Clayton Warthog WTX-215T-0 Safety, Operation & Maintenance

Clayton Warthog WTX-215T-0 Safety, Operation & Maintenance
Add to My manuals

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Clayton Warthog WTX-215T-0 Safety, Operation & Maintenance | Manualzz

Safety – Operation – Maintenance

Keep this document in a safe place

Read and understand this manual before operating your vacuum

Warthog WTX

Industrial Vacuum 120V / 220V

Models with Prefix: WTX-115T-0, WTX-205T-0, WTX-215T-0

• Designed for toxic dust cleanup and housekeeping

• Dry Recovery Only

Scan this QR code for online instructions and documentation, or visit www.ClaytonHowTo.com

WARNING

SAFETY LEGEND

WARNING

Read and understand operator’s manual before using this equipment.

WARNING

Eye protection is required when operating this equipment.

WARNING

Hearing protection is recommended when operating this equipment.

WARNING

Respiratory protection is recommended when operating this equipment.

WARNING

• A HEPA Filter must be installed in this vacuum at all times

• If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required

• Any alteration to this equipment by a third party will nullify its warranty

October 2019

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE

When using an electrical appliance, basic precautions should always be followed, including the following:

WARNING

• To reduce the risk of fire, electric shock, or injury:

• Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.

• This unit is to be used only indoors and in a dry location.

• Use only as described in this manual. Use only manufacturer’s recommended attachments.

• Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.

• Handle provided on power head is used only for removal of power head during maintenance.

• Before separation of power head from tank, users must disengage draw latches on tank.

• Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners.

• Do not run appliance over cord. Keep cord away from heated surfaces.

• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.

• Do not handle plug or appliance with wet hands.

• Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.

• Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.

• Turn off all controls before unplugging.

• Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present.

• Connect to a properly grounded outlet only. See Grounding Instructions.

• Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.

• Do not use without all filters in place.

• Do not allow to be used as a toy. Close attention necessary when used by or near children.

SAVE THESE INSTRUCTIONS

EARTHING/GROUNDING INSTRUCTIONS

This appliance must be earthed/grounded. If it should malfunction or breakdown, earthing/grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-earthing/grounding conductor and earthing/grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and earthed/grounded in accordance with all local codes and ordinances.

WARNING – Improper connection of the equipment-earthing/grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly earthed/grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

See Power Head Name Plate for electrical requirements

USA 120V

This appliance has a earthing/grounding attachment plug that looks like the plug illustrated in Figure 1. Make sure that the appliance is connected to an outlet having the same configuration as the plug.

No adaptor should be used with this appliance.

International 120V

This appliance has a IEC 60309 125V earthing/grounding attachment plug.

Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance

International 220-240V

This appliance has a IEC 60309 250V earthing/grounding attachment plug.

Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance.

Earthed/Grounded

Outlet

Earthing/Grounding

Pin

Earthed/Grounded

Outlet Box

Figure 1: Earthed/Grounded Outlet and Plug

Repair or Warranty Contact

Page 2

Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

TABLE OF CONTENTS

Important Safety Instructions ..............................................................................................2

Save These Instructions .....................................................................................................2

Table of Contents ................................................................................................................3

Applications & Environments ..............................................................................................3

What’s Included ..................................................................................................................4

Specifications & Requirements ...........................................................................................4

Getting Started ...................................................................................................................4

Differential Pressure Gauge ...............................................................................................5

Before Each Use ................................................................................................................6

Bag Filter Change ...............................................................................................................6

Safe Filter Change ..............................................................................................................7

Pre-Filter Change ...............................................................................................................8

HEPA Filter Change ............................................................................................................9

Illustrated Parts Breakdown ..............................................................................................10

Limited Lifetime Warranty Terms and Conditions .............................................................13

Declaration of Conformity .................................................................................................14

APPLICATIONS & ENVIRONMENTS

• Designed for toxic dust cleanup and housekeeping

• Dry Recovery Only

WARNING

Do not use this equipment for cleaning or extracting fuel residues from any vehicle or equipment

Do not use this equipment for cleaning or extracting live sparks or burning embers

Do not use this equipment for use in combustible dust or gas atmospheres

Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

Page 3

WHAT’S INCLUDED

Clayton Warthog Power Heads ship with the following items:

