ACT-IR2000U FIR-USB Adapter User`s Manual

ACT-IR2000U FIR-USB Adapter User`s Manual
ACTiSYS Corp.
USB-IR Dongle Installation Manual
ACT-IR2000U
FIR-USB Adapter
User’s Manual
ACTiSYS Corporation
48511 Warm Springs Blvd, Suite 206
Fremont, CA 94539, USA
Tel: (510)490-8024, Fax: (510)623-7268
E-Mail: [email protected]
Web: www.actisys.com
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
ACTiSYS Corp.
USB-IR Dongle Installation Manual
FCC & VCCI Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1)This device may not cause harmful interference, and (2)this device must accept any
interference received, including interference that may cause undesired operation.
WARNING-FCC Regulations state that any unauthorized changes or modifications to this
equipment not expressly approved by the manufacturer could void the user authority to
operate this equipment
NOTE: This equipment has been tested and found to comply with the limits for Class B
digital device, pursuant to Part 15 of the FCC Rules. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will nor occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
-Increase the separation between the equipment and receiver.
-Reorient or relocate the receiving antenna.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
This equipment is in the 2nd Class category (information equipment to be used in a
residential area there to) and conforms to the standards set by the Voluntary Control Council
For Interference by Data Processing Equipment and Electronic Office Machines aimed at
preventing radio interference in such residential area.
When used near a radio or TV receiver, it may become the cause of radio interference. Read
the instructions for correct handling.
NOTE: Must be used with shielded cable only.
FOR YOU RECORDS.....
For your assistance in reporting this product in case of loss or theft, please record below the
model number and serial which are located on the bottom of the case. Please retain this
information.
Model Number
Serial Number
Date of Purchase
Place of Purchase
All indicated copyrights and trademarks in the following pages are copyrights and
trademarks of their respective corporations.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
2
ACTiSYS Corp.
USB-IR Dongle Installation Manual
TABLE OF CONTENTS
TABLE OF CONTENTS .......................................................................................................................................................... 3
INTRODUCTION ..................................................................................................................................................................... 4
PACKING CHECK LIST ........................................................................................................................................................ 4
SYSTEM REQUIREMENTS................................................................................................................................................... 4
BIOS SETUP ............................................................................................................................................................................. 4
WINDOWS 98 INSTALLATION GUIDE.............................................................................................................................. 5
WINDOWS 98 UN-INSTALLATION GUIDE....................................................................................................................... 8
ADVANCED UNINSTALL PROCEDURE.......................................................................................................................... 11
WINDOWS 2000 INSTALLATION GUIDE ........................................................................................................................ 12
WINDOWS 2000 UN-INSTALLATION GUIDE................................................................................................................. 14
WINDOWS ME INSTALLATION GUIDE ......................................................................................................................... 18
WINDOWS ME UN-INSTALLATION GUIDE .................................................................................................................. 21
WINDOWS XP INSTALLATION GUIDE........................................................................................................................... 25
WINDOWS XP UN-INSTALLATION GUIDE.................................................................................................................... 29
TROUBLE SHOOTING......................................................................................................................................................... 31
SPECIFICATION ................................................................................................................................................................... 32
WARRANTY INFORAMTION ............................................................................................................................................ 34
CONTACT INFORMATION ................................................................................................................................................ 36
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
3
ACTiSYS Corp.
USB-IR Dongle Installation Manual
INTRODUCTION
ACTiSYS IR2000U is an advanced wireless Fast Infrared USB adapter designed to replace the
serial port or FIR controller based FIR/SIR wireless peripheral through the PC USB (Universal
Serial Bus) port. Taking advantage of the true plug-and-play nature and the high bandwidth of
USB, IR2000U offers the easiest conversion of existing wireless to the legacy-free personal
computer platform with the following features:
• Fully compliant to USB specification 1.1 and IrDA specification 1.1
• Full-speed (12 Mbps) USB device operation
• Supports FIR (4Mbps) and all SIR speeds (9.6, 19.2, 38.4, 57.6 and 115.2Kbps).
