TMT TA Series Operating Manual
TMT TA Series is a versatile crane scale designed for industrial and commercial applications with a durable construction, ensuring accuracy and reliability in demanding environments. It features a large, easy-to-read LCD display, allowing for clear visibility in various lighting conditions. With its wireless connectivity, it offers remote control and data transfer capabilities, enhancing productivity and efficiency.
Advertisement
Advertisement
MEMO
- 20 -
TA series
V106
CRANE SCALE
Operating Manual
www.tmteng.com
- 1 -
◆ Wireless specification
RF frequency range
Output power
Channel width
Frequency offset
Transmit data rate
Receiver sensitivity
Maximum input level
RF In/out impedance
Spurious(2nd harmonics)
Radio link effective range
2400 ~ 2483.5 MHz
Max. 4dBm
2 MHz
< ±30ppm
250Kbps,500Kbps
-99dBm (PER <1%)
0dBm
50 ohm (TXRF, RXRF)
< -30dBm
Approx. 100M (Open space)
- 18 -
1. Instruction
This operating manual is the specifications for our TA series.
The TA series is the product of years of design, development, and complete testing.
This TA series has been designed with reliability, under rigid quality control and with outstanding performance.
This MANUAL included with basic technical information about composition of hardware and programmatic functions.
■ Precaution
Please check if the safety hook is connected well before you install our TA series, so that the SHACKLE is not separated.
◆ Don’t install the TA series in direct sunlight.
◆ Avoid sudden temperature changes, vibration, wind, water, or excessive dirt.
◆ Avoid from the shock of excessive weight.
◆ Place the scale away from water.
◆ Weigh a thing on the scale in vertical direction as follows.
(Refer to following picture.)
- 3 -
9. Remote Control
(1) How to use
■ : Used to power off the scale
(Power-ON is available only on scale.)
■ : Same as Keyboard
■ : Same as Keyboard
■ : Same as Keyboard
■ (CLEAR) : Used to clear previously added weights.
■ : SUM KEY : Used to add weights.
If press a SUM KEY, the sum of weights is displayed.
After that, about 2 sec later, a weighing mode is reverted.
(2) Specification
List
Available Distance
Available Angle
Power
Battery for a Remote Control : AA size, 1.5V, 2 pcs
Description
6 m ∼ 10 m
60 °
3V (1.5V AA 2pcs)
- 16 -
3. Technical Specifications
◆ Overall View
◆ Size
TA100/500 TA200
TA100/500 TA200
- 5 -
■ F16 : Initialization of number measured daily (weigh No.) - Wireless option
Setting Menu
F16-0
Description
Maintain current number
F16-1 Initialization (starting from No.1)
■ F17 : Auto print - Wireless option
Setting Menu
F17-0
F17-1
Description
Not used
Auto print (include print format)
F17-2
F17-3
Auto print (only weight data)
Wireless Auto print (include print format)
F17-4 Wireless Auto print (only weight data)
■ F18 : Hold data auto print - Wireless option
Setting Menu
F18-0
F18-1
Not used used
Description
8. Testing Mode
(1) How to use
■ Press the (TARE Key) with the (ON/OFF Key).
Then, the scale switches into a Testing Mode.
(2) Keyboards
■ SET : Used to move into next menu.
■ ZERO , TARE , HOLD : Used when the scale is been testing.
(3) Testing Menu (TEST 1 – TEST 6)
■ TEST 1 : Keyboard Test
KEY
Display Description
ZERO
TARE
HOLD
If you push the button that you want to test, the key number is appeared on the display.
If press the (SET Key), it moves into TEST 2.
