"user manual"

Add to my manuals
74 Pages

advertisement

Spec Sheet

Cisco UCS C220 M4

High-Density Rack Server

(Small Form Factor Disk

Drive Model)

C

ISCO

S

YSTEMS

170 W

EST

T

ASMAN

D

R

S

AN

J

OSE

, CA, 95134

WWW

.

CISCO

.

COM

P

UBLICATION

H

ISTORY

R

EV

A.5

O

CTOBER

15, 2014

OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6

CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

STEP 2 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

STEP 3 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

STEP 4 SELECT RAID CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . . . . . . . . . . . . . 23

STEP 6 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 29

STEP 8 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

STEP 9 SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

STEP 10 ORDER RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . . . . . . . . 37

STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . 38

STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . 39

STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 40

STEP 14 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

STEP 15 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

DIMM Population Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Recommended Memory Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Additional DIMM Populations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

RAID Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

RAID Option ROM (OPROM) Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

Embedded SATA RAID: Two SATA Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Serial Port Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

Upgrade and Servicing-Related Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Adding an Additional CPU (with CPU heat sink) . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Motherboard Lithium Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Thermal Grease (with syringe applicator) for CPU to Heatsink Seal . . . . . . . . . . . . . . 64

Air Baffle Replacement Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

CPU Heat Sink Cleaning Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

KVM CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Motherboard USB and SD Ports, and RAID Card Backup Location . . . . . . . . . . . . . . . . . . . . 70

TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

Compliance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

2

Cisco UCS C220 M4 High-Density Rack Server Small Form Factor Disk Drive Model)

OVERVIEW

OVERVIEW

The Cisco® UCS C220 M4 SFF rack server is the newest 2-socket, 1U rack server from Cisco, designed for both performance and expandability over a wide range of storage-intensive infrastructure workloads from big data to collaboration.

The enterprise-class UCS C220 M4 SFF server extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U form factor with the addition of the Intel Xeon E5-2600 v3 series processor family that deliver significant performance and efficiency gains. In addition, the UCS C220 M4 SFF server provides 24

DIMM slots, up to 8 drives and 2 x 1 GbE LAN-on-motherboard (LOM) ports delivering outstanding levels of density and performance in a compact 1U package.

The C220 M4 SFF server includes a modular LAN on motherboard (mLOM) slot for installation of a Cisco

Virtual Interface Card (VIC) or third-party network interface card (NIC) without consuming a PCI slot in addition to 2 x 1 GbE embedded (on the motherboard). These features combine to provide outstanding levels of internal memory and storage expandability along with exceptional performance.

The Cisco UCS C220 M4 SFF server can be used standalone, or as part of the Cisco Unified Computing

System, which unifies computing, networking, management, virtualization, and storage access into a single integrated architecture enabling end-to-end server visibility, management, and control in both bare metal and virtualized environments.

Figure 1 Cisco UCS C220 M4 High-Density SFF Rack Server

Front View

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

3

DETAILED VIEWS

DETAILED VIEWS

Chassis Front View

Figure 2

shows the front view of the Cisco UCS C220 M4 High-Density SFF Rack Server.

Figure 2 Chassis Front View

4 5

6

7 9

8 10

2

HDD 02

HDD 05

HDD 03

HDD 06

3

HDD 07 HDD 08

HDD 01

HDD 04

1 11

3

4

1

2

5

Drives (up to eight 2.5-inch drives)

Pull-out asset tag

Operations panel buttons and LEDs

Power button/Power status LED

Unit identification button/LED

7

8

9

10

11

Fan status LED

Temperature status LED

Power supply status LED

Network link activity LED

KVM connector (used with KVM cable that provides two USB 2.0, one VGA, and one serial connector) 1

6

System status LED

Notes . . .

1. For more information about the KVM cable connection, see

KVM CABLE, page 69

4 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

DETAILED VIEWS

Chassis Rear View

Figure 3

shows the external features of the rear panel.

Figure 3 Chassis Rear View

1 2

PCIe 01 PCIe 02

PSU 01 PSU 02 mLOM

3 4

5

6 7 8 9 10 11

1

2

PCIe riser 1/slot 1

PCIe riser 2/slot 2

7

8

Serial port (RJ-45 connector) 1

Two embedded (on the motherboard) Intel i350 GbE Ethernet controller ports

(LAN1, LAN2)

VGA video port (DB-15)

3

4

5

6

Modular LAN-on-motherboard (mLOM) card slot

Grounding-lug hole (for DC power supplies)

USB 3.0 ports (two)

1-Gb Ethernet dedicated management port

9

10

11

Rear unit identification button/LED

Power supplies (up to two, redundant as 1+1)

Notes . . .

1. For details of the serial port pinout, see

Embedded SATA RAID: Two SATA Controllers, page 59

.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

5

BASE SERVER STANDARD CAPABILITIES and FEATURES

BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1

lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory)

are provided in

CONFIGURING the SERVER, page 9

.

Table 1 Capabilities and Features

Capability/Feature

Chassis

CPU

Chipset

Memory

Multi-bit Error

Protection

Embedded NIC

Expansion slots

Internal storage devices

Cisco Flexible Flash drives

Description

One rack unit (1RU) chassis

One or two Intel® Xeon E5-2600 v3 series processor family CPUs

Intel® C610 series chipset

24 slots for registered DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)

This server supports multi-bit error protection.

Two embedded (on the motherboard) Intel i350 GbE ports, supporting the following:

Pre-Execution Boot (PXE boot) iSCSI boot

Checksum and segmentation offload

NIC teaming

Riser 1:

• One full-height profile, 3/4-length slot with x24 connector and x16 lane

Riser 2:

• One half-height profile, half-length slot with x24 connector and x16 lane

Dedicated Cisco 12G SAS Modular RAID controller slot

• An internal slot is reserved for the 12G SAS Modular RAID controller card.

Drives are installed into front-panel drive bays that provide hot-pluggable access.

• Small Form Factor (SFF) drives. Up to eight 2.5-inch SAS or SATA hot-swappable hard disk drives (HDDs) or solid state drives (SSDs).

The server also contains one internal USB 2.0 port on the motherboard that you can use with a USB thumb drive for additional storage

UCS Storage Accelerators are also available. These PCIe flash storage devices provide independent high-speed storage.

The server supports up to two internal 32 GB or two internal 64 GB Cisco

Flexible Flash drives (SD cards).

6 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 Capabilities and Features (continued)

Capability/Feature

Video

Storage controller

Description

The Baseboard Management Controller provides video:

Matrox G200e video controller

Integrated 2D graphics core with hardware acceleration

Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at

60 Hz

24-bit color depth for all resolutions less than 1600x1200

256 MB video memory

Embedded Software RAID (6 Gbps)

• Embedded SATA-only RAID controller, supporting up to eight

SATA-only drives (RAID 0, 1), or

• Embedded Software RAID 5 key upgrade, supporting up to eight

SATA-only drives (RAID 0, 1, 5, 10)

Cisco 12G SAS Modular RAID controller card, supporting up to eight drives, which plugs into a dedicated RAID controller slot. This card can be purchased alone, or along with an onboard Flash-Backed Write Cache

(FBWC) upgrade option, as shown in the table below

WoL

Front Panel

RAID Card Version

UCSC-MRAID12G

1

UCSC-MRAID12G-1GB 2

UCSC-MRAID12G-2GB

2

UCSC-MRAID12G-4GB 2

Notes . . .

1. Base RAID controller card

2. FBWC option

Supported RAID Levels

JBOD, 0, 1, 10

JBOD, 0, 1, 5, 6, 10, 50, 60

JBOD, 0, 1, 5, 6, 10, 50, 60

JBOD, 0, 1, 5, 6, 10, 50, 60

Onboard FBWC

None

1 GB

2 GB

4 GB

Cisco 9300-8E 12G SAS PCIe external drive controller

• Cisco 12G SAS 9300-8e HBA with 8 external ports. SAS 3.0 compliant.

Provides eight external SAS ports. There is no cache or cache power backup.

The 1-Gb Base-T Ethernet LAN ports support the wake-on-LAN (WoL) standard.

A front panel controller provides status indications and control buttons

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

7

BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 Capabilities and Features (continued)

Capability/Feature

Modular LAN on

Motherboard (mLOM) slot

Description

The mLOM slot can flexibly accommodate the following cards:

Cisco Virtual Interface Cards (VIC)

Quad Port Intel i350 1GbE RJ45 Network Interface Card (NIC)

NOTE: The four Intel i350 ports are provided on an optional card that plugs into the mLOM slot, and are separate from the two embedded (on the motherboard) LAN ports.

Interfaces

Power subsystem

ACPI

Fans

Integrated management processor

Rear panel

• One DB15 VGA connector

• One RJ45 serial port connector

• Two USB 3.0 port connectors

• One RJ-45 10/100/1000 Ethernet management port, using Cisco

Integrated Management Controller (CIMC) firmware

• Two Intel i350 embedded (on the motherboard) GbE LOM ports

• One flexible modular LAN on motherboard (mLOM) slot that can accommodate various interface cards

Front panel

• One KVM console connector (supplies two USB 2.0 connectors, one

VGA DB15 connector, and one serial port (RS232) RJ45 connector)

Various PCIe card ports (dependent on which cards are installed)

• Virtual Interface Card (VIC) ports

• Converged Network Adapter (CNA) ports

• Network Interface Card (NIC) ports

• Host Bus Adapter (HBA) ports

Up to two 770 W (AC) hot swappable power supplies. One is mandatory; one more can be added for 1 + 1 redundancy.

This server supports the advanced configuration and power interface (ACPI)

4.0 standard.

Chassis:

Six hot-swappable fans for front-to-rear cooling

BMC running Cisco Integrated Management Controller (CIMC) firmware.

Depending on your CIMC settings, the CIMC can be accessed through the

1-GbE dedicated management port, the 1-GbE LOM ports, or a Cisco virtual interface card (VIC).

8 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

CONFIGURING the SERVER

Follow these steps to configure the Cisco UCS C220 M4 High-Density SFF Rack Server:

STEP 1 VERIFY SERVER SKU, page 10

STEP 2 SELECT CPU(s), page 11

STEP 3 SELECT MEMORY, page 13

STEP 4 SELECT RAID CONFIGURATION, page 18

STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 23

STEP 6 SELECT PCIe OPTION CARD(s), page 26

STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 29

STEP 8 ORDER POWER SUPPLY, page 33

STEP 9 SELECT AC POWER CORD(s), page 34

STEP 10 ORDER RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 37

STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL), page 38

STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL), page 39

STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 40

STEP 14 SELECT OPERATING SYSTEM MEDIA KIT, page 43

STEP 15 SELECT SERVICE and SUPPORT LEVEL, page 44

OPTIONAL STEP - ORDER RACK(s), page 49

OPTIONAL STEP - ORDER PDU, page 50

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

9

CONFIGURING the SERVER

STEP 1 VERIFY SERVER SKU

Verify the product ID (PID) of the server as shown in

Table 2

.

Table 2 PID of the C220 M4 High-Density SFF Rack Base Server

Product ID (PID)

UCSC-C220-M4S UCS C220 M4 SFF, no CPU, memory, HDD, SSD, power supply, SD cards, PCIe cards, or rail kit

Description

The Cisco UCS C220 M4 SFF server:

Does not include power supply, CPU, memory, hard disk drives (HDDs), solid-state drives

(SSDs), SD cards, rail kit, or plug-in PCIe cards.

NOTE: Use the steps on the following pages to configure the server with the components that you want to include.