• Bus-powered device. Obtain power from USB port. No external power supply required.
• Low power consumption in standby mode ( Standby current is less than 0.5 mA
• Not occupy PC's COM or Parallel port and has no complicated hardware port and resource
setting and conflict, such as IO address / IRQ / DMA numbers.
• True PNP (Plug And Play) device. Without re-installing USB driver when re-plugs in.
• Small package size: 2.4"L x 1.4"W x 0.74"H, 2.4 oz (65.0 gr)
PACKING CHECK LIST
When you unpack the package, the following items should be found.
1. ACT-IR2000U.
2. User’s Guide
3. 2 floppy disks. One is for ACT-USB Driver, another is for User’s manual.
SYSTEM REQUIREMENTS
To use ACT-IR2000U, your computer MUST meet the following requirements.
1. Window 98/ME/2000/XP.
2. One unoccupied USB port.
BIOS SETUP
Before you are trying to use this device, You MUST enable your computer USB port in BIOS
Settings.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
4
ACTiSYS Corp.
USB-IR Dongle Installation Manual
WINDOWS 98 INSTALLATION GUIDE
Note: Make sure no hardware or software is occupying or binding the USB port that you intend to use for
ACT-IR2000u. Plugging and unplugging multiple USB devices on the same USB port may cause damage
to your registry and may make your Windows O.S unstable.
Note:
UNPLUG ACT-IR2000U on your computer before you boot your system.
No prior similar IrDA-USB driver software was installed. If yes, please refer to
Un-installation Guide to remove the old driver, before installing this new driver software
1. Boot your system.
2. Go to A: driver
3. Double Click ACTiSYS IR2000U20.exe
4. Click Next>
5. Click Next>
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
5
ACTiSYS Corp.
USB-IR Dongle Installation Manual
6. Click Next>
7. Click Next>
8. Highlight ACT-IR2000UIC from
Manufacturers list, Highlight ACTiSYS
USB IrDA Adapter – Windows 98
9. Click Finish
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
6
ACTiSYS Corp.
USB-IR Dongle Installation Manual
10. Click Finish, reboot your system.
11. Plug ACT-IR2000U on USB port when your computer start.
12. After booting your system, enable infrared
communication.
After a few seconds, the light on the top of ACT-IR2000U begins to blink every three seconds.
The device has been successfully installed on you computer.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
7
ACTiSYS Corp.
USB-IR Dongle Installation Manual
WINDOWS 98 UN-INSTALLATION GUIDE
Warning: You must be very careful if you decide to remove system files or delete
registration keys. If you have removed the wrong components, your Windows system
may have to be reinstalled and ACTiSYS will not be liable for your fault. If you are not a
PC advanced user, you should choose only the Simple Uninstall Procedure. It will leave
some components in your system but harmless.
Note: Make sure of PLUGGING ACT-IR2000U on your computer before you uninstall the
device.
1. Boot your system
2. Go to the Control Panel
3. Double Click Add/Remove program icon
4. Choose the ACT USB IrDA Adapter, Click
Add/Remove button.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
8
ACTiSYS Corp.
USB-IR Dongle Installation Manual
5. Click Yes
6. Click OK
7. Double click System icon
8. Go to Device Manager, highlight Infrared
Communication Device, Click Remove
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
9
ACTiSYS Corp.
USB-IR Dongle Installation Manual
9. Click OK
10. Highlight IRXpress USB IrDA Adapter,
then Click Remove
11. Highlight ACT USB Irda Adapter –
Windows Me, then Click Remove
12. Click Yes
13. Unplug ACT-IR2000U when your system reboots. So far, you have successfully uninstalled
the device.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
10
ACTiSYS Corp.
USB-IR Dongle Installation Manual
ADVANCED UNINSTALL PROCEDURE
1.
2.
3.
4.
