advertisement
Spec Sheet
Cisco UCS C220 M4
High-Density Rack Server
(Small Form Factor Disk
Drive Model)
C
ISCO
S
YSTEMS
170 W
EST
T
ASMAN
D
R
S
AN
J
OSE
, CA, 95134
WWW
.
CISCO
.
COM
P
UBLICATION
H
ISTORY
R
EV
A.5
O
CTOBER
15, 2014
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . . . . . . . . . . . . . 23
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 29
STEP 10 ORDER RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . . . . . . . . 37
STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . 38
STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . 39
STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 40
OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Thermal Grease (with syringe applicator) for CPU to Heatsink Seal . . . . . . . . . . . . . . 64
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
2
Cisco UCS C220 M4 High-Density Rack Server Small Form Factor Disk Drive Model)
OVERVIEW
OVERVIEW
The Cisco® UCS C220 M4 SFF rack server is the newest 2-socket, 1U rack server from Cisco, designed for both performance and expandability over a wide range of storage-intensive infrastructure workloads from big data to collaboration.
The enterprise-class UCS C220 M4 SFF server extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U form factor with the addition of the Intel Xeon E5-2600 v3 series processor family that deliver significant performance and efficiency gains. In addition, the UCS C220 M4 SFF server provides 24
DIMM slots, up to 8 drives and 2 x 1 GbE LAN-on-motherboard (LOM) ports delivering outstanding levels of density and performance in a compact 1U package.
The C220 M4 SFF server includes a modular LAN on motherboard (mLOM) slot for installation of a Cisco
Virtual Interface Card (VIC) or third-party network interface card (NIC) without consuming a PCI slot in addition to 2 x 1 GbE embedded (on the motherboard). These features combine to provide outstanding levels of internal memory and storage expandability along with exceptional performance.
The Cisco UCS C220 M4 SFF server can be used standalone, or as part of the Cisco Unified Computing
System, which unifies computing, networking, management, virtualization, and storage access into a single integrated architecture enabling end-to-end server visibility, management, and control in both bare metal and virtualized environments.
Figure 1 Cisco UCS C220 M4 High-Density SFF Rack Server
Front View
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
3
DETAILED VIEWS
DETAILED VIEWS
Chassis Front View
shows the front view of the Cisco UCS C220 M4 High-Density SFF Rack Server.
Figure 2 Chassis Front View
4 5
6
7 9
8 10
2
HDD 02
HDD 05
HDD 03
HDD 06
3
HDD 07 HDD 08
HDD 01
HDD 04
1 11
3
4
1
2
5
Drives (up to eight 2.5-inch drives)
Pull-out asset tag
Operations panel buttons and LEDs
Power button/Power status LED
Unit identification button/LED
7
8
9
10
11
Fan status LED
Temperature status LED
Power supply status LED
Network link activity LED
KVM connector (used with KVM cable that provides two USB 2.0, one VGA, and one serial connector) 1
6
System status LED
Notes . . .
1. For more information about the KVM cable connection, see
4 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
Chassis Rear View
shows the external features of the rear panel.
Figure 3 Chassis Rear View
1 2
PCIe 01 PCIe 02
PSU 01 PSU 02 mLOM
3 4
5
6 7 8 9 10 11
1
2
PCIe riser 1/slot 1
PCIe riser 2/slot 2
7
8
Serial port (RJ-45 connector) 1
Two embedded (on the motherboard) Intel i350 GbE Ethernet controller ports
(LAN1, LAN2)
VGA video port (DB-15)
3
4
5
6
Modular LAN-on-motherboard (mLOM) card slot
Grounding-lug hole (for DC power supplies)
USB 3.0 ports (two)
1-Gb Ethernet dedicated management port
9
10
11
Rear unit identification button/LED
Power supplies (up to two, redundant as 1+1)
Notes . . .
1. For details of the serial port pinout, see
Embedded SATA RAID: Two SATA Controllers, page 59
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
5
BASE SERVER STANDARD CAPABILITIES and FEATURES
BASE SERVER STANDARD CAPABILITIES and FEATURES
lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory)
CONFIGURING the SERVER, page 9
.
Table 1 Capabilities and Features
Capability/Feature
Chassis
CPU
Chipset
Memory
Multi-bit Error
Protection
Embedded NIC
Expansion slots
Internal storage devices
Cisco Flexible Flash drives
Description
One rack unit (1RU) chassis
One or two Intel® Xeon E5-2600 v3 series processor family CPUs
Intel® C610 series chipset
24 slots for registered DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)
This server supports multi-bit error protection.
Two embedded (on the motherboard) Intel i350 GbE ports, supporting the following:
■
■
■
■
Pre-Execution Boot (PXE boot) iSCSI boot
Checksum and segmentation offload
NIC teaming
■
■
■
Riser 1:
• One full-height profile, 3/4-length slot with x24 connector and x16 lane
Riser 2:
• One half-height profile, half-length slot with x24 connector and x16 lane
Dedicated Cisco 12G SAS Modular RAID controller slot
• An internal slot is reserved for the 12G SAS Modular RAID controller card.
Drives are installed into front-panel drive bays that provide hot-pluggable access.
• Small Form Factor (SFF) drives. Up to eight 2.5-inch SAS or SATA hot-swappable hard disk drives (HDDs) or solid state drives (SSDs).
■
The server also contains one internal USB 2.0 port on the motherboard that you can use with a USB thumb drive for additional storage
■
UCS Storage Accelerators are also available. These PCIe flash storage devices provide independent high-speed storage.
The server supports up to two internal 32 GB or two internal 64 GB Cisco
Flexible Flash drives (SD cards).
6 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES
Table 1 Capabilities and Features (continued)
Capability/Feature
Video
Storage controller
Description
The Baseboard Management Controller provides video:
■
Matrox G200e video controller
■
Integrated 2D graphics core with hardware acceleration
■
Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at
60 Hz
■
■
24-bit color depth for all resolutions less than 1600x1200
256 MB video memory
■
Embedded Software RAID (6 Gbps)
• Embedded SATA-only RAID controller, supporting up to eight
SATA-only drives (RAID 0, 1), or
• Embedded Software RAID 5 key upgrade, supporting up to eight
SATA-only drives (RAID 0, 1, 5, 10)
■
Cisco 12G SAS Modular RAID controller card, supporting up to eight drives, which plugs into a dedicated RAID controller slot. This card can be purchased alone, or along with an onboard Flash-Backed Write Cache
(FBWC) upgrade option, as shown in the table below
WoL
Front Panel
RAID Card Version
UCSC-MRAID12G
1
UCSC-MRAID12G-1GB 2
UCSC-MRAID12G-2GB
2
UCSC-MRAID12G-4GB 2
Notes . . .
1. Base RAID controller card
2. FBWC option
Supported RAID Levels
JBOD, 0, 1, 10
JBOD, 0, 1, 5, 6, 10, 50, 60
JBOD, 0, 1, 5, 6, 10, 50, 60
JBOD, 0, 1, 5, 6, 10, 50, 60
Onboard FBWC
None
1 GB
2 GB
4 GB
■
Cisco 9300-8E 12G SAS PCIe external drive controller
• Cisco 12G SAS 9300-8e HBA with 8 external ports. SAS 3.0 compliant.
Provides eight external SAS ports. There is no cache or cache power backup.
The 1-Gb Base-T Ethernet LAN ports support the wake-on-LAN (WoL) standard.
A front panel controller provides status indications and control buttons
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
7
BASE SERVER STANDARD CAPABILITIES and FEATURES
Table 1 Capabilities and Features (continued)
Capability/Feature
Modular LAN on
Motherboard (mLOM) slot
Description
The mLOM slot can flexibly accommodate the following cards:
■
■
Cisco Virtual Interface Cards (VIC)
Quad Port Intel i350 1GbE RJ45 Network Interface Card (NIC)
NOTE: The four Intel i350 ports are provided on an optional card that plugs into the mLOM slot, and are separate from the two embedded (on the motherboard) LAN ports.
Interfaces
Power subsystem
ACPI
Fans
Integrated management processor
■
■
■
Rear panel
• One DB15 VGA connector
• One RJ45 serial port connector
• Two USB 3.0 port connectors
• One RJ-45 10/100/1000 Ethernet management port, using Cisco
Integrated Management Controller (CIMC) firmware
• Two Intel i350 embedded (on the motherboard) GbE LOM ports
• One flexible modular LAN on motherboard (mLOM) slot that can accommodate various interface cards
Front panel
• One KVM console connector (supplies two USB 2.0 connectors, one
VGA DB15 connector, and one serial port (RS232) RJ45 connector)
Various PCIe card ports (dependent on which cards are installed)
• Virtual Interface Card (VIC) ports
• Converged Network Adapter (CNA) ports
• Network Interface Card (NIC) ports
• Host Bus Adapter (HBA) ports
Up to two 770 W (AC) hot swappable power supplies. One is mandatory; one more can be added for 1 + 1 redundancy.
This server supports the advanced configuration and power interface (ACPI)
4.0 standard.
Chassis:
■
Six hot-swappable fans for front-to-rear cooling
BMC running Cisco Integrated Management Controller (CIMC) firmware.
Depending on your CIMC settings, the CIMC can be accessed through the
1-GbE dedicated management port, the 1-GbE LOM ports, or a Cisco virtual interface card (VIC).
8 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
CONFIGURING the SERVER
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Follow these steps to configure the Cisco UCS C220 M4 High-Density SFF Rack Server:
STEP 1 VERIFY SERVER SKU, page 10
STEP 4 SELECT RAID CONFIGURATION, page 18
STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 23
STEP 6 SELECT PCIe OPTION CARD(s), page 26
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 29
STEP 8 ORDER POWER SUPPLY, page 33
STEP 9 SELECT AC POWER CORD(s), page 34
STEP 10 ORDER RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 37
STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL), page 38
STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL), page 39
STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 40
STEP 14 SELECT OPERATING SYSTEM MEDIA KIT, page 43
STEP 15 SELECT SERVICE and SUPPORT LEVEL, page 44
OPTIONAL STEP - ORDER RACK(s), page 49
OPTIONAL STEP - ORDER PDU, page 50
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
9
CONFIGURING the SERVER
STEP 1 VERIFY SERVER SKU
Verify the product ID (PID) of the server as shown in
.
Table 2 PID of the C220 M4 High-Density SFF Rack Base Server
Product ID (PID)
UCSC-C220-M4S UCS C220 M4 SFF, no CPU, memory, HDD, SSD, power supply, SD cards, PCIe cards, or rail kit
Description
The Cisco UCS C220 M4 SFF server:
■
Does not include power supply, CPU, memory, hard disk drives (HDDs), solid-state drives
(SSDs), SD cards, rail kit, or plug-in PCIe cards.
NOTE: Use the steps on the following pages to configure the server with the components that you want to include.
10 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 2 SELECT CPU(s)
■
■
■
The standard CPU features are:
Intel Xeon E5-2600 v3 series processor family CPUs
Intel C610 series chipset
Cache size of up to 45 MB
Select CPUs
The available CPUs are listed in
.
