Pentair AURORA 3500 Series Instruction, Installation, Maintenance And Repair Manual
Advertisement
Advertisement
3500 SERIES
MODEL 3550 ASME/ANSI B73.1
FRAMES S, M, L AND XL
INDUSTRIAL PROCESS PUMPS
INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL
NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system.
Part # A-03-339 | © 2015 Pentair Ltd. | 07/06/15
3500 SERIES / MODEL 3550
INDEX:
Warnings .............................................................................................................................................................. 3
Introduction ......................................................................................................................................................... 4
Installation ....................................................................................................................................................... 4–8
Operation ......................................................................................................................................................... 8–9
Maintenance ...................................................................................................................................................... 10
Disassembly & Assembly ............................................................................................................................ 10–17
Installation Troubleshooting Guide ................................................................................................................ 18
Cross Sectional Illustrations ...................................................................................................................... 19–20
Parts & Material Composition ........................................................................................................................ 21
Spare Parts ........................................................................................................................................................ 21
Appendix I ......................................................................................................................................................... 22
Appendix II .................................................................................................................................................. 22–23
Appendix III ...................................................................................................................................................... 23
Appendix IV ...................................................................................................................................................... 24
Appendix V ........................................................................................................................................................ 24
Appendix VI ...................................................................................................................................................... 25
Appendix VII ..................................................................................................................................................... 26
Warranty ........................................................................................................................................................... 27
PUMP DESCRIPTION:
Fill this in for your record purposes: It will be critical to have this information for the accurate identification of spare parts which may be required later.
Pump Size:
Serial Number:
Impeller Diameter:
Flow:
Application:
Mechanical Seal Type:
Model:
Date Received:
RPM:
Head:
Material of Construction*:
*Nameplate includes material information for shaft (left) and wet end (right) in that order.
2
3500 SERIES / MODEL 3550
NOTICE:
Aurora model 3550 pumps MUST be installed only in systems that have been designed by qualified engineering personnel.
The system MUST conform to all applicable local and national regulations and safety standards.
This manual is intended to assist in the installation, operation and maintenance of Aurora model 3550 pumps and MUST be kept with the pump.
Pump service shall be performed by qualified technicians
ONLY. Service shall confirm to all applicable local and national regulations and safety standards.
Thoroughly review this manual, all instructions and hazard warnings BEFORE performing any work on the pump.
Maintain ALL system and pump operation and hazard warning decals, signs, placards, etc.
This is a SAFETY ALERT SYMBOL.
Read and understand all warnings before installation or servicing pump. Failure to follow the warnings in this manual caould cause personal injury, death, or major property damage.
Danger:
Will cause personal injury or death and major property damage.
Warning:
Can cause serious injury and major property damage.
CAUTION
Can cause personal injury or property damage.
NOTICE:
Follow special instructions as they are very important and must be followed.
Warning: Toxic Fluid Handling
Hazardous or toxic fluids must be flushed and properly disposed of before performing service to the pump. Check local and national regulations on disposal regulations for your area. Clean all contaminated parts according to local and national regulations. Isolate pump by closing the suction and discharge valves before servicing the pump. Wear personal protective equipment when there is a potential of handling hazardous or toxic materials.
Warning: Cut Power
Lock out power to the driver prior to performing work on the pump. Accidental start could occur if power is not locked out, causing personal injury. Always wear proper safety equipment including glasses, gloves, shoes and respirators. Do not touch pump while in operation. Lockout or uncouple driver prior to personal contact with unit. Be careful of any odd shaped or sharp edges. Avoid contact with the rotating components in the seal chamber area. All adjustments to the pump shoul be made with the pump shut and locked out.
Danger: Do Not Heat to Loosen
Do not apply heat for removal or disassembly as any trapped fluid could ignite causing an explosion.
CAUTION
Lifting/Handling of Unit
Lift the unit with a device that is capable of lifting the weight of the combined pump components.
NOTICE: This pump is intended for fluid transfer. Do not use for any other purpose than the intended applications.
OPERATIONAL SAFETY DATA:
CALIFORNIA PROPOSITION 65 WARNING:
Warning:
This product and related accesso- ries contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
CAUTION
MAINTENANCE SAFETY DATA:
Do not exceed rated pressures. Do not operate under minimum rated flow. Do not operate with discharge or suction valves closed. Do not adjust or disassemble any pressure containing component or shaft seal prior to depressurizing the system.
Warning: Relieve Pressure
Relieve system pressure prior to servicing the pump. Failure to do so can cause personal injury or property damage.
Use quality fasteners (OEM supplied) of proper size and material. Do not use force to draw piping flanges to pump as this may cause dangerous strains within the pump case and misalignment between the pump and driver. Do not disassmble or adjust any pressure containing component or shaft seal prior to relieving the pressure from the primary and auxiliary fluid systems. This will ensure no hazardous or high pressure fluid is ejected causing personal injury or equipment damage.
Warning:
Do not operate unless the suction is primed with fluid.
Never run pump dry. Do not operate without liquid supplied to the mechanical seal. Running the mechanical seal dry
(even for limited runs) can cause failure and fluid release.
Personal injury can occur.
CAUTION
Do not touch the pump while it is connected to hot or cold fluids. Doing so could cause personal injury.
3
INTRODUCTION:
RECEIVING SHIPMENT: Upon receiving shipment, check items against packing list. Be sure to inspect entire box for any additional parts and read all special instruction tags attached to the pump.
STORAGE: If the unit will not be installed immediately, the unit should be kept dry and in the shipping container until ready for installation.
HANDLING:
CAUTION
Heavy pumps and components. Serious injury or damage to the equipment could result from improper lifting and support.
You may hoist the isolated pump using the eyebolt in the bearing frame. If the pump is mounted on a baseplate, place a sling under the motor end and a sling under the pump end to hoist. If the pump and baseplate also contain a motor you may hoist by placing a sling under the motor end and a sling under the pump end.
Do not hoist the pump, motor and base assembly using the eyebolts in the pump or motor.
INSTALLATION:
MOTOR REQUIREMENTS AND SPECIFICATIONS:
The motor power rating cannot exceed the maximum power limitations of the pump. Consult the chart below to ensure proper power limitations.
3500 SERIES / MODEL 3550
FOUNDATION: The foundation must maintain alignment under normal and abnormal conditions as this is one of the most controlling aspects for the overall reliability of the pump. The foundation must be as heavy as possible and nonresonant so it can minimize vibration. The length and width of the foundation should project beyond the anchor bolts at least 6" (152mm) while considering a generous factor of safety when determining the thickness of the base.
Certified pump elevation drawings can be supplied. These drawings will include general information on determining the size and thickness of the base and dimensions for locating the anchor bolts.
Anchor bolts must be accurately situated and provided with sleeves. The sleeve bore diameter should be nearly double the diameter of the bolt, providing no less than .5" (13mm) clearance around the bolt.
Use an acceptable foundation for pump installation.
PROPER FOOTPRINT:
RIGHT!
cL
30º angle from pump;
L bearing area
WRONG!
cL
Base too narrow; not enough bearing area causes pump to rock
Power
Limits
Frame
HP (kW) per 100
RPM
S
1.1
(.82)
M
3.4
(2.6)
L
5.6
(4.2)
XL
14
(10.5)
NOTE: When calculating HP (kW) the pumped fluid specific gravity must be considered.
ACCEPTABLE MASS: Mass of the foundation must be at least triple the mass of the pump and motor.
RIGHT!
WRONG!
Concrete weight 150 lb./ft 3
(2408 kg/m 3 )
4
Typical Foundation
LEVELING: Acceptable parallel machined bearing plates or chock blocks need to be placed under the base along the sides and ends to distribute the load evenly. These must be leveled, lengthwise and widthwise, before installation of the base can begin.
GROUTING: The anchor bolts are for hold-down only.
The grouting withstands end thrust and side thrust while compensating for the nonuniformity between the base and the foundation, preventing the pump from shifting.
Use nonexpanding, nonshrinking and high strength grouting mixture.
Allow proper setting of grouting before tightening anchor bolts.
Check coupling alignment after tightening to ensure it has not changed. Realign as required in the Coupling Alignment instructions.
COUPLING ALIGNMENT:
Warning:
Always lock out electrical power to the driver before performing alignment. Failure to lock out power could result in serious injury.
NOTICE: Check rotation direction of the driver before coupling it to the pump. The front surface of the pump casing has indications of rotation direction. Damage to the pump will occur if the direction of rotation is not correct.
Good alignment through the flexible coupling will result in good service life of the driver and pump.
COUPLING INFORMATION:
• Use flexible type coupling for motor and pump.
• When aligning the shafts, the coupling should be disconnected and the halves should be brought into alignment.
ALIGNMENT CHECKS:
• Check cold alignment before and after grout has been applied to the baseplate.
• Prior to cold alignment piping should be connected to the pump.
3500 SERIES / MODEL 3550
• Operate the pump and driver for an adequate amount of time to achieve maximum operating temperature before the final or hot alignment is performed.
• Repeated checks of alignment should be performed to ensure proper, smooth and continuous operation.
• If any changes occur in process conditions it is recommended to perform an alignment check.
Warning:
Install coupling guard once alignment is completed. Ensure coupling guard is properly installed before operating the pump.
NOTICE: Inspect the alignment between the pump and driver to ensure no misalignment was caused in the transportation and handling of the unit.
Do not align if base and mounting flanges have not been tightened. Perform alignment when the pump and driver are at normal operating temperatures.
ALIGNMENT METHOD: There are many ways to ensure proper alignment, and specific alignment choices are the customer’s choice. If you require information on the double dial indicator method, contact the Aurora factory for details. Check
Hydraulic Institute Standards for additional information.
ALIGNMENT CRITERIA: Complete alignment occurs when the unit’s parallel and angular Total Indicator Run-out
(TIR) measures less than .005" (.13mm). Measure the parallel alignment on the rim of the coupling, and the angular alignment on the face of the coupling. Corrections need to be made if any values exceed those stated.
