Sistema elettronico di controllo per piani magnetici
Electronic control system for magnetic chucks
Système électronique de commande pour des plateaux magnétiques
Elektronisches Steuersystem für Magnetplatten
Sistema electrónico de control para planos magnéticos
ST100
ST200
Manuale uso e manutenzione
Instruction and maintenance manual
Manuel d’utilisation et d’entretien
Betriebs- und Wartungsanleitung
Manual de uso y mantenimiento
Nr. 50 100 7816
INDEX
4
4.1
4.2
4.3
3
3.1
3.2
3.3
3.4
2.1
2.2
2.3
2.4
1
1.6
1.7
1.8
1.9
1.10
1.1
1.2
1.3
1.4
1.5
1.11
1.12
1.13
GENERAL NOTES
..................................32
Overview.of.the.company...........................32
Importance.of.the.manual...........................33
Storing.the.manual......................................33
Conventions................................................33
Definition.of.symbols...................................33
Personnel.responsible.for.operations..........33.
Trained.personal..........................................34
Individual.protection.means........................34.
General.safety.precautions.........................34
Behavior.during.emergency.situations........34
Limitations...................................................34
Improper.or.non.permitted.use...................35
Nameplate.data...........................................35
2 TRANSPORTATION AND
HANDLING
...............................................36
Receipt........................................................36
Handling......................................................36
Transportation.............................................36
Storage........................................................36
DESCRIPTION OF THE SYSTEM
.......37
Description.of.the.controllers......................37
Model.ST100X.............................................37
Model.ST200X.............................................38
Control.push-buttons.for.ST.controllers......39
5
5.1
5.2
6
6.1
6.2
6.3
INSTALLATION
.......................................43
General........................................................43
Connecting.ST100.controllers.to.the.
power.supply...............................................44
Connecting.ST200.controllers.to.the.
power.supply...............................................44
ENABLING
..............................................45
ST100..........................................................45
ST200..........................................................45
OPTIONAL COMPONENTS
................46
Starting.the.ST100.controller......................46
Push-button.panels.of.models.ST100.
and.ST200...................................................46
QE.version...................................................46
7
Page
PLC
............................................................46
8
8.1
8.2
8.3
8.4
Page
CONNECTION TO
TECNOMAGNETE MODULE
..............48
Installation.of.miller.ST100..........................48
Installation.of.grinder.ST100.......................48
Installation.of.miller.ST200..........................49
Installation.of.grinder.ST200.......................50
9
9.1
9.2
10
ORDINARY USE
......................................51
ST100..........................................................51
ST200..........................................................51
ANALYSIS OF RESIDUAL RISKS
.......52
11
11.1
11.2
11.3
11.4
11.5
11.6
11.7
MAINTENANCE
......................................52
Premise........................................................52
Maintenance.safety.instructions.................52
Weekly.maintenance...................................53
Monthly.maintenance..................................53
Maintenance.to.be.carried.out.every.
six.months...................................................53
Extraordinary.maintenance.........................53
Information.on.extraordinary.reparation.
and.maintenance.........................................53
12 TROUBLESHOOTING AND
CORRECTIVE ACTIONS
.......................54
13
13.1
13.2
DECOMMISSIONING AND
DISPOSAL
................................................54
Decommissioning........................................54
Dismantling..................................................54
14
14.1
14.2
WARRANTY AND TECHNICAL
SUPPORT
.................................................55.
Warranty.terms.and.conditions...................55
Invalidity.of.warranty...................................55
15 TECHNICAL SUPPORT SERVICE
.....56
DELARATION OF
CONFORMITY
........................................57
Edition:.07-12
Replaces:.03-09.
Instruction and maintenance manual 31
1
..
GENERAL NOTES
&
Thank.you.for.purchasing.one.of.the.many.products.
manufactured.by..
TECNOMAGNETE S.p.A.
This.manual.is.designed.to.help.you.become.familiar.
with.your.new.product.and.must.therefore.be.carefully.read.and.followed.
For.further.information.on.the.system,.you.can.contact.
TECNOMAGNETE’s . technical. support. at. any.
time.
The. descriptions. and. illustrations. provided. in. this.
manual.are.for.reference.only.
While. confirming. the. general. characteristics.
of. the. controllers. described. in. the. manual,.
TECNOMAGNETE S.p.A.
. reserves. the. right,. at. its.
discretion,.to.change.at.any.time.some.of.the.characteristics.in.order.to.improve.the.product.or.due.to.
manufacturing.and.commercial.reasons..The.necessary.updates,.if.required,.shall.be.supplied.as.attachments.
This.manual.is.property.of.
TECNOMAGNETE S.p.A.
.
and.cannot.be.copied.in.whole.or.in.part.or.made.
available.to.third.parties.without.the.written.authorization.of.the.manufacturer..Should.the.products.be.
amended. and/or. updated,. upon. authorization. of.
TECNOMAGNETE S.p.A., . the. manufacturer. shall.
integrate. the. existing. manual. by. providing. the. text.
explaining.the.use.of.the.modified/integrated.component.along.with.a.description.of.potential.residual.
risks..
1.1 Overview of the company
TECNOMAGNETE started. its. activities. in. 1972. as.
manufacturer. of. permanent-electro. magnetic. systems.designed.to.ensure.power,.flexibility.and.maximum.safety..Its.state-of-the-art.technologies.and.the.
patents.developed.over.the.years.have.enabled.the.
company. to. become. a. leading. supplier. in. several.
international.markets.
The.permanent-electro.magnetic.systems.manufactured.by.TECNOMAGNETE.are.able.to.produce.all.
the. magnetic. force. required. both. to. clamp. and. lift.
work.pieces,.thus.eliminating.the.need.of.using.electric.power.during.machining.
Its.main.fields.of.activity.include:
CLAMPING SECTION FOR LIFTING
•.
MTE permanent-electro .lifters.designed.to.enable.the.handling.of.ferrous.loads.of.any.shape.and.
dimension.
•.
BAT-GRIP permanent-electro lifters. with. incorporated.battery.
•.
MaxX manual lifters.
WORK HOLDING LINE .
•.
QUADSYSTEM chucks .for.millers.and.machining.
centers.of.all.sizes.
•.
TFP0 .and.
TFP1 .for.high.precision.grinding.
•.
RADIAL-POLE chucks . for. finishing. or. roughing.
operations.on.boring.mills.
•.
QUAD-RAIL modules . to. clamp. rails. of. varying.
lengths.
•.
MDS .chucks.for.
EDM .machines.
STAMPING and MOLDING LINE
•.
QUAD-PRESS systems to.clamp.molds.
.
TECNOMAGNETE. has. installed. approximately.
50,000.units.in.over.twenty.years,.thanks.mainly.to.
its.wide-ranging.offer,.its.flexibility.to.meet.customers’. requirements. and. its. efficient. post-sales. service.
32 Instruction and maintenance manual
1.2 Importance of the manual 1.5 Definition of symbols
A.copy.of.this.manual.must.always.be.made.available.to.the.operators.responsible.for.the.installation,.
operation.and.maintenance.of.the.controller.in.order.
to.allow.them.to.carry.out.all.the.required.operations.
in.compliance.with.the.instructions.provided.in.the.
manual.
A. full. compliance. with. the. instructions. provided. in.
this.manual.is.an.essential.requirement.to.be.able.to.
correctly.use.the.equipment.and.ensure.the.safety.of.
.
operators.and.other.people..
The. manual. forms. integral. part. of. the. controller..
Therefore,.all.reproduction.and.divulgation.rights.related.to.the.manual.or.its.exhibits.are.reserved.
The.manual.must.always.be.transferred.to.the.new.
owner.of.the.machine.if.the.latter.is.sold.
All.information.related.to.safety.is.highlighted.in.bold.
All.warnings.that.draw.the.attention.of.operators.on.
operations.that.may.be.hazardous.in.terms.of.safety.
or.health.or.that.may.cause.physical.injuries,.if.the.
applicable. instructions. are. not. followed,. are. highlighted. in. red. and. marked. with. the. following. symbol:
All. warnings. related. to. operations. that. have. to. be.
carried. out. by. skilled. and. qualified. personnel. are.
highlighted. in. bold. and. marked. with. the. following.
symbol:.
1.3 Storing the manual
1.6 Personnel responsible for operations
It.is.severely.forbidden.to.remove.parts,.tear.pages.
or.alter.this.manual.
The.manual.should.always.be.carefully.preserved.so.
that.it.is.not.damaged.
