Maxsys PC4164-433 Installation Manual
Advertisement
Advertisement
FCC COMPLIANCE STATEMENT
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY DIGITAL SECURITY
CONTROLS LTD. COULD VOID YOUR AUTHORITY TO USE THIS EQUIPMENT.
•
•
•
•
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart “B” of Part
15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient the receiving antenna
Relocate the alarm control with respect to the receiver
Move the alarm control away from the receiver
Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve
Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office,
Washington, D.C. 20402, Stock # 004-000-00345-4.
PC4164-433 v3.0
• Installation Manual
WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read.
®
©2002 Digital Security Controls Ltd.
Direct all comments and suggestions concerning DSC publications to [email protected]
Printed in Canada 29034504 R002
(Outside of North America, please contact your authorized DSC distributor for technical support)
This PC4164-433 V3.0 receiver version is currently supported by all PC4010/PC4020/P-16128 V3.x DLS-3 downloading files.
WARNING
Please Read Carefully
Note to Installers
This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system.
System Failures
This system has been carefully designed to be as effective as possible.
There are circumstances, however, involving fire, burglary, or other types of emergencies where it may not provide protection. Any alarm system of any type may be compromised deliberately or may fail to operate as expected for a variety of reasons. Some but not all of these reasons may be:
■
Inadequate Installation
A security system must be installed properly in order to provide adequate protection. Every installation should be evaluated by a security professional to ensure that all access points and areas are covered. Locks and latches on windows and doors must be secure and operate as intended. Windows, doors, walls, ceilings and other building materials must be of sufficient strength and construction to provide the level of protection expected. A reevaluation must be done during and after any construction activity. An evaluation by the fire and/or police department is highly recommended if this service is available.
■
Criminal Knowledge
This system contains security features which were known to be effective at the time of manufacture. It is possible for persons with criminal intent to develop techniques which reduce the effectiveness of these features. It is important that a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected.
■
Access by Intruders
Intruders may enter through an unprotected access point, circumvent a sensing device, evade detection by moving through an area of insufficient coverage, disconnect a warning device, or interfere with or prevent the proper operation of the system.
■
Power Failure
Control units, intrusion detectors, smoke detectors and many other security devices require an adequate power supply for proper operation. If a device operates from batteries, it is possible for the batteries to fail. Even if the batteries have not failed, they must be charged, in good condition and installed correctly. If a device operates only by
AC power, any interruption, however brief, will render that device inoperative while it does not have power. Power interruptions of any length are often accompanied by voltage fluctuations which may damage electronic equipment such as a security system. After a power interruption has occurred, immediately conduct a complete system test to ensure that the system operates as intended.
■
Failure of Replaceable Batteries
This system’s wireless transmitters have been designed to provide several years of battery life under normal conditions. The expected battery life is a function of the device environment, usage and type.
Ambient conditions such as high humidity, high or low temperatures, or large temperature fluctuations may reduce the expected battery life.
While each transmitting device has a low battery monitor which identifies when the batteries need to be replaced, this monitor may fail to operate as expected. Regular testing and maintenance will keep the system in good operating condition.
■
Compromise of Radio Frequency (Wireless) Devices
Signals may not reach the receiver under all circumstances which could include metal objects placed on or near the radio path or deliberate jamming or other inadvertent radio signal interference.
■
System Users
A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary physical disability, inability to reach the device in time, or unfamiliarity with the correct operation. It is important that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm.
■
Smoke Detectors occupants of a fire for a number of reasons, some of which follow.
The smoke detectors may have been improperly installed or positioned. Smoke may not be able to reach the smoke detectors, such as when the fire is in a chimney, walls or roofs, or on the other side of closed doors. Smoke detectors may not detect smoke from fires on another level of the residence or building.
Every fire is different in the amount of smoke produced and the rate of burning. Smoke detectors cannot sense all types of fires equally well. Smoke detectors may not provide timely warning of fires caused by carelessness or safety hazards such as smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches or arson.
Even if the smoke detector operates as intended, there may be circumstances when there is insufficient warning to allow all occupants to escape in time to avoid injury or death.
■
Motion Detectors
Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions. They cannot discriminate between intruders and intended occupants. Motion detectors do not provide volumetric area protection. They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams. They cannot detect motion which occurs behind walls, ceilings, floor, closed doors, glass partitions, glass doors or windows. Any type of tampering whether intentional or unintentional such as masking, painting, or spraying of any material on the lenses, mirrors, windows or any other part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature. However their effectiveness can be reduced when the ambient temperature rises near or above body temperature or if there are intentional or unintentional sources of heat in or near the detection area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on.
■
Warning Devices
Warning devices such as sirens, bells, horns, or strobes may not warn people or waken someone sleeping if there is an intervening wall or door. If warning devices are located on a different level of the residence or premise, then it is less likely that the occupants will be alerted or awakened. Audible warning devices may be interfered with by other noise sources such as stereos, radios, televisions, air conditioners or other appliances, or passing traffic. Audible warning devices, however loud, may not be heard by a hearing-impaired person.
■
Telephone Lines
If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods of time. Also an intruder may cut the telephone line or defeat its operation by more sophisticated means which may be difficult to detect.
■
Insufficient Time
There may be circumstances when the system will operate as intended, yet the occupants will not be protected from the emergency due to their inability to respond to the warnings in a timely manner. If the system is monitored, the response may not occur in time to protect the occupants or their belongings.
■
Component Failure
Although every effort has been made to make this system as reliable as possible, the system may fail to function as intended due to the failure of a component.
■
Inadequate Testing
Most problems that would prevent an alarm system from operating as intended can be found by regular testing and maintenance. The complete system should be tested weekly and immediately after a breakin, an attempted break-in, a fire, a storm, an earthquake, an accident, or any kind of construction activity inside or outside the premises.
