certification with single design system, SIL3 certification with redundant design system

Meter Body: Carbon steel, stainless steel, and 9Cr-1Mo

Flow Transducer: Bundle waveguide technology, 316L SS transducer and holder; Temperature: -310° to 600° standard, -310° to 1112°F high temperature liquids; Approvals: Explosion-proof Class I, Div 1, Groups

B–D, ATEX Flameproof II 2 G Ex d IIC T6, IECEx Flameproof Ex d IIC T6

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

DigitalFlow GS868 Ultrasonic Steam Mass Flowmeter

Features

• Non-obstructive flow measurement

• No moving parts, low maintenance

• No pressure drop

Applications

• Ventilation systems (HVAC)

• Pneumatic power systems, electric power generation, and public works • Wide rangeability with 1500:1 turndown ratio

• Tolerant to dirty streams, high temperatures

• Two-path measurement for maximum accuracy

• Water purification and distillation

• Chemical and petrochemical

GE;s DigitalFlow GS868 steam ultrasonic flowmeter measures the mass flow rate of saturated or superheated steam. Conventional steam flowmeters cause a permanent pressure drop and have limited

• Food and beverage industries

• Steel industry rangeability, wasting time and money. Since the DigitalFlow GS868’s transducers do not obstruct the flow, they don’t cause pressure drop. Plus, it has no parts that foul or collect debris, and no moving parts to wear out. So, the GS868 requires no lubrication, cleaning or routine maintenance.

The GS868 flowmeter system consists of one or two pairs of transducers, preamplifiers and an electronics console. The transducers can be installed as part of a flowcell, or installed directly into the existing pipeline. The electronics console can be mounted up to 500 feet from the transducers.

For maximum accuracy, use a two-channel meter to measure along two different paths at one location. A two-channel meter can also measure the flow in two separate pipes for added cost savings.

In addition to velocity, volumetric and mass flow data, the DigitalFlow GS868 provides diagnostic parameters such as transit times and sound speed, to aid in setup and troubleshooting. Any of this data can be easily printed, logged, sent to an analog or digital output, or read in numeric or graphic format on the dual window display.

The DigitalFlow GS868 flowmeter makes it easy to send the data where it needs to go, through digital or analog outputs, or optional alarms.

Rugged Field-Mount Transmitter Version Available

If you’d prefer a more rugged field-mount transmitter for Class I, Div 1 environments the

DigitalFlow XGS868i offers the same functionality in a field-hardened enclosure.

579

Condensed Specifications

Fluid Types: Saturated and superheated steam

Flow Measurement: Patented Correlation Transit-Time mode

Pipe Sizes: 2” to 48” nominal bore

Pipe Materials: All metals. Call RAECO for others.

Range: -150 to 150 ft/s bidirectional

Flow Accuracy (Velocity): ±1% to 2% of reading typical; Repeatability:

±0.2% to 0.5% of reading

Rangeability (Overall): 1500:1

Measured Parameters: Mass flow, standard and actual volumetric flow, totalized flow, and flow velocity

Electronics

Operating Temperature: -4° to 131°F

Pressure Ranges: 0 to 2700 psig standard; 3480 psig max optional

Enclosures: Standard: Epoxy-coated aluminum weatherproof Type

4X/IP66, FM/CSA Class I, Div 2, Groups A-D; Optional: Stainless steel, fiberglass, explosion-proof, flameproof, ISSep 03ATEX113

Channels: One channel standard; Two optional for two pipes or twopath on one pipe

Keypad: 39-key tactile-feedback membrane keypad for on-site parameter programming

Display: Two independent software-configurable 64 x 128 pixel backlit

LCD graphic displays; Functions: Graphic display shows flow in numerical or graphic format; Shows logged data and diagnostics

Input/Output (Standard): Two 0/4 to 20 mA isolated outputs, 550Ω max load

Input/Output (Options): Six additional slots for any combination of

I/O boards: Analog outputs: Four isolated 0/4–20 mA outputs; Analog

input: Two isolated 4–20 mA inputs and 24 V loop power; RTD input:

Two isolated, three-wire, RTD inputs, span -148° to 662°F; 100Ω; Total-

izer/frequency outputs: Pulse per defined unit of parameter or pulse frequency proportional to magnitude of parameter; Alarm relays:

General purpose or Hermetically sealed

Data Logging: Memory capacity to log more than 43,000 flow data points

Transducer Construction: Titanium or stainless steel standard

Area Classifications: Standard: Weatherproof Type 4/IP65; Optional:

Explosion-proof Class I, Div 1, Groups C&D, Flameproof II 2 G EEx d IIC T6

Additional Options

Digital Interfaces: RS232 Standard; Options: RS485, Modbus® RS485 or

TCP, Ethernet, OPC server

PanaView PC-Interface Software: Communicates with a Windows® PC through a serial interface

580

RAECO LIC-LLC www.RAECO.com [email protected]

Illinois Operating Office

135 Bernice Drive

Bensenville, IL 60106-3366

Wisconsin Operating Office

5160 North 125th Street

Butler, WI 53007-1332

Sales: 800-852-9795

Rentals: 866-RENT-EHS

Fax: 815-464-8720

PORTABLE INSTRUMENTATION RENTALS

Products in this catalog are available to rent anywhere in the US. Due to representative agreements with our manufacturer partners, not all products are available for sale in all areas and markets. Prices are current at publication, and are subject to change without notice.

See

Page

Industrial Hygiene Instrumentation

Ventilation Testing and Balancing

Indoor Air Quality

Air Sampling Pumps and Calibrators

Particulate Monitors and Aerosol Particle Counters

Sound Level Monitors

Non-Destructive Testing Instruments

580

580

581

578

585

584

Portable Safety Instrumentation

Area and Personal Heat Stress Monitors

Emissions Monitoring and Combustion Efficiency

Non-Destructive Testing Instruments

Portable and Personal Gas Detection

Refrigerant, Gas Leak, and Contaminant Detectors

Respirator Fit Testing Systems

Personal Noise Dosimeters

Radiation Exposure Testing

Volatile Organic Compound Detectors

Environmental Monitoring Instrumentation

Perimeter Dust Monitoring Kits 579

579

584

584

582

583

586

585

585

583

577

Rental Service That Treats You Right...

RAECO Rents is here to help you fulfill your most important objectives.

First, to get the instrumentation you need, when you need it. Second, to get instrumentation that works. Third, to make sure you can use the instruments to their fullest capability. We want you to have a great experience working with RAECO Rents!

Free Round-Trip Ground Shipping!

Free round-trip UPS Ground shipping on every rental one week or longer in duration. If you need the rental faster than Ground shipping allows, you only pay the difference for the upgraded delivery to your location (the

Ground return is still free). Good on qualifying rentals booked and shipped thru Dec. 31, 2013, and shipped from the RAECO Rents service locations.

RAECO Rents Instant-On Guarantee

If our equipment doesn’t arrive in working order, your rental is FREE for as many days as it takes us to get you a working unit. So, if we ship you a unit that doesn’t work out of the box, and the replacement takes two days to arrive, you won’t pay for those two days — and we’ll add two free rental days to make up for any lost time.

