Elero VariEco+ Instruction
elero VariEco+
VariEco+ is a tubular drive designed to control roller shutters and awnings. It features quick limit switch adjustment for easy installation and limit position changes. The VariEco+ is capable of parallel switching with a cut-off relay and has a reversing delay of at least 0.5 seconds. It also includes a built-in winding thermostat and capacitor.
The VariEco+ is designed for safe operation and includes important safety features such as protection against electric shock, overload protection, and thermal overload protection. It also has an adjustable torque and operating time to suit the specific requirements of the driven product.
Advertisement
Advertisement
VariEco+ roller shutter / awning drive
Keep these instructions in a safe place!
After installation of the tubular drive attach these instructions to the cable for the electrician.
Device function:
When the drive is shipped from the factory, the quick limit
position adjustment is active.
Only use this function for the first adjustment.
The limit switches do not switch over during the quick limit position adjustment process. Run to the limit positions. Carry out the re-adjustment via the limit switch adjusting screws after deactivation of the quick limit switch adjustment.
Further limit position changes are only possible via the limit switch adjusting screw.
Warning!
Important safety instructions!
Observe the following instructions.
Risk of injury due to electrocution.
The connections to the 230 V mains must be made by authorised specialist personnel.
Check the system (roller shutters, awnings) regularly for wear or damage.
The regulations of the local energy supply company as well as the regulations for wet and damp rooms
according to VDE 0100 must be followed when making the connections.
Only use unmodified original eler o electrical parts.
Keep people away from the system until it is stationary.
When working on the system (servicing, cleaning
windows etc.), always disconnect it from the mains supply.
Check the following before installation:
• Only turn the limit switch ring slightly before and during
assembly. (It interferes with the result of the end position adjustment)
• The drive is only capable of operation as installed.
• Only perform connecting work with the power turned off.
• The hanging must be attached to the winding shaft.
• The profile tube must have sufficient clearance from the motor tube.
Remove of the motor cable plug
Risk of injury due to shock.
Warning!
When the motor cable plug is removed the supply line must have no voltage.
Delivery condition Remove plug
2
→
1
→
Insert plug
→
3
Remove the motor cable plug
Switch off voltage supply.
1. Press locking mechanism on the plug towards the cable using a screwdriver.
2. Pull out the plug.
Insert the motor cable plug
3. Switch off voltage supply. Insert plug until locking mechanism
engages.
Installation
Warning!
Observe the following installation instructions!
– The drive must be fixed in such a way that it does not endanger personnel.
– Before installing the drive, all lines and equipment, which are not required for operation, must be removed from the site.
– During installation, during operation and when work is carried out on the system, the option to separate all three poles from the mains must always exist (Hirschmann connector and
Hirschmann coupling or a two-pole switch with minimum 3 mm contact gap or all-pole main switch).
–
– If the drive is controlled by a switch with OFF
pre-setting (dead man’s button), the momentary contact switch must be fitted at a height of more than 1.50 m and separated from the moving parts.
The travel range of the systems must always be visible during operation.
– Moving parts in a drive, which are below 2.5 m, must be protected.
– Set torque and set operating time must be
adapted to the requirements of the product which is driven.
– Please note the technical data on the type plate.
– Please note that with this drive (type M and
L tubular motors) the smallest internal tube
diameter corresponds with 47 mm and 58 mm.
– The drive must be installed so that it cannot get wet.
– Do not install drives in surroundings which are at risk of explosion or in mobile appliances
(e.g. motor vehicles).
– Keep children away from the (remote) control unit.
Installation in profile tubes
Ⓐ
Push drive with relevant adapter and limit switch into the profile tube.
Protect the motor cable in order to avoid it brushing against the hangings. Avoid kinking the cable.
Ⓑ
Secure the counterpart support
to prevent axial movement,
e.g. screw or rivet on cross member.
Secure the drive axially in the motor bearing!
Ⓒ Attach the hangings to the shaft!
Run in the DOWN direction if it is necessary to install the hangings on the winding shaft.
Warning!
A
Risk of injury due to electric shock.
Do not drill in the area of the motor!
C
B
138136501_EN_0913
Connection and limit switch adjustment
Shaft assembly
Installation in profile tubes
①
On round tubes, cut a slot in the end of the tubes on the drive side (width 4 mm, length 6 mm)!
2
1
②
Push the drive
(do not knock in) so that the drive lug engages in the slot.
③
Screw on or rivet on the coupling
(adaptor)!
3
4
④
Attach the hangings to the shaft!
Run in the DOWN direction if it is necessary to install
the hangings on the winding shaft.
Secure the abutment against axial shifting by riveting or bolting the cross member.
