Yale 7250M Exit Device Installation Instructions
Yale 7250M is the SquareBolt Exit Device Series designed to enhance the safety and security of various door types, including single doors and pairs with mullions. This versatile device offers a range of features and use cases that cater to different needs.
The Yale 7250M is equipped with a dogging feature that allows you to hold bolts retracted and the touchpad depressed, making it ideal for push-pull door operations. It also offers the option to install a raised glass kit or windstorm kit, providing flexibility for specific door designs and environmental conditions.
The device is compatible with Yale 500F, 510F, or 480F, allowing for seamless integration with these popular models. Additionally, it comes with a variety of fasteners to accommodate different door and frame materials, ensuring a secure and reliable installation.
Advertisement
Advertisement
Installation Instructions
(Single Doors or Pairs with Mullion)
Patent 5,605,362
For Doors of Either Hand
RHR Door LHR Door
Outside Trim
Device is packed ready for any Yale
500F, 510F or 480F.
757F Strike
Locking Plate
Shim
(2) 10-24 PFHMS
Fire Rated Application
757F Strike
(Standard for
Fire Rated product)
7250M: Panic Label
7250MF: Fire Label
7250M(F)WS: Windstorm Label
Packed for reinforced metal doors. Optional sex nuts required for composite, wood and unreinforced metal doors.
NOTE: These installation instructions cover only standard products. To install options use installation instructions packed with optional component, or contact the factory.
(4) 1/4-20 x 1" PPHMS
(Special Head)
Interlock Bracket
Supplied With
Fire Mullion
(3) 10-24 PFHMS
(4) 10-24 PFHMS
Windstorm Application
757(F)WS Strike
(Standard for
Windstorm product)
Interlock Bracket
Supplied With
Windstorm Device
(4) 10-24 PFHMS
(4) 10-24 PFHMS
Reinforced End Clamp
End Clamp
(3) 8-32 x 5/16" PFHUMS
(2) 1/4-20 x 1" PPHMS
(Special Head)
Dogging Key
Hole Plug
(Fire Devices)
Dogging
Feature to hold bolts retracted and touchpad depressed, for push-pull door operation.
To Dog Device
1. Insert dogging key.
2. Hold touchbar depressed.
3. Turn key 1/4 turn clockwise.
(Not a feature of fire labeled devices.)
Cover
630, 629
605, 606, 609, 618, 620, 625, 626,
611, 612, 613, 616, 693, 722
(2) 8-32 x 5/16" PFHUMS
ABBREVIATION
PPH”F”TCS
PRHMS
PFHMS
PFHUMS
FASTENER DESCRIPTION
PHILLIPS PAN HEAD TYPE “F” THREAD CUTTING SCREW
PHILLIPS ROUND HEAD MACHINE SCREW
PHILLIPS FLAT HEAD MACHINE SCREW
PHILLIPS FLAT HEAD UNDER CUT MACHINE SCREW
Attention Installer
End Cap
Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Yale Locks &
Hardware makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having
Jurisdiction) to ensure compliance with all applicable codes and ratings.
All dimensions are in inches (mm) unless otherwise noted.
80-9470-0250-000 (04-13)
An ASSA ABLOY Group brand
Shim Kit Options 1/4-20 Sex Nut Option Maintenance
7250M Windstorm Kit: Model Number: 723NSWS
Black Finish
Kit consists of (3) Latch Head Shims (Device Cover seats on shims), (3) End Clamp Shims (End Cap seats on shims), and longer fasteners.
Note: Shim Kit required for Windstorm application.
Raised Glass Kit: Model Number: 723NS Black Finish
Kit consists of Latch Head Shim (Device Cover seats on shim) and End Clamp Shim (End Cap seats on shim).
More than two Shim Kits require longer device mounting screws (not included).
Each shim is 1/8" (3.2) thick.
Specify Finish
Standard for Fire Rated
Doors. Recommended for unreinforced metal doors and wood door applications.