Warning:
Never use force to draw piping to pump flanges. This can cause excess strain on the pump case and misalignments can occur between the pump and driver resulting in serious injury and damage to the equipment.
Check Hydraulic Institute Standards for proper piping details.
PIPING FORCES AND MOMENTS: The discharge and suction piping flanges must be aligned concentric and parallel to the pump flanges. All piping must be independently supported near the pump to eliminate any forces that could be transmitted to the pump after the nuts and bolts have been securely fastened. Always tighten bolts 180° across from each other in an alternating fashion to ensure even gasket compression.
The piping system must be designed to allow for thermal expansion while not creating excessive forces on the pump due to the expansion/contraction, or the weight of the pipe and fluid.
NOTICE: Do not draw the piping to the pump by force.
Excess forces and moments on the pump will reduce seal and bearing life.
5
loops.
3500 SERIES / MODEL 3550
Excess forces and moments on the pump may occur due to:
• Thermal expansion and contraction of the piping indicating improper piping design and/or lack of expansion joints or
• Improper pipe support due to use of rod hangers (instead of spring hangers), anchors or restraints used when installing the piping.
• Misalignment of the pump suction and discharge flanges to the piping flanges.
SUCTION PIPING:
• Suction piping should not be less than the size of the pump suction nozzle. Suction piping should be no more than one size larger than the pump suction nozzle.
• Suction line velocities should not exceed 10 ft./sec. This will prevent cavitation of the pump.
• Fluid velocity guidelines are 4 to 6 ft./sec. for suction and 6 to 10 ft./sec. for discharge.
• Pressure drop across permanent suction strainers needs to be considered when calculating pump inlet suction pressure.
• Tee branches and valve stems must be installed perpendicular to the pipe centerline. Installing them parallel is incorrect.
NPSH: The pump must have enough positive suction head to prevent cavitation. The NPSH available (NPSHa) must be greater than the NPSH required (NPSHr). To locate NPSHr information, refer to the pump’s performance curve.
For submerged suction, the inlet must be located deep enough to prevent vortexing. If needed to prevent the formation of a vortex, provide vortex breakers in the suction vessel.
The suction piping must be free of all air pockets. An eccentric reducer may be used to reduce the chances of air pockets forming if joining different sizes of suction piping.
NOTICE: Never control the pump flow by throttling a valve in the suction line. The only function of the suction valve is to isolate the pump from the system for maintenance.
A straight length of suction piping (at least five times the diameter of the pipe) is recommended directly in front of the suction flange. Never insert an elbow directly in front of the suction flange.
All elbows in suction piping should be long radius.
When operating from the same supply source, separate suction lines are recommended.
Suction strainers need to have a total free area of at least three times the suction piping area.
A straight length of suction piping at least five times the diameter of the pipe is recommended directly in front of the suction flange.
Problems may occur if the elbow bolts directly to the pump’s suction. The liquid tends to follow the longer radius, creating a void or reverse flow along the shorter radius, which starves part of the impeller.
5 DIAMETERS
Piping for elevated source should be in one plane. A straight length of suction piping at least five times the diameter of the pipe is recommended directly in front of the suction flange.
5 DIAMETERS
NOT RECOMMENDED
Avoid situations where there are many elbows in many planes.
NOT RECOMMENDED
REDUCERS:
• Suction piping is usually no more than one diameter larger than pump suction nozzle.
6
SUCTION
SUCTION
3500 SERIES / MODEL 3550
ORIENTATION:
• For suction above centerline: Eccentric – Flat side on bottom. Concentric.
Install an isolation valve to prevent the pump, at start-up, from running in excess of the pump curve by throttling while the system is being filled. The isolation valve is also used to isolate the pump for maintenance.
Undersized valves can cause excessive flow restriction. Install reducers between the check valve and the pump to prevent this.
If system demands require long periods of near shut-off operation, a recirculation line should be installed. Install the recirculation line off the discharge line, which returns to the supply reservoir below the liquid level. Install a valve or orifice in the bypass line to regulate flow. An automatic valve may be needed to regulate flow or to prevent excessive stops and starts. Automatic valves are needed especially when using large motors.
Quick acting valves should be installed to protect the pump from surges and water hammer in the system.
MECHANICAL SEAL:
• For suction below centerline: Eccentric – Flat side on top.
Concentric not recommended.
PIPING INSTALLATION:
• To minimize friction losses, piping runs should be as short as possible.
• Flanges should be concentric allowing the bolts to be inserted into the flange holes with finger pressure only. Do not use spud wrenches or come-a-longs to align the flange holes.
• To prevent excessive nozzle loads, piping should be anchored, restrained and supported separate from the pump, near the suction and discharge.
• Limit parallelism of the flange gasket surfaces to .002"/in. of normal pipe size with a maximum parallelism of .03".
EXAMPLE USING 4" PIPE:
4 x .002" = .008" max.
• 3" and under pipe sizes are flexible. These allow a .008" maximum out-of-parallelism without causing shaft alignment problems.
• Be sure to have the pump grouted and aligned prior to connecting the last 20' of piping to the pump suction and discharge.
• To monitor movement when the piping is bolted up, install dial indicators from the driver to the pump. The maximum acceptable movement is .002".
• Tighten flange bolt to 2/3 torque using crisscross pattern for first pass. Finish the final bolt torque in a clockwise pattern.
DISCHARGE PIPING: Install a check valve between the isolation valve and the pump to protect the pump from running backward when it is shut down.
Warning:
Never operate the pump without liquid supplied to the mechanical seal. Running the mechanical seal dry, even for short periods, can cause seal damage and/or failure. Physical injury can occur if mechanical seal fails.
The mechanical seal is flushed and cooled by the pumped fluid or an external source. If using an external source, the media must be clean, solid-free and compatible with the pumped fluid.
Quench, vent and/or drain ports are available as seal options.
Make proper connections when required by the application.
Always follow all seal instructions.
BEFORE PUMP OPERATION:
Confirm that:
• All set screws are tightened to the shaft.
• All centering clips are removed.
• All required mechanical seal auxiliary systems are properly installed and connected.
Because seal life is dependent on a variety of factors
(cleanliness of process, operating conditions, etc.), it is difficult to predict seal life for a given application.
LUBRICATION:
BEARING OIL LUBE: Fill pump bearing frame with high quality, antifoaming turbine oil. Oil should contain rust and oxidation inhibitors.
SUGGESTED OILS:
Mobil DTE Heavy Medium
Royal Purple Synfilm IOS VG 68 (synthetic)
Shell Turbo NO. T68
Shell Omala 68
Texaco Regal R + O NO. 68
7
Change oil every 12 months. Oil should be changed more frequently under severe environmental conditions (dust, moisture, corrosive atmospheres, etc.).
PROPERTIES OF LUBRICATING OIL:
3500 SERIES / MODEL 3550
ISO GRADE VG...................................................................... 68
Approximate SSU at 100°F (40°C) ....................................... 300
300 Kinematic Viscosity at 100°F (40°C)(cSt) ....................... 68
BEARING FRAME: Use the optional cooling coil for water cooling of the bearing frame. The cooling coil is required only when the pumped media temperature surpasses 400°F (204°C) at 1800 RPM or 300°F (149°C) at 3600 RPM. Under these conditions, ambient temperature water at 1–3 gallons/minute
(.23 to .68 m 3 /hr.) is required for appropriate cooling of the oil.
To keep the oil temperature below the maximum recommended, higher flows may be necessary.
OIL LEVEL: The oil level in the bearing frame should be one-half (1/2) of the way up the oil sight glass when the unit is not operating.
BEARING FRAME OIL VOLUMES:
Turn on the cooling water before allowing the hot process fluid to enter the pump.
SEAL CHAMBER: Water jacketed seal chambers are available. Requirements for the jacket are based on the type of mechanical seal and selection of elastomers.
Bearing Frame Oil Capacity
Frame Pints (ml)
S 1.0 (473)
M
L
XL
2.6 (1,230)
3.0 (1,420)
7.4 (3,502)
Ambient temperature water at 2–3 gallons/minute (.45 to .68 m /hour) is required for appropriate cooling of the seal chamber when a jacket is installed.
A jacket is recommended for any application over 350°F
(177°C). Consult the factory for specific recommendations.
BEARING GREASE LUBE: Choose premium quality lithium grease. The grease should have an NLGI 2 or 3 consistency and a base oil viscosity of 68 centistokes minimum at 40°C. Pregrease the bearings after assembly onto the shaft when reassembling the pump. Pack the bearings full with grease; pack the bearing housing adjacent to the bearings onethird (1/3) to one-half (1/2) full.
SEAL FLUSH: The seals may be cooled and/or heated 1) from an external source or 2) by passing pump discharge fluid through a heat exchanger and then into the seal flush connection. A double seal may use cooled/heated barrier fluid from an external source or convection system.
Always follow all required seal operating instructions as listed in the seal instruction booklet.
OPERATION:
START-UP INSPECTION:
NOTICE: Never mix greases of different consistencies.
SUGGESTED GREASES:
Chesterton #615
SKF LGMT2/LGMT3
REGREASING INTERVALS: For back-to-back angular contact, single and double row bearings, add several shots of grease from a grease gun at the following intervals:
RPM
1180 RPM
1750 RPM
3550 RPM
Hourly Interval
5000 hours
4000 hours
1250 hours
1. Check Installation. Examine the entire pump package for proper alignment. Confirm that all auxiliary systems are connected and ready for use.
2. Check Rotation Direction.
NOTICE: Improper rotation direction will damage the pump.
Bearings need regreasing more frequently at bearing temperatures above 150°F (66°C). Halve greasing intervals for every 27°F (15°C) increase. Grease temperature should not exceed 185°F (85°C). Replace the grease completely at every third regreasing interval or at least once a year minimum.
NOTICE: Overgreasing is the most common cause of bearing overheating and contributes to premature bearing failure.
COUPLING LUBRICATION: Consult the coupling manufacturer’s instructions for lubrication information.