The testing should include all sensing devices, keypads, consoles, alarm indicating devices and any other operational devices that are part of the system.
■
Security and Insurance
Regardless of its capabilities, an alarm system is not a substitute for property or life insurance. An alarm system also is not a substitute for property owners, renters, or other occupants to act prudently to prevent or minimize the harmful effects of an emergency situation.
LIMITED WARRANTY
Digital Security Controls Ltd. warrants the original purchaser that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use. During the warranty period, Digital Security
Controls Ltd. shall, at its option, repair or replace any defective product upon return of the product to its factory, at no charge for labour and materials. Any replacement and/or repaired parts are warranted for the remainder of the original warranty or ninety
(90) days, whichever is longer. The original purchaser must promptly notify Digital Security Controls Ltd. in writing that there is defect in material or workmanship, such written notice to be received in all events prior to expiration of the warranty period. There is absolutely no warranty on software and all software products are sold as a user license under the terms of the software license agreement included with the product. The
Customer assumes all responsibility for the proper selection, installation, operation and maintenance of any products purchased from DSC. Custom products are only warranted to the extent that they do not function upon delivery. In such cases,
DSC can replace or credit at its option.
International Warranty
The warranty for international customers is the same as for any customer within Canada and the United States, with the exception that Digital Security Controls Ltd. shall not be responsible for any customs fees, taxes, or VAT that may be due.
Warranty Procedure
To obtain service under this warranty, please return the item(s) in question to the point of purchase. All authorized distributors and dealers have a warranty program. Anyone returning goods to Digital Security Controls Ltd. must first obtain an authorization number. Digital Security Controls Ltd. will not accept any shipment whatsoever for which prior authorization has not been obtained.
Conditions to Void Warranty
This warranty applies only to defects in parts and workmanship relating to normal use. It does not cover:
• damage incurred in shipping or handling;
• damage caused by disaster such as fire, flood, wind, earthquake or lightning;
• damage due to causes beyond the control of Digital Security
Controls Ltd. such as excessive voltage, mechanical shock or water damage;
• damage caused by unauthorized attachment, alterations, modifications or foreign objects;
• damage caused by peripherals (unless such peripherals were supplied by Digital Security Controls Ltd.);
• defects caused by failure to provide a suitable installation environment for the products;
• damage caused by use of the products for purposes other than those for which it was designed;
• damage from improper maintenance;
• damage arising out of any other abuse, mishandling or improper application of the products.
Items Not Covered by Warranty
In addition to the items which void the Warranty, the following items shall not be covered by Warranty: (i) freight cost to the repair centre; (ii) products which are not identified with DSC's product label and lot number or serial number; (iii) products disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection or testing to verify any warranty claim. Access cards or tags returned for replacement under warranty will be credited or replaced at
DSC's option. Products not covered by this warranty, or otherwise out of warranty due to age, misuse, or damage shall be evaluated, and a repair estimate shall be provided. No repair work will be performed until a valid purchase order is received from the Customer and a Return Merchandise Authorisation number (RMA) is issued by DSC's Customer Service.
Digital Security Controls Ltd.’s liability for failure to repair the product under this warranty after a reasonable number of attempts will be limited to a replacement of the product, as the exclusive remedy for breach of warranty. Under no circumstances shall
Digital Security Controls Ltd. be liable for any special, incidental, or consequential damages based upon breach of warranty, breach of contract, negligence, strict liability, or any other legal theory.
Such damages include, but are not limited to, loss of profits, loss of the product or any associated equipment, cost of capital, cost of substitute or replacement equipment, facilities or services, down time, purchaser’s time, the claims of third parties, including customers, and injury to property. The laws of some jurisdictions limit or do not allow the disclaimer of consequential damages.
If the laws of such a jurisdiction apply to any claim by or against
DSC, the limitations and disclaimers contained here shall be to the greatest extent permitted by law. Some states do not allow the exclusion or limitation of incidental or consequential damages, so that the above may not apply to you.
Disclaimer of Warranties
This warranty contains the entire warranty and shall be in lieu of any and all other warranties, whether expressed or implied
(including all implied warranties of merchantability or fitness for a particular purpose) and of all other obligations or liabilities on the part of Digital Security Controls Ltd. Digital
Security Controls Ltd. neither assumes responsibility for nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product.
This disclaimer of warranties and limited warranty are governed by the laws of the province of Ontario, Canada.
WARNING: Digital Security Controls Ltd. recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected.
Out of Warranty Repairs
Digital Security Controls Ltd. will at its option repair or replace out-of-warranty products which are returned to its factory according to the following conditions. Anyone returning goods to Digital Security Controls Ltd. must first obtain an authorization number. Digital Security Controls Ltd. will not accept any shipment whatsoever for which prior authorization has not been obtained.
Products which Digital Security Controls Ltd. determines to be repairable will be repaired and returned. A set fee which Digital
Security Controls Ltd. has predetermined and which may be revised from time to time, will be charged for each unit repaired.
Products which Digital Security Controls Ltd. determines not to be repairable will be replaced by the nearest equivalent product available at that time. The current market price of the replacement product will be charged for each replacement unit.
Index
A
Add device 7 wireless key 8
Antenna 4
B
Batteries replacing 15 type 4
Buttons programming 8
C
Connect
Combus 5
PC4164-433 5
D
Deleting devices 12
Devices adding 7 deleting 12 replacing 12
Distance from control panel 4
E
Electronic serial number 7
Enroll device 7 module 6 wireless key 8
ESN.
