INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
INSTALLATION AND
OPERATING INSTRUCTIONS
$10.00
CERTIFIED UNDER CANADIAN AND UNITED STATES STANDARD: CSA 2.22, ANSI Z21.50 VENTED GAS FIREPLACES
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
WHD48N
SAFETY INFORMATION
NATURAL GAS
!
WARNING
If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fi re department.
- Installation and service must be performed by a qualifi ed installer, service agency or the supplier.
!
WHD48P
PROPANE
SAFETY BARRIER
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
HOT GLASS WILL CAUSE
BURNS .
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
Decorative Product: Not for use as a heating appliance.
DANGER
DO NOT TOUCH GLASS UNTIL
COOLED .
NEVER ALLOW CHILDREN TO
TOUCH GLASS .
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
!
AVERTISSEMENT
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
LA VITRE CHAUDE CAUSERA
DES BRÛLURES.
NE PAS TOUCHER LA VITRE
AVANT QU’ELLE AIT REFROIDI.
NE JAMAIS LAISSER LES
ENFANTS TOUCHER LA VITRE.
Une barriére conçu à réduire le risque de brûlures causées par le verre chaud est fourni avec l’appareil et sera installé pour la protection des enfants et d’autres personnes à risque.
FR
PG
53
EN
EN
2
TABLE OF CONTENTS
1.0 INSTALLATION OVERVIEW
2.0 INTRODUCTION
2.1 DIMENSIONS
2.2
2.3
2.4
GENERAL INSTRUCTIONS
GENERAL INFORMATION
RATING PLATE INFORMATION
3.0 VENTING
3.1
3.2
3.3
3.3.1
3.4
3.5
3.6 DEFINITIONS
3.7
3.8
3.9
VENTING LENGTHS AND COMPONENTS
TYPICAL VENT INSTALLATION
SPECIAL VENT INSTALLATIONS
PERISCOPE TERMINATION
VENT TERMINAL CLEARANCES
VENTING APPLICATION FLOW CHART
ELBOW VENT LENGTH VALUES
HORIZONTAL TERMINATION
VERTICAL TERMINATION
4.0 INSTALLATION
4.1
4.2
4.3
4.3.1
4.3.2
4.3.3
4.3.4
4.3.5
4.3.6
4.4
4.5
4.6
4.7
WALL AND CEILING PROTECTION
MOUNTING PLATE INSTALLATION
USING FLEXIBLE VENT COMPONENTS
APPLIANCE VENT CONNECTION
VERTICAL INSTALLATION
HORIZONTAL AIR TERMINAL INSTALLATION
VERTICAL AIR TERMINAL INSTALLATION (FLEXIBLE)
HORIZONTAL AIR TERMINAL INSTALLATION
EXTENDED HORIZONTAL AND CORNER TERMINAL INSTALLATION
MOUNTING THE WHD48
GAS INSTALLATION
MOBILE HOME
MINIMUM CLEARANCE TO COMBUSTIBLES AND NON-COMBUSTIBLES
5.0 FINISHING
5.1
5.2
5.3
5.4
5.5
6.0
6.1
HOUSING PANEL INSTALLATION
DOOR REMOVAL / INSTALLATION
GLASS MEDIA
SURROUND INSTALLATION / REMOVAL
LOGO PLACEMENT
OPTIONAL INSTALLATION
RECEIVER LOCATION/WIRING
ELECTRICAL INFORMATION
HARD WIRING CONNECTION
WIRING DIAGRAM
7.0
7.1
7.2
8.0 OPERATION
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
8.10
8.11
8.12
8.13
OPERATING INSTRUCTIONS
LIGHTING INSTRUCTIONS
GENERAL TRANSMITTER LAYOUT
INITIALIZING THE TRANSMITTER/BATTERY HOLDER FOR THE FIRST TIME
TEMPERATURE DISPLAY
FLAME HEIGHT TIME
LED ON/OFF LIGHT CONTROL
CONTINUOUS PILOT / INTERMITTENT PILOT (CPI / IPI) SELECTION
CHILD PROOF FUNCTION
LOW BATTERY / MANUAL BYPASS
IN THE EVENT OF A POWER FAILURE
TIMED BLOWER
MANUAL OPERATION
9.0 ADJUSTMENTS
9.1
9.2
9.3
PILOT BURNER ADJUSTMENT
VENTURI ADJUSTMENT
FLAME CHARACTERISTICS
10.0 MAINTENANCE
10.1
10.2
10.3
10.4
ANNUAL MAINTENANCE
CARE OF GLASS
CARE OF PLATED PARTS
DOOR GLASS REPLACEMENT
11.0 REPLACEMENTS
11.1 OVERVIEW
11.2 VALVE TRAIN ASSEMBLY
12.0 ACCESSORIES
13.0 TROUBLESHOOTING
14.0 WARRANTY
15.0 SERVICE HISTORY
16.0 NOTES
NOTE: Changes, other than editorial, are denoted by a line in the margin.
W415-1606 / 09.09.16
29
29
30
30
30
31
33
33
34
35
31
31
32
33
35
35
35
36
36
37
37
37
38
39
26
26
27
27
28
28
20
20
21
22
17
18
19
19
22
23
24
24
25
42
43
44
40
40
40
41
45
46
48
49
50
7
7
5
6
8
3
4
11
12
12
12
9
10
10
10
13
15
17
C
B
A
D
1
1
2 3
1.0 INSTALLATION OVERVIEW
4
Venting, see
“VENTING” section.
5
3
EN
Mantel, see
“MINIMUM
MANTEL
CLEARANCES” section.
7
2
Side Wall, see
“MINIMUM
CLEARANCES TO
COMBUSTIBLES” section.
3
8
D
C
4
Rating plate, see “RATING
PLATE INFORMATION” section.
5
W415-1606 / 09.09.16
7
This drawing is the property of Wolf Steel LTD. or NAC. It is not to be reproduced nor used in any manner without our consent. All rights are reserved.
UNLESS OTHERWISE NOTED OR DEPICTED ALL DIMENSIONS ARE OUTSIDE IN INCHES ALL SURFACES ARE CONSIDERED CLASS "D"
REFER TO ENG-009 AND ENG-010 FOR SURFACE FINISH CRITERIA
8
A
B
EN
4
2.0 INTRODUCTION
!
WARNING
• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
• ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS
PROHIBITED.
• Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi re or injury.
• Risk of fi re or asphyxiation do not operate appliance with fi xed glass removed.
• Do not connect 110 volts to the control valve.
• Risk of burns. The appliance should be turned off and cooled before servicing.
• Do not install damaged, incomplete or substitute components.
• Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges may be sharp.
• Do not burn wood or other materials in this appliance.
• Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
• Young children should be carefully supervised when they are in the same room as the appliance.
Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to an appliance, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
• Clothing or other fl ammable material should not be placed on or near the appliance.
• Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies.
• Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.
• Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
• Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the fl oor.
• Any safety screen, guard or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
• The appliance is a vented gas-fi red appliance. Do not burn wood or other materials in the appliance
• It is imperative that the control compartments, burners and circulating blower and its passageway in the appliance and venting system are kept clean. The appliance and its venting system should be inspected before use and at least annually by a qualifi ed service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The appliance area must be kept clear and free from combustible materials, gasoline and other fl ammable vapors and liquids.
• Under no circumstances should this appliance be modifi ed.
• This appliance must not be connected to a chimney fl ue pipe serving a separate solid fuel burning appliance.
• Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
• Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualifi ed service person.
• Do not strike or slam shut the appliance glass door.
• When equipped with pressure relief doors, they must be kept closed while the appliance is operating to prevent exhaust fumes containing carbon monoxide, from entering into the home. Temperatures of the exhaust escaping through these openings can also cause the surrounding combustible materials to overheat and catch fi re.
• Only doors / optional fronts certifi ed with the appliance are to be installed on the appliance.
• Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all plastic bags, these are not toys and should be kept away from children and infants.
• As with any combustion appliance, we recommend having your appliance regularly inspected and serviced as well as having a Carbon Monoxide Detector installed in the same area to defend you and your family against Carbon
Monoxide.
• Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance.
Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or damage of decorations, a T.V. or other electronic components.
• A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed.
• If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
• Installation and repair should be done by a qualifi ed service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
3.2C
W415-1606 / 09.09.16
2.1 DIMENSIONS
5
EN
W415-1606 / 09.09.16
EN
6
2.2 GENERAL INSTRUCTIONS
!
WARNING
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
FIRE RISK. EXPLOSION HAZARD.
THE APPLIANCE MUST NOT BE OPERATED AT TEMPERATURES BELOW FREEZING (32°F / 0°C).
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example in Massachusetts State:
• This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth of Massachusetts.
• The appliance damper must be removed or welded in the open position prior to installation of an appliance insert or gas log.
• The appliance off valve must be a “T” handle gas cock.
• The fl exible connector must not be longer than 36 inches (914mm).
• A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.
The installation must conform with local codes or, in absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in accordance with the current standard CAN/CSA
Z240MH Series, for gas equipped mobile homes, in
Canada or ANSI Z223.1 and NFPA 54 in the United
States.
We suggest that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
www.nficertified.org
As long as the required clearance to combustibles is maintained, the most desirable and benefi cial location for an appliance is in the center of a building, thereby allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the room where the appliance is to be located should be considered. If possible, you should choose a location where the vent will pass through the house without cutting a fl oor or roof joist.
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
4.1C
W415-1606 / 09.09.16
2.3 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
RATES AND EFFICIENCIES
Altitude (FT)
Max. Input (BTU/hr)
Min. Inlet Gas Supply
Pressure
Max. Inlet Gas Supply
Pressure
Manifold Pressure (Under
Flow Conditions)
NG
0-4,500*
28,000
4.5" (11mb) w.c.
13" (32mb) w.c.
3.5" (9mb) w.c.
P
0-4,500*
28,000
11" (27mb) w.c.
10" (25mb) w.c.
* When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m).
70.78%
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile home installation. The natural gas model can only be installed
CWHD48 in a mobile home that is permanently positioned on its site and fueled with natural gas. This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
70.78%
WHD48
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and must be installed.
FRENCH:
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
7
2.4 RATING PLATE INFORMATION
For rating plate location, see “INSTALLATION OVERVIEW” section.
Cote énergétique des foyers à gaz 70.78%
Basée sur la norme CSA P.4.1-02
Modèle No.
EN
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIÉ CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
DIRECT VENT, VENTED GAS FIREPLACES. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. THIS APPLIANCE MUST BE
INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT
ANSI Z223.1, OR CSA B149, INSTALLATION CODES. FOR USE WITH BARRIER W565-0227.
FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
0-4500FT (0-1370m)
PRESSION D'ALIMENTATION MIN:
COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX:
WHD48N
7" D'UNE
COLONNE D'EAU (GN)
9700539 (WSL)
CWHD48N
28,000 BTU/h
19,000 BTU/h
70.8%
FOYER À GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE
SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI
MODEL
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE
MAISONS MOBILES ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LA
Cote énergétique des foyers à gaz
CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES
SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. CODES. INSTALLER L’APPAREIL SELON LES
CODES OU RÈGLEMENTS LOCAUX, OU EN L’ABSENCE DE TELS RÈGLEMENTS, SELON LES
CODES D’INSTALLATION ANSI Z223.1 OU CSA-B149 EN VIGUER.
POUR UNE UTILISER AVEC
ALTITUDE / ÉLÉVATION
INPUT / ALIMENTATION
BARRIÈRE W565-0227
4001657 (NGZ)
REDUCED INPUT / ALIMENTATION RÉDUITE
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING :
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS / DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES *:
P4
NORME DE SÉCURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24
CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE
(WUSA)
. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE TROUVENT DANS LE
0-4500FT (0-1370m)
28,000 BTU/h
23,000 BTU/h
70.8%
70.78%
Basée sur la norme CSA P.4.1-02
Modèle No.
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
CWHD48
MIN SUPPLY PRESSURE: 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN:
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE:
11" D'UNE
PRESSION D'ALIMENTATION MAX:
COLONNE D'EAU (P)
10" D'UNE
13" W.C. (LP)
13" D'UNE
UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ
AVEC CET APPAREIL. UTILISER AVEC LES PORTES
VITRÉES HOMOLOGUÉES SEULEMENT AVEC CETTE UNITÉ.
AVERTISSEMENT:
N’AJOUTEZ PAS À CET APPAREIL AUCUN MATÉRIAU DEVANT ENTRER EN CONTACT
AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
MANTEL / CEILING 15"
SIDES 7"
MANTEAU / PLAFOND
CÔTÉS
VENT SIDES / BOTTOM 1" CÔTÉS DE L'ÉVENT / ÉVENT INFÉRIEUR
FLOOR 6" PLANCHER
VENT TOP 3" ÉVENT SUPÉRIEUR
* SEE INSTALLATION MANUAL FOR FURTHER INFORMATION / VOIR MANUEL D'INSTALLATION POUR PLUS
D'INFORMATION.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
15"
7"
1"
6"
3"
RÉFÉRER AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR LES LONGUEURS D'ÉVACUATION MINIMALE
ET MAXIMALE.
WOLF STEEL LTD.
MAX SIZE: 8.5" X 4.75"
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION
MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
VENT-AIR INTAKE SYSTEM. /
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'ÉVACUATION PROPRE À NAPOLEON. RÉFÉRER AU
MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATION PRÉCISE. IL EST IMPORTANT DE BIEN RÉINSTALLER
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE
SERIAL NUMBER/NO. DE SÉRIE: WHD48
W385-2131
W415-1606 / 09.09.16
HOLE TO BE 0.250"Ø
MATERIAL: CLASS III A-2, PERMANENT LABEL, WATERPROOF, .010MIL VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER.
MIN. LETTERING FOR " NOT FOR USE WITH SOLID FUEL.
", " UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI. " TO BE 10 POINT ARIAL, BOLD FACE,
UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT.
BLACK LETTERING ON WHITE BACKGROUND.
SERIAL NUMBERS TO BE ASCENDING FROM WHD48 015416
WOLF STEEL LTD.
TITLE: RATING PLATE
REVISION:
WHD48 DWG#: W385-2131
DATE: 06.22.16_
R.T.
EN
8
3.0 VENTING
!
WARNING
RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.
IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT
(0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM
COMBUSTIBLES. USE WOLF STEEL LTD. SUPPORT RING ASSEMBLY W010-0067 OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES
FOR BOTH VERTICAL AND HORIZONTAL RUNS. SPACERS ARE ATTACHED TO THE INNER PIPE AT
PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER PIPE. THIS GAP IS
REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF
EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED.
THIS APPLIANCE USES A 5” (127mm) EXHAUST / 8” (203.2mm) AIR INTAKE VENT PIPE SYSTEM.
Refer to the section applicable to your installation.
For safe and proper operation of the appliance follow the venting instruction exactly. Deviation from the minimum vertical vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Provide a means for visually checking the vent connection to the appliance after the appliance is installed. Use a fi restop, vent pipe shield or attic insulation shield when penetrating interior walls, fl oor or ceiling.
NOTE: If for any reason the vent air intake system is disassembled; reinstall per the instructions provided for the initial installation.
NOTE: This appliance must be installed with a continuous connection of exhaust and air intake vent pipes. Utilizing alternate constructions such as a chimney as part of the vent system is not permitted.
7.2C
W415-1606 / 09.09.16
9
3.1 VENTING LENGTHS AND COMPONENTS
Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, clearances from vent pipes to combustibles and air terminal locations as set out in this manual apply to all vent systems and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp, American Metal
Amerivent and Metal-Fab follow the installation procedure provided with the venting components.
A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier:
PART
Duravent
5”/8”
W175-0170
SUPPLIER
Wolf Steel
WEBSITE www.duravent.com
Amerivent
Direct Temp
SuperSeal
5DSC-N2
5DT-AA
5DDA
American Metal
Selkirk
Metal-Fab www.americanmetalproducts.com
www.selkirkcorp.com
www.mtlfab.com
For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure found on the website for your venting supplier.
EN
For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed using a red high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the appliance fl ue collar which must be sealed using the black high temperature sealant Mill Pac.
When using Wolf Steel venting components, use only approved Wolf Steel rigid / fl exible components with the following termination kits: wall terminal kit GD422-1 , GD422R-1 , or 1/12 to 7/12 pitch roof terminal kit GD410 , 8/12 to
12/12 roof terminal kit GD411 , fl at roof terminal kit GD412 or periscope kit GD401 (for wall penetration below grade).
With fl exible venting, in conjunction with the various terminations, use either the 5 foot (1.5m) vent kit GD420 or the 10 foot (3.1m) vent kit GD430 .
For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum.
The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged.
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not be combined.
These vent kits allow for either horizontal or vertical venting of the appliance. When terminating horizontally, the maximum allowable horizontal run is 20 feet (6.1m). When terminating vertically, the maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is two horizontally or three vertically (excluding the appliance and the air terminal connections) when using fl exible venting.
Horizontal runs may have a 0” (0mm) rise per foot/meter however for optimum performance it is recommended that all horizontal runs have a minimum 1/4” rise per foot or 21mm per meter using fl exible venting. For safe and proper operation of the appliance, follow the venting instructions exactly.
A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. Local codes or regulations may require different clearances.
Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1¼”
(31.8mm) air gap all around between the inner liner and outer liner is required for safe operation.
8.3C
W415-1606 / 09.09.16
EN
10
3.2 TYPICAL VENT INSTALLATION
16" (40.6CM)
MINIMUM
40 FT (12M)
MAXIMUM
3 FT (1M)
MINIMUM
14" (35.5CM) MAXIMUM
19 1/2"
(49.5CM)
19 1/2" (49.5CM)
MINIMUM PLUS
RISE*
A ppliance shown without surround.
* S ee "VENTING" section
3.3 SPECIAL VENT INSTALLATIONS
3.3.1 PERISCOPE TERMINATION
Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum
12” (304.8mm) above grade. The maximum allowable vent length is 10’ (3.1m) for a fi replace and 8’ (2.4m) for a stove.
12"
(30.5CM)
MINIMUM
TO GRADE
30" (76.2CM)
MINIMUM
19 1/2"
(49.5CM)
9.6B
W415-1606 / 09.09.16
3.4 VENT TERMINAL CLEARANCES
COVERED BALCONY APPLICATIONS ††*
11
EN
R
Q
S
G
P
A
B
C
Q
MIN
= 3 feet
(0.9m)
INSTALLATIONS
CANADA U.S.A.
12” (30.5cm)
12” (30.5cm) Δ
12” (30.5cm)
9” (22.9cm)
Clearance above grade, veranda porch, deck or balcony.
Clearance to windows or doors that open.
R
MAX
= 2 x Q
ACTUAL
12” (30.5cm)* 12” (30.5cm) * Clearance to permanently closed windows.
R
MAX
≤ 15 feet
(4.6m)
D
E
F
G
H
I
J
K
L
18”(45.7cm)** 18” (45.7cm)** Vertical clearance to ventilated soffits located above the terminal within a horizontal distance of 2’
18” (45.7cm)** 18” (45.7cm)** Clearance to unventilated soffit.
0” (0mm) 0” (0mm) Clearance to an outside corner wall.
12” (30.5cm)*** 12” (30.5cm)*** Clearance to an inside non -combustible corner wall or protruding non -combustible obstructions (chimney, etc.).
12” (30.5cm)*** 12” (30.5cm)*** Clearance to an inside combustible corner wall or protruding combustible obstructions (vent chase, etc.).
3’(0.9m)
3’ (0.9m)
3’(0.9m)****
3’ (0.9m)****
Clearance to each side of the center line extended above the meter / regulator assembly to a maximum vertical distance of 15’ (4.6m).
Clearance to a service regulator vent outlet.
12” (30.5cm)
6’ (1.8m)
7’ (2.1m) ‡
9” (22.9cm)
3’ (0.9m) †
Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other appliance.
Clearance to a mechanical air supply inlet.
7’ (2.1m) **** Clearance above a paved sidewalk or paved driveway located on public property.
M 12” (30.5cm)†† 12” (30.5cm)**** Clearance under a veranda, porch or deck.
N
O
P
Q
R
**
***
****
†
‡
††
†*
S
Δ
*
16” (40.6cm)
2’ (0.6m)†*
8’ (2.4m)
16” (40.6cm) Clearance above the roof.
2’ (0.6m) †*
8’ (2.4m)
Clearance from an adjacent wall including neighbouring buildings.
Roof must be non -combustible without openings.
3’ (0.9m)
6’ (1.8m)
3’ (0.9m)
6’ (1.8m)
See chart for wider wall dimensions.
See chart for deeper wall dimensions. The terminal shall not be installed on any wall that has an opening between the terminal and the open side of the structure.
12” (30.5cm) Clearance under a covered balcony 12” (30.5cm)
The terminal shall not be located less than 6 feet under a window that opens on a horizontal plane in a structure with three walls and a roof.
Recommended to prevent condensation on windows and thermal breakage
It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits.
The periscope requires a minimum 18 inches clearance from an inside corner.
This is a recommended distance. For additional requirements check local codes.
3 feet above if within 10 feet horizontally.
A vent shall not terminate where it may cause hazardous frost or ice accumulations on adjacent property surfaces.
Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the floor.
Recommended to prevent recirculation of exhaust products. For additional requirements check local codes.
††* Permitted only if the balcony is fully open on a minimum of one side.
NOTE: Clearances are in accordance with local installation codes and the requirements of the gas supplier.