Remove drivers kcIrUSB.sys and kcIrNet.sys files under c:\windows\system32\drivers\
Remove kcirnet.inf, precompiled information files DRVDATA.BIN and DRVIDX.BIN under
c:\windows\inf
Remove copies of inf files ACTiSYS Corp. KCIRUSB.INF and ACTiSYS Corp.
KCIRNET.INF under c:\windows\inf\other\
Delete registration key:
Run Start | Run…| regedit
Find HKEY_LOCAL_MACHINE\Enum\USB\VID_09C4&PID_0011 and delete it.
NOTE: You may have to uninstall all components of previous version of IR2000U, such as
Infrared and Network components, windows registration, driver and information files, completely
before beginning installation of new version IR2000U.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
11
ACTiSYS Corp.
USB-IR Dongle Installation Manual
WINDOWS 2000 INSTALLATION GUIDE
Note:
The Win2000 driver of IR2000U works only under the release build 2195 or above.
Note: Make sure no hardware or software is occupying or binding the USB port that you intend to use
for ACT-IR2000u. Plugging and unplugging multiple USB devices on the same USB port may cause
damage to your registry and may make your Windows O.S unstable.
Note: Registry files in Windows 2000 cannot be modified or deleted. If the above precautions are not
taken and the installation guide is not followed step by step it may require you to re-install Windows2000
again in many cases.
Note: UNPLUG ACT-IR2000U on your computer before you boot your system. No prior similar
IrDA-USB driver software was installed. If yes, please refer to Un-installation Guide to remove
the old driver, before installing this new driver software
1. Boot your system.
2. Go to A: driver
3. Double click ACTiSYS IR2000U20.exe
4. Click Next>
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
12
ACTiSYS Corp.
USB-IR Dongle Installation Manual
5. Click Next>
6. Click Next>
7. Click Finish
8. Plug ACT-IR2000U on USB port when your computer start.
After a few seconds, the light on the top of ACT-IR2000U begins to blink every three seconds.
The device has been successfully installed on you computer.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
13
ACTiSYS Corp.
USB-IR Dongle Installation Manual
WINDOWS 2000 UN-INSTALLATION GUIDE
Note: Make sure of PLUGGING ACT-IR2000U on your computer before you uninstall the
device.
1. Boot your system
2. Go to Control Panel
3. Double click Add/Remove Program icon.
4. Highlight ACT USB Irda Adapter, Click
Change/Remove
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
14
ACTiSYS Corp.
USB-IR Dongle Installation Manual
5. Click Yes
6. Click Yes To All
7. Click OK
8. Click Close
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
15
ACTiSYS Corp.
USB-IR Dongle Installation Manual
9. Double click System icon
10. Click Device Manager
11. Highlight IRXpress USB Infrared Adapter
in Infrared devices, then Uninstall
12. Click OK
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
16
ACTiSYS Corp.
USB-IR Dongle Installation Manual
13. Highlight IRXpress USB IrDA Adapter in
Universal Serial Bus controller, then
Uninstall
14. Click OK, then close the Device Manager
15. Unplug ACT-IR2000U when your system reboots. So far, you have successfully uninstalled
the device.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
17
ACTiSYS Corp.
USB-IR Dongle Installation Manual
WINDOWS ME INSTALLATION GUIDE
Note:
The Win2000 driver of IR2000U works only under the release build 9.30.2000 or above.
Note: Make sure no hardware or software is occupying or binding the USB port that you intend to use
for ACT-IR2000u. Plugging and unplugging multiple USB devices on the same USB port may cause
damage to your registry and may make your Windows O.S unstable.
Note: UNPLUG ACT-IR2000U on your computer before you boot your system. No prior similar
IrDA-USB driver software was installed. If yes, please refer to Un-installation Guide to remove
the old driver, before installing this new driver software
1. Boot your system.
2. Go to A: driver
3. Double click ACTiSYS IR2000U20.exe
4. Click Next>
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
18
ACTiSYS Corp.