Table 3 Available Intel CPUs: E5-2600 v3 Series Processor Family CPUs
Product ID (PID)
Intel
Number
Clock
Freq
(GHz)
Power
(W)
Cache
Size
(MB)
Cores QPI
UCS-CPU-E52699D
UCS-CPU-E52698D
UCS-CPU-E52697D
UCS-CPU-E52695D
UCS-CPU-E52690D
UCS-CPU-E52683D
UCS-CPU-E52680D
UCS-CPU-E52670D
UCS-CPU-E52667D
UCS-CPU-E52660D
UCS-CPU-E52650D
UCS-CPU-E52650LD
UCS-CPU-E52643D
UCS-CPU-E52640D
UCS-CPU-E52637D
UCS-CPU-E52630D
UCS-CPU-E52630LD
UCS-CPU-E52623D
UCS-CPU-E52620D
UCS-CPU-E52609D
2
E5-2699 v3
E5-2698 v3
E5-2697 v3
E5-2695 v3
E5-2690 v3
E5-2683 v3
E5-2680 v3
E5-2670 v3
E5-2667 v3
E5-2660 v3
E5-2650 v3
E5-2650L v3
E5-2643 v3
E5-2640 v3
E5-2637 v3
E5-2630 v3
E5-2630L v3
E5-2623 v3
E5-2620 v3
E5-2609 v3
2.30
2.30
2.60
2.30
2.60
2.00
2.50
2.30
3.20
2.60
2.30
1.80
3.40
2.60
3.50
2.40
1.80
3.00
2.40
1.90
145
135
145
120
135
120
120
120
135
105
105
65
135
90
135
85
55
105
85
85
45
40
35
35
30
35
30
30
20
25
25
30
20
20
15
20
20
10
15
15
18
16
14
14
12
14
12
12
8
10
10
12
6
8
4
8
8
4
6
6
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
8.0 GT/s
9.6 GT/s
8.0 GT/s
8.0 GT/s
8.0 GT/s
8.0 GT/s
6.4 GT/s
Notes . . .
1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.
2. The E5-2609 v3 CPU does not support Intel Hyper-Threading or Intel Turbo Boost technologies.
Highest
DDR4 DIMM
Clock
Support
(MHz) 1
2133
2133
2133
2133
2133
2133
2133
2133
2133
2133
2133
1866
2133
1866
2133
1866
1866
1866
1866
1600
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
11
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU configurations:
■
Select any one CPU listed in
(2) 2-CPU Configurations:
■
Select two identical CPUs from any one of the rows of
.
Caveats
■
■
You can select either one processor or two identical processors.
For optimal performance, select DIMMs with the highest clock speed for a given processor
). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result.
12 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 3 SELECT MEMORY
Figure 4
The standard memory features are:
■
■
DIMMs
— Clock speed: 2133 MHz
— Ranks per DIMM: 1, 2, or 4
— Operational voltage: 1.2 V
— Registered ECC DDR4 DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)
Memory is organized with four memory channels per CPU, with up to three DIMMs per channel, as shown in
.
C220 M4 SFF Memory Organization
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
13
CONFIGURING the SERVER
Select DIMMs and Memory Mirroring
Select the memory configuration and whether or not you want the memory mirroring option.
The available memory DIMMs and mirroring option are listed in
.
NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored
DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data.
Table 4 Available DDR4 DIMMs
Product ID (PID) PID Description
DIMM Options
UCS-ML-1X324RU-A 32GB DDR4-2133-MHz LRDIMM/PC3-17000/quad rank/x4
UCS-MR-1X162RU-A 16GB DDR4-2133-MHz RDIMM/PC3-17000/dual rank/x4
UCS-MR-1X081RU-A 8GB DDR4-2133-MHz RDIMM/PC3-17000/single rank/x4
Memory Mirroring Option
N01-MMIRROR Memory mirroring option
Approved Configurations
Voltage
1.2 V
1.2 V
1.2 V
Ranks
/DIMM
4
2
1
(1) 1-CPU configuration without memory mirroring:
■
Select from 1 to 12 DIMMs. Refer to
Memory Population Rules, page 53
, for more detailed information.
14 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
(2) 1-CPU configuration with memory mirroring:
■
Select 2, 4, 6, 8, or 12 identical DIMMs. The DIMMs will be placed by the factory as shown in the following table.
Total
Number of
DIMMs
2
4
6
1
8
12
CPU 1 DIMM Placement in Channels
(for identical dual-rank DIMMs for 3DPC or identical quad-rank DIMMs for 2DPC)
Blue Slots
(A1, B1)
(A1,B1); (C1,D1)
(A1,B1,C1)
(A1,B1); (C1,D1)
(A1,B1); (C1,D1)
Notes . . .
1. Not recommended (for performance reasons)
Black Slots
—
—
(A2,B2,C2)
(A2,B2); (C2,D2)
(A2,B2); (C2,D2)
White Slots
—
—
(A3,B3); (C3,D3)
■
Select the memory mirroring option (N01-MMIRROR) as shown in
(3) 2-CPU configuration without memory mirroring:
■
Select from 1 to 12 DIMMs per CPU. Refer to
Memory Population Rules, page 53
, for more detailed information.
(4) 2-CPU configuration with memory mirroring:
■
Select 2, 4, 6, 8, or 12 identical DIMMs per CPU. The DIMMs will be placed by the factory as shown in the following table.
Number of
DIMMs per CPU
6
2
4
8
1
12
CPU 1 DIMM Placement in Channels
(for identical dual-rank DIMMs for 3DPC or identical quad-rank DIMMs for 2DPC)
Blue Slots
(A1, B1)
Black Slots
—
White Slots
—
(A1,B1);
(C1,D1)
—
(A1,B1, C1); (A2, B2, C2)
—
—
(A1,B1);
(C1,D1)
(A1,B1);
(C1,D1)
(A2,B2);
(C2,D2)
(A2,B2);
(C2,D2)
—
(A3, B3)
(C3, D3)
Notes . . .
1. Not recommended (for performance reasons)
CPU 2 DIMM Placement in Channels
(for identical dual-rank DIMMs for 3DPC or identical quad-rank DIMMs for 2DPC)
Blue Slots
(E1, F1)
Black Slots
—
White Slots
—
(E1,F1);
(G1,H1)
(E1,F1, G1);
—
(E2, F2, G2)
—
—
(E1,F1);
(G1,H1)
(E1,F1);
(G1,H1)
(E2,F2);
(G2,H2)
(E2,F2);
(G2,H2)
—
(E3,F3);
(G3,H3)
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
15
CONFIGURING the SERVER
■
Select the memory mirroring option (N01-MMIRROR) as shown in
NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the server.
Caveats
■
System speed is dependent on how many DIMMs are populated per channel and the CPU
DIMM speed support. See
for details.
Table 5 DIMM Memory Speeds with Different CPUs
1600-MHz Capable CPU 1866-MHz Capable CPU 2133-MHz Capable CPU
DIMM Speed DPC
2133 DIMM
1
LRDIMM
(QR)
1DPC 1600
2DPC 1600
3DPC 1600
RDIMM (DR,
SR)
1600
1600
1600
LRDIMM
(QR)
1866
1866
1600
RDIMM (DR,
SR)
1866
1866
1600
LRDIMM
(QR)
2133
2133
1866
RDIMM (DR, SR)
2133
2133
1866 (16 GB DIMMs)
1600 (8 GB DIMMs)
Notes . . .
1. 2133-MHz DIMMs are the only offered and supported DIMMs for the C220 M4 server
■
■
■
■
■
■
The C220 M4 server supports four different memory reliability, availability, and serviceability (RAS) modes:
— Independent Channel Mode
— Mirrored Channel Mode
— Lockstep Channel Mode
Below are the system level RAS Mode combination limitations:
— Mixing of Independent and Lockstep channel mode is not allowed per platform.
— Mixing of Non-Mirrored and Mirrored mode is not allowed per platform.
— Mixing of Lockstep and Mirrored mode is not allowed per platform.
Do not mix RDIMMs with LRDIMMs
Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel
Do not mix quad-rank DIMMs with single- or dual-rank DIMMs in the same channel
For best performance, observe the following:
— DIMMs with different timing parameters can be installed on different slots within the same channel, but only timings that support the slowest DIMM will be applied to all.
16 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
■
■
■
■
■
■
As a consequence, faster DIMMs will be operated at timings supported by the slowest
DIMM populated.
— When one DIMM is used, it must be populated in DIMM slot 1 (farthest away from the
CPU) of a given channel.
— When single, dual or quad rank DIMMs are populated for 2DPC or 3DPC, always populate the higher number rank DIMM first (starting from the farthest slot). For a
3DPC example, first populate with quad-rank DIMMs in the DIMM slot 1. Then dual-rank DIMMs in the DIMM 2 slot. Then single-rank DIMMs in the DIMM 3 slot.
DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically.
When using mirroring, DIMMs must be installed in identical pairs across paired DDR4 buses.
That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical. However, the DIMMs used in channels A and B can be different from those in channels C and D.
Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must be even for mirroring).
Non-ECC DIMMs are not supported.
Pairs of DIMMs (A1/B1, A2/B2, etc) MUST be the exact same (same PID, rev, DIMM loading order)
Cisco memory from previous generation servers (DDR3) is not compatible with this server
For more information regarding memory, see
.
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
17
CONFIGURING the SERVER
STEP 4 SELECT RAID CONFIGURATION
NOTE: If you do not select a Cisco 12G SAS Modular RAID controller or the embedded software RAID 5 key upgrade, you will have two SATA-only RAID controllers that support up to two sets of four SATA-only drives (RAID 0, 1).
The embedded RAID controller hub is split into two controllers, SATA and sSATA
(secondary SATA). These two controllers are seen as separate RAID controllers in the
Cisco IMC interface and are configurable separately. For more details, see
Embedded SATA RAID: Two SATA Controllers, page 59
.
NOTE: When creating each RAID volume, follow these guidelines:
■
Use the same capacity for each drive in each RAID volume
■
Use either all SAS drives or all SATA drives in each RAID volume
■
Use either all HDDs or all SSDs in each RAID volume
■
The embedded SATA only RAID controllers have two ports and each port can control 4 drives, for 8 drives total. However, each set of 4 SATA drives for a port must be in separate RAID volumes. You cannot mix drives across ports to create a
RAID volume. For more details, see
NOTE: The number of RAID groups (virtual drives) supported per controller is as follows:
■
■
Embedded RAID = 8
Cisco 12G SAS Modular RAID controller = 64
The RAID controller choices are:
(1) Embedded Software RAID 5 Key Upgrade (on motherboard)
NOTE: The RAID configuration options listed in
are not available if you choose the embedded software RAID 5 key upgrade (in this case, you must configure RAID yourself using separate software).
(2) Cisco 12G SAS Modular RAID Controller
The C220 M4 server has a dedicated RAID controller slot on the motherboard that accommodates the Cisco 12G SAS Modular RAID controller for internal HDDs/SSDs. Cisco can provide factory-configured RAID setting options depending on the RAID controller chosen and the number of HDDs/SSDs ordered. Factory-configured RAID level options are listed with each RAID card description.
18 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Select RAID Options
■
■
Select one of the following:
■
Embedded software RAID 5 key upgrade option for internal drives (see
), or
Cisco 12G SAS modular RAID controller for internal drives plus optional flash-backed write cache (FBWC) (see
), or
Dual controllers:
— One Cisco 12G SAS modular RAID controller for internal drives plus optional flash-backed write cache (FBWC), and
— One Cisco 9300-8E 12G SAS controller for external drives
NOTE: The Cisco 12G SAS modular RAID controller can be ordered with or without an optional FBWC.
The FBWC option backs up the RAID controller write cache.
