International comfort products PHD348000KTP0C PHD3 Series 4 Ton 13.5 SEER R-410A Packaged Heat Pump Specification
PDF
Download
Document
Advertisement
Advertisement
PHD3 LLY SOUND TA R EN ERANT IG FR E Product Specifications ENVIR ON M 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT • Environmentally sound R−410A refrigerant • Copper tube/aluminum fin condenser and evaporator coils • Scroll compressor standard on all models • Short−cycling protection for the compressor is built into the defrost control board • Dehumidification mode (airflow reduction) on all models EASY TO INSTALL AND SERVICE • Installs easily on a rooftop or at ground level • Easy three−panel accessibility for maintenance and installation • Easily converts to down discharge applications • Combination electric heating and cooling BUILT TO LAST • High efficiency ECM indoor blower motor on all models • Pre−painted steel cabinet • Vertical condenser fan discharge • Hail guard (3/8” spacing) wire grilles standard on PHD3**000KTP models (2” spacing wire grilles on non-tin models) • Full perimeter steel base rails • High and low pressure switches provide added reliability for the compressor • All models available with optional factory installed tin−coated copper evaporator coil (These models are identified with letters TP in the 11th and 12th positions in the model number) Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org . WARRANTY* • 1 year No Hassle Replacement limited warranty for models with tin coated copper evaporator coils • 5 year parts limited warranty (including compressor and coils) − With timely registration, an additional 5 year parts limited warranty (including compressor and coils) *Applies to original purchaser/homeowner, some limitations may apply. See warranty certificate for complete details. UNIT PERFORMANCE DATA Model Number PHD324000K000C PHD324000KTP0C PHD330000K000C PHD330000KTP0C PHD336000K000C PHD336000KTP0C PHD342000K000C PHD342000KTP0C PHD348000K000C PHD348000KTP0C PHD360000K000C PHD360000KTP0C COOLING Capacity BTU/h 23,800 23,800 29,000 29,000 35,000 35,000 40,000 40,000 47,000 47,000 57,000 57,000 SEER 13.5 13.5 13.5 13.5 13.5 13.5 13.2 13.2 13.5 13.5 13.5 13.5 HEATING EER 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 Capacity BTU/h 23,400 23,400 29,000 29,000 35,000 35,000 40,000 40,000 46,500 46,500 57,000 57,000 HSPF 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 Specifications subject to change without notice. Unit Dimensions Height x Width x Depth in (mm) Operating Weight lbs (kg) 421/8x483/16x325/8 (1070x1225x829) 421/8x483/16x325/8 (1070x1225x829) 421/8x483/16x325/8 (1070x1225x829) 421/8x483/16x325/8 (1070x1225x829) 421/8x483/16x325/8 (1070x1225x829) 421/8x483/16x325/8 (1070x1225x829) 443/4x483/16x441/8 (1137x1225x1122) 443/4x483/16x441/8 (1137x1225x1122) 443/4x483/16x441/8 (1137x1225x1122) 443/4x483/16x441/8 (1137x1225x1122) 483/4x483/16x441/8 (1238x1225x1122) 483/4x483/16x441/8 (1238x1225x1122) 320 (145) 320 (145) 332 (150) 332 (150) 336 (152) 336 (152) 441 (186) 441 (186) 429 (194) 429 (194) 454 (206) 454 (206) 518 14 2201 05 2/02/11 MODEL NOMENCLATURE MODEL SERIES 1 2 3 4 5,6 7,8,9 10 11,12 13 14 15 P H D 3 36 000 K 00 0 C 1 P = Package TYPE H = Heat Pump TIER D = Standard 3 = 13 4 = 14 SEER 5 = 15 24 = 24,000 BTUH = 2 Tons 30 = 30,000 BTUH = 2.5 Tons 36 = 36,000 BTUH = 3 Tons 42 = 42,000 BTUH = 3.5 Tons 48 = 48,000 BTUH = 4 Tons NOMINAL COOLING CAPACITY 60 = 60,000 BTUH = 5 Tons NOMINAL HEATING BTUH (input) 000 = no factory heat VOLTAGE K = 208/230−1−60 00 = No options FACTORY INSTALLED OPTIONS TP = Tin Plated Evaporator Main Tubes FEATURE CODE 0 = Standard Sales Model Digit Engineering Digit AHRI* CAPACITIES COOLING CAPACITIES AND EFFICIENCIES UNIT PHD3 24 30 36 42 48 60 NOMINAL TONS 2 2-1/2 3 3-1/2 4 5 STANDARD CFM 800 1000 1200 1400 1600 1850 COOLING CAPACITIES (Btuh) 23,800 29,000 35,000 40,000 47,000 57,000 EER** 11.5 11.5 11.5 11.5 11.5 11.5 SEER† 13.5 13.5 13.5 13.2 13.5 13.5 HEAT PUMP HEATING CAPACITIES AND EFFICIENCIES UNIT PHD3 24 30 36 42 48 60 HEATING CAPACITY (Btuh) @ 47_F (8.3_C) 23,400 29,000 35,000 40,000 46,500 57,000 COP @ 47_F (8.3_C) 3.5 3.5 3.4 3.4 3.6 3.5 LEGEND dB − Sound Levels (decibels) db − Dry Bulb SEER − Seasonal Energy Efficiency Ratio wb − Wet Bulb COP − Coefficient of Performance HSPF − Heating Season Performance Factor * Air Conditioning, Heating, & Refrigeration Institute. **At “A” conditions−80°F (26.7°C) indoor db/67°F (19.4°C) indoor wb & 95°F (35°C) outdoor db. †Rated in accordance with U.S. Government DOE (Department of Energy) test procedures and/or AHRI Standards 210/240. 2 HEATING CAPACITY (Btuh) @ 17_F (-8.3_C) 10,800 15,900 20,400 22,000 26,200 31,000 COP @ 17_F (-8.3_C) 2.2 2.2 2.3 2.2 2.3 2.3 HSPF† 7.7 7.7 7.7 7.7 7.7 7.7 Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80°F (26.7°C) db, 67°F (19.4°C) wb indoor entering−air temperature and 95°F (35°C) db outdoor entering−air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 518 14 2201 05 ELECTRICAL DATA − PHD3 VOLTAGE RANGE COMPRESSOR OFM IFM MCC FLA FLA 58.3 20.0 1.2 4.1 73 22.0 1.2 4.1 26.0 1.2 6.0 112 28.0 1.2 6.0 23.5 117 34.0 1.2 7.6 27.4 134 41.2 1.2 7.6 UNIT NOMINAL V­PH­HZ MIN MAX RLA LRA PHD324 208/230­1­60 197 253 13.5 PHD330 208/230­1­60 197 253 16 PHD336 208/230­1­60 197 253 19.3 PHD342 208/230­1­60 197 253 20.9 PHD348 208/230­1­60 197 253 PHD360 208/230­1­60 197 253 79 ELECTRIC HEAT NOMIN kW FLA 208v/230v 208v/230v ­/­ ­/­ 3.8/5 18.1/20.8 5.4/7.2 25.9/30 7.5/10 36.1/41.7 ­/­ ­/­ 3.8/5 18.1/20.8 5.4/7.2 25.9/30 7.5/10 36.1/41.7 11.5/15 54.2/62.5 ­/­ ­/­ 3.8/5 18.1/20.8 5.4/7.2 25.9/30 7.5/10 36.1/41.7 11.3/15 54.2/62.5 ­/­ ­/­ 3.8/5 18.1/20.8 5.4/7.2 25.9/30 7.5/10 36.1/41.7 11.3/15 54.2/62.5 15/20 72.2/83.3 ­/­ ­/­ 3.8/5 18.1/20.8 5.4/7.2 25.9/30 7.5/10 36.1/41.7 11.3/15 54.2/62.5 15/20 72.2/83.3 ­/­ ­/­ 3.8/5 18.1/20.8 5.4/7.2 25.9/30 7.5/10 36.1/41.7 11.3/15 54.2/62.5 