SAFETY TEST REPORT

SAFETY TEST REPORT
www.ecmg-global.com.cn
S AFETY T EST R EPORT
On Model Name: LCD TV
Model Number: 19L****, 20L****, 22L****, 23L****
Trademark: N/A
Prepared for Shenzhen KTC Technology Co., Ltd.
According to
EN 60065:2002+A1:2006+A11:2008
Audio, Video and similar electronic apparatus – Safety requirements
Test Report #:
SHE-1007-10462-LVD
Prepared by:
Shally Peng
Reviewed by:
Swall Zhang
QC Manager:
Swall Zhang
Test Report Released By:
Nov 02, 2010
⎯⎯⎯⎯⎯⎯⎯⎯⎯ ⎯⎯⎯⎯⎯
Swall Zhang
Date
Table of Contents
Disclaimer Notice .......................................................................................................1
Reproduction Clause...................................................................................................1
GENERAL REQUIREMENTS ............................................................................................5
GENERAL CONDITIONS OF TESTS.................................................................................5
MARKING ....................................................................................................................5
HAZARDOUS RADIATION.............................................................................................6
HEATING UNDER NORMAL OPERATING CONDITIONS ...................................................6
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK .................................................................................6
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS .........................8
INSULATION REQUIREMENTS .......................................................................................9
FAULT CONDITIONS ....................................................................................................9
MECHANICAL STRENGTH...........................................................................................10
CLEARANCE AND CREEPAGE DISTANCES....................................................................10
COMPONENTS...........................................................................................................11
TERMINALS ...............................................................................................................15
EXTERNAL FLEXIBLE CORDS External flexible cord is tested with end products. .........17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS.............................................18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST THE
EFFECTS OF IMPLOSION ....................................................................................18
STABILITY AND MECHANICAL HAZARDS ....................................................................19
RESISTANCE TO FIRE .................................................................................................19
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH PROTECTION
AGAINST SPLASHING WATER.............................................................................20
APPENDIX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS.......................................................................................................20
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS ........................................21
ANNEX ZC TO EN 60 065, A-DEVIATIONS..................................................................22
TABLE: Humidity Test ...............................................................................................30
TABLE: Mechanical strength-impact test ...................................................................35
STRESS RELIEF TEST ..................................................................................................35
TABLE: Screws and connections test..........................................................................41
Attachment 1- Circuit Diagram.................................................................................42
Attachment 2- EUT Photos........................................................................................43
Disclaimer Notice
When government drawing, specification, or other data are used for
any purpose other than in connection with a definitely related
government procurement operation, the United States Government
thereby incurs no responsibility nor any obligation whatsoever; and
the fact that the Government may have formulated, furnished, or in
any way supplied the said drawing, specifications, or other data, is
not to be regarded by implication or otherwise in any manner
licensing the holder or any other person or corporation, or
conveying any rights or permission to manufacture, use, or sell
patented invention that may in any way be related thereto. This
report must not be used to claim product endorsement by NVLAP or
any agency of the U.S. Government.
Reproduction Clause
Any reproduction of this document must be done in full. No single
part of this document may be reproduced without permission from
EMC Compliance Management Group.
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 1 of 48
TEST REPORT
EN 60065
Audio, video and similar electronic apparatus
Safety requirements
Report Reference No.........................: SHE-1007-10462-LVD
Tested by (+ signature) ......................: Shally Peng
Approved by (+ signature)..................: Swall Zhang
Date of issue .......................................: 2010-11-02
Contents..............................................: 51 Pages Total including the front pages.
Testing laboratory Name .................: EMC Compliance Management Group.
Address...............................................: Room 707, West 7/F, Building 201 Tairan Road 4, Chegongmiao
Industrial Estate, Futian District, Shenzhen, China
Testing location...................................: Same as above
Client Name .......................................: Shenzhen KTC Technology Co., Ltd.
Address...............................................: Northern Wuhe Road,Gangtou, Buji, Longgang, Shenzhen, China
Standard .............................................: EN 60065:2002+A1:2006+A11:2008
Test procedure ...................................: LVD
Non-standard test method..................: N/A
Test Report Form/blank test report
Test Report Form No..........................: IECEN60065F
TRF originator.....................................: BEAB
Master TRF.........................................: Dated 2003-02
Copyright @ 2003 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE),
Geneva, Switzerland. All rights reserved.
This publication may be produced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright
owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader’s
interpretation of the reproduced material due to its placement and context
Test item Description..........................: LCD TV
Trademark...........................................: N/A
Model and/or type reference ..............: 19L****, 20L****, 22L****, 23L**** (”*” can be ”0-9”or ”A-Z”
or ”Blank” to indicate the different code of the client or the different
sales territory)
Manufacturer.......................................: Shenzhen KTC Technology Co., Ltd.
Model tested ........................................ 19L11A, 23L11
Rating(s) .............................................: 19L****:100-240V~, 50/60Hz, Max 35W
20L****:100-240V~, 50/60Hz, Max 35W
22L****:100-240V~, 50/60Hz, Max 35W
23L****:100-240V~, 50/60Hz, Max 40W
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 2 of 48
Test case verdicts
Test case does not apply to the test object ..................: N(.A.)
Test item does meet the requirement ...........................: P(ass)
Test item does not meet the requirement .....................: F(ail)
Testing
Date of receipt of test item ............................................: 2010.10.24
Date(s) of performance of test………………………:
2010.10.24 to 10.30
General remarks
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.
"(see remark #)" refers to a remark appended to the report.
"(see Annex #)" refers to an annex appended to the report.
Throughout this report a comma is used as the decimal separator.
Summary of Testing and Conclusions
The sample(s) tested complies with the requirements of EN 60065:2002+A1:2006+A11:2008. Compliance
with European Special National Conditions, Annex ZB, and A – Deviations, Annex ZC, is recorded at the end
of this report.
The equipment has been evaluated for maximum ambient temperature of +40°C according to user manual.
Model Description:
For Model series 19L****, 20L****, 22L**** and 23L****, the means of “*” is as below :
“*”can be “0-9” or “A-Z” or “Blank” to indicate the different code of the client or the different sales territory.
Series models 19L****, 20L****, 22L**** and 23L**** are identical to each other except for LCD Panel with
control board, enclosure size and model designation;
All models in each series are identical to each other except for model designation.
So we select the model number 19L11A and 23L11 to test.
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 3 of 48
Copy of marking plate:
Take model 19L11A, 20L11, 22L11A and 23L11 for example:
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 4 of 48
EN 60065
Clause
Requirement – Test
3
GENERAL REQUIREMENTS
P
Safety class of the apparatus .................................: Class I
P
4
GENERAL CONDITIONS OF TESTS
P
4.1.4
Ventilation instructions require the use of the test
box
5
MARKING
P
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
P
Identification, maker, model ....................................: Refer to marking label
P
Class II symbol if applicable
N
Rated supply voltage and symbol ..........................: 100-240V~
P
Frequency if safety dependant
P
5.1
Result - Remark
Verdict
Yes
P
50/60Hz
Rated current or power consumption .....................: Max 35W for model 19L****,
20L**** and 22L****,
Max 40W for model 23L****,
See appended Table 5.1
P
Earth terminal
Class I equipment
P
Hazardous live terminals
No such terminal
N
Supply output terminals (other than mains)
No such terminal
N
5.3
Use of triangle with exclamation mark
Such symbol is indicated on
circuit diagram for specific
components.
P
5.4
Instructions for use
User’s manual is provided in
English
P
5.4.1
Mains powered equipment not exposed to dripping Refer to user manual.
or splashing. Warning concerning objects filled
with liquid, etc.