USB-IR Dongle Installation Manual
5. Click Next>
6. Click Next>
7. Click Next>
8. Highlight ACT-IR2000UIC from
Manufacturers list and ACT USB Irda
Adapter – Windows Me from Infrared
devices list, then click OK
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
19
ACTiSYS Corp.
USB-IR Dongle Installation Manual
9. Click Finish
10. Click Finish
11. Plug ACT-IR2000U on USB port when your computer start.
After a few seconds, the light on the top of ACT-IR2000U begins to blink every three seconds.
The device has been successfully installed on you computer.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
20
ACTiSYS Corp.
USB-IR Dongle Installation Manual
WINDOWS ME UN-INSTALLATION GUIDE
Note: Make sure of PLUGGING ACT-IR2000U on your computer before you uninstall the
device.
1. Boot your system
2. Go to Control Panel
3. Double click Add/Remove program icon
4. Highlight ACT USB Irda Adapter, then
click Add/Remove.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
21
ACTiSYS Corp.
USB-IR Dongle Installation Manual
5. Click Yes
6. Click Yes To All
7. Click OK
8. Click OK
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
22
ACTiSYS Corp.
USB-IR Dongle Installation Manual
9. Double click System icon
10. Go to Device Manager, highlight Infrared
Communication Device, click Remove
11. Click No
12. Highlight IRXpress USB IrDA Adapter,
then Remove
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
23
ACTiSYS Corp.
USB-IR Dongle Installation Manual
13. Highlight ACT USB Irda Adapter –
Windows Me, then Remove
14. Click Yes
15. Unplug ACT-IR2000U when your system reboots. So far, you have successfully uninstalled
the device.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
24
ACTiSYS Corp.
USB-IR Dongle Installation Manual
WINDOWS XP INSTALLATION GUIDE
Note: Make sure no hardware or software is occupying or binding the USB port that you intend to use for
ACT-IR2000u. Plugging and unplugging multiple USB devices on the same USB port may cause damage
to your registry and may make your Windows O.S unstable.
Note: UNPLUG ACT-IR2000U on your computer before you boot your system. No prior similar
IrDA-USB driver software was installed. If yes, please refer to Un-installation Guide to remove
the old driver, before installing this new driver software
1. Do not connect ACT-IR2000U to your computer while booting the system.
2. Double-click Actisys IR2000U20.exe.
3. Wait…
4. Click Next> on the following window.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
25
ACTiSYS Corp.
USB-IR Dongle Installation Manual
5. Click Next>
6. Click Next>
7. Click Continue Anyway
8. Choose Yes, I want to restart my
computer now, then click Finish
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
26
ACTiSYS Corp.
USB-IR Dongle Installation Manual
9. Restart your computer and plug ACT
IR2000U into your computer. Your
computer will pop up to a window. Choose
Install the software automatically, then
click Next>.
10. Wait…
11. System will install driver for ActIsys
IR2000U
12. Click Continue Anyway
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
27
ACTiSYS Corp.
USB-IR Dongle Installation Manual
13. Click Finish
14. You have successfully installed the device.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
28
ACTiSYS Corp.
USB-IR Dongle Installation Manual
WINDOWS XP UN-INSTALLATION GUIDE
1. Go to Control Panel
2. Double Click Add or Remove Programs
icon.
3. Highlight KC ACTiSYS IR2000U then click
Change/Remove
4. Click Yes
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
29
ACTiSYS Corp.
USB-IR Dongle Installation Manual
5. Click Yes To All.
6. Click Yes.
7. Click OK. You have successfully
uninstalled the device from your system.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
30
ACTiSYS Corp.
USB-IR Dongle Installation Manual
TROUBLE SHOOTING
For help on general and miscellaneous problems you may be experiencing with your printing, refer to the
following pages for possible solutions. Look up your problem and try the solution.
