advertisement
▼
Scroll to page 2
of 75
Convertible Console YOHC 12 to 60 SERVICE MANUAL YOHC 12 · YOHC 18 · YOHC 24 YOHC 36 · YOHC 48 · YOHC 60 SM-YOHC-12-60GB 03-07 Contents Part 1 General information…………………………………………………. Part 2 Indoor units…………………………………………………………… Part 3 Outdoor units……………………………………………………….. Part 4 Installation…………………...……………………………………… Part 5 Control……………………………………………………………….. Part 1 General Information 1. Model names of Indoor/Outdoor Units…………………………………… 2. External Appearance………………………………………………………... 3. Nomenclature………………………………………………………………… 4. Features……………………………………………………………………….. Model Names of Indoor/ Outdoor Units Model Names of Indoor Units: YOKC-12 YOKC-18 YOKC-24 YOKC-30 YOKC-36 YOKC- 48 YOKC-60 Model Names of Outdoor Units: YOJC-12 YOJC-18 YOJC-24 YOJC-30 YOJC-36 YOJC-48 YOJC-60 1. External Appearance 1.1 Indoor units 1.2 Outdoor units 2. Nomenclature How to read the model? Y O H C 24 F S B* A* * A R Range: F = Floor standing H = High wall M = Master range P = Portable Y = YORK R = Everest front Generation: A = First R = New remote Voltages: A = (Out) 220-240/1/50 - (In) 220-240/1/50 C = (Out) 380/3/50 - (In) 220-240/1/50 Family: A = Efficiency Ultra E = Eco Ultra H = Alps J = Atlas K = Cassette L = Ultra M = Multi Ultra R = Multi Inverter V = Inverter Ultra U = Ducted unit O = Floor / Ceiling Type: C = Set - Cooling only D = Outdoor - Cooling only E = Indoor - Cooling only H = Set - Heat pump J = Outdoor Heat pump K = Indoor Heat pump M = Multi Ultra R = Multi Inverter V = Inverter Ultra U = Ducted unit O = Floor / Ceiling Refrigerant type: A = R22 B = R407C C = R410A Indoor options: A = Standard J = Bio Screen filter ** Omit for outdoor units Outdoor options: A = Standard B = Low Ambient Kit C = Power outdoor * Omit for indoor units Indoors: A = Free matching multi S = Single T = Duct High Static U = Duct standard case Compressor type: A = AC Inverter D = DC Inverter F = Fixed M = Multi Capacity Btu/h 3. Features 4.1. New design, more modern and elegant appearance; 4.2. Convenient installation; 4.3. Two direction auto swing (vertical & horizontal) and wide angle air flow; 4.4. Three level fan speed, more humanism design, meets different air-supply requirement; 4.5. Water proof by utilizing the absorbing plastic film on water collector; 4.6. Easy operation. Auto-restart function, remote control and optional wire control method; 4.7. Low noise level plus compact size; 4.8. Universal outdoor design. Part 2 Indoor units Ceiling & Floor Type………………………………………………………… Ceiling & Floor Type 1. Features…………………………………………………………………………………………….. 2. Specification……………………………………………………………………………………….. 3. Dimensions……………………………………………………………………………………….. 4. Service space…………………………………………………………………………………….. 5. Piping diagrams………………………………………………………………………………….. 6. Wiring diagrams………………………………………………………………………………….. 7. Capacity Tables…………………………………………………………………………………... 8. Air Velocity and Temperature Distributions…………………………………………………. 9. Electric Characteristics…………………………………………………………………………. 10. Sound Levels……………………………………………………………………………………... 11. Exploded view……………………………………………………………………………………. 1. Features 1.1. New design, more modern and elegant appearance. 1.2. Convenient installation --The ceiling type can be easily installed into a corner of the ceiling even if the ceiling is very narrow --It is especially useful when installation of an air conditioner in the center of the ceiling is impossible due to a structure such as one lighting 1.3. Two direction auto swing (vertical & horizontal) and wide angle air flow --Air flow directional control minimizes the air resistance and produces wilder air flow to vertical direction. --The range of horizontal air discharge is widened which secures wider air flow distribution to provide more comfortable air circulation no matter where the unit is set up 1.4. Three level fan speed, more humanism design, meets different air-supply requirement. 1.5. Water proof by utilizing the absorbing plastic film on water collector 1.6. Easy operation. Auto-restart function, remote control and optional wire control method. 1.7. Low noise level plus compact size --Shape of the blades has been improved to prevent noise caused by turbulence. 2. Specification Model Power supply Cooling Ph-V-Hz YOHC -12 YOHC -18 YOHC -24 1,220-240V,50Hz 1,220-240V,50Hz 1,220-240V,50Hz 12000 18000 24000 Capacity Btu/h Capacity kW 3.5 5.4 7.1 Input W 1200 1900 2700 Rated current A 6.0 8.5 12.0 Btu/W.h 10.0 9.7 8.9 13500 20000 26000 EER Capacity Btu/h Capacity kW 4 5.9 7.7 Input W 1130 1850 2800 Rated current A 5.0 8.0 12.5 Btu/W.h 12.0 10.9 9.3 L/h 1.2 1.8 2.4 Max. input consumption W 1500 2400 3300 Max. current A 7.0 11.5 14.5 Starting current A 26 36.8 61 PA140X2C-4FT PA225X2CS-4KU PA290X3CS-4MU1 ROTARY ROTARY ROTARY Brand MIDEA-TOSHIBA MIDEA-TOSHIBA MIDEA- TOSHIBA Supplier MIDEA-TOSHIBA MIDEA-TOSHIBA MIDEA-TOSHIBA Btu/h 11567 18834 24498 W 1145 1870 2430 Rated current(RLA) A 5.3 8.75 11.4 Locked rotor Amp(LRA) A 26 36.8 61 INNER INNER INNER 35/370 µF/V 50/370 µF/V 50/400 µF/V Heating COP Moisture Removal Model Type Capacity Compressor Input Thermal protector Capacitor uF Refrigerant oil ml RB68AF/T68/Α68tf Model 480 ESTER OIL VG74 750 ESTER OIL CG74 950 YSK25-6L YSK55-4L YSK55-4L Indoor fan Input W 33.4/31.1/29.5 115/95/78 115/95/78 motor Capacitor uF 1.2uF/450V 2.5uF/450V 2.5uF/450V r/min 756/666/592 1310/ 1190/1040 1310/ 1190/1040 2 3 3 Speed(hi/lo) Number of rows Indoor coil Tube pitch(a)x row pitch(b) mm 25.4×22 25.4×22 25.4×22 Fin spacing mm 1.8 1.8 1.8 Hydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum Fin type Tube outside dia. and type mm Ф9.53 innergroove tube Ф9.53 innergroove tube Ф9.53 innergroove tube Coil length x height x width mm 804×254×44 804×254×66 804×254×66 3 m /h 600/480/400 800/600/500 1200/900/700 dB(A) 43/41/38 43/41/38 45/43/40 Indoor air flow(Hi/Mid/Lo) Indoor noise level (Hi/Mid/Lo) Dimension (W*H*D)(body) Indoor unit Packing (W*H*D)(body) Net/Gross weight(body) mm 995×660×198 995×660×198 995×660×198 mm 1089×744×296 1089×744×296 1089×744×296 27/33 27/33 27/33 YDK24-6F YDK53-6K YDK53-6H W 56 130 138 uF 2.5uF/450V 3uF/450V 3µF/450V 800 750 800 2 2 2 kg Model Outdoor fan Input motor Capacitor Speed r/min Number of rows Tube pitch(a)x row pitch(b) mm 21x13.37 25.4×22 25.4×22 Fin spacing mm 1.5 1.7 1.5 Unhydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum Outdoor coil Fin type Tube outside dia. and type mm Φ7,Innergroove tube Ф9.53,Innergroove tube Ф9.53,innergroove tube Coil length x height x width mm 651x559x26.7 775×660×44 850×810×44 2 3 4 m /h 2100 2400 3000 dB(A) 43 48 55 Number of circuits Outdoor air flow Outdoor noise level Outdoor unit Dimension(W*H*D) mm 760×590×285 845×695×335 895×860×330 Packing (W*H*D) mm 887x655x355 970X770X395 1043X915X395 Net/ Gross weight kg 44/48 52/56 68/70 g R410A/1120 R410A/2050 R410A/2600 4.2/2.5 4.2/2.5 4.2/2.5 mm(inch) 6.35 (1/4) 6.35 (1/4) 9.53 (3/8) mm(inch) 12.7 (1/2) 12.7 (1/2) 16 (5/8) Refrigerant type/Quantity Design pressure (high side/low side) Liquid side Refrigerant Gas side piping 3 MPa