W415-1606 / 09.09.16
EN
12
3.5 VENTING APPLICATION FLOW CHART
REAR EXIT
Horizontal Termination
Vertical rise is equal to or greater than the horizontal run
Vertical rise is less than horizontal run
Vertical Termination
Vertical rise is equal to or greater than the horizontal run
Vertical rise is less than horizontal run
Horizontal run + vertical rise to maximum of 40 feet
(12m)
Horizontal run + vertical rise to maximum of
24.75 feet (7.5m)
3.5 times the vertical rise equal to or greater than the horizontal run
Horizontal run + vertical rise to maximum of 40 feet
(12m)
Horizontal run + vertical rise to maximum of 40 feet
(12m)
13.2A
3 times the vertical rise equal to or greater than the horizontal run
3.6 DEFINITIONS
For the following symbols used in the venting calculations and examples are:
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
H
T
- total of both horizontal vent lengths (Hr) and offsets (Ho) in feet
H
R
H
O
V
- combined horizontal vent lengths in feet
- offset factor: .03 (total degrees of offset - 90°*) in feet
T
- combined vertical vent lengths in feet
14.1
3.7 ELBOW VENT LENGTH VALUES
1°
FEET INCHES
0.03 0.5
15° 0.45 6.0
30° 0.9 11.0
45° 1.35 16.0
90°* 2.7 32.0
MILLIMETERS
12.7
152.4
279.4
406.4
812.8
* The fi rst 90° offset has a zero value and is shown in the formula as - 90°
15.1A
W415-1606 / 09.09.16
13
3.8 HORIZONTAL TERMINATION
Simple venting configuration
(only two 90° elbows)
(H
T
) < (V
T
)
See graph to determine the required vertical rise V
T horizontal run H
T
.
for the required
40 (12.2)
38.3 (11.7)
REQUIRED
VERTICAL
RISE IN
FEET
(METERS) V
T
30 (9.1)
20 (6.1)
10 (3.1)
1.6 (0.5)
0
1.6
(0.5)
2.5
(0.8)
5
(1.5)
7.5
(2.3)
10
(3.1)
12.5
(3.8)
15
(4.6)
17.5
(5.3)
20
(6.1)
HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H
T
The shaded area within the lines represents acceptable values for H
T and H
T
EN
For vent configurations requiring more than two 90° elbows, the following formulas apply:
Formula 1: H
T
< V
T
Formula 2: H
T
+ V
T
< 40 feet (12.2m)
V
V
Example:
V
1
= 9 FT (2.7m)
H
2
T
1
= 6 FT (1.8m)
= V
1
+ V
2
= 9FT (2.7m) + 6FT (1.8m) = 15FT (4.6m)
H
2
= 3 FT (0.9m)
= 2 FT (0.6m)
H
3
H
H
O
H
T
H
R
T
= 1.5 FT (0.5m)
= H
= .03 (four 90° elbows - 90°) = .03 (360° - 90°) = 8.1 FT (2.5m)
= H
+ V
1
R
T
+ H
+ H
2
+ H
3
= 3FT (0.9m) + 2FT (0.6m) + 1.5FT (0.5m) = 6.5FT (2m)
O
= 6.5FT (2m) + 8.1FT (2.5m) = 14.6FT (4.5m)
= 14.6FT (4.5m) + 15FT (4.6m) = 29.6 FT (9m)
Formula 1: H
T
< V
T
14.6 FT (4.5m) < 15 FT (4.6m)
Formula 2: H
T
+ V
T
< 40 FT (12.2m)
29.6 FT (9m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
H
1
V
1
90°
90°
V
2
H
2
90°
H
3
90°
16.3A
W415-1606 / 09.09.16
14
EN
Simple venting configuration
(only two 90° elbows)
(H
T
) > (V
T
)
See graph to determine the required vertical rise V
T required horizontal run H
T
.
for the
12.5 (3.8)
12.25 (3.7)
REQUIRED
VERTICAL RISE IN
FEET
(METERS) V
T
8.3 (2.54)
5.5
(1.68)
4.2 (1.3)
1
(0.3)
0
1
(0.3)
2.5
(0.8)
3.5
(1.1)
5
(1.5)
7.5
(2.3)
10
(3.1)
12.5
(3.8)
15
(4.6)
17.5
(5.3)
20
(6.1)
19.25
(5.9)
HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H
T
The shaded area within the lines represents acceptable values for H
T and H
T
For vent configurations requiring more than two 90° elbows, the following formulas apply:
Formula 1: H
T
< 3.5V
T
Formula 2: H
T
+ V
T
< 24.75 feet (7.5m)
Example:
V
1
= 4 FT (1.2m)
V
V
H
H
H
H
H
H
2
T
1
2
3
4
R
O
= 1.5 FT (0.5m)
= V
1
+ V
2
= 4FT (1.2m) + 1.5FT (0.5m) = 5.5 FT (1.7m)
= 2 FT (0.6m)
= 1 FT (0.3m)
= 1 FT (0.3m)
= 1.5 FT (0.5m)
= H
1
+ H
2
+H
3
+H
4
= 2FT(0.6m) + 1FT(0.3m) + 1FT(0.3m) + 1.5FT(0.5m) = 5.5 FT(1.7m)
= .03 (four 90° elbows + one 45° elbow - 90°)
= .03 (90 + 90 + 90 + 90 + 45 - 90) = 9.45 FT (2.9m)
H
T
= H
R
+ H
H
T
+ V
T
O
= 5.5FT (1.7m) + 9.45FT (2.9m) = 14.95FT (4.6m)
= 14.95FT (4.6m) + 5.5FT (1.7m) = 20.45FT (6.2m)
Formula 1:
Formula 2:
H
T
< 3.5V
T
3.5V
T
= 3.5FT (1.1m) x 5.5FT (1.7m) = 19.25FT (5.9m)
14.95 FT (4.6m) < 19.25 FT (5.9m)
H
T
+ V
T
< 24.75 FT (7.5m)
20.45 FT (6.2m) < 24.75 FT (7.5m)
Since both formulas are met, this vent configuration is acceptable.
H
1
V
1
90°
V
2
H
90°
90°
2
H
3
90°
16.3_2C
W415-1606 / 09.09.16
15
3.9 VERTICAL TERMINATION
Simple venting configurations.
(H
T
) < (V
T
)
See graph to determine the required vertical rise V
T required horizontal run H
T
.
for the
40 (12.2)
EN
30 (9.1)
REQUIRED
VERTICAL
RISE IN FEET
(METERS) V
T
20 (6.1)
10 (3.1)
3 (0.9)
0 5
(1.5)
10
(3.1)
15
(4.6)
20
(6.1)
HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H
T
The shaded area within the lines represents acceptable values for H
T and V
T
For vent configurations requiring more than one 90° elbow, the following formulas apply:
Formula 1: H
T
< V
T
Formula 2: H
T
+ V
T
< 40 feet (12.2m)
Example:
V
1
= 5 FT (1.5m)
V
V
H
H
H
H
2
T
1
2
R
O
= 10 FT (3.1m)
= V
= H
1
+ V
1
2
= 5FT (1.5m) + 10FT (3.1m) = 15 FT (4.6m)
= 3 FT (0.9m)
= 2.5 FT (0.8m)
+ H
2
= 3FT (0.9m) + 2.5FT (0.8m) = 5.5 FT (1.7m)
= .03 (three 90° elbows - 90°)
= .03 (270° - 90°) = 5.4 FT (1.6m)
H
H
T
T
= H
R
+ H
+ V
T
O
= 5.5FT (1.7m) + 5.4FT (1.6m) = 10.9 FT (3.3m)
= 10.9 FT (3.3m) + 15 FT (4.6m) = 25.9 FT (7.9m)
Formula 1:
Formula 2:
H < V
10.9 FT (3.3m) < 15 FT (4.6m)
H
T
+ V
T
< 40 FT (12.2m)
25.9 FT (7.9m) < 40 (12.2m)
Since both formulas are met, this vent configuration is acceptable.
H
1
90°
V
1
H
2
V
2
90°
18.6A
90°
W415-1606 / 09.09.16
EN
16
Simple venting configurations.
(H
T
) > (V
T
)
See graph to determine the required vertical rise V
T required horizontal run H
T
.
for the
REQUIRED
VERTICAL
20 (6.1)
19 (5.8)
10 (3.1) RISE IN
FEET
(METERS) V
T
3 (0.9)
0 5
(1.5)
10
(3.1)
15
(4.6)
20
(6.1)
25
(7.6)
30
(9.1)
HORIZONTAL VENT RUN PLUS OFFSET IN
FEET (METERS) H
T
The shaded area within the lines represents acceptable values for H
T and v
T
For vent configurations requiring more than one 90° elbow, the following formulas apply:
Formula 1: H
T
< 3 V
T
Formula 2: H
T
+ V
T
< 40 FT (12.2m)
Example:
V
1
= 1.5 FT (0.5m)
V
V
H
H
H
H
H
2
T
1
2
3
R
O
= 5 FT (1.5m)
= V
1
+ V
2
= 1.5FT (0.5m) + 5FT (1.5m) = 6.5 FT (2m)
= 1 FT (0.3m)
= 1 FT (0.3m)
= 10.75 FT (3.3m)
= H
2
+ H
3
= .03 (270° + 45° - 90°) = 6.75 FT (2.1m)
H
H
T
T
1
+ H = 1FT (0.3m) + 1FT (0.3m) + 10.75FT (3.3m) = 12.75 FT (3.9m)
= .03 (three 90° elbows + one 45° elbow - 90°)
= H
+ V
R
T
+ H = 12.75FT (3.9m) + 6.75FT (2.1m) = 19.5 FT (5.9m)
90°
H
2
Formula 1:
H
T
< 3 V
3 V
T
T
= 3FT (0.9m) x 6.5FT (2m) = 19.5FT (5.9m)
19.5FT (5.9m) = 19.5FT (5.9m) H
1
V
1
90°
Formula 2:
H
T
+ V
T
< 40 FT (12.2m)
26 FT (7.9m) < 40 FT (12.2m)
45°
H
3
V
2
90°
Since both formulas are met, this vent configuration is acceptable.
18.7A
W415-1606 / 09.09.16
4.0 INSTALLATION
!
WARNING
DO NOT CLAMP THE FLEXIBLE VENT PIPE.
68.2D
4.1 WALL AND CEILING PROTECTION
!
WARNING
DO NOT FILL THE SPACE BETWEEN THE VENT PIPE AND ENCLOSURE WITH ANY TYPE OF
MATERIAL. DO NOT PACK INSULATION OR COMBUSTIBLES BETWEEN CEILING FIRESTOPS.
ALWAYS MAINTAIN SPECIFIED CLEARANCES AROUND VENTING AND FIRESTOP SYSTEMS.