• Warthog WTP Power Head

• HEPA 12 Month Timer Card

Clayton Vacuum Tanks ship separately and include

Bags, Filters, and other components. These instructions asume you have both a Power Head and one of the following Clayton Vacuum Tanks 603-205T 603-215T

SPECIFICATIONS & REQUIREMENTS

Weight ...........................................................................20 lbs (9 kg)

Dimensions ....................................................................17.5 x 17.5 x 12 in (44.5 x 44.5 x 30.5 cm)

HEPA Filter Efficiency ....................................................99.995% @ 0.3 μm (H14)

Filter Bag Efficiency .......................................................95% @ 0.5 micron

Sounds Pressure Level .................................................<70 dBA

Compressed Air Consumption .......................................Determined by Tool

Compressed Air Supply Pressure..................................90-120 PSI (6.2 - 8.3 bar)

120 Volt

Power Consumption ...... 120VAC~ 12.5A

Vacuum Flow ................. 120 CFM (204 SCMH)

Vacuum Suction ............. 120 in/H

2

O (30 kPa)

220-240 Volt

Power Consumption ...... 220-240VAC~ 5.5-6A

Vacuum Flow ................. 120 CFM (204 SCMH)

Vacuum Suction ............. 120 in/H

2

O (30 kPa)

GETTING STARTED

1. The vacuum Power Head and the Vacuum Tank ship in separate boxes

2. Unbox the Vacuum Power Head

3. Visually inspect Power Head to ensure that no parts are missing or damaged

4. Familiarize yourself with the Power Head

Differential

Pressure Gauge

Power Cord

Power Switch

603-115T

Repair or Warranty Contact

Page 4

HEPA Wire Lock

Hex Standoff Filter Adapter

HEPA Wire Lock

Hex Standoff

Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

GETTING STARTED

WARNING

5. Power Head Vents

• NEVER BLOCK THE POWER HEAD VENTS

• NEVER WRAP THE POWER CORD AROUND THE POWER HEAD VENTS

Vents

Preparing the Vacuum for Use

1. Install a Filter Bag

• Unfold and fluff a new Filter Bag

• Push the inlet tube into the hole on the cardboard collar of the Filter Bag

• Grasp the sides of the cardboard collar and push it all the way on to the inlet tube

• Ensure the bottom of the collar is past the opening on the underside of the inlet tube

2. Unbox a new HEPA Filter

• Remove the Clayton HEPA Timer Card from the box and set aside

• Remove the HEPA Cable Lock from the box and set aside

• Remove the HEPA Filter from the box and remove from plastic bag

3. Install a new HEPA Filter

• Holding the power head on its side, screw the new HEPA Filter onto the threaded nipple

• Ensure the white inner ring of the HEPA Filter is in contact with the underside of the power head

• If it is not, turn it clockwise until it comes in contact with the underside of the power head

• See the instructions included with the HEPA Cable Lock

4. Attach the Power Head

• Sit the Power Head on the tank

• Rotate the Power Head so that the switch on the Power Head is in line with the inlet port on the vacuum tank

• Latch the Power Head to the tank

DIFFERENTIAL PRESSURE GAUGE

Principle of Operation

As the Bag Filter, Prefilter, and HEPA filter are loaded with debris, the debris restricts airflow thru the filters. This restriction increases the differential pressure which is displayed on the Gauge located on the side of the power head. This can help determine when to change the bag filter, HEPA Filter, and/or Prefilter.

Clayton recommends that the bag filter be changed when it is approximately 75% full by volume. Keep in mind that If the debris is something like fine powder it will create more restriction and therefore a greater differential pressure than something like rivet stems.

The differential pressure gauge has a range of 0 to -100.

We recommend that each customer test the vacuum in situ to determine their gauge readings for both clean filters and a bag filter 75% full using the procedure below.

1. Testing the Differential Pressure

Each customer should tailor their differential pressure testing schedule based on how quickly the bag filter will typically reach capacity in their specific environment.

