Aruba 3200 Mobility Controllers (AOS) Installation Guide
โฆษณา
โฆษณา
Mobility Conductor
Hardware Appliance
Copyright
© Copyright 2020 Hewlett Packard Enterprise Development LP
Open Source Code
This product includes code licensed under the GNU General Public License, the GNU Lesser General Public License, and/ or certain other open source licenses.
A complete machine-readable copy of the source code corresponding to such code is available upon request. This offer is valid to anyone in receipt of this information and shall expire three years following the date of the final distribution of this product version by Hewlett Packard Enterprise Company.
To obtain such source code, send a check or money order in the amount of US $10.00 to:
Hewlett Packard Enterprise Company
Attn: General Counsel
6280 America Center Drive
San Jose, CA 95002
USA
www.arubanetworks.com
Hewlett Packard Enterprise Company
Attn: General Counsel
6280 America Center Drive
San Jose, CA 95002
Mobility Conductor Hardware Appliance | Installation Guide Revision 04 | April 2021
Contents
Contacting Support .................................................................................................. 5
Mobility Conductor Hardware Appliance ......................................... 7
Mobility Conductor Hardware Appliance Components....................................... 8
Required Tools and Equipment .....................................................................14
Required Tools and Equipment .....................................................................16
Required Tools and Equipment .....................................................................17
Connecting and Disconnecting the AC Power Cord ...........................................18
Installing and Removing a Power Supply ...........................................................19
Installing a Power Supply Module .................................................................19
Removing a Power Supply Module................................................................19
Connecting and Removing an SFP/SFP+/LC Cable .............................................20
Specifications, Safety, and Compliance .......................................... 23
Mobility Conductor Hardware Appliance Specifications ...................................23
Aruba Mobility Conductor Hardware Appliance
| Installation Guide |
3
Waste of Electrical and Electronic Equipment..............................................26
4
|
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
Preface
This document describes the hardware features of the Aruba Mobility Conductor hardware appliance. It provides a detailed overview of the physical and performance characteristics of each appliance model and explains how to install the appliance and its accessories.
Guide Overview
Chapter 1, “Mobility Conductor Hardware Appliance” on page 7 provides a detailed hardware
overview of the Mobility Conductor hardware appliance and each of its components.
Chapter 2, “Installation” on page 13 describes how to install the Mobility Conductor hardware
appliance in a number of ways and how to install each its components.
Chapter 3, “Specifications, Safety, and Compliance” on page 23
lists the Mobility Conductor hardware appliance’s technical specifications and safety and regulatory compliance information.
Related Documentation
The latest ArubaOS 8.1.x User Guide and ArubaOS 8.1.x CLI Reference Guide are required for the complete management of an Aruba Mobility Conductor hardware appliance. The latest documentation and the translation of this document into other languages can be found at www.arubanetworks.com/documentation .
Contacting Support
Table 1
Contact Information
Main Site
Support Site arubanetworks.com
support.arubanetworks.com
Airheads Social Forums and Knowledge
Base community.arubanetworks.com
North American Telephone 1-800-943-4526 (Toll Free)
1-408-754-1200
International Telephones
Software Licensing Site arubanetworks.com/support-services/contact-support/ hpe.com/networking/support
End of Support information arubanetworks.com/support-services/end-of-life-products/end-oflife-policy/
Security Incident Response Team (SIRT) Site: arubanetworks.com/support-services/security-bulletins/
Email: [email protected]
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Preface |
5
6
| Preface
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
Chapter 1
Mobility Conductor Hardware Appliance
The Aruba Mobility Conductor hardware appliance manages, controls and intelligently integrates wireless Access Points (APs), Managed Devices and Air Monitors (AMs).
The Mobility Conductor hardware appliance includes the following models:
Table 2 Mobility Conductor Hardware Appliance Models
Model Number of Devices Number of Clients
MCR-HW-1K
MCR-HW-5K
MCR-HW-10K
1000
5000
10000
10000
50000
100000
The Mobility Conductor hardware appliance has the following port configuration:
Table 3
Mobility Conductor Hardware Appliance Port Configuration
Model Ports
MCR-HW-xK
2 x 10GBase-X (SFP+) ports
USB 3.0
Console Port
Management Port
The Mobility Conductor hardware appliance requires ArubaOS 8.1.0.0 or later version.
