CE test report

CE test report
Page 1 of 30
Report No. SEC-07-38
TEST REPORT
IEC 60 065
Audio, video and similar electronic apparatus
Safety requirements
Report Reference No........................ : SEC-07-38
Tested by (+ signature)...................... : wangxin
Approved by (+ signature) ................. : wangying
Date of issue ...................................... : 2007-09-18
Contents ............................................. : 30 pages
Testing laboratory Name................. : Safety and EMC Testing Center of Electronic Industry
Address .............................................. : No. 1 Andingmen Dongdajie Beijing China
Testing location .................................. : as above
Client Name....................................... : Gembird Electronics Ltd.
Address .............................................. : 2F, B Bulding, Shifeng Science and technology Park, Huaning Road,
Xinwei Village Dalang Street, Longhua, Bao An, Shenzhen, China
............................................................ :
Standard............................................. : IEC 60065_2001
Test procedure .................................. : CB-scheme
Non-standard test method ................. : N.A.
Test Report Form/blank test report
Test Report Form No. ........................ : IEC60065D
TRF originator. ................................... : BEAB
Master TRF ........................................ : reference No. 60065/2001
Copyright @ 2002 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE),
Geneva, Switzerland. All rights reserved.
This publication may be produced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright
owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader’s
interpretation of the reproduced material due to its placement and context
Test item Description ........................ : Multimedia Speaker 2.1 system
Trademark.......................................... : Gembird
Model and/or type reference.............: WCS-222
Manufacturer ...................................... : Gembird Electronics Ltd.
Address………………………….....:
2F, B Bulding, Shifeng Science and technology Park, Huaning Road,
Xinwei Village Dalang Street, Longhua, Bao An, Shenzhen, China
Factory………………………………:
Address……………………………..:
Gembird Electronics Ltd.
2F, B Bulding, Shifeng Science and technology Park, Huaning Road,
Xinwei Village Dalang Street, Longhua, Bao An, Shenzhen, China
Rating(s)............................................. : ~220-240V,50/60Hz,18W+10W*2
............................................................ :
TRF No: IEC60065D
TRF originator BEAB
Page 2 of 30
Report No. SEC-07-38
Test case verdicts
Test case does not apply to the test object.................. : N(.A.)
Test item does meet the requirement .......................... : P(ass)
Test item does not meet the requirement .................... : F(ail)
Testing
Date of receipt of test item ........................................... : 2007-08-13
Date(s) of performance of test………………………:
2007-08-20 to 2007-09-14
General remarks
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by a NCB, in accordance with IECEE 02.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
"(see appended table)" refers to a table appended to the report.
“(see remark #)” refers to a remark appended to the report.
“(see Annex #) refers to an annex appended to the report.
Throughout this report a comma (point) is used as the decimal separator.
Summary of Testing and Conclusions
The sample(s) tested complies with the requirements of IEC 60065_2001
Additional information
1. The model name is WCS-222
2. All tests were performed on model WCS-222 to represent the other similar models.
3. Power supply cord set (except VDE certificate, see appended table 14) was not check in this report.
Compliance has to be checked at final installation.