Max. pipe length m 25 25 30 Max. difference in level m 15 15 15 Operation temp ºC 17~30 17~30 17~30 Ambient temp ºC -7~45 -7~45 -7~45 2 18~26 34~49 40~56 63/138/155 49/104/126 44/94/101 Application area Qty’per 20’& 40’Fcl m Pieces Model Power supply Cooling Ph-V-Hz YOHC -30 YOHC -30 YOHC -36 3,380V,50Hz 1,220-240V,50Hz 1,220-240V,50Hz 30000 30000 36,000 Capacity Btu/h Capacity kW 9.2 9.2 10.5 Input W 3750 3750 3750 Rated current A 6.3 16.3 16.3 Btu/W.h 8.0 8.0 9.6 32000 32000 39000 EER Capacity Btu/h Capacity kW 9.4 9.4 11.4 Input W 3500 3500 3500 Rated current A 5.2 15.2 15.2 Btu/W.h 9.2 9.2 11.2 L/h 3 3 3.6 Max. input consumption W 4620 4620 4620 Max. current A 7.1 21 21 Starting current A 61 97 97 C-SBN303H8D C-SBN301H5D C-SBN301H5D Type SCROLL SCROLL SCROLL Brand SANYO SANYO SANYO SANYO(Dalian) SANYO SANYO Btu/h 33438 33438 33438 Input W 3650 3650 3650 Rated current(RLA) A 6.58 17.65 17.65 Locked rotor Amp(LRA) A 61 97 97 INNER INNER INNER / 60uF/440V 60uF/440V FV68S 1700 FV68S 1700 YSK80-4A YSK80-4A YSK80-4A Heating COP Moisture Removal Model Supplier Capacity Compressor Thermal protector Capacitor uF Refrigerant oil ml DAPHNE FV68S 1700 Model Indoor fan Input W 142/134/132 142/134/132 142/134/132 motor Capacitor uF 3.5uF/450V 3.5uF/450V 3.5uF/450V 1310/1200/1000 1310/1200/1000 1310/1200/1000 3 3 3 Speed(hi/lo) r/min Number of rows Indoor coil Tubepitch(a)x row pitch(b) mm 25.4×22 25.4×22 25.4×22 Fin spacing mm 1.7 1.7 1.7 Hydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum Fin type Tube outside dia.and type mm Ф9.53, inner groove tube Ф9.53, inner groove tube Ф9.53, inner groove tube Coil length x height x width mm 905×203×66 905×203×66 905×203×66 3 m /h 1200/1000/800 1400/1200/1000 1400/1200/1000 dB(A) 45/43/40 45/43/40 45/43/40 Indoor air flow(Hi/Mid/Lo) Indoor noise level (Hi/Mid/Lo) Indoor unit Dimension (W*H*D)(body) mm 1285×660×198 1285×660×198 1285×660×198 Packing mm 1365×744×278 1365×744×278 1365×744×278 34/42 34/42 34/42 YDK250-6D YDK250-6D YDK250-6D (W*H*D)(body) Net/Gross weight(body) kg Model Outdoor fan motor Input W 307 307 307 Capacitor uF 10µF/450V 10 uF/450V 10 uF/450V 740 740 740 2 2 2 Speed r/min Number of rows Outdoor coil Tube pitch(a)x row pitch(b) mm 25.4×22 25.4×22 25.4×22 Fin spacing mm 1.7 1.7 1.7 Unhydrophilic aluminium unhydrophilic aluminium Fin type Tube outside dia.and type mm Ф9.53,innergroove tube Coil length x height x width mm Outdoor noise level Outdoor unit Ф9.53, inner groove tube Ф9.53, inner groove tube 955×915×44 955×915×44 955×915×44 8 8 8 m /h 5000 5000 5000 dB(A) 57 57 57 Number of circuits Outdoor air flow unhydrophilic aluminium 3 Dimension(W*H*D) mm 990×960×360 990×960×360 990×960×360 Packing (W*H*D) mm 1120X1090X435 1120X1090X435 1120X1090X435 Net/ Gross weight kg 90/102 90/102 90/102 g R410A/3100 R410A 3450 R410A 3450 4.2/2.5 4.2/2.5 4.2/2.5 Refrigerant type/Quantity Design pressure (high side/low side) MPa Liquid side mm(inch) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) Refrigerant Gas side mm(inch) 19 (3/4) 19 (3/4) 19 (3/4) piping Max. pipe length m 30 30 30 Max. difference in level m 20 20 20 Operation temp ºC 17~30 17~30 17~30 Ambient temp ºC -7~45 -7~45 -7~45 2 50~75 60~85 60~85 27/55/62 27/55/62 27/55/62 Application area Qty’per 20’& 40’Fcl m Pieces Model Power supply Cooling Ph-V-Hz YOHC -36 YOHC -48 YOHC -60 3,380V,50Hz 3,380V,50Hz 3,380V,50Hz 36000 48000 60,000 Capacity Btu/h Capacity kW 10.5 14 17 Input W 3750 4700 6000 Rated current A 6.6 8.2 9.8 Btu/W.h 9.6 10.2 10.0 39000 52000 68,000 EER Capacity Btu/h Capacity kW 11.4 15.2 20 Input W 3700 4900 6000 Rated current A 6.5 8.6 9.8 Btu/W.h 10.6 10.6 11.4 L/h 3.8 4.8 6 Max. input consumption W 4400 5870 7500 Max. current A 8.0 10.7 12.8 Starting current A 61 66 67 C-SBN303H8D C-SBN373H8D C-SBN453H8D Type SCROLL SCROLL SCROLL Brand SANYO SANYO SANYO SANYO(Dalian) SANYO(Dalian) SANYO(Dalian) Btu/h 33438 48109 55957 Input W 3650 4750 5750 Rated current(RLA) A 6.58 8.22 9.77 Locked rotor Amp(LRA) A 61 66 67 INNER INNER INNER Heating COP Moisture Removal Model Supplier Capacity Compressor Thermal protector Capacitor uF / / / Refrigerant oil ml DAPHNE FV68S 1700 DAPHNE FV68S 1700 DAPHNE FV68S 1700 YSK80-4A YSK59-4A YSK59-4A Model Indoor fan Input W 142/134/132 118/108/101 118/108/101 motor Capacitor uF 3.5uF/450V 2.5uF/450V 2.5uF/450V 1310/1200/1000 820/695/620 820/695/620 3 3 3 Speed(hi/lo) r/min Number of rows Indoor coil Tube pitch(a)x row pitch(b) mm 25.4×22 25.4X22 25.4X22 Fin spacing mm 1.7 1.7 1.7 Hydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum Ф9.53, inner groove tube Ф9.53, inner groove tube mm 905×203×66 1150x254x66 1150x254x66 3 m /h 1400/1200/1000 2000/1800/1600 2000/1800/1600 dB(A) 45/43/40 47/45/42 47/45/42 Fin type Tube outside dia. and type Coil length x height x width Indoor air flow(Hi/Mid/Lo) Indoor noise level (Hi/Mid/Lo) mm Ф9.53, inner groove tube Indoor unit Dimension (W*H*D)(body) mm 1285×660×198 1670×680×240 1670×680×240 Packing mm 1365×744×278 1764×760×329 1764×760×329 34/42 52/62 52/62 YDK250-6D YDK65-6; YDK65-6F YDK65-6F; YDK65-6F (W*H*D)(body) Net/Gross weight(body) kg Model Outdoor fan motor Input W 307 138+156 138+156 Capacitor uF 10 uF/450V 3.5×2 uF/450V 3.5×2 uF/450V 740 800 800 2 2 2 Speed r/min Number of rows Outdoor coil Tube pitch(a)x row pitch(b) mm 25.4×22 25.4×22 25.4×22 Fin spacing mm 1.7 1.8 1.8 Fin type unhydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum Tube outside dia. and type Ф9.53, inner groove tube Ф9.53, inner groove tube 955×915×44 715×1220×44 715×1220×44 8 4 4 m /h 5000 6000 6000 dB(A) 57 58 58 Coil length x height x width mm mm Number of circuits 3 Outdoor air flow Outdoor noise level Outdoor unit Ф9.53, inner groove tube Dimension(W*H*D) mm 990×960×360 940×1245×340 940×1245×340 Packing (W*H*D) mm 1120X1090X435 1058X1380X435 1058X1380X435 Net/ Gross weight kg 90/102 112/127 112/127 g R410A/3100 R410A/4000 R410A/4200 4.2/2.5 4.2/2.5 4.2/2.5 Refrigerant type/Quantity Design pressure (high side/low side) MPa Liquid side mm(inch) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) Refrigerant Gas side mm(inch) 19 (3/4) 19 (3/4) 19 (3/4) piping Max. pipe length m 30 50 50 Max. difference in level m 20 30 30 17~30 17~30 17~30 -7~45 -7~45 -7~45 60~85 80~105 95~120 27/55/62 25/50/54 25/50/54 Operation temp Ambient temp Application area Qty’per 20’& 40’Fcl 2 m Pieces Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. 3. Dimensions 3.1. YOKC-12 YOKC-18 YOKC-24 995 980 Strengthener 402 4-12¡ Á 18 Overhanging hole Drain point Connecting point of refrigerant pipe Connecting point of refrigerant pipe (Liquid side) (gas side) 3.2. YOKC-30 YOKC-36 1285 980 Strengthener 402 4-12¡ Á 18 Overhanging hole Drain point Connecting point of refrigerant pipe Connecting point of refrigerant pipe (Liquid side) (gas side) 3.3. YOKC-48 YOKC-60 1670 980 Strengthener 402 4-12¡ Á 18 Overhanging hole Drain point Connecting point of refrigerant pipe Connecting point of refrigerant pipe (gas side) (Liquid side) 4. Service space >600mm >600mm 5. Piping Diagrams Remark: 1. For YOJC-12 and YOJC-18, accumulator is not included. 