SYMPTOM
Can not establish link
(General)
PROBLEM
Solution
1. The two IR devices are 1.
not aligned properly.
2. Distance is too near or 2.
far.
3. Device is inactivated
3.
4. BIOS setting incorrect
5. Installation is not correct. 4.
Properly align them
again
Move one device to a
proper distance.
Enable the device by IR
monitor.
Correct the BIOS
Setting.
5. Refer to un-installation
guide to remove the
device, then install
again.
File Transfer between
The infrared
IR-equipped PDA and
communication is
ACT-IR device-attached
interfered. For example,
host computer stops before something blocks out the
finishing up and an error
infrared beam or the burst
message appears.
of string light source, etc.
Check to find out the source
of interference and
eliminate it before trying
again.
The device work well
Improper unplug and plug
before. But after I unplug it procedure
then plug, it does not work
again.
Before you unplug it, you
should disable the device.
And enable the device after
you plug it into your
computer
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
31
ACTiSYS Corp.
USB-IR Dongle Installation Manual
SPECIFICATION
•
•
•
Product Name: ACT-IR2000U FIR-USB Adapter
Compatibility: Fully compliant to USB specification 1.1 and IrDA specification 1.1
Communication speed and Distance:
IrDA-1.0 (9.6, 19.2, 38.4, 57.6, 115.2Kbps): 3-100cm;
IrDA-1.1 (4Mbps): 3--100cm;
•
•
Connection: Standard USB connector with 4-ft USB cable
Power Source:
Obtain power from USB port. No external power supply required.
•
Power Consumption:
Active current < 400 mA), standby current: < 0.5 mA
•
•
•
•
Dimension: 61mm(L) X 35mm(W) X 18mm(H), 2.4"(L) X 1.4"(W) X 0.7"(H)
2.4 oz (65.0 gr)
Weight:
Operating Temperature: 0° C TO 40° C
Storage Temperature -20° C TO 85° C
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
32
ACTiSYS Corp.
USB-IR Dongle Installation Manual
PRECAUTIONS
To ensure trouble-free operation, please observe the following precautions:
Optical communications are easily affected by external light sources, weak batteries,
transfer distance, transfer angle, etc. Any of these conditions may cause a data transfer
failure, incomplete, missing or incorrect data. Make sure that the wireless interface is
away from direct sunlight and other strong light source.
zDo not terminate arbitrarily during file transfer process between DUT and computers
until finished. Otherwise DUT internal data integrity may be damaged, which is due
to the violation of DUT’s.
zDo not expose the unit to moisture, as this will damage the internal circuitry.
zDo not expose the unit to extreme temperatures. It should not be placed in direct sunlight or
in a closed vehicle, neither should it be placed near heaters nor other heat sources.
zDo not store the unit in a humid or dusty place.
zUse a soft, dry cloth to clean the unit. Do not use a wet cloth or any solvent.
zDo not drop the unit or handle the unit carelessly.
CAUTION:
zNever touch the pins of computer connection terminal. The internal circuits can be
damaged by a static Electricity discharge. If this device requires any servicing, use only an
ACTiSYS service dealer, an ACTiSYS approved service facility, or an ACTiSYS repair
service.
zWhen exchanging data with host computer, be sure the appropriate serial communication
port is available and is not in conflict with other peripheral device or software.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
33
ACTiSYS Corp.
USB-IR Dongle Installation Manual
WARRANTY INFORMATION
THE FOLLOWING WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE
OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
ACTiSYS Corporation warrants to the first consumer purchaser, for a period of one year from the date of
purchase, that this wireless interface (“the Product”) will be free from defective workmanship and
materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or
part thereof at no charge to the purchaser for parts or for labor.
This warranty does not apply to any appearance items of the Product, any consumable items such as
paper, ink ribbon, or batteries supplied with the Product, or to any equipment or any hardware, software,
firmware, or peripheral other than the Product. This warranty does not apply to any Product the exterior of
which has been damaged or defected, which has been subjected to misuse, abnormal service or handling,
or which has been altered or modified in design, construction or interfacing. Tampering With Label
Voids Warranty.