2. Activating the Vacuum

• Toggle the Power Switch to the ON Position

3. Reading the Gauge

• Hold the inlet port open with your hand (do not insert a hose)

• Read the gauge

• Close the inlet port

• Deactivate the vacuum

4. Changing the Filters

• If, based on the differential pressure gauge reading, you determine that the bag filter needs to be replaced, See the bag filter change section of this document

• If, after replacing the bag filter, the differential pressure gauge does not return to the clean filter reading, the prefilter and/or HEPA filter may need to be changed

• See the prefilter change and/or HEPA Filter change section of this document

Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

Page 5

BEFORE EACH USE

1. Attach the Vacuum Hose

Vacuum Hose only

• Open the Vacuum Inlet

• Insert the metal sleeve of the vacuum hose into the inlet on the vacuum

2. Activating the Vacuum

• Toggle the Power Switch to the ON Position.

BAG FILTER CHANGE

If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.

The bag filter should be replaced then ¾ full

1. Safe the Vacuum

• Disconnect the Vacuum from power source

2. Remove the Power Head

• Unlatch the Power Head from the tank

• Lift the Power Head and attached HEPA filter off the tank by the top handle

• Carefully sit the Power Head on the floor - avoid damaging the HEPA filter

3. Remove the Filter Bag

• Grasp the cardboard collar of the bag filter and slide it off the inlet

• Holding your hand over the opening on the bag, lift the bag out of the tank

• Dispose of the bag according to your company policy

4. Install a Filter Bag

• Unfold and fluff a new Filter Bag

• Push the inlet tube into the hole on the cardboard collar of the Filter Bag

• Grasp the sides of the cardboard collar and push it all the way on to the inlet tube

• Ensure the bottom of the collar is past the opening on the underside of the inlet tube

5. Ensure the HEPA Filter is sealed

• Holding the power head on its side, look at the HEPA Filter

• Ensure the white inner ring of the HEPA Filter is in contact with the underside of the power head

• If it is not, turn it clockwise until it comes in contact with the underside of the power head

6. Replace the Power Head

• Sit the Power Head on the tank

• Rotate the Power Head so that the switch on the Power Head is in line with the inlet port on the vacuum tank

• Latch the Power Head to the tank

Repair or Warranty Contact

Page 6

Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

SAFE FILTER CHANGE

Principle of Operation

Safe Filter Change uses a second Clayton HEPA Vacuum and Safe Filter Change Hose to create a downdraft in the Primary Vacuum while changing the bag filter.

If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.

The bag filter should be replaced when ¾ full

1. Connect the Vacuums

• Position the Support Vacuum with its inlet port facing the SFC Port on the Primary Vacuum

• Open the Inlet port on the Support Vacuum

• Insert the metal sleeve of the SFC hose into the inlet port on the vacuum

• Open the SFC Port on the Primary Vacuum

• Insert the metal sleeve of the SFC hose into the SFC Port on the Primary Vacuum

• Plug both vacuums into power

2. Remove the Power Head

• Unlatch the Primary Vacuum Power Head from the tank

• Lift the Primary Vacuum Power Head and attached HEPA filter off the tank approximately 1in, by the top handle

• Toggle the Support Vacuum Power Switch to the ON Position to create the downdraft

• Toggle the Primary Vacuum Power Switch to the ON Position to prevent any debris from falling off the HEPA Filter

• Lift the Primary Vacuum Power Head and attached HEPA filter off the tank by the top handle

• Carefully sit the Power Head on the floor - avoid damaging the HEPA filter, leave the Primary Power Head running

3. Remove the Bag Filter

• Turn a large disposal bag inside out around your arms

• Using the disposal bag like a large mitten, grasp the cardboard collar of the Bag Filter and slide it off the inlet

• The disposal bag should remain between the user and the Bag Filter

• Gently lift the Bag Filter, while drawing the disposal bag down and around the Bag Filter

• Gather the neck of the disposal bag, and seal the bag closed using tape or ties

• Dispose of the according to your company policy

4. Install a Bag Filter

• Unfold and fluff a new Bag Filter

• Push the inlet tube into the hole on the cardboard collar of the Bag Filter

• Grasp the sides of the cardboard collar and push it all the way on to the inlet tube

• Ensure the bottom of the collar is past the opening on the underside of the inlet tube

5. Ensure the HEPA Filter is sealed (Optional)

• Holding the power head on its side, look at the HEPA Filter

• Ensure the white inner ring of the HEPA Filter is in contact with the underside of the power head

• If it is not, turn it clockwise until it comes in contact with the underside of the power head

6. Replace the Power Head

• Sit the Primary Power Head on the tank

• Toggle the Primary Vacuum Power Switch to the OFF Position

• Rotate the Power Head so that the switch on the Power Head is in line with the inlet port on the vacuum tank

• Latch the Power Head to the tank

• Toggle the Support Vacuum Power Switch to the OFF Position

7. Disconnect the Vacuums

• Disconnect the SFC Hose from the Primary Vacuum SFC Port

• Disconnect the SFC Hose from the Support Vacuum Inlet Port

Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

Page 7

PRE-FILTER CHANGE

If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.

