Elero VariEco+ -868 Instruction
elero VariEco+ -868 is a roller shutter and awning drive that can be controlled via radio signal. It is suitable for use in both indoor and outdoor areas - do not install in areas at risk of explosion though. This drive can be used for motorized opening and closing of roller shutters and awnings. Upon installation, a limit switch adjustment is required to set the upper and lower end positions of the travel range. Also, make sure to keep people and children away from the system while it's in operation and disconnect the drive from the power supply when working on the system.
Advertisement
Advertisement
VariEco+-868 roller shutter/awning drive
Keep these instructions in a safe place!
After installation of the tubular drive attach these instructions to the cable fot the electrician.
Device function:
When the drive is shipped from the factory, the quick limit
position adjustment is active.
Only use this function for the first adjustment.
The limit switches do not switch over during the quick limit position adjustment process. Run to the limit positions. Carry out the re-adjustment via the limit switch adjusting screws after deactivation of the quick limit switch adjustment.
Further limit position changes are only possible via the limit switch adjusting screw.
Warning!
Important safety instructions!
Observe the following instructions.
Risk of injury due to electrocution.
The connections to the 230 V mains must be made by authorised specialist personnel.
Check the system (roller shutters, awnings) regularly for wear or damage.
The regulations of the local energy supply company as well as the regulations for wet and damp rooms
according to VDE 0100 must be followed when making the connections.
Only use unmodified original eler o electrical parts.
Keep people away from the system until it is stationary.
When working on the system (servicing, cleaning
windows etc.), always disconnect it from the mains supply.
Intended use
• Please ensure that the radio installations are not operated in areas of increased possible interference.
(e.g. hospitals, airports ...).
• The radio control is only permitted for devices and units with which a functional interference in hand-held/wall-mounted transmitters or receivers poses no danger for persons, animals or materials or where this risk is covered by other safety appliances.
• The operator has no protection whatsoever from interferences by other radio emitters and local terminals (e.g. also from radio installations), that are normally used on the same frequency range.
• Only use radio receivers with equipment and units approved by the manufacturer.
Optimal use of the radio signal
• Do not bend the antenna.
• Do not shorten or extend the antenna.
• If reception is poor, adjust the antenna.
• Install the antenna so that it is as exposed as possible.
• The minimum distance between two radio drives must be at least 15 cm.
Check the following before installation:
• Only turn the limit switch ring slightly before and during
assembly. (It interferes with the result of the end position adjustment)
• The drive is only capable of operation as installed.
• Only perform connecting work with the power turned off.
• Do not connect motor plug with mains on.
• The hanging must be attached to the winding shaft.
• Do not drill in the area of the tubular motor!
• The profile tube must have sufficient clearance from the motor tube.
Installation
Observe the following installation instructions!
Warning!
– The drive must be fixed in such a way that it does not endanger personnel.
– Before installing the drive, all lines and equipment, which are not required for operation, must be removed from the site.
– During installation, during operation and when work is carried out on the system, the option to separate all three poles from the mains must always exist (Hirschmann connector and
Hirschmann coupling or a two-pole switch with minimum 3 mm contact gap or all-pole main switch).
– If the drive is controlled by a switch with OFF
pre-setting (dead man’s button), the momentary contact switch must be fitted at a height of more than 1.50 m and separated from the moving parts.
The travel range of the systems must always be visible during operation.
– Moving parts in a drive, which are below 2.5 m, must be protected.
– Set torque and set operating time must be
adapted to the requirements of the product which is driven.
– Please note the technical data on the type plate.
– Please note that with this drive (type M and
L tubular motors) the smallest internal tube
diameter corresponds with 46 mm and 56 mm.
– The drive must be installed so that it cannot get wet.
– Do not install drives in surroundings which are at risk of explosion or in mobile appliances
(e.g. motor vehicles).
– Keep children away from the (remote) control unit.
Remove of the motor cable plug
Risk of injury due to
Warning!
When the motor cable plug is removed the supply line must have no voltage.
Delivery condition Remove plug
2
→
1
→
Insert plug
→
3
Remove the motor cable plug
Switch off voltage supply.
1. Press locking mechanism on the plug towards the cable using a screwdriver.
2. Pull out the plug.
Insert the motor cable plug
3. Switch off voltage supply. Insert plug until locking mechanism
engages.
138188206_EN_1112
2
Mounting and initial operation
Shaft assembly
Installation in profile tubes
①
On round tubes, cut a slot in the end of the tubes on the drive side (width 4 mm,
2 length 6 mm)!
②
Push the drive
(do not knock in) so that the drive lug engages in the slot.
1
3
③
Screw on or rivet on the coupling
(adaptor)!
4
④
Attach the hangings to the shaft!
Run in the DOWN direction if it is necessary to install the hangings on the winding shaft.
Secure the abutment against axial shifting by riveting or bolting the cross member.
Commissioning
Note: Before you put the drive into the radio mode, you must set the end position.
Assembly cable connection
(only permissible for commissioning or setting procedures)
1.
Mains
3
2
1
3
2
1
Blue (neutral wire)
Black (2)
Brown (3)
Green-yellow
(1)
Explanation of ProLine buttons
Hand-held/wall transmitter
Radio connection (transmitter operation) elero
UP button
STOP button
DOWN
button
Auto
UP button
STOP button
DOWN
button
Back of wall transmitter
LR03 (AAA)
Programming button P 2. Switch on mains.
Programming button P
(Back of unit)
3
2
1
3
2
1
Mains
Blue (neutral wire)
Black (2)
Brown (3)
Green-yellow
(1) elero elero
Mounting and initial operation
Delivery status/factory setting
Quick limit switch adjustment
position „On“
+
+
-
-
The quick limit switch adjustment is activated at the factory.
Releasing screw is in the
„On“ position.