TRF No: IEC60065D
TRF originator BEAB
Page 3 of 30
Report No. SEC-07-38
Copy of marking plate
TRF No: IEC60065D
TRF originator BEAB
Page 4 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
3
GENERAL REQUIREMENTS
P
Safety class of the apparatus ................................. : Class II equipment
P
4
GENERAL CONDITIONS OF TESTS
P
4.1.4
Ventilation instructions require the use of the test
box
5
MARKING
5.1
Result - Remark
Verdict
According to instruction
P
P
Comprehensible and easily discernible
At the rear of the enclosure
P
Permanent durability against water and petroleum
spirit
Durable against the rubbing
test
P
Identification, maker, model ................................... : Refer to copy of marking plate
P
Class II symbol if applicable
P
Double square symbol on label
Rated supply voltage and symbol .......................... : ~220-240V
P
Frequency if safety dependant
P
50Hz/60Hz
Rated current or power consumption .................... : Rated power: 18W+10W*2,
measurement see table 7.1
P
Earth terminal
Class II equipment
N
Hazardous live terminals
No hazardous live terminals
N
Supply output terminals (other than mains)
No supply output terminals
N
5.3
Use of triangle with exclamation mark
In circuit scheme
P
5.4
Instructions for use
P
5.4.1
Mains powered equipment not exposed to dripping Statement in the user’s manual
or splashing. Warning concerning objects filled
with liquid, etc.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N
Instructions for replacing lithium battery
No lithium battery
N
Instructions for modem if fitted
No modem
N
Class I earth connection warning
Class II equipment
N
5.2
Instructions for multimedia system connection
5.4.2
P
Special stability warning for fixed installation
Not fixed installation
N
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
Statement in the user’s manual
P
Instructions for permanently connected equipment Not permanently connected
equipment
TRF No: IEC60065D
N
TRF originator BEAB
Page 5 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
6
HAZARDOUS RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
6.2
Laser radiation, emission limits to IEC 60825-1 .... : No laser radiation
N
Emission limits under fault conditions .................... :
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified values, (see appended table)
no operation of fuse links
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as (see appended table)
a mechanical barrier
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
o
mains carrying a current > 0,2 A at least 150 C
(see appended table)
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
No hazard
P
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
No hygroscopic materials used
as insulation
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
No a cover which can be
removed by hand
N
8.5
Class I equipment
Class II equipment
N
8.6
Result - Remark
Verdict
N
No ionizing radiation
N
Basic insulation between hazardous live parts and
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.2.1 a)
N
Class II equipment and Class II constructions
within Class I equipment
P
Reinforced or double insulation between
hazardous live parts and accessible parts
TRF No: IEC60065D
Reinforced or double insulation
P
TRF originator BEAB
Page 6 of 30
Report No. SEC-07-38
IEC 60065
Clause
8.7
8.8
8.9
8.10
Requirement – Test
Result - Remark
Verdict
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
See sub-clause 14.3
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
N
Basic insulation bridged by components complying
with 14.3.4.3
N
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
N
Separation by Class II isolating transformer
N
Separation by Class I transformer
N
Separation by earthed conductive part
N
Basic or supplementary insulation > 0,4 mm (mm) :
P
Reinforced insulation > 0,4 mm (mm) .................... : Thickness of bobbin of
transformer: 0.9mm
P
Thin sheet insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
N
Adequate insulation between internal hazardous
live conductors and accessible parts
Inside wire>0.4mm
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
Inside wire>0.4mm
P
Double insulation between conductors connected
to the mains and accessible parts
TRF No: IEC60065D
P
TRF originator BEAB
Page 7 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.11
Detaching of wires
Connected reliable
P
No undue reduction of creepages or clearance
distances if wires become detached
N
Vibration test carried out ........................................ : No
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
No mains socket-outlet
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
No windows, lenses, etc
N
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
No risk of damage
P
8.16
Only special supply equipment can be used
Not special supply equipment
N
8.17
Insulated winding wire without additional
interleaved insulation
No insulated winding wire
N
8.18
Endurance test as required by 8.17
No insulated winding wire
N
8.19
Disconnection from the mains
8.19.1
Disconnect device
P
P
Plug and switch
P
All-pole switch or circuit breaker with >3mm
contact separation
N
8.19.2
Mains switch ON indication
P
8.20
Switch not fitted in the mains cord
8.21
Bridging components comply with clause 14
N
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
N
9.1.1.1
U1: 1.614Vpeak
Touch current measured from terminal devices
using the network in annex D ................................. : U2: 0.311Vpeak
P
Discharge not exceeding 45 µC
P
Energy of discharge not exceeding 350 mJ
N
9.1.1.2
Test with test finger and test probe
TRF No: IEC60065D
No switch fitted in mains cord
Hazardous live parts not
accessible
P
P
TRF originator BEAB
Page 8 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
9.1.2
No hazardous live shafts of knobs, handles or
levers
No hazardous live shaft
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
Won’t touch hazardous
parts
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
Won’t touch hazardous
parts
P
9.1.5
Pre-set controls tested with 2 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
No pre-set controls
N
9.1.6
No shock hazard due to stored charge on
No capacitor in primary circuit.
