Eterna SDCSLEDCR is a versatile LED ceiling/wall fitting with a built-in microwave sensor that automatically switches on the light when it detects movement, making it ideal for areas like corridors, bathrooms, or entrances. It offers adjustable detection range, hold time, and color temperature, allowing you to customize it to your specific needs. Additionally, the 10% step-dim (corridor) function ensures energy efficiency by reducing the light output to 10% after a selected time delay after motion detection.
Advertisement
Advertisement
MICROWAVE SENSOR SPECIFICATIONS:
PRODUCT
TYPE
Operating Voltage
HF System
Transmission Power
Detection Angle
Power Consumption
Detection Range
Time Setting
Mounting
Working Temp
10% STEP DIM
MICROWAVE MOTION
SENSOR
220-240VAC 50/60Hz
5.8GHz CW radar
<0.2mW
30-150 Degree
<0.5W
Max. 12-18m adjustable
5s-30m
Indoors: ceiling and wall
-20 to +60 degree
RED DIRECTIVE
Eterna Lighting Ltd
Microwave Occupancy Sensor
Full declaration available at www.eterna-lighting.co.uk
LAMP REPLACEMENT:
The light source is designed to last the lifetime of the luminaire.
The light source contained in this luminaire shall only be replaced by the manufacturer, service agent or a similar qualified person.
CAUTION, RISK OF ELECTRIC SHOCK.
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” effective August 2005—UK WEEE
Regulations effective 2nd January 2007). Environment
Agency Registered Producer: WEE/GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST - DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Clean this fitting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.
See website for more information on replacability and recycling
LED LAMP SPECIFICATIONS:
1250 lm
Luminaire lumens (with diffuser):
Warm White, Cool White, Daylight White
Lumens from chip (array): Warm
White, Cool White, Daylight
White
1350 lm
1300 lm
1700 lm
1850 lm
Useful lumens (array): Warm
White, Cool White, Daylight
White
Rated Wattage
1750 lm
1200 lm
1300 lm
1250 lm
17W
Rated luminous flux
Nominal life time of the lamp
1200/1300/1250 lm
35,000 hrs
Colour temperature
Number of switching cycles before premature lamp failure
Warm-up time up to 60% of the full light output
Dimmable
Nominal beam angle
Rated power
Rated lamp lifetime
3100/4200/6400K
15,000
Instant full light
No
120°
17W
35,000 hrs
0.89
Displacement factor
Lumen maintenance factor at end of nominal life
Starting time
Colour rendering
Colour consistency
>0.7
<0.1s
>80 Ra
Within 6 step
Macadam ellipse
Rated peak intensity
Rated beam angle
520cd
120°
Voltage / Frequency 240V~50Hz
Not suitable for accent lighting
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return it to the place where you bought it. Our
Technical Team will gladly advise on any Eterna
Lighting product, but may not be able to give specific instructions regarding individual installations.
Issue 0821
Email: [email protected] / [email protected]
Visit our website: www.eterna-lighting.co.uk
Made in China
INSTALLATION INSTRUCTIONS
A guide for qualified electricians
Polished Chrome
Pack contents:
1 x LED ceiling fitting
Detection
Area
Hold Time
Antenna
Module
LED
Indication
10%
Step Dim
Microwave
Sensor
White
Off / On
OFF ON
Model:
SDCSLEDCR / SDCSLEDWH
LED Colour Temperature Selectable Ceiling/Wall Fitting With
10% Step-dim (Corridor Mode) Microwave Sensor
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
This product must be installed by a competent person in accordance with the current building and
IEE wiring regulations.
As the buyer, installer and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. Eterna Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal domestic service. Using this fitting in any other environments may result in a shortened working life, for example where there is prolonged periods of use or higher than normal ambient temperatures such as lighting public or shared spaces or in nursing /care home facilities.
Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off
MCB.
This product is suitable for use in living areas,
Bathroom Zone 2 and outsides of zones.
If being fitted in a bathroom a 30mA RCD must be used.
Bathroom Zones Diagram
ZONE 2 ZONE 1
ZONE 2
225cm
240cm
60cm radius from tap
60cm
ZONE 0
This product is designed for permanent connection to fixed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
This product is suitable for installation on surfaces with normal flammability e.g. wood, plasterboard and masonry. It is not suitable for use on highly flammable surfaces (e.g. polystyrene, textiles).
Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
The chosen location of your new fitting should allow for the product to be securely mounted (e.g. to a ceiling joist) and safely connected to the mains supply (lighting circuit).
When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.
This product must be connected to earth termination.
This product is not intended to be used by children and persons with sensory, physical and/or mental impairments that would prevent them from using it safely.
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specified in the current IEE wiring and building regulations.