Always.protect.the.manual.from.excessive.humidity.
and.heat.and.store.it.in.a.location.where.it.can.be.
easily.accessed.by.operators.in.case.of.need.
1.4 Conventions
To.simplify.consultation,.the.manual.has.been.divided.into.the.following.hierarchical.order.so.that.each.
phase.is.described.in.detail:
1
.
1.1
.
1.1.1
.
Section.1.of.the.manual.
Chapter.1.of.Section.1.of.the.manual.
Paragraph.1.of.Chapter.1.of.Section.1.of.
the.manual.
1.1.1.1
.
Subparagraph.1.of.paragraph.1.of.Chapter.1.of.Section.1.of.the.manual.
Some.chapters.and/or.sections.contain.bulleted.lists.
to.allow.operators.to.follow.the.operation.described.
step.by.step.
Parts.that.require.specific.attention.are.highlighted.
with.symbols.
Instruction and maintenance manual
Some.operations,.as.stated.in.this.manual,.can.only.
be.performed.by.qualified.and.skilled.personnel..The.
qualification.level.is.described.by.means.of.the.following.standard.definitions:.
•. Qualified. personnel. is. personnel. with. specific.
technical.knowledge.and/or.the.experience.necessary. to. avoid. potential. risks. originating. from.
power.supply.(engineers.and.technicians)...
•. Trained.staff.is.personnel.that.operates.following.
the. instructions. and/or. under. the. supervision. of.
qualified.personnel,.who.is.responsible.for.verifying.that.they.are.not.exposed.to.potential.hazards.
resulting.from.the.contact.with.power.(personnel.
responsible.for.operation.and.maintenance)..This.
personnel.must.have.the.following.qualifications:
1..All.personnel.must.be.trained.and.authorized.to.
disconnect.the.machine.from.the.power.supply,.to.
connect.it.to.the.grounding.system.and.to.mark.
circuits.and.equipment.following.standard.safety.
procedures..
2..All.personnel.must.have.been.specifically.trained.
to. follow. correct. maintenance. procedures. and.
use.the.protective.equipment.in.accordance.with.
standard.safety.procedures.
•. Before.using.the.unit,.users.shall.always.have.to.
verify.with.authorized.personnel.that:
1..All.personnel.has.received.a.copy,.has.read.and.
understood.the.content.of.the.instruction.manual.
2..All.personnel.has.agreed.to.follow.the.instructions.
provided.
33
1.7 Trained personal
•. OPERATORS:. workers. who,. after. receiving. the.
necessary.instructions,.have.been.authorized.by.
the.owner.to.operate.the.controller.and.the.equipment.connected.to.it..Workers.with.this.qualification.must.be.thoroughly.familiar.with.the.content.
of.this.manual.
•. ELECTRIC. MAINTENANCE. TECHNICIAN. (ref..
EN60204.paragraph.3.45):.this.qualification.is.assigned.to.all.personnel.specifically.trained.to.perform.operation.on.electric.components,.which.include. connections,. adjustments,. maintenance.
and/or.reparations,.and.to.personnel.who.is.qualified.to.perform.operations.inside.electric.cubicles.
and. boards.. This. qualification. implies. having. a.
perfect. knowledge. and. full. familiarity. with. the.
content.of.this.manual.
All operators are therefore expected to follow the instructions below and to thoroughly comply with the safety procedures concerning the installation and use of the equipment applicable in the country in which the unit is used.
All ordinary and extraordinary maintenance operations shall have to be carried only after the unit has been disconnected from the power supply.
Before connecting the power cable, it is essential to verify that the line voltage complies with the one shown on the nameplate of the controller.
All transportation, installation, ordinary and extraordinary maintenance operations performed on the controller must be carried out only by personnel with the qualifications stated in Chapter
1.6 and 1.7.
1.8 Individual protection means
1.10 Behavior during emergency situations
The personnel referred to in the paragraph above must always wear suitable protective clothing and use the protection means generally required to operate the tool machine on which the Tecnomagnete module and controller are installed.
In particular, personnel shall always have to wear industrial shoes along with ear protection, helmets and goggles, if required.
All personnel should refrain from wearing loose clothing that could get tangled with moving components.
In the event of emergency, it is always advisable to follow the procedures outlined in the operation and maintenance manual of the machine on which the controller is installed.
In the event of fire, always use the extinguishing means provided being careful not to use water to extinguish fires on electric parts.
1.11 Limitations
1.9 General safety precautions
The unit can be used only for the applications specified in operating instructions and only in combination with the equipment and components recommended by TECNOMAGNETE S.p.A.
The instructions and recommendations provided below comply with current safety regulations and imply the obligation of complying with applicable provisions.
TECNOMAGNETE S.p.A. shall not be responsible for damages caused to people or equipment originating from the failure to follow applicable safety provisions and to comply with the instructions given below.
34 Instruction and maintenance manual
1.12 Improper or non permitted use
The controller is not designed and has not been manufactured to be used in explosive environments.
An improper use may:
• Cause injuries to personnel.
• Damage the controller or any other equipment connected to it.
• Affect the reliability and performance of the controller.
In particular, it is essential to adhere to the following instructions:
• Always use suitable working parameters.
• Carry out the required maintenance in accordance with the instructions provided.
• Use suitable equipment.
• Comply with all the instructions provided.
• Fix the unit onto a stable surface.
• Contact TECNOMAGNETE S.p.A. in case of doubt to determine whether a specific operation is permitted.
1.13 Nameplate data
The.controller.is.fitted.with.an.identification.label.in.
compliance.with.current.laws.
ATTENTION
The nameplate should never be removed even if the unit is resold.
If the nameplate is damaged or has been removed, it is necessary to contact
TECNOMAGNETE S.p.A. to order a duplicate.
Always quote the model printed on the nameplate in all communications with
TECNOMAGNETE S.p.A.
Failure to comply with the above instructions shall entitle TECNOMAGNETE S.p.A. to disclaim any responsibility for injuries to personnel and damage to equipment, making the user fully responsible before competent authorities.
Instruction and maintenance manual 35
2
TRANSPORTATION AND
HANDLING
The.unit.is.shipped.in.a.cardboard.box,.covered.with.
a.plastic.sheet.and.enveloped.by.polyurethane.foam.
to.protect.it.from.damage.in.the.event.of.impacts.or.
accidents.
2.1 Receipt
All. units. are. carefully. inspected. before. shipping..
Upon. receipt,. customers. should. verify. that. the.
packaging. and. the. material. inside. it. has. not.
been. damaged. (unless. otherwise. instructed. by.
TECNOMAGNETE.S.p.A.).in.order.to.ensure.that.the.
unit.has.not.been.damaged.during.transport.and.that.
the.material.supplied.complies.with.order.specifications..Visible.transport.damages.should.be.immediately.reported.to.TECNOMAGNETE.S.p.A..and.the.
forwarding.agent.
2.3 Transportation
The.unit.should.always.be.transported.within.the.following. environmental. limits:. temperature. ranging.
from.–10°C.to.+55°C,.with.temperature.increase.up.
to.70°C.for.a.maximum.of.24.hours.
If.the.unit.requires.the.use.of.specific.transportation.
means.(by.sea.or.air),.special.provisions.shall.have.to.
be. adopted. in. order. to. protect. it. from. damages.
caused. by. potential. impacts.. The. box. should. also.
contain. hygroscopic. salts. to. protect. the. unit. from.
atmospheric.agents.
ATTENTION
All.damages.and.anomalies.must.be.reported.within.
ten.days.from.receiving.the.goods.
2.2 Handling
Weight.of.model.ST100:.0,4.kg.
Weight.of.model.ST200:.2,0.kg.
Always keep the original packaging so that it can be used to transport the unit if needed.
2.4 Storage
.
The. unit. should. always. be. throughly. cleaned. and.
adequately.protected.when.stored.for.long.periods.
of.time.
Disconnect.the.controller.from.the.magnetic.chuck.
and.from.the.power.supply.
It.is.generally.advisable.to.cover.the.unit.with.a.waterproof.bag.and.store.it.in.dry.and.safe.place.
The. temperature. of. the. storage. area. should. range.
between.0°C.(32°F).and.55°C.(131°F).
Relativy.humidity.should.be.between.30%.and.90%,.
non.condensing.
The. atmosphere. should. be. clean,. free. from. acids,.
corrosive.gases,.salts,.etc
When.restarting.the.machine,.always.follow.the.instructions.provided.in.Chapter.4.
36 Instruction and maintenance manual
3
..
DESCRIPTION
OF THE SYSTEM
3.1 Description of the controllers
ST . is. an. innovative.
electronic controller for networked chucks . designed. for. milling. and. grinding.operations.