Package Checklist
Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the carton, including the original packing materials (see Table 4 ). Use these materials to repack and return the unit to the supplier if needed.
Table 4
Package Contents
Item Quantity
Aruba MCR-HW-xK Appliance
Mounting Brackets
M6 x 15 mm Phillips Pan Head Screws
M4 x 8 mm Phillips Flat Head Screws
M6 x 7 mm Grounding Screws
Power Cable
8
2
2
1
2
4
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Mobility Conductor Hardware Appliance |
7
Table 4
Package Contents (Continued)
Item
USB to RJ-45 Console Cable
PSU Filler Panel
Rubber Feet
Aruba Mobility Conductor Hardware Appliance Start-up Guide (Printed)
End User License Agreement (Printed)
Quantity
1
1
4
1
1
Optional accessories are available for use with the Aruba Mobility Conductor hardware appliance and are sold separately. Contact your Aruba sales representative for details and assistance.
Mobility Conductor Hardware Appliance Components
This section introduces the component and its location in the Mobility Conductor hardware appliance.
shows the front panel of the Mobility Conductor hardware appliance and Figure 2 shows the back panel of the Mobility Conductor hardware appliance.
Figure 1 Front Panel of the Mobility Conductor Hardware Appliance
Figure 2 Back Panel of the Mobility Conductor Hardware Appliance
LEDs
The front panel includes power, status, and peered LEDs that provide basic monitoring of the overall status of the Mobility Conductor hardware appliance.
8
| Mobility Conductor Hardware Appliance
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
The following table show the LED indicators and the corresponding status:
Table 5
LEDs
LED Function Indicator Status
Power
Status
Peered
System powers
System status
Reserved for future use
Green (Solid)
Off
Green (Solid)
Amber (Solid)
Off
N/A
Power On
Power Off
Operational
Major/Critical alarm
No power
N/A
10GBase-X (SFP+) Ports
The Mobility Conductor hardware appliance is equipped with two 10GBase-X (SFP+) data ports (0 and
1). These ports are intended for use with SFP/SFP+.
SFP/SFP+ modules are 10Gb hot-swappable, optical transceivers, which convert serial electrical signals to external serial optical or electrical signals. The ports support dual speed (1GbE or 10GbE) operation.
Each 10GBASE-X port is equipped with two LEDs that allow basic monitoring of status, activity, and configuration of the port. The behavior of the STATUS LED can be changed using the CLI.
LINK — Placed on the top left of the port, this LED displays the link status and activity of the port.
SPEED — Placed on the top right of the port, this LED displays the link speed at the port.
The LED behavior corresponding to each mode is listed in the following table
.
Table 6
10G Base-X Port LEDs
LED State Indicator Status
LINK
SPEED
On
Active
Off
10 Gbps
1 Gbps
Green (Solid)
Green (Blinking)
NA
Green (Solid)
Off
Link established, but no traffic
Port is transmitting or receiving data
No link
Link at 10 Gbps
Link at 1 Gbps
Aruba tests and supports Aruba approved optics within their appliance devices. Non-approved third party optics are not tested or supported; therefore, Aruba does not guarantee proper functionality of non-approved third party optics when used in an Aruba system. For a complete list of Aruba approved optics, contact your Aruba sales representative.
USB Interface
Currently, this port is not supported and is reserved for future use.
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Mobility Conductor Hardware Appliance |
9
Console Port
Use the serial CONSOLE port to allow direct local management. This port is a RJ-45 female connector
that accepts an RS-232 serial cable with a male connector. See Figure 3
.
Figure 3 Serial Console Port Pin-Out
Serial
Console Port
RJ-45 Female
Pin-Out
1
2
3
4
5
6
7
8
Direction
Input
Output
TxD
GND
GND
RxD
The communication settings for the Console port is shown in the following table:
Table 7
Console Terminal Settings
Baud Rate Data Bits Parity Stop Bits Flow Control
9600 8 None 1 None
The CONSOLE port is compatible only with RS-232 devices. Non-RS-232 devices, such as APs, are not supported.
