Alorair Storm SLGR 850X Commercial Dehumidifier User Manual
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
8
Restoration & Moisture & Ventilation ALORAIR Sy, ' A AA a <Я Storm SLGR 850X Storm LGR 850X Storm LGR 850 Installation and Operations Manual READ AND SAVE THESE INSTRUCTIONS AlorAir Solutions INC. Add: 2048 E. Francis St Ontario CA 91761 Tel: 888-990-7469 E-mail: [email protected] DERUMDIFIER. Limited Warranty This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the original purchaser that this ALORAIR product is free from manufacturing defects in material or workmanship for the limited warranty period of: Six (6) Month parts and labor. This includes the shipments charges for replacement parts or unit. One (1) year parts and labor. This does not include the shipment charge to send the defective product back to be repaired or replaced. Three (3) years parts and labor on Refrigeration System ONLY (Compressor, Condenser, and evaporator). Transportation cost, not included. Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and evaporator). Transportation cost, not included. This limited warranty is valid only on products purchased from the manufacturer or ALORAIR authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Alorair Solutions Inc will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service. To receive warranty service, the purchaser must contact ALORAIR at 888-990-7469 or [email protected]. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of ALORAIR. Limited Warranty Exclusions This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following: e Damage occurs in uses for which this product was not intended for. e Damage caused by unauthorized modification or alteration of the product. + Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes. e Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature. + Damage caused by incorrect electrical line current, voltage, fluctuations, and surges. e Damage caused by failure to perform proper maintenance of the product. The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty. DERUMIDIFIER. Table of Contents Safety Instructions Identification Electrical Supply How the Dehumidifier Works Guidelines Parts Diagram Using the Display- Main Screen Maintenance Instructions Troubleshooting Warranty 10 11 DEHUMIDIFIER Safety Instructions e Don’t adjust or alter the unit in any way. ¢ The use of unauthorized parts will void your warranty. Contact your approved distributor for assistance. e Always unplug the unit prior to removing the cover. e Inspect the power cord prior to use and do not use if it is damaged. * The unit should only be used with a 115V/60Hz circuit protected by a GFCI outlet. Identification Prior to installation of the unit,write down the serial number and date of purchase. You will need this information if you need assistance in the future. The data label on the side of your unit has the necessary information. Model Number: Storm SLGR 850X[_] Storm LGR 850X[_] Storm LGR 850 | Serial Number: Date of Purchase: For additional questions concerning your dehumidifier: e Contact your installing contractor. e Contact AlorAir Solutions: [email protected] 888-990-7469 Electrical Supply Power Supply: 115V/60Hz Outlet Requirement: 3-Prong, GFCI Circuit protector:15 Amp WARNING: Using a 220V outlet may cause seriou s injury from electric shock. To reduce risk of injury: 1. Always disconnect machine from electrical power before servicing. 2. Only plug unit into a gounded electrical cicuit. 3. Do not use an extension cord. 4. Do not use a plug adapter. Symptom DEHUMIDIFIER Troubleshooting Cause Solution Display is Blank No Airflow Error Code: E1 Error Code: E4 Error Code: LO Error Code: HI E5 Error Code If the unit will be stored for an extended period of time, complete the following steps: 1. Turn off the unit and allow it to to dry. Poor Connection Power Outage Filter is Dirty Air Inlet or Outlet is Blocked Humidity Sensor or Communication Error Problem with Pump Room Temperature is below 33.8 F Room Temperature is above 110° F Refrigerant Leak Verify that both ends of the power cord are plugged in Reset power Clean the filter Clear the blockage Check to ensure that the sensor wire is connected at both ends. if no issues are visible, the sensor may be faulty. Verify that the pump is properly installed and functioning. If so, unplug the unit for two minutes, then restart. Increase the room temperatue so it is within operating range (above 33 8° F ). If error still displays, check sensor. Decrease the room temperatue so it is within operating range (below 110° F). If error still displays, check the sensor. Contact Your Installer for Assistance. Dehumidifier Storage 2. Clean out the pump reservoir. 3. Wrap and secure the power cord. 4. Cover filter mesh. 5. Store in clean, dry space. DEHUMIDIFIER Maintenance Instructions Before Use e Check the power cord for signs of damage such as fraying. Replace the cord before use if there is any damage. ¢ Check the filter for signs of dirt or obstructions. Clean or replace the filter as necessary. ¢ Check the coils for signs of buildup. Clean if needed. Cleaning the Machine Body Use a soft, damp cloth to clean the exterior of the unit. Do not use any soap or solvents. Filter Maintenance 1. Unplug the unit. 2. Slide out the filter. 