TEMPERATURE CONTROL:
NOTICE: Normal operating oil temperature should be below 160°F (71°C) and should NEVER surpass 180°F
(82°C).
Warning:
Lock out driver to prevent accidental start-up and physical injury.
The coupling must be totally disconnected from the pump and driver when checking for proper rotation direction.
Operate the driver independently to check for proper rotation. The pump rotation should be clockwise when viewed from the coupling end. The rotation direction is distinguished by an arrow on the front of the casing.
3. Check Impeller Clearance.
NOTICE: Setting impeller clearance is crucial for maintaining maximum pump efficiency. Be sure to compensate for additional thermal growth in high temperature applications. Consult Appendix I (page 22) of the manual to set impeller clearance.
Set impeller clearance.
8
a. When making adjustments, unseat the mechanical seal from the shaft.
3500 SERIES / MODEL 3550
START-UP:
b. Check total clearance. Confirm that it follows the given instructions.
NOTICE: Before start-up, confirm that the shaft turns freely by hand (clockwise when facing the coupling end).
c. Set the proper operating clearance on the suction side of the impeller.
Increase the clearance on the suction side of the impeller if the pumpage temperature exceeds 100°F (38°C). Consult
Appendix I Table I of the manual for proper instructions.
Open the suction valve completely. Start the pump with the discharge valve open approximately 20% before gradually opening the valve until reaching design flow point. The discharge valve should be adjusted to achieve proper process flow, operating as close to the BEP as possible. The suction line should not be throttled or restricted at all during the operation.
4. Check Rotating Element. To confirm a free-rotating element, turn the shaft by hand several times (there will be a degree of resistance due to the bearings and the mechanical seal). Do not attempt to operate the pump if any rubbing noise occurs during this process. Instead, readjust the impeller clearance as outlined in Appendix I, then reset the mechanical seal according to its instructions.
PUMP PERFORMANCE: Once started, confirm that the pump is running at or close to the operating point on the pump performance curve. Throttle the discharge valve if the pump is overloading the motor or delivering too much flow. A restriction orifice at the pump discharge may be necessary to control pump capacity.
Monitor all the flows and pressures to the auxiliary components and adjust accordingly.
5. Check Lubrication. Inspect the pump, motor and coupling for proper lubrication.
Check the mechanical seal and all other connections for potential leakage. Tighten where necessary.
AUXILIARIES START-UP: The unit’s auxiliary components must be turned on where applicable before priming and starting the pump. Do not start the pump / motor until all the auxiliary systems are fully operating.
BEARING FRAME COOLING: Turn on the water to the cooling coil in the bottom of the oil sump if applicable. For proper flow requirements, consult page 8 of the manual.
Shut down the pump when it has run for one hour and is at maximum operating temperature. Then, turn the shaft by hand
(in the direction of the rotation arrow) to establish that the rotating element is not binding and the impeller is not rubbing.
Also check the shaft alignment. Consult page 5 for coupling alignment.
MECHANICAL SEAL: Turn on the flush, quench or barrier fluid to the mechanical seal if applicable. Regulate pressure and flow according to the seal manufacturer's installation instructions. Turn on the heating/cooling fluid if the seal flush includes a heat exchanger.
SEAL CHAMBER JACKET: Turn on the water to the cooling jacket attached to the seal chamber. For proper flow requirements, consult page 8 of the manual.
Danger:
Never operate the pump below minimum rated flow and/or with the discharge valve closed. These operating conditions could cause extreme temperature rise in the pump and an explosive hazard. Also, premature failure can result due to high radial loads and excess vibration.
SHUTDOWN:
PRIMING:
To shut down the pump:
The pump is now ready to be primed.
1. Close the pump discharge valve.
1. Turn off the pump and de-energize the motor. Be sure motor is locked out before attempting to work on the pump.
2. Open the pump suction valve.
Warning:
Never operate the pump dry. It is important that the pump never be subjected to thermal shock. The liquid must be allowed to enter the pump casing slowly. A centrifugal pump should never be started until all parts have been gradually brought to the ultimate intended pump temperature.
3. Confirm that all vent and/or ejector connections are closed after priming.
Warning:
Lock out driver to prevent accidental start-up and physical injury.
2. Close the discharge valve and the suction valve.
3. Drain the pump casing.
4. Turn off all auxiliary components in the reverse order from start-up.
5. To prevent damage from freezing in cold weather, the entire pump (including all auxiliary components) should be completely drained.
9
Tag valves as standard practice.
MAINTENANCE:
3500 SERIES / MODEL 3550
• Screwdriver
• Snap-Ring Pliers
• Torque Wrench with Sockets
• Wrenches Warning:
When handling hazardous and/or toxic fluids, use personal protection equipment to avoid personal injury. Pumpage must be handled and disposed of in accordance with applicable environmental regulation.
DISASSEMBLY:
Warning:
Pump components can be heavy. Proper methods of lifting must be employed to avoid physical injury and/or equipment damage. Steel toed shoes must be worn at all times.
DISASSEMBLY:
CAUTION
Always use a lifting device capable of supporting the full weight of the pump components or assemblies.
Warning:
Personal protective equipment must be worn if there is a potential for handling hazardous or toxic materials. Fluid must be handled and disposed of in accordance with local and national regulations. Pump must be isolated by closing suction and discharge valves before working on the pump.
Warning:
The pump may handle hazardous and/or toxic fluids. Proper personal protective equipment should be worn. Precautions must be taken to prevent physical injury. Pumpage must be handled and disposed of in conformance with applicable environmental regulations.
NOTE: Ensure all replacement parts are available before disassembling the pump for overhaul.
Warning:
Lock out power to the driver before working on the pump.
Failure to properly lock out driver could result in accidental start, causing personal injury.
Warning:
Lock out power supply to driver / motor to prevent accidental start-up and physical injury.
1. Stop flow to and from pump. Be sure all valves are closed.
CAUTION
Do not adjust or disassemble any pressure containing component or shaft seal prior to depressurizing the primary and auxiliary fluid systems. This will ensure that no hazardous or high pressure fluid is ejected that may cause personal injury or equipment damage.
Warning:
Operator must be aware of pumpage and safety precautions to prevent physical injury.
2. Drain liquid from piping. If necessary, flush pump.
DISASSEMBLY & ASSEMBLY:
Required Tools .................................................................page 10
Disassembly ............................................................pages 10–12
Inspections ...............................................................pages 12–13
Assembly..................................................................pages 13–17
REQUIRED TOOLS:
• Allen Wrenches
• Bearing Puller
• Brass Drift Punch
• Cleaning Agents
• Dial Indicator
• Feeler Gauges
• Hydraulic Press
• Induction Bearing Heater
• Leveling Blocks
• Lifting Sling
• Micrometer
• Rubber Mallet
Warning:
Allow all system and pump components to cool before handling them to prevent physical injury.
3. Remove piping and tubing.
4. Remove coupling guard. Consult the Coupling Guard
Installation and Disassembly section in Appendix II (page
22–23).
5. Disconnect coupling.
6. Remove pump endplate for coupling guard.
7. Drain oil from bearing frame (if oil lubricated). To drain:
• Remove bearing frame drain plug (408A or H).
• After oil is drained, replace plug.
• If equipped, remove oil reservoir.
10
9. Remove bearing frame foot hold-down bolts and casing bolts (370).
3500 SERIES / MODEL 3550
8. Use frame adapter (108) or frame (228) for placing hoisting strap.
3. Quickly turn impeller counterclockwise (as viewed from impeller end of shaft), impacting wrench handle on the workbench or solid block until impeller loosens.
4. Remove impeller O-ring (412) and discard. (Replace with new O-ring during reassembly.)
XL model:
1. Perform steps 1 – 3 as listed above.
Warning:
Never apply heat to remove parts. Use of heat may cause an explosion due to trapped fluid, resulting in severe physical injury and property damage.
10. Tighten jack screws (418) evenly then remove back pull-out assembly from casing (100).
2. If impeller cannot be loosened after several attempts:
• Place a socket wrench over cast nut on impeller hub.
• Turn impeller counterclockwise (as viewed from impeller end of shaft).
• Use work surface or a block to rest the impeller wrench on.
• Secure power end to work surface.
NOTE: If adapter to casing joint is excessively corroded, penetrating oil can be used.
NOTE: Remove and then mark shims from under frame foot. Save for reassembly.
3. Remove impeller O-ring (412) and discard. (Replace with new O-ring during reassembly.)
NOTE: Clamp frame foot (241) to workbench when using this method to remove impeller.
Warning:
Never remove the back pull-out assembly unassisted.
Physical injury can occur.
11. Remove casing gasket (351). This gasket should be replaced with a new one when reassembled.
12. Remove jack screws (418).
NOTE: Due to binders and adhesives in the gasket material, casing gasket (351) may partially adhere to casing. Clean all gasket surfaces.
13. Be sure to place back pull-out assembly on a clean work surface to avoid contamination.
14. Secure frame adapter (108 / 228) to work surface.
15. Carefully remove the coupling hub.
IMPELLER REMOVAL:
NOTE FOR ALL MODELS: If previous methods do not successfully remove impeller, complete the following steps:
• Cut shaft between gland and frame.
• Remove impeller, stuffing box cover, gland, sleeve and shaft end as one unit.
• Do not use heat.
SEAL CHAMBER COVER (MECHANICAL SEAL)
REMOVAL:
1. Remove the following components in the order listed below:
• Gland stud nuts (355)
• Seal chamber stud nuts (370H)
• Seal chamber (184)
• Shaft sleeve (126) (If used)
NOTE: Mechanical seal is attached to sleeve (126).
Rotary portion of seal must be removed from sleeve by loosening set screws and sliding it off the sleeve. Consult mechanical seal instructions.
Warning:
Never apply heat to remove an impeller. The use of heat may cause an explosion due to trapped fluid, resulting in severe physical injury and property damage.
Warning:
Wear heavy work gloves when handling impellers (101) as sharp edges may cause physical injury.