Do not connect the Console port to an Ethernet switch or a PoE power source. This may damage the appliance.
USB to Serial Interface Cable
A USB to serial interface cable can be used to connect the serial console port of the Mobility
Conductor hardware appliance to a USB port of laptop or PC. See Figure 4 .
Figure 4 USB to Serial Interface Cable
RJ-45 Female
Pin-Out
5
6
7
8
1
2
3
4
TxD
GND
RxD
Internal
Connections
RJ-45
3
4
5
6
TxD
GND
RxD
DB-9
2
9
8
7
6
DB-9 Male
Pin-Out
5
4
3
2
1
Ground
RxD
TxD
Management Port
The Mobility Conductor hardware appliance is equipped with a 10/100/1000BASE-T Gigabit
Management (RJ-45) port.
The management port provides 10/100/1000 Mbps Ethernet access to the Mobility Conductor hardware appliance CLI, SNMP, and Web interface for complete system management and troubleshooting. It can also be used to connect to a separate management network.
10
| Mobility Conductor Hardware Appliance
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
The management port has an LINK LED on its left side and SPEED LED on its right side. During operation, these LEDs provide status information as shown in the following table:
Table 8
10/100/1000BASE-T (RJ-45) Management Port
LED Function Indicator Status
LINK
SPEED
Link Status Information
Interface Speed
Green (Solid)
Green (Blinking)
Off
Green (Solid)
Off
Link established, but no traffic
Port is transmitting or receiving data
No link
Link at 1000 Mbps
Link at 10/100 Mbps
Fan Module
The Mobility Conductor hardware appliance is equipped with three field-replaceable, hot-swappable fan modules. Each fan module features a fan that pull air through the chassis from the front through to the rear. The LED behavior on the fan module is as follows:
Green - Fan module is operational
Red - Fan module is faulty
The Mobility Conductor hardware appliance is not compatible with fan module from other Aruba hardware platforms.
Hot Swapping
Hot swapping allows you to replace a failed fan tray, making it unnecessary to shut down the Mobility
Conductor hardware appliance during the replacement procedure.
PSU 0 and 1
The Mobility Conductor hardware appliance is equipped with two 400W power supply, which is an autosensing, load-sharing, redundant power supply module that supports an input voltage of 100
VAC to 240 VAC. Each power supply has a country-specific power cord for connection to an AC power outlet. The appliance can operate with one or two active power supplies, depending on the demands of your configuration. The following sections describe features of the 400W AC power supply:
Load Sharing
Load sharing occurs when more than one power supply of the same rating is installed in the Mobility
Conductor hardware appliance and turned on. Load sharing divides the total power load of the appliance among all available power supplies. Since the power supplies work together, the effective power capacity of the appliance is increased with each additional power supply.
Redundancy
With power redundancy, the Mobility Conductor hardware appliance can continue normal operation even when a power supply fails or is turned off. When multiple power supplies are installed, if one becomes unavailable (fails, or is turned off or removed) the remaining power supplies will attempt to provide full power for the device. If the device’s total power load does not exceed the combined rated output of the remaining, operational power supplies, the appliance will continue to operate.
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Mobility Conductor Hardware Appliance |
11
Hot Swapping
Hot swapping allows you to replace one failed power supply while the other provides full power. This makes it unnecessary to shut down the Mobility Conductor hardware appliance during the replacement procedure.
Hot swapping is supported only when power redundancy is in effect. This requires that after the target power supply is removed, the device’s total power load does not exceed the combined rated output of the remaining power supplies.
LED Indicators
The following table shows the LED indicators and the corresponding status:
Table 9
Power Supply Module LED
Indicator Status
Green (Solid)
Green (blinking) at 1 Hz
Green (blinking) at 0.5 Hz
Amber (Solid)
Amber (blinking) at 1 Hz
Off
Power supply is operational.
