Elkay LK4593 Outdoor Stone Fountain Wall Mount Non-Filtered Owner's Manual
Advertisement
Advertisement
4592_FTN 4593_ FTN LK4593_FTN
Owners Manual
Wall Mount Stone Fountains
Installer
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS,
ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE
BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE
ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH
CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY
DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO
ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER INLET
NOTE: WATER FLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
FIG. 1
PAGE 1
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS
SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
FIG. 2
97215C (Rev. SIE - 1/11)
4592_FTN 4593_FTN LK4593_FTN
4592 ROUGH-IN
LEGEND:
A = RECOMENDED WATER SUPPLY LOCATION, 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM
WALL SHUT OFF VALVE BY OTHERS.
B = RECOMMENDED LOCATION FOR WASTE OUTLET, 1-3/4" O.D. (44mm) DRAIN.
C = (4) 5/16" (8mm) DIA. MOUNTING HOLES.
GENERAL INSTRUCTIONS
1. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/4" O.D. Contractor to supply waste trap and
service stop valve in accordance with local code.
2. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign
matter before being connected to fountain. This fountain is manufactured in such a manner that it does
not in anyway cause taste, odor, color, or sediment problems.
3. Connect fountain to building supply line with a shut-off valve and install a 3/8" unplated copper waterline
between the valve and the fountain. Remove any burrs from outside of water line and insert into inlet side
of the strainer (see Fig.1) to a positive stop - approximately 3/4". (see Fig.2) DO NOT SOLDER TUBES
INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
4. These products are designed to operate on 20 psig to 105 psig supply line pressure. If inlet pressure is
above 105 psig, a pressure regulator must be installed in the supply line. Any damage caused by reason
of connecting this product to supply line pressures lower than 20 psig or higher than 105 psig is not
covered by warranty.
INSTALLATION INSTRUCTIONS
1. This fountain is to be mounted on a smooth, flat, finished wall surface with adequate support structure.
NOTE: Wall mounting structure must be capable of supporting 300 lb. load on fountain.
2. Establish rim height that fountain is to be mounted at.
3. Refer to rough-in for plumbing.
4. Locate and install trap. (trap not furnished)
5. Install shut-off valve on building water supply. (valve not furnished)
6. Locate and install fountain using 3/8" minimum lag screws or bolts. (screws or bolts not furnished)
7. Connect water supply and fountain drain.
8. Turn on water supply and check all connections for leaks.
97215C (Rev. SIE - 1/11) PAGE 2
4592_FTN 4593_ FTN LK4593_FTN
4593 ROUGH-IN
LEGEND:
A = RECOMENDED WATER SUPPLY LOCATION, 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM
WALL SHUT OFF VALVE BY OTHERS.
B = RECOMMENDED LOCATION FOR WASTE OUTLET, 1-3/4" O.D. (44mm) DRAIN.
C = (4) 5/16" (8mm) DIA. MOUNTING HOLES.
SUGGESTED CONFIGURATION FOR EXPOSED MOUNTING BOLTS
ACORN NUT
WASHER
CLOSET SCREW
OR THREADED ROD
(DEPENDING ON WALL TYPE
AND ANCHOR USED)
FIG. 3
PAGE 3 97215C (Rev. SIE - 1/11)
17
18
19
20
12
13
14
15
16
ITEM
NO.
1
2
3
4
5
6
7
8
9-A
9-B
10
11
8
4592_FTN 4593_FTN LK4593_FTN
ITEMIZED PARTS LIST 9A
PART NO.
100147140560
100322740560
101570540560
15005C
15013C
170705042830
40048C
40089C
400942308640
98287C
40169C
50986C
55996C
56092C
56121C
600985551640
61313C
66346C
70683C
75588C
75589C
DESCRIPTION
Drain Gasket
Bubbler Gasket
Drain Gasket
Regulator Retaining Nut
Bubbler Tube Assy.
Basin
Button
Nut - Cover
Bubbler
Bubbler Assembly
Hex Nut 1-5/16"-20UN
Regulator Holder
In-Line Strainer
Poly Tubing (Cut To Length)
Drain Elbow
Drain Plug Assy.
Regulator
Drain Tube
Union - 1/4
Slip Joint Nut 1-1/4
Gasket
13
15
6
2
5
See
Fig. 4
4 10
13
7 16
FIG. 4
11
2
18
3
9B
1
14 20 19
4593 SHOWN
17
12
STREAM HEIGHT ADJUSTMENT: Stream height is factory set at
35 PSI. If supply pressure varies greatly from this, remove items 7 and 8 (see Fig.4) and adjust screw on item 16.
Clockwise adjustment will raise stream and counterclockwise adjustment will lower stream. For best adjustment, stream should hit basin approx. 6-1/2" from bubbler.
FIG. 5
TROUBLE SHOOTING AND MAINTENANCE
Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from
the orifice with a small round file not over 1/8" diameter or small diameter wire.
CAUTION: DO NOT file or cut orifice material.
Stream Regulator: If orifice is clean, regulate flow as in “Stream Height" instructions above. If replacement is necessary,
see parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal.
To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing. (See Fig.2)
To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4".
PRINTED IN U.S.A.
97215C (Rev. SIE - 1/11)
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620