10 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 2 SELECT CPU(s)

The standard CPU features are:

Intel Xeon E5-2600 v3 series processor family CPUs

Intel C610 series chipset

Cache size of up to 45 MB

Select CPUs

The available CPUs are listed in

Table 3

.

Table 3 Available Intel CPUs: E5-2600 v3 Series Processor Family CPUs

Product ID (PID)

Intel

Number

Clock

Freq

(GHz)

Power

(W)

Cache

Size

(MB)

Cores QPI

UCS-CPU-E52699D

UCS-CPU-E52698D

UCS-CPU-E52697D

UCS-CPU-E52695D

UCS-CPU-E52690D

UCS-CPU-E52683D

UCS-CPU-E52680D

UCS-CPU-E52670D

UCS-CPU-E52667D

UCS-CPU-E52660D

UCS-CPU-E52650D

UCS-CPU-E52650LD

UCS-CPU-E52643D

UCS-CPU-E52640D

UCS-CPU-E52637D

UCS-CPU-E52630D

UCS-CPU-E52630LD

UCS-CPU-E52623D

UCS-CPU-E52620D

UCS-CPU-E52609D

2

E5-2699 v3

E5-2698 v3

E5-2697 v3

E5-2695 v3

E5-2690 v3

E5-2683 v3

E5-2680 v3

E5-2670 v3

E5-2667 v3

E5-2660 v3

E5-2650 v3

E5-2650L v3

E5-2643 v3

E5-2640 v3

E5-2637 v3

E5-2630 v3

E5-2630L v3

E5-2623 v3

E5-2620 v3

E5-2609 v3

2.30

2.30

2.60

2.30

2.60

2.00

2.50

2.30

3.20

2.60

2.30

1.80

3.40

2.60

3.50

2.40

1.80

3.00

2.40

1.90

145

135

145

120

135

120

120

120

135

105

105

65

135

90

135

85

55

105

85

85

45

40

35

35

30

35

30

30

20

25

25

30

20

20

15

20

20

10

15

15

18

16

14

14

12

14

12

12

8

10

10

12

6

8

4

8

8

4

6

6

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

9.6 GT/s

8.0 GT/s

9.6 GT/s

8.0 GT/s

8.0 GT/s

8.0 GT/s

8.0 GT/s

6.4 GT/s

Notes . . .

1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.

2. The E5-2609 v3 CPU does not support Intel Hyper-Threading or Intel Turbo Boost technologies.

Highest

DDR4 DIMM

Clock

Support

(MHz) 1

2133

2133

2133

2133

2133

2133

2133

2133

2133

2133

2133

1866

2133

1866

2133

1866

1866

1866

1866

1600

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

11

CONFIGURING the SERVER

Approved Configurations

(1) 1-CPU configurations:

Select any one CPU listed in

(2) 2-CPU Configurations:

Table 3 on page 11

.

Select two identical CPUs from any one of the rows of

Table 3 on page 11

.

Caveats

You can select either one processor or two identical processors.

For optimal performance, select DIMMs with the highest clock speed for a given processor

(see

Table 3 on page 11

). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result.

12 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 3 SELECT MEMORY

Figure 4

The standard memory features are:

DIMMs

— Clock speed: 2133 MHz

— Ranks per DIMM: 1, 2, or 4

— Operational voltage: 1.2 V

— Registered ECC DDR4 DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)

Memory is organized with four memory channels per CPU, with up to three DIMMs per channel, as shown in

Figure 4

.

C220 M4 SFF Memory Organization

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

13

CONFIGURING the SERVER

Select DIMMs and Memory Mirroring

Select the memory configuration and whether or not you want the memory mirroring option.

The available memory DIMMs and mirroring option are listed in

Table 4

.

NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored

DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data.

Table 4 Available DDR4 DIMMs

Product ID (PID) PID Description

DIMM Options

UCS-ML-1X324RU-A 32GB DDR4-2133-MHz LRDIMM/PC3-17000/quad rank/x4

UCS-MR-1X162RU-A 16GB DDR4-2133-MHz RDIMM/PC3-17000/dual rank/x4

UCS-MR-1X081RU-A 8GB DDR4-2133-MHz RDIMM/PC3-17000/single rank/x4

Memory Mirroring Option

N01-MMIRROR Memory mirroring option

Approved Configurations

Voltage

1.2 V

1.2 V

1.2 V

Ranks

/DIMM

4

2

1

(1) 1-CPU configuration without memory mirroring:

Select from 1 to 12 DIMMs. Refer to

Memory Population Rules, page 53

, for more detailed information.

14 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

(2) 1-CPU configuration with memory mirroring:

Select 2, 4, 6, 8, or 12 identical DIMMs. The DIMMs will be placed by the factory as shown in the following table.

Total

Number of

DIMMs

2

4

6

1

8

12

CPU 1 DIMM Placement in Channels

(for identical dual-rank DIMMs for 3DPC or identical quad-rank DIMMs for 2DPC)

Blue Slots

(A1, B1)

(A1,B1); (C1,D1)

(A1,B1,C1)

(A1,B1); (C1,D1)

(A1,B1); (C1,D1)

Notes . . .

1. Not recommended (for performance reasons)

Black Slots

(A2,B2,C2)

(A2,B2); (C2,D2)

(A2,B2); (C2,D2)

White Slots

(A3,B3); (C3,D3)

Select the memory mirroring option (N01-MMIRROR) as shown in

(3) 2-CPU configuration without memory mirroring:

Table 4 on page 14

.

Select from 1 to 12 DIMMs per CPU. Refer to

Memory Population Rules, page 53

, for more detailed information.

(4) 2-CPU configuration with memory mirroring:

Select 2, 4, 6, 8, or 12 identical DIMMs per CPU. The DIMMs will be placed by the factory as shown in the following table.

Number of

DIMMs per CPU

6

2

4

8

1

12

CPU 1 DIMM Placement in Channels

(for identical dual-rank DIMMs for 3DPC or identical quad-rank DIMMs for 2DPC)

Blue Slots

(A1, B1)

Black Slots

White Slots

(A1,B1);

(C1,D1)

(A1,B1, C1); (A2, B2, C2)

(A1,B1);

(C1,D1)

(A1,B1);

(C1,D1)

(A2,B2);

(C2,D2)

(A2,B2);

(C2,D2)

(A3, B3)

(C3, D3)

Notes . . .

1. Not recommended (for performance reasons)

CPU 2 DIMM Placement in Channels

(for identical dual-rank DIMMs for 3DPC or identical quad-rank DIMMs for 2DPC)

Blue Slots

(E1, F1)

Black Slots

White Slots

(E1,F1);

(G1,H1)

(E1,F1, G1);

(E2, F2, G2)

(E1,F1);

(G1,H1)

(E1,F1);

(G1,H1)

(E2,F2);

(G2,H2)

(E2,F2);

(G2,H2)

(E3,F3);

(G3,H3)

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

15

CONFIGURING the SERVER

Select the memory mirroring option (N01-MMIRROR) as shown in

Table 4 on page 14

.

NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the server.

Caveats

System speed is dependent on how many DIMMs are populated per channel and the CPU

DIMM speed support. See

Table 5

for details.

Table 5 DIMM Memory Speeds with Different CPUs

1600-MHz Capable CPU 1866-MHz Capable CPU 2133-MHz Capable CPU

DIMM Speed DPC

2133 DIMM

1

LRDIMM

(QR)

1DPC 1600

2DPC 1600

3DPC 1600

RDIMM (DR,

SR)

1600

1600

1600

LRDIMM

(QR)

1866

1866

1600

RDIMM (DR,

SR)

1866

1866

1600

LRDIMM

(QR)

2133

2133

1866

RDIMM (DR, SR)

2133

2133

1866 (16 GB DIMMs)

1600 (8 GB DIMMs)

Notes . . .

1. 2133-MHz DIMMs are the only offered and supported DIMMs for the C220 M4 server

The C220 M4 server supports four different memory reliability, availability, and serviceability (RAS) modes:

— Independent Channel Mode

— Mirrored Channel Mode

— Lockstep Channel Mode

Below are the system level RAS Mode combination limitations:

— Mixing of Independent and Lockstep channel mode is not allowed per platform.

— Mixing of Non-Mirrored and Mirrored mode is not allowed per platform.

— Mixing of Lockstep and Mirrored mode is not allowed per platform.

Do not mix RDIMMs with LRDIMMs

Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel

Do not mix quad-rank DIMMs with single- or dual-rank DIMMs in the same channel

For best performance, observe the following:

— DIMMs with different timing parameters can be installed on different slots within the same channel, but only timings that support the slowest DIMM will be applied to all.

16 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

As a consequence, faster DIMMs will be operated at timings supported by the slowest

DIMM populated.

— When one DIMM is used, it must be populated in DIMM slot 1 (farthest away from the

CPU) of a given channel.

— When single, dual or quad rank DIMMs are populated for 2DPC or 3DPC, always populate the higher number rank DIMM first (starting from the farthest slot). For a

3DPC example, first populate with quad-rank DIMMs in the DIMM slot 1. Then dual-rank DIMMs in the DIMM 2 slot. Then single-rank DIMMs in the DIMM 3 slot.

DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically.

When using mirroring, DIMMs must be installed in identical pairs across paired DDR4 buses.

That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical. However, the DIMMs used in channels A and B can be different from those in channels C and D.

Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must be even for mirroring).

Non-ECC DIMMs are not supported.

Pairs of DIMMs (A1/B1, A2/B2, etc) MUST be the exact same (same PID, rev, DIMM loading order)

Cisco memory from previous generation servers (DDR3) is not compatible with this server

For more information regarding memory, see

CPUs and DIMMs, page 52

.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

17

CONFIGURING the SERVER

STEP 4 SELECT RAID CONFIGURATION

NOTE: If you do not select a Cisco 12G SAS Modular RAID controller or the embedded software RAID 5 key upgrade, you will have two SATA-only RAID controllers that support up to two sets of four SATA-only drives (RAID 0, 1).

The embedded RAID controller hub is split into two controllers, SATA and sSATA

(secondary SATA). These two controllers are seen as separate RAID controllers in the

Cisco IMC interface and are configurable separately. For more details, see

Embedded SATA RAID: Two SATA Controllers, page 59

.

NOTE: When creating each RAID volume, follow these guidelines:

Use the same capacity for each drive in each RAID volume

Use either all SAS drives or all SATA drives in each RAID volume

Use either all HDDs or all SSDs in each RAID volume

The embedded SATA only RAID controllers have two ports and each port can control 4 drives, for 8 drives total. However, each set of 4 SATA drives for a port must be in separate RAID volumes. You cannot mix drives across ports to create a

RAID volume. For more details, see

Embedded SATA RAID: Two SATA

Controllers, page 59

.

NOTE: The number of RAID groups (virtual drives) supported per controller is as follows:

Embedded RAID = 8

Cisco 12G SAS Modular RAID controller = 64

The RAID controller choices are:

(1) Embedded Software RAID 5 Key Upgrade (on motherboard)

NOTE: The RAID configuration options listed in

Table 7 on page 20

are not available if you choose the embedded software RAID 5 key upgrade (in this case, you must configure RAID yourself using separate software).

(2) Cisco 12G SAS Modular RAID Controller

The C220 M4 server has a dedicated RAID controller slot on the motherboard that accommodates the Cisco 12G SAS Modular RAID controller for internal HDDs/SSDs. Cisco can provide factory-configured RAID setting options depending on the RAID controller chosen and the number of HDDs/SSDs ordered. Factory-configured RAID level options are listed with each RAID card description.