Power supply is in standby.
Power cord is unplugged.
Fan module faulty or in protection.
Indicates warning. Power supply module can operate normally but high temperature without protection, fan speed slow down, voltage lower, high power, high current.
No power.
Grounding Point
To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, the appliance must be adequately grounded before power is connected. Connect a grounding cable to earth ground and then attach it to the chassis grounding point using two screws.
Comply with electrical grounding standards during all phases of installation and operation of the product. Do not allow the appliance’s chassis, network ports, power supply, or mounting brackets to contact any device, cable, object, or person attached to a different electrical ground. Also, never connect the device to external storm grounding sources.
12
| Mobility Conductor Hardware Appliance
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
Chapter 2
Installation
Installation of the device should be performed by a trained installation professional.
This chapter describes how to install an Aruba Mobility Conductor Hardware Appliance using the many mounting options available. The Mobility Conductor hardware appliance ships with an accessory kit that includes the equipment needed to install the appliance in standard, 19-inch telco rack.
“Selecting a Location” on page 14
“Rack Mounting- Standard” on page 14
“Rack Mount Installation- Mid” on page 16
“Table or Shelf Installation” on page 17
“Connecting and Disconnecting the AC Power Cord” on page 18
“Installing and Removing a Fan Module” on page 18
“Installing and Removing a Power Supply” on page 19
“Connecting and Removing an SFP/SFP+/LC Cable” on page 20
Please only use the included or Aruba specified cables, power cords, AC power supplies, and batteries. The power cord should not be used with other electric equipment than what is specified by Aruba.
接続ケーブル、電源コード、
AC
アダプタ、バッテリーなどの部品は、必ず添付品または指定品をご使用ください。
また、電源ケーブルは弊社が指定する製品以外の電気機器には使用できないためご注意ください。
Precautions
Ensure that the rack is correctly and securely installed to prevent it from falling or becoming unstable.
Dangerous voltage above 240VAC is always present while the Aruba Power Supply Module is plugged into an electrical outlet. Remove all rings, jewelry, and other potentially conductive material before working with this device.
Never insert foreign objects into the chassis, power supply, or any other component, even when the power supply is turned Off, unplugged, or removed.
Ensure that the main power is fully disconnected from the appliance by unplugging all power cords from their outlets. For safety, verify that the power outlets and plugs are easily reachable by the operator.
Do not handle electrical cables which are not insulated. This also includes network cables.
Keep water and other fluids away from the appliance to minimize electrical hazards.
Comply with electrical grounding standards during all phases of installation and operation of the product. Do not allow the appliance’s chassis, network ports, power supply, or mounting brackets
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Installation |
13
14
| Installation
to contact any device, cable, object, or person attached to a different electrical ground. Also, never connect the device to external storm grounding sources.
Perform installation or removal of the chassis or any module in a static-free environment. Proper use of anti-static body straps and mats is strongly recommended.
Modules must be kept in anti-static packaging when not installed in the chassis.
Do not ship or store this product near strong electromagnetic, electrostatic, magnetic, or radioactive fields.
Do not disassemble the chassis.
Selecting a Location
The Mobility Conductor hardware appliance, like other network and computing devices, requires the following “electronic-friendly” environment:
Reliable power
Verify that your electrical outlet is compatible with the Mobility Conductor hardware appliance power supply.
Cool, non-condensing ventilation
For proper operation, the Mobility Conductor hardware appliance requires an environment with an ambient air temperature between 0º C and 40º C (32º F and 104º F). Humidity must be kept at non-condensing levels, between 10% and 90%.
Where a large number of electrical devices are working in the same area, additional air conditioning or air circulation equipment may be required.
Ample space
For proper air circulation, leave at least 10 cm (4 inches) clearance all around the chassis.
Leave additional space in front and rear side of the chassis to access power cords, network cables, and indicator LEDs.
Limited electromagnetic interference
For best operation, keep the Mobility Conductor hardware appliance and all cords and cables at least 0.7 meters (2 feet) from fluorescent lighting fixtures, and 2 meters (6 feet) from photocopiers, radio transmitters, electric generators, and other sources of strong electromagnetic interference.