See Electronic serial number
F
Frequency 4
L
Low battery devices 15
M
Motion detector test 10
Mount devices 11
PC4164-433 11
N
Number serial 7 slot 8
Numbers reference 3
P
Partition programming for buttons 9
Placement test 10
Power 5
Problems 16
Programming how to 3
R
Reference numbers 3
Remove devices 12
Replace devices 12
S
Serial numbers 7
Slot number wireless key 8
Supervision 14
T
Testing door/window contact 10 motion detector 10 wireless key 11
Trouble conditions 14
Troubleshooting 16
W
Wireless key enrolling 8 identifying 8 programming 8 reporting 8
Z
Zone adding 7
Important Programming Notes
• The Wireless Device Fail Time (Section [001307]) in the panel is set to
3:00 hours by default. For a North American 433MHz system, the recommended setting for Device Fail Time is 24:00 hours. (08:00 hours minimum).
• The Wireless Device Fail Time (Section [001307]) in the panel is set to
3:00 hours by default. For a 433MHz European system, the recommended setting for the Device Fail Time is 02:30 hours to meet regulations.
• RF Jam Detect (Section [000200]) in the panel is disabled by default.
• This PC4164-433 V3.0 receiver version is currently supported by all
PC4010/PC4020/P-16128 V3.x DLS-3 downloading files.
https://www.e-camere.ro/alarma-antiefractie/module/DSC/PC-4164/
20
Table of Contents
P R O G R A M M I N G W O R K S H E E T S
[001306] Device Supervision
NOTE: Wireless Keys are NOT supervised.
Default = ON
1.1
Before You Begin .......................................................................................... 3
1.2
How to Use This Manual ........................................................................... 3
1.3
PC4164-433 Specifications .......................................................................... 4
1.4
Wireless Devices .......................................................................................... 4
2.1
Unpack the PC4164-433 Receiver .............................................................. 5
2.2
Install the Antennas .................................................................................... 5
2.3
Find a Mounting Location for the PC4164-433 ....................................... 5
2.4
Connecting the PC4164-433 ....................................................................... 5
2.5
Enroll the PC4164-433 ................................................................................. 6
Enr oll & Pr ogram W ir eless Devices
3.1
A Note about Electronic Serial Numbers (ESN) ..................................... 7
3.2
Enrolling Wireless Detectors ...................................................................... 7
3.3
Enrolling and Programming Wireless Keys ............................................ 8
T esting & Mounting Devices
4.1
Test the Placement of the Wireless Detectors ....................................... 10
4.2
Test Wireless Key Reception ..................................................................... 11
4.3
Mount the PC4164-433 Receiver and Wireless Devices ........................ 11
5.1
Replacing Devices ..................................................................................... 12
5.2
Deleting Devices ........................................................................................ 12
5.3
Deleting Device Serial Numbers ............................................................. 13
5.4
Deleting a PC4164-433 Module ............................................................... 13
6.1
Device Fail Time ........................................................................................ 14
6.2
Trouble Conditions .................................................................................... 14
Zone Supervision
No.
ON/OFF l_____l_____l_____l l________l l_____l_____l_____l l________l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l
Zone Supervision
No.
ON/OFF l_____l_____l_____l l________l l_____l_____l_____l l________l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l
Zone Supervision
No.
ON/OFF l_____l_____l_____l l________l l_____l_____l_____l l________l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l l________l
Pr ogramming W orksheets
Device Fail Time (see section 6.1)
[001307] Default = 0300 (valid entries 01:00 - 23:59)
NOTE: In North America program 24:00; in Europe program to 02:30.
l_______l_______l_______l_______l
This device complies with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
4164 Low Battery Transmission Delay (see section 6.2)
[00040211] Default = 007 (000-255 days) l_______l_______l_______l
Ce dispositif satisfait aux exigences d’Industrie Canada, prescrites dans le document CNR-210.
RF Jam Detect System Option* (see section 6.2)
son utilisation est autorisée seulement aux conditions suivantes: (1) il ne doit pas produire de https://www.e-camere.ro/alarma-antiefractie/module/DSC/PC-4164/ reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.
[000200] Default = OFF l________l
* This option must be turned ON for UL/ULC/CE installations.
19
P R O G R A M M I N G W O R K S H E E T S
Introduction
S E C T I O N 1
WLS9X9 Wireless Key Options (see section 3.3)
[001300] Enroll Device Default = 000000
Wireless Serial Wireless
Key No.
01
No.
Key No.
09
Serial
No.
The PC4164-433 is a wireless signal receiver for use with Maxsys PC4010 and PC4020/
P-16128 v3.X panels. The PC4164-433 receives signals from WLS9XX 433MHz wireless devices.
02
03
04 l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l
10
11
12 l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l
Install up to eight PC4164-433 v3.0 r eceivers: v3.2 or higher system, you can enroll up to eight PC4164-433 wireless receivers. This will give you a greater range in which to install wireless devices. It will also allow you to install backup wireless receivers with overlapping ranges, to provide increased security for the wireless zones on the system.
05
06 l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l
13
14 l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l
NOTE: If you ar e installing a PC4010/ PC only enr oll one PC4164-433 v3.0 module.
4020 /P-16128 v3.0 or 3.1 system, you can
07 l_____l_____l_____l_____l_____l_____l
15 l_____l_____l_____l_____l_____l_____l
1.1 Before You Begin
08
[001304] l_____l_____l_____l_____l_____l_____l
16
Wireless key Functions Default = 00 l_____l_____l_____l_____l_____l_____l
Key Button Partition Button Partition Button Partition Button Partition
No.
1 No.
2 No.
3 No.
4 No.
01 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l
This manual describes how to install, program and maintain the PC4164-433 v3.0 on a
PC4010/PC4020/P-16128 Security System. You should have completed the following steps in your PC4010/PC4020/P-16128 installation, before you install the PC4164-433 module:
1.
Plan the installation and wiring of the PC4010/PC4020/P-16128 system (see PC4010/
PC4020/P-16128 Installation Manual , Section 2: Installation and Wiring)
02 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l
2.