18 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Select RAID Options

Select one of the following:

Embedded software RAID 5 key upgrade option for internal drives (see

Table 6

), or

Cisco 12G SAS modular RAID controller for internal drives plus optional flash-backed write cache (FBWC) (see

Table 7 on page 20

), or

Dual controllers:

— One Cisco 12G SAS modular RAID controller for internal drives plus optional flash-backed write cache (FBWC), and

— One Cisco 9300-8E 12G SAS controller for external drives

(see

Table 7 on page 20

).

NOTE: The Cisco 12G SAS modular RAID controller can be ordered with or without an optional FBWC.

The FBWC option backs up the RAID controller write cache.

The

FBWC is available in 1 GB, 2 GB, or 4 GB sizes. See

Table 7 on page 20

for details.

NOTE: For all valid combinations of embedded RAID and internal/external RAID

controller combinations, see

RAID Details, page 57

.

Table 6

shows the product ID for the C220 M4 server entry-level RAID solution. This RAID option is accomplished with embedded software that supports a limited number of drives, operating systems, and virtualized environments. For a more comprehensive enterprise RAID solution, choose the Cisco 12G SAS

modular RAID controller listed in

Table 7 on page 20

.

Table 6 Entry Level RAID Solution

Product ID (PID) PID Description

Embedded Software RAID 5 Key Upgrade

UCSC-SWRAID5 Embedded Software RAID 5 key upgrade, consisting of a storage controller unit

(SCU) module that plugs into a 2-pin header on the motherboard, supporting

up to eight internal SATA only drives. See

Embedded SATA RAID: Two SATA

Controllers, page 59

. This module upgrades the embedded software RAID

controller options to add RAID 5. This option supports RAID 0, 1, 5, 10 and operates at 6 Gbps. Operating systems supported are Windows and Linux only

(no VMware support).

NOTE: VMware ESX/ESXi or any other virtualized environments are not supported for use with the embedded MegaRAID controller. Hypervisors such as Hyper-V, Xen, or

KVM are also not supported for use with the embedded MegaRAID controller

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

19

CONFIGURING the SERVER

Table 7 RAID Controller Options

Product ID (PID) PID Description

RAID Controller for Internal Drives

Note that if the following Cisco 12G SAS modular RAID controller is selected, it is factory-installed in a dedicated internal Cisco Modular RAID controller PCIe slot.

UCSC-MRAID12G Cisco 12G SAS Modular Raid Controller

Supports up to 8 internal SAS drives.

Supports JBOD, RAID 0, 1, 10

Flash-Backed Write Cache (FBWC) Upgrade Options for Cisco 12G SAS Modular RAID controller

UCSC-MRAID12G-1GB

UCSC-MRAID12G-2GB

1 GB FBWC, which includes a 1 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 5, 6, 10, 50, and 60.

2 GB FBWC, which includes a 2 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 5, 6, 10, 50, and 60.

UCSC-MRAID12G-4GB 4 GB FBWC, which includes a 4 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 5, 6, 10, 50, and 60.

SAS HBA for External JBOD Attach

Note that the Cisco 12G SAS 9300-8e, if selected, is installed by default in slot 1. Two SFF8644 mini-SAS x4 connectors on this card are accessible at the rear of the chassis.

UCSC-SAS9300-8E Cisco 12G SAS 9300-8e SAS HBA for external JBOD attach

Supports external JBOD using X4 and X8 wide SAS ports.

NOTE: For Cisco 12G SAS 9300-8e HBA external drive enclosure support, see the enclosure section of the compatibility list at the following link:

http://tinyurl.com/pp83xyk

Customers should contact their storage vendor for technical support related to external JBOD enclosures.

SuperCap Option

UCSC-MRAID-SC= Spare SuperCap for Cisco 12G SAS Modular RAID, including all cables. This is a spare SuperCap. It is the exact same SuperCap that ships with the FBWC options listed earlier in this table and can be used as a replacement or upgrade part.

20 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Table 7 RAID Controller Options (continued)

Product ID (PID) PID Description

RAID Configuration Options (not available for embedded RAID 5 key upgrade)

R2XX-SRAID0 Enable Single Disk Raid 0 Setting

R2XX-RAID0

R2XX-RAID1

R2XX-RAID5

R2XX-RAID6

R2XX-RAID10

Factory preconfigured RAID striping option

Enable RAID 0 Setting. Requires a minimum of one hard drive.

Factory preconfigured RAID mirroring option

Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity.

Factory preconfigured RAID option

Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity.

Factory preconfigured RAID option

Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity.

Factory preconfigured RAID option

Enable RAID 10 Setting. Requires a even number of drives (minimum of four drives) of the same size, speed, capacity.

NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown in

Table 7

.

Approved Configurations

The C220 M4 SFF server has an 8-drive backplane.

The embedded software RAID 5 upgrade key option supports up to eight internal SATA only drives.

The Cisco 12G SAS Modular RAID controller supports up to eight internal drives.

The Cisco 12G SAS 9300-8e PCIe external drive controller supports up to 8 external SAS+SATA ports

NOTE: If you do not select a Cisco 12G SAS Modular RAID controller, or the embedded software RAID 5 key upgrade option, you will have an embedded

SATA-only RAID controller that supports up to eight SATA-only drives (RAID 0, 1).

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

21

CONFIGURING the SERVER

See

Table 8

for a summary of the supported RAID configuration options.

Table 8 Supported RAID Configurations

Server # CPUs Embedded RAID

Cisco 12G SAS

Modular RAID

Controller 1

External PCIe

Controller 2

# Drives

Supported

C220 M4 SFF

8 HDD

C220 M4 SFF

8 HDD

C220 M4 SFF

8 HDD

C220 M4 SFF

8 HDD

C220 M4 SFF

8 HDD

C220 M4 SFF

8 HDD

C220 M4 SFF

8 HDD

C220 M4 SFF

8 HDD

1

1

1

1

2

2

2

2

Enabled

Not allowed

Not allowed

Not allowed

Enabled

Not allowed

Not allowed

Not allowed

Not allowed

Installed on Motherboard

Card absent

Installed

Installed on Motherboard

Card absent

Not allowed

Card absent

Installed slot 1 on Motherboard Installed slot 1

Not allowed

Installed on Motherboard

Not allowed

Card absent

Installed any slot

Installed any slot

8 internal SATA only

8 internal

0 internal

1024 external

8 internal

1024 external

8 internal SATA only

8 internal

0 internal

1024 external

8 internal

1024 external

Notes . . .

1. If you want to boot from a device other than the Cisco 12G SAS Modular RAID controller, you can leave the card installed. Just disable the OPROM for its slot, and the system will boot even with the card installed.

2. External PCIe drive controller card is the Cisco 12G SAS 9300-8e and can be installed simultaneously with the

Cisco 12G SAS Modular RAID controller.

Caveats

A maximum of one Cisco 12G SAS 9300-8e can be installed, and it can be installed only in slot 1. Note that a Storage Accelerator also can only be installed in slot 1. Therefore, the system can support either one storage accelerator card or one Cisco 12G SAS 9300-8e, but not both at the same time.

For the Cisco 12G SAS Modular RAID controller, you can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is preconfigured at the factory. The RAID level you choose must be an available RAID choice for the controller selected. RAID levels 50 and

60 are supported, although they are not available as configuration options.

A system supports up to eight SATA-only drives if no embedded software RAID 5 key upgrade controller or Cisco 12G SAS Modular RAID controller is chosen.

NOTE: For more important information regarding RAID support, see

RAID Details, page 57

and

RAID Option ROM (OPROM) Settings, page 58

.

22 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES

(SSDs)

The standard disk drive features are:

2.5-inch small form factor

Hot-pluggable

Drives come mounted in sleds

Select Drives

The available drives are listed in

Table 9

.

Table 9 Available Hot-Pluggable Sled-Mounted HDDs and SSDs

Product ID (PID) PID Description

HDDs (15K RPM)

UCS-HD600G15KS2-E 600 GB 6 Gbps SAS 15K RPM SFF HDD

UCS-HD450G15KS2-E 450 GB 6 Gbps SAS 15K RPM SFF HDD

UCS-HDD300GI2F105 300 GB 6 Gbps SAS 15K RPM SFF HDD

HDDs (10K RPM)

UCS-HD12T10KS2-E

A03-D300GA2

HDDs (7.2K RPM)

1.2 TB 6 Gbps SAS 10K RPM SFF HDD

UCS-HDD900GI2F106 900 GB 6 Gbps SAS 10K RPM SFF HDD

A03-D600GA2 600 GB 6 Gbps SAS 10K RPM SFF HDD

300 GB 6 Gbps SAS 10K RPM SFF HDD

UCS-HD1T7KS2-E

A03-D1TBSATA

1 TB 6 Gbps SAS 7.2K RPM SFF HDD

1 TB 6 Gbps SATA 7.2K RPM SFF HDD

Drive

Type

Capacity

SAS

SAS

SAS

600 GB

450 GB

300 GB

SAS

SAS

SAS

SAS

1.2 TB

900 GB

600 GB

300 GB

SAS 1 TB

SATA 1 TB

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

23

CONFIGURING the SERVER

Table 9 Available Hot-Pluggable Sled-Mounted HDDs and SSDs (continued)

Product ID (PID) PID Description

Drive

Type

Capacity

Enterprise Performance SSDs (high endurance, supports up to 10 FDWP (full drive writes per day)) 1

UCS-SD16T12S2-EP 1.6 TB Enterprise Performance 12 Gbps SAS eMLC SSD (Toshiba) SAS

UCS-SD800G0KS2-EP 800 GB Enterprise Performance 6 Gbps SAS eMLC SSD (Samsung) SAS

UCS-SD400G12S2-EP 400 GB Enterprise Performance 12 Gbps SAS eMLC SSD (Toshiba) SAS

1.6 TB

800 GB

400 GB

UCS-SD400G0KS2-EP 400 GB Enterprise Performance 6 Gbps SAS eMLC SSD (Samsung) SAS

UCS-SD200G0KS2-EP 200 GB Enterprise Performance 6 Gbps SAS eMLC SSD (Samsung) SAS

400 GB

200 GB

Enterprise Value SSDs (endurance of up to 1 FDWP (full drive write per day)) 2

UCS-SD960G0KS2-EV 960 GB 2.5 inch Enterprise Value 6 Gbps SAS SSD

UCS-SD480G0KS2-EV 480 GB 2.5 inch Enterprise Value 6 Gbps SAS SSD

UCS-SD240G0KS2-EV 240 GB 2.5 inch Enterprise Value 6 Gbps SAS SSD

UCS-SD120G0KS2-EV 120 GB 2.5 inch Enterprise Value 6 Gbps SAS SSD

SATA 960 GB

SATA 480 GB

SATA 240 GB

SATA 120 GB

Notes . . .

1. Targeted for IO write centric applications. Supports endurance of 10 FDWP (full drive writes per day). Target applications are caching, online transaction processing (OLTP), data warehousing, and virtual desktop infrastructure (VDI).

2. Targeted for IO read centric applications. Supports endurance of 1 FDWP (full drive writes per day). Target applications are boot, streaming media, and collaboration.

NOTE: When creating each RAID volume, follow these guidelines:

Use the same capacity for each drive in each RAID volume

Use either all SAS drives or all SATA drives in each RAID volume

Use either all HDDs or all SSDs in each RAID volume

The embedded SATA only RAID controllers have two ports and each port can control 4 drives, for 8 drives total. However, each set of 4 SATA drives for a port must be in separate RAID volumes. You cannot mix drives across ports to create a

RAID volume. For more details, see

Embedded SATA RAID: Two SATA

Controllers, page 59

.

