Waterworks GUDV2T Universal Two Way Diverter Valve for Thermostatic Shower Systems Installation Guide
Add to My manuals3 Pages
WaterWorks GUDV2T is a universal two-way diverter valve for thermostatic shower systems, allowing you to control the flow of water to two separate devices, such as a shower head and a handshower. It features non-simultaneous operation, preventing water from flowing out of both devices at the same time. The valve incorporates tactile feedback at each position for precise control. Installation requires pairing with a thermostatic valve (sold separately) and is best performed by a professional licensed contractor.
advertisement
STYLE No. GUDV2T, GU2TDV
Universal Two Way Diverter Valve for
Thermostatic Shower Systems
INSTALLATION GUIDELINES
STYLE NO. GUDV2T, GU2TDV†
IMPORTANT:
ALL VALVES AND TRIMS SOLD SEPARATELY.
To ensure this DIVERTER VALVE is installed properly, you must read and follow these guidelines.
The owner/user of this DIVERTER VALVE must keep this information for future reference.
This DIVERTER VALVE must be paired with a THERMOSTATIC
VALVE (sold separately).
This VALVE CANNOT be used with a DIVERTING TUB SPOUT.
CAUTION: The VALVE rough-in depth is measured from the center of the inlets to the surface of the finished wall and VARIES depending on the TRIM used.
This DIVERETER VALVE and associated TRIM (SOLD SEPARATELY) must be installed by a professional licensed contractor and must be onsite prior to rough-in. This allows the installer to visualize the installation.
This DIVERTER VALVE is sold partially assembled but shown fully disassembled for illustrative and service purposes only. Inspect the VALVE to ensure you have all the parts required for proper installation.
Be sure your installation conforms to all federal, state, and local codes. In the State of Massachusetts, all installations must comply with the rules and regulations set forth within 248 CMR.
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM
If further assistance is required, please contact Product Support at 1-800-927-2120 Monday through Friday, 8am – 6pm EST.
Refer to the separate Service Parts Documents for available replacement parts.
TECHNICAL DETAILS:
DETAIL SPECIFICATION
INLET/OUTLET CONNECTIONS
FITTINGS HOLE DIAMETER
ROUGH-IN DEPTH
UNRESTRICTED MAX FLOW RATE @ 45 PSI [3 bar]
1/2” MALE NPT †
Ø2” [51mm]
VARIES ‡
10gpm [38L/min]
WATER PRESSURE MAXIMUM
WATER PRESSURE MINIMUM
85psi [6.0 bar]
20psi [1.5 bar]
WATER PRESSURE RECOMMENDED 45psi [3.0 bar]
† Style No. GU2TDV is provided with 3 BSPP ADAPTERS. ADAPTERS are packaged separately and assembly is required. Replacement ADAPTERS can be ordered separately:
● Universal 1/2” NPT Female x 1/2” Male BSPP Adapter
Style No. UNUK03
‡ Refer to the Installation Guidelines of the specific DIVERTER VALVE TRIM being used for the
MAXIMUM and MINIMUM rough-in depth dimensions.
PAGE 1 OF 3 | UPDATED ON 10.13.2021
STYLE No. GUDV2T, GU2TDV
Universal Two Way Diverter Valve for
Thermostatic Shower Systems
INSTALLATION GUIDELINES
VALVE FUNCTION AND HANDLE OPERATION:
CAUTION: When this DIVERTER VALVE is paired with a DIVERTER VALVE TRIM that has specific device MARKINGS, it is crucial that the outlet ports are correctly plumbed to those specific devices (i.e. handshower and shower head)
The required THERMOSTATIC VALVE (sold separately) only mixes hot and cold water, it does not have an on/ off/ or volume control function. Mixed water flows out at a fixed volume to the DIVERTER VALVE which has
3 positions.
● 2 ON positions that can direct water flow to a
MAXIMUM of 2 devices. Water CANNOT flow out of the devices simultaneously (i.e. out of the shower head AND handshower together).
● 1 OFF position that shuts the water off to all devices.
● The DIVERTER VALVE incorporates tactile feedback at each position.
NON-FUNCTIONAL
OULET
[DO NOT USE]
DEVICE
MARKING
"C"
MIXED
WATER
INLET
[GUDV2T SHOWN]
ROUGH-IN AND VALVE PREPARATION:
Check incoming water pressure.
IMPORTANT:
● The VALVE rough-in depth is measured from the center of the inlets to the surface of the finished wall and VARIES depending on the TRIM used.
● Refer to the Installation Guidelines of the specific DIVERTER VALVE TRIM being used for the MAXIMUM and MINIMUM rough-in depth dimensions.
CAUTION:
● DO NOT APPLY DIRECT HEAT TO THE VALVE.
Pre-solder any connections to prevent damage to the CARTRIDGE and other internal components.
● The DIVERTER VALVE TRIM components (i.e.
HANDLE and TRIM PLATE) may be packaged separately from each other.
CENTER
OF
INLET
“A”
ROUGH-IN
DEPTH
THREADED
TUBE
DEVICE
MARKING
"B"
“B”
FITTINGS
HOLE
TILE GUARD
DEVICE
MARKING
“B”
FINISHED
WALL
DEVICE
MARKING
“OFF”
[HANDLE OPERATION]
DIM
A
B
DEVICE
MARKING
“C”
VALUE
VARIES ‡
Ø2” [51mm]
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM
PAGE 2 OF 3 | UPDATED ON 10.13.2021
INSTALLATION GUIDELINES
FINI HED
LL
OUNTING
T
LOC ING
RECO ENDED
CENTER LINE
OF INLET
ROUGH-IN
DEPTH
1. The VALVE rough-in depth is measured from the center of the inlets to the surface of the finished wall and VARIES depending on the TRIM used.
* TURN ON WATER SUPPLY AND CHECK FOR LEAKS !
* NOTE: STYLE NO. GU2TDV IS PROVIDED WITH BSPP
ADAPTERS.
DIVERTER
VALVE
[1/2" MALE
NPT THREADS] *
1/2"
COPPER
SUPPLY
2. From the THERMOSTATIC VALVE being used, run a copper supply line to the proper height of the DIVERTER VALVE making sure it’s positioned according to the VALVE MARKINGS so that mixed water flows into the inlet and all piping and fittings are secured.
STYLE No. GUDV2T, GU2TDV
Universal Two Way Diverter Valve for
Thermostatic Shower Systems
* NOTE: STYLE NO. GU2TDV IS PROVIDED WITH BSPP
ADAPTERS.
NON-FUNCTIONAL
OUTLET
[DO NOT USE]
1/2"
COPPER
PIPE
[1/2" MALE
NPT THREADS] *
1/2"
COPPER
PIPE
[1/2" MALE
NPT THREADS] *
3. Run 1/2” copper supply lines from the outlet ports to the 2 desired devices making sure all piping and fittings are secured.
FINISHED WALL
CARTRIDGE
STEM
CARTRIDGE
STEM
4. Turn on the water supply and operate the
CARTRIDGE STEM to flush out the lines and check for leaks.
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM
[CLOSED]
5. After the supply lines have been fully flushed, turn off the water.
NOTE: Verify all VALVE positions are functioning properly.
TILE GUARD
6. Install the TILE GUARD to protect the DIVERTER
VALVE during the completion of the finished wall and to create the exact opening required to ensure access to the CARTRIDGE for future servicing.
PAGE 3 OF 3 | UPDATED ON 10.13.2021
advertisement