The.sections.that.follow.provide.information.on.the.
size. and. the. basic. characteristics. of. the. available.
models:
• ST100F (milling)
• ST100R (grinding)
• ST200F (milling)
• ST200R (grinding) rate.a.maximum.power.of.4kVA..For.example,.if.the.
available. voltage. is. 400V,. a. transformer. with. a.
400/230.transformation.ratio.is.required.
ATTENTION! .Control.units.can.be.moved.only.
when.controls.are.not.powered.
135
135 40
75
50
3.2 Model ST100X
The.rated.operating.voltage.is.230V.
The.control.push-button.panel.is.integrated.in.to.the.
controller.
The.control.electronics.are.situated.under.the.control.
push-button. panel. and. enclosed. in. a. plastic. housing.
To. simplify. installation. and. facilitate. the. reading. of.
the. push-button. panel,. it. is. also. possible. to. install.
the.controller.on.a.workbench.or.mount.it.on.the.wall.
by.simply.rotating.the.control.panel.
The. plastic. material. of. the. housing. ensures. a. high.
level.of.insulation.and.the.utmost.safety.during.use.
The.rear.part.of.the.controller.has.a.block.with.a.male.
pin.(designed.to.be.connected.to.the.power.cable),.
an.ON–OFF.(0-1).switch.and.a.fuse-holder.with.two.
12.5A.protection.fuses.(type.5x20.mm)..Two.or.more.
cable.ties.for.the.output.of.the.discharge.cables.of.
the.chucks.to.be.magnetized.may.be.present.next.to.
these.components.
The. maximum. useful. current. that. flows. into. the.
ST100X. controller. is. approximately. 12.5A;. the. current.supplied.to.the.module.is.impulsive.with.a.cycle.
time.around.a.few.hundreds.of.milliseconds.(app..1.
second.per.discharge).
ST100X. controllers. are. suitable. to. control. small.
chucks. with. a. single. phase. voltage. of. 230V. and. a.
maximum.absorption.of.rated.current.of.3kW.
For.different.rated.voltages,.use.a.transformer.with.a.
suitable.transformation.ratio.and.a.rating.suitable.to.
handle.the.maximum.power.of.the.chuck.or.at.any.
Instruction and maintenance manual
Rear
135
.
Fuse-holder.. Main....
switch.
.
MAIN PARTS
A .
➜ Main.switch..
B .
➜ Push-button.panel..
C .
➜ Discharge.cable.output..
D .
➜ Start.contact..
E .
➜ Power.supply.input
40
Power.supply
input..
37
3.3 Model ST200X
The.rated.operating.voltage.of.this.controller.varies.
according.to.the.type.of.magnetic.chuck.to.which.it.
is.connected.
The.control.push-button.is.external,.but.can.also.be.
integrated.into.the.controller.
The.control.electronics.are.enclosed.in.a.metal.housing..The.metal.material.of.the.housing.is.grounded.in.
order.to.guarantee.maximum.safety.during.the.enabling.cycles.
It.is.important.to.verify.that.the.grounding.system.is.
always.in.good.working.order.
The.controller.does.not.have.a.socket.for.the.connection.to.the.power.supply..The.controller.has.an.
ON–OFF.(0-1).switch,.thus.to.adequately.protect.it.
against.short.circuits,.it.is.necessary.to.install.a.suitable.protection.system.upstream.from.the.controller..
It. is. generally. advisable. to. use. a. magneto. thermal.
switch.(curve.C).with.an.I
n
.value.compliant.with.the.
rating. specified. on. the. magnetic. chuck. nameplate.
that.will.be.connected.to.the.controller.
The. maximum. power. of. controller. ST200X. is. approximately.25kW.per.discharge.if.the.single.phase.
power.supply.is.400V,.15kW.for.power.supplies.of.
230V.and.30kW.for.power.supplies.of.480V..The.absorbed.current.is.impulsive.with.a.cycle.time.around.
a. few. hundreds. of. milliseconds. (approximately. 1.
second.per.discharge).
ST200X. controllers. are. suitable. to. power. single.
chucks. or. chucks. that. are. part. of. large. magnetic.
banks
When. using. chucks. with. a. different. rated. voltage,.
install. a. transformer. with. a. suitable. transformation.
ratio.and.a.rated.power.that.matches.the.maximum.
power.of.the.chuck.
It. is. also. possible. to. order. a. compact. version. for.
ST200-QE.electric.cabinets.with.supporting.terminal.
board,.to.power.the.controller.and.magnetic.chuck,.
with.interface.connector.and.push-button.panel.
275
331
38 Instruction and maintenance manual
3.4 Control push-buttons for ST controllers
ST.controllers.can.be.connected.to.the.push-button.
panels.described.below.
3.4.1 ST100 (basic version),
ST200 (basic version)
This. push-button. panel. is. the. base. model. used. to.
control.milling.chucks.
It.is.fitted.with.the.following.three-buttons:
•.Magnetization..
•.Demagnetization..
FULL-MAG,
DEMAG,
.
•.Enabling..
ENABLE.
The.
ENABLE .button.is.used.together.with.the.magnetization. and. demagnetization. button,. depending.
on.the.cycle.that.needs.to.be.performed.
There.are.also.4.indicator.lights.placed.next.to.the.
FULL-MAG . and.
DEMAG . buttons. and. the.
CYCLE .
and.
ALARM .symbols.
These.indicator.lights.provide.information.on.the.status.of.the.controller..When.the.controller.is.started,.
the.corresponding.LED.indicator.switches.on.
If.a.cycle.is.active,.the.only.LED.that.is.on.is.the.one.
related.to.the.cycle,.while.all.the.others.are.off.
At.the.end.of.the.cycle,.the.only.visual.indication.that.
is.on.is.the.one.related.to.the.new.system.status.
.
A
D E
B G
PUSH-BUTTON PANEL
A ➜ FULL-MAG.button
B ➜ ENABLE.button
C ➜ DEMAG.button
D ➜ MAG.led.
E ➜ Cycle.led
F ➜ DEMAG.led
G ➜ Alarm.status.led
F
C
System status MAG Led
Full-Mag
Demag.
Cycle
Current.alarm
Communication.
alarm *
* .For.version.ST200.only
Permanently.on
Off
Off
Off
Off
DEMAG Led
Off
Permanently.on
Off
Off
Off
Cycle Led
Off
Off
Permanently.on
Off
Off
Alarm Led
Off
Off
Off
Permanently.on
On.flashing
Instruction and maintenance manual 39
3.4.2 ST100 (version with 2 levels),
ST200 (version with 2 levels)
To.be.able.to.use.different.levels.of.magnetization,.it.
is. possible. to. replace. the. push-button. panel. described.above.with.a.2-level.model.that.enables.to.
control.milling.and.grinding.chucks..
.
This. push-button. panel. has. the. following. five. buttons:
•.Magnetization..
.
•.Partial.magnetization...
•.Partial.magnetization...
FULL-MAG,
MAG-1L
MAG-2L
.
•.Demagnetization.. .
•.Enabling...
.
DEMAG,
ENABLE.
The. magnetization. buttons.
MAG-1L, MAG-2L . and.
FULL-MAG .enable.to.select.three.different.levels.of.
magnetization.
The.
ENABLE .button.is.used.together.with.the.magnetization.and.demagnetization.buttons,.depending.
on.the.cycle.that.needs.to.be.performed.
There.are.also.4.indicator.lights.placed.next.to.the.
FULL-MAG . and.
DEMAG . buttons. and. the.
CYCLE .
and.
ALARM .symbols.
These.indicator.lights.provide.information.on.the.status.of.the.controller..When.the.controller.is.started,.
the.corresponding.LED.indicator.switches.on.
If.a.cycle.is.active,.the.only.LED.that.is.on.is.the.one.
related.to.the.cycle,.while.all.the.others.are.off.
At.the.end.of.the.cycle,.the.only.visual.indication.that.
is.on.is.the.one.related.to.the.new.system.status.
FULL-MAG .and.
DEMAG .indicator.lights.are.always.
on;.
MAG-1L .and.
MAG-2L .flash.only.during.partial.
magnetization.cycles.
A
G
D
B
PUSH-BUTTON PANEL
E
H
A .
➜ FULL-MAG.button
B .
➜ ENABLE.button
C .
➜ DEMAG.button
D .
➜ .FULL-MAG.led.(fixed).of.MAG.led.for.partial..
.
magnetization.(flashing).
E .