2. For YOJC-30, YOJC-36 and YOJC-48, check valve and auxiliary capillary is not included. 6. Wiring Diagrams 6.1 Cooling & Heating 6.1.1 YOKC-12 DI SPLAY BOARD XP1 XS1 I NDOOR W I RI NG DI AGRAM CN12 (W HI TE) CN10 CN13 ( RED) CODE CN15 CAP1 RL8 CN1- CN24 P. C. BOARD SOCKETS T4 TRANSFORMER FAN1 I NDOOR FAN CONNECTORS XP1~4 MAI N CONTROL BOARD CN3 CN5 CN1 CN2 PART NAM E I NDOOR FAN CAP CN16 XS1~4 T4 XP3 XS3 Y/ G RT2 PI PE TEMP. SENSOR 5- W AY TERMI NAL 6- W AY TERMI NAL RELAY FOR COMPRESSOR LEVEL SW I NG MOTOR PLUMB SW I NG MOTOR KM1 GM 1 W HI TE W HI TE ROOM TEMP. SENSOR XT1 XT2 FAN1 CONNECTORS RT1 GM2 BLUE( N) RED BLACK BLACK( C) RED W HI TE BLACK BLACK( L) BLUE( S. V) XT1 L 3 4 5 W HI TE( T3) XT2 N 1 2(N) BLACK( E) KM1 BLACK( HI ) RED( LO) CAP1 Y/ G Y/ G TO OUTDOOR UNI T POW ER TO OUTDOOR UNI T 6.1.2. YOKC -18 DI SPLAY BOARD XP1 XS1 I NDOOR W I RI NG DI AGRAM CN12 (W HI TE) CN10 CN13 ( RED) CODE CN15 CAP1 RL8 CN1- CN24 P. C. BOARD SOCKETS T4 TRANSFORMER FAN1 I NDOOR FAN CONNECTORS XP1~4 MAI N CONTROL BOARD CN3 CN5 CN1 CN2 CN16 XS1~4 T4 XP3 XS3 Y/ G W HI TE ROOM TEMP. SENSOR RT2 PI PE TEMP. SENSOR 5- W AY TERMI NAL KM1 GM 1 W HI TE GM2 BLUE( N) RED BLACK( C) BLACK RED W HI TE BLACK BLACK( L) BLACK( HI ) RED( LO) BLUE( S. V) CAP1 XT1 L BLACK( E) 3 4 5 W HI TE( T3) XT2 TO OUTDOOR UNI T N 1 2(N) Y/ G Y/ G TO OUTDOOR UNI T POW ER CONNECTORS RT1 XT1 XT2 FAN1 KM1 PART NAM E I NDOOR FAN CAP 6- W AY TERMI NAL RELAY FOR COMPRESSOR LEVEL SW I NG MOTOR PLUMB SW I NG MOTOR 6.1.3. YOKC -24 6.1.4. YOKC -30 6.1.5. YOKC -36 6.1.6. YOKC -48 YOKC -60 7. Capacity Tables Model: YOHC-12 Cooling OUTDOOR TEMPERATURE DRY Indoor 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC Total capacity kW 3.38 3.23 3.12 2.94 2.82 2.73 2.65 Sensitive capacity kW 2.70 2.59 2.49 2.35 2.26 2.19 2.12 Input kW. 0.76 0.86 0.97 1.08 1.19 1.30 1.40 Total capacity kW 3.70 3.54 3.41 3.22 3.09 2.99 2.90 Sensitive capacity kW 2.96 2.83 2.73 2.58 2.47 2.40 2.32 Input kW. 0.80 0.91 1.03 1.14 1.25 1.37 1.48 Total capacity kW 4.03 3.85 3.71 3.50 3.36 3.26 3.15 Sensitive capacity kW 3.22 3.08 2.97 2.80 2.69 2.60 2.52 Input kW. 0.84 0.96 1.08 1.20 1.32 1.44 1.56 Total capacity kW 4.63 4.43 4.27 4.03 3.86 3.74 3.62 Sensitive capacity kW 3.70 3.54 3.41 3.22 3.09 2.99 2.90 Input kW. 0.97 1.10 1.24 1.38 1.52 1.66 1.79 Conditions 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Heating OUTDOOR CONDITIONS Indoor 24ºC D 12ºC D 7ºC D 4ºC D 0ºC D -5ºC D -7ºC D -15ºC D Conditions 18ºC W 11ºC W 6ºC W 3ºC W -1ºC W -6ºC W -8ºC W -16ºC W Capacity kW 6.56 5.24 4.37 3.93 3.71 3.28 3.06 2.84 Input kW. 1.95 1.56 1.30 1.23 1.17 1.10 1.04 0.91 Capacity kW 6.16 4.92 4.10 3.69 3.49 3.08 2.87 2.67 Input kW. 1.83 1.46 1.22 1.16 1.10 1.04 0.98 0.85 Capacity kW 5.70 4.56 3.80 3.42 3.23 2.85 2.66 2.47 Input kW. 1.70 1.36 1.13 1.07 1.02 0.96 0.90 0.79 Capacity kW 5.24 4.20 3.50 3.15 2.97 2.62 2.45 2.27 Input kW. 1.56 1.25 1.04 0.99 0.94 0.88 0.83 0.73 Capacity kW 4.56 3.65 3.04 2.74 2.58 2.28 2.13 1.98 Input kW. 1.36 1.08 0.90 0.86 0.81 0.77 0.72 0.63 15ºC 18ºC 20ºC 22ºC 27ºC Model: YOHC -18 Cooling OUTDOOR TEMPERATURE DRY Indoor 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC Total capacity kW 5.22 4.99 4.81 4.54 4.35 4.22 4.08 Sensitive capacity kW 4.17 3.99 3.85 3.63 3.48 3.37 3.27 Input kW. 1.20 1.37 1.54 1.71 1.88 2.05 2.22 Total capacity kW 5.71 5.46 5.27 4.97 4.77 4.62 4.47 Sensitive capacity kW 4.57 4.37 4.21 3.97 3.82 3.70 3.58 Input kW. 1.26 1.44 1.62 1.81 1.99 2.17 2.35 Total capacity kW 6.21 5.94 5.72 5.40 5.18 5.02 4.86 Sensitive capacity kW 4.97 4.75 4.58 4.32 4.15 4.02 3.89 Input kW. 1.33 1.52 1.71 1.90 2.09 2.28 2.47 Total capacity kW 7.14 6.83 6.58 6.21 5.96 5.78 5.59 Sensitive capacity kW 5.71 5.46 5.27 4.97 4.77 4.62 4.47 Input kW. 1.53 1.75 1.97 2.19 2.40 2.62 2.84 Conditions 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Heating OUTDOOR CONDITIONS Indoor 24ºC D 12ºC D 7ºC D 4ºC D 0ºC D -5ºC D -7ºC D -15ºC D Conditions 18ºC W 11ºC W 6ºC W 3ºC W -1ºC W -6ºC W -8ºC W -16ºC W Capacity kW 10.35 8.28 6.90 6.21 5.87 5.18 4.83 4.49 Input kW. 3.19 2.55 2.13 2.02 1.91 1.81 1.70 1.49 Capacity kW 9.72 7.78 6.48 5.83 5.51 4.86 4.54 4.21 Input kW. 3.00 2.40 2.00 1.90 1.80 1.70 1.60 1.40 Capacity kW 9.00 7.20 6.00 5.40 5.10 4.50 4.20 3.90 Input kW. 2.78 2.22 1.85 1.76 1.67 1.57 1.48 1.30 Capacity kW 8.28 6.62 5.52 4.97 4.69 4.14 3.86 3.59 Input kW. 2.55 2.04 1.70 1.62 1.53 1.45 1.36 1.19 Capacity kW 7.20 5.76 4.80 4.32 4.08 3.60 3.36 3.12 Input kW. 2.22 1.78 1.48 1.41 1.33 1.26 1.18 1.04 15ºC 18ºC 20ºC 22ºC 27ºC Model: YOHC -24 Cooling OUTDOOR TEMPERATURE DRY Indoor 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC Total capacity kW 6.86 6.56 6.32 5.96 5.73 5.55 5.37 Sensitive capacity kW 5.49 5.25 5.06 4.77 4.58 4.44 4.29 Input kW. 1.70 1.94 2.19 2.43 2.67 2.92 3.16 Total capacity kW 7.51 7.19 6.92 6.53 6.27 6.07 5.88 Sensitive capacity kW 6.01 5.75 5.54 5.23 5.02 4.86 4.70 Input kW. 1.80 2.05 2.31 2.57 2.82 3.08 3.33 Total capacity kW 8.17 7.81 7.53 7.10 6.82 6.60 6.39 Sensitive capacity kW 6.53 6.25 6.02 5.68 5.45 5.28 5.11 Input kW. 1.89 2.16 2.43 2.70 2.97 3.24 3.51 Total capacity kW 9.39 8.98 8.65 8.17 7.84 7.59 7.35 Sensitive capacity kW 7.51 7.19 6.92 6.53 6.27 6.07 5.88 Input kW. 2.17 2.48 2.79 3.11 3.42 3.73 4.04 Conditions 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Heating OUTDOOR CONDITIONS Indoor 24ºC D 12ºC D 7ºC D 4ºC D 0ºC D -5ºC D -7ºC D -15ºC D Conditions 18ºC W 11ºC W 6ºC W 3ºC W -1ºC W -6ºC W -8ºC W -16ºC W Capacity kW 13.80 11.04 9.20 8.28 7.82 6.90 6.44 5.98 Input kW. 4.83 3.86 3.22 3.06 2.90 2.74 2.58 2.25 Capacity kW 12.96 10.37 8.64 7.78 7.34 6.48 6.05 5.62 Input kW. 4.54 3.63 3.02 2.87 2.72 2.57 2.42 2.12 Capacity kW 12.00 9.60 8.00 7.20 6.80 6.00 5.60 5.20 Input kW. 4.20 3.36 2.80 2.66 2.52 2.38 2.24 1.96 Capacity kW 11.04 8.83 7.36 6.62 6.26 5.52 5.15 4.78 Input kW. 3.86 3.09 2.58 2.45 2.32 2.19 2.06 1.80 Capacity kW 9.60 7.68 6.40 5.76 5.44 4.80 4.48 4.16 Input kW. 3.36 2.69 2.24 2.13 2.02 1.90 1.79 1.57 15ºC 18ºC 20ºC 22ºC 27ºC Model: YOHC -30 Cooling OUTDOOR TEMPERATURE DRY Indoor 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC Total capacity kW 8.89 8.50 8.19 7.73 7.42 7.19 6.96 Sensitive capacity kW 7.11 6.80 6.55 6.18 5.94 5.75 5.56 Input kW. 2.36 2.70 3.04 3.38 3.71 4.05 4.39 Total capacity kW 9.73 9.31 8.97 8.46 8.13 7.87 7.62 Sensitive capacity kW 7.79 7.45 7.18 6.77 6.50 6.30 6.09 Input kW. 2.49 2.85 3.21 3.56 3.92 4.28 4.63 Total capacity kW 10.58 10.12 9.75 9.20 8.83 8.56 8.28 Sensitive capacity kW 8.46 8.10 7.80 7.36 7.07 6.84 6.62 Input kW. 2.63 3.00 3.38 3.75 4.13 4.50 4.88 Total capacity kW 12.17 11.64 11.21 10.58 10.16 9.84 9.52 Sensitive capacity kW 9.73 9.31 8.97 8.46 8.13 7.87 7.62 Input kW. 3.02 3.45 3.88 4.31 4.74 5.18 5.61 Conditions 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Indoor 24ºC D 12ºC D 7ºC D 4ºC D 0ºC D -5ºC D -7ºC D -15ºC D Conditions 18ºC W 11ºC W 6ºC W 3ºC W -1ºC W -6ºC W -8ºC W -16ºC W Capacity kW 16.22 12.97 10.81 9.73 9.19 8.11 7.57 7.03 Input kW. 6.04 4.83 4.03 3.82 3.62 3.42 3.22 