24 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Approved Configurations

(1) Embedded RAID or Cisco 12G SAS Modular RAID Controller

If you have not selected an embedded software RAID 5 key upgrade option (UCSC-SWRAID5) or a Cisco 12G SAS Modular RAID controller for internal drives, you will have an SATA-only

RAID controller that supports up to eight SATA-only drives (RAID 0, 1). Select up to eight

SATA-only drives from

Table 9 on page 23

.

If you selected an embedded RAID 5 key upgrade option (supports RAID 0, 1, 5, and 10),

select up to eight SATA drives listed in

Table 9

.

If you selected a Cisco 12G SAS Modular RAID controller for internal HDDs/SSDs, you have the following options:

— Cisco 12G SAS Modular RAID controller with no FBWC option (supports JBOD, RAID 0,

1, 10)

— Cisco 12G SAS Modular RAID controller with FBWC option (supports JBOD, RAID 0, 1,

5, 10, 50, and 60)

— For either option, select up to eight SAS drives listed in

Table 9

.\

— See

SELECT RAID CONFIGURATION, page 18

for more details.

Caveats

You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all

SSDs in their own RAID volume

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

25

CONFIGURING the SERVER

STEP 6 SELECT PCIe OPTION CARD(s)

The standard PCie card offerings are:

Modular LAN on Motherboard (mLOM)

Virtual Interface Cards (VICs)

Network Interface Cards (NICs)

Converged Network Adapters (CNAs)

Host Bus Adapters (HBAs)

UCS Storage Accelerators

Select PCIe Option Cards

The available PCIe option cards are listed in

Table 10

.

Table 10 Available PCIe Option Cards

Product ID (PID) PID Description

Modular LAN on Motherboard (mLOM) 1

UCSC-MLOM-CSC-02 Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+

Virtual Interface Cards (VICs)

UCSC-PCIE-CSC-02 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA

UCSC-PCIE-C10T-02 Cisco VIC 1225T Dual Port 10GBaseT CNA

Network Interface Cards (NICs)

1 Gb NICs

UCSC-PCIE-IRJ45 Intel i350 Quad Port 1Gb Adapter

10 Gb NICs

N2XX-AIPCI01

UCSC-PCIE-ITG

Intel X520 Dual Port 10Gb SFP+ Adapter

Intel X540 Dual Port 10GBase-T Adapter

Card

Height

N/A

Half

Half

Half

Half

Half

26 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Table 10 Available PCIe Option Cards (continued)

Product ID (PID) PID Description

Card

Height

10 Gb Converged Network Adapters (CNAs)

UCSC-PCIE-E14102 Emulex OCe14102-UX dual-port 10 GbE FCoE CNA

Host Bus Adapters (HBAs)

N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA

UCSC-PCIE-Q2672

N2XX-AEPCI05

UCSC-PCIE-E16002

Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics

Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA

Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics

UCS Storage Accelerators

2

UCSC-F-FIO-1000PS

UCSC-F-FIO-1300PS

UCSC-F-FIO-2600PS

UCSC-F-FIO-5200PS

UCSC-F-FIO-3200SS

UCSC-F-FIO-6400SS

UCS 1000GB Fusion ioMemory3 PX Performance line for C-Series

UCS 1300GB Fusion ioMemory3 PX Performance line for C-Series

UCS 2600GB Fusion ioMemory3 PX Performance line for C-Series

UCS 5200GB Fusion ioMemory3 PX Performance line for C-Series

UCS 3200GB Fusion ioMemory3 SX Scale line for C-Series

UCS 6200GB Fusion ioMemory3 SX Scale line for C-Series

Half

Half

Half

Half

Half

Half

Half

Half

Full

Half

Full

Notes . . .

1. The mLOM cards do not plug into any of the riser 1 or riser 2 card slots; instead, they plug into a connector inside the server chassis.

2. A maximum of one storage accelerator card is supported and it must be installed in slot 1 only. Note that the

Cisco 12G SAS 9300-8e also can only be installed in slot 1.

Approved Configurations

(1) 1-CPU Systems

You can select up to one PCie option card (slot 1 for 1-CPU systems) listed in

Table 10 on page 26

.

(2) 2-CPU Systems

You can select up to two PCie option cards (slots 1 and 2 for 2-CPU systems) listed in

Table 10 on page 26

.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

27

CONFIGURING the SERVER

Caveats

A maximum of one storage accelerator card is supported and it must be installed in slot 1 only. Note that the Cisco 12G SAS 9300-8e also can only be installed in slot 1. Therefore, the system can support either one storage accelerator card or one Cisco 12G SAS 9300-8e, but not both at the same time.

For 1-CPU systems:

— Only the full-height PCIe slot on riser 1 (slot 1) is supported

— Only a single plug-in PCIe VIC card is supported and must be installed in slot 1 (the full-height slot). However, in addition to the one PCIe VIC card, you can also choose to install an mLOM VIC card.

— If any of the Storage Accelerator cards are installed, they can be installed only in slot 1.

For 2-CPU systems:

— Both PCIe slots (slots 1 and 2) are supported

— Only a single plug-in PCIe VIC card is supported and it must be installed in slot 1 (the full height slot). However, in addition to the one PCIe VIC card, you can also choose an mLOM VIC card.

— If any of the Storage Accelerator cards are installed, they can be installed only in slot 1.

Other considerations for the Cisco VIC 1225/1227/1225T cards:

— VIC 1225 and VIC 1227 Supports 10G SFP+ optical and copper twinax connections

— VIC 1225T Supports RJ45 Category 6 or better twisted pair cable connections

— The server supports installation of one PCIe Cisco VIC 1225/1225Tcard and it is supported only in PCIe slot 1.

— For the Cisco UCS VIC1225, requires that the server has CIMC firmware version 1.4(6) or later installed and VIC firmware of 2.1(0) or later. For the Cisco UCS VIC1225T, requires that the server has CIMC firmware version 1.5(1) or later installed and VIC firmware of 2.1(1) or later.

To help ensure that your operating system is compatible with the card you have selected, or to see additional cards that have been qualified to work with the UCS C220 M4 server, but are not sold on the Cisco pricelist, check the Hardware Compatibility List at this URL:

http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html

28 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES

Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server.

Choose Optional Twinax Cables

Table 11

lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality.

Table 11 Available Twinax Cables

Product ID (PID)

SFP-H10GB-CU1M

SFP-H10GB-CU3M

SFP-H10GB-CU5M

SFP-H10GB-ACU7M

SFP-H10GB-ACU10M

PID Description

10GBASE-CU SFP+ Cable (1 M)

10GBASE-CU SFP+ Cable (3 M)

10GBASE-CU SFP+ Cable (5 M)

10GBASE-CU SFP+ Cable (7 M)

10GBASE-CU SFP+ Cable (10 M)

Approved Configurations

(1) Choose Up to Two Twinax Cables for Each Network Card Ordered

You may choose one or two twinax cables for each compatible PCIe network card ordered.

The cables can be different lengths; however, you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment.

Choose Optional SFP Modules

Optical Cisco SFP+ modules are listed in

Table 12

.

Table 12 Available SFP Modules

Product ID (PID)

SFP-10G-SR

DS-SFP-FC8G-SW

PID Description

10GBASE-SR SFP+ Module

850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring

8 Gbit SFP+ Module

850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

29

CONFIGURING the SERVER

Approved Configurations

(1) Choose Up to Two SFP+ Modules for Each Network Card Ordered

You may choose one or two SFP+ optical modules cables for each compatible PCIe network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available.

See the

Figure 5 on page 32

for typical SFP+ and twinax connections to the network cards.

Caveats

Check the table on the following page for compatibility between the PCIe network cards and

SFPs or twinax cables.

NOTE: The table shows all PCIe network cards for all C-series servers. Not all of the cards shown in the table are supported in this server. The intent of the table is to show compatibility between cards and twinax cables or SFPs.

30 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Table 13 PCIe Card Compatibility

PCIe Cards

Converged Network Adapters (CNAs)

UCSC-PCIE-BSFP

(Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI)

UCSC-PCIE-CSC-02

(Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)

UCSC-PCIE-C10T-02

(Cisco VIC 1225T Dual Port 10GBaseT CNA)

UCSC-PCIE-C40Q-02

(Cisco VIC 1285 Dual Port 40Gb QSFP CNA)

UCSC-PCIE-C40Q-03

(Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA)

UCSC-PCIE-ESFP

(Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA))

UCSC-PCIE-QSFP

(QLogic QLE8242-CU dual-port 10 GbE FCoE CNA)

UCSC-PCIE-B3SFP

(Broadcom 57810 10Gb A-FEX SFP+

UCSC-PCIE-Q8362

(Qlogic QLE8362 dual-port 10 GbE FCoE CNA)

UCSC-PCIE-E14102

(Emulex OCe14102-UX dual-port 10 GbE FCoE CNA)

Network Interface Cards (NICs)

N2XX-ABPCI01-M3

(Broadcom 5709 Dual-Port Ethernet PCIe Adapter for M3

Servers)

N2XX-ABPCI03-M3

(Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3

Servers

N2XX-AIPCI01

(Intel X520 Dual Port 10Gb SFP+ Adapter)

UCSC-PCIE-ITG

(Intel X540 Dual Port 10GBase-T Adapter)

UCSC-PCIE-IRJ45

(Intel i350 Quad Port 1Gb Adapter

UCSC-PCIE-BTG

(Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI)

Host Bus Adapters (HBAs)

N2XX-AEPCI03

(Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA

N2XX-AEPCI05

(Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA)

N2XX-AQPCI03

(QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA)

Twinax

Cables

Cisco SFP Modules

SFP-10G-SR DS-SFP-FC8G-SW

Yes

Yes

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

Yes

Yes

No

No

No

Yes

Yes

Yes

No

Use RJ45 Ethernet cable

No

Use RJ45 Ethernet cable

No

1

1

Use Qlogic SFP

Use Qlogic SFP

Use Intel SFP

No

No

No

No

No

No

No

No

No

No

No

Preinstalled - do not change SFP

Preinstalled - do not change SFP

Preinstalled - do not change SFP

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

31

CONFIGURING the SERVER

Table 13 PCIe Card Compatibility (continued)

PCIe Cards

N2XX-AQPCI05

(QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA)

UCSC-PCIE-Q2672

(Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics)

UCSC-PCIE-E16002

(Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics)

Notes . . .

1. This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable.

Twinax

Cables

Cisco SFP Modules

SFP-10G-SR DS-SFP-FC8G-SW

No Preinstalled - do not change SFP

No

No

Preinstalled - do not change SFP

Preinstalled - do not change SFP

Figure 5 Network Card Connections

32 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 8 ORDER POWER SUPPLY

The C220 M4 SFF server accommodates two power supplies. A lightly loaded server can operate from one 770 W power supply. A fully loaded server might need to be powered with two 770 W power supplies (see

Table 14

).

Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on):

https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx

Table 14 Power Supply PIDs

Product ID (PID)

UCSC-PSU1-770W

PID Description

770 W power supply

NOTE: In a two power supply server, both power supplies must be identical.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

33

CONFIGURING the SERVER

STEP 9 SELECT AC POWER CORD(s)

Using

Table 15

, select the appropriate AC power cords. You can select a minimum of no power

cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.