➜ Cycle.Led.
F .
➜ DEMAG.Led
G .
➜ 2nd.level.MAG.button
H .
➜ Alarm.status.Led.
I .
➜ 2nd.level.MAG.button
F
C
System status MAG Led
Full-Mag
Demag.
Mag.Level.1
Permanently.on
Off
On.flashing
Mag.Level.2
Cycle
Current.alarm
Communication.
alarm *
* .For.version.ST200.only
40
On.flashing
Off
Off
Off
DEMAG Led
Off
Permanently.on
Off
Off
Off
Off
Off
Cycle Led
Off
Off
Off
Off
Permanently.on
Off
Off
Alarm Led
Off
Off
Off
Off
Off
Permanently.on
On.flashing
Instruction and maintenance manual
3.4.3 ST200 (model with 7 levels)
To.be.able.to.use.several.levels.of.magnetization,.it.is.
possible.to.replace.the.basic.push-button.panel.with.
a.7-level.model.that.enables.to.control.milling.and.
grinding.chucks.
This. push-button. panel. has. the. following. five. buttons:
•..Magnetization..
.
MAG,
•..Increase.of.magnetization.
. level... .
.
+
.
•..Reduction.of.magnetization.
. level.. .
.
•..Demagnetization.. .
•..Enabling..
.
–
DEMAG,
ENABLE.
The.
ENABLE .button.is.used.together.with.the.magnetization.and.demagnetization.buttons,.depending.
on.the.cycle.that.needs.to.be.performed.
There.are.also.five.indicator.lights.placed.next.to.the.
full.
FULL-MAG, .
DEMAG, .
+ .and.
– .buttons.and.the.
CYCLE .and.
ALARM .buttons.
These.indicator.lights.are.used.to.provide.information.on.the.status.of.the.system,.which.is.automatically.reset.to.the.last.operating.cycle.
Once. the. start. sequence. has. been. successfully.
completed,.the.indicator.light.corresponding.to.the.
total/partial. magnetization. or. demagnetization.
switches. on,. depending. on. the. option. selected.. A.
failure.in.the.start.sequence.switches.on.the.central.
alarm.indicator.light.
If.a.cycle.is.active,.the.only.LED.that.is.on.is.the.one.
related.to.the.cycle,.while.all.the.others.are.off.
The.
FULL-MAG .and.
DEMAG .indicator.lights.are.always.on.and.flash.during.partial.magnetization.cycles.only.
A
H
C
F
B
G
I
PUSH-BUTTON PANEL
A .
➜ MAG.button
B .
➜ ENABLE.button
C .
➜ DEMAG.button
D .
➜ Button.+
E .
➜ Button.-
.
6 .
➜ FULL-MAG.Led.(fixed).of.MAG.Led.for.
..
. partial.magnetization.(flashing)
G .
➜ Cycle.Led
H .
➜ DEMAG.Led
I .
➜ Alarm.status.Led.
J .
➜ Level.selection.LED.(levels.from.1.to.7).and..
.
. FULL-MAG.8
D
J
E
System status MAG Led
Full.magnetization
Level.8
Demag.
Partial.magnetization
Levels.1-7
Cycle
Current.alarm
Communication.
alarm *
Permanently.on
Off
On.flashing
Off
Off
Off
* .For.version.ST200.only
Instruction and maintenance manual
DEMAG Led
Off
Permanently.on
Off
Off
Off
Off
Cycle Led
Off
Off
Off
Permanently.on
Off
Off
Alarm Led
Off
Off
Off
Off
Permanently.on
On.flashing
41
3.4.4 ST200 CH-ENABLE
This.push-button.panel.can.be.used.when.you.need.
to.select.different.discharge.levels.for.the.magnetic.
chucks,.i.e..enable.or.disable.the.desired.discharge.
The.push-button.panel.can.be.used.in.combination.
with.a.push-button.and.LED.to.manage.selections.
It.has.four.buttons.that.enable.to.select/deselect.the.
desired.discharge.channel..The.status.of.the.channel.
is.shown.by.the.corresponding.LED.
After. you. have. selected. the. discharge. sequence,.
you. can. also. specify. which. discharges. have. to. be.
carried.out.with.a.full.or.partial.magnetization.and/or.
select.them.with.the.appropriate.buttons.( CH1, CH2,
CH3 .and.
CH4).
The. status. LEDs. are. off. when. the. corresponding.
magnetic.chuck.is.in.
DEMAG .mode,.are.on.(though.
not.flashing).in.
FULL-MAG .mode.and.flashing.when.
the.partial.magnetization.mode.is.selected.
The. cycle. LEDs. shall. be. on. (though. not. flashing).
when.a.cycle.is.in.progress.and.off.when.no.cycle.is.
in.progress.
Alarm. LEDs. are. on. (though. not. flashing). during. all.
alarm.conditions,.except.for.communication.alarms.
A
K
G
C
E
M
I
J
F
N
PUSH-BUTTON PANEL
A ..
➜ CH1.selection.button
B ➜ CH2.selection.button
C ..
➜ CH3.selection.button
D ..
➜ CH4.selection.button
E ..
➜ FULL-MAG.Led.(fixed).of.MAG.Led.for.partial..
.
magnetization.(flashing),.discharge.1
F ..
➜ FULL-MAG.Led.(fixed).of.MAG.Led.for.partial..
.
magnetization.(flashing),.discharge.2
G ..
➜ FULL-MAG.Led.(fixed).of.MAG.Led.for.partial..
.
magnetization.(flashing),.discharge.3
H ..
➜ FULL-MAG.Led.(fixed).of.MAG.Led.for.partial..
.
magnetization.(flashing),.discharge.4
I ..
➜ Cycle Led
J ..
➜ Alarm.status
Led.
K ..
➜ CH1.selection.Led
L ..
➜ CH2.selection.Led
M ..
➜ CH3.selection.Led
N ..
➜ CH4.selection.Led
B
L
H
D
42 Instruction and maintenance manual
4
.
INSTALLATION
Check.the.supply.voltage.and.frequency.
The.electrical.supply.to.the.controller.must.be.single-phase.230V/400V/480V.(phase.+.neutral).or.twophase.(phase.+.phase)..
4.1 General
Electric.safety.can.be.guaranteed.only.if.the.electric.
system. is. correctly. connected. to. a. grounding. system.in.good.working.order,.as.foreseen.by.current.
laws. concerning. electric. safety.. Therefore,. it. is. essential.to.always.verify.this.safety.requirements.before.starting.the.unit.and.have.the.distribution.system. carefully. inspected. by. qualified. personnel. in.
case.of.doubt..TECNOMAGNETE.S.p.A..shall.not.be.
responsible.for.damages.originating.from.the.failure.
to.connect.the.unit.to.an.appropriate.grounding.system.
Users.shall.have.to.make.sure.that.the.unit.is.protected. with. a. differential. magnetothermal. switch.
suitable.to.withstand.the.rated.current.used.by.the.
system..It.is.therefore.necessary.to.install.a.suitable.
protection. with. magnetothermal. switch. (curve. C).
with.a.I
n
.value.compliant.with.nameplate.data.
TECNOMAGNETE. systems. are. permanent-electro.
systems,.which.means.that.they.need.to.be.powered.
only.during.the.short.cycle.phases..This.configuration. is. designed. to. ensure. maximum. safety. in. the.
event.of.power.failure.
TECNOMAGNETE.controllers.use.the.power.supply.
by. means. of. a. sophisticated. partializing. process,.
which.means.that.they.can.be.operated.only.when.
the.machine.is.idle.and.that.they.require.a.rated.current.that.is.normally.lower.than.the.one.required.to.
operate.the.machine.on.which.the.magnetic.system.
being.controlled.is.installed.
ATTENTION
ST100.controllers.are.designed.to.operate.with.supply.voltages.of.230V.50/60.Hz.and.cannot.therefore.
be. used. for. Tecnomagnete. modules. with. lower. or.
higher. ratings.. To. use. different. voltages,. install. a.
transformer.with.a.suitable.rating.(not.above.4.kVA).
or.contact.TECNOMAGNETE.S.p.A..for.assistance.
ATTENTION
ST200. controllers. are. designed. to. operate. with.
supply. voltages. of. 200V. -. 480V. at. 50/60. Hz. and.
can. therefore. be. used,. after. validation,. to. enable.
TECNOMAGNETE. modules. with. different. voltage.
specifications.. To. use. different. voltages,. install. a.
transformer. with. a. rating. compliant. to. that. of. the.
magnetic.chuck.or.contact.TECNOMAGNETE.S.p.A..
for.assistance.