P
Hazardous live terminals, instructions for wiring
Not applicable
N
Instructions for replacing lithium battery
No lithium battery
N
Instructions for modem if fitted
No any modem
N
5.2
5.4.2
Class I earth connection warning
P
Instructions for multimedia system connection
P
Special stability warning for fixed installation
N
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
All pole switch used.
P
Instructions for permanently connected equipment
Not a permanently connected
equipment.
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 5 of 48
EN 60065
Clause
Requirement – Test
6
HAZARDOUS RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
6.1
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N
Laser radiation, emission limits to IEC 60825-1 ....: LEDs for indication considered
inherently Class 1
P
Emission limits under fault conditions ....................: Class 1
P
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified values, (see appended table 7.1)
no operation of fuse links
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as (see appended table 7.1)
a mechanical barrier
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150 oC
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
No changing voltage setting
device etc.
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
No such hygroscopic material.
N
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
No risk of electric shock
P
8.5
Class I equipment
EN 60065
6.2
Result - Remark
Verdict
N
There is no CRT. No Ionizing
Radiation generated.
N
P
Basic insulation between hazardous live parts and
earthed accessible parts
Basic insulation complies with
requirements specified in
clause 10 and 13.
P
Resistors bridging basic insulation complying with
14.2.1 a)
No resistors bridging basic
insulation.
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 6 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.6
Class II equipment and Class II constructions
within Class I equipment
See below.
P
Reinforced or double insulation between
hazardous live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
1) The apparatus have
isolating transformers (T01)
complies with clause 14.3.
2) Optocoupler (IC2) complies
with 14.11.
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
Certified capacitors CY1, CY2
are approved components, see
appended table 14.
P
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
N
Certified capacitors CY3 is
approved components, see
appended table 14.
P
Basic insulation bridged by components complying None
with 14.3.4.3
N
8.7
This clause is voided.
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) : The thickness of
supplementary insulation used
in wire >0.4mm
P
Reinforced insulation > 0,4 mm (mm) ....................: a. Transformer bobbin: min.
0.4mm thickness.
b. Optocouplers inner
insulation, ref. 14.11.
P
Thin sheet insulation
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
P
Basic or supplementary insulation, three layers any
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
P
8.9
8.10
Adequate insulation between internal hazardous
live conductors and accessible parts
Double insulated.
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
All internal live parts are
separated by reinforced or
double insulation between
accessible parts.
P
Double insulation between conductors connected
to the mains and accessible parts
Class I apparatus
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 7 of 48
EN 60065
Clause
Requirement – Test
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
Result - Remark
Verdict
P
Internal wires fixed by cable
ties and connectors.
P
Vibration test carried out .........................................: No wire detached after test.
P
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
P
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
No windows, lenses, etc
N
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
See appended table 8.14.
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
No hot parts and sharp edges
can be touched.
P
8.16
Only special supply equipment can be used
Not such equipment.
N
8.17
Insulated winding wire without additional
interleaved insulation
Not applicable.
N
8.18
Endurance test as required by 8.17
Not applicable.
N
8.19
Disconnection from the mains
8.19.1
Disconnect device
All-pole switch used.
P
All-pole switch or circuit breaker with >3mm
contact separation
VDE approved.
P
8.19.2
Mains switch ON indication
Symbol used complies with
clause 5.
P
8.20
Switch not fitted in the mains cord
8.21
Bridging components comply with clause 14
No such components bridging
switch
N
8.22
Test specifications of non-separable thin sheet
material(+A1)
Not applicable.
N
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
9.1.1.1
Touch current measured from terminal devices
Refer to appended table 9.1.1
using the network in annex D .................................:
P
Discharge not exceeding 45 μC
P
Energy of discharge not exceeding 350 mJ
N
P
N
Not applicable
N
9.1.1.2
Test with test finger and test probe
No accesses of hazardous live
with the test finger and test
probe.
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
No such components
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 8 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
No hazard.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
No hazard.
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
No hazard.
P
9.1.5
Pre-set controls tested with 2 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
No such pre-set controls.
N
9.1.6
No shock hazard due to stored charge on
After conducted at least 10
withdrawal of the mains plug; voltage (V) after 2 s : times, the measured voltage
after 2s is 0V.
P
If C is not greater than 0,1 μF no test needed
N
Enclosure sufficiently resistant to external force
P
9.1.7
Verdict
Test probe 11 of IEC 61032 for 10 s (50 N)
No damage.
P
Test hook of fig. 4 for 10 s (20 N)
No damage.
P
30 mm diameter test tool for 5 s (100 or 250 N) ....: 100N applied, no damage.
P
9.2
No hazard after removing a cover by hand
N
10
INSULATION REQUIREMENTS
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after Class I apparatus.
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
N
10.2
Humidity treatment 48 h or 120 h ...........................: 30°C, 93% rh chamber for 48
hours
P
10.3
Insulation resistance and dielectric strength
P
11
FAULT CONDITIONS
11.1
No shock hazard under fault condition
See appended table 11.1
P
11.2
Heating under fault condition
See appended table
11.2(con’t)
P
No hazard from softening solder
No such condition
P
11.2.1
Measurement of temperature rises
see appended table 11.2(con’t)
P
11.2.2
Temperature rise of accessible parts
see appended table 11.2(con’t)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
see appended table 11.2(con’t)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
The temperature rise of PCB
board does not exceed the limit
of table 3.
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Cover can’t be removed by
hand
See appended table 10.3
P
Page 9 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
No conductors are
interrupted / peeled / loosened
during fault conditions.
Class I protective earthing maintained
P
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
Temperature rises are within
the limits
P
11.2.5
Temperature rise of windings
See appended table
11.2(con’t)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
See appended table
11.2(con’t)
P
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass >7 kg
<7kg
N
12.1.2
Vibration test
Yes, no hazard.
P
12.1.3
Impact hammer test
After the test, the apparatus
can withstand the dielectric
strength test as specified in
10.3 and show no damage.
P
Steel ball test
See appended table 12.1.3
P
P
12.1.4
Drop test for portable apparatus where mass < 7kg No hazard.
P
12.1.5
Thermoplastic enclosures strain relief test
70°C, See appended table
12.1.5
P
12.2
Fixing of knobs, push buttons, keys and levers
Push buttons are fastened
that their use did not impair
the protection against electric
shock.
P
12.3
Remote controls with hazardous live parts
12.4
Drawers (pull test 50 N, 10 s)
No drawers.
N
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial sockets
direct connect primary circuit.
N
12.6
Telescoping or rod antennas construction
No such construction
N
12.6.1
Telescoping or rod antennas securement
No such construction
N
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
See clause 13.3
P
Creepage distances in accordance with 13.4
See clause 13.4
P
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
N
P
Page 10 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
13.2
Determination of operating voltage
See appended table 13.2
P
13.3
Clearances
See appended table 13.3
P
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
13.3.3
Circuits not conductively connected to the mains
comply with table 10
13.3.4
Measurement of transient voltages
13.4
Creepage distances
P
No such construction provided
N
N
See appended table 13.2
Creepage distances greater than table 11 minima
P
P
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
No such construction
N
Conductive parts along reliably cemented joints
comply with 8.8
No such construction
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
No such construction
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
Opto-couplers meet the
requirements
P
14
COMPONENTS
P
14.1
Resistors
P
14.2
No such PCB used
N
a) Resistors between hazardous live parts and
accessible metal parts
No such resistors.
N
b) Resistors, other than between hazardous live
parts and accessible parts
Three bleeder resistors (RXA,
RXB, RXC, RXD) connected
between Live and Neutral in
series, located after fuse.
Shorting-circuit or
disconnecting of resistor does
not cause infringement of the
requirement for operation
under fault conditions.