Get your rental late? Let us know. If your rental equipment has been held up by bad weather, issues with the carrier, or other factors beyond our control, call us. We’ll adjust the rental period to satisfy your requirements (and you won’t be charged for the additional time.)

Easy Return Procedures

We include a return shipping label and packing tape in every rental kit for easy rental return. If we need the rental back sooner, we may ask you to use a priority label that we generate at our cost. You just stick the label on the box and drop it off at any one of UPS’s 40,000 drop points.

Visit UPS.com to find the UPS location closest to you.

After-Hours Support

If you rent from us and need support during non-business hours (8am–

5pm CST), call 866-736-8347 x2000, and leave us a message. Our on-call rental technician will call you back as soon as possible.

Buy Gently Used Instruments on eBay!

Using an instrument more often than it’d make sense to rent? Short on the budget needed to buy a brand new unit? Are you in the market for gently used instrumentation? Check out RAECO Rents’ new eBay store! We sell gently used units out of our rental pool to help customers balance their demand and budgetary needs.

Visit stores.ebay.com/raecorents

linkd.in/Rents

We Want to Connect with You

bit.ly/RentsVids bit.ly/RentsTweet

Subscribe to our IH and safety blog:

blog.RaecoRents.com

578

RAECO Rents LLC www.RAECORents.com [email protected]

Rental Operations Office

135 Bernice Drive

Bensenville, IL 60106-3366

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Aerosol Particulate Counters and Concentration Monitors

TSI DustTrak™ DRX for Mass

Concentration and Total PM Size

TSI 8533 Desktop Unit TSI 8534 Handheld Unit

SidePak™ AM510 Intrinsically Safe

Personal Aerosol Monitor

Kit includes soft single-unit

carrying case, 115/230 VAC power supply/charger, extended run NiMH battery + AA

Alkaline battery pack, line power cord, impactor

AM510 Aerosol Monitor

kit, cyclone kit, screwdriver, T rak

P ro

™ data analysis software CD, USB cable, zero filter, sample tube, user

$75.00

Daily

$220.00

Weekly

Call Us!

guide, battery maintenance card, calibration certificate, and quick reference card.

$150.00

Daily

$425.00

Weekly

Call Us!

$150.00

Daily

$425.00

Weekly

Call Us!

DustTrak DRX 8533 rental kit includes desktop unit, rechargeable 6600 mAH

Lithium Ion battery x 2, switching power supply with universal line cord, zero filter,

TrakPro data analysis software CD, USB computer cables, inlet caps, HEPA filters, calibration impactor kit with PM2.5 impactor, two impactor plates, impactor oil,

37mm cassette with mesh filter, stylus, 3' sample extension tube, filter removal tool, user manual, calibration certificate, and carrying case.

DustTrak DRX 8534 rental kit includes handheld unit, rechargeable 3600 mAH

Lithium Ion battery, switching power supply with universal line cord, zero filter, inlet caps, USB computer cables, impactor kit with oil, PM2.5 impactor and impactor plate, screwdriver, three-foot sample extension tube, sheath air HEPA filters, filter removal tool, stylus, TrakPro data analysis software CD, user manual, calibration certificate, and carrying case.

pDR-1000AN DataRAM

Personal Aerosol Monitor

Kit ships with soft shell carrying

case, digital communications cable

Z-pouch zeroing kit, belt clip kit, AC power supply, battery charger, analog output cable, communications software, 20-hour 9V battery, and calibration certificate.

$75.00

Daily pDR-1000AN

$200.00

Weekly

Call Us!

See more personal sampling pumps on page 581.

DustTrak™ II for Mass Concentration of Aerosols

Functional replacement for the retired TSI

8520

TSI 8530 Desktop Unit

$100.00

Daily

$300.00

Weekly

Call Us!

DustTrak II 8530 kit includes desktop unit, rechargeable 6600 mAH Lithium Ion

battery, switching power supply with universal line cord, zero filter, TrakPro software

CD, USB computer cables, analog, inlet caps, 10mm Nylon Dorr-Oliver cyclone, impactor kit with PM1, PM2.5, PM4, and PM10 impactors, two impactor plates, impactor oil, sheath air HEPA filters, 3' sample extension tube, two 37mm cassettes with screen, stylus, filter removal tool, user manual, calibration certificate, and carrying case.

AeroTrak 9306 Optical Particle Counters

Choose your model:

9306-01: Six fixed bin sizes 0.3–5

mm

9306-V2: Six adjustable bin sizes 0.3–10

mm

AeroTrak 9306-01 or V2

9306-01 ships with isokinetic inlet,

purge filter, rechargeable Lithium Ion

$70.00

Daily

$210.00

Weekly

Call Us!

battery, power supply, zero HEPA filter, inlet cap, USB cable, TrakPro Lite download software, stylus, manual, quick-start guide, calibration certificate, and carrying case.

9306-V2 ships with 9306-01 kit contents plus isokinetic hose barb

and tubing.

TSI 8535 Weatherproof Enclosure for

DustTrak™ Monitors

Protect your dust monitor rental from rain, wind, and bad weather.

TSI 8535 Field Enclosure

$50.00

Daily

$95.00

Weekly

Call Us!

DustTrak 8535 rental kit includes weatherproof

case with survey tripod mount, 360° sampling inlet, water trap bottle, dust caps, internal equipment bracket with Velcro straps, tubing, plug, O-rings, weatherproof AC/DC adapter, internal battery system, USB cable, universal power supply, modem configuration software CD and user manual.

Rent the 933MHz wireless radio modem kit, dipole antenna, and charger separately.

Particle sizes

<1mm

P-Trak® 8525 Ultrafine Particle Counter

Ships with tube, sample probe,

shoulder strap, inlet screen, spare wicks, alcohol fill capsule, storage cap, cartridge, four 30ml bottles

P-TRAK 8525

isopropyl alcohol, two zero filters,

T rak

P ro

software, USB cable, DB9/

$100.00

Daily

$315.00

Weekly

Call Us!

DB25 serial adapter, battery holder, six AA batteries, carrying case, calibration certificate, and manual.

TrakPro™ Software Included!

All rentals for TSI products compatible with T rak

P ro

data analysis software include the CD! Download the latest T rak

P ro

version from RaecoRents.com

TrakPro complies to FDA 21 CFR Part 11 by offering secure and reliable data collection and classification for the AeroTrak® handheld and portable airborne particle counters, as well as the BioTrak® real-time particle counters. Unique user names and passwords, audit trail, password aging, and lockout after failed logins, means secure, tamper proof data transfer. Assigned security privileges control access and activity.

3M Quest EVM-7 Particulate/Air Quality Monitor

Kit includes base model with PID

sensor, CO2 sensor, CO sensor, two

37mm gravimetric filter cassettes,

12 VDC universal power supply,

EVM-7/CO

USB cable, impactor grease, PID cleaning kit, pump protection

$150.00

Daily

$300.00

Weekly

Call Us!

filters, dust zero calibration filter assembly, toxic calibration adapter, user manual, QuestSuite Pro II software, calibration certificate, and carrying case.