15/20 72.2/83.3 POWER SUPPLY MCA MOCP 208v/230v 208v/230v 22.2 30 44.8/48.2 45/50 54.6/59.7 60/60 67.3/74.3 70/80 25.3 40 47.9/51.3 50/60 57.7/62.8 60/70 70.4/77.4 80/80 93.1/103.4 100/110 31.3 45 54/57.3 60/60 63.7/68.8 70/70 76.5/83.5 80/90 99.1/109.5 100/110 33.3 50 56/59.3 60/60 65.7/70.8 70/80 78.5/85.5 80/90 101.1/111.5 110/125 123.6/137.5 125/150 38.2 50 60.8/64.2 70/70 70.6/75.7 80/80 83.3/90.3 90/100 105.9/116.3 110/125 128.4/142.3 150/150 43.1 60 65.7/69.1 70/70 75.4/80.6 80/90 88.2/95.2 90/100 110.8/121.2 125/125 133.3/147.2 150/150 LEGEND FLA = Full Load Amps LRA = Locked Rotor Amps MCA = Minimum Circuit Ampacity MOCP = Maximum Overcurrent Protection RLA = Rated Load Amps 1. In compliance with NEC (National Electrical Code) requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be Power Supply fuse. The CGA (Canadian Gas Association) units may be fuse or circuit breaker. 2. Minimum wire size is based on 60 C copper wire. If other than 60 C wire is used, or if length exceeds wire length in table, determine size from NEC. 518 14 2201 05 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 3 PHYSICAL DATA − UNIT PHD3 UNIT SIZE NOMINAL CAPACITY (ton) SHIPPING WEIGHT (lb) (kg) COMPRESSOR QUANTITY TYPE REFRIGERANT Quantity (lb) Quantity (kg) METERING DEVICE ID ORIFICE OD (in.) (mm) OUTDOOR COIL Rows... Fins/in. face area (sq. ft.) OUTDOOR FAN Nominal Airflow (CFM) Fan Diameter (in.) Fan Diameter (mm) Diameter Motor HP (RPM) INDOOR COIL Rows... Fins/in. face area (sq. ft.) INDOOR BLOWER Nominal Cooling Airflow (CFM) Size (in.) (mm) Motor (HP) HIGH-PRESSURE Cutout SWITCH (psig) Reset (Auto) LOSS-OF-CHARGE/ (Liquid Line) (psig) LOW-PRESSURE Cutout SWITCH Reset (Auto) throwaway (in.) RETURN-AIR FILTERS*{ (mm) 24 2 327 148 30 2.5 340 154 36 3 343 156 42 3.5 419 190 48 4 437 198 60 5 462 210 9.6 4.4 10.2 4.6 0.032 (2) .81 2...21 11.9 0.035 (2) .89 2...21 11.9 1 SCROLL COMPRESSOR R-410A 7.9 10.0 3.6 4.5 TXV 0.038 (Left OD Coil) 0.040 (Right OD Coil) 0.037 (2) .97/1.02 .94 2...21 2...21 11.9 13.6 2700 24 610 1/5 (810) 3...17 3.7 2700 24 610 1/5 (810) 3...17 3.7 2700 24 610 1/5 (810) 3...17 3.7 3100 26 660 1/5 (810) 3...17 4.7 3100 26 660 1/5 (810) 3...17 4.7 3100 26 660 1/5 (810) 3...17 5.7 800 10x10 254x254 1/2 1000 10x10 254x254 1/2 1200 11x10 279x254 3/4 1400 11x10 279x254 3/4 650±15 420±25 1600 11x10 279x254 1.0 1850 11x10 279x254 1.0 20x20x1 508x508x25 20x24x1 508x610x25 9.6 4.4 12.3 5.6 0.046 (2) 1.2 2...21 13.6 0.052 (2) 1.3 2...21 17.5 20±5 45±10 24x30x1 610x762x25 24x36x1 610x914x25 *Required filter sizes shown are based on the larger of the AHRI (Air conditioning, Heating and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high−capacity type. Air filter pressure drop for non−standard filters must not exceed 0.08 Iin wc. { If using accessory filter rack refer to the filter rack installation instructions for correct filter size and quantity. DRY COIL AIR DELIVERY* − HORIZONTAL AND DOWNFLOW DISCHARGE − UNIT PHD324−60 UNIT PHD324 PHD330 PHD336 PHD342 PHD348 PHD360 MOTOR SPEED Low Med-Low Medium1 Med-High High Low Med-Low Medium Med-High1 High Low Med-Low Medium1 Med-High High Low Med-Low Medium Med-High1 High Low Med-Low Medium1 Med-High High Low Med-Low Medium1 Med-High High WIRE COLOR Blue Pink Red Orange Black Blue Pink Red Orange Black Blue Pink Red Orange Black Blue Pink Red Orange Black Blue Pink Red Orange Black Blue Pink Red Orange Black CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM 0.1 754 851 941 1009 1241 741 973 1088 1140 1202 1234 1290 1354 1606 1630 1295 1345 1505 1545 1705 1402 1457 1736 2149 2344 1445 1678 1927 2131 2461 0.2 650 777 851 917 1167 638 887 1023 1064 1140 1168 1223 1290 1546 1580 1234 1282 1452 1492 1643 1351 1404 1695 2111 2306 1389 1635 1893 2088 2409 EXTERNAL STATIC PRESSURE (in wc) 0.3 0.4 0.5 0.6 0.7 538 429 ------675 591 475 ----774 684 576 479 --840 759 667 577 447 1111 1036 969 881 818 547 415 ------823 733 665 538 451 954 881 800 723 658 996 915 840 758 687 1082 1015 961 881 810 1093 1021 961 894 825 1154 1090 1027 977 894 1226 1158 1102 1046 981 1489 1430 1371 1316 1258 1517 1463 1407 1339 1277 1182 1126 1075 1016 955 1235 1194 1140 1095 1027 1413 1358 1323 1282 1234 1449 1411 1362 1313 1278 1607 1568 1518 1483 1448 1311 1263 1224 1172 1136 1367 1318 1284 1233 1197 1642 1601 1553 1512 1465 2062 2026 1980 1945 1905 2259 2203 2141 2070 1991 1341 1281 1236 1189 1139 1602 1558 1513 1474 1438 1858 1824 1791 1759 1720 2065 2013 1982 1941 1888 2339 2286 2192 2140 2062 0.8 --------731 ----563 564 732 759 828 918 1208 1210 898 974 1169 1231 1404 1080 1144 1427 1864 1902 1072 1404 1689 1860 1968 0.9 --------640 ----461 480 631 687 762 843 1140 1131 857 921 1130 1188 1360 1041 1104 1381 1793 1803 1027 1349 1640 1785 1874 * Air delivery values are without air filter and are for dry coil (See PHD3− Horizontal Wet Coil Pressure Drop Table). 1 Factory−shipped cooling speed NOTE: For horizontal applications deduct field−supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting. For downflow applications see Wet Coil Air Delivery Table for available static including wet coil, 1−in. (25 mm) filter and economizer. Shaded areas indicate speed/static combinations that are not permitted for dehumidification speed. 