Rack Mounting- Standard
This mounting option allows mounting the Mobility Conductor hardware appliance in a two-post 19inch Telco rack.
Each Mobility Conductor hardware appliance should have its own mounting equipment. Do not place other networking equipment directly on top of a mounted Mobility Conductor hardware appliance. Failure to do so can damage the device.
Required Tools and Equipment
The following tools and equipment are required for installing a Mobility Conductor hardware appliance:
Mounting Bracket (x2) (included in the kit): Do not use for table or shelf installation
Screws for mounting bracket (x8): M4 x 8 mm Phillips Flat Head Screws (included in the kit)
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
Screws for system rack mount (x4): M6 x 15 mm Phillips Pan Head Screws (included in the kit)
Suitable Screwdrivers for all screw types provided in the box (not included in the kit)
Some racks require screws that differ from those included with the Mobility Conductor hardware appliance.
Ensure that you have the correct screws before installing the Mobility Conductor hardware appliance.
Installation Steps
To install a Mobility Conductor hardware appliance into a two-post 19-inch Telco rack:
1. Place the mounting bracket over the mounting holes on the appliance (see
Figure 5 Rack Mount Brackets- Standard
2. Secure the bracket to the appliance using the eight screws for the mount bracket (four per bracket) and a suitable screwdriver.
3. Mount the appliance within your organization’s rack system using the four screws for system rack mount (two per bracket) and a suitable screwdriver (see
Figure 6 Rack Mount Installation- Standard
Leave a minimum of 10 cm (4 inches) of space on the left and right side of the appliance for proper air flow and ventilation.
Leave additional space in the front and the back of the appliance to access network cables, LED status indicators, and power cord.
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Installation |
15
Rack Mount Installation- Mid
This mounting option allows mounting the Mobility Conductor hardware appliance from the middle in standard two-post 19-inch Telco rack. The mounting brackets can be used for this installation as well.
Each Mobility Conductor hardware appliance should have its own mounting equipment. Do not place other networking equipment directly on top of a mounted Mobility Conductor hardware appliance. Failure to do so can damage the device.
Required Tools and Equipment
The following tools and equipment are required for installing a Mobility Conductor hardware appliance:
Mounting Bracket (x2) (included in the kit)
Screws for mounting bracket (x8): M4 x 8 mm Phillips Flat Head Screws (included in the kit)
Screws for system rack mount (x4): M6 x 15 mm Phillips Pan Head Screws (included in the kit)
Suitable Screwdrivers for all screw types provided in the box (not included in the kit)
Some racks require screws that differ from those included with the Mobility Conductor hardware appliance.
Ensure that you have the correct screws before installing the Mobility Conductor hardware appliance.
Installation Steps
To install a Mobility Conductor hardware appliance from the middle in a standard two-point 19-inch
Telco rack:
1. Place the mounting bracket over the mounting holes on either side of the appliance in the middle
(see
Figure 7 Rack Mount Brackets- Mid
16
| Installation
2. Secure the bracket to the appliance using the eight screws for the mount bracket (four per bracket) and a suitable screwdriver.
3. Mount the appliance within your organization’s rack system using the four screws for system rack mount (two per bracket) and a suitable screwdriver (see
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
Figure 8 Rack Mount Installation- Mid
Leave a minimum of 10 cm (4 inches) of space on the left and right side of the appliance for proper air flow and ventilation.
Leave additional space in the front and the back of the appliance to access network cables, LED status indicators, and power cord.
Table or Shelf Installation
Required Tools and Equipment
Rubber Feet (included in the kit)
Installation Steps
1. Attach the rubber feet to the bottom of the appliance(see Figure 9 ).
Figure 9 Attaching Rubber Feet
2. Place the appliance in the location you have chosen.
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Installation |
17
Connecting and Disconnecting the AC Power Cord
Once you have installed the Mobility Conductor hardware appliance, you are ready to power On the device. The Mobility Conductor hardware appliance is not equipped with an On/Off switch. The device will power On when the AC power cord is connected to the power supply and an AC power outlet.