ATTENTION
All.cables.supplied.must.have.a.bending.radius.with.
a.diameter.<10mm.and.a.tension.of.>15N/mm 2 ..Installation. must. always. be. performed. by. qualified.
technicians.in.accordance.with.current.law.requirements.
ATTENTION
Do not perform repeated MAGNETIZATION/DE-
MAGNETIZATION CYCLES
TECNOMAGNETE. systems. are. constituted. by. permanent.magnets.and.use.electric.power.only.to.enable/disable. the. area. being. machined.. Therefore,.
they. can. be. regarded. “COLD”. magnetic. clamping.
systems.
The. repetition. of. MAGNETIZATION/DEMAGNETI-
ZAZION.cycles.at.very.close.intervals.may.increase.
the. temperature. of. the. magnetic. chuck,. especially.
when.using.controllers.with.DEMAG.NUFLUX.cycle.
It.is.therefore.advisable.to.run.cycles.only.when.necessary.
The.connection.of.the.magnetic.chuck.to.the.power.
supply. must. be. carried. out. by. qualified. personnel.
only.
Instruction and maintenance manual 43
4.2 Connecting ST100 controllers to the power supply
4.2.1 Connecting the controller to the power supply
The.controller.must.be.supplied.with.a.single-phase.
voltage..The.multi-pole.cable.supplied.with.the.controller.has.three.leads.suitable.for.the.purpose.
The. controller. cannot. be. powered. from. the. threephase. +. neutral. distribution. network. that. supplies.
the.tool.machine.used..If.the.voltage.required.for.the.
controller.is.not.available,.install.a.power.transformer.
with.a.rating.suited.for.the.magnetic.chuck.
Single-phase power supply
F
N
PE
BLACK
BROWN
YELLOW/GREEN
4.2.4 Electric specifications
The.fuses.of.model.ST100.model.are.12.5A.lagged.
fuses.with.a.length.of.20.mm.and.a.diameter.of.5.mm.
(20.x.5.mm).
4.3 Connecting ST200 controllers to the power supply
4.3.1 Connecting the controller to the power supply
The.controller.must.be.supplied.with.a.single-phase.
voltage.. The. supplied. multi-pole. cable. has. three.
leads.suitable.for.the.purpose,.two.for.the.phase.and.
neutral. terminals. (or. phase). and. one. for. the. earth.
(yellow/green).
The. controller. cannot. be. powered. from. the. threephase. +. neutral. distribution. network. that. supplies.
the.tool.machine.used..If.the.voltage.required.for.the.
controller.is.not.available,.install.a.power.transformer.
with.a.rating.suited.for.the.magnetic.chuck.
Single-phase power supply
F
N
PE
BLACK
BROWN
YELLOW/GREEN
4.2.2 Power cable
TECNOMAGNETE. supplies. a. suitable. multi-pole.
power.cable.with.a.standard.length.of.two.meters,.
which.prevents.overheating.problems.and.a.voltage.
drop.within.the.rating.of.the.TECNOMAGNETE.module,.if.used.in.ordinary.operating.conditions.
Before.using.longer.cables,.always.make.sure.that.
the. cable. section. used. guarantees. a. voltage. drop.
below.1%.
Ordinary.operating.conditions.are.intended.as.intermittent.working.cycles,.with.intervals.of.at.least.one.
minute.between.two.enabling.cycles.
4.2.3 Selecting the correct dimensions for dis charge cables
The.discharge.cable.fitted.on.ST100.comprises.suitable. leads,. has. a. standard. length. of. three. meters.
and.is.dimensioned.to.prevent.overheating.and.the.
loss. of. power. on. the. chuck. in. ordinary. operating.
conditions.
Ordinary.operating.conditions.are.intended.as.enabling/disabling.cycles.occurring.at.an.interval.above.
1.minute.
Before.using.longer.cables,.always.make.sure.that.
the. cable. section. used. guarantees. a. voltage. drop.
below.1%.
44
Three-phase power supply
BLACK
BROWN
YELLOW/GREEN
R
S
T
PE
Instruction and maintenance manual
4.3.2 Power cable
TECNOMAGNETE. supplies. a. suitable. multi-pole.
power.cable.with.a.standard.length.of.four.meters,.
which.prevents.overheating.problems.and.a.voltage.
drop.within.the.rating.of.the.TECNOMAGNETE.module,.if.used.in.ordinary.operating.conditions.
Before.using.longer.cables,.always.make.sure.that.
the. cable. section. used. guarantees. a. voltage. drop.
below.1%.
Ordinary.operating.conditions.are.intended.as.intermittent.working.cycles,.with.intervals.of.at.least.one.
minute.between.two.enabling.cycles.
4.3.3 Selecting the correct dimensions for discharge cables
The.discharge.cable.fitted.on.ST200.comprises.four.
leads.suitable.for.the.purpose,.has.a.standard.length.
of. six. meters. and. is. dimensioned. to. prevent. overheating.and.the.loss.of.power.on.the.chuck.in.ordinary.operating.conditions.
Ordinary.operating.conditions.are.intended.as.enabling/disabling.cycles.occurring.at.an.interval.above.
1.minute.
Before.using.longer.cables,.always.make.sure.that.
the. cable. section. used. guarantees. a. voltage. drop.
below.1%.
4.3.4 Electric specifications
All.ST200.controllers.are.available.as.single.and.twophase. models;. the. maximum. installed. power. for.
each.cycle.is.25.kVA.(cos ϕ =0.9).for.two-phase.400V.
plants,.15kVA.for.230V.plants.and.32.kVA.for.480V.
plants.
To.optimally.protect.the.installation,.it.is.necessary.to.
install. a. suitable. magnetothermal. switch. (curve. C).
with.an.I
n
.value.compliant.with.the.rating.specified.
on.the.nameplate.
5
..
ENABLING
5.1 ST100
ST100.controllers.are.not.fitted.with.a.specific.enabling.device,.which.may.however.be.ordered.as.optional.(see.Chapter.6.1).
5.2 ST200
The.ST200.controller.has.an.enabling.device.fitted.
on.connector.DB9.situated.on.the.rear.of.the.controller.(PINS.8.and.9).
The.technical.specifications.for.the.contact.are:
•.Voltage.30V,.current.1A
•.Voltage.110V,.current.0.3A
It.is.always.advisable.to.use.an.auxiliary.relay.
Before.using.other.models.of.start.systems,.contact.
TECNOMAGNETE.S.p.A..for.assistance..
When.at.least.one.of.the.magnetic.chucks.controlled.
by. ST200. is. in. magnetization. mode,. the. enabling.
contact.is.closed..PINS.6.and.7.can.be.connected.to.
the.power.of.the.tool.machine.and.used.to.run.the.
enabling.cycles.through.the.controller:.the.controller.
can.only.run.the.cycles.when.PINS.6.and.7.are.closed..Connect.the.safety.catch.to.the.operating.machine.on.which.the.TECNOMAGNETE..module.is.installed.
DB9.PIN.connector
5 4 3 2 1
9 8 7 6
ENABLE ENABLE
MACHINE CONTROLLER pin.n°.1.
➜ B1
.
pin.n°.2.
➜ A2 pin.n°.3.
➜ Vdc pin.n°.4.
➜ Gnd pin.n°.5.
➜ Alarm pin.n°.6.
➜ COM.ENABLE.Controller
pin.n°.7.
➜ ENABLE.Controller
pin.n°.8.
➜ COM.ENABLE.machine
pin.n°.9.
➜ ENABLE.machine
When.possible,.it.is.advisable.to.use.both.types.of.
contacts.
Instruction and maintenance manual 45
6
..
OPTIONALS
6.1 Starting the ST100 controller
ST100.models.can.be.fitted.with.an.optional.external.
start.button,.connected.with.means.of.a.male/female.
connector.
When.the.magnetic.chuck.is.controlled.by.the.ST100.
controller,. it. is. magnetized,. which. means. that. the.
controller.enabling.contact.is.closed
The.technical.specifications.for.the.contact.are:
•.30V.voltage,.1A.current
•.110V.voltage,.0.3A.current
It.is.generally.advisable.to.use.an.auxiliary.relay.
Before.using.other.models.of.start.systems,.contact.
TECNOMAGNETE.S.p.A..for.assistance.
7
..
PLC
Model.ST100.is.not.fitted.with.a.PLC.interface.that.
can.be.used.for.control.purposes.