Install the control panel and at least one keypad to use for programming (see PC4010/
PC4020/P-16128 Installation Manual , Section 3: How to Program)
03
04 l_____l_____l l_____l_____l l_________l l_________l l_____l_____l l_____l_____l l_________l l_________l l_____l_____l l_____l_____l l_________l l_________l l_____l_____l l_____l_____l l_________l l_________l
3.
Install and enroll all hardwired zone expander modules (PC4108 or PC4116) (see
PC4010/PC4020/P-16128 Installation Manual , Section 4: Module Enrollment).
05
06
07 l_____l_____l l_____l_____l l_____l_____l l_________l l_________l l_________l l_____l_____l l_____l_____l l_____l_____l l_________l l_________l l_________l l_____l_____l l_____l_____l l_____l_____l l_________l l_________l l_________l l_____l_____l l_____l_____l l_____l_____l l_________l l_________l l_________l
You can program the PC4164-433 from a PC4010/PC4020/P-16128 system LCD keypad or using DSC’s downloading software (DLS-3 or higher), see the PC4010/PC4020/P-
16128 Installation Manual , Section 3 “How to Program”.
08 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l
1.2 How to Use This Manual
09 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l
To install and set up the PC4164-433 and wireless devices, follow these steps:
10 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l 1.
Enroll and temporarily mount the PC4164-433 module (see Section 2 )
11 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l 2.
Enroll and program wireless devices using zones and wireless keys (see Section 3 )
12 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l 3.
Complete zone and other programming on the system (see Sections 4 and 5)
13 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l 4.
Test the placement of all the wireless devices (see Section 6)
14 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l 5.
Permanently mount the PC4164-433 receiver and wireless devices (see Section 6)
15 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l
To replace or delete wireless devices already enrolled, see Section 4.
16 l_____l_____l l_________l
*Enter partition number 1-8 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l
For additional information on wireless motion detectors and wireless keys, see Sections
7 and 8.
W ir eless Key Function Key Options
00
01
02
Null Key
Stay Arm
Away Arm
16
17
18
Fire Alarm
Auxiliary Alarm
Panic Alarm
For help with troubleshooting, see Section 9.
Record the zone or slot and serial numbers of all wireless devices, and other programming in the Programming Worksheets section at the end of the manual.
03 No-Entry Arm 19 Disarm (Off)
04 Chime On/Off 20 Quick Bypass
05
06
System Test 21
Quick Exit 22
Music Input
T-code
07 Arm Interior 23 Zone Control
All programming sections in this manual are referred to by reference number. A detailed description of PC4010/PC4020/P-16128 programming is in the PC4010/PC4020/P-16128
Installation Manual , section 3 “How to Program.”
08-15 [ ✱ ][7] Command Outputs 1-8
PC4010/PC4020/P-16128 Programming
18 3
I N T R O D U C T I O N
To program using reference numbers, enter Installer’s programming ([ ✱ ][8][Installer’s
Code]). Press and hold the [A]uxiliary key until the keypad displays the following message:
“Enter Ref # then ✱ .”
Enter the reference number found in the Programming Worksheets for the section you wish to program, then press the [ ✱ ] key. The display will immediately go to the programming item you have selected.
1.3 PC4164-433 Specifications
• Up to eight PC4164-433 receivers can be installed per PC4020/P-16128 v3.2 or higher system; one PC4164-433 receiver can be installed per PC4010/PC4020/P-16128 v3.1
and v3.0 system
• Nominal current draw of 80mA
• Frequency: 433 MHz
• Receives signals from up to 56 wireless zones on a PC4010 v3.0 and later, and up to
64 wireless zones on a PC4020/P-16128 v3.0 and later
• Antenna - diversity design for enhanced performance
• Programmable supervisory window, programmable hours from 01:00 to 23:59
• Location
- can be wired up to 750 ft. / 230 m from the main panel with 22 gauge wire
- connects to Combus
- for longer wire runs, thicker gauge wire must be used.
1.4 Wireless Devices
Please refer to the Installation Instruction sheets of the following devices for more information.
The PC4164-433 v3.0 can receive signals from the following devices:
• (P)WLS904-433/(P)WLS904P(L)-433 Motion Detector
• WLS906-433 Smoke Detector
• (P)WLS907-433/(P)WLS925L-433/WLS935L-433 Universal Transmitter
• (P)WLS907T-433 Wireless Low Temperature Sensor
• WLS909-433/WLS919-433 Wireless Key (up to 16)
• WLS912L-433 Glassbreak Detector
• (P)WLS914-433 Pet Immune Motion Detector (North American Market only)
4
Programming Worksheets
S E C T I O N 4
[001300] Enroll Wireless Detector (see section 3.2)
• Default = 000000
• 6-digit entry is required; for 5-digit serial numbers, enter [0], then the number
(See section 3.1 “A Note About Electronic Serial Numbers”.) l_____l_____l_____l_____l_____l_____l
Zone l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l
Serial Number l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l
Serial Number l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l_____l_____l_____l
Zone l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l
17
Troubleshooting
S E C T I O N 7
S
Getting Started
E C T I O N 2
1. When I enter [0013] PC4164-433 options, the keypad gives me a long beep.
You cannot enter ESNs unless the PC4164-433 wireless receiver is enrolled. See section
2 for instructions on enrolling the PC4164-433 module.
2. I have entered the ESN for the device but when I violate the device, the zone does not show open on the keypad.
Check the following:
• Check that you are looking at a keypad on the same partition as the device you are testing
• Check that the ESN has been entered correctly
• Check that the zone is assigned to one or more partitions
This section describes how to set up and enroll the PC4164-433 module.
2.1 Unpack the PC4164-433 Receiver
Check that the following parts are in your PC4164-433 package:
• PC4164-433 PCB
• PC4164-433 plastic cabinet
• 2 antennas
2.2 Install the Antennas
Attach both antennas to the terminals marked ANT1 and ANT2, (not GND1 and GND2).