N
c) Resistors separately approved ...........................: No such component
N
Capacitors and RC units
See below
P
Capacitors separately approved
See below
P
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 11 of 48
EN 60065
Clause
Requirement – Test
14.2.1
Y capacitors tested to IEC 60384-14, 2nd edition ...: Y1 or Y2 capacitors(CY1,CY2,
CY3) certified according to IEC
60384-14: 2nd edition.
P
14.2.2
X capacitors tested to IEC 60384-14, 2nd edition ...: X2 capacitors (CX2) certified
according to IEC 60384-14:
2nd edition.
P
14.2.3
Capacitors operating at mains frequency but not
No such capacitor used.
connected to the mains: tests for X2 ......................:
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better .......................................................................:
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................:
N
Shielded by a barrier to V-0 or metal .....................:
N
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
N
Transformers and inductors marked with
manufacturer's name and type ...............................:
P
Transformers and inductors separately approved .:
N
14.3.2
General
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
Transformers complied with
clause 13.
P
14.3.3.2
Transformers meet the constructional
requirements
Checked by inspection.
P
14.3.4.1
Class II transformers have adequate separation
Double or reinforced insulation
between hazardous live parts and accessible parts between hazardous live
(double or reinforced insulation)
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm
The bobbin: > 0.4mm
thickness.
N
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
Transformer is evaluated with
Class II construction.
N
14.3.4.3
Separating transformers with at least basic
insulation
N
14.3.5.1
Class II transformers have adequate insulation
Double or reinforced insulation
between hazardous live parts and accessible parts between hazardous live
(double or reinforced insulation)
windings and accessible
conductive parts.
P
14.3
14.3.1
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Result - Remark
Verdict
Page 12 of 48
EN 60065
Clause
14.3.5.2
Requirement – Test
Result - Remark
Verdict
Coil formers and partition walls > 0,4 mm
The bobbin: > 0.4mm
thickness.
P
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Windings of Class II
construction used.
N
Winding wires connected to protective earth have
adequate current-carrying capacity
N
High voltage components
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as Not applicable
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
N
14.5
Protective devices
P
14.4
Protective devices used within their ratings
14.5.1.1
14.5.1.2
Mains fuse, F01
P
External clearances and creepage distances meet Certified protective devices
requirement of clause 13 for the voltage across the applied. See List of Critical
device when opened
components.
P
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the
submission
N
a) Thermal links separately approved
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
Fuse is approved according to
IEC 60127. See List of critical
components.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ...: Correct marking applied close
to the fuse:
F01 T2AL, 250Vac
P
14.5.2.3
Not possible to connect fuses in parallel ................: No possible to connect fuses in
parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
14.5.4
No such component
N
PTC-S devices (15 W) category V-1 or better
N
Circuit protectors have adequate breaking capacity
and their position is correctly marked
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 13 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.6
Switches
VDE approved.
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations normal pollution suitability
resistance to heat and fire level 3 and V-0
compliance with annex G, G.1.1
N
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
No such components
Socket outlet current marking correct
14.7
Safety interlocks
N
No safety interlock
N
Safety interlocks to 2.8 of IEC 60950
14.8
Voltage setting devices
N
N
No voltage setting devices
Voltage setting device not likely to be changed
accidentally
N
N
14.9
Motors
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N
14.10
Batteries
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
No such components
No battery used
N
N
Page 14 of 48
EN 60065
Clause
Requirement – Test
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
N
14.10.3
Recharging currents and times within
manufacturers limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
N
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11
Optocouplers
14.12
Result - Remark
Verdict
Opto-coupler (IC2) is approval
component, see list of critical
components.
P
Optocouplers comply with Cl. 8
P
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
P
Surge suppression varistors
No such component used.
N
Comply with IEC 61051-2
N
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
N
15
TERMINALS
P
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
15.1.2
Connectors for antenna, earth, audio, video or data:
See appended table 14.2
P
P
No risk of insertion in mains socket-outlets
Signal input and output
connectors are so designed
that plug inserting into mains
socket-outlets is unlikely occur.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
No risk.
P
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socketoutlets
N
15.2
Provision for protective earthing
P
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
P
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 15 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
P
Protective earth conductors correctly coloured
P
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
P
Protective earth terminal resistant to corrosion
P
Earth resistance test: < 0,1 Ω at 25 A ...................: 0.045Ω
P
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
P
15.3.1
Adequate terminals for connection of permanent
wiring
P
15.3.2
Reliable connection of non-detachable cords:
P
Not soldered to conductors of a printed circuit
board
P
Adequate clearances and creepage distances
between connections should a wire break away
P
Wire secured by additional means to the conductor
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
P
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
P
Clamping of conductor and insulation if not
soldered or held by screws
P
15.3.5
Terminals allow connection of appropriate crosssectional area of conductors, for the rated current
of the equipment
P
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
P
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
P
Terminals designed to avoid conductor slipping out
when tightened or loosened
P
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
P
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
P
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 16 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Terminals located and shielded: test with 8 mm
strand
P
15.4
Devices forming a part of the mains plug
No plug-in equipment
15.4.1
No undue strain on mains socket-outlets
N
15.4.2
Device complies with standard for dimensions of
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
N
16
EXTERNAL FLEXIBLE CORDS
External flexible cord is tested with end products.
N
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................:
N
Non-detachable cords for Class I have
green/yellow core for protective earth
N
16.2
Mains cords conductors have adequate crosssectional area for rated current consumption of the
equipment
N
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
Not applicable
N
N
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
N
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N
16.5
Adequate strain relief on external flexible cords
N
Not possible to push cord back into equipment
N
Strain relief device unlikely to damage flexible cord
N
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
N
16.6
Apertures for external flexible cord: no risk of
Detachable cord used
damage to the cord during assembly or movement
in use
N
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Not transportable musical
instrument
Page 17 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
Not transportable musical
instrument
N
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
P
17.1
Torque test to table 20:
P
- screws into metal: 5 times
See appended table 17.1.
P
- screws into non-metallic material: 10 times
See appended table 17.1.
P
17.2
Correct introduction into female threads in nonmetallic material
N
17.3
Cover fixing screws: captive
P
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
No hazard.
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No such construction
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
No such construction
N
17.8
Fixing devices for detachable legs or stands
provided
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
N
Picture tube separately approved to IEC 61965:
N
P
Checked and internal
connectors are fixed well
No picture tube
P
Picture tube separately approved to 18.1 ...............
N
Picture tubes > 16 cm intrinsically protected
N
Non-intrinsically protected tubes > 16 cm used with
protective screen
N
18.2
Intrinsically protected tubes: tests on 12 samples
N
18.2.1
Samples subject to ageing: 6
N
18.2.2
Samples subject to implosion test: 6
N
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
N
18.1
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 18 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
18.3
Non-intrinsically protected tubes tested to 18.3
N
19
STABILITY AND MECHANICAL HAZARDS
P
Mass of the equipment exceeding 7 kg .................: <7kg
N
Apparatus intended to be fastened in place –
suitable instructions
N
19.1
Test on a plane, inclined at 10o to the horizontal
N
19.2
100 N force applied vertically downwards
N
19.3
100N force, or 13% of weight, applied horizontally
to point of least stability
N
19.4
Edges or corners not hazardous
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
N
19.6
Wall or ceiling mountings adequate
N
20
RESISTANCE TO FIRE
P
20.1
Electrical components and mechanical parts
P
Edges or corners are rounded.
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
Resistance to fire is achieved
by a combination of
engineering design, production
methods and by using
materials with low flammability
for internal parts.
P
b) Exemption for small components as defined in
20.1
Considered.
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
No internal wiring working at
voltages> 4 KV.
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
PCB with flammability class V0.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
N
Page 19 of 48
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
The distance between potential
ignition source and
components, parts not covered
by 20.1.1 and 20.1.2, 20.1.3
exceeded the value specified
in table 13.