INSTALL WALL SHIELDS AND FIRESTOPS AS SPECIFIED. FAILURE TO KEEP INSULATION OR
OTHER MATERIALS AWAY FROM VENT PIPE MAY CAUSE FIRE.
70.1
17
EN
W415-1606 / 09.09.16
EN
18
4.2 MOUNTING PLATE INSTALLATION
C.
D.
E.
A.
B.
F.
G.
H.
Level and affix the mounting template to the wall at the desired location and height. The centre of the vent pipe must be centered between wall studs.
Using the template, mark the holes for the vent, gas and electrical outlets, and mounting screw locations. See “MINIMUM CLEARANCES TO COMBUSTIBLES” section. NOTE : Choose the appropriate screws required for either combustible or non-combustible material. A minimum of four screws must be used to mount appliance into wall studs.
Remove the mounting template from the wall and cut/drill the required holes as marked.
Screw the vent shield together using the screws provided (Fig. 1).
Bend the 4 tabs on the firestop spacer outwards. Slide the vent shield into the firestop spacer aligning the holes within the tabs. Using 4 of the screws provided, secure the vent shield to the firestop spacer
(Fig. 2).
The vent shield and firestop spacer have been designed to accommodate a maximum wall depth of
14" (35.6cm). The vent shield must extend the full depth of the combustible wall. Trim the vent shield to suit as necessary.
Apply a bead of caulking (not supplied) to the flange perimeter and wings of the firestop spacer. Insert the firestop spacer with mounted vent shield into the wall and level the firestop spacer. Once leveled, secure firestop spacer to the wall using 4 fasteners (Fig. 3).
Install mounting plate by aligning dimples on firestop spacer and secure using four screws provided.
(Fig. 4)
WALL
W415-1606 / 09.09.16
CAULKING
FIG.1
REAR VIEW
FIG.3
FIG.2
FIG.4
FIG.5
I.
J.
19
Look through slotted holes on the mounting plate for pre-marked stud locations and secure mounting plate using a minimum of 4 screws (minimum 1 screw per corner must be mounted to a wall stud) (Fig. 5).
See the following sections up to the
“FINISHING” section for venting and mounting instructions.
EN
4.3 USING FLEXIBLE VENT COMPONENTS
!
WARNING
DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS.
KEEP IT PULLED TIGHT.
SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN
AIR GAP TO THE OUTER FLEX PIPE. THIS GAP IS REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED
AT THE START, MIDDLE AND END OF EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS
MUST NOT BE REMOVED.
ELBOW
SPACERS
For safe and proper operation of the appliance, follow the venting instructions exactly.
All inner fl ex pipe and outer fl ex pipe joints may be sealed using high temperature red RTV silicone W573-0002 (not supplied) or the high temperature sealant W573-0007 Mill Pac (not supplied). However, the high temperature sealant W573-0007 Mill Pac (not supplied) must be used on the joint connecting the inner fl ex pipe and the exhaust fl ue collar.
Use only approved fl exible vent pipe kits marked:
“Wolf Steel Approved Venting” as identifi ed by the stamp only on the outer fl ex pipe.
22.1A
4.3.1 APPLIANCE VENT CONNECTION
A. Install the inner fl ex pipe to the fi replace. Secure with a minimum 3 screws and fl at washers. Seal the joint and screw holes using Mill Pac sealant (W573-0007) (not supplied).
B. Install the outer fl ex pipe to the fi replace. Secure with a minimum of 3 screws and fl at washers. Seal the joints using red RTV silicone (W573-0002) (not supplied).
1 1/2” OVERLAP
(38.1mm)
SCREWS
28.4B
HIGH
TEMPERATURE
SEALANT
W415-1606 / 09.09.16
EN
20
4.3.2 VERTICAL INSTALLATION
This application occurs when venting through a roof. Installation kits for various roof pitches are available from your authorized dealer / distributor.
See accessories to order specifi c kits required.
A.
Determine the air terminal location, cut and frame a square opening as illustrated in the ceiling and the roof to provide the minimum 1" (25mm) clearance between the vent pipe and any combustible material. Try to center the vent pipe location midway between two joists to prevent having to cut them. Use a plumb bob to line up the center of the openings. A vent pipe shield will prevent any materials such as insulation, from fi lling up the 1" (25mm) air space around the pipe.
Nail headers between the joist for extra support.
8”
FIRESTOP
UNDERSIDE OF
JOIST
8”
B. Apply a bead of caulking (not supplied) to the framework or to the
Wolf Steel vent pipe shield plate or equivalent (in the case of a fi nished ceiling), and secure over the opening in the ceiling. A fi restop must be placed on the bottom of each framed opening in a roof or ceiling that the venting
VENT PIPE
SHIELD system passes through. Apply a bead of caulking all around and place a fi restop spacer over the vent shield to restrict cold air from being drawn into the room or around the fi replace. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe is installed in its fi nal position, apply
Mill Pac sealant (W573-0007) (not supplied) or red RTV silicone (W573-0002) (not supplied) between the pipe and the fi restop assembly.
CAULKING
VENT
PIPE
SHIELD
C.
In the attic, slide the vent pipe collar down to cover up the open end of the shield and tighten. This will prevent any materials, such as insulation, from fi lling up the 1" (25mm) air space around the pipe.
VENT
PIPE
COLLAR
21.1B
4.3.3 HORIZONTAL AIR TERMINAL INSTALLATION
A.
B.
C.
Stretch the inner fl ex pipe to the required length taking into account the additional length needed for the fi nished wall surface. Apply a heavy bead of the Mill Pac sealant
(W573-0007) (not supplied) to the inner sleeve of the air terminal. Slip the vent pipe a minimum of 2”
(50.8mm) over the inner sleeve of the air terminal and secure with a minimum of 3 #8 screws.
Using the outer fl ex pipe, slide over the outer combustion air sleeve of the air terminal and secure with a minimum of 3 #8 screws. Seal using red RTV silicone
(W573-0002) (not supplied).
Insert the vent pipes through the fi restop maintaining the required clearance to combustibles. Holding the air terminal
(lettering in an upright, readable position), secure to the exterior wall and make weather tight by sealing with caulking (not supplied).
HI-TEMP
SEALANT
CAULKING
OUTER FLEX PIPE
2" (50.8mm) OVERLAP
HIGH TEMPERATURE
SEALANT
#8 X 1/2” SELF DRILLING
SCREWS
D.
If more vent pipe needs to be used to reach the fi replace, couple them together as illustrated. The vent system must be supported approximately every 3 feet (0.9m) for both vertical and horizontal runs. Use noncombustible strapping to maintain the minimum clearance to combustibles.
OUTER
FLEX PIPE
INNER
FLEX PIPE
OUTER
FLEX PIPE
The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the depth of its return fl ange.
23.1C
HI-TEMP
SEALANT
W415-1606 / 09.09.16
B.
C.
D.
E.
F.
G.
H.
21
4.3.4 VERTICAL AIR TERMINAL INSTALLATION (FLEXIBLE)
!
WARNING
MAINTAIN A MINIMUM 2” (51mm) SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR.
A.
Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
Stretch the inner fl ex pipe to the required length. Slip the inner fl ex pipe a minimum of 2” (51mm) over the inner pipe of the air terminal connector and secure with a minimum of
3 #8 screws. Seal using a heavy bead of Mill Pac sealant
(W573-0007) (not supplied).
Repeat using the outer fl ex pipe, using a heavy bead of red RTV silicone (W573-0002) (not supplied) and a minimum of 3 #8 screws.
ROOF SUPPORT
Thread the air terminal connector / vent pipe assembly down through the roof. The air terminal must be positioned vertically and plumb.
Attach the air terminal connector to the roof support, ensuring that the top of the air terminal is 16” (406mm) above the highest point that it penetrates the roof.
AIR
TERMINAL
INNER PIPE
Remove nails from the shingles, above and to the sides of the air terminal connector. Place the fl ashing over the air terminal connector
CONNECTOR
MILL PAC
SEALANT
(W572-0007) leaving a min. 3/4” (19mm) of the air terminal connector showing above the top of the fl ashing. Slide the fl ashing underneath the sides and upper edge of the shingles. Ensure that the air terminal connector is properly centered within the fl ashing, giving a 3/4”
(19mm) margin all around. Fasten to the roof. Do not nail through the lower portion of the fl ashing. Make weather-tight by sealing with caulking. Where possible, cover the sides and top edges of the fl ashing with roofi ng material.
INNER FLEX PIPE
OUTER FLEX PIPE
Aligning the seams of the terminal and air terminal connector, place the terminal over the air terminal connector making sure the vent pipe goes into the hole in the terminal. Secure with the three screws provided.
Apply a heavy bead of weatherproof caulking 2” (51mm) above the fl ashing. Install the storm collar around the air terminal and slide down to the caulking. Tighten to ensure that a weather-tight seal between the air terminal and the collar is achieved.
If more vent pipe needs to be used to reach the appliance see
“HORIZONTAL AIR TERMINAL INSTALLATION” section.
2” (51mm) AIR INLET
BASE
CAULKING
STORM COLLAR
WEATHER
SEALANT
FLASHING
24.1C
EN
W415-1606 / 09.09.16
22
EN
4.3.5 HORIZONTAL AIR TERMINAL INSTALLATION
!
WARNING
RISK OF FIRE, DO NOT ALLOW LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE.
REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO MAINTAIN
CLEARANCES TO COMBUSTIBLES.
A.
B.
C.
Move the appliance into position. Measure the vent length required between terminal and appliance taking into account the additional length needed for the fi nished wall surface and any
1¼” (31.8mm) overlaps between venting components.
CAULKING
Apply high temperature sealant W573-0007
(not supplied) to the outer edge of the inner collar of the appliance. Attach the fi rst inner rigid pipe component and secure using 3 self tapping screws.
Repeat using the outer rigid pipe.
PIPE
SELF DRILLING
Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall and make weather tight by sealing with caulking (not supplied).
The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the depth of the return fl ange.
26.4A
4.3.6 EXTENDED HORIZONTAL AND CORNER TERMINAL INSTALLATION
A 45° corner installation can have 0” (0mm) rise between the appliance combustion air collar and the air terminal. In this case, vent lengths must be kept to a maximum of 24” (609.6mm) . For longer vent lengths, a minimum vertical rise of 24” (609.6mm) is required.
AIR TERMINAL
TELESCOPIC SLEEVE
A.
Follow the instructions for "HORIZONTAL AIR TERMINAL
INSTALLATION" section.
20" (508mm)
COUPLER
B. Continue adding components alternating inner and outer vent pipes. Ensure that
all inner vent pipes and elbows have sufficient vent spacers attached and each
component is securely fastened to the one prior. Attach the telescopic sleeve to the
vent run. Secure and seal. To facilitate completion, attach inner and outer couplers to
the air terminal.
VENTING
C.