SET
- 14 -
4. Display and Keys
◆
Display Description
Weight Displays the accurate weight
ZERO
TARE
HOLD
STABLE Displays that weight is Stable
ZERO
TARE
HOLD
Displays that current weight is Zero
Displays the net weight, when the tare is included
Used to weigh an unstable or moving thing
BATTERY Displays when a battery has to be recharged
◆
Key Function
Key Description
ON/OFF Turn on and off the scale
ZERO Reset scale to zero
TARE Input a tare weight
HOLD Weigh an unstable and moving thing (Manual / Auto)
SET Testing Mode or Returning a new Mode
- 7 -
■ F05 : Backlight Mode (0~2)
Setting Menu
F05-0 Manual ON/OFF
Description
F05-1
F05-2
Automatic ON/OFF (weighing : ON / zero : OFF)
Backlight ON.
■ F06 : Automatic Zero Condition (00~99)
Setting Menu
F06-00
…
F06-23
No compensation
Description
Compensation for gradual change below 1 division for 3
…
F06-99 Compensation for gradual change below 4.5 division for 9
■ F07 : Auto Hold Start
Setting Menu
F07-0 Manual
F07-1 Automatic
■ F08 : Initialization Hold Weight (1~9)
Description
Setting Menu
F08-0
…
Zero (0)
F08-3
…
Below 3 division
F08-9 Below 9 division
■ F09 : Function * key - Wireless option
Description
Setting Menu
F09-0
F09-1
Description
Use to clear previously added weights.
Print command key
F09-2
F09-3
F09-4
F09-5
Weighing data send to computer
Wireless print command key (include print format)
Wireless print command key (only weight data)
Used to clear previously added weights.
■ F10 : Device number (Identification number of each scale) - Wireless option
Description Setting Menu
F10-0
…
F10-5
…
F10-9
Device No.0
Device No.5
Device No.9
- 12 -
6. General Functions and Description
(1) Operating Method
■ Press the (ON/OFF Key) on the front panel of the scale. The scale will be ready for weighing when ZERO lamp is on.
(2) ZERO Function
■ If press the (ZERO Key), the ZERO is displayed after correcting zero range by itself. The Zero range is corrected within 2% of maximum weight.
If weigh is unstable, the ZERO Key doesn’t work.
(3) Setting Function of Tare Weight
■ Place the tare on hook and push the (TARE Key). Then, the TARE is displayed and the display turns ZERO state.
■ In order to delete the tare weight, remove the tare or a thing to be weighted on the hook and press the (TARE Key).
The TARE is off and the scale returns in normal mode.
If weight is unstable, (TARE Key) doesn’t work.
The sum of both a tare weight and a weighing weight cannot be exceeded over the
maximum capacity of the scale.
(4) Zero Calibration Function
■ Under the ZERO state (ZERO lamp is on.), if the weight change is below the half of the scale graduations, the scale turns automatically Zero.
- 9 -
(5) HOLD Function
① Auto-Hold Function
(This function works every time the scale weighs all the things.)
■ Under the Zero state, press the (HOLD Key).
■ The weight display will indicate the
■ is displayed.
message.
■ After placing a thing on hook, if the weight change is stable, then a display shows the message and average weight will appear.
■ The weight of a held thing is displayed.
■ In order to escape from the Auto-Hold function, push the HOLD key under the
is ZERO state. Then, after the message will be displayed, the off and the scale turns into normal mode.
② Manual-Hold Function
(Only when you press a HOLD key, the HOLD function works.)
■ Place a thing on hook and press the (HOLD Key).
The message appears and the weight appears.
is displayed. The Average
■ The held weight is displayed.
■ In order to escape from the Manual-Hold function, remove a thing or press the
( HOLD Key). Then, the mode.
is off and the scale returns into the normal
- 10 -
7. Setting Mode
(1) How to use
■ Press the (HOLD Key) with the (ON/OFF Key).
Then, the scale switches into Setting Mode.
(2) Keyboard
■ ZERO : Used to initialize the scale to ZERO.
■ SET : Used to save the setting constant changed and to move into next setting menu.
■ HOLD : Used to increase the setting constant one by one.