The
FBWC is available in 1 GB, 2 GB, or 4 GB sizes. See
NOTE: For all valid combinations of embedded RAID and internal/external RAID
.
shows the product ID for the C220 M4 server entry-level RAID solution. This RAID option is accomplished with embedded software that supports a limited number of drives, operating systems, and virtualized environments. For a more comprehensive enterprise RAID solution, choose the Cisco 12G SAS
modular RAID controller listed in
Table 6 Entry Level RAID Solution
Product ID (PID) PID Description
Embedded Software RAID 5 Key Upgrade
UCSC-SWRAID5 Embedded Software RAID 5 key upgrade, consisting of a storage controller unit
(SCU) module that plugs into a 2-pin header on the motherboard, supporting
up to eight internal SATA only drives. See
. This module upgrades the embedded software RAID
controller options to add RAID 5. This option supports RAID 0, 1, 5, 10 and operates at 6 Gbps. Operating systems supported are Windows and Linux only
(no VMware support).
NOTE: VMware ESX/ESXi or any other virtualized environments are not supported for use with the embedded MegaRAID controller. Hypervisors such as Hyper-V, Xen, or
KVM are also not supported for use with the embedded MegaRAID controller
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
19
CONFIGURING the SERVER
Table 7 RAID Controller Options
Product ID (PID) PID Description
RAID Controller for Internal Drives
Note that if the following Cisco 12G SAS modular RAID controller is selected, it is factory-installed in a dedicated internal Cisco Modular RAID controller PCIe slot.
UCSC-MRAID12G Cisco 12G SAS Modular Raid Controller
■
Supports up to 8 internal SAS drives.
■
Supports JBOD, RAID 0, 1, 10
Flash-Backed Write Cache (FBWC) Upgrade Options for Cisco 12G SAS Modular RAID controller
UCSC-MRAID12G-1GB
UCSC-MRAID12G-2GB
1 GB FBWC, which includes a 1 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 5, 6, 10, 50, and 60.
2 GB FBWC, which includes a 2 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 5, 6, 10, 50, and 60.
UCSC-MRAID12G-4GB 4 GB FBWC, which includes a 4 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 5, 6, 10, 50, and 60.
SAS HBA for External JBOD Attach
Note that the Cisco 12G SAS 9300-8e, if selected, is installed by default in slot 1. Two SFF8644 mini-SAS x4 connectors on this card are accessible at the rear of the chassis.
UCSC-SAS9300-8E Cisco 12G SAS 9300-8e SAS HBA for external JBOD attach
■
Supports external JBOD using X4 and X8 wide SAS ports.
NOTE: For Cisco 12G SAS 9300-8e HBA external drive enclosure support, see the enclosure section of the compatibility list at the following link:
http://tinyurl.com/pp83xyk
Customers should contact their storage vendor for technical support related to external JBOD enclosures.
SuperCap Option
UCSC-MRAID-SC= Spare SuperCap for Cisco 12G SAS Modular RAID, including all cables. This is a spare SuperCap. It is the exact same SuperCap that ships with the FBWC options listed earlier in this table and can be used as a replacement or upgrade part.
20 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 7 RAID Controller Options (continued)
Product ID (PID) PID Description
RAID Configuration Options (not available for embedded RAID 5 key upgrade)
R2XX-SRAID0 Enable Single Disk Raid 0 Setting
R2XX-RAID0
R2XX-RAID1
R2XX-RAID5
R2XX-RAID6
R2XX-RAID10
Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity.
Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity.
Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity.
Factory preconfigured RAID option
Enable RAID 10 Setting. Requires a even number of drives (minimum of four drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown in
Approved Configurations
The C220 M4 SFF server has an 8-drive backplane.
■
■
■
The embedded software RAID 5 upgrade key option supports up to eight internal SATA only drives.
The Cisco 12G SAS Modular RAID controller supports up to eight internal drives.
The Cisco 12G SAS 9300-8e PCIe external drive controller supports up to 8 external SAS+SATA ports
NOTE: If you do not select a Cisco 12G SAS Modular RAID controller, or the embedded software RAID 5 key upgrade option, you will have an embedded
SATA-only RAID controller that supports up to eight SATA-only drives (RAID 0, 1).
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
21
CONFIGURING the SERVER
for a summary of the supported RAID configuration options.
Table 8 Supported RAID Configurations
Server # CPUs Embedded RAID
Cisco 12G SAS
Modular RAID
Controller 1
External PCIe
Controller 2
# Drives
Supported
C220 M4 SFF
8 HDD
C220 M4 SFF
8 HDD
C220 M4 SFF
8 HDD
C220 M4 SFF
8 HDD
C220 M4 SFF
8 HDD
C220 M4 SFF
8 HDD
C220 M4 SFF
8 HDD
C220 M4 SFF
8 HDD
1
1
1
1
2
2
2
2
Enabled
Not allowed
Not allowed
Not allowed
Enabled
Not allowed
Not allowed
Not allowed
Not allowed
Installed on Motherboard
Card absent
Installed
Installed on Motherboard
Card absent
Not allowed
Card absent
Installed slot 1 on Motherboard Installed slot 1
Not allowed
Installed on Motherboard
Not allowed
Card absent
Installed any slot
Installed any slot
8 internal SATA only
8 internal
0 internal
1024 external
8 internal
1024 external
8 internal SATA only
8 internal
0 internal
1024 external
8 internal
1024 external
Notes . . .
1. If you want to boot from a device other than the Cisco 12G SAS Modular RAID controller, you can leave the card installed. Just disable the OPROM for its slot, and the system will boot even with the card installed.
2. External PCIe drive controller card is the Cisco 12G SAS 9300-8e and can be installed simultaneously with the
Cisco 12G SAS Modular RAID controller.
Caveats
■
■
■
A maximum of one Cisco 12G SAS 9300-8e can be installed, and it can be installed only in slot 1. Note that a Storage Accelerator also can only be installed in slot 1. Therefore, the system can support either one storage accelerator card or one Cisco 12G SAS 9300-8e, but not both at the same time.
For the Cisco 12G SAS Modular RAID controller, you can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is preconfigured at the factory. The RAID level you choose must be an available RAID choice for the controller selected. RAID levels 50 and
60 are supported, although they are not available as configuration options.
A system supports up to eight SATA-only drives if no embedded software RAID 5 key upgrade controller or Cisco 12G SAS Modular RAID controller is chosen.
NOTE: For more important information regarding RAID support, see
RAID Option ROM (OPROM) Settings, page 58
.
22 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES
(SSDs)
■
■
■
The standard disk drive features are:
2.5-inch small form factor
Hot-pluggable
Drives come mounted in sleds
Select Drives
The available drives are listed in
Table 9 Available Hot-Pluggable Sled-Mounted HDDs and SSDs
Product ID (PID) PID Description
HDDs (15K RPM)
UCS-HD600G15KS2-E 600 GB 6 Gbps SAS 15K RPM SFF HDD
UCS-HD450G15KS2-E 450 GB 6 Gbps SAS 15K RPM SFF HDD
UCS-HDD300GI2F105 300 GB 6 Gbps SAS 15K RPM SFF HDD
HDDs (10K RPM)
UCS-HD12T10KS2-E
A03-D300GA2
HDDs (7.2K RPM)
1.2 TB 6 Gbps SAS 10K RPM SFF HDD
UCS-HDD900GI2F106 900 GB 6 Gbps SAS 10K RPM SFF HDD
A03-D600GA2 600 GB 6 Gbps SAS 10K RPM SFF HDD
300 GB 6 Gbps SAS 10K RPM SFF HDD
UCS-HD1T7KS2-E
A03-D1TBSATA
1 TB 6 Gbps SAS 7.2K RPM SFF HDD
1 TB 6 Gbps SATA 7.2K RPM SFF HDD
Drive
Type
Capacity
SAS
SAS
SAS
600 GB
450 GB
300 GB
SAS
SAS
SAS
SAS
1.2 TB
900 GB
600 GB
300 GB
SAS 1 TB
SATA 1 TB
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
23
CONFIGURING the SERVER
Table 9 Available Hot-Pluggable Sled-Mounted HDDs and SSDs (continued)
Product ID (PID) PID Description
Drive
Type
Capacity
Enterprise Performance SSDs (high endurance, supports up to 10 FDWP (full drive writes per day)) 1
UCS-SD16T12S2-EP 1.6 TB Enterprise Performance 12 Gbps SAS eMLC SSD (Toshiba) SAS
UCS-SD800G0KS2-EP 800 GB Enterprise Performance 6 Gbps SAS eMLC SSD (Samsung) SAS
UCS-SD400G12S2-EP 400 GB Enterprise Performance 12 Gbps SAS eMLC SSD (Toshiba) SAS
1.6 TB
800 GB
400 GB
UCS-SD400G0KS2-EP 400 GB Enterprise Performance 6 Gbps SAS eMLC SSD (Samsung) SAS
UCS-SD200G0KS2-EP 200 GB Enterprise Performance 6 Gbps SAS eMLC SSD (Samsung) SAS
400 GB
200 GB
Enterprise Value SSDs (endurance of up to 1 FDWP (full drive write per day)) 2
UCS-SD960G0KS2-EV 960 GB 2.5 inch Enterprise Value 6 Gbps SAS SSD
UCS-SD480G0KS2-EV 480 GB 2.5 inch Enterprise Value 6 Gbps SAS SSD
UCS-SD240G0KS2-EV 240 GB 2.5 inch Enterprise Value 6 Gbps SAS SSD
UCS-SD120G0KS2-EV 120 GB 2.5 inch Enterprise Value 6 Gbps SAS SSD
SATA 960 GB
SATA 480 GB
SATA 240 GB
SATA 120 GB
Notes . . .
1. Targeted for IO write centric applications. Supports endurance of 10 FDWP (full drive writes per day). Target applications are caching, online transaction processing (OLTP), data warehousing, and virtual desktop infrastructure (VDI).
2. Targeted for IO read centric applications. Supports endurance of 1 FDWP (full drive writes per day). Target applications are boot, streaming media, and collaboration.
NOTE: When creating each RAID volume, follow these guidelines:
■
Use the same capacity for each drive in each RAID volume
■
Use either all SAS drives or all SATA drives in each RAID volume
■
Use either all HDDs or all SSDs in each RAID volume
■
The embedded SATA only RAID controllers have two ports and each port can control 4 drives, for 8 drives total. However, each set of 4 SATA drives for a port must be in separate RAID volumes. You cannot mix drives across ports to create a
RAID volume. For more details, see
24 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Approved Configurations
(1) Embedded RAID or Cisco 12G SAS Modular RAID Controller
■
■
■
If you have not selected an embedded software RAID 5 key upgrade option (UCSC-SWRAID5) or a Cisco 12G SAS Modular RAID controller for internal drives, you will have an SATA-only
RAID controller that supports up to eight SATA-only drives (RAID 0, 1). Select up to eight
SATA-only drives from
.
