MicroCal 20 series - Yantrika Instruments Pvt Ltd

MicroCal 20 series - Yantrika Instruments Pvt Ltd
eurotron
“Excellence in measurements”
MicroCal 20 series
Documenting process calibrators
• Dual readout for measure and source
• mA,V, RTD’s,TC’s frequency measure/source
• HART® ability
• Measure pressure from -1 to 700 bar
• ATEX approved to II 1 G EEx ia II C T4
• RS 232 interface and fully documenting version
Eurotron - A world leaders in high technology equipment: portable flue gas analysers- high accuracy calibrators- non-contact IR thermometers
MicroCal 20 series
Documenting Pr ocess Calibr at ors
The MicroCal 20 series documenting process
calibrators are rugged hand tools for calibration,
maintenance and trouble shooting of virtually all
the control process instrumentation.
The IS versions are certified to ATEX II 1 G EEx ia
II C T4, and suitable for use in hazardous area.
The series include three different models from a
basic version to a sophisticated XP model.
Combined with the both internal and external
pressure modules, MicroCal 20’s IS can calibrate
almost any process parameter likely to need
service in the area where explosive gases are
present.
These calibrator feature
• Calibrate temperature, pressure, voltage,
frequency and resistance
• Dual channel display for simultaneous
measure/source
• Measure and source 14 types of thermocouple
and 10 RTD’s
• 24 Vdc loop power supply (12 Vdc for IS)
• Connection for internal and external pressure
module up to 700 bar
• Pressure switch test and leak test
• Rechargeable battery and charger
• Hold, zero, scale, Min/Max/AVG, Tare and flow
• Automatic Ramp/Step with programmable
time, step and dwell
CAPABILITIES
mA, V, RTDs, T/C’s, Hz, ⍀
Measure/Source
Dual channel display
Dual input
Internal pressure module
Remote Pressure sensor
Loop power supply
HART® communicator
Documenting capability
20
20 Plus
20-IS 20 Plus-IS
•
•
•
•
•
•
•
•
•
•
•
•
20 XP
20 XP-IS
•
•
•
•
•
•
•
•
•
MULTI-FUNCTION PROCESS CALIBRATOR
The easy to operate
menu driven software
enable the MicroCal
20’s to be set very
quickly. Easily scroll
trough the input and
output menu to select
the required parameter.
TEMPERATURE TRANSMITTER SIMULATION
Direct connection of thermocouple
compensated wires and advance cold junction
compensation offer unbeatable accuracy.
When calibrating a temperature transmitter,
MicroCal 20’s simulate the temperaure signal
to the transmitter and simultaneously
measures the output. Both the mA and mV
are displayed in C for easy comparison. By
running a documenting procedure, the pass/fail status can be
display on the calibrator. The 24 VDC loop power is provided
(12 VDC for IS version)
ELECTRICAL CONNECTION
Standard banana plugs
Mini isothermic TC’s connector
Push & lock system for bare wires
2, 3 and 4 wire for RTD connections
MicroCal 20/20-IS
Multi-function Process Calibrator with data logging
facility
The cost effective choice for technicians and
engineer that don’t require full documenting
capability. This basic version offer all the feature of
a multi-function calibrator and can measure
pressure up to 700 bar via the Eurotron “Plug &
Play” remote pressure sensor.
MicroCal 20 Plus/20 Plus-IS
Full documenting process calibrator with built-in
pressure module
The intermediate model of the series which offer
an excellent value for money for plant technicians
and engineers who require a full documenting
process calibrator with the Pass/Fail on board test
results. The MicroCal 20 plus offer an extended
accuracy to 0.01% of reading for the electrical
signal and can measure pressure both with
internal pressure sensors and remote pressure
module. The optional CalPman documenting
software allow to create, upload and download
calibration procedure for printing report and data
analysis.
MicroCal 20 XP/20 XP-IS
Extended feature with HART® ability
The XP version, top of the range, offer all the
features of the Plus model, and the ability to
calibrate, maintain and trouble shooting HART®
instrumentation, including pressure and
temperature transmitter. In addition, the unit offers
a dual channel inputs. It supports customised
PRT’s curve for enhanced temperature
measurement.
LOOP CHECKING AND READ OUT DEVICE CALIBRATION
MicroCal 20s can generate a continuous signal,
Step or Ramp output allowing a single technician
to commission control loops. The mA and Voltage
output can be scaled in % of FS or in engineristic
unit for direct comparison. The scaling can be
selected to be either linear or square for flow
meter readout device.