4 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 518 14 2201 05 HORIZONTAL WET COIL PRESSURE DROP (in wc) UNIT PHD3 24 30 36 42 48 60 500 600 0.06 700 0.07 800 0.08 0.12 900 0.09 0.15 STANDARD CFM (S.C.F.M.) 1100 1200 1300 1400 1000 0.1 0.19 0.07 0.23 0.11 0.27 0.18 0.04 0.26 0.07 1500 1600 1700 1800 1900 2000 0.15 0.14 0.21 0.17 0.1 0.22 0.17 0.28 0.23 0.31 0.36 0.35 0.1 0.11 DOWNFLOW WET COIL AIR DELIVERY (CFM) − HIGH SPEED WITH 1−IN. (25 MM) FILTER AND ECONOMIZER UNIT PHD3 36 42 48 60 0.1 1333 1612 2166 2298 0.2 1289 1569 2085 2239 EXTERNAL STATIC PRESSURE (in wc) 0.4 0.5 0.6 0.7 1214 1152 1118 1076 1481 1451 1393 1351 1919 1798 1709 1582 2110 2044 1951 1862 0.3 1256 1527 2002 2180 0.8 1035 1317 1467 1777 0.9 997 1278 1270 1697 1.0 950 1242 988 1591 HORIZONTAL FILTER PRESSURE DROP TABLE (in wc) FILTER SIZE in. (mm) 20X20X1 (508X508X25) 20X24X1 (508X610x25) 24X30X1 (610X762x25) 24X36X1 (610X914X25) 500 600 700 800 900 1000 1100 1200 1300 CFM 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 0.05 0.07 0.08 0.1 0.12 0.13 0.14 0.15 — — — — — — — — — — — — — — .09 .10 .11 .13 .14 .15 .16 — — — — — — — — — — — — 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.1 — — — — — — — — — — — — — — — 0.06 0.07 0.07 0.08 0.09 0.09 0.10 0.11 0.12 0.13 0.14 0.14 ECONOMIZER 1−IN. FILTER PRESSURE DROP (in wc) UNIT PHD3 24-36 42-60 PRESSURE DROP 0.20 0.25 MULTIPLICATION FACTORS HEATER kW RATING VOLTAGE DISTRIBUTION 200 208 230 240 240 MULTIPLICATION FACTOR 0.69 0.75 0.92 1.00 ELECTRIC HEAT PRESSURE DROP TABLE (in wc) SMALL CABINET: PHD324−36 CFM 500 5kw 0.00 7.5 kw 0.00 10 kw 0.00 15 kw * 0.00 * Does not apply to 2 ton 600 0.00 0.00 0.00 0.00 700 0.00 0.00 0.00 0.00 800 0.00 0.00 0.00 0.02 900 0.00 0.00 0.00 0.04 1000 0.00 0.00 0.02 0.06 1100 0.00 0.02 0.04 0.08 1200 0.00 0.03 0.06 0.10 1300 0.02 0.05 0.07 0.12 1400 0.04 0.07 0.09 0.14 1500 0.06 0.08 0.10 0.16 1600 0.07 0.09 0.11 0.18 ELECTRIC HEAT PRESSURE DROP TABLE (in wc) LARGE CABINET PHD342−060 CFM 5kw 7.5 kw 10 kw 15 kw 20 kw 1100 0.00 0.00 0.00 0.00 0.02 1200 0.00 0.00 0.00 0.02 0.03 1300 0.00 0.01 0.01 0.03 0.04 1400 0.01 0.02 0.02 0.04 0.05 1500 0.02 0.03 0.03 0.05 0.06 1600 0.03 0.04 0.04 0.06 0.07 1700 0.04 0.05 0.05 0.07 0.08 1800 0.05 0.06 0.06 0.08 0.09 1900 0.06 0.07 0.07 0.09 0.10 2000 0.07 0.08 0.08 0.10 0.11 2100 0.08 0.09 0.09 0.11 0.12 2200 0.09 0.10 0.10 0.12 0.13 2300 0.10 0.11 0.11 0.13 0.14 2400 0.11 0.12 0.12 0.14 0.15 2500 0.12 0.13 0.13 0.15 0.16 MINIMUM AIRFLOW FOR RELIABLE ELECTRIC HEATER OPERATION (CFM) SIZE AIRFLOW (CFM) PHD324 800 PHD330 1025 PHD336 1250 PHD342 1400 PHD348 1710 PHD360 1800 A−WEIGHTED SOUND POWER LEVEL (dBA) MODEL PHD3 24 30 36 42 48 60 518 14 2201 05 STANDARD RATING (dBA) 76 76 77 78 78 76 TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment) 125 250 500 1000 2000 4000 8000 57.0 65.5 72.0 71.0 67.0 62.0 53.0 60.5 67.5 72.0 70.0 67.0 61.0 51.5 63.0 68.0 73.0 71.0 67.0 62.0 55.0 65.0 68.5 74.5 72.5 69.5 64.5 56.5 62.0 68.5 74.0 72.5 70.0 64.0 56.0 63.0 66.5 69.5 71.0 66.0 65.0 59.0 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 5 6 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 518 14 2201 05 26.89 29.56 72 (13.9) 24.64 62 (16.7) 67 (19.4) 24.45 57 (13.9) 24.92 29.00 72 (13.9) 63* (17.2) 26.34 24.02 62 (16.7) 67 (19.4) 23.50 57 (13.9) 24.39 28.26 72 (13.9) 63* (17.2) 25.65 67 (19.4) 23.32 62 (16.7) 23.73 22.38 57 (13.9) 63* (17.2) Total EWB _F (_C) 16.36 20.43 19.53 24.10 24.45 15.54 19.21 18.39 22.63 23.50 14.67 17.94 17.21 21.00 22.38 Sens Capacity MBtuh 75 (23.9) 1.71 1.66 1.63 1.63 1.63 1.68 1.63 1.61 1.60 1.60 1.65 1.60 1.58 1.58 1.57 Total Sys KW 28.16 25.60 23.72 23.54 23.48 27.64 25.11 23.24 22.92 22.59 26.98 24.48 22.64 22.26 21.54 Total 15.83 19.87 18.97 23.54 23.48 15.04 18.67 17.85 22.02 22.59 14.19 17.42 16.69 20.45 21.54 Sens Capacity MBtuh 85 (29.4) 1.92 1.87 1.84 1.84 1.84 1.89 1.84 1.81 1.81 1.81 1.86 1.81 1.79 1.79 1.78 Total Sys KW 26.67 24.25 22.45 22.49 22.45 26.19 23.80 22.02 21.77 21.61 25.61 23.23 21.47 21.13 20.63 Total 15.26 19.27 18.37 22.49 22.45 14.53 18.10 17.28 21.32 21.61 13.68 16.87 16.14 19.85 20.63 Sens Capacity MBtuh 95 (35) 2.15 2.10 2.07 2.07 2.07 2.12 2.07 2.04 2.04 2.04 2.08 2.04 2.02 2.02 2.01 Total Sys KW 25.07 22.78 21.07 21.34 21.31 24.66 22.38 20.69 20.58 20.54 24.14 21.88 20.21 19.92 19.64 Total 14.65 18.63 17.72 21.34 21.31 13.93 17.48 16.67 20.58 20.54 13.14 16.28 15.55 19.18 19.64 Sens Capacity MBtuh 105 (40.5) 2.40 2.35 2.32 2.32 2.32 2.37 2.32 2.30 2.30 2.30 2.34 2.30 2.27 2.27 2.27 Total Sys KW CONDENSER ENTERING AIR TEMPERATURES _F (_C) Total 7.81 7.93 8.02 7.49 7.61 7.71 7.14 7.25 7.37 CFM 700 800 900 700 800 900 700 800 900 6.78 6.67 6.57 7.09 7.00 6.89 7.38 7.29 7.18 Integ Capacity MBtuh -10 (-23.3) 1.67 1.67 1.67 1.59 1.59 1.59 1.52 1.51 1.51 Total Sys KW See Legend and Notes following tables. 75 70 65 EDB _F (_C) INDOOR AIR 9.83 9.71 9.56 10.16 10.04 9.88 10.45 10.35 10.21 Total 9.04 8.93 8.80 9.35 9.24 9.10 9.62 9.52 9.39 Integ Capacity MBtuh 0 (-17.8) 1.78 1.78 1.79 1.70 1.70 1.70 1.62 1.62 1.62 Total Sys KW 12.46 12.31 12.14 12.88 12.72 12.47 13.28 13.17 13.03 Total 11.43 11.30 11.14 11.82 11.68 11.44 12.19 12.09 11.96 Integ Capacity MBtuh 10 (-12.2) PHD324 HEATING EXTENDED PERFORMANCE TABLE 1.86 1.86 1.88 1.77 1.78 1.79 1.69 1.70 1.71 Total Sys KW 15.35 15.22 15.07 15.55 15.43 15.29 15.76 15.63 15.49 Total 13.92 13.81 13.67 14.10 14.00 13.87 14.29 14.18 14.05 Integ Capacity MBtuh 20 (-6.7) 1.92 1.93 1.96 1.82 1.83 1.86 1.73 1.74 1.76 Total Sys KW 18.04 17.89 17.72 18.28 18.14 17.96 18.54 18.38 18.20 Total 15.81 15.68 15.52 16.02 15.89 15.74 16.24 16.11 15.95 Integ Capacity MBtuh 30 (-1.1) 1.95 1.98 2.01 1.85 1.87 1.91 1.76 1.78 1.81 Total Sys KW OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 21.11 20.92 20.69 21.42 21.22 20.99 21.73 21.53 21.29 Total 21.11 20.92 20.69 21.42 21.22 20.99 21.73 21.53 21.29 Integ 2.00 2.03 2.08 1.90 1.93 1.97 1.80 1.83 1.87 Total Sys KW 23.33 21.18 19.58 20.10 20.06 22.98 20.84 19.25 19.40 19.37 22.52 20.41 18.82 18.63 18.54 Total 24.76 24.53 24.22 25.15 24.90 24.59 25.52 25.30 24.98 Total 13.99 17.93 17.01 20.10 20.06 13.29 16.81 15.98 19.40 19.37 12.55 15.64 14.89 18.50 18.54 Sens 50 (10) 2.67 2.63 2.60 2.61 2.61 2.65 2.60 2.58 2.58 2.58 2.62 2.58 2.56 2.56 2.56 Total Sys KW 24.76 24.53 24.22 25.15 24.90 24.59 25.52 25.30 24.98 Integ Capacity MBtuh 115 (46.1) Capacity MBtuh 40 (4.4) Capacity MBtuh *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 900 / 0.20 800 / 0.15 700 / 0.11 CFM / BF EVAPORATOR AIR PHD324 COOLING EXTENDED PERFORMANCE TABLE 125 (51.7) 2.09 2.12 2.18 1.99 2.02 2.07 1.89 1.92 1.97 Total Sys KW 21.45 19.46 17.97 18.71 18.69 21.15 19.17 17.68 18.10 18.07 20.77 18.80 17.32 17.36 17.33 Total 28.98 28.86 28.47 29.31 29.27 28.92 29.60 29.63 29.37 Total 28.98 28.86 28.47 29.31 29.27 28.92 29.60 29.63 29.37 Integ Capacity MBtuh 60 (15.6) 13.27 17.14 16.22 18.71 18.69 12.59 16.06 15.23 18.10 18.07 11.88 14.93 14.19 17.36 17.33 Sens Capacity MBtuh 2.22 2.28 2.34 2.12 2.16 2.23 2.02 2.05 2.13 Total Sys KW 2.98 2.94 2.92 2.93 2.93 2.95 2.92 2.90 2.90 2.90 2.93 2.89 2.88 2.88 2.88 Total Sys KW 518 14 2201 05 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 7 32.74 36.13 72 (13.9) 30.03 62 (16.7) 67 (19.4) 29.95 57 (13.9) 30.27 35.47 72 (13.9) 63* (17.2) 32.09 29.25 62 (16.7) 67 (19.4) 28.78 57 (13.9) 29.64 34.57 72 (13.9) 63* (17.2) 31.27 67 (19.4) 28.39 62 (16.7) 28.86 27.44 57 (13.9) 63* (17.2) Total EWB _F (_C) 19.76 24.80 23.63 30.03 29.95 18.74 23.29 22.24 27.45 28.78 17.68 21.73 20.79 25.49 27.44 Sens Capacity MBtuh 75 (23.9) 2.11 2.09 2.07 2.07 2.07 2.08 2.05 2.04 2.04 2.04 2.04 2.02 2.00 2.00 2.00 Total Sys KW 34.40 31.17 28.80 28.81 28.75 33.78 30.58 28.24 27.91 27.67 32.97 29.83 27.53 27.09 26.40 Total 19.10 24.11 22.96 28.81 28.75 18.14 22.64 21.59 26.71 27.67 17.10 21.10 20.17 24.83 26.40 Sens Capacity MBtuh 85 (29.4) 2.34 2.31 2.29 2.30 2.29 2.30 2.28 2.26 2.26 2.26 2.26 2.24 2.22 2.22 2.22 Total Sys KW 32.60 29.54 27.27 27.55 27.50 32.02 29.00 26.76 26.55 26.49 31.32 28.33 26.13 25.75 25.31 Total 18.43 23.41 22.26 27.55 27.50 17.52 21.96 20.92 26.55 26.49 16.50 20.46 19.52 24.11 25.31 Sens Capacity MBtuh 95 (35) 2.58 2.56 2.54 2.54 2.54 2.55 2.52 2.51 2.50 2.50 2.51 2.49 2.47 2.47 2.47 Total Sys KW 30.70 27.80 25.65 26.20 26.15 30.20 27.32 25.20 25.27 25.23 29.56 26.73 24.63 24.34 24.13 Total 17.73 22.67 21.50 26.20 26.15 16.83 21.25 20.20 25.27 25.23 15.87 19.77 18.84 23.30 24.13 Sens Capacity MBtuh 105 (40.5) 2.86 2.83 2.82 2.82 2.82 2.82 2.80 2.78 2.79 2.78 2.79 2.76 2.75 2.75 2.75 Total Sys KW CONDENSER ENTERING AIR TEMPERATURES _F (_C) 7.89 8.58 8.75 8.92 8.06 8.24 8.40 7.50 7.68 7.84 875 1000 1125 875 1000 1125 875 1000 1125 7.21 7.06 6.90 7.73 7.58 7.42 8.20 8.05 Integ Total CFM Capacity MBtuh -10 (-23.3) 2.11 2.08 2.06 2.02 2.00 1.98 1.95 1.92 1.91 Total Sys KW See Legend and Notes following tables. 75 70 65 EDB _F (_C) INDOOR AIR 11.00 10.81 10.60 11.51 11.33 11.12 11.99 11.81 11.60 Total 10.12 9.95 9.76 10.59 10.42 10.23 11.04 10.87 10.67 Integ Capacity MBtuh 0 (-17.8) 2.18 2.16 2.15 2.09 2.07 2.06 2.00 1.99 1.98 Total Sys KW 14.34 14.13 13.88 14.83 14.62 14.37 15.28 15.07 14.83 Total 13.16 12.97 12.74 13.61 13.42 13.19 14.02 13.83 13.61 Integ Capacity MBtuh 10 (-12.2) PHD330 HEATING EXTENDED PERFORMANCE TABLE 2.24 2.23 2.22 2.15 2.14 2.13 2.06 2.05 2.04 Total Sys KW 17.94 17.69 17.41 18.43 18.19 17.90 19.32 18.71 18.37 Total 16.27 16.05 15.79 16.71 16.49 16.23 17.52 16.97 16.66 Integ Capacity MBtuh 20 (-6.7) 2.30 2.30 2.31 2.21 2.20 2.21 2.12 2.11 2.12 Total Sys KW 22.21 21.99 21.72 22.51 22.30 22.07 22.81 22.60 22.35 Total 19.46 19.27 19.03 19.72 19.54 19.33 19.98 19.80 19.58 Integ Capacity MBtuh 30 (-1.1) 2.39 2.40 2.42 2.28 2.29 2.31 2.18 2.19 2.21 Total Sys KW OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 25.93 25.68 25.38 26.29 26.03 25.74 26.65 26.39 26.08 Total 28.69 25.95 23.91 24.73 24.69 28.25 25.54 23.51 23.88 23.84 27.68 25.00 23.00 22.88 22.83 Total 25.93 25.68 25.38 26.29 26.03 25.74 26.65 26.39 26.08 Integ 2.46 2.48 2.51 2.35 2.36 2.40 2.24 2.26 2.29 Total Sys KW 30.13 29.83 29.46 30.57 30.27 29.87 31.04 30.70 30.29 Total 16.98 21.86 20.68 24.73 24.69 16.11 20.48 19.42 23.88 23.84 15.20 19.04 18.09 22.88 22.83 Sens 50 (10) 3.17 3.15 3.14 3.14 3.14 3.14 3.12 3.10 3.11 3.11 3.10 3.08 3.07 3.07 3.07 Total Sys KW 30.13 29.83 29.46 30.57 30.27 29.87 31.04 30.70 30.29 Integ Capacity MBtuh 115 (46.1) Capacity MBtuh 40 (4.4) Capacity MBtuh *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 1125 / 0.21 1000 / 0.17 875 / 0.13 CFM / BF EVAPORATOR AIR PHD330 COOLING EXTENDED PERFORMANCE TABLE 125 (51.7) 2.54 2.57 2.62 2.43 2.46 2.50 2.32 2.35 2.39 Total Syst em KW 26.51 23.97 22.05 23.14 23.10 26.14 23.60 21.69 22.37 22.33 25.66 23.14 21.25 21.45 21.42 Total 35.14 34.70 34.18 35.70 35.27 34.73 36.29 35.83 35.28 Total 35.14 34.70 34.18 35.70 35.27 34.73 36.29 35.83 35.28 Integ Capacity MBtuh 60 (15.6) 16.17 20.96 19.77 23.14 23.10 15.32 19.64 18.56 22.37 22.33 14.44 18.24 17.29 21.45 21.42 Sens Capacity MBtuh 2.66 2.69 2.75 2.54 2.58 2.64 2.43 2.47 2.52 Total Syst em KW 3.53 3.51 3.50 3.51 3.51 3.49 3.48 3.47 3.47 3.47 3.46 3.45 3.44 3.44 3.44 Total Sys KW 8 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 518 14 2201 05 35.11 35.71 57 (13.9) 62 (16.7) 39.63 43.50 72 (13.9) 36.54 62 (16.7) 67 (19.4) 36.41 57 (13.9) 36.85 42.86 72 (13.9) 63* (17.2) 38.99 67 (19.4) 36.21 41.96 72 (13.9) 63* (17.2) 38.13 67 (19.4) 34.77 62 (16.7) 35.34 33.59 57 (13.9) 63* (17.2) Total EWB _F (_C) 23.36 29.59 28.29 36.49 36.41 22.23 27.86 26.69 33.01 35.11 21.04 26.06 25.01 30.70 33.59 Sens Capacity MBtuh 75 (23.9) 2.58 2.55 2.53 2.53 2.52 2.53 2.50 2.47 2.47 2.47 2.47 2.44 2.42 2.42 2.41 Total Sys KW 41.27 37.64 34.96 34.95 34.89 40.74 37.07 34.40 33.97 33.69 39.94 36.31 33.64 33.10 32.25 Total 22.59 28.75 27.46 34.95 34.89 21.48 27.06 25.89 32.07 33.69 20.31 25.28 24.23 29.87 32.25 Sens Capacity MBtuh 85 (29.4) 2.85 2.81 2.78 2.79 2.78 2.79 2.76 2.73 2.73 2.73 2.74 2.70 2.68 2.67 2.67 Total Sys KW 38.89 35.49 32.97 33.28 33.23 38.42 35.00 32.47 32.20 32.14 37.75 34.33 31.81 31.33 30.82 Total 21.74 27.86 26.58 33.28 33.23 20.68 26.20 25.03 32.20 32.14 19.54 24.46 23.40 28.94 30.82 Sens Capacity MBtuh 95 (35) 3.13 3.10 3.07 3.07 3.07 3.08 3.04 3.02 3.02 3.02 3.03 2.99 2.96 2.96 2.96 Total Sys KW 36.32 33.16 30.82 31.47 31.42 35.93 32.76 30.40 30.50 30.45 35.39 32.20 29.83 29.46 29.24 Total 20.81 26.89 25.61 31.47 31.42 19.82 25.27 24.10 30.50 30.45 18.70 23.57 22.52 27.90 29.24 Sens Capacity MBtuh 105 (40.5) 3.45 3.42 3.39 3.40 3.40 3.40 3.37 3.34 3.34 3.34 3.35 3.31 3.29 3.29 3.28 Total Sys KW CONDENSER ENTERING AIR TEMPERATURES _F (_C) Total 12.15 12.38 12.59 11.71 11.94 12.15 11.23 11.46 11.67 CFM 1050 1200 1350 1050 1200 1350 1050 1200 1350 10.74 10.55 10.33 11.18 10.99 10.77 11.58 11.39 11.18 Integ Capacity MBtuh -10 (-23.3) 2.59 2.56 2.53 2.47 2.44 2.41 2.35 2.32 2.30 Total Sys KW See Legend and Notes following tables. 