If you selected an embedded RAID 5 key upgrade option (supports RAID 0, 1, 5, and 10),
select up to eight SATA drives listed in
If you selected a Cisco 12G SAS Modular RAID controller for internal HDDs/SSDs, you have the following options:
— Cisco 12G SAS Modular RAID controller with no FBWC option (supports JBOD, RAID 0,
1, 10)
— Cisco 12G SAS Modular RAID controller with FBWC option (supports JBOD, RAID 0, 1,
5, 10, 50, and 60)
— For either option, select up to eight SAS drives listed in
SELECT RAID CONFIGURATION, page 18
Caveats
■
You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all
SSDs in their own RAID volume
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
25
CONFIGURING the SERVER
STEP 6 SELECT PCIe OPTION CARD(s)
■
■
■
■
■
■
The standard PCie card offerings are:
Modular LAN on Motherboard (mLOM)
Virtual Interface Cards (VICs)
Network Interface Cards (NICs)
Converged Network Adapters (CNAs)
Host Bus Adapters (HBAs)
UCS Storage Accelerators
Select PCIe Option Cards
The available PCIe option cards are listed in
Table 10 Available PCIe Option Cards
Product ID (PID) PID Description
Modular LAN on Motherboard (mLOM) 1
UCSC-MLOM-CSC-02 Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+
Virtual Interface Cards (VICs)
UCSC-PCIE-CSC-02 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA
UCSC-PCIE-C10T-02 Cisco VIC 1225T Dual Port 10GBaseT CNA
Network Interface Cards (NICs)
1 Gb NICs
UCSC-PCIE-IRJ45 Intel i350 Quad Port 1Gb Adapter
10 Gb NICs
N2XX-AIPCI01
UCSC-PCIE-ITG
Intel X520 Dual Port 10Gb SFP+ Adapter
Intel X540 Dual Port 10GBase-T Adapter
Card
Height
N/A
Half
Half
Half
Half
Half
26 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 10 Available PCIe Option Cards (continued)
Product ID (PID) PID Description
Card
Height
10 Gb Converged Network Adapters (CNAs)
UCSC-PCIE-E14102 Emulex OCe14102-UX dual-port 10 GbE FCoE CNA
Host Bus Adapters (HBAs)
N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA
UCSC-PCIE-Q2672
N2XX-AEPCI05
UCSC-PCIE-E16002
Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics
Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA
Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics
UCS Storage Accelerators
2
UCSC-F-FIO-1000PS
UCSC-F-FIO-1300PS
UCSC-F-FIO-2600PS
UCSC-F-FIO-5200PS
UCSC-F-FIO-3200SS
UCSC-F-FIO-6400SS
UCS 1000GB Fusion ioMemory3 PX Performance line for C-Series
UCS 1300GB Fusion ioMemory3 PX Performance line for C-Series
UCS 2600GB Fusion ioMemory3 PX Performance line for C-Series
UCS 5200GB Fusion ioMemory3 PX Performance line for C-Series
UCS 3200GB Fusion ioMemory3 SX Scale line for C-Series
UCS 6200GB Fusion ioMemory3 SX Scale line for C-Series
Half
Half
Half
Half
Half
Half
Half
Half
Full
Half
Full
Notes . . .
1. The mLOM cards do not plug into any of the riser 1 or riser 2 card slots; instead, they plug into a connector inside the server chassis.
2. A maximum of one storage accelerator card is supported and it must be installed in slot 1 only. Note that the
Cisco 12G SAS 9300-8e also can only be installed in slot 1.
Approved Configurations
(1) 1-CPU Systems
■
You can select up to one PCie option card (slot 1 for 1-CPU systems) listed in
.
(2) 2-CPU Systems
■
You can select up to two PCie option cards (slots 1 and 2 for 2-CPU systems) listed in
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
27
CONFIGURING the SERVER
Caveats
■
■
■
■
■
A maximum of one storage accelerator card is supported and it must be installed in slot 1 only. Note that the Cisco 12G SAS 9300-8e also can only be installed in slot 1. Therefore, the system can support either one storage accelerator card or one Cisco 12G SAS 9300-8e, but not both at the same time.
For 1-CPU systems:
— Only the full-height PCIe slot on riser 1 (slot 1) is supported
— Only a single plug-in PCIe VIC card is supported and must be installed in slot 1 (the full-height slot). However, in addition to the one PCIe VIC card, you can also choose to install an mLOM VIC card.
— If any of the Storage Accelerator cards are installed, they can be installed only in slot 1.
For 2-CPU systems:
— Both PCIe slots (slots 1 and 2) are supported
— Only a single plug-in PCIe VIC card is supported and it must be installed in slot 1 (the full height slot). However, in addition to the one PCIe VIC card, you can also choose an mLOM VIC card.
— If any of the Storage Accelerator cards are installed, they can be installed only in slot 1.
Other considerations for the Cisco VIC 1225/1227/1225T cards:
— VIC 1225 and VIC 1227 Supports 10G SFP+ optical and copper twinax connections
— VIC 1225T Supports RJ45 Category 6 or better twisted pair cable connections
— The server supports installation of one PCIe Cisco VIC 1225/1225Tcard and it is supported only in PCIe slot 1.
— For the Cisco UCS VIC1225, requires that the server has CIMC firmware version 1.4(6) or later installed and VIC firmware of 2.1(0) or later. For the Cisco UCS VIC1225T, requires that the server has CIMC firmware version 1.5(1) or later installed and VIC firmware of 2.1(1) or later.
To help ensure that your operating system is compatible with the card you have selected, or to see additional cards that have been qualified to work with the UCS C220 M4 server, but are not sold on the Cisco pricelist, check the Hardware Compatibility List at this URL:
http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html
28 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES
Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server.
Choose Optional Twinax Cables
lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality.
Table 11 Available Twinax Cables
Product ID (PID)
SFP-H10GB-CU1M
SFP-H10GB-CU3M
SFP-H10GB-CU5M
SFP-H10GB-ACU7M
SFP-H10GB-ACU10M
PID Description
10GBASE-CU SFP+ Cable (1 M)
10GBASE-CU SFP+ Cable (3 M)
10GBASE-CU SFP+ Cable (5 M)
10GBASE-CU SFP+ Cable (7 M)
10GBASE-CU SFP+ Cable (10 M)
Approved Configurations
(1) Choose Up to Two Twinax Cables for Each Network Card Ordered
■
You may choose one or two twinax cables for each compatible PCIe network card ordered.
The cables can be different lengths; however, you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment.
Choose Optional SFP Modules
Optical Cisco SFP+ modules are listed in
Table 12 Available SFP Modules
Product ID (PID)
SFP-10G-SR
DS-SFP-FC8G-SW
PID Description
10GBASE-SR SFP+ Module
850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
8 Gbit SFP+ Module
850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
29
CONFIGURING the SERVER
Approved Configurations
(1) Choose Up to Two SFP+ Modules for Each Network Card Ordered
■
You may choose one or two SFP+ optical modules cables for each compatible PCIe network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available.
See the
for typical SFP+ and twinax connections to the network cards.
Caveats
Check the table on the following page for compatibility between the PCIe network cards and
SFPs or twinax cables.
NOTE: The table shows all PCIe network cards for all C-series servers. Not all of the cards shown in the table are supported in this server. The intent of the table is to show compatibility between cards and twinax cables or SFPs.
30 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 13 PCIe Card Compatibility
PCIe Cards
Converged Network Adapters (CNAs)
UCSC-PCIE-BSFP
(Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI)
UCSC-PCIE-CSC-02
(Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)
UCSC-PCIE-C10T-02
(Cisco VIC 1225T Dual Port 10GBaseT CNA)
UCSC-PCIE-C40Q-02
(Cisco VIC 1285 Dual Port 40Gb QSFP CNA)
UCSC-PCIE-C40Q-03
(Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA)
UCSC-PCIE-ESFP
(Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA))
UCSC-PCIE-QSFP
(QLogic QLE8242-CU dual-port 10 GbE FCoE CNA)
UCSC-PCIE-B3SFP
(Broadcom 57810 10Gb A-FEX SFP+
UCSC-PCIE-Q8362
(Qlogic QLE8362 dual-port 10 GbE FCoE CNA)
UCSC-PCIE-E14102
(Emulex OCe14102-UX dual-port 10 GbE FCoE CNA)
Network Interface Cards (NICs)
N2XX-ABPCI01-M3
(Broadcom 5709 Dual-Port Ethernet PCIe Adapter for M3
Servers)
N2XX-ABPCI03-M3
(Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3
Servers
N2XX-AIPCI01
(Intel X520 Dual Port 10Gb SFP+ Adapter)
UCSC-PCIE-ITG
(Intel X540 Dual Port 10GBase-T Adapter)
UCSC-PCIE-IRJ45
(Intel i350 Quad Port 1Gb Adapter
UCSC-PCIE-BTG
(Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI)
Host Bus Adapters (HBAs)
N2XX-AEPCI03
(Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA
N2XX-AEPCI05
(Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA)
N2XX-AQPCI03
(QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA)
Twinax
Cables
Cisco SFP Modules
SFP-10G-SR DS-SFP-FC8G-SW
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
No
No
No
Yes
Yes
Yes
No
Use RJ45 Ethernet cable
No
Use RJ45 Ethernet cable
No
1
1
Use Qlogic SFP
Use Qlogic SFP
Use Intel SFP
No
No
No
No
No
No
No
No
No
No
No
Preinstalled - do not change SFP
Preinstalled - do not change SFP
Preinstalled - do not change SFP
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
31
CONFIGURING the SERVER
Table 13 PCIe Card Compatibility (continued)
PCIe Cards
N2XX-AQPCI05
(QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA)
UCSC-PCIE-Q2672
(Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics)
UCSC-PCIE-E16002
(Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics)
Notes . . .
1. This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable.
Twinax
Cables
Cisco SFP Modules
SFP-10G-SR DS-SFP-FC8G-SW
No Preinstalled - do not change SFP
No
No
Preinstalled - do not change SFP
Preinstalled - do not change SFP
Figure 5 Network Card Connections
32 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 8 ORDER POWER SUPPLY
The C220 M4 SFF server accommodates two power supplies. A lightly loaded server can operate from one 770 W power supply. A fully loaded server might need to be powered with two 770 W power supplies (see
).
Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on):
https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
Table 14 Power Supply PIDs
Product ID (PID)
UCSC-PSU1-770W
PID Description
770 W power supply
NOTE: In a two power supply server, both power supplies must be identical.