P
Components and parts as above but shielded from No barrier
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N
20.2
Fire enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
N
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
N
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not Not provided with protection
apply
against splashing water
N
A.10.2.1
Enclosure provides protection against splashing
water
N
A.10.2.2
Humidity treatment carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
N
Complies with IEC 62151 clause 1
N
Open circuit voltage is far less
than 4 kV
Not connected to
telecommunication networks
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 20 of 48
EN 60065
Clause
Requirement – Test
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS
N
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socketoutlets
N
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
N
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
N
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
N
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
N
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
N
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
N
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
---
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
N
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
N
- protecting rim also tested
N
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Result - Remark
Verdict
Page 21 of 48
EN 60065
Clause
Requirement – Test
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
N
5
DE: additional markings required in German language:
N
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
N
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
N
IT: additional markings on the outside of the TV
receiver in Italian language
N
IT: user instructions in Italian language including a
conformity declaration
N
IT: certification number on the back cover
N
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
N
5.1
14
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Result - Remark
Verdict
Page 22 of 48
5.1
P
TABLE: input test (model:19L11)
Un (V)
In (A)
Pn (W)
Verify
1/8 Max. non-clipped power on speakers with VGA mode (from PC).
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
0.377
20.2
The power did not exceed rated value
10%. Rated power 35W.
0.379
20.2
The power did not exceed rated value
10%. Rated power 35W.
0.350
20.1
The power did not exceed rated value
10%. Rated power 35W.
0.352
20.1
The power did not exceed rated value
10%. Rated power 35W.
0.195
20.2
The power did not exceed rated value
10%. Rated power 35W.
0.195
20.2
The power did not exceed rated value
10%. Rated power 35W.
0.182
20.3
The power did not exceed rated value
10%. Rated power 35W.
0.184
20.3
The power did not exceed rated value
10%. Rated power 35W.
1/8 Max. non-clipped power on speakers with HDMI mode (from DVD player)
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
0.371
19.8
The power did not exceed rated value
10%. Rated power 35W.
0.373
19.8
The power did not exceed rated value
10%. Rated power 35W.
0.346
19.7
The power did not exceed rated value
10%. Rated power 35W.
0.347
19.7
The power did not exceed rated value
10%. Rated power 35W.
0.190
19.7
The power did not exceed rated value
10%. Rated power 35W.
0.191
19.8
The power did not exceed rated value
10%. Rated power 35W.
0.180
19.9
The power did not exceed rated value
10%. Rated power 35W.
0.181
19.9
The power did not exceed rated value
10%. Rated power 35W.
1/8 Max. non-clipped power on speakers with AV mode (from Signal Generator)
90V/50Hz
90V/60Hz
100V/50Hz
0.372
19.9
The power did not exceed rated value
10%. Rated power 35W.
0.374
19.9
The power did not exceed rated value
10%. Rated power 35W.
0.374
19.8
The power did not exceed rated value
10%. Rated power 35W.
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 23 of 48
5.1
P
TABLE: input test (model:19L11)
Un (V)
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
In (A)
Pn (W)
Verify
0.374
19.8
The power did not exceed rated value
10%. Rated power 35W.
0.191
19.8
The power did not exceed rated value
10%. Rated power 35W.
0.193
19.9
The power did not exceed rated value
10%. Rated power 35W.
0.181
20.0
The power did not exceed rated value
10%. Rated power 35W.
0.182
20.0
The power did not exceed rated value
10%. Rated power 35W.
supplementary information
Speaker is 8ohm .
5.1
P
TABLE: Input test(model:19L11)
Un (V)
In (A)
Pn (W)
Verify
Max. non-clipped power on speakers with VGA mode (from PC).
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
0.437
24.0
The power did not exceed rated value
10%. Rated power 35W.
0.439
24.0
The power did not exceed rated value
10%. Rated power 35W.
0.402
23.9
The power did not exceed rated value
10%. Rated power 35W.
0.406
23.9
The power did not exceed rated value
10%. Rated power 35W.
0.220
23.8
The power did not exceed rated value
10%. Rated power 35W.
0.221
23.9
The power did not exceed rated value
10%. Rated power 35W.
0.207
23.9
The power did not exceed rated value
10%. Rated power 35W.
0.208
24.0
The power did not exceed rated value
10%. Rated power 35W.
Max. non-clipped power on speakers with HDMI mode (from DVD player)
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
0.402
21.8
The power did not exceed rated value
10%. Rated power 35W.
0.405
21.8
The power did not exceed rated value
10%. Rated power 35W.
0.372
21.7
The power did not exceed rated value
10%. Rated power 35W.
0.372
21.7
The power did not exceed rated value
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 24 of 48
5.1
P
TABLE: Input test(model:19L11)
Un (V)
In (A)
Pn (W)
Verify
10%. Rated power 35W.
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
0.205
21.7
The power did not exceed rated value
10%. Rated power 35W.
0.204
21.7
The power did not exceed rated value
10%. Rated power 35W.
0.193
21.8
The power did not exceed rated value
10%. Rated power 35W.
0.194
21.8
The power did not exceed rated value
10%. Rated power 35W.
Max. non-clipped power on speakers with AV mode (from Signal Generator)
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
0.429
23.4
The power did not exceed rated value
10%. Rated power 35W.
0.432
23.4
The power did not exceed rated value
10%. Rated power 35W.
0.397
23.3
The power did not exceed rated value
10%. Rated power 35W.
0.398
23.4
The power did not exceed rated value
10%. Rated power 35W.
0.217
23.3
The power did not exceed rated value
10%. Rated power 35W.
0.217
23.3
The power did not exceed rated value
10%. Rated power 35W.
0.204
23.4
The power did not exceed rated value
10%. Rated power 35W.
0.205
23.3
The power did not exceed rated value
10%. Rated power 35W.
supplementary information
Speaker is 8ohm .
5.1
P
TABLE: input test (model:23L11)
Un (V)
In (A)
Pn (W)
Verify
1/8 Max. non-clipped power on speakers with VGA mode (from PC).
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
0.499
27.6
The power did not exceed rated value
10%. Rated power 40W.
0.501
27.6
The power did not exceed rated value
10%. Rated power 40W.
0.462
27.5
The power did not exceed rated value
10%. Rated power 40W.
0.464
27.5
The power did not exceed rated value
10%. Rated power 40W.
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 25 of 48
5.1
P
TABLE: input test (model:23L11)
Un (V)
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
In (A)
Pn (W)
Verify
0.251
27.4
The power did not exceed rated value
10%. Rated power 40W.
0.253
27.4
The power did not exceed rated value
10%. Rated power 40W.
0.235
27.5
The power did not exceed rated value
10%. Rated power 40W.
0.236
27.5
The power did not exceed rated value
10%. Rated power 40W.
1/8 Max. non-clipped power on speakers with HDMI mode (from DVD player)
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
0.498
27.6
The power did not exceed rated value
10%. Rated power 40W.
0.501
27.6
The power did not exceed rated value
10%. Rated power 40W.
0.460
27.6
The power did not exceed rated value
10%. Rated power 40W.
0.460
27.7
The power did not exceed rated value
10%. Rated power 40W.
0.249
27.4
The power did not exceed rated value
10%. Rated power 40W.
0.250
27.4
The power did not exceed rated value
10%. Rated power 40W.
0.234
27.6
The power did not exceed rated value
10%. Rated power 40W.
0.235
27.6
The power did not exceed rated value
10%. Rated power 40W.
1/8 Max. non-clipped power on speakers with AV mode (from Signal Generator)
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
0.499
27.6
The power did not exceed rated value
10%. Rated power 40W.
0.500
27.6
The power did not exceed rated value
10%. Rated power 40W.
