330-995-9642 INSTALLATION AND SERVICE MANUAL


Add to my manuals
35 Pages

advertisement

330-995-9642 INSTALLATION AND SERVICE MANUAL | Manualzz

330-995-9642

COMBINED ANT COMBINED LOAD

ANT

LOCAL MODE

TX 1 SW 1

SEPARATE TX 1 SEPARATE TX 2

PLATES ON

SW 3

COMBINER

REJECT

LOAD

POWER

PLATES OFF

TX 2 SW 2 TX 3

DUMMY

LOAD

TRC-3

TRC-3

FM SWITCH CONTROLLER

FOR 3 COAX SWITCHES AND COMBINER

AUTO

INSTALLATION AND SERVICE MANUAL

Rev Sept 2007

TRC-3 3-Switch FM controller–general ----------------------2

PLC (programmable logic controller) -----------------------2

CONNECTIONS -----------------------------------------------3

Coax switch connections -----------------------------------3

Remote control connections --------------------------------4

Coax switch reverse jumpers -------------------------------4

Transmitter interlock connections -------------------------5

Transmitter 2 analog/digital connections ------------------5

Dummy load connection -------------------------------------6

Plates on/off connections ---------------------------------6

Auto transfer connections ---------------------------------7

Optional connections --------------------------------------7

Reject load interlock connection --------------------------8

OPERATION -------------------------------------------------8

Antenna system modes --------------------------------------9

Illuminated pushbuttons -----------------------------------9

Plates on/off ---------------------------------------------9

Auto transfer key switch ----------------------------------9

Remote control commands ----------------------------------10

Local key switch -----------------------------------------10

Fuses ----------------------------------------------------10

Command polarity -----------------------------------------10

Controller schematic diagram -----------------------------11

Interconnection chart ------------------------------------12

Coax switch wiring charts --------------------------------13

Front panel indicator combinations -----------------------14

Logic tables ---------------------------------------------15

Component layout -----------------------------------------16

Dielectric 50000 series switch manual -------------------1-7

Dielectric 60000 series switch manual ------------------1-10

Appendix A “FM Control system Principles” -----------3 pages

IF THE CONTROLLER WILL NOT ALLOW TRANSMITTERS TO RUN IN

COMBINED MODES, CHECK THAT THE REJECT LOAD INTERLOCK (TB6,

PINS 1 AND 4) HAS A JUMPER OR IS CONNECTED TO THE LOAD.

IF THE CONTROLLER WON’T MOVE THE COAX SWITCHES, CHECK THAT

THE TRANSMITTER OFF TALLIES (TB6, PINS 5 AND 9 TO PIN 1) HAVE

JUMPERS OR ARE CONNECTED TO THE TRANSMITTERS.

TRC-3 3-SWITCH FM CONTROLLER

This is a controller for three coaxial switches, two or three transmitters, one antenna, combiner, and a dummy load. It was designed for Dielectric 50000 and 60000 series coax switches but will also work with others. All connections are either made to barrier strip terminals or 9-pin

AMP connectors on the back panel.

The controller has no memory of what the coax switch positions were the last time it was on. It will not move coax switches when powered on. If the coax switches are in a valid combination of positions, the controller will enable the appropriate transmitter interlocks. If any coax switches are between positions when the controller is powered on, it will not do anything, but any local or remote command will move all switches to the correct positions.

PLC (PROGRAMMABLE LOGIC CONTROLLER)

This is a PLC-based controller. All functions are controlled by a NAIS FP0-C14RS programmable logic controller, with 3 FP0-C16RS expansion modules. Programmable logic controllers are not well known to broadcast engineers but have been widely used in the manufacturing industry for decades. The FP0 is a microprocessor controller, built into a convenient package that includes input isocouplers, output relays, status indicators, terminals and connectors, and a programming interface. PLC’s are designed and constructed to survive and perform in the environments found in industrial facilities, which typically present several challenges to electronic equipment; heat, dust, vibration, magnetic fields, and power line transients.

No knowledge of PLC programming is needed to install and use the controller. The PLC uses

EEP-ROM for program memory. No backup battery is required, so program loss should not be a concern, even if the controller is unplugged for months or years.

The PLC and expansion unit in this controller have opto-isolated electronic logic inputs, and relay contact outputs. All controller inputs are configured for contact closure equipment (such as a Burk ARC-16 remote control with IP-8 relay panels).

COAX SWITCHES AND CONTROLLERS

If you’re not familiar with FM control systems, or coax switches and their control and status signals, Appendix A “FM Transmitter Control Systems General Terms and Principles” may be of interest.

Tunwall Radio LLC 1312 Suffield Oaks Lane Suffield, OH 44260 [email protected] 330-995-9642

2

CONNECTIONS

Barrier strip terminals are provided for transmitter and remote control connections All barrier strip terminals are max 24VDC.

Coax switch connections are made to 9-pin AMP connectors, which use the same pins as

Dielectric 60000 switch connectors. The 9-pin connectors can be installed with several types of pin crimpers commonly used in studio console projects. One suitable tool is Paladin 1645,

Newark part #97B3917. Pin 8 of the AMP connector is 120VAC “hot” and pin 9 is AC neutral, used for the motors in 50000 switches. 60000 switches get AC power from a separate power cord.

A wiring chart is provided for convenience of installation. If non-Dielectric switches are to be used, connections from representative switch manuals are shown on the coax switch connection chart following the schematic diagram and interconnections pages. Wiring variations in non-Dielectric coax switches, even of the same model number, have been found. Some have internal control relays or not, some have 120V neon indicators or not, and any connections may be different. If the original documentation for your switch is not available, the internal connections should be verified before connection to the controller.

Power for the controller can be connected to a UPS, at the engineer’s discretion. The PLC is powered by a switching DC supply that does not usually require protection from transients, or high line voltage – it is designed to operate from up to 250 volts AC. The need for lightning protection is a local decision. The auto transfer function includes a 5 minute power-on delay, to avoid unwanted transfers due to power interruptions. The power-on delay would not work if the controller is powered by a UPS.

COAX SWITCH CONNECTIONS – POSITION TALLY CLOSURES

The controller needs to know what position the coax switches are in. Pins 1-4 of AMP connectors

P1 to P3 are for the coax switch tallies. Each coax switch cable is identical, and combinations of switch positions are handled by coax switch reverse jumpers, described in the jumper section below.

COAX SWITCH CONNECTIONS - MOTOR CONTROL RELAYS

The controller is compatible with coax switches that have 120VAC, 12VDC or 24VDC motor control inputs/relays. Position change commands are on pins 5-7 of AMP connectors P1 to P3.

With 120VAC motor control relays in a 50000 switch, no connection is needed to pin 6. Two internal jumpers on the interconnection board change the command output wiring between

12VCD, 24VDC and 120VAC.

For 120VAC relays in 50000 switches only – the Dielectric switch schematic does not exactly match the TR controller diagram. The controller reverses AC line and neutral connections, so that neutral is switched through the controller’s output terminals instead of line. This way, if the controller’s internal voltage select switches are set to 120VAC by mistake, DC relay coils or inputs will not be destroyed. The AC motor in the 50000 switch does not know the difference. 7/8” 50000 switches have DC motors but since they are powered by AC through a transformer and rectifier circuit, this should not matter.