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
33
CONFIGURING the SERVER
STEP 9 SELECT AC POWER CORD(s)
, select the appropriate AC power cords. You can select a minimum of no power
cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
Table 15 Available Power Cords
Product ID (PID) PID Description
R2XX-DMYMPWRCORD No power cord (dummy PID to allow for a no power cord option)
CAB-N5K6A-NA Power Cord, 200/240V 6A, North
America
Images
Not applicable
Plug: NEMA 6-15P
Cordset rating: 10 A, 250 V
Length: 8.2 ft
Connector:
IEC60320/C13
CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft
CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L,
C13/C14, 10A/250V
CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR,
2 Meter, C13/C14,10A/250V
CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6
0320/C13, 3.0M
34 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 15 Available Power Cords
Product ID (PID)
SFS-250V-10A-AR
CAB-9K10A-AU
PID Description
Power Cord, SFS, 250V, 10A,
Argentina
Power Cord, 250VAC 10A 3112 Plug,
Australia
Images
Plug:
EL 219
(IRAM 2073)
2500 mm
Cordset rating: 10 A, 250/500 V MAX
Length: 8.2 ft
Connector:
EL 701
(IEC60320/C13)
Plug:
EL 210
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
EL 701C
(EN 60320/C15)
(BS 1363A) 13 AMP fuse
SFS-250V-10A-CN Power Cord, SFS, 250V, 10A, China
Plug:
EL 218
(CCEE GB2009)
Cordset rating 10A, 250V
(2500 mm)
Connector:
EL 701
(IEC60320/C13)
CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC
CAB-9K10A-EU
SFS-250V-10A-ID
SFS-250V-10A-IS
Power Cord, 250VAC 10A CEE 7/7
Plug, EU
Power Cord, SFS, 250V, 10A, India
Plug:
EL 208
Power Cord, SFS, 250V, 10A, Israel
EL-212
16A
250V
Plug:
EL 212
(SI-32)
Plug:
M2511
Cordset rating: 10A/16 A, 250 V
Length: 8 ft 2 in. (2.5 m)
Connector:
VSCC15
Cordset rating 16A, 250V
(2500mm)
Connector:
EL 701
Cordset rating 10A, 250V/500V MAX
(2500 mm)
Connector:
EL 701B
(IEC60320/C13)
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
35
CONFIGURING the SERVER
Table 15 Available Power Cords
Product ID (PID)
CAB-9K10A-IT
PID Description
Power Cord, 250VAC 10A CEI
23-16/VII Plug, Italy
Images
Plug:
I/3G
(CEI 23-16)
Cordset rating: 10 A, 250 V
Length: 8 ft 2 in. (2.5 m)
Connector
C15M
(EN60320/C15 )
CAB-9K10A-SW Power Cord, 250VAC 10A MP232
Plug, Switzerland
Plug:
MP232-R
Cordset rating: 10 A, 250 V
Length: 8 ft. 2 in (2.5 m)
Connector:
IEC 60320 C15
CAB-9K10A-UK Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
Plug:
EL 210
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
EL 701C
(EN 60320/C15)
(BS 1363A) 13 AMP fuse
CAB-9K12A-NA Power Cord, 125VAC 13A NEMA
5-15 Plug, North America
CAB-250V-10A-BR Power Cord - 250V, 10A - Brazil
CAB-JPN-3PIN Power Cord 3PIN, Japan
1
76.2 From Plug End
2,133.6 ± 25
Image not available
36 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 10 ORDER RAIL KIT AND OPTIONAL REVERSIBLE CABLE
MANAGEMENT ARM
Select a Rail Kit
Select a rail kit from
.
Table 16 Rail Kit Options
Product ID (PID)
UCSC-RAILF-M4
UCSC-RAILB-M4
PID Description
Friction Rail Kit for C220 M4 Servers
Ball Bearing Rail Kit for C220 M4 and C240 M4 Servers
Select an Optional Reversible Cable Management Arm
The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use
to order a cable management arm.
Table 17 Cable Management Arm
Product ID (PID)
UCSC-CMA1
PID Description
Cable Management Arm for C220 rack servers
For more information about the rail kit and cable management arm, see the Cisco UCS C220 M4
Installation and Service Guide at this URL:
http://www.cisco.com/c/en/US/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html
NOTE: If you plan to rackmount your UCS C220 M4 server, you must order a tool-less rail kit.
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
37
CONFIGURING the SERVER
STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL)
Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.
The TPM ordering information is listed in
Table 18 Trusted Platform Module
Product ID (PID)
UCSX-TPM2-001
PID Description
Trusted Platform Module 1.2 SPI-based for UCS Servers
NOTE: The module used in this server conforms to TPM v1.2/1.3, as defined by the
Trusted Computing Group (TCG). It is also SPI-based.
38 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL)
You can order 64 GB SD cards or 32 GB SD cards. See
for the location of the
SD cards. There are two locations, SD1 and SD2.
Table 19 64 GB Secure Digital (SD) Card (blank)
Product ID (PID)
UCS-SD-64G-S
PID Description
64 GB SD Card for UCS Servers
Table 20 32 GB Secure Digital (SD) Card (blank)
Product ID (PID)
UCS-SD-32G-S
PID Description
32 GB SD Card for UCS Servers
Caveats
■
■
Install either one or two 64 GB SD cards or one or two 32 GB SD cards
Do not mix SD card sizes
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
39
CONFIGURING the SERVER
STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE
Several operating systems and value-added software programs are available. Select as desired
Table 21 OSs and Value-Added Software (for 2-CPU servers)
PID Description Product ID (PID)
Microsoft Windows Server
MSWS-08R2-STHV Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL)
MSWS-08R2-ENHV
MSWS-08R2-DCHV2S
Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL)
Windows Svr 2008 R2-2 CPU-Data Center
MSWS-12-ST2S
MSWS-12-DC2S
MSWS-12-ST2S-NS
MSWS-12-DC2S-NS
Windows Server 2012 Standard (2 CPU/2 VMs)
Windows Server 2012 Datacenter (2 CPU/Unlimited VMs)
Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC
Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco SVC
MSWS-12R2-ST2S
MSWS-12R2-DC2S
MSWS-12R2-ST2S-NS
MSWS-12R2-DC2S-NS
SUSE
SLES-SVR-2S-1G-1A
Windows Server 2012 R2 Standard (2 CPU/2 VMs)
Windows Server 2012 R2 Datacenter (2 CPU/Unlimited VMs)
Windows Server 2012 R2 Standard (2 CPU/2 VMs) No Cisco SVC
Windows Server 2012 R2 Datacen (2 CPU/Unlim VM) No Cisco Svc
SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);1yr Support Reqd
SLES-SVR-2S-1G-3A
SLES-SVR-2S-1G-5A
SLES-SVR-2S-UG-1A
SLES-SVR-2S-UG-3A
SLES-SVR-2S-UG-5A
SLES-SHA-2S-1A
SLES-SHA-2S-3A
SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);3yr Support Reqd
SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);5yr Support Reqd
SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);1yr Support Reqd
SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);3yr Support Reqd
SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);5yr Support Reqd
SUSE Linux High Availability Ext (1-2 CPU); 1yr Support Reqd
SUSE Linux High Availability Ext (1-2 CPU); 3yr Support Reqd
SLES-SHA-2S-5A
SLES-HGC-2S-1A
SLES-HGC-2S-3A
SLES-HGC-2S-5A
SLES-SAP-2S-1G-1A
SLES-SAP-2S-1G-3A
SLES-SAP-2S-1G-5A
SLES-SAP-2S-UG-1A
SLES-SAP-2S-UG-3A
SLES-SAP-2S-UG-5A
SUSE Linux High Availability Ext (1-2 CPU); 5yr Support Reqd
SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Support Reqd
SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr Support Reqd
SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr Support Reqd
SLES for SAP Applications (1-2 CPU,1 Phys); 1yr Support Reqd
SLES for SAP Applications (1-2 CPU,1 Phys); 3yr Support Reqd
SLES for SAP Applications (1-2 CPU,1 Phys); 5yr Support Reqd
SLES for SAP Applications (1-2 CPU,Unl Vrt);1yr Support Reqd
SLES for SAP Applications (1-2 CPU,Unl Vrt);3yr Support Reqd
SLES for SAP Applications (1-2 CPU,Unl Vrt);5yr Support Reqd
40 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 21 OSs and Value-Added Software (for 2-CPU servers) (continued)
PID Description Product ID (PID)
Red Hat Enterprise Linux
RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required
RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required
RHEL-2S-4G-1A
RHEL-2S-4G-3A
RHEL/2 Socket/4 Guest/1Yr Svcs Required
RHEL/2 Socket/4 Guest/3Yr Svcs Required
RHEL-2S-UG-1A
RHEL-2S-UG-3A
RHEL-HA-2S-1A
RHEL-HA-2S-3A
RHEL-RS-2S-1A
RHEL/2 Socket/U Guest/1Yr Svcs Required
RHEL/2 Socket/U Guest/3Yr Svcs Required
RHEL Option/High-Availability/2 Socket/1Yr Svcs Required
RHEL Option/High-Availability/2 Socket/3Yr Svcs Required
RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required
RHEL-RS-2S-3A
RHEL-SFS-2S-1A
RHEL-SFS-2S-3A
RHEL Option/Resilient Storage w/ HA /2 Socket/3 Yr Svcs Reqd
RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required
RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required
BMC
BMC-012
BMC-SE-4C
BMC-SE-6C
BMC-SE-8C
BMC-SE-10C
BMC-AE-4C
BMC BPPM Per Server
BMC BladeLogic Standard Edition, 4 Cores, Support Required
BMC BladeLogic Standard Edition, 6 Cores, Support Required
BMC BladeLogic Standard Edition, 8 Cores, Support Required
BMC BladeLogic Standard Edition, 10 Cores, Support Required
BMC BladeLogic Advanced Edition, 4 Cores, Support Required
BMC-AE-6C
BMC-AE-8C
BMC BladeLogic Advanced Edition, 6 Cores, Support Required
BMC BladeLogic Advanced Edition, 8 Cores, Support Required
BMC-AE-10C BMC BladeLogic Standard Edition, 10 Cores, Support Required
Nexus 1000V for Hyper-V and vSphere
N1K-VSG-UCS-BUN Over half off N1K and VSG w/ purchase of UCS B/C Series
N1K-VLEM-UCS-1
VSG-VLEM-UCS-1
UCS Director
CUIC-PHY-SERV-BM-U
Nexus 1000V License Paper Delivery (1 CPU) for bundles
VSG License Paper Delivery (1 CPU) for bundles
CUIC-PHY-SERV-U
CUIC-TERM
Cisco Cloupia Resource Lic - One Phy Server node bare metal
Cisco Cloupia Resource Lic - One physical Server node
Acceptance of Cisco Cloupia License Terms
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
41
CONFIGURING the SERVER
Table 21 OSs and Value-Added Software (for 2-CPU servers) (continued)
PID Description
VMware 5
VMW-VS5-STD-1A
VMW-VS5-STD-2A
VMW-VS5-STD-3A
VMW-VS5-STD-4A
VMW-VS5-STD-5A
VMW-VS5-ENT-1A
VMW-VS5-ENT-2A
VMW-VS5-ENT-3A
VMW-VS5-ENT-4A
VMW-VS5-ENT-5A
VMW-VS5-ENTP-1A
VMW-VS5-ENTP-2A
VMW-VS5-ENTP-3A
VMW-VS5-ENTP-4A
VMW-VS5-ENTP-5A
VMW-VC5-STD-1A
VMW-VC5-STD-2A
VMW-VC5-STD-3A
VMW-VC5-STD-4A
VMW-VC5-STD-5A
UCS-VMW-TERMS
Product ID (PID)
VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd
VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd
VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd
VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd
VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Rqd
VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Rqd
VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Rqd
VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Rqd
VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Rqd
VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Rqd
VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Rqd
VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Rqd
VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Rqd
VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Rqd
VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Rqd
VMware vCenter 5 Server Standard, 1 yr support required
VMware vCenter 5 Server Standard, 2 yr support required
VMware vCenter 5 Server Standard, 3 yr support required
VMware vCenter 5 Server Standard, 4 yr support required
VMware vCenter 5 Server Standard, 5 yr support required
Acceptance of Terms, Standalone VMW License for UCS Servers
42 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 14 SELECT OPERATING SYSTEM MEDIA KIT
Select the optional operating system media listed in
.
