Installation and Operations Manual
READ AND SAVE THESE INSTRUCTIONS
AlorAir Solutions INC.
Add: 2048 E. Francis St Ontario CA 91761
Tel: 888-990-7469
E-mail: [email protected]
DERUMDIFIER.
Limited Warranty
This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the
original purchaser that this ALORAIR product is free from manufacturing defects in material
or workmanship for the limited warranty period of:
Six (6) Month parts and labor. This includes the shipments charges for replacement parts
or unit.
One (1) year parts and labor. This does not include the shipment charge to send the
defective product back to be repaired or replaced.
Three (3) years parts and labor on Refrigeration System ONLY (Compressor,
Condenser, and evaporator). Transportation cost, not included.
Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and
evaporator). Transportation cost, not included.
This limited warranty is valid only on products purchased from the manufacturer or
ALORAIR authorized dealer and operated, installed, and maintained according to the
instructions included in this user guide or furnished with the product. Alorair Solutions Inc
will not provide in-home service during or after the warranty period. You may be responsible
for the shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact ALORAIR at 888-990-7469 or
[email protected]. A proof of purchase or order number is required to receive warranty
service. During the applicable warranty period, a product will be repaired or replaced at the
sole option of ALORAIR.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship
encountered in normal household, commercial or noncommercial use of this product and
shall not cover the following:
e Damage occurs in uses for which this product was not intended for.
e Damage caused by unauthorized modification or alteration of the product.
+ Cosmetic damage including scratches, dents, chips, and other damage to the
product’s finishes.
e Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other
acts of nature.
+ Damage caused by incorrect electrical line current, voltage, fluctuations, and
surges.
e Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited
warranty.
DERUMIDIFIER.
Table of Contents
Safety Instructions
Identification
Electrical Supply
How the Dehumidifier Works
Guidelines
Parts Diagram
Using the Display- Main Screen
Maintenance Instructions
Troubleshooting
Warranty
10
11
DEHUMIDIFIER
Safety Instructions
e Don’t adjust or alter the unit in any way.
¢ The use of unauthorized parts will void your warranty. Contact your approved
distributor for assistance.
e Always unplug the unit prior to removing the cover.
e Inspect the power cord prior to use and do not use if it is damaged.
* The unit should only be used with a 115V/60Hz circuit protected by a GFCI outlet.
Identification
Prior to installation of the unit,write down the serial number and date of purchase. You will need
this information if you need assistance in the future. The data label on the side of your unit has
the necessary information.
Model Number: Storm SLGR 850X[_] Storm LGR 850X[_] Storm LGR 850 |
Serial Number: Date of Purchase:
For additional questions concerning your dehumidifier:
e Contact your installing contractor.
e Contact AlorAir Solutions: [email protected]
888-990-7469
Electrical Supply
Power Supply: 115V/60Hz
Outlet Requirement: 3-Prong, GFCI
Circuit protector:15 Amp
WARNING: Using a 220V outlet may cause seriou s injury from electric shock.
To reduce risk of injury:
1. Always disconnect machine from electrical power before servicing.
2. Only plug unit into a gounded electrical cicuit.
3. Do not use an extension cord.
4. Do not use a plug adapter.
Symptom
DEHUMIDIFIER
Troubleshooting
Cause
Solution
Display is Blank
No Airflow
Error Code: E1
Error Code: E4
Error Code: LO
Error Code: HI
E5 Error Code
If the unit will be stored for an extended period of time, complete the following steps:
1. Turn off the unit and allow it to to dry.
Poor Connection
Power Outage
Filter is Dirty
Air Inlet or Outlet is Blocked
Humidity Sensor or
Communication Error
Problem with Pump
Room Temperature is below
33.8 F
Room Temperature is above
110° F
Refrigerant Leak
Verify that both ends of the
power cord are plugged in
Reset power
Clean the filter
Clear the blockage
Check to ensure that the sensor
wire is connected at both ends.
if no issues are visible, the
sensor may be faulty.
Verify that the pump is properly
installed and functioning. If so,
unplug the unit for two minutes,
then restart.
Increase the room temperatue
so it is within operating range
(above 33 8° F ). If error still
displays, check sensor.
Decrease the room temperatue
so it is within operating range
(below 110° F). If error still
displays, check the sensor.
Contact Your Installer for
Assistance.
Dehumidifier Storage
2. Clean out the pump reservoir.
3. Wrap and secure the power cord.
4. Cover filter mesh.
5. Store in clean, dry space.
DEHUMIDIFIER
Maintenance Instructions
Before Use
e Check the power cord for signs of damage such as fraying. Replace the cord before use if
there is any damage.
¢ Check the filter for signs of dirt or obstructions. Clean or replace the filter as necessary.
¢ Check the coils for signs of buildup. Clean if needed.
Cleaning the Machine Body
Use a soft, damp cloth to clean the exterior of the unit. Do not use any soap or solvents.
