7 in 1 Talking Infrared Thermometer
Model: TS42S
User's Manual
Please read this instruction manual carefully before using your ear thermometer
For a voice recorded version of this manual please visit www.snotty.com.au/products/thermometers/7in1- talking-thermometer
Index
Introduction
Important Information Before Use
Product Identification and Caution
Description of LCD Display
Setting Volume, °C/°F and Date/Time 5
3
4
1
2
Using the Thermometer
Memory Recall and Deletion
Battery Installation
Trouble-shooting
Storage and maintenance
Technical Specifications
Warranty
Contact
15
16
9
14
17
18
18
19
Introduction
Thank you very much for choosing this product.
Utilizing infrared technology, this thermometer takes temperatures in seconds by measuring heat generated by the surface skin of the forehead or other objects. This product conforms to the provisions of the EC directive
MDD(93/42/EEC).Its advantages include:
1. 7 in 1 thermometer
Ear/Forehead/Talking/Object/Fever light bar/Backlight
Display/Date & Time Stamp
2. Green/Red light for normal/fever alert
This device has the LED light to alert their readings are over
38°C.
3. Illuminated Backlight Display
4. 30-memory Recall
30 sets memory function & easy- to- read LCD (Liquid Crystal
Display) display give convenience all in one finger touch.
5. °C/°F Switchable
o
6.Probe Cover Free
The cover free probe can eliminate the problem of transmission deviation due to the cover's material, and is as such more accurate.
7. Waterproof Probe Design
Waterproof probe enables easy cleaning and usage.
8. One-second Reading
9. Power Saving-Auto Power Off
Auto power-off after 30 second idling to ensure longer battery life.
10.Low-battery Indicator
11.Warning indication
"low battery" symbol, and “Lo"/ "Hi" symbol indicating out of measuring range or low battery.
12.Large LCD Display
Easy to read large LCD display.
13.Large Button Design
For easier operation.
14.Economic design and convenience
This is a “Non-contact” medical thermometer that enables temperature readings in ear, object or subject forehead.
15.Accurate and Reliable
16.Compact
Small and light design is ideal for home- use and traveling.
17.User Friendly
Due to our unique design of the measuring software, users don't need to have special skill to operate this device.
18.Instant Measurement
By using our unique technology, users can get their precise body temperature accurately in 1 second.
19.Conveniently powered by two (AAA) batteries.
1
Important Information Before Use
When using this product, please be sure to follow all instructions listed below. Failure to follow these instructions may affect the accuracy of the thermometer and cause injury.
1. Do not disassemble, repair, or remodel the thermometer.
2. Be sure to clean the thermometer lens before and after each use.
3. Avoid direct finger contact with the lens.
4. No modification of this equipment is allowed.
5. It is recommended to take 3 temperature readings. If they are different, use the highest reading as indicated temperature.
6. Do not expose the thermometer to extreme temperature, very high humidity, or direct sunlight.
7. Avoid extreme shock or dropping the device.
8. Before taking a temperature measurement make sure that both the thermometer and the patient/object have been in the specific environment for at least 30 minutes.
9. Avoid measuring temperatures within 30 minutes after exercise, bath, or change of environment.
10.To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations.
11.Do not disassemble the thermometer.
12.Please use the thermometer solely for its intended purpose.
13.Carefully hold the device when in use to avoid dropping the device.
14.Allow one minute between successive measurements as slight variations may occur if measurements are taken over a short period of time. Use average temperatures instead.
15.Keep reliable records of your personal temperature to serve as a reference for your health professional.
16.The temperature taking result is ONLY a reference.
Before taking any medical action, please consult a health professional.
2
Product Identification and Caution
Sensor tip with lens
(cover cap removed)
Forehead/cover cap
Forehead thermometer mode button (forehead)
Ear thermometer mode/On button (ear)
LED signal red: high temperature alarm green: normal
LCD Display
Memory button
Speaker
Set button
Battery compartment lid
3
Forehead icon
Measurement mode
“Ear”
Measurement mode
“Object”
“ Memory” symbol and storage space number
Description of LCD Display
Date Time
“Measurement in progress” symbol
Unit of measurement (°C)
Unit of measurement (°F)
Measurement display
Speaker symbol
Battery warning symbol
4
Setting Volume, °C/°F and Date/Time
LCD Display
Press the SET button for 5 second
1. Volume
Change the setting
Save the setting and
Confirm the entry
2. °C/°F
Change the setting
Save the setting and
Confirm the entry
3. Date/Time
Change the Year
Save the setting and
Confirm the entry
Month
Change the Month
Save the setting and
Confirm the entry
Date
Change the Date
Save the setting and
Confirm the entry
Hour
Change the Hour
Save the setting and
Confirm the entry
Min
Change the Min
Save the setting and
Confirm the entry
4.
End setting loop, turn off the unit
Save the setting
5
Setting Volume, °C/°F and Date/Time
Setting Volume
The unit in which the temperature will be displayed, the date and the time.