0.460
27.4
The power did not exceed rated value
10%. Rated power 40W.
0.463
27.5
The power did not exceed rated value
10%. Rated power 40W.
0.252
27.3
The power did not exceed rated value
10%. Rated power 40W.
0.252
27.3
The power did not exceed rated value
10%. Rated power 40W.
0.235
27.5
The power did not exceed rated value
10%. Rated power 40W.
0.236
27.5
The power did not exceed rated value
10%. Rated power 40W.
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 26 of 48
5.1
P
TABLE: input test (model:23L11)
Un (V)
In (A)
Pn (W)
Verify
supplementary information
Speaker is 8ohm .
5.1
P
TABLE: Input test(model:23L11)
Un (V)
In (A)
Pn (W)
Verify
Max. non-clipped power on speakers with VGA mode (from PC).
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
0.558
31.4
The power did not exceed rated value
10%. Rated power 40W.
0.560
31.4
The power did not exceed rated value
10%. Rated power 40W.
0.514
31.2
The power did not exceed rated value
10%. Rated power 40W.
0.515
31.3
The power did not exceed rated value
10%. Rated power 40W.
0.277
30.9
The power did not exceed rated value
10%. Rated power 40W.
0.277
30.9
The power did not exceed rated value
10%. Rated power 40W.
0.259
31.0
The power did not exceed rated value
10%. Rated power 40W.
0.260
31.0
The power did not exceed rated value
10%. Rated power 40W.
Max. non-clipped power on speakers with HDMI mode (from DVD player)
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
0.532
29.7
The power did not exceed rated value
10%. Rated power 40W.
0.534
29.7
The power did not exceed rated value
10%. Rated power 40W.
0.492
29.5
The power did not exceed rated value
10%. Rated power 40W.
0.494
29.5
The power did not exceed rated value
10%. Rated power 40W.
0.267
29.4
The power did not exceed rated value
10%. Rated power 40W.
0.267
29.4
The power did not exceed rated value
10%. Rated power 40W.
0.250
29.5
The power did not exceed rated value
10%. Rated power 40W.
0.250
29.5
The power did not exceed rated value
10%. Rated power 40W.
Max. non-clipped power on speakers with AV mode (from Signal Generator)
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 27 of 48
5.1
P
TABLE: Input test(model:23L11)
Un (V)
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
In (A)
Pn (W)
Verify
0.552
31.1
The power did not exceed rated value
10%. Rated power 40W.
0.554
31.2
The power did not exceed rated value
10%. Rated power 40W.
0.509
31.0
The power did not exceed rated value
10%. Rated power 40W.
0.512
31.0
The power did not exceed rated value
10%. Rated power 40W.
0.275
30.7
The power did not exceed rated value
10%. Rated power 40W.
0.275
30.8
The power did not exceed rated value
10%. Rated power 40W.
0.258
30.9
The power did not exceed rated value
10%. Rated power 40W.
0.258
30.9
The power did not exceed rated value
10%. Rated power 40W.
supplementary information
Speaker is 8ohm .
7.1 Normal Loudspeaker impedance (Ω) ........... 8 x 2
Heating
-Several loudspeaker systems
(19L11)
Marking of loudspeaker terminals On body of speaker
Monitored point:
dT (K)
P
—
—
Limit dT (K)
Vin=90V/60Hz
Vin=264V/50Hz
Power plug
0.6
0.5
40
Power supply cord
4.9
5.4
40
Switch
1.1
1.9
45
Internal power wire
5.5
5.7
40
Connector CON1
6.5
7.2
--
L01 winding
11.6
11.1
80(130-10-40)
CX2 body
8.4
9.9
60(100-40)
L02 winding
11.4
9.9
80(130-10-40)
PCB under DA04
17.3
8.8
90(130-40)
PCB under Q01
17.4
22.9
90(130-40)
E-cap. EC1 body
11.4
10.2
60(105-40)
CY3 body
12.3
13.1
85(125-40)
Transformer T01 coil
27.1
30.5
80(130-10-40)
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 28 of 48
Transformer T01 core
22.2
25.4
80(130-10-40)
PCB under T01
18.5
20.5
90(130-40)
IC2 body
15.3
17.2
60(100-40)
Inside Enclosure near transformer
7.8
8.9
--
Outer Enclosure near transformer
7.1
8.0
55
Panel
6.2
6.9
55
Key press
3.4
4.1
45
Ambient (°C)
23.5
24.1
--
supplementary information:
*) Temperature limits of winding include less 10°C for thermocouple measurement method.
The temperature rise limit is based on max. ambient operating temperature 40°C declared by the client.
Test with the worst case of normal mode.
7.1
Normal
Heating
(23L11)
Loudspeaker impedance (Ω) .......... 8 x 2
Several loudspeaker systems
P
--
—
Marking of loudspeaker terminals On body of speaker
Monitored point:
dT (K)
—
Limit dT (K)
Vin=90V/60Hz
Vin=264V/50Hz
Power plug
1.3
1.1
40
Power supply cord
7.0
6.8
40
Switch
0.9
0.9
45
Internal power wire
2.8
2.3
40
Connector CON1
4.0
3.3
--
L01 winding
11.5
7.1
80(130-10-40)
CX2 body
6.9
6.4
60(100-40)
L02 winding
13.5
7.8
80(130-10-40)
PCB under DA04
16.4
10.1
90(130-40)
PCB under Q01
24.5
26.1
90(130-40)
E-cap. EC1 body
14.6
10.8
60(105-40)
CY3 body
14.7
13.3
85(125-40)
Transformer T01 coil
27.6
29.6
80(130-10-40)
Transformer T01 core
28.3
30.2
80(130-10-40)
PCB under T01
18.3
17.7
90(130-40)
IC2 body
17.4
18.1
60(100-40)
Inside Enclosure near transformer
9.2
9.3
--
Outer Enclosure near transformer
8.1
9.5
55
Panel
6.8
6.6
55
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 29 of 48
Key press
2.8
2.6
45
Ambient (°C)
25.1
24.8
--
supplementary information:
*) Temperature limits of winding include less 10°C for thermocouple measurement method.
The temperature rise limit is based on max. ambient operating temperature 40°C declared by the client.
Test with the worst case of normal mode
7.2
TABLE: softening temperature of thermoplastics
Temperature T of part
P
T – normal conditions (oC)
T – fault conditions (oC)
T softening
(oC)
Primary AC connector CON1
31.3
33.6
>150
Plastic enclosure
34.3
39.8
>150
8.14
Adequate fastening of covers (pull test 50 N
for 10 s)
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
Location
Measured U1
V (peak)
No damage , no loosen
P
P
Measured Measured U2 Limits :
U1
V (peak)
U1 Max 35V (peak)
V (DC)
U1 Max 1.0V (DC)
U2 Max 0.35V (peak)
Mains pole – Plastic enclosure
(copper foil)
2.9
--
0.28
P
Mains pole – Output terminal
(included Antenna terminal)
8.2
--
0.31
P
Supply Board :(speaker s-c, openings, blocked, max-non-clipped)
Mains pole – Plastic enclosure
(copper foil)
2.8
--
0.23
P
Mains pole – Output terminal
(included Antenna terminal)
5.1
--
0.28
P
supplementary information
Vin = 264Vac, 60Hz
The L/N earth leakage current is max. 0.5mA
No other part exceeds 35V peak or 60V dc.
10.2
TABLE: Humidity Test
Humidity treatment 48 h or 120 h :
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
P
The products show no damage
after kept in 30℃, 93% rh
chamber for 48 hours
Page 30 of 48
No
hazards.