75 70 65 EDB _F (_C) INDOOR AIR 14.91 14.68 14.42 15.37 15.13 14.88 15.79 15.57 15.31 Total 13.72 13.51 13.27 14.14 13.93 13.69 14.53 14.32 14.08 Integ Capacity MBtuh 0 (-17.8) 2.67 2.64 2.62 2.54 2.52 2.50 2.43 2.40 2.39 Total Sys KW 18.61 18.31 18.01 19.35 19.13 18.76 19.62 19.41 19.19 Total 17.08 16.81 16.53 17.76 17.55 17.22 18.01 17.82 17.61 Integ Capacity MBtuh 10 (-12.2) PHD336 HEATING EXTENDED PERFORMANCE TABLE 2.75 2.73 2.72 2.64 2.62 2.61 2.52 2.50 2.49 Total Sys KW 22.59 22.36 22.09 22.88 22.65 22.39 23.19 22.96 22.68 Total 20.48 20.27 20.03 20.75 20.54 20.31 21.03 20.82 20.57 Integ Capacity MBtuh 20 (-6.7) 2.84 2.83 2.84 2.71 2.70 2.70 2.59 2.58 2.58 Total Sys KW 26.53 26.27 25.96 26.91 26.63 26.32 27.29 27.01 26.68 Total 23.24 23.02 22.75 23.58 23.34 23.06 23.91 23.66 23.38 Integ Capacity MBtuh 30 (-1.1) 2.93 2.92 2.94 2.80 2.79 2.80 2.67 2.67 2.68 Total Sys KW OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 31.07 30.74 30.36 31.54 31.21 30.81 32.01 31.68 31.28 Total 33.56 30.65 28.48 29.45 29.41 33.26 30.32 28.14 28.61 28.57 32.82 29.86 27.67 27.56 27.50 Total 31.07 30.74 30.36 31.54 31.21 30.81 32.01 31.68 31.28 Integ 3.03 3.04 3.06 2.91 2.91 2.93 2.78 2.78 2.80 Total Sys KW 36.43 36.04 35.58 37.00 36.62 36.14 37.51 37.20 36.70 Total 19.82 25.82 24.53 29.45 29.41 18.85 24.25 23.09 28.61 28.57 17.81 22.59 21.55 27.56 27.50 Sens 50 (10) 3.82 3.78 3.76 3.77 3.77 3.76 3.73 3.71 3.71 3.71 3.71 3.68 3.66 3.66 3.66 Total Sys KW 36.43 36.04 35.58 37.00 36.62 36.14 37.51 37.20 36.70 Integ Capacity MBtuh 115 (46.1) Capacity MBtuh 40 (4.4) Capacity MBtuh *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 1350 / 0.24 1200 / 0.18 1050 / 0.12 CFM / BF EVAPORATOR AIR PHD336 COOLING EXTENDED PERFORMANCE TABLE 125 (51.7) 3.19 3.19 3.23 3.06 3.06 3.09 2.93 2.94 2.96 Total Sys KW 30.62 27.98 26.00 27.25 27.22 30.40 27.71 25.72 26.53 26.49 30.05 27.36 25.33 25.62 25.58 Total 42.11 42.15 41.77 42.49 42.62 42.42 42.82 43.06 42.99 Total 42.11 42.15 41.77 42.49 42.62 42.42 42.82 43.06 42.99 Integ Capacity MBtuh 60 (15.6) 18.76 24.63 23.34 27.25 27.22 17.82 23.14 21.97 26.53 26.49 16.85 21.54 20.50 25.62 25.58 Sens Capacity MBtuh 3.38 3.40 3.46 3.24 3.25 3.31 3.10 3.12 3.16 Total Sys KW 4.22 4.20 4.18 4.19 4.19 4.17 4.15 4.13 4.14 4.14 4.12 4.10 4.08 4.08 4.08 Total Sys KW 518 14 2201 05 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 9 40.11 40.77 41.23 44.54 48.87 41.67 41.78 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 49.79 47.71 72 (13.9) 72 (13.9) 43.43 67 (19.4) 45.42 40.17 63* (17.2) 67 (19.4) 39.60 62 (16.7) 42.07 38.29 57 (13.9) 63* (17.2) Total EWB _F (_C) 27.12 34.11 32.53 41.78 41.67 25.87 32.09 30.65 37.93 40.11 24.52 29.99 28.70 35.26 38.29 Sens Capacity MBtuh 75 (23.9) 2.95 2.87 2.83 2.82 2.82 2.89 2.82 2.77 2.77 2.76 2.83 2.76 2.72 2.71 2.70 Total Sys KW 47.20 43.10 39.93 40.00 39.92 46.39 42.33 39.19 38.83 38.48 45.36 41.34 38.23 37.74 36.78 Total 26.14 33.11 31.53 40.00 39.92 24.92 31.12 29.70 36.81 38.48 23.64 29.07 27.80 34.27 36.78 Sens Capacity MBtuh 85 (29.4) 3.26 3.18 3.13 3.13 3.13 3.20 3.12 3.07 3.07 3.06 3.14 3.07 3.02 3.01 3.00 Total Sys KW 44.53 40.66 37.70 38.10 38.04 43.82 40.00 37.04 36.82 36.73 42.91 39.13 36.20 35.79 35.17 Total 25.11 32.04 30.48 38.10 38.04 23.93 30.10 28.70 36.82 36.73 22.69 28.10 26.84 33.19 35.17 Sens Capacity MBtuh 95 (35) 3.62 3.53 3.48 3.49 3.48 3.56 3.48 3.42 3.42 3.42 3.50 3.42 3.37 3.36 3.35 Total Sys KW 41.74 38.14 35.35 36.09 36.04 41.13 37.55 34.77 34.91 34.85 40.34 36.80 34.04 33.74 33.43 Total 24.03 30.89 29.35 36.09 36.04 22.89 29.02 27.63 34.91 34.85 21.70 27.07 25.81 32.00 33.43 Sens Capacity MBtuh 105 (40.5) 4.04 3.95 3.88 3.90 3.90 3.98 3.89 3.83 3.83 3.83 3.91 3.83 3.77 3.76 3.76 13.54 13.72 13.88 13.21 13.40 13.57 12.79 12.99 13.17 1225 1400 1575 1225 1400 1575 1225 1400 1575 Total CFM 12.12 11.95 11.77 12.48 12.33 12.15 12.77 12.62 12.46 Integ Capacity MBtuh -10 (-23.3) 2.79 2.76 2.75 2.64 2.62 2.61 2.50 2.48 2.47 Total Sys KW See Legend and Notes following tables. 75 70 65 EDB _F (_C) INDOOR AIR 17.13 16.93 16.70 17.52 17.33 17.11 17.85 17.68 17.47 Total 15.76 15.58 15.37 16.12 15.95 15.75 16.43 16.26 16.08 Integ Capacity MBtuh 0 (-17.8) 2.93 2.92 2.91 2.79 2.78 2.77 2.65 2.64 2.63 Total Sys KW 21.86 21.59 21.03 22.13 21.94 21.74 22.30 22.14 21.96 Total 20.07 19.82 19.31 20.31 20.14 19.96 20.47 20.32 20.15 Integ Capacity MBtuh 10 (-12.2) PHD342 HEATING EXTENDED PERFORMANCE TABLE 3.06 3.05 3.05 2.92 2.91 2.92 2.78 2.77 2.78 Total Sys KW 25.85 25.64 25.41 26.14 25.93 25.70 26.41 26.21 25.98 Total 23.44 23.25 23.05 23.71 23.52 23.30 23.95 23.77 23.56 Integ Capacity MBtuh 20 (-6.7) 3.15 3.15 3.17 3.00 3.00 3.02 2.86 2.86 2.88 Total Sys KW 30.31 30.06 29.76 30.72 30.45 30.15 31.10 30.85 30.54 Total 26.56 26.34 26.07 26.91 26.68 26.42 27.25 27.03 26.76 Integ Capacity MBtuh 30 (-1.1) 3.23 3.24 3.27 3.09 3.10 3.12 2.95 2.95 2.98 Total Sys KW OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 35.46 35.15 34.76 35.97 35.67 35.27 36.50 36.18 35.78 Total Total 35.46 35.15 34.76 35.97 35.67 35.27 36.50 36.18 35.78 3.35 3.37 3.41 3.21 3.22 3.25 3.07 3.07 3.11 Total Sys KW 38.81 35.47 32.87 33.94 33.89 38.30 34.97 32.38 32.88 32.83 37.63 34.33 31.75 31.62 31.55 Integ Capacity MBtuh 41.48 41.24 40.75 41.84 41.86 41.37 42.12 42.43 42.01 Total 22.90 29.68 28.13 33.94 33.89 21.80 27.89 26.48 32.88 32.83 20.65 25.98 24.73 31.62 31.55 Sens 