S, M, L models:
1. Slide shaft wrench over shaft (122) and key.
2. Rotate impeller clockwise (as viewed from impeller end of shaft), raising wrench off the work surface.
2. Remove gland (250) with stationary seat and O-ring (360Q).
NOTE: Do not damage stationary portion of mechanical seal. Stationary portion is seated in the gland bore.
STUFFING BOX COVER (PACKED BOX) REMOVAL:
Remove the following components in the order listed below:
• Gland stud nuts (355) and gland (107)
• Stuffing box cover stud nuts (370H) and stuffing box cover
(184)
• Shaft sleeve (126)
• Packing (106) and lantern ring (105) from stuffing box cover (184) (No lantern ring is provided with selflubricating graphite packing)
11
FRAME ADAPTER REMOVAL – M, L, XL:
3500 SERIES / MODEL 3550
Remove the following components in the order listed below:
3. Finish disassembly by removing outboard labyrinth seal
(332) from bearing housing (134). If necessary, remove
O-rings (497F, 497G).
• Dowel pins (469B) and bolts (370B)
• Frame adapter (108)
• Gasket (360D) (Discard and replace with new gasket during reassembly)
INBOARD LABYRINTH OIL SEAL (333) REMOVAL:
POWER END (XL MODEL) DISASSEMBLY:
1. Remove bearing frame foot-to-frame bolts (370F) and frame foot (241).
NOTE: It is an O-ring fit into bearing frame (228) for STX, frame adapter (108) for M, L & XL models. If necessary, remove O-rings (497H, 497J).
Remove the following components in the order listed below:
2. Remove clamp screws (370C). Back off jam nuts (423).
Tighten jack screws (370D) evenly as this will start bearing housing (134) out of bearing frame (228).
3. Remove the following components in the order listed below:
• Shaft assembly from bearing frame (228)
• Jack screws (370D) with nuts (423)
• Bearing housing O-ring (496)
• Inboard bearing (168)
• Jack screws (370D) with nuts (423)
• Bearing housing O-ring (496)
• Outboard bearing housing retaining snap ring (361A)
(Snap ring cannot be removed from shaft until bearings are removed)
• Bearing housing (134) from shaft (122) with bearings (112,
168)
• Outboard labyrinth seal (332) from bearing housing (134)
• O-rings (497F, 497G) if necessary
• Bearing locknut (136) and bearing lock washer (382)
• Inboard bearing (168)
• Outboard bearing (112)
NOTE: Use force on inner race ONLY when pressing bearings off shaft.
NOTE: Save bearings for inspection.
POWER END (L MODEL) DISASSEMBLY:
NOTE: Use force on inner race ONLY when pressing bearings off shaft.
NOTE: Save bearings for inspection.
4. Finish disassembly by removing the following components in this order:
• Bolts (371C), bearing end cover (109) and gasket (360)
• Outboard labyrinth seal (332) from end cover (109).
• O-rings (497F, 497G) (if necessary)
• Bearing housing (134) from shaft (122) with bearing
(112)
• Bearing locknut (136) and bearing lock washer (382)
• Outboard bearing (112)
NOTE: Use force on inner race ONLY when pressing bearings off shaft.
1. Remove clamp screws (370C). Back off jam nuts (423).
Tighten jack screws (370D) evenly as this will start bearing housing (134) out of bearing frame (228).
2. Remove the following components in the order listed below:
NOTE: Save bearings for inspection.
BEARING FRAME (ALL MODELS) DISASSEMBLY:
• Shaft assembly from bearing frame (228)
• Jack screws (370) with nuts (423)
• Clamp ring screws (236A) a. Separate clamp ring (253B) from bearing housing
(134) b. Clamp ring cannot be removed from shaft until bearings are removed
• Bearing housing (134) from shaft (122) with bearings
(112, 168)
• Bearing housing O-ring (496)
• Inboard bearing (168)
• Bearing locknut (136) and bearing lock washer (382)
• Outboard bearings (112)
• Clamp ring (253B)
NOTE: Use force on inner race ONLY when pressing bearings off shaft.
NOTE: Save bearings for inspection. Do not reuse bearings.
NOTE: Unless damaged in any way, do not remove oil flinger (248).
1. Remove the following components from the bearing frame
(228) in the order listed below:
• Oil fill plug (228)
• Oil drain plug (408A)
• Sight glass (319)
• Sight oilier plug (408J)
• Four (4) oil mist/grease connection plugs (408H)
• Oil cooler inlet and outlet plugs (408L, 408M) or oil cooler
2. MTX, LTX: Remove bearing frame foot-to-frame bolts
(370F) and frame foot (241).
INSPECTIONS: Prior to reassembly, pump parts must meet the following inspection criteria to guarantee the pump will operate properly. Replace any part that does not pass inspection.
NOTE: Clean parts in solvent to remove oil, grease or dirt while protecting machined surfaces from damage.
CASING: Check casing (100) for cracks, excessive wear and pitting. Repair or replace casing (100) if it exceeds the following criteria:
12
3500 SERIES / MODEL 3550
• Localized wear or grooving greater than 1/8" (3.2mm) deep
• Pitting greater than 1/8" (3.2mm) deep
• Check case gasket seat surface for deformities or irregularities
REASSEMBLY:
Rotating Element and Bearing Frame Assembly
S, M Models
IMPELLER: Repair or replace the following impeller (101) components if they exceed the following criteria:
• Impeller vanes grooved deeper than 1/16" (1.6mm) or if worn evenly more than 1/32" (0.8mm)
• Pump-out vanes if worn more than 1/32" (0.8mm)
• Check leading and trailing edges of vanes for cracking, pitting, erosion and/or corrosion.
FRAME ADAPTER: Replace frame adapter (108) if any cracking or excessive corrosion damage is present.
Confirm that the gasket surface is clean.
SHAFT AND SLEEVE: Replace shaft (122) if any bearing fits are outside the tolerance listed in Appendix III (page 23).
Replace shaft (122) and sleeve (126) if the surface shows any sign of grooves or pitting.
BEARING FRAME: Check bearing frame (228) and frame foot (241) for cracks. Inspect frame inside surfaces for rust, scale or other debris. Remove all loose and foreign material.
NOTE: Apply thread sealant to clean pipe threads and fittings.
1. Install the following components into the bearing frame
(228) in the order listed below:
• Oil fill plug (228)
• Oil drain plug (408A)
• Sight window (319)
• Sight oilier plug (408J)
• Four oil mist connection plugs (408H) or grease fittings
(193) and relief plugs (228)
• Oil cooler inlet and outlet plugs or oil cooler (408L,
408M)
2. Hand-tighten bearing frame foot (241) with bolts (370F).
NOTE: Outboard regreaseable bearing has a single shield and is installed with shield toward impeller.
NOTE: The recommended bearing installation method is to use an induction heater that heats as well as demagnetizes the bearings.
Confirm that all lubrication passages are clear.
Inspect frame for corrosion or pitting if it has been exposed to pumpage.
Consult Appendix III (page 23) when inspecting inboard bearing bore.
BEARINGS: Check ball bearings (112, 168) for contamination and/or damage. Bearing conditions will provide information on operating conditions in bearing frame.
Take note of lubricant condition and residue. Oil analysis is helpful. Investigate bearing damage to determine cause of damage. Immediately correct cause of damage if it is not a result of normal wear.
NEVER REUSE BEARINGS.
BEARING HOUSING: Consult Appendix III (page 23) when inspecting bearing housing (134) bore. Replace if dimensions surpass those listed in Appendix III.
Check for cracking and pitting.
• S, M Models: Check for cracks in snap ring groove. It must not be cracked.
• L Model: Check that grooves and holes are clear.
• XL Model: Be sure gasket surface is clean.
LABYRINTH SEALS: Replace labyrinth seal (332, 333)
O-rings if any cuts or cracks are present.
Warning:
Wear insulated gloves when using a bearing heater.
Bearings will get hot and can cause physical injury.
3. Install outboard bearing (112) on shaft (122).
4. Place lock washer (382) with tang in keyway of shaft (122).
5. Thread locknut (136) onto shaft (122) and tighten locknut until snug. Bend any tang of lock washer into a slot of locknut.
NOTE: If necessary, tighten locknut to align the closest tab of lock washer with slot on locknut.
6. Place bearing retaining ring (361A) over shaft (122), flat side facing bearing.
7. Install inboard bearing (168) on shaft (122).
NOTE: Inboard regreaseable bearing has a single shield and is installed with shield away from impeller.
NOTE: The recommended bearing installation method is to use an induction heater that heats as well as demagnetizes the bearings.
Warning:
Wear insulated gloves when using a bearing heater.
Bearings will get hot and can cause physical injury.
NOTE: Lubricate internal surfaces of bearings.
13
8. Install new O-ring (496).
3500 SERIES / MODEL 3550
4. Note orientation when placing bearing clamp ring (253B) over shaft (122).
9. Use oil to coat the outside of outboard bearing (112) and bearing housing (134) bore.
5. Install the outboard bearings (112) on shaft (122).
10. Place bearing housing (134) onto shaft/bearing assembly.
NOTE: DO NOT force assembly together.
CAUTION
The L model uses duplex bearings mounted back-toback. Make sure orientation of the bearings is correct.
11. Place retaining ring (361A) into groove in bearing housing bore (134). Be sure shaft is free turning.
NOTE: For unobstructed oil flow, the space between the ends of retaining ring should be located in the oil return groove.
NOTE: The recommended bearing installation method is to use an induction heater that heats as well as demagnetizes the bearings.
12. Install outboard labyrinth oil seal (332) into bearing housing
(134) (it is an O-ring fit). Position the labyrinth seal drain slots at the bottom (6 o’clock) position.
Warning:
Wear insulated gloves when using a bearing heater.
Bearings will get hot and can cause physical injury.
NOTE: Consult Appendix V (page 24) for more detailed labyrinth seal installation instructions.
6. Place lock washer (382) with tang of lock washer in keyway, on shaft (122).
NOTE: Keyway edges must be free of burrs.