Install the antennas ONLY as shown in the following diagrams:
3. When I try a module placement test I get no result or “Bad” results.
Check the following (see sections 4.1 and 4.2 for more information on testing devices):
• Verify that you are testing the correct zone
• Verify that the correct ESN was entered when the device was enrolled
• Verify that the device is in range of the PC4164-433 receiver. Try testing the device in the same room as the receiver
• Confirm that the PC4164-433 receiver is properly connected to the Combus (see section 2 for PC4164-433 receiver setup and wiring instructions)
• Check that you are testing the zone correctly (see sections 4.1 and 4.2 for testing instructions)
• Check that the batteries are working and installed correctly
• Look for large metal objects that may be preventing the signal from reaching the
PC4164-433 receiver
The device must be located where consistent “Good”or “Fair” results are obtained. If several devices show “Bad” results, or if panic pendants and wireless keys operate inconsistently, move the receiver. See section 2.3 for tips on choosing a mounting location for the PC4164-433 receiver.
4. The LED on the motion detector does not turn on when I walk in front of the unit.
The LED is for walk test purposes only. See your WLS904(P)(L)-433 Instruction Sheet for walk test instructions.
DO NOT install the antennas this way:
2.3 Find a Mounting Location for the PC4164-433
NOTE: Do not permanently mount the PC4164-433 now. Mount the PC4164-433 receiver after you have done placement tests with all the wireless devices (see sections 4.1 and 4.2).
Find a place that is:
• Dry
• Central to the proposed placement of all wireless devices
• As high as possible
• Far from sources of interference, including: electrical noise such as computers, televisions and electric motors in appliances and heating and air conditioning units; large metal objects like heating ducts and plumbing which may shield the antenna.
Make sure that electrical wires will not run over the antenna(s) of the module when it is mounted.
When mounting the PC4164-433 in a basement, place the module as high and as close to the underside of the first floor as possible. The range of the module will be reduced if the unit is mounted below ground level.
2.4 Connecting the PC4164-433
The PC4164-433 is connected to the control panel via the Combus.
CAUTION: Remove all power from the panel while connecting modules to the Combus.
Diagram 1
Wire the PC4164-433 to the Combus of the PC4010/
PC4020/P-16128 according to diagram 1: https://www.e-camere.ro/alarma-antiefractie/module/DSC/PC-4164/
PC4010/PC4020/P-16128
Main Control Panel
16 5
G E T T I N G S T A R T E D A D D I T I O N A L P R O G R A M M I N G N O T E S
2.5 Enroll the PC4164-433
You must enroll one PC4164-433 module with the PC4010/PC4020/P-16128 panel before you can install and program the WLS9XX devices.
The following trouble conditions apply to the PC4164-433 receiver. For a description of all troubles, please see Section 16 “Diagnostics and Troubleshooting ” in the PC4010/PC4020/
P-16128 Installation Manual.
• PC4164-433 Tamper • Smoke Low Sense
If you are installing a PC4020/P-16128 v3.2 or higher, you can enroll up to eight PC4164-
433 wireless receivers. This will give you a greater range in which to install wireless devices. It will also allow you to install backup wireless receivers with overlapping ranges, to provide increased security for the wireless zones on the system. If you are installing a PC4010/PC4020/P-16128 v3.1 or v3.0, you can only enroll one PC4164-433 receiver.
NOTE: The maximum number of wireless zones you can enroll on the a PC4010 is 56, and on a PC4020/P-16128 is 64, even if you install more than one PC4164-433 wireless receiver.
• RF Jam Detected (see below)
• Device Fault (see section 6.1)
• Device Low Batt
Wireless Device Low Battery Trouble Transmission Delay
When a device reports a low battery trouble, the keypad will indicate the trouble immediately, but the panel will delay transmission of the trouble to the monitoring station. You can program the length of the delay (in days) in Installer’s Programming. If the user does not correct the low battery condition before the delay expires, the low battery trouble will be transmitted.
NOTE: You cannot have more than 64 zones on the PC4010 and 128 zones on the PC4020/P-
16128. If the total number of zones theoretically available on the zone expanders exceeds the maximum for the panel, you will not be able to use the extra zones.
The low battery alarm and restoral codes will only be reported once per armed period.
The low battery restore transmission is not delayed. The default transmission delay is 7 days.
A description of how to enroll keypads and modules is in your PC4010/PC4020/P-
16128 Installation Manual.
Follow these steps to enroll your PC4164-433 module.
1.
At a PC4010/PC4020/P-16128 system LCD keypad, enter [
✱
][8][Installer’s Code] to go to the Installer’s Programming section.
To change the transmission delay:
1.
At an LCD keypad, enter [ ✱ ][8][Installer’s code].
2.
Enter Ref #[00040211] to go to the 4164 Low Bat Dly
3.
Enter the new transmission delay (from 000 to 255 days).
2.
Enter Ref #[0200], to go to the Enroll Module
3 Scroll to PC41xx Zn. Ex.,
✱
]. The LCD keypad will display Cr eate T amper on
4.
To exit, press [#].
Replacing Batteries in Wireless Devices
4.
Tamper the PC4164-433:
1.
Remove the cover of the device from its backplate. This creates a tamper condition on the zone.
i) make sure the connection between the T1 and T2 tamper terminals is closed
(tamper zone secured) (see Diagram 1).
2.
Refer to the battery installation instructions on the installation sheet of each component. Ensure the proper orientation of the batteries as you install them.
ii) open the normally closed contact, if present, or remove the wiring from one of the tamper terminals (tamper zone violated). The change from secure to violated will enroll the module.
3.
When the fresh batteries are in place, re-attach the cover to the backplate. The tamper is restored and the zone sends a battery trouble restoral signal to the PC4164-433 receiver. The battery trouble is now clear.
5.
The LCD keypad will display PC4164-433 Zn. Ex. Mod XX Enr olled.
module number of the PC4164-433 receiver in the Programming Worksheets .
