Hydreon RG-11 Installing Manual
Hydreon RG-11 is an optical rain gage that accurately measures precipitation by relying on a sophisticated optical sensor that differentiates between raindrops and non-rainfall events. This advanced technology eliminates false triggering caused by factors such as insects, birds, or debris, ensuring reliable rainfall detection.
The Hydreon RG-11 offers various operational modes to cater to diverse application needs:
"It's Raining" Mode: Detects rainfall intensity and activates an output to indicate the presence of rain. Adjustable sensitivity levels allow for customization based on specific requirements, ranging from detecting drizzle to heavy downpours.
Advertisement
Advertisement
MODEL RG-11
OPTICAL RAIN GAGE
!
LENS
SHADE
NOTCHES IN RING
MATE WITH
RIBS IN LENS
O-RING
STRETCH BEFORE
INSTALLING
!
MOUNTING ARM
CUT OFF FOR
CONDUIT-MOUNT
EXPLODED VIEW
LED ON BOARD
ON when OUT is active
PRINTED-CIRCUIT
BOARD (PCB)
HOUSING
VERY IMPORTANT
SCREWS
(4 OF #6 X 1”)
Stretch the O-ring a few times, so that it fits easily into the groove on the lens.
After the unit is assembled, verify that the O-ring is properly seated by confirming that you can see it through the lens, all the way around. The O-ring is slightly under-sized for the groove because that gives the optimal seal.
INSTALLING THE RAIN SENSOR
Mount the rain gage where it gets a clear measurement of precipitation– away from overhangs, etc.
The mounting arm is designed to fit over a strap 0.75”
(19 mm) wide. Two 0.25” (holes 6.35 mm) are placed
0.75” (19 mm) part.
The gland style connector goes in the bottom hole. Be sure to use wire rated for outdoor (high-UV) use.
For conduit applications, the mounting arm may be removed, and the wiring hole drilled out using a step drill to accommodate a ½” EMT compression connector or similar style of conduit connector.
Assemble the device as shown. Stretch and release the silicone o-ring (size -036) a few times, so it fits easily in the groove. Optionally, you may coat the O-ring and screws with silicone grease.
Set the DIP switches to the desired mode, and the desired adjustment within that mode. (See detailed discussion following)
The Rain Gage must be assembled when dry. Any water trapped inside can condense and cause corrosion.
You may optionally add extra desiccant packets (not supplied.) If the Rain Gage is not subject to splashing or sprayed water, you may optionally vent the enclosure by drilling a 1/8” (3 mm) hole in the bottom of the case.
.38
9.53
.75
19.05
.41
10.40
.75
19.16
.25
6.40
2.78
70.71
4.73
120.23
2.17
55.20
!
- APPLICATION WARNING -
Do not use the RG-11 in any application where the false indication of water or a missed valid detection of water could cause damage to life or property. It is the responsibility of the system designer / integrator to design redundancy into the system so that the failure of any one component, including the RG-11 or other sensor, does not result in disaster. The manufacturer of the RG-11, Hydreon Corporation, will in no way be liable for consequential damages due to the failure or false indication of one of its sensors.
RAIN GAGE CONNECTIONS
INTERFACE
TERMINAL
BLOCK
RG-11
PWR1
PWR2
NC
NO
COM
POWER IN
(AC OR DC)
RELAY
CONTACTS
SWITCH ON
12345678
PROGRAMMING
DIP SWITCH
PROGRAM /
COMMUNICATIONS
CONNECTOR
(NOT USED IN MOST
APPLICATION)
RAIN GAGE WIRING EXAMPLES
LINE VOLTAGE CONTROL “IT’S RAINING” APPLICATION
120 VAC
LINE IN
COM
NC OPERATOR
SWITCH
24 VAC
TRANSFORMER
24 VAC
NO
COM
OPEN
CLOSED
MOTORIZED
DAMPER
DC OR
AC IN
RAIN
SENSING
CIRCUITS
PWR1
PWR2
NC
NO
COM
RELAY CONTACTS
MAX 1 A,
24V DC OR AC
EQUIVALENT SCHEMATIC
- The relay output of the RG-11 is rated for 24V AC or DC, at 1 A. Thus, the RG-11 cannot drive a line voltage
(120 VAC) load without an external relay.
-The RG-11 requires a low voltage AC or DC supply and may not be directly powered from the 120 VAC line.
RG-11
PWR1
PWR2
NC
NO
COM
SWITCH ON
For this example, these switches are on:
SW 5 - Sets the sensor to
“It’s Raining’ mode.
SW 3 - Monostable extend output for 15 mintues.