MicroCal 20 series
HAR T Ability and Pressure Capability
POWERFUL DOCUMENTING CAPABILITY
CALPMAN 2006 CALIBRATION SOFTWARE
The Powerful CalPman 2006 software package helps to
comply with the burned imposed by the quality system such
as the ISO 9000. As the Calibration procedure is filled, object,
tags and procedure are downloaded to the MicroCal. In the
Field these procedure configure the calibrator and the
Pass/Fail data are stored as “as found” and “as left”data for
later uploaded to the PC. The whole documenting process is
completed in minutes
MicroCal 20 Plus/20 Plus-IS and 20 XP/
20 XP-IS add powerful time saving and
error eliminating to the comprehensive
functionality of the MicroCal 20. These
include field error calculation with the
Pass/Fail report. The calibrator
calculates Pass/Fail status on field for
an immediate assessment and
correction greatly reducing calibration
time and eliminating human error.
AUTOMATED TEMPERATURE CALIBRATION
HART® ABILITY
The internal Hart communicator feature available as standard on the
MicroCal 20 XP/20 XP-IS versions replace the need for a separate
hand held communicator, greatly reducing HART® transmitter
maintenance and Calibration time. Universal command, such as tags
and serial number and specific command such as sensor trimming or
adjustment are available depending of the type of transmitter. Please
refer to the web page or contact a local representative for the list of
compatible transmitter which cab be continuously updated by a
simple download from our web page. Once connected to HART®
device, the MicroCal digitally communicate and provide the 250 ohm
loop resistance.
The MicroCal 20 XP can be
used as an high accuracy dual
channel thermometer for
temperature sensor
calibration. It supports
customised SPRT for
enhanced temperature
measurement. Simply CH1
and CH2 are used both as
input to provide a direct
comparison between a
Reference sensor and a probe
under test. When the T
module procedure is selected, MicroCal 20 XP is also able to drive offline the Eurotron or other manufacturers’ temperaure calibrator baths to
perform a full automated temperature calibration procedure. Please
contact us for the list of supported temperature calibartor.
Pressure Capability
The extreme flexibility of MicroCal 20’s/20 IS’s can be
extended by adding pressure capability to the unit up to
700 bar. MicroCal 20’s can be expanded to read
pressure by using “ Plug & Play” remote pressure
module or by adding up to two Internal pressure sensors
to the main unit (Plus/Plus-IS and XP/XP-IS versions).
The wide choice of ranges, both absolute and gauge
with typical accuracy of 0.025 % FS offer a cost
effective solution of extending the MicroCal 20’s/20
IS’s capability to:
•
•
•
•
•
Calibration of pressure transmitter
Test of pressure switches
Pressure measurement
I-P converter testing
Flow measurement calibration
Advance Eurotron technology and their performance are
stored inside each pressure module enabling convenient
use of any MicroCal 20’s/20 IS’s without recalibration.
Pressure range and specification, see next page.
TRANSMITTER CALIBRATION
Simply configure MicroCal 20’s/20-IS’s to
simultaneously display the output pressure and
input current or Voltage. The Pressure units can
be chosen to suit the transmitter, and the 24VDC
loop power is available (12 VDC limited for IS
version).
The external PGS pump series can generate
pressure from -.800 to 700 bar and fine
adjustment gives fine pressure setting. For
Process transmitter the current or voltage
reading can be scaled/converted in % of Span or in
engenierstic unit for easy comparison.
HART® pressure device can be calibrated with the
MicroCal 20 XP/XP-IS.
By selecting current out put and pressure reading,
MicroCal 20’s/20-IS simply perform calibration of I-P
converter, typical 4-20 to 3-15 PSI.
Option A1 & A2
internal sensor
Option B1
remote sensor
SWITCH TEST AND LEAK FINDING
The advance task menu, configure
MicroCal 20’s to display the
output pressure and he the switch
state OPEN/CLOSE. The display
will capture the change of status,
which will be shown along with
the Hysteresis of the switch. Data
can be stored for later recal.
LEAK TEST function will check
for leaks during routine
maintenance or process
measurement. Leak time, waiting
time are fully programmable. The
MicroCal 20’s will report the
Initial and the final pressure, the
change and the leak rate. Press
Store to save the data.