NOTE: When batteries in one device need to be replaced, the batteries in all devices should be replaced at the same time.
6.
When the module is enrolled, re-secure the connection between the T1 and T2 terminals.
7.
To enroll another PC4164-433 module, repeat steps 2 to 6. To exit module enrollment, press [#].
Enable RF Jam Detect Trouble
The RF Jam Detect trouble condition will be generated and logged when the PC4164-433 module detects an attempt to block RF signals. This tells the user that the PC4164-433 module is not receiving wireless device transmissions. The panel will transmit the General
System Trouble reporting code.
The PC4164-433 module is now installed and enrolled on the PC4010/PC4020/P-16128 system. You can now enroll and program the wireless devices (see Section 3).
T o enable warning of this tr ouble condition
1.
At an LCD keypad, enter [ ✱ ][8][Installer’s Code].
2.
Enter Ref #[000200] to go to the System T oggles
3.
Scroll to RF Jam Detect
4.
Press [ ✱ ] to toggle the option ON or OFF.
5.
To exit System Toggles, press [#}.
https://www.e-camere.ro/alarma-antiefractie/module/DSC/PC-4164/
NOTE: This option must be turned on for UL/ULC/CE installations.
6 15
Additional Programming Notes
S E C T I O N 6
Enroll & Program Wireless Devices
S E C T I O N 3
6.1 Device Fail Time
When supervision of a wireless detector is turned ON, the panel will show a trouble if a wireless zone stops working or is removed from the system. When supervision is turned
OFF, the panel will not show a trouble.
NOTE: Wireless keys are NOT supervised.
A zone supervisory is a test transmission that each wireless zone sends to the PC4164-433 receiver. When the PC4164-433 module receives the supervisory transmission from the zone, the PC4164-433 module will transmit this information to the control panel.
If the control panel does not get a supervisory transmission from a zone within the
Device Fail time, the zone will be considered “missing”, causing a Device Fault.
The next supervisory transmission that the PC4164-433 receives from the “missing” zone will restore communication with that zone and restore the Zone Supervisory Fault.
The Device Fail timer will also be reset.
Change the Supervision Option
1.
At an LCD keypad, enter [ ✱ ][8][Installer’s Code].
2.
Enter Ref #[001306] to go to the Supv W indow
3.
Devices are listed by zone number in the order in which they were enrolled. Scroll to each device. Press [ ✱ ] to turn the supervision option ON or OFF for that device.
4.
To exit, press [#].
Change the Device Fail Time
The default amount of time is 3 hours.
NOTE: This must be changed to 24 hours fo r systems using North American devices.
1.
At an LCD keypad, enter [ ✱ ][8][Installer’s Code].
2.
Enter Ref #[001307] to go to the Device Fail T ime
3.
Enter the time as [HHMM] (valid entries 01:00 - 23:59).
4.
To exit, press [#].
6.2 Trouble Conditions
The PC4010/PC4020/P-16128 always watches for possible trouble conditions. If a trouble condition occurs, the LCD keypad “Trouble” light will turn on and the keypad will beep. Press [ ✱ ][2] to display the trouble conditions.
This section describes how to enroll and program the following wireless devices:
• wireless detectors ((P)WLS904/(P)WLS904P(L)-433, WLS906-433, (P)WLS907(T)-433,
WLS912L-433, (P)WLS914-433 (North America only), (P)WLS925L-433 and
WLS935L-433)
• wireless keys (WLS909-433/WLS919-433)
For more information on these devices, read the instruction sheet included with each device.
3.1 A Note about Electronic Serial Numbers (ESN)
In order to reduce the occurrence of wireless devices with the same serial number, 6digit serial numbers are now printed on the back of each wireless device. The 6-digit serial numbers include hexadecimal digits. For instructions on programming hexadecimal numbers, see your PC4010/PC4020/P-16128 Installation manual, section 3:
How to Program .
Older wireless devices will only have 5-digit serial numbers. To enroll these devices, enter [0], then the 5-digit serial number.
3.2 Enrolling Wireless Detectors
NOTE: Before you permanently mount wireless devices, test each one in its intended mounting location to make sure that it can communicate properly with the PC4164-433. Test the device at least 3 times. See Section 4.1 for more information.
1.
At a system LCD keypad, enter [ ✱ ][8][Installer’s Code].
2.
Enter Ref #[001300] to go to the Enr oll Device
This section will only be available if you have already enrolled the PC4164-433 module with the panel (see Section 2.5
).
3.
Look at the back of the first wireless device you want to enroll. If the device has a 6-digit serial number, enter it now. If the device only has a 5-digit number, enter a [0] and then the 5-digit number.
4.
PC4020/P-16128 v3.2 and higher panels: The LCD keypad prompts Enr oll Device Zone
PC4010/PC4020/P-16128 v3.1 and v3.0 panels: The system automatically assigns the next available zone number to the device, and displays the zone number on the keypad.
NOTE: If the zone selected is a hardwired zone, the wireless zone will replace it. However, you cannot replace an AML or PC4820 zone with a wireless zone. If you select an AML or
PC4820 zone, the keypad will sound an error tone.
5.
The LCD keypad will display Enroll Device Serial # [ ]
4 until all devices have been enrolled.
6.
To exit device enrollment, press [#].
Program Partitions and Zones
Now that you have enrolled and mounted the wireless devices, you should program your PC4010/PC4020/P-16128 partitions and zones. See your PC4010/PC4020/P-16128 https://www.e-camere.ro/alarma-antiefractie/module/DSC/PC-4164/
14 7
I N S T A L L I N G W I R E L E S S D E V I C E S
3.3 Enrolling and Programming Wireless Keys
For wireless keys to work on the system, you need to enroll them and then program the function buttons. You can enroll up to 16 wireless keys on the PC4164-433 receiver.