TIPPING BUCKET
REPLACEMENT EXAMPLE
12345678
RG-11
PWR1
PWR2
NC
NO
COM
SWITCH ON
12345678
LOW VOLTAGE
“IT’S RAINING”
APPLICATION
+
-
12V DC
POWER
SUPPLY
COM
Shown are switches 1, 2, and
5 on => only turn on in a heavy rainfall.
RUN
12V DC, 1 A
OR LESS,
MOTOR THAT
RUNS WHEN
IT IS RAINING.
RG-11
PWR1
PWR2
NC
NO
COM
SWITCH ON
12345678
+
-
12V DC
POWER
SUPPLY
COUNTER
E.G. Red Lion Cub-3
In many cases, the RG-11 may directly replace tipping buckets in existing systems.
The switch settings shown here- all off– will emulate a tipping bucket of 0.01”
Specifications
disabled in Condensation sensing mode and in irrigation mode.
The unit will not read the DIP switches during sleep.
Parameter Value
Input Voltage 9 – 30VDC or
9 – 26 VAC
50V surge
Reverse polarity protected to 50V
In the tables, 1 = Switch on, 0 = Switch off, X = switch in either position.
OUT LED The LED in the center of the circuit board turns on when
OUT is on, as an aid to debugging.
Current Drain 15 mA nominal. (No outputs on, not raining, no heater) about 1.5 mA in micro-power sleep mode.
50 mA with output on.
55 mA - With heater on, 24V dc input.
Condensation -- Generally, the RG-11 will sense condensation as if it were rainfall, but this seldom amounts to a significant accumulation of water. The built-in low power heater (DIP SW 8 off) will tend to reduce condensation.
Output Relay closure, Normally Open and
Normally Closed contacts.
Max load 1A, 24 VDC.
Ambient Light Interference-- The RG-11 is almost completely immune to the effects of ambient light, and may freely be mounted in direct sunlight.
Operating
Temperature range
-40 C to +60C
Heater Notes– A built-in low power (0.25W) heater extends operation of the device to freezing (32 F or 0C). This is disabled if the micro-power (SW 8) is enabled. Note that this is a very modest amount of power; it will tend to drive off a modest amount of frost, but will not melt ice.
DIP Switches
Set the DIP switches for the application according to the table below. Generally, a few switch positions (5, 6, and 7) set the overall mode of operation, and others (1, 2, 3, 4) adjust the behavior within the modes. DIP Switch settings below correspond to software part number: 45-005-006 (SW 006)
Dark Sensing - Turns output on when it is dusk-- nominally less than 2000 lux. This is for applications such as retracting sunshields in the evening, when they are not needed. (Only in Mode
1, “It's Raining” applications.)
Switch 8 is Enable Micro-power Sleep Mode.
Most applications will use SW 8 off. If micro-power is enabled, the low-power heater is disabled. In micropower mode, if a long time (about 20 min) has elapsed since the last rain was detected, the unit will enter a less sensitive sleep mode. A large drop will cause it to exit sleep mode and resume normal operation. This is for battery or solar powered applications. Micro-power mode is
Mode 0-Tipping Bucket
Rain Gage emulates a tipping bucket of the specified size.
Switch
7 6 5 4 3 2 1
Behavior
0 0 0 X 0 0 0 Bucket Size = 0.01”
0 0 1 Bucket Size = 0.001” (Sensitive)
0 1 0 Bucket Size = 0.0001” (Very sensitive)
1 0 0 Bucket Size = 0.2 mm
1 0 1 Bucket Size = 0.01 mm (sensitive)
1 1 0 Bucket Size = 0.001 mm (Very sensitive)
1 1 1 1 Reserved for system test
In tipping bucket mode, the Rain Gage effectively emulates a tipping bucket of the specified size. For example, if the DIP switches are set to a tipping bucket mode with a bucket size of
0.01", then the output will pulse ON for 50mS each time 0.01" of water accumulates, just as a tipping bucket would. This can be externally totalized, and used to measure rainfall rates. Bucket sizes of 0.001" and 0.0001" are similar, generating pulses at accumulations of one one-thousandth, and one ten-thousands of an inch, respectively. These emulate what a tipping bucket would do if it were possible to make one that small. Metric bucket sizes are available as well, or the Inch unit scales may be scaled with external equipment.
Rain Gage Model RG-11 Instructions
PN 55-005-100 rev 6
Mode 1-It's Raining
Rain Gage turns on the relay to indicate that it is raining when the rainfall has reached a given intensity.
Switch
7 6 5 4 3 2 1
Function enabled, open, closed, and so forth depending on whether or not it is raining. The output turns on when a given rate of rainfall is detected, and turns off after it has dropped below a threshold.