Tunwall Radio LLC 1312 Suffield Oaks Lane Suffield, OH 44260 [email protected] 330-995-9642

3

Solenoid-type switches might be compatible with the controller but they are generally considered inferior to motorized types, so no consideration for solenoid switches was given to the controller design.

Some Dielectric 50000 switches were shipped with 110VDC relays. These will not work with the controller. In this case you would need to get 12 or 24VDC (or 120VAC) relays, either from

Dielectric or from a parts supplier. A (very) few switches may have a 240–120V step-down transformer, which would have to be removed to use the controller.

The schematic diagram page indicates the 50000 switch terminal letters, in blue. The interconnection page shows connections for the 60000 switch. The coax switch connection chart following these two pages shows connections for several other coax switches.

REMOTE COMMAND CONNECTION

Controller terminals TB1-6 to TB1-10 and TB2-1 to TB2-3 are the remote position select and remote plates on/off connections. Floating relay contacts are best, such as the Burk IP-8, but open collector equipment may be used if it is compatible with positive common wiring.

REMOTE STATUS CONNECTION

The remote control status outputs are connected through diodes to the front panel illuminated pushbuttons. Even though there are multiple PLC expansion modules in the controller, there are a limited number of outputs, not enough for separate local and remote status circuits. The diodes keep the front panel illuminated pushbutton indicators from lighting through the remote control’s pull-up resistors. This status circuit has been used in hundreds of controllers so far, without any reports of a problem.

The remote control status outputs are compatible with most remote control systems, Burk as an example. The Burk ARC-16 documentation states that the status inputs can be connected to circuits up to 28 VDC. The only requirement is that one state of the circuit be ground, or near ground. The PLC output relays cause terminals TB1-2 to TB1-5 (TB1-1 common) to go near ground when a remote status indication is on.

The remote status outputs follow the 4 system modes; Combined Antenna, Combined Load, etc., not the switch position indicators in the front panel flow chart.

COAX SWITCH REVERSE JUMPERS

Coaxial switch ports are usually connected to transmitters, antennas, and load according to the physical layout of the equipment and building, rather than arbitrary port number assignments. This can result in different combinations of switch positions for the 4 antenna system modes

(Combined Antenna, etc). Rather than wiring switch cables backward when their ports don’t match a fixed controller design, the controller can reverse the front panel indicators, transmitter interlock logic, plate on/off logic, and switch position commands by connecting jumpers on the controller back panel.

“Normal” (no reverse jumpers needed) is when all 3 coax switches are in their position 1 when the antenna system is in Combined Antenna mode. If any or all of the coax switches are in their position 2 for Combined Antenna mode, connect a corresponding jumper(s) to the appropriate terminals on TB2 terminals 6-10. Refer to the schematic diagram page on the left side to determine which of these jumpers are needed. TB2-6 and TB2-7 are both +24V common.

Tunwall Radio LLC 1312 Suffield Oaks Lane Suffield, OH 44260 [email protected] 330-995-9642

4

The 4 antenna system modes are:

Combined Antenna

Combined Load

Separate TX 1

Separate TX 2

Each of these modes mean two things. The 4 front panel indications (illuminated pushbuttons) and remote status closures could be labeled:

Combined Antenna, TX 3 on Load

Combined Load, TX 3 on Antenna

Separate TX 1 on Antenna, TX 2 on Load

Separate TX 2 on Antenna, TX 1 on Load

…but room on the front panel for labeling is limited. The antenna system mode needed for load testing and TX 3 on antenna can be easily seen with the front panel graphic display.

It doesn’t matter if your system has a third transmitter or not. If #3 is added later, the logic and control is programmed into the controller.

The 3 coax switches have 8 position combinations (for any combination of reverse jumpers or none) but only 4 are used or valid. The 4 valid switch position combinations allow all transmitters to get where they need to go, so there are 4 switch combinations that are ignored, as shown on the logic table page. If the switches are manually moved to one of the ignored switch combinations, the controller will not allow any transmitter to run. A valid antenna system mode can be restored with any local or remote command, no matter what positions the switches have been moved to.

TRANSMITTER INTERLOCK CONNECTIONS

The controller’s interlock terminals are to be connected to the interlock or mute terminals of the transmitters. Older transmitters may not have terminals designated for this purpose, but may have connections for remote plate off. If such a circuit operates with a continuous closure that holds the plate on, the controller’s interlock terminals may be wired in series with this circuit. The PLC’s transmitter interlock outputs are floating relay contacts. The transmitter interlock outputs are normally close-to-run, but jumpers on TB6 can reverse the interlock logic (to open-to-run) for each transmitter individually.

Transmitter interlock and plate on/off terminal numbers are shown on the Interconnection page, following the schematic diagram.

The PLC relay contacts are rated for 220 VAC. It is up to the engineer’s judgment whether to bring high voltage control circuits out of older transmitters. Since the transmitter control connections are barrier strips, low voltage is better if possible.

TRANSMITTER 2 ANALOG / DIGITAL CONTROL CONNECTION

Whenever the system is in Separate TX 2 mode, the analog/digital control relay is energized, and terminals TB5-3 (com) and TB5-1 (analog) will be closed. Analog may mean a composite digitaland-analog transmitter mode. When the system is not in Separate TX 2 mode, the relay is not

Tunwall Radio LLC 1312 Suffield Oaks Lane Suffield, OH 44260 [email protected] 330-995-9642

5

energized, and terminals TB5-3 (com) and TB5-2 (digital) will be closed. Although the TX 2 control board may be intended to operate from momentary closures, most transmitter control circuits will work properly with continuous interface closures, and not be damaged. For a function like analog/digital, it is usually best to use continuous closures, to lock the function to the antenna system’s operational mode. If the continuous closures are determined to be a problem, an external conversion to a momentary signal will have to be devised.

DUMMY LOAD CONNECTION

The tally terminals of your dummy load should be connected to controller terminals TB2-4 and TB2-5.

The PLC has been programmed to operate correctly with a dummy load contact closure when the blower or water is “on”. This allows the transmitter not on-air to be energized, for testing on the load.

When the load is off, the transmitter(s) switched to it will be muted. Filament and blowers should be able to operate, with most transmitters.

If the station’s load in a convection type, a switch should be installed in the rack and labeled “Load

Interlock”. This way the off-air transmitter(s) will normally not be allowed to run when no one is at the transmitter site, but it is easy to use the switch to allow load testing.

A “Load Interlock” switch in series with the load tally contacts might be desirable for Altronic fan loads, due to the nature of their tally contact operation. Altronic tally contacts close any time the load is connected to power. Altronic loads turn on their fans when the load heats up, which protects the load resistors, but the unwanted heat that might result from an accidental plate on command to an off-air transmitter might be a problem for some transmitter buildings. As an alternative, some engineers unplug their Altronic loads when finished with load testing.