The pre-filter should be replaced if clogged or visibly dirty

1. Safe the Vacuum

• Disconnect the vacuum from power source

2. Remove the Power Head

• Unlatch the Power Head from the tank

• Lift the Power Head and attached HEPA filter off the tank by the top handle

• Carefully sit the Power Head on the floor - avoid damaging the HEPA filter

3. Remove the Pre-Filter

• The Pre-Filter is wrapped around the HEPA filter and secured with Velcro

• Find the seam and carefully peel the Velcro apart

• Dispose of the Pre-Filter according to your company policy

4. Install a new Pre-Filter

• Unfold a new Pre-Filter and remove the thin Velcro cover strip from the Velcro hooks

• Wrap the Pre-Filter tightly around the HEPA filter

• Secure the Pre-Filter by adhering the Velcro hooks to the side of the Pre-Filter

5. Replace the Power Head

• Sit the Power Head on the tank

• Rotate the Power Head so that the switch on the Power Head is in line with the inlet port on the vacuum tank

• Latch the Power Head to the tank

Repair or Warranty Contact

Page 8

Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

HEPA FILTER CHANGE

If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.

The HEPA filter should be replaced when it is damaged, clogged, or when the HEPA timer card has reached

12 months.

1. Safe the Vacuum

• Disconnect the Vacuum from power source

2. Remove the Power Head

• Unlatch the Power Head from the tank

• Lift the Power Head and attached HEPA filter off the tank by the top handle

• Carefully sit the Power Head on the floor - avoid damaging the HEPA filter

3. Unbox a new HEPA Filter

• Remove the Clayton HEPA Timer Card from the box and set aside

• Remove the HEPA Cable Lock from the box and set aside

• Remove the HEPA Filter from the box and remove from plastic bag

4. Remove the HEPA Filter

• Holding the Power Head on its side cut the HEPA Cable Lock and remove

• Unscrew the HEPA Filter

• Dispose of the HEPA Filter according to your company policy

5. Install a new HEPA Filter

• Holding the power head on its side, screw the new HEPA Filter onto the threaded nipple

• Ensure the white inner ring of the HEPA Filter is in contact with the underside of the power head

• If it is not, turn it clockwise until it comes in contact with the underside of the power head

• See the instructions included with the HEPA Cable Lock

6. Replace the Power Head

• Sit the Power Head on the tank

• Rotate the Power Head so that the switch on the Power Head is in line with the inlet port on the vacuum tank

• Latch the Power Head to the tank

7. Activate the HEPA Filter Timer

• Remove the old HEPA timer card from the power head

• Attach the new HEPA timer card with a zip tie (included) to the top handle of the vacuum