MicroCal 20 series
TECHNICAL SPECIFICATION (ELECTRICAL)
Specification
Parameter
Range or Type
Temperature measure and source
T/C’s
J*, K*, T*, U, L, N
T/C’s
R, B,C,G,D,F,E
RTD’S
Pt100, 1000 (385)
Pt100, (3926), Pt100 (3902)
Pt200, Pt500, Cu10
Cu100, Ni100, Ni120
Resolution
Accuracy
20/20-IS
Accuracy
20 Plus-IS/XP-IS
Features
Temperature unit
C, F or K selectable
Temperature scale
ITS 90 or IPTS 68 selectable
0.01°C
0.1°C
±(0.02% rdg.+0.1°C)
±(0.02% rdg.+0.1°C)
±(0.01% rdg.+0.1°C)
±(0.01% rdg.+0.1°C)
0.01°C
0.01°C
0.1°C
0.1°C
±(0.02% rdg.+0.05°C)
±(0.02% rdg.+0.05°C)
±(0.02% rdg.+0.1°C)
±(0.02% rdg.+0.05°C)
±(0.01% rdg.+0.05°C)
±(0.01% rdg.+0.05°C)
±(0.02% rdg.+0.1°C)
±(0.02% rdg.+0.05°C)
1 ␮V
10 ␮V
100 ␮V
±(0.02% rdg.+3 ␮V )
±(0.02% rdg.+10 ␮V)
±(0.02% rdg.+100 ␮V)
±(0.01% rdg.+3 ␮V )
±(0.01% rdg.+10␮V)
±(0.01% rdg.+100 ␮V)
0.1 ␮A
0.1 ␮A
±(0.02% rdg.+0.4 ␮A)
±(0.02% rdg.+0.4 ␮A)
±(0.01% rdg.+0.4 ␮A)
±(0.01% rdg.+0.4 ␮A)
10 m⍀
100 m⍀
±(0.02% rdg.+12 m⍀)
±(0.02% rdg.+120 m⍀)
±(0.01% rdg.+12 m⍀)
±(0.01% rdg.+120 m⍀)
Electrical measure and source
Voltage
-20 to 200 mV
-2 to 2 V
-2 to 20 V (11 VDC-IS)
Current (in) -5 to 50 mA (30 mA-IS)
(out) 0 to 50 mA*(21 mA-IS)
Resistance
0 to 500 ⍀
0 to 5000 ⍀
Frequency
1 to 200 Hz
0.001 Hz
±(0.005% rdg+ 0.001 Hz) ±(0.005% rdg+ 0.001 Hz)
1 to 2 Khz
0.01Hz
±(0.005% rdg+ 0.0 1Hz) ±(0.005% rdg+ 0.01 Hz)
1 to 20 Khz
0.1 Hz
±(0.005% rdg+ 0.1 Hz) ±(0.005% rdg+ 0.1 Hz)
Pulse
0 to 10(6)
1 count
The relative accuracies shown above are stated for 365 days and the operative conditions are from 18 to
28°C. All input ranges: additional error ±1 digit.
*Resolution is 0.1°C below 200°C.
**21mA/12 VDC max on passive current loop (ATEX)
Note: additional technical information available on the web site.
Pressure specification (optional)
Type Internal option Remote option
(A1/A2)
(B1)
±100 mbar
G
G
G
±500 mbar
G
G
G
-1 to 1 bar
G
G
G
-1 to 2 bar
G or A
G or A
G or A
-1 to 7 bar
G
G
G
-1 to 20 bar G or A
G or A
G or A
-1 to 35 bar
G
G
G
0 to 70 bar
SG
SG
SG
0 to 150 bar
SG
SG
SG
0 to 350 bar
SG
SG
0 to 700 bar
SG
SG
Ramp
Fully programmable with up/down, Tsoak and dwell and cycles
Scaling
6 digits on electrical input/output both liner and square
Signal converter
Covert any input into output (mA or V) fully isolated
Task
Storage and recall of 10 user configuration
Transmitter simulation
mA or V output reads in temperature or pressure unit
Transmitter calibration
Both input and output readings in temperature or Pressure units
Math function
Hold, max, min, offset, zero, average
Data storage
Internal non -volatile memory
Computer interface
Fully bidirectional RS232 (for IS version, in a safe area use only)
Language
Support multi language
Display
MicroCal 20/20-IS version takes only remote pressure sensors (B1), MicroCal 20 Plus-IS
and 20 XP/20XP-IS versions take up two internal sensors (A1-A2) and remote pressure
sensors (B1) the ranges of which need to be specified.