The controller is able to switch positions when the load interlock is active, but the coax switch is still protected from “hot” switching – the transmitters will be muted.

There is a front panel load ready indicator, in the flow chart graphic.

PLATE ON / OFF CONNECTIONS

“Plate” is traditional; RF on/off or similar is becoming more common. These are floating relay contacts, which should work with any transmitter.

There are no separate filament on/off terminals. For most tube transmitters, a cold plate on is not a problem. If the transmitter’s internal control circuits are working correctly, the plate supply will not be turned on until the filament delay runs out.

The plate off terminals might be connected to the filament off terminals of a tube transmitter, if you want the filament and blower to shut down when the transmitter is switched off-air. If the transmitter’s internal control circuits are working correctly, the plate will turn off immediately, and the filament time-out will cycle before the blower is turned off. A possible disadvantage to connecting plate off to the filament off circuit is that a transfer from Combined Antenna to a separate mode might cause a filament warm-up delay before getting back on-air.

If all of the plate on and plate off closures are connected to your transmitters, the system may be more automatic than you would like. If you don’t plan to use AUTO transfer, you may not want to connect any of the plate control closures. Or, connect just the closures you want. Terminals for plate on/off control are shown on the schematic and interconnection pages.

Tunwall Radio LLC 1312 Suffield Oaks Lane Suffield, OH 44260 [email protected] 330-995-9642

6

AUTO TRANSFER CONNECTIONS

This is an optional function, selected by a front panel key switch, to transfer to a separate transmitter if a combined transmitter fails. Details on the auto transfer sequence are explained in the OPERATION section.

Connections related to auto transfer are made to TB3-7 to TB3-10 and TB4-7 to TB4-10. With auto transfer on, to tell the controller that TX 1 and TX 2 are working, a fail signal for each transmitter must be provided:

A continuous closure from floating contacts, maintained when the transmitter is running, or

Continuous 5 volts DC when the transmitter is running, which is not connected to ground by the controller

The 5 volt option energizes a small single pole relay, whose NO contacts are connected in parallel with the controller’s transmitter fail closure inputs. The current draw of the 5 volt relay is

38ma. The 5 volt relay coils have “protection” diodes, so polarity matters, and is indicated on the schematic drawing and interconnection chart. One transmitter (or RF detector, etc.) can provide a closure and the other can use 5 volts, whichever is available. If a transmitter’s fail closure opens, or if the 5 volt signal drops, the controller will switch the other to the antenna. If both transmitters’ on signals drop at the same time, the controller won’t do anything.

The closure or 5 volts can come from the transmitter or any other device such as a Bird Wattcher or suitable modulation monitor.

If you only want one transmitter transfer to be allowed, e.g. only TX 1 can be on the antenna by itself, then jumper the TX 2 fail terminals, so it can never “fail”.

TRANSMITTER OFF TALLIES

The controller can be configured so that coax switches will not be moved without “off” closures from transmitters 1 and 2. Most transmitters would require modification or the addition of a relay or equivalent device. If transmitter off tallies are not used, jumper connections are required between

TB6-1 (common) and TB6-4 and TB6-5 or the coax switches will not move. There is no off tally connection for transmitter 3.

REMOTE MUTE ALL CONNECTION

TB6-2 (TB6-1 common) is an optional connection for a closure to mute all transmitters at any time.

REMOTE AUTO KILL CONNECTION

Described in more detail in the AUTO transfer operation section. TB6-3 (TB6-1 common) is an optional connection to get out of Separate TX 1 or 2 after a transmitter failure and automatic transfer, by remote control.

Tunwall Radio LLC 1312 Suffield Oaks Lane Suffield, OH 44260 [email protected] 330-995-9642

7

REJECT LOAD INTERLOCK CONNECTION

If the reject load has an overheat tally contact that opens on overheat, it can be connected between TB6-1 (common) and TB6-9, to shut down transmitters 1 and 2 in combined modes. The reject load interlock has no effect in separate modes. There is no timeout; transmitter interlocks will close immediately when the reject load interlock is restored. If the reject load interlock is not used, a jumper is required between TB6-1 (common) and TB6-9, or transmitters 1 and 2 will not run in combined modes.

OPERATION

From a single local or remote command, the controller operates the transmitter interlocks and switch motors in a timed sequence such that the switches are never moved with RF power applied. The transmitters are “interlocked” or muted, before the switch motors are energized.

Other functions include optional automatic transmitter transfer in case of failure, plate on and off control, and transmitter load testing.

ANTENNA SYSTEM MODES

The first 4 front panel pushbuttons are the local controls for:

Combined Antenna

Combined Load

Separate TX 1

Separate TX 2

Pushing any of these buttons will lock out the other 3 for the duration of the switching sequence.

The switching sequence is: transmitter interlock connections open and plates off; a short delay to let the transmitters’ plate supplies discharge; coax switch operation (as long as it takes up to 30 seconds); at completion of switch movement, interlock on delay, 0.2 second (to let the coax switch settle mechanically, in case the coax switch tally signal is slightly ahead of the absolute end of travel); and transmitter interlock(s) on.

The controller has terminals for remote position change commands. These work exactly as the front panel pushbuttons unless the controller is in local. In local, only the front panel pushbuttons are active.

After a switch sequence has been started, if the coax switch “hangs”, the transmitter interlocks will not be closed. This is the primary purpose of the controller, of course; preventing the coax switches from being moved under power. If a switch hangs during a transfer and is then manually moved to either position, the controller will enable the interlock(s) for the correct transmitter(s) if the combination of switch positions is valid.

This controller is programmed to reset itself after 30 seconds, if a coax switch hangs. After the 30 second time-out, you can try the position change again, or return to the previous position. If the front panel pushbutton for the antenna system mode presently in use is pushed, nothing will happen.

If a coaxial switch is moved manually, the transmitter interlocks will open. This doesn’t make it safe or a good idea to move a switch manually under power. If a switch is moved manually, when it “makes” either position, there will be a 0.2 second delay before the transmitter interlocks are restored, if the switch position combination is valid.

Tunwall Radio LLC 1312 Suffield Oaks Lane Suffield, OH 44260 [email protected] 330-995-9642

8

ILLUMINATED PUSHBUTTONS

The first 4 pushbuttons are illuminated, and show the antenna system mode in use:

Combined Antenna

Combined Load

Separate TX 1

Separate TX 2

Only one of these indicators will be on at a given time. During a transfer sequence, the status indicator for the selected mode will flash. The remote control status outputs flash along with the illuminated pushbuttons. If a coax switch hangs between positions, the controller will reset after

30 seconds, and none of these 4 indicators will be on. After the reset, the failed mode can be selected again, or any of the others. All front panel indicators are solid-state.

PLATE ON/OFF

If all plate on and off terminals are connected, the control system is fully automatic – for any antenna system command, the transmitter plates will all be turned off, and at the end of the switching sequence, the appropriate transmitters will be turned on. The AUTO key switch has no effect on the plate on/off command outputs.