Note: Required on
Windstorm application for
Latch Head mounting.
Device
No Trim
With Trim
Quantity
8
6
Size Part Number
1/4-20 66-0001-1745
Fire Mullion
(Add)
4 10-24 60-2000-1088
1.
Periodically remove covers and coat mechanisms with a silicone base lubricant.
This is particularly required in corrosive environments for proper product function.
2.
Check mounting fasteners periodically.
Retighten if found loose. Apply screw locking compound (available at automotive part stores) or change part fasteners if screws continue to back out.
3.
Periodic checks and adjustments of rods mayb be required to compensate for changes in the opening (e.g.: door sagging, etc.).
Check Before Starting
Unreinforced Doors or Frames
Doors and Frames with walls having a structural thickness (metal skin plus reinforcement or solid hardwood) to engage less than (3) full screw threads are considered unreinforced.
Unreinforced Doors: Use SNB (sex nuts and bolts).
Unreinforced Frames: Use Blind Rivet Nuts.
Recommended fasteners for unreinforced openings are not necessarily supplied by Yale Locks and
Hardware.
Min. Door Stile
4-1/2" (114mm)
Door and frame must meet structural and dimensional specifications on exit device template(s) for door and frame preparation.
Reinforcement
Door Skin Blind Rivet Nut
Door Must Swing Freely
1. Mark Door
Locate and Mark Horizontal and Vertical
Reference Centerlines as shown.
Note: For Pair without Mullion follow instructions packed with 793 Strike.
LHR DOOR
INSIDE FACE
1-5/8
(32)
CL Vertical
Reference
CL
Horizontal
Reference
STOP FACE
Typical Single Swing
39-15/16
(1014)
FINISHED
FLOOR
RHR DOOR
INSIDE FACE
1-5/8
(32)
Vertical
Reference
CL
CL
Horizontal
Reference
LHR DOOR
INSIDE FACE
1-5/8
(32)
CL Vertical
Reference
CL
Horizontal
Reference
MULLION FACE MULLION FACE
Pair with Mullion
2. Prepare Door & Frame
A.
Seat template on door and stop faces.
B.
Align template with horizontal and vertical device centerline on door. Tape template in place.
C. Locate and tape Trim template on door. (See instructions packed with trim.)
D.
Spot and prepare holes.
Device: (2) 1/4-20 Machine Screws*, or (2) 3/8" (9.5) Dia Sex Nuts and Bolts.
Strike: (2) 10-24 Machine Screws, or (2) #10 Wood Screws.
Note: (*)Metal reinforced doors only.
Caution: The use of Shims (i.e.; Raised Glass or Windstorm) requires shifting location
of Strike away from the door. (See Door Marker Template for details).
1-1/4
(32)
Min. Stop
CL
Vertical
Reference
LHR DOOR
INSIDE FACE
CL Horizontal
Reference
2
80-9470-0250-000 (04-13)
An ASSA ABLOY Group brand
3. Size Device
Device must be field cut to size unless standard opening and device are 36" (0.91m).
LHR DOOR
INSIDE FACE
Align mounting holes in door with mounting holes in device
Align horizontal line on door with edge of device
Dogging Hole
No gap between end cover & touch bar
Mark cutoff line.
Cut square on line.
Min. to Stile Edge
1/2
(13)
1-15/16
(49)
Standard
1-11/16
(43)
Minimum
4. Clear Raised Door Molding
Device must seat flush on door surface or on shims that keep it parallel to door face.
(1) Shim Kit #723NS per 1/8" (3mm) of raised molding
(1) Shim Kit #723NS required for each
1/8" (3mm) of device lift needed. Longer device mounting screws needed when more than (2) shim kits are used. See
Shim Kits Option on page 2.