RAECO Rents LLC www.RAECORents.com [email protected]

Rental Operations Office

135 Bernice Drive

Bensenville, IL 60106-3366

Perimeter Monitoring Kits

RAECO Rents offers complete ready-to-place kits for monitoring environmental dust exposure for community air monitoring programs, local, state, and federal air quality control programs, and more.

We’ve simplified the process of renting perimeter environmental air quality and dust monitoring systems, by pre-configuring a kit that includes all the parts you need: a dust particulate monitor, power supply, wireless data radio, weather-safe enclosure, tripod, and a weather station.

Order as few or as many as you need to accurately cover the perimeter of your working environment. Depending on your application, you may want to order a kit with an attached weather station for monitoring temperature and humidity change, wind speed, and wind shifts.

When you order a perimeter monitoring system from RAECO Rents, you’ll get access to our secure data center, where you’ll be able to see real-time results from your monitoring kit and generate reports using your PC, tablet, or cell phone.

With a short training and setup call, you’ll be able to install the equipment in the field, and start accessing real-time data over a secure web portal from your web browser (tested to work on PCs, IOS and Android tablets and mobile phones).

View your data from any PC, tablet, or phone’s web browser.

Rent a Perimeter Monitoring System

Want to learn more? Take this shortcut to our website:

mobibrix.com/H4DC5G

Click on "Get a Quote" and fill out the details of your application. We'll configure the number of units you need with all components.

Rentals: 866-RENT-EHS

Fax: 815-464-8720

579

(1) Monitor particulate around your perimeter. (2) Real-time results transfer wirelessly to a secure data center. (3) View, analyze, and prepare reports directly from your desktop, laptop, or mobile device using a standard web browser.

Key Specifications

• TSI DustTrak II 8530 measures aerosol particulate concentrations to PM10, PM2.5, PM1.0 or respirable size fraction

• TSI 8535 DustTrak environmental enclosure houses the measurement devices, power supplies, and data management hardware

• Netronix Thiamis ICU-820 combines control, datalogging, GPS, and GSM cellular modem communications. Sends data from each monitoring kit to a secure data center

• Includes secure access to Environet, for viewing data and creating reports using your PC or mobile device and a web browser.

• Optional weather station measures wind speed and direction, air temperature, air pressure, and humidity

Need your system to measure VOCs?

Monitor sound levels?

Call us for help building the exact perimeter monitoring kit to fit your application needs.

Heat Stress Monitors

NOT intrinsically safe.

QUESTemp Portable Heat Stress Monitors

Intrinsically safe QT-36 kit

ships with sensor bar mounted

with wet bulb, dry bulb, and black globe thermometer, 12"

QUESTemp 36

probe, spare wicks, water bottle,

9V battery, serial cable with USB

$65.00

Daily

$175.00

Weekly

Call Us!

adapter, QuestSuite II software CD, calibration certificate, carrying case, and user manual.

QT-46 ships with sensor bar

with black globe thermometer, dry bulb thermometer, and RH sensor; verification module, 9V battery, serial cable with USB adapter, CD driver, instructions,

QuestSuite II software, calibration certificate, user manual, and carrying case.

Air Probe-120 Add on (use

with QT-46 only) for true wet-bulb calculations.

$65.00

Daily

$20.00

Daily

QUESTemp 46

$175.00

Weekly

Air Probe-120

$70.00

Weekly

Call Us!

Call Us!

QUESTemp II Personal Heat Stress Monitor

Pocket-sized unit measures and logs core body temperature. Audible alarms indicate elevated temperatures to minimize worker heat stress risk.

QuesTemp II (Single)

$150.00

Weekly

Call Us!

QuesTemp II (5-Pack)

QT-II ships with monitor, cable for ear sensor,

thermoplastic earmold with speaker assembly, 10 replacement expandable foam ear plugs, digital oral thermometer, 10 oral thermometer disposable sheaths, serial cable with USB adapter, QuestSuite

Pro II software CD, storage case, and user manual.

$175.00

Daily

$750.00

Weekly

Call Us!

5-Pack kit includes five QT-II monitors with cables, earmold speaker assemblies, 50

expandable foam ear plugs, plus one digital oral thermometer, 10 oral thermometer disposable sheaths, serial cable with USB adapter, QuestSuite Pro II software CD, storage case, and user manual.

Data Management Software Included!

All 3M Quest rentals come with QuestSuite Pro II and 3M Detection

Management Software free. Download today at www.RaecoRents.com

580

RAECO Rents LLC www.RAECORents.com [email protected]

Ventilation Test Instruments

Rental Operations Office

135 Bernice Drive

Bensenville, IL 60106-3366

VelociCalc® 9555 Multi-Function

Ventilation Meter

Includes static pressure tip, rubber tubing,

USB cable, LogDat and TrakPro software, user manual, carrying case, instrument and probe calibration certificates, power supply, and four AA Alkaline batteries.

Choose probes from the list below.

VelociCalc 9555-P

$30.00

Daily

$80.00

Weekly

Call Us!

9565 adds ability to measure dP, VOCs, plus temperature (with Type K thermocouple probes).

Measures

10–500 CFM

Rentals: 866-RENT-EHS

Fax: 815-464-8720

TSI Alnor 6200D LoFlo Balometer

Includes 2’x2’ air capture

hood, frame, base, manometer, wheeled luggage-style carrying case, four C Alkaline batteries,

NIST calibration certificate, and user manual.

LoFlo Balometer 6200D

$65.00

Daily

$160.00

Weekly

Call Us!

VelociCalc® 9565 Multi-Function

Ventilation Meter

Includes dP sensor and static

pressure tip, rubber tubing,

USB cable, LogDat and TrakPro software, user manual, carrying

VelociCalc 9565-P

case, instrument and probe calibration certificates, power

$30.00

Daily

$80.00

Weekly

Call Us!

supply, and four AA Alkaline batteries. Choose probes below.

Probes for Ventilation Testing (L to R)

• 995 rotating vane probe

• 964 air velocity probe

• 982 indoor air quality probe

• 985 volatile organic compounds probe (9565 only)

• 634634004 Pitot probe (Free: just ask for it!)

Add Probes to Extend VelociCalc Applications D W M

964 Air Velocity Probe (Velocity/Temperature/Humidity) $20.00 $70.00 Call

982 IAQ Probe (Temperature/Humidity/CO/CO2)

985 VOC Probe (Temperature/VOC ppm)

995 Rotating Vane Probe (Velocity/Temperature)

966 Articulating Probe

30.00 100.00 Call

55.00 165.00 Call

10.00 40.00 Call

70.00 160.00 Call

Measures

0–2500 CFM

TSI Alnor EBT731 Balometer/Electronic

Balancing Tool

Replacement for retired

TSI AccuBalance Plus 8375

Alnor EBT731

Ships with instrument, base

assembly, 2' x2' hood, 18" Pitot probe, two static pressure probes, two 8' hoses, battery charger, four

$70.00

Daily

$200.00

Weekly

Call Us!

Alkaline batteries, LogDat1 software, interface cable, calibration certificate, and wheeled carrying case.