In local, plate on/off are front panel-only functions, but plates are still all turned off automatically by any change sequence. You can connect the plate on or off commands you want to use, or none at all. The plates on and plates off pushbuttons will turn plates on and off for the transmitters active in any of the antenna system modes; e.g. in Combined Antenna, TX 1 and

TX 2 will be turned on and off. If the load is running in combined modes, all 3 transmitters will be turned on. There are remote control terminals for Plates on/off.

AUTO TRANSFER KEY SWITCH

This is a key switch selected option that is only active in Combined Antenna, and it only applies to transmitters 1 and 2. The key switch illuminates the indicator, so although auto transfer is inactive in other antenna system modes, the indicator is on whenever the key switch is in the right position. The AUTO option does not work in local. There are two rear panel indicators, TX

1 and TX 2, that can be verified before turning the AUTO key switch. Auto transfer is not active for 5 minutes after power-on, to help avoid unwanted transfers due to power interruptions.

When in Combined Antenna, turn the AUTO key switch to the right to engage automatic transfer. TX 1 and TX 2 transmitter “on” signals have been connected to the transmitter fail closure terminals, according to the AUTO TRANSFER CONNECTIONS section. If either transmitter’s on signal fails for 5 seconds, the controller will switch to the separate mode for the other transmitter. The sequence is the same as if a front panel transmitter change button was used, except that the separate mode’s front panel pushbutton light and remote control output will keep flashing. If both transmitters fail at the same time, the controller won’t do anything.

The TX 2 analog/digital relay switches to analog whenever Separate TX 2 mode is active, whether it was selected manually or automatically.

Following an auto transfer, none of the local or remote mode change commands will do anything until auto transfer has been reset. Auto transfer can be reset by turning the key switch

Tunwall Radio LLC 1312 Suffield Oaks Lane Suffield, OH 44260 [email protected] 330-995-9642

9

off. Auto transfer can also be reset by remote control. Terminals for this are covered in the auto transfer connections section. If auto transfer is reset by remote control, the flashing indicator and corresponding remote control output will stop flashing, and the mode change commands are ready. If a mode other than Combined Antenna is selected next, the auto transfer key switch is ignored.

If, after an auto transfer and remote reset, Combined Antenna is selected, you have 60 seconds after the change, plus the 5 seconds failure time, to get both TX 1 and TX 2 running or the controller will transfer to a separate mode again. The 60 seconds does not start until you switch to Combined Antenna mode.

REMOTE CONTROL COMMANDS

Terminals for 6 remote control command inputs are provided, that duplicate the functions of the

6 front panel position pushbutton switches, except when the local key switch is activated. The front panel pushbuttons operate in local.

LOCAL KEY SWITCH

The local key switch can be used to lock out remote control commands. The front panel pushbuttons operate in local.

The LOCAL and AUTO switches use the same key, which can be removed from either switch in either position.

FUSES

The front panel DC fuse is on the output of the 24V power supply. 1A should be a good value for this. The AC fuse is in series with the “hot” lead for the entire controller, and the AC power for

Dielectric 50000 series coax switches. If no coax switches are powered by the controller, the AC fuse can be about 1A. If 50000 coax switches are used, the AC fuse should be about 3A per switch, since all coax switches will move simultaneously sometimes. Although the AC fuse holder may be labeled 3A, larger or slow-blow fuses can be used at the engineer’s judgment. The internal AC wiring is 18ga, good for at least 10A. The 50000 switch specifications state that the motor inrush current is 3.5A, and the running current is 0.5A.

COMMAND POLARITY

The header plug labeled “polarity” on the interconnect board is to reverse DC polarity for

Andrew/ERI coax switches. The Dielectric configuration shown on the schematic diagram is used for any switch other than Andrew/ERI, as of the time this manual was assembled.

Tunwall Radio LLC 1312 Suffield Oaks Lane Suffield, OH 44260 [email protected] 330-995-9642

10

INPUT AND OUTPUT

CONNECTIONS MARKED

WITH LETTERS ARE TO

DIELECTRIC 50000 SWITCH.

FOR 60000 OR OTHER

SWITCHES, SEE THE

CONNECTIONS PAGE.