Install the air terminal. See “HORIZONTAL AIR TERMINAL INSTALLATION” section. Extend the outer
telescopic sleeve; connect to the air terminal assembly. Fasten with self tapping screws and seal.
48.2A
W415-1606 / 09.09.16
4.4 MOUNTING THE WHD48
A.
Guide the vent pipe through the shield on the mounting plate and secure the appliance to the mounting plate as illustrated using 8 screws.
VENT SHIELD
23
EN
MOUNTING PLATE
W415-1606 / 09.09.16
EN
24
4.5 GAS INSTALLATION
!
WARNING
SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT
WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE
PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT
THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND
ELECTRICAL LOCATIONS, SEE “DIMENSIONS” SECTION.
ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.
VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.
Installation and servicing to be done by a qualifi ed installer.
•
•
•
•
•
•
Move the appliance into position and secure.
If equipped with a fl ex connector the appliance is designed to accept a 1/2” (13mm) gas supply.
Without the connector it is designed to accept a 3/8” (9.5mm) gas supply. The appliance is equipped with a manual shut off valve to turn off the gas supply to the appliance.
Connect the gas supply in accordance to local codes. In the absence of local codes, install to the current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI
Z223.1 / NFPA 54 in the United States.
When fl exing any gas line, support the gas valve so that the lines are not bent or kinked.
The gas line fl ex-connector should be installed to provide suffi cient movement for shifting the burner assembly on its side to aid with servicing components.
Check for gas leaks by brushing on a soap and water solution. Do not use open fl ame.
30.1A
4.6 MOBILE HOME
This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. Built in appliances are equipped with 1/4” diameter holes located in the front left and right corners of the base. Use #10 hex head screws, inserted through the holes in the base to secure. For free standing products contact your local authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must be fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the appliance, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another consult your Authorized dealer/distributor.
29.6A
W415-1606 / 09.09.16
4.7 MINIMUM CLEARANCE TO COMBUSTIBLES AND NON-COMBUSTIBLES
-
-
MINIMUM CLEARANCE TO COMBUSTIBLE CONSTRUCTION FROM APPLIANCE AND VENT
SURFACES:
-
1/2" (13mm) to wall mounting plate
1" (2.5cm) to bottom and sides of vent pipe*
3" (7.6cm) to top of vent pipe*
MINIMUM CLEARANCES TO COMBUSTIBLES (FROM THE APPLIANCE):
- 15" (38.1cm) to top/ceiling
- 7" (17.8cm) to sides
- 6” (15.2cm) to bottom
- 1/2" (13mm) to rear
* A minimum of 1" (25mm) all around the vent pipe on all vertical runs to combustibles is required.
25
EN
(17.8 cm)
MIN.
(17.8 cm)
MIN.
36"
MAX.
ALCOVE
INSTALLATION
TOP VIEW
4.5" (11.4 cm) MIN.
(91.4cm)
MAX.
6" (15.2 cm) MIN.
ALCOVE
INSTALLATION
SIDE VIEW
4.5" (11.4 cm) MIN.
6" (15.2 cm) MIN.
TYPICAL
INSTALLATION
W415-1606 / 09.09.16
EN
26
5.0 FINISHING
!
WARNING
RISK OF FIRE!
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS
REMOVED, CRACKED, BROKEN OR SCRATCHED.
72.4
5.1 HOUSING PANEL INSTALLATION
A.
Secure the housing panels as illustrated using the 16 #8 x 1/2” pan head screws and 10 #9 x 1/2” 1/4” hex head screws supplied.
- 5 #9 hex head screws secure the top housing panel. (Step 1)
- 5 #9 hex head screws secure the bottom housing panel. (Step 2)
- 8 #8 pan head screws secure each of the side housing panels. (Steps 3 & 4)
1
2
3
W415-1606 / 09.09.16
NOTE : DO NOT PINCH WIRES.
4
27
5.2 DOOR REMOVAL / INSTALLATION
!
WARNING
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.
IF EQUIPPED WITH DOOR LATCHES THAT ARE PART OF A SAFETY RELIEF SYSTEM, THEY MUST BE
PROPERLY ENGAGED. DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED.
FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR
OPENINGS, LOUVRE OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR
SERVICE. OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS.
BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TO
THE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE.
75.1A
A.
Remove the surround with safety screen.
(see “SURROUND INSTALLATION /
REMOVAL” section).
B.
Remove the 5 screws that secure the door.
C.
D.
Lift the door up and off.
THIS WARNING FOR ELECTRICS ONLY:
Reverse steps to reinstall the door and safety screen with surround.
burns from the hot viewing glass is provided with the appliance and must be installed.
!
WARNING
EN
!
WARNING
THE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE.
75.1
DO NOT CHANGE OR SUBSTITUTE THE GLASS MEDIA MATERIAL PROVIDED WITH THIS APPLIANCE. IF
REPLACING, USE ONLY THE REPLACEMENT GLASS MEDIA AVAILABLE FROM YOUR AUTHORIZED
DEALER / DISTRIBUTOR.
GLASS MEDIA OVER THE BURNER MUST NOT BE MORE THAN ONE LAYER HIGH. MORE THAN ONE LAYER
OVER THE BURNER WILL CAUSE FLAME LIFTING AND SOOTING PROBLEMS.
DO NOT PLACE ANY MEDIA (GLASS OR VERMICULITE) IN OR AROUND THE PILOT OPENING. THIS WILL
INTERFERE WITH THE PILOT OPERATION.
Evenly spread the glass media onto the media tray, covering the burner tube and tray.
Glass media over the burner ports may cause a “Puffi ng” sound. To eliminate this sound, simply push the media away from the burner ports.
NOTE: The distribution of glass media over the burner ports will infl uence the fl ame height. When the fl ames impinge on the glass, the glass may discolour slightly and the edges may soften.
NOTE: Do not use more media than what was supplied with the appliance.
CLEANING GLASS MEDIA
Glass media may have a fi ne oil residue that needs to be cleaned prior to installation. Clean the glass with mild dish soap, drain, rinse thoroughly and dry before placing over the burner.
74.1C
W415-1606 / 09.09.16
EN
28
5.4 SURROUND INSTALLATION / REMOVAL
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and must be installed.
A.
Lift the surround and slide the hooks into the slots on the appliance, then let it slide down into position.
NOTE: When installing the surround, ensure no wires are pinched or exposed.
SAFETY BARRIER
HOOKS
SLOTS
5.5 LOGO PLACEMENT
SAFETY BARRIER
1/2"
(12.7mm) LOGO
1/2" (12.7mm)
1/2"
(12.7mm) LOGO
1/2" (12.7mm)
W415-1606 / 09.09.16
ÉCRAN DE PROTECTION
29
6.0 OPTIONAL INSTALLATION
6.1 RECEIVER LOCATION/WIRING
A.
For wiring information see the “WIRING DIAGRAM” section.
Remote receiver can either be installed into the side of the appliance (see illustration below) or hard wired into a wall within 8 feet of the appliance and must be accessible for programming the remote.
If installing into a wall, install the receiver into a standard electrical switch box. Determine an appropriate location and install the electrical box.
NOTE: Ensure the 3 position slider switch is in the “REMOTE” position (middle).
EN
W415-1606 / 09.09.16
EN
30
7.0 ELECTRICAL INFORMATION
7.1 HARD WIRING CONNECTION
It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian electrical code in Canada or the ANSI/NFPA 70-1996
National electrical code in the United States.
7.2 WIRING DIAGRAM
!
WARNING
DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH.
This appliance comes equipped with a battery back-up. If this backup is used install four AA batteries (not supplied) into the holder and connect to the wire harness. The connection point resembles a 9 volt battery type of terminal, however, a 9 bolt battery must not be connected.
PILOT
OPTIONAL
(NOT SUPPLIED)
BATTERY HOLDER COMPLETE
WITH RESET BUTTON RESET
BUTTON
W415-1606 / 09.09.16
W190-0048 (RECEIVER)
* BLOWER (NOT
AVAILABLE WITH THIS
APPLIANCE)
8.0 OPERATION
!
WARNING
When lit for the first time, the appliance will emit a slight odour for a few hours. This is a normal temporary condition caused by the “burn-in” of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room. After extended periods of nonoperation such as following a vacation or a warm weather season, the appliance may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.
8.1 OPERATING INSTRUCTIONS
C
OPERATING INSTRUCTIONS / INSTRUCTIONS D’OPERATION
FOR YOUR SAFETY READ BEFORE OPERATING / POUR VOTRE SÉCURITÉ LIRE AVANT DE FAIRE FONCTIONNER
WARNING: DO NOT TURN ON IF CHILDREN OR OTHER AT RISK
INDIVIDUALS ARE NEAR THE FIREPLACE. IF YOU DO NOT FOLLOW THESE
INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
INITIAL LIGHTING OF THE PILOT AND MAIN BURNERS MUST BE DONE
WITH THE GLASS DOOR OFF.
DO NOT CONNECT VALVE OR WALL SWITCH TO ELECTRICITY. SEE
INSTALLATION INSTRUCTIONS.
ATTENTION: NE PAS ALLUMER SI DES ENFANTS OU D’AUTRES
INDIVIDUS À RISQUE SONT À PROXIMITÉ DU FOYER. QUICONQUE NE
RESPECTE PAS À LA LETTRE LES INSTRUCTIONS DANS LA PRÉSENTE
NOTICE RISQUE DE DÉCLENCHER UN INCENDIE OU UN EXPLOSION
ENTRAÎNANT DES DOMMAGES, DES BLESSURES OU LA MORT.
L’ALLUMAGE INITIAL DE LA VEILLEUSE ET DU BRÛLEUR PRINCIPAL
DOIT SE FAIRE AVEC LA PORTE VITRÉE ENLEVÉE.
NE RACCORDEZ PAS LA SOUPAPE OU L’INTERRUPTEUR MURAL A
L’ÉLECTRICITÉ. CONSULTEZ LES INSTRUCTIONS D’INSTALLATION.
A. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY
LIGHTS THE PILOT. DO NOT TRY TO LIGHT BY HAND.
B. BEFORE OPERATING SMELL ALL AROUND THE FIREPLACE AREA FOR GAS AND NEXT TO
THE FLOOR BECAUSE SOME GAS IS HEAVIER THAN AIR AND WILL SETTLE ON THE
FLOOR.
WHAT TO DO IF YOU SMELL GAS:
• TURN OFF ALL GAS TO THE FIREPLACE.
• OPEN WINDOWS.
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING.
• IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOUR’S PHONE. FOLLOW THE
GAS SUPPLIER’S INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.
C. DO NOT TRY TO REPAIR ANY PART OF THIS ASSEMBLY. CALL A QUALIFIED SERVICE
TECHNICIAN. FORCE OR ATTEMPTED REPAIR MAY RESULT IN A FIRE OR EXPLOSION.