Filter Maintenance
1. Unplug the unit.
2. Slide out the filter.
3. Check the filter for dirt
and buildup.
4. For a Pre-Filter or MERV-8:
Clean the filter mesh by
vacuuming it or washing with warm
water (no soap or cleaners).Gently shake the filter dry,
then reinsert it.
5. For a Carbon, or HEPA Filter:
If there is dirt or buildup, replace filter.
Removing the Housing
1. Remove the screws on the housing.
2. Remove the screws on the air inlet grill and
air outlet grill.
Coil Maintenance
e Once per year, clean the coils with an approved coil cleaner.
¢ Coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil
Cleaner.
Pump Maintenance
Pump Access:
Remove the screws on the housing, then lift off. Unplug the pump drain line, then remove the
screws holding the pump in place.
Cleaning the Pump Reservoir:
Once the screws are removed, lift off the top of the pump and set aside. Use a paper towel to
wipe out the base of the pump.
DERUMIDIFIER.
How the Dehumidifier Works
The dehumidifier utilizes its integral humidistat to monitor the conditioned space.
Once conditions are outside the desired setpoint, the compresser energizes and air is
drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air
so the water vapor will turns into liquid condensation. The air is then reheated through the
condenser coil and distributed back into the room.
Guidelines
Operation Notes
+ Always make sure that the unit is operated, transported, and stored on a stable surface.
¢ For maximum efficiency, operate the unit with all windows and doors closed.
e Do not place the unit anywhere that may block the inlet or outlet airflow.
Drain Hose Notes
«e The Dehumidifier is equipped with an external drain line connection, making it easy to plug in.
* The drain line can be directed outside or into any sink, drain, etc.
* For more effective draining, uncoil the entire hose before using.
* Never place the end of the hose higher than 15 feet.
e Always ensure that the drain hose is not blocked prior to use.
Transportation Notes
e Always secure the dehumidifier during transportation enter period.
¢ If the unit is transported vertically, return it to a normal horizontal position, and let sit for 30
minutes prior to use.
DEHUMIDIFIER DERUMIDIFIER.
6. Water Pump working interface display
Compressor protection time not shown:
Parts Diagram
=
ZA) 807 60% 93
PURGING SYSTEM A Important
+ Unplugging the unit without running the shutdown
CTE
Out
=» u Set
000 JOBHRS 000 LIFEHRS
sequence will allow water to remain in the unit after use.
Staring 28 second |
* Tilting the unit more than 70 degrees on the handle side or
H and le more than 20 degrees on the non-handle side may result in
water spillage.
P u rg e Cycl e * Tilting wis unit without running the final purge may result in
water spillage.
Temp/RH Sensor
“Pump working countdown”: Indicates: No matter in which
working state and interface, as long as the pump works, this
interface appears and counts down to 28 seconds.However,
the interface only displays the previous working status and
interface after 3 seconds.For example, after 3 seconds, there
is a drainage icon on the main interface and it
will flash until the drainage is finished.
Easy Cord and
Hose Storage
Air Outlet
7. Interface display in case of failure
Machine running time fault display:
Wheel
Make fault judgment and take corresponding actions after starting
up. Regardless of the state, the fault is executed first and the fault
= 1 LO H | code is displayed on the interface. If there is a fault in the
sub-menu operation, immediately return to this interface display
fault (including defrosting state). (the fault is judged when the pump
= 5 E4 works, and the fault is displayed as usual, but the pump needs to
complete the water pumping this time). Multiple faults can be
displayed at the same time.
Control Panel
Description of fault display:
Air Inlet
% Humidity sensor fault: when the humidity sensor unit fault or signal can not be transmitted, the fault is
judged to be E1. The machine is out of operation (power on again after troubleshooting). Pump button
can operate.
LUIS
+
LR
% Ambient temperature T<2: When the sensor continuously detects the ambient temperature of inlet air
T=2 degrees for 600 seconds, the fault is judged to be LO and the whole machine is stopped. Other values,
Air Filter corresponding to the temperature region operation. (recoverable). At this time, the interface cannot
be operated. The pump button can be operated.
2 @ Ambient temperature T>45: When the sensor continuously detects the inlet air environment
Condensate Drain temperature T=45 degrees for 15 seconds, the fault is judged to be HI and the whole machine is stopped.
Line Quick Connect Other values, corresponding to the temperature region operation. (recoverable). At this time, the interface
cannot be operated. The pump button can be operated.
DEHUMIDIFIER DEHLUMIDIFIER
* LCD Display Instructions *
"Humidistat Setpoint 00%":Used for setting dehumidification
mode humidity.Press ">" to set the humidity. The adjustment
SETPOINT | range of humidity setting is between 25 and 80%.
Each key rises or falls 5%, which can be recycled.
Press У» to change When the setting is completed,do not operate for 5 seconds
and begin to take effect.(Otherwise, the compressor will be
shut down immediately after it is below ambient humidity at
“CO” indicates continuous mode the time of setting.) Humidity below 25 percents "CO" mode
recyclable.The main interface displays the set parameters.
