Boca Flasher NICHE-HV Installation Manual
Boca Flasher NICHE-HV
This is a versatile LED light strip, well suited for coves or task areas where space is constrained. It features a very small profile and is suitable for both dry and wet locations. The Boca CleanDim technology ensures even dimming from 0 to 100%.
Boca Flasher NICHE-HV can be fabricated with a range of color temperature choices, affording a multitude of options. The housing is clear anodized aluminum with a durable finish making it temperature and abrasion resistant.
It is easy to install, with included mounting brackets and job-specific drawings. Simply install the clips into the substrate, push the fixture into the clips, and connect the fixture to power. For rigid connections, connect the male and female end caps and twist until secure.
Advertisement
Advertisement
Installation Manual
NICHE-HV
WARNING: DO NOT LIFT FIXTURE BY CABLES.
This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/ or putting undue pressure on the cable connections will not be covered under the warranty!
DO NOT ATTEMPT TO INSTALL OR USE THE NICHE-HV FIXTURE WITHOUT READING THE INSTALLATION
INSTRUCTIONS AND SAFETY LABELS COMPLETELY.
Failure to adhere to these instructions could result in serious injury or property damage.
DO NOT MODIFY, ALTER OR ATTEMPT TO SERVICE THE NICHE-HV. DOING SO WILL VOID THE WARRANTY.
Installation Instructions
NICHE-HV
Solid Color line Voltage Dimmable leD light Strips
Introduction:
The Boca Niche-HV is a very small profile line voltage fixture well suited to coves or task areas where space and energy consumption are constrained. Boca’s CleanDim® technology ensures even dimming from 0-100%. The Boca Flasher Niche-HV can be fabricated with a range of color temperature choices, affording a multitude of options. The housing is clear anodized aluminum with a durable finish making it temperature and abrasion resistant.
Maintenance:
CleanIng To clean surface use a soft damp cloth.
Storage Store in a dry, well-ventilated area when product is not in use.
Keep the electrical cord away from heated surfaces when in use or not in use.
If cord shows signs of damage do not use, return product to manufacturer.
Electrical Specifications:
1. Input Voltage: 90-120VAC
2. Total linear ft per 20A breaker: 165ft (8 wplf), 330ft (4 wplf)
3. Total linear ft per 15A breaker: 125ft (8 wplf), 250ft (4 wplf)
4. Input Current: 95mA RMS per linear ft (8 wplf),
48mA RMS per linear foot (4 wplf)
IP65
DAMP LISTING
IP68
WET LISTING
Model Dependent
Max temp: 55C
Min. temp: -40C
Fixtures must be installed by a qualified and licensed electrician in accordance with all national, state and local electrical codes and regulations.
If any part of this manual does not meet the necessary codes and regulations, contact the factory for more information before attempting to install.
Turn Power Off At Circuit Breaker Before Beginning Installation!
INCLUDED IN ThIS PACkAGE:
1
NICHE-HV Fixtures
(In lengths shown on job specific drawings)
2
Mounting Brackets
(2 brackets per fixture)
3
Job Specific Drawings
▶
Rotate Fixture to see label on side.
NICHE-HV
BF-01
BF-01
Labels on fixtures correspond with nomenclatures on drawings.
Page 2 oF 5
Installation Instructions
NICHE-HV
1. INSTALL CLIPS INTO SUBSTRATE
1a 1b
Screw Information:
1. Screws not provided by Boca Flasher.
2. Boca Flasher recommends wide washer flat head Philips #6 screw.
(not to exceed .1380” in diameter).
3. Length of screw will vary depending on mounting surface.
*For vertical installation, please contact the factory for specific mounting instructions.
2. INSTALL FIXTURES INTO CLIPS
2a
Push Fixture down with slightly firm pressure.
2b
Clip will securely snap into place. snap!
3. CONNECT FIXTURE TO POWER
INDOOR / DRY INSTALLATION ONLY
▶
*Green ground can be removed or attached to J-Box.
Page 3 oF 5
Installation Instructions
NICHE-HV
4.
CONNECT FIXTURES TO POWER wIth DI
MM
Ing SySteM
INDOOR / DRY
INSTALLATION ONLY
*Green ground can be removed or attached to J-Box.
5.
5a secure.
1
Connect Male and Female end caps in then twist until 5b
2
Page 4 oF 5
Installation Instructions
NICHE-HV
IMPORTANT SAFETY REMINDERS:
1. DANGER:
To reduce the risk of electric shock, always unplug the NICHE-HV from electrical outlet before cleaning. Cut breaker if outlet is not available.
2. To reduce the risk of burns, fire, electric shock or injury to persons:
• Use the NICHE-HV only for its intended use as described in these instructions.
• Do not use attachments not recommended by Boca Flasher.
• Never operate the NICHE-HV if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. If the seal appears to be damaged/broken/torn return the NICHE-HV to a service center for examination or repair.
• Keep cord away from heated surfaces.
• Never drop or insert any object into any opening.
• Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
3. WARNING:
Do not attempt to install or use the NICHE-HV without reading the installation instructions and safety labels. Failure to adhere to these instructions could result in serious injury or property damage.
4. Do not modify, alter or attempt to service the NICHE-HV:
Doing so will void the warranty.
5. Do not use sharp tools near or on the fixture lens:
Doing so will result in property damage and void the warranty.
Boca Flasher, Inc.
508 S. Military trail n Deerfield Beach, Florida n 33442 USa
Phone: 561-989-5338 n Fax: 561-982-8323 www.bocaflasher.com
We are constantly improving our fixtures and reserve the right to change options and specifications. Additional information & details at www.bocaflasher.com. For specific requirements, contact your Boca Flasher sales representative. Boca Flasher, Inc. 508
S. Military Trail, Deerfield Beach, Florida 33442 USA Phone: 561.989.5338 Fax: 561.982.8323 © 2017 Boca Flasher, Inc. All rights reserved. All names and trademarks are property of their respective owners. REV 07-2017
IP65
DAMP LISTING
IP68
WET LISTING