Step 1: Enrolling Wireless keys
1.
At a PC4010/PC4020/P-16128 system LCD keypad, enter [ ✱ ][8][Installer’s Code] to go to the Installer’s Programming section.
2.
Enter Ref #[001300], to go to the Enr oll Device will only be available if you have already enrolled the PC4164-433 module with the panel (see Section 2.6
). The LCD keypad will display
3.
Look at the back of the wireless key. If it has a 6-digit serial number, enter it now. If it only has a 5-digit number, enter a [0] and then the 5-digit number.
4.
The display will show Enr oll Device WKEY #XX which the WLS909-433/WLS919-433 is assigned (01 to 16).
5.
Record the serial number and assigned slot number in the programming worksheets in the back of this manual.
6.
Continue with steps 3 to 5 until all wireless keys have been enrolled.
Wireless Key Reporting
When you enroll a wireless key, the panel will assign a user number (0101 to 0116) to the key. The wireless key enrolled in slot 01 will be given user number 0101, slot 02 will have user number 0102, and so on. This allows the panel to transmit and log the arm/ disarm events performed by each wireless key.
You can still program access codes for user numbers 0101 to 0116.
For example:
User 0101 arms or disarms using an access code - the panel transmits and logs Closing/
Opening User 0101 .
A user arms or disarms using wireless key 01 - the panel transmits Closing/Opening User
0101 and logs Closing/Opening User 0101 AND Closing/Opening WKey #01 .
Step 2: Program the Wireless Key Function Buttons
All wireless keys have four programmable function buttons. When you press and hold a button for two seconds, the programmed function will be executed. Each function button can be assigned to one partition.
NOTE: Wireless key function buttons will not work when the partition(s) to which they are assigned are being accessed for zone bypassing or programming.
1.
From Installer’s Programming, enter Ref #[001304], to go to WLSKey Functions
2.
Scroll to the slot number of the key you want to program (01-16). Press [ ✱ ].
3.
Scroll to the number of the button you want to program (1-4). Press [ ✱ ].
D E L E T I N G & R E P L A C I N G D E V I C E S
5.3 Deleting Device Serial Numbers
Entering this programming section will erase the serial numbers of all the wireless devices.
Zone and partition programming will not be affected. When you re-enroll the wireless devices, remember to change the zone and partition programming, if necessary.
1.
At an LCD keypad, enter [ ✱ ][8][Installer’s Code].
2.
Enter Ref #[001308], to go to Default W ir eless ✱ ].
3.
The LCD will display Confirm Default Pr ess ‘ ✱ ’. To confirm the default procedure, press [ ✱ ]. To cancel the default procedure, press any other key.
5.4 Deleting a PC4164-433 Module
To delete a PC4164-433 module, enter the following at any enrolled keypad:
1.
Enter Installer’s Programming by pressing [ ✱ ][8][Installer’s Code].
2.
Enter reference number [0201] to go to Delete Device ✱ ].
3.
Scroll through the different modules, type and select PC41XX. Press [ ✱ ] to select.
4.
Scroll to the correct module type, then to the correct module number. For example, to delete PC4164-433 module 04, scroll to “PC41XX (04).” Press the [ ✱ ] key to delete the module.
NOTE: If you are removing all PC4164-433 modules from the system, you will need to perform a wireless default BEFORE you delete the last module. If you do not, the hardwired zones may not work correctly. (See section 5.3 ‘Erasing Device Serial Numbers’ above.) https://www.e-camere.ro/alarma-antiefractie/module/DSC/PC-4164/
8 13
Deleting & Replacing Devices
S E C T I O N 5
If a device is not working, or you need to change the setup of the system, you may need to replace or delete wireless devices. Follow the appropriate procedure in this section.
5.1 Replacing Devices
Wireless devices are divided into the following classes:
2
3
4
6 & 9
(P)WLS907(T)-433/(P)WLS925L-433/WLS935L-433
(P)WLS904-433/(P)WLS904P-433/(P)WLS914-433 (N.A. only)
WLS906-433-433
WLS909-433/WLS919-433
This section describes how to replace one device with another device of the same class.
All programming that was used with the old device will be used with the new device.
For example, a (P)WLS907(T)-433 can be replaced with another (P)WLS907(T)-433.
1.
At a system LCD keypad, enter [ ✱ ][8][Installer’s code].
2.
Enter Ref #[001302] to go to the Replace Device
I N S T A L L I N G W I R E L E S S D E V I C E S
4.
Enter the 2-digit number of the function you want to select, or scroll to the function you want to assign to that button and press [ ✱ ]. The following functions may be programmed:
00 Null Key
01 Stay Arm
02 Away Arm
03 No-Entry Arm
04 Chime On/Off
05 System Test
06 Quick Exit
07 Arm Interior
08-15 [ ✱ ][7] Command Outputs 1-8
16 Fire Alarm
17 Auxiliary Alarm
18 Panic Alarm
19 Disarm (Off)
NOTE: If programmed, these options do not require access code entry regardless of other system options. The programmed function will be executed immediately.
5.
The LCD keypad will show Select (01) Partition 1 the button to work in, and press [ ✱ ] to select.
6.
Repeat steps 3 to 5 until all the buttons are programmed.
7.
Repeat steps 4 to 6 until all the wireless keys are programmed.
8.
To exit, press [#].
NOTE: When a wireless key is used to disarm a partition, all courtesy pulse outputs enabled for that partition will activate for two minutes.
Now that you have enrolled and programmed all the wireless devices, you will need to test the devices and mount wireless devices using zones. See section 4 for more information.
3.
Use the [<][>] keys to scroll to the device to be deleted, then press [ ✱ ]. The LCD keypad will display
W ith Device
4.