NOTE: To protect O-rings, cover keyway lengthwise with a piece of electrical tape before installing labyrinth seal.
7. Thread locknut (136) onto shaft (122) and tighten locknut until snug. Bend any tang of lock washer (382) into a slot of locknut.
13. Use oil to coat outside of bearing housing (134) and all internal surfaces of bearing frame (228).
NOTE: If necessary, tighten locknut to align the closest tab of lock washer with slot on locknut.
8. Install the inboard bearing (168) on shaft (122).
14. Allowing approximately .125" (3.175mm) clearance between the face of bearing housing and bearing frame, install shaft assembly into frame (228). Check shaft for free turning.
NOTE: Inboard regreaseable bearing has a single shield and is installed with shield away from impeller.
15. Hand-tighten clamping bolts (370C) into bearing housing
(134).
NOTE: The recommended bearing installation method is to use an induction heater that heats as well as demagnetizes the bearings.
16. Hand-tighten jacking bolts (370D) with locking nuts (423) into housing (134).
L MODEL:
NOTE: Apply thread sealant to clean pipe threads and fittings.
Warning:
Wear insulated gloves when using a bearing heater.
Bearings will get hot and can cause physical injury.
NOTE: Lubricate internal surfaces of bearings.
1. Install the following components into the bearing frame
(228) in the order listed below: 9. Use oil to coat outside of outboard bearing (112) and bearing housing (134) bore.
• Oil fill plug (228)
• Oil drain plug (408A)
• Sight window (319)
• Sight oilier plug (408J)
• Four oil mist connection plugs (408H) or grease fittings
(193) and relief plugs (228)
• Oil cooler inlet and outlet plugs or oil cooler (408L,
408M)
2. Hand-tighten bearing frame foot (241) with bolts (370F).
10. Place bearing housing (134) onto shaft/bearing assembly.
NOTE: DO NOT force assembly together.
11. Install clamp ring bolts (236A). Check shaft for free turning.
Consult Appendix VI (page 25) for bolt torque values.
CAUTION
Tighten clamp ring bolts (236A) in a crisscross pattern.
3. Install oil flinger (248) on shaft (122) (if removed).
12. Install new O-ring (496).
NOTE: Oil flinger is a press-fit onto shaft. Use a propersized driver to prevent damage to oil flinger.
13. Install outboard labyrinth oil seal (332) into bearing housing
(134) (it is an O-ring fit). Position the labyrinth seal drain slots at the bottom (6 o’clock) position.
14
3500 SERIES / MODEL 3550
NOTE: Consult Appendix V (page 24) for detailed labyrinth seal installation instructions.
NOTE: If necessary, tighten locknut to align the closest tab of lock washer with slot on locknut.
NOTE: Keyway edges must be free of burrs.
NOTE: To protect O-rings, cover keyway lengthwise with a piece of electrical tape before installing labyrinth seal.
14. Use oil to coat outside of bearing housing (134) and all internal surfaces of bearing frame (228).
5. Using oil, coat outside of outboard bearing (112) and bore of bearing housing (134).
6. Install the bearing housing (134) onto shaft/bearing assembly.
NOTE: DO NOT force assembly together.
7. Install gasket (360), end cover (109) and bolts (371C). For bolt torque values, consult Appendix IV (page 24). Check shaft for free turning.
15. Allowing approximately .125" (3.175mm) clearance between the face of bearing housing and bearing frame, install shaft assembly into frame (228). Check shaft for free turning.
16. Hand-tighten clamping bolts (370C) into bearing housing
(134).
17. Hand-tighten jacking bolts (370D) with locking nuts (423) into housing (134).
XL MODEL:
NOTE: Apply thread sealant to clean pipe threads and fittings.
1. Install the following components into the bearing frame
(228) in the order listed below:
• Oil fill plug (113)
• Oil drain plug (408A)
• Sight glass (319)
• Sight oilier plug (408J)
• Four oil mist connection plugs (408H) or grease fittings
(193) and relief plugs (228)
• Oil cooler inlet and outlet plugs or oil cooler (408L,
408M)
2. Place the outboard bearing (112) on shaft (122).
NOTE: Outboard regreaseable bearing has a single shield and is installed with shield toward impeller.
NOTE: The recommended bearing installation method is to use an induction heater that heats as well as demagnetizes the bearings.
8. Place the inboard bearing (168) on shaft (122).
NOTE: Inboard regreaseable bearing has a single shield and is installed with shield away from impeller.
NOTE: The recommended bearing installation method is to use an induction heater that heats as well as demagnetizes the bearings.
Warning:
Wear insulated gloves when using a bearing heater.
Bearings will get hot and can cause physical injury.
NOTE: Lubricate internal surfaces of bearings.
9. Install new O-ring (496).
10. Install outboard labyrinth oil seal (332) into end cover (109)
(it is an O-ring fit). Position the labyrinth seal drain slots at the bottom (6 o’clock) position.
NOTE: Consult Appendix V (page 24) for detailed labyrinth seal installation instructions.
NOTE: Keyway edges must be free of burrs.
NOTE: To protect O-rings, cover keyway lengthwise with a piece of electrical tape before installing labyrinth seal.
11. Use oil to coat outside of bearing housing (134) and all internal surfaces of bearing frame (228).
Warning:
Wear insulated gloves when using a bearing heater.
Bearings will get hot and can cause physical injury.
Warning:
Shaft (122) may be heavy. Use care when handling.
12. Allowing approximately .125" (3.175mm) clearance between the face of bearing housing and bearing frame, install shaft assembly into frame (228). Check shaft for free turning.
13. Install and hand-tighten the following components in the order listed below:
3. Place lock washer (382) with tang of lock washer in keyway, on shaft (122).
4. Thread locknut (136) onto shaft (122) and tighten locknut until snug. Bend any tang of lock washer (382) into a slot of locknut.
• Clamping bolts (370C) into bearing housing (134)
• Jacking bolts (370D) with locking nuts (423) into housing
(134)
• Bearing frame foot (241) with bolts (370F)
ALL MODELS:
1. Support frame assembly horizontally.
15
3500 SERIES / MODEL 3550
2. Check shaft end play by moving shaft forward and backward by hand, taking note of indicator movement. If total indicator reading is greater than the values listed in
Appendix IV (page 24), disassemble and determine cause.
shaft wrench (counterclockwise as viewed from impeller end of shaft) off bench then slam it down (clockwise as viewed from impeller end of shaft). A few sharp raps will properly tighten impeller (101).
3. Check shaft/sleeve run-out by completing the following steps:
• Put on shaft sleeve (126) (if used) and thread on impeller, hand-tight.
• Rotate shaft 360 degrees. If total indicator reading is greater than .002", disassemble and determine cause.
• Remove impeller and shaft sleeve.
6. Loosen clamp bolts (370C) and jacking bolts (370D). Using a feeler gauge, measure gap between impeller (101) and seal chamber/stuffing box cover (184). Tighten clamp bolts
(370C), jacking bolts (370D) and locking nuts (423) when
.030" (.76mm) clearance is reached.
NOTE: The above steps approximate the impeller position when set at .015" (.38mm) from casing. Make final impeller adjustment after installation into casing.
4. Check frame face run-out by rotating shaft so indicator rides along the fit for 360 degrees. If total indicator reading is greater than .001" (.025mm), disassemble and determine the cause.
5. Place manila colored gasket (360) on clean frame (228).
NOTE: Dowel pins (469B) may be started in their holes to hold the gasket in place. This gasket must be installed only one way.
6. Install frame adapter (108) onto frame assembly by aligning bolt holes and dowel locations with those on frame.
7. Install dowel pins (469B) and bolts (370B). Tighten bolts in a crisscross pattern according to torque specifications found in Appendix IV (page 24).
8. Check adapter fits by rotating shaft through 360 degrees.
If total indicator reading is greater than .005" (.13mm), determine the cause and correct before continuing.
7. Inspect impeller (101) run-out by checking vane tip to vane tip. Total indicator reading is to be less than .005" (.13mm).
If reading is in excess of this, determine the cause and correct before continuing.
8. Blue the shaft sleeve (126) or shaft (122) if no sleeve is used. Draw a mark at gland gasket face of seal chamber/ stuffing box cover (184). This will be the datum for installation of mechanical seal.
NOTE: The shaft or sleeve does not need to be marked if installing a cartridge mechanical seal as this seal is selfsetting.
9. Remove impeller (101) and shaft sleeve (126) (if used).
10. Remove seal chamber cover/back plate (184).
FOR INSIDE MOUNTED SEALS:
11. Install stationary seat into gland (107). Be sure to follow the seal manufacturer’s instructions.
9. Install inboard labyrinth oil seal (333) into adapter (108)
/bearing frame (228) (it is an O-ring fit). Position the labyrinth seal drain slots at the bottom (6 o’clock) position.
NOTE: Consult Appendix V (page 24) for detailed labyrinth seal installation instructions.
PUMPS WITH MECHANICAL SEALS:
12. Position gland (107) with stationary seat over shaft and up to the adapter face.
13. Install mechanical seal on shaft (122) or shaft sleeve (126) following the seal manufacturer’s instructions. Install shaft sleeve (126) if used (with seal).
1. Install seal chamber cover/back plate (184) with nuts
(370H).
2. Inspect seal chamber cover run-out by rotating indicator through 360 degrees. If total indicator reading is greater than .005" (.13mm), determine the cause and correct before continuing.
3. Install shaft sleeve (126) (if used).
NOTE: Sleeve must be fully seated.
NOTE: Apply anti-galling compound to the sleeve bore for easier disassembly.
14. Install the seal chamber cover (184) with nuts (370H).
Warning:
Wear a heavy set of work gloves when handling impeller
(101) as sharp edges may cause physical injury.
Warning:
Wear a heavy set of work gloves when handling impeller
(101) as sharp edges may cause physical injury.
