Advertisement
Advertisement
RevoLine VariEco NHK
Assembly instructions
General
Application: Tubular drive for small rolling doors, roller shutters and textile sun protection
Limit stop: Mechanical
Special feature: Emergency manual operation, noiseless soft brake (up to 20 Nm)
Shaft size: Type M from Ø 50 mm, type L from Ø 63 mm
Standard scope of delivery
• 2 m connecting cable, assembly instructions
Accessories
• Adapter sets, motor bearing, control units
Safety instructions
&$87,21
Adjustment of end positions
UP
DOWN/
CLOSE
DOWN/
CLOSE
UP
DOWN/
CLOSE
UP
UP
UP
UP
Assembly
•
•
•
•
•
•
•
•
•
•
Only connect the drive with the power turned off.
Only insert the drive's plug with the power turned off.
The drive is only capable of operation while installed.
Never adjust the end position to a mechanical stop.
The length of the winding shaft is determined for each specific installation depending on the drive head and motor bearing used at the installation site.
Do not drill holes in the area of the tubular drive.
•
•
Installation in profile tubes
Push drive with the suitable drive adapter and limit switch crown into the profile tube. Install the shaft with drive and counterpart support so that the limit switch setting mechanism is accessible.
•
•
Secure the counterpart support to prevent axial movement
(screw on the idler or rivet it on).
Connect the drive to the the core colours.
elero assembly cable, matching up
•
Allow the drive to run in DOWN/CLOSED direction until the limit switch cuts out.
• Attach the blind to the shaft.
Installation in round tubes
On the round tube, cut a slot in the end of the tube on the drive side.
Push the drive in so that the lug of the drive engages in the slot.
Screw in the drive adapter or rivet it.
Allow the drive to run in DOWN/CLOSED direction until the limit switch cuts out.
Attach the blind to the shaft.
DOWN/
CLOSE
Adjusting key: item number 13 109.6401
DOWN/
CLOSE
NOTE: For activation of the limit switch setting screws, use the setting tool or Phillips/hexagon socket tool. Never use an electric screwdriver!
Important: The limit switch setting screws for the upper end position and lower end position are assigned depending on the parallelism of the rotating limit switch crown with the running direction arrow.
Upper end position
1.
2.
3.
4.
Allow the drive (without blind) to run fully in DOWN/CLOSED direction.
Attach the rolled-down blind to the shaft.
Push the [ OPEN ▲ ] button and keep this held down.
Using the setting tool, turn the limit switch setting screw in positive or negative direction until you reach your desired upper end position.
Lower end position
5.
6.
] button and keep this held down.
Using the adjusting key, turn the DOWN limit switch setting screw in positive or negative direction until you reach your desired lower end position.
Allow the drive to run into the relevant end position until the limit switch cuts out. The electric cut-out must take place before the blind has reached the end position of its mechanical travel path.
If the blind is constantly operated as far as its end position, there is a risk of damage to the drive and/or blind or even a danger it will be destroyed.
Take into account any possible changes to the length of the blind due to temperature fluctuations or weather influences. Allow for a safety margin.
UP
DOWN/
CLOSE
DOWN/
CLOSE
UP
DOWN/
CLOSE
138164001_EN_0519
boiter de de volet
PE
L oder -taster
M
1~
M
1~
1 0 2
1 0 2
RevoLine VariEco NHK
Assembly instructions
Electrical connection
Note:
Due to feedback voltage from the installed capacitor, never connect several drives in parallel.
The motor controls in UP/DOWN direction must be interlocked with one another. A reversing delay of at least 0.5 sec. must be ensured. junction box
M
1~
1 0 2
Emergency crank handle
Note:
Tubular drive versions with the additional code NHK are fitted with an emergency unlocking device.
The emergency unlocking device ensures that the blind can be opened or closed in case of an emergency. Examples of emergencies might be blackouts or a defect to the tubular drive.
The emergency unlocking device is not intended to be used on regular basis as otherwise the tubular drive may become damaged.
•
•
•
•
•
Emergency release of the tubular drive via the manual
CAUTION
Hands, loose items of clothing or long hair may become entrapped and crushed.
Disconnect the tubular drive from the mains power prior to emergency unlocking (switch should not be operated).
Attach the manual override/emergency crank handle to the tubular drive.
Open or close the blind slowly by turning the manual override/ emergency crank handle.
Bearing surface has to be lubricated whith PD1.
EU Conformity
Notes on troubleshooting
•
•
•
Fault
The drive does not switch off in the end position via the limit switches
Drive does not react
Drive does not react
•
•
Cause
Limit switch crown is not being driven
91,5
74
Incorrect connection
1 0 2
•
•
Remedy
Readjust installation and limit switches via the limit switch adjustment screws
Set limit switch
LK
•
60
Readjust connection
Drehmoment nach Arbeitsanweisung./
Torque according to work instruction.
d
233941201
1
Manufacturer's address
elero GmbH
101013621
2
Service
PE
L
1
1
1
Excelstückliste wall anchors
13 106.3501
Menge
1
Mengeneinheit
STK
STK
STK
STK
Dokumentnummer
233941201
7 mm 6-edge with awning loop
23 771.0002
231620002 wall anchors
138200001
Endschalter kpl. 6F
Sicherheitshinweis front element
Material
1
1
STK
STK
138164001
138066003
Einstellanleitung
Aufkleber Typenschild -
1 MM Transferfolie 110x450 lfm.TMX Super Pr.
The technical data specified is subject to tolerance factors
STK
138037103
133092102 Motorrohr 595 Präz. St-Rohr 45 x 1,5 DIN 2393 1
All illustrations are non-binding.