2.82 Capacity kW 15.23 12.18 10.15 9.14 8.63 7.61 7.11 6.60 Input kW. 5.67 4.54 3.78 3.59 3.40 3.21 3.02 2.65 Capacity kW 14.10 11.28 9.40 8.46 7.99 7.05 6.58 6.11 Input kW. 5.25 4.20 3.50 3.33 3.15 2.98 2.80 2.45 Capacity kW 12.97 10.38 8.65 7.78 7.35 6.49 6.05 5.62 Input kW. 4.83 3.86 3.22 3.06 2.90 2.74 2.58 2.25 Capacity kW 11.28 9.02 7.52 6.77 6.39 5.64 5.26 4.89 Input kW. 4.20 3.36 2.80 2.66 2.52 2.38 2.24 1.96 15ºC 18ºC 20ºC 22ºC 27ºC Model: YOHC -36 Cooling OUTDOOR TEMPERATURE DRY Indoor 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 10.14 9.70 9.35 8.82 8.47 8.20 7.94 Sensitive capacity kW 8.11 7.76 7.48 7.06 6.77 6.56 6.35 Input kW. 2.36 2.70 3.04 3.38 3.71 4.05 4.39 Total capacity kW 11.11 10.63 10.24 9.66 9.27 8.98 8.69 Sensitive capacity kW 8.89 8.50 8.19 7.73 7.42 7.19 6.96 Input kW. 2.49 2.85 3.21 3.56 3.92 4.28 4.63 Total capacity kW 12.08 11.55 11.13 10.50 10.08 9.77 9.45 Sensitive capacity kW 9.66 9.24 8.90 8.40 8.06 7.81 7.56 Input kW. 2.63 3.00 3.38 3.75 4.13 4.50 4.88 Total capacity kW 13.89 13.28 12.80 12.08 11.59 11.23 10.87 Sensitive capacity kW 11.11 10.63 10.24 9.66 9.27 8.98 8.69 Input kW. 3.02 3.45 3.88 4.31 4.74 5.18 5.61 Conditions Total capacity kW 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Heating OUTDOOR CONDITIONS Indoor 24ºC D 12ºC D 7ºC D 4ºC D 0ºC D -5ºC D -7ºC D -15ºC D Conditions 18ºC W 11ºC W 6ºC W 3ºC W -1ºC W -6ºC W -8ºC W -16ºC W Capacity kW 19.67 15.73 13.11 11.80 11.14 9.83 9.18 8.52 Input kW. 6.38 5.11 4.26 4.04 3.83 3.62 3.40 2.98 Capacity kW 18.47 14.77 12.31 11.08 10.47 9.23 8.62 8.00 Input kW. 5.99 4.80 4.00 3.80 3.60 3.40 3.20 2.80 Capacity kW 17.10 13.68 11.40 10.26 9.69 8.55 7.98 7.41 Input kW. 5.55 4.44 3.70 3.52 3.33 3.15 2.96 2.59 Capacity kW 15.73 12.59 10.49 9.44 8.91 7.87 7.34 6.82 5.11 4.08 3.40 3.23 3.06 2.89 2.72 2.38 Capacity kW 13.68 10.94 9.12 8.21 7.75 6.84 6.38 5.93 Input kW. 4.44 3.55 2.96 2.81 2.66 2.52 2.37 2.07 15ºC 18ºC 20ºC 22ºC 27ºC Input kW. Model: YOHC -48 Cooling OUTDOOR TEMPERATURE DRY Indoor 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC Total capacity kW 13.52 12.94 12.47 11.76 11.29 10.94 10.58 Sensitive capacity kW 10.82 10.35 9.97 9.41 9.03 8.75 8.47 Input kW. 2.96 3.38 3.81 4.23 4.65 5.08 5.50 Total capacity kW 14.81 14.17 13.65 12.88 12.36 11.98 11.59 Sensitive capacity kW 11.85 11.33 10.92 10.30 9.89 9.58 9.27 Input kW. 3.13 3.57 4.02 4.47 4.91 5.36 5.80 Total capacity kW 16.10 15.40 14.84 14.00 13.44 13.02 12.60 Sensitive capacity kW 12.88 12.32 11.87 11.20 10.75 10.42 10.08 Input kW. 3.29 3.76 4.23 4.70 5.17 5.64 6.11 Total capacity kW 18.52 17.71 17.07 16.10 15.46 14.97 14.49 Sensitive capacity kW 14.81 14.17 13.65 12.88 12.36 11.98 11.59 Input kW. 3.78 4.32 4.86 5.41 5.95 6.49 7.03 Conditions 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Heating OUTDOOR CONDITIONS Indoor 24ºC D 12ºC D 7ºC D 4ºC D 0ºC D -5ºC D -7ºC D -15ºC D Conditions 18ºC W 11ºC W 6ºC W 3ºC W -1ºC W -6ºC W -8ºC W -16ºC W Capacity kW 26.22 20.98 17.48 15.73 14.86 13.11 12.24 11.36 Input kW. 8.45 6.76 5.64 5.35 5.07 4.79 4.51 3.94 Capacity kW 24.62 19.70 16.42 14.77 13.95 12.31 11.49 10.67 Input kW. 7.94 6.35 5.29 5.03 4.76 4.50 4.23 3.70 Capacity kW 22.80 18.24 15.20 13.68 12.92 11.40 10.64 9.88 Input kW. 7.35 5.88 4.90 4.66 4.41 4.17 3.92 3.43 Capacity kW 20.98 16.78 13.98 12.59 11.89 10.49 9.79 9.09 Input kW. 6.76 5.41 4.51 4.28 4.06 3.83 3.61 3.16 Capacity kW 18.24 14.59 12.16 10.94 10.34 9.12 8.51 7.90 Input kW. 5.88 4.70 3.92 3.72 3.53 3.33 3.14 2.74 15ºC 18ºC 20ºC 22ºC 27ºC Model: YOHC -60 Cooling OUTDOOR TEMPERATURE DRY Indoor 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC Total capacity kW 16.42 15.71 15.14 14.28 13.71 13.28 12.85 Sensitive capacity kW 13.14 12.57 12.11 11.42 10.97 10.62 10.28 Input kW. 3.78 4.32 4.86 5.40 5.94 6.48 7.02 Total capacity kW 17.99 17.20 16.58 15.64 15.01 14.55 14.08 Sensitive capacity kW 14.39 13.76 13.26 12.51 12.01 11.64 11.26 Input kW. 3.99 4.56 5.13 5.70 6.27 6.84 7.41 Total capacity kW 19.55 18.70 18.02 17.00 16.32 15.81 15.30 Sensitive capacity kW 15.64 14.96 14.42 13.60 13.06 12.65 12.24 Input kW. 4.20 4.80 5.40 6.00 6.60 7.20 7.80 Total capacity kW 22.48 21.51 20.72 19.55 18.77 18.18 17.60 Sensitive capacity kW 17.99 17.20 16.58 15.64 15.01 14.55 14.08 Input kW. 4.83 5.52 6.21 6.90 7.59 8.28 8.97 Conditions 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Indoor 24ºC D 12ºC D 7ºC D 4ºC D 0ºC D -5ºC D -7ºC D -15ºC D Conditions 18ºC W 11ºC W 6ºC W 3ºC W -1ºC W -6ºC W -8ºC W -16ºC W Capacity kW 34.50 27.60 23.00 20.70 19.55 17.25 16.10 14.95 Input kW. 10.35 8.28 6.90 6.56 6.21 5.87 5.52 4.83 Capacity kW 32.40 25.92 21.60 19.44 18.36 16.20 15.12 14.04 Input kW. 9.72 7.78 6.48 6.16 5.83 5.51 5.18 4.54 Capacity kW 30.00 24.00 20.00 18.00 17.00 15.00 14.00 13.00 Input kW. 9.00 7.20 6.00 5.70 5.40 5.10 4.80 4.20 Capacity kW 27.60 22.08 18.40 16.56 15.64 13.80 12.88 11.96 Input kW. 8.28 6.62 5.52 5.24 4.97 4.69 4.42 3.86 Capacity kW 24.00 19.20 16.00 14.40 13.60 12.00 11.20 10.40 Input kW. 7.20 5.76 4.80 4.56 4.32 4.08 3.84 3.36 15ºC 18ºC 20ºC 22ºC 27ºC 8. Air Velocity and Temperature Distributions Discharge angle 60° (CEILING) Airflow velocity Temperature Discharge angle 60°(FLOOR) Airflow velocity Temperature 9. Electric Characteristics Power supply Model Indoor fan motor Hz Voltage Power output FLA YOKC-12 50 220~240 25 0.13 YOKC-18 50 220~240 55 0.355 YOKC -24 50 220~240 55 0.355 YOKC-30 50 220~240 80 0.475 YOKC-36 50 380 80 0.475 YOKC-48 50 380 59 0.34 YOKC-60 50 380 59 0.34 Symbols: FLA: Full Load Amps. 10. Sound Levels Ceiling Floor High airflow ¸ ß · ç µ Í· ç Low airflow Sound pressure level dB£ 0̈dB=0.0002¦ Ìbar£ © Sound pressure level dB£ 0̈dB=0.0002¦ Ìbar£ © 12000btu/h 18000btu/h Audibility limits of continuous white sound Octave band center frequency£ Ḧz£ © Ceiling Audibility limits of continuous white sound Octave band center frequency£ Ḧz£ © Floor Sound pressure level dB£ 0̈dB=0.0002¦ Ìbar£ © Sound pressure level dB£ 0̈dB=0.0002¦ Ìbar£ © 24000btu/h 30000btu/h 36000btu/h A udibility lim its of continuous w hite sound Audibility limits of continuous white sound O ctave band center frequency £ Ḧ z £ © Octave band center frequency £ Ḧz £ © Ceiling Floor Sound pressure level dB£ 0̈dB=0.0002¦ Ìbar£ © Sound pressure level dB£ 0̈dB=0.0002¦ Ìbar£ © 48000btu/h 60000btu/h Audibility limits of continuous white sound Octave band center frequency£ Ḧz£ © Ceiling Audibility limits of continuous white sound Octave band center frequency£ Ḧz£ © Floor 11. Exploded view 11.1 YOKC-12 No. YOKC-18 YOKC -24 Part Name Quantity No. Part Name Quantity 1 Air inlet grille 1 20 Installation clamp 2 2 filter 2 21 Right holder,eva 1 3 Electric control assy 1 22 Base pan 1 3.1 Electric part box 1 23 Evaporator 1 3.2 Wire joint 1 23.1 Electric expansive valve 1 3.3 Wire joint “ROHS” 1 23.2 Electric Expansion loop 1 3.4 Pipe Temperature Sensor Ass'y II 1 24 left holder, eva 1 3.5 Pipe Temperature Sensor Ass'y 1 25 left fixed board, eva 1 3.6 Transformer 1 26 left frame holder, eva 1 3.7 Main control PCB 1 27 left clapboard 1 3.8 Fan motor capacitor 