3. Check the filter for dirt and buildup. 4. For a Pre-Filter or MERV-8: Clean the filter mesh by vacuuming it or washing with warm water (no soap or cleaners).Gently shake the filter dry, then reinsert it. 5. For a Carbon, or HEPA Filter: If there is dirt or buildup, replace filter. Removing the Housing 1. Remove the screws on the housing. 2. Remove the screws on the air inlet grill and air outlet grill. Coil Maintenance e Once per year, clean the coils with an approved coil cleaner. ¢ Coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil Cleaner. Pump Maintenance Pump Access: Remove the screws on the housing, then lift off. Unplug the pump drain line, then remove the screws holding the pump in place. Cleaning the Pump Reservoir: Once the screws are removed, lift off the top of the pump and set aside. Use a paper towel to wipe out the base of the pump. DERUMIDIFIER. How the Dehumidifier Works The dehumidifier utilizes its integral humidistat to monitor the conditioned space. Once conditions are outside the desired setpoint, the compresser energizes and air is drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air so the water vapor will turns into liquid condensation. The air is then reheated through the condenser coil and distributed back into the room. Guidelines Operation Notes + Always make sure that the unit is operated, transported, and stored on a stable surface. ¢ For maximum efficiency, operate the unit with all windows and doors closed. e Do not place the unit anywhere that may block the inlet or outlet airflow. Drain Hose Notes «e The Dehumidifier is equipped with an external drain line connection, making it easy to plug in. * The drain line can be directed outside or into any sink, drain, etc. * For more effective draining, uncoil the entire hose before using. * Never place the end of the hose higher than 15 feet. e Always ensure that the drain hose is not blocked prior to use. Transportation Notes e Always secure the dehumidifier during transportation enter period. ¢ If the unit is transported vertically, return it to a normal horizontal position, and let sit for 30 minutes prior to use. DEHUMIDIFIER DERUMIDIFIER. 6. Water Pump working interface display Compressor protection time not shown: Parts Diagram = ZA) 807 60% 93 PURGING SYSTEM A Important + Unplugging the unit without running the shutdown CTE Out =» u Set 000 JOBHRS 000 LIFEHRS sequence will allow water to remain in the unit after use. Staring 28 second | * Tilting the unit more than 70 degrees on the handle side or H and le more than 20 degrees on the non-handle side may result in water spillage. P u rg e Cycl e * Tilting wis unit without running the final purge may result in water spillage. Temp/RH Sensor “Pump working countdown”: Indicates: No matter in which working state and interface, as long as the pump works, this interface appears and counts down to 28 seconds.However, the interface only displays the previous working status and interface after 3 seconds.For example, after 3 seconds, there is a drainage icon on the main interface and it will flash until the drainage is finished. Easy Cord and Hose Storage Air Outlet 7. Interface display in case of failure Machine running time fault display: Wheel Make fault judgment and take corresponding actions after starting up. Regardless of the state, the fault is executed first and the fault = 1 LO H | code is displayed on the interface. If there is a fault in the sub-menu operation, immediately return to this interface display fault (including defrosting state). (the fault is judged when the pump = 5 E4 works, and the fault is displayed as usual, but the pump needs to complete the water pumping this time). Multiple faults can be displayed at the same time. Control Panel Description of fault display: Air Inlet % Humidity sensor fault: when the humidity sensor unit fault or signal can not be transmitted, the fault is judged to be E1. The machine is out of operation (power on again after troubleshooting). Pump button can operate. LUIS + LR % Ambient temperature T<2: When the sensor continuously detects the ambient temperature of inlet air T=2 degrees for 600 seconds, the fault is judged to be LO and the whole machine is stopped. Other values, Air Filter corresponding to the temperature region operation. (recoverable). At this time, the interface cannot be operated. The pump button can be operated. 2 @ Ambient temperature T>45: When the sensor continuously detects the inlet air environment Condensate Drain temperature T=45 degrees for 15 seconds, the fault is judged to be HI and the whole machine is stopped. Line Quick Connect Other values, corresponding to the temperature region operation. (recoverable). At this time, the interface cannot be operated. The pump button can be operated. DEHUMIDIFIER DEHLUMIDIFIER * LCD Display Instructions * "Humidistat Setpoint 00%":Used for setting dehumidification mode humidity.Press ">" to set the humidity. The adjustment SETPOINT | range of humidity setting is between 25 and 80%. Each key rises or falls 5%, which can be recycled. Press У» to change When the setting is completed,do not operate for 5 seconds and begin to take effect.