withdrawal of the mains plug; voltage (V) after 2 s :
N
If C is not greater than 0,1 µF no test needed
N
9.1.7
Enclosure sufficiently resistant to external force
Verdict
P
P
No damage after below tests
P
Test probe 11 of IEC 61032 for 10 s (50 N)
P
Test hook of fig. 4 for 10 s (20 N)
P
30 mm diameter test tool for 5 s (100 or 250 N) .... :
P
9.2
No hazard after removing a cover by hand
No removable cover by hand
10
INSULATION REQUIREMENTS
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
N
10.2
Humidity treatment 48 h or 120 h ........................... : 120h 40 ℃ ,93%RH
P
10.3
Insulation resistance and dielectric strength
P
11
FAULT CONDITIONS
P
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
P
(see appended table)
N
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
(see appended table)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
Temperature rise of PCB not
exceeding the limits of table 3
N
TRF No: IEC60065D
TRF originator BEAB
Page 9 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
N
Class I protective earthing maintained
Class II equipment
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
(see appended table)
P
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass >7 kg
12.1.2
Vibration test
12.1.3
Impact hammer test
No damage
P
Steel ball test
No damage
P
P
6.5kg
N
P
12.1.4
Drop test for portable apparatus where mass < 7
kg
N
12.1.5
Thermoplastic enclosures strain relief test
12.2
Fixing of knobs, push buttons, keys and levers
12.3
Remote controls with hazardous live parts
No remote control
N
12.4
Drawers (pull test 50 N, 10 s)
No drawer
N
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial sockets
N
12.6
Telescoping or rod antennas construction
N
12.6.1
Telescoping or rod antennas securement
N
13
CLEARANCE AND CREEPAGE DISTANCES
P
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
Main enclosure is made of
wood
N
P
13.2
Determination of operating voltage
Considered
P
13.3
Clearances
See appended table
P
TRF No: IEC60065D
TRF originator BEAB
Page 10 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
P
13.4
Creepage distances
See appended table
P
Creepage distances greater than table 11 minima
P
13.5
Printed boards
P
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
P
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
No type B coated printed circuit
boards used
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
None
N
Conductive parts along reliably cemented joints
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
None
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
None
N
14
COMPONENTS
P
14.1
Resistors
N
14.2
a) Resistors between hazardous live parts and
accessible metal parts
None
N
b) Resistors, other than between hazardous live
parts and accessible parts
None
N
b) Resistors separately approved .......................... : None
N
Capacitors and RC units
N
Capacitors separately approved
N
14.2.1
Y capacitors tested to IEC 60384-14, 2 edition .. : None
N
14.2.2
X capacitors tested to IEC 60384-14, 2 edition .. : None
N
14.2.3
Capacitors operating at mains frequency but not
None
connected to the mains: tests for X2 ..................... :
N
nd
nd
TRF No: IEC60065D
TRF originator BEAB
Page 11 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
14.2.5
Capacitors with volume exceeding 1750 mm³,
Capacitor with volume is not
3
where short-circuit current exceeds 0,2 A:
exceeding 1750mm
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
N
Shielded by a barrier to V-0 or metal ..................... : No barrier used
N
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
P
Transformers and inductors marked with
See appended component list
manufacturer's name and type .............................. :
P
Transformers and inductors separately approved . :
N
14.3.2
General
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
P
14.3
14.3.1
Coil formers and partition walls > 0,4 mm
Result - Remark
Verdict
Thickness of formers of
transformer: 0.9mm.