INTRODUCTION:
The ceiling / wall light incorporates a microwave sensing device which continuously scans the operating zone and immediately switches the light on when it detects movement in that area.
This means that whenever movement is detected within the range of the sensor the light will switch on automatically and illuminate the area you have selected to light. While there is movement within range of the unit the light will remain on.
A microwave sensor is an active motion detector emitting high-frequency electro-magnetic waves at
5.8GHz and receiving their echo. The sensor detects change in the echo pattern within its detection zone and the light is then triggered. The wave can pass through doors, glass and thin walls and will continually monitor the signal within the detection area.
INSTALLATION:
Choose the location for your new fitting according to the conditions listed opposite.
01) Hold the base of the fitting and gently turn the diffuser and decorative trim anti-clockwise and lift off.
02) Unscrew and remove LED gear tray.
03) Drill holes in the back of your fitting for your fixing screws, take care and drill gently to ensure a clean hole through. Use a drill bit sized appropriately to your fixing screws (not supplied).
04) Using the back of your fitting as a template, mark the position of your fixing holes on your mounting surface.
05) Prepare the holes in your mounting surface as appropriate for your fixings.
06) Pierce the rubber grommet in the back of your fitting making a hole just large enough to make a tight fit around the incoming mains cable.
07) Thread the cable through the grommet and offer the fitting to the ceiling / wall.
08) Secure the fitting in place. Note, if protection against ingress of moisture is required, the heads of screws must be covered with a silicone or similar sealant.
09) Check that the grommet is still correctly fitted in the cable entry hole and around the incoming cable.
10) Make the electrical connections to the terminal block according to the markings:
Brown to live (L) • Blue to neutral (N)
Earth green & yellow ( )
1
11) Connect the plug/socket between terminal block and gear tray.
12) Replace gear tray and secure in position with the three screws.
13) Set colour temperature to the desired option. See below.
14) Set desired settings on microwave.
15) Offer the diffuser and decorative trim onto the top of the fitting and turn clockwise until they are held securely.
16) Restore the power and check fitting is working correctly. A green light should always be present indicating the fitting is charging.
NOTE: In warm white
(3100K) and daylight white
(6400K) operation only one set of LEDs will illuminate, in cool white (4200K) both sets of LEDs will illuminate.
2
Blue
(Power Cable)
Yellow/Green
(Power Cable)
Brown
(Power Cable)
WW
K Temp
3100K
DL 6400K
LEDs On
All Orange
All Yellow
CW 4200K
All Orange
All Yellow
= ON = OFF
ON
OFF
NEUTRAL
(Power Cable)
EARTH
(Power Cable)
LIVE
(Power Cable)
UNDERSTANDING THE CONTROLS:
Refer to microwave sensor diagram on front page.
This luminaire has a step dim (corridor) function - operation is at 100% light level after last presence detection, reducing to 10% light output after installer selected time delay.
The sensor is an active motion detector: it emits a high frequency electromagnetic wave 5.8GHz and receives its echo. The sensor detects the change in echo from movement in its detection zone. A microprocessor then triggers the switch light ON command. Detection is possible through doors, panels of glass and thin walls.
NOTE: The microwave settings control when
100% output is achieved; it is not possible to disable the 10% setting.
DETECTION RANGE:
This determines the effective range of the motion detector and is set up by DIP switches at the sensor itself, refer to figure. Note that reducing the sensitivity will also narrow the detection range.
The following settings are available:
I - Detection Range 100%
II - Detection Range 75%
III - Detection Range 50%
IV - Detection Range 25%
V - Detection Range 10%
HOLD TIME:
I
II
DETECTION AREA
1
2
3
100%
75%
III 50%
IV 25%
V 10%
KEY: ON: OFF:
This determines the time the fitting remains at
100% level on motion detection and is set with DIP switches at the sensor itself, refer to figure. The walk test setting is useful when installing the fitting to establish correct operation and range.
The following settings are available:
I - 5s
II - 30s
III - 1 minute
IV - 5 minutes
V - 15 minutes
VI - 30 minutes
I
II
1
HOLD TIME
2
3
4
5s
30s
III 1min
IV 5min
V 15min
VI 30min
KEY: ON: OFF:
ON
OFF
ON
OFF
DAYLIGHT SENSOR:
The Daylight Sensor options cannot be adjusted with this model. It is supplied preset to disabled and should not be amended.
The photocell is mounted inside the enclosure and lower daylight levels may not be detected through the diffuser. Select dip switch setting VI to disable the Photocell. On presence detection the fitting will run at 100% and then return to 10% corridor function after the pre-set Hold Time in daytime and night time operation.
Eterna Lighting Ltd
SDCSLEDCR
Eterna Lighting Ltd
SDCSLEDWH
17 17
Advertisement