1 28 right installation board 1 4 Cover for E-box 1 29 right clapboard 1 5 Panel Ass'y 1 30 middle beam 1 6 Display panel box 1 31 grille lock 1 7 Display PCB assy 1 32 fan motor 1 8 Manual button 1 33 grille strip 2 9 Sealing foam I for air out frame 1 34 grille strip screw 2 10 Sealing foam II for air out frame 2 35 Sroll-shell, down 2 11 Sealing foam III for air out frame 1 36 Sroll-shell, up 2 12 Air-out frame assy 1 37 fan 2 13 Back clapboard 1 38 left fixing clamp for motor 1 14 wiry holder for water collector 1 39 right fixing clamp for motor 1 15 Collect water pan assy 1 40 Strenghten board for motor 1 16 plastic cover 1 41 left installation board 1 17 base pan frame assy 1 42 holder 1 18 Right frame holder, eva 1 43 Remote Controller 1 19 Right fixed board, eva 1 11.2 YOKC-30 No. YOKC-36 Part Name Quantity No. Part Name Quantity 1 Air inlet grille 1 21 Right holder,eva 1 2 filter 3 22 Base pan 1 3 E-Parts box ass'y 1 23 Evaporator 1 3.1 Electric part box 1 24 left holder, eva 1 3.2 Wire joint 1 25 left fixed board, eva 1 3.3 Wire joint 1 26 left frame holder, eva 1 3.4 Pipe temp. sensor ass'y 1 27 left clapboard 1 3.5 Room temp. sensor ass'y 1 28 right installation board 1 3.6 Transformer 1 29 right clapboard 1 3.7 Main control PCB 1 30 middle beam 1 3.8 Fan motor capacitor 1 31 grille lock 2 4 Cover for E-box 1 32 fan motor 1 5 Panel ass'y 1 33 grille strip 2 6 Display panel box 1 34 grille strip screw 2 7 Display board ass'y 1 35 Sroll-shell, down 3 8 Manual button 1 36 Sroll-shell, up 3 9 Sealing foam I for air out frame 1 37 fan 3 10 Sealing foam II for air out frame 3 38 left fixing clamp for motor 1 11 Sealing foam III for air out frame 1 39 right fixing clamp for motor 1 12 Air-out frame assy 1 40 Strenghten board for motor 1 13 Back clapboard 1 41 left installation board 1 14 wiry holder for water collector 1 42 Supporting board for bearing 1 15 Collect water pan assy 1 43 bearing underlay 1 16 plastic cover 1 44 Axis 1 17 base pan frame assy 1 45 Fixing board for bearing 1 18 Right frame holder, eva 1 46 Coupling 1 19 Right fixed board, eva 1 47 holder 1 20 Installation clamp 2 48 Remote Controller 1 11.3 YOKC-48 No. YOKC-60 Part Name Quantity No. Part Name Quantity 1 Air inlet grille 2 23 left sealing board 1 2 filter 4 24 left clapboard 1 3 left fixing clamp for motor 2 25 E-Parts box ass'y 1 4 right fixing clamp for motor 2 25.1 Wire joint 1 5 Strenghten board for motor 2 25.2 Wire joint 1 6 E-part box underlay 1 25.3 Pipe temp. sensor ass'y 1 7 Sroll-shell, down 4 25.4 Room temp. sensor ass'y 1 8 Sroll-shell, up 4 25.5 Transformer 1 9 fan 2 25.6 Main control PCB 1 10 fan motor 2 25.7 Fan motor capacitor 2 11 fan motor holder 2 25.8 Electric part box 1 12 right holder, filter 2 26 Cover for E-box 1 13 left holder, filter 2 27 Collect water pan ass'y 1 14 middle beam 1 28 cover 1 15 pipe fixed board 1 29 Display board ass'y 1 16 Sealing foam for collect pan 2 30 Display panel box 1 17 Installation clamp 2 31 Sealing foam I for air out frame 2 18 right clapboard 1 32 Air-out frame assy 1 19 right sealing board 1 33 Evaporator 1 20 right installation board 1 34 plastic cover 1 21 Base pan ass'y 1 35 holder 1 22 left installation board 1 36 Remote Controller 1 Part 3 Outdoor Units Outdoor Units……………………………………………………………….. Outdoor Units 1. Dimensions…………………………………………………………………………………….. 2. Service Space………………………………………………………………………………….. 3. Wiring Diagrams………………………………………………………………………………. 4. Field Wiring…………………………………………………………………………………….. 4. Electric Characteristics……………………………………………………………………… 6. Operation Limits………………………………………………………………………………. 7. Sound Levels………………………………………………………………………………….. 8. Exploded view…………………………………………………………………………………. 9. Troubleshooting………………………………………………………………………………. 1. Dimensions 1.1 YOJC-12 750 590 285 290 315 62 530 12. 5 1.2. YOJC-18 110 1.3. YOJC-24 895 860 330 62 590 1.4. YOJC-30 YOJC-36 141 1.5. YOJC-48 YOJC-60 2. Service Space Capacity≤60000Btu Obstacle >30cm Air inlet >30cm >60cm (Wall or obstacle) Air inlet Fix with bolt Maintain channel >200cm >60cm Air outlet Deep foundation Necessary width 600mm M10 bolt 4pieces per unit 3. Wiring diagrams 3.1 Cooling & Heating 3.1.1. YOJC-12 3.1.2. YOJC-18 3.1.3. YOJC-24 3.1.4. YOJC-30 RES 2 1 L N 1 2 3 5 4 STARTI NGCAPACI TOR STARTI NGRELAY WARNI NG: I F THE I NDOOR UNI T I S T1&T2&DL SERI ES, PLEASE PUT THE LI NES ON XT3 TO I NDOOR UNI T XT1' S CORRELATI VE PART! RES DI SCHARGE RESI STANCE 3.1.5. YOJC-36 3.1.6. YOJC-48 YOJC-60 CN206 S. V. W HI TE BLUE RED( A1) YELLOW BLUE( S. V) BLUE BLUE( N) RED( A1) XT5 CN200 CN 100 BLUE( N) CN201 BLUE( S. V) BLACK( HI ) XP9 XS8 XP8 RT3 RT1 BACK( HI ) RED( LOW ) CN203 CN208 T5 H- PRO K1 BLACK( L1) A1 1 3 KM1 A2 2 4 5 6 21 22 FAN3 RED YELLOW BLACK( L3) BLACK( L2) W COMP V BLACK( L1) U HEAT W HI TE CAP3 FAN4 RED BLUE BLUE( N) YELLOW BLUE( N) RED COLD MODULE 1 2 3 4 5 Y/ G BLUE( N) RED XT2 XT1 ABCN RT5 4 TO I NDOOR UNI T FAN CAP. S. V 4- W AY VALUE KM1 AC CONTACTOR HEAT CRANK H- PRO RT3 XS8- 9 HI GH PRESSURE SW I TH RT4 XT1 T5 RT5 BLACK BLACK TO I NDOOR UNI T Y/ G OUTDOOR FAN CAP3 CAP4 XP8- 9 CN100- 208 K1 XT7 CAP4 BLUE XT6 COMPRESSOR FAN3 FAN4 PI PE TEMP. SENSOR CONNECTORS CONNECTORS P. C. BOARD SOCKETS TEMP. PROTECT SW I TH ROOMTEMP. SENSER 5- W AY TERMI NAL TRANSFORMER TEMP. SENSER 4. Field Wiring 5. Electric Characteristics Power supply Model Compressor Outdoor fan motor Hz Voltage MSC RLA Power output FLA YOJC-12 50 220~240 26 5.3 24 0.27 YOJC -18 50 220~240 36.8 8.75 53 0.61 YOJC -24 50 220~240 61 11.4 53 0.66 YOJC -30 50 220~240 97 17.65 250 1.38 YOJC -36 50 380 61 6.58 250 1.38 YOJC -48 50 380 66 8.22 65 0.7 YOJC -60 50 380 67 9.77 65 0.7 Symbols: MSC: Max. Starting Current RLA: Rated Locked Current FLA: Full Load Amps. 6. Operation Limits Ensure the operating temperature is in allowable range. Heating Cooling 24 Ambient temp. (ºC) 45 STD 35 STD 6 17 With low ambient temp. cooling module -7 -7 17 24 30 Indoor temp. (ºC) 17 24 30 Indoor temp. (ºC) 7. Sound levels 1m Microphone 12000btu/h 18000btu/h 24000btu/h 48000btu/h & 60000btu/h 3000btu/h & 36000btu/h 8. Exploded view 8.1 Cooling & Heating 8.1.1 YOJC-12 No. Part Name Quantity No. Part Name Quantity 1 Clamp for front net 6 15 Capacitor clamp 1 2 Front net 1 16 Wire joint,5p 1 3 Front clapboard 1 Wire joint, 2p 1 4 Propeller fan 1 17 Left supporter 1 5 Fan motor 1 18 Separating board 1 6 Holder for fan motor 1 19 Condenser 1 7 Chassis 1 20 Water collector 1 8 Compressor 1 21 Right clapboard 1 9 Installation plate for valves 1 22 Big handle 1 10 Gas pipe valve 1 23 Cover 1 4-way valve 1 24 Small handle 1 11 Liquid pipe valve 1 25 Rear net 1 12 Fan motor capacitor 1 26 Copper nut, TLM-C03 1 13 Installation board for E-parts 1 27 Copper nut, TLM-A01 1 14 Compressor capacitor 1 28 Pipe temp sensor ass'y 1 8.1.2 YOJC-18 No. Part Name Quantity No. Part Name Quantity 1 Clamp for front net 8 19 Wire joint 1 2 Front net 1 20 Separating board 1 3 Front clapboard 1 21 Installation board for E-parts 1 4 Propeller fan 1 22 Washer for wire joint 1 5 Fan motor 1 23 Clamp for wiring 1 6 Holder for fan motor 