50 (10) 4.53 4.43 4.35 4.38 4.38 4.46 4.37 4.29 4.31 4.31 4.40 4.30 4.24 4.24 4.23 Total Sys KW 41.48 41.24 40.75 41.84 41.86 41.37 42.12 42.43 42.01 Integ Capacity MBtuh 115 (46.1) Capacity MBtuh 40 (4.4) Total Sys KW CONDENSER ENTERING AIR TEMPERATURES _F (_C) *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 1575 / 0.19 1400 / 0.17 1225 / 0.14 CFM / BF EVAPORATOR AIR PHD342 COOLING EXTENDED PERFORMANCE TABLE 125 (51.7) 3.53 3.56 3.61 3.37 3.40 3.44 3.22 3.24 3.30 Total Sys KW 35.71 32.65 30.26 31.61 31.57 35.30 32.23 29.83 30.69 30.65 34.75 31.69 29.30 29.58 29.53 Total 46.79 47.49 47.80 47.03 47.84 48.32 47.19 48.15 48.77 Total 46.79 47.49 47.80 47.03 47.84 48.32 47.19 48.15 48.77 Integ Capacity MBtuh 3.76 3.80 3.89 3.59 3.62 3.70 3.42 3.46 3.53 Total Sys KW 5.08 4.97 4.89 4.94 4.93 5.02 4.91 4.83 4.86 4.86 4.95 4.85 4.77 4.78 4.78 Total Sys KW 60 (15.6) 21.70 28.36 26.81 31.61 31.57 20.64 26.64 25.25 30.69 30.65 19.54 24.82 23.57 29.58 29.53 Sens Capacity MBtuh 10 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 518 14 2201 05 47.60 48.40 57 (13.9) 62 (16.7) 53.64 58.69 72 (13.9) 49.55 62 (16.7) 67 (19.4) 49.32 57 (13.9) 49.85 57.75 72 (13.9) 63* (17.2) 52.75 67 (19.4) 48.97 56.55 72 (13.9) 63* (17.2) 51.57 67 (19.4) 47.12 62 (16.7) 47.82 45.56 57 (13.9) 63* (17.2) Total EWB _F (_C) 31.53 39.78 38.00 49.16 49.32 30.14 37.49 35.87 44.34 47.60 28.57 35.10 33.66 41.32 45.56 Sens Capacity MBtuh 75 (23.9) 3.33 3.32 3.32 3.32 3.32 3.28 3.27 3.27 3.26 3.26 3.23 3.22 3.21 3.21 3.20 Total Sys KW 55.39 50.67 47.12 47.14 47.06 54.58 49.90 46.36 45.91 45.50 53.52 48.88 45.36 44.75 43.64 Total 30.29 38.49 36.74 47.14 47.06 28.93 36.26 34.67 42.93 45.50 27.50 33.93 32.52 40.06 43.64 Sens Capacity MBtuh 85 (29.4) 3.76 3.73 3.71 3.71 3.71 3.70 3.68 3.65 3.65 3.65 3.64 3.62 3.59 3.59 3.58 Total Sys KW 52.04 47.66 44.35 44.77 44.71 51.36 47.00 43.69 43.41 43.31 50.45 46.13 42.84 42.33 41.62 Total 29.02 37.17 35.44 44.77 44.71 27.71 35.00 33.44 43.41 43.31 26.34 32.74 31.34 38.74 41.62 Sens Capacity MBtuh 95 (35) 4.18 4.15 4.11 4.12 4.12 4.13 4.09 4.05 4.05 4.05 4.06 4.02 3.99 3.99 3.98 Total Sys KW 48.54 44.52 41.47 42.28 42.23 48.01 43.98 40.92 41.04 40.98 47.26 43.25 40.19 39.81 39.47 Total 27.70 35.78 34.07 42.28 42.23 26.44 33.69 32.15 41.04 40.98 25.12 31.49 30.11 37.27 39.47 Sens Capacity MBtuh 105 (40.5) 4.63 4.59 4.55 4.56 4.56 4.57 4.52 4.49 4.49 4.49 4.51 4.46 4.42 4.42 4.41 Total Sys KW CONDENSER ENTERING AIR TEMPERATURES _F (_C) 14.95 15.19 1800 14.68 1400 1600 15.76 1800 15.26 1400 15.52 16.24 1800 1600 16.01 15.76 1400 1600 Total CFM 13.98 13.76 13.51 14.50 14.28 14.04 14.94 14.73 14.50 Integ Capacity MBtuh -10 (-23.3) 3.29 3.25 3.22 3.15 3.11 3.08 3.02 2.98 2.95 Total Sys KW See Legend and Notes following tables. 75 (23.9) 70 (21.1) 65 (18.3) EDB _F (_C) INDOOR AIR 19.85 19.59 19.29 20.41 20.14 19.85 20.90 20.64 20.36 Total 18.27 18.03 17.74 18.78 18.53 18.27 19.23 18.99 18.74 Integ Capacity MBtuh 0 (-17.8) 3.39 3.36 3.34 3.25 3.22 3.20 3.12 3.09 3.07 Total Sys KW 24.78 24.47 24.12 25.33 25.04 24.68 25.85 25.55 25.22 Total 22.74 22.46 22.14 23.25 22.98 22.65 23.73 23.46 23.15 Integ Capacity MBtuh 10 (-12.2) PHD348 HEATING EXTENDED PERFORMANCE TABLE 3.51 3.48 3.47 3.36 3.34 3.33 3.23 3.21 3.20 Total Sys KW 30.19 29.76 29.34 31.28 30.99 30.13 31.63 31.36 31.05 Total 27.38 26.99 26.61 28.37 28.11 27.32 28.69 28.44 28.16 Integ Capacity MBtuh 20 (-6.7) 3.63 3.62 3.63 3.51 3.50 3.48 3.37 3.35 3.36 Total Sys KW 36.07 35.73 35.38 36.49 36.16 35.80 36.92 36.59 36.22 Total 31.60 31.31 31.00 31.97 31.68 31.37 32.35 32.06 31.73 Integ Capacity MBtuh 30 (-1.1) 3.79 3.79 3.82 3.63 3.63 3.65 3.48 3.48 3.50 Total Sys KW OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 41.72 41.31 40.85 42.28 41.87 41.40 42.84 42.42 41.94 Total 44.88 41.22 38.44 39.60 39.55 44.45 40.79 37.98 38.53 38.48 43.85 40.21 37.38 37.23 37.15 Total 41.72 41.31 40.85 42.28 41.87 41.40 42.84 42.42 41.94 Integ 3.93 3.94 3.98 3.76 3.78 3.81 3.60 3.61 3.65 Total Sys KW 48.30 47.80 47.21 49.01 48.48 47.87 49.72 49.17 48.55 Total 26.31 34.28 32.60 39.60 39.55 25.09 32.28 30.76 38.53 38.48 23.83 30.17 28.81 37.23 37.15 Sens 50 (10) 5.12 5.07 5.03 5.05 5.05 5.06 5.01 4.97 4.98 4.98 4.99 4.95 4.91 4.91 4.90 Total Sys KW 48.30 47.80 47.21 49.01 48.48 47.87 49.72 49.17 48.55 Integ Capacity MBtuh 115 (46.1) Capacity MBtuh 40 (4.4) Capacity MBtuh *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 1800 / 0.21 1600 / 0.18 1400 / 0.15 CFM / BF EVAPORATOR AIR PHD348 COOLING EXTENDED PERFORMANCE TABLE 125 (51.7) 4.09 4.12 4.18 3.91 3.94 4.00 3.74 3.77 3.83 Total Sys KW 41.06 37.75 35.24 36.70 36.65 40.74 37.41 34.88 35.81 35.76 40.27 36.94 34.39 34.69 34.64 Total 56.12 55.56 54.77 56.82 56.38 55.58 57.48 57.12 56.41 Total 56.12 55.56 54.77 56.82 56.38 55.58 57.48 57.12 56.41 Integ Capacity MBtuh 60 (15.6) 24.85 32.65 30.98 36.70 36.65 23.69 30.77 29.27 35.81 35.76 22.48 28.75 27.41 34.69 34.64 Sens Capacity MBtuh 4.28 4.35 4.43 4.09 4.15 4.24 3.90 3.95 4.05 Total Sys KW 5.65 5.60 5.57 5.59 5.59 5.59 5.55 5.52 5.53 5.53 5.53 5.49 5.46 5.46 5.46 Total Sys KW 518 14 2201 05 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 56.42 58.00 58.78 63.34 69.39 56.94 58.33 59.07 63.63 69.68 60.87 60.95 61.07 65.61 71.73 56.42 51.82 42.05 43.86 35.42 56.94 52.61 42.62 44.47 35.83 60.87 60.95 47.50 49.74 39.07 75 (23.9) Capacity MBtuh Total Sens 3.97 3.99 4.00 4.05 4.13 3.99 4.01 4.02 4.08 4.15 4.19 4.19 4.19 4.25 4.33 Total Sys KW 54.09 55.15 55.87 60.17 65.81 54.57 55.44 56.12 60.42 66.07 58.14 58.23 57.83 62.14 67.82 54.09 50.34 40.69 42.48 34.15 54.57 51.08 41.24 43.08 34.51 58.14 58.23 46.01 48.23 37.60 85 (29.4) Capacity MBtuh Total Sens 4.39 4.40 4.41 4.47 4.55 4.41 4.42 4.43 4.49 4.57 4.61 4.61 4.61 4.67 4.75 Total Sys KW 51.60 52.19 52.77 56.78 62.02 52.03 52.47 53.00 57.00 62.25 55.23 55.31 54.45 58.42 63.70 51.60 48.67 39.25 41.02 32.72 52.03 49.35 39.80 