Each of the sensitivity levels (set by switches 1 and 2) provides different trip and release points. There is much hysteresis built in, but real rain fall rates typically fluctuate, even in what you may perceive as a “steady rain”, so expect the output to turn on and off.
The output will remain on for between about 30 seconds and 5 minutes after the last detected rain drop, depending on sensitivity setting and actual conditions.
0 0 1 X X 0 0 Very sensitive-- first detected raindrop.
0 1 Sensitive-- turn on with very light rainfall
1 0 Medium Sensitivity-- turn on with medium rain (You would want your car's wipers on steady slow)
To prevent some piece of equipment from turning constantly on and off (or opening / closing, etc.) you can enable the Monostable extend (Switch 3). That will hold the output on for 15 minutes after the rain has ceased.
1 1 Low Sensitivity-- turn on in heavy rainfall.
(You would want your car's wipers on high)
Dark Detect-- if this enabled, the output will also turn on when the ambient light drops below about 2000 lux. This feature may be used to retract a sun-shade awning when it is dark.
X 0 X X Output off when rain stops.
1 Output Monostable Extended by 15 minutes
0 X X X No Dark-Detect - Normal operation
1 Dark Detect
Use this mode to control equipment that should be controlled,
Mode 2-- Condensation Sensor
Rain Gage detects condensation or frost formation on the surface.
Switch
7 6 5 4 3 2 1
Behavior
0 1 0 0 0 0 0 Very Sensitive- first sign of condensation
0 1 Sensitive
1 0 Medium Low
1 1 Low
The rain sensor senses condensation by detecting a shift from the
"clear" condition. The relay closes when the condensation occurs, and opens when the condensation goes away. The rain sensor is set to very gradually adapt the clear condition, so that very gradual build up of dirt or other contaminants do not cause a false trip.
Condensation sensing mode disables the heater and micro-power mode.
Rain Gage Model RG-11 Instructions
PN 55-005-100 rev 6
Mode 3-- Wiper Control
Rain sensing wiper control from off through intermittent and steady slow speeds.
Switch
7 6 5 4 3 2 1
Behavior
0 1 1 X 0 0 0 Normal Wiper Control
0 0 1 Wipe More
0 1 0 Wipe a Lot More
0 1 1 Wipe a Whole Lot More
1 0 0 Wipe Less
1 0 1 Wipe a Lot Less
1 1 0 Wipe a Whole Lot Less
1 1 1 Wipe hardly at all
0 X X X Normal Slow Cycle Time (1.2 to 3 sec.)
1 Long Slow Cycle Time (3 – 8 sec.)
The RG-11 may be used to control a wiper system. The output relay turns on when the slow motor winding should be engaged.
This will typically be used to drive an external relay, which will in turn drive the wiper motor windings. This may be used for the wipers for a boat, ship, locomotive, observation window, or many other applications. The RG-11 does not care what the wipers are wiping.
WARNING: The relay contacts of the RG-11 can control only a 1A load, and wiper systems generally require many times that current.
The RG-11 MUST be used with a suitable external relay in wiper control applications.
The nominal wiper control is set so that it properly controls the wipers of a passenger car. It is optimized for wiper systems that require between 1.2 and 3 seconds to make a single complete actuation of the wipers. A long cycle time is provide (Switch 4 on) for systems with a wiper actuation cycle time between 3 and 8 seconds. In all cases, the RG-11 provides a pulse to initiate the wiper actuation. Most wiper system will include some sort of cam feedback mechanism that causes the wipers to keep running until they reach a home position.
Mount the RG-11 so that it generally gets the same rainfall as the surface to be wiped. Usually, this means about a 45 degree angle.
The RG-11 does not need to be within the actual field of view of the window.
Adjust the sensitivity control DIP switches (3, 2, and 1) to set the system to wipe more or less, depending on the needs of the installation.
Mode 4: Irrigation Control
Rain Gage output on means inhibit watering.
Switch
7 6 5 4 3 2 1
Behavior
1 0 X X 0 0 0 Typical Water Control. Inhibit watering for up to 5 days.
0 0 1 Water More
0 1 0 Water a lot more
1 0 0 Water Less
1 0 1 Water a lot less
0 X X X Inhibit irrigation during a storm
1 Allow irrigation during a storm
0 X X X X Inhibit irrigation during freeze
1 Allow irrigation during freeze suitable supply.)
The nominal irrigation profile is set so that the ground receives an inch of water per week. It will inhibit watering upon the accumulation of 0.2 inches of water, and re-enable the system after that water has evaporated. This can be a short as less than a day, or as long as six days, depending on rainfall. Additional
DIP switch settings are provided for allowing more or less watering, as shown in the table below.