1 24 Compressor capacitor 1 7 Foam over holder for motor 1 25 Capacitor clamp 1 8 Cover 1 26 Chassis 1 9 Little handle 1 27 Front right clapboard 1 10 Condenser 1 28 Compressor 1 11 Support board for motor holder 1 29 Liquid valve assy 1 12 Left clapboard 1 30 Liquid pipe valve 1 13 Rear net 1 31 4-Ways valve assy 1 14 Rear right clapboard 1 Gas pipe valve 1 15 Big handle 1 Four-way Valve 1 16 Installation plate for valves 1 33 Copper nut, TLM-A01 1 17 Water collector 1 34 Copper nut, TLM-C03 1 18 Fan motor capacitor 1 32 8.1.3 YOJC-24 No. Part Name Quantity No. Part Name Quantity 1 Front net 1 20 AC contactor 1 2 Cabinet,Front 1 21 Capacitor,Fan Motor 1 3 Fan,Propeller 1 22 Wire 1 4 Fan Motor 1 5 Mount,Fan Motor 1 6 Topcap Ass'y 1 24 Compressor 1 7 Condenser Ass'y 1 25 Fixture,Segregator 1 8 Inlet Pipe for Condenser 1 4-way Valve 1 9 Outlet Pipe for Condenser 1 4-way Valve Solenoid 1 10 Rear Net 1 27 Liquid pipe valve 1 11 Support board,Back side 1 28 Capillary pipe 1 12 Handle 2 29 Gas pipe valve 1 13 Separating board 1 30 refrigerant Container 1 14 Base Pan Ass'y 1 31 Pipe temp. sensor assy 1 15 Cabinet,Front-Right 1 32 Support board, Left Side 1 16 Capacitor Clamp 1 33 Big handle 1 17 Capacitor, Compressor 1 34 Filter 1 Wiring Installation Panel 1 35 Small Handle 1 Washer for wire joint 1 36 Copper nut, TLM-B02 1 Terminal install board 1 37 Copper nut, TLM-D04 1 Terminal Block,2p 1 18 19 23 26 Clamp Terminal Block,5p 1 Terminal Block,2p 1 8.1.4 YOJC-30 No. Part Name Quantity No. Part Name Quantity 1 Clamp for front net 10 20 Fan motor capacitor 1 2 Front net 1 21 Installation board for E-parts 1 3 Front clapboard 1 22 AC contactor 1 4 Propeller fan 1 23 Main control box 1 5 Fan motor 1 24 Wire joint for multiplexer 2 6 Holder for fan motor 1 25 Wire joint for multiplexer 1 7 Chassis 1 26 Washer for wire joint 1 8 Separating board 1 27 Wire clamp 1 9 Cover 1 28 Wire joint for power 1 Condenser I 1 29 Liquid valve assy 1 Condenser II 1 30 Liquid valve 1 11 Support board for motor holder 1 31 4-way valve assy 1 12 Left supporting bar 1 32 4-way Valve 1 13 Rear net 1 33 Gas valve 1 14 Rear right clapboard 1 34 Compressor 1 15 Big handle 1 35 Discharge temp sensor 1 16 Installation plate for valves 1 36 Front right clapboard 1 17 Pipe temp sensor 1 37 Copper nut, TLM-C03 1 18 Refrigerant container 1 38 Copper nut, TLM-E05 1 19 Container clamp 1 10 8.1.5 YOJC-36 No. Part Name Quantity No. Part Name Quantity 1 Clamp for front net 10 20 Fan motor capacitor 1 2 Front net 2 21 Installation board for E-parts 1 3 Front clapboard 1 22 AC contactor 1 4 Propeller fan 1 23 Main control board,Outdoor unit 1 5 Fan motor 1 24 Wire joint for multiplexer 2 6 Holder for fan motor 1 25 Wire joint for multiplexer 1 7 Chassis 1 26 Washer for wire joint 1 8 Separating board 1 27 Wire clamp 1 9 Cover 1 28 Wire joint for power 1 Condenser I 1 29 Liquid valve assy 1 Condenser II 1 30 Liquid valve 1 11 Support board for motor holder 1 31 4-way valve assy 1 12 Left supporting bar 1 32 4-way valve 1 13 Rear net 1 33 Gas valve 1 14 Rear right clapboard 1 34 Compressor 1 15 Big handle 1 35 Discharge temp sensor 1 16 Installation plate for valves 1 36 Front right clapboard 1 17 Pipe temp sensor 1 37 Copper nut, TLM-C03 1 18 Refrigerant container 1 38 Copper nut, TLM-E05 1 19 Container clamp 1 10 8.1.6 YOJC-48 No. Part Name Quantity No. Part Name Quantity 1 Front net 2 17 Capacitor,Fan Motor 2 2 Cabinet,Front 1 18 Terminal 3 3 Fan,Propeller 2 19 AC contactor 1 4 Fan Motor 2 20 Low Pressure Valve 1 5 Room temp. sensor,outdoor 1 21 PCB board,outdoor unit 1 6 Mount,Fan Motor 1 22 Terminal 1 7 Topcap 1 23 Wire joint for power 1 Condensator I 1 24 Compressor 1 Condensator II 1 25 Refrigerator Container 1 9 Left Side Cabinet 1 26 Fixture,Segregator 1 10 Supporter, Rear Cabinet 1 Four-way Valve 1 10 Supporter, Rear Cabinet 1 Four-way Valve Solenoid 1 11 Cabinet,Back side 1 28 Low Pressure Valve 1 12 Handle 2 29 Capillary 1 13 Plate,Sound-proof 1 30 Electric heat belt for comp 1 14 Base 1 31 Discharge temp controller 1 15 Cabinet,Front Side 1 32 Pipe temp. sensor 1 16 E-control box, assy 1 8 Ass'y Pan Ass'y 27 Block,2p Block,3p Tube Ass'y 8.1.7 YOJC-60 No. Part Name Quantity No. Part Name Quantity 1 Guard fan 2 17 Capacitor,Fan Motor 2 2 Cabinet,Front 1 18 Terminal 3 3 Fan,Propeller 2 19 AC contactor 1 4 Fan Motor 2 20 Low Pressure Valve . 1 5 Room temp. sensor,outdoor 1 21 PCB board,outdoor unit 1 6 Mount,Fan Motor 1 22 Terminal 1 7 Topcap 1 23 Wire joint for power 1 Condensator I 1 24 Compressor 1 Condensator II 1 25 Refrigerator Container 1 9 Left Side Cabinet 1 26 Fixture,Segregator 1 10 Supporter, Rear Cabinet 1 4-way Valve 1 10 Supporter, Rear Cabinet 1 4-way Valve Solenoid 1 11 Cabinet,Back side 1 28 Low Pressure Valve 1 12 Handle 2 29 Capillary 1 13 Plate,Sound-proof 1 30 Electric heat belt for comp 1 14 Base 1 31 Discharge temp controller 1 15 Cabinet,Front Side 1 32 Pipe temp. sensor 1 16 E-control box, assmy 1 8 Ass'y Pan Ass'y 27 Block,2p Block,4p Tube Ass'y 9. Troubleshooting 9.1 Indoor unit’s LED indication of trouble NO. Protection or Malfunction Operation Timer lamp lamp 1 Indoor temp. sensor abnormal 2 Indoor heat exchanger sensor abnormal 3 Outdoor heat exchanger sensor abnormal 4 Outdoor abnormal 5 EEPROM abnormal ×——Extinguish ; Defrosting lamp × × × Auto recover × Yes × Yes × Yes Yes × No ——Flash at 5Hz 9.2 LEDs’ for the indication of outdoor trouble YOJC-36, YOJC -48, YOJC -60 Type Contents LED1 LED2 LED3 Flash Off Off Off Off Flash Protection Phase sequence Protection Overload of current Protection Lack of phase Flash Off Off Protection Protection of pressure Flash Flash Off Protection Open-circuit and short-circuit trouble of T3 Off Flash Flash Protection Open-circuit and short-circuit trouble of T4 Off Flash Off Protection High temperature protection of condenser Flash Flash Flash 9.2.1 Phase sequence error: Phase sequence error Change the order of two of the wires to power supply. Switch on the unit again. If the problem can not be solved, the outdoor PCB is defective 9.2.2 Overload of current Overload of current Check the current, normally The max. current for YOHC-36 is 9.4 A The max. current for YOHC-48 is 10.9A The max. current for YOHC-60 is 13.2A Is the current in rated range? No Yes The outdoor PCB is defective Possible reason 1. Outdoor fan is defective 2. The compressor is defective 3. Refrigerant is over charged 4. Air enter the refrigerant system 5. Heat exchanger is too dirty 9.2.3 Lack of phase Lack of phase Check the power supply, is it 3 phase, Yes Check the connection between power supply and terminal, Yes Outdoor PCB is defective 9.2.4 Protection of pressure or temp. Protection of pressure or temp. Yes Is it k1 or K2 open ? Is temp. protective switch K1 Yes Possible reason 1. The wires is loose to K1 2. Air or other gas in the refrigerant. 3. Heat exchanger is dirty 4. Outdoor fan or fan blade is defective 5. Outdoor unit is bad ventilation 6. Refrigerant is leakage Is pressure protective switch K2 Yes Possible reason 1. The wires is loose to K2 2. Air or other gas in the refrigerant. 