To connect the AC power cord to the Mobility Conductor hardware appliance:
1. Insert the coupler end of the AC power cord into the AC power connector on the power supply module.
2. Secure the AC power cord using the cable retention holder attached on the power supply module.
The Mobility Conductor hardware appliance should now be receiving power.
To disconnect the AC power cord from the Mobility Conductor hardware appliance:
1. Loosen the cable retention holder that is securely holding the AC power cord.
2. Pull the AC power cord from the power supply module.
If two power supply modules are installed in the appliance, disconnect AC power cord from both power supply modules to turn off the appliance.
The Mobility Conductor hardware appliance is now turned Off.
Installing and Removing a Fan Module
Use standard ESD precautions when installing or removing a fan module.
The fan module is field-replaceable and hot-swappable. Hot-swapping allows you to replace the fan module without having to power down the appliance.
1. Remove the old fan module.
a. Using a Phillips Head screwdriver, turn the screws on the fan module counter-clockwise until loose (they cannot be removed completely).
b. Use the fan module handle to pull the module out (see
).
Figure 10 Removing the Fan Module
18
| Installation
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
2. Align the new fan module with opening in the appliance.
Ensure that fan module is correctly aligned with the opening on the appliance. Failure to do so can result in damage to the fan module.
3. Insert the fan module into the appliance.
4. Turn the screws on the fan module clockwise until tight to secure the fan module into the appliance.
Installing and Removing a Power Supply
Use standard ESD precautions when installing or removing a power supply module.
The power supply modules are hot-swappable. Hot swapping allows you to replace a failed power supply without powering down the Mobility Conductor hardware appliance during the replacement process. This makes it unnecessary to shut down the Mobility Conductor hardware appliance during the replacement procedure.
Never insert or remove a power supply module while the power cord is connected to it. Verify that cord has been disconnected from the power supply before installation or removal.
Installing a Power Supply Module
To replace the failed power supply module with a new power supply module:
1. Remove the failed power supply module. For more details, see
2. Align the new power supply module with the opening in the appliance.
3. Slide the new power supply module into the appliance until the tab securely engages on to the appliance.
4. Insert the power cord in the AC connector on the power supply module and secure it. For more details, see
“Connecting and Disconnecting the AC Power Cord” on page 18
.
To replace the filler panel with a new power supply module:
1. Turn the screws on the filler panel counter-clockwise until loose (they cannot be removed completely).
2. Use the handle on the filler panel to pull it out.
3. Align the new power supply module with the opening in the appliance.
4. Insert the power supply module into the appliance until the tab securely engages on to the appliance.
5. Insert the power cord in the AC connector on the power supply module and secure it. For more details, see
“Connecting and Disconnecting the AC Power Cord” on page 18
.
Removing a Power Supply Module
To remove a power supply module from the Mobility Conductor hardware appliance:
1. Remove the power cord in the AC connector on the power supply module.
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Installation |
19
2. Pull the tab on the power supply module towards the left and slide it out using the handle (see
).
3. If you are not replacing the power supply module immediately, ensure to install a filler panel that was included with your Mobility Conductor hardware appliance. To install the filler panel: a. Align the filler panel with the opening in the appliance. b. Slide the filler panel into the appliance.
c. Turn the screws on the filler panel clockwise until tight to secure the filler panel into the appliance. (see
).
and proceed to
“Installing a Power Supply Module” on page 19
.
Figure 11 Removing a Power Supply Module
Figure 12 Installing a Filler Panel
20
| Installation
Connecting and Removing an SFP/SFP+/LC Cable
SFP/SFP+ modules are collectively referred as SFP modules in this section.
Use standard ESD precautions when installing or removing an SFP.
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
Connecting an SFP Module
To connect an SFP module into the Mobility Conductor hardware appliance, slide the SFP module, top side facing upward, into a 10GBase-X (SFP+) port until a connection is made and an audible click is heard (see Figure 13 ).