Table 15 Available Power Cords

Product ID (PID) PID Description

R2XX-DMYMPWRCORD No power cord (dummy PID to allow for a no power cord option)

CAB-N5K6A-NA Power Cord, 200/240V 6A, North

America

Images

Not applicable

Plug: NEMA 6-15P

Cordset rating: 10 A, 250 V

Length: 8.2 ft

Connector:

IEC60320/C13

CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,

2M/6.5ft

CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L,

C13/C14, 10A/250V

CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR,

2 Meter, C13/C14,10A/250V

CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6

0320/C13, 3.0M

34 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Table 15 Available Power Cords

Product ID (PID)

SFS-250V-10A-AR

CAB-9K10A-AU

PID Description

Power Cord, SFS, 250V, 10A,

Argentina

Power Cord, 250VAC 10A 3112 Plug,

Australia

Images

Plug:

EL 219

(IRAM 2073)

2500 mm

Cordset rating: 10 A, 250/500 V MAX

Length: 8.2 ft

Connector:

EL 701

(IEC60320/C13)

Plug:

EL 210

Cordset rating: 10 A, 250 V/500 V MAX

Length: 2500mm

Connector:

EL 701C

(EN 60320/C15)

(BS 1363A) 13 AMP fuse

SFS-250V-10A-CN Power Cord, SFS, 250V, 10A, China

Plug:

EL 218

(CCEE GB2009)

Cordset rating 10A, 250V

(2500 mm)

Connector:

EL 701

(IEC60320/C13)

CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC

CAB-9K10A-EU

SFS-250V-10A-ID

SFS-250V-10A-IS

Power Cord, 250VAC 10A CEE 7/7

Plug, EU

Power Cord, SFS, 250V, 10A, India

Plug:

EL 208

Power Cord, SFS, 250V, 10A, Israel

EL-212

16A

250V

Plug:

EL 212

(SI-32)

Plug:

M2511

Cordset rating: 10A/16 A, 250 V

Length: 8 ft 2 in. (2.5 m)

Connector:

VSCC15

Cordset rating 16A, 250V

(2500mm)

Connector:

EL 701

Cordset rating 10A, 250V/500V MAX

(2500 mm)

Connector:

EL 701B

(IEC60320/C13)

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

35

CONFIGURING the SERVER

Table 15 Available Power Cords

Product ID (PID)

CAB-9K10A-IT

PID Description

Power Cord, 250VAC 10A CEI

23-16/VII Plug, Italy

Images

Plug:

I/3G

(CEI 23-16)

Cordset rating: 10 A, 250 V

Length: 8 ft 2 in. (2.5 m)

Connector

C15M

(EN60320/C15 )

CAB-9K10A-SW Power Cord, 250VAC 10A MP232

Plug, Switzerland

Plug:

MP232-R

Cordset rating: 10 A, 250 V

Length: 8 ft. 2 in (2.5 m)

Connector:

IEC 60320 C15

CAB-9K10A-UK Power Cord, 250VAC 10A BS1363

Plug (13 A fuse), UK

Plug:

EL 210

Cordset rating: 10 A, 250 V/500 V MAX

Length: 2500mm

Connector:

EL 701C

(EN 60320/C15)

(BS 1363A) 13 AMP fuse

CAB-9K12A-NA Power Cord, 125VAC 13A NEMA

5-15 Plug, North America

CAB-250V-10A-BR Power Cord - 250V, 10A - Brazil

CAB-JPN-3PIN Power Cord 3PIN, Japan

1

76.2 From Plug End

2,133.6 ± 25

Image not available

36 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 10 ORDER RAIL KIT AND OPTIONAL REVERSIBLE CABLE

MANAGEMENT ARM

Select a Rail Kit

Select a rail kit from

Table 17

.

Table 16 Rail Kit Options

Product ID (PID)

UCSC-RAILF-M4

UCSC-RAILB-M4

PID Description

Friction Rail Kit for C220 M4 Servers

Ball Bearing Rail Kit for C220 M4 and C240 M4 Servers

Select an Optional Reversible Cable Management Arm

The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use

Table 17

to order a cable management arm.

Table 17 Cable Management Arm

Product ID (PID)

UCSC-CMA1

PID Description

Cable Management Arm for C220 rack servers

For more information about the rail kit and cable management arm, see the Cisco UCS C220 M4

Installation and Service Guide at this URL:

http://www.cisco.com/c/en/US/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html

NOTE: If you plan to rackmount your UCS C220 M4 server, you must order a tool-less rail kit.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

37

CONFIGURING the SERVER

STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL)

Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.

The TPM ordering information is listed in

Table 18

.

Table 18 Trusted Platform Module

Product ID (PID)

UCSX-TPM2-001

PID Description

Trusted Platform Module 1.2 SPI-based for UCS Servers

NOTE: The module used in this server conforms to TPM v1.2/1.3, as defined by the

Trusted Computing Group (TCG). It is also SPI-based.

38 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL)

You can order 64 GB SD cards or 32 GB SD cards. See

Figure 6 on page 51

for the location of the

SD cards. There are two locations, SD1 and SD2.

Table 19 64 GB Secure Digital (SD) Card (blank)

Product ID (PID)

UCS-SD-64G-S

PID Description

64 GB SD Card for UCS Servers

Table 20 32 GB Secure Digital (SD) Card (blank)

Product ID (PID)

UCS-SD-32G-S

PID Description

32 GB SD Card for UCS Servers

Caveats

Install either one or two 64 GB SD cards or one or two 32 GB SD cards

Do not mix SD card sizes

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

39

CONFIGURING the SERVER

STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE

Several operating systems and value-added software programs are available. Select as desired

from

Table 21

.

Table 21 OSs and Value-Added Software (for 2-CPU servers)

PID Description Product ID (PID)

Microsoft Windows Server

MSWS-08R2-STHV Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL)

MSWS-08R2-ENHV

MSWS-08R2-DCHV2S

Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL)

Windows Svr 2008 R2-2 CPU-Data Center

MSWS-12-ST2S

MSWS-12-DC2S

MSWS-12-ST2S-NS

MSWS-12-DC2S-NS

Windows Server 2012 Standard (2 CPU/2 VMs)

Windows Server 2012 Datacenter (2 CPU/Unlimited VMs)

Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC

Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco SVC

MSWS-12R2-ST2S

MSWS-12R2-DC2S

MSWS-12R2-ST2S-NS

MSWS-12R2-DC2S-NS

SUSE

SLES-SVR-2S-1G-1A

Windows Server 2012 R2 Standard (2 CPU/2 VMs)

Windows Server 2012 R2 Datacenter (2 CPU/Unlimited VMs)

Windows Server 2012 R2 Standard (2 CPU/2 VMs) No Cisco SVC

Windows Server 2012 R2 Datacen (2 CPU/Unlim VM) No Cisco Svc

SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);1yr Support Reqd

SLES-SVR-2S-1G-3A

SLES-SVR-2S-1G-5A

SLES-SVR-2S-UG-1A

SLES-SVR-2S-UG-3A

SLES-SVR-2S-UG-5A

SLES-SHA-2S-1A

SLES-SHA-2S-3A

SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);3yr Support Reqd

SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);5yr Support Reqd

SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);1yr Support Reqd

SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);3yr Support Reqd

SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);5yr Support Reqd

SUSE Linux High Availability Ext (1-2 CPU); 1yr Support Reqd

SUSE Linux High Availability Ext (1-2 CPU); 3yr Support Reqd

SLES-SHA-2S-5A

SLES-HGC-2S-1A

SLES-HGC-2S-3A

SLES-HGC-2S-5A

SLES-SAP-2S-1G-1A

SLES-SAP-2S-1G-3A

SLES-SAP-2S-1G-5A

SLES-SAP-2S-UG-1A

SLES-SAP-2S-UG-3A

SLES-SAP-2S-UG-5A

SUSE Linux High Availability Ext (1-2 CPU); 5yr Support Reqd

SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Support Reqd

SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr Support Reqd

SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr Support Reqd

SLES for SAP Applications (1-2 CPU,1 Phys); 1yr Support Reqd

SLES for SAP Applications (1-2 CPU,1 Phys); 3yr Support Reqd

SLES for SAP Applications (1-2 CPU,1 Phys); 5yr Support Reqd

SLES for SAP Applications (1-2 CPU,Unl Vrt);1yr Support Reqd

SLES for SAP Applications (1-2 CPU,Unl Vrt);3yr Support Reqd

SLES for SAP Applications (1-2 CPU,Unl Vrt);5yr Support Reqd

40 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Table 21 OSs and Value-Added Software (for 2-CPU servers) (continued)

PID Description Product ID (PID)

Red Hat Enterprise Linux

RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required

RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required

RHEL-2S-4G-1A

RHEL-2S-4G-3A

RHEL/2 Socket/4 Guest/1Yr Svcs Required

RHEL/2 Socket/4 Guest/3Yr Svcs Required

RHEL-2S-UG-1A

RHEL-2S-UG-3A

RHEL-HA-2S-1A

RHEL-HA-2S-3A

RHEL-RS-2S-1A

RHEL/2 Socket/U Guest/1Yr Svcs Required

RHEL/2 Socket/U Guest/3Yr Svcs Required

RHEL Option/High-Availability/2 Socket/1Yr Svcs Required 

RHEL Option/High-Availability/2 Socket/3Yr Svcs Required 

RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required 

RHEL-RS-2S-3A

RHEL-SFS-2S-1A

RHEL-SFS-2S-3A

RHEL Option/Resilient Storage w/ HA /2 Socket/3 Yr Svcs Reqd 

RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required  

RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required

BMC

BMC-012

BMC-SE-4C

BMC-SE-6C

BMC-SE-8C

BMC-SE-10C

BMC-AE-4C

BMC BPPM Per Server 

BMC BladeLogic Standard Edition, 4 Cores, Support Required

BMC BladeLogic Standard Edition, 6 Cores, Support Required

BMC BladeLogic Standard Edition, 8 Cores, Support Required

BMC BladeLogic Standard Edition, 10 Cores, Support Required

BMC BladeLogic Advanced Edition, 4 Cores, Support Required

BMC-AE-6C

BMC-AE-8C

BMC BladeLogic Advanced Edition, 6 Cores, Support Required

BMC BladeLogic Advanced Edition, 8 Cores, Support Required

BMC-AE-10C BMC BladeLogic Standard Edition, 10 Cores, Support Required

Nexus 1000V for Hyper-V and vSphere

N1K-VSG-UCS-BUN Over half off N1K and VSG w/ purchase of UCS B/C Series

N1K-VLEM-UCS-1

VSG-VLEM-UCS-1

UCS Director

CUIC-PHY-SERV-BM-U

Nexus 1000V License Paper Delivery (1 CPU) for bundles

VSG License Paper Delivery (1 CPU) for bundles

CUIC-PHY-SERV-U

CUIC-TERM

Cisco Cloupia Resource Lic - One Phy Server node bare metal

Cisco Cloupia Resource Lic - One physical Server node

Acceptance of Cisco Cloupia License Terms

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

41

CONFIGURING the SERVER

Table 21 OSs and Value-Added Software (for 2-CPU servers) (continued)

PID Description

VMware 5

VMW-VS5-STD-1A

VMW-VS5-STD-2A

VMW-VS5-STD-3A

VMW-VS5-STD-4A

VMW-VS5-STD-5A

VMW-VS5-ENT-1A

VMW-VS5-ENT-2A

VMW-VS5-ENT-3A

VMW-VS5-ENT-4A

VMW-VS5-ENT-5A

VMW-VS5-ENTP-1A

VMW-VS5-ENTP-2A

VMW-VS5-ENTP-3A

VMW-VS5-ENTP-4A

VMW-VS5-ENTP-5A

VMW-VC5-STD-1A

VMW-VC5-STD-2A

VMW-VC5-STD-3A

VMW-VC5-STD-4A

VMW-VC5-STD-5A

UCS-VMW-TERMS

Product ID (PID)

VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd

VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd

VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd

VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd

VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Rqd

VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Rqd

VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Rqd

VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Rqd

VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Rqd

VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Rqd

VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Rqd

VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Rqd

VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Rqd

VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Rqd

VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Rqd

VMware vCenter 5 Server Standard, 1 yr support required 

VMware vCenter 5 Server Standard, 2 yr support required 

VMware vCenter 5 Server Standard, 3 yr support required 

VMware vCenter 5 Server Standard, 4 yr support required 

VMware vCenter 5 Server Standard, 5 yr support required 

Acceptance of Terms, Standalone VMW License for UCS Servers 

42 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 14 SELECT OPERATING SYSTEM MEDIA KIT

Select the optional operating system media listed in

Table 22

.