Senkschraube EJOT Altracs Plus 4x10
Torx 20
St verzinkt
2 STK 101013621 St verzinkt Schraube WN 1552 - DG35x7
C
Kommentar
Spherical bearing for coupling funnel 23 772.0002 articulated crank with spherical bearing a nd
7 mm
hexagonal 23 764.0002
Spherical bearing with awning eyelet 23 731.0002
EJOT Nr.:441 0383
801
D
Drehmoment nach Arbeitsanweisung./
Torque according to work instruction.
d
677
629
Schrauben mit 4,3 u 0,3 Nm anziehen./
Tighten the screws whith 4,3 u 0,3 Nm.
d
ø 12.5 x 18.5 tief
133092102
1 with ø 12 bolts
101014701
4 a
Connecting cable pluggable
138066003
1
231620002
1
63
+7
-3
26
30°
100
90
O
60 b
Link für Typenschildabstand
Rear cable outlet
Edges broken
Diese Maße werden besonders geprüft
This dimensions are particularly examined
-
-
-
-
d c b a
Index:
-
-
-
-
-
Drehmomentangaben hinzu gekommen.
MiniPlug entfernt
Typenschild geä.
Rohrindex erhöht, Schraube war 101010907.
Kurzbeschreibung / Short Comment:
Allgemeintoleranzen
General Tolerances:
DIN ISO 2768-1 m-E
DIN ISO 2768-2 K-E
-
-
-
-
-
30.10.2018
06.12.17
24.10.17
20.06.2017
Datum / Date:
-
-
-
-
-
FLD
HEC/WAT
HEC/WAT
FLD
Name:
Datum / Date: Name:
A-EW 31.07.2014
fleischerd geprüft proofed:
Werkzeug-Nr
Tool-Number:
-
CAD-Nr / CAD-No: 348430001.asm
elero GmbH
Antriebstechnik
Linsenhofer Str. 65, D-72660 Beuren
Fon: (0049) 7025 / 13-01
Fax: (0049) 7025 / 13-390
Maßstab / Scale:
Werkstoff / Material:
1:2
Gewicht / weight:
Solid Edge
2510 g
-
Benennung / Title:
VVaarriiEEccoo MM3300 NNHHKK
Verwendung , Kennzeichnung / Used in, Spezification:
Zeichnungsnummer / Drawingnumber:
334488443300000011
Blatt / Sheet: Blattanzahl / Number of sheets: -
33 M6
E= 26
2 | EN
Baugröße Typ
M10-17 NHK 120V
M20 NHK/ M16-17 NHK 120V
M30 NHK/ M36-12 NHK 120V
M50 NHK
RolTopD+ M6 NHK
RolTopD+ M10 NHK
RolTopD+ M20 NHK
RolTopD+ M30 NHK
Stator FE D
604
527
587
577
644
634
664
507
C
621
544
604
594
661
651
681
524
26
26
26
26
26
26
26
E
26
Motorrohr
565
488
548
538
605
595
625
468
RevoLine VariEco NHK
Assembly instructions
Technical data and dimensions:
VariEco M NHK / VariEco L NHK
Size / Type
Rated voltage [V]
Noiseless soft brake •
VariEco
M20 NHK
1 ~ 230
Rated torque [Nm]
Rated speed (1/min) 14
Rated current [A] 0,90
Rated power consumption [W]
Shaft diameter
20
200
50
VariEco
M30 NHK
1 ~ 230
-
30
14
0,90
200
VariEco
M40 NHK
1 ~ 230
-
40
14
1,05
242
VariEco
M50 NHK
1 ~ 230
-
50
14
1,30
300
VariEco
L40 NHK
1 ~ 230
-
40
14
1,45
333
VariEco
L60 NHK
1 ~ 230
-
60
14
1,55
356
VariEco
L80 NHK
1 ~ 230
-
80
14
1,80
415
VariEco
L100 NHK
1 ~ 230
-
100
11
1,70
390
VariEco
L120 NHK
1 ~ 230
-
120
11
2,00
460
Protection class (IP) 44
Limit switch range
(revolutions)
29
Operating time
(min S2)
Length C [mm]
4
661
Length D [mm]
Length E [mm]
Ø F [mm]
Weight [kg]
Ambient operating temperature [°C]
644
27
45
2,2
-20 to 60
•
Protection class I
Plug-in connection cable [m]
Item number
2.0
50
44
29
4
651
634
27
45
2,5
-20 to 60
•
2.0
50
44
29
5
682
665
27
45
2,7
-20 to 60
•
2.0
50
44
29
4
682
665
27
45
3,1
-20 to 60
•
2.0
63
44
29
4
730
713
27
58
5,76
-20 to 60
•
2.0
63
44
29
4
730
713
27
58
576
-20 to 60
•
2.0
63
44
29
4
760
743
27
58
6,2
-20 to 60
•
2.0
63
44
29
4
760
743
27
58
6,2
-20 to 60
•
2,0
63
44
29
4
760
743
27
58
6,2
-20 to 60
•
2,0
34 833.0001 34 843.0001 34 853.0001 34 863.0001 36 925.0002 36 935.0002 36 945.0001 36 955.0001 36 965.0001 elero GmbH
Antriebstechnik
Maybachstr. 30
73278 Schlierbach [email protected]
www.elero.com
Subject to technical changes EN | 3

Public link updated
The public link to your chat has been updated.
Advertisement