3. Heat exchanger is dirty 4. Outdoor fan or fan blade is defective 5. Outdoor unit is bad ventilation 6. Refrigerant is two much 9.2.5 Open-circuit and short-circuit trouble of T3 Is connection to connector of temp. sensor good? No Yes Repair connector Check the resistance of the temp. sensor according to Annex 1 Is it the resistance is normal? No Yes Indoor PCB is defective. Replace the sensor 9.2.6 Open-circuit and short-circuit trouble of T4 Is connection to connector of temp. sensor good? No Yes Check the resistance of the temp. sensor according to Annex 1 Is it the resistance is normal? Yes Indoor PCB is defective. No Replace the sensor Repair connector 9.2.7 High temperature protection of condenser High temperature protection of condenser Check the resistance of the temp. sensor according to Annex 1, is it normal? Yes Possible reason 1. Air or other gas in the refrigerant. 2. Heat exchanger is dirty 3. Outdoor fan or fan blade is defective 4. Outdoor unit is bad ventilation 5. Refrigerant is leakage No Replace the sensor 9.3 Troubles and Solutions If any the following abnormal conditions occur, turn off the power supply immediately. Please contact our dealer. TROUBLES Indicator lamps flash rapidly, after your disconnecting and connecting the unit, the situation is the same. Fuse or circuit breaker work frequently. Foreign matter or water has fallen into the unit. Remote controller is disabled or the switch is out of hand. Any other unusual conditioner is observed. If any of the following conditions occur, check your unit and resolve corresponding problems referring to given remediation. If the trouble can't be settled contact our dealer. Trouble Unit does not start Air flowing normally with low cooling (heating) effect Cause Solutions Power failure. Wait for the comeback of power Power switch is open. Switch on the power Fuse of power switch may have blown. Replace the fuse Batteries of remote controller are exhausted. Replace the batteries The time is not start-up time you have set. Wait or cancel the time set. Temperature is not set correctly. Set the temperature properly. Door or window is open. Close door and window. Air filter is blocked with dust or dirtiness. Clean the air filter. Inlet/outlet blocked. of indoor/outdoor units are Clear all blockages. Inlet/outlet blocked. of indoor/outdoor units are Clear the blockage, then restart your operation. Be in 3 minutes protection of compressor Wait NOTE: Do not replace electric wire or repair the air conditioner by yourself to avoid possible danger. 9.4 Troubles and solutions concerning the remote controller Please make the following check before asking for repair or maintenance. Trouble CAN NOT CHANGE THE FAN SPEED SETTING Cause Solutions Check if the mode display on the LCD is AUTO The lndoor Unit will select fan speed automatically when AUTO mode is selected. Check if the mode display on the LCD is DRY The lndoor Unit will select fan speed automatically when the unit is on DRY mode. The transmission symbol does not flash Symptom Checking items Cause Press ON/OFF button, the remote controlling signals can not be transmitted Check if the remote controller has run out of power When the battery was out, transmission signals can not be sent Temperature display disappear Symptom Checking items Temperature Display does not light. Check if the mode display on the LCD is FAN ONLY Cause You can not set the temperature when the unit is on FAN ONLY mode. The Display Goes Off Symptom Checking items Cause The indication on the display disappears after a lapse of time. Check whether the timer operation has come to an end when the OFF TIMER is indicated on the display. The air conditioner operation stops since the set time elapsed. The ON TIMER indicators go off after a lapse of certain time. Check whether the timer operation is started when the ON TIMER is indicated on the display. When the time set to start the air conditioner is reached, the air conditioner will automatically start and the appropriate indicator will go off. The Signal Receiving Tone does Not Sound Symptom Checking items Cause No receiving tone sounds from the indoor unit even when the ON/OFF button is pushed. Check whether the signal transmitter of the remote controller is properly directed to the receiver of the indoor unit when the ON/OFF button is pushed. Direct the signal transmitter of the remote controller to the receiver of the indoor unit, and then repeatly push the ON/OFF button twice. Buttons on the remote controller don't work. Press Reset button. Part 4 Installation Installation…………………………………………………………………… 1. Refrigerant pipe installation 1.1. Measure the necessary length of the connecting pipe, and make it by the following way. a. Connect the indoor unit at first, then the outdoor unit. Bend the tubing in proper way. Do not harm them. CAUTIONS: Daub the surfaces of the flare pipe and the joint nuts with frozen oil, and wrench it for 3~4 rounds With hands before fasten the flare nuts. Be sure to use two wrenches simultaneously when you connect or disconnect the pipes. Tubing size Torque 6.35 1420~1720N.cm(144~176kgf.cm) 9.52 3270~3990N.cm(333~407kgf.cm) 12.7 4950~6030N.cm(504~616kgf.cm) 16 6180~7540N.cm(630~770kgf.cm) 19 9720~11860N.cm(990~12106kgf.cm) b. The stop value of the outdoor unit should be closed absolutely (as original state). Every time you connect it, first loosen the nuts at the part of stop value, then connect the flare pipe immediately (in 5 minutes). If the nuts have been loosened for a long time, dusts and other impurities may enter the pipe system and may cause malfunction later. So please expel the air out of the pipe with refrigerant before connection. c. Expel the air after connecting the refrigerant pipe with the indoor unit and the outdoor unit. Then fasten the nuts at the repair-points. 1.2. Locate The Pipe a. Drill a hole in the wall (suitable just for the size of the wall conduit), then set on the fittings such as the wall conduit and its cover. b. Bind the connecting pipe and the cables together tightly with binding tapes. Do not let air in, which will cause water leakage by condensation. c. Pass the bound connecting pipe through the wall conduit from outside. Be careful of the pipe allocation to do no damage to the tubing. 1.3. Connect the pipes. 1.4. Then, open the stem of stop values of the outdoor unit to make the refrigerant pipe connecting the indoor unit with the outdoor unit in fluent flow. 1.5. Be sure of no leakage by checking it with leak detector or soap water. 1.6. Cover the joint of the connecting pipe to the indoor unit with the soundproof / insulating sheath (fittings), and bind it well with the tapes to prevent leakage. 2. Vacuum dry and leakage checking 2.1. Vacuum Dry: use vacuum pump to change the moisture (liquid) into steam (gas) in the pipe and discharge it out of the pipe to make the pipe dry. Under one atmospheric pressure, the boiling point of water(steam temperature) is 100 . Use vacuum pump to make the pressure in the pipe near vacuum state, the boiling point of water falls relatively. When it falls under outdoor temperature, the moisture in the pipe will be vaporized. 