Enter the serial number of the new device. The LCD keypad will display Device
NOTE: You cannot replace devices of different classes. (For example, a motion detector cannot be replaced by a universal transmitter.) If you need to do this, you must delete the first device
(see ‘Deleting Devices’ below) and enroll the second. You will also need to change the programming for the new device. See Section 3: ‘Enrolling and Programming WLS9XX
Wireless Devices’.
5.
To exit, press [#].
5.2 Deleting Devices
This section describes how to delete any of the enrolled wireless devices from the
PC4164 433 receiver, and from the system.
1.
At a system LCD keypad, enter [ ✱ ][8][Installer’s Code].
2.
Enter Ref #[001301] to go to the Delete Device
3.
Use the [<][>] keys to scroll to the device you want to delete; then press [ ✱ ]. The
4.
To exit, press [#].
If you enroll a device of the same class as the one deleted (See ‘Replacing Devices’, https://www.e-camere.ro/alarma-antiefractie/module/DSC/PC-4164/
Make sure you update the programming for each device you enroll.
12 9
Testing & Mounting Devices
S E C T I O N 4
T E S T I N G & M O U N T I N G D E V I C E S
You should test each device you have enrolled to ensure good signal strength between the devices and the PC4164-433 receiver. Follow the instructions in this section to test wireless devices which use zones, wireless keys and handheld keypads.
If several wireless devices produce BAD test results, you may need to move the PC4164-433 to a better location (see section 2.3 for tips on finding a location for the PC4164-433 module).
4.1 Test the Placement of the Wireless Detectors
It is very important to test each wireless device before it is mounted. Following these steps will test the placement of (P)WLS904/(P)WLS904P(L)-433, WLS906-433,
(P)WLS907(T)-433, WLS912L-433, (P)WLS914-433 (North America only), (P)WLS925L-
433 & WLS935L-433 wireless devices, based on the signal strength between the PC4164-
433 module and the device:
NOTE: You cannot test the wireless key (WLS9X9-433) in this mode . See section 4.2 for instructions on testing wireless keys.
1.
Temporarily place the device in its intended mounting location.
2.
At a system LCD keypad, enter [ ✱ ][8][Installer’s Code].
3.
Device T est section.
4.
Enter [00] to have test results sounded on the keypad buzzers only. Enter [01] to have test results sounded by the system bells, as well as the keypad buzzers.
5.
Use the [<][>] keys to scroll to the device number and press [ ✱ ] to select it. The
For PC4020/P-16128 v3.2 system, the system keypad will also display the number of PC4164-433 receivers that reported the highest level result (e.g., “Placement Good by 2 Receivers”).
Devices indicating a bad result must be moved to another location. You may only have to move the device a few inches to correct a bad result.
NOTE: Do not mount any device where a “bad” test result was indicated.
If several wireless devices produce BAD test results, you may need to move the
PC4164-433 receiver to a better location (see section 2.3 for tips on finding a location for the PC4164-433).
8.
To test another device, press [#] once, then repeat steps 4 to 7. Continue to test the devices until both the PC4164-433 receiver and the devices are in good or fair locations.
9.
To exit Installer Programming, press [#].
4.2 Test Wireless Key Reception
The wireless key (WLS909-433/WLS919-433) cannot be tested using the module placement test described above. To ensure that the PC4164-433 is receiving transmissions from these devices, conduct the following tests:
Use the function keys to arm and disarm the system at several different points in the installation.
NOTE: Do not use a Fire, Auxiliary or Panic key to test your WLS9X9-433, as pressing these buttons will always notify your central station of a non-medical emergency.
6.
Activate the device being tested. A result will be displayed on the keypad or sounded by the keypad or bell.
(P)WLS904-433/(P)WLS904P(L)-433/(P)WLS914-433 (N. A. only) : Remove the detector from the backplate, wait for the result to be presented, then re-attach the detector to its backplate.
If these devices do not operate from all points in the installation, you will need to move the
PC4164-433 receiver. Moving the PC4164-433 higher will usually improve the reception.
If you move the PC4164-433 receiver, repeat the tests described in sections 4.1 and 4.2 on all the wireless devices. Continue to test the devices until you have found locations with good or fair placement results for all wireless detectors, and there is acceptable range between the PC4164-433 and the WLS9X9 devices.
WLS906-433: Hold the supplied magnet near the raised line on the outer rim of the bracket. Wait for the result to be presented. The magnet can now be removed and the next result must be waited for.
(P)WLS907(T)-433/(P)WLS925L-433/WLS935L-433: Open the contact by moving the magnet away from the unit. If the unit is attached to a door or a window, open the door or window to activate the device. Wait for the result to be presented. Close the contact by moving the magnet near the unit. If the unit is attached to a door or a window, close the door or window to restore the device. Wait for the result to be presented.
4.3 Mount the PC4164-433 Receiver and Wireless Devices
Do not permanently mount the PC4164-433 until you have tested reception with all the wireless devices (see sections 4.1 and 4.2). Once you have done this and have a good location, mount the PC4164-433:
1. Remove the four screws that attach the PC4164-433 module to the plastic cabinet.
2. Pull the Combus wires through the hole at the back of the cabinet.
3. Mount the cabinet securely to the wall.
WLS912L-433: Press and hold the test mode tab. Wait for the result to be presented.
Release the test mode tab. Wait for the result to be presented.
4. Reattach the PC4164-433 module to the mounted cabinet using the 4 mounting screws.
Mount the Wireless Detectors
7.
Read the placement test results:
If you have conducted the placement test described in section 4.1 and got 3 “Good” or
“Fair” results in a row for each device, you can mount the wireless devices. See the installation sheet for each device for mounting instructions.
Good
Fair
Good
Fair
1 Beep/squawk
2 Beeps/squawks
Bad Bad 3 Beeps/squawks https://www.e-camere.ro/alarma-antiefractie/module/DSC/PC-4164/ presented between each test on the same device. You may mount your device where results were good or fair.
10 11

Download
Advertisement