Model.ST200.has.a..PLC.interface.that.is.constituted.
by.an.external.housing.that.has.to.be.connected.to.
the.controller.by.means.of.the.DB9.connector..The.
interface.is.constituted.by.a.DB37.pin.connector.designed.to.be.interfaced.with.the.control.system.and.
used.to.receive.the.magnetization/demagnetization.
enabling.controls,.to.increase.and.reduce.the.magnetization. levels. and. to. provide. indications. on. the.
machine.status.
The.function.of.available.contacts.is.described.below.
6.2 Push-button panels of models ST100 and ST200
ST100.controllers.can.be.fitted.with.an.optional.twolevel. push-button. panel. for. milling. and. grinding.
chucks.
Model.ST200.can.instead.be.fitted.with.an.optional.
2-level. push-button. panel. for. milling. and. grinding.
operations.and.with.a.7-level.push-button.panel.
It.is.also.possible.to.remotely.connect.all.models.of.
push-button.panels.(basic,.2-level,.7-level).
6.3 QE version
On.models.QE.it.is.possible.to.use.an.optional.external.teleruptor.with.a.power.rating.compliant.to.the.
one.printed.on.the.nameplate.of.the.connected.magnetic.chuck..Said.teleruptor.must.be.installed.in.accordance.with.the.instructions.provided.on.the.electric. wiring. diagram. supplied. with. the. equipment..
This. device. ensures. a. more. efficient. control. of. the.
electric.commands.through.the.machine.
46 Instruction and maintenance manual
19 1
Pin
26
27
28
29
30
31
32
33
34
35
36
37
21
22
23
24
25
17
18
19
20
7
8
9
5
6
3
4
1
2
10
11
12
12
14
15
16
37 20
Name nc nc
Vext
Vext
Vext
Rif.
Rif.
Rif.
Mag
Demag.
COM
NO2
Level.8
COM
NO2
Wait
Alarm
Ld3
Ld5
Out2
Out1
Level.1
Level.2
Level.3
Level.4
Level.5
Level.6
Level.7
SW.Mag
SW.Demag
SW.Level.+
SW.Level.-
Abilit.PLC
Input.Enable
nc.
nc.
nc.
Direction Description
Magnetization.button
Demagnetization.button
Button.that.increases.the.magnetization.level
Button.that.decreases.the.magnetization.level
Enabling.input.for.PLC.management
Input-Enable.input
Not.connected
Not.connected.
Not.connected.
1st.level.magnetization.output
2nd.level.magnetization.output
3rd.level.magnetization.output
4th.level.magnetization.output
5th.level.magnetization.output
6th.level.magnetization.output
7th.level.magnetization.output
8th.level.magnetization.output
Normally.open.common.contact.Out-Abilit
Normally.open.contact.Out-Abilit
Output,.cycle.in.progress
Alarm.output
Not.used
Not.used
Not.used
Not.used
Not.connected
Not.connected
Common contact for buttons Mag, Demag, Level+, Level-
Insulated.24Vdc.(power.supply.provided.by.customer)
Insulated.24Vdc.(power.supply.provided.by.customer)
Common contact for output statuses
Insulated.0V.(reference.to.customer.power.supply)
Insulated.0V.(reference.to.customer.power.supply)
Magnetization.status.output
Demagnetization.status.output
Normally.open.common.contact.Out-Abilit
Normally.open.contact.Out-Abilit
Instruction and maintenance manual 47
48
8
.
CONNECTION TO THE
TECNOMAGNETE MODULE
8.1 Installation of miller ST100
Magnetic.
module
Connector
8.2 Installation of grinder ST100
Magnetic.
module
Discharge.cable
Controller
Power.supply
Cable.tie
Controller
Discharge.cable
Power.supply
Instruction and maintenance manual
.
8.3 Installation of miller ST200
.
.
Installation of
1 chuck
.
Magnetic.chuck
Controller
ST200
.Power.supply
.Push-button.panel..
.CH.ENABLE.push-button.panel.
.Enabling
.Discharge
.Discharge
.PLC.interface
.ON/OFF
.4.PIN.connector
.7.PIN.connector
.Junction.box
Installation of
3 chucks
Controller
ST200
Magnetic.chucks.
.
Installation of
2 chucks
.
Magnetic.chucks
Controller
ST200
Installation of
4 chucks
Magnetic.chucks.
.
Controller
ST200
Instruction and maintenance manual 49
8.4 Installation of grinder ST200
Installation of
1 chuck
.
.
.
Magnetic.chuck
.
.
Controller
ST200
.
.
.Power.supply
.Push-button.panel.
.CH.ENABLE.push-button.panel.(optional).
.Enabling
.Discharge
.Discharge
G .Discharge
.Discharge
.PLC.interface
.ON/OFF
Installation of
3 chucks
Controller
ST200
Magnetic.chucks
Installation of
2 chucks
Magnetic.chucks
Controller
ST200
Installation of
4 chucks
Magnetic.chucks
Controller
ST200
50
Instruction and maintenance manual
9
.
ORDINARY USE
9.1 ST100
To.start.the.ST100.controller,.follow.this.procedure:
1) .. Connect.
the.
discharge.
cable.
to.
TECNOMAGNETE’s.module.
2) . Connect.the.plug.of.the.power.cable.to.the.230V.
electric. socket. and. connect. the. connector. to.
the.magnetic.chuck,.where.available.
3) . Switch.the.ST100.controller.on.using.the.switch.
on.the.rear.of.the.controller.
4) .. Verify.that.the.LEDs.on.the.push-button.panel.
turn.on.
5) .. Press.the.demagnetization.button.(DEMAG).
Note: for.ST100.(base).and.ST100.(version.with.
2.levels).simultaneously.press.buttons.ENABLE.
and.DEMAG.
6) .. Verify. that. the. LED. above. the. DEMAG. button.
turns.on.
7) . Press.the.magnetization.button.(MAG).
Note: for.ST100.(base).and.ST100.(version.with.
2.levels).simultaneously.press.buttons.ENABLE.
and.FULL-MAG.
8) .. Verify. that. the. LED. above. the. MAG. button.
switches.on.
9) .. Verify.that.the.module.is.magnetized.
10) . Start. working. remembering. to. close. the. connector.and.check.the.status.of.the.chuck.after.
every.magnetization/demagnetization.cycle.
7) .. Press.the.magnetization.button.(MAG).
Note: for.ST200.(base).and.ST200.(version..with.
2.levels).simultaneously.press.buttons.ENABLE.
and.FULL-MAG..For.ST200.(version.with.7.levels).simultaneously.press.buttons.ENABLE.and.
MAG.
8) .. Verify. that. the. LED. above. the. MAG. button.
switches.on.
9) .. Verify.that.the.module.is.magnetized.
10) . If.the.discharge.cable.has.been.removed,.start.
the. working. cycle. remembering. to. close. the.
connector.and.check.the.status.of.the.chuck.at.
the.end.of.each.magnetization.and.demagnetization.cycle.
WARNING
Do not place the discharge connector near or in the presence of liquids, flammable material or any other hazardous material.
9.2 ST200
To.start.ST200.controllers,.follow.this.procedure:
1) . Connect.
the.
discharge.
cable.
to.
TECNOMAGNETE’s.module.
2) .. Connect.the.plug.of.the.power.cable.to.the.electric. socket. and. connect. the. connector. to. the.
magnetic.chuck,.where.available.
3) .. Switch. the. ST200X. controller. on. using. the.
switch.on.the.front.of.the.controller.
4) .. Verify.that.the.LEDs.on.the.push-button.panel.
turn.on.
5) .. Press.the.demagnetization.button.(DEMAG).
Note: for. ST200. (base),. ST200. (version. with. 2.
levels).and.ST200.(version.with.7.levels).simultaneously.press.buttons.ENABLE.and.DEMAG.
6) .. Verify. that. the. LED. above. the. DEMAG. button.
turns.on.
Instruction and maintenance manual 51
10
...
ANALYSIS OF RESIDUAL
RISKS
11
MAINTENANCE
11.1 Premise
..
In designing the chuck, the manufacturer has taken into account specific manufacturing criteria and all applicable and current safety requirements, which do not however eliminate other potential residual risks.
This chapter provides a description of the potential risks that could arise in specific situations.
• As the controller is designed to be used to control TECNOMAGNETE modules that are generally installed on tool machines, it is essential to make sure that operators have read and are familiar with the instructions provided in this manual, in the manual of the module and of the tool machine on which the module is installed. Operators must also be made aware of any other potential residual risk.
• The individual protection means that have to be used when working with the chuck are the same ones required for the use of the tool machine on which the module is installed.