Need a temperature/humidity probe, or a 1’x4’ or 2’x4’ hood and frame kit? Each available for $12.00/day, $35.00/week.

DP-Calc™ 8710-XX1

Micromanometer Kit with Probes

Ships with 16-point velocity

matrix, air flow probe, 18"

Pitot probe, two static pressure probes, two Neoprene

DP-Calc™ 8710-XX1

tubes, battery charger, four AA Alkaline batteries, neck strap, AC adapter, serial cable, telescoping

$65.00

Daily

$190.00

Weekly

Call Us!

handle, L og

D aT

software, NIST calibration certificate, carrying case, and manual.

Need a temperature/humidity probe? Rent it! $12.00/day, $35.00/week.

Indoor Air Quality Measurement

IAQ-Calc™ 7545 Indoor Air Quality Meter

Ships with instrument, four AA Al-

kaline batteries, PC cable, download software CD, probe stand, CO2 and

CO calibration collars, AC adapter, carrying case, calibration certificate, and manual.

IAQ-Calc™ 7545

$60.00

Daily

$180.00

Weekly

Call Us!

Q-Trak™ 7565 Indoor Air Quality Monitor

Ships with 982 IAQ probe and stand,

CO/CO2 calibration collar, Alkaline batteries, AC adapter, serial cable,

DB9/DB25 adapter, TrakPro software, calibration certificate, carrying case, and user manual.

$60.00

Daily

Q-Trak™ 7565

$180.00

Weekly

Call Us!

Add Probes for Other Air Quality Measurements D W M

964 Air Velocity Probe (Velocity/Temperature/Humidity) $20.00 $70.00 Call

995 Rotating Vane Probe (Velocity/Temperature)

966 Articulating Probe

10.00 40.00 Call

70.00 160.00 Call

What can you learn at RaecoRents.com?

• How to use TSI PortaCount Pro for fit testing

• How to use the Svantek SV-106 vibration testing system

• How to download data from 3M Quest noise dosimeters or

BW GasAlert gas detectors

• Using an Ion Science PhoCheck Tiger PID with PC software

More tutorials and videos added every week!

Learn more at RaecoRents.com

Specs, manuals, quick-start guides, software, and free training videos available 24 x 7 x 365!

RAECO Rents LLC www.RAECORents.com [email protected]

Rental Operations Office

135 Bernice Drive

Bensenville, IL 60106-3366

GilAir Plus 5-Liter Universal Air Sampling Pump

• Pressure and temperature calibrated, with datalogging feature

• Constant flow 25-5000 cc/min, constant pressure

1-5000 cc/min

• High-flow and low-flow constant pressure, constant flow — no adapters required

• Up to 40” H2O back pressure in high flow, up to 25” H2O in low flow

• Automatically performs restart to recover from temporary faults

• Dock provides charging plus communication to PC or calibrator

• Battery proven to last 12 hours on a single charge

Single kit includes one sampling pump, single station com-

munication/charging dock, USB cable, AC power supply, filter cassette holder, charcoal tube holder, pump management software, hex wrench, user manual, certificate of performance, and carrying case.

5-Pack kit includes five each: sampling pump, filter

cassette holder, charcoal tube holder, certificate of performance plus one each: five-station communication/charging dock, AC power supply, hex wrench, pump management software, user manual, and carrying case.

$150.00

Daily

GilAir Plus (Single)

$100.00

Weekly

$450.00

Weekly

Call Us!

GilAir Plus (5-Pack)

Call Us!

Gilian 5000 5-Liter Live Flow Air Sampling Pump

Need high back pressure?

Gilian 5000 is the pump for you!

Gilian 5000

Comes with 1000-5000 cc/min pump, low

flow constant pressure adapter, NiMH battery, charger, filter cassette holder, US 120/240V

$75.00

Weekly

power cord, 36” tubing, user manual, and carrying case.

Call Us!

GilAir-5 5-Liter Constant Flow

Sampling Pump

GilAir-5 (Single)

Kit includes one 750-5000 cc/min pump,

low flow (20-500 cc/min) module, 120 VAC charger, filter cassette holding kit, air boss kit, 35" tubing, screwdriver, tool kit, carrying case, and user manual.

$75.00

Weekly

Call Us!

GilAir-5 (5-Pack)

5-pack pump kit includes five pumps and low flow

modules, five-station charger, filter cassette holding kit, air boss kit, 35” tubing, screwdriver, tool kit, carrying case, and user manual.

$100.00

Daily

$350.00

Weekly

Call Us!

Most units also available for sale. Visit bit.ly/RentsGU or call

866-RENT-EHS for prices on gently used instruments.

Don't Forget Your Pump Accessories!

Gilian Dorr-Oliver Cyclone

$6.00

Daily

$20.00

Weekly

Call Us!

Gilian Calibration Jar

$2.00

Daily

$3.00

Weekly

Call Us!

Free with a pump rental!

• 37mm Filter Cassette Kit: 37mm filter cassette, sampling tubing, U-tube, Luer adapter, lapel clip.

• Adjustable Sorbent Tube Kit: Tube holder, 6mm x

70mm tube cover, sample tubing, and lapel clip

$5 flat fee each for any rental duration!

For use with all

RAECO rental pumps.

Rentals: 866-RENT-EHS

Fax: 815-464-8720

581

Air Sampling Pumps

Bio-Pump® Plus Particulate

Sampling Pump

Kit includes Bio-Pump Plus, low-flow

resistance filter, Air-O-Cell flow meter,

Air-O-Cell CSI flow meter, cassette manuals, instructional DVD, A/C adapter, user manual, and carrying case.

Bio-Pump® Plus

$75.00

Weekly

Don’t forget to buy a 10-pack of sampling media

Air-O-Cell Cassettes For mold spores, pollen, insect parts, skin cells, fibers and inorganic particulate.

Call Us!

Price

$45.00

Air-O-Cell CSI Cassettes For viable and non-viable particulate, like mold spores, pollen, insect parts, skin cell fragments, fibers

(asbestos, fiberglass, cellulose, etc.) and inorganic particles.

Via-Cell Cassettes For viable and non-viable bioaerosols maintains viability of the mold spores and prevents growth during transport to the lab.

95.00

125.00

Air Flow Calibrators and Accessories

Challenger Precision Air Flow Calibrator

1 to 30 LPM

Kits include unit, venturi for high and low

flow calibration, four AA batteries, 18" tubing,

CD software, NIST certificate of calibration and traceability, and user manual.

Challenger Kit

$80.00

Weekly

Call Us!

0.01 to

20 LPM

4146 Primary Flow Calibrator Kit

Compatible with all RAECO

Rents air sampling pumps.

4146 Calibrator

Kits include flow calibrator unit,

battery pack, zero filter, connector kit,

$80.00

Weekly

Call Us!

dampening chamber module, carrying case, six AA Alkaline batteries, tubing, battery pack lugs, carrying case, user guide, and NIST calibration certificate.

2.5 to 300

LPM

4046 Primary Flow Calibrator Kit

For calibrating Zefon

BioPump Plus.

Kits include calibrator, soft sided

carrying case, tubing, adapter, manual, inlet filter, calibration certificate, 6-AA batteries.