41.60 33.07 55.23 55.31 44.43 46.60 36.05 4.86 4.87 4.88 4.94 5.02 4.88 4.89 4.90 4.96 5.04 5.08 5.08 5.07 5.13 5.21 48.89 49.10 49.45 53.14 57.99 49.27 49.36 49.63 53.31 58.17 52.05 52.12 50.81 54.47 59.34 48.89 48.72 37.72 39.45 31.19 49.27 49.36 38.25 40.02 31.52 52.05 52.12 42.69 44.84 34.41 5.40 5.40 5.41 5.46 5.54 5.42 5.42 5.42 5.48 5.56 5.62 5.62 5.60 5.66 5.74 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity MBtuh Capacity MBtuh Total Total Total Sens Total Sens Sys KW Sys KW 3.62 3.63 3.75 3.77 3.78 3.90 3.93 3.94 4.06 1750 1800 2250 1750 1800 2250 1750 1800 2250 17.72 17.79 18.45 16.90 16.97 17.62 16.04 16.12 16.73 19.26 19.34 20.06 18.37 18.45 19.15 17.44 17.52 18.19 CFM 24.88 24.98 25.74 24.01 24.11 24.92 23.12 23.22 23.99 22.89 22.98 23.69 22.09 22.18 22.93 21.27 21.36 22.07 0 (-17.8) Capacity MBtuh Total Integ 3.77 3.78 3.88 3.92 3.93 4.04 4.09 4.10 4.21 Total Sys KW 30.79 30.90 31.75 30.00 30.11 30.96 29.18 29.28 30.13 28.26 28.37 29.14 27.54 27.64 28.41 26.78 26.88 27.65 = tlwb 1.10 x cfm Sensible capacity (Btuh) air leaving evaporator coil (hlwb) Wet-bulb temperature corresponding to enthalpy = tedb - tldb 3.91 3.92 4.00 4.08 4.09 4.17 4.26 4.27 4.35 10 (-12.2) Capacity Total MBtuh Sys Total Integ KW LEGEND BF - Bypass Factor edb - Entering Dry-Bulb Ewb - Entering Wet-Bulb kW - Total Unit Power Input SHC - Sensible Heat Capacity (1000 Btuh) TC - Total Capacity (1000 Btuh) (net) rh - Relative Humidity COOLING NOTES: 1. Ratings are net; they account for the effects of the evaporator-fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: 75 70 65 EDB _F (_C) INDOOR AIR -10 (-23.3) Capacity Total MBtuh Sys Total Integ KW PHD360 HEATING EXTENDED PERFORMANCE TABLE 45.87 45.94 45.84 49.23 53.69 46.23 46.30 45.98 49.37 53.84 48.61 48.67 46.95 50.28 54.72 37.20 37.33 38.31 36.36 36.49 37.44 35.57 35.70 36.62 33.74 33.85 34.75 32.98 33.09 33.95 32.26 32.37 33.21 = hewb - 44.98 45.09 45.93 44.47 44.58 45.42 43.08 43.34 44.87 39.41 39.50 40.25 38.96 39.06 39.80 37.74 37.97 39.31 51.96 52.09 53.12 51.32 51.43 52.45 50.66 50.78 51.79 51.96 52.09 53.12 51.32 51.43 52.45 50.66 50.78 51.79 4.5 x cfm total capacity (Btuh) 4.26 4.26 4.28 4.46 4.45 4.47 4.63 4.64 4.68 4.43 4.42 4.41 4.63 4.63 4.61 4.85 4.84 4.82 60.02 60.19 61.48 59.22 59.39 60.65 58.44 58.60 59.83 60.02 60.19 61.48 59.22 59.39 60.65 58.44 58.60 59.83 50 (10) Capacity MBtuh Total Integ 6.01 6.01 6.01 6.06 6.13 6.03 6.03 6.03 6.08 6.15 6.22 6.22 6.19 6.25 6.32 Total Sys KW 4.64 4.62 4.58 4.85 4.83 4.79 5.07 5.05 5.00 Total Sys KW 42.60 42.66 42.01 45.09 49.14 42.88 42.94 42.13 45.20 49.25 44.88 44.93 42.89 45.90 49.88 69.62 69.84 71.51 68.63 68.85 70.47 67.67 67.87 69.45 69.62 69.84 71.51 68.63 68.85 70.47 67.67 67.87 69.45 60 (15.6) Capacity MBtuh Total Integ 42.60 42.66 34.26 35.96 27.85 42.88 42.94 34.74 36.48 28.16 44.88 44.93 38.69 40.82 30.83 125 (51.7) Capacity MBtuh Total Sens 4.91 4.89 4.81 5.12 5.10 5.02 5.35 5.33 5.24 Total Sys KW 6.70 6.70 6.69 6.74 6.80 6.72 6.72 6.71 6.75 6.82 6.90 6.90 6.87 6.92 6.98 Total Sys KW Where: hewb = Enthalpy of air entering evaporator coil 4. The SHC is based on 80_F (26.7_C) edb temperature of air entering evaporator coil. Below 80_F (26.7_C) edb, subtract (corr factor x cfm) from SHC. Above 80_F (26.7_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb + 80). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 6. The SHC is based on 80_F (26.7_C) edb temperature of air entering evaporator coil. Below 80_F (26.7_C) edb, subtract (corr factor x cfm) from SHC. Above 80_F (26.7_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb + 80). 7. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. hlwb 4.06 4.07 4.12 4.24 4.24 4.30 4.43 4.43 4.48 Total Sys KW 45.87 45.94 36.06 37.77 29.56 46.23 46.30 36.56 38.31 29.88 48.61 48.67 40.79 42.93 32.67 115 (46.1) Capacity MBtuh Total Sens OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 20 (-6.7) 30 (-1.1) 40 (4.4) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh Sys Sys Total Integ Total Integ Total Integ KW KW *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 2250 / 0.27 1850 / 0.20 1750 / 0.19 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) EVAPORATOR AIR EWB CFM / BF _F (_C) PHD360 COOLING EXTENDED PERFORMANCE TABLE 12 24 30 36 PHD3 36 30 24 PHD3 UNIT DIMENSIONS, PHD324−36 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 518 14 2201 05 518 14 2201 05 42 48 60 PHD3 42 48 60 PHD3 UNIT DIMENSIONS, PHD342−60 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 13 C0NNECTION WIRING SCHEMATIC − PHD3 208/230−1−60 14 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 518 14 2201 05 LADDER WIRING SCHEMATIC − PHD3 208/230−1−60 518 14 2201 05 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 15 CONTROLS Operating sequence When power is supplied to unit, the transformer (TRAN) is energized. On units with crankcase heater, heater is also energized. Cooling — With the thermostat in the cooling position, the thermostat makes circuit “R” to “O”. This energizes the reversing valve solenoid (RVS) and places the unit in standby condition for cooling. As the space temperature rises, the thermostat closes circuit “R” to “Y”. A circuit is made to contactor (C), starting the compressor (COMP) and outdoor−fan motor (OFM). Circuit “R” to “G” is made at the same time and starts the indoor−fan motor (IFM). When the thermostat is satisfied, contacts open, deenergizing C. The COMP and OFM stop, and the IFM stops after the preselected time delay. On the loss of the thermostat call for cooling, 24 V is removed from both the “Y1/Y” and “G” terminals (provided the fan switch is in the “AUTO” position) de−energizing the compressor contactor and opening the contacts supplying power to compressor/OFM. After a 90−second delay, the IFM shuts off. If the thermostat fan selector switch is in the “ON” position, the IFM will run continuously. 