Table 22 OS Media
Product ID (PID)
RHEL-6
SLES-11
MSWS-08R2-STHV-RM
MSWS-08R2-ENHV-RM
MSWS-08R2-DCHV-RM
MSWS-12-ST2S-RM
MSWS-12-DC2S-RM
MSWS-12R2-ST2S-RM
MSWS-12R2-DC2S-RM
PID Description
RHEL 6 Recovery Media Only (Multilingual)
SLES 11 media only (multilingual)
Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media
Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media
Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media
Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media
Windows Server 2012 Datacenter(2 CPU/Unlimited VM) Rec Media
Windows Server 2012 R2 Standard (2 CPU/2 VMs) Recovery Media
Windows Server 2012 R2 Datacen (2 CPU/Unlimited VM) Rec Media
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
43
CONFIGURING the SERVER
STEP 15 SELECT SERVICE and SUPPORT LEVEL
■
■
■
■
■
A variety of service options are available, as described in this section.
Unified Computing Warranty, No Contract
If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:
Three-year parts coverage.
Next business day (NBD) onsite parts replacement eight hours a day, five days a week.
90-day software warranty on media.
Ongoing downloads of BIOS, drivers, and firmware updates.
UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.
SMARTnet for UCS
For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS
Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco
Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.
For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours.
There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in
.
Table 23 Cisco SMARTnet for UCS Service
Product ID (PID) On Site? Description
CON-PREM-C220M4SF Yes
CON-OSP-C220M4SF
CON-OSE-C220M4SF
Yes
Yes
CON-OS-C220M4SF Yes
CON-S2P-C220M4SF No
CON-SNTP-C220M4SF No
CON-SNTE-C220M4SF
CON-SNT-C220M4SF
No
No
ONSITE 24X7X2 UCS C220 M4 SFF
ONSITE 24X7X4 UCS C220 M4 SFF
ONSITE 8X5X4 UCS C220 M4 SFF
ONSITE 8X5XNBD UCS C220 M4 SFF
SMARTNET 24X7X2 UCS C220 M4 SFF
SMARTNET 24X7X4 UCS C220 M4 SFF
SMARTNET 8X5X4 UCS C220 M4 SFF
SMARTNET 8X5XNBD UCS C220 M4 SFF
44 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
SMARTnet for UCS Hardware Only Service
For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a service listed in
Table 24 SMARTnet for UCS Hardware Only Service
Product ID (PID)
CON-UCW7-C220M4SF
CON-UCW5-C220M4SF
Service
Level GSP
UCW7
UCW5
On
Site?
Yes
Yes
Description
UCS HW 24X7X4OS UCS C220 M4 SFF
UC PLUS 8X5XNBDOS UCS C220 M4 SFF
Unified Computing Partner Support Service
Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:
■
■
■
Expand their service portfolios to support the most complex network environments
Lower delivery costs
Deliver services that increase customer loyalty
Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets.
This helps partners to realize higher margins and expand their practice.
PSS is available to all Cisco PSS partners, but requires additional specializations and requirements. For additional information, see the following URL:
www.cisco.com/go/partnerucssupport
The two Partner Unified Computing Support Options include:
■
■
Partner Support Service for UCS
Partner Support Service for UCS Hardware Only
Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support.
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
45
CONFIGURING the SERVER
.
Table 25 Partner Support Service for UCS
Product ID (PID)
CON-PSJ1-C220M4SF
CON-PSJ2-C220M4SF
CON-PSJ3-C220M4SF
CON-PSJ4-C220M4SF
Service
Level
GSP
PSJ1
PSJ2
PSJ3
PSJ4
On
Site?
No
No
No
No
Description
UCS SUPP PSS 8X5XNBD UCS C220 M4 SFF
UCS SUPP PSS 8X5X4 UCS C220 M4 SFF
UCS SUPP PSS 24X7X4 UCS C220 M4 SFF
UCS SUPP PSS 24X7X2 UCS C220 M4 SFF
Partner Support Service for UCS Hardware Only provides customers with replacement parts in as
.
Table 26 Partner Support Service for UCS (Hardware Only)
Product ID (PID)
CON-PSW2-C220M4SF
CON-PSW3-C220M4SF
CON-PSW4-C220M4SF
Service
Level GSP
PSW2
PSW3
PSW4
On
Site?
No
No
No
Description
UCS W PL PSS 8X5X4 UCS C220 M4 SFF
UCS W PL PSS 24X7X4 UCS C220 M4 SFF
UCS W PL PSS 24X7X2 UCS C220 M4 SFF
Unified Computing Combined Support Service
■
■
■
■
Combined Services makes it easier to purchase and manage required services under one contract. SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:
■
Optimize the uptime, performance, and efficiency of your UCS
Protect your vital business applications by rapidly identifying and addressing issues
Strengthen in-house expertise through knowledge transfer and mentoring
Improve operational efficiency by allowing UCS experts to augment your internal staff resources
Enhance business agility by diagnosing potential issues before they affect your operations
46 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
You can choose a service listed in
.
Table 27 UCS Computing Combined Support Service
Product ID (PID)
Service
Level GSP
On
Site?
Description
CON-NCF2-
C220M4SF
CON-NCF2P-
C220M4SF
NCF2
NCF2P
CON-NCF4P-
C220M4SF
NCF4P
CON-NCF4S-
C220M4SF
NCF4S
CON-NCFCS-
C220M4SF
NCFCS
CON-NCFE-
C220M4SF
NCFE
CON-NCFP-
C220M4SF
NCFP
CON-NCFT-
C220M4SF
NCFT
Yes
No
No
No
No
Yes
Yes
Yes
CMB SPT SVC 24X7X2 UCS C220 M4 SFF
CMB SPT SVC 24X7X2OS
UCS C220 M4 SFF
CMB SPT SVC 24X7X4OS
UCS C220 M4 SFF
CMB SPT SVC 8X5X4OS
UCS C220 M4 SFF
CMB SPT SVC 8X5XNBDOS
UCS C220 M4 SFF
CMB SPT SVC 8X5X4
UCS C220 M4 SFF
CMB SPT SVC 24X7X4
UCS C220 M4 SFF
CMB SPT SVC 8X5XNBD
UCS C220 M4 SFF
Unified Computing Drive Retention Service
With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.
If your company has a need to control confidential, classified, sensitive, or proprietary data, you
might want to consider one of the Drive Retention Services listed in
NOTE: Cisco does not offer a certified drive destruction service as part of this service.
Table 28 Drive Retention Service Options
Service Description
Service
Program Name
SMARTnet for UCS
Service with Drive
Retention
UCS DR
Service
Level GSP
UCSD7
UCSD5
Service Level
24x7x4 Onsite
8x5xNBD Onsite
Product ID (PID)
CON-UCSD7-C220M4SF
CON-UCSD5-C220M4SF
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
47
CONFIGURING the SERVER
Table 28 Drive Retention Service Options (continued)
Service Description
SMARTnet for UCS
HW ONLY+Drive
Retention
Service
Program Name
UCS HW+DR
Service
Level GSP
UCWD7
UCWD5
Service Level
24x7x4 Onsite
8x5xNBD Onsite
Product ID (PID)
CON-UCWD7-C220M4SF
CON-UCWD5-C220M4SF
For more service and support information, see the following URL:
http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf
For a complete listing of available services for Cisco Unified Computing System, see this URL:
http://www.cisco.com/en/US/products/ps10312/serv_group_home.html
48 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
OPTIONAL STEP - ORDER RACK(s)
OPTIONAL STEP - ORDER RACK(s)
The optional R42610 rack is available from Cisco for the C-Series servers, including the C220 M4
SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in
. Racks are shipped separately from the C220 M4 SFF server.
Table 29 Racks and Rack Options
Product ID (PID)
RACK-UCS 1
PID Description
Cisco R42610 expansion rack, no side panels
RACK-UCS2
1
RACK-BLANK-001
Cisco R42610 standard rack, w/side panels
Filler panels (qty 12), 1U, plastic, toolless
RACK-CBLMGT-001
RACK-CBLMGT-011
RACK-FASTEN-001
RACK-FASTEN-002
RACK-JOIN-001
Cable mgt D rings (qty 10), metal
Cable mgt straps (qty 10), Velcro
Mounting screws (qty 100), M6
Cage nuts (qty 50), M6
Rack joining kit
Notes . . .
1. Use these same base PIDs to order spare racks (available only as next-day replacements).
For more information about the R42610 rack, see
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
49
OPTIONAL STEP - ORDER PDU
OPTIONAL STEP - ORDER PDU
An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC220 M4 server. This PDU is available in a zero rack unit (RU) style (see
).
Table 30 PDU Options
Product ID (PID)
RP208-30-2P-U-2
PID Description
Zero RU PDU
For more information about the PDU, see
50 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
CHASSIS
Figure 6
An internal view of the C220 M4 chassis with the top cover removed is shown in
.
C220 M4 SFF With Top Cover Off
2 3
4 5
6 7 8
PSU 2
FAN 6
FAN 5
FAN 4
SD 1
CPU 2
SD 2
PSU 1
9
1
PCIe Riser 2
PCIe Riser 1
10
11
12
FAN 3
FAN 2
FAN 1
CPU 1
13
17 16 15 14
1
2
3
4
5
8
9
6
7
Drives (SAS/SATA drives are hot-swappable)
Cooling fan modules (six)
SuperCap backup unit mounting location
DIMM sockets on motherboard (24)
CPUs and heatsinks (up to two)
Embedded SATA RAID header for RAID 5 key
SD card bays on motherboard (two)
Internal USB 3.0 port on motherboard
Power supplies (up to two, hot-swappable when redundant as 1+1)
10
11
12
13
14
15
16
17
Trusted platform module (TPM) socket on motherboard (not visible in this view)
PCIe riser 2 (half-height PCIe slot 2)
PCIe riser 1 (full-height PCIe slot 1)
Modular LOM (mLOM) connector on chassis floor
Cisco modular RAID controller PCIe riser
(dedicated riser with horizontal socket)
Cisco modular RAID controller card
Embedded SATA RAID mini-SAS connectors on motherboard (not visible in this view)
RTC battery on motherboard
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
51
SUPPLEMENTAL MATERIAL
CPUs and DIMMs
Physical Layout
Each CPU has four DIMM channels:
■
■
CPU1 has channels A, B, C, and D
CPU2 has channels E, F, G, and H
Each DIMM channel has three slots: slot 1, slot 2, and slot 3. The blue-colored DIMM slots are for slot 1, the black-colored slots for slot 2, and the white slots for slot 3.
As an example, DIMM slots A1, B1, C1, and D1 belong to slot 1, while A2, B2, C2, and D2 belong to slot 2.
shows how slots and channels are physically laid out on the motherboard. The DIMM slots on the
right half of the motherboard (channels A, B, C, and D) are associated with CPU 1, while the DIMM slots on the left half of the motherboard (channels E, F, G, and H) are associated with CPU 2. The slot 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding slot 2 (black) and slot 3 (white) slots. Slot 1 slots (blue) are populated before slot 2 slots (black) and slot 3 (white) slots.
Figure 7 Physical Layout of CPU DIMM Channels and Slots
52 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Memory Population Rules
When considering the memory configuration of your server, you should consider the following items:
■
■
■
■
Each channel has three DIMM slots (for example, channel A = slots A1, A2, and A3).
— A channel can operate with one, two, or three DIMMs installed.
— If a channel has only one DIMM, populate slot 1 first (the blue slot).
When both CPUs are installed, populate the DIMM slots of each CPU identically.
— Fill blue slots in the channels first: A1, E1, B1, F1, C1, G1, D1, H1
— Fill black slots in the channels second: A2, E2, B2, F2, C2, G2, D2, H2
— Fill white slots in the channels third: A3, E3, B3, F3, C3, G3, D3, H3
Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.