Figure 13 Installing an SFP
Removing an SFP Module
To remove an SFP module:
1. Open and release the latch on the SFP module.
2. Pull and remove the module from the port.
Connecting an LC Cable
To connect an LC cable into an SFP module:
1. Clean the LC fiber optic cable connector before inserting it into the SFP module.
2. Insert the LC fiber optic cable into the SFP module. Ensure that the latch on the cable faces the top of the SFP module (see Figure 14 ).
3. Slide the cable into place until a connection is made and an audible click is heard.
Disconnecting an LC Cable
To disconnect an LC fiber optic cable from an SFP module, depress the transceiver handle to release the latch on the cable and simultaneously pull the cable out of the port.
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Installation |
21
Figure 14 Connecting or Removing an LC Fiber Optic Cable
22
| Installation
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
Chapter 3
Specifications, Safety, and Compliance
Mobility Conductor Hardware Appliance Specifications
Physical
Device Dimensions (without mounting brackets) (HxWxD): 1.73” x 17.40” x 15.79” (4.4 cm x 44.2 cm x 40.1 cm)
Device Weight: 15.87 lbs (7.2 kg)
Power Supply Specifications
400W AC Power Supply
AC Input Voltage: 100 VAC to 240 VAC
AC Input Current: 6.0 A max
AC Input Frequency: 50 to 60 Hz
Operating Specifications
Operating Temperature Range: 0 °C to 40 °C (32 °F to 104 °F)
Operating Humidity Range: 10% to 90% (RH), non-condensing
Storage Specifications
Storage Temperature Range: –40 °C to 70 °C (-40 °F to 158 °F)
Storage Humidity Range: 10% to 95% (RH), non-condensing
Operating Altitude
Operating Altitude Range: 0 to 10,000 feet
Regulatory Model Name
The regulatory model name for the Mobility Conductor hardware appliance is ARCNMMHW.
Safety and Regulatory Compliance
Aruba Networks, Inc. provides a multi-language document that contains country-specific restrictions and additional safety and regulatory information for all Aruba products. This document can be viewed or downloaded from the following location: www.arubanetworks.com/safety_addendum
Aruba appliances must be installed by a professional installer. The professional installer is responsible for ensuring that grounding is available and it meets applicable local and national electrical codes.
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Specifications, Safety, and Compliance |
23
CLASS 1
LASER PRODUCT
Use of controls or adjustments of performance or procedures other than those specified in this manual may result in hazardous radiation exposure.
This product complies with 21 CFR 1040.10 and 1040.11 (except for deviations pursuant to Laser Notice
No. 50, dated June 24, 2007) and with IEC 60825-1.
For continued compliance with the above laser safety standards, only approved Class 1 modules from our approved vendors should be installed in the product.
Although this appliance has been tested up to 1kV per CE immunity requirements, this product requires surge protection to be provided as part of the building installation to protect against unidirectional surges resulting from electrical switching and lightning strikes.
For protection against these surges in an outdoor installation, any exposed wiring must be shielded, and the shield for the wiring must be grounded at both ends.
Electromagnetic Interference
United States
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This product complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Canada
This Class A digital apparatus complies with Canadian ICES-003.” & “Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Europe
This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.
24
| Specifications, Safety, and Compliance
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
Japan VCCI
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take corrective actions.
Taiwan (BSMI)
EU Regulatory Conformance
This product is CE marked according to the provisions of the EMC Directive (2004/108/EC)
- CE. Aruba Networks Inc., hereby declares that Mobility Conductor hardware appliance device models are in compliance with the essential requirements and other relevant provisions of Directive (2004/108/EC). CE The Declaration of Conformity made under Directive 1999/
5/EC is available for viewing at the following location in the EU community.
Battery Statements
The battery supplied with this product may contain perchlorate material. Special handling may apply in
California and other certain states. See www.dtsc.ca.gov/hazardouswaste/perchlorate for more information.
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
Risque d’explosion si la batterie est remplacée par une batterie de type incorrect. Mettez les batteries au rebut conformément aux instructions.
Other Safety Compliance
Shock hazard. Disconnect both power cords to remove power.
For indoor use only. The appliance, AC power cord, and all connected cables are not designed for outdoor use.