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Basic: Unit Mains poles (primary fuse disconnected)
>2
2
Reinforced: Input and Plastic enclosure
>4
4
Reinforced: Input and Output terminals include antenna
>4
4
Reinforced: Primary and secondary of transformer T01
>4
4
Basic: Primary and core of transformer T01
>2
2
Basic: Secondary and core of transformer T01
>2
2
Reinforced: Insulation sheet between primary and secondary
coil of T01
>4
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Basic: Unit Mains poles (primary fuse disconnected)
2120Vdc
No
Reinforced: Input and Plastic enclosure
4240Vdc
No
Reinforced: Input and Output terminals include antenna
4240Vdc
No
Reinforced: Primary and secondary of transformer T01
4240Vdc
No
Basic: Primary and core of transformer T01
2120Vdc
No
Basic: Secondary and core of transformer T01
2120Vdc
No
Reinforced: Insulation sheet between primary and secondary
coil of T01
4240Vdc
No
11.2
component
No.
Speaker
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ..........: 90V or 264V
—
Ambient temperature (oC) ....................................: 25°C
—
fault
S-C
test
voltage
(V)
264
test time fuse
No.
2.0H
fuse
current
(A)
F01
0.223
result
Image display is normal, no hazards.
Recoverable.
Ventilation
openings
speaker
output
block
264
2.0H
F01
0.236
The unit normal operation, no hazards
max.
nonclipped
264
2.0H
F01
0.260
The unit normal operation, no hazards
On Power Supply Board
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 31 of 48
DA01
S-C
264
1S
F01
0
Fuse opened immediately, no hazards
DA02
S-C
264
1S
F01
0
Fuse opened immediately, no hazards
EC1
S-C
264
1S
F01
0
Fuse opened immediately, no hazards
Q01
Pin G to S
S-C
264
10min
F01
0.046
Q01
pin G-D
S-C
264
1S
F01
0
Fuse opened immediately, R112, Q01
damaged, no hazards
Q01
pin D-S
S-C
264
1S
F01
0
Fuse opened immediately, R109, R112,
R108, Q01 damaged, no hazards
R112
S-C
264
10min
F01
0.183
Unit normal operation, no hazards
IC1
pin2-5
S-C
264
10min
F01
0.046
Unit shut down immediately,
recoverable, no hazards
IC1
pin2-3
S-C
264
10min
F01
0.046
Unit shut down immediately,
recoverable, no hazards
IC1
pin4-6
S-C
264
10min
F01
0.045
Unit shut down immediately,
recoverable, no hazards
T01
pin1-2
S-C
264
10min
F01
0.044↔
0.094
Unit shut down immediately,
recoverable, no hazards
T01
pin4-6
S-C
264
10min
F01
0.044↔
0.156
Unit shut down immediately,
recoverable, no hazards
T01
pin7-9
S-C
264
10min
F01
0.290
T01
pin9-11
S-C
264
10min
F01
0.045↔
0.120
D106
S-C
264
10min
F01
0.154
D107
S-C
264
10min
F01
0.045↔
0.120
Unit shut down immediately,
recoverable, no hazards
IC2
pin1-2
S-C
264
10min
F01
0.043↔
0.303
Circuit protected, recoverable, no
hazards
IC2
pin1
O-C
264
10min
F01
0.046
Unit shut down immediately,
recoverable, no hazards
IC2
pin3-4
S-C
264
10min
F01
0.046
Unit shut down immediately,
recoverable, no hazards
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Unit shut down immediately,
recoverable, no hazards
Unit normal operation, no hazards.
Unit shut down immediately,
recoverable, no hazards
Unit normal operation, no hazards.
Page 32 of 48
IC2
pin3
O-C
264
10min
F01
0.046
Unit shut down immediately,
recoverable, no hazards
+5Vdc
GND
to
S-C
264
10min
F01
0.043↔
0.208
Unit shut down immediately,
recoverable, no hazards
+12Vdc
GND
to
S-C
264
10min
F01
0.043↔
0.186
Unit shut down immediately,
recoverable, no hazards
11.2
TABLE: summary of fault condition tests (Model: 19L11)
P
Voltage (V) 0,9 or 1,1 times rated voltage ....... 90V
—
Ambient temperature (oC) ................................. See below
—
Monitored point:
dT (K)
Limit dT (K)
Speaker
S-C
Openings
Blocked
max. nonclipped
Power plug
0.4
0.2
0.5
40
Power supply cord
5.7
7.7
5.8
40
Switch
1.6
2.8
1.8
45
Internal power wire
6.2
7.7
6.3
40
Connector CON1
8.1
9.7
8.2
--
L01 winding
14.6
13.8
14.4
145
CX2 body
10.0
12.8
10.3
60(100-40)
L02 winding
13.6
12.2
13.6
145
PCB under DA04
20.2
15.6
20.3
145
PCB under Q01
21.4
25.8
21.5
145
E-cap. EC1 body
13.5
13.6
13.4
60(105-40)
CY3 body
14.9
16.6
14.9
85(125-40)
Transformer T01 coil
31.6
33.6
31.7
145
Transformer T01 core
26.3
28.5
26.2
145
PCB under T01
21.4
23.6
21.3
145
IC2 body
17.4
20.5
17.7
60(100-40)
9.2
12.8
9.5
--
8.4
12.4
11.6
55
Panel
7.3
8.5
7.4
55
Key press
4.2
6.3
4.3
45
Ambient (°C)
23.5
23.9
23.9
--
Inside Enclosure near
transformer
Outer Enclosure near
transformer
supplementary information:
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 33 of 48
11.2
TABLE: summary of fault condition tests (Model: 19L11)
P
*) Temperature limits of winding include less 10°C for thermocouple measurement method.
The temperature rise limit is based on max. ambient operating temperature 40°C declared by the client.
11.2
TABLE: summary of fault condition tests (Model: 23L11)
P
Voltage (V) 0,9 or 1,1 times rated voltage ....... 90V
—
Ambient temperature (oC) ................................. See below
—
Monitored point:
dT (K)
Limit dT (K)
Speaker
S-C
Openings
Blocked
max. nonclipped
Power plug
1.2
1.1
1.2
40
Power supply cord
7.3
8.3
7.1
40
Switch
0.9
1.2
1.0
45
Internal power wire
2.5
3.0
2.3
40
Connector CON1
4.1
5.5
3.7
--
L01 winding
13.9
14.6
13.4
145
CX2 body
7.7
9.4
7.3
60(100-40)
L02 winding
16.6
16.5
16.1
145
PCB under DA04
18.5
19.0
18.2
145
PCB under Q01
27.7
27.7
27.2
145
E-cap. EC1 body
16.7
17.4
16.2
60(105-40)
CY3 body
16.5
17.9
16.2
85(125-40)
Transformer T01 coil
31.3
32.8
31.7
145
Transformer T01 core
31.8
31.7
31.3
145
PCB under T01
20.5
21.1
20.1
145
IC2 body
19.5
21.3
19.0
60(100-40)
10.3
14.0
10.1
--
10.5
15.5
10.2
55
Panel
8.6
9.7
8.6
55
Key press
2.5
6.4
2.6
45
Ambient (°C)
25.6
25.8
25.8
--
Inside Enclosure near
transformer
Outer Enclosure near
transformer
supplementary information:
*) Temperature limits of winding include less 10°C for thermocouple measurement method.
The temperature rise limit is based on max. ambient operating temperature 40°C declared by the client.