Check the following before installation:
• The drive is only capable of operation as installed.
• It is not permitted to adjust the limit position to a mechanical stop.
• Only perform connecting work with the power turned off.
• Do not drill in the area of the tubular motor!
• Do not connect motor plug with mains on.
Connection example VariEco+ tubular motor
230 V / 50 Hz
Delivery status/factory setting
Quick limit switch adjustment
position „On“
+
+
-
-
The quick limit switch adjustment is activated at the factory.
Releasing screw is in the
„On“ position.
The arrow of the releasing screw points in the direction of the crown adaptor.
Limit switches are not active in the quick limit switch adjustment.
Note: The maximum limit switch range is 35 revolutions of the shaft.
Use the adjusting tool for carrying out the adjustment.
Adjusting tool
Adjusting tool
13 116.3801
Note: The limit switches will only work after the motor has been installed in the shaft.
Only at commissioning
Quick limit switch adjustment
1. Attach the hangings to the shaft.
Run in the DOWN direction if it is necessary to move the
winding shaft.
Winding thermostat
Capacitor
Limit switch
Motor cable plug green/ yellow
Branch box
(outside of roller shutter case)
1 0 2
Switch box
Mains 230V/50Hz
L
N
PE
Note: The motor controls in up/down direction must be locked against each other.
A reversing delay of at least 0,5 sec. must be ensured.
2. Use the motor cable to move the hangings in the UP direction until you reach the desired limit position.
Quick limit switch adjustment
position ”Off“
+
+
-
-
3. Turn the releasing screw to the „Off“ position.
The arrow of the releasing screw points in the direction of the cable.
Use an adjusting tool to do so.
4. Both limit positions are now roughly pre-set.
The fine adjustment must be carried out using the individual adjusting screws.
2 | EN
Connection and limit switch adjustment
Notes on troubleshooting
Setting of the upper limit position
(Fine adjustment or limit position changes)
Setting the lower limit position
(Fine adjustment or limit position changes)
1. Press the DOWN button on the assembly cable and run the hangings down a little bit from the upper limit position.
2. Then press the UP button on the assembly cable and hold it down.
Limit switch
adjustment screws
+
+ -
-
1. Press the DOWN button on the assembly cable and keep it depressed .
+
+ -
-
Limit switch
adjustment screws
Direction of travel arrow
3. Turn the adjusting tool of the UP limit switch adjusting screw in the + or – direction until the final limit position is reached.
One turn of the limit switch adjusting screw represents approx.
60° of turning of the winding shaft.
Direction of travel arrow
2. Turn the adjusting tool of the DOWN limit switch adjusting screw in the + or – direction until the final limit position is
reached.
One turn of the limit switch adjusting screw represents approx.
60° of turning of the winding shaft.
The directional arrows show the corresponding travel direction of the limit switch screws (4 mm Allen screws).
minus (–) = shorter travel plus (+) = longer travel
Troubleshooting
Fault
• Switching off points
are far from the limit
positions after the quick
adjustment is made
• Limit switch ring was turned before
and during installation
• Drive is retracted in the installed position
without hangings
• The drive does not switch off
via the limit switch
• Drive does not react
• Drive does not react
• Limit switch ring is not being driven
• Quick limit switch adjustment is still active
• Limit switch is not adjusted
• Wrong connection
• The thermostat has triggered
Remedy
• Adjust limit positions via the limit switch
adjusting screw
• Readjust installation and limit switches via
the limit switch adjusting screws
• Deactivate quick limit switch adjustment
• Set limit switch
• Readjust connection
• Cool drive down
EN | 3
Declaration of conformity
EC DECLARATION OF CONFORMITY
We hereby declare that the following mentioned product/s meet/s the Machinery Directive 2006/42/EC
.
Product designation:
Tubular Drive
Description:
•
VariEco+ S all versions
•
VariEco S all versions
•
VariEco+ M all versions
•
VariEco M all versions
•
VariEco+ L all versions
•
VariEco L all versions
Actuator for shutters and awnings
The conformity of the above mentioned products with the relevant health and safety requirements is taken into account by the following directives and standards:
•
EMC 2004/108/EC
•
Low Voltage Directive 2006/95/EC
DIN EN 60335-2-97 (VDE 0700-97):2009
•
DIN EN 14202:2004
Beuren, 30.05.2012
Ralph Trost
-CE Manager-, -Representative documentation -
elero GmbH
Antriebstechnik
Linsenhofer Straße 65
D-72660 Beuren
Fon: +49 7025 13-01
Fax: +49 7025 13-212 [email protected]
www.elero.com
We reserve the right to make technical changes

Download
Advertisement