P
partition walls:1.1mm
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.3
Separating transformers with at least basic
insulation
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
P
Coil formers and partition walls > 0,4 mm
Class II transformer
Thickness of formers of
transformer:0.9mm
N
P
partition walls:1.1mm
TRF No: IEC60065D
TRF originator BEAB
Page 12 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II transformer
Winding wires connected to protective earth have
adequate current-carrying capacity
14.4
High voltage components
N
N
No such component
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
N
14.5
Protective devices
P
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-outs
b) Thermal cut-outs tested as part of the
submission
14.5.1.2
a) Thermal links separately approved
N
N
See appended component list
b) Thermal links tested as part of the submission
P
N
14.5.1.3
Thermal devices re-settable by soldering
None
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
See appended component list
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : F1,F0.5A/250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
N
PTC-S devices (15 W) category V-1 or better
N
14.5.4
Circuit protectors have adequate breaking capacity No such circuit protectors
and their position is correctly marked
provided
N
14.6
Switches
P
TRF No: IEC60065D
See appended component list
TRF originator BEAB
Page 13 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
14.6.1 a)
Separate testing to IEC 61058 including:
Result - Remark
Verdict
P
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
No socket outlet
N
Socket outlet current marking correct
Safety interlocks
14.8
N
No safety interlock
N
Safety interlocks to 2.8 of IEC 60950
N
Voltage setting devices
N
Voltage setting device not likely to be changed
accidentally
N
14.9
Motors
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
TRF No: IEC60065D
No motors
N
TRF originator BEAB
Page 14 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
14.10
Batteries
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
N
14.10.3
Recharging currents and times within
manufacturers limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
N
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11
Optocouplers
14.12
Result - Remark
Verdict
N
No batteries
N
No optocoupler
N
Optocouplers comply with Cl. 8
N
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
N
Surge suppression varistors
No surge suppression varistor
N
Comply with IEC 61051-2
N
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
N
15
TERMINALS
P
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
Mains plug
P
No such symbol of 5.2
N
15.1.3
Output terminals of a.c. adaptors or similar devices No output terminals of a.c
not compatible with household mains socketadaptors or similar devices
outlets
N
15.2
Provision for protective earthing
N
TRF No: IEC60065D
TRF originator BEAB
Page 15 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
Class II equipment
N
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
N
Protective earth terminal resistant to corrosion
N
Earth resistance test: < 0,1 Ω at 25 A ................... :
N
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
P
15.3.1
Adequate terminals for connection of permanent
wiring
N
15.3.2
Reliable connection of non-detachable cords:
P
Not soldered to conductors of a printed circuit
board
P
Adequate clearances and creepage distances
between connections should a wire break away
P
Wire secured by additional means to the conductor
N
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
N
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
P
Clamping of conductor and insulation if not
soldered or held by screws
P
15.3.5
Terminals allow connection of appropriate crosssectional area of conductors, for the rated current
of the equipment
P
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
N
Terminals designed to avoid conductor slipping out
when tightened or loosened
N
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N
TRF No: IEC60065D
TRF originator BEAB
Page 16 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
P
Terminals located and shielded: test with 8 mm
strand
N
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
N
15.4.2
Device complies with standard for dimensions of
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
N
16
EXTERNAL FLEXIBLE CORDS
P
16.1
Mains cords sheathed type, complying with
Power supply cord set was
IEC 60227 for PVC or IEC 60245 for synthetic
certificated by VDE
rubber cords ............................................................ :
P
Non-detachable cords for Class I have
green/yellow core for protective earth
N
16.2
Mains cords conductors have adequate crosssectional area for rated current consumption of the
equipment
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
Not direct-plug equipment
Class II
N
P
No interconnection cord
N
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
N
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N
16.5
Adequate strain relief on external flexible cords
P
Not possible to push cord back into equipment
P
Strain relief device unlikely to damage flexible cord
P
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
N
TRF No: IEC60065D
TRF originator BEAB
Page 17 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
No risk of damage
P
16.7
Transportable apparatus fitted with detachable
cord set with appliance inlet to IEC 60320-1
Not transportable apparatus
N
Transportable apparatus fitted with detachable
cord sets or with means of stowage to protect the
cord
N
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
P
17.1
Torque test to table 20:
P
- screws into metal: 5 times
N
- screws into non-metallic material: 10 times
1.2Nm for cover fixing
P
17.2
Correct introduction into female threads in nonmetallic material
P
17.3
Cover fixing screws: captive
P
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A
N
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
N
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
No cover fixing devices
N
17.8
Fixing devices for detachable legs or stands
provided
No detachable legs and stands
N
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
Connection reliable.