2.2. Vacuum dry procedure There are two methods of vacuum dry due to different construction environment: common vacuum dry, special vacuum dry. . Common vacuum dry procedure Vacuum dry (for the first time)---connect the all-purpose detector to the inlet of liquid pipe and gas pipe, and run the vacuum pump more than two hours (the vacuum pump should be below -755mmHg) If the pump can’t achieve below -755mmHg after pumping 2 hours, moisture or leakage point will still exist in the pipe. At this time, it should be pumped 1 hour more. If the pump can’t achieve -755mmHg after pumping 3 hours, please check if there are some leakage points. Vacuum placement test: place 1 hour when it achieves -755mmHg, pass if the vacuum watch shows no rising. If it rises, it shows there’s moisture or leakage point. Vacuuming from liquid pipe and gas pipe at the same time. Sketch map of common vacuum dry procedure. Special vacuum dry procedure This vacuum dry method is used in the following conditions: There’s moisture when flushing the refrigerant pipe. Rainwater may enter into the pipe. Vacuum dry for the first time ······ 2h pumping . Vacuum destroy for the second time ······ Fill nitrogen to 0.5Kgf/cm2 Because nitrogen is for drying gas, it has vacuum drying effect during vacuum destroy. But if the moisture is too much, this method can’t dry thoroughly. So, please pay more attention to prevent water entering and forming condensation water. . Vacuum dry for the second time······1h pumping Determinant: Pass if achieving below -755mmHg. If -755mmHg can’t be achieved in 2h, repeat procedure and . . Vacuum placing test ······ 1h . Sketch map of special vacuum dry procedure 3. Additional charge 3.1. When the length of the one-way pipe is less than 5m, additional refrigerant charge after vacuuming is unnecessary. 3.2. When the length of one-way pipe is over 5m, the additional charge quantity is as follows (unit in gram): Calculation method Refrigerant R410A Liquid diameter mm Unit amount (g/m) Formula Φ6.35 30 (L-5)×30 Φ9.53 65 (L-5)×65 Φ12.7 90 (L-5)×90 Remark 1 The additional refrigerant charge is simply related with the liquid pipe diameter. 2 In the up formula, “L” means total length of liquid pipe(unit: m). 4. Water drainage 4.1. Gradient and Supporting 4.1.1 Keep the drainpipe sloping downwards at a gradient of at least 1/100. Keep the drainpipe as short as possible and eliminate the air bubble. 4.1.2 The horizontal drainpipe should be short. When the pipe is too long, a prop stand must be installed to keep the gradient of 1/100 and prevent bending. Refer to the following table for the specification of the prop stand. Hard PVC pipe Diameter Distance between the prop stands 25~40mm 1.5~2m 4.1.3. Precautions The diameter of drainpipe should meet the drainage requirement at least. The drainpipe should be heat-insulated to prevent atomization. Drainpipe should be installed before installing indoor unit. After powering on, there is some water in water-receiver plate. Please check if the drain pump can operate correctly. All connection should be firm. Wipe color on PVC pipe to note connection. Climbing, horizontal and bending conditions are prohibited. The dimension of drainpipe can’t less than the connecting dimension of indoor drainpipe. Heat-insulation should be done well to prevent condensation. Indoor units with different drainage type can’t share one convergent drainpipe. 4.2 Drainpipe Trap 4.2.1. If the pressure at the connection of the drainpipe is negative, it needs to design drainpipe trap. 4.2.2. Every indoor unit needs one drainpipe trap. 4.2.3. A plug should be designed to do cleaning. 50cm 50cm Pl ug 4.3 Upwards drainage(drain pump) 4.3.1. To ensure the gradient 1/100, the drainpipe can be lifted to 340mm. After upwards, place downwards, or it will cause malfunction to drain pump. 4.4 Convergent drainage 4.4.1. The number of indoor units should be as small as possible to prevent the traverse main pipe overlong. 4.4.2. Indoor unit with drain pump and indoor unit without drain pump should be in different drainage system. 4.4.3. Selecting the diameter Number of connecting indoor units→Calculate drainage volume→Select the diameter Calculate allowed volume =Total cooling capacity of indoor units(HP)×2 (l/ hr) Hard Hard Hard Hard Hard Allowed volume(lean 1/100) (l/ hr) ≤14 14 ≤88 88 ≤334 175 ≤334 334 I.D. (mm) Ø 25 Ø 30 Ø 40 Ø 50 Ø 80 Thick 3.0 3.5 4.0 4.5 6.0 4.5 Drainage test Drainage without drain pump After finishing drainpipe installation, pour some water into the water receiver plate to check if the water flows smoothly. 5. Insulation work 5.1 Insulation material and thickness 5.1.1. Insulation material Insulation material should adopt the material which is able to endure the pipe’s temperature: no less than 70 in the high-pressure side, no less than 120 in the low-pressure side(For the cooling type machine, no requirements at the low-pressure side.) Example: Heat pump type----Heat-resistant Polyethylene foam (withstand above 120 ) Cooling only type---- Polyethylene foam (withstand above 100 ) 5.1.2. Thickness choice for insulation material Insulation material thickness is as follows: Pipe diameter (mm) Adiabatic material thickness Φ6.4—Φ25.4 10mm Φ28.6—Φ38.1 15mm Inner diameterΦ20—Φ32 6mm Refrigerant pipe Drainage pipe 5.2 Refrigerant pipe insulation 5.2.1. Work Procedure Before laying the pipes, the non-jointing parts and non-connection parts should be heat insulated. When the gas proof test is eligible, the jointing area, expanding area and the flange area should be heat insulated 5.2.2. Insulation for non-jointing parts and non-connection parts wrong Gas pipe and liquid pipe should right Insulate the gas pipe (cooling only) Insulate the gas pipe and liquid pipe For construction convenience, before laying pipes, use insulation material to insulate the pipes to be deal with, at the same time, at two ends of the pipe, remain some length not to be insulated, in order to be welded and check the leakage after laying the pipes. 5.2.3. Insulate for the jointing area, expanding area and the flange area Insulate for the jointing area, expanding area and the flange area should be done after checking leakage of the pipes Make sure there’s no clearance in the joining part of the accessorial insulation material and local preparative insulation material. 5.3 Drainage pipe insulation The connection part should be insulated, or else water will be condensing at the non-insulation part. 5.4 Note 5.4.1 The jointing area, expanding area and the flange area should be heat insulated after passing the pressure test 5.4.2 The gas and liquid pipe should be heat insulated individually, the connecting part should be heat insulated individually. 5.4.3 Use the attached heat-insulation material to insulate the pipe connections (pipes’ tie-in ,expand nut ) of the indoor unit. www.johnsoncontrols.com SM-YOHC-12-60GB 03-07
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project