4. S, M, L Models: Install impeller (101) using O-ring (412).
5. Place shaft wrench and coupling key on shaft. When impeller (101) makes firm contact with sleeve (126), raise
15. Install impeller (101) with new O-ring (412). Place shaft wrench and coupling key on shaft. When impeller (101) makes firm contact with sleeve (126), raise shaft wrench
(counterclockwise as viewed from impeller end of shaft) off bench then slam it down (clockwise as viewed from impeller end of shaft). A few sharp raps will properly tighten impeller (101).
NOTE: Impeller must be properly balanced.
16. Install the gland (107) using nuts (355).
16
3500 SERIES / MODEL 3550
FOR OUTSIDE MOUNTED SEALS:
11. Install the mechanical seal on shaft (122) or, if applicable, sleeve (126) following the seal manufacturer’s instructions.
Install sleeve with seal if applicable.
12. Move gland. Move stationary seat, with gaskets, on shaft or sleeve.
13. Install seal chamber or back plate (184) with hex nuts
(370H). Confirm that gland studs line up with holes in gland.
7. Install the packing and gland.
REINSTALL BACK PULL-OUT ASSEMBLY
ALL MODELS (S, M, L & XL):
Warning:
Back pull-out assembly weighs more than 50 lbs. DO NOT handle unassisted as physical injury may occur.
14. Install impeller (101) with new O-ring (412). Place shaft wrench and coupling key on shaft. When impeller makes firm contact with sleeve (126), raise shaft wrench
(counterclockwise as viewed from impeller end of shaft) off bench then slam it down (clockwise as viewed from impeller end of shaft). A few sharp raps will properly tighten impeller.
1. Install casing gasket (351) in place on seal chamber/stuffing box cover. Be sure all surfaces are clean.
2. Release clamping bolts (370C), jacking bolts (370D) from bearing housing.
3. Position the back pull-out assembly in casing.
NOTE: Impeller must be properly balanced.
15. Install the gland (107) using hex nuts (355).
4. Install and hand-tighten casing bolts (370). Consult
Appendix IV regarding proper torque values for casing bolts. Install casing jack screws (418) snug tight.
PUMPS WITH PACKING:
1. Install the stuffing box cover (184) using nuts (370H).
NOTE: Apply anti-galling compound to casing bolts for easier disassembly.
NOTE: DO NOT overtighten casing jack screws.
2. Inspect stuffing box cover run-out by rotating indicator through 360 degrees. Total indicator reading greater than
.005" (.13mm) indicates a problem.
3. Install the shaft sleeve (126).
NOTE: Apply anti-galling compound to the sleeve bore for easier disassembly.
NOTE: Sleeve must be fully seated.
Warning:
Wear a heavy set of work gloves when handling impeller
(101) as sharp edges may cause physical injury.
5. Replace shims under frame foot and tighten frame foot to baseplate. To ensure that the proper shim is used, a dial indicator should be mounted to measure distance between top of frame and baseplate. This distance should not change as frame foot bolting is tightened.
6. Check total travel of impeller in casing. With new parts, acceptable range is .030" (.76mm) to .065" (1.65mm). If outside this range, improper parts or installation or too much pipe strain is present. Determine cause and correct.
7. Adjust impeller clearance according to procedure outlined in
Appendix I.
8. Replace auxiliary piping at this time.
9. Fill pump with proper lubricant.
4. Install impeller (101) with new O-ring (412). Place shaft wrench and coupling key on shaft. When impeller makes firm contact with sleeve (126), raise shaft wrench
(counterclockwise as viewed from impeller end of shaft) off bench then slam it down (clockwise as viewed from impeller end of shaft). A few sharp raps will properly tighten impeller.
5. Release clamp bolts (370C) and jacking bolts (370D). Use a feeler gauge to measure gap between impeller (101) and seal chamber/stuffing box cover (184). Tighten clamp bolts
(370C), jacking bolts (370D) and locking nuts (423) when
.030" (.76mm) clearance is reached.
NOTE: The above steps approximate the impeller position when set at .015" (.38mm) from casing.
6. Check impeller run-out by checking vane tip to vane tip.
Total indicator reading greater than .005" (.13mm) indicates a problem. Take steps to resolve problem before continuing.
17
3500 SERIES / MODEL 3550
INSTALLATION TROUBLESHOOTING GUIDE
Fault
Excessive shaft end play.
Possible Cause
Bearing internal clearance too great.
Remedy
• Reduce speed level.
Snap ring loose in bearing housing groove.
Excessive shaft/sleeve run-out. Sleeve worn.
Shaft bent.
• Reseat.
• Replace.
• Replace.
Excessive bearing frame flange run-out.
Shaft bent.
• Replace.
Bearing frame flange distorted. • Replace.
Excessive frame adapter runout.
Corrosion.
• Replace.
Frame gasket adapter not seated correctly.
• Reseat.
• Reseat.
Excessive seal chamber/stuffing box cover run-out.
Seal chamber/stuffing box cover improperly seated in frame adapter.
Excessive impeller vane tip run-out.
Corrosion/wear.
Bent vane/vanes.
• Replace.
• Replace impeller.
18
136
332
400
370C 382 134 112 408H 113 228
3500 SERIES / MODEL 3550
168
S – PUMP CROSS SECTIONAL
408H 333 126 370 503
353
107
106
105
355
351
122
497F
497G
370D
423
496 361A 408H 408M 408L 408A 408J 319 408H 497J 497H 418 250 370H 357K 360Q
382
134
136
332
400
370C 408H 361A 113 228 408H
M – PUMP CROSS SECTIONAL
370B 360D 333 108 370 106 105 351
107
353
355
126
122
497F
497G 370D 423 496 112 408H
370F
241
497J
168
497H
408J 408M 408A 408L 319 408H 469B 418
250 370H
357K 360Q
101
412
100
184
100
184
101
412
19
134
382
136
332
400
370C 408H 253B 236A 113 228
3500 SERIES / MODEL 3550
L – PUMP CROSS SECTIONAL
408H 370B 360D 333 108 370 105
106
351
107
355
126
353
122
497F
497G
370D
423
496 112
408H 248 408J
370F
241
168 497J 497H
408M 408L 408A 319 408H 469B 418
250 370H 357K 360Q
497F
497G
371C
360
400
122
136
109
332
382 370C 408H 134 228 168
XL – PUMP CROSS SECTIONAL
408H 333
355 353 107 106 105
113
136
370B
370D 423 496 112
370F 241 408J 408M 408L 319 408A 469B 497J
250 370
351
418 497H 360Q 357K
412
100
184
101
100
184
101
412
20
351
353
355
357K
358A
360
360A
370
418
469B
496
496A
184
228
241
250
319
332A
333A
112
122
122
126
134
136
168
Item
Number
100
101
105
106
107
108
* E.I. DuPont Registered Trademark
** NOTE: L Power End features Duplex Angular Contact.
4
2
1
4
1
1
1
2
1
3
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Req’d Per
Pump
1
1
1
1
1
1
3500 SERIES / MODEL 3550
PARTS & MATERIAL COMPOSITION
Part Name
Casing
Impeller
Lantern Ring
Packing
Packing Gland
Frame Adapter
Outboard (Thrust) Bearing
Shaft – Less Sleeve (Optional)
Shaft – With Sleeve
Shaft Sleeve
Bearing Housing
Lock Nut / Lock Washer
Inboard (Radial) Bearing
Stuffing Box
Frame
Frame Foot
Gland
Sight Oil Gauge
Labyrinth Oil Seal (Outboard)
Labyrinth Oil Seal (Inboard)
Casing Gasket
Gland Stud
Gland Nut
Hex Nut
Casing Drain Plug (Optional)
Gasket, Frame-to-Adapter
Gasket, Bearing End Cover
Bearing Housing Hex Bolt
Casing Jack Screw
Dowel Pin
Bearing Housing O-Ring
Impeller O-Ring
All
Iron
Ductile Iron
Ductile Iron
316SS
Ductile Iron
Steel
316SS
316SS
All
316SS
316SS
316SS
All
Alloy 20
Alloy 20
All
CD4MCu
CD4MCu
Alloy 20 CD4MCu
Glass Filled Teflon*
Teflon* Impregnated Fibers
Alloy 20
Ductile Iron
Double Row Angular Contact**
316SS
All
Titanium
Titanium
Titanium
Titanium
Hastelloy
B&C
Hastelloy B&C
Hastelloy B&C
Hastelloy B&C
316SS
SAE4140
Alloy 20 316SS
Cast Iron
Steel
Single Row Deep Groove
316SS
Titanium
316SS
Hastelloy B&C
Alloy 20 CD4MCu
Cast Iron (Ductile for Small Frame)
Cast Iron
Alloy 20
Titanium Hastelloy B&C
316SS
Bronze (Optional Carbon Filled Teflon)
Bronze (Optional Carbon Filled Teflon)
316SS
Aramid Fiber with EPDM Rubber
316SS
304SS
304SS
Alloy 20 316SS
Vellumoid
Vellumoid (XL Only)
Steel
Steel
Steel
Buna Rubber
Glass Filled TFE
Titanium Hastelloy B&C
SPARE PARTS
Keep the following components on hand as spare parts (at minimum):
Impeller (101)
Recommended Spares – All Pumps
Bearing Lockwasher (382)
Shaft (122A)
Shaft Sleeve (126) if used
Outboard, Thrust Bearing (112A)
Bearing Locknut (136)
Impeller O-ring (412A)
Bearing Housing O-ring (496)
Inboard, Radial Bearing (168A)
Casing Gasket (351)
Frame-to-Adapter Gasket (360D)
Bearing Housing Retaining Ring (361A)
Outboard Lab Seal Rotary O-ring (497)
Outboard Lab Seal Stationary O-ring (497G)
Inboard Lab Seal Rotary O-ring (497H)
Inboard Lab Seal Stationary O-ring (497J)
21
3500 SERIES / MODEL 3550
APPENDIX I: IMPELLER CLEARANCE ADJUSTMENT: TABLE 1:
FEELER GAUGE METHOD:
1. Lock out power supply to motor.
2. Remove coupling guard and spacer.
3. Loosen jack bolts (370D) and jam nuts (423).
4. Tighten bearing housing bolts (370C) evenly while slowly rotating the shaft. Continue rotating until the impeller begins to rub the casing.
5. Use a feeler gauge to set the gap between the three housing bolts (370C) and bearing housing. Consult the table below for gap settings.
6. Tighten jacking bolts (370D) evenly until bearing housing backs out and makes contact with bearing housing bolts
(370C).
7. Tighten jam nuts (423) evenly. Rotate shaft to check for free turning.
Impeller Clearance at Ambient for Various Service Temps.
Pumpage
Temperature
–20º to 200ºF
(–7º to 93ºC)
Up to 250ºF
(121ºC)
Up to 300ºF
(149ºC)
Up to 350ºF
(177ºC)
Up to 400ºF
(204ºC)
Up to 450ºF
(232ºC)
Up to 500ºF
(260ºC)
S
0.005"
(0.0127)
0.006"
(0.0152)
0.007"
(0.0178)
0.009"
(0.0229)
0.010"
(0.0254)
0.011"
(0.0279)
0.012"
(0.0305) in inches (cm)
Pump Frame Size
M L
0.008"
(0.0232)
0.009"
(0.0229)
0.010"
(0.0254)
0.012"
(0.0305)
0.013"
(0.0330)
0.014"
(0.0356)
0.015"
(0.0381)
0.18"
(0.4572)
0.19"
(0.4826)
0.20"
(0.5080)
0.22"
(0.5588)
0.23"
(0.5842)
0.24"
(0.6096)
0.25"
(0.6350)
XL
0.015"
(0.0381)
0.016"
(0.4064)
0.017"
(0.0432)
0.019"
(0.0483)
0.020"
(0.0508)
0.021"
(0.0533)
0.22"
(0.5588)
8. Reinstall coupling spacer and guard.
DIAL INDICATOR METHOD:
APPENDIX II: COUPLING GUARDS INSTALLATION
INSTRUCTIONS:
1. Lock out power supply to motor.
2. Remove coupling guard and spacer.
3. Place a dial indicator with a magnetic mounting base on the surface of the pump baseplate. Indicator should be placed against face of pump shaft.
4. Loosen jacking bolts (370D) and jam nuts (423).
Warning:
Before assembly or disassembly of the coupling guard is performed the motor must be de-energized, the motor controller/starter put in a locked-out position and a caution tag placed at the starter indicating the disconnect. Replace coupling guard before resuming normal operation of the pump. Pump manufacturer assumes no liability if this requirement is not followed.
5. Tighten bearing housing bolts (370C) evenly while slowly rotating the shaft. Continue rotating until the impeller begins to rub the casing. Set the dial indicator to zero.
6. Tighten jacking bolts (370D) evenly until they contact the bearing frame. Continue tightening the jacking bolts
(about one flat at a time), drawing the bearing housing away from the frame until the dial indicator shows appropriate clearance.
Simple design allows complete assembly of the coupling guard in about 15 minutes, including assembly of the end plate (pump end). Assembly can be accomplished in about five minutes if the end plate is already in place.
ASSEMBLY:
NOTE: If end plate (pump end) is already installed, make any necessary coupling adjustments and proceed to Step 2.
7. Tighten bearing housing bolts (370C) evenly before tightening jacking bolts (370D). Check that the dial indicator reading does not move from the appropriate setting. Rotate shaft to check for free turning.
8. Reinstall coupling spacer and guard.
1. S, M, L Models: Align end plate (pump end) to bearing frame (no impeller adjustment required).
XL Model: Align end plate (pump end) to pump bearing housing so that 1) large slots on end plate clear bearing housing tap bolts and 2) small slots are aligned to impeller adjusting bolts. Attach end plate to bearing housing using jam nuts on impeller adjusting bolts.
Check and reset impeller clearance after end plate is attached to bearing housing.
NOTE: Complete coupling adjustments before proceeding with coupling guard assembly.
2. Spread bottom of coupling guard half (pump end) slightly and place over pump end plate (the annular groove in the guard half is located around the end plate).
22
3500 SERIES / MODEL 3550
3. Once coupling guard half (pump end) is located around end plate, tighten it securely with a bolt, nut and two washers through the round hole at front end of guard half.
DISASSEMBLY: Remove the coupling guard for certain maintenance and adjustments to the pump. Specific instances include adjustment of the coupling, impeller clearance adjustment, etc. The coupling guard must be replaced after completing maintenance procedures.
4. Spread bottom of coupling guard half (driver end) slightly, then place over coupling guard half (pump end). Check that annular groove in coupling guard half (driver end) faces motor.
5. Place end plate (driver end) over motor shaft. Locate end plate in annular groove at rear of coupling guard half (driver end), then hand-tighten with a bolt, nut and two washers through the round hole at rear of guard half.
DO NOT resume pump operation with the coupling guard removed.
NOTE: For reverse order assembly, refer to diagrams.
1. Remove nut, bolt and washers from center slotted hole in coupling guard. Slide motor end coupling guard half toward pump.
6. To completely cover shafts and coupling, adjust length of coupling guard by sliding coupling guard half (driver end) toward motor. Secure with bolt, nut and two washers through slotted holes at center of guard and tighten. Inspect all nuts on guard assembly for proper tightness.
2. Remove nut, bolt and washers from coupling guard half
(driver end) and remove end plate.
3. Spread bottom of coupling guard half slightly and lift off.
Warning:
Before assembly or disassembly of the coupling guard is performed, the motor must be de-energized, the motor controller/starter put in a locked-out position and a caution tag placed at the starter indicating the disconnect. Replace coupling guard before resuming normal operation of the pump.
4. Remove remaining nut, bolt and washers from coupling guard half (pump end). Spread bottom of coupling guard half slightly and lift off.
Disassembly of the coupling guard is now complete.
NOTE: Bearing housing tap bolts are accessible without removing end plate if maintenance of internal pump parts is necessary. Therefore, it is unnecessary to remove end plate (pump end) from pump bearing housing.
APPENDIX III
Bearing Fits and Tolerances - In accordance with ABEC I Standard
Radial
Bearing
(Inboard)
Shaft OD
Bearing ID
Frame/Adapter ID
Bearing OD
Bearing Fits in inches (cm)
S Frame
1.3785 (3.5014)
1.3781 (3.5003)
1.3780 (3.5001)
1.3775 (3.4989)
M Frame
1.7722 (4.5014)
1.7718 (4.5004)
1.7717 (4.5001)
1.7712 (4.4989)
2.8346 (7.1999)
2.8353 (7.2017)
2.8346 (7.1999)
2.8353 (7.2017)
3.9370 (10.0000)
3.9379 (10.0023)
3.9370 (10.0000)
3.9364 (9.9985)
Thrust
Bearing
(Outboard)
Shaft OD
Bearing ID
Bearing Housing ID
Bearing OD
1.1815 (3.0010)
1.1812 (3.0002)
1.1811 (3.0000)
1.1807 (2.9990)
2.8346 (7.1999)
2.8353 (7.2017)
2.8346 (7.1999)
2.8341 (7.1986)
1.7722 (4.5014)
1.7718 (4.5004)
1.7717 (4.5001)
1.7712 (4.4988)
3.9370 (10.0000)
3.9379 (10.0023)
3.9370 (10.0000)
3.9364 (9.9985)
L Frame
2.1660 (5.5016)
2.1655 (5.5004)
2.1654 (5.5001)
2.1648 (5.4986)
4.7244 (12.0000)
4.7253 (12.0023)
4.7244 (12.0000)
4.7238 (11.9985)
1.9690 (5.0013)
1.9686 (5.0002)
1.9685 (4.9999)
1.9680 (4.9987)
4.3307 (11.0000)
4.3316 (11.0023)
4.3307 (11.0000)
4.3301 (10.9985)
XL Frame
2.5597 (6.5016)
2.5592 (6.5004)
2.5591 (6.5001)
2.5585 (6.4986)
5.5118 (14.0000)
5.5128 (14.0025)
5.5118 (14.0000)
5.5111 (13.9982)
2.5597 (6.5016)
2.5592 (6.5004)
2.5591 (6.5001)
2.5585 (6.4986)
5.5118 (14.0000)
5.5128 (14.0025)
5.5118 (14.0000)
5.5111 (13.9982)
23
3500 SERIES / MODEL 3550
APPENDIX IV
Bolt Torque, ft.-lbs. (Nm)
Location
Casing Bolts (370) or
Casing Nuts (425)
Frame-to-Adapter
Bearing Clamp Ring Bolts (236A)
Duplex Bearing Only
Bearing End Cover Bolts (371C)
Dynamic Seal Capscrews (265)
Double Row
Duplex
S in. (mm)
.0011 (.028)
.0019 (0.47)
.0007 (.018)
.0010 (.026)
* Values are in inch-lbs. (Nm)
Frame
6" S
5/8"
8" S
1/2"
M, L
5/8"
XL
5/8"
All
S, M
L
XL
S, M, L
XL
Shaft End Play
M in. (mm)
.0013 (.033)
.0021 (.054)
.0009 (.022)
.0012 (.030)
All Materials, All Models
Lube Dry
115 (156) 173 (235)
58 (79)
115 (156)
115 (156)
20 (27)
10* (1.1)
55* (6.2)
9 (12)
55* (6.2)
9 (12)
L in. (mm) not applicable
.0010 (.026)
.0015 (.038)
87 (118)
173 (235)
173 (235)
30 (40)
17* (1.9)
83* (9.4)
12 (16)
83* (9.4)
12 (16)
XL in. (mm)
.0014 (.036)
.0023 (.058)
.0010 (.026)
.0015 (.038)
APPENDIX V:
Never mix greases of different consistencies or types.
BEARING ISOLATORS:
The Aurora model 3550 pump comes with Impro ® bearing isolators. These labyrinth seals are highly effective at keeping oil in the bearing frame while keeping contaminants out. The drain hole must be at the bottom (6 o’clock position) for proper operation. This seal has a theoretically infinite life as it is a noncontacting seal; however, it can be damaged through an outright bearing failure in close clearance situations. The rotor is driven by a replaceable O-ring which fits onto the pump shaft. The stator OD is sealed with a replaceable O-ring. A third O-ring is internal to the seal and cannot be replaced. Due to this, treat the seal as an assembly and replace it as such if necessary.
2
5
9
1
VBX ® O-RING ACTION
8
3
7
6
4
1. ROTOR
2. STATOR
3. VBX ® RING
4. ROTOR DRIVE RING
5. STATOR GASKET
6. EXPULSION PORT
7. LAB GROOVE
8. LUBE RETURN
9. LOCATION RAMP
24
3500 SERIES / MODEL 3550
Maximum Working Pressure Limits
Models S, M, L; Class 150 Flanges temperature – degrees Celcius
Maximum Working Pressure Limits
–240 –200 –160 –120 –80 –40 0 40 60 80 120 160 200 240 280
Models S, M, L; Class 150 Flanges temperature – degrees Celcius
300 HASTELLOY ® B&C
–240 –200 –160 –120 –80 –40 0 40 60 80 120 160 200 240 280
316
250
300 HASTELLOY ® B&C
200
250
W-20
316
MONEL ®
150
200
100
150
100
50
0
50
–400 –300 –200 –100
W-20
MONEL ®
NICKEL
0 100 200 300 temperature – degrees Fahrenheit
400 500
22
20
600
8
4
6
2
4
0
22
18
20
16
18
14
16
12
14
10
12
8
10
6
2
0
0
–400 –300 –200 500 600 –100 0 100 200 300 temperature – degrees Fahrenheit
400
Maximum Working Pressure Limits
Models S, M, L; Class 300 Flanges temperature – degrees Celcius
Maximum Working Pressure Limits
–240 –200 –160 –120 –80 –40 0 40 60 80 120 160 200 240 280
Models S, M, L; Class 300 Flanges temperature – degrees Celcius
400
TYPE 316, W-20, MONEL ® , NICKEL, HASTELLOY ® B&C
–240 –200 –160 –120 –80 –40 0 40 60 80 120 160 200 240 280
NICKEL
350
400
TYPE 316, W-20, MONEL ® , NICKEL, HASTELLOY ® B&C
28
28
24
200
350
NICKEL
24
14
100
200
14
7
100
0
–400 –300 –200 –100 0 100 200 300 temperature – degrees Fahrenheit
400
0
–400 –300 –200 –100 0 100 200 300 temperature – degrees Fahrenheit
400
500
500
600
7
0
600
0
25
3500 SERIES / MODEL 3550
APPENDIX VII: PARTS INTERCHANGEABILITY CHART:
Impellers and casings are different for each pump size. Stuffing box covers and adapters (except for “S” frames) are shared by casing class. Check interchangeability chart for clarification.
POWER
END ADAPTER
SEAL
CHAMBER IMPELLER CASING
MODEL S
1-3/8" SHAFT DIA. – MAX BHP–40 HP
MODEL M
1-3/4" SHAFT DIA. – MAX BHP–122 HP
SIZE
1 x 1.5 - 6
AA
1.5 x 3 - 6
AB
2 x 3 - 6
AC
1 x 1.5 - 8
AA
1.5 x 3 - 8
AB
3 x 4 - 10H
A40
4 x 6 - 10
A80
4 x 6 - 10H
A80
1.5 x 3 - 13
A20
2 x 3 - 13
A30
3 x 4 - 13
A40
4 x 6 - 13
A80
3 x 4 - 7*
A70
2 x 3 - 8
A60
3 x 4 - 8
A70
3 x 4 - 8G
A70
1 x 2 - 10
A05
1.5 x 3 - 10
A50
2 x 3 - 10
A60
3 x 4 - 10
A70
POWER
END ADAPTER
SEAL
CHAMBER IMPELLER CASING
MODEL L
2-1/8" SHAFT DIA. – MAX BHP–200 HP
SIZE
1 x 2 - 10
A05
1.5 x 3 - 10
A50
2 x 3 - 10
A60
3 x 4 - 10
A70
3 x 4 - 10H
A40
MODEL XL
2-1/2" SHAFT DIA. – MAX BHP–250 HP
4 x 6 - 10G
A80
4 x 6 - 10H
A80
1.5 x 3 - 13
A20
2 x 3 - 13
A30
3 x 4 - 13
A40
4 x 6 - 13
A80
6 x 8 - 13
A90
8 x 10 - 13
A100
6 x 8 - 15
A110
8 x 10 - 15
A120
8 x 10 - 15G
A120
*In the developmental stage.
26
THIS PAGE INTENTIONALLY LEFT BLANK
WARRANTY
Seller warrants equipment (and its component parts) of its own manufacture against defects in materials and workmanship under normal use and service for one (1) year from the date of installation or start-up, or for eighteen (18) months after the date of shipment, whichever occurs first. Seller does not warrant accessories or components that are not manufactured by Seller; however, to the extent possible, Seller agrees to assign to Buyer its rights under the original manufacturer's warranty, without recourse to Seller. Buyer must give Seller notice in writing of any alleged defect covered by this warranty (together with all identifying details, including the serial number, the type of equipment, and the date of purchase) within thirty (30) days of the discovery of such defect during the warranty period. No claim made more than 30 days after the expiration of the warranty period shall be valid. Guarantees of performance and warranties are based on the use of original equipment manufactured (OEM) replacement parts. Seller assumes no responsibility or liability if alterations, non-authorized design modifications and/or non-OEM replacement parts are incorporated If requested by Seller, any equipment (or its component parts) must be promptly returned to Seller prior to any attempted repair, or sent to an authorized service station designated by Seller, and Buyer shall prepay all shipping expenses. Seller shall not be liable for any loss or damage to goods in transit, nor will any warranty claim be valid unless the returned goods are received intact and undamaged as a result of shipment. Repaired or replaced material returned to customer will be shipped F.O.B., Seller's factory. Seller will not give Buyer credit for parts or equipment returned to Seller, and will not accept delivery of any such parts or equipment, unless Buyer has obtained Seller's approval in writing. The warranty extends to repaired or replaced parts of
Seller's manufacture for ninety (90) days or for the remainder of the original warranty period applicable to the equipment or parts being repaired or replaced, whichever is greater. This warranty applies to the repaired or replaced part and is not extended to the product or any other component of the product being repaired. Repair parts of its own manufacture sold after the original warranty period are warranted for a period of one (1) year from shipment against defects in materials and workmanship under normal use and service. This warranty applies to the replacement part only and is not extended to the product or any other component of the product being repaired. Seller may substitute new equipment or improve part(s) of any equipment judged defective without further liability. All repairs or services performed by Seller, which are not covered by this warranty, will be charged in accordance with Seller's standard prices then in effect.
THIS WARRANTY IS THE SOLE WARRANTY OF SELLER AND SELLER HEREBY EXPRESSLY DISCLAIMS AND BUYER
WAIVES ALL OTHER WARRANTIES EXPRESSED, IMPLIED IN LAW OR IMPLIED IN FACT, INCLUDING ANY WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Seller's sole obligation under this warranty shall be, at its option, to repair or replace any equipment (or its component parts) which has a defect covered by this warranty, or to refund the purchase price of such equipment or part. Under the terms of this warranty, Seller shall not be liable for (a) consequential, collateral, special or liquidated losses or damages; (b) equipment conditions caused by normal wear and tear, abnormal conditions of use, accident, neglect, or misuse of said equipment; (c) the expense of, and loss or damage caused by, repairs or alterations made by anyone other than the Seller; (d) damage caused by abrasive materials, chemicals, scale deposits, corrosion, lightning, improper voltage, mishandling, or other similar conditions; (e) any loss, damage, or expense relating to or resulting from installation, removal or reinstallation of equipment; (f) any labor costs or charges incurred in repairing or replacing defective equipment or parts, including the cost of reinstalling parts that are repaired or replaced by Seller; (g) any expense of shipment of equipment or repaired or replacement parts; or (h) any other loss, damage or expense of any nature.
The above warranty shall not apply to any equipment which may be separately covered by any alternate or special warranties.
PERFORMANCE: In the absence of Certified Pump Performance Tests, equipment performance is not warranted or guaranteed.
Performance curves and other information submitted to Buyer are approximate and no warranty or guarantee shall be deemed to arise as a result of such submittal. All testing shall be done in accordance with Seller's standard policy under Hydraulic Institute procedures.
LIABILITY LIMITATIONS: Under no circumstances shall the Seller have any liability under the Order or otherwise for liquidated damages or for collateral, consequential or special damages or for loss of profits, or for actual losses or for loss of production or progress of construction, regardless of the cause of such damages or losses. In any event, Seller's aggregate total liability under the Order or otherwise shall not exceed the contract price.
ACTS OF GOD: Seller shall in no event be liable for delays in delivery of the equipment or other failures to perform caused by fires, acts of
God, strikes, labor difficulties, acts of governmental or military authorities, delays in transportation or procuring materials, or causes of any kind beyond Seller's control.
COMPLIANCE WITH LAW: Seller agrees to comply with all United States laws and regulations applicable to the manufacturing of the subject equipment. Such compliance shall include: The Fair Labor Standards Acts of 1938, as amended; Equal Employment Opportunity clauses of Executive Order 11246, as amended; Occupational Safety and Health Act of 1970 and the standards promulgated thereunder, if applicable. Since compliance with the various Federal, State, and Local laws and regulations concerning occupational health and safety, pollution or local codes are affected by the use, installation and operation of the equipment and other matters over which Seller has no control, Seller assumes no responsibility for compliance with those laws and regulations, whether by way of indemnity, warranty, or otherwise. It is incumbent upon the Buyer to specify equipment which complies with local codes and ordinances.
800 Airport Road
North Aurora, Illinois 60542
630-859-7000 www.aurorapump.com

Public link updated
The public link to your chat has been updated.
Advertisement