TRC-3

3-SWITCH TRANSMITTER AND COAXIAL

SWITCH CONTROLLER

COAX SWITCH 1

POSITION

INDICATOR

CONTACTS

COAX SWITCH 2

POSITION

INDICATOR

CONTACTS

COAX SWITCH 3

POSITION

INDICATOR

CONTACTS

M

L

R

R

S

M

L

R

S

S

M

L

P3-2

P3-3

P3-4

P2-2

P2-3

P2-4

P3-1

P1-1

P1-2

P1-3

P1-4

P2-1

SW 1 POS 1 TALLY

SW 1 POS 2 TALLY

SW 2 POS 1 TALLY

SW 2 POS 2 TALLY

SW 3 POS 1 TALLY

SW 3 POS 2 TALLY

REMOTE

CONTROL

RMT CMD COM

TB2-1

TB1-6

TB1-7

TB1-8

TB1-9

TB1-10

TB2-2

TB2-3

T6-2

T6-3

T6-1

FRONT PANEL

PUSHBUTTONS

NC

FP

SWITCH

SWITCH REVERSE COM

COAX SWITCH

POSITION REVERSE

JUMPERS

TRANSMITTER

INTERLOCK REVERSE

JUMPERS

TB6-1 COM

TB2-6/7

TB2-8

TB2-9

TB2-10

TB6-6

TB6-7

TB6-8

COMBINED ANT

COMBINED LOAD

SEPARATE TX 1

SEPARATE TX 2

PLATES ON

PLATE S OFF

MUTE ALL

RMT AUTO KILL

SWITCH 3 REVERSE

SWITCH 2 REVERSE

SWITCH 1 REVERSE

INTERLOCK 1 REVERSE

INTERLOCK 2 REVERSE

INTERLOCK 3 REVERSE

AROMAT BASE

1 INPUT COM

2 INPUT 0

3 INPUT 1

4 INPUT 2

OUTPUT COM 0 34

OUTPUT 0 35

OUTPUT 1

36

OUTPUT 2 37

OUTPUT 3 38

5 INPUT 3

6 INPUT 4

7 INPUT 5

INPUTS 6 AND

7 NOT USED

OUTPUT COM 1 39

OUTPUT 4 40

OUTPUT COM 2 41

OUTPUT 5 42

AROMAT EXPANSION 1

8 INPUT COM

9 INPUT 20

10 INPUT 21

11 INPUT 22

12 INPUT 23

13 INPUT 24

14 INPUT 25

OUTPUT COM 43

OUTPUT 20

44

OUTPUT 21 45

OUTPUT 22 46

OUTPUT 23 47

OUTPUT 24 48

OUTPUT 25 49

15 INPUT 26

16 INPUT 27

OUTPUTS 26

AND 27 NOT

USED

AROMAT EXPANSION 2

17 INPUT COM

18 INPUT 40

19 INPUT 41

20 INPUT 42

21 INPUT 43

22 INPUT 44

23 INPUT 45

OUTPUT COM 50

OUTPUT 40 51

OUTPUT 41 52

OUTPUT 42 53

OUTPUT 43 54

OUTPUT 44 55

I/O 46 AND 47

NOT USED

OUTPUT 45 56

ILLUMINATED

PUSHBUTTONS

COMBINED ANT

COMBINED LOAD

SEPARATE TX 1

SEPARATE TX 2

STATUS COM

COMBINED ANT STATUS

COMBINED LOAD STATUS

SEPARATE TX 1 STATUS

SEPARATE TX 2 STATUS

INTERLOCK TX 1

INTERLOCK TX 1

INTERLOCK TX 2

INTERLOCK TX 2

S1 P1

S1 P2

S2 P1

S2 P2

S3 P1

S3 P2

COAX SWITCH STATUS

INDICATORS

EACH INDICATOR

SHOWN IS ACTUALLY

TWO

TB1-1

TB1-2

TB1-3

TB1-4

TB1-5

TB3-1

TB3-2

TB4-1

TB4-2

LOAD

INTLK

TB2-4

TB2-5

FP

SWITCH

LOCAL MODE

LOAD INTLK

TRANSMITTER

FAIL CLOSURE

MAINTAINED

FOR TX ON

TB3-7

TRANSMITTER

FAIL RELAY COIL

5V

TB3-10

TB4-7

TRANSMITTER

FAIL CLOSURE

MAINTAINED

FOR TX ON

TB4-8

TB4-9

TRANSMITTER

FAIL RELAY COIL

5V

TB3-8

TB3-9

TB4-10

T6-4

T6-5

T6-9

FP

SWITCH

TX 1 FAIL CLOSURE

5V

14

13

38 MA

MEASURED

@ 5V

K9

TX 2 FAIL CLOSURE

13

5V

14

K10

TX 1 OFF TALLY

TX 2 OFF TALLY

REJECT INTLK

AUTO MODE

TX 1 ON IND

BACK PANEL

TX 2 ON IND

BACK PANEL

AROMAT EXPANSION 3

24 INPUT COM

25 INPUT 60

OUTPUT COM 57

OUTPUT 60 58

26 INPUT 61

OUTPUT 61 59

27 INPUT 62

OUTPUT 62 60

28 INPUT 63

29 INPUT 64

30 INPUT 65

31 INPUT 66

33 INPUT 67

OUTPUT 63 61

OUTPUT 64 62

OUTPUT 65 63

OUTPUT 66 64

OUTPUT 67 65

+

24 VOLT

POWER SUPPLY

L N G -

K8

K7

K6

K1

K2

K3

K4

K5

POWER INDICATOR

GROUND

NEUTRAL

LINE

DRAWN BY

TUNWALL RADIO LLC

TRC-3 TRANSMITTER AND COAXIAL SWITCH CONTROLLER

SERIAL 3FM39+ Rev Sept 2007 SHEET 1 0F 2

S. TUNWALL

7812

POLARITY PLUG

24V

DIELECTRIC

ANDREW

D

C

N

C

N

D

C

N

D

P2-6

P2-7

P3-5

P3-6

P3-7

P1-5

P1-6

P1-7

P2-5

COAX SWITCH 1

RELAY

COILS

COAX SWITCH 2

RELAY

COILS

COAX SWITCH 3

RELAY

COILS

12V

DC

TX 3 PLATE OFF

TX 3 PLATE OFF

TX 3 PLATE ON

TX 3 PLATE ON

TX 3 INTERLOCK

TX 3 INTERLOCK

TX 2 DIGITAL / ANALOG COM

TX 2 DIGITAL MODE

TX 2 ANALOG MODE

120V

TX 1 PLATE ON

TX 1 PLATE ON

TX 1 PLATE OFF

TX 1 PLATE OFF

TX 2 PLATE ON

TX 2 PLATE ON

TX 2 PLATE OFF

TX 2 PLATE OFF

TB4-4

TB4-5

TB4-6

P1-8

P1-9

P2-8

P2-9

TB3-3

TB3-4

TB3-5

TB3-6

TB4-3

A

B

A

B

TB5-5

TB5-3

TB5-2

TB5-1

TB5-8

TB5-9

TB5-6

TB5-7

TB5-4

AC FUSE

P3-8

P3-9

A

B

POWER

CORD

CONTROLLER

PLUG 1

1

8

9

6

7

4

5

2

3

CONTROLLER

PLUG 2

1

8

9

6

7

4

5

2

3

CONTROLLER

PLUG 3

1

8

9

6

7

4

5

2

3

CONTROLLER

TB 1

1

4

5

2

3

8

9

6

7

10

SWITCH AND REMOTE CONTROL CONNECTIONS

POS 1 TALLY

POS 1 TALLY

POS 2 TALLY

POS 2 TALLY

POS 1 COMMAND

COMMAND COM

POS 2 COMMAND

FUSED 120 VAC

NEUTRAL

COAX SWITCH 1

50000

C

N

D

M

L

R

S

A

B

POS 1 TALLY

POS 1 TALLY

POS 2 TALLY

POS 2 TALLY

POS 1 COMMAND

COMMAND COM

POS 2 COMMAND

FUSED 120 VAC

NEUTRAL

COAX SWITCH 2

50000

C

N

D

M

L

R

S

A

B

POS 1 TALLY

POS 1 TALLY

POS 2 TALLY

POS 2 TALLY

POS 1 COMMAND

COMMAND COM

POS 2 COMMAND

FUSED 120 VAC

NEUTRAL

COAX SWITCH 3

50000

C

N

D

M

L

R

S

A

B

60000

DC

3

13

4

11

12

15

16

60000

DC

3

13

4

11

12

15

16

60000

DC

3

13

4

11

12

15

16

60000

AC

11

12

15

16

22

23

24

60000

AC

11

12

15

16

22

23

24

60000

AC

11

12

15

16

22

23

24

STATUS COM

STATUS CHx

COMBINED ANT

STATUS CHx

COMBINED LOAD

STATUS CHx

SEPARATE TX 1

STATUS CHx

SEPARATE TX 2