(3) Setting Menu (F1 – F18)
■ F01 : Adjustment the speed of weight change (1∼9)
Setting Menu
F01-1
…
F01-5
Very fast
Normal
…
F01-9 Very slow
■ F02 : Weight Storage Function
Description
Setting Menu
F02-0
F02-1
Not used
Use
■ F03 : Adjustment the hold speed (1∼9)
Description
Setting Menu
F03-1
…
F03-5
Very fast
Normal
…
F03-9 Very slow
■ F04 : Stable condition set of weight (1~9)
Description
Description Setting Menu
F04-1
…
F04-5
…
F04-9
Sensitive
Normal
Insensitive
- 11 -
5. Use of Battery Charging
(1) How to charge a battery
■ Check the power supply (AC : 100V~240V)
■ If adaptor is still being charged, the RED lamp is on as a below picture.
■ If a charging is completed, the GREEN lamp is on.
The battery charging time takes about 5hr.
(The battery charging time is subject to be changed according to battery condition.)
Charging Completed
(2) Charger (Lithium polymer battery)
Capacity 4000mAH
Power 3.7V
(3) “LOW BATTERY” Sign
■ In order to prevent a battery being overcharged, the sign is displayed.
After 6 hours later, power is automatically off. (It’s subject to be changed according to the using condition.)
- 8 -
■ F11 : Item number (Identification number of each Item) - Wireless option
Setting Menu
F11-0 Item No.0
Description
…
F11-5
…
Item No.5
F11-9 Item No.9
■ F12 : Data set sent to computer - Wireless option
Setting Menu
F12-0
F12-1
F12-2
F12-3
No data output
Command mode
Description
Transmission in an state of stable & unstable.
Transmission only in stable state
■ F13 : Wireless real time communication - Wireless option
Setting Menu
F13-0
F13-1
Not used
Auxiliary display
Description
F13-2 TF200 (Wireless dongle)
■ F14 : Print line feed - Wireless option
Description Setting Menu
F14-0
…
1 line feed
F14-5
…
6 line feed
F14-9 10 line feed
■ F15 : Print form - Wireless option
Setting Menu
F15-0
F15-1
F15-2
[FORM 0]
001, ID_9, 25 kg
Description
Form 0 (serial No., Item No., weight)
Form 1 (weigh No., Item No., weight)
Form 2 (weight)
[FORM 1]
SN_012, ID_9, 25 kg
[FORM 2]
25 kg
62 kg
- 13 -
◆ Specification
Model #.
TA-100
(General Type)
TA-200
(Meat Shop Type)
TA-500
(General Type)
Capacity
(Graduations)
0 ~ 100kg (0.05kg) 0 ~ 200kg (0.1kg)
0 ~ 250kg (0.1kg)
250 ~ 500kg (0.2kg)
Weight 2.6kg
Maximum Tare
Weight
Operating Time
Display
Temperature
Keys
Display
Full Tare
350 hr
5 Characters, LCD, (Character Size : 20mm)
-10℃ ~ 40℃
ON/OFF, ZERO, TARE, HOLD, * (Back-light)
LOW BATT, BATTERY State, ZERO, NET, HOLD, STABLE,
“-“ (Minus)
Accessories
Zero Point
Rechargeable Battery
Within +/- 2% of Maximum Weight
Initial Zero Point Within +/- 10% of Maximum Weight
Adaptor Power
Supply
Input : AC 100V~240V, 50/60Hz
Output : 5V 1000mA
◆
Part List
1) Crane Scale : 1 EA
2) Adaptor : 1 EA
3) Infra Red Remote Controller : 1EA
- 6 -
■ TEST 2 : Display Test
Display Description
TEST 2 operates automatically and the whole display is ON.
If press the (SET Key), it moves into TEST 3.
■ TEST 3 : A/D Conversion Test (Load Cell Test)
Display Description
The value is the conversion constant for A/D.
The value may be different according to scale models.
If press the (SET Key), it moves into TEST 4.