16 Heating — On a call for heat, thermostat makes circuits “R” to “Y” and “R” to “G”. A circuit is made to C, starting COMP and OFM. Circuit “R” to “G” also is completed, energizing IFR and starting IFM after the selected time delay. Should room temperature continue to fall, circuit “R” to “W” is made through second−stage thermostat. If optional electric heat package is used, a relay is energized, bringing on first bank of supplemental electric heat. When thermostat is satisfied, contacts open, deenergizing contactor and relay; motors and heaters deenergize. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 518 14 2201 05 ACCESSORIES ROOF CURBS HVAC unit base rails B HVAC unit basepan Dashed lines show cross support location for large basepan units. C Sealing Gasket F Roofcurb Anchor screw Wood nailer* A Flashing field supplied Roofcurb* Insulation (field supplied) Roofing material field supplied Cant strip field supplied E D COMMON CURB A09096 *Provided with roofcurb A09090 ROOF CURB DETAIL B C SUPPLY AIR SMALL BASE UNIT RETURN AIR LARGE BASE UNIT F A E D UNIT PLACEMENT ON COMMON CURB LARGE CURB UNIT SIZE Small or Large Large CATALOG NUMBER CPRFCURB010A00 CPRFCURB011A00 CPRFCURB012A00 CPRFCURB013A00 SMALL OR LARGE BASE UNIT A09095 A IN. (mm) 11 (279) 14 (356) 11 (279) 14 (356) B (small base) IN. (mm)* A09094 B (large base) IN. (mm)* C IN. (mm) D IN. (mm) 14 (356) 16 (406) 47.8 (1214) 10 (254) E IN. (mm) F IN. (mm) 32.4 (822) N/A 2.7 (69) 43.9 (1116) * Part Numbers CPRCURB010A00 and CPRCURB011A00 can be used on both small and large basepan units. The cross supports must be located based on whether the unit is a small basepan or a large basepan. NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied, as required, to unit being installed. 3. Roof curb is made of 16−gauge steel. 4. Attach ductwork to curb (flanges of duct rest on curb). 5. Insulated panels: 1−in. (25.4 mm) thick fiberglass 1 lb. density. 518 14 2201 05 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 17 PHD3 ACCESSORIES (continued) Accessory Model Number Description Use With Model Size ROOF CURBS CPRFCURB010A00 Roof Curb, 11” High CPRFCURB011A00 Roof Curb, 14” High CPRFCURB012A00 Roof Curb, 11” High CPRFCURB013A00 Roof Curb, 14” High Note: CPRFCURB010A00 AND CPRFCURB011A00 can be used with 42−60 size units with some overhang. 24 − 60 24 − 60 42 − 60 42 − 60 ADAPTER CURBS* CPADCURB001A00 CPADCURB002A00 Adapter curb for use with NPRFCURB006A00 & NPRFCURB007A00 Adapter curb for use with NPRFCURB008A00 & NPRFCURB009A00 24 − 36 42 − 60 * Can also be used when replacing other manufacturer’s older generation units that contain a composite base without a metal base rail. CONCENTRIC ADAPTERS − (Use with curb only) NPCONADP001A00 For 18” round duct (use with curbs CPRFCURB010A00, CPRFCURB011A00) Small Curb NPCONADP002A00 For 18” round duct (use with curbs CPRFCURB012A00, CPRFCURB013A00) Large Curb CONCENTRIC DIFFUSERS − (Ceiling or under roof)) AXB020CSA* Step Down Diffuser − Fits 2’ x 4’ Ceiling Grid (16” round collars for flex conn.) 24 − 42 AXB020CFA* Flush Mount Diffuser − Fits 2’ x 4’ Ceiling Grid (16” round collars for flex conn.) 24 − 42 AXB030CSA Step Down Diffuser − Fits 2’ x 4’ Ceiling Grid (18” round collars for flex conn.) 24 − 60 AXB030CFA Flush Mount Diffuser − Fits 2’ x 4’ Ceiling Grid (18” round collars for flex conn.) 24 − 60 * A field supplied 18” to 16” round reducer required when used with NP concentric adaptor ECONOMIZERS Dedicated Vertical Economizer − Internal with solid state controller, gear driven, fully modulatCPECOMZR007A00 ing damper, spring return actuator, up to 50% barometric relief, supply and dry bulb outdoor CPECOMZR008A00 air sensors. Includes filter rack with 1” filters*. CPECOMZR009A00 Dedicated Horizontal Economizer − Internal with solid state controller, fully modulating CPECOMZR010A00 damper, spring return actuator, supply and dry bulb outdoor air sensor, and low ambient comCPECOMZR011A00 pressor lockout switch included. Includes filter rack with 1−inch filters*. CPECOMZR012A00 CPRLYKIT001A00 Economizer relay for heat pumps AXB078ENT Outdoor Enthalpy Control * Outdoor enthalpy available as field installed accessory; Filter rack and 1” filter, same as CPFILTRK kit MANUAL FRESH AIR DAMPERS CPMANDPR007A00 CPMANDPR008A00 CPMANDPR009A00 Manual Outside Air Damper − (Includes filter rack and 1” filter, same as CPFILTRK kit) INTERNAL FILTER RACK and FILTER (shipped with 1” filters) CPFILTRK007A00 CPFILTRK008A00 CPFILTRK009A00 24 − 36 42, 48 60 24 − 36 42, 48 60 ALL ALL 24 − 36 42, 48 60 24 − 36 42, 48 60 Internal Filter Rack LOW AMBIENT, ANTI−CYCLE TIMER, COMPRESSOR START ASSIST CPLOWAMB001A00 NRTIMEGD001A00 CPHSTART002A00 Low Ambient Control − enables cooling system to operate down to 0 Deg. F by cycling condenser fan on and off. Five Minute Compressor Delay PTC Compressor Start Assist Kit CRANKCASE HEATER − BELLY BAND TYPE NPCRKHTR008A00 NPCRKHTR004A00 240V Crankcase Heater (included on 30 size) 240V Crankcase Heater (included on 60 size) ALL ALL ALL 24, 36 48 HAIL GUARDS / COIL PROTECTION (Factory installed on PHD3**000KTP models) NAPA00501GR NAPA00601GR NAPA01001GR ELECTRIC HEATERS PART NO. EHNA05K0N EHNA05K4F EHNA07K4F EHNA10K4F EHNA15K6F EHNA20K6F 3/8” spacing dense wire grilles 3/8” spacing dense wire grilles 3/8” spacing dense wire grilles 24 − 36 42 − 48 60 208/240V NOMINAL CAPACITY (kW) 3.8 / 5.0 3.8 / 5.0 5.4 / 7.2 7.5 / 10.0 11.3 / 15.0 15.0 / 20.0 FUSED NO YES YES YES YES YES # FUSES 0 4 4 4 6 6 STAGES 1 1 2 2 2 2 USE WITH 24 − 36 ALL ALL ALL 30 − 60 42 − 60 DUAL POINT WIRING KIT CPDUALPT001A00 Dual Point Wiring kit, 5−20kW Heaters NPDUCFLG002A00 Square to Round (1 set of 2, use with horizontal duct flanges only) DUCT TRANSITIONS ALL 24 − 48 International Comfort Products, LLC Lewisburg, Tennessee 37091 USA www.GoDayandNight.com 18 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 518 14 2201 05 ">
Advertisement