4046 Calibrator

$80.00

Weekly

Call Us!

Sensidyne Quad Tube Holder Kit

For use with Gilian 5000 and GilAir Plus pump kits.

Quad Tube Holder Kit

Kit includes tube holder housings,

housing ends, collar clips, hose barbs, couplings, wrench, tubing, tube

$50.00

Weekly

Call Us!

holder o-ring kit, in a clear storage box. Tube holders come in a variety of sizes, from Sensidyne standard to sizes for Kitagawa and Draeger tubes.

582

RAECO Rents LLC www.RAECORents.com [email protected]

Portable Gas Detectors

AP-20S Gas Detection Pump Kit

Kit includes Pump, three spare tube holders, lubricant, carrying bag, and manual. Detector tubes sold separately. See our website for a complete list.

AP-20S Pump Kit

$30.00

Weekly

Call Us!

Most Popular

Detector

Tubes

($69.00 per

Box of 10)

Don’t see the tubes you need?

Call us!

Gas/Vapor Range

Ammonia

0.5–30 %v

0.2–20 ppm

5–260 ppm

50–900 ppm

Carbon

Monoxide

Hydrogen

Sulfide

Nitrogen

Dioxide

0.1–20 %v

1–50 ppm

10–250 ppm

1–60 ppm

0.75–300 ppm

0.5–30 ppm 117SB

Cat #

105SH

105SD

105SC

105SB

106UH

106SC

106S

120SD

120SB

GasAlert Extreme Single Gas Monitors

Specify O2, CO, or HCN

GasAlert Extreme

Kit includes detector, concussion-proof hous-

ing, selected sensor (0-1000 ppm CO, 0-30% O2, or 0-30 ppm HCN), field replaceable battery, stainless steel alligator clip, calibration/test cap and hose, user manual, and quick reference card.

$75.00

Weekly

Call Us!

GasAlert Quattro Personal Four-Gas Detector

Replaces GasAlert Micro and MiniMax X4

GasAlert Quattro

Includes detector, sensors,

rechargeable battery pack, wall charger, calibration cap and tubing, reversible screwdriver, concussion-proof housing, stainless steel alligator clip, user manual, materials booklet, and technical reference guide.

$45.00

Daily

$100.00

Weekly

$6.00

Daily

$20.00

Weekly

BW Technologies

Connectivity Kit and Software

Infrared DataLink with BW Fleet Manager Software

Compatible with GasAlert Extreme and Quattro.

Call Us!

Connectivity Kit

Call Us!

Altair 5 Datalogging Multigas Detector

Altair 5 kit includes detector, sensors for

LEL, CO, O2, SO2, and H2S, integral pump,

10' sampling line, 1' probe, power supply/ charger, calibration cap and tubing, user manual CD, quick-start card, and carrying case.

MSA Altair 5 10094902

Call Us!

Call Us!

Call Us!

Solaris Four-Gas Combustible Gas Detector

Kit includes detector with sensors for

O2, CO, H2S, and %LEL, battery charger, charging station, calibration cap, tubing, two male fittings, infrared reader, pump probe, Solaris and card reader software, quick reference card, and manual on CD.

MSA Solaris

Call Us!

Call Us!

Call Us!

Rental Operations Office

135 Bernice Drive

Bensenville, IL 60106-3366

Rentals: 866-RENT-EHS

Fax: 815-464-8720

All portable and personal gas detectors are calibrated before shipping to you. Ready to use right out of the box.

Renting longer than a week? Ask us about cal gas for bump testing. (Hazmat shipping charges will apply.)

GasAlert Micro5 Multigas Monitors

Sensor

CO

O2

H2S

%LEL

CO2

Range

0–500 ppm

0–30.0%

0–500 ppm

0–100% LEL

0–5.0% v/v

0–50,000 ppm

0–5.0% v/v

0-100 ppm

0–150 ppm

Resolution

1.0 ppm

0.1%

1.0 ppm

1%

0.1%

50 ppm

0.01%

1.0 ppm

1.0 ppm

Model

5, 5IR, 5PID

5, 5IR, 5PID

5, 5IR, 5PID

5, 5IR, 5PID

5IR

NH3

SO2

5

5

Micro5 kit includes datalogging gas detector, sensors for CO, O2,

H2S and %LEL, rechargeable battery pack, cradle and charger,

GasAlert Micro5

Alkaline battery pack, motorized sampling pump, Fleet Manager II

$50.00

Daily

$150.00

Weekly

Call Us!

software, sample probe, diffusion cover, and 10-foot sample line, user manual, and carrying case.

GasAlert Micro5 w/SO2 GasAlert Micro5 w/NH3

$65.00

Daily

$175.00

Weekly

Call Us!

Monthly

$85.00

Daily

$190.00

Weekly

Call Us!

Monthly

Micro5 IR kit includes datalog-

ging detector, sensors for CO, O2,

H2S, %LEL, and CO2, rechargeable battery pack, cradle and, charger,

GasAlert Micro5 IR

Alkaline battery pack, pump module, diffusion cover, calibration

$65.00

Daily

$185.00

Weekly

Call Us!

cap and tubing, probe with tubing, screwdriver, Fleet Manager II software, user guides, manual, and carrying case.

GasAlert Micro5 PID Personal VOC Monitor

Sensor

CO

O2

H2S

%LEL

Range

0–500 ppm

0–30.0%

0–500 ppm

0–100% LEL

0–5.0% v/v

0–1000 ppm

Resolution

1.0 ppm

0.1%

1.0 ppm

1%

0.1%

1 ppm

Model

5, 5IR, 5PID

5, 5IR, 5PID

5, 5IR, 5PID

5, 5IR, 5PID

VOCs 5PID

Includes datalogging gas detec-

tor, sensors for CO, O2, H2S, %LEL, and VOCs, lithium polymer battery pack and cradle charger, motorized

GasAlert Micro5 PID

sampling pump and diffusion cover,

FleetxxManager II software, sample

$60.00

Daily

$165.00

Weekly

Call Us!

probe and 10-foot sample line, user manual, and carrying case.

RAECO Rents LLC www.RAECORents.com [email protected]

VOC Detection

Rental Operations Office

135 Bernice Drive

Bensenville, IL 60106-3366

PhoCheck Tiger Photoionization

Detector (PID) for VOCs

• Wide dynamic range ppb to 20,000 ppm for specific volatiles

• Accuracy to ±5% display reading ±1 digit

• LED, vibratory, and audible alarms — pre-programmed time-weighted average (TWA) and shortterm exposure limits (STEL) for 450 different gases

• Logs >120,000 data points including date and time stamp, 33 hours at one log per minute

• Intrinsically safe ATEX, IECEx, and cUL approvals

• Detects Benzene without the need for specific tubes in areas of

Benzene gas only; Requires selective pre-filter tubes for detecting

Benzene in other compounds

PhoCheck Tiger (10.6eV)

• Battery life up to 30 hours, and can be changed in hazardous areas

$95.00

Daily

$235.00

Weekly

Call Us!