COMBINED ANT

COMBINED LOAD

REMOTE INPUT COM

R/L CHx

R/L CHx

R/L CHx

SEPARATE TX 1

R/L CHx

SEPARATE TX 2

GROUND

NEUTRAL

LINE

DRAWN BY

TUNWALL RADIO LLC

TRC-3 TRANSMITTER AND COAXIAL SWITCH CONTROLLER

SERIAL 3FM39+ Rev Dept 2007 SHEET 2 0F 2

S. TUNWALL

POWER

CORD

CONTROLLER

TB 4

1

8

9

6

7

10

4

5

2

3

CONTROLLER

TB 3

1

8

9

6

7

10

4

5

2

3

CONTROLLER

TB 2

1

6

7

4

5

2

3

8

9

10

PLATES ON

PLATES OFF

REMOTE INPUT COM

R/L CHx

R/L CHx

LOAD INTERLOCK

LOAD INTERLOCK

COAX SWITCH REVERSE COM

COAX SWITCH REVERSE COM

COAX SWITCH 3 REVERSE

COAX SWITCH 2 REVERSE

COAX SWITCH 1 REVERSE

TX 1 INTERLOCK

TX 1 INTERLOCK

TX 1 PLATE ON

TX 1 PLATE ON

TX 1 PLATE OFF

TX 1 PLATE OFF

TX 1 FAIL CLOSURE

TX 1 FAIL CLOSURE

TX 1 FAIL RELAY COIL +

TX 1 FAIL RELAY COIL -

TRANSMITTER 1

TX 2 INTERLOCK

TX 2 INTERLOCK

TX 2 PLATE ON

TX 2 PLATE ON

TX 2 PLATE OFF

TX 2 PLATE OFF

TX2 FAIL CLOSURE

TX2 FAIL CLOSURE

TX2 FAIL RELAY COIL +

TX2 FAIL RELAY COIL -

TRANSMITTER 2

CONTROLLER

TB 5

1

6

7

4

5

8

9

2

3

TX 2 ANALOG MODE

TX 2 DIGITAL MODE

TX 2 DIGITAL/ANALOG COM

TX 3 INTERLOCK

TX 3 INTERLOCK

TX 3 PLATE ON

TX 3 PLATE ON

TX 3 PLATE OFF

TX 3 PLATE OFF

TRANSMITTER 3

CONTROLLER

TB-6

1

8

9

6

7

4

5

2

3

TB6 COM

MUTE ALL

RMT AUTO KILL

TX 1 OFF TALLY

TX 2 OFF TALLY

INTERLOCK 1 REVERSE

INTERLOCK 2 REVERSE

INTERLOCK 3 REVERSE

REJECT LOAD INTLK

AUX

COAX SWITCH CONNECTIONS FOR FM CONTROLLERS

CONTROLLER Px

P1-1

P1-6

P1-7

P1-8

P1-9

P1-2

P1-3

P1-4

P1-5

SW1 POS 1 TALLY

SW1 POS 1 TALLY

SW 1 POS 2 TALLY

SW 1 POS 2 TALLY

SW1 POS 1 COMMAND

COMMAND COM

SW1 POS 2 COMMAND

FUSED 120 VAC

NEUTRAL

DIELECTRIC

50000

DC COMMANDS

DIELECTRIC

60000

DC COMMANDS

DIELECTRIC

50000

AC COMMANDS

DIELECTRIC

60000

AC COMMANDS

D

A

C

N

B

M

L

R

S

3

13

4

11

12

15

16

D

A

B

M

L

R

S

C

23

24

11

12

15

16

22

DELTA

1

4

9

3

2

6

ANDREW

1

3

2

14

15

4

5

MCI

B

E

A

C

D

L

M

H

J

ANDREW REQUIRES REVERSE POLARITY HEADER

ANDREW 24VDC ONLY

DELTA 120VAC ONLY

MCI MAY HAVE 5V CONTROL RELAY - CHANGE TO 12V OR

24V

TERMINAL NUMBERS FOR DELTA, ANDREW, MCI MAY NOT

BE CORRECT FOR EVERY MODEL

TX 1

TX 2

TX 1

TX 2

14

COMBINED ANTENNA

FRONT PANEL INDICATORS

TRC-3

ANT

TX 1

COMBINER

REJECT

LOAD

TX 3

DUMMY

LOAD

TX 2

COMBINED LOAD

COMBINER

REJECT

LOAD

TX 3

DUMMY

LOAD

SEPARATE TX 1 SEPARATE TX 2

ANT

TX 1

COMBINER

REJECT

LOAD

TX 3

DUMMY

LOAD

TX 2

COMBINER

REJECT

LOAD

TX 3

DUMMY

LOAD

ANT

ANT

LOGIC TABLES TRC-3

TRANSMITTER INTERLOCK LOGIC TABLES FOR ALL COMBINATIONS OF COAX SWITCH REVERSE

JUMPERS ON TB2

CAN ALSO BE USED AS COMMAND LOGIC TABLES-

SWITCH CABLES ARE ALL WIRED THE SAME; THE CONTROLLER IS SET

TO WORK WITH COAX SWITCH POSITIONS BY REAR PANEL JUMPERS

RUN = INTERLOCK TERMINALS CLOSED,

TRANSMITTER ENABLED

MUTE = TRANSMITTER NEVER ENABLED

MUTE L = MUTE, BUT TRANSMITTER

ENABLED WHEN LOAD IS ON

SYSTEM COMMANDS SWITCHES

NO

JUMPERS

COMBINED ANTENNA SW1 POS1

COMBINED

LOAD

SW1 POS1

SW2 POS1

SW2 POS1

SW1 POS1 SW2 POS2

SW1 POS1 SW2 POS2

SW3 POS1

SW3 POS2

SW3 POS1

SW3 POS2

SEPARATE

TX 1

SEPARATE

TX 2

SW1 POS2 SW2 POS1 SW3 POS1

SW1 POS2 SW2 POS1 SW3 POS2

SW1 POS2 SW2 POS2 SW3 POS1

SW1 POS2 SW2 POS2 SW3 POS2

TRANSMITTER INTERLOCKS

TX 1 TX 2 TX 3

RUN

MUTE L

RUN

MUTE L

MUTE L

RUN

RUN

MUTE L

INVALID

MUTE L

RUN

MUTE

MUTE

SYSTEM COMMANDS SWITCHES

REVERSE

SW1

JUMPER

COMBINED ANTENNA SW1 POS2

COMBINED

LOAD

SW1 POS2

SW1 POS1

SW1 POS1

SW2 POS1 SW3 POS1

SW2 POS1 SW3 POS2

SW2 POS1 SW3 POS1

SW2 POS1 SW3 POS2

SEPARATE

TX 1

SEPARATE

TX 2

SW1 POS2 SW2 POS2 SW3 POS1

SW1 POS2 SW2 POS2 SW3 POS2

SW1 POS1 SW2 POS2 SW3 POS1

SW1 POS1 SW2 POS2 SW3 POS2

TRANSMITTER INTERLOCKS

TX 1 TX 2 TX 3

RUN

MUTE L

RUN

MUTE L

MUTE L

RUN

RUN

MUTE L

INVALID

MUTE L

RUN

MUTE

MUTE

SYSTEM COMMANDS SWITCHES

REVERSE

SW3

JUMPER

COMBINED ANTENNA SW1 POS1

COMBINED

LOAD

SW1 POS1

SW2 POS1

SW2 POS1

SW1 POS1 SW2 POS2

SW1 POS1 SW2 POS2

SW3 POS2

SW3 POS1

SW3 POS1

SW3 POS2

SEPARATE

TX 1

SEPARATE

TX 2

SW1 POS2 SW2 POS1 SW3 POS1

SW1 POS2 SW2 POS1 SW3 POS2

SW1 POS2 SW2 POS2 SW3 POS2

SW1 POS2 SW2 POS2 SW3 POS1

TRANSMITTER INTERLOCKS

TX 1 TX 2 TX 3

RUN

MUTE L

RUN

MUTE L

MUTE L

RUN

RUN

MUTE L

INVALID

MUTE L

RUN

MUTE

MUTE

SYSTEM COMMANDS SWITCHES

REVERSE

SW1

SW3

JUMPERS

COMBINED ANTENNA SW1 POS2

COMBINED

LOAD

SW1 POS2

SW1 POS1

SW1 POS1

SW1 POS2

SW2 POS1 SW3 POS2

SW2 POS1 SW3 POS1

SW2 POS1 SW3 POS1

SW2 POS1 SW3 POS2

SW2 POS2 SW3 POS1

SEPARATE

TX 1

SEPARATE

TX 2

SW1 POS2 SW2 POS2 SW3 POS2

SW1 POS1 SW2 POS2 SW3 POS2

SW1 POS1 SW2 POS2 SW3 POS1

TRANSMITTER INTERLOCKS

TX 1 TX 2 TX 3

RUN

MUTE L

RUN

MUTE L

MUTE L

RUN

RUN

MUTE L

INVALID

MUTE L

RUN

MUTE

MUTE

SYSTEM COMMANDS SWITCHES

REVERSE

SW2

JUMPER

COMBINED ANTENNA SW1 POS1