Table 22 OS Media

Product ID (PID)

RHEL-6

SLES-11

MSWS-08R2-STHV-RM

MSWS-08R2-ENHV-RM

MSWS-08R2-DCHV-RM

MSWS-12-ST2S-RM

MSWS-12-DC2S-RM

MSWS-12R2-ST2S-RM

MSWS-12R2-DC2S-RM

PID Description

RHEL 6 Recovery Media Only (Multilingual)

SLES 11 media only (multilingual)

Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media

Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media

Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media

Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media

Windows Server 2012 Datacenter(2 CPU/Unlimited VM) Rec Media

Windows Server 2012 R2 Standard (2 CPU/2 VMs) Recovery Media

Windows Server 2012 R2 Datacen (2 CPU/Unlimited VM) Rec Media

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

43

CONFIGURING the SERVER

STEP 15 SELECT SERVICE and SUPPORT LEVEL

A variety of service options are available, as described in this section.

Unified Computing Warranty, No Contract

If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:

Three-year parts coverage.

Next business day (NBD) onsite parts replacement eight hours a day, five days a week.

90-day software warranty on media.

Ongoing downloads of BIOS, drivers, and firmware updates.

UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.

SMARTnet for UCS

For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS

Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco

Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.

For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours.

There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in

Table 23

.

Table 23 Cisco SMARTnet for UCS Service

Product ID (PID) On Site? Description

CON-PREM-C220M4SF Yes

CON-OSP-C220M4SF

CON-OSE-C220M4SF

Yes

Yes

CON-OS-C220M4SF Yes

CON-S2P-C220M4SF No

CON-SNTP-C220M4SF No

CON-SNTE-C220M4SF

CON-SNT-C220M4SF

No

No

ONSITE 24X7X2 UCS C220 M4 SFF

ONSITE 24X7X4 UCS C220 M4 SFF

ONSITE 8X5X4 UCS C220 M4 SFF

ONSITE 8X5XNBD UCS C220 M4 SFF

SMARTNET 24X7X2 UCS C220 M4 SFF

SMARTNET 24X7X4 UCS C220 M4 SFF

SMARTNET 8X5X4 UCS C220 M4 SFF

SMARTNET 8X5XNBD UCS C220 M4 SFF

44 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

SMARTnet for UCS Hardware Only Service

For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a service listed in

Table 24

.

Table 24 SMARTnet for UCS Hardware Only Service

Product ID (PID)

CON-UCW7-C220M4SF

CON-UCW5-C220M4SF

Service

Level GSP

UCW7

UCW5

On

Site?

Yes

Yes

Description

UCS HW 24X7X4OS UCS C220 M4 SFF

UC PLUS 8X5XNBDOS UCS C220 M4 SFF

Unified Computing Partner Support Service

Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:

Expand their service portfolios to support the most complex network environments

Lower delivery costs

Deliver services that increase customer loyalty

Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets.

This helps partners to realize higher margins and expand their practice.

PSS is available to all Cisco PSS partners, but requires additional specializations and requirements. For additional information, see the following URL:

www.cisco.com/go/partnerucssupport

The two Partner Unified Computing Support Options include:

Partner Support Service for UCS

Partner Support Service for UCS Hardware Only

Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

45

CONFIGURING the SERVER

See

Table 25

.

Table 25 Partner Support Service for UCS

Product ID (PID)

CON-PSJ1-C220M4SF

CON-PSJ2-C220M4SF

CON-PSJ3-C220M4SF

CON-PSJ4-C220M4SF

Service

Level

GSP

PSJ1

PSJ2

PSJ3

PSJ4

On

Site?

No

No

No

No

Description

UCS SUPP PSS 8X5XNBD UCS C220 M4 SFF

UCS SUPP PSS 8X5X4 UCS C220 M4 SFF

UCS SUPP PSS 24X7X4 UCS C220 M4 SFF

UCS SUPP PSS 24X7X2 UCS C220 M4 SFF

Partner Support Service for UCS Hardware Only provides customers with replacement parts in as

little as two hours. See

Table 26

.

Table 26 Partner Support Service for UCS (Hardware Only)

Product ID (PID)

CON-PSW2-C220M4SF

CON-PSW3-C220M4SF

CON-PSW4-C220M4SF

Service

Level GSP

PSW2

PSW3

PSW4

On

Site?

No

No

No

Description

UCS W PL PSS 8X5X4 UCS C220 M4 SFF

UCS W PL PSS 24X7X4 UCS C220 M4 SFF

UCS W PL PSS 24X7X2 UCS C220 M4 SFF

Unified Computing Combined Support Service

Combined Services makes it easier to purchase and manage required services under one contract. SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:

Optimize the uptime, performance, and efficiency of your UCS

Protect your vital business applications by rapidly identifying and addressing issues

Strengthen in-house expertise through knowledge transfer and mentoring

Improve operational efficiency by allowing UCS experts to augment your internal staff resources

Enhance business agility by diagnosing potential issues before they affect your operations

46 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

You can choose a service listed in

Table 27

.

Table 27 UCS Computing Combined Support Service

Product ID (PID)

Service

Level GSP

On

Site?

Description

CON-NCF2-

C220M4SF

CON-NCF2P-

C220M4SF

NCF2

NCF2P

CON-NCF4P-

C220M4SF

NCF4P

CON-NCF4S-

C220M4SF

NCF4S

CON-NCFCS-

C220M4SF

NCFCS

CON-NCFE-

C220M4SF

NCFE

CON-NCFP-

C220M4SF

NCFP

CON-NCFT-

C220M4SF

NCFT

Yes

No

No

No

No

Yes

Yes

Yes

CMB SPT SVC 24X7X2 UCS C220 M4 SFF

CMB SPT SVC 24X7X2OS

UCS C220 M4 SFF

CMB SPT SVC 24X7X4OS

UCS C220 M4 SFF

CMB SPT SVC 8X5X4OS

UCS C220 M4 SFF

CMB SPT SVC 8X5XNBDOS

UCS C220 M4 SFF

CMB SPT SVC 8X5X4

UCS C220 M4 SFF

CMB SPT SVC 24X7X4

UCS C220 M4 SFF

CMB SPT SVC 8X5XNBD

UCS C220 M4 SFF

Unified Computing Drive Retention Service

With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.

Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.

If your company has a need to control confidential, classified, sensitive, or proprietary data, you

might want to consider one of the Drive Retention Services listed in

Table 28

.

NOTE: Cisco does not offer a certified drive destruction service as part of this service.

Table 28 Drive Retention Service Options

Service Description

Service

Program Name

SMARTnet for UCS

Service with Drive

Retention

UCS DR

Service

Level GSP

UCSD7

UCSD5

Service Level

24x7x4 Onsite

8x5xNBD Onsite

Product ID (PID)

CON-UCSD7-C220M4SF

CON-UCSD5-C220M4SF

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

47

CONFIGURING the SERVER

Table 28 Drive Retention Service Options (continued)

Service Description

SMARTnet for UCS

HW ONLY+Drive

Retention

Service

Program Name

UCS HW+DR

Service

Level GSP

UCWD7

UCWD5

Service Level

24x7x4 Onsite

8x5xNBD Onsite

Product ID (PID)

CON-UCWD7-C220M4SF

CON-UCWD5-C220M4SF

For more service and support information, see the following URL:

http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf

For a complete listing of available services for Cisco Unified Computing System, see this URL:

http://www.cisco.com/en/US/products/ps10312/serv_group_home.html

48 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

OPTIONAL STEP - ORDER RACK(s)

OPTIONAL STEP - ORDER RACK(s)

The optional R42610 rack is available from Cisco for the C-Series servers, including the C220 M4

SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in

Table 29

. Racks are shipped separately from the C220 M4 SFF server.

Table 29 Racks and Rack Options

Product ID (PID)

RACK-UCS 1

PID Description

Cisco R42610 expansion rack, no side panels

RACK-UCS2

1

RACK-BLANK-001

Cisco R42610 standard rack, w/side panels

Filler panels (qty 12), 1U, plastic, toolless

RACK-CBLMGT-001

RACK-CBLMGT-011

RACK-FASTEN-001

RACK-FASTEN-002

RACK-JOIN-001

Cable mgt D rings (qty 10), metal

Cable mgt straps (qty 10), Velcro

Mounting screws (qty 100), M6

Cage nuts (qty 50), M6

Rack joining kit

Notes . . .

1. Use these same base PIDs to order spare racks (available only as next-day replacements).

For more information about the R42610 rack, see

RACKS, page 66

.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

49

OPTIONAL STEP - ORDER PDU

OPTIONAL STEP - ORDER PDU

An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC220 M4 server. This PDU is available in a zero rack unit (RU) style (see

Table 29

).

Table 30 PDU Options

Product ID (PID)

RP208-30-2P-U-2

PID Description

Zero RU PDU

For more information about the PDU, see

PDUs, page 68

.

50 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL

CHASSIS

Figure 6

An internal view of the C220 M4 chassis with the top cover removed is shown in

Figure 6

.

C220 M4 SFF With Top Cover Off

2 3

4 5

6 7 8

PSU 2

FAN 6

FAN 5

FAN 4

SD 1

CPU 2

SD 2

PSU 1

9

1

PCIe Riser 2

PCIe Riser 1

10

11

12

FAN 3

FAN 2

FAN 1

CPU 1

13

17 16 15 14

1

2

3

4

5

8

9

6

7

Drives (SAS/SATA drives are hot-swappable)

Cooling fan modules (six)

SuperCap backup unit mounting location

DIMM sockets on motherboard (24)

CPUs and heatsinks (up to two)

Embedded SATA RAID header for RAID 5 key

SD card bays on motherboard (two)

Internal USB 3.0 port on motherboard

Power supplies (up to two, hot-swappable when redundant as 1+1)

10

11

12

13

14

15

16

17

Trusted platform module (TPM) socket on motherboard (not visible in this view)

PCIe riser 2 (half-height PCIe slot 2)

PCIe riser 1 (full-height PCIe slot 1)

Modular LOM (mLOM) connector on chassis floor

Cisco modular RAID controller PCIe riser

(dedicated riser with horizontal socket)

Cisco modular RAID controller card

Embedded SATA RAID mini-SAS connectors on motherboard (not visible in this view)

RTC battery on motherboard

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

51

SUPPLEMENTAL MATERIAL

CPUs and DIMMs

Physical Layout

Each CPU has four DIMM channels:

CPU1 has channels A, B, C, and D

CPU2 has channels E, F, G, and H

Each DIMM channel has three slots: slot 1, slot 2, and slot 3. The blue-colored DIMM slots are for slot 1, the black-colored slots for slot 2, and the white slots for slot 3.

As an example, DIMM slots A1, B1, C1, and D1 belong to slot 1, while A2, B2, C2, and D2 belong to slot 2.