(Otherwise, the compressor will be shut down immediately after it is below ambient humidity at “CO” indicates continuous mode the time of setting.) Humidity below 25 percents "CO" mode recyclable.The main interface displays the set parameters. 4. Main interface frosting status display: A RS The machine will display this after defrost when running PE | | scans 1. When the machine is powered on but not working: Zee} 80° 60% 93» (after power on, the buzzer makes a sound) —ALORAIR = DEFROSTING Defros Shutdown 8 0" 6 0 % 9 3 o/b In 06:00 Set 000 JOB HRS 000 LIFE HRS UNITOFF When the machine is running normally, “Deffrost When the user is operating in the submenu, the | SHUTDOWN IN 06:00” will occurs in the machine is in the frosting state.At this point, the Press ©) to start interface after defrosting. It's defrost countdown frosting interface displays 3 seconds, and returns www.alorair.com use seconds as units. This screen displays only to the submenu program in the background 3 seconds. Displays the previous interface and countdown.When the user returns to the main Boot display: The LOGO interface The machine displays when it is not status after restoration.If it is the home screen, interface without any operation, the frosting state la: og: . ae . will disappear after 2 seconds. Enter working. (Power off state but have the frost icon will flash. is displayed inthe main interface in the way of Bu nu icon flicker. the following interface. electricity) 2. Main interface display of dehumidification state: The following information is displayed when the machine is working: 000 JOB HRS: Refers to the working time, which is defined as the time from 5. Compressor on waiting interface display Compressor protection time not shown: “Compressor ready IN 03:00” indicates : That the starting up to shutting down, including the defrost time during Ze) 80° RESTARTING interface will be displayed when the compression is the period, and the standby time after the humidity. The x Compressor ready in a protected state. (including power-on and shutdown, b h + functi lf not. th kina ti hall (A= sor the humidity rises immediately after the arrival of LO submenu паз а reset tUncuon. и not, ле working time sia Où MD OIIMA HI, and the shutdown resu ediately after the be accumulated. Set In 03 00 emergence of LO HI).Displays the countdown in seconds.Ifthe Total time 9999 hours, the largest cumulative to the largest IES TR above situation does not occur within 3 minutes, it is not automatically reset after restart, and display units for hours. ie | (round off). shown. DEHUMDIFIER DERUNDIFIER e 000 LIFE HRS: Refers to the total working time, i.e. the total working time (hours), which is in hours.(press the mode key + select the confirmation key, and the total working time will be cleaned after 3 seconds. 3.4 ¢ IN/OUT 00°F 00% 00 gr/ Ib: Indicates the temperature, humidity and moisture content of the air inlet and outlet WIFI HOTSPOT {GPP - grain per pound (gr/Ib)}. ‚ Set 00%: Off Indicates set humidity. WI-FI hotspot: Factory setting is "OFF", press > to enable wifi hotspot and switch ON/OFF.The device can transmit data and receive APP commands.The icon flickers when connected on the main interface. After successful connection, the icon displays normally. « If the main interface does not operate for 10 minutes, the screen will go out.Press any key to wake up. e Other icons light up or flicker when opened. The total working time is the accumulation of each working time (hours) in hours. (Press the mode key + select to confirmation key, and the total working time will be cleaned after 3 seconds. 3.Dehumidification status submenu interface display NAME 3.1 Alorair Dehumidifier Go to the app to change Device name displayed on the screen: You can change the device name on the APP application. JOB HOURS “Indicates”:Do | need to clear out this time?", press ">"if you need to clear. When the operation 3.2 9999 interface and the working time of this interface will be reset and started to be instant again. is completed, the working time of the main Hold > to Reset After accumulation (9999), clean up and round. COILTEMP “Coil Temp 000°C ”: Used to display the current 3.3 temperature of the coil. When it is below zero, " = the "-" symbol is displayed in front. "-" is not required on zero. Press >> to change 3.5.1 POWER DOWN TIME Press >) to change The power down time is adjusted according to">" and the power down time increases from 3 to 20 minutes (3-5-10-15-20), which is the so-called stop time of the fan after shutdown, in order to better drain the water.Factory set for 3 minutes. (the other state of the fan is still 15 seconds.) TEMP UNITS Eu: Press > to change “Temp Units °F/°C”: Used for temperature scale switching.Press the ">" button to switch °F / °С, after switch symbol of corresponding parts is also changing. 3.5.2 POWERING DOWN System Shutdown In 10:59 The screen displays when you press shut down: Indicates: the fan is closed after a few minutes, and the standby page UNIT OFF is displayed after the fan is closed. MOISTURE CONTENT UNITS [+8] KG Press > to change “MOISTURE CONTENT UNITS”: Itis used to switch the unit of GPP value with moisture content. Press > to switch the LB or Kg, after switch symbol of corresponding parts is also changing.
advertisement