When the thermometer is used for the first time and each time the batteries are changed, the date and time are displayed in the format 1-1 00:00 during the basic set-up (after the self test). Set each of the following settings in turn: volume, unit in which the temperature will be displayed, date and time. To set the device, proceed in stages: Volume (U01 – lowest setting, U06
– highest setting), Unit – year – month – day – hours –
minutes (there is no voice output when setting date and time).
1. Press the SET button for 5 second to switch the thermometer on. The device performs a brief self test: all elements of the display are shown for approx. 1 second.
Following a successful self test, the device emits two short beeps. In Standby mode, the date and time are shown and “--” is displayed.
2. Turn the device on and the speaker symbol shows whether the Volume function is on or off. Press the
"SET" button to turn the Volume function on and off.
When you turn the voice function on, a short beep sounds (speaker symbol visible = voice function on; speaker symbol not visible = voice function off).
Press the “SET” button to change the volume.
• VOL 01
• VOL 02
• VOL 03
• VOL 04
• VOL 05
• VOL 06
3. Press the “MEM” button to confirm entry.
6
Setting Volume, °C/°F and Date/Time
Changing from Fahrenheit to Celsius
1. Press the "SET" button to turn the °C/°F function on and off.
2. Press the “MEM” button to confirm entry.
7
Setting Volume, °C/°F and Date/Time
Date/Time Function
1. Press the “SET” button to change.
2. Press the “MEM” button to confirm entry.
3. The blinking Date, followed by Year, Hour and
Minutes will display. Repeat steps 2 and 3 to adjust the date/time setting.
4. Your unit is now ready to take a reading, or press the
“MEM” button to turn the unit off.
5. After this process, the thermometer shows the word
“OFF” in the display and switches off automatically.
Date/Time
Change the Year
Save the setting and
Confirm the entry
Month
Change the Month
Save the setting and
Confirm the entry
Date
Change the Date
Save the setting and
Confirm the entry
Hour
Change the Hour
Save the setting and
Confirm the entry
Min
Change the Min
Save the setting and
Confirm the entry
End setting loop, turn off the unit
Save the setting
8
Using the Thermometer
Before each use, please check that the lens is intact, cleaned, if damaged, please contact your retailer or the service address. Bear in mind that the thermometer needs to have been in the room in which the measurement is taken for at least 30 minutes before use.
Measuring body temperature in the ear
• Some people produce different readings in their left and right ear. In order to record temperature changes, always measure a person’s temperature in both ears and use the higher reading.
• The ear thermometer may be used by children only under adult supervision. Measurement is usually possible over the age of 6 months. In infants under
6 months, the ear canal is still very narrow so the temperature of the eardrum often cannot be recorded and the result displayed is often too low.
• The measurement must not be taken in an ear affected by inflammatory diseases (e.g. discharging pus or secretion), after possible ear injuries (e.g. eardrum damage) or in the healing period after operative procedures. In all of these cases, please consult your health professional.
• Use of the thermometer on different persons can be inappropriate in the event of certain acute infectious diseases because of the possible spread of germs despite cleaning and disinfection. If you have any doubts, please consult your health professional.
• This thermometer should be used without a disposable protective cover.
• If you have been lying on one ear for some time, the temperature will be slightly higher in that ear.
• As ear wax can affect the measurement, you should clean the ear before measuring if required.
9
Using the Thermometer
Measuring body temperature in the ear
1. Press the EAR button for 1 second to switch the thermometer on. Following a successful self test, the device emits two short beeps.
2. Remove the cap by gently lifting the front of cap upwards (1) while simultaneously pulling it off forward (2).
2 1
3. Make sure that the sensor tip and also the ear canal are clean. As the ear canal is slightly curved, you have to pull the ear slightly up and backwards before inserting the sensor tip. This is important so that the sensor tip can be pointed directly at the eardrum.
4. Insert the sensor tip carefully and press the EAR button for 1 second.
5. Release the EAR button. The end of the measuring time is signaled with a short beep and the measured value appears on the display and is spoken.
10
Using the Thermometer
Measuring body temperature on the forehead
1. Please note that the forehead/temples must be free from sweat and cosmetics and that taking medication and skin irritations can distort the result when measuring temperature on the forehead.
2. Press the HEAD button for 1 second to switch the thermometer on. Following a successful self test, the device emits two short beeps.
3. Place the measuring head with the forehead/cover cap fitted on the temples, hold down the HEAD button and move the thermometer smoothly over the forehead to the other temple.
4. Then release the HEAD button. The end of the measuring time is signaled with a short beep and the measured value appears on the display and will be spoken.
Press Forehead thermometer mode button
11
Using the Thermometer
Measuring surface temperature
1. Press the EAR button for 1 second to switch the thermometer on. Following a successful self test, the device emits two short beeps.
2. Then press the “MEM” and EAR buttons simultaneously for 3 seconds to switch to the Object temperature mode. The symbol appears in the display.
3. Press and hold the EAR button or the HEAD button and point the sensor tip towards the object or liquid to be measured (never immerse in liquids), maintaining a distance of 3 cm.
4. Release the EAR button or the HEAD button. The end of the measuring time is signaled with a short beep and the measured value appears on the display and is spoken.
5. Please note that the displayed temperature is the measured and not the adapted surface temperature.
It is not the same as the forehead/ear temperature.