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 34 of 48
12.1.3
P
TABLE: Mechanical strength-impact test
Applied part
Forces
Time
Result
Top Plastic Enclosure
2J
3
No damage
Back Plastic Enclosure
2J
3
No damage
Side Plastic Enclosure
2J
3
No damage
0.5J
3
No damage
Lift , right port
12.1.5
STRESS RELIEF TEST
Part
Test Temperature (℃)
Test Duration
Observation
Whole unit
70
7h
No visible defect
Notes: Test T=(dT+10+Tmax)℃, dT denote temperature rise of plastic enclosure, Tmax denote maximum
ambient temperature 40°C
13.2
Table: working voltage measurement
Location
RMS voltage (V)
P
Peak voltage (V) Comments
T01 Pin1-7
218
368
T01 Pin2-7
218
352
T01 Pin4-7
230
472
T01 Pin6-7
222
384
T01 Pin1-8,9
296
384
T01 Pin2-8,9
218
352
T01 Pin4-8,9
273
480
T01 Pin6-8,9
221
360
T01 Pin1-11,12
218
360
T01 Pin2-11,12
308
360
T01 Pin4-11,12
324
480
T01 Pin6-11,12
296
408
IC2 Pin1-3
228
356
IC2 Pin1-4
227
352
IC2 Pin2-3
226
356
IC2 Pin2-4
225
352
Pri. to sec. of CY3
219
348
EC1 pin2 to CY3 sec.
221
348
Cl.=4.2mm, Cr.=6.8mm
supplementary information:
Remark: Vin=240V 60Hz
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 35 of 48
13.3 - 13.4 TABLE: clearance and creepage distance measurements
clearance cl and creepage
distance dcr at/of:
P
Up
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required
dcr (mm)
dcr
(mm)
Functional: Live – Neutral
(before fuse)
<420
<250
2.0
4.1
2.5
4.1
Basic: Live – Grounding
<420
<250
2.0
9.0
2.5
9.0
Basic: Neutral to Grounding
<420
<250
2.0
6.5
2.5
6.5
Functional: Fuse
<420
<250
2.0
3.3
2.5
3.3
Basic: Primary components
under PCB to metal chassis
<420
<250
2.0
3.5
2.5
3.5
Basic: PCB under CY1 and
CY2
<420
<250
2.0
6.5
2.5
6.5
Reinforced: EC1 pin 2 to IC2
pin1
<420
<250
4.0
6.2
5.0
6.2
Reinforced: Pri. To sec. of IC2
356
228
4.0
7.7
5.0
7.7
Reinforced: Pri. To sec. of CY3
348
219
4.0
7.5
5.0
7.5
Reinforced: EC1 body To sec.
of CY3
348
221
4.0
7.0
5.0
7.0
Reinforced: T01 Pri. To Sec.
324
480
4.2
7.0
6.8
7.0
Basic: T01 Pri. To core
324
480
2.1
2.8
3.4
4.2
Basic: T01 Sec. To core
324
480
2.1
2.8
3.4
4.2
Transformer T01
supplementary information:
T01 core considered as freebody.
14.2
Table: Critical Electric Components
object/part No.
Manufacturer
/trademark
type/model
technical data
standard
mark(s) of
conformity1)
1.Power
Switch
Yueqing Leci
Electronics Co.,Ltd.
RS601D
6(4)A AC 250V
EN 610581:2002
Zhangjiagang
HF-606(TV)-P
Huafeng Electronic
Connector&Compon
ent Co.,Ltd.
AC 250V 50HZ
8/128A
EN 610581:2002
Zhe Jiang Bei Er Jia
Electronic
PS8A
6(4)A AC 250V
EN 610581:2002
Zibo Tungkou
Chemical Co., Ltd.
Cheil Industries Inc.
Chemicals Div.
VH-0816T
ABS, 94V-0
UL 94
VH-0810(+)
ABS, 94V-0
UL 94
VDE
(40017430)
UL
(E258800)
TUV
(150255590
01)
UL
(E128307)
VDE
(40027141)
UL
(E236875)
UL
(E239474)
UL
(E115797)
2. Enclosure
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
P
Page 36 of 48
14.2
Table: Critical Electric Components
object/part No.
Manufacturer
/trademark
type/model
technical data
standard
mark(s) of
conformity1)
Chi Mei Corporation
PA-765(+)
ABS, 94V-0
UL 94
Chi Mei Corporation
PA-766
ABS, 94V-0
UL 94
LG Display Co., Ltd.
L*185***,
L*200***,
L*215***,
L*230***(“*”
can be “0-9” or
“A-Z” or “Blank”
to indicate the
differnt code of
the client or the
different sales
territory)
LT*200****,
LT*230****(“*”
can be “0-9” or
“A-Z” or “Blank”
to indicate the
differnt code of
the client or the
different sales
territory)
M185**-***,
M200**-***,
M215**-*** ,
*230**-*** (“*”
can be “0-9” or
“A-Z” or “Blank”
to indicate the
differnt code of
the client or the
different sales
territory)
CLAA185********,
CLAA200********,
CLAA215********
(“*” can be “0-9”
or “A-Z” or
“Blank” to
indicate the
differnt code of
the client or the
different sales
territory)
18.5 inch
20 inch
21.5 inch
23 inch
UL 60950
UL
(E56070)
UL
(E56070)
UL
(E200909)
20inch,
23 inch
UL 60950
UL
(E164704)
18.5 inch
20 inch
21.5 inch
23 inch
UL 60950
UL
(E207943)
18.5 inch
20 inch
21.5 inch
UL 60950
UL
(E194548)
3. LCD Panel
SAMSUNG
ELECTRONICS CO
LTD
CHIMEI INNOLUX
CORP
STSP
BRANCH
CHUNGHWA
PICTURE
TUBES
LTD
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
P
Page 37 of 48
14.2
Table: Critical Electric Components
object/part No.
Manufacturer
/trademark
type/model
CHIMEI
CORP
4. PCB
5. Fuse
INNOLUX MT185*****,
MT200*****,
MT215*****,
M*230*****(“*”
can be “0-9” or
“A-Z” or “Blank”
to indicate the
differnt code of
the client or the
different sales
territory)
HUIZHOU
XZG-P1
XINGZHIGUANG
TECHNOLOGY CO
LTD
SHENZHEN LONG D
JIANG INDUSTRY
CO LTD
MEIZHOU
KEJIE KJ-2
INTEGRATED
CIRCUIT CO LTD
XIN
FENG
FU FCF-3
CHANG
FA
ELECTRONIC CO
LTD
GOLDTOP
GT-02
CIRCUITS
(HUIZHOU) CO LTD
KINGBOARD
KB-6160
LAMINATES
(MACAO
COMMERCIAL
OFFSHORE) LTD
Boluo
KONKA KK1
Printed Board Co.,
Ltd.
Huizhou Shenghua SH-05, SH-04,
Industrial Co., Ltd.
SH-01
MEI ZHOU LI YU DA LYD-3
CRICUIT
BOARD
Co., Ltd.
Boluo
KONKA KK6
Printed Board Co.,
Ltd.
Dongguan
Dico Dico-01
Circuit Co., Ltd.
Various
Various
COOPER
BUSSMANN INC.
SR-5(HTM)
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
P
technical data
standard
mark(s) of
conformity1)
18.5 inch
20 inch
21.5 inch
23 inch
UL 60950
UL
(E253847)
94V-0,Thick
1.6mm
UL 796
UL
(E246887)
94V-0,Thick
1.6mm
UL 796
UL
(E300052)
94V-0,Thick
1.6mm
UL 796
UL
(E255694)
94V-0,Thick
1.6mm
UL 796
UL
(E232205)
94V-0,Thick
1.6mm
UL 796
UL
(E216098)
94V-0,Thick
1.6mm
UL 796
UL
(E123995)
94V-0,Thick
1.6mm
UL 796
UL
(E211940)
94V-0,Thick
1.6mm
94V-0,Thick
1.6mm
UL 796
UL
(E202404
UL
(E320265)
94V-0,Thick
1.6mm
UL 796
UL
(E211940)
94V-0,Thick
1.6mm
94V-0, Thick
1.6mm
T2A 250V
UL 796
UL
(E205057)
UL
UL 796
UL 796
EN 60127-1, VDE:12205
EN 60127-3 2
Page 38 of 48
14.2
Table: Critical Electric Components
object/part No.