Nominally (Switch 4 off), the RG-11 will inhibit watering during a storm, even if not much water has accumulated. The reasoning is that if it is raining hard now, the rainfall is likely to deliver enough accumulation to justify inhibiting at least the current cycle of watering. This prevents the “it's pouring, but my sprinklers are still running” objection from the customer, and the accompanying excessive runoff and muddy ground. The feature may be defeated by turning switch 4 on.
Normally, the RG-11 will inhibit irrigation if the temperature drops below freezing, or nominally about 34 degrees. If SW 5 is on, the
RG-11 will allow irrigation below 34 degrees. Micro-power mode is disabled in irrigation control.
The RG-11 may be set to provide precise control of an irrigation system. Typically, the installation will connect to the COM and NC relay contacts to interrupt the valves when watering should be inhibited. Note that the RG-11 also requires 24 VAC (or other
Rain Gage Model RG-11 Instructions
PN 55-005-100 rev 6
Mode 6-- Drop Detector
Switch
7 6 5 4 3 2 1
Behavior
The RG-11 may also provide drop detection. Use this if you want to do your own, external data interpretation. The output will pulse once with each detected drop. Normally, it will produce longer pulses (in multiples of 200 mS) for larger drops. If set to multiple pulses per drop (SW 3 ON), each detected drop will generate one or more 100 mS pulses, depending on drop size.
1 1 0 0 X 0 0 Normal drop threshold
0 1 Sensitive Drop threshold. Expect rare false trips.
1 0 Hi drop threshold. Trip only with large drops.
0 X X One pulse per drop, longer pulses for bigger drops
In sensitive mode, the threshold for drop detection is lowered to below the normal level. This makes the system more sensitive, but raises the possibility of false detections. It is up to the system designer to determine the proper tradeoff. Similarly, the Hi drop threshold will provide an output only for large drops, making false detections unlikely, for installations were a false detection is especially objectionable.
1 Multiple pulses per larger drop
SAFETY, LIMITS OF RAIN GAGE LIABILITY, AND WARANTY
Only the rain sensor is covered-- absolutely no consequential damages
It is the responsibility of the systems integrator and purchaser of the Rain replaced under warranty. Tiny cracks or crazing within the lens is also
Gage to insure a safe installation. Any mechanical system, including one that incorporates a Rain Gage, requires appropriate safety interlocks.
Hydreon Corporation (Hydreon) warrants only the actual cost of the sensor, and only that it is free from defects in workmanship. considered cosmetic, and units so affected will be replaced only if they are deemed by Hydreon corporation to be considered to be of a functional nature.
The Rain Gage is warranted to be free from defects for a period of one year from date of purchase. Under no circumstances will Hydreon be liable for any consequential damages due to failure or any other mishap involving a Rain Gage. Hydreon's liability in the event of a failure, or inability to sense a condition, is limited to the actual cost of the particular sensor. Explicitly, if other objects are destroyed due to water damage, or if any object is destroyed because of a false indication of water, Hydreon is in no way whatsoever liable for anything other than the cost of the Rain
Gage, and then only if the Rain Gage is shown to have some defect in materials or workmanship. Limitations and imperfections of the Rain Gage do not constitute a defect. Further, if some valuable data is not gathered because an erroneous indication of any sort due to the Rain Gage,
Hydreon is liable only for the cost of the Rain Gage.
It is the responsibility of the system designer and purchasers of the Rain
Gage to insure that a failure of the Rain Gage will not cause consequential damages. If a failure in Rain Gage would cause disaster, we recommend against deployment of the Rain Gage, or against the system in which the
Rain Gage is deployed. If a failure of a Rain Gage would cause great expense, Hydreon recommends redundant Rain Gages, and even in that case do not assume any liability for consequential damages. It is the responsibility of the system designer and purchasers of the Rain Gage to be aware of performance limitations of the device. If a Rain Gage fails for any reason Hydreon will not be responsible for the labor of servicing and or installing and/or removing the Rain Gage. Labor is NOT COVERED.
Hydreon recommends that the system designer perform a Failure-Mode
Effects Analysis that includes the possibility of Rain Gage failure. If a potential purchaser of the Rain Gage does not agree with these terms, we ask that the potential purchaser not buy the Rain Gage. Deployment of the
Rain Gage implies understanding and agreeing to these limits of liability.
Apply engineering judgment: Hydreon does not claim the RG-11 is a perfect rain sensor. It is what it is, and senses what it senses.
CASE and COSMETIC POLICY
Some amount of yellowing or discoloration of the case is considered normal cosmetic aging of the device, and sensors so affect will not be
Rain Gage Model RG-11 Instructions
PN 55-005-100 rev 6