5. Install Device
C D
1/2
(13)
1-1/4
(32)
B
Device Screws
(Bolt to door reinforcement, sex nuts, or trim studs)
A. Mount trim (follow instructions packed with trim).
B. Seat bar in place. Fasten device head (2 PRHMS or SNB).
C. Set bar level. Locate end clamp holes.
D. Prepare end clamp mounting holes. Mount end clamp.
2 #1/4-20 PRHMS or 3/8" (10) dia. SNB
E. Check bolt retraction.
1. Depress touchbar (bolts must retract). Release touchbar
(bolts must extend).
2. Actuate trim (bolts mush retract). Release trim actuator
(bolts must extend).
3. (NOT FOR FIRE DEVICES). Depress touchbar, turn dogging key clockwise (bar must remain depressed, bolts must remain retracted). Turn dogging key counterclockwise (bar and bolts must return to extended position).
NOTE: When resulting operation is faulty, check first for visible binding or interference. If there is no apparent reason for the fault, remove item from the door and recheck its operation before assuming that it is defective.
F. Tighten all mounting screws.
3
80-9470-0250-000 (04-13)
An ASSA ABLOY Group brand
6. Install Strike
3/16 ± 1/32
(4.0 - 5.6)
Detail A
Detail B
Bolt Fully Extended
Tangent to Roller
(MUST)
(2) 10-24 x 3/4"
PFHMS
757(F)(WS) Strike
(Shim as required)
Detail C
(757 Strike)
A. Position strike projection (strike + locking plate + shims, if needed).
See Detail A.
B. Position strike depth. See Detail B.
C. Fasten strike securely, as shown on Detail C.
D. Check bolt engagement.
1. Bolt should retract to clear the strike, when actuated by bar, trim, or dogging action. Bolt should consistently reengage the strike, when actuators are released and the door shuts.
2. Door should remain latched and not rattle when pushed, pulled, or shaken in/out.
E. Lock strike into place. For Fire application see Detail E1, for
Windstorm application see Detail E2.
1. Fire Strike Application: Spot and prepare (1) hole using the strike as a template and install strike center screw (1) 10-24 x 3/4" PFHMS.
2. Windstorm Strike Application: Spot and prepare (2) holes using the strike as a template. Drill through the strike shims and locking plate (when required), then install (2) 10-24 x 1"
PFHMS strike locking screws.
F. Install interlock bracket (Fire Mullion). See Detail F.
1. Position strike interlock bracket in place, as shown. Locate bracket holes.
2. Prepare interlock bracket mounting holes. mount interlock bracket using (43) 10-24 x 1" PFHMS or SNB).
NOTE: Interlock bracket and screws supplied with fire mullion.
G. Install interlock bracket (Windstorm Device). See Detail F.
1. Position strike interlock bracket in place, as shown. Locate bracket holes.
2. Prepare interlock bracket mounting holes. Mount interlock bracket using (4) 10-24 x 1" FHMS or SNB).
NOTE: Interlock bracket and screws supplied wtih Windstorm
Product supercedes interlock bracket supplied wtih Fire
Mullion (remove and discard when applicable).
Detail E1
(757F Strike)
Strike Locking Screws
(2) 10-24 x 1" PFHMS
Strike Center Screw
(1) 10-24 x 3/4" PFHMS
Detail E2
(757(F)WS Windstorm Strike)
5/16
(8)
7. Install Cover & End Cap
(2) 8-32 PFHUMS
(3) 8-32 PFHUMS
Detail F
Device, Strike &
Interlock Bracket
4
80-9470-0250-000 (04-13)
An ASSA ABLOY Group brand
7250M(F)(WS) Series
Square Bolt Exit Devices
Template
Frame Stop or
Mullion Face
(Strike Seat)
Adjust Hole "B" location equal to the thickness of shims required.