• Follow the directions on Timer Card to activate

Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

Page 9

ILLUSTRATED PARTS BREAKDOWN

603-WTX-0

SEQ ITEM NO

1 600-A108-120

9

10

11

12

13

4

5

6

2

3

7

8

17

18

19

14

15

16

601-021

601-121

605-310B16

900-WH003

911-011

911-Q6600-220T

925-V40R100-02

927-04L

927-04L-04F

930-015

FE103208-HZSM-B

NE10320608-HNSZ

NE10320615-HNSZ

NE16201420-HNSZ

SE162005-PPSM-Z

SE162064-HHSM-Z

922-T.25GN

600-WF-1364F

DESCRIPTION

MOTOR ASSEMBLY 120V

FILTER ADAPTER, WARTHOG

MESH DISC, 3 IN DIAMETER

HH VAC HEAD BASE 16IN SS BLACK

WIRING HARNESS, WGX GENERAL

GASKET, FILTER ADAPTER

CONICAL MOTOR GASKET SILICA GEL

GAUGE VACUUM 2.5IN 0-100 IN/H2O PANEL MOUNT

1/4 PC ELBOW

FTG, 1/4 X 1/4 ELBOW, PC TO FNPT

TUBING .250OD X .125ID PTFE

HEX STANDOFF, 10-32 MF X 1/2 SS WITH BORE

NUT 10-32 NYLON LOCK SS SHORT

NUT, 10-32 NYLON LOCK, SS, HIGH

NUT 1/4-20 HEX LOCK SS

SCREW, 1/4-20 X 5/16 PH, SS

SCREW 1/4-20 X 4IN SS HEX

1/4 IN OD. NYLON TUBING GREEN

WASHER FIBER 13/64 ID X 3/8OD

15

1

5

13

WIRING HARNESS REPRESENTATIVE

ACTUAL HARNESS MAY DIFFER IN APPEARANCE

7

4

16

3

8

10

11

9

18

Repair or Warranty Contact

Page 10

17

6

12

2

14

19

Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

ILLUSTRATED PARTS BREAKDOWN

603-WTX-0

SEQ ITEM NO

1 911-803-1

4

5

6

2

3

6

6

911-803-2

911-803-3

911-803-5

911-803-4

911-803-6

911-803-7

911-803-8

DESCRIPTION

HANDLE CAP SOUND CONTROL FOAM

EXHAUST BAFFLE SOUND CONTROL FOAM

ENCLOSRE TOP SOUND CONTROL FOAM

MOTOR PLATE SOUND CONTROL FOAM

BASE RING SOUND CONTROL FOAM

ENCLOSURE FOAM 1 SOUND CONTROL

ENCLOSURE FOAM 2 SOUND CONTROL

ENCLOSURE FOAM 3 SOUND CONTROL

1

5

4

2

3

6

Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

Page 11

ILLUSTRATED PARTS BREAKDOWN

603-WTX-0

SEQ ITEM NO

1 350-023

12

13

14

15

9

10

11

4

5

6

2

3

7

8

605-310A

605-310D

605-314E

900-143N515P-30

900-M14R3

900-M14S

900-SW-SPDT-01

930-027

FE103212-HZSM-Z

NE10320608-HNSZ

RE0620-SDSSS-Z

SE103206-XPSM-Z

WE133203-RFS-Z

WE481831-RZSZ

DESCRIPTION

STRAIN RELIEF FOR 20 AMP CORD

HH VAC HEAD HANDLE CAP SS BLACK

HH VAC HEAD EXHAUST BAFFLE SS BLACK

WTX ENCLOSURE TOXIC DUST ELECTRIC SS BLACK

CORD 14/3 15A CORD LOCK PLUG 30FT YEL

MOLEX RECETACLE, 14 GA, 3 POSITION

MOLEX SOCKET TERMINAL, 14 GA

SWITCH ROCKER RECT 20A 120V SPDT ON-OFF-ON BLACK

HANDLE, CARRY, FLEX RUBBER

HEX STANDOFF, 10-32 MF X 3/4 IN SS

NUT 10-32 NYLON LOCK SS SHORT

RIVET BLIND 3/16 X 0.625 SEALED SS (.251-.375)

SCREW 10-32 X 3/8IN SS TORX

WASHER .203ID X .500OD .047H ROUND STAINLESS STEEL

SHIM .750 ID X 1.125 OD X .048 ROUND STAINLESS

12

14

9

13

2

10

Repair or Warranty Contact

Page 12

3

10

REF

5

15

1

6 7

4

8

11

Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

LIMITED LIFETIME WARRANTY TERMS AND CONDITIONS

Warranty Terms

Clayton Associates, Inc. guarantees its manufactured products against defects in materials or workmanship and will either repair or replace all parts that prove defective under normal use during the lifetime of the products. The warranty period shall commence from the date of paid invoice.

This warranty does not cover (a) repairs due to normal wear, accident, neglect, misuse, or use other than as indicated in the instruction booklet (b) products manufactured by third parties and distributed by Clayton (c) wear items such as bearings, rotor blades, regulators, valve stems, levers, shrouds, guards, O-rings, seals, gaskets, motor brushes, and other wearable parts.

Repair within the Continental US

During the first 90 days of the warranty period, Clayton will provide parts and labor to the customer’s site at no charge or pay freight costs associated with returning the products for repair to a Clayton selected service location and repair the product at no charge.

Clayton personnel will determine the best way to repair the product.