P
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
N
Picture tube separately approved to IEC 61965:
N
18.1
No picture tube
Picture tube separately approved to 18.1 ...............
N
Picture tubes > 16 cm intrinsically protected
N
TRF No: IEC60065D
TRF originator BEAB
Page 18 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
Non-intrinsically protected tubes > 16 cm used with
protective screen
N
18.2
Intrinsically protected tubes: tests on 12 samples
N
18.2.1
Samples subject to ageing: 6
N
18.2.2
Samples subject to implosion test: 6
N
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
N
18.3
Non-intrinsically protected tubes tested to 18.3
N
19
STABILITY AND MECHANICAL HAZARDS
P
Mass of the equipment exceeding 7kg .................. : <7kg
P
Apparatus intended to be fastened in place –
suitable instructions
N
Not intended to be fastened in
place
o
19.1
Test on a plane, inclined at 10 to the horizontal
N
19.2
100 N force applied vertically downwards
N
19.3
Apparatus mass > 25 kg or height > 1 M or
supplied with cart or stand
Not such apparatus
N
19.4
Edges or corners not hazardous
Edges and corners of
enclosure are rounded
P
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
None
N
19.6
Wall or ceiling mountings adequate
None
N
20
RESISTANCE TO FIRE
P
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
N
b) Exemption for small components as defined in
20.1
considered
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
See sub-clause 14 and
appended table
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
<4kV
N
TRF No: IEC60065D
TRF originator BEAB
Page 19 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
See appended component list
P
Material of printed circuit boards on which the
<400V
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
P
Components and parts as above but shielded from No barrier used
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N
20.2
Fire enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
N
20.1.4
TRF No: IEC60065D
<4kV
N
TRF originator BEAB
Page 20 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
N
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
N
A.10.2.1
Enclosure provides protection against splashing
water
N
A.10.2.2
Humidity treatment carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
N
Complies with IEC 62151 clause 1
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
TRF No: IEC60065D
Result - Remark
Verdict
TRF originator BEAB
Page 21 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
P
Position of the functional switch (W) ......................: 0
—
Operating conditions
-100Hz sine-wave to the audio-input terminal, 1/8 of the non-clipped output power to the impedance
Un (V)
In (A)
Pn (W)
Pout (W)
50Hz
60Hz
50Hz
60Hz
264
0.13
0.14
16
18
--
240
0.09
0.09
13
14
--
220
0.07
0.08
10
10
--
198
0.06
0.06
9
9
--
Loudspeaker impedance (Ω) ............ 4Ω+4Ω
Several loudspeaker systems
--
Marking of loudspeaker terminals
--
—
Monitored point:
dT (K)
Limit dT (K)
50Hz
60Hz
Supply Voltage
198V
264V
198V
264V
--
T1 metal enclosure
14.6
19.8
15.0
19.3
--
T1 core
14.4
17.6
14.0
19.4
85
T1 coil
9.9
13.1
9.8
14.7
75
C24
11.8
12.7
10.7
15.9
--
Input wire in primary
3.1
3.8
3.1
3.8
60
Output wire in secondary
5.5
6.2
5.3
7.2
60
Inside of enclosure
5.3
5.3
5.2
5.6
60
Outside of enclosure
6.3
7.4
6.5
9.1
60
PCB
27.4
31.7
25.9
38.2
85
Heat sink
19.6
23.3
18.7
27.7
--
Winding temperature rise measurements
P
o
Ambient temperature t1 ( C) ...................................: 23.0
—
Ambient temperature t2 ( C) ...................................: 26.2 (198V,50Hz)
25.8 (198V,60Hz)
25.7 (264V,50Hz)
25.6 (264V,60Hz)
—
o
TRF No: IEC60065D
TRF originator BEAB
Page 22 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
7.1(con.)