• As for the potential residual risks originating from the exposure to electromagnetic fields, specific precautions should be taken by pregnant women; users suffering from specific pathologies; users with pacemakers or other prosthesis with electronic circuits including hearing aids, intracranial metal implants (or any other implant situated next to vital anatomic structures), vascular clips or chips in ferromagnetic material. It is useful to remember that:
1. TECNOMAGNETE magnetic systems are stationary systems and do not generate electric fields.
2. The V/m (Volt/meter) value generated during operation is equivalent to 0 (ZERO).
3. The electromagnetic emissions generated during the enabling/disabling phase does not exceed 100 Gauss at a distance of 100 mm from the system.
52
An.appropriate.maintenance.is.essential.to.maintain.
the.unit.in.good.working.order.for.a.long.period.of.
time,.to.ensure.excellent.performances.and.to.guarantee.its.functional.safety.
11.2 Maintenance safety instructions
ATTENTION power.supply.
...
All. maintenance. operations. must. be. performed. by.
qualified.personnel.only.(see.Chapter.1.7)..
While. performing. maintenance. operations,. always.
take.into.account.the.following:
•. All.maintenance.operations.should.be.performed.
when.the.unit.is.idle.and.disconnected.from.the.
•. All.reparations.on.electric.systems.must.be.performed. after. disconnecting. the. system. from. the.
power. supply. and. enabling. the. emergency. button.. All. personnel. responsible. for. the. operation,.
maintenance.and.cleaning.of.the.unit.shall.have.to.
thoroughly.follow.the.safety.instructions.applicable.to.the.country.of.installation.
•. Always. wear. safety. gloves. and. shoes. and. any.
other.type.of.PPE.required.including.overalls.that.
cover.as.much.of.the.body.as.possible.
•. Do. not. wear. rings,. watches,. chains,. bracelets,.
loose.clothing,.etc..during.maintenance.work.
•. Stand. on. a. rubber. insulating. mat. (if. possible).
when.doing.maintenance.work.
•. Avoid.working.on.wet.floors.or.under.very.damp.
conditions.
•. Always.perform.maintenance.operation.according.
to.schedule.
•. Always. replace. components. with. original. spare.
parts. in. order. to. guarantee. maximum. performance.
•. When.performing.cleaning.operations,.avoid.using.grinders.or.abrasive,.corrosive.or.solvent.material.that.could.cause.the.removal.and/or.make.
numbers,.initials.or.information.printed.on.the.unit.
illegible.
•. Never.wet.the.unit.
•. Clean.all.electric.parts.with.a.vacuum.system.only,.
not.with.compressed.air.
Instruction and maintenance manual
11.3 Weekly maintenance
These.operations,.which.have.to.be.carried.out.by.
the. operator. at. the. end. of. the. weekly. production,.
shall.include:
•. Inspection.of.the.indicator.lights;
•. Inspection.of.the.buttons...
11.4 Monthly maintenance
These.operations,.which.are.based.on.a.daily.working.shift.of.8÷10.hours.and.must.be.performed.by.
qualified.and.skilled.personnel.only,.include:
•. Visual.inspection.of.the.terminal.boards,.the.magnetic.chucks.and.the.controllers;
•. Visual.inspection.of.the.cables.and.plugs...
11.5 Maintenance to be carried out every six months
These.operations,.which.are.based.on.a.daily.working.shift.of.8÷10.hours.and.must.be.performed.by.
qualified.and.skilled.personnel,.include:..
•. Disconnection. of. the. discharge. cables. of. the.
magnetic.chucks.from.the.connection.boxes;
•. Measurement.of.the.resistance.and.insulation.values.at.500V;
•. Reconnection.of.the.discharge.cables.of.the.magnetic.chucks.to.the.connection.boxes.
11.6 Extraordinary maintenance
Maintenance.operations.not.specifically.described.in.
this. manual. are. considered. extraordinary. maintenance.and.must.be.carried.out.by.qualified.personnel. specifically. authorized. by. TECNOMAGNETE.
S.p.A...
11.7 Information on extraordinary reparation and maintenance
The.sections.that.follow.provide.a.dimensional.layout.and.assembly.instructions.for.each.chuck.model.
to.simplify.troubleshooting.
TECNOMAGNETE. S.p.A.. can. be. contacted. at. any.
time.for.further.information.or.queries.regarding.the.
operation.and.maintenance.of.the.controller.
Instruction and maintenance manual 53
12
...
TROUBLESHOOTING AND
CORRECTIVE ACTIONS
This.section.provides.information.designed.to.help.
operators.to.troubleshoot.and.correct.the.problems.
that.may.arise.during.the.use.of.the.equipment.
For.information.on.how.to.solve.problems.related.to.
electric.issues,.see.the.enclosed.diagrams.and.the.
operation. and. maintenance. manuals. supplied. with.
the.controller.
All.reparation.on.electric.components.must.be.carried. out. only. after. disconnecting. the. unit. from. the.
power. supply. and. enabling. the. emergency. button..
All. personnel. responsible. for. reparation. operations.
must.thoroughly.follow.the.accident.prevention.procedures.in.force.in.the.country.of.installation.of.the.
unit.
Problem
The.LEDs.
do.not.turn.
on.when.the.
switch.is.
pressed.
Cause
Disconnected.
power.cable
Corrective action
Switch.the.
controller.off.
and.inspect.
the.connections.using.the.
wiring.diagram.
as.reference.
No.voltage
Verify.that.
voltage.is.
present.
The.LEDs.
do.not.turn.
on.when.the.
switch.is.
pressed.
The.controller.
performs.the.
required.cycle,.
but.does.not.
magnetize.the.
chuck.
Disconnected.
discharge.
cable
Inspect.the.
connections.
13
..
DECOMMISSIONING AND
DISPOSAL
13.1 Decommissioning
The. unit. should. always. be. disconnected. from. the.
power.supply.and.disassembled.from.the.tool.machine.on.which.it.is.installed.if.it.is.not.likely.to.be.
used.for.extended.periods.of.time.
13.2 Dismantling
The.user.is.responsible.for.the.demolition,.dismantling.and.disposal.of.the.materials/components.that.
are.part.of.the.unit..Said.operations.shall.have.to.be.
carried.out.in.accordance.with.UE.directives.or.with.
the.laws.in.force.in.the.country.of.use.
Dismantling.operations.must.always.be.carried.out.
with.utmost.care.to.ensure.maximum.safety.and.prevent. potential. industrial. accidents.. Specific. care.
should.be.taken.when.performing.the.following.operations:
•. Disassembly.of.the.unit.in.the.installation.site.
•. Dismantling.of.the.unit.
•. Separation.of.the.materials/components.that.are.
part.of.the.unit.
Demolition.and.disposal.operations.should.be.carried.out.in.compliance.with.appropriate.regulations.
in.order.to.protect.the.health.of.workers.and.the.environment..In.particular.all.separation,.recycling.and.
disposal.operations.must.be.compliant.with.the.provisions.stated.in.the.national.or.regional.laws.concerning.the.disposal.of.solid.industrial.and.toxic.and.
dangerous.waste..Said.provisions.apply.in.particular.
to:
•. Sleeves,. flexible. ducts. and. plastic. or. non. metal.
parts.must.be.disposed.of.as.special.waste.
•. Electric.components.such.as.switches,.transformers,.sockets,.etc..must.be.disassembled.so.that.
they.can.be.reused,.if.in.good.conditions,.or.inspected.and.recycled.
54 Instruction and maintenance manual
14
..
WARRANTY AND
TECHNICAL SUPPORT
14.2 Invalidity of warranty
14.1 Warranty terms and conditions
TECNOMAGNETE. products. are. guaranteed. for. 36.
months.from.the.date.of.manufacture.except.where.
otherwise.indicated.in.writing..Said.warranty.covers.
all. defects. of. materials. and. workmanship.. Faulty.
parts.shall.be.replaced.or.repaired.by.the.manufacturer.in.his.workshops.
All.material.to.be.repaired.must.be.sent.CARRIAGE.
PAID.
After. reparation,. the. controller. shall. be. sent.
CARRIAGE.FORWARD.to.the.customer.
The. warranty. does. not. cover. expenses. relating. to.
our. engineers. visiting. the. installation. site. nor. machine.dismantling..If.on-site.assistance.is.required,.
labor.cost.shall.be.invoiced.at.current.prices,.along.
with.transfer.and.travel.expenses.
The.manufacturer.shall.not.be.responsible.for.direct.
or.indirect.damages.caused.to.people.or.property.by.
this. controller. or. by. reparations. carried. out. by. the.
purchaser.or.third.parties.