B
5/8
(16)
1-11/32
(34)
3-5/8
(92)
A
CL
VERTICAL
REFERENCE & DEVICE
X
*7250M(F)(WS) ONLY
Door Inside
Face Surface
( Device Seat)
1-1/4
(32) 3/4 (19) Dia.
x 1/4 (6) Deep
CL
HORIZONTAL
REFERENCE & DEVICE
1-11/32
(34)
1-1/4
(32)
B
5/8
(16)
Adjustment for
Raised Glass and
Windstorm Applications
ONLY
Notes:
1. Unreinforced Frames require that 10-24 blind rivet nuts (by others) be used to bolt strike.
Frames are considered not reinforced when strike mounting screws cannot engage (3) full threads.
2. Dimensions are given in inches (mm).
3. CAUTION: Office copiers, printers and facsimile machines may change the size of a drawing and make the template inaccurate to use as a door marker.
LHR Door
1-5/8
(41)
3-5/8
(92)
X
*7250M(F)(WS) ONLY
A
HOLE DOOR/FRAME FASTENER
A, X*
B
PREPARATION
Metal Reinforced
All Others
Metal Reinforced
Solid Hardwood
All Others
1/4-20 PRHMS
Drill: #7 (.201" dia.)
Tap: 1/4-20
1/4-20 SNB
10-24 PFHMS
#10x1-1/4" PFHWS
See Note 1
3/8" (9.5mm) dia.
Thru door
Drill: #26 (.147" dia.)
Tap: 10-24
Pilot Hole: 11/64"
(4.40mm) dia.
As required for blind nut used.
5
80-9470-0250-000 (04-13)
An ASSA ABLOY Group brand
An ASSA ABLOY Group brand
This page left blank intentionally.
6
80-9470-0250-000 (04-13)
Door Inside
Face Surface
( Device Seat)
A
CL
VERTICAL
REFERENCE
& DEVICE
X
*7250M(F)(WS) ONLY
3-5/8
(92)
5/8
(16)
7250M(F)(WS) Series
Square Bolt Exit Devices
Template
Frame Stop or
Mullion Face
(Strike Seat)
Adjust Hole "B" location equal to the thickness of shims required.
B
1-11/32
(34)
CL
HORIZONTAL
REFERENCE & DEVICE
3/4 (19) Dia.
x 1/4 (6) Deep
1-1/4
(32)
1-1/4
(32)
1-11/32
(34)
X
*7250M(F)(WS) ONLY
1-5/8
(41)
5/8
(16)
B
Adjustment for
Raised Glass and
Windstorm Applications
ONLY
3-5/8
(92)
A
HOLE DOOR/FRAME FASTENER
A, X*
B
PREPARATION
Metal Reinforced
All Others
Metal Reinforced
Solid Hardwood
All Others
1/4-20 PRHMS
Drill: #7 (.201" dia.)
Tap: 1/4-20
1/4-20 SNB
10-24 PFHMS
#10x1-1/4" PFHWS
See Note 1
3/8" (9.5mm) dia.
Thru door
Drill: #26 (.147" dia.)
Tap: 10-24
Pilot Hole: 11/64"
(4.40mm) dia.
As required for blind nut used.
An ASSA ABLOY Group brand
Notes:
1. Unreinforced Frames require that 10-24 blind rivet nuts (by others) be used to bolt strike.
Frames are considered not reinforced when strike mounting screws cannot engage (3) full threads.
2. Dimensions are given in inches (mm).
3. CAUTION: Office copiers, printers and facsimile machines may change the size of a drawing and make the template inaccurate to use as a door marker.
RHR Door
FLIP TO OTHER SIDE FOR RHR DOOR
7
80-9470-0250-000 (04-13)
Product Support Tel 800.438.1951 • www.yalelocks.com
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
Yale® and SquareBolt® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group company. Other products' brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. These materials are protected under U.S. copyright laws. All contents current at time of publication.
Yale Security Inc. reserves the right to change availability of any item in this catalog, its design, construction, and/or its materials.
Copyright © 1999, 2013, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
8
80-9470-0250-000 (04-13)
An ASSA ABLOY Group brand

Public link updated