The arrow of the releasing screw points in the direction of the crown adaptor.
Limit switches are not active in the quick limit switch adjustment.
Note: The maximum limit switch range is 35 revolutions of the shaft.
Use the adjusting tool for carrying out the adjustment.
Only at commissioning
Quick limit switch adjustment
1. Attach the hangings to the shaft.
Run in the DOWN direction if it is necessary to move the
winding shaft.
2. Use the motor cable to move the hangings in the UP direction until you reach the desired limit position.
Adjusting tool
Adjusting tool
13 116.3801
Quick limit switch adjustment
position ”Off“
+
+
-
-
Note: The limit switches will only work after the motor has been installed in the shaft.
3. Turn the releasing screw to the „Off“ position.
The arrow of the releasing screw points in the direction of the cable.
Use an adjusting tool to do so.
4. Both limit positions are now roughly pre-set.
The fine adjustment must be carried out using the individual adjusting screws.
3
Adjustment of the end positions
Setting of the upper end position
(Fine adjustment or end position changes)
1. Allow the drive to run fully in the „Down“ direction.
2. Attach the roller shutter to the shaft.
3. Press the UP button on the assembly cable and keep it
depressed .
Limit switch
adjustment screws
+
+ -
-
Adjusting tool
Setting the lower end position
(Fine adjustment or end position changes)
1. Press the DOWN button on the assembly cable and keep it depressed .
+
+ -
-
Limit switch
adjustment screws
Adjusting tool
Directional arrow
Directional arrow
4. Turn the adjusting tool of the UP limit switch adjustment screw in the + or – direction until the end position is reached.
One turn of the limit switch adjustment screw represents approx. 60° of turning of the winding shaft.
Checking the end positions
Allow the drive to run alternately in both directions until the limit switch switches off.
2. Turn the adjusting tool of the DOWN limit switch adjustment screw in the + or – direction until the final end position is
reached.
One turn of the limit switch adjustment screw represents approx. 60° of turning of the winding shaft.
The directional arrows show the corresponding travel direction of the limit switch screws (4 mm Allen screws).
minus (–) = shorter travel plus (+) = longer travel
4
Programming the transmitter/
Programming further transmitters
Programming the transmitter
Condition: The drive is in radio mode.
The end positions must have been programmed.
If the end positions have not been programmed,
remove the blind from the shaft.
1. Switch off/on mains.
When the mains has been switched off for a short time, the drive is ready to be programmed for 5 minutes.
e ero
2. Press programming switch P on your transmitter.
The drive runs up and down for 2 minutes.
Programming procedure for other transmitters
Programming procedure possible for max. 16 transmitters.
In order to program further transmitters, start with the new transmitter at 1
or
1. Switch off/on mains
Auto
+ elero min. 3 sec.
Programmed transmitter
2. Press simultaneously:
UP and DOWN buttons and programming button P on the
programmed transmitter for min. 3 sec.
The drive runs up and down for 2 minutes.
Auto e ero
STOP
STOP
3. Press the UP button immediately after the start of upward
travel.
elero
Auto
New transmitter
STOP
STOP
3. Press the UP button immediately after the start of upward
travel.
Auto e ero
STOP
STOP
4. Press the DOWN button immediately after the start of
downward travel.
The drive will stop.
The transmitter is now programmed.
Auto elero
STOP
New transmitter
STOP
4. Press the DOWN button immediately after the start of
downward travel.
The drive will stop.
The transmitter is now programmed.
Stopping the radio programming mode
→ see transmitter instructions
Deletion of individual transmitters
→ see instructions for the control unit
Deletion of all transmitters
→ see instructions for the control unit
5
6
Notes on troubleshooting
Troubleshooting
Fault
• Radio programming mode
does not start
• Radio transmitter not in
programming mode
• Drive runs only in one direction
• The drive does not switch off
via the limit switch
• Drive does not react
• Drive is no longer reacting
• Faulty connection
• Drive not connected to mains
• Time frame already expired (5 min)
• Thermostat has triggered
• Radio transmitter has no battery
• UP/DOWN button pressed too late.
Note time frame (1 sec.)
• Sender ist bereits eingelernt
• Faulty connection
• Limit switch ring is not being driven
• Limit switch is not adjusted
• Wrong connection
• Thermostat has triggered
Remedy
• Check connection
• Check mains voltage
• Interrupt mains voltage briefly
• Allow drive to cool down
• Check transmitter (LED must be illuminated)
• Restart radio programming mode
• Push STOP button
• Check connection
• Readjust installation and limit switches via
the limit switch adjusting screws
• Set limit switch
• Readjust connection
• Allow drive to cool down
EC Declaration of conformity
EC DECLARATION OF CONFORMITY
We hereby declare that the following mentioned product/s meet/s the Machinery Directive 2006/42/EC
.
Product designation:
Tubular Drive
•
VariEco+ S-867 / -868 / -915 all versions
•
VariEco+ M-867 / -868 / -915 all versions
•
VariEco M-868 / -915 all versions
•
VariEco+
•
VariEco L-868 all versions
Description: Actuator for shutters and awnings with 867 / 868 / 915 MHz receiver
The conformity of the above mentioned products with the relevant health and safety requirements is taken into account by the following directives and standards:
•
R&TTE Directive 1999/5/EC
•
Low Voltage Directive 2006/95/EC
DIN EN 60335-2-97 (VDE 0700-97):2009
•
DIN EN 14202:2004
Beuren, 30.05.2012
Ralph Trost
-CE Manager-, -Representative documentation -
7
elero GmbH
Antriebstechnik
Linsenhofer Straße 65
D-72660 Beuren
Fon: +49 7025 13-01
Fax: +49 7025 13-212 [email protected]
www.elero.com
Technical parameters subject to change