TABLE: temperature rise measurements
Temperature rise dT of winding:
Result - Remark
Verdict
P
R1 (Ω)
R2 (Ω)
dT (K)
Limit dT (K)
Insulation
class
Transformer coil (primary)
198V,50Hz
64.3
69.1
16.0
85
--
Transformer coil (primary)
264V,50Hz
64.3
70.8
23.3
85
--
Transformer coil (primary)
198V,60Hz
64.3
69.2
16.8
85
--
Transformer coil (primary)
264V,60Hz
64.3
71.2
25.0
85
--
7.2
TABLE: softening temperature of thermoplastics
Temperature T of part
N
T - normal condio
tions ( C)
T - fault condio
tions ( C)
T softening
o
( C)
Switch and voltage setting device are separately approved.
10.3
TABLE: insulation resistance measurements
Insulation resistance R between:
P
R (MΩ)
Required R (MΩ)
Between L—N
>100
≥2
Between mains poles and terminal
>100
≥4
Between primary and secondary coil of transformer
>100
≥4
10.3
TABLE: electric strength measurements
Test voltage applied between:
P
Test voltage (V)
Breakdown
Between L—N
1500Vac
No
Between mains poles and terminal
3000Vac
No
Between primary and secondary coil of transformer
3000Vac
No
Between primary coil and core of transformer
3000Vac
No
TRF No: IEC60065D
TRF originator BEAB
Page 23 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
11.2
TABLE: summary of fault condition tests
Result - Remark
Verdict
P
fault condition, state component short- or open circuited supply Result, state effect of fault condition and the
and components whose temperature rises are
voltag duration of the test
measured
e (V)
No. component
fault
Temperature
Test
Result
duration
measured(℃)
264
3min
Input current: 0.09A-0.61A-0A,
1 C30
s
T1 core:26.2
F1 opened,D1 damage,
T1 coil:31.2
No excessive temperature rises.
PCB:7.2
No hazard.
Enclosure:2.1
2
C37
s
--
264
30min
Input current:0.09A . normal
operation. No excessive
temperature rises.No hazard.
3
C53
s
--
264
30min
Input current:0.09A . normal
operation. No excessive
temperature rises.No hazard.
4
C51
s
--
264
30min
Input current:0.09A . normal
operation. No excessive
temperature rises.No hazard.
5
C13
s
--
264
30min
Input current:0.09A . normal
operation. No excessive
temperature rises.No hazard.
6
R41
s
--
264
30min
Input current:0.09A . normal
operation. No excessive
temperature rises.No hazard.
7
D4
s
--
264
<1s
Input current :0.09A -0A., F1
opened, No excessive
temperature rises.No hazard.
8
Left output
s
T1 core:41.5
T1 coil:44.1
PCB:37.5
Enclosure:23.9
264
3h
Input current :0.09A –0.17A.,
output stopped, No excessive
temperature rises.No hazard.
9
IC10(1-2)
s
T1 core:51.7
T1 coil:53.3
PCB:41.9
Enclosure:25.4
264
3h
Input current :0.09A –0.22A., not
normal operation, No excessive
temperature rises.No hazard.
10
C40
s
--
264
<1s
Input current :0.09A -0A., F1
opened, No excessive
temperature rises.No hazard.
s:short circuit
TRF No: IEC60065D
TRF originator BEAB
Page 24 of 30
Report No. SEC-07-38
IEC 60065
Clause
13
Requirement – Test
Result - Remark
Verdict
TABLE: clearance and creepage distance measurements
Clearance(cl) and
creepage distance(dcr)
at/of:
Transformer primary to
secondary coil
L and N
TRF No: IEC60065D
Up(V)
Ur.m.s.(V)
Required
cl(mm)
P
Cl(mm)
Required
dcr(mm)
Dcr(mm)
387
264
4.0
14.2
5.1
17.8
339
240
2.0
12.7
2.5
12.7
TRF originator BEAB
Page 25 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
14
TABLE: list of critical components and materials
Component
Flexible Cord
Result - Remark
Manufacturer/
trademark
Type/model
Verdict
P
Value / rating
2
Yuyao Jingyi Electronics H03VVH2-F 2X0.75 mm
Co., Ltd.