Pressure
Frequency source
Square, triangolar or Sinusoidal with adjustable amplitudine
Accuracy
(1 Year)
0.025% FS
0.025% FS
0.025% FS
0.025% FS
0.025% FS
0.025% FS
0.025% FS
0.025% FS
0.025% FS
0.025% FS
0.025% FS
Resolution
Graphic LCD display
with automatic and manual backlight, 6 digits
Sampling time
250 ms
Environmental
Operating temperaure
-10 to 50°C
0.001 mbar
0.01 mbar
0.01 mbar
0.01 mbar
0.1 mbar
0.1 mbar
1 mbar
1 mbar
1 mbar
10 mbar
10 mbar
Humidity
0 to 95 % non-condensing
Sealing
IP 54
Intrinsically safe version
ATEX approved II 1 G Eex ia II C T4
Power Supply
Internal NI-HM rechargeable battery (charger supplied as standard)-life 10hrs on TC
and mV/V output (IS version, recharge in a safe area only).
Negative pressure (-100 mbar, -500 mbar and -1 bar) are only for gauge ranges.
A = absolute, G = gauge, SG = sealed gauge
Accuracy is defined as non linearity, hysteresis and repeatability
Averaged temperature effect = ±0.002 of rdg/°C (w.t.r + 23°C)
Compensated temperature range 0 to 40°C
Temperature compensation automatic with built-in calibration matrix
Physical
1.4 kg, 290X98X57 mm
Conformity
ISO9000, 89/336/CEE
Pressure sensor media AISI 316 compatible fluids (water, gases and oil)
Overpressure 125 % FS.
Pressure unit: mbar, bar, Pa, hPa, kPa, MPa, kg/cm2, kg/m2, psi, mmH2O, cmH2O, mH2O, Torr, atm, lb/ft2, inH2O,
ftH2O, mmHg, cmHg, mHg, inHg, user defined (1).
Ordering Information
MicroCal 20 Documenting Process Calibartor
MicroCal 20PLUS Documenting Multi-function Calibrator
MicroCal 20XP Documenting Multi-finction Calibrator with HART® and T module
MicroCal 20-IS Process Calibarator, IS version
MicroCal 20PLUS-IS Documenting Process Calibrator, IS version
MicroCal 20XP-IS Documenting Process Calibrator with HART®, IS version
CalpMan2006 Calibration software package (includes USB cable)
Options
Option A1: Internal pressure sensor for XP and Plus versions (specify range and type)
Option A2: Second internal pressure sensor for XP and Plus versions (specify range and type)
Option B1: Remote Pressure Sensor (specify range and type)
Pneumatic and hydraulic hand pump
PGS 3 Pneumatic Pressure Pump
Range: -.850 to 3 bar
Complete with 2 x 1/4 BSP F adaptors and a hose
PGS 40 Pneumatic Pressure Pump
Range: -.950 to 40 bar
Complete with 1/4 BSP F adaptor and a hose
PGS 700 Hydraulic Pressure Pump
Range 0 to 700 bar
Water/Oil operated
HTH-1000 Hydraulic Pressure Hose
1 m high pressure rate flexible hose
Complete with 1/4 BSP F adaptor
Included accessories
MicroCal 20/20PLUS/XP include rubber sleeve, set of test leads, traceable calibration
certificate, rechargeable battery, charger and instruction manual. MicroCal 20XP only
include HART® communicator and HART® user manual
Note: MicroCal 20/20P/X-IS version do not include rubber sleeve.
PGS-BSP-40
A set of BSP adaptors suitable for pneumatic applications
PGS-BSP-700
A set of SS BSP adaptors suitable for hydraulic applications
Accessories
BB880033: Aluminium carrying case
BB880048: Vinyl carrying case
BB880043: Vinyl carrying case with shoulder strap
BB300122: Thermocouple cable kit
Continuous development may necessitate change of specification without notice.
CALIBRATOR
INFRARED
THERMOMETER
eurotron
“Excellence in measurements”
GAS
ANALYSER
EUROTRON Instruments (UK) Ltd.
Unit 1, The Sidings, Bridingbury Rd
Marton, Rugby, Warwicks. CV23 9RX
Tel. +44(0)1926 633 339
Fax +44(0)1926 632 966
[email protected]
www.eurotronuk.com