Observe the DIMM mixing rules shown in
Table 31 DIMM Rules for C220 M4 Servers
DIMM Parameter DIMMs in the Same Channel
DIMM in the Same Slot 1
DIMM Capacity
RDIMM = 8 or 16 GB
LRDIMM = 32 GB
DIMM Speed
2133-MHz 2
DIMMs in the same channel (for example, A1, A2, and A3) can have different capacities.
Do not mix LRDIMMs with RDIMMs
For best performance, DIMMs in the same slot (for example, A1, B1, C1,
D1) should have the same capacity.
Do not mix LRDIMMs RDIMM s
DIMMs will run at the lowest speed of the DIMMs/CPUs installed
DIMMs will run at the lowest speed of the DIMMs/CPUs installed
DIMM Type
RDIMMs or LRDIMMs Do not mix DIMM types in a channel Do not mix DIMM types in a slot
1 DPC, 2 DPC, or 3 DPC
DIMMs per Channel (DPC)
See
valid LRDIMM and RDIMM 1 DPC, 2 DPC, and 3 DPC memory configurations
Notes . . .
1. Although you can have different DIMM capacities in the same slot, this will result in less than optimal performance. For optimal performance, all DIMMs in the same slot should be identical.
2. Only 2133-MHz DIMMs are currently available for the C220 M4 server.
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
53
SUPPLEMENTAL MATERIAL
DIMM Population Order
Populate the DIMMs for a CPU according to
Table 32 DIMM Population Order per CPU
Populate
CPU 2 Slots
E1
E1, F1
E1, F1, G1
E1, F1, G1, H1
E1, F1, G1,
E2, F2, G2
E1, F1, G1, H1,
E2, F2, G2, H2
E1, F1, G1, H1,
E2, F2, G2, H2,
E3, F3, G3, H3
54 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Recommended Memory Configuration
This section explains the recommended DIMM population order rules for the C220 M4 server.
■
■
■
■
All DIMMs must be DDR4 DIMMs.
Do not mix:
— DIMMs with different clock rates in a channel
— RDIMMs and LRDIMMs
— ECC and non-ECC DIMMs
There are blue, black, and white DIMM slots. Populate blue slots first.
When DIMMs ranks are mixed in the same channel, always populate the highest rank DIMM in the blue DIMM slot and lower rank DIMM(s) in the black and white DIMM slots.
Many memory configurations are possible. For best results, follow
DIMMs for Intel Xeon E5-2600 v3 CPUs.
Table 33 Recommended Memory Configurations for Intel Xeon E5-2600 v3 CPUs (with 2133-MHz DIMMs)
1
Total
System
Memory
Size
Blue Slots
Slot 1
(A1,B1,
C1,D1)
CPU 1 DIMMs
Black Slots
Slot 2
(A2,B2,
C2,D2)
White Slots
Slot 3
(A3,B3,
C3,D3)
Blue Slots
Slot 1
(E1,F1,
G1,H1)
CPU 2 DIMMs
Black Slots
Slot 2
(E2,F2,
G2,H2)
White Slots
Slot 3
(E3,F3,
G3,H3)
DIMM Max
Speed
(MHz)
64 GB
4x8 GB — — 4x8 GB — — 2133
Total
DIMMs
8
128 GB
192 GB
256 GB
512 GB
768 GB
4x8 GB
4x16 GB
1x32 GB
4x16 GB
3x32 GB
4x16 GB
4x32 GB
4x32 GB
4x32 GB
4x8 GB
—
1x32 GB
4x8 GB
—
4x16 GB
—
4x32 GB
4x32 GB
—
—
—
—
—
—
—
—
4x32 GB
4x8 GB
4x16 GB
1x32 GB
4x16 GB
3x32 GB
4x16 GB
4x32 GB
4x32 GB
4x32 GB
4x8 GB
—
1x32 GB
4x8 GB
—
4x16 GB
—
4x32 GB
4x32 GB
—
—
—
—
—
—
—
—
4x32 GB
2133
2133
2133
1866
2133
2133
2133
2133
1866
4
16
6
16
16
8
8
16
24
Notes . . .
1. Rows marked in yellow indicate best performance.
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
55
SUPPLEMENTAL MATERIAL
Additional DIMM Populations
is not a complete list of all supported DIMM populations, but highlights common
configuration options.
1 x 8 GB
2 x 8 GB
1 x 16 GB
4 x 8 GB
2 x 16 GB
1 x 32 GB
8 x 8 GB
4 x 16 GB
2 x 32 GB
12 x 8 GB
6 x 16 GB
8 x 16 GB
4 x 32 GB
12 x 16 GB
6 x 32 GB
8 x 32 GB
12 x 32 GB
Table 34 Supported DIMM Configurations
CPU 1 DIMMs
Total DIMMs for CPU 1
CPU 1
Capacity
CPU 2 DIMMs
6
8
4
12
12
6
8
2
12
8
4
2
1
1
4
1
2
8 GB
16 GB
16 GB
32 GB
32 GB
32 GB
64 GB
64 GB
1 x 8 GB
2 x 8 GB
1 x 16 GB
4 x 8 GB
2 x 16 GB
1 x 32 GB
8 x 8 GB
4 x 16 GB
64 GB
96 GB
2 x 32 GB
12 x 8 GB
96 GB 6 x 16 GB
128 GB 8 x 16 GB
128 GB 4 x 32 GB
192 GB 12 x 16 GB
192 GB 6 x 32 GB
256 GB 8 x 32 GB
384 GB 12 x 32 GB
Total DIMMs for CPU 2
CPU 2
Capacity
6
8
4
12
12
6
8
2
12
8
4
2
1
1
4
1
2
8 GB
16 GB
16 GB
32 GB
32 GB
32 GB
64 GB
64 GB
64 GB
96 GB
96 GB
128 GB
128 GB
192 GB
192 GB
256 GB
384 GB
Total
Capacity for
2 CPUs
128 GB
192 GB
192 GB
256 GB
256 GB
384 GB
384 GB
512 GB
768 GB
16 GB
32 GB
32 GB
64 GB
64 GB
64 GB
128 GB
128 GB
56 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
RAID Details
The available RAID configurations are shown in this section.
(1) 1- and 2-CPU Configurations
Select one of these:
— The embedded software RAID 5 key upgrade option from
, or
— One Cisco 12G SAS Modular RAID controller from
— One Cisco 9300-8E 12G SAS RAID controller from
— One Cisco 12G SAS Modular RAID controller from
9300-8E 12G SAS RAID controller from
Select an appropriate optional RAID configuration listed in
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
57
SUPPLEMENTAL MATERIAL
RAID Option ROM (OPROM) Settings
The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option
ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in
.
Figure 8 Example BIOS Screen for OPROM
58 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Embedded SATA RAID: Two SATA Controllers
The embedded SATA RAID controller hub is split into two controllers, SATA and sSATA (secondary SATA).
These two controllers are seen as separate RAID controllers in the Cisco IMC interface and are configurable separately.
■
■
The first SATA controller controls drives 1–4; the secondary sSATA controller controls drives 5–8.
When configuring RAID groups, you cannot create a group that spans more than four drives.
■
The first SATA controller can control a RAID group of up to four drives, consisting only of drives 1–4.
■
The secondary sSATA controller can control a RAID group of up to four drives, consisting only of drives 5–8. See
.
Figure 9 Embedded RAID Controller RAID Groups
HDD 01
HDD 04
HDD 02
HDD 05
HDD 03
HDD 06 HDD 07 HDD 08
SATA RAID Controller Hub
SATA sSATA
■
Each controller is listed separately in the BIOS. You can select the boot order of the controllers in the BIOS (use the Boot Options tab in the BIOS Setup Utility).
Note the following considerations:
■
■
■
■
The default setting for this embedded controller hub is SATA RAID 0, 1, and 10 support for up to eight SATA drives (in two groups of four drives).
You can upgrade this to support to SATA RAID 0, 1, 5, and 10 support for up to eight SATA drives (in two groups of four drives) by installing a RAID 5 key module on the motherboard.
When you order the server with this embedded controller, the controller is enabled in the BIOS.
You cannot downgrade from using a HW RAID controller card to using the SW RAID embedded controller.
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
59
SUPPLEMENTAL MATERIAL
To Create a RAID Group
(1) While the server is booting, wait for the prompt and press function key F2 as shown in
.
Figure 10 Function Key F2 Prompt
In a few seconds, you will see the screen that allows you to set up a RAID group for the primary
SATA controller (see
Figure 11 Screen to Configure Primary SATA RAID Group
60 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
(2) Press Ctrl+M to start the RAID group creation process for the primary SATA controller (for drives 1-4, as shown in
). Or, do nothing and wait for the next screen, which allows you to create a RAID group for the secondary SATA (sSATA) controller see
).
Figure 12 Screen to Configure Secondary SATA (sSATA) RAID Group
(3) Press Ctrl+M to start the RAID group creation process for the secondary SATA (sSATA) controller (for drives 5-8, as shown in
).
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
61
SUPPLEMENTAL MATERIAL
Serial Port Details
The pinout details of the rear RJ-45 serial port connector are shown in
.
Figure 13 Serial Port (Female RJ-45 Connector) Pinout
Serial Port (RJ-45 Female Connector)
Pin Signal
6
7
4
5
8
1
2
3
RTS (Request to Send)
DTR (Data Terminal Ready)
TxD (Transmit Data)
GND (Signal Ground)
GND (Signal Ground)
RxD (Receive Data)
DSR (Data Set Ready)
CTS (Clear to Send)
62 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Upgrade and Servicing-Related Parts
This section lists the upgrade and servicing-related parts you may need during the life of your server. Some of these parts are configured with every server, and some may be ordered when needed or may be ordered and kept on hand as spares for future use. See
.Drive Blanking Panels
Table 35 Upgrade and Servicing-related Parts for UCS C220 M4 LFF Server
Spare Product ID (PID)
UCSC-HS-C220M4=
UCS-CPU-GREASE3=
UCS-CPU-LPCVR=
UCSX-HSCK=
UCSC-PCI-2A-220M4=
UCSC-PCI-2C-220M4=
UCSC-PCIF-01H=
UCSC-PCIF-01F=
N20-BBLKD
UCSC-MLOM-BLK=
UCSC-RAILF-M4=
UCSC-CMAF-M4=
UCSC-RAILB-M4=
UCSC-FAN-C220M4=
UCSC-BAFF-C220M4=
N20-BKVM=
UCSC-PSU-BLKP1U=
UCS-220CBLSR8=
UCS-220CBLMR8=
Description
Heat sink for UCS C220 M4 rack servers
M4 Server CPU thermal grease syringe - needed for heatsink seal
CPU load plate dust cover (for unpopulated CPU sockets)
UCS Processor Heat Sink Cleaning Kit For Replacement of CPU
C220 M4 PCIe Riser 1&2 Assy
C220 M4 PCIe Riser 3 (HBA)
PCIe Low Profile blanking panel for UCS C-Series Server
PCIe Full Height blanking panel for UCS C-Series Server
HDD blanking panel 1
MLOM blanking panel
Friction Rail Kit for C220 M4 rack servers
Reversible CMA for C220 M4 friction & ball bearing rail kits
Ball Bearing Rail Kit for C220 M4 and C220 M4 rack servers
C220 M4 Fan Module (one)
C220 M4 Air Baffle, Plastic Kit
KVM cable for Server console port
Power Supply Blanking Panel for C220 M4 servers
C220 M4 set of 2 SATA/SW RAID cables for 8HDD bckpln chassis
C220 M4 set of 2 RAID cntrlr cables for 8HDD bckpln chassis
Notes . . .