Aruba Mobility Conductor Hardware Appliance
| Installation Guide Specifications, Safety, and Compliance |
25
Proper Disposal of Aruba Equipment
Waste of Electrical and Electronic Equipment
Aruba products at end of life are subject to separate collection and treatment in the
EU Member States, Norway, and Switzerland and therefore are marked with the symbol shown at the left (crossed-out wheelie bin). The treatment applied at end of life of these products in these countries shall comply with the applicable national laws of countries implementing Directive 2002/96EC on Waste of Electrical and
Electronic Equipment (WEEE).
European Union RoHS
Aruba products also comply with the EU Restriction of Hazardous Substances
Directive 2002/95/EC (RoHS). EU RoHS restricts the use of specific hazardous materials in the manufacture of electrical and electronic equipment. Specifically, restricted materials under the RoHS Directive are Lead (including Solder used in printed circuit assemblies), Cadmium, Mercury, Hexavalent Chromium, and Bromine. Some Aruba products are subject to the exemptions listed in RoHS Directive Annex 7 (Lead in solder used in printed circuit assemblies). Products and packaging will be marked with the “RoHS” label shown at the left indicating conformance to this Directive.
India RoHS
This product complies with RoHS requirements as prescribed by E-Waste (Management & Handling)
Rules, governed by the Ministry of Environment & Forests, Government of India.
China RoHS
Aruba products also comply with China environmental declaration requirements and are labeled with the “EFUP 50” label shown at the left.
ㇱઙฬ⒓
(Parts)
䪙
Lead
(Pb)
Ქኂ‛ ჿ
Hazardous Materials Declaration
ᳮ
Mercury
(Hg)
Ქኂ‛ 䋼 ᚗర⚛ Hazardous Substances)
䬝
Cadmium
(Cd)
ચ 䫀
Chromium VI
Compounds
(Cr
6+
)
ᄙ ⒈ 㘨 ⧶
Polybrominated
Biphenyls
(PBB)
ᄙ ⒈ ੑ ⧶ 䝮
Polybrominated
Diphenyl Ether
(PBDE)
⬉ 〝᧼
PCA Board
᪾ 㒘 ઙ
Mechanical
Subassembly
X O
X O
O
O
O
O
O
O
O
O
⬉ Ḯㅎ㈩ེ
Power Adaptor
X O O O O O
O: ␜ 䆹 Ქኂ‛ 䋼 䆹 ㇱઙᚲဋ 䋼 ᧚ᢱਛ⊛㊂ဋ SJ/T11363-2006 ᷛ ಎ 㾘 ቯ⊛㒢㊂ⷐ᳞એਅޕ
This component does not contain this hazardous substance above the maximum concentration values in homogeneous materials specified in the SJ/T11363-2006 Industry Standard.
X: ␜ 䆹 Ქኂ‛ 䋼 ⥋ዋ 䆹 ㇱઙ⊛ᨱ৻ဋ 䋼 ᧚ᢱਛ⊛㊂ SJ/T11363-2006 ᷛ ಎ 㾘 ቯ⊛㒢㊂ⷐ᳞ޕ
This component does contain this hazardous substance above the maximum concentration values in homogeneous materials specified in the SJ/T11363-2006 Industry Standard.
ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ䖭ѯ⠽䋼 ޕ
This table shows where these substances may be found in the supply chain of electronic information products, as of the date of sale of the enclosed product.
ℸᷛᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳᷛᖫ ᶤѯ䳊䚼ӊӮ᳝ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ՟བ⬉∴ऩܗഫ䌈݊ѻકϞ
ℸ⦃ֱՓ⫼ᳳ䰤া䗖⫼ѢѻકᰃѻકݠЁ᠔㾘ᅮⱘᴵӊϟᎹ
The Environment- Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here. The Environment- Friendly Use Period is valid only when the product is operated under the conditions defined in the product manual.
26
| Specifications, Safety, and Compliance
Aruba Mobility Conductor Hardware Appliance
| Installation Guide
ดาวน์โหลด
โฆษณา