Includes Detector with your choice of 10.6 eV or 11.7

eV Krypton PID lamp, rechargeable Li-Ion battery, battery charger and power adapter, rubber boot, carbon zero filter assembly and filter adapter, PTFE filter disc, removal tool miniPID stack, 60mm probe tube, PID lamp cleaning kit, lanyard, USB memory stick with software, USB cable, spare AA battery pack, user manual, and carrying case.

PhoCheck Tiger (11.7eV)

$110.00

Daily

$275.00

Weekly

Call Us!

PPM

PhoCheck+ 3000

Photoionization Detector (PID) for VOCs

Range: 0.1 ppm to 10,000 ppm

PhoCheck+ 3000

Includes 10.6 eV Krypton lamp, re-

moval tools, and cleaning kit, 100mm probe, 50 micron PTFE filter, four AA Alkaline batteries, charger, intrinsically

$90.00

Daily

$235.00

Weekly

Call Us!

safe protective cover, carbon canister for calibration, two Neoprene sleeves, Ion PC software, calibration kit sample, calibration adapter, calibration certificate, manual, and carrying case.

MiniRAE 3000 Photoionization Detector

Range: 0.1 to 15,000 ppm

MiniRAE 3000

Kit includes PGM-7320 monitor, wireless communication module built in, datalogging with ProRAE Studio Package for

Windows, charging/download adapter,

$95.00

Daily

$235.00

Weekly

Call Us!

RAE UV lamp, Flex-I-Probe TM , external filter, rubber boot, battery adapter, lamp-cleaning kit, tool kit, operation

CD-ROM and maintenance manual, and carrying case.

MicroFID Flame Ionization Detector for

EPA Method 21

Photovac MicroFID

Range: 0.1 to 50,000 ppm

VOCs and Alkanes

Ships with 8” Teflon sample probe, telescoping 6’ extension probe, fuel

$100.00

Daily

$300.00

Weekly

Call Us!

refill adapter, replacement Fluoropore membrane filters, multi-tool, carrying strap, printer cable kit, 15-hour rechargeable battery pack and 115 VAC charger, carrying case, and user manual. Call for calibration gas.

Rentals: 866-RENT-EHS

Fax: 815-464-8720

583

Refrigerant, Gas Leak and

Contaminant Detectors

Formaldemeter htV Airborne

Formaldehyde Meter

Kit includes meter, 10

phenol filters, thermometer, pen, 9V Alkaline battery, calibration standard, instruction manual, and carrying case.

Formaldemeter htV

$60.00

Daily

$160.00

Weekly

Call Us!

Formaldemeter htV–m

htV–m datalogging and

event logging model also

includes software and USB cable.

$175.00

Daily

$375.00

Weekly

Call Us!

For finding gases.

GasCheck 3000 Gas Leak Detector

This model is NOT intrinsically safe.

GasCheck 3000

Includes 10” probe, spare battery

clip, nozzle replacement tool, four AA Alkaline batteries, user

$95.00

Daily

$285.00

Weekly

manual, calibration certificate, and carrying case.

Call Us!

MVI Real-Time Mercury Vapor Monitor

Dual beam UV absorption sensor with ranges 0.1–200 and 1.0–1999 μg/m3

Kit Includes detector, PTFE probe

with moisture trap, charger, datalogging kit, zero (carbon) filter, spare water trap filter, user manual, and carrying case.

$140.00

Daily

MVI

$400.00

Weekly

Call Us!

IN USA Portable Ozone Spot Checker

Range: 0–1999 PPBv

Analog Output: 0 to 1.999 VDC

IN-AET-055-PA

Kit Includes ozone detector, built-in

micro pump, power cord, AA batteries, filters, USB cable, NIST certificate of traceability, user manual, and carrying case.

$70.00

Daily

$180.00

Weekly

Call Us!

Ready when you are!

Do you have the time, expertise, or staff availability it takes to properly maintain your portable industrial hygiene and safety monitoring instruments? Are you sure they’ll work when you need them to, or have all the accessories you need to perform your next test?

Before shipping instrumentation to you, a

RAECO Rents technician calibrates the unit and runs diagnostics to make sure your rental kit is in proper working order.

584

RAECO Rents LLC www.RAECORents.com [email protected]

Rental Operations Office

135 Bernice Drive

Bensenville, IL 60106-3366

Combustion Efficiency Analyzers

Which Combustion Analyzer Do You Need?

For O

2

330-2 LL

335

340

350

CO

NO

NO

2

SO

2

T/C

Draft &

Flow

Hydro-

Carbons

CO low

NO low

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Testo 340 Portable

Combustion Tuning Analyzer

Comes with analyzer, sensors for O2, CO,

NO, NO2, draft and flow, thermocouple probe, AC power adapter with Li-Ion battery, filters, high temp engine probe, user manual, and transport case.

340 Engine Kit

$145.00

Daily

$450.00

Weekly

Call Us!

Calculates CO2, efficiency, excess air, and mass emissions (with a Pitot tube).

330-2 LL Industrial Combustion Analyzer

Comes with sensors for O2, CO, NO, calculates NOx, 7’ hose, 12" probe,

Li-Ion battery, charger with cord, infrared printer with paper, carrying strap, standard case, USB cable, software, calibration certificate, and user manual.

330-2 LL Kit #2

$130.00

Daily

$350.00

Weekly

Call Us!

Testo 350 Advanced

Combustion Efficiency Analyzer

Includes sensors for CO, O2, NO, NO2, SO2, (CO low, NO low, and CxHy available on request); control unit, particulate filters, printer paper, carrying strap, 12" engine probe with 7' hose and

12" thermocouple probe with 7' or 16' cable, heat shield, RS232 cable, software, 16' remote control cable, calibration certificate, transport case, and user manual.

350 #3 Engine Kit 350 #3 Engine Kit + CxHy

Testo 335 Portable Flue Gas Analyzer

Includes sensors for O2, CO, and NO, calculates NOx, Type

K thermocouple, 12” probe,

7-foot Teflon®-lined hose, infra-

335 NOx Kit

red printer with paper, power adapter and charger, two Li-Ion

$125.00

Daily

$350.00

Weekly

Call Us!

batteries, filters, Easy Emission software, USB cable, case, calibration certificate, and manual.

$210.00

Daily

$525.00

Weekly

Call Us!

$250.00

Daily

$650.00

Weekly

Call Us!

Learn more at RaecoRents.com

Specs, manuals, quick-start guides, software, and free training videos available all day, every day!

EasyEmissions Software

• Realtime analyzer control through your

PC, showing tabular, graphical, and picture box results

• Calculates min/max, and mean values

• Programmable logging intervals

• Custom formulas for report calculations

• Data transfer to Excel® or Adobe® PDF

• Free with all compatible Testo rentals

Visual Inspection and Non-Destructive Testing

Mark 10 Digital Force Gauge

Kit includes instrument, chisel, cone, V-grove, screw and hook, flat, extension rod, universal voltage

AC adapter, battery, single handle,

$55.00

Daily

$135.00

Weekly

Call Us!

two-handle base, three push attachments, USB cable, resource CD with USB driver, MESURgauge demo software and PDF user manual, printed quick-start guide, NIST traceable calibration certificate, and carrying case.