Please check if the displayed number is changed well with giving some force to the hook. If the displayed number is not changed and remains “0”, then it needs the service after sales. Therefore, contact us.
■ TEST 4 : Backlight Test
화면 설명
: Backlight ON/OFF
If press the (SET Key), it moves into the weighing mode.
■ TEST 5 : RS232C TEST
Display Description
Ex) 49-13 : Transmit 49 (ZERO KEY)
Receiver 13 (PC ENTER KEY)
(ZERO KEY 49, TARE KEY 50, HOLD KEY 51)
■ TEST 6 : Wireless communication test - Wireless option
Press (ZERO KEY) at the scale. The numeric character increases on the auxiliary display.
- 15 -
2. Main Features
◆ Super mini small size and portable
◆ Lithium polymer battery built-in => Long battery lifetime by one-time charging.
◆ Convenient Charging Method
Auto Charging after connecting a rechargeable adaptor
(Charging Time : approx. 5 hr)
Auto Power Cut-Off after the charging is completed.
(Full Charging lamp displays.)
◆ Very easy to exchange the used Shackle in a new one.
◆ As per the using purpose, General Type (TA-100,500), Meat Shop (TA-200)
- 4 -
10. RS232C & Wireless option
■ RS-232C port connection
Connect serial port of the scale to serial port of PC as follows.
(RED) TXD ------------------------------ RXD (2)
(WHITE) RXD ------------------------------ TXD (3)
(GREEN) GND ------------------------------ GND (5)
[RS232C wire of TA] [Serial port of computer]
■ Data format
Type : EIA-RS-232C
Method : Full-duplex, asynchronous transmission Format
① Baud rate : 9600 bps
② Data bit: 8, Stop bit: 1, Parity bit: None
③ Code : ASCII
④ When data is sent to computer? Set in SET mode(F12).
⑤ Format (18byte)
Start code Blank Lamp status Weighing data Unit
S(U) T(S) , , +/7byte k g
- Start code : ST (Stable) / US (Unstable)
- Lamp status byte
Bit7 Bit6 Bit5
One decimal
Two decimal
Three decimal
Bit4 Bit3
Stable
Bit2
Zero
Bit1
Tare
Bit0
Hold point point point
- Weighing data (8byte)
a. 13.5 ㎏ : '+', ' ', ' ', ' ', '1', '3', '.', '5'
b. 135 ㎏ : '+', ' ', ' ', ' ', ' ', '1', '3', '5'
c. -135 ㎏ : '-', ' ', ' ', ' ', ' ', '1', '3', '5'
- 17 -
Stop code
CR LF
INDEX
1.
Instruction ················································································ 3
2.
Main Features ·············································································· 4
3.
Technical Specifications ······························································· 5
4.
Display and Keys ···········································································7
5.
Use of Battery Charging ···································································8
6.
General Function and Descriptions ·····················································9
7.
Setting Mode ··············································································11
8.
Testing Mode ············································································· 12
9.
Remote control············································································ 13
10.
RS232C & Wireless option ·····························································14
11.
Error Message and Self-Testing methods ···········································14
- 2 -
11. Error Message and Self Testing methods
▣ Error 1 z Message : Data in an internal storage allocation are erased owing to any electrical impact. z Self-Testing Method : Please contact us to resolve this technical problem.
▣ Error 2 z Message : something wrong in a Load Cell connection or in an A/D conversion. z Self-Testing Method : Please contact us to resolve this technical problem.
▣ Error 3 z Message : The initial zero range is exceeded within +/- 10% of maximum weight value. z Self-Testing Method : Please check if a book is empty.
▣ Error z Message : When a thing is over-weighed within the maximum weight value, the error message is displayed. z Self-Testing Method : Do not weigh the thing whose the limit of a maximum weight value is exceeded.
If a load cell is broken, then the load cell has to be replaced.
- 19 -

Download
Advertisement