Figure 7

shows how slots and channels are physically laid out on the motherboard. The DIMM slots on the

right half of the motherboard (channels A, B, C, and D) are associated with CPU 1, while the DIMM slots on the left half of the motherboard (channels E, F, G, and H) are associated with CPU 2. The slot 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding slot 2 (black) and slot 3 (white) slots. Slot 1 slots (blue) are populated before slot 2 slots (black) and slot 3 (white) slots.

Figure 7 Physical Layout of CPU DIMM Channels and Slots

52 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

Memory Population Rules

When considering the memory configuration of your server, you should consider the following items:

Each channel has three DIMM slots (for example, channel A = slots A1, A2, and A3).

— A channel can operate with one, two, or three DIMMs installed.

— If a channel has only one DIMM, populate slot 1 first (the blue slot).

When both CPUs are installed, populate the DIMM slots of each CPU identically.

— Fill blue slots in the channels first: A1, E1, B1, F1, C1, G1, D1, H1

— Fill black slots in the channels second: A2, E2, B2, F2, C2, G2, D2, H2

— Fill white slots in the channels third: A3, E3, B3, F3, C3, G3, D3, H3

Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.

Observe the DIMM mixing rules shown in

Table 31

Table 31 DIMM Rules for C220 M4 Servers

DIMM Parameter DIMMs in the Same Channel

DIMM in the Same Slot 1

DIMM Capacity

RDIMM = 8 or 16 GB

LRDIMM = 32 GB

DIMM Speed

2133-MHz 2

DIMMs in the same channel (for example, A1, A2, and A3) can have different capacities.

Do not mix LRDIMMs with RDIMMs

For best performance, DIMMs in the same slot (for example, A1, B1, C1,

D1) should have the same capacity.

Do not mix LRDIMMs RDIMM s

DIMMs will run at the lowest speed of the DIMMs/CPUs installed

DIMMs will run at the lowest speed of the DIMMs/CPUs installed

DIMM Type

RDIMMs or LRDIMMs Do not mix DIMM types in a channel Do not mix DIMM types in a slot

1 DPC, 2 DPC, or 3 DPC

DIMMs per Channel (DPC)

See

Table 5 on page 16

for

valid LRDIMM and RDIMM 1 DPC, 2 DPC, and 3 DPC memory configurations

Notes . . .

1. Although you can have different DIMM capacities in the same slot, this will result in less than optimal performance. For optimal performance, all DIMMs in the same slot should be identical.

2. Only 2133-MHz DIMMs are currently available for the C220 M4 server.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

53

SUPPLEMENTAL MATERIAL

DIMM Population Order

Populate the DIMMs for a CPU according to

Table 32

.

Table 32 DIMM Population Order per CPU

Populate

CPU 2 Slots

E1

E1, F1

E1, F1, G1

E1, F1, G1, H1

E1, F1, G1,

E2, F2, G2

E1, F1, G1, H1,

E2, F2, G2, H2

E1, F1, G1, H1,

E2, F2, G2, H2,

E3, F3, G3, H3

54 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

Recommended Memory Configuration

This section explains the recommended DIMM population order rules for the C220 M4 server.

All DIMMs must be DDR4 DIMMs.

Do not mix:

— DIMMs with different clock rates in a channel

— RDIMMs and LRDIMMs

— ECC and non-ECC DIMMs

There are blue, black, and white DIMM slots. Populate blue slots first.

When DIMMs ranks are mixed in the same channel, always populate the highest rank DIMM in the blue DIMM slot and lower rank DIMM(s) in the black and white DIMM slots.

Many memory configurations are possible. For best results, follow

Table 33

when populating 2133-MHz

DIMMs for Intel Xeon E5-2600 v3 CPUs.

Table 33 Recommended Memory Configurations for Intel Xeon E5-2600 v3 CPUs (with 2133-MHz DIMMs)

1

Total

System

Memory

Size

Blue Slots

Slot 1

(A1,B1,

C1,D1)

CPU 1 DIMMs

Black Slots

Slot 2

(A2,B2,

C2,D2)

White Slots

Slot 3

(A3,B3,

C3,D3)

Blue Slots

Slot 1

(E1,F1,

G1,H1)

CPU 2 DIMMs

Black Slots

Slot 2

(E2,F2,

G2,H2)

White Slots

Slot 3

(E3,F3,

G3,H3)

DIMM Max

Speed

(MHz)

64 GB

4x8 GB — — 4x8 GB — — 2133

Total

DIMMs

8

128 GB

192 GB

256 GB

512 GB

768 GB

4x8 GB

4x16 GB

1x32 GB

4x16 GB

3x32 GB

4x16 GB

4x32 GB

4x32 GB

4x32 GB

4x8 GB

1x32 GB

4x8 GB

4x16 GB

4x32 GB

4x32 GB

4x32 GB

4x8 GB

4x16 GB

1x32 GB

4x16 GB

3x32 GB

4x16 GB

4x32 GB

4x32 GB

4x32 GB

4x8 GB

1x32 GB

4x8 GB

4x16 GB

4x32 GB

4x32 GB

4x32 GB

2133

2133

2133

1866

2133

2133

2133

2133

1866

4

16

6

16

16

8

8

16

24

Notes . . .

1. Rows marked in yellow indicate best performance.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

55

SUPPLEMENTAL MATERIAL

Additional DIMM Populations

The list in

Table 34

is not a complete list of all supported DIMM populations, but highlights common

configuration options.

1 x 8 GB

2 x 8 GB

1 x 16 GB

4 x 8 GB

2 x 16 GB

1 x 32 GB

8 x 8 GB

4 x 16 GB

2 x 32 GB

12 x 8 GB

6 x 16 GB

8 x 16 GB

4 x 32 GB

12 x 16 GB

6 x 32 GB

8 x 32 GB

12 x 32 GB

Table 34 Supported DIMM Configurations

CPU 1 DIMMs

Total DIMMs for CPU 1

CPU 1

Capacity

CPU 2 DIMMs

6

8

4

12

12

6

8

2

12

8

4

2

1

1

4

1

2

8 GB

16 GB

16 GB

32 GB

32 GB

32 GB

64 GB

64 GB

1 x 8 GB

2 x 8 GB

1 x 16 GB

4 x 8 GB

2 x 16 GB

1 x 32 GB

8 x 8 GB

4 x 16 GB

64 GB

96 GB

2 x 32 GB

12 x 8 GB

96 GB 6 x 16 GB

128 GB 8 x 16 GB

128 GB 4 x 32 GB

192 GB 12 x 16 GB

192 GB 6 x 32 GB

256 GB 8 x 32 GB

384 GB 12 x 32 GB

Total DIMMs for CPU 2

CPU 2

Capacity

6

8

4

12

12

6

8

2

12

8

4

2

1

1

4

1

2

8 GB

16 GB

16 GB

32 GB

32 GB

32 GB

64 GB

64 GB

64 GB

96 GB

96 GB

128 GB

128 GB

192 GB

192 GB

256 GB

384 GB

Total

Capacity for

2 CPUs

128 GB

192 GB

192 GB

256 GB

256 GB

384 GB

384 GB

512 GB

768 GB

16 GB

32 GB

32 GB

64 GB

64 GB

64 GB

128 GB

128 GB

56 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

RAID Details

The available RAID configurations are shown in this section.

(1) 1- and 2-CPU Configurations

Select one of these:

— The embedded software RAID 5 key upgrade option from

Table 6 on page 19

, or

— One Cisco 12G SAS Modular RAID controller from

Table 7 on page 20

, or

— One Cisco 9300-8E 12G SAS RAID controller from

Table 7 on page 20

— One Cisco 12G SAS Modular RAID controller from

Table 7 on page 20

and one Cisco

9300-8E 12G SAS RAID controller from

Table 7 on page 20

Select an appropriate optional RAID configuration listed in

Table 7 on page 20

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

57

SUPPLEMENTAL MATERIAL

RAID Option ROM (OPROM) Settings

The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option

ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in

Figure 8

.

Figure 8 Example BIOS Screen for OPROM

58 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

Embedded SATA RAID: Two SATA Controllers

The embedded SATA RAID controller hub is split into two controllers, SATA and sSATA (secondary SATA).

These two controllers are seen as separate RAID controllers in the Cisco IMC interface and are configurable separately.

The first SATA controller controls drives 1–4; the secondary sSATA controller controls drives 5–8.

When configuring RAID groups, you cannot create a group that spans more than four drives.

The first SATA controller can control a RAID group of up to four drives, consisting only of drives 1–4.

The secondary sSATA controller can control a RAID group of up to four drives, consisting only of drives 5–8. See

Figure 9

.

Figure 9 Embedded RAID Controller RAID Groups

HDD 01

HDD 04

HDD 02

HDD 05

HDD 03

HDD 06 HDD 07 HDD 08

SATA RAID Controller Hub

SATA sSATA

Each controller is listed separately in the BIOS. You can select the boot order of the controllers in the BIOS (use the Boot Options tab in the BIOS Setup Utility).

Note the following considerations:

The default setting for this embedded controller hub is SATA RAID 0, 1, and 10 support for up to eight SATA drives (in two groups of four drives).

You can upgrade this to support to SATA RAID 0, 1, 5, and 10 support for up to eight SATA drives (in two groups of four drives) by installing a RAID 5 key module on the motherboard.

When you order the server with this embedded controller, the controller is enabled in the BIOS.

You cannot downgrade from using a HW RAID controller card to using the SW RAID embedded controller.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

59

SUPPLEMENTAL MATERIAL

To Create a RAID Group

(1) While the server is booting, wait for the prompt and press function key F2 as shown in

Figure 10

.

Figure 10 Function Key F2 Prompt

In a few seconds, you will see the screen that allows you to set up a RAID group for the primary

SATA controller (see

Figure 11

).

Figure 11 Screen to Configure Primary SATA RAID Group

60 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

(2) Press Ctrl+M to start the RAID group creation process for the primary SATA controller (for drives 1-4, as shown in

Figure 9 on page 59

). Or, do nothing and wait for the next screen, which allows you to create a RAID group for the secondary SATA (sSATA) controller see

Figure 12

).

Figure 12 Screen to Configure Secondary SATA (sSATA) RAID Group

(3) Press Ctrl+M to start the RAID group creation process for the secondary SATA (sSATA) controller (for drives 5-8, as shown in

Figure 9 on page 59

).

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

61

SUPPLEMENTAL MATERIAL

Serial Port Details

The pinout details of the rear RJ-45 serial port connector are shown in

Figure 13

.