1. A drive blanking panel must be installed if you remove a disk drive from a UCS server. These panels are required to maintain system temperatures at safe operating levels, and to keep dust away from system components.
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
63
SUPPLEMENTAL MATERIAL
Adding an Additional CPU (with CPU heat sink)
All Cisco UCS two CPU socket-capable servers can be upgraded from having one to having two CPUs configured. You will need to order and install a heat sink when adding any additional CPU to a server.
Instructions for installing the new CPU and heat sink can be found at the following link:
http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html
See the section titled “Replacing CPUs and Heatsinks.”
Motherboard Lithium Battery
You can order a replacement motherboard battery. Installation instructions are found at this link:
http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html
See the section titled “Replacing the Motherboard RTC Battery.”
Thermal Grease (with syringe applicator) for CPU to Heatsink Seal
Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink.
Instructions for applying thermal grease are found at:
http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html
See the section titled “Replacing CPUs and Heatsinks.”
CAUTION: Use only the thermal grease specified for this server
(UCS-CPU-GREASE3=). This thermal grease comes in a white-tipped syringe and is to be used only in the C220 M4 and C240 M4 servers. Other servers use thermal grease in a blue-tipped syringe (UCS-CPU-GREASE=).
Thermal grease for other systems may have different thermal conductivity properties and may cause overheating if used in the C220 M4 or C240 M4 servers.
DO NOT use thermal grease available for purchase at any commercial electronics store. If these instructions are not followed, the CPU may overheat and be destroyed.
NOTE: When you purchase a spare CPU, the thermal grease with syringe applicator is included.
64 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Air Baffle Replacement Kit
Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level. These baffles must always remain installed during server operation. The Air Baffle
Replacement Kit includes the air baffles needed for one UCS C220 M4 server.
CPU Heat Sink Cleaning Kit
The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process. Instructions for cleaning are found at the following link:
http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html
See the section titled “Replacing CPUs and Heatsinks.”
NOTE: When you purchase a spare CPU, the CPU cleaning kit is included.
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
65
SUPPLEMENTAL MATERIAL
RACKS
The Cisco R42610 rack (see
) is certified for Cisco UCS installation at customer sites and is
suitable for the following equipment:
■
■
Cisco UCS B-Series servers and fabric interconnects
Cisco UCS C-Series and select Nexus switches
The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are
Table 36 Cisco R42610 Rack Specifications
Parameter
Dimensions (H x W x D)
Dimensions (H x W x D) with packaging
Distance from front mounting rail to rear mounting rail
Weight
Weight with packaging
Side panels included
Equipment mounting capacity
Static load capacity
Standard Rack
78.74 x 24 x 43.38 in.
(2000 x 610 x 1102 mm)
89 x 33 x 47 in.
(2261 x 838 x 1194 mm)
29.2 in (741 mm)
299.83 lb (136 kg)
354 lb
(161 kg)
Yes
42RU
Dynamic load capacity
2100 lb
(954 kg)
Not applicable
Expansion Rack
78.74 x 23.58 x 43.38 in.
(2000 x 599 x 1102 mm)
89 x 33 x 47 in.
(2261 x 838 x 1194 mm)
29.2 in (741 mm)
231. 49 lb (105 kg)
284 lb
(129 kg)
No
42RU
2100 lb
(954 kg)
Not applicable
NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet.
66 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
Figure 14 Cisco R42610 Rack
SUPPLEMENTAL MATERIAL
Front view - door
Front view - door open
Front view - door removed
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
67
SUPPLEMENTAL MATERIAL
PDUs
Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection.
Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician.
With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
The C-series severs accept the zero-rack-unit (0RU) PDU. See
Figure 15 Zero Rack Unit PDU (PID = RP208-30-2P-U-2)
1
2
Breakers
Ground connection
3
4
C19 plugs
C13 plugs
Cisco RP Series PDU models provide two 20-ampere (A) circuit breakers for groups of receptacles. The effects of a tripped circuit are limited to a receptacle group. Simply press a button to reset that circuit.
68 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
KVM CABLE
The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server.
The KVM cable ordering information is listed in
.
Table 37 KVM Cable
Product ID (PID)
N20-BKVM=
PID Description
KVM cable for B-Series Blade Server console port
Figure 16 KVM Cable
1
2
Connector (to server front panel)
DB-9 serial connector
3
4
VGA connector (for a monitor)
Two-port USB connector (for a mouse and keyboard)
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
69
SUPPLEMENTAL MATERIAL
Motherboard USB and SD Ports, and RAID Card Backup Location
The C220 M4 SFF motherboard has a general-purpose USB socket, and two SD sockets as shown in
The mounting location for the RAID SuperCap data cache power backup module is also shown.
Figure 17 Motherboard USB and SD Ports and RAID Card SuperCap Location
2 3
4 5 6 7 8
PSU 2
FAN 6
FAN 5
FAN 4
SD 1
CPU 2
SD 2
PSU 1
9
1
PCIe Riser 2
PCIe Riser 1
10
11
12
FAN 3
FAN 2
FAN 1
CPU 1
13
17
1
2
3
4
5
8
9
6
7
Drives (SAS/SATA drives are hot-swappable)
Cooling fan modules (six)
SuperCap Power Module (RAID backup) mounting bracket
DIMM sockets on motherboard (24)
CPUs and heatsinks (up to two)
Embedded SATA RAID header for RAID 5 key
SD card bays on motherboard (two)
Internal USB 3.0 port on motherboard
Power supplies (up to two, hot-swappable when redundant as 1+1)
16 15 14
10
11
12
13
14
15
16
17
Trusted platform module (TPM) socket on motherboard (not visible in this view)
PCIe riser 2 (half-height PCIe slot 2)
PCIe riser 1 (full-height PCIe slot 1)
Modular LOM (mLOM) connector on chassis floor
Cisco modular RAID controller PCIe riser
(dedicated riser with horizontal socket)
Cisco modular RAID controller card
Embedded SATA RAID mini-SAS connectors on motherboard (not visible in this view)
RTC battery on motherboard
70 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Table 38 UCS C220 M4 Dimensions and Weight
Parameter
Height
Width
Depth
Front Clearance
Side Clearance
Rear Clearance
Weight
Maximum (8 HDDs, 2 CPUs, 16 DIMMs, 2 770 W power supplies)
Minimum (1 HDD, 1 CPU, 1 DIMM, 1 770 W power supply)
Bare (0 HDD, 0 CPU, 0 DIMM, 1 770 W power supply)
Value
1.7 in. (4.32 cm)
16.89 in. (43.0 cm) including handles:
18.98 in. (48.2 cm)
29.8 in. (75.6 cm) including handles:
30.98 in. (78.7 cm)
3 in. (76 mm)
1 in. (25 mm)
6 in. (152 mm)
37.9 lbs (17.2 kg)
30.5 lbs (13.8 kg)
29.2 lbs (13.2 kg)
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
71
TECHNICAL SPECIFICATIONS
Power Specifications
The general power specifications for the C220 M4 SFF server 770 W (AC) power supply are listed in
Table 39 UCS C220 M4 SFF 770 W Power Supply Specifications
Description
AC input voltage
AC input frequency
Maximum AC input current
Maximum AC inrush current
Maximum output power for each power supply
Power supply output voltage
Power supply efficiency
Specification
100—240 VAC (nominal input voltage range)
90—64 VAC (min/max input voltage range)
47 to 63 Hz (single phase)
9.5 Amps maximum at 100 VAC
4.5 Amps maximum at 208 VAC
15 Amps peak at +35 degree C, 208V
(charging current for EMI-X capacitors is not considered to be inrush current)
For 90—264 VAC input range, the maximum rated output power is 770 watts per power supply
12 VDC ± 5%
CSCI Platinum, 230 VAC at 50 Hz:
Greater than:
■
90% at 20% load
■
94% at 50% load
■
91% at 100% load
In addition, 208 VAC at 60 Hz efficiency shall be greater than:
■
■
■
89% at 20% load
93% at 50% load
90% at 100% load
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
72 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Environmental Specifications
The power specifications for the C220 M4 server are listed in
Table 40 UCS C220 M4 SFF Environmental Specifications
Parameter
Temperature operating
Temperature nonoperating
Humidity (RH) operating
Humidity (RH) nonoperating
Altitude operating
Altitude nonoperating
Sound Power level, Measure
A-weighted per ISO7779 LWAd (Bels)
Operation at 73°F (23°C)
Sound Pressure level, Measure
A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
Minimum
41 to 95° F (5 to 35° C) derate the maximum temperature by 1°C per every
1000 ft. (305 m) of altitude above sea level
–40 to 149°F (–40 to 65° C)
10 to 90%, non-condensing at 82° F (28° C)
5 to 93% at 82° F (28° C)
0 to 3,000 m (0 to 10,000 ft.)
0 to 12,192 m (0 to 40,000 ft.)
5.4
37
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
73
TECHNICAL SPECIFICATIONS
Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in
.
Table 41 UCS C-Series Regulatory Compliance Requirements
Parameter
Regulatory Compliance
Safety
EMC - Emissions
EMC - Immunity
Description
Products should comply with CE Markings per directives
2004/108/EC and 2006/95/EC
UL 60950-1 Second Edition
CAN/CSA-C22.2 No. 60950-1 Second Edition
EN 60950-1 Second Edition
IEC 60950-1 Second Edition
AS/NZS 60950-1
GB4943 2001
47CFR Part 15 (CFR 47) Class A
AS/NZS CISPR22 Class A
CISPR22 Class A
EN55022 Class A
ICES003 Class A
VCCI Class A
EN61000-3-2
EN61000-3-3
KN22 Class A
CNS13438 Class A
EN55024
CISPR24
EN300386
KN24
74 Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 OVERVIEW
- 4 DETAILED VIEWS
- 4 Chassis Front View
- 5 Chassis Rear View
- 6 BASE SERVER STANDARD CAPABILITIES and FEATURES
- 9 CONFIGURING the SERVER
- 49 OPTIONAL STEP - ORDER RACK(s)
- 50 OPTIONAL STEP - ORDER PDU
- 51 SUPPLEMENTAL MATERIAL
- 51 CHASSIS
- 52 CPUs and DIMMs
- 52 Physical Layout
- 53 Memory Population Rules
- 54 DIMM Population Order
- 55 Recommended Memory Configuration
- 56 Additional DIMM Populations
- 57 RAID Details
- 58 RAID Option ROM (OPROM) Settings
- 59 Embedded SATA RAID: Two SATA Controllers
- 62 Serial Port Details
- 63 Upgrade and Servicing-Related Parts
- 64 Adding an Additional CPU (with CPU heat sink)
- 64 Motherboard Lithium Battery
- 64 Thermal Grease (with syringe applicator) for CPU to Heatsink Seal
- 65 Air Baffle Replacement Kit
- 65 CPU Heat Sink Cleaning Kit
- 66 RACKS
- 68 PDUs
- 69 KVM CABLE
- 70 Motherboard USB and SD Ports, and RAID Card Backup Location
- 71 TECHNICAL SPECIFICATIONS
- 71 Dimensions and Weight
- 72 Power Specifications
- 73 Environmental Specifications
- 74 Compliance Requirements