In order to enforce the rights under this limited warranty, the purchaser should mail, ship, or carry the
Product, together with proof of purchase, to ACTiSYS.
The limited warranty described above is in addition to whatever implied warranties may be granted to
purchasers by law. To the extent permitted by applicable law, ALL IMPLIED WARRANTIES INCLUDING
THE WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR USE ARE LIMITED TO A PERIOD
OF ONE YEAR FROM THE DATE OF PURCHASE. Some states do not allow limitations on how long an
implied warranty lasts, so the above limitation may not apply to you.
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other
than those described above, or to extend the duration of any warranties beyond the time period described
above on behalf of ACTiSYS Corporation.
The warranties described above shall be the sole and exclusive remedy available to the purchaser.
Correction of defects, in the manner and for the period of time described above, shall constitute full
satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event
shall ACTiSYS Corporation be liable, or in any way responsible, for any damages or defects in the
Product which were caused by repairs or attempted repairs performed by anyone other than ACTiSYS
technician. Nor shall ACTiSYS Corporation be liable or in any way responsible for any incidental or
consequential economic or property damage. Some states do not allow the exclusion of incidental or
consequential damages, so the above exclusion may not apply for you.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
34
ACTiSYS Corp.
USB-IR Dongle Installation Manual
ACTiSYS Corporation warrants to the first consumer purchaser, for a period of 1 year from the
date of purchase, that this wireless interface (The Product? Will be free from defective
workmanship and materials, and agrees that it will, at its option, either repair the defect or
replace the defective Product or part thereof at no charge to the purchaser for parts or for labor.
This warranty does not apply to any appearance items of the Product, any consumable items
such as paper, ink ribbon, or batteries supplied with the Product, or to any equipment or any
hardware, software, firmware, or peripheral other than the Product. This warranty does not apply
to any Product the exterior of which has been damaged or defected, which has been subjected to
misuse, abnormal service or handling, or which has been altered or modified in design,
construction or interfacing. Tampering With Label Voids Warranty.
In order to enforce the rights under this limited warranty, the purchaser should mail, ship, or carry
the Product, together with proof of purchase, to ACTiSYS .
The limited warranty described above is in addition to whatever implied warranties may be
granted to purchasers by law. To the extent permitted by applicable law, ALL IMPLIED
WARRANTIES INCLUDING THE WARRANTIES OF MERCHANT ABILITY AND FITNESS
FOR USE ARE LIMITED TO A PERIOD OF 1 YEAR FROM THE DATE OF PURCHASE. Some
states do not allow limitations on how long an implied warranty lasts, so the above limitation may
not apply to you.
Neither the sales personnel of the seller nor any other person is authorized to make any
warranties other than those described above, or to extend the duration of any warranties beyond
the time period described above on behalf of ACTiSYS Corporation.
The warranties described above shall be the sole and exclusive remedy available to the
purchaser. Correction of defects, in the manner and for the period of time described above, shall
constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or
otherwise. In no event shall ACTiSYS Corporation be liable or in any way responsible, for any
damages or defects in the Product which were caused by repairs or attempted repairs performed
by anyone other than ACTiSYS technician. Nor shall ACTiSYS Corporation be liable or in any
way responsible for any incidental or consequential economic or property damage. Some states
do not allow the exclusion of incidental or consequential damages, so the above exclusion may
not apply to you.
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
35
ACTiSYS Corp.
USB-IR Dongle Installation Manual
CONTACT INFORMATION
ACTiSYS Corporation.
48511 Warm Springs Blvd, Suite 206
Fremont, CA 94539, USA
TEL: (510) 490-8024, FAX: (510) 623-7268
E-Mail: [email protected]
Web: www.actisys.com
Release V1.43
ACTiSYS Corporation 2001 All Rights Reserved
36