SV106 Human Vibration Meter/Analyzer

Kit includes SV106 meter, seat accelerometer, hand-arm adapter, 4

AA Alkaline batteries and spares, USB cable, software CD, carrying case, NIST calibration certificate, and user manual.

$130.00

Daily

$390.00

Weekly

Call Us!

Vibration Measuring Accessories

SV105 Hand Arm Vibration Measurement

SV38V Whole Body Vibration Pad

SV207A-SO Building Vibration Measurement

D W M

$30.00 $90.00 Call

35.00 105.00 Call

110.00 330.00 Call

880-3 Thermal Imager/Digital Camera

Comes with 1 GB SD card, black protective lens, lens cap, lens cleaning cloth, USB cable, rechargeable battery, Allen wrench,

$130.00

Daily

$350.00

Weekly

Call Us!

wrist strap, tripod mounting plate, software, power supply/charger, user manual, and carrying case.

318-V Video PRO Confined Space

Digital Inspection Tool

318-V 42" Scope

Kit includes digital inspection scope, mirror tip, magnetic tip, carrying case, four AA batteries and manual.

$40.00

Weekly

Call Us!

RAECO Rents LLC www.RAECORents.com [email protected]

Rental Operations Office

135 Bernice Drive

Bensenville, IL 60106-3366

Rentals: 866-RENT-EHS

Fax: 815-464-8720

585

Sound Level Meters and Noise Dosimeters

SoundPro DL Datalogging Sound Level Meters

Type 1 and Type 2 available

Includes meter, QC-10

calibrator, 1/3 octave band analyzer, wrist strap, windscreen, USB cable,

128MB SD card, microphone,

QuestSuite Pro II software

CD, 9V battery, four AA

Alkaline batteries, AC power adapter, user manual, calibrator manual, calibration certificate, and carrying case.

(Type 1) SP-DL-1-1/3-AC3

$80.00

Daily

$240.00

Weekly

Call Us!

(Type 2) SP-DL-2-1/3-10

$80.00

Daily

$240.00

Weekly

Call Us!

Optional Mic for 3M/Quest Sound Pro Type 1 Sound Level Meter QE4130 -

Free field, Class/Type 1, 0.5” diameter (0.52"), condenser (200V must be set to “On”).

Use for general, higher level, free-field measurements.

Edge Intrinsically Safe Personal Noise Dosimeters

Now with three virtual dosimeters!

Single rental includes one dosim-

eter, one-unit EdgeDock docking station with power supply, USB cable, windscreen, 1/4" microphone,

Allen wrench, spare wind screen, user manual, software CD, QC-10 calibrator and adapter, calibration certificate, and carrying case.

eg5-D Single Dosimeter

$70.00

Daily

$160.00

Weekly

Call Us!

5eg5-D-10 Five-Pack

Five-pack includes five each: dosimeters, wind-

screen assemblies, 1/4" microphones, calibration certificates, plus one each: manual, software CD,

QC-10 calibrator and adapter, five-unit EdgeDock

$240.00

Daily

$670.00

Weekly

Call Us!

docking station with power supply, Allen wrench, spare wind screen, USB cable, and carrying case.

Outdoor Enclosure Kit for SoundPro DL

Run outdoor sound level tests in any weather!

SP-OMS Enclosure Kit

Includes weather-resistant

carrying case, microphone

$75.00

Daily

$185.00

Weekly

Call Us!

mast, windscreen, cable, rechargeable battery packs, AC charger for batteries, adapters, and user manual.

Can be configured for remote monitoring using

Netronix Thiamis ICU820 to send alarms.

Need multiple kits? Call 866-736-8347 for quantity price discounts.

2200 Type 2 Integrating Sound Level Meter

Kit includes meter, windscreen,

adapter, calibrator, 50' remote cable with microphone, manual, calibration certificate, and storage case.

This is NOT a datalogging unit.

Quest 2200R-10

$60.00

Daily

$125.00

Weekly

Call Us!

NoisePro DLX Type 2 Noise Dosimeters

NP-DLX kit includes dosi meter,

mic and cord, wind screen, calibrator and adapter, clothing clip, QC-10 calibrator, IR/RS-232 PC interface cable, QuestSuite® II software, manual, training/demo CD, USB cable, calibration certificate, and carrying case.

NP-DLX-CBL Dosimeter

$45.00

Daily

$135.00

Weekly

Call Us!

5NP-DLX10QSPII Five-Pack

Five-pack includes five each: NoisePro DLX dosim-

eters, microphones with cords, windscreens, clothing clips, plus one each: calibrator adapter, PC interface cable, QC-10 calibrator, watertight case, QuestSuite®

$175.00

Daily

II software CD, USB cable, manual, and calibration certificate.

$525.00

Weekly

Call Us!

QC-10 Sound Calibrator (114 dB @ 1000 Hz)

Free with meter rentals!

Kit includes calibrator, 9V

transistor battery, calibration certificate, and user manual.

Mic adapter not included.

$20.00

Daily

$50.00

Weekly

Call Us!

2900-UL-30010 Integrating Sound Level Meter

Includes meter, mic, OB-300

octave band filter, windscreen, wrist strap, calibrator and adapter, serial interface cable, QuestSuite software, calibration certificate, and carrying case.

Quest 2900-UL-30010

$50.00

Daily

$125.00

Weekly

Call Us!

All rentals for 3M Quest products include your choice of Q uest s uite

P ro ii or 3M Detection Management (DMS)

30-day trial software!

Download the latest versions today at RaecoRents.com

Radiation Exposure Testing

ELT-400 Magnetic Field

Exposure Level Tester

Range: 1 Hz to 400 KHz

Narda ELT-400

Kit includes instrument, probe,

probe extension cable, serial data cable, analog interface cable for use with oscilloscope or spectrum

$145.00

Daily

analyzer, power adapter, calibration certificate, user manual, and carrying case.

$475.00

Weekly

Call Us!

SE Inspector Digital Radiation Alert Detector

Measurement Range: 0.001 (1 µR)–100 mR/hr, 0–350000 CPM,

0.01–1000 µSv/ hr, 0–5000 CPS

SE Inspector EXP: Choose built-in detector or external pancake probe.

SE Inspector SE Inspector Exp

Includes instrument,

9V battery, user manual, and soft carrying case.

$300.00

Weekly

Call Us!

$300.00

Weekly

Call Us!

586

RAECO Rents LLC www.RAECORents.com [email protected]

Respirator Fit Testers

PortaCount® Pro and Pro+ Quantitative

Respirator Fit Testers

Rental Operations Office

135 Bernice Drive

Bensenville, IL 60106-3366

Rentals: 866-RENT-EHS

Fax: 815-464-8720

Mask Adapters and Fit Testing Supplies

Popular mask adapter kits available free with rental.

Learn how to use

PortaCount Pro systems.

Free video training at

RaecoRents.com/train/

Which model do you need?

PortaCount Pro 8030

For disposable filtering facepieces

Series 100, 99, P3, and HEPA masks, half and full-face masks, gas masks,

PAPR, and SCBA mask fit testing.

$150.00

Daily

$450.00

Weekly

Call Us!

PortaCount Pro+ 8038

Fit test ANY tight-fitting respirator, plus N95, P2, and P1 disposables;

OSHA-compliant for all respirators.

Combines functions of TSI 8020 and 8095.

$200.00

Daily

$600.00

Weekly

Call Us!

TSI 8030 kit ships with AC adapter, alcohol cartridge, alcohol fill capsule, storage cap, two zero check filters, alcohol supplies, 3/16" and 1/4" hose adapters, two spare alcohol wicks, carrying case, FitPro software and tutorial CDs, 1GB flash memory drive, USB cable, user manual, and calibration certificate.

TSI 8038 kit ships with AC adapter, alcohol cartridge, alcohol fill capsule, storage cap, two zero check filters, alcohol supplies, 3/16" and 1/4" hose adapters, two spare alcohol wicks, 25 sampling probes, probe insertion tool, neck strap, carrying case, FitPro software and tutorial CDs, 1GB flash memory drive, USB cable, user manual, and calibration certificate.

Testing in clean environments?

Rent a TSI 8026 particle generator, $50.00/day, $160.00/week.

Don’t forget your N95 probes or mask adapter kits.

Don’t forget your respirator adapter kit!

Mask adapters are required for fit testing, but are not included with any PortaCount rental units. If you don’t have an adapter for your model respirator mask, popular models are available free with a test kit rental (or for a small fee when rented separately).

Adapter kits generally include the adapter that connects your mask to the fit tester, P100 HEPA filters, and disposable components. If you need additional test supplies, buy the refill kit that matches your adapter kit. For-sale kits have enough supplies for 200 tests. Rental kits include enough supplies for 25 tests.

Adapter to Fit...

Refill

Kit

Catalog

Number Price

3M masks, Including those with detachable filters 800553 8025-16 $310.00

Avon masks with drink tube (Also fits US M50) 801633 8025-AVON 155.00

Dräger Combitox Nova RD91, Cirrus RD91 8025-24 220.00

Dräger masks, 40mm filter threads or snap-in connectors

Interspiro Spiromatic and Spirolite SCBA facepiece

Interspiro Spiromatic S and S4 SCBA facepiece

MSA Advantage 1000, Millennium;

Also 3M FR-M40, US Mil MCU-2/P, M40

MSA Millennium, US Mil M40/MCU-2P (Adapter

Only)

MSA Advantage respirators with bayonet filters

MSA Comfo, Advantage half or full-face masks

MSA Ultra Elite, Advantage 3100 (40mm screw-in)

MSA Ultra Elite, Quarter-Turn MMR (Not Firehawk)

MSA UltraView (incl. SCBA with screw-in connection, Ultra Twin, Phalanx)

MSA UltraView with Quarter-Turn MMR

MSA Ultra Elite Firehawk, Blackhawk, Airhawk Push to Connect

North masks (5400, 5500, 7600-7800, 80004,

800045, 85400A, 85500A, 800 series)

Protector/Sabre Phantom PAPR, 48mm thread

Scott full-face AV-2000, AV-3000, Scott-O-Vista, 65

Survivair air purifying masks (Includes 2000, Blue

1, Low Mtce, 4000, 20/20)

Survivair positive-pressure SCBA masks, Pantherstyle MMR (Classic, 20/20, OPTI-Fit)

800553

800785

800785

800785

800553

800553

800553

800553

8025-26

8025-21

8025-21S

8025-29

1081379

8025-30

8025-14

8025-22

165.00

360.00

320.00

8025-22Q 360.00

8025-15

8025-15Q

8025-31

8025-17

8025-28

8025-20

8025-12

8025-13

495.00

665.00

730.00

135.00

55.00

220.00

260.00

285.00

285.00

215.00

205.00

225.00

435.00

US Safety, all masks

Wilson F-series facepieces, 1" screw-on filters

Wilson T-series bayonet-type masks, GT-series small diam screw-on connections

800553

800553

800553

8025-25

8025-23

8025-19

200.00

385.00

270.00

Generic 40mm facepieces 800553 8025-CEN 220.00

Gas masks with standard US military drink tubes 801633 8025-USMIL 200.00

Accessories and Consumables

Filtering Facepieces Probe Kit (500 probes and tool set)

Refill Kit for 8025-N95 (500 probes and push-nuts)

Refill Kit #1 (50' tubing, 200 clips, 200 suction cups)

Refill Kit #2 (50' tubing, 200 clips, 200 suction cups)

Refill Kit #3 (50' tubing, 200 clips, 200 suction cups)

Particle generator for PortaCount Pro and Pro+

Salt tablets for particle generator (Bag of 100)

8025-N95

8025-N95R

800553

800785

801633

8026

803011

190.00

130.00

120.00

120.00

135.00

840.00

40.00

Reagent-grade alcohol (Case of 16 30ml bottles)

Zero check HEPA filter for PortaCount Pro and Pro+

10-Pack alcohol wicks, screens (For TSI 8030 and 8038)

Sample hose kit, 3x5' twin tubes, 10 adapters ea: 3/16", 1/4"

Twin tube, one 5' blue/clear tube

18" Pendant twin tubes for N95 testing, pack of five

8016

803X-ZFLTR

8033

8017

800197

801501

115.00

35.00

125.00

115.00

25.00

45.00

TSI PortaCount® Pro and Pro+ Honeywell XNX

New Best-in-Class Quantitative

Respirator Fit Testing Systems

• Measures fit factors >10,000

• OSHA-compliant for tight-fitting respirators (Pro) or for both tight-fitting respirators and disposable masks (Pro+)

• Stand-alone operation with digital color touchscreen

• Connect to a PC to add functionality — automate testing, generate reports, and print ID cards

Units available for sale or short-term rental.

One Gas Detection Transmitter Fits All!

• Detects toxic gases, combustibles, and oxygen

• Use with Honeywell electrochemical cells, catalytic bead sensors, infrared cell, point IR, and open path IR detectors

• Explosion proof and intrinsically safe operation with UL,

FM, CSA, and ATEX approvals — Now available for SIL2

• Full diagnostics, including sensor safety checks at startup

• 4–20 mA with HART® output standard

• Backlit, easy-to-read local display

Learn more inside.

866-RENT-EHS

866-736-8347

Portable industrial hygiene instruments

• Air monitoring pumps and calibration tools

• IAQ and ventilation testing instruments

• Personal and area particulate monitoring instruments

• Sound and noise level monitors

• Non-contact thermal and optical testing instruments

Portable safety and gas detection instruments

• Quantitative respirator fit testing systems

• Portable emissions monitors and combustion analyzers

• Gas detection instruments for toxics, combustibles, and oxygen

• Heat stress monitors

Rent online at www.RAECO.com and save 5% automatically on your daily, weekly, or monthly rentals!

No forms to fill out. No codes to remember.

Just click and save!

Not sure exactly what you need? Have a special requirement?

Call our rental team at 866-RENT-EHS (that’s 866-736-8347)

Reach us any way you want!

800-852-9795 www.RAECO.com [email protected]

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project