Manufacturer
/trademark
type/model
XC
5TR
Eelectronics(Shen
Zhen) CORP. LTD.
Hollyland Company 30T
Limited
Various
Various
Nanjing
Shiheng
Electronics Co.,Ltd.
THINKING
ELECTRONIC
INDUSTRIAL
CO
LTD
Various
Fuxin Pan Ocean
7. X2
capacitor(CX2) ElectronicLtd.
6. NTC
P
technical data
standard
T2A 250V
EN 60127-1, VDE(40019
EN 60127-3 789)
T2A 250V
MF72-8D11
3A 120/240V
EN 60127-1,
EN 60127-3
EN 60127-1,
EN 60127-3
UL 1434
SCK-083
3A 240V
UL 1434
Various
MPX
3A 240V
0.47μF/275VAC
UL 1434
UL
IEC 60384- VDE:
14
40015756
UL:E232333
IEC 60384- TUV:160120
14
25001
UL:E208107
T2A 250V
Shantou High-new
MPX
Technology
Development Zone
Songtian Enterprise
Co.,Ltd.
Shenzhen Sincerity MKP/MPX
Technology Co.,Ltd.
0.47μF/275VAC
Shenzhen Su Rong MPX
Capacitors Co.,Ltd.
Xiamen
Faratronic MKP62
Co.,Ltd.
0.47μF/275VAC
Various
mark(s) of
conformity1)
Various
Electronic CT7
8.Y2 Capacitor Anshan
Ceramic Co.,Ltd
(CY1,CY2)
Shantou High-new
AC
Technology
Development Zone
Songtian Enterprise
Co.,Ltd.
Xiamen
Wanming HJ
Electronics Co.,ltd
Guangdong
South Y1
Hongming Electronic
Science
and
Technology Co.,Ltd
Various
Various
9. Y1 capacitor Anshan
Electronic CT7
(CY3)
Ceramic Co.,Ltd
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
0.47μF/275VAC
0.47μF/275VAC
0.47μF/275VAC
1000pF 250Vac
1000pF 400Vac
1000pF 400Vac
1000pF 400Vac
1000pF 400Vac
1000pF 250Vac
VDE(40011
830)
VDE
UL
(E241319)
UL
(E138827)
IEC 60384- VDE:
14
40028812
UL:E319615
IEC 60384- VDE:
14
40008924
IEC 60384- VDE:40000
14
358
UL:E186600
IEC 60384- VDE
14
IEC 60384- VDE:40011
14
817
UL:E232980
IEC 60384- VDE:
14
40025748
UL:E208107
IEC 60384- VDE:
14
4000353
UL:E221839
IEC 60384- VDE:11835
14
7
UL:E154899
IEC 60384- VDE
14
IEC 60384- VDE:40011
14
817
UL:E232980
Page 39 of 48
14.2
Table: Critical Electric Components
object/part No.
Manufacturer
/trademark
type/model
Shantou High-new
AC
Technology
Development Zone
Songtian Enterprise
Co.,Ltd.
Xiamen
Wanming HJ
Electronics Co.,ltd
10.Optcoupler(IC2)
11.Line Filter
Inductor (L01)
Wire(L01)
P
technical data
standard
2200pF 400Vac
IEC 60384- VDE:
14
40025748
UL:E208107
2200pF 400Vac
IEC 60384- VDE:
14
4000353
UL:E221839
IEC 60384- VDE:11835
14
7
UL:E154899
Guangdong
South Y1
Hongming Electronic
Science
and
Technology Co.,Ltd
Various
Various
2200pF 400Vac
Sharp Corporation
dti>0.4mm
PC817
2200pF 400Vac
Lite-On Technology LTV-817
Corporation
dti=0.6mm
Bright
Led BPC-817
Electronics Corp.
dti>0.4mm
Everlight Electronics EL817V
Co., Ltd.
dti=0.5mm
Sharp Corporation
dti>0.4mm
PC817
SHENZHEN
KTC 402-****-*****G
Class B
TECHNOLOGY
(“*” can be “0-9”
CO.,LTD
or “A-Z” or
“Blank” to
indicate the
different code of
the client or the
different sales
territory)
Shanghai
Asia 2UEW
130℃
Pacific
Electric
Co.,Ltd.
TAI-I
COPPER 2UEW
130℃
(GUANGZHOU) CO.,
LTD.
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
IEC 6038414
IEC/EN
60950, VDE
0884,
UL
1577
IEC/EN
60950, VDE
0884,
UL
1577
IEC/EN
60950, VDE
0884,
UL
1577
IEC/EN
60950, VDE
0884
IEC/EN
60950, VDE
0884,
UL
1577
IEC
60065:2005
mark(s) of
conformity1)
VDE
VDE
(40008087),
UL
(E64380)
VDE
(40015248),
UL
(E113898)
VDE
(40007240),
UL
(E236324)
VDE
(132249)
VDE
(40008087),
UL
(E64380)
Test
with
appliance
UL94
E214423
UL94
E85640
Page 40 of 48
14.2
Table: Critical Electric Components
object/part No.
Manufacturer
/trademark
type/model
SHENZHEN
KTC 402-****-*****G
TECHNOLOGY
(“*” can be “0-9”
CO.,LTD
or “A-Z” or
“Blank” to
indicate the
different code of
the client or the
different sales
territory)
-Wire(L02)
Shanghai
Asia 2UEW
Pacific
Electric
Co.,Ltd.
TAI-I
COPPER 2UEW
(GUANGZHOU) CO.,
LTD.
13.Transformer SHENZHEN
KTC 401-****-*****G
(T01)
TECHNOLOGY
(“*” can be “0-9”
CO.,LTD
or “A-Z” or
“Blank” to
indicate the
different code of
the client or the
different sales
territory)
-Bobbin(T01)
SUMITOMO
LCP E4008
CHEMICAL CO.,LTD
-WIRE(T01)
GUANGDONG
2UEW
RONSEN SUPER
MICRO-WIRE
CO.,LTD
SHANHAI
ASIA 2UEW
PACIFIC
-TAPE(T01) JINGJIANG JINGYI JY25-A
ADHESIVE
PRODUCT CO.,LTD
12.Line filter
inductor(L02)
P
technical data
standard
mark(s) of
conformity1)
Class B
IEC
Test
with
60065:2005 appliance
130℃
UL94
E214423
130℃
UL94
E85640
Class B/130℃
IEC
Test
with
60065:2005 appliance
130℃
UL94
E54705
130℃
UL94
E164502
130℃
UL94
E214423
130℃
UL94
E246950
1
) an asterisk indicates a mark which assures the agreed level of surveillance
17.1
P
TABLE: Screws and connections test
Type of
tightening
Diameter of nuts
(mm)
Torque (Nm)
Result
10 times
3.9
1.2Nm
No damage
10 times
2.8
0.4Nm
No damage
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 41 of 48
Attachment 1- Circuit Diagram
Power circuit
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 42 of 48
Attachment 2- EUT Photos
Fig1 EUT Front View(Model:22L11A)
Fig2 EUT Front View(Model:19L11A)
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 43 of 48
Model : 23L11
Fig3 EUT Front View
Fig4 EUT Back View
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 44 of 48
Fig5 EUT base view
Fig6 EUT Internal View
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 45 of 48
Fig 7 Power Board Front View
Fig 8 Power Board Back View
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 46 of 48
Fig 9 Main Board Front View
Fig 10 Main Board Back View
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 47 of 48
Fig11
Remote View
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 48 of 48
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement