CMP 25506-330-000 Manual
CMP 25506-330-000 is a 20" unblockable ring drain designed for installation on the floor of hot tubs or pools. It features a single or multiple drain use design, a PVC sump body, and an open area of 46.27in2. The drain cover is designed to be replaced every seven years, and the unit comes with a protective plaster installation cover and cover screws. The maximum flow rate is 245.6GPM for two ports and 216GPM for one port. The unit is UL Listed and VGB Suction Compliant, meeting the requirements of ANSI/APSP - 16 2011 and CPSC. It is also covered by one or more U.S.
Advertisement
Advertisement
®
20 " UNBLOCKABLE RING DRAIN
25506-33X-00
All Custom Molded Products main drains are listed and tested in strict accordance to the requirements of
ANSI/APSP - 16 2011, the current standard of reference for the Virginia Graeme Baker Act, and compliant to the latest Consumer Product Safety Commission (CPSC) requirements.
UL Listed VGB Suction: Compliant to ANSI/APSP - 16 2011 & CPSC Requirements
Covered by one or more U.S. patents or pending patent applications. See www.c-m-p.com/patents for details.
TABLE OF CONTENTS
Please read through the entire manual before installing your new unit. Your pool drain fitting must be installed and operated as specified.
A. Safety Instructions & Precautions .........................................................................................
3
B. Sizing & Specification Reference ..........................................................................................
4
C. Installation & Maintenance Procedures ..............................................................................
5
1. Required for Installation ......................................................................................
5
2. Installation Location ............................................................................................
5
3. Installation Procedure .........................................................................................
5
4. Maintenance Procedure .....................................................................................
6
G. Parts List ........................................................................................................................................
8
IMAGES & TABLES IN THESE INSTRUCTIONS page 4 FLOW RATES page 4 page 4
SPECIFICATIONS
HEAD LOSS CHART page 6 page 6 page 7
INSTALLATION LOCATION
ALTERNATE PLUMBING
DIMENSIONS
2
A. SAFETY INSTRUCTIONS & PRECAUTIONS
IMPORTANT SAFETY INSTRUCTIONS.
READ AND FOLLOW ALL INSTRUCTIONS
ALWAYS PLUMB AND INSTALL ALL SUCTION FITTINGS ACCORDING TO ALL
BUILDING CODES THAT APPLY IN YOUR AREA.
WARNING
When using two or more suction fittings on a common suction line, suctions must be separated by a minimum of 3 ft or they must be located on two different planes (i.e., one on floor and one on the wall).
WARNING WARNING: DO NOT locate suction outlets on seating areas or on backrests for such seating areas.
NOTICE
Attention Installer: This manual contains important information about the installation, operation and safe use of this product. Before installing this product, read and follow all warning notices and instructions which are included. This information should be given to the owner and/or operator of this equipment.
WARNING To reduce the risk of drowning from hair and body entrapment, install suction fittings with a marked flow rate in gallons per minute that exceeds the flow rate of your system by at least 25%. Always use multiple suction outlets. If the fitting/cover breaks, is damaged, or is missing, shut the system down immediately. Do not use the system until damaged parts have been replaced.
WARNING Keep hair and clothing a minimum of 12 inches from all suction fittings and drains at all times.
Persons with long hair should secure hair to a minimal length or wear swimming cap. Children should never be left unattended at any time in a swimming pool, spa, or bathtub. Be sure the temperature of the water never exceeds the manufacturer’s recommendations.
NOTICE
NOTICE
To reduce the risk of injury, installation and service should be done by a qualified Pool Service
Professional, certified electrician or authorized CMP representative.
NOTE: In the event that one suction outlet is completely blocked, the remaining suction outlet(s) serving that system MUST have a flow rating capable of the full flow of the pump(s) for the specific suction system.
NOTICE Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapment or death.
CAUTION Hair or body parts blocking the spa or pool suctions may become trapped and held against the suction fitting. Entrapment against the suction fittings can result in drowning or other severe injury.
Never sit on or lean up against suction fittings. Never exceed the maximum allowable flow rate stated on the suction fitting. The suction fitting and fasteners should be inspected for damage or tampering before use. Missing, broken, or cracked suction fittings shall be replaced. Loose suction fittings shall be reattached or replaced before use of this facility.
SAVE THESE INSTRUCTIONS
3
B. SIZING & SPECIFICATION REFERENCE
TABLE 1: FLOW RATES
MAX FLOW RATE:
2.5" or 2” PLUMBING
FLOW RATE @1.5FPS
TWO PORTS: 245.6GPM
ONE PORT: 216GPM (second plugged or used as hydrostatic valve)
216GPM
TABLE 2: SPECIFICATIONS
PIPE SIZE
OPEN AREA
DRAIN COVER LIFE
UNBLOCKABLE
2.5
" SPIGOT / 2 " SOCKET
DO NOT adapt suction fitting to any pipe size smaller than ASTM 2”
SCH 40 PVC.
46.27in
2
7 Years. Replace drain cover and screws every seven years.
Single or multiple drain use
• Single or multiple drain use
• PVC Sump Body. Use PVC glue to attach plumbing fittings
1
3
2
5
4
6
HEAD LOSS (PA X 10�)
50 100
FLOW (GPM)
150
CHART 1: HEAD LOSS CHART
200 250
4
C. INSTALLATION & MAINTENANCE
1. REQUIRED FOR INSTALLATION
Your 20” Unblockable Ring Drain includes the following:
• Drain Sump Body
• Drain Suction Cover
• Protective Plaster Installation Cover
• Cover Screws
• 2” NPT Plugs (2)
• Optional/Not Included: Hydrostatic Relief Valve
2. INSTALLATION LOCATION
a. This suction fitting is designed for installation on the floor of hot tubs or pools. b. Do not mount directly under seats.
SAFETY CHECKLIST: c. Suction fitting and fasteners should be observed for damage or tampering before each use. d. Missing, broken, or cracked suction fittings shall be replaced before use. Loose suction fittings shall be reattached or replaced before use.
3. INSTALLATION PROCEDURE
PLUMBING: a. Install sump in the pool/spa floor. Install in the center of the pool/spa OR the deepest point.
b. It is only neccesary to run one main suction line per drain unit c. There are maximum two ports available:
• OPTION ONE: Plumb with two ports. Connect both ports to one main suction line. Plumbing to ports must be balanced.
• OPTION TWO: Plumb with one port and plug the second unused port.
• OPTION THREE: Plumb with one port and use the second port as a hydrostatic valve port.
d. Maximum flow rates will vary depending on plumbing option chosen. See Table 1 for details.
FINISHING: e. IMPORTANT! Leave the protective cover in place until plaster installation is complete.
f. Finish pool with gunite/shotcrete and plaster so that it is completely level with the sump body and cover. Ensure the finish is completely level. Pool finish should not exceed the top of the sump.
g. Remove the protective cover.
h. Attach cover/grate with the supplied screws.
5
C. INSTALLATION & MAINTENANCE
Plaster/Pool Finish
Gunite/
Shotcrete
Gunite & Plaster Filled Through Drain Center
Earth/
Substrate
IMAGE 1 - INSTALLATION LOCATION
Threaded Plug Hydrostatic
Valve
Optional Collection Tube
IMAGE 2 - ALTERNATE PLUMBING
2. MAINTENANCE PROCEDURE
a. The cover/grate and screws should be replaced at least every seven (7) years. b. Inspect pool or spa regularly to ensure that the drain cover/grate is in place and secure.
c. If the cover is found to be broken, cracked, missing, loose or missing screws it must be replaced. Do not use the pool/ facility until a repair or replacement is made.
d. If a drain cover/grate does not pass inspection:
• Close the pool or spa immediately
• Post a closure notice
• Keep the facility closed until a new drain cover and screws are properly installed.
6
D. PART DIAGRAMS AND MEASUREMENTS
1 -7/8"
17-1/2"
21-3/8"
17-3/4"
IMAGE 3 - DIMENSIONS
3-3/16"
5-1/2"
2.0"
7
G. PARTS LIST
1
3
2
8
1
2
3
––
––
CMP P/N
25506-330-000
25506-330-800
25520-050-020
25506-334-020
––
DESCRIPTION
WHITE 20” RING DRAIN COVER
WHITE 20” RING DRAIN BODY
2” PLUGS
OPTIONAL HYDROSTATIC VALVE
COVER SCREWS (8)
Parts numbers not listed in product table are only available as part of a complete assembly. See c-m-p.com or pool products catalog for other color options
SAVE THESE INSTRUCTIONS
Record Information on this System Below & Keep for Your Records
Installer _______________________________________________________________
Purchased From _______________________________________________________
Installation Date _____________________________
Model Number ______________________________
Pool Size in Gallons __________________________
CMP Customer Service & Tech Support
Toll Free: 1-800-733-9060
FAX: 770-732-7115 [email protected]
Warranty Questions
Support Resource & Videos Online c-m-p.com/resourcecenter
9
1218sb CUSTOM MOLDED PRODUCTS | 36 HERRING ROAD, NEWNAN, GA 30265 | WWW.C-M-P.COM