Past 90 days, Clayton will provide parts to the customer’s site at no charge or the customer may ship the product to a Clayton selected service location at customer’s expense and Clayton will repair the product at no charge and provide return shipping.

Repair Outside the Continental US

Clayton will provide parts to the customer’s site at no charge or the customer may ship the product to a Clayton selected service location at customer’s expense and Clayton will repair the product at no charge and provide return shipping.

Limitation of Liability

Clayton shall not in any event be liable for any damages, loss of production time or profits, whether based on contract, warranty, negligence, strict liability or otherwise, including without limitation any consequential, incidental or special damages, arising with respect to the equipment or its failure to operate.

Clayton Associates, Inc. makes no other warranty or representation of any kind, except that of title, and all other warranties, express or implied, including warranties of merchantability or fitness for any particular purpose, are hereby expressly disclaimed.

Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

Page 13

EC DECLARATION OF CONFORMITY

Clayton Associates, Inc. of 1650 Oak Street, Lakewood New Jersey 08701 U.S.A. declare on our own responsibility that the following equipment:

Industrial HEPA Filtered, Electrically Powered Vacuum Cleaners and Accessories for Dry Recovery

• Vacuum Models (where XXXX is the Tank Model):

WGX-XXXX-0, WGP-XXXX-0, WTX-XXXX-0, WTP-XXXX-0

WGX-XXXX-1, WGP-XXXX-1, WTX-XXXX-1, WTP-XXXX-1

• Tank Models: 115G,115T,205G, 205T, 215G, 215T

• With serial numbers ranging from WH0000001 through WH9999999

Are designed and manufactured in compliance with the essential requirements and other relevant provisions of the following applicable directives:

• Machinery Directive 2006/42/EC

• The Electromagnetic Compatibility Directive 2004/108/EC

Compliance has been obtained by application of the following standards:

• EN ISO 12100:2010-11

• EN 60335-1:2012/A13 excluding 25.6

• EN 60335-2-69:2012 specifically Annex AA: Requirements for vacuum cleaners and dust extractors for the collection of hazardous dusts

• EN 55014-1:2017

• EN 55014-2:2015

The legally authorized entity, established in the EU for compiling the technical file is ExVeritas Limited, Unit 16-18, Abenbury

Way, Wrexham Industrial Estate, Wrexham, LL13 9UZ, United Kingdom.

File Number: 18FILE0423

Subject to use for the purpose for which it was designed in accordance with relevant standards and with the manufacturer’s recommendations. We hereby declare that the equipment specified above conforms to the listed Directives and Standards.

Brad Clayton

President

Clayton Associates, Inc.

Place of Issue: Lakewood, New Jersey, USA November 23, 2018

Repair or Warranty Contact

Page 14

Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

EC DECLARATION OF CONFORMITY

Clayton Associates, Inc. of 1650 Oak Street, Lakewood New Jersey 08701 U.S.A. declare on our own responsibility that the following equipment:

Industrial HEPA Filtered, Electrically Powered Vacuum Cleaners

• Vacuum Models (where XXXX is the Tank Model):

WGX-XXXX-0, WGP-XXXX-0, WTX-XXXX-0, WTP-XXXX-0

WGX-XXXX-1, WGP-XXXX-1, WTX-XXXX-1, WTP-XXXX-1

• Tank Models: 115G,115T,205G, 205T, 215G, 215T

• With serial numbers ranging from WH0000001 through WH9999999

Were tested to verify the integrity of the HEPA filter and the assembled machine

Test Procedure:

• The test was performed using an aerosol generator and a photometer.

• The system was challenged with 18 microliters/mᶟ Poly Alfa Olefin (PAO).

• The system was fitted with a HEPA filter, part number 627-12H having a certified minimum efficiency of 99.995%.

Test Results:

• The filtration efficiency of the assembled Warthog vacuum was 99.9978%

• Test performed at: 740 Driving Park Avenue, Rochester NY 14613 USA

Declaration:

• The assembled unit meets the standard for US HEPA filtration and EU H14.

Brad Clayton

President

Clayton Associates, Inc.

Place of Issue: Lakewood, New Jersey, USA October 18, 2018

Repair or Warranty Contact

Page 15

Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

Clayton products are proudly made in the USA

Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • [email protected]

advertisement

Related manuals