Reparations.under.warranty.shall.not.affect.the.duration.of.the.warranty.period.
This.warranty.does.not.cover:
•. Malfunctions.caused.by.incorrect.use.or.fitting
•. Damages.originating.from.the.use.of.spare.parts.
other.than.those.recommended
•. Damages.caused.by.oxidation.
The.warranty.shall.not.apply.in.the.following.cases:
•. If.the.customer.fails.to.make.the.payments.at.due.
time.or.fulfill.contractual.obligations
•. If. unauthorized. reparations. or. alterations. are.
made
•. If. the. serial. number. has. been. tampered. with. or.
deleted
•. If. the. damage. originates. from. improper. operations.or.use;.for.example.improper.maintenance,.
impacts.and.other.causes.that.cannot.be.attributed.to.ordinary.operating.conditions
•. If.the.controller.has.been.disassembled,.tampered.
with.or.repaired.without.the.written.authorization.
of.TECNOMAGNETE.S.p.A.
All controversies originating from this warranty shall be settled by the Court of Milan.
For.help.or.further.information,.contact.our.technical.
services.department.at.the.following.address:
TECHNICAL SUPPORT SERVICE
®
TECNOMAGNETE S.p.A.
Via Nerviano, 31 - 20020 Lainate (Mi) - ITALY
.
Tel..+39-02.937.59.208.-.Fax..+39-02.937.59.212
Instruction and maintenance manual 55
15
.
TECNOMAGNETE
1
SUPPORT CENTERS
MAIN OFFICE - ITALY
TECNOMAGNETE SpA
Via.Nerviano,.31
20020.Lainate.-.Italy
Tel..+39.02937591
Fax.+39.0293759212
FRANCE - BELGIUM - LUXEMBOURG
TECNOMAGNETE SARL
52.Av..S..Exupéry
01200.Bellegarde.Sur.Valserine
Tel..+33.450.560.600.(FRANCE)
Fax.+33.450.560.610
GERMANY - AUSTRIA - HUNGARY
SWITZERLAND - SLOVAKIA -
THE NETHERLANDS
TECNOMAGNETE GmbH
4.Ohmstraße
63225.Langen.(GERMANY)
Tel..+49.6103.750730.
Fax.+49.6103.7507311
PORTUGAL
SOREP
Rua.Nova.Da.Comeira,.4
2431-903.MARINHA.GRANDE.(PORTUGAL)
Tel..+351.244572801
Fax.+351.244572801
SPAIN
DTC TECNOLOGIA
Poligono.Osinalde.-.Zelai.Haundi,1
20170.USURBIL.(SPAIN)
Tel..+34.943.376050
Fax.+34.943.370509
SWEDEN - NORWAY - DENMARK
FINLAND - BALTIC REPUBLICS
TECNOMAGNETE AB
16.Gustafsvagen
63346.Eskilstuna.(SWEDEN)
Tel..+46.016.132200
Fax.+46.016.132210
56
U.S.A. - CANADA - MEXICO
TECNOMAGNETE Inc.
6655.Allar.Drive,.Sterling.Hts,.MI.48312
Tel.:.+1.586.276.6001.
Fax:.+1.586.276.6003
BRAZIL
COMASE Com. e Prest. de Serv. Ltda
Av..J..Alvez.Correa.3608,.
Jd..Planalto,.Valinhos.-.SP-.CEP.13270-400
Fone/.Fax:.+55.(19).3849-5384
JAPAN
TECNOMAGNETE Ltd.
1-9-7.Shibaura,.
Minato.-.KU
105-0023.Tokyo
Tel..+81.3.5765.9201
Fax.+81.3.5765.9203
CHINA
TECNOMAGNETE R.O.
Pudong.Lujiazui.Dong.road.161,.
SHANGHAI-.Room.2110.-.PC:.200120.
Tel:.+86.21.68882110
Fax.+.86.21.58822110
SINGAPORE - SOUTH-EAST ASIA - ASIA PACIFIC
TECNOMAGNETE Singapore R.O.
101.Thomson.Road.26.-.02.United.Square
Singapore.307591
Tel:.+65.6354.1300..
Fax.+65.6354.0250
Instruction and maintenance manual
Tecnomagnete S.p.A.
Sede Legale in Milano, P.le Cadorna 10
Sede Operativa ed Amministrativa in Lainate (Mi), via Nerviano 31 - 20020 Italy
DICHIARAZIONE DI CONFORMITA’
LA SOTTOSCRITTA DITTA:
DELARATION OF CONFORMITY
THE FIRM
TECNOMAGNETE SPA
V ia
N erviano
31
20020 – LAINATE (MI) ITALY
DICHIARA SOTTO LA PROPRIA RESPONSABILITÀ CHE:
LE UNITA’ DI CONTROLLO
ELETTRONICHE
DECLARES ON IT’S OWN RESPONSABILITY :
THE ELECTRONIC CONTROL UNITS
Modelli/Models
“ST 100 / 200”
AL QUALE QUESTA DICHIARAZIONE SI RIFERISCE È
CONFORME ALLE SEGUENTI NORME O ALTRI DOCU-
MENTI NORMATIVI:
• DIRETTIVA 89/336 CEE (COMPATIBILITÀ
ELETTROMAGNETICA) E SUCCESSIVE
MODIFICHE ED INTEGRAZIONE
•
DIRETTIVA BASSA TENSIONE 73/23
TO WHICH THIS DECLARATION REFERS CONFORMS
WITH THE REQUIREMENTS OF THE FOLLOWING
DIRECTIVES:
• DIRECTIVE 89/336 CEE (ELECTO
MAGNETIC COMPATIBILITY) AND
FOLLOWING AMENDMENTS
•
LOW TENSION DIRECTIVE 73/23
SONO STATE UTILIZZATE LE SEGUENTI NORME E
SPECIFICHE TECNICHE:
THE GROUP ALSO CONFORMS WITH THE
FOLLOWING STANDARDS AND TECHNICAL
SPECIFICATIONS:
EN 61000-6-4 ; EN 61000-6-2 ; EN 61000-4-3 ; EN 55011
THE LEGAL REPRESENTATIVE
MICHELE CARDONE
....................................
SIGNATURE AND STAMP OF AUTHORIZED PERSON
14.01.2005
• IT
TECNOMAGNETE S.p.A.
20020 Lainate (MI)
Via Nerviano 31
Tel. +39 02.937.591
Fax +39 02.935.708.57 [email protected] www.tecnomagnete.com
• FR
TECNOMAGNETE S.A.R.L.
52 avenue Saint-Exupéry
01200 Bellegarde-sur-Valserine
Tel. +33.450.560.600
Fax +33.450.560.610
• DE
TECNOMAGNETE GmbH
Ohmstraße 4, D - 63225 Langen
Tel. +49 6103 750 730
Fax +49 6103 750 7311
• SE
TECNOMAGNETE AB
Gustafsvagen 16
633 46 Eskilstuna
Tel. +46 016 132 200
Fax +46 016 132 210
• US
TECNOMAGNETE Inc.
6655 Allar Drive,
Sterling Hts, MI 48312
Tel. +1 586 276 6001
Fax +1 586 276 6003
• JP
TECNOMAGNETE Y.K. Ltd.
Omodaka Building 1F
1-9-7 Shibaura, Minato-ku
105-0023 Tokyo
Tel. +81 (0)3-5765-9201/02
Fax +81 (0)3-5765-9203
• CN
TECNOMAGNETE Shanghai R.O.
Pudong Lujiazui Dong road 161,
Room 2110 - PC: 200120
Tel. +86 21 68882110
Fax + 86 21 58822110
• SG
TECNOMAGNETE Singapore R.O.
101 Thomson Road 26 - 02 United Square
Singapore 307591
Tel: +65 6354 1300
Fax +65 6354 0250
Download
Advertisement
Key features
Precise control over the magnetic force
Digital display of the magnetic force
Built-in safety features
Compatibility with a variety of magnetic chuck models
Easy installation and operation
Rugged construction
Frequently asked questions
The ST100 series is a line of electronic control systems designed for magnetic chucks.
The ST100 series offers a range of benefits, including precise control over the magnetic force applied to the chuck, digital display of the magnetic force for easy monitoring, built-in safety features to prevent accidental demagnetization, and compatibility with a variety of magnetic chuck models.
The ST100 series is ideal for a variety of applications, including machining, grinding, welding, and assembly.
The ST100 series is easy to install and operate. Please refer to the user manual for detailed instructions.