D. DO NOT USE THIS FIREPLACE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY
CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE FIREPLACE AND REPLACE
ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER
WATER.
A. CET APPAREIL EST MUNI D’UN DISPOSITIF D’ALLUMAGE QUI ALLUME
AUTOMATIQUEMENT LA VEILLEUSE. NE TENTEZ PAS D’ALLUMER LA VEILLEUSE
MANUELLEMENT.
B. AVANT DE FAIRE FONCTIONNER, RENIFLEZ TOUT AUTOUR DE L’APPAREIL POUR
DÉCELER UN ODEUR DE GAZ. RENIFLEZ PRÈS DU PLANCHER, CAR CERTAINS GAZ
SONT PLUS LOURDS QUE L’AIR ET PEUVENT S’ACCUMULER AU NIVEAU DU SOL.
QUE FAIRE SI VOUS DÉTECTEZ UNE ODEUR DE GAZ:
• COUPEZ L’ALIMENTATION DE GAZ PRINCIPALE.
• OUVREZ LES FENETRES.
• NE PAS TENTER D’ALLUMER D’APPAREIL.
• NE TOUCHEZ À AUCUN INTERRUPTEUR; NE PAS VOUS SERVIR DES TÉLÉPHONES SE
TROUVANT DANS LE BÂTIMENT.
• APPELEZ IMMÉDIATEMENT VOTRE FOURNISSEUR DE GAZ DEPUIS UN VOISIN.
SUIVEZ LES INSTRUCTIONS DU FOURNISSEUR.
• SI VOUS NE POUVEZ REJOINDRE LE FOURNISSEUR APPELEZ LE SERVICE DES
INCENDIES.
C. N’ESSAYEZ PAS DE RÉPARER AUCUNE PIÈCE DE CET ASSEMBLAGE. APPELEZ UN
TECHNICIEN QUALIFIÉ. FORCER OU TENTER DE RÉPARER L’ASSEMBLAGE POURRAIT
CAUSER UN FEU OU UNE EXPLOSION.
D. N’UTILISEZ PAS CET APPAREIL S’IL A ÉTÉ PLONGÉ DANS L’EAU, MÊME
PARTIELLEMENT. FAITES INSPECTER L’APPAREIL PAR UN TECHNICIEN QUALIFIÉ ET
REMPLACEZ TOUTE PARTIE DU SYSTÈME DE CONTRÔLE ET TOUTE COMMANDE QUI
ONT ÉTÉ PLONGÉS DANS L’EAU.
W385-0460 / D
D
D
8.2 LIGHTING INSTRUCTIONS
TITLE:
MYLAR WATERPROOF, NON-WATER SOLUABLE ADHESIVE,
CAPABLE OF WITHSTANDING 250° TEMP
SPECIFICATIONS:
RED BORDER ALL AROUND 0.25” RED STRIPE
MAX OVERALL DECAL SIZE:
8.5” X 4.75”
AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT THE PILOT
BY HAND.
OPERATING & LIGHTING INSTRUCTIONS
REVISION: D: CORRECTED FRENCH TO STANDARD
7.
8.
TURN MANUAL SHUTOFF VALVE COUNTER-CLOCKWISE TO ON.
CLOSE THE GLASS DOOR.
(GDS60-1)
|| 11.11.11_CL
INSTRUCTIONS. IF YOU DON’T SMELL GAS GO TO THE NEXT STEP.
9.
10.
TURN ON ALL ELECTRIC POWER TO THE FIREPLACE.
TURN ON MAIN BURNER.
LETTERING:
BLACK ON WHITE BACKGROUND
ALL LETTERING TO BE ARIAL 5.76 PT (0.080” HIGH) WITH 7PT LINE
SPACING EXCEPT FOR TITLES:
“LIGHTING INSTRUCTIONS / INSTRUCTIONS D’ALLUMAGE”,”TO TURN
OF GAS/COUPER L’ALIMENTATION EN GAZ”.
FONCTIONNEMENT ET D’ALLUMAGE AVANT DE CONTINUER.
2.
3.
COUPEZ L’ALIMENTATION ÉLECTRIQUE À L’APPAREIL.
CET APPAREIL EST MUNI D’UN DISPOSITIF D’ALLUMAGE QUI
ALLUME LA VEILLEUSE AUTOMATIQUEMENT, N’ESSAYEZ PAS
D’ALLUMER LA VEILLEUSE MANUELLEMENT.
4.
5.
DROITE A “OFF”.
6.
OUVREZ LA PORTE VITRÉE.
ATTENDEZ CINQ (5) MINUTES POUR QUE LE GAZ PUISSE
LABEL # :
DATE:
W385-0460
03.18.09
S’ÉCHAPPER. SI VOUS DÉTECTEZ UNE ODEUR DE GAZ, ARRÊTEZ!
SUIVEZ « B » DANS LES INSTRUCTIONS DE FONCTIONNEMENT.
S’IL N’Y A PAS D’ODEUR DE GAZ, PASSEZ À L’ÉTAPE SUIVANTE.
7.
TOURNEZ LA SOUPAPE DE SECTIONNEMENT MANUELLE VERS LA
GAUCHE A “ON”.
8.
9.
FERMEZ LA PORTE VITRÉE.
RÉTABLISSEZ L’ALIMENTATION ÉLECTRIQUE AU FOYER.
10. ALLUMEZ LE BRÛLEUR PRINCIPAL.
TO TURN OFF GAS / INSTRUCTIONS POUR COUPER LE GAZ
1.
TURN OFF ALL ELECTRICAL POWER TO THE FIREPLACE IF SERVICE IS
TO BE PERFORMED.
2.
TURN MANUAL SHUTOFF VALVE CLOCKWISE TO OFF. DO NOT
FORCE.
1.
COUPEZ L’ALIMENTATION ÉLECTRIQUE AU FOYER SI UN TRAVAIL
D’ENTRETIEN DOIT SE FAIRE.
2.
TOURNEZ LA SOUPAPE D’ARRÉT MANUELLE VERS LA DROITE
À “OFF” NE FORCEZ PAS.
MATERIAL:
CLASS IIIA-2 PERMANENT LABEL, 6MM THICKNESS TOTAL,
MYLAR WATERPROOF, NON-WATER SOLUABLE ADHESIVE,
CAPABLE OF WITHSTANDING 250° TEMP
SPECIFICATIONS:
RED BORDER ALL AROUND 0.25” RED STRIPE
MAX OVERALL DECAL SIZE:
8.5” X 4.75”
LETTERING:
BLACK ON WHITE BACKGROUND
ALL LETTERING TO BE ARIAL 5.76 PT (0.080” HIGH) WITH 7PT LINE
SPACING EXCEPT FOR TITLES:
“LIGHTING INSTRUCTIONS / INSTRUCTIONS D’ALLUMAGE”,”TO TURN
OF GAS/COUPER L’ALIMENTATION EN GAZ”.
W415-1606 / 09.09.16
TITLE: OPERATING & LIGHTING INSTRUCTIONS (GDS60-1)
REVISION: D: CORRECTED FRENCH TO STANDARD || 11.11.11_CL
PAGE 1 OF 2
LABEL #: W385-0460
DATE: 03.18.09
31
EN
EN
32
8.3 GENERAL TRANSMITTER LAYOUT
Transmission
Key Lock
Low battery alarm
CPI mode
Flame ON
Blower
LED Light
REMOTE
POWER
(ON/OFF)
FUNCTION
ADJUSTMENT
(FLAME HEIGHT, BLOWER
SPEED, LED LIGHT
COLOUR CHANGE)
CYCLE THROUGH
FUNCTIONS
(FLAME, BLOWER AND
LIGHT FUNCTION)
W415-1606 / 09.09.16
33
8.4 INITIALIZING THE TRANSMITTER/BATTERY HOLDER FOR THE FIRST TIME
NOTE: THE INITIALIZING PROCESS MUST BE COMPLETED WITHIN 10 SECONDS OF PRESSING
THE RESET/PROGRAM BUTTON (PRG).
A.
B.
C.
Install the 4 AA batteries into the Proflame 2 battery holder, note the polarity of the batteries and insert as indicated on the cover (+/-).
Ensure the 3 position slider switch is switched to the “REMOTE” position (middle position).
Press the reset/programming button, use a small object such as a paper clip in order to reach the button marked PRG, as shown in the illustration below.
D.
E.
The battery holder will beep 3 times to indicate that it’s ready to synchronize with the transmitter.
Install the 3 AAA batteries into the transmitter, as shown in the photograph below, then press the ON button, The battery holder will beep 4 times to indicate that the transmitter’s command is accepted.
EN
TRANSMITTER
BATTERY HOLDER
SLIDER SWITCH
RESET/PROGRAM
BUTTON (PRG)
8.5 TEMPERATURE DISPLAY
A. With the system in the “OFF” position, press the
Temperature Key and the Mode Key at the same time to change from degrees F to C.
B. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of the
Room Temperature display.
73 °F 23 °C
35.5A
8.6 FLAME HEIGHT TIME
The remote control has six (6) fl ame levels. With the system on and the fl ame level at the maximum, press the Down Arrow Key once and it will reduce the fl ame height by one step until the fl ame is turned off.
The Up Arrow Key will increase the fl ame height each time it is pressed. If the Up Arrow Key is pressed while the system is on but the fl ame is off, the fl ame will come on the high position. A single “beep” will confi rm reception of the command.
76
°F
OFF
FLAME OFF
76
°F
76
°F
FLAME AT LEVEL 1
76
°F
Hi
FLAME AT LEVEL 5
35.8A
FLAME AT “HI” LEVEL 6
W415-1606 / 09.09.16
EN
34
8.7 LED ON/OFF LIGHT CONTROL
NOTE: Optional light kit required for this function.
Light function mode is OFF. Cannot operate light function while in this mode.
Light function mode is ON. Can operate light function while in this mode.
76 °F
NOTE: The remote must be in light function mode to change colours.
A.
76 °F
76
°F
76 is white.
D.
76 °F
76
°F
OFF
°F
76 76
76 76
76 76 °F
°F 76
76 °F
76 °F
Pressing the light function adjustment button up" " to single bar will turn on the LED
76 76 °F
LOCKS ONTO
COLOUR COLOUR
76 °F
76
°F
COLOUR DE BLANC
76 76 °F 76
°F
To lock onto one of the rolling colours. Press the light function adjustment
°F
°F 76
76
VERROUILLE
SUR COULEUR
76
SCROLLS THROUGH
VARIOUS COLOURS
76
76
VERROUILLE
SUR COULEUR
OFF
76 °F 76 °F
76 °F
76
°F
76 °F
°F
76 °F
76
76
°F
76 °F
°F
VERROUILLE
SUR COULEUR
76
76 °F 76 °F
°F
Press the light function adjustment button down
°F
76 76 °F 76 °F
76 °F
76
°F
76 76 °F 76
°F
Press the light function adjustment button down
" " to turn OFF the LED lights.