4. Main interface frosting status display: A RS
The machine will display this after defrost when running
PE | | scans 1. When the machine is powered on but not working:
Zee} 80° 60% 93» (after power on, the buzzer makes a sound)
—ALORAIR
=
DEFROSTING
Defros Shutdown
8 0" 6 0 % 9 3 o/b
In 06:00 Set
000 JOB HRS 000 LIFE HRS
UNITOFF
When the machine is running normally, “Deffrost When the user is operating in the submenu, the |
SHUTDOWN IN 06:00” will occurs in the machine is in the frosting state.At this point, the Press ©) to start
interface after defrosting. It's defrost countdown frosting interface displays 3 seconds, and returns www.alorair.com
use seconds as units. This screen displays only to the submenu program in the background
3 seconds. Displays the previous interface and countdown.When the user returns to the main Boot display: The LOGO interface The machine displays when it is not
status after restoration.If it is the home screen, interface without any operation, the frosting state la:
og: . ae . will disappear after 2 seconds. Enter working. (Power off state but have
the frost icon will flash. is displayed inthe main interface in the way of Bu nu
icon flicker. the following interface. electricity)
2. Main interface display of dehumidification state:
The following information is displayed when the machine is working:
000 JOB HRS:
Refers to the working time, which is defined as the time from
5. Compressor on waiting interface display
Compressor protection time not shown:
“Compressor ready IN 03:00” indicates : That the starting up to shutting down, including the defrost time during Ze) 80°
RESTARTING interface will be displayed when the compression is the period, and the standby time after the humidity. The x
Compressor ready in a protected state. (including power-on and shutdown, b h + functi lf not. th kina ti hall (A= sor
the humidity rises immediately after the arrival of LO submenu паз а reset tUncuon. и not, ле working time sia Où
MD OIIMA
HI, and the shutdown resu ediately after the be accumulated. Set
In 03 00 emergence of LO HI).Displays the countdown in seconds.Ifthe Total time 9999 hours, the largest cumulative to the largest IES TR
above situation does not occur within 3 minutes, it is not automatically reset after restart, and display units for hours. ie |
(round off).
shown.
DEHUMDIFIER DERUNDIFIER
e 000 LIFE HRS:
Refers to the total working time, i.e. the total working time (hours), which is in hours.(press the mode key +
select the confirmation key, and the total working time will be cleaned after 3 seconds. 3.4
¢ IN/OUT 00°F 00% 00 gr/ Ib:
Indicates the temperature, humidity and moisture content of the air inlet and outlet WIFI HOTSPOT
{GPP - grain per pound (gr/Ib)}.
‚ Set 00%: Off
Indicates set humidity.
WI-FI hotspot: Factory setting is "OFF",
press > to enable wifi hotspot and switch
ON/OFF.The device can transmit data and receive
APP commands.The icon flickers when connected
on the main interface. After successful connection,
the icon displays normally.
« If the main interface does not operate for 10 minutes, the screen will go out.Press any key to
wake up.
e Other icons light up or flicker when opened.
The total working time is the accumulation of each working time (hours) in hours. (Press the
mode key + select to confirmation key, and the total working time will be cleaned after 3 seconds.
3.Dehumidification status submenu interface display
NAME
3.1 Alorair Dehumidifier
Go to the app to change
Device name displayed on the screen:
You can change the device name on the APP
application.
JOB HOURS “Indicates”:Do | need to clear out this time?",
press ">"if you need to clear. When the operation
3.2 9999 interface and the working time of this interface
will be reset and started to be instant again.
is completed, the working time of the main
Hold > to Reset After accumulation (9999), clean up and round.
COILTEMP
“Coil Temp 000°C ”: Used to display the current
3.3 temperature of the coil. When it is below zero,
" = the "-" symbol is displayed in front. "-" is not
required on zero.
Press >> to change
3.5.1
POWER DOWN TIME
Press >) to change
The power down time is adjusted according to">"
and the power down time increases from 3 to 20
minutes (3-5-10-15-20), which is the so-called
stop time of the fan after shutdown, in order to
better drain the water.Factory set for 3 minutes.
(the other state of the fan is still 15 seconds.)
TEMP UNITS
Eu:
Press > to change
“Temp Units °F/°C”: Used for temperature scale
switching.Press the ">" button to switch °F / °С,
after switch symbol of corresponding parts is also
changing.
3.5.2
POWERING DOWN
System Shutdown
In 10:59
The screen displays when you press shut
down:
Indicates: the fan is closed after a few minutes,
and the standby page UNIT OFF is displayed after
the fan is closed.
MOISTURE CONTENT
UNITS
[+8] KG
Press > to change
“MOISTURE CONTENT UNITS”: Itis used to
switch the unit of GPP value with moisture
content. Press > to switch the LB or Kg, after
switch symbol of corresponding parts is also
changing.