6. To switch back to the Ear/Forehead thermometer mode, press the “MEM” and EAR buttons simultaneously for 3 seconds until the symbol disappears and there is a short beep. By switching the thermometer off and on again, it automatically exits the Object temperature mode.
Press any
Scan Button
12
Using the Thermometer
The Readings:
Release the button. The end of the measuring time is signalled with a short beep and the measured value appears on the display.
(1) < 38°C: The reading show on LCD, meanwhile the backlight and alert light (green) will light for 3 sec and then the voice will pronounce the temperature.
(2) ≧38°C: The reading show on LCD, meanwhile the backlight and alert light (red) will light for 3 sec and then the voice will pronounce the temperature.
Green
Normal
<38 C
(<100.4 F)
Red
Fever
≧38 C
(≧100.4 F)
When talking on: The Voice Sentence:
Ear: "your body temperature is 36.5°C”
Forehead: "your body temperature is 36.5°C”
Object: "the object temperature is 36.5°C”
When Talking OFF:
The light indicator shows only for 3 seconds.
13
Memory Recall and Deletion
Memory Recall:
You can recall up to 30 measurements plus an average of all currently stored measurements in memory to share with your physician or trained healthcare professional.
1. Press the “MEM” button. The first reading displayed is the average of all measurements stored in memory.
2. Continue to press the “MEM” button to view the next previously stored measurement.
Note: The memory bank can store up to 30 readings.
When the number of readings exceeds 30, the oldest data will be replaced with the new record.
14
Battery Installation
When the batteries get weak, the battery warning symbol appears" ". It is still possible to measure temperature. The batteries must be replaced. When the battery symbol flashes" " and Lo appears in the display, the batteries must be replaced. If the batteries are too flat, then the thermometer will switch off automatically.
NOTE:
• When changing the batteries, use batteries of the same type, make and capacity.
• Always replace both batteries at the same time.
• Do not use rechargeable batteries.
• Please use batteries free from heavy metals.
1. Loosen the screw on the battery compartment lid and pull the lid off downwards.
2. Remove the used batteries and insert two new (AAA) batteries in the direction indicated.
3. Place the battery compartment lid back on and screw it closed.
Dispose of used batteries in accordance with the applicable local regulations. Never dispose of batteries with your normal household waste.
15
Trouble-shooting
When a malfunction or incorrect temperature measurement occurs, an error message will appear as described below (comes with backlight and voice prompt).
LCD Display Cause
The temperature measured is higher than
1. Ear/Forehead
thermometer mode:
50°C (122.0°F)
2. Object temperature mode:
100°C (212.0°F)
The temperature measured is lower than
1. Ear/Forehead
thermometer mode:
10°C (50.0°F)
2. Object temperature mode:
0°C (32.0°F)
The operating temperature is not in the range from
16°C~35°C
(60.8°F~95°F)
Solution
Operate the thermometer only between the specified temperature ranges. If necessary, clean the sensor tip.
In the event of a repeated error message, contact your retailer or
Customer Services.
Operate the thermometer only between the specified temperature ranges.
When talking on:
Prompt: "measurement error, please try again”
16
Storage and maintenance
• Clean the probe and tip with an alcohol swab before and after each measurement.
• Use a soft, dry cloth to clean thermometer body. Never use abrasive cleaning agents, thinners or benzene for cleaning. Do not scratch the surface of the probe lens or the display. Do not expose the thermometer to extreme temperatures, humidity, direct sunlight, or shock.
Store at room temperature.
17
Technical Specifications
• Range of Measurement :
Body Temperature: 10°C ~50°C (50.0°F ~ 122.0°F)
34℃
Object Temperature: 0°C ~ 100°C(32.0°F~212.0°F)
0℃
• Measuring accuracy :
Ear:
43℃
100℃
±0.2°C(0.4°F): from 35.5°C to 42°C (95.9°F to 107.6°F)
42℃
±0.3°C(0.5°F): outside the range
35.5℃
Forehead:
±0.3°C(0.5°F): from 22°C to 40°C (71.6°F to 104°F)
22℃
40℃
Object Temperature: ≦30°C ±1.5°C ;
>30°C ± 5% (in 3cm)
• Operating environment : o o o
16℃
35℃
with relative humidity up to 85% (non condensing)
• Storage/ Transportation environment :
55℃ o o o
-25℃
with relative humidity up to 85% (non condensing) o
• Power supply : 2 X 1.5V AAA size alkaline batteries
• Weight : 65g (with batteries)
• Dimensions : 134.3mm×42.4mm×47.6mm (L×W×H)
• Warranty : Full 12 months warranty from date of purchase. ( Please save your receipt as proof of purchase date)
0197
18
Consult instruction for use
Type BF equipment
The device shall
be disposed in
accordance with national laws after their useful lives
19
EC REP
Wellkang Ltd
29 Harley St.
W1G 9QR
LONDON, U.K.
Manufactured for:
Perpetus Pty Ltd Australia
ABN 49 142811 069
Made in China
SNOTTY
P.O. Box 111
Labrador Qld 4215
Australia web: www.snotty.com.au
email: [email protected]
72-T42MN-031