COMBINED

LOAD

SW1 POS1

SW2 POS2

SW2 POS2

SW1 POS1 SW2 POS1

SW1 POS1 SW2 POS1

SW3 POS1

SW3 POS2

SW3 POS1

SW3 POS2

SEPARATE

TX 1

SEPARATE

TX 2

SW1 POS2 SW2 POS2 SW3 POS1

SW1 POS2 SW2 POS2 SW3 POS2

SW1 POS2 SW2 POS1 SW3 POS1

SW1 POS2 SW2 POS1 SW3 POS2

TRANSMITTER INTERLOCKS

TX 1

RUN

MUTE L

TX 2

RUN

MUTE L

TX 3

MUTE L

RUN

RUN

MUTE L

INVALID

MUTE L

RUN

MUTE

MUTE

SYSTEM COMMANDS SWITCHES

REVERSE

SW1

SW2

JUMPERS

COMBINED ANTENNA SW1 POS2

COMBINED

LOAD

SW1 POS2

SW1 POS1

SW1 POS1

SW1 POS2

SW2 POS2 SW3 POS1

SW2 POS2 SW3 POS2

SW2 POS2 SW3 POS1

SW2 POS2 SW3 POS2

SW2 POS1 SW3 POS1

SW1 POS2 SW2 POS1 SW3 POS2

SEPARATE

TX 1

SEPARATE

TX 2

SW1 POS1 SW2 POS1 SW3 POS1

SW1 POS1 SW2 POS1 SW3 POS2

TRANSMITTER INTERLOCKS

TX 1

RUN

MUTE L

TX 2

RUN

MUTE L

TX 3

MUTE L

RUN

RUN

MUTE L

INVALID

MUTE L

RUN

MUTE

MUTE

SYSTEM COMMANDS SWITCHES

REVERSE

SW2

SW3

JUMPERS

COMBINED ANTENNA SW1 POS1

COMBINED

LOAD

SW1 POS1

SW2 POS2

SW2 POS2

SW1 POS1 SW2 POS1

SW1 POS1 SW2 POS1

SW1 POS2 SW2 POS2

SW3 POS2

SW3 POS1

SW3 POS1

SW3 POS2

SW3 POS1

SEPARATE

TX 1

SEPARATE

TX 2

SW1 POS2 SW2 POS2 SW3 POS2

SW1 POS2 SW2 POS1 SW3 POS2

SW1 POS2 SW2 POS1 SW3 POS1

TRANSMITTER INTERLOCKS

TX 1 TX 2 TX 3

RUN

MUTE L

RUN

MUTE L

MUTE L

RUN

RUN

MUTE L

INVALID

MUTE L

RUN

MUTE

MUTE

SYSTEM COMMANDS SWITCHES

REVERSE

SW1

SW2

SW3

JUMPERS

COMBINED ANTENNA SW1 POS2

COMBINED

LOAD

SW1 POS2

SW1 POS1

SW1 POS1

SW1 POS2

SW2 POS2 SW3 POS2

SW2 POS2 SW3 POS1

SW2 POS2 SW3 POS1

SW2 POS2 SW3 POS2

SW2 POS1 SW3 POS1

SEPARATE

TX 1

SEPARATE

TX 2

SW1 POS2 SW2 POS1 SW3 POS2

SW1 POS1 SW2 POS1 SW3 POS2

SW1 POS1 SW2 POS1 SW3 POS1

TRANSMITTER INTERLOCKS

TX 1 TX 2 TX 3

RUN

MUTE L

RUN

MUTE L

MUTE L

RUN

RUN

MUTE L

INVALID

MUTE L

RUN

MUTE

MUTE

16

5 COIL

4 NC

1 COM

3 NO

2 COIL

EXP

EXP

EXP

CPU

DRAWN BY

TUNWALL RADIO LLC

TRC-3

3-SWITCH FM CONTROLLER Sept 2007

S. TUNWALL

Component layout

IB-426-Rev D

P/N 85171

Model 60000

Motorized Coaxial Switches

1 5/8”, 3 1/8”, 4 1/16” and 6 1/8”

Instruction Manual

2/10/03

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC

Table of Contents

4.0

5.0

6.0

7.0

1.0

2.0

3.0

General Description ...........................................................................................................2

Specifications .......................................................................................................................3

Theory of Operation ......................................................................................................... 3

Installation ...........................................................................................................................3

Operation .............................................................................................................................3-4

Maintenance and Repairs ..................................................................................................4

Ancillary Equipment ..........................................................................................................5

Fig. 1

Fig.2

Outline Drawing .................................................................................................................6

Wiring Diagram ..................................................................................................................7

Wiring Table ........................................................................................................................8

Wiring Details .....................................................................................................................9

Note: All specifications are for reference only. Consult factory for details.

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC

WARNING

All Electrical and RF work must be done in accordance with local and national codes and safety requirements.

1.0 General Description

The Model 60000 Coaxial Switch provides reliable and fast switching of coaxial transmission line systems. It is a motor driven rotary type and can be controlled locally or remotely.

Operable in any position and having a minimum of moving parts, the switch will routinely operate through 1,000,000 cycles without failure.

The switch is equipped with a manual over-ride, mechanical position indicators and with auxiliary read-out circuits.

EIA male flanges are standard with adaptors available to mate with unflanged or semiflex transmission lines.

2.0

Specifications

Frequency Range

Characteristic Impedance

VSWR Max.

Insertion Loss

Power Rating

Peak

Average at 30 MHz

Average at 300 MHz

Average at 900 MHz

Switching Time (nominal)

1 5/8"

DC-900 MHz

50 Ohm

150 kw

25 kw

6 kw

4 kw

3 seconds

3 1/8"

DC-900 MHz

50 Ohm

500 kw

90 kw

30 kw

15 kw

3 seconds

4 1/16"

DC-800 MHz

50 Ohm

1.05:1

0.1 dB max.

