WaterWorks GUDV2T is a universal two-way diverter valve for thermostatic shower systems, allowing you to control the flow of water to two separate devices, such as a shower head and a handshower. It features non-simultaneous operation, preventing water from flowing out of both devices at the same time. The valve incorporates tactile feedback at each position for precise control. Installation requires pairing with a thermostatic valve (sold separately) and is best performed by a professional licensed contractor.

advertisement

Waterworks GUDV2T Universal Two Way Diverter Valve for Thermostatic Shower Systems Installation Guide | Manualzz

STYLE No. GUDV2T, GU2TDV

Universal Two Way Diverter Valve for

Thermostatic Shower Systems

INSTALLATION GUIDELINES

STYLE NO. GUDV2T, GU2TDV†

IMPORTANT:

 ALL VALVES AND TRIMS SOLD SEPARATELY.

 To ensure this DIVERTER VALVE is installed properly, you must read and follow these guidelines.

 The owner/user of this DIVERTER VALVE must keep this information for future reference.

 This DIVERTER VALVE must be paired with a THERMOSTATIC

VALVE (sold separately).

 This VALVE CANNOT be used with a DIVERTING TUB SPOUT.

 CAUTION: The VALVE rough-in depth is measured from the center of the inlets to the surface of the finished wall and VARIES depending on the TRIM used.

 This DIVERETER VALVE and associated TRIM (SOLD SEPARATELY) must be installed by a professional licensed contractor and must be onsite prior to rough-in. This allows the installer to visualize the installation.

 This DIVERTER VALVE is sold partially assembled but shown fully disassembled for illustrative and service purposes only. Inspect the VALVE to ensure you have all the parts required for proper installation.

 Be sure your installation conforms to all federal, state, and local codes. In the State of Massachusetts, all installations must comply with the rules and regulations set forth within 248 CMR.

PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM

 If further assistance is required, please contact Product Support at 1-800-927-2120 Monday through Friday, 8am – 6pm EST.

 Refer to the separate Service Parts Documents for available replacement parts.

TECHNICAL DETAILS:

DETAIL SPECIFICATION

INLET/OUTLET CONNECTIONS

FITTINGS HOLE DIAMETER

ROUGH-IN DEPTH

UNRESTRICTED MAX FLOW RATE @ 45 PSI [3 bar]

1/2” MALE NPT †

Ø2” [51mm]

VARIES ‡

10gpm [38L/min]

WATER PRESSURE MAXIMUM

WATER PRESSURE MINIMUM

85psi [6.0 bar]

20psi [1.5 bar]

WATER PRESSURE RECOMMENDED 45psi [3.0 bar]

† Style No. GU2TDV is provided with 3 BSPP ADAPTERS. ADAPTERS are packaged separately and assembly is required. Replacement ADAPTERS can be ordered separately:

● Universal 1/2” NPT Female x 1/2” Male BSPP Adapter

Style No. UNUK03

‡ Refer to the Installation Guidelines of the specific DIVERTER VALVE TRIM being used for the

MAXIMUM and MINIMUM rough-in depth dimensions.

PAGE 1 OF 3 | UPDATED ON 10.13.2021

STYLE No. GUDV2T, GU2TDV

Universal Two Way Diverter Valve for

Thermostatic Shower Systems

INSTALLATION GUIDELINES

VALVE FUNCTION AND HANDLE OPERATION:

 CAUTION: When this DIVERTER VALVE is paired with a DIVERTER VALVE TRIM that has specific device MARKINGS, it is crucial that the outlet ports are correctly plumbed to those specific devices (i.e. handshower and shower head)

 The required THERMOSTATIC VALVE (sold separately) only mixes hot and cold water, it does not have an on/ off/ or volume control function. Mixed water flows out at a fixed volume to the DIVERTER VALVE which has

3 positions.

● 2 ON positions that can direct water flow to a

MAXIMUM of 2 devices. Water CANNOT flow out of the devices simultaneously (i.e. out of the shower head AND handshower together).

● 1 OFF position that shuts the water off to all devices.

● The DIVERTER VALVE incorporates tactile feedback at each position.

NON-FUNCTIONAL

OULET

[DO NOT USE]

DEVICE

MARKING

"C"

MIXED

WATER

INLET

[GUDV2T SHOWN]

ROUGH-IN AND VALVE PREPARATION:

 Check incoming water pressure.

 IMPORTANT:

● The VALVE rough-in depth is measured from the center of the inlets to the surface of the finished wall and VARIES depending on the TRIM used.

● Refer to the Installation Guidelines of the specific DIVERTER VALVE TRIM being used for the MAXIMUM and MINIMUM rough-in depth dimensions.

 CAUTION:

● DO NOT APPLY DIRECT HEAT TO THE VALVE.

Pre-solder any connections to prevent damage to the CARTRIDGE and other internal components.

● The DIVERTER VALVE TRIM components (i.e.

HANDLE and TRIM PLATE) may be packaged separately from each other.

CENTER

OF

INLET

“A”

ROUGH-IN

DEPTH

THREADED

TUBE

DEVICE

MARKING

"B"

“B”

FITTINGS

HOLE

TILE GUARD

DEVICE

MARKING

“B”

FINISHED

WALL

DEVICE

MARKING

“OFF”

[HANDLE OPERATION]

DIM

A

B

DEVICE

MARKING

“C”

VALUE

VARIES ‡

Ø2” [51mm]

PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM

PAGE 2 OF 3 | UPDATED ON 10.13.2021

INSTALLATION GUIDELINES

FINI HED

LL

OUNTING

T

LOC ING

RECO ENDED

CENTER LINE

OF INLET

ROUGH-IN

DEPTH

1. The VALVE rough-in depth is measured from the center of the inlets to the surface of the finished wall and VARIES depending on the TRIM used.

* TURN ON WATER SUPPLY AND CHECK FOR LEAKS !

* NOTE: STYLE NO. GU2TDV IS PROVIDED WITH BSPP

ADAPTERS.

DIVERTER

VALVE

[1/2" MALE

NPT THREADS] *

1/2"

COPPER

SUPPLY

2. From the THERMOSTATIC VALVE being used, run a copper supply line to the proper height of the DIVERTER VALVE making sure it’s positioned according to the VALVE MARKINGS so that mixed water flows into the inlet and all piping and fittings are secured.

STYLE No. GUDV2T, GU2TDV

Universal Two Way Diverter Valve for

Thermostatic Shower Systems

* NOTE: STYLE NO. GU2TDV IS PROVIDED WITH BSPP

ADAPTERS.

NON-FUNCTIONAL

OUTLET

[DO NOT USE]

1/2"

COPPER

PIPE

[1/2" MALE

NPT THREADS] *

1/2"

COPPER

PIPE

[1/2" MALE

NPT THREADS] *

3. Run 1/2” copper supply lines from the outlet ports to the 2 desired devices making sure all piping and fittings are secured.

FINISHED WALL

CARTRIDGE

STEM

CARTRIDGE

STEM

4. Turn on the water supply and operate the

CARTRIDGE STEM to flush out the lines and check for leaks.

PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM

[CLOSED]

5. After the supply lines have been fully flushed, turn off the water.

NOTE: Verify all VALVE positions are functioning properly.