Timeguard LEDBHR25ELB Instructions
Timeguard LEDBHR25CB is a 25W LED eyelid bulkhead light, suitable for restricted external applications. It offers high lumen output (1100 lumens) and energy efficiency (Class A). The IP65 rating ensures protection against dust and water jets. Installation requires qualified electrician and involves connecting the 230V mains supply cable through the cable entry points.
Advertisement
Advertisement
25W LED Eyelid
Bulkhead Light
Model: LEDBHR25ELB – Silver
1
1. General Information
These instructions should be read carefully and retained for further reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the luminaire is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the installation of this luminaire and install in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This luminaire is of class I construction and must be earthed
• 25W LED non replaceable lamp
• Energy Efficiency: Class A
• Energy Usage:
• Lumen Output:
• Colour Temperature:
26.5KwH/1000H
1100lm
5000K
• IP65 Rated suitable for restricted external applications
• CE Approved
• Dimensions:
• Mounting Hole Centres:
220mm x 220mm x 80mm
155mm
2
4. Installation
• Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit breaker turned OFF.
• An isolating switch should be installed to the switch the power ON and OFF to the luminaire. This allows the unit to be easily switched OFF for maintenance purposes.
• Remove the front of the unit by undoing the 4 Allen bolts (a 2.5mm Allen key is required), remove the bezel and lens with gasket.
• Mark the position of the mounting holes on the wall using the unit as a template and drill the holes ensuring not to infringe with any gas/water pipes or electrical cables that may be hidden below the surface. Insert the rawl plugs into the holes.
• Undo the cable gland sufficiently to allow the 230V 50Hz mains supply cable to be pushed through the back.
• Pass the 230V 50Hz mains supply cable through the cable entry points on the wall plate, ensuring the grommet(s) is used to maintain the IP rating of the luminaire.
• Leave enough slack to allow for wiring, re-tighten the cable gland.
• Fix the luminaire using the correct screws for the wall plugs installed.
• Terminate the cable into the terminal block (See section 5. Connection Diagram) ensuring correct polarity is observed and that all bare conductors are sleeved.
• Secure the supply cable using the cable clamp.
• Reposition the lens over the unit, taking care to ensure the gasket is in place.
• Secure the lens and bezel back into place using the 4 Allen bolts previously removed at the beginning of the installation.
5. Connection
3
MAINS
SUPPLY
Live (Brown or Red)
Neutral (Blue or Black)
Earth (Green/Yellow)
N
L
ISOLATION
SWITCH
E
L
N
6. Operation
Turn the power and the unit will illuminate.
N L
4
3 Year Guarantee
In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge.
For years 2 and 3 or any difficulty in the first year, telephone the helpline on 020 8450 0515.
Note: A proof of purchase is required in all cases. For all eligible replacements
(where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent.
If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline;
HELPLINE
020 8450 0515
or email helpline
@
timeguard.com
Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Office: 020 8452 1112 or email csc
@
timeguard.com
www.timeguard.com
67-058-542 (Issue 1)

Public link updated