1000 kw

150 kw

50 kw

25 kw

3 seconds

6 1/8"

50 Ohm

DC-800 MHz

50 Ohm

2000 kw

300 kw

100 kw

45 kw

4 seconds

6 1-/8"

75 Ohm

DC-800 MHz

75 Ohm

1500 kw

225 kw

75 kw

38 kw

4 seconds

Isolation

RF Connectors

Drive Motor Current

1

-50/60 Hz at 115 V AC at 230 V AC

Auxilary Switch Ratings

Net Weight

Gross Packed Weight

Gross Packed Cube

60 dB

EIA Male

36 lbs

16 kg

48 lbs

21.7 kg

3.58 ft 3

.10 m 3

Run Current

115 Nom. .6 AMP

230 Nom. .5 AMP

47 lbs

21.5 kg

65 lbs

29.5 kg

3.58 ft 3

.10 m 3

2

120 VAC 3A

28 VDC 3A

60 lbs

27 kg

85 lbs

38 kg

9 ft 3

.26 m 3

Start

115 Nom. 1.25 AMP

230 Nom. .9 AMP

130 lbs

59 kg

185 lbs

84 kg

12.6 ft 3

.35 m 3

120 lbs

54 kg

170 lbs

77 kg

12.6 ft 3

.35 m 3

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC

3.0 Theory of Operation

The Model 60000 Coaxial Switch is a rotary type switch having an aluminum RF cavity common to all ports. The rotor assembly contains two inner conductor blades and a common isolating ground plane which oscillates 90° to accomplish the switching function and provide isolation between transmission line paths.

2. The manual operate handle stub should be in an accessible location for manual switching in the event of control power failure. Provide a minimum of eight inches of clearance above the top of the motor drive cover to allow for removal.

3. After the switch is properly mounted in position, remove hardware and protective covers from the RF connectors.

The rotor is driven by a gear motor. When the motor is activated by connection through the control, it will rotate 90°.

Six normally open microswitches are provided for position confirmation. The rotor activates these microswitches; and they must not be used for transmitter interlocking. One must ensure that RF power is off before a position command is activated. Dielectric cannot be responsible for failure or burnout of switches switched under power.

4. Attach adaptors or EIA female flanged lines to the switch ports and re-install hardware.

5. Note: The RF contact of the switch flanges protrudes above the flange surface and when properly connected there will be a space between the flanges at the bolt circle. Tightening beyond rated torque will destroy both the switch flange and the mating transmission line flange.

CAUTION

3.1 Inside the Drive

The drive used on the 60000 switches is an AC power segregated AC/DC command actuator. The drive is operated by 115 VAC, OR 230 vac and controlled by 12-24 VDC or 115/230 VAC. The different voltages can be selected without removing the cover. See the schematic for pin out for the configuration required. Do not apply AC and DC commands to the drive at the same time.

There is no need to open the switch unless local push button operation is required.

4.0 Installation

Tighten bolts evenly and do not exceed torque rating of eleven

(11) foot pounds on the 1 5/8” switch or twenty (20) foot pounds on the 3 1/8”, 4 1/16” and

6 1/8” switches

.

5.0 Operation

The 1 5/8”, 3 1/8”, 4 1/16” AND 6-1/8” Model

60000 switches will change positions in approximately three seconds upon command.

1. The switch may be mounted in any convenient position using the four mounting holes shown in

Figure 1. Orient the RF ports to meet the required transmission line layout.

The interlock circuits should be employed to prevent RF power being applied unless a legitimate RF transmission line path has been completed through the switch to an antenna or dummy load. Ensure that RF is off before the switch is commanded for position change.

Warning! User must remove all RF power before switching!

3

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC

The 60000 series can be operated in four ways.

1. Locally with the cover removed.

2. Locally with the S60 Pendant. This device does not include any provisions for interlocks.

3. Remotely with connection through the Amp connector.

4. Manually with a 3/8” wrench or optional hand wheel.

6.0 Maintenance and Repairs

The Model 60000 Switch requires no periodic maintenance. However, after the initial installation is complete, the cover should be removed and the switch inspected for loose electrical connections and/or auxiliary switch hardware.

To operate the switch locally with cover removed:

A. Remove AC power and remove the cover.

B. Set the “Man Run” switch to “Man”. Plug in

AC power

C. Press either the “CW or CCW” button to desired position and hold until the motor stops.

D. Reset “Man Run” switch to “Run” and replace cover when done.

To operate with the S60 Pendant:

A. Connect Amp connector and AC power.

B. The active side pilot light will illuminate.

C. Select the desired position. Indicator lights will change status as switch moves.

To operate through Amp connector:

A. Connect Amp connector and apply AC power.

B. Connect control end cable and operate through control.

To operate manually:

A. Assure AC power and Amp connectors are unplugged.

B. Using wrench or hand wheel press down and turn until pointer on cover lines up with desired position.

WARNING

Removal of the cover may expose live electrical terminals (240V AC maximum).

Some sub-assemblies of the units are sealed at the factory after test; breaking these seals voids any warranty and field repair of these assemblies is not recommended.

4

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC

7.0

Ancillary Equipment*

Description

Part

Number

Adaptors

1 5/8” EIA-F

3 1/8” EIA-F to 1 5/8” no flange, 6” large to 1 5/8” EIA-F, 6” large to 3 1/8” no flange, 6” large to 3 1/8” EIA-F, 6” large

B-44920-502

D-30997-001

B-44900-502

C-7999-501

4 1/16” EIA-F

Transitions

1 5/8” EIA-M

3 1/8” EIA-F

3 1/8” EIA-M

4 1/16” EIA-F

Cable

to Type N-F to 1 5/8” EIA-F, 6” large to Type N-F

C-21109-503

B-25623-501

C-14397-503

Dual Switch Controller to 60000 Switch-25'

Dual Switch Controller to 60000 Switch-50'

0101873-025

0101873-050

To adapt 60000 switch CPC 24 pin to 16 pin AMP CPC ("Type C") 85156

To adapt 60000 switch to 50000 amphenol connector 85144

S60 Pendant Control

Extension Cable

10' AMP connector cable, AC power cable, and switch box.

25' Eight conductor cable assembly for longer S60 pendant applications.

85145

85157

*All components are copper; similar items having aluminum outer conductors are available. Contact

Dielectric Communications for a complete line of coaxial and waveguide transmission lines and components.

5

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC

Figure 1

6

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC

Figure 2

Note:

1.

The actuator only requires a ½ second command pulse to latch the control in. A maintained command will not harm the unit.

2.

Do not apply AC and DC commands at the same time.

3.

For AC command between 110 VAC and 230 VAC, hook the common AC conductor to Pin 13 and position 1 and 2 commands to pins 22 and 23.

4.

For DC command between 12 and 24 VDC, hook the negative conductor to pin 13 and the position 1 and position 2 to pins 3 and 4.

The actuator has been tested to operate at 10% less than the rated input voltage and is dual rated for 50/60 Hz operation.

7

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC

8

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC

Dielectric Communications • 22 Tower Road • Raymond, ME 04071 • (207) 655-4555 • (866) DIELECTRIC