°F
76
°F
C.
SCROLLS THROUGH
VARIOUS COLOURS
76 76 °F 76 °F
Press the light function adjustment button up " " to single bar and the LED lights
76 76 °F 76 °F seconds of Step B for this function to work.
OFF
NOTE: After the colour has been locked, pressing OFF and ON will start the cycle over with the white colour. If the light is in the OFF position and then back to the ON position, the cycle will begin again
76 76 seconds.
76
76 76 °F 76 °F
OFF
8.7 LED ON/OFF LIGHT CONTROL 8.8 CONTINUOUS PILOT / INTERMITTENT PILOT (CPI / IPI) SELECTION
A.
B.
Use the Mode Key to guide you to the CPI mode icon.
Transmitter in the OFF position.
Press the UP/DOWN to switch between IPI and CPI modes. A single BEEP will confi rm reception of the command.
76
IPI
°F
NOTE: If the system is equipped with a CPI/IPI toggle switch, set the CPI/IPI to CPI position to enable remote CPI operation. If the switch is set to IPI then it will only work in
IPI regardless of what is set on the remote control handset.
76
°F
CPI
35.22
35
EN
8.9 CHILD PROOF FUNCTION
This function will lock the keys to avoid unsupervised operation.
A.
B.
Press the MODE and UP keys at the same time.
To de-activate this function, press the MODE and UP keys at the same time.
35.10A
76 °F
8.10 LOW BATTERY / MANUAL BYPASS
The life span of the remote batteries depends on various factors: quality of the batteries, the number of ignitions, etc.
When the transmitter batteries are low, a battery icon will appear on the LCD display before all battery power is lost. When the batteries are replaced, this icon will disappear.
76 °F
When the receiver batteries are low, no “beep” will be emitted from the receiver when it receives an ON/OFF command. This is an alert for the receiver that there’s low battery. When the batteries are replaced, the “beep” will be emitted from the receiver when the ON/OFF key is pressed.
If the batteries of the receiver or transmitter are low, the appliance can be turned on manually by sliding the three position slider switch on the receiver to the “ON” position. This will bypass the remote control feature and the appliance main burner will come on if the gas valve is in the “ON” position.
35.13A
8.11 IN THE EVENT OF A POWER FAILURE
If the receiver is equipped with batteries they will enable fl ame height control or ON/OFF function to control the fi replace during a power failure. Refer to “APPLIANCE OPERATION” section when communications between receiver and transmitter have been lost. The receiver will emit a “beep” sound to confi rm programming has been successful once power is restored. During a power failure, if the fi replace was on, the fl ame height will stay at the setting prior to the failure. If off when the failure occurs and then turned on, the fl ame height will come on at “HI”. The fl ame height can then be controlled by the remote.
35.14A
W415-1606 / 09.09.16
36
EN
8.12 TIMED BLOWER
NOTE: This function is not available as the appliance is not equipped with a blower.
Your remote system may have a built in timer (in thermostat mode) that enables the blower (if equipped) to cycle on and off automatically when the burner turns on and off. With the remote control fan speed preset at the preferred speed, the blower will come on approximately 5 minutes after the main burner comes on and will shut off approximately 12 minutes after the burner shuts off.
This time delay is designed to maximize the blower distribution of heated air.
If at any time the burner re-ignites before the twelve minutes are over, the fan will continue to run.
NOTE: At any time in the sequence, the blower (if equipped) can be manually turned on/off using the remote control.
35.19B
8.13 MANUAL OPERATION
The appliance can be manually overridden by the remote receiver switch located either on the right side of the appliance or hard wired into the wall. If necessary, change the operation from ‘REMOTE’ by either sliding the switch up to ‘ON’ or down to ‘OFF’.
NOTE : ‘ON’ and ‘OFF’ on the remote receiver only controls the gas.
W415-1606 / 09.09.16
37
9.0 ADJUSTMENTS
9.1 PILOT BURNER ADJUSTMENT
Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.
Check Pressure Readings:
Inlet pressure can be checked by turning screw (A) counterclockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read as described on the chart below. Check pressure with main burner operating on “HI”.
Outlet pressure can be checked the same as above using screw (B). Gauge should read as described on the chart below. Check pressure with main burner operating on “HI”.
AFTER TAKING PRESSURE READINGS, BE SURE TO
TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO
NOT OVERTORQUE.
Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot assembly has not been painted. If overspray or painting of the pilot assembly has occurred remove the paint from the pilot assembly, or replace. Fine emery cloth or a synthetic scrub pad (such as
Scotch-Brite ™) can be used to remove the paint from the pilot hood, electrode and fl ame sensor.
Pressure
Inlet
Natural Gas
(inches)
7" *
(MIN. 4.5")
*Maximum inlet pressure not to exceeed 13”.
Outlet 3.5"
A
FLAME
SENSOR
B
ELECTRODE
Natural Gas
(millibars)
17.4mb
(MIN. 11.2mb)
8.7mb
Propane
(inches)
13"
(MIN. 11")
10"
PILOT SCREW
PILOT
BURNER
FLAME MUST ENVELOP
UPPER 3/8” (9.5mm) TO 1/2”
(12.7mm) OF FLAME SENSOR
Propane
(millibars)
32.4mb
(MIN. 27.4mb)
24.9mb
EN
9.2 VENTURI ADJUSTMENT
This appliance has an air shutter that has been factory set open according to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more yellow flame, but can lead to carbonization. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.
VENTURI
BURNER
ORIFICE
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
49.1
LA FLAMME DOIT
AIR SHUTTER
OPENING
DE FLAMME DE 3/8” (9,5mm)
À 1/2” (12,7mm)
AIR
SHUTTER
OPENING
ORIFICE
VENTURI ADJUSTMENT CHART
FUEL
NG
P
WHD48
1/8" (3mm)
5/16" (7.9mm)
W415-1606 / 09.09.16
EN
38
9.3 FLAME CHARACTERISTICS
It is important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustration provided. If any fl ames appear abnormal, call a service person.
ELECTRODE PILOT
BURNER
3/8” - 1/2”
(9.5mm - 12.7mm)
P
FLAME
SENSOR
54.1B
FLAME MUST ENVELOP
UPPER 3/8” (9.5mm) TO 1/2”
(12.7mm) OF FLAME SENSOR
ÉLECTRODE
VEILLEUSE
NG
LA SONDE
DE FLAMME
LA FLAMME DOIT
ENVELOPPER LA PARTIE
SUPÉRIEURE DE LA SONDE
DE FLAMME DE 3/8” (9,5mm)
À 1/2” (12,7mm)
W415-1606 / 09.09.16
39
10.0 MAINTENANCE
WARNING
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
DO NOT USE ABRASIVE CLEANERS.
DO NOT PAINT THE PILOT ASSEMBLY.
This appliance and its venting system should be inspected before use and at least annually by a qualifi ed service person. The following suggested checks should be performed by a qualifi ed technician. The appliance area must be kept clear and free of combustible materials, gasoline or other fl ammable vapors and liquids. The fl ow of combustion and ventilation air must not be obstructed.
EN
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
A.
B.
In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to expose both assemblies.
Keep the control compartment, media, burner, air shutter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.
C.
D.
E.
F.
G.
H.
I.
J.
Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.
Check to see that the pilot fl ame is large enough to engulf the fl ame sensor and/or thermocouple / thermopile as well as reaches the burner.
Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carbon which can be distributed inside of fi rebox and on exterior surfaces surrounding vent termination.
Check to see that the main burner ignites completely on all openings when turned on. A 5 to 10 second total light-up period is satisfactory. Service as required.
Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.
If for any reason the vent air intake system is disassembled, re-install and re-seal per the instructions provided for the initial installation.
Cleaning the safety barrier may be necessary due to excessive lint / dust from carpeting, pets, etc. simply vacuum using the brush attachment.
Ensure the relief system performs effectively. Check that the gasket is not worn or damaged. Replace if necessary.
40.1E
W415-1606 / 09.09.16
EN
40
10.1 ANNUAL MAINTENANCE
!
WARNING
THE FIREBOX BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE COOL
COMPLETELY OR WEAR HEAT RESISTANT GLOVES BEFORE CONDUCTING SERVICE.
NEVER VACUUM HOT EMBERS.
DO NOT PAINT THE PILOT ASSEMBLY.
• This appliance will require maintenance which should be planned on an annual basis.
• Service should include cleaning, battery replacement, venting inspection and inspection of the burner, media and fi rebox. Refer to the door removal section and remove the door as instructed.
• Carefully remove media if necessary (logs, glass, brick panels etc).
• Using a vacuum with a soft brush attachment, gently remove any dirt, debris or carbon build up from the logs, fi rebox and burner. For glass media, follow the installation instructions for pre-cleaning.
• Also gently remove any build-up on the pilot assembly including, if equipped; thermopile, thermocouple, fl ame sensor and igniter. NOTE: Clean fl ame sensor using a fi ne emery cloth or a synthetic scrub pad
(such as Scotch-Brite™) to remove any oxides. Clean the pilot assembly using a vacuum with a soft brush attachment. It is important that the pilot assembly is not painted.
• Inspect all accessible gaskets and replace as required.
• Access the blower, if equipped and clean using a soft brush and vacuum.
• Re-assemble the various components in reverse order.
• Inspect the relief system. The appliance relieves through the main glass door or through the fl aps on the fi rebox top. Ensure they open freely, and close sealed.
• Check the gas control valve pilot and Hi / Lo knobs move freely (if equipped) – replace if any stiffness in movement is experienced.
• Check for gas leaks on all gas connections up and downstream from the gas valve including the pilot tube connections.
37.1E
10.2 CARE OF GLASS
DO NOT CLEAN GLASS WHEN HOT! DO NOT USE
ABRASIVE CLEANERS TO CLEAN GLASS.
!
WARNING
Buff lightly with a clean dry soft cloth. Clean both sides of the glass after the fi rst 10 hours of operation with a recommended fi replace glass cleaner. Do not use an ammonia-based fi replace glass cleaner. Thereafter clean as required. If the glass is not kept clean permanent discoloration and / or blemishes may result.
This appliance is factory equipped with 5mm ceramic glass. Use only replacement parts as supplied by the appliance manufacturer. DO NOT SUBSTITUTE MATERIALS.
10.3 CARE OF PLATED PARTS
!
5.1A
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
AVERTISSEMENT
LA VITRE CHAUDE CAUSERA
5.5.1A
DES BRÛLURES.
NE PAS TOUCHER LA VITRE
AVANT QU’ELLE AIT REFROIDI.
If the appliance is equipped with plated parts, you must clean fi ngerprints or other marks from the plated surfaces before operating the appliance for the fi rst time. Use a glass cleaner or vinegar and towel to clean.