Standard
VDE0281- VDE (133957)
5
Volex (Asia) Pte. Ltd.
Mains Plug
Approval/
Reference
VDE
(103704)
Yuyao Jingyi Electronics JY-001
Co., Ltd.
2,5A 250V~
Volex (Asia) Pte. Ltd.
2,5A 250V~
M4206
EN 50075
VDE
(40008181)
VDE
(137417)
PCB
KINGBOARD
LAMINATES LTD.
KB-3151
Fuse
Shenzhen Lanson
Electronics Co. Ltd.
3JFxxx250V F0.5A/250V
EN 60127- VDE
1
(40009301)
Switch
YUEQING GOLDEN
ANCHOR
ELECTRONIC
ELECTRIC INDUSTRY
CO.
SW-2
5A/40A 250V~
GB15092. CQC03002005
1625
2003(IEC
61058 )
Transformer
T1
SHENZHEN BAOAN
XINXINDA
ELECTRONIC
FACTORY
EI57
Class B
IEC
Tested within
60065:200 appliance
1
Bobbin
E I DUPONT DE
NEMOURS & CO INC
/
130°C, 94V-2
--
NAN YA PLASTICS
CORP
/
130°C, 94V-2
UL(E130155)
GUANGZHOU KINGFA
SCIENCE &
TECHNOLOGY CO
LTD
/
130°C, 94V-2
UL(E171666)
JINGJIANG YAHUA
PRESSURE
SENSITIVE GLUE CO
LTD
PZ-28
130°C
FOSHAN INDER
ADHESIVE
PRODUCTS CO LTD
24D
(F1)
Tape
TRF No: IEC60065D
94V-0, 130°C
UL94
--
UL (E123995)
UL(E41938)
UL(E165111)
UL(E212612)
TRF originator BEAB
Page 26 of 30
Report No. SEC-07-38
IEC 60065
Clause
Requirement – Test
Component
Primary
winding /
Secondary
winding
Secondary
leadout
/Primary
leadout
Thermal link
used in
transformer
Manufacturer/
trademark
Result - Remark
Type/model
Value / rating
Verdict
Standard
Approval/
Reference
130°C
UL
130°C
UL
130°C
UL
HUIYANG GOLDEN
OCEAN MAGNET
WIRE FACTORY
2UEW
SHENZHEN DAYANG
INDUSTRY CO LTD
2UEW
GUANGDONG
RONSEN SUPER
MICRO-WIRE CO LTD
2UEW
DONGGUAN SHIPAI
LICHENG
ELECTRONICS CO
UL1015
AWG22,105°C
LEE YUEN
ELECTRICAL MFY
UL1015
AWG22,105°C
Xiamen Set Electronics
Co.,Ltd
RH
115°C, 2A, 250V
IEC 60691 200201020500
9194
Aupo Electronics Ltd.
A2
115°C, 2A, 250V
IEC 60691 UL (E140847)
VDE
(40008720)
TRF No: IEC60065D
(E225143)
(E176101)
(E164502)
--
UL
(E205058)
UL
(E137515)
TRF originator BEAB
Page 27 of 30
Report No. SEC-07-38
Sample photo:
Front of REVO-3
side of REVO-3
TRF No: IEC60065D
TRF originator BEAB
Page 28 of 30
Report No. SEC-07-38
back of REVO-3
Inside of REVO-3
TRF No: IEC60065D
TRF originator BEAB
Page 29 of 30
Report No. SEC-07-38
Inside of REVO-3
TRF No: IEC60065D
TRF originator BEAB
Page 30 of 30
Report No. SEC-07-38
circuit scheme
TRF No: IEC60065D
TRF originator BEAB
Was this manual useful for you? yes no