Figure 13 Serial Port (Female RJ-45 Connector) Pinout

Serial Port (RJ-45 Female Connector)

Pin Signal

6

7

4

5

8

1

2

3

RTS (Request to Send)

DTR (Data Terminal Ready)

TxD (Transmit Data)

GND (Signal Ground)

GND (Signal Ground)

RxD (Receive Data)

DSR (Data Set Ready)

CTS (Clear to Send)

62 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

Upgrade and Servicing-Related Parts

This section lists the upgrade and servicing-related parts you may need during the life of your server. Some of these parts are configured with every server, and some may be ordered when needed or may be ordered and kept on hand as spares for future use. See

Table 35

.Drive Blanking Panels

Table 35 Upgrade and Servicing-related Parts for UCS C220 M4 LFF Server

Spare Product ID (PID)

UCSC-HS-C220M4=

UCS-CPU-GREASE3=

UCS-CPU-LPCVR=

UCSX-HSCK=

UCSC-PCI-2A-220M4=

UCSC-PCI-2C-220M4=

UCSC-PCIF-01H=

UCSC-PCIF-01F=

N20-BBLKD

UCSC-MLOM-BLK=

UCSC-RAILF-M4=

UCSC-CMAF-M4=

UCSC-RAILB-M4=

UCSC-FAN-C220M4=

UCSC-BAFF-C220M4=

N20-BKVM=

UCSC-PSU-BLKP1U=

UCS-220CBLSR8=

UCS-220CBLMR8=

Description

Heat sink for UCS C220 M4 rack servers

M4 Server CPU thermal grease syringe - needed for heatsink seal

CPU load plate dust cover (for unpopulated CPU sockets)

UCS Processor Heat Sink Cleaning Kit For Replacement of CPU

C220 M4 PCIe Riser 1&2 Assy

C220 M4 PCIe Riser 3 (HBA)

PCIe Low Profile blanking panel for UCS C-Series Server

PCIe Full Height blanking panel for UCS C-Series Server

HDD blanking panel 1

MLOM blanking panel

Friction Rail Kit for C220 M4 rack servers

Reversible CMA for C220 M4 friction & ball bearing rail kits

Ball Bearing Rail Kit for C220 M4 and C220 M4 rack servers

C220 M4 Fan Module (one)

C220 M4 Air Baffle, Plastic Kit

KVM cable for Server console port

Power Supply Blanking Panel for C220 M4 servers

C220 M4 set of 2 SATA/SW RAID cables for 8HDD bckpln chassis

C220 M4 set of 2 RAID cntrlr cables for 8HDD bckpln chassis

Notes . . .

1. A drive blanking panel must be installed if you remove a disk drive from a UCS server. These panels are required to maintain system temperatures at safe operating levels, and to keep dust away from system components.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

63

SUPPLEMENTAL MATERIAL

Adding an Additional CPU (with CPU heat sink)

All Cisco UCS two CPU socket-capable servers can be upgraded from having one to having two CPUs configured. You will need to order and install a heat sink when adding any additional CPU to a server.

Instructions for installing the new CPU and heat sink can be found at the following link:

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html

See the section titled “Replacing CPUs and Heatsinks.”

Motherboard Lithium Battery

You can order a replacement motherboard battery. Installation instructions are found at this link:

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html

See the section titled “Replacing the Motherboard RTC Battery.”

Thermal Grease (with syringe applicator) for CPU to Heatsink Seal

Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink.

Instructions for applying thermal grease are found at:

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html

See the section titled “Replacing CPUs and Heatsinks.”

CAUTION: Use only the thermal grease specified for this server

(UCS-CPU-GREASE3=). This thermal grease comes in a white-tipped syringe and is to be used only in the C220 M4 and C240 M4 servers. Other servers use thermal grease in a blue-tipped syringe (UCS-CPU-GREASE=).

Thermal grease for other systems may have different thermal conductivity properties and may cause overheating if used in the C220 M4 or C240 M4 servers.

DO NOT use thermal grease available for purchase at any commercial electronics store. If these instructions are not followed, the CPU may overheat and be destroyed.

NOTE: When you purchase a spare CPU, the thermal grease with syringe applicator is included.

64 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

Air Baffle Replacement Kit

Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level. These baffles must always remain installed during server operation. The Air Baffle

Replacement Kit includes the air baffles needed for one UCS C220 M4 server.

CPU Heat Sink Cleaning Kit

The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process. Instructions for cleaning are found at the following link:

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html

See the section titled “Replacing CPUs and Heatsinks.”

NOTE: When you purchase a spare CPU, the CPU cleaning kit is included.

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

65

SUPPLEMENTAL MATERIAL

RACKS

The Cisco R42610 rack (see

Figure 14

) is certified for Cisco UCS installation at customer sites and is

suitable for the following equipment:

Cisco UCS B-Series servers and fabric interconnects

Cisco UCS C-Series and select Nexus switches

The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are

listed in

Table 36

.

Table 36 Cisco R42610 Rack Specifications

Parameter

Dimensions (H x W x D)

Dimensions (H x W x D) with packaging

Distance from front mounting rail to rear mounting rail

Weight

Weight with packaging

Side panels included

Equipment mounting capacity

Static load capacity

Standard Rack

78.74 x 24 x 43.38 in.

(2000 x 610 x 1102 mm)

89 x 33 x 47 in.

(2261 x 838 x 1194 mm)

29.2 in (741 mm)

299.83 lb (136 kg)

354 lb

(161 kg)

Yes

42RU

Dynamic load capacity

2100 lb

(954 kg)

Not applicable

Expansion Rack

78.74 x 23.58 x 43.38 in.

(2000 x 599 x 1102 mm)

89 x 33 x 47 in.

(2261 x 838 x 1194 mm)

29.2 in (741 mm)

231. 49 lb (105 kg)

284 lb

(129 kg)

No

42RU

2100 lb

(954 kg)

Not applicable

NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet.

66 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

Figure 14 Cisco R42610 Rack

SUPPLEMENTAL MATERIAL

Front view - door

Front view - door open

Front view - door removed

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

67

SUPPLEMENTAL MATERIAL

PDUs

Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection.

Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician.

With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.

The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.

The C-series severs accept the zero-rack-unit (0RU) PDU. See

Figure 15

).

Figure 15 Zero Rack Unit PDU (PID = RP208-30-2P-U-2)

1

2

Breakers

Ground connection

3

4

C19 plugs

C13 plugs

Cisco RP Series PDU models provide two 20-ampere (A) circuit breakers for groups of receptacles. The effects of a tripped circuit are limited to a receptacle group. Simply press a button to reset that circuit.

68 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

KVM CABLE

The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server.

The KVM cable ordering information is listed in

Table 37

.

Table 37 KVM Cable

Product ID (PID)

N20-BKVM=

PID Description

KVM cable for B-Series Blade Server console port

Figure 16 KVM Cable

1

2

Connector (to server front panel)

DB-9 serial connector

3

4

VGA connector (for a monitor)

Two-port USB connector (for a mouse and keyboard)

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

69

SUPPLEMENTAL MATERIAL

Motherboard USB and SD Ports, and RAID Card Backup Location

The C220 M4 SFF motherboard has a general-purpose USB socket, and two SD sockets as shown in

Figure 17

.

The mounting location for the RAID SuperCap data cache power backup module is also shown.

Figure 17 Motherboard USB and SD Ports and RAID Card SuperCap Location

2 3

4 5 6 7 8

PSU 2

FAN 6

FAN 5

FAN 4

SD 1

CPU 2

SD 2

PSU 1

9

1

PCIe Riser 2

PCIe Riser 1

10

11

12

FAN 3

FAN 2

FAN 1

CPU 1

13

17

1

2

3

4

5

8

9

6

7

Drives (SAS/SATA drives are hot-swappable)

Cooling fan modules (six)

SuperCap Power Module (RAID backup) mounting bracket

DIMM sockets on motherboard (24)

CPUs and heatsinks (up to two)

Embedded SATA RAID header for RAID 5 key

SD card bays on motherboard (two)

Internal USB 3.0 port on motherboard

Power supplies (up to two, hot-swappable when redundant as 1+1)

16 15 14

10

11

12

13

14

15

16

17

Trusted platform module (TPM) socket on motherboard (not visible in this view)

PCIe riser 2 (half-height PCIe slot 2)

PCIe riser 1 (full-height PCIe slot 1)

Modular LOM (mLOM) connector on chassis floor

Cisco modular RAID controller PCIe riser

(dedicated riser with horizontal socket)

Cisco modular RAID controller card

Embedded SATA RAID mini-SAS connectors on motherboard (not visible in this view)

RTC battery on motherboard

70 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Dimensions and Weight

Table 38 UCS C220 M4 Dimensions and Weight

Parameter

Height

Width

Depth

Front Clearance

Side Clearance

Rear Clearance

Weight

Maximum (8 HDDs, 2 CPUs, 16 DIMMs, 2 770 W power supplies)

Minimum (1 HDD, 1 CPU, 1 DIMM, 1 770 W power supply)

Bare (0 HDD, 0 CPU, 0 DIMM, 1 770 W power supply)

Value

1.7 in. (4.32 cm)

16.89 in. (43.0 cm) including handles:

18.98 in. (48.2 cm)

29.8 in. (75.6 cm) including handles:

30.98 in. (78.7 cm)

3 in. (76 mm)

1 in. (25 mm)

6 in. (152 mm)

37.9 lbs (17.2 kg)

30.5 lbs (13.8 kg)

29.2 lbs (13.2 kg)

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

71

TECHNICAL SPECIFICATIONS

Power Specifications

The general power specifications for the C220 M4 SFF server 770 W (AC) power supply are listed in

Table 39

.

Table 39 UCS C220 M4 SFF 770 W Power Supply Specifications

Description

AC input voltage

AC input frequency

Maximum AC input current

Maximum AC inrush current

Maximum output power for each power supply

Power supply output voltage

Power supply efficiency

Specification

100—240 VAC (nominal input voltage range)

90—64 VAC (min/max input voltage range)

47 to 63 Hz (single phase)

9.5 Amps maximum at 100 VAC

4.5 Amps maximum at 208 VAC

15 Amps peak at +35 degree C, 208V

(charging current for EMI-X capacitors is not considered to be inrush current)

For 90—264 VAC input range, the maximum rated output power is 770 watts per power supply

12 VDC ± 5%

CSCI Platinum, 230 VAC at 50 Hz:

Greater than:

90% at 20% load

94% at 50% load

91% at 100% load

In addition, 208 VAC at 60 Hz efficiency shall be greater than:

89% at 20% load

93% at 50% load

90% at 100% load

NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.

For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:

https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx

72 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

TECHNICAL SPECIFICATIONS

Environmental Specifications

The power specifications for the C220 M4 server are listed in

Table 40

.

Table 40 UCS C220 M4 SFF Environmental Specifications

Parameter

Temperature operating

Temperature nonoperating

Humidity (RH) operating

Humidity (RH) nonoperating

Altitude operating

Altitude nonoperating

Sound Power level, Measure

A-weighted per ISO7779 LWAd (Bels)

Operation at 73°F (23°C)

Sound Pressure level, Measure

A-weighted per ISO7779 LpAm (dBA)

Operation at 73°F (23°C)

Minimum

41 to 95° F (5 to 35° C) derate the maximum temperature by 1°C per every

1000 ft. (305 m) of altitude above sea level

–40 to 149°F (–40 to 65° C)

10 to 90%, non-condensing at 82° F (28° C)

5 to 93% at 82° F (28° C)

0 to 3,000 m (0 to 10,000 ft.)

0 to 12,192 m (0 to 40,000 ft.)

5.4

37

Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

73

TECHNICAL SPECIFICATIONS

Compliance Requirements

The regulatory compliance requirements for C-Series servers are listed in

Table 41

.

Table 41 UCS C-Series Regulatory Compliance Requirements

Parameter

Regulatory Compliance

Safety

EMC - Emissions

EMC - Immunity

Description

Products should comply with CE Markings per directives

2004/108/EC and 2006/95/EC

UL 60950-1 Second Edition

CAN/CSA-C22.2 No. 60950-1 Second Edition

EN 60950-1 Second Edition

IEC 60950-1 Second Edition

AS/NZS 60950-1

GB4943 2001

47CFR Part 15 (CFR 47) Class A

AS/NZS CISPR22 Class A

CISPR22 Class A

EN55022 Class A

ICES003 Class A

VCCI Class A

EN61000-3-2

EN61000-3-3

KN22 Class A

CNS13438 Class A

EN55024

CISPR24

EN300386

KN24

74 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project