If not cleaned properly before operating for the fi rst time, the marks can cause permanent blemishes on the plating. After the plating is cured, the fi ngerprints and oils will not affect the fi nish and little maintenance is required, just wipe clean as needed. Prolonged high temperature burning with the door ajar may cause discolouration on plated parts.
NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
6.1
W415-1606 / 09.09.16
10.4 DOOR GLASS REPLACEMENT
!
WARNING
DO NOT USE SUBSTITUTE MATERIALS.
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.
CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR
DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE
APPLIANCE BEFORE OPERATION.
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS
REMOVED, CRACKED, BROKEN OR SCRATCHED.
Replacement glass/frame assembly shall be replaced as a complete unit as supplied by the appliance manufacturer.
56.1C
41
EN
W415-1606 / 09.09.16
EN
42
11.0 REPLACEMENTS
!
WARNING
FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE
ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY
DAMAGE OR PERSONAL INJURY.
** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH
A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE
REQUIRED TO HONOUR THE CLAIM.
When ordering replacement parts always give the following information:
• Model & Serial Number of appliance
• Installation date of appliance
• Part number
• Description of part
• Finish
PARTS, PART NUMBERS AND AVAILABILITY ARE SUBJECT TO CHANGE WITHOUT NOTICE.
PARTS IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN 2 TO 5 BUSINESS DAYS FOR MOST
DELIVERY DESTINATIONS.
PARTS NOT IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN A 2 TO 4 WEEK PERIOD, FOR
MOST CASES.
PARTS IDENTIFIED AS ‘SO’ ARE SPECIAL ORDER AND CAN TAKE UP TO 90 DAYS FOR DELIVERY.
41.1C
W415-1606 / 09.09.16
43
EN
W415-1606 / 09.09.16
EN
44
YES YES
W445-0038 W725-0056
W415-1606 / 09.09.16
45
EN
W415-1606 / 09.09.16
EN
46
13.0 TROUBLESHOOTING
!
WARNING
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,
WITH THE GLASS DOOR OPEN OR REMOVED.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
SYMPTOM
Pilot will not light.
Makes noise with no spark at pilot burner.
SENSOR
IGNITOR
(SPARK)
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
DO NOT USE ABRASIVE CLEANERS.
Wiring.
Module.
PROBLEM
Loose connection.
TEST SOLUTION
Verify the wire for the sensor and the wire for the ignitor are connected to the correct terminals (not reversed) on the module. NOTE: Sensor has 3/16” (4.8mm) connection and ignitor has 1/8” (3.2mm)connection.
Verify no loose connections, electrical shorts in the wiring or ground out to any metal object.
PILOT
TUBE
Turn the ON/OFF switch to the “OFF” position. Remove the igniter wire from the module. Place the ON/OFF switch to the “ON” position. Hold a grounded wire about 3/16”
(4.8mm) away from the ignitor (spark) terminal on the module. If no spark the ignitor terminal module must be replaced. If there is a spark the ignitor terminal is fi ne.
Inspect pilot assembly for a shorted wire or cracked insulator around the electrode.
Igniter Spark gap is incorrect.
Spark gap of the ignitor to the pilot should be 1/8” (3.2mm).
Transformer.
Verify the transformer is installed and plugged into the module. Check voltage of the transformer under load at the spade connections on the module with the ON/OFF switch in the “ON” position. Acceptable readings of a good transformer are between 6.2 and 7.0 volts A.C.
Check batteries.
Battery backup (if power is off)
A shorted or loose
Connection.
Pilot sparks but will not light.
Carbon is being deposited on glass, logs, rocks, media or combustion chamber surfaces.
Improper switch wiring.
Module is not grounded.
Gas supply.
Out of propane gas.
Air shutter has become blocked.
Flame is impinging on the glass, logs, rocks, media or combustion chamber.
Remove and reinstall the wiring harness that plugs into the module. Remove and verify continuity of each wire in wiring harness.
Troubleshoot the system with the simplest ON/OFF switch.
Verify the valve and pilot assemblies are properly grounded to the metal chassis of the appliance or log set.
Verify that the incoming gas line ball valve is “Open”. Verify that the inlet pressure reading is within acceptable limits, inlet pressures must not exceed 13” W.C. (32.3mb).
Fill the tank.
Ensure air shutter opening is free of lint or other obstructions.
-
Check that the glass, logs, rocks or media are correctly positioned.
Too much glass media around the burner can cause carbon deposits.
Open air shutter to increase the primary air.
Check the input rate: check the manifold pressure and orifi ce size as specifi ed by the rating plate values.
Check that the door gasketing is not broken or missing and that the seal is tight.
Check that both vent liners are free of holes and well sealed at all joints.
Check that minimum rise per foot has been adhered to for any horizontal venting.
42.7B
W415-1606 / 09.09.16
SYMPTOM
Continues to spark and pilot lights, but main burner will not light.
PROBLEM
Short or loose connection in sensor rod.
Poor fl ame rectifi cation or contaminated sensor rod.
Poor grounding between pilot assembly and gas valve.
Damaged pilot or dirty sensor rod.
Pilot lights
Stops sparking
/ pilot remains lit but burner will not turn on.
Exhaust fumes smelled in room, headaches.
White / grey fi lm forms.
Flames are very aggressive.
Main burner fl ame is a blue, lazy, transparent fl ame.
Wiring / Connection.
Wiring harness.
Appliance is spilling.
Sulphur from fuel is being deposited on glass, logs or combustion chamber surfaces.
Door is ajar.
Venting action is too great.
Blockage in vent.
Main burner goes out: pilot goes out.
Compromised venting.
Vent recirculation.
47
TEST SOLUTION
Verify all connections. Verify the connections from the pilot assembly are tight; also verify these connections are not grounding out to any metal.
Verify the fl ame is engulfi ng the sensor rod. This will increase the fl ame rectifi cation. Verify correct pilot orifi ce is installed and inlet gas specifi cations to manual. (Remember, the fl ame carries the rectifi cation current, not the gas. If the fl ame lifts from pilot hood, the circuit is broken. A wrong orifi ce or to high of an inlet pressure can cause the pilot fl ame to lift.) The sensor rod may need cleaning.
Verify that the wire harness is fi rmly connected to module.
Verify that the ceramic insulator around the sensor rod is not cracked, damaged, or loose. Verify the connection from the sensor rod to the sensor wire.
Clean sensor rod with a fi ne emery cloth or synthetic scrub pad to remove any contamination that may have accumulated on the sensor rod. Verify continuity with multimeter with ohms set at the lowest range.
Inspect all wires, ensure good tight connections. Verify that all wiring is installed exactly as specifi ed.
Inspect the wiring harness, and verify the harness is tightly connected to the module. Verify that all wires are connected in the right order. See “WIRING DIAGRAM” section.
Check all seals.
Check if exhaust is re-entering through an open door or window.
-
Clean the glass, see “CARE OF GLASS” section
DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may become permanently marked.
Tighten door clamps if applicable.
Restrict vent exit with restrictor plate. See
“RESTRICTING VENTS” section if applicable.
Remove blockage. In extreme conditions, ice buildup may occur on the terminal and should be removed. To minimize this from happening again, it is recommended that the vent lengths that pass through unheated spaces (attics, garages, crawl spaces) be wrapped with an insulated mylar sleeve. Prevent sleeve from sagging. Contact your local authorized dealer for more information.
Check venting system parameters (seal, length, rise, etc.).
Check joint seals and installation.
42.7_2A
EN
W415-1606 / 09.09.16
48
EN
14.0 WARRANTY
NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality
Assurance Certifi cate.
NAPOLEON products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete appliance is again thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
NAPOLEON GAS APPLIANCE PRESIDENT’S LIFETIME LIMITED WARRANTY
The following materials and workmanship in your new NAPOLEON gas appliance are warranted against defects for as long as you own the appliance. This covers: combustion chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, rocks, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enameled components and aluminum extrusion trims.*
Electrical (110V and millivolt) components and wearable parts are covered and NAPOLEON will provide replacement parts free of charge during the fi rst year of the limited warranty. This covers: blowers, gas valves, thermal switches, switches, wiring, remote controls, ignitors, gaskets and pilot assemblies.*
Labour related to warranty repair is covered free of charge during the fi rst year. Repair work, however, requires the prior approval of an authorized company offi cial. Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer.
* Construction of models vary. Warranty applies only to components included with your specifi c appliance.
CONDITIONS AND LIMITATIONS
NAPOLEON warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not necessary. Simply provide your proof of purchase along with the model and serial number to make a warranty claim. NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim. Provided that the purchase was made through an authorized NAPOLEON dealer your appliance is subject to the following conditions and limitations:
Warranty coverage begins on the date of original installation.
This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives.
The gas appliance must be installed by a licensed, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building and fi re codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers.
This warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.
After the fi rst year, with respect to this President’s Lifetime Limited Warranty, NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
NAPOLEON will not be responsible for installation, labour or any other expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty.
Notwithstanding any provisions contained in the President’s Lifetime Limited Warranty, NAPOLEON’S responsibility under this warranty is defi ned as above and it shall not in any event extend to any incidental, consequential or indirect damages.
This warranty defi nes the obligations and liability of NAPOLEON with respect to the NAPOLEON gas appliance and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product.
NAPOLEON will not be responsible for: over-fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to the appliance, combustion chamber, heat exchanger, plated trim or other components due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.
All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim.
During the fi rst 10 years NAPOLEON will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON will provide replacement parts at 50% of the current retail price.
All parts replaced under the warranty will be covered for a period of 90 days from the date of their installation.
The manufacturer may require that defective parts or products be returned or that digital pictures be provided to support the claim. Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the manufacturer will repair or replace such defect.
Before shipping your appliance or defective components, your dealer must obtain an authorization number. Any merchandise shipped without authorization will be refused and returned to sender.
Shipping costs are not covered under this warranty.
Additional service fees may apply if you are seeking warranty service from a dealer.
Warranty labour allowance is only for the replacement of the warranted part. Travel, diagnostic tests, shipping and other related charges are not covered by this warranty.
ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT
IMPROVEMENTS. NAPOLEON IS A REGISTERED TRADEMARK OF WOLF STEEL LTD.
W415-1606 / 09.09.16
2.1D
15.0 SERVICE HISTORY
49
EN
43.1
W415-1606 / 09.09.16
EN
50
16.0 NOTES
W415-1606 / 09.09.16
44.1
44.1
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8
214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8
103 Miller Drive, Crittenden, Kentucky, USA 41030
7200 Trans Canada Highway, Montreal, Quebec, Canada H4T 1A3
Fireplaces / Heating & Cooling call: 705-721-1212 • Grills call: 705-726-4278 napoleonproducts.com
